Page 1: 30:1 Infrared Thermometer Electronic Voltage Testers

Innovative Features...Superior Value

See our complete line of Test and Measurement products at

www.kleintools.com

IR 300030:1 Infrared ThermometerDual Laser Targeting

30:1 Infrared ThermometerIR 3000

• Distance to Spot 30:1• -76˚ ~ 1400˚F (-60 ~ 760˚C)• K-Type thermocouple Input• Dual Lasers allow you

to see the actual target diameter

FEATURES IR3000

Temperature Range-76~1400°F-60~760°C

K-Type Thermocouple Range-83.2~2552°F-64~1400°C

Dual Laser Targeting â—Ź

Emissivity 0.10~1.00

High/Low Alarms â—Ź

Backlit Display â—Ź

Worklight â—Ź

°F/°C Button ●

Max / Min / Average / Differential MAX/MIN â—Ź

Auto Shut Off / Seconds Apo 60sec

Diameter at Spot

Distance to Object

0.5”1”

2”4”

15”30”60”120”

Electronic Voltage TestersET 100 & ET 200

Non-Contact Voltage TestersNCVT-1 & NCVT-2

Features:• Measures AC and DC voltage at nine common levels up to 600V• Bright LED’s indicate voltage reading without batteries installed• Low impedance input reduces possibility of ghost voltages• Molded lead holders are perfect for easy measurments

of tamper proof outlets

Additional features for the ET200• Bright worklight to illuminate your work space• Audible continuity at less than 270kHz

Features:• Non-Contact voltage detection of voltage in cables, cords,

circuit breakers, light fixtures, switches, outlets and wires• When voltage is detected, a high intensity, bright red

LED illuminates and a warning tone sounds

Additional features for the NCVT-2• Automatically detects both low and standard voltages

CAT

IVCAT

CAT

IVCAT

V

V

ET200

ET100

© 2012 Klein Tools, Inc. Lincolnshire, IL. 60069-1418 Printed in U.S.A. 96125

600V

600VET100

NCVT-1

NCVT-2

ET200

Thermocouple Protective Boot Batteries Carrying Pouch

Includes:

Dual Range

HVA

C TE

ST

ING

EQ

UIP

ME

NT

Testing Equipment

HVAC

WARNING: Read, understand, and follow all instructions, cautions and warnings attached to and/or packed with all Test and Measurement devices before each use.

Apo MIN/MAX

Apo MIN/MAX

P R O F E S S I O N A L S E R I E S H V A C T E S T & M E A S U R E M E N T

Page 2: 30:1 Infrared Thermometer Electronic Voltage Testers

Electrician’s / HVAC Multimeter

600A ACClamp w/ Temperature

600A AC / DCTRMS Clamp w/ Temperature

Electrician’s / HVAC TRMS Multimeter

MEASUREMENT CL1300 CL2300

AC Current 600A 600A

DC Current no 600A

AC Voltage 750V 750V

DC Voltage 1000V 1000V

LCD Display 6000 6000

Audible Continuity â—Ź â—Ź

Resistance Range 60MΩ 60MΩ

HOLD Data Hold â—Ź â—Ź

AUTO Auto Ranging â—Ź â—Ź

Low Battery â—Ź â—Ź

Apo Auto Power-Off â—Ź â—Ź

Back Light â—Ź â—Ź

Work/Clamp Light â—Ź â—Ź

Frequency/Duty Cycle â—Ź â—Ź

Frequency Limit 499.9kHz 499.9kHz

Capacitance 6000ÎĽF 6000ÎĽF

Diode Test â—Ź â—Ź

Non Contact Voltage â—Ź â—Ź

MAX/MIN Min/Max â—Ź â—Ź

Magnetic Mount â—Ź â—Ź

Lead Storage â—Ź â—Ź

ÎĽ Micro Amps 0.1ÎĽA 0.1ÎĽA

Bar Graph â—Ź â—Ź

Temperature â—Ź â—Ź

TRMS True RMS no â—Ź

Safety Rating CAT IV 600V CAT IV 600V

Digital Clamps w/ Temperature CL 1300, CL 2300

Digital Multimeters w/ Temperature MM 1300, MM 2300

Digital Temperature LoggersDTL 302, DTL 304

DTL 304MM 2300CL 2300

DTL 302MM 1300CL 1300Dual Input Temperature Logger

Quad Input Temperature Logger

• IP67: Water Proof/Dust Resistant• Differential T1-T2• Data Logging• 9,999 Memory Positions• MIN, MAX, AVG & Hold

