Upload
others
View
4
Download
0
Embed Size (px)
Citation preview
TRINITY ERD
EVALUATION REPORT
CertainTeed Corporation20 Moores Road
Malvern, PA 19355
(610) 651-5847
Scope:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use ofconstruction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated forcompliance with the 6th Edition (2017) Florida Building Code sections noted herein.
Description: Flintlastic® Modified Bitumen Roof Systems
Labeling: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency notedherein.
Continued Compliance: This Evaluation Report is valid until such time as the named product(s) changes, the referencedQuality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance ofthis Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the productchanges or the referenced Quality Assurance documentation changes. Trinity | ERD requires a complete review of thisEvaluation Report relative to updated Code requirements with each Code Cycle.
Advertisement: The Evaluation Report number preceded by the words 'Trinity | ERD Evaluated" may be displayed inadvertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
Inspection: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer orits distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6, plus a 57-page Appendix.
Prepared by:
Robert J.M. Nieminen, P.E.Florida Registration No. 59166, Florida DCA ANE1983 . -„-i•„•>.•
Certification of Independence:
1. Exterior Research & Design, LLC. d/b/a Trinity | ERD does not have, nor does it intend to acquire or will it acquire, a financial interestin any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity | ERD is not owned, operated or controlled by any company manufacturing ordistributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products forwhich the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of theproduct.
5. This is a building code evaluation. Neither Trinity| ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for anyproject on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retainedspecifically for that purpose.
"v<i
'2 Of.fi!.
EXTERIOR RESEARCH & DESIGN, LLC.Certificate ofAuthorization #9503
353 Christian Street
Oxford, CT 06478
(203) 262-9245
Evaluation Report 3520.03.04-R20FL2533-R19
Date of Issuance: 09/19/2005Revision 20:09/14/2017
The facsimile seal appearing was authorized by Robert Nieminen,
P.E.on 09/14/2017. This does not serve as an electronically signeddocument.
TRINITY ERD
Roofing Systems Evaluation:
Scope:
Product Category: RoofingSub-Category: Modified Bitumen Roof SystemsCompliance Statement: Flintlastic0 Modified Bitumen Roof Systems, as produced by CertainTeed Corporation,have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code throughtesting in accordance with the following Standards. Compliance is subject to the Installation Requirements andLimitations / Conditions of Use set forth herein.
Standards:
Section
1504.3.1
1504.7
1507.11.2
1507.11.2
1507.11.2
1507.11.2
1507.11.2
References:
Entity
ERD (TST6049)
ERD (TST6049)
ERD(TST6049)
ERD (TST6049)
ERD (TST6049)
ERD(TST6049)ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)ERD(TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)ERD (TST6049)
ERD (TST6049)
ERD (TST6049)ERD (TST6049)
ERD (TST6049)
ERD (TST6049)ERD (TST6049)
ERD(TST6049)
ERD (TST6049)
ERD (TST6049)ERD (TST6049)ERD(TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)ERD (TST6049)
ERD (TST6049)
ERD (TST6049)ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
Exterior Research and Design, LLC.Certificate ofAuthorization U9S03
Property
Wind
Impact
Physical PropertiesPhysical PropertiesPhysical PropertiesPhysical PropertiesPhysical Properties
Examination
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470/4474
FM 4470/4474FM 4470/4474
FM 4470/4474Physical PropertiesFM 4470/4474FM 4470/4474FM 4470/4474Physical PropertiesPhysical PropertiesFM 4470/4474FM 4470/4474
FM 4470/4474FM 4470/4474FM 4470/4474
FM 4470/4474
FM 4470/4474TAS117(B), RuptureFM 4470/4474
FM 4470/4474Physical PropertiesFM 4470/4474FM 4470/4474TAS 117(A)
FM 4470/4474
FM 4470/4474FM 4470/4474
FM 4470/4474FM 4470/4474
FM 4470/4474FM 4470/4474
FM4470
FM 4470/4474FM 4470/4474
Standard
FM 4474
FM 4470
ASTM D6162
ASTM D6163
ASTM D6164
ASTM D6222
ASTM D6509
Reference
3S04.06.01-1
3513.08.02
03515.07.03
3519.12.03
3522.07.04
02843.02.05-11
3533.01.06
4674.11.01-1
3535.10.06
3521.07.04-R1
02764.09.05-R1
02762.03.0S-R1
C7290.01.08
C10080.09.08
C8370.08.08-R1
P6860.06.07-R1
C30310.12.09
C30560.03.10
C31420.08.10
C33980.12.10
C33830.02.ll
C35500.02.ll
C37820.07.12
C37830.07.12
C42110.08.12
C39670.08.12
C42280.08.12
A35880.04.12-R1
C44580.07.13
C46090.ll.13-A
C45620.03.14
C46760.06.14
C47320.03.14-R1
CTR-SC899S.10.15
CTR-SC9935.01.16
CTR-SC9920.01.16-R1
CTR-SC10420.01.16
CTR-SC9175.09.16-1
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic*Modified Bitumen RoofSystems; (610) 651-5847
Year
2011
2012
2008
2008
2011
2011
2009
Date
06/05/200108/15/2002
07/22/200312/22/200307/28/2004
02/10/200501/06/2006
03/21/200610/31/2006
10/26/200712/10/200712/10/2007
01/16/200809/04/200810/05/2009
09/10/2009
12/17/200903/18/2010
09/21/2010
12/22/2010
02/08/201102/09/2011
07/24/201207/26/201208/13/2012
08/20/2012
08/20/201210/26/2012
07/25/201311/20/201303/27/201406/19/201404/01/201510/14/201501/14/201601/20/2016
01/25/201609/06/2016
Evaluation Report 3520.03.04-R20FL2533-R19
Revision 20:09/14/2017Page 2 of 6
Entity
ERD(TST6049)ERD (TST6049)ERD (TST6049)ERD (TST6049)
FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)MTI (TST2508)
MTI (TST2508)MTI (TST2508)MTI (TST2508)MTI (TST2508)MTI (TST2508)MTI (TST2508)PRI (TST5878)PRI(TST5878)PRI (TST5878)PRI (TST5878)PRI (TST5878)PRI (TST5878)PRI (TST5878)PRI (TST5878)PRI (TST5878)PRI (TST5878)PRI (TST5878)UL, LLC. (QUA9625)
Exterior Research and Design, LLC.Certificate ofAuthorization #9503
Examination
FM 4470/4474
FM 4470/4474FM 4470/4474FM 4474
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470/4474FM 4470/4474
FM 4470/4474FM 4470/4474FM 4470/4474
FM 4470/4474FM 4470/4474FM 4470/4474FM 4470/4474FM 4470/4474
FM 4470/4474FM 4470/4474FM 4470/4474FM 4470/4474FM 4470/4474FM 4470/4474Physical propertiesPhysical propertiesPhysical propertiesPhysical propertiesPhysical propertiesPhysical propertiesPhysical propertiesPhysical PropertiesPhysical PropertiesPhysical PropertiesPhysical PropertiesPhysical Properties
Physical PropertiesPhysical PropertiesPhysical PropertiesPhysical PropertiesPhysical PropertiesPhysical Properties
Quality Assurance
Reference
CTR-SC9175.09.16-1
CTR-SC11590.08.16-R1
CTR-SC12255.12.16
CRT-SC15775.17
0E3A2.AM
3W0A4.AM
3W0A2.AM
3W0A3.AM
1Z4A6.AM
3Y8A1.AM
2D5A9.AM
3009502
3008869
3009610
3006025
3012321
3009814
3014502
3015444
3014692
3014751
3018579
3020703
3021759
3022038
3023458
3026128
3024311
3025766
3028410
3026964
3031262
3031199
3032172
3037127
3039848
3046104
3048520
DX08C4A
DX20E3A
DX20E3A-001
AX31G8A
AX31G8D
AX31G8F
AX21G8C
CTC-032-02-01
CTC-034-02-01
CTC-066-02-01
CTC-067-02-01
CTC-068-02-01
CTC-070-02-01
CTC-071-02-01
CTC-093-02-01
CTC-116-02-01
CTC-183-02-01
CTC-259-02-01
Service Confirmation, R11656
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
TRINITY ERD
Date
09/06/201609/06/201612/27/201609/13/201703/30/198203/16/199303/17/199303/17/199309/11/199609/30/199606/22/199912/12/200003/19/200110/15/200112/28/200107/29/200209/06/2002
04/04/200307/11/200308/05/200308/27/200310/09/200307/30/200406/03/200504/05/200607/18/200608/04/200611/01/200611/13/200602/19/200707/25/200711/30/200712/23/200806/12/200901/11/201012/02/201108/13/201309/19/201303/22/200403/22/200401/04/200608/21/200809/05/2008
06/05/200901/28/201101/16/200811/24/200808/08/201108/08/201108/08/201108/08/201108/08/201108/08/201104/03/2012
10/04/201312/11/2015Exp. 03/09/2020
Evaluation Report 3520.03.04-R20
FL2533-R19
Revision 20:09/14/2017Page 3 of 6
TRINITY ERD
Product Description:
This Evaluation Report covers Flintlastic® Modified Bitumen RoofSystems installed in accordance with CertainTeedCorporation published installation instructions and the Limitations / Conditions of Use herein. The followingCertainTeed products make up the subject systems.
Table 1: Roll-Goods for Flintlastic* Modified Bitumen Roof Systems
Type ProductSpecification
Reference Grade Type
Base Sheets
Flintlastic® SANailBase ASTM D4601 N/A II
Glasbase™ Base Sheet ASTM D4601 N/A II
All Weather/Empire™ Base ASTM D4601 N/A II
Flexiglas™ Base ASTM D4601 N/A II
Flintlastic™ Base 20 ASTM D4601 N/A II
Flintlastic Poly SMS Base Sheet ASTM D4601 N/A II
Yosemite® Venting Base ASTM D4897 N/A II
Ply SheetsFlintglas® Ply 4 ASTM D2178 N/A IV
Flintglas® Premium Ply 6 ASTM D2178 N/A VI
Base/Ply Membranes (APP)Flintlastic* APP Base T ASTM D6509 N/A N/AFlintlastic* STA ASTM D6222 S 1
Flintlastic* STA Plus ASTM D6222 S 1
Cap Membranes (APP)
Flintlastic* STA ASTM D6222 S 1
Flintlastic* STA Plus ASTM D6222 S 1
Flintlastic* GTA ASTM D6222 G 1
Flintlastic® GTA CoolStar™ ASTM D6222 G 1
Flintlastic* GTA-FR ASTM D6222 G 1
Flintlastic* GTA-FR CoolStar™ ASTM D6222 G 1
Base/Ply Membranes (SBS)
Flintlastic" SA PlyBase ASTM D1970 N/A N/ABlack Diamond® Base Sheet ASTM D1970 N/A N/AFlintlastic" SA Mid Ply ASTM D6163 S 1
Flintlastic* Ultra Glass SA ASTM D6163 S 1
Flintlastic* Base 20 ASTM D6163 S 1
Flintlastic" Base 20 T ASTM D6163 S 1
Flintlastic" Ultra Poly SMS Base Sheet ASTM D6164 S 1
Cap Membranes (SBS)
Flintlastic* FR Dual Cap ASTM D6162 G 1
Flintlastic" SA Cap FR ASTM D6163 G 1
Flintlastic" SA Cap FR CoolStar'" ASTM D6163 G 1
Flintlastic" Cap 30 ASTM D6163 G 1
Flintlastic" Cap 30 CoolStar™ ASTM D6163 G 1
Flintlastic" FR Cap 30 ASTM D6163 G 1
Flintlastic" FR Cap30 CoolStar™ ASTM D6163 G 1
Flintlastic" FR Cap 30T ASTM D6163 G 1
Flintlastic" FR Cap 30TCoolStar™ ASTM D6163 G 1
Flintlastic" SA Cap ASTM D6164 G 1
Flintlastic" SA Cap CoolStar™ ASTM D6164 G 1
Flintlastic" FR-P ASTM D6164 G 1
Flintlastic" FR-P CoolStar™ ASTM D6164 G 1
Flintlastic" GMS ASTM D6164 G 1
Flintlastic" GMS CoolStar™ ASTM D6164 G 1
Flintlastic" GTS ASTM D6164 G II
Flintlastic" GTS CoolStar™ ASTM D6164 G II
Flintlastic" GTS-FR ASTM D6164 G II
Flintlastic" GTS-FR CoolStar™ ASTM D6164 G II
Flintlastic" Premium FR-P ASTM D6164 G II
Flintlastic"Premium FR-P CoolStar™ ASTM D6164 G II
Exterior Research and Design, LLC.Certificate ofAuthorization #9503 6™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen RoofSystems; (610)651-5847
Evaluation Report 3520.03.04-R20FL2533-R19
Revision 20:09/14/2017
Page 4 of 6
TRINITY ERD
LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity | ERD nor Robert Nieminen, P.E. are, in any way, theDesigner of Record for any project on which this Evaluation Report, or previous versions thereof, is/was usedfor permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in HVHZjurisdictions.
5.3 Refer to a current UL Roofing Materials Directory for fire ratings of this product.
5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordancewith FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply.
5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structuralmembers shall be in accordance with FBC requirements to the satisfaction of the Authority HavingJurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBCApproval documentation.
5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511.
5.7 For mechanically attached insulation or membrane or strip-bonded insulation, the maximum design pressurefor the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance withFBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified designprofessional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM LossPrevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM LossPrevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selectedassembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. Norational analysis is permitted for these systems.
5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in theexisting deck for withdrawal resistance. A qualified design professional shall review the data for comparisonto the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRIFX-1 or Testing Application Standard TAS 105.
5.10 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, theexisting deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. Ifany surface conditions exist that bring system performance into question, field uplift testing in accordancewith ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS124 shall be conducted on mock-ups of the proposed new roof assembly.
5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roofsystem shall be capable of resisting project design pressures on its own merit to the satisfaction of theAuthority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FMLoss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance withFBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application StandardRAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or1609.3(3).
5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3.
Exterior Research and Design, LLC. Evaluation Report 3520.03.04-R20Certificate ofAuthorization #9503 6thEDITION (2017) FBC NON-HVHZ EVALUATION FL2533-R19
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847 Revision 20:09/14/2017Page 5 of 6
TRINITY ERD
Installation:
6.1 Flintlastic® Modified Bitumen Roof Systems shall be installed in accordance with CertainTeed Corporationpublished installation instructions, subject to the Limitations / Conditions of Useherein.
6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = MaximumDesign Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflectsthe ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already beenapplied). Referto FBC 1609 for determination of design wind loads.
Building Permit Requirements:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation ofthis product.
Manufacturing Plants:
Contact the named QA entityfor manufacturing facilities covered byF.A.C. Rule 61G20-3 QA requirements.
Quality Assurance Entity:
UL, LLC. - QUA9625; (414) 248-6409, [email protected]
- THE57-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 3520.03.04-R20Certificate ofAuthorization #9503 6™ EDITION (2017) FBC NON-HVHZ EVALUATION FL2533-R19
CertainTeed Flintlastic* Modified BitumenRoofSystems;(610) 651-5847 Revision 20:09/14/2017Page 6 of 6
Appendix 1: Attachment Requirements for Wind Upuft Resistance
Table Deck Application
1A Wood New or Reroof (Tear-Off)
IB Wood New, Reroof (Tear-Off) or Recover
1C Wood New, Reroof (Tear-Off) or Recover
ID Wood New, Reroof (Tear-Off) or Recover
1E-1 Wood New, Reroof (Tear-Off)
1E-2 Wood New, Reroof (Tear-Off) or Recover
IF Wood New or Reroof (Tear-Off)
2A Steel or Structural Concrete New, Reroof (Tear-Off) or Recover
2B Steel or Structural Concrete New, Reroof (Tear-Off) or Recover
2C Steel or Structural Concrete New, Reroof (Tear-Off) or Recover
3A Concrete New or Reroof (Tear-Off)
3B Concrete New or Reroof (Tear-Off)
3C Concrete New or Reroof (Tear-Off)
4A LWIC New or Reroof (Tear-Off)
4B LWIC New or Reroof (Tear-Off)
4C LWIC New, Reroof (Tear-Off)
5A CWF New or Reroof (Tear-Off)
5B CWF New or Reroof (Tear-Off)
5C CWF New, Reroof (Tear-Off) or Recover
SD CWF New, Reroof (Tear-Off)
6A Gypsum Reroof (Tear-Off)
6B Gypsum Reroof (Tear-Off)
6C Gypsum Reroof (Tear-Off)
6D Gypsum Reroof (Tear-Off)
7A Various Recover
7B Various Recover
Type Description
A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded RoofCover
Mech. Attached Insulation, Bonded Roof Cover
Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
Non-Insulated, Mech. Attached Base Sheet, Bonded RoofCoverNon-Insulated, Mech. Attached Base Sheet, Bonded RoofCover
Non-Insulated, Bonded Roof Cover
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
Mech. Attached Insulation, Bonded Roof Cover
Insulated, Mech. Attached Base Sheet, Bonded RoofCover
A-l Bonded Insulation, Bonded Roof Cover
A-3 BondedTemp Roof/Vapor Barrier, BondedInsulation,BondedRoofCoverNon-Insulated, Bonded Roof Cover
A-l Bonded Insulation, Bonded Roof Cover
A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
A-l Bonded Insulation, Bonded Roof Cover
A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
Mech. Attached Insulation, Bonded Roof Cover
Non-Insulated, Mech. Attached Base Sheet, Bonded RoofCover
A-l Bonded Insulation, Bonded Roof Cover
A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
Mech. Attached Insulation, Bonded Roof Cover
Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
A-l Bonded Insulation, Bonded Roof Cover
Non-Insulated, Bonded Roof Cover
TRINITY ERD
Page
5-6
8-9
10-12
13-15
16-17
17
18-20
21-25
26-28
29-36
36
37
38-39
40
41-44
45
46
46
47
48-49
50
51
51
52-57
57
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains toabove-deck roof components. Roof decks shall be in accordance with FBC requirements tothe satisfaction ofthe Authority Having Jurisdiction. Load resistance of theroof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Unless otherwise noted,fastenersand stressplatesfor insulation attachmentshall be as follows. Fasteners shall be of sufficient length forthe following engagements:> Wood Deck: OMG #14 Roofgrip with Flat Bottom Plate (Accutrac), OMG HD with OMG 3in. Galvalume Steel Plate, Dekfast #14 with Hex Plate or3" Round Insulation Plate, Trufast HD with Trufast 3"
MetalInsulation Platesor FlintFast #14 Fastenerwith FlintFast 3" Insulation Plates. Minimum 0.75-inch plywood penetrationor minimum 1-inch woodplankembedment.> Steel Deck: OMG #12 or#14 Roofgrip with Recessed orFlat Bottom Plate (Accutrac), OMG #12 Standard orHD with OMG 3in. Galvalume Steel Plate, Dekfast #12 or#14 with Hex Plate or3"Round
Insulation Plate, Trufast DP or HD with Trufast 3" Metal Insulation Plates or FlintFast #12 or#14 Fastener with FlintFast 3" Insulation Plates. Minimum 0.75-inch steel penetration andengage the top flute of the steel deck.
> Structural Concrete: OMG #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG HD or CD-10 with OMG 3 in. Galvalume Steel Plate, Dekfast #14 or DekSpike with Hex Plate or 3" RoundInsulation Plate, Trufast HD or CF with Trufast 3"Metal Insulation Plates or FlintFast #14 Fastener with FlintFast 3"Insulation Plates. Minimum 1-inch embedment. Fasteners installedwith a pilot hole in accordance with the fastener manufacturer's published installation instructions.
Exterior Research and Design, LLC. d/b/a Trinity)ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic" Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20:09/14/2017Appendix 1, Page 1 of 57
TRINITY ERD3. Unless otherwise noted, insulation maybe anyone layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, GlasRoc Roof Board or gypsum-based roofboard that meetsthe QA requirements
of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
4. Minimum 200 psi,minimum 2-inch thicklightweight insulating concrete may be substituted for, or installed beneath rigid insulation board for System Type D(mechanically attached base sheet, bonded roofcover),whereby the base sheet screws and platesare installed throughthe LWIC to engagethe structural steel or concretedeck. Thestructural deck shall be of equalor greaterconfiguration to the steel and concretedecklistings. Roof decks andstructural members shall be inaccordance with FBC requirements to the satisfaction ofthe Authority Having Jurisdiction. Load resistance ofthe roof deck shall bedocumented through propercodified and/or FBCApproval documentation.
5. Preliminary insulationattachment for SystemTypeD: Unless otherwise noted, refer to Section 2.2.10.1.3of FM Loss Prevention DataSheet 1-29 (January2016).
6. Unless otherwise noted, insulation adhesive application ratesare as follows. Ribbon or beadwidth isat the timeofapplication; the ribbons/beads shall expand as notedinthe manufacturer's published instructions.> Hot asphalt (HA): Fullcoverage at 25-30 lbs/square> Ashland Pliodeck (A-PD): Continuous 0.75inch wide ribbons, 12-inch o.c. Ribbons ofsubsequent layers shall beperpendicular tothose inthe layer below.> Dow INSTA-STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1 inch wide ribbons, 12-inch o.c.> Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.> Millennium PG-1Pump Grade Adhesive (M-PG1): Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c.> OMG OlyBond 500 or OlyBond Green (OB500): Continuous 0.75-inch wide ribbons,12-incho.c. (PaceCart or SpotShot)> ICP Adhesives CR-20: Continuous 2.5 to 3-inch wide ribbons, 12-inch o.c.> Note: When multiple layers(s) of insulation and/orcoverboard areinstalled inribbon-applied adhesive, boards shallbestaggeredfromlayer-to-layer.> Note: The maximum edgedistancefromtheadhesive ribbon to theedgeof theinsulation board shallbenotless than one-half thespecified ribbons spacing.
7. Unless otherwise noted, allinsulations are flat-stock or taperboard ofthe minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may besubstituted with the following MaximumDesign Pressure (MDP) limitations. In nocase shall these values be used to 'increase' the MDP listings inthe tables; rather ifMDP listing below meets or exceeds that listed for a particular system in the tables, thenthe thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table:
> Ashland Pliodeck (A-PD) @ 12-inch o.c.> Ashland Pliodeck (A-PD) <S> 6-inch o.c.> Dow INSTA-STIK Quik Set Insulation Adhesive (D-IS):> Millennium One Step Foamable Adhesive (M-OSFA):> Millennium PG-1 Pump Grade Adhesive (M-PG1):> OMG OlyBond 500 (OB500):> OMG OlyBond 500 (OB500):> OMG OlyBond 500 (OB500):> OMG OlyBond 500 (OB500):> ICP Adhesives CR-20:
8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
9. For mechanically attachedcomponents or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined inaccordance with FBCChapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM LossPrevention Data Sheet 1-29 andRoofing Application Standard RAS 117. Assemblies marked with anasterisk* carry the limitations set forth inSection 2.2.10.1 ofFM Loss Prevention Data Sheet 1-29 (January 2016) forZone 2/3 enhancements.
10. For assemblies with all components fully bonded in place, the maximum design pressure for theselected assembly shall meet orexceed critical design pressure determined inaccordance with FBC Chapter 16, and norational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. Aqualified design professional shall review the data for comparison to theminimumrequirements for the system. Testingand analysisshall be in accordance with ANSI/SPRI FX-1 or TestingApplication Standard TAS 105.
Exterior Research andDesign, LLC. d/b/a Trinity | ERD Evaluation Report 3520.03.04-R20 forFL2533-R19Certificate ofAuthorization #9503 6™ EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-S847 Appendix 1,Page 2of57
MDP -105.0 psf (Min. 1.0-inch)MDP -277.5 psf (Min. 1.0-inch)MDP -120.0 psf (Min. 1.0-inch)MDP -157.5 psf (Min. 1.0-inch)MDP -157.5 psf (Min. 1.0-inch)MDP -45.0 psf (Min. 0.5-inch Multi-Max FA3)MDP -187.5 psf (Min. 0.5-inch ISO 95+ GL)MDP -315.0 psf (Min. 0.5-inch ENRGY 3)MDP -487.5 psf (Min. 0.5-inch ACFoam II)MDP -117.5 psf (Min. 1.0-inch)
TRINITY ERD12. For existing substrates in abonded recover or re-roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance withANSI/SPRI IA-l, ASTM E907, FM Loss Prevention DataSheet 1-52or Testing Application StandardTAS 124.