• IP67: Water Proof/Dust Resistant• Differential T1-T2 & T3-T4• Data Logging• 9,999 Memory Positions• MIN, MAX, AVG & Hold

J-type -346° to 2192°F K-type -328° to 2498°FT-type -418° to 752°FE-type -238° to 1832°F

• True RMS • Backlit Display & Worklight• Magnetic Mount & Lead Storage• Non-Contact Voltage Tester• Analog Bar Graph• Temperature

• Backlit Display & Worklight• Magnetic Mount & Lead Storage• Non-Contact Voltage Tester• Analog Bar Graph• Temperature

• True RMS Measurements • Backlit Display• Analog Bar Graph

• Backlit Display• Analog Bar Graph MEASUREMENT MM1300 MM2300

AC Voltage 1000V 1000V

DC Voltage 1000V 1000V

AC Current 10A 10A

DC Current 10A 10A

LCD Display 6000 6000

Audible Continuity â—Ź â—Ź

Resistance Range 60MΩ 60MΩ

AUTO/HOLD Auto Hold â—Ź â—Ź

Diode Test â—Ź â—Ź

Low Battery â—Ź â—Ź

Apo Auto Power-Off â—Ź â—Ź

Back Light â—Ź â—Ź

ÎĽ Micro Amps 0.1ÎĽA 0.1ÎĽA

Capacitance 6000ÎĽF 6000ÎĽF

RANGE Range Hold â—Ź â—Ź

AUTO Auto Ranging â—Ź â—Ź

Frequency Limit 499.9kHz 499.9kHz

MAX/MIN Min/Max â—Ź â—Ź

Bar Graph â—Ź â—Ź

Temperature -58 ~ 1832°F -58 ~ 1832°F

Frequency / Duty Cycle â—Ź â—Ź

Δ Relative Reading ● ●

Low Impedance no â—Ź

TRMS True RMS no â—Ź

Safety Rating CAT IV 600V CAT IV 600V

FEATURESJ,K,T&EThermocoupleTypes

DifferentialTemperature

DataLogging

9,999MemoryPositions

USBInterface(Software included)

ThermocoupleTemperatureOffset

MIN/MAX/Average/Hold

BacklitDisplay

ProbeStorage

Bootw/Stand&MagneticStrapMount

ComplianceRatingIP67

Test Leads Test LeadsThermocouple ThermocoupleBatteries BatteriesCarrying Pouch

Includes: Includes:

Carrying Pouch

HVA

C TE

ST

ING

EQ

UIP

ME

NT

HVA

C TE

ST

ING

EQ

UIP

ME

NT

TRMS

HOLD AUTO

MIN/MAX

TRMS

HOLD

Apo RANGE

AUTO

CAT

IVCAT 600V

1000V

600V

CAT

IVCAT

1000VThermocouples Magnetic

Hanger StrapUSB Power Adapter

Includes:

Batteries

Apo AVG

MIN/MAXIP67

HOLD

Page 3: 30:1 Infrared Thermometer Electronic Voltage Testers

Electrician’s / HVAC Multimeter

600A ACClamp w/ Temperature

600A AC / DCTRMS Clamp w/ Temperature

Electrician’s / HVAC TRMS Multimeter

MEASUREMENT CL1300 CL2300

AC Current 600A 600A

DC Current no 600A

AC Voltage 750V 750V

DC Voltage 1000V 1000V

LCD Display 6000 6000

Audible Continuity â—Ź â—Ź

Resistance Range 60MΩ 60MΩ

HOLD Data Hold â—Ź â—Ź

AUTO Auto Ranging â—Ź â—Ź

Low Battery â—Ź â—Ź

Apo Auto Power-Off â—Ź â—Ź

Back Light â—Ź â—Ź

Work/Clamp Light â—Ź â—Ź

Frequency/Duty Cycle â—Ź â—Ź

Frequency Limit 499.9kHz 499.9kHz

Capacitance 6000ÎĽF 6000ÎĽF

Diode Test â—Ź â—Ź

Non Contact Voltage â—Ź â—Ź

MAX/MIN Min/Max â—Ź â—Ź

Magnetic Mount â—Ź â—Ź

Lead Storage â—Ź â—Ź

ÎĽ Micro Amps 0.1ÎĽA 0.1ÎĽA

Bar Graph â—Ź â—Ź

Temperature â—Ź â—Ź

TRMS True RMS no â—Ź

Safety Rating CAT IV 600V CAT IV 600V

Digital Clamps w/ Temperature CL 1300, CL 2300

Digital Multimeters w/ Temperature MM 1300, MM 2300

Digital Temperature LoggersDTL 302, DTL 304

DTL 304MM 2300CL 2300

DTL 302MM 1300CL 1300Dual Input Temperature Logger

Quad Input Temperature Logger

• IP67: Water Proof/Dust Resistant• Differential T1-T2• Data Logging• 9,999 Memory Positions• MIN, MAX, AVG & Hold

• IP67: Water Proof/Dust Resistant• Differential T1-T2 & T3-T4• Data Logging• 9,999 Memory Positions• MIN, MAX, AVG & Hold

J-type -346° to 2192°F K-type -328° to 2498°FT-type -418° to 752°FE-type -238° to 1832°F

• True RMS • Backlit Display & Worklight• Magnetic Mount & Lead Storage• Non-Contact Voltage Tester• Analog Bar Graph• Temperature

• Backlit Display & Worklight• Magnetic Mount & Lead Storage• Non-Contact Voltage Tester• Analog Bar Graph• Temperature

• True RMS Measurements • Backlit Display• Analog Bar Graph

• Backlit Display• Analog Bar Graph MEASUREMENT MM1300 MM2300

AC Voltage 1000V 1000V

DC Voltage 1000V 1000V

AC Current 10A 10A

DC Current 10A 10A

LCD Display 6000 6000

Audible Continuity â—Ź â—Ź

Resistance Range 60MΩ 60MΩ

AUTO/HOLD Auto Hold â—Ź â—Ź

Diode Test â—Ź â—Ź

Low Battery â—Ź â—Ź

Apo Auto Power-Off â—Ź â—Ź

Back Light â—Ź â—Ź

ÎĽ Micro Amps 0.1ÎĽA 0.1ÎĽA

Capacitance 6000ÎĽF 6000ÎĽF

RANGE Range Hold â—Ź â—Ź

AUTO Auto Ranging â—Ź â—Ź

Frequency Limit 499.9kHz 499.9kHz

MAX/MIN Min/Max â—Ź â—Ź

Bar Graph â—Ź â—Ź

Temperature -58 ~ 1832°F -58 ~ 1832°F

Frequency / Duty Cycle â—Ź â—Ź

Δ Relative Reading ● ●

Low Impedance no â—Ź

TRMS True RMS no â—Ź

Safety Rating CAT IV 600V CAT IV 600V

FEATURESJ,K,T&EThermocoupleTypes

DifferentialTemperature

DataLogging

9,999MemoryPositions

USBInterface(Software included)

ThermocoupleTemperatureOffset

MIN/MAX/Average/Hold

BacklitDisplay

ProbeStorage

Bootw/Stand&MagneticStrapMount

ComplianceRatingIP67

Test Leads Test LeadsThermocouple ThermocoupleBatteries BatteriesCarrying Pouch

Includes: Includes:

Carrying Pouch

HVA

C TE

ST

ING

EQ

UIP

ME

NT

HVA

C TE

ST

ING

EQ

UIP

ME

NT

TRMS

HOLD AUTO

MIN/MAX

TRMS

HOLD

Apo RANGE

AUTO

CAT

IVCAT 600V

1000V

600V

CAT

IVCAT

1000VThermocouples Magnetic

Hanger StrapUSB Power Adapter

Includes:

Batteries

Apo AVG

MIN/MAXIP67

HOLD

Page 4: 30:1 Infrared Thermometer Electronic Voltage Testers

Electrician’s / HVAC Multimeter

600A ACClamp w/ Temperature

600A AC / DCTRMS Clamp w/ Temperature

Electrician’s / HVAC TRMS Multimeter

MEASUREMENT CL1300 CL2300

AC Current 600A 600A

DC Current no 600A

AC Voltage 750V 750V

DC Voltage 1000V 1000V

LCD Display 6000 6000

Audible Continuity â—Ź â—Ź

Resistance Range 60MΩ 60MΩ

HOLD Data Hold â—Ź â—Ź

AUTO Auto Ranging â—Ź â—Ź

Low Battery â—Ź â—Ź

Apo Auto Power-Off â—Ź â—Ź

Back Light â—Ź â—Ź

Work/Clamp Light â—Ź â—Ź

Frequency/Duty Cycle â—Ź â—Ź

Frequency Limit 499.9kHz 499.9kHz

Capacitance 6000ÎĽF 6000ÎĽF

Diode Test â—Ź â—Ź

Non Contact Voltage â—Ź â—Ź

MAX/MIN Min/Max â—Ź â—Ź

Magnetic Mount â—Ź â—Ź

Lead Storage â—Ź â—Ź

ÎĽ Micro Amps 0.1ÎĽA 0.1ÎĽA

Bar Graph â—Ź â—Ź

Temperature â—Ź â—Ź

TRMS True RMS no â—Ź

Safety Rating CAT IV 600V CAT IV 600V

Digital Clamps w/ Temperature CL 1300, CL 2300

Digital Multimeters w/ Temperature MM 1300, MM 2300

Digital Temperature LoggersDTL 302, DTL 304

DTL 304MM 2300CL 2300

DTL 302MM 1300CL 1300Dual Input Temperature Logger

Quad Input Temperature Logger

• IP67: Water Proof/Dust Resistant• Differential T1-T2• Data Logging• 9,999 Memory Positions• MIN, MAX, AVG & Hold

• IP67: Water Proof/Dust Resistant• Differential T1-T2 & T3-T4• Data Logging• 9,999 Memory Positions• MIN, MAX, AVG & Hold

J-type -346° to 2192°F K-type -328° to 2498°FT-type -418° to 752°FE-type -238° to 1832°F

• True RMS • Backlit Display & Worklight• Magnetic Mount & Lead Storage• Non-Contact Voltage Tester• Analog Bar Graph• Temperature

• Backlit Display & Worklight• Magnetic Mount & Lead Storage• Non-Contact Voltage Tester• Analog Bar Graph• Temperature

• True RMS Measurements • Backlit Display• Analog Bar Graph

• Backlit Display• Analog Bar Graph MEASUREMENT MM1300 MM2300

AC Voltage 1000V 1000V

DC Voltage 1000V 1000V

AC Current 10A 10A

DC Current 10A 10A

LCD Display 6000 6000

Audible Continuity â—Ź â—Ź

Resistance Range 60MΩ 60MΩ

AUTO/HOLD Auto Hold â—Ź â—Ź

Diode Test â—Ź â—Ź

Low Battery â—Ź â—Ź

Apo Auto Power-Off â—Ź â—Ź

Back Light â—Ź â—Ź

ÎĽ Micro Amps 0.1ÎĽA 0.1ÎĽA

Capacitance 6000ÎĽF 6000ÎĽF

RANGE Range Hold â—Ź â—Ź

AUTO Auto Ranging â—Ź â—Ź

Frequency Limit 499.9kHz 499.9kHz

MAX/MIN Min/Max â—Ź â—Ź

Bar Graph â—Ź â—Ź

Temperature -58 ~ 1832°F -58 ~ 1832°F

Frequency / Duty Cycle â—Ź â—Ź

Δ Relative Reading ● ●

Low Impedance no â—Ź

TRMS True RMS no â—Ź

Safety Rating CAT IV 600V CAT IV 600V

FEATURESJ,K,T&EThermocoupleTypes

DifferentialTemperature

DataLogging

9,999MemoryPositions

USBInterface(Software included)

ThermocoupleTemperatureOffset

MIN/MAX/Average/Hold

BacklitDisplay

ProbeStorage

Bootw/Stand&MagneticStrapMount

ComplianceRatingIP67

Test Leads Test LeadsThermocouple ThermocoupleBatteries BatteriesCarrying Pouch

Includes: Includes:

Carrying Pouch

HVA

C TE

ST

ING

EQ

UIP

ME

NT

HVA

C TE

ST

ING

EQ

UIP

ME

NT

TRMS

HOLD AUTO

MIN/MAX

TRMS

HOLD

Apo RANGE

AUTO

CAT

IVCAT 600V

1000V

600V

CAT

IVCAT

1000VThermocouples Magnetic

Hanger StrapUSB Power Adapter

Includes:

Batteries

Apo AVG

MIN/MAXIP67

HOLD

Page 5: 30:1 Infrared Thermometer Electronic Voltage Testers

Innovative Features...Superior Value

See our complete line of Test and Measurement products at

www.kleintools.com

IR 300030:1 Infrared ThermometerDual Laser Targeting

30:1 Infrared ThermometerIR 3000

• Distance to Spot 30:1• -76˚ ~ 1400˚F (-60 ~ 760˚C)• K-Type thermocouple Input• Dual Lasers allow you

to see the actual target diameter

FEATURES IR3000

Temperature Range-76~1400°F-60~760°C

K-Type Thermocouple Range-83.2~2552°F-64~1400°C

Dual Laser Targeting â—Ź

Emissivity 0.10~1.00

High/Low Alarms â—Ź

Backlit Display â—Ź

Worklight â—Ź

°F/°C Button ●

Max / Min / Average / Differential MAX/MIN â—Ź

Auto Shut Off / Seconds Apo 60sec

Diameter at Spot

Distance to Object

0.5”1”