13. ForConcrete Deckor RecoverApplications usingSystemType D,the insulationis optional.
14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWCProduct Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-mches.For LWCover structural concrete, reference is made to FBCSection 1917.4.1, Point 1
15. Unlessotherwise noted, refer to the following references for bonded base, plyor cap sheet applications.
Reference
BP-AA
(Base and Plysheets, Asphatt-Apptied)
BP-AA2
(Base, Spot Asphalt-Applied)
BP-AA3
(Base, Spot-Asphatt-Applied)
BP-AA4
(Base, Strlp-AsphallApplied)
BP-CA2
BP-CA3
SBS-AA
(SBS, Asphalt-Applied)
SBS-CA1
(SBS, Cold-Applied)
SBS-CA2
(SBS, Cold-Applied)
Layer
Base
Ply
Base
Base
Base
Base/Ply
Base/Ply
Base
Ply
Cap
Base
Note:
Ply
Cap
Base
Ply
Cap
Exterior Research and Design, LLC. d/b/a Trinity IERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
CertainTeed Funtiastcc* Modified Bitumen Components & Appucation Methods
Material
Glasbase; All Weather/Empire Base; FlexiglasBase; Flintlastic Base 20
One or more Flintglas Ply4; Flintglas Premium Ply6
Yosemite Venting Base
Yosemite Venting Base
Yosemite Venting Base
Glasbase; All Weather/Empire Base; Flexiglas Base; FlintlasticBase 20
Glasbase; AllWeather/Empire Base; FlexiglasBase; Flintlastic Base 20
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
One or more Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Flintlastic Cap 30; Flintlastic Cap 30CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30CoolStar; Flintlastic FR DualCap; Flintlastic FR-P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar;FlintlasticGMS; FlintlasticGMS CoolStar
Flintlastic Base 20; Flintlastic PolySMS Base; Flintlastic Ultra PolySMS Base
Base ply cures overnight prior to application of the plyor cap ply.
Flintlastic Base 20; Flintlastic PolySMS Base; Flintlastic Ultra PolySMS Base
Flintlastic FR Cap 30;Flintlastic FR Cap 30CoolStar; Flintlastic FR Dual Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar;Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStarFlintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Flintlastic Base 20; Flintlastic PolySMS Base; Flintlastic Ultra Poly SMS Base
Flintlastic Cap 30;Flintlastic Cap 30CoolStar; Flintlastic FR Cap 30;Flintlastic FR Cap 30CoolStar; Flintlastic FR DualCap; Flintlastic FR-P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar;FlintlasticGMS; FlintlasticGMSCoolStar _^__
Application
Hot asphalt at 20-40 lbs/square
Hot asphalt in 24-inch diameter spots in 30-inch grid pattern
Hot asphalt in 9-inch diameter spots in gridpattern noted herein.
Hot asphalt in 9-inch wide ribbons spacedas noted herein.
Henry#903 Adhesive at 1.5 gal/square
Millennium Hurricane Force Membrane
Adhesive, beads spaced 6-inch o.c.
Hot asphalt at 20-40 lbs/square
FlintBond Brush or Karnak No. 81 Cold
Process Modified Bitumen Adhesive Brush
Grade at 1 gal/square
Henry#903 Adhesive at 1.5 gal/square.
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic" Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017Appendix 1, Page 3 of 57
TRINITY ERD
CertainTeed Funtiastic* Modified Bitumen Components & Application Methods (continued)
Reference Layer Material Application
SBS-CA3
(SBS, Cold-Applied)
Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Millennium Hurricane Force Membrane
Adhesive, beads spaced 6-inch o.c.
Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Cap Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; Flintlastic FRCap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR DualCap; Flintlastic FR-P; Flintlastic FR-PCoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-PCoolStar;Flintlastic GMS; Flintlastic GMS CoolStar
SBS-TA
(SBS, Torch-Applied)
Base Flintlastic Ultra Poly SMS Base; Flintlastic Base 20 T
Torch-AppliedPly One or more Flintlastic Ultra Poly SMS Base; Flintlastic Base 20 T
Cap Flintlastic FRCap 30 T; Flintlastic FRCap 30 T CoolStar; Flintlastic GTS; Flintlastic GTS CoolStar; Flintlastic GTS-FR;Flintlastic GTS-FRCoolStar; FlintClad
APP-TA
(APP, Torch-Applied)
Base One or more Flintlastic APP Base T; Flintlastic STA; Flintlastic STA Plus
Torch-AppliedCap Flintlastic STA; Flintlastic STA Plus; Flintlastic GTA; Flintlastic GTA CoolStar; Flintlastic GTA-FR; Flintlastic GTA-FRCoolStar
SBS-SA-H
(SBS, Self-Adhering. Hybrid Systems)
Base/Ply Black Diamond Base Sheet; Flintlastic Ultra Glass SASelf-Adhering
SBS-SA
(SBS, Self-Adhering)
Base Flintlastic SA PlyBase; Flintlastic SA Mid Ply
Self-AdheringPly Flintlastic SA PlyBase; Flintlastic SA Mid Ply
Cap Flintlastic SACap; Flintlastic SACap CoolStar; Flintlastic SACap FR;Flintlastic SACap FRCoolStar
16. "MDP" =Maximum Design Pressure is the resultof testingforwindload resistance based on allowable windloads.Refer to FBC 1609for determinationof design windloads.
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19
Revision 20: 09/14/2017Appendix 1, Page 4 of 57
TRINITY ERD
TABLE 1A: WOOD DECKS - NEW CONSTRUCTION or REROOF(Tear-Off)
SYSTEM TYPE A-2: MECHANICALLYATTACHEDANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
Sys.
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) MDP
(psf)Type Fasteners Attach Type Attach Type Attach Base Ply Cap
Self-Adhering Systems:
W-l
Min. 19/32-
inch
plywood atmax. 24-
inch spans
Glasbase, All
Weather Empire,
Flexiglas Base,Flintlastic Base 20;
Poly SMS; Ultra PolySMS; Yosemite
32 ga., 1-5/8-inch dia. tin
caps with 11 ga.
annular ring
shank nails
9-inch o.c. in 4-inch
lap and 12-inch o.c.in two (2), equallyspaced, staggeredcenter rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA
Min. 0.25-inch
Dens Deck
primed withFlintPrime or
FlintPrime SA
HA SBS-SA(Optional)
SBS-SASBS-SA -45.0*
W-2
Min. 19/32-
inch
plywood at
max. 24-
inch spans
Glasbase, All
Weather Empire,
Flexiglas Base, PolySMS or Ultra Poly
SMS
32 ga., 1-5/8-inch dia. tin
caps with 11 ga.annular ringshank nails
8-inch o.c. in 3-inch
lap and 8-inch o.c.in three (3), equallyspaced, staggeredcenter rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA full
coverage or
OB500, M-
OSFA, A-PD,
D-IS or CR-20,
4-inch o.c.
Min. 0.25-inch
Dens Deck
primed with
FlintPrime or
FlintPrime SA
HA full
coverage or
OB500, M-
OSFA, A-PD, D-
IS or CR-20, 6-
inch o.c.
SBS-SA(Optional)
SBS-SASBS-SA -52.5
W-3
Min. 19/32-
inch
plywood at
max. 24-
inch spans
Yosemite Venting
Base Sheet
32 ga., 1-5/8-inch dia. tin
caps with 11 ga.annular ring
shank nails
8-inch o.c. in 3-inch
lap and 8-inch o.c.in three (3), equallyspaced, staggered
center rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA
Min. 0.25-inch
Dens Deck
primed with
FlintPrime or
FlintPrime SA
HA SBS-SA(Optional)SBS-SA
SBS-SA -52.5
W-4
Min. 19/32-inch
plywood atmax. 24-
inch spans
Glasbase, AllWeather Empire,
Flexiglas Base, PolySMS or Ultra Poly
SMS
32 ga., 1-5/8-inch dia. tin
caps with 11 ga.
annular ring
shank nails
8-inch o.c. in 3-inch
lap and 8-inch o.c.in three (3), equallyspaced, staggered
center rows
(Optional) Min.1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA full
coverage or
OB500, M-
OSFA, A-PD,
D-IS or CR-20,
4-inch o.c.
Min. 0.25-inch
SECUROCK
Gypsum-FiberRoof Board
primed with
FlintPrime or
FlintPrime SA
HA full
coverage or
OB500, M-
OSFA, A-PD, D-
IS or CR-20, 6-
inch o.c.
SBS-SA(Optional)
SBS-SASBS-SA -60.0
W-5
Min. 19/32-
inch
plywood atmax. 24-
inch spans
Yosemite Venting
Base Sheet
32 ga., 1-5/8-inch dia. tin
caps with 11 ga.annular ring
shank nails
8-inch o.c. in 3-inch
lap and 8-inch o.c.in three (3), equallyspaced, staggeredcenter rows
(Optional) Min.1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA
Min. 0.25-inch
SECUROCK
Gypsum-Fiber
Roof Board
primed withFlintPrime or
FlintPrime SA
HA SBS-SA(Optional)SBS-SA
SBS-SA -60.0
Hybrid Systems:
W-6
Min. 19/32-
inch
plywood atmax. 24-
inch spans
Glasbase, All
Weather Empire,
Flexiglas Base,Flintlastic Base 20;
Poly SMS; Ultra Poly
SMS; Yosemite
32 ga., 1-5/8-inch dia. tin
caps with 11 ga.
annular ring
shank nails
9-inch o.c. in 4-inch
lap and 12-inch o.c.in two (2), equallyspaced, staggeredcenter rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA None N/A SBS-SA-H
(Optional)BP-AA, SBS-
AA, SBS-TA
orAPP-TA
SBS-AA,
SBS-TA
orAPP-
TA
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6thEDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 5 of 57
TRINITY ERDTABLE 1A: WOOD DECKS - NEW CONSTRUCTION or REROOF (Tear-Off)
SYSTEMTYPEA-2: MECHANICALLY ATTACHED ANCHORSHEET, BONDED INSULATION, BONDED ROOF COVER
Sys.
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) MDP
(psf)Type Fasteners Attach Type Attach Type Attach Base Ply Cap
W-7
Min. 19/32-inch
plywood atmax. 24-
inch
Glasbase; FlintglasPremium Ply 6;
Yosemite
32 ga., 1-5/8-inch dia. tin
caps with 11 ga.annular ringshank nails
8-inch o.c. in 3-inch
lap and 8-inch o.c.in three (3), equallyspaced, staggeredcenter rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,ENRGY-3, H-Shield
or Multi-Max FA3
HA None N/A SBS-SA-H
(Optional)BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-60.0
Conventional Systems:
W-8
Min. 19/32-
inch
plywood at
max. 24-
inch spans
Glasbase, All
Weather Empire,Flexiglas Base,Flintlastic Base 20;Poly SMS; Ultra PolySMS; Yosemite
32 ga., 1-5/8-inch dia. tin
caps with 11 ga.annular ringshank nails
9-inch o.c. in 4-inch
lap and 12-inch o.c.
in two (2), equallyspaced, staggeredcenter rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA
Min. 0.25-inch
Dens Deck
primed withFlintPrime (ASTMD41) primer
HA
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-45.0*
W-9
Min. 19/32-
inch
plywood atmax. 24-
inch spans
Glasbase, All
Weather Empire,Flexiglas Base, PolySMS or Ultra Poly
SMS
32 ga., 1-5/8-inch dia. tin
caps with 11 ga.annular ringshank nails
8-inch o.c. in 3-inch
lap and 8-inch o.c.
in three (3), equallyspaced, staggeredcenter rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA full
coverage or
OB500, M-
OSFA, A-PD,
D-IS or CR-20,
4-inch o.c.
Min. 0.25-inch
Dens Deck
primed withFlintPrime (ASTMD41) primer
HA full
coverage or
OB500, M-
OSFA, A-PD, D-IS or CR-20, 6-
inch o.c.
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-52.5
W-10
Min. 19/32-
inch
plywood atmax. 24-
inch spans
Yosemite VentingBase Sheet
32 ga., 1-5/8-inch dia. tin
caps with 11 ga.annular ringshank nails
8-inch o.c. in 3-inch
lap and 8-inch o.c.in three (3), equallyspaced, staggeredcenter rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY-3, H-Shield
or Multi-Max FA3
HA
Min. 0.25-inch
Dens Deck
primed withFlintPrime (ASTMD41) primer
HA
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-52.5
W-ll
Min. 19/32-inch
plywood atmax. 24-
inch spans
Glasbase, All
Weather Empire,Flexiglas Base, PolySMS or Ultra PolySMS
32 ga., 1-5/8-inch dia. tin
caps with 11 ga.annular ringshank nails
8-inch o.c. in 3-inch
lap and 8-inch o.c.
in three (3), equallyspaced, staggeredcenter rows
(Optional) Min.1.5-inch ACFoam
II, FlintBoard ISO,ENRGY-3, H-Shield
or Multi-Max FA3
HA full
coverage or
OB500, M-
OSFA, A-PD,
D-IS or CR-20,
4-inch o.c.
Min. 0.25-inch
SECUROCK
Gypsum-FiberRoof Board
HA full
coverage or
OB500, M-
OSFA, A-PD, D-
IS or CR-20, 6-
inch o.c.
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-60.0
W-12
Min. 19/32-
inch
plywood at
max. 24-
inch spans
Yosemite Venting
Base Sheet
32 ga., 1-5/8-inch dia. tin
caps with 11 ga.annular ringshank nails
8-inch o.c. in 3-inch
lap and 8-inch o.c.
in three (3), equallyspaced, staggeredcenter rows
(Optional) Min.1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY-3, H-Shieldor Multi-Max FA3
HA
Min. 0.25-inch
SECUROCK
Gypsum-FiberRoof Board
HA
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-60.0
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic*Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2S33-R19
Revision 20: 09/14/2017
Appendix 1, Page 6 of 57
TRINITY ERD
TABLE IB: WOOD DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVERSYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDEDTOP INSULATION,BONDEDROOFCOVER
System
No.
Deck
(Note 1)
Base insulation Layer Top Insulation Layer Roof Cover (Note 14)MDP (psf)
Type Fasteners Attach Type Attach Base Ply Cap
Hybrid Systems: —_, ,
W-13
Min. 15/32-inchexterior gradeplywood at max. 24-inch spans
Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
ISOH.
FlintFast #12 or
#14 with
FlintFast 3"
Insulation Plates
1 per 1.33
ft2
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield or
FlintBoard ISOH.
HA, D-IS, M-
OSFA, M-PGl
or OB500
SBS-SA-H (Optional) APP-TA APP-TA -67.5
Conventional Systems: , ,
W-14
Min. 23/32-inchexterior grade
plywood at max. 24-
inch spans
Min. 1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY3, H-Shield
Note 2 1 per 2 ft2
Min. 0.5-inch Structodek
High Density FiberboardRoof Insulation, min. 0.75-
inch FescoBoard
(homogeneous)
HABP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-45.0*
W-15
Min. 23/32-inchexterior gradeplywood at max. 24-inch spans
Min. 1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY3, H-Shield
Note 2 1 per 2 ft2
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board,Dens Deck or Dens Deck
Prime
HA
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-45.0*
W-16
Min. 15/32-inch
exterior gradeplywood at max. 24-inch spans
Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield or FlintBoard
ISOH.
FlintFast #12 or
#14 with
FlintFast 3"
Insulation Plates
1 per 1.33ft2
Optional additional layer(s)of base insulation followed
by Min. 0.25-inch SECUROCKGypsum-Fiber Roof board
HA, D-IS, M-
OSFA, M-PGl
or OB500
APP-TA (Optional) APP-TA APP-TA -90.0
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 7 of 57
TRINITY ERDTABLE IC: WOOD DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVERSYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOFCOVER
System
No.
Deck
(Note 1)Base Insulation Layer
Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Fasteners Attach Base Ply CapSelf-Adhering Systems:
W-17
Min. 15/32-inchplywood at max. 24-inch spans
(Optional) One or more
layers, any combination,loose laid
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Flintfast 3 in. Insulation
Plates with FlintFast #12
or #14
1 per 3.2 ft2 SBS-SA(Optional) SBS-SA
SBS-SA -30.0*
W-18
Min. 19/32-inch
exterior grade plywoodat max. 24-inch spans
(Optional) One or more
layers, any combination,loose laid
Min. 0.25-inch Dens Deck Note 2 1 per 1.33 ft2
Apply FlintPrime or
FlintPrime SA to
board & plates,
followed by SBS-SA
(Optional) SBS-SA
SBS-SA -45.0
W-19
Min. 19/32-inch
exterior grade plywoodat max. 24-inch spans
(Optional) One or more
layers, any combination,loose laid
Min. 3/8-inch SECUROCK
Gypsum-Fiber Roof Board
Flintfast 3 in. Insulation
Plates with FlintFast #12
or #14
1 per 2.7 ft2 SBS-SA(Optional) SBS-SA
SBS-SA -45.0*
W-20
Min. 19/32-inchplywood at max. 24-inch spans
(Optional) One or morelayers, any combination,loose laid
Min. 1.5-inch ACFoam II,
ENRGY3, H-Shield, Multi-MaxFA3 or FlintBoard ISO
Flintfast 3 in. Insulation
Plates with FlintFast #12
or #14
1 per 2 ft2
Apply FlintPrime orFlintPrime SA to
board & plates,
followed by SBS-SA
(Optional) SBS-SA
SBS-SA -45.0*
W-21
Min. 15/32-inch
plywood at max. 24-inch spans
(Optional) One or morelayers, any combination,loose laid
Min. 1.5-inch FlintBoard ISO
FlintFast #14 HD with
FlintFast 3" Insulation
Plates or Trufast HD
with Trufast 3" Metal
Insulation Plates
1 per 1.6 ft2Apply FlintPrime to
board & plates,followed by SBS-SA
(Optional) SBS-SA
SBS-SA -52.5
W-22
Min. 19/32-inchplywood at max. 24-inch spans
(Optional) One or morelayers, any combination,loose laid
Min. 1.5-inch ACFoam II,
ENRGY 3, H-Shield, Multi-Max
FA3 or FlintBoard ISO
Note 2 1 per 1.45 ft2
Apply FlintPrime or
FlintPrime SA to
board & plates,followed by SBS-SA
(Optional) SBS-SA
SBS-SA -60.0
Hybrid Systems:
W-23
Min. 15/32-inch
plywood at max. 24-
inch spans
(Optional) One or more
layers, any combination,loose laid
Min. 0.25-inch Dens Deck;
Dens Deck Prime
Flintfast 3 in. Insulation
Plates with FlintFast #12
or #14
1 per 2 ft2 SBS-SA-H
(Optional) BP-AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-TA
or APP-TA-30.0*
W-24
Min. 15/32-inchplywood at max. 24-inch spans
(Optional) One or morelayers, any combination,loose laid
Min. 1.5-inch FlintBoard ISO
FlintFast #14 HD with
FlintFast 3" Insulation
Plates or Trufast HD
with Trufast 3" Metal
Insulation Plates
1 per 1.6 ft2 SBS-SA-H(Optional) SBS-TA or APP-TA
SBS-TA or APP-
TA-52.5
W-25
Min. 15/32-inch
plywood at max. 24-
inch spans
(Optional) One or more
layers, any combination,loose laid
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY3 or
Multi-Max FA3
Note 2 1 per 1.33 ft2 SBS-SA-H(Optional) BP-AAorSBS-AA
SBS-AA -52.5
W-26
Min. 19/32-inchplywood at max. 24-inch spans
(Optional) One or morelayers, any combination,loose laid
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,FlintBoard ISOH
Note 2 1 per 1.45ft2 SBS-SA-H
(Optional) BP-AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-TA
or APP-TA-60.0
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen RoofSystems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017Appendix 1, Page 8 of 57
TRINITY ERDTABLEIC: WOOD DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)Base Insulation Layer
Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Fasteners Attach Base Ply Cap
W-27
Min. lS/32-inch
plywood at max. 24-inch spans
(Optional) Min. 1.5-inch, Oneor more layers, anycombination, loose laid
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,FlintBoard ISOH
Flintfast 3 in. Insulation
Plates with FlintFast #12
or #14
1 per1.33ft2 SBS-SA-H
(Optional) SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-TA
or APP-TA-75.0
W-28
Min. 19/32-inch
exterior grade plywoodat max. 24-inch spans
(Optional) One or morelayers, any combination,loose laid
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY3 or
Multi-Max FA3
Note 2 1 per1.33ft2 SBS-SA-H(Optional) SBS-TA or APP-TA
SBS-TA or APP-
TA-82.5
Conventional Systems:
W-29
Min. 23/32-inchexterior grade plywoodat max. 24-inch spans
(Optional) One or morelayers, any combination,loose laid
Min. 0.5-inch Structodek HighDensity Fiberboard RoofInsulation, min. 0.75-inchFescoBoard (homogeneous)
Note 2 1 per 2 ft2 BP-AA or SBS-AA
(Optional) BP-AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-TA
or APP-TA-45.0*
W-30
Min. 15/32-inchplywood at max. 24-inch spans
(Optional) One or morelayers, any combination,loose laid
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board,Dens Deck or Dens Deck
Prime
FlintFast #12 or #14 HD
with FlintFast 3"
Insulation Plates
1 per 2 ft2BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) BP-AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-TA
or APP-TA-45.0*
W-31
Min. 15/32-inch
plywood at max. 24-inch spans
(Optional for Recover) Min.1.5-inch, One or more layers,any combination, loose laid
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast #12 or #14 HD
with FlintFast 3"
Insulation Plates
1 per1.45ft2 APP-TA(Optional) APP-TA
APP-TA -60.0
W-32
Min. 19/32-inch
exterior grade plywoodat max. 24-inch spans
(Optional for Concrete orRecover) Min. 2-inch ACFoamII, FlintBoard, H-Shield or
ENRGY3, loose laid.
Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast #12 or #14 HD
with FlintFast 3"
Insulation Plates
1 per1.78ft2BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) BP-AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-TA
or APP-TA-60.0
W-33
Min. 15/32-inch
plywood at max. 24-inch spans
(Optional for Recover) Min.1.5-inch, One or more layers,
any combination, loose laid
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast #12 or #14 HD
with FlintFast 3"
insulation Plates
1 per 1.33ft2 APP-TA(Optional) APP-TA
APP-TA -67.5
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017Appendix 1, Page 9 of 57
TRINITY ERDTABLE ID: WOOD DECKS - NEWCONSTRUCTION, REROOF (Tear-Off) or RECOVER
SYSTEMTYPE D: INSULATED, MECHANICALLY ATTACHED BASESHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP
(psf)Type Attach Base Fasteners Attach Ply CapSelf-Adhering Systems:
W-34
Min. 19/32-inch
plywood at max 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
AttachFlintlastic SA NailBase Note 2
8-inch o.c. at min. 3-inch lap and 8-inch o.c. in two (2), equally spaced,staggered center rows; Stress platesshall be primed with FlintPrime
(ASTM D41) primer or FlintPrime SA
(Optional)
SBS-SASBS-SA -82.5*
W-35
Min. 15/32-inch
plywood at max 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
AttachFlintlastic SA NailBase
Flintfast 3 in. Insulation Plates
with FlintFast #12 or #14;Trufast 3" Metal Insulation
Plates with DP or HD; OMG 3
in. Round Metal Plates with
OMG#14HD
6-inch o.c. at min. 2-inch lap and 6-inch o.c. in three (3), equally spaced,staggered center rows; Stress platesshall be primed with FlintPrime(ASTM D41) primer or FlintPrime SA.
(Optional)SBS-SA
SBS-SA -97.5*
W-36
Min. 15/32-inch
plywood at max 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
AttachFlintlastic SA NailBase
Flintfast 3 in. Insulation Plates
with FlintFast #12 or #14;Trufast 3" Metal Insulation
Plates with DP or HD; OMG 3
in. Round Metal Plates with
OMG #14 HD
6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced,staggered center rows; Stress platesshall be primed with FlintPrime(ASTM D41) primer or FlintPrime SA.