2”4”

15”30”60”120”

Electronic Voltage TestersET 100 & ET 200

Non-Contact Voltage TestersNCVT-1 & NCVT-2

Features:• Measures AC and DC voltage at nine common levels up to 600V• Bright LED’s indicate voltage reading without batteries installed• Low impedance input reduces possibility of ghost voltages• Molded lead holders are perfect for easy measurments

of tamper proof outlets

Additional features for the ET200• Bright worklight to illuminate your work space• Audible continuity at less than 270kHz

Features:• Non-Contact voltage detection of voltage in cables, cords,

circuit breakers, light fixtures, switches, outlets and wires• When voltage is detected, a high intensity, bright red

LED illuminates and a warning tone sounds

Additional features for the NCVT-2• Automatically detects both low and standard voltages

CAT

IVCAT

CAT

IVCAT

V

V

ET200

ET100

© 2012 Klein Tools, Inc. Lincolnshire, IL. 60069-1418 Printed in U.S.A. 96125

600V

600VET100

NCVT-1

NCVT-2

ET200

Thermocouple Protective Boot Batteries Carrying Pouch

Includes:

Dual Range

HVA

C TE

ST

ING

EQ

UIP

ME

NT

Testing Equipment

HVAC

WARNING: Read, understand, and follow all instructions, cautions and warnings attached to and/or packed with all Test and Measurement devices before each use.

Apo MIN/MAX

Apo MIN/MAX

P R O F E S S I O N A L S E R I E S H V A C T E S T & M E A S U R E M E N T

Page 6: 30:1 Infrared Thermometer Electronic Voltage Testers

Innovative Features...Superior Value

See our complete line of Test and Measurement products at

www.kleintools.com

IR 300030:1 Infrared ThermometerDual Laser Targeting

30:1 Infrared ThermometerIR 3000

• Distance to Spot 30:1• -76˚ ~ 1400˚F (-60 ~ 760˚C)• K-Type thermocouple Input• Dual Lasers allow you

to see the actual target diameter

FEATURES IR3000

Temperature Range-76~1400°F-60~760°C

K-Type Thermocouple Range-83.2~2552°F-64~1400°C

Dual Laser Targeting â—Ź

Emissivity 0.10~1.00

High/Low Alarms â—Ź

Backlit Display â—Ź

Worklight â—Ź

°F/°C Button ●

Max / Min / Average / Differential MAX/MIN â—Ź

Auto Shut Off / Seconds Apo 60sec

Diameter at Spot

Distance to Object

0.5”1”

2”4”

15”30”60”120”

Electronic Voltage TestersET 100 & ET 200

Non-Contact Voltage TestersNCVT-1 & NCVT-2

Features:• Measures AC and DC voltage at nine common levels up to 600V• Bright LED’s indicate voltage reading without batteries installed• Low impedance input reduces possibility of ghost voltages• Molded lead holders are perfect for easy measurments

of tamper proof outlets

Additional features for the ET200• Bright worklight to illuminate your work space• Audible continuity at less than 270kHz

Features:• Non-Contact voltage detection of voltage in cables, cords,

circuit breakers, light fixtures, switches, outlets and wires• When voltage is detected, a high intensity, bright red

LED illuminates and a warning tone sounds

Additional features for the NCVT-2• Automatically detects both low and standard voltages

CAT

IVCAT

CAT

IVCAT

V

V

ET200

ET100

© 2012 Klein Tools, Inc. Lincolnshire, IL. 60069-1418 Printed in U.S.A. 96125

600V

600VET100

NCVT-1

NCVT-2

ET200

Thermocouple Protective Boot Batteries Carrying Pouch

Includes:

Dual RangeH

VAC T

ES

TIN

G E

QU

IPM

EN

T

Testing Equipment

HVAC

WARNING: Read, understand, and follow all instructions, cautions and warnings attached to and/or packed with all Test and Measurement devices before each use.

Apo MIN/MAX

Apo MIN/MAX

P R O F E S S I O N A L S E R I E S H V A C T E S T & M E A S U R E M E N T