(Optional)SBS-SA
SBS-SA -127.5*
Hybrid Systems:
W-37
Min. 15/32-inchplywood at max 24-inch spans
Min. 1.5-inch, One
or more layers,any combination
Prelim.
Attach
Glasbase; Flexiglas;Flintlastic Base 20; Poly SMSBase; Ultra Poly SMS Base
Flintfast 3 in. Insulation Plates
with FlintFast #12 or #14;Trufast 3" Metal Insulation
Plates with DP or HD; OMG 3
in. Round Metal Plates with
OMG #14 HD
6-inch o.c. at 4-inch lap and 6-incho.c. in three (3), equally spaced,staggered center rows; Stress platesshall be primed with FlintPrime
(ASTM D41) primer or FlintPrime SA.
SBS-SA-HSBS-AA, SBS-
TA or APP-TA-97.5
W-38
Min. 19/32-inch
plywood at max 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase; Flexiglas;Flintlastic Base 20; Poly SMSBase; Ultra Poly SMS Base
Note 2
7-inch o.c. at 3-inch lap and 7-incho.c. in three (3), equally spaced,staggered center rows
SBS-SA-HSBS-AA, SBS-
TA or APP-TA-105.0
W-39
Min. 15/32-inch
plywood at max 24-inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase; Flexiglas;Flintlastic Base 20; Poly SMSBase; Ultra Poly SMS Base
Flintfast 3 in. Insulation Plates
with FlintFast #12 or #14;Trufast 3" Metal Insulation
Plates with DP or HD;OMG 3in. Round Metal Plates with
OMG #14 HD
6-inch o.c. at 4-inch lap and 6-incho.c. in four (4), equally spaced,staggered center rows; Stress platesshall be primed with FlintPrime(ASTM D41) primer or FlintPrime SA.
SBS-SA-HSBS-AA, SBS-
TA or APP-TA-127.5
Conventional Systems:
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666,M EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 10 of 57
TRINITY ERD
TABLE ID: WOOD DECKS - NEW CONSTRUCTION,REROOF(Tear-Off) or RECOVER
SYSTEM TYPE D: INSULATED. MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP
(psf)Type Attach Base Fasteners Attach Ply Cap
W-40
Min. 23/32-inch
exterior gradeplywood at max. 24-inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase; All
Weather/Empire Base;Flexiglas Base; FlintlasticBase 20; Yosemite
Note 2
12-inch o.c. at 4-inch lap and 36-inch
o.c. in two (2), equally spaced,staggered center rows
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-30.0*
W-41
Min. 23/32-inch
exterior gradeplywood at max. 24-inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase; AllWeather/Empire Base;Flexiglas Base; FlintlasticBase 20; Yosemite
Note 2
12-inch o.c. at 4-inch lap and 24-inch
o.c. in two (2), equally spaced,staggered center rows
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-45.0*
W-42
Min. 23/32-inchexterior gradeplywood at max. 24-inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Poly SMS Base; Ultra PolySMS Base
Note 2
12-inch o.c. at 4-inch lap and 36-incho.c. in two (2), equally spaced,staggered center rows
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-45.0*
W-43
Min. 15/32-inchplywood at max 24-
inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase; Flexiglas;Flintlastic Base 20; All
Weather/ Empire Base;Poly SMS Base; Ultra PolySMS Base; Yosemite
Flintfast 3 in. Insulation Plates
with FlintFast #12 or #14;
Trufast 3" Metal Insulation
Plates with DP or HD; OMG 3
in. Round Metal Plates with
OMG#14HD
6-inch o.c. at 4-inch lap and 6-incho.c. in three (3), equally spaced,staggered center rows.
(Optional) BP-AA, SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-97.5
W-44
Min. 15/32-inchplywood at max 24-inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
AttachFlintlastic APP Base T
OMG 3 in. Round Metal Plates
with OMG #14 HD
6-inch o.c. at 4-inch lap and 6-inch
o.c. in three (3), equally spaced,staggered center rows.
APP-TA APP-TA -97.5
W-45
Min. 15/32-inchplywood at max 24-inch spans
One or more
layers, anythickness or
combination
Prelim.
Attach
Glasbase; Flexiglas;Flintlastic Base 20; All
Weather/ Empire Base;Poly SMS Base; Ultra PolySMS Base; Yosemite
Flintfast 3 in. Insulation Plates
with FlintFast #14; Trufast 3"Metal Insulation Plates with
Trufast HD
8-inch o.c. at 4-inch lap and 8-incho.c. at three (3) equally spaced,staggered center rows
(Optional) BP-AA, SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP_TA-97.5
W-46
Min. 19/32-inchplywood at max 24-inch spans
Min. 1.5-inch, One
or more layers,any combination
Prelim.
Attach
Glasbase; Flexiglas;Flintlastic Base 20; Poly SMSBase; Ultra Poly SMS Base;Yosemite
Note 2
7-inch o.c. at 3-inch lap and 7-incho.c. in three (3), equally spaced,staggered center rows
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-105.0
W-47
Min. 19/32-inchplywood at max 24-inch spans
Min. 1.5-inch, One
or more layers,any combination
Prelim.
AttachFlintlastic APP Base T
OMG 3 in. Round Metal Plates
with OMG #14 HD or Dekfast
Hex Plate with Dekfast #14
7-inch o.c. at 3-inch lap and 7-incho.c. in three (3), equally spaced,staggered center rows
APP-TA APP-TA -105.0
W-48
Min. 15/32-inchplywood at max 24-inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase; Flexiglas;
Flintlastic Base 20; Poly SMSBase; Ultra Poly SMS Base;Yosemite
Flintfast 3 in. Insulation Plates
with FlintFast #12 or #14;
Trufast 3" Metal Insulation
Plates with DP or HD; OMG 3in. Round Metal Plates with
OMG #14 HD
6-inch o.c. at 4-inch lap and 6-incho.c. in four (4), equally spaced,staggered center rows.
(Optional) BP-AA, SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-127.5
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 11 of 57
TRINITY ERDTABLE ID: WOOD DECKS- NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVER
SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP
(psf)Type Attach Base Fasteners Attach Ply Cap
W-49
Min. 15/32-inch
plywood at max 24-inch spans
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
AttachFlintlastic APP Base T
OMG 3 in. Round Metal Plates
with OMG #14 HD
6-inch o.c. at 4-inch lap and 6-incho.c. in four (4), equally spaced,staggered center rows.
APP-TA APP-TA -127.5
Cold-Applied Systems:
W-50
Min. 15/32-inchplywood at max 24-
inch spans
Min. 1-inch, One
or more layers,
any combination
Loose-
laid
Glasbase; Flexiglas Base;Flintlastic Base 20; All
Weather / Empire Base;Yosemite Venting Base;
Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMSBase
Flintfast 3 in. Insulation Plates
with FlintFast #12 or #14;
Trufast 3" Metal Insulation
Plates with DP or HD
8-inch o.c. at 4-inch lap and 8-inch
o.c. in three (3), equally spaced,staggered center rows
(Optional)SBS-CAl
SBS-CAl -52.5
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19
Revision 20: 09/14/2017Appendix 1, Page 12 of 57
System
No.
Deck
(Note 1)
Self-Adhering Systems:
W-51
W-52
W-53
W-54
W-55
W-56
W-57
W-58
Min. 15/32-inch plywood at
max 24-inch spans
Min. 15/32-inch plywood at
max 24-inch spans
Min. 19/32-inch plywood at
max. 24-inch spans
Min. 19/32-inch plywood at
max. 24-inch spans
Min. 15/32-inch plywood atmax 24-inch spans
Min. 19/32-inch plywood at
max 24-inch spans
Min. 15/32-inch plywood atmax 24-inch spans
Min. 19/32-inch plywood atmax 24-inch spans
Hybrid Systems:
W-59
W-60
Min. 19/32-inch exterior gradeplywood at max. 24-inch spans
Min. 15/32-inch plywood atmax 24-inch spans
TABLE 1E-1: WOOD DECKS-NEW CONSTRUCTION or REROOF (Tear-Off)SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Base Sheet
Base
Flintlastic SA NailBase
Flintlastic SA NailBase
Flintlastic SA NailBase
Flintlastic SA NailBase
Flintlastic SA NailBase
Flintlastic SA NailBase
Flintlastic SA NailBase
Flintlastic SA NailBase
Glasbase; Flexiglas; FlintlasticBase 20; Ail Weather/ Empire
Base; Poly SMS Base; Ultra PolySMS Base
Glasbase; Flexiglas; FlintlasticBase 20; All Weather / EmpireBase; Poly SMS Base; Ultra PolySMS Base
Fasteners
Simplex MAXX Cap
Min. 1-inch long, 12 ga. Simplex
Metal Cap Nails
32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails
32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails
Simplex MAXX Cap
32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails
Cap nails: 1-inch diameter,0.032-inch thick metal cap with0.120" shank diameter, annular
ring shanknails
32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shank
nails
32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails
Min. 1-inch long, 12 ga. SimplexMetal Cap Nails
Attach
9-inch o.c. at min. 3-inch lap and 12-inch o.c. intwo (2), equally spaced, staggered center rows;Stress plates shall be primed with FlintPrime(ASTM D41) primer.
6-inch o.c. at min. 2-inch lap and 6-inch o.c. infour (4), equally spaced, staggered center rows
8-inch o.c. at min. 2-inch lap and 8-inch o.c. inthree (3), equally spaced, staggered centerrows
8-inch o.c. at min. 2-inch lap and 8-inch o.c. in
three (3), equally spaced, staggered centerrows
8-inch o.c. at min. 3-inch lap and 8-inch o.c. in
three (3), equally spaced, staggered centerrows; Stress plates shall be primed withFlintPrime (ASTM D41) primer.
6-inch o.c. at min. 2-inch lap and 6-inch o.c. in
four (4), equally spaced, staggered center rows
7-inch o.c. at min. 4-inch laps and 7-inch o.c. infive (5), equally spaced, staggered center rows
4-inch o.c. at min. 2-inch lap and 4-inch o.c. infour (4), equally spaced, staggered center rows
9-inch o.c. at 4-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows
6-inch o.c. at 3-inch lap and 6-inch o.c. in four(4), equally spaced, staggered center rows
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
TRINITY ERD
Roof Cover (Note 14)
Ply
(Optional) SBS-
SA
(Optional) SBS-SA
(Optional) SBS-SA
(Optional) SBS-SA
(Optional) SBS-SA
(Optional) SBS-SA
(Optional) SBS-SA
(Optional) SBS-SA
SBS-SA-H
SBS-SA-H
Cap
SBS-SA
SBS-SA
SBS-SA
SBS-SA
SBS-SA
SBS-SA
SBS-SA
SBS-SA
SBS-AA, SBS-TA
or APP-TA
SBS-AA, SBS-TA
or APP-TA
MDP
(psf)
-45.0*
-52.5
-52.5
-60.0
-67.5
-75.0
-75.0
-105.0
-45.0*
-52.5
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 13 of 57
TRINITY ERDTABLE 1E-1: WOOD DECKS- NEW CONSTRUCTION or REROOF (Tear-Off)
SYSTEMTYPEE: NON-INSULATED, MECHANICALLY ATTACHED BASESHEET,BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 14) MDP
(psf)Base Fasteners Attach Ply Cap
W-61Min. 19/32-inch plywood atmax 24-inch spans
Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; Ultra
Poly SMS Base
32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails
8-inch o.c. at 4-inch lap and 8-inch o.c. in three(3), equally spaced, staggered center rows
SBS-SA-HSBS-AA, SBS-TA
or APP-TA-52.5
W-62Min. 19/32-inch plywood atmax 24-inch spans
Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base
32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails
8-inch o.c. at 4-inch lap and 8-inch o.c. in three(3), equally spaced, staggered center rows
SBS-SA-HSBS-AA, SBS-TA
or APP-TA-60.0
W-63Min. 19/32-inch plywood atmax 24-inch spans
Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base
32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails
6-inch o.c. at 4-inch lap and 6-inch o.c. in four(4), equally spaced, staggered center rows SBS-SA-H
SBS-AA, SBS-TA
or APP-TA-82.5
W-64Min. 19/32-inch plywood atmax 24-inch spans
Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base
32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails
4-inch o.c. at 3-inch lap and 4-inch o.c. in four(4), equally spaced, staggered center rows SBS-SA-H
SBS-AA, SBS-TA
or APP-TA-105.0
Conventional Systems:
W-65Min. 19/32-inch exterior gradeplywood at max. 24-inch spans
Glasbase; Flexiglas; FlintlasticBase 20; AllWeather/ EmpireBase; Poly SMS Base; Ultra Poly
SMS Base; Yosemite
32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails
9-inch o.c. at 4-inch lap and 12-inch o.c. in two(2), equally spaced, staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-TA
or APP-TA-45.0*
W-66Min. 15/32-inch exterior gradeplywood at max. 24-inch spans
Glasbase; Flexiglas; FlintlasticBase 20; All Weather / EmpireBase; Poly SMS Base; Yosemite
Simplex MAXX Cap9-inch o.c. at 2-inch lap and 18-inch o.c. in two(2), equally spaced, staggered center rows
(Optional) BP-AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-TA
or APP-TA-45.0*
W-67Min. 15/32-inch exterior gradeplywood at max. 24-inch spans
Flintlastic APP Base T Simplex MAXXCap9-inch o.c. at 2-inch lap and 18-inch o.c. in two(2), equally spaced, staggered center rows
(Optional) APP-TA
APP-TA -45.0*
W-68Min. 15/32-inch plywood atmax 24-inch spans
Glasbase; Flexiglas; FlintlasticBase 20; All Weather / EmpireBase; Poly SMS Base; Ultra PolySMS Base; Yosemite
Min. 1-inch long, 12 ga. SimplexMetal Cap Nails
6-inch o.c. at 3-inch lap and 6-inch o.c. in four(4), equally spaced, staggered center rows
(Optional) BP-AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-TA
or APP-TA-52.5
W-69Min. 19/32-inch plywood atmax 24-inch spans
Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base; Yosemite
32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails
8-inch o.c. at 4-inch lap and 8-inch o.c. in three(3), equally spaced, staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-TA
or APP-TA-52.5
W-70Min. 15/32-inch exterior gradeplywood at max. 24-inch spans
Glasbase; Flexiglas; FlintlasticBase 20; AllWeather / EmpireBase; Poly SMS Base; Yosemite
Simplex MAXX Cap9-inch o.c. at 2-inch lap and 12-inch o.c. in two(2), equally spaced, staggered center rows
(Optional) BP-AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-TA
or APP-TA-52.5
W-71Min. 15/32-inch exterior gradeplywood at max. 24-inch spans
Flintlastic APP Base T Simplex MAXX Cap9-inch o.c. at 2-inch lap and 12-inch o.c. in two(2), equally spaced, staggered center rows
(Optional) APP-TA
APP-TA -52.5
W-72Min. 19/32-inch plywood atmax 24-inch spans
Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base; Yosemite
32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails
8-inch o.c. at 4-inch lap and 8-inch o.c. in three(3), equally spaced, staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-TA
or APP-TA-60.0
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 14 of 57
System
No.
W-73
W-74
W-75
W-76
W-77
W-78
W-79
Deck
(Note 1)
Min. 15/32-inch plywood atmax 24-inch spans
Min. 19/32-inch plywood atmax 24-inch spans
Min. 15/32-inch exterior gradeplywood at max. 24-inch spans
Min. 15/32-inch exterior gradeplywood at max. 24-inch spans
Min. 19/32-inch plywood atmax 24-inch spans
Min. 15/32-inch exterior gradeplywood at max. 24-inch spans
Min. 15/32-inch exterior gradeplywood at max. 24-inch spans
TABLE 1E-1: WOOD DECKS- NEW CONSTRUCTION or REROOF (Tear-Off)
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Base
Glasbase; Flexiglas; FlintlasticBase 20; AllWeather / EmpireBase; Poly SMS Base; Ultra PolySMS Base; Yosemite
Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base; Yosemite
Glasbase; Flexiglas; FlintlasticBase 20; AllWeather / EmpireBase; Poly SMS Base; Yosemite
Flintlastic APP Base T
Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base; Yosemite
Glasbase; Flexiglas; FlintlasticBase 20; AllWeather / EmpireBase; Poly SMS Base; Yosemite
Flintlastic APP Base T
Base Sheet
Fasteners
Cap nails: 1-inch diameter,0.032-inch thick metal cap with0.120-inch shank diameter,
annular ring shank nails.
32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails
Simplex MAXX Cap
Simplex MAXXCap
32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails
Simplex MAXX Cap
Simplex MAXXCap
Attach
6-inch o.c. at 4-inch lap and 6-inch o.c. at five(5) equally spaced, staggered center rows
6-inch o.c. at 4-inch lap and 6-inch o.c. in four(4), equally spaced, staggered center rows
6-inch o.c. at 2-inch lap and 6-inch o.c. in two(2), equally spaced, staggered center rows
6-inch o.c. at 2-inch lap and 6-inch o.c. in two(2), equally spaced, staggered center rows
4-inch o.c. at 3-inch lap and 4-inch o.c. in four(4), equally spaced, staggered center rows
6-inch o.c. at 2-inch lap and 6-inch o.c. in three(3), equally spaced, staggered center rows
6-inch o.c. at 2-inch lap and 6-inch o.c. in three(3), equally spaced, staggered center rows
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
TRINITY ERD
Roof Cover (Note 14)
Ply
(Optional) BP-AA, SBS-AA or
SBS-TA
BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) BP-AA, SBS-AA,SBS-
TA or APP-TA
(Optional) APP-TA
BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) BP-AA, SBS-AA, SBS-
TA or APP-TA
(Optional) APP-TA
Cap
SBS-AA or SBS-
TA
SBS-AA, SBS-TA
or APP-TA
SBS-AA, SBS-TA
or APP-TA
APP-TA
SBS-AA, SBS-TA
or APP-TA
SBS-AA, SBS-TA
or APP-TA
APP-TA
MDP
(psf)
-67.5
-82.5
-90.0
-90.0
-105.0
-105.0
-105.0
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 15 of 57
TRINITY ERDTABLE 1E-2: WOOD DECKS - NEW CONSTRUCTION, REROOF(Tear-Off) or RECOVER
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 14) MDP
(psf)Base Fasteners Attach Ply Cap
Self-Adhering Systems:
W-80Min. 19/32-inch plywoodat max 24-inch spans
Flintlastic SA NailBase Note 2
8-inch o.c. at min. 3-inch lap and 8-inch o.c. in
two (2), equally spaced, staggered center rows.Stress plates shall be primed with FlintPrime(ASTM D41) primer or FlintPrime SA
(Optional)
SBS-SASBS-SA -82.5*
W-81Min. 15/32-inch plywoodat max 24-inch spans
Flintlastic SA NailBase
Flintfast 3 in. Insulation Plates with
FlintFast #12 or #14; Trufast 3" Metal
Insulation Plates with DP or HD; OMG 3
in. Round Metal Plates with OMG #14 HD
6-inch o.c. at min. 2-inch lap and 6-inch o.c. in
three (3), equally spaced, staggered center rows.Stress plates shall be primed with FlintPrime
(ASTM D41) primer or FlintPrime SA.
(Optional)SBS-SA
SBS-SA -97.5*
W-82Min. 15/32-inch plywoodat max 24-inch spans
Flintlastic SA NailBase
Flintfast 3 in. Insulation Plates with
FlintFast #12 or #14; Trufast 3" Metal
Insulation Plates with DP or HD;OMG 3in. Round Metal Plates with OMG #14 HD
6-inch o.c. at min. 2-inch lap and 6-inch o.c. infour (4), equally spaced, staggered center rows.Stress plates shall be primed with FlintPrime(ASTM D41) primer or FlintPrime SA.
(Optional)
SBS-SASBS-SA -127.5*
Hybrid Systems:
W-83Min. 15/32-inch plywoodat max 24-inch spans
Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base
Flintfast 3 in. Insulation Plates with
FlintFast #12 or #14; Trufast 3" Metal
Insulation Plates with DP or HD; OMG 3in. Round Metal Plates with OMG #14 HD
6-inch o.c. at 4-inch lap and 6-inch o.c. in three(3), equally spaced, staggered center rows.Stress plates shall be primed with FlintPrime(ASTM D41) primer or FlintPrime SA.
SBS-SA-HSBS-AA, SBS-
TA or APP-TA-97.5
W-84Min. 19/32-inch plywoodat max 24-inch spans
Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base
Note 27-inch o.c. at 3-inch lap and 7-inch o.c. in three(3), equally spaced, staggered center rows SBS-SA-H
SBS-AA, SBS-
TA or APP-TA-105.0
W-85Min. 15/32-inch plywoodat max 24-inch spans
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base; UltraPoly SMS Base
Flintfast 3 in. Insulation Plates with
FlintFast #12 or #14; Trufast 3" Metal
Insulation Plates with DP or HD; OMG 3
in. Round Metal Plates with OMG #14 HD
6-inch o.c. at 4-inch lap and 6-inch o.c. in four(4), equally spaced, staggered center rows.Stress plates shall be primed with FlintPrime(ASTM D41) primer or FlintPrime SA.
SBS-SA-HSBS-AA, SBS-
TA or APP-TA-127.5
Conventional Systems:
W-86
Min. 23/32-inch exterior
grade plywood at max.24-inch spans
Glasbase; All Weather/EmpireBase; Flexiglas Base; FlintlasticBase 20; Yosemite
Note 212-inch o.c. at 4-inch lap and 36-inch o.c. in two(2), equally spaced, staggered center rows
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-30.0*
W-87
Min. 23/32-inch exterior
grade plywood at max.24-inch spans
Glasbase; All Weather/EmpireBase; Flexiglas Base; FlintlasticBase 20; Yosemite
Note 212-inch o.c. at 4-inch lap and 24-inch o.c. in two
(2), equally spaced, staggered center rows
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-45.0*
W-88
Min. 23/32-inch exteriorgrade plywood at max.24-inch spans
Poly SMS Base; Ultra Poly SMSBase
Note 212-inch o.c. at 4-inch lap and 36-inch o.c. in two(2), equally spaced, staggered center rows
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-45.0*
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19
Revision 20: 09/14/2017Appendix 1, Page 16 of 57
System
No.
W-89
W-90
W-91
W-92
W-93
W-94
W-95
Deck
(Note 1)
Min. 15/32-inch plywoodat max 24-inch spans
Min. 15/32-inch plywoodat max 24-inch spans
Min. 15/32-inch plywood
at max 24-inch spans
Min. 19/32-inch plywoodat max 24-inch spans
Min. 19/32-inch plywoodat max 24-inch spans
Min. 15/32-inch plywoodat max 24-inch spans
Min. 15/32-inch plywoodat max 24-inch spans
TABLE1E-2: WOOD DECKS - NEW CONSTRUCTION,REROOF(Tear-Off) or RECOVER
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Base
Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base; Yosemite
Flintlastic APP Base T
Glasbase; Flexiglas; FlintlasticBase 20; All Weather / EmpireBase; Poly SMS Base; Ultra PolySMS Base; Yosemite
Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base; Yosemite
Flintlastic APP Base T
Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base; Yosemite
Flintlastic APP Base T
Base Sheet
Fasteners
Flintfast 3 in. Insulation Plates with
FlintFast #12 or #14; Trufast 3" MetalInsulation Plates with DP or HD; OMG 3
in. Round Metal Plates with OMG #14 HD
OMG 3 in. Round Metal Plates with OMG
#14 HD
Flintfast 3 in. Insulation Plates with
FlintFast #14; Trufast 3" Metal InsulationPlates with Trufast HD
Note 2
OMG 3 in. Round Metal Plates with OMG
#14 HD or Dekfast Hex Plate with Dekfast
#14
Flintfast 3 in. Insulation Plates with
FlintFast #12 or #14; Trufast 3" MetalInsulation Plates with DP or HD; OMG 3
in. Round Metal Plates with OMG #14 HD
OMG 3 in. Round Metal Plates with OMG
#14 HD
Attach
6-inch o.c. at 4-inch lap and 6-inch o.c. in three(3), equally spaced, staggered center rows
6-inch o.c. at 4-inch lap and 6-inch o.c. in three(3), equally spaced, staggered center rows.
8-inch o.c. at 4-inch lap and 8-inch o.c. at three(3) equally spaced, staggered center rows
7-inch o.c. at 3-inch lap and 7-inch o.c. in three(3), equally spaced, staggered center rows
7-inch o.c. at 3-inch lap and 7-inch o.c. in three(3), equally spaced, staggered center rows
6-inch o.c. at 4-inch lap and 6-inch o.c. in four(4), equally spaced, staggered center rows
6-inch o.c. at 4-inch lap and 6-inch o.c. in four(4), equally spaced, staggered center rows.
TRINITY ERD
Roof Cover (Note 14)
Ply
(Optional) BP-AA, SBS-AA,
SBS-TA or
APP-TA
APP-TA
(Optional) BP-AA, SBS-AA or
SBS-TA
BP-AA, SBS-
AA, SBS-TA or
APP-TA
APP-TA
(Optional) BP-AA, SBS-AA,
SBS-TA or
APP-TA
APP-TA
Cap
SBS-AA, SBS-
TA or APP-TA
APP-TA
SBS-AA or
SBS-TA
SBS-AA, SBS-
TA or APP-TA
APP-TA
SBS-AA, SBS-TA or APP-TA
APP-TA
MDP
(psf)
-97.5
-97.5
-97.5
-105.0
-105.0
-127.5
-127.5
Cold-Applied Systems:
W-96Min. 15/32-inch plywoodat max 24-inch spans
Glasbase; Flexiglas Base;Flintlastic Base 20; All Weather /Empire Base; Yosemite VentingBase; Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base
Flintfast 3 in. Insulation Plates with
FlintFast #12 or #14; Trufast 3" MetalInsulation Plates with DP or HD
8-inch o.c. at 4-inch lap and 8-inch o.c. in three(3), equally spaced, staggered center rows
(Optional)SBS-CAl
SBS-CAl -52.5
System
No.
W-97
W-98
Deck
(Note 1)
Min. 15/32-inch plywood at max 24-inch spans
Min. 15/32-inch plywood at max 24-inch spans
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
TABLE IF: WOOD DECKS - NEW CONSTRUCTION OR REROOF (Tear-Off)
SYSTEM TYPE F:NON-INSULATED, BONDED ROOF COVER
PrimerRoof Cover (Note 14)
Base Ply
FlintPrime or FlintPrime SA SBS-SA-H (Optional) SBS-TA, APP-TA
FlintPrime or FlintPrime SA SBS-SA (Optional) SBS-SA
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
CapMDP (psf)
SBS-TA, APP-TA -112.5
SBS-SA -127.5
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 17 of 57
TRINITY ERDTABLE 2A: STEEL ORSTRUCTURAL CONCRETE DECKS-NEWCONSTRUCTION, REROOF (Tear-Off)or RECOVER
SYSTEMTYPE B: MECHANICALLY ATTACHED BASEINSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Fasteners Attach Type Attach Base Ply CapSelf-Adhering Systems:
S-l
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psistructrual concrete
Min. 2-inch ACFoam II,
FlintBoard, ENRGY 3 or
H-Shield
Note 21 per 4
ft2Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
HA, D-IS, M-
OSFA, OB500
or CR-20
SBS-SA (Optional) SBS-SA SBS-SA -37.5*
S-2
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard, ENRGY3or H-Shield
Note 21 per 2
ft2Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
HA, D-IS, M-
OSFA, OB500or CR-20
SBS-SA (Optional) SBS-SA SBS-SA -45.0*
Hybrid Systems:
S-3
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard, ENRGY3
or H-Shield
Note 21 per
1.45 ft2Additional layer(s) baseinsulation
HA, D-IS, M-
OSFA, OB500
or CR-20
Flintlastic
Ultra
Glass SA
(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA,
SBS-TA,
APP-TA
-37.5
S-4
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard, ENRGY3
or H-Shield
Note 2lper
1.45 ft2Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
HA, D-IS, M-
OSFA, OB500
or CR-20
Flintlastic
Ultra
Glass SA
(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
S-5
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield or FlintBoard
ISOH.
FlintFast #12 or #14 with
FlintFast 3" Insulation Plates
lper
1.45 ft2
Min. 1.5-inch ACFoam II,FlintBoard ISO, H-Shield or
FlintBoard ISOH.
HA, D-IS, M-
OSFA, M-
PGlor
OB500
SBS-SA-H (Optional) APP-TA APP-TA -67.5
S-6
Min. 22 ga., type B, Grade40 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
ISO„
FlintFast 012 (steel only) or 014HD with FlintFast 3" Insulation
Plates or Trufast 012 (steel only)or HD with Trufast 3" Metal
Insulation Plates
1 per 1.6
ft2Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
D-IS, M-
OSFA, M-
PGlor
OB500
SBS-SA-H(Optional) SBS-TAor APP-TA
SBS-TA or
APP-TA-75.0
S-7
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch ENRGY 3
FlintFast 012 (steel only) or 014HD with FlintFast 3" Insulation
Plates or Trufast 012 (steel only)or HD with Trufast 3" Metal
Insulation Plates
1 perl
ft2Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof BoardOB500, 4-
inch o.c.SBS-SA-H
(Optional) SBS-TAor APP-TA
SBS-TA or
APP-TA-90.0*
Conventional Systems:
S-8
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
Min. 2-inch ACFoam II,
FlintBoard, ENRGY3 orH-Shield
Note 2lper 4
ft2Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
HA, D-IS, M-
OSFA, OB500
or CR-20
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-37.5*
S-9
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard, ENRGY3or H-Shield
Note 2lper 2
ft2
Min. 0.5-inch Structodek
High Density FiberboardRoof Insulation, min. 0.75-inch FescoBoard
(homogeneous).
HABP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic*Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19
Revision 20: 09/14/2017
Appendix 1, Page 18 of 57
TRINITY ERD
TABLE 2A: STEEL ORSTRUCTURAL CONCRETE DECKS - NEWCONSTRUCTION, REROOF (Tear-Off)or RECOVERSYSTEM TYPE B: MECHANICALLY ATTACHED BASEINSULATION, BONDED TOPINSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Fasteners Attach Type Attach Base Ply Cap
S-10
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard, ENRGY3or H-Shield
Note 21 per 2
ft2Min. 0.25-inch Dens Deck
or Dens Deck PrimeHA
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-ll
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
Min. l.S-inch ACFoam
II, FlintBoard, ENRGY3
or H-Shield
Note 2lper 2
ft2Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
HA, D-IS, M-
OSFA, OB500
or CR-20
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-12
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
Min. 2-inch ACFoam II,
FlintBoard, ENRGY 3 or
H-Shield
Note 2lper 3.2
ft2
Min. 0.5-inch Structodek
High Density FiberboardRoof Insulation, min. 0.75-
inch FescoBoard
(homogeneous).
HABP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-13
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
Min. 2-inch ACFoam II,
FlintBoard, ENRGY 3 or
H-Shield
Note 21 per 3.2
ft2
Min. 0.25-inch Dens Deck
or Dens Deck PrimeHA
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-14
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard, ENRGY 3or Mult-Max FA3
Note 2lper
1.33 ft2
Min. 0.75-inch FescoBoard
(homogeneous)HA
BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-52.5
S-15
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
Min. 2-inch ACFoam II,
FlintBoard, ENRGY3 or
H-Shield
Note 21 per 1.6
ft2Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
HA, D-IS, M-
OSFA, OB500
or CR-20
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional) BP-AA,SBS-AA,SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
S-16
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
Min. l.S-inch ACFoam
II, FlintBoard, ENRGY 3or Mult-Max FA3
Note 21 per
1.33 ft2Min. 0.5-inch Structodek
High Density FiberboardHA
BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-67.5
S-17
Min. 22 ga., type B,Grade40 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
iso„
FlintFast 012 (steel only) or 014HD with FlintFast 3" Insulation
Plates or Trufast 012 (steel only)or HD with Trufast 3" Metal
Insulation Plates
1 per 1.6
ft2
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
D-IS, M-
OSFA, M-
PGlor
OB500
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional) BP-AA,SBS-AA,SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-75.0
S-18
Min. 22 ga., type B,Grade33 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch ENRGY 3
FlintFast 012 (steel only) or 014HD with FlintFast 3" Insulation
Plates or Trufast 012 (steel only)or HD with Trufast 3" Metal
Insulation Plates
lperl
ft2Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof BoardOB500, 4-
inch o.c.
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-90.0*
Cold-Appued Systems:
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 19 of 57
TRINITY ERDTABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION, REROOF (Tear-Off) orRECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVERSystem
No.
Deck
(Note 1)Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Fasteners Attach Type Attach Base Ply Cap
S-19
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
Min. 2-inch ACFoam II,FlintBoard ISO, H-Shield or FlintBoard
ISO„
FlintFast 012 (steel only) or 014HD with FlintFast 3" Insulation
Plates or Trufast 012 (steel only)or HD with Trufast 3" Metal
Insulation Plates
lper 2
ft2
Min. 1.5-inch ACFoam III,FlintBoard Iso Cold, H-Shield CG or FlintBoard Iso
Cold„
OB500 or
CR-20SBS-CAl None SBS-CAl -45.0*
S-20
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
Min. 2-inch ACFoam II,FlintBoard ISO, H-Shield or FlintBoard
iso„
FlintFast 012 (steel only) or 014HD with FlintFast 3" Insulation
Plates or Trufast 012 (steel only)or HD with Trufast 3" Metal
Insulation Plates
lper 2
ft2
Optional min. 1.5-inch
additional layer(s) baseinsulation, followed bymin. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
D-IS, M-
OSFA, M-PG1, OB500
or CR-20
SBS-CAl None SBS-CAl -45.0*
S-21
Min. 22 ga., type B, Grade40 steel or min. 2,500 psistructrual concrete
Min. l.S-inch ACFoam
II, FlintBoard ISO, H-Shield or FlintBoard
ISOH
FlintFast 012 (steel only) or 014HD with FlintFast 3" Insulation
Platesor Trufast 012 (steel only)or HD with Trufast 3" Metal
Insulation Plates
lper 1.6
ft2Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
D-IS, M-
OSFA, M-
PGlor
OB500
SBS-CAl None SBS-CAl -75.0
S-22
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch ENRGY 3
FlintFast012 (steel only) or 014HD with FlintFast 3" Insulation
Plates or Trufast 012 (steel only)or HD with Trufast 3" Metal
Insulation Plates
1 perl
ft2Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof BoardOB500, 4-
inch o.c.SBS-CAl None SBS-CAl -90.0*
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen RoofSystems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 20 of 57
TRINITY ERD
TABLE2B: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)Base Insulation Layer(s)
Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Fasteners Attach Base Ply Cap
Self-Adhering Systems:
S-23
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
Note 2 1 per3.2 ft2 SBS-SA (Optional) SBS-SA SBS-SA -30.0*
S-24
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or#14 HD with FlintFast 3"
Insulation Plates or Trufast #12
(steel only) or HDwith Trufast3" Metal Insulation Plates
1 per2.7ft2 SBS-SA (Optional) SBS-SA SBS-SA -37.5*
S-25
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
(Optional) One or morelayers, any combination,
loose laid
Min. 3/8-inchSECUROCK Gypsum-
Fiber Roof Board
Note 2 lper 2.7 ft2 SBS-SA (Optional) SBS-SA SBS-SA -45.0*
S-26
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or morelayers, any combination,
loose laid
Min. 0.25-inch Dens
DeckNote 2 1 per1.33ft2
Apply FlintPrime or
FlintPrime SA to
board & plates,
followed by SBS-SA
(Optional) SBS-SA SBS-SA -45.0
S-27
Min. 22 ga., type B, Grade40 steel or min. 2,500 psi
structrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 1.5-inch
FlintBoard ISO
FlintFast #14 HD with FlintFast
3" Insulation Plates or Trufast
HD with Trufast 3" Metal
Insulation Plates
1 per1.78 ft2Apply FlintPrime to
board & plates,
followed by SBS-SA
(Optional) SBS-SA SBS-SA -67.5
S-28
Min. 22 ga., type B, Grade40 steel or min. 2,500 psi
structrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #14 HD with FlintFast
3" Insulation Plates or Trufast
HD with Trufast 3" Metal
Insulation Plates
1 per1.6 ft2Apply FlintPrime toboard & plates,
followed by SBS-SA(Optional) SBS-SA SBS-SA -82.5
Hybrid Systems:
S-29
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 0.25-inch Dens
Deck; Dens Deck
Prime
Note 2 1 per2 ft2 SBS-SA-H
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-30.0*
S-30
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
(Optional) One or morelayers, any combination,
loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or#14 HD with FlintFast 3"
Insulation Plates or Trufast #12
(steel only) or HDwith Trufast3" Metal Insulation Plates
lper 2.7 ft2 SBS-SA-H
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-37.5*
S-31
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psistructrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 3/8-inch
SECUROCKGypsum-Fiber Roof Board
FlintFast #12 (steel only) or#14 HD with FlintFast 3"
Insulation Plates or Trufast #12
(steel only) or HD with Trufast3" Metal Insulation Plates
lper 2.7 ft2 SBS-SA-H
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 21 of 57
TRINITY ERDTABLE 2B: STEEL ORSTRUCTURAL CONCRETE DECKS- NEWCONSTRUCTION, REROOF (Tear-Off) or RECOVER
SYSTEM TYPE C: MECHANICALLYATTACHED INSULATION, BONDED ROOFCOVER
System
No.
Deck
(Note 1)Base Insulation Layer(s)
Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Fasteners Attach Base Ply Cap
S-32
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY 3 or Multi-Max
FA3
Note 2 1 per 1.33 ft2 SBS-SA-H(Optional) BP-AAor SBS-AA
SBS-AA -52.5
S-33
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psistructrual concrete
(Optional) One or more
layers, any combination,loose laid
Min. 1.5-inch
FlintBoard ISO
FlintFast #14 HD with FlintFast
3" Insulation Plates or Trufast
HD with Trufast 3" Metal
Insulation Plates
1 per 1.78 ft2 SBS-SA-H(Optional) SBS-TAor APP-TA
SBS-TA or
APP-TA-67.5
S-34
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
(Optional) One or more
layers, any combination,loose laid
Min. l.S-inch ACFoam
II, FlintBoard ISO, H-Shield or FlintBoard
ISOH.
FlintFast #12 (steel only) or#14 HD with FlintFast 3"
Insulation Plates
1 per 1.45 ft2 SBS-SA-H(Optional) SBS-AA,SBS-TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-75.0
S-35
Min. 22 ga., type B, Grade40 steel or min. 2,500 psistructrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 0.5-inch
SECUROCKGypsum-Fiber Roof Board
FlintFast #14 HD with FlintFast
3" Insulation Plates or Trufast
HD with Trufast 3" Metal
Insulation Plates
1 per 1.6 ft2 SBS-SA-H(Optional) SBS-TAor APP-TA
SBS-TA or
APP-TA-82.5
S-36
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 0.5-inch
SECUROCKGypsum-Fiber Roof Board
FlintFast #12 (steel only) or#14 HD with FlintFast 3"
Insulation Plates or Trufast #12
(steel only) or HD with Trufast3" Metal Insulation Plates
1 per 1.45ft2 SBS-SA-H(Optional) SBS-TAor APP-TA
SBS-TA or
APP-TA-82.5
S-37
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psistructrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. l.S-inch ACFoam
II, FlintBoard ISO,
ENRGY 3 or Multi-Max
FA3
Note 2 1 per 1.33 ft2 SBS-SA-H(Optional) SBS-TAor APP-TA
SBS-TA or
APP-TA-82.5
S-38
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psistructrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 0.5-inch
SECUROCKGypsum-Fiber Roof Board
FlintFast #12 (steel only) or#14 HD with FlintFast 3"
Insulation Plates or Trufast #12
(steel only) or HD with Trufast3" Metal Insulation Plates |
1 per 1 ft2 SBS-SA-H(Optional) SBS-TAor APP-TA
SBS-TA or
APP-TA-135.0
Conventional Systems:
S-39
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 0.7S-inch
FescoBoard
(homogeneous)Note 2 lper 2.67 ft2 BP-AA, SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-30.0*
S-40
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 0.5-inch
Structodek HighDensity FiberboardRoof Insulation
Note 2 1 per 4 ft2 BP-AA, SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TAorAPP-TA
SBS-AA,
SBS-TA or
APP-TA
-37.5*
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666thEDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19
Revision 20: 09/14/2017Appendix 1, Page 22 of 57
TRINITY ERD
TABLE 2B: STEEL ORSTRUCTURAL CONCRETE DECKS- NEWCONSTRUCTION, REROOF (Tear-Off) or RECOVERSYSTEM TYPE C: MECHANICALLYATTACHED INSULATION, BONDED ROOFCOVER
SystemNo.
Deck
(Note 1)Base Insulation Layer(s)
Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Fasteners Attach Base Ply Cap
S-41
Min. 22 ga., type B,Grade33 steel or min. 2,500 psi
structrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
Note 2 1 per4 ft2 BP-AA, SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-37.5*
S-42
Min. 22 ga., type B,Grade33 steel or min. 2,500 psi
structrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 2-inch ACFoam II,
FlintBoard or ENRGY 3Note 2 1 per1.6ft2 BP-AA2
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-37.5*
S-43
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 0.25-inch
SECUROCKGypsum-
Fiber Roof Board
Note 2 lper 4 ft2BP-AA, SBS-AA,
SBS-TA or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-44
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 0.5-inch
Structodek HighDensity FiberboardRoof Insulation, min.
0.75-inch FescoBoard
(homogeneous)
Note 2 1 per 2 ft2 BP-AA or SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-45
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 0.25-inch Dens
Deck or Dens Deck
Prime
Note 2 1 per 2 ft2BP-AA, SBS-AA,
SBS-TA or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-46
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 1-inch
FescoBoard
(homogeneous) ormin. 1.5-inch
FescoBoard
(laminated)
Note 2 1 per 1.6ft2 BP-AA2
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-47
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 0.5-inch
Structodek,
Structodek HD, GP HD
Roof Fiberboard or
Temple HDl or HD6
Note 2 1 per 2 ft2 BP-AA2
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-48
Min. 22 ga., type B,Grade33 steel or min. 2,500 psistructrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 1.5-inch ACFoam
II, FlintBoardNote 2 1 per 1.45ft2
BP-AA3, 24-inch
grid
(Optional) BP-AAor SBS-AA
SBS-AA -52.5
S-49
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. l.S-inch ACFoam
II, FlintBoardNote 2 1 per 1.45ft2
BP-AA3, 24-inch
gridBP-AA or SBS-AA SBS-TA -52.5
S-50
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
(Optional for Concrete orRecover) Min. 1.5-inch,One or more layers, anycombination, loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or#14 HD with FlintFast 3"
Insulation Plates
1 per1.45ft2 APP-TA (Optional) APP-TA APP-TA -60.0
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 23 of 57
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6™ EDITION (2017)FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
TRINITY ERDTABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVER
SYSTEMTYPEC: MECHANICALLY ATTACHED INSULATION, BONDED ROOFCOVERSystem
No.
Deck
(Note 1)Base Insulation Layer(s)
Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Fasteners Attach Base Ply Cap
S-51
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
(Optional for Concrete orRecover) Min. 2-inch
ACFoam II, FlintBoard, H-
Shield or ENRGY 3, looselaid.
Min. 0.5-inch
SECUROCKGypsum-
Fiber Roof Board
Note 2 1 per 1.78 ft2 BP-AA, SBS-AA,
SBS-TA or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
S-52
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psistructrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 0.5-inch
SECUROCK Gypsum-Fiber Roof Board
FlintFast #12 (steel only) or#14 HD with FlintFast 3"
Insulation Plates or Trufast #12
(steel only) or HDwith Trufast3" Metal Insulation Plates
1 per 1.45 ft2 BP-AA, SBS-AA,
SBS-TA or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-82.5
S-53
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psistructrual concrete
(Optional for Concrete orRecover) Min. l.S-inchACFoam II, FlintBoard, H-Shield
Min. 0.5-inch Dens
Deck Prime
Trufast HD with Trufast 3"
Metal Insulation Plates or
FlintFast #14 with FlintFast 3"
Insulation Plates
lper 1.33 ft2 BP-AA, SBS-AA(Optional) BP-AA,SBS-AA
SBS-AA -112.5
S-54
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 0.5-inch
SECUROCK Gypsum-Fiber Roof Board
FlintFast #12 (steel only) or#14 HD with FlintFast 3"
Insulation Plates or Trufast #12
(steel only) or HDwith Trufast3" Metal Insulation Plates
1 per 1 ft2 BP-AA, SBS-AA,
SBS-TA or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TAor
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-135.0
S-55
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
(Optional for Concrete orRecover) Min. 1.5-inch
ACFoam II, FlintBoard, H-Shield
Min. 0.5-inch
SECUROCK Gypsum-Fiber Roof Board
Trufast HD with Trufast 3"
Metal Insulation Plates or
FlintFast #14 with FlintFast 3"
Insulation Plates
1 per 1.33 ft2 BP-AA, SBS-AA(Optional) BP-AA,SBS-AA
SBS-AA -157.5
S-56
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
(Optional for Concrete orRecover) Min. 1.5-inchACFoam II, FlintBoard, H-Shield
Min. 0.5-inch Dens
Deck Prime
Trufast HD with Trufast 3"
Metal Insulation Plates or
FlintFast #14 with FlintFast 3"
Insulation Plates
1 per 1 ft2 BP-AA, SBS-AA(Optional) BP-AA,SBS-AA
SBS-AA -157.5
S-57
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
(Optional for Concrete orRecover) Min. 1.5-inch
ACFoam II, FlintBoard, H-Shield |
Min. 0.5-inch
SECUROCK Gypsum-Fiber Roof Board
Trufast HD with Trufast 3"
Metal Insulation Plates or
FlintFast #14 with FlintFast 3"
Insulation Plates
1 per 1 ft2 BP-AA, SBS-AA(Optional) BP-AA,SBS-AA
SBS-AA -172.5
S-58
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 0.25-inch
SECUROCK Gypsum-Fiber Roof Board
FlintFast #12 (steel only) or#14 HD with FlintFast 3"
Insulation Plates or Trufast #12
(steel only) or HD with Trufast3" Metal Insulation Plates
1 per 2.7 ft2 SBS-CAl None SBS-CAl -37.5*
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610)651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19
Revision 20: 09/14/2017Appendix 1, Page 24 of 57
TRINITY ERD
TABLE 2B: STEEL ORSTRUCTURAL CONCRETE DECKS-NEWCONSTRUCTION, REROOF (Tear-Off)or RECOVERSYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)Base Insulation Layer(s)
Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Fasteners Attach Base Ply Cap
S-59
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. l.S-inch ACFoam
III, FlintBoard Iso Cold,H-Shield CG or
FlintBoard Iso ColdH
FlintFast #12 (steel only) or#14 HD with FlintFast 3"
Insulation Plates or Trufast #12
(steel only) or HDwith Trufast3" Metal Insulation Plates
1 per 2 ft2 SBS-CAl None SBS-CAl -45.0*
S-60
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 3/8-inchSECUROCKGypsum-Fiber Roof Board
FlintFast #12 (steel only) or#14 HD with FlintFast 3"
Insulation Plates or Trufast #12
(steel only) or HDwith Trufast3" Metal Insulation Plates
1 per 2.7 ft2 SBS-CAl None SBS-CAl -45.0*
S-61
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
(Optional) One or morelayers, any combination,loose laid
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or#14 HD with FlintFast 3"
Insulation Plates or Trufast #12
(steel only) or HDwith Trufast3" Metal Insulation Plates
1 per 1.45ft2 SBS-CAl None SBS-CAl -82.5*
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic" Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report352Q.03.04-R20 for FL2533-R19Revision 20:09/14/2017
Appendix 1, Page 25 of 57
TRINITY erdTABLE 2C: STEEL ORSTRUCTURAL CONCRETE DECKS- NEWCONSTRUCTION, REROOF (Tear-Off) or RECOVER
SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHEDBASE SHEET, BONDEDROOFCOVERNote: Insulation optional for Recoveror Concrete Deckappucavons (Note 14)
System
No.
Deck
(Note 1)
Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP
(psf)Type Attach Base Fasteners Attach Ply CapSelf-Adhering Systems:
S-62
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch, One
or more layers, anycombination
Prelim.
AttachedFlintlastic SA NailBase Note 2
9-inch o.c. at min. 2-inch lap and18-inch o.c. in two (2), equallyspaced, staggered center rows
(Optional) SBS-SA
SBS-SA -45.0*
S-63
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch, One
or more layers, anycombination
Prelim.
AttachedFlintlastic SA NailBase Note 2
12-inch o.c. at min. 2-inch lap and12-inch o.c. in two (2), equallyspaced, staggered center rows
(Optional) SBS-SA
SBS-SA -52.5*
S-64
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, anycombination
Prelim.
AttachedFlintlastic SA NailBase Note 2
12-inch o.c. at min. 4-inch lap and12-inch o.c. in two (2), equallyspaced, staggered center rows
(Optional) SBS-SA
SBS-SA -60.0*
S-65
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch, One
or more layers, anycombination
Prelim.
Attached
Flintlastic SA NailBase
(laid parallel to deck
flutes)Note 2
8-inch o.c. at min. 4-inch lap and 8-inch o.c. in two (2), equally spaced,staggered center rows
(Optional) SBS-SA
SBS-SA -82.5*
Conventional Systems:
S-66
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch, One
or more layers, anycombination
Prelim.
Attached
Glasbase; All
Weather/Empire Base;Flexiglas Base; FlintlasticBase 20; Yosemite
Note 2
12-inch o.c. at 4-inch lap and 36-inch o.c. in two (2), equally spaced,staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA-30.0*
S-67
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch, One
or more layers, anycombination
Prelim.
Attached
Glasbase; All
Weather/Empire Base;Flexiglas Base; FlintlasticBase 20; Yosemite
Note 2
12-inch o.c. at 4-inch lap and 24-inch o.c. in two (2), equally spaced,staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA-45.0*
S-68
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Poly SMS Base; Ultra PolySMS Base
Note 2
12-inch o.c. at 4-inch lap and 36-inch o.c. in two (2), equally spaced,staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA-45.0*
S-69
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch, One
or more layers, anycombination
Prelim.
Attached
Poly SMS Base; Ultra PolySMS Base
Note 2
18-inch o.c. at 4-inch lap and 18-inch o.c. in one (1) staggeredcenter row
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA-45.0*
S-70
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch, One
or more layers, anycombination
Prelim.
Attached
Poly SMS Base; Ultra PolySMS Base
Dekfast IF-2-SBplates with#14 Dekfast
12-inch o.c. within the min. 4-inch
wide, heat-welded side lapSBS-AA, SBS-TA
or APP-TA
SBS-AA, SBS-
TA or APP-TA-45.0*
S-71
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch, One
or more layers, anycombination
Prelim.
Attached
Glasbase; Flexiglas Base;Flintlastic Base 20; All
Weather / Empire Base;Poly SMS Base; Yosemite
Note 2
12-inch o.c. at 3-inch lap and 12-inch o.c. in two (2), equally spaced,staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA-52.5
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19
Revision 20: 09/14/2017
Appendix 1, Page 26 of 57
TRINITY ERD
TABLE 2C: STEEL ORSTRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVERSYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Note: Insulationoptional for Recoveror ConcreteDeckappucations(Note 14)
System
No.
Deck
(Note 1)
Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP
(psf)Type Attach Base Fasteners Attach Ply Cap
S-72
Min. 22 ga., type B, 40 ksisteel or min. 2,500 psi
structrual concrete
Min. 2-inch, One or
more layers, any
combination
Prelim.
AttachedUltra Poly SMS Base
Trufast 2" Barbed Metal
Seam Plates with Trufast
#15EHD(sree/on/y;orTrufast #14 HD (concreteonly)
12-inch o.c. within the min. 4-inch
wide, heat-welded side lap
(Optional) SBS-TA or APP-TA
SBS-TA or
APP-TA-52.5
S-73
Min. 22 ga., type B, Grade80 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, anycombination
Prelim.
AttachedUltra Poly SMS Base
Trufast 2.4" Barbed Metal
Seam Plates with Trufast
#15EHDfsree/on/WorTrufast #14 HD (concrete
only)
12-inch o.c. within the min. 4-inch
wide, heat-welded side lap
(Optional) SBS-TA or APP-TA
SBS-TA or
APP-TA-60.0
S-74
Min. 22 ga., type B, 40 ksisteel or min. 2,500 psi
structrual concrete
Min. 2-inch, One or
more layers, anycombination
Prelim.
AttachedUltra Poly SMS Base
Trufast 2.4" Scoop Seam
Plates with Trufast #15
EHD (steel only) or Trufast#14 HD(concrete only)
12-inch o.c. within the min. 4-inch
wide, heat-welded side lap
(Optional) SBS-TA or APP-TA
SBS-TA or
APP-TA-67.5
S-75
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
AttachedGlasbase; Yosemite
OMG Flat Bottom Plates
with OMG #14 HD
(Accutrac)
6-inch o.c. at 4-inch lap and 6-inch
o.c. in two (2), equally spaced,staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA-67.5
S-76
Min. 22 ga., type B, Grade33 steel or min. 2,500 psi
structrual concrete
Min. l.S-inch, One
or more layers, anycombination
Prelim.
Attached
Flexiglas Base; FlintlasticBase 20; Yosemite
Note 2
6-inch o.c. at 4-inch lap and 6-incho.c. in two (2), equally spaced,staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA-67.5
S-77
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
Min. 1.5-inch, One
or more layers, anycombination
Prelim.
Attach
Glasbase; Flexiglas;Flintlastic Base 20; All
Weather / Empire Base;Poly SMS Base; Ultra PolySMS Base; Yosemite
Flintfast 3 in. Insulation
Plates with FlintFast #14;
Trufast 3" Metal Insulation
Plates with Trufast HD
6-inch o.c. at 4-inch lap and 6-inch
o.c. at three (3) equally spaced,staggered center rows
(Optional) BP-
AA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA-97.5
S-78
Min. 22 ga., type B, 40 ksisteel or min. 2,500 psi
structrual concrete
Min. 2-inch, One or
more layers, anycombination
Prelim.
AttachedUltra Poly SMS Base
Trufast 2.4" Scoop SeamPlates with Trufast #15
EHD(steel only) or Trufast#14 HD (concrete only)
6-inch o.c. within the min. 4-inch
wide, heat-welded side lap
(Optional) SBS-TA or APP-TA
SBS-TA or
APP-TA-112.5
S-79
Min. 22 ga., type B, Grade80 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Poly SMS Base; Ultra PolySMS Base
Note 2
12-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced,staggered center rows
SBS-TA or APP-
TA
SBS-TA or
APP-TA-112.5
S-80
Min. 22 ga., type B, Grade80 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Poly SMS Base; Ultra PolySMS Base
Note 2
12-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced,staggered center rows
SBS-AASBS-AA or
SBS-TA-120.0
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6™ EDITION (2017)FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 27 of 57
TRINITY ERD
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVERSYSTEM TYPE D: INSUUTED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
Note:Insulation optional for Recover or Concrete Deckappucations (Note14)System
No.
Deck
(Note 1)Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP
(psf)Type Attach Base Fasteners Attach Ply Cap
S-81
Min. 22 ga., type B, 40 ksi
steel or min. 2,500 psistructrual concrete
Min. 2-inch, One or
more layers, anycombination
Prelim.
AttachedUltra Poly SMS Base
Trufast 2.4" Scoop SeamPlates with Trufast #15
EHD(steel only) or Trufast#14 HD(concrete only)
6-inch o.c. within the min. 4-inch
wide, heat-welded side laps and 6-inch o.c. in one (1) center row,stripped-in with 6-inch side stripsof torch-applied PolySMSBase orUltra Poly SMS Base.
(Optional) SBS-TA or APP-TA
SBS-TA or
APP-TA-165.0
S-82
Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete
Min. l.S-inch, One
or more layers, anycombination
Prelim.
Attached
Glasbase; All
Weather/Empire Base;Flexiglas Base; FlintlasticBase 20
Note 2
6-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced,staggered center rows
SBS-CAl SBS-CAl -45.0*
S-83
Min. 22 ga., type B, Grade40 steel or min. 2,500 psistructrual concrete
Min. 1-inch, One or
more layers, anycombination
Loose-la id
Glasbase; Flexiglas Base;Flintlastic Base 20; AllWeather/ Empire Base;Yosemite Venting Base;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMSBase
FlintFast #14 HD with
FlintFast 3" Insulation
Plates or Trufast HD with
Trufast 3" Metal Insulation
Plates
6-inch o.c. at 4-inch lap and 12-inch o.c. in three (3), equallyspaced, staggered center rows
(Optional) SBS-CAl
SBS-CAl -75.0
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeedFlintlastic* Modified Bitumen Roof Systems; (610)651-5847
Evaluation Report 3520.O3.O4-R20 for FL2533-R19
Revision 20: 09/14/2017Appendix 1, Page 28 of 57
TRINITY ERD
TABLE3A: STRUCTURALCONCRETE DECKS-NEW CONSTRUCTION or REROOF(Tear-Off)
SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER
Sys.
No.
Deck
(Note 1)Primer
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Attach Type Attach Base Ply Cap
Self-Adhering Systems:
C-l.Structural
concrete
FlintPrime
(ASTM D41)
Min. 1.5-inch ACFoam II, FlintBoard,ENRGY 3 or H-Shield
HAMin. 0.25-inch SECUROCKGypsum-
Fiber Roof BoardHA SBS-SA (Optional) SBS-SA SBS-SA -172.5
C-2.Structural
concrete
FlintPrime
(ASTM D41)
Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or Multi-Max FA3HA
Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA
HA SBS-SA (Optional) SBS-SA SBS-SA -192.5
C-3.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoard,ENRGY 3 or Multi-Max FA3
A-PDMin. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA
A-PD SBS-SA (Optional) SBS-SA SBS-SA -105.0
C-4.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoard,ENRGY 3 or H-Shield
A-PDMin. 0.25-inch SECUROCK Gypsum-
Fiber Roof BoardA-PD SBS-SA (Optional) SBS-SA SBS-SA -172.5
C-5.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or Multi-Max FA3
A-PD
6-inch o.c.
Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA
A-PD
6-inch o.c.SBS-SA (Optional) SBS-SA SBS-SA -192.5
C-6.Structural
concrete
(Optional)FlintPrime
(ASTM D41)
Min. 1.5-inch Multi-Max FA D-ISMin. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA
D-IS SBS-SA (Optional) SBS-SA SBS-SA -67.5
C-7.Structural
concrete
(Optional)FlintPrime
(ASTMD41)Min. l.S-inch ENRGY 3 D-IS
Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA
D-IS SBS-SA (Optional) SBS-SA SBS-SA -112.5
C-8.Structural
concrete
(Optional)FlintPrime
(ASTM D41)
Min. 1.5-inch ACFoam II or FlintBoard D-ISMin. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA
D-IS SBS-SA (Optional) SBS-SA SBS-SA -120.0
C-9.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or H-ShieldD-IS
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof BoardD-IS SBS-SA (Optional) SBS-SA SBS-SA -172.5
C-10.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or H-Shield
M-OSFA or
M-PGl
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
M-OSFA or
M-PGlSBS-SA (Optional) SBS-SA SBS-SA -172.5
C-ll.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or Multi-Max FA
M-OSFA or
M-PGl
Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA
M-OSFA or
M-PGlSBS-SA (Optional) SBS-SA SBS-SA -192.5
C-12.Structural
concrete
FlintPrime
(ASTM D41)
Min. 1.5-inch ACFoam II, FlintBoard ISOor ENRGY 3
OB500Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA
OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0
C-13.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoard ISO
or ENRGY 3OB500
Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA
OB500 SBS-SA (Optional) SBS-SA SBS-SA -150.0
C-14.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoard,ENRGY 3 or H-Shield
OB500Min. 0.25-inch SECUROCKGypsum-
Fiber Roof BoardOB500 SBS-SA (Optional) SBS-SA SBS-SA -172.5
C-15.Structural
concreteNone
Min. 1.0-inch ISO 95+ GL, H-Shield, H-
Shield CG, ENRGY 3 or min. 1.3-inchACFoam III, Min. 1.5-inch Multi-MaxFA3 or Ultra-Max
CR-20Min. 0.25-inch SECUROCKGypsum-
Fiber Roof BoardCR-20 SBS-SA (Optional) SBS-SA SBS-SA -172.5
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6thEDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 29 of 57
TRINITY ERDTABLE 3A: STRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION or REROOF (Tear-Off)
SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER
Sys.
No.
Deck
(Note 1)Primer
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Attach Type Attach Base Ply Cap
C-16.Structural
concreteNone
Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY3 or min. 1.3-inch
ACFoam III, Min. 1.5-inch Multi-MaxFA3 or Ultra-Max
CR-20Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA
CR-20 SBS-SA (Optional) SBS-SA SBS-SA -192.5
Hybrid Systems:
C-17.Structural
concrete
FlintPrime
(ASTM D41)Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH
HA(Optional) Additional layer(s) baseinsulation
HA
Flintlastic
Ultra Glass
SA
(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-322.5
C-18.Structural
concrete
FlintPrime
(ASTM D41)Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH
HA(Optional) Additional layer(s) baseinsulation
HA
Black
Diamond
Base Sheet
(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-375.0
C-19.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH
A-PD(Optional) Additional layer(s) baseinsulation
A-PD SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-180.0
C-20.Structural
concreteNone
Min. l.S-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOHA-PD
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
A-PD SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-117.5
C-21.Structural
concreteNone
Min. l.S-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOHA-PD, 6-incho.c.
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
A-PD, 6-inch
o.c.SBS-SA-H
(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-217.5
C-22.Structural
concreteNone
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
A-PD, 6-inch
o.c.None N/A SBS-SA-H
(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-195.0
C-23.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH
D-IS(Optional) Additional layer(s) baseinsulation
D-IS SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-135.0
C-24.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOHD-IS
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
D-IS SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-217.5
C-2S.Structural
concreteNone
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
D-IS None N/A SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-195.0
C-26.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH M-OSFA
(Optional) Additional layer(s) baseinsulation
M-OSFA SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-232.5
C-27.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH
M-OSFAMin. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
M-OSFA SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-217.5
C-28.Structural
concreteNone
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
M-OSFA None N/A SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-195.0
C-29.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH
M-PGl(Optional) Additional layer(s) baseinsulation
M-PGl SBS-SA-H(Optional) 5BS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-270.0
C-30.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH M-PGl
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
M-PGl SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-217.5
C-31.Structural
concreteNone
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
M-PGl None N/A SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-195.0
Exterior Research and Design, LLC. d/b/a Trinity| ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 30 of 57
TRINITY ERDTABLE3A: STRUCTURALCONCRETE DECKS- NEW CONSTRUCTIONor REROOF(Tear-Off)
SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER
Sys.
No.
Deck
(Note 1)Primer
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Attach Type Attach Base Ply Cap
C-32.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH
OB500(Optional) Additional layer(s) baseinsulation
OB500 SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-135.0
C-33.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH
OB500Min. 0.25-inch SECUROCKGypsum-
Fiber Roof BoardOB500 SBS-SA-H
(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-217.5
C-34.Structural
concreteNone
Min. 0.25-inch SECUROCKGypsum-
Fiber Roof BoardOB500 None N/A SBS-SA-H
(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-195.0
C-35.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH
CR-20(Optional) Additional layer(s) baseinsulation
CR-20 SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-270.0
C-36.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOHCR-20
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof BoardCR-20 SBS-SA-H
(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-217.5
C-37.Structural
concreteNone
Min. 0.25-inch SECUROCKGypsum-
Fiber Roof BoardCR-20 None N/A SBS-SA-H
(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-195.0
Conventional Systems:
C-38.Structural
concrete
FlintPrime
(ASTM D41)
Min. 1.5-inch ACFoam II, ENRGY 3, H-
Shield, FlintBoard ISOHA
(Optional) Additional layer(s) ofbase insulation
HABP-AA3, 24-
inch grid
(Optional) BP-AA,SBS-AA
SBS-AA -37.5
C-39.Structural
concrete
FlintPrime
(ASTM D41)Min. 1.5-inch ACFoam II or FlintBoard
ISO.HA
Min. 0.25-inch Dens Deck, Dens
Deck PrimeHA SBS-TA (Optional) SBS-TA SBS-TA -180.0
C-40.Structural
concrete
FlintPrime
(ASTM D41)
(Optional) Min. 1.5-inch ACFoam IIorFlintBoard ISO.
HAMin. 0.25-inch SECUROCK Gypsum-
Fiber Roof BoardHA
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-180.0
C-41.Structural
concrete
FlintPrime
(ASTM D41)
(Optional) Min. 2-inch ACFoam II,FlintBoard ISO, ENRGY 3 or H-Shield
HAMin. 0.25-inch SECUROCKGypsum-
Fiber Roof BoardHA
BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-225.0
C-42.Structural
concrete
FlintPrime
(ASTM D41)
(Optional) Min. 1.5-inch ACFoam II,FlintBoard ISO, H-Shield, FlintBoard
ISO„
HAMin. 0.25-inch SECUROCKGypsum-
Fiber Roof BoardHA APP-TA (Optional) APP-TA APP-TA -252.5
C-43.Structural
concrete
FlintPrime
(ASTM D41)
Min. l.S-inch ACFoam II, FlintBoardISO, ENRGY 3 or H-Shield
HAMin. 0.5-inch Structodek High
Density FiberboardHA
BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-227.0
C-44.Structural
concrete
FlintPrime
(ASTM D41)
(Optional) Min. 2-inch ACFoam II,FlintBoard ISO, ENRGY3 or H-Shield
HAMin. 0.25-inch SECUROCKGypsum-
Fiber Roof BoardHA
SBS-TA or
APP-TA
(Optional) SBS-TAor APP-TA
SBS-TA or
APP-TA-232.5
C-45.Structural
concrete
FlintPrime
(ASTM D41)
Min. l.S-inch ACFoam II, FlintBoard
ISO, ENRGY3 or H-ShieldHA Min. 0.25-inch Dens Deck HA
BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-240.0
C-46.Structural
concrete
FlintPrime
(ASTM D41)
Min. 1.5-inch ACFoam II or FlintBoard
ISOHA
Min. 0.75-inch FescoBoard
(homogeneous)HA
BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-412.0
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20:09/14/2017
Appendix 1, Page 31 of 57
TRINITY ERDTABLE3A: STRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION OR REROOF(Tear-Off)
SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER
Sys.
No.
Deck
(Note 1)Primer
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Attach Type Attach Base Ply Cap
C-47.Structural
concrete
FlintPrime
(ASTM D41)Min. 1.5-inch ACFoam II or FlintBoard
ISOHA
Min. 0.5-inch DuraBoard
(homogeneous)HA
BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-430.0
C-48.Structural
concrete
FlintPrime
(ASTM D41)
0.5-inch Structodek High DensityFiberboard or min. 0.75-inch Fesco
Board (homogeneous)HA None N/A BP-AA
(Optional) BP-AAor
SBS-AASBS-AA -437.5
C-49.Structural
concrete
FlintPrime
(ASTM D41)0.25-inch Dens Deck, Dens Deck Prime
or SECUROCKGypsum-Fiber Roof BoardHA None N/A SBS-TA
(Optional) SBS-AAor SBS-TA
SBS-AA or
SBS-TA-302.5
C-50.Structural
concrete
FlintPrime
(ASTM D41)Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
HA None N/A
Flintlastic
Ultra PolySMS Base,
torched
(Optional) FlintlasticUltra Poly SMSBase, torched
SBS-TA -487.5
C-51.Structural
concrete
FlintPrime
(ASTM D41)0.25-inch Dens Deck, Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof BoardHA None N/A BP-AA
(Optional) BP-AAorSBS-AA
SBS-AA -537.5
C-52.Structural
concreteNone
Min. l.S-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-ShieldA-PD
Min. 0.5-inch Structodek HighDensity Fiberboard or Min. 0.25-inch Dens Deck
A-PDBP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-105.0
C-53.Structural
concreteNone
Min. l.S-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield
A-PD
6-inch o.c.
Min. 0.5-inch Structodek HighDensity Fiberboard or Min. 0.25-inch Dens Deck
A-PD
6-inch o.c.
BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-217.5
C-54.Structural
concreteNone
Min. l.S-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOHA-PD
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
A-PD
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-117.5
C-55.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISO„
A-PD, 6-inch
o.c.
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
A-PD, 6-inch
o.c.
BP-AA, SBS-AA, SBS-TA
or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-217.5
C-56.Structural
concreteNone
0.5-inch Structodek High DensityFiberboard
A-PD, 6-inch
o.c.None N/A
BP-AA, SBS-
AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-195.0
C-57.Structural
concreteNone
Min. 0.25-inch Dens Deck, Dens Deck
Prime or SECUROCK Gypsum-Fiber RoofBoard
A-PD, 6-inch
o.c.None N/A
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-195.0
C-58.Structural
concreteNone
Min. 1.5-inch ACFoam II or FlintBoard
ISO.D-IS Min. 0.25-inch Dens Deck D-IS SBS-TA (Optional) SBS-TA SBS-TA -112.5
C-59.Structural
concreteNone
Min. l.S-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOHD-IS Min. 0.25-inch Dens Deck Prime D-IS
BP-AA, SBS-
AA
(Optional) BP-AA,SBS-AA or SBS-TA
SBS-AA or
SBS-TA-297.5
C-60.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOHD-IS Min. 0.25-inch Dens Deck Prime D-IS SBS-TA (Optional) SBS-TA SBS-TA -302.5
Exterior Research and Design, LLC.Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE
d/b/a Trinity | ERD
59166
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19
Revision 20: 09/14/2017Appendix 1, Page 32 of 57
TRINITY ERD
TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (Tear-Off)SYSTEM TYPE A-l: BONDEDINSULATION, BONDEDROOFCOVER
Sys.
No.
Deck
(Notel)Primer
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Attach Type Attach Base Ply Cap
C-61.Structural
concreteNone
Min. 2-inch ACFoam II, FlintBoard ISO,ENRGY 3 or H-Shield
D-ISMin. 0.25-inch SECUROCKGypsum-
Fiber Roof BoardD-IS
BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-225.0
C-62.Structural
concreteNone
Min. 2-inch ACFoam II, FlintBoard ISO,ENRGY 3 or H-Shield
D-ISMin. 0.25-inch SECUROCK Gypsum-
Fiber Roof BoardD-IS
SBS-TA or
APP-TA
(Optional) SBS-TAor APP-TA
SBS-TA or
APP-TA-232.5
C-63.Structural
concreteNone
Min. l.S-inch ACFoam II, FlintBoardISO,H-Shield, FlintBoard ISOH
D-ISMin. 0.25-inch SECUROCKGypsum-
Fiber Roof BoardD-IS APP-TA (Optional) APP-TA APP-TA -252.5
C-64.Structural
concreteNone
Min. l.S-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH
D-ISMin. 0.2S-inch SECUROCKGypsum-
Fiber Roof BoardD-IS
BP-AA, SBS-
AA or SBS-
TA
(Optional) BP-AA,SBS-AA or SBS-TA
SBS-AA or
SBS-TA-297.5
C-65.Structural
concreteNone
0.5-inch Structodek High Density
FiberboardD-IS None N/A
BP-AA, SBS-
AA
(Optional) BP-AA,SBS-AA, SBS-TAor
APP-TA
SBS-AA, SBS-
TA or APP-TA-195.0
C-66.Structural
concreteNone
Min. 0.25-inch SECUROCKGypsum-
Fiber Roof BoardD-IS None N/A
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TAor
APP-TA
SBS-AA, SBS-
TA or APP-TA-195.0
C-67.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoardISO,ENRGY 3 or H-Shield
M-OSFAMin. 0.5-inch Structodek High
Density FiberboardM-OSFA
BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TAor
APP-TA
SBS-AA, SBS-
TA or APP-TA-127.5
C-68.Structural
concreteNone
Min. l.S-inch ACFoam II, FlintBoard
ISO,ENRGY 3 or H-ShieldM-PGl
Min. 0.5-inch Structodek High
Density FiberboardM-PGl
BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-180.0
C-69.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoardISO, ENRGY 3 or H-Shield
M-OSFA Min. 0.25-inch Dens Deck M-OSFABP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-232.5
C-70.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoardISO, ENRGY 3 or H-Shield
M-PGl Min. 0.25-inch Dens Deck M-PGlBP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-240.0
C-71.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoardISO,H-Shield, FlintBoard ISOH
M-PGl Min. 0.25-inch Dens Deck Prime M-PGlBP-AA, SBS-
AA
(Optional) BP-AA,SBS-AA or SBS-TA
SBS-AA or
SBS-TA-297.5
C-72.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoardISO,H-Shield, FlintBoard ISOH
M-PGl Min. 0.25-inch Dens Deck Prime M-PGl SBS-TA (Optional) SBS-TA SBS-TA -302.5
C-73.Structural
concreteNone
Min. 2-inch ACFoam II, FlintBoard ISO,ENRGY 3 or H-Shield
M-OSFA or
M-PGl
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
M-OSFA or
M-PGl
BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-225.0
C-74.Structural
concreteNone
Min. 2-inch ACFoam II, FlintBoard ISO,ENRGY 3 or H-Shield
M-OSFA or
M-PGl
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
M-OSFA or
M-PGl
SBS-TA or
APP-TA
(Optional) SBS-TAor APP-TA
SBS-TA or
APP-TA-232.5
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic" Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 33 of 57
TRINITY ERDTABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (Tear-Off)
SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOFCOVER
Sys.
No.
Deck
(Note 1)Primer
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Attach Type Attach Base Ply Cap
C-75.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH
M-OSFA or
M-PGl
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
M-OSFA or
M-PGlAPP-TA (Optional) APP-TA APP-TA -252.5
C-76.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH
M-OSFA or
M-PGl
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
M-OSFA or
M-PGl
BP-AA, SBS-
AA or SBS-
TA
(Optional) BP-AA,SBS-AA or SBS-TA
SBS-AA or
SBS-TA-297.5
C-77.Structural
concreteNone
0.5-inch Structodek High DensityFiberboard
M-PGl None N/ABP-AA, SBS-
AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-195.0
C-78.Structural
concreteNone
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board M-PGl None N/ABP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-195.0
C-79.Structural
concreteNone
Min. l.S-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-ShieldOB500
Min. 0.5-inch Structodek HighDensity Fiberboard
OB500BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-120.0
C-80.Structural
concreteNone
Min. 1.5-inch ACFoam II or FlintBoard
ISO.OB500
Min. 0.25-inch Dens Deck or Dens
Deck PrimeOB500
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-150.0
C-81.Structural
concreteNone
Min. l.S-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOHOB500 Min. 0.2S-inch Dens Deck Prime OB500
BP-AA, SBS-
AA or SBS-
TA
(Optional) BP-AA,SBS-AA or SBS-TA
SBS-AA or
SBS-TA-297.5
C-82.Structural
concreteNone
Min. 2-inch ACFoam II, FlintBoard ISO,ENRGY 3 or H-Shield
OB500Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
OB500BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-225.0
C-83.Structural
concreteNone
Min. 2-inch ACFoam II,FlintBoard ISO,ENRGY 3 or H-Shield
OB500Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
OB500SBS-TA or
APP-TA
(Optional) SBS-TAor APP-TA
SBS-TA or
APP-TA-232.5
C-84.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOHOB500
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
OB500 APP-TA (Optional) APP-TA APP-TA -252.5
C-85.Structural
concreteNone
Min. 1.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOHOB500
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
OB500
BP-AA, SBS-
AA or SBS-
TA
(Optional) BP-AA,SBS-AA or SBS-TA
SBS-AA or
SBS-TA-297.5
C-86.Structural
concreteNone
0.5-inch Structodek High DensityFiberboard
OB500 None N/ABP-AA, SBS-
AA
(Optional) BP-AA,SBS-AA, SBS-TA orAPP-TA
SBS-AA, SBS-
TA or APP-TA-195.0
C-87.Structural
concreteNone
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
OB500 None N/ABP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-195.0
Exterior Research and Design, LLC. d/b/a Trinity| ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 34 of 57
TRINITY ERD
TABLE 3A: STRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION OR REROOF (Tear-Off)SYSTEMTYPEA-l: BONDED INSULATION, BONDED ROOFCOVER
Sys.
No.
Deck
(Note l)Primer
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Attach Type Attach Base Ply Cap
C-88.Structural
concreteNone
Min. 1.0-inch ISO 95+ GL, H-Shield, H-
Shield CG, ENRGY 3 or min. 1.3-inchACFoam III, Min. 1.5-inch Multi-Max
FA3 or Ultra-Max
CR-20
Min. 0.5-inch Structodek HighDensity Fiberboardor DuraBoard(homogeneous) or min. l.S-inchFescoBoard (laminated)
CR-20BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-180.0
C-89.Structural
concreteNone
Min. 1.0-inch ISO 95+ GL, H-Shield, H-
Shield CG, ENRGY3 or min. 1.3-inchACFoam III, Min. 1.5-inch Multi-MaxFA3 or Ultra-
CR-20Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof BoardCR-20
BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SB5-AA, SBS-
TA or APP-TA-225.0
C-90.Structural
concreteNone
Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inchACFoam III, Min. 1.5-inch Multi-MaxFA3 or Ultra-Max
CR-20Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof BoardCR-20
SBS-TA or
APP-TA
(Optional) SBS-TAor APP-TA
SBS-TA or
APP-TA-232.5
C-91.Structural
concreteNone
Min. 1.0-inch ISO 95+ GL, H-Shield, H-
Shield CG, ENRGY 3 or min. 1.3-inchACFoam III, Min. l.S-inch Multi-Max
FA3 or Ultra-Max
CR-20 Min. 0.25-inch Dens Deck CR-20BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-240.0
C-92.Structural
concreteNone
0.5-inch Structodek High Density
FiberboardCR-20 None N/A
BP-AA, SBS-
AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-195.0
C-93.Structural
concreteNone
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof BoardCR-20 None N/A
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-195.0
COLD-APPlied Systems:
C-94.Structural
concreteNone
(Optional) Min. 0.5-inch ACFoam II,FlintBoard ISO, H-Shield, FlintBoardiso„
OB500 or
CR-20
Min. 1.5-inch ACFoam III,
FlintBoard Iso Cold, H-Shield CG or
FlintBoard Iso ColdH
OB500 or
CR-20SBS-CAl None SBS-CAl -82.5
C-95.Structural
concreteNone
Min. 0.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH
A-PD, D-IS,
M-OSFA, M-
PG1, OB500or CR-20
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
A-PD, D-IS,
M-OSFA, M-
PG1, OB500
or CR-20
SBS-CAl None SBS-CAl -105.0
System
No.
Deck
(Note 1)
Cold-Applied Systems:
Primer / Temp Roof
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
TABLE 3B: STRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION OR REROOF (Tear-Off)SYSTEM TYPE A-3:BONDED TEMPROOF, BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer Top Insulation Layer
Type Attach Type Attach
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Base
Roof Cover (Note 14)
Ply CapMDP (psf)
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page35 of 57
TRINITY ERDTABLE 3B: STRUCTURAL CONCRETE DECKS - NEWCONSTRUCTION OR REROOF (Tear-Off)SYSTEMTYPE A-3: BONDED TEMP ROOF,BONDED INSULATION, BONDED ROOFCOVER
System
No.
Deck
(Note 1)Primer / Temp Roof
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14)MDP (psf)Type Attach Type Attach Base Ply Cap
C-96.Structural
concrete
FlintPrime
(ASTMD41)
Flintlastic SA
PlyBase, self-adhered
(Optional) Min. 0.5-inchACFoam II, FlintBoard
ISO, H-Shield, FlintBoardiso„
OB500
Min. 1.5-inch ACFoam III,
FlintBoard Iso Cold, H-Shield
CG or FlintBoard Iso ColdHOB500 SBS-CAl None SBS-CAl -82.5
C-97.Structural
concrete
FlintPrime
(ASTMD41)
Flintlastic SA
PlyBase, self-adhered
Min. 0.5-inch ACFoam II,FlintBoard ISO, H-Shield,FlintBoard ISOH
OB500Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof BoardOB500 SBS-CAl None SBS-CAl -82.5
Exterior Research and Design, LLC. d/b/a Trinity| ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 36 of 57
TRINITY ERDTABLE3C: STRUCTURALCONCRETE DECKS- NEW CONSTRUCTIONor REROOF(Tear-Off)
SYSTEM TYPE F:NON-INSULATED, BONDED ROOF COVER
System
No.
Deck
(Note 1)Primer
Roof Cover (Note 14)MDP (psf)
Base Ply Cap
Self-Adhering Systems:
C-98. | Structural concrete FlintPrime SA SBS-SA (Optional) SBS-SA SBS-SA -555.0
C-99. Structural concrete FlintPrime (ASTM D41) SBS-SA (Optional) SBS-SA SBS-SA -630.0
Hybrid Systems:
C-100. Structural concrete FlintPrime SA Flintlastic Ultra Glass SA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5
C-101. Structural concrete FlintPrime (ASTM D41) Flintlastic Ultra Glass SA (Optional) SBS-AA SBS-AA -135.0
C-102. Structural concrete FlintPrime (ASTM D41) Black Diamond Base Sheet (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -150.0
C-103. Structural concrete FlintPrime (ASTM D41) Flintlastic Ultra Glass SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -322.5
C-104. Structural concrete FlintPrime (ASTM D41) Black Diamond Base Sheet (Optional) BP-AA,SBS-AA SBS-AA -240.0
C-105. Structural concrete FlintPrime (ASTM D41) BP-AA, SBS-AA SBS-SA-H SBS-AA, SBS-TA, APP-TA -635.0
Conventional Systems:
C-106. Structural concrete FlintPrime (ASTM D41) APP-TA (Optional) APP-TA APP-TA -420.0
C-107. Structural concrete FlintPrime (ASTM D41) SBS-TA (Optional) SBS-TA SBS-TA -542.5
C-108. Structural concrete FlintPrime (ASTM D41) BP-AA, SBS-AA (Optional) BP-AA,SBS-AA, SBS-TA or APP-TA SBS-AA,SBS-TAor APP-TA -635.0
Cold-Applied Systems:
C-109. Structural concrete FlintPrime (ASTM D41) SBS-CAl (Optional) SBS-CAl SBS-CAl -262.5
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 37 of 57
TRINITY ERDTABLE 4A: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (Tear-Off)
SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Lightweight Concrete
(Note 13)
Base Insulation Layer Coverboard Roof Cover (Note 14) MDP
(psf)Type Attach Type Attach Base Ply Cap
Self-Adhering Systems:
LWC-l ConcreteMin. 200 psi, min. 2-inch
Elastizell
Min. 1.5-inch ACFoam II,
FlintBoard, ENRGY3 or H-ShieldA-PD, 6-
inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof BoardA-PD, 6-
inch o.c.SBS-SA (Optional) SBS-SA SBS-SA -172.5
LWC-2 ConcreteMin. 200 psi, min. 2-inch
Elastizell
Min. 1.5-inch ACFoam II,
FlintBoard, ENRGY3 or Multi-MaxFA3
A-PD, 6-
inch o.c.
Min. 0.25-inch Dens Deck
primed with FlintPrime or
FlintPrime SA
A-PD, 6-
inch o.c.SBS-SA (Optional) SBS-SA SBS-SA -187.5
LWC-3 ConcreteMin. 200 psi, min. 2-inchElastizell
Min. 1.5-inch ACFoam II,
FlintBoard ISO or ENRGY 3OB500
Min. 0.25-inch Dens Deck
primed with FlintPrime orFlintPrime SA
OB500 SBS-SA (Optional) SBS-SA SBS-SA -150.0
LWC-4 ConcreteMin. 200 psi, min. 2-inch
Elastizell
Min. 1.5-inch ACFoam II,
FlintBoard, ENRGY 3 or H-ShieldOB500
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof BoardOB500 SBS-SA (Optional) SBS-SA SBS-SA -172.5
LWC-5 ConcreteMin. 200 psi, min. 2-inch
Celcore, Elastizell or Celcore
Min. 1.0-inch ISO 9S+ GL, H-Shield,
H-Shield CG, ENRGY3 or min. 1.3-inch ACFoam III, Min. 1.5-inch
Multi-Max FA3 or Ultra-Max
CR-20Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof BoardCR-20 SBS-SA (Optional) SBS-SA SBS-SA -172.5
LWC-6 ConcreteMin. 200 psi, min. 2-inch
Celcore, Elastizell or Celcore
Min. 1.0-inch ISO 95+ GL, H-Shield,H-Shield CG, ENRGY3 or min. 1.3-
inch ACFoam III, Min. 1.5-inch
Multi-Max FA3 or Ultra-Max
CR-20
Min. 0.25-inch Dens Deck
primed with FlintPrime or
FlintPrime SA
CR-20 SBS-SA (Optional) SBS-SA SBS-SA -180.0
CONVENTIONAL SYSTEMS:
LWC-7 ConcreteMin. 200 psi, min. 2-inch
Elastizell
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3 or H-Shield
A-PD
6-inch
o.c.
Min. 0.5-inch Structodek
High Density Fiberboard orMin. 0.25-inch Dens Deck
A-PD
6-inch
o.c.
BP-AA or SBS-
AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-187.5
LWC-8 ConcreteMin. 200 psi, min. 2-inch
Elastizell
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3 or H-Shield
A-PD, 6-
inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof BoardA-PD, 6-
inch o.c.
BP-AA or SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-217.5
LWC-9 ConcreteMin. 200 psi, min. 2-inch
Elastizell
Min. l.S-inch ACFoam II or
FlintBoard ISO.OBS00
Min. 0.25-inch Dens Deck
or Dens Deck PrimeOB500
BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-150.0
LWC-10 ConcreteMin. 200 psi, min. 2-inch
Elastizell
Min. 1.5-inch ACFoam II or
FlintBoard ISO.OB500
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof BoardOB500 SBS-TA (Optional) SBS-TA SBS-TA -180.0
LWC-11 ConcreteMin. 200 psi, min. 2-inch
Elastizell
Min. 2-inch ACFoam II, FlintBoardISO, ENRGY 3 or H-Shield
OB500Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof BoardOB500
BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-225.0
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017)FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19
Revision 20: 09/14/2017
Appendix 1, Page 38 of 57
TRINITY ERDTABLE 4A: LIGHTWEIGHT CONCRETE DECKS-NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEMTYPE A-l: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Lightweight Concrete
(Note 13)
Base Insulation Layer Coverboard Roof Cover (Note 14) MDP
(psflType Attach Type Attach Base Ply Cap
LWC-12 ConcreteMin. 200 psi, min. 2-inch
Celcore, Elastizell or Celcore
Min. 1.0-inch ISO 95+ GL, H-Shield,H-Shield CG, ENRGY 3 or min. 1.3-
inch ACFoam III, Min. 1.5-inch
Multi-Max FA3 or Ultra-Max
CR-20
Min. 0.5-inch Structodek
High Density Fiberboard orDuraBoard (homogeneous)or min. 1.5-inch
FescoBoard (laminated)
CR-20BP-AA or SBS-
AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-180.0
LWC-13 ConcreteMin. 200 psi, min. 2-inchCelcore, Elastizell or Celcore
Min. 1.0-inch ISO 95+ GL, H-Shield,H-Shield CG, ENRGY3 or min. 1.3-
inch ACFoam III, Min. 1.5-inchMulti-Max FA3 or Ultra-Max
CR-20
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Boardor Dens Deck or Dens Deck
Prime
CR-20
BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-180.0
Cold Appued Systems:
LWC-14
Min. 22 ga.
steel at max
5 ft spans orstructural
concrete
Min. 350 psi, min 2-inchRange II Elastizell LightweightInsulating Concrete with ZellFibers.
Min. l.S-inch H-Shield CG
OB500,
6-inch
o.c.
(Optional) Additionallayers of base insulation
OB500,
6-inch
o.c.
BP-CA3 or
SBS-CA3
(Optional) BP-CA3orSBS-CA3
SBS-CA3 -60.0
LWC-15
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 350 psi, min 2-inchRange II Elastizell LightweightInsulating Concrete with ZellFibers. When walkable,
attach LWC with Flintfast #14
and Flintfast 3" Round Plates
at 1 per 8 ft2 throughto thestructural deck.
Min. 1.5-inch H-Shield CG
OB500,
6-inch
o.c.
(Optional) Additionallayers of base insulation
OB500,
6-inch
o.c.
BP-CA3 or
SBS-CA3
(Optional) BP-CA3or SBS-CA3
SBS-CA3 -67.5
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 39 of 57
TRINITY erdTABLE 4B: UGHTWEIGHT CONCRETE DECKS- NEW CONSTRUCTION or REROOF (Tear-Off)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
LWC
(Note 13)
Anchor Sheet Insulation Roof Cover (Note 14)MDP (psf)
Type Fasteners Attach Base Top Attach Base Ply Cap
LWC-16
Min. 22 ga.
steel or
structural
concrete deck.
Minimum 350 psi,
minimum 2-inch
Elastizell cellular LWIC
Yosemite
Venting
Base
ES FM-90
Base Ply
Fasteners
7-inch o.c. at the 4-inch
side lap and 7-inch o.c.at two, equally spaced,staggered rows in thecenter of the sheet
Min. 1.5-
inch
ACFoam II
(Optional)Additional
layers baseinsulation
Hot
asphalt
BP-AA3,18-
inch grid
(Optional)BP-AA,
SBS-AA
SBS-AA -37.5*
LWC-17
Min. 22 ga.
steel or
structural
concrete deck.
Minimum 350 psi,
minimum 2-inch
Approved or existingcellular LWIC Wore: To
qualify the LWIC underthis assembly, thesubjectfastener shallachieve an averagewithdrawal of88 Ibfwhen tested per TAS105 or ANSI/SPRIFX-1.
Yosemite
Venting
Base
ES Twin-Loc
Nails
9-inch o.c. at the 4-inch
side lap and 9-inch o.c.
at two, equally spaced,staggered rows in thecenter of the sheet
Min. l.S-
inch
ACFoam II
(Optional)Additional
layers base
insulation
Hot
asphalt
BP-AA4,18-
inch o.c.
(Optional)BP-AA,
SBS-AA
SBS-AA -60.0
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19
Revision 20: 09/14/2017Appendix 1, Page 40 of 57
TRINITY ERD
TABLE 4C: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear-Off)SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)Lightweight Concrete (Note 13)
Base Sheet Roof Cover (Note 14)MDP (psf)
Type Fasteners Attach Ply Cap
Self-Adhering Systems:
LWC-18
Min. 22 ga.
steel at max
5 ft spans orstructural
concrete
Min. 300 psi, min. 2-inch Approved cellularlightweight insulating concrete. Note: Toqualifythe LWICunder this assembly, a 1.8-inch TrufastTwin Loc-Nail Assembled Fastener shall achieve an
average withdrawal of 73 Ibf when tested per TAS105 or ANSI/SPRI FX-1
Flintlastic SA NailBase
Trufast Twin Loc-Nail
Assembled Fastener
(min. 1.8")
7-inch o.c. at the min. 2-inch lap and 7-incho.c. in two (2), equally spaced, staggeredcenter rows; Stress plates shall be primedwith FlintPrime (ASTM D41) primer or
FlintPrime SA
SBS-SA SBS-SA -60.0
LWC-19
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 300 psi, min. 2-inch Approved cellularlightweight insulating concrete. Wore: Toqualifythe LWICunder this assembly, a 1.8-inch TrufastTwin Loc-Nail Assembled Fastener shall achieve an
average withdrawal of 93 Ibf when tested per TAS105 or ANSI/SPRIFX-1
Flintlastic SA NailBase
Trufast Twin Loc-Nail
Assembled Fastener
(min. 1.8")
9-inch o.c. at the min. 2-inch lap and 9-incho.c. in two (2), equally spaced, staggeredcenter rows; Stress plates shall be primedwith FlintPrime (ASTM D41) primer or
FlintPrime SA
SBS-SA SBS-SA -60.0
Hybrid Systems:
LWC-20
Min. 26 ga.
steel at max
5 ft spans orstructural
concrete
Min. 200 psi, min 2-inch Range II ElastizellLightweight Insulating Concrete.
Glasbase; FlexiglasBase; Flintlastic Base
20; AllWeather/Empire Base or PolySMS Base
Trufast FM-90 Base
Sheet Fasteners or
Trufast Twin Loc-Nail
Assembled Fasteners
(1.8 inch)
754-inch o.c. at the 4-inch lap and 7J4-incho.c. in two (2), equally spaced, staggeredcenter rows
SBS-SA-H
SBS-AA,
SBS-TA or
APP-TA
-30.0
LWC-21
Min. 22 ga.
steel at max
5 ft spans orstructural
concrete
Min. 200 psi, min 2-inch Range II ElastizellLightweight Insulating Concrete.
Glasbase; Flexiglas
Base; Flintlastic Base
20; All Weather/Empire Base or PolySMS Base
Trufast FM-90 Base
Sheet Fasteners or
Trufast Twin Loc-Nail
Assembled Fasteners
(1.8 inch)
7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows
SBS-SA-H
SBS-AA,
SBS-TA or
APP-TA
-45.0
LWC-22
Min. 22 ga.
steel at max
5 ft spans orstructural
concrete
Min. 300 psi, min. 2-inch Approved cellularlightweight insulatingconcrete. Note: Toqualifythe LWIC under this assembly, a 1.8-inch TrufastTwin Loc-Nail Assembled Fastener shall achieve an
average withdrawal of 88 Ibfwhen tested per TAS105 or ANSI/SPRIFX-1
Glasbase; FlexiglasBase; Flintlastic Base20; All Weather/
Empire Base
Trufast Twin Loc-Nail
Assembled Fastener
(min. 1.8")
9-inch o.c. at the 4-inch lap and 9-inch o.c. intwo (2), equally spaced, staggered centerrows
SBS-SA-H
SBS-AA,
SBS-TA or
APP-TA
-60.0
LWC-23
Min. 22 ga.
steel at max
5 ft spans or
structural
concrete
Min. 350 psi, min. 3-inch Approved cellularlightweight insulating concrete. Note: Toqualifythe LWICunder this assembly, a 1.8-inch TrufastTwin Loc-Nail Assembled Fastener shall achieve an
average withdrawal of 97 Ibfwhen tested per TAS105 or ANSI/SPRIFX-1
Flexiglas Base;Flintlastic Base 20 or
Poly SMS Base
Trufast FM-90 Base
Sheet Fasteners
7-inch o.c. at the 4-inch lap and 10-inch o.c.
in two (2), equally spaced, staggered center
rows
SBS-SA-H
SBS-AA,
SBS-TA or
APP-TA
-67.5
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 41 of 57
TRINITY ERDTABLE4C: LIGHTWEIGHTCONCRETEDECKS - NEW CONSTRUCTION or REROOF(Tear-Off)
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)Lightweight Concrete (Note 13)
Base Sheet Roof Cover (Note 14)MDP (psf)
Type Fasteners Attach Ply Cap
LWC-24
Min. 22 ga.
steel at max
5 ft spans orstructural
concrete
Min. 300 psi, min. 2-inch Approved cellularlightweight insulating concrete. Note: Toqualifythe LWIC under this assembly, a 1.8-inch TrufastTwin Loc-Nail Assembled Fastener shall achieve an
average withdrawal of 110 Ibf when tested per TAS105 or ANSI/SPRIFX-1
Poly SMS Base; UltraPoly SMS Base
Trufast Twin Loc-Nail
Assembled Fastener
(min. 1.8")
9-inch o.c. at the 4-inch lap and 9-inch o.c. in
two (2), equally spaced, staggered centerrows
SBS-SA-H
SBS-AA,
SBS-TA or
APP-TA
-75.0
Conventional Systems :
LWC-25
Min. 26 ga.
steel at max
5 ft spans orstructural
concrete
Min. 200 psi, min 2-inch Range II ElastizellLightweight Insulating Concrete.
Glasbase; FlexiglasBase; Flintlastic Base
20; All Weather/Empire Base; PolySMS Base; Yosemite
Trufast FM-90 Base
Sheet Fasteners or
Trufast Twin Loc-Nail
Assembled Fasteners
(1.8 inch)
7/j-inch o.c. at the 4-inch lap and 754-incho.c. in two (2), equally spaced, staggeredcenter rows
(Optional)
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-30.0
LWC-26
Min. 26 ga.
steel at max
5 ft spans orstructural
concrete
Min. 200 psi, min 2-inch Range II ElastizellLightweight Insulating Concrete.
Flintlastic APP Base TTrufast FM-90 Base
Sheet Fasteners
7J4-inch o.c. at the 4-inch lap and 734-incho.c. in two (2), equally spaced, staggeredcenter rows
(Optional)APP-TA
APP-TA -30.0
LWC-27
Min. 22 ga.
steel at max
5 ft spans orstructural
concrete
Min. 200 psi, min 2-inch Range II ElastizellLightweight Insulating Concrete.
Glasbase; FlexiglasBase; Flintlastic Base
20; All Weather/
Empire Base; Poly
SMS Base; Yosemite
Trufast FM-90 Base
Sheet Fasteners or
Trufast Twin Loc-Nail
Assembled Fasteners
(1.8 inch)
7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows
(Optional)
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0
LWC-28
Min. 22 ga.
steel at max
5 ft spans orstructural
concrete
Min. 200 psi, min 2-inch Range II ElastizellLightweight Insulating Concrete.
Flintlastic APP Base TTrufast FM-90 Base
Sheet Fasteners
7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows
(Optional)
APP-TAAPP-TA -45.0
LWC-29
Min. 22 ga.
steel at max
5 ft spans orstructural
concrete
Min. 250 psi, min 2-inch Mearlcrete.
Glasbase; FlexiglasBase; Flintlastic Base
20; All Weather/Empire Base; PolySMS Base; Yosemite
OMG CR Base Ply
Fasteners (1.7)
7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows
(Optional)BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-45.0
LWC-30
Min. 22 ga.
steel at max
5 ft spans orstructural
concrete
Min. 250 psi, min 2-inch Mearlcrete. Poly SMS BaseOMG CR Base PlyFasteners (1.7)
7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows
(Optional)BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-52.5
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666thEDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19
Revision 20: 09/14/2017Appendix 1, Page 42 of 57
TRINITY ERDTABLE 4C: UGHTWEIGHT CONCRETE DECKS - NEWCONSTRUCTION OR REROOF (Tear-Off)
SYSTEM TYPE E: MECHANICALLYATTACHED BASE SHEET, BONDED ROOFCOVER
System
No.
Deck
(Note 1)Lightweight Concrete (Note 13)
Base Sheet Roof Cover (Note 14)MDP (psf)
Type Fasteners Attach Ply Cap
LWC-31
Min. 22 ga.
steel at max
5 ft spans orstructural
concrete
Min. 300 psi, min 2-inch Mearlcrete.
Glasbase; Flexiglas
Base; Flintlastic Base
20; All Weather /Empire Base; PolySMS Base; Yosemite
OMG CR Base Ply
Fasteners (1.7)
7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered center
rows
(Optional)BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-52.5
LWC-32
Min. 22 ga.
steel at max
5 ft spans orstructural
concrete
Concrecel Bonding Agent on deck; Min. 300 psi, min2%-inch Concrecel Concrete.
Glasbase; FlexiglasBase; Flintlastic Base20; AllWeather/Empire Base; PolySMS Base; Yosemite
OMG CR Base PlyFasteners (1.7)
7-inch o.c. at the 3-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows
(Optional)
BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-52.5
LWC-33
Min. 22 ga.
steel at max
5 ft spans orstructural
concrete
Min. 300 psi, min. 2-inch Approved cellularlightweight insulating concrete. Note: To qualifythe LWIC under this assembly, a 1.8-inch TrufastTwin Loc-Nail Assembled Fastener shall achieve an
average withdrawal of 88 Ibfwhen tested per TAS105 or ANSI/SPRIFX-1
Glasbase; Flexiglas
Base; Flintlastic Base
20; AllWeather/Empire Base;
Yosemite
Trufast Twin Loc-Nail
Assembled Fastener
(min. 1.8")
9-inch o.c. at the 4-inch lap and 9-inch o.c. intwo (2), equally spaced, staggered centerrows
(Optional)BP-AA,
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
LWC-34
Min. 22 ga.,
type B steelat max. 5 ft
spans
structural
concrete
Min. 300 psi, min 2-inch Celcore MFCellularConcrete with Celcore HS Rheology ModifyingAdmixture. After setting to support foot traffic,Celcore PVA Curing Compound is applied.
AllWeather/Empire
Base; Flintlastic Base
20; Poly SMS Base
Trufast FM-90 Base
Sheet Fasteners
9-inch o.c. at 4-inch laps and 12-inch o.c. intwo (2), equally spaced, staggered centerrows
(Optional)BP-AA,
SBS-AA or
SBS-TA-F
SBS-AA or
SBS-TA-F-60.0
LWC-35
Min. 22 ga.
steel at max
5 ft spans orstructural
concrete
Min. 300 psi, min. 2-inch Approved cellularlightweightinsulatingconcrete. Note:To qualifythe LWICunder this assembly, a 1.8-inch TrufastTwin Loc-Nail Assembled Fastener shall achieve an
average withdrawal of 77 Ibfwhen tested per TAS105 or ANSI/SPRI FX-1
Glasbase; FlexiglasBase; Flintlastic Base
20; AllWeather/Empire Base;Yosemite
Trufast Twin Loc-Nail
Assembled Fastener
(min. 1.8")
7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows
BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-67.5
LWC-36
Min. 22 ga.
steel at max
5 ft spans orstructural
concrete
Min. 350 psi, min. 3-inch Approved cellularlightweightinsulatingconcrete. Wore: To qualifythe LWICunder this assembly, a 1.8-inch TrufastTwin Loc-Nail Assembled Fastener shall achieve an
average withdrawal of 97 Ibfwhen tested per TAS105 or ANSI/SPRI FX-1
Flexiglas Base;Flintlastic Base 20;
Poly SMS Base;
Yosemite
Trufast FM-90 Base
Sheet Fasteners
7-inch o.c. at the 4-inch lap and 10-inch o.c.in two (2), equally spaced, staggered centerrows
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-67.5
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6thEDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 43 of 57
System
No.
LWC-37
LWC-38
Deck
(Note 1)
Min. 22 ga.
steel at max
5 ft spans orstructural
concrete
Min. 22 ga.
steel at max
5 ft spans orstructural
concrete
Cold Appued Systems:
LWC-39
LWC-40
LWC-41
Min. 22 ga.steel at max
5 ft spans orstructural
concrete
Min. 22 ga.
steel at max
5 ft spans
Structural
concrete
TABLE 4C: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear-Off)SYSTEMTYPEE: MECHANICALLY ATTACHED BASESHEET, BONDED ROOFCOVER
Lightweight Concrete (Note 13)
Min. 300 psi, min. 2-inch Approved cellularlightweight insulatingconcrete. Note: Toqualifythe LWIC under thisassembly, a 1.8-inchTrufastTwin Loc-Nail Assembled Fastener shall achieve anaverage withdrawal of 110 Ibfwhen tested per TAS105 or ANSI/SPRIFX-1
Min. 300 psi, min 2-inch Celcore Cellular Concrete.After setting to support foot traffic, Celcore PVACuring Compound is applied.
Min. 350 psi, min 2-inch Range IIElastizellLightweight Insulating Concrete with Zell Fibers.
Min. 350 psi, min 2-inch Range II ElastizellLightweight Insulating Concrete with Zell Fibers.
Min. 350 psi, min 2-inch Range II ElastizellLightweight Insulating Concrete with Zell Fibers.
Type
Poly SMS Base; UltraPoly SMS Base
Glasbase; FlexiglasBase; Flintlastic Base
20; All Weather/
Empire Base; Poly
SMS Base; Yosemite
Flintlastic Base 20;
Poly SMS Base
Glasbase; FlexiglasBase; Poly SMS Base
Glasbase; FlexiglasBase; Poly SMS Base
Base Sheet
Fasteners
Trufast Twin Loc-Nail
Assembled Fastener
(min. 1.8")
Trufast FM-90 Base
Sheet Fasteners
Trufast FM-90 Base
Sheet Fasteners
Trufast FM-90 Base
Sheet Fasteners
Trufast FM-90 Base
Sheet Fasteners
Attach
9-inch o.c. at the 4-inch lap and 9-inch o.c. intwo (2), equally spaced, staggered centerrows
7-inch o.c. at the 3-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows
7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows
7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows
7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows
TRINITY ERD
Roof Cover (Note 14)
Ply
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
BP-AA or
SBS-AA
(Optional)BP-CA2 or
SBS-CA2
(Optional)BP-CA3 or
SBS-CA3
(Optional)BP-CA3 or
SBS-CA3
Cap
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
SBS-CA2
SBS-CA3
SBS-CA3
MDP (psf)
-75.0
-75.0
-45.0
-52.5
-60.0
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666,M EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19
Revision 20: 09/14/2017Appendix 1, Page 44 of 57
TABLE5A
:C
EMEN
TITIOU
SW
OO
DFIBER
DECKS
-N
EW
CO
NSTRU
CTIO
Nor
REROO
F(T
ear-Off)
SYST
EM
TY
PE
A-l:
BO
ND
ED
INSU
LA
TIO
N,
BO
ND
ED
RO
OF
CO
VE
R
Syste
m
No
.
Deck
(No
te1)
Ba
seIn
sula
tion
La
yer
Typ
e
Self-A
dh
erin
gS
yste
ms:
CW
F-1
.T
ectu
m
CW
F-2
.T
ectu
m
Min.
1.5-inchFlintB
oardISO
,AC
FoamII,EN
RG
Y3
orM
ulti-
Max
FA
3
Min.
1.0-inchISO
95+G
L,H
-Shield,H
-ShieldC
G,EN
RG
Y3
orm
in.1.3-inch
AC
FoamIII,M
in.l.S
-inchM
ulti-Max
FA3
or
Ultra
-Max
Co
nven
tion
al
Syste
ms:
CW
F-3
.T
ectu
m
CW
F-4
.T
ectu
m
CW
F-5
.T
ectu
m
CW
F-6
.T
ectu
m
Min.
1.5-inchF
lintBoard
ISO,A
CFoam
II,ENR
GY
3or
Multi-
Max
FA
3
Min.
1.5-inchF
lintBoard
ISO,A
CFoam
II,ENR
GY
3or
Multi-
Max
FA
3
Min.
1.0-inchISO
95
+G
L,H
-Shield,
H-S
hieldC
G,EN
RG
Y3
orm
in.1.3-inch
AC
FoamIII,M
in.1.5-inch
Multi-M
axFA
3
or
Ultra
-
Min.
1.0-inchISO
95+G
L,H
-Shield,H
-ShieldC
G,EN
RG
Y3
or
min.
1.3-inchA
CFoam
III,Min.
1.5-inchM
ulti-Max
FA3
or
Ultra
-Max
Atta
ch
OB
50
0
CR
-20
OB
50
0
OB
50
0
CR
-20
CR
-20
To
pIn
sula
tion
Layer
Typ
e
Min.
0.25-inchD
ensD
eckp
rimed
with
Flin
tPrim
eo
rF
lintP
rime
SA;o
rSE
CU
RO
CK
Gypsum
-FiberR
oofBoard
Min.
0.25-inchD
ensD
eckp
rimed
with
Flin
tPrim
eo
rF
lintP
rime
SA;o
rSE
CU
RO
CK
Gypsum
-Fiber
RoofB
oard
Min.
0.5-inchS
tructo
dek
High
Density
Fib
erb
oard
Min.
0.25-inchSEC
UR
OC
KG
ypsum-F
iberR
oo
fB
oard
or
Den
sD
ecko
rD
ens
Deck
Prim
e
Min.
0.5-inchS
tructo
dek
High
Density
Fiberboard
orD
uraB
oard(hom
ogeneous)or
min.
1.5-inchF
escoBoard
(laminated)
Min.0.25-inch
SECU
RO
CK
Gypsum
-Fiber
Ro
of
Bo
ardo
rD
ens
Deck
or
Den
sD
eck
Prim
e
Atta
ch
OB
50
0
CR
-20
OB
50
0
OB
50
0
CR
-20
CR
-20
Exterior
Research
andD
esign,LLC.d/b
/aT
rinity|ERD
Certific
ate
of
Au
tho
rizatio
n#
95
03
Prep
aredby:
Ro
bert
Niem
inen,P
E-59166
6™ED
ITION
(2017)FBCN
ON
-HVH
ZEVALU
ATION
CertainT
eedF
lintlastic*M
odifiedB
itum
enR
oo
fSystem
s;(610)
651-5847
Ba
se
SB
S-S
A
SB
S-S
A
BP
-AA
or
SB
S-A
A
BP-A
A,SB
S-
AA
,SB
S-TA
or
AP
P-T
A
BP
-AA
or
SB
S-A
A
BP-A
A,
SBS-
AA
,SB
S-TA
or
AP
P-T
A
TR
INIT
YERD
Ro
ofC
over(N
ote
14)
Ply
(Optional)
SBS-SA
(Optional)
SBS-SA
(Optional)
BP-A
A,
SBS-A
A,
SBS-T
Ao
r
AP
P-T
A
(Optional)
BP-A
A,
SBS-A
A,SB
S-TA
or
AP
P-T
A
(Optional)
BP-A
A,
SBS-A
A,SB
S-TA
or
AP
P-T
A
(Optional)
BP-A
A,
SBS-A
A,
SBS-T
Ao
r
AP
P-T
A
Cap
SB
S-S
A
SB
S-S
A
SBS-A
A,
SB
S-T
Ao
r
AP
P-T
A
SBS-A
A,
SB
S-T
Ao
r
AP
P-T
A
SBS-A
A,
SB
S-T
Ao
r
AP
P-T
A
SBS-A
A,
SB
S-T
Ao
r
AP
P-T
A
MD
P(psf)
-45
.0*
-52
.5
-45
.0*
-45
.0*
-52
.5
-52
.5
Evaluation
Report
3520.03.04-R20
forF
12533-R19
Revision
20:0
9/1
4/2
01
7
Appendix
1,Page45
of57
TRINITY ERDTABLE 5B: CEMENTITIOUS WOOFFIBER DECKS - NEWCONSTRUCTION or REROOF (Tear-Off)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVERSystem
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14)MDP (psf)Type Fasteners Attach Type Attach Type Attach Base Ply Cap
Hybrid Systems:
CWF-7. Tectum
Glasbase; FlexiglasBase; Flintlastic Base
20; All Weather/
Empire Base; Yosemite
Trufast Twin
Loc-Nail
Assembled
Fastener
(min. 1.8")
7-inch o.c. at the 4-
inch lap and 7-incho.c. in two (2),
equally spaced,staggered center
rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3 or Multi-
Max FA3
HA None N/ASBS-SA-
H
(Optional)
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
Conventional Systems:
CWF-8. Tectum
Glasbase; FlexiglasBase; Flintlastic Base
20; All Weather/Empire Base; Yosemite
Trufast Twin
Loc-Nail
Assembled
Fastener
(min. 1.8")
7-inch o.c. at the 4-
inch lap and 7-incho.c. in two (2),
equally spaced,staggered centerrows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3 or Multi-
Max FA3
HA
Min. 0.75-inch
FescoBoard
(homogeneous) or min.0.5-inch Structodek
High Density Fiberboard
HA
BP-AA
or SBS-
AA
(Optional)
BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-60.0
TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS - NEWCONSTRUCTION, REROOF (Tear-Off) or RECOVERSYSTEM TYPEC: MECHANICALLY ATTACHED INSULATION, BONDEDROOFCOVER
System
No.
Deck
(Note 1)Base Insulation Layer(s)
Top Insulation Layer Roof Cover (Note 14)MDP (psf)Type Fasteners Attach Base Ply Cap
CWF-9. Tectum
(Optional) One or morelayers, any combination,loose laid
Min. 0.5-inch Structodek HighDensity Fiberboard RoofInsulation
OMG Polymer GypTec with 3"GypTec Plate
1 per 2 ft* BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
CWF-10. Tectum
(Optional) One or morelayers, any combination,loose laid
Min. 0.25-inch Dens Deck or
Dens Deck Prime
OMG Polymer GypTec with 3"GypTec Plate
1 per 1.78ft'BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
CWF-11. Tectum
(Optional) One or morelayers, any combination,loose laid
Min. 0.5-inch Structodek HighDensity Fiberboard Roof
Insulation
Trufast Twin Loc-Nail
Assembled Fasteners
(minimum 1-inch embedmentinto deck)
1 per 2 ft' BP-AA or SBS-
AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
CWF-12. Tectum
(Optional) One or morelayers, any combination,loose laid
Min. 0.25-inch Dens Deck or
Dens Deck Prime or
SECUROCK Gypsum-FiberRoof Board
Trufast Twin Loc-Nail
Assembled Fasteners
(minimum 1-inch embedmentinto deck)
1 per 2 ft2BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
ExteriorResearch and Design,LLC. d/b/a Trinity| ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 46 of 57
TRINITY ERD
TABLE5D: CEMENTITOUSWOOD FIBER DECKS - NEW CONSTRUCTIONOR REROOF(Tear-Off)
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 14)MDP (psf)
Base Fasteners Attach Ply Cap
Self-Adhering Systems:
CWF-13. Tectum Flintlastic SA NailBase
Trufast Twin Loc-Nail
Assembled Fastener (min.
1.8")
7-inch o.c. at the 4-inch lap and 7-inch o.c. in two(2), equally spaced, staggered center rows
SBS-SA SBS-SA -60.0
Conventional Systems:
CWF-14. Tectum All Weather / Empire Base; YosemiteTrufast Insuldeck Loc-Nail Base
Sheet Fastener
9-inch o.c. at the 4-inch lap and 12-inch o.c. in two(2), equally spaced, staggered center rows
BP-AA or SBS-AA SBS-AA -30.0*
CWF-15. Tectum All Weather / Empire Base; YosemiteTrufast Insuldeck Loc-Nail Base
Sheet Fastener
734-inch o.c. at the 4-inch lap and 7K-inch o.c. intwo (2), equally spaced, staggered center rows
BP-AA or SBS-AA SBS-AA -45.0*
CWF-16. TectumGlasbase; FlexiglasBase; All Weather /Empire Base; Yosemite
Simplex Turbo Tube-Lok9-inch o.c. at the 4-inch lap and 12-inch o.c. in two(2), equally spaced, staggered center rows
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
CWF-17. TectumGlasbase; Flexiglas Base; Flintlastic Base20 or All Weather / Empire Base; Yosemite
Trufast Twin Loc-Nail
Assembled Fastener (min.
1.8")
7-inch o.c. at the 4-inch lap and 7-inch o.c. in two
(2), equally spaced, staggered center rowsBP-AA or SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-67.5
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 47 of 57
TRINITY erdTABLE 6A: GYPSUM DECKS-REROOF (Tear-Off)
SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER
System
No.Deck
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14)MDP (psf)
Type Attach Type Attach Base Ply Cap
Self-Adhering Systems:
G-l.
Existing soundgypsum or
gypsum plank
Min. l.S-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield
M-OSFAMin. 0.25-inch SECUROCK
Gypsum-Fiber Roof BoardM-OSFA SBS-SA (Optional) SBS-SA SBS-SA -172.5
G-2.
Existing soundgypsum or
gypsum plank
Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 orMulti-Max FA
M-OSFAMin. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SAM-OSFA SBS-SA (Optional) SBS-SA SBS-SA -192.5
G-3.
Existing soundgypsum or
gypsum plankMin. 1.5-inch ACFoam II, FlintBoard ISO or ENRGY3 OB500
Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA
or SECUROCK Gypsum-Fiber RoofBoard
OB500 SBS-SA (Optional) SBS-SA SBS-SA -135.0
G-4.
Existing soundgypsum or
gypsum plank
Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,
ENRGY3 or min. 1.3-inch ACFoam III, Min. 1.5-inchMulti-Max FA3 or Ultra-Max
CR-20Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof BoardCR-20 SBS-SA (Optional) SBS-SA SBS-SA -172.5
G-5.
Existing soundgypsum or
gypsum plank
Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,ENRGY3 or min. 1.3-inch ACFoam III, Min. 1.5-inchMulti-Max FA3 or Ultra-Max
CR-20Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SACR-20 SBS-SA (Optional) SBS-SA SBS-SA -192.5
Conventional Systems:
G-6.
Existing soundgypsum or
gypsum plank
Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY3 orH-Shield
M-OSFAMin. 0.5-inch Structodek High
Density FiberboardM-OSFA
BP-AA or SBS-
AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-127.5
G-7.
Existing soundgypsum or
gypsum plank
Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY3 or
H-ShieldM-OSFA Min. 0.25-inch Dens Deck M-OSFA
BP-AA or SBS-
AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-232.5
G-8.
Existing sound
gypsum or
gypsum plank
Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY3 or
H-ShieldM-OSFA
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof BoardM-OSFA
BP-AA or SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-202.5
G-9.
Existing sound
gypsum or
gypsum plank
Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY3 orH-Shield
OB500Min. 0.5-inch Structodek HighDensity Fiberboard
OB500BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-120.0
G-10.
Existing sound
gypsum or
gypsum plank
Min. l.S-inch ACFoam II, FlintBoard ISO, ENRGY3 or
H-ShieldOB500
Min. 0.25-inch Dens Deck, Dens
Deck Prime or SECUROCK
Gypsum-Fiber Roof BoardOB500
BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-135.0
G-ll.
Existing soundgypsum or
gypsum plank
Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,ENRGY3 or min. 1.3-inch ACFoam III, Min. 1.5-inchMulti-Max FA3 or Ultra-Max
CR-20Min. 0.25-inch Dens Deck or Dens
Deck PrimeCR-20 SBS-TA (Optional) SBS-TA SBS-TA -180.0
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017)FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19
Revision 20:09/14/2017Appendix 1, Page 48 of 57
System
No.
G-12.
G-13.
G-14.
G-15.
Deck
Existing soundgypsum or
gypsum plank
Existing soundgypsum or
gypsum plank
Existing soundgypsum or
gypsum plank
Existing soundgypsum or
gypsum plank
TABLE6A: GYPSUM DECKS- REROOF(Tear-Off)
SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer
Type
Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,ENRGY3 or min. 1.3-inch ACFoam III, Min. 1.5-inch
Multi-Max FA3 or Ultra-Max
Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,ENRGY 3 or min. 1.3-inch ACFoam III,Min. 1.5-inchMulti-Max FA3 or Ultra-Max
Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,ENRGY 3 or min. 1.3-inch ACFoam III,Min. 1.5-inchMulti-Max FA3 or Ultra-Max
Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,ENRGY3 or min. 1.3-inch ACFoam III, Min. 1.5-inch
Multi-Max FA3 or Ultra-Max
Attach
CR-20
CR-20
CR-20
CR-20
Top Insulation Layer
Type
Min. 0.5-inch Structodek High
Density Fiberboard or DuraBoard(homogeneous) or min. 1.5-inchFescoBoard (laminated)
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Min. 0.25-inch Dens Deck
Attach
CR-20
CR-20
CR-20
CR-20
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6thEDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Base
BP-AA or SBS-
AA
BP-AA or SBS-
AA
SBS-TA or
APP-TA
BP-AA or SBS-
AA
TRINITY ERD
Roof Cover (Note 14)
Ply
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
(Optional) SBS-TAor APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
Cap
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
MDP (psf)
-180.0
-225.0
-232.5
-240.0
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 49 of 57
TRINITY ERDTABLE 6B: GYPSUM DECKS-REROOF(Tear-Off)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVERSystem
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) MDP
(psf)Type Fasteners Attach Type Attach Type Attach Base Ply CapHybrid Systems:
G-16.
Existing sound
gypsum or
gypsum plank
Glasbase; FlexiglasBase; Flintlastic
Base 20; All
Weather/EmpireBase; Yosemite
Trufast Twin
Loc-Nail
Assembled
Fastener
(min. 1.8")
7-inch o.c. at the 4-
inch lap and 7-inch
o.c. in two (2),equally spaced,staggered centerrows
Min. l.S-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3 or Multi-
Max FA3
HA None N/ASBS-SA-
H
(Optional)SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
Conventional Systems:
G-17.
Existing sound
gypsum or
gypsum plank
All Weather/
Empire Base;
Yosemite
Trufast FM-75
or FM-90
Base Sheet
Fastener
9-inch o.c. at the 4-
inch lap and 18-incho.c. in two (2),
equally spaced,staggered centerrows
(Optional) Min. 1.5-inch ACFoam II,
FlintBoard ISO,ENRGY 3 or Multi-
Max FA3
HA
Min. 0.75-inch
FescoBoard
(homogeneous) or min.0.5-inch Structodek
High Density Fiberboard
HABP-AA or
SBS-AA
(Optional)BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
G-18.
Existing sound
gypsum or
gypsum plank
Glasbase; FlexiglasBase; Flintlastic
Base 20; All
Weather/EmpireBase; Yosemite
Trufast Twin
Loc-Nail
Assembled
Fastener
(min. 1.8")
7-inch o.c. at the 4-
inch lap and 7-incho.c. in two (2),equally spaced,staggered center
rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3 or Multi-
Max FA3
HA
Min. 0.75-inch
FescoBoard
(homogeneous) or min.0.5-inch Structodek
High Density Fiberboard
HABP-AA or
SBS-AA
(Optional)BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-60.0
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen RoofSystems; (610)651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19
Revision 20: 09/14/2017Appendix 1, Page 50 of 57
TRINITY ERD
TABLE6C: GYPSUM DECKS - REROOF(Tear-Off)
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)Base Insulation Layer(s)
Top Insulation Layer Roof Cover (Note 14)MDP (psf)
Type Fasteners Attach Base Ply Cap
G-19.
Existing soundgypsum or
gypsum plank
(Optional) One or morelayers, any combination,loose laid
Min. 0.5-inch Structodek
High Density FiberboardRoof Insulation
OMG Polymer GypTec with 3"GypTec Plate
1 per 2 ft*BP-AA or SBS-
AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
G-20.
Existing soundgypsum or
gypsum plank
(Optional) One or morelayers, any combination,loose laid
Min. 0.25-inch Dens Deck or
Dens Deck Prime
OMG Polymer GypTec with 3"GypTec Plate
1 per 1.78ft2BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
G-21.
Existing soundgypsum or
gypsum plank
(Optional) One or morelayers, any combination,loose laid
Min. 0.5-inch Structodek
High Density FiberboardRoof Insulation
Trufast Twin Loc-Nail Assembled
Fasteners (minimum 1-inchembedment into deck)
1 per 2 ft2BP-AA or SBS-
AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
G-22.
Existing soundgypsum or
gypsum plank
(Optional) One or morelayers, any combination,
loose laid
Min. 0.25-inch Dens Deck or
Dens Deck Prime or
SECUROCK Gypsum-FiberRoof Board
Trufast Twin Loc-Nail Assembled
Fasteners (minimum 1-inchembedment into deck)
1 per 2 ft2BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
TABLE 6D: GYPSUM DECKS-REROOF (Tear-Off)
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 14) MDP
(psf)Base Fasteners Attach Ply Cap
Self-Adhering Systems:
G-23.Existing sound gypsumor gypsum plank
Flintlastic SA NailBase
Trufast Twin Loc-Nail
Assembled Fastener
(min. 1.8")
9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2),equally spaced, staggered center rows
SBS-SA SBS-SA -60.0
Conventional Systems:
G-24.Existing sound gypsumor gypsum plank
AllWeather/ Empire Base;Yosemite
Trufast FM-75 or FM-90
Base Sheet Fastener
9-inch o.c. at the 4-inch lap and 18-inch o.c. in two (2),equally spaced, staggered center rows
BP-AA or'SBS-AA SBS-AA -45.0*
G-25.Existing sound gypsumor gypsum plank
Glasbase; Flexiglas Base; AllWeather / Empire Base; Yosemite
Simplex Turbo Tube-Lok9-inch o.c. at the 4-inch lap and 12-inch o.c. in two (2),equally spaced, staggered center rows
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-45.0*
G-26.Existing sound gypsumor gypsum plank
Glasbase; Flexiglas Base; FlintlasticBase 20; All Weather / EmpireBase; Yosemite
Trufast Twin Loc-Nail
Assembled Fastener
(min. 1.8")
9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2),equally spaced, staggered center rows
BP-AA or SBS-AASBS-AA, SBS-
TA or APP-TA-67.5
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6thEDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 51 of 57
TRINITY ERDTABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPEA-l: BONDEDINSULATION,BONDEDROOFCOVERSystem
No.Substrate (Notes 1 & 11)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Attach Type Attach Base Ply CapSelf-Adhering Systems:
R-lExisting fully bonded BURormodified bitumen roof cover
Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA; orSECUROCK Gypsum-Fiber RoofBoard.
HA None N/A SBS-SA (Optional) SBS-SA SBS-SA -105.0
R-2Existing fully bonded BURormodified bitumen roof cover
Min. 1.5-inch ACFoam II, FlintBoardISO, ENRGY3, H-Shield or Multi-MaxFA3
HA
Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA; orSECUROCKGypsum-Fiber RoofBoard.
HA SBS-SA (Optional) SBS-SA SBS-SA -105.0
R-3Existing fully bonded, smoothsurface BUR or modified bitumen
Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA or
SECUROCK Gypsum-Fiber RoofBoard
A-PD, 6-
inch o.c.None N/A SBS-SA (Optional) SBS-SA SBS-SA -105.0
R-4Existing fully bonded, mineralsurface modified bitumen
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
A-PD, 6-
inch o.c.None N/A SBS-SA (Optional) SBS-SA SBS-SA -172.5
R-5Existing fully bonded, mineralsurface modified bitumen
Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA
A-PD, 6-
inch o.c.None N/A SBS-SA (Optional) SBS-SA SBS-SA -180.0
R-6Existing fully bonded, smoothsurface BUR or modified bitumen
Min. 1.5-inch ACFoam II, FlintBoard,ENRGY 3 or Multi-Max FA3
A-PD, 6-
inch o.c.
Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA or
SECUROCK Gypsum-Fiber RoofBoard
A-PD, 6-
inch o.c.SBS-SA (Optional) SBS-SA SBS-SA -52.5
R-7Existing fully bonded, mineralsurface BUR or modified bitumen
Min. 1.5-inch ACFoam II,FlintBoard,ENRGY 3 or Multi-Max FA3
A-PD, 6-
inch o.c.
Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA or
SECUROCK Gypsum-Fiber RoofBoard
A-PD, 6-
inch o.c.SBS-SA (Optional) SBS-SA SBS-SA -172.5
R-8Existing fully bonded BURormodified bitumen roof cover
Min. 1.5-inch ACFoam II, FlintBoard,ENRGY 3 or H-Shield
M-OSFA
Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA or
SECUROCK Gypsum-Fiber RoofBoard
M-OSFA SBS-SA (Optional) SBS-SA SBS-SA -157.5
R-9
Existing fully bonded, smooth- orgranule-surface BUR or modifiedbitumen
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
M-PGl None N/A SBS-SA (Optional) SBS-SA SBS-SA -172.5
R-10
Existing fully bonded, smooth- orgranule-surface BUR or modifiedbitumen
Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA
M-PGl None N/A SBS-SA (Optional) SBS-SA SBS-SA -180.0
R-llExisting fully bonded BURormodified bitumen roof cover
Min. l.S-inch ACFoam II,FlintBoard,ENRGY 3 or H-Shield
M-PGlMin. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
M-PGl SBS-SA (Optional) SBS-SA SBS-SA -172.5
ExteriorResearch and Design,LLC. d/b/a Trinity| ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610)6S1-S847
Evaluation Report 3520.O3.O4-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 52 of 57
System
No.
R-12
R-13
R-14
R-15
R-16
R-17
R-18
Substrate (Notes 1 8111)
Existing fully bonded BURormodified bitumen roof cover
Existing fully bonded, smooth- orgranule-surface BUR or modifiedbitumen
Existing fully bonded BURormodified bitumen roof cover
Existing fully bonded, smooth- orgranule-surface BURor modifiedbitumen
Existing fully bonded, smooth- orgranule-surface BUR or modifiedbitumen
Existing fully bonded BUR ormodified bitumen roof cover
Existing fully bonded BUR ormodified bitumen roof cover
Hybrid Systems:
R-19
R-20
R-21
R-22
R-23
Existing fully bonded BURor
modified bitumen roof cover
Existing fully bonded, smoothsurface BUR or modified bitumen
Existing fully bonded, mineralsurface modified bitumen
Existing fully bonded, smooth- orgranule-surface BUR or modifiedbitumen
Existing fully bonded, smooth- orgranule-surface BUR or modifiedbitumen
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer
Type
Min. 1.5-inch ACFoam II, FlintBoard,
ENRGY 3 or Multi-Max FA
Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA or
SECUROCK Gypsum-Fiber RoofBoard
Min. 1.5-inch ACFoam II, FlintBoard
ISO or ENRGY 3
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA
Min. 1.0-inch ISO 95+ GL, H-Shield,
H-Shield CG, ENRGY3 or min. 1.3-
inch ACFoam III,Min. 1.5-inch Multi-Max FA3 or Ultra-Max
Min. 1.0-inch ISO 95+ GL, H-Shield,
H-Shield CG, ENRGY 3 or min. 1.3-
inch ACFoam III, Min. l.S-inch Multi-
Max FA3 or Ultra-Max
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
Attach
M-PGl
OB500
OB500
CR-20
CR-20
CR-20
CR-20
HA
A-PD, 6-
inch o.c.
A-PD, 6-
inch o.c.
M-PGl
OB500
Top Insulation Layer
Type
Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA
None
Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA or
SECUROCK Gypsum-Fiber Roof
Board
None
None
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
Min. 0.25-inch Dens Deck primed
with FlintPrime or FlintPrime SA
None
None
None
None
None
Attach
M-PGl
N/A
OB500
N/A
N/A
CR-20
CR-20
N/A
N/A
N/A
N/A
N/A
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6 EDITION (2017) FBCNON-HVHZ EVALUATIONCertainTeed Flintlastic" Modified Bitumen Roof Systems; (610) 651-5847
Base
SBS-SA
SBS-SA
SBS-SA
SBS-SA
SBS-SA
SBS-SA
SBS-SA
SBS-SA-H
SBS-SA-H
SBS-SA-H
SBS-SA-H
SBS-SA-H
TRINITY ERD
Roof Cover (Note 14)
Ply
(Optional) SBS-SA
(Optional) SBS-SA
(Optional) SBS-SA
(Optional) SBS-SA
(Optional) SBS-SA
(Optional) SBS-SA
(Optional) SBS-SA
(Optional) SBS-AA,
SBS-TA, APP-TA
(Optional) SBS-AA,SBS-TA, APP-TA
(Optional) SBS-AA,
SBS-TA, APP-TA
(Optional) SBS-AA,
SBS-TA, APP-TA
(Optional) SBS-AA,
SBS-TA, APP-TA
Cap
SBS-SA
SBS-SA
SBS-SA
SBS-SA
SBS-SA
SBS-SA
SBS-SA
SBS-AA, SBS-
TA, APP-TA
SBS-AA, SBS-
TA, APP-TA
SBS-AA, SBS-
TA, APP-TA
SBS-AA, SBS-
TA, APP-TA
SBS-AA, SBS-
TA, APP-TA
MDP
(psf)
-180.0
-120.0
-120.0
-172.5
-192.5
-172.5
-192.5
-105.0
-105.0
-180.0
-180.0
-120.0
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 53 of 57
TRINITY ERDTABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER
System
No.Substrate (Notes 1 & 11)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Attach Type Attach Base Ply Cap
R-24
Existing fully bonded, smooth- orgranule-surface BURor modifiedbitumen
Min. 0.25-inch SECUROCKGypsum-
Fiber Roof BoardCR-20 None N/A SBS-SA-H
(Optional) SBS-AA,SBS-TA, APP-TA
SBS-AA, SBS-
TA, APP-TA-195.0
Conventional Systems:
R-25Existing fully bonded BURormodified bitumen roof cover
0.5-inch Structodek High DensityFiberboard or min. 0.75-inch Fesco
Board (homogeneous)HA None N/A
BP-AA, SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-105.0
R-26Existing fully bonded BURormodified bitumen roof cover
0.25-inch Dens Deck, Dens Deck
Prime or SECUROCKGypsum-Fiber
Roof Board
HA None N/A
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-105.0
R-27Existing fully bonded BURormodified bitumen roof cover
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY3, H-Shield or Multi-Max
FA3
HA
Min. 0.5-inch Structodek HighDensity Fiberboard, Min. 0.75-inchFescoBoard (homogeneous) or Min.0.5-inch DuraBoard (homogeneous)
HABP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-105.0
R-28Existing fully bonded BURormodified bitumen roof cover
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY3, H-Shield or Multi-Max
FA3
HA
Min. 0.25-inch SECUROCKGypsum-Fiber Roof Board, Dens Deck, Dens
Deck Prime
HA
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-105.0
R-29Existing fully bonded, smoothsurface BUR or modified bitumen
Min. 0.5-inch Structodek HighDensity Fiberboard
A-PD, 6-
inch o.c.None N/A
BP-AA, SBS-
AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-105.0
R-30Existing fully bonded, mineralsurface modified bitumen
Min. 0.5-inch Structodek High
Density FiberboardA-PD, 6-
inch o.c.None N/A
BP-AA, SBS-
AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-180.0
R-31Existing fully bonded, smoothsurface BUR or modified bitumen
Min. 0.25-inch Dens Deck, Dens
Deck Prime or SECUROCKGypsum-
Fiber Roof Board
A-PD, 6-
inch o.c.None N/A
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-105.0
R-32Existing fully bonded, mineralsurface modified bitumen
Min. 0.25-inch Dens Deck, Dens
Deck Prime or SECUROCK Gypsum-Fiber Roof Board
A-PD, 6-
inch o.c.None N/A
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-180.0
R-33Existing fully bonded, smoothsurface BUR or modified bitumen
Min. l.S-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield
A-PD, 6-
inch o.c.
Min. 0.5-inch Structodek High
Density FiberboardA-PD, 6-
inch o.c.
BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-52.5
R-34Existing fully bonded, smooth
surface BUR or modified bitumen
Min. 2-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield
A-PD, 6-
inch o.c.
Min. 0.25-inch SECUROCKGypsum-
Fiber Roof Board or Dens Deck
A-PD, 6-
inch o.c.
BP-AA or
SBS-AA,
SBS-TA or
APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-52.5
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666thEDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic" Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19
Revision 20: 09/14/2017Appendix 1, Page 54 of 57
System
No.
R-35
R-36
R-37
R-38
R-39
R-40
R-41
R-42
R-43
R-44
R-45
Substrate (Notes 1 & 11)
Existing fully bonded, mineral
surface BUR or modified bitumen
Existing fully bonded, mineral
surface BUR or modified bitumen
Existing fully bonded BUR or
modified bitumen roof cover
Existing fully bonded BURormodified bitumen roof cover
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
Existing fully bonded, smooth- orgranule-surface BUR or modifiedbitumen
Existing fully bonded BUR or
modified bitumen roof cover
Existing fully bonded BUR or
modified bitumen roof cover
Existing fully bonded, smooth- or
granule-surface BURor modifiedbitumen
Existing fully bonded, smooth- or
granule-surface BURor modifiedbitumen
Existing fully bonded BUR or
modified bitumen roof cover
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer
Type
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield
Min. 2-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield
Min. 0.5-inch Structodek High
Density Fiberboard
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof
Board
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY3 or H-Shield
Min. 0.5-inch Structodek High
Density Fiberboard
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 or H-Shield
Attach
A-PD, 6-
inch o.c.
A-PD, 6-
inch o.c.
M-OSFA
M-OSFA
M-PGl
M-PGl
M-PGl
M-PGl
OB500
OB500
OB500
Top Insulation Layer
Type
Min. 0.5-inch Structodek High
Density Fiberboard
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or Dens Deck
Min. 0.5-inch Structodek High
Density Fiberboard
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board or Dens Deck
None
None
Min. 0.5-inch Structodek High
Density Fiberboard
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board or Dens Deck
None
None
Min. 0.5-inch Structodek High
Density Fiberboard
Attach
A-PD, 6-
inch o.c.
A-PD, 6-
inch o.c.
M-OSFA
M-OSFA
N/A
N/A
M-PGl
M-PGl
N/A
N/A
OB500
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Base
BP-AA or
SBS-AA
BP-AA or
SBS-AA,
SBS-TA or
APP-TA
BP-AA or
SBS-AA
BP-AA or
SBS-AA,
SBS-TA or
APP-TA
BP-AA, SBS-
AA
BP-AA, SBS-
AA, SBS-TA
or APP-TA
BP-AA or
SBS-AA
BP-AA or
SBS-AA,
SBS-TA or
APP-TA
BP-AA, SBS-
AA
BP-AA, SBS-
AA, SBS-TA
or APP-TA
BP-AA or
SBS-AA
TRINITY erd
Roof Cover(Note 14)
Ply
(Optional) BP-AA,
S3S-AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
Cap
SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-
TA or APP-TA
MDP
(psf)
-172.5
-172.5
-127.5
-157.5
-180.0
-180.0
-180.0
-180.0
-120.0
-120.0
-120.0
Evaluation Report 3520.03.04-R20 for FL2533-R19
Revision 20: 09/14/2017Appendix 1, Page 55 of 57
TRINITY ERDTABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER
System
No.Substrate (Notes 1 & 11)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Attach Type Attach Base Ply Cap
R-46Existing fully bonded BURormodified bitumen roof cover
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY3 or H-ShieldOB500
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, Dens Deck or Dens
Deck Prime
OB500
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-120.0
R-47
Existing fully bonded, smooth- orgranule-surface BURor modifiedbitumen
Min. 0.5-inch Structodek HighDensity Fiberboard
CR-20 None N/ABP-AA, SBS-
AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-195.0
R-48
Existing fully bonded, smooth- orgranule-surface BURor modifiedbitumen
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
CR-20 None N/ABP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-195.0
R-49Existing fully bonded BURormodified bitumen roof cover
Min. 1.0-inch ISO 95+ GL, H-Shield,
H-Shield CG, ENRGY3 or min. 1.3-
inch ACFoam III, Min. 1.5-inch Multi-
Max FA3 or Ultra-Max
CR-20Min. 0.25-inch Dens Deck or Dens
Deck PrimeCR-20 SBS-TA (Optional) SBS-TA SBS-TA -180.0
R-50Existing fully bonded BUR ormodified bitumen roof cover
Min. 1.0-inch ISO 95+ GL, H-Shield,
H-Shield CG, ENRGY3 or min. 1.3-
inch ACFoam III, Min. 1.5-inch Multi-
Max FA3 or Ultra-Max
CR-20
Min. 0.5-inch Structodek HighDensity Fiberboard or DuraBoard(homogeneous) or min. 1.5-inchFescoBoard (laminated)
CR-20BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-180.0
R-51Existing fully bonded BURormodified bitumen roof cover
Min. 1.0-inch ISO 95+ GL, H-Shield,
H-Shield CG, ENRGY 3 or min. 1.3-
inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max
CR-20Min. 0.25-inch SECUROCKGypsum-
Fiber Roof BoardCR-20
BP-AA or
SBS-AA
(Optional) BP-AA,SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-225.0
R-52Existing fully bonded BURormodified bitumen roof cover
Min. 1.0-inch ISO 95+ GL, H-Shield,
H-Shield CG, ENRGY3 or min. 1.3-
inch ACFoam III, Min. l.S-inch Multi-
Max FA3 or Ultra-Max
CR-20Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
CR-20SBS-TA or
APP-TA
(Optional) SBS-TAor APP-TA
SBS-TA or
APP-TA-232.5
R-53Existing fully bonded BURormodified bitumen roof cover
Min. 1.0-inch ISO 95+ GL, H-Shield,
H-Shield CG, ENRGY3 or min. 1.3-
inch ACFoam III, Min. 1.5-inch Multi-
Max FA3 or Ultra-Max
CR-20 Min. 0.25-inch Dens Deck CR-20BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA-240.0
Cold-applied Systems:
R-54Existing fully bonded BURormodified bitumen roof cover
(Optional) Min. 0.5-inch ACFoam II,FlintBoard ISO, H-Shield, FlintBoard
ISOH
OB500
Min. 1.5-inch ACFoam III, FlintBoard
Iso Cold, H-Shield CG or FlintBoard
Iso ColdH
OB500 SBS-CAl None SBS-CAl -82.5
R-55Existing fully bonded BURormodified bitumen roof cover
(Optional) Min. 0.5-inch ACFoam II,FlintBoard ISO, H-Shield, FlintBoardISOH
CR-20
Min. l.S-inch ACFoam III, FlintBoard
Iso Cold, H-Shield CG or FlintBoard
Iso ColdH
CR-20 SBS-CAl None SBS-CAl -82.5
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2S33-R19Revision 20: 09/14/2017
Appendix 1, Page 56 of 57
TRINITY ERDTABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER
System
No.Substrate (Notes 1 & 11)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
(psf)Type Attach Type Attach Base Ply Cap
R-56
Existing fully bonded, smooth- or
granule-surface BURor modifiedbitumen
Min. 0.25-inch SECUROCKGypsum-
Fiber Roof Board
A-PD, 6-
inch o.c.None N/A SBS-CAl None SBS-CAl -105.0
R-57Existing fully bonded, smoothsurface BUR or modified bitumen
Min. 0.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH
A-PD, 6-
inch o.c.
Min. 0.25-inch SECUROCKGypsum-
Fiber Roof Board
A-PD, 6-
inch o.c.SBS-CAl None SBS-CAl -52.S
R-58Existing fully bonded, mineralsurface BUR or modified bitumen
Min. 0.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISO„
A-PD, 6-
inch o.c.
Min. 0.25-inch SECUROCKGypsum-
Fiber Roof Board
A-PD, 6-
inch o.c.SBS-CAl None SBS-CAl -105.0
R-59
Existing fully bonded, smooth- orgranule-surface BURor modifiedbitumen
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
M-PGl None N/A SBS-CAl None SBS-CAl -105.0
R-60Existing futly bonded, mineral
surface BUR or modified bitumen
Min. 0.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOH
M-OSFA,
M-PGl
Min. 0.25-inch SECUROCKGypsum-
Fiber Roof Board
M-OSFA,
M-PGlSBS-CAl None SBS-CAl -105.0
R-61
Existing fully bonded, smooth- orgranule-surface BURor modifiedbitumen
Min. 0.2S-inch SECUROCKGypsum-
Fiber Roof BoardOB500 None N/A SBS-CAl None SBS-CAl -105.0
R-62Existing fully bonded, mineralsurface BUR or modified bitumen
Min. 0.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOHOB500
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
OB500 SBS-CAl None SBS-CAl -105.0
R-63
Existing fully bonded, smooth- or
granule-surface BURor modifiedbitumen
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof BoardCR-20 None N/A SBS-CAl None SBS-CAl -105.0
R-64Existing fully bonded, mineralsurface BUR or modified bitumen
Min. 0.5-inch ACFoam II, FlintBoard
ISO, H-Shield, FlintBoard ISOHCR-20
Min. 0.25-inch SECUROCKGypsum-
Fiber Roof BoardCR-20 SBS-CAl None SBS-CAl -105.0
TABLE7B: RECOVERAPPLICATIONS- NEW CONSTRUCTION or REROOF(Tear-Off)
SYSTEM TYPE F:NON-INSULATED, BONDED ROOF COVER
System
No.
Substrate
(Notes 1 & 11)Primer
Roof Cover (Note 14)MDP (psf)
Base Ply Cap
R-65 Existing fully bonded BURover structural concrete deck (Optional) FlintPrime (ASTM D41) SBS-CAl None SBS-CAl -187.5
Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503
Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION
CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847
Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017
Appendix 1, Page 57 of 57