Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
Innovative Features...Superior Value
See our complete line of Test and Measurement products at
www.kleintools.com
IR 300030:1 Infrared ThermometerDual Laser Targeting
30:1 Infrared ThermometerIR 3000
• Distance to Spot 30:1• -76˚ ~ 1400˚F (-60 ~ 760˚C)• K-Type thermocouple Input• Dual Lasers allow you
to see the actual target diameter
FEATURES IR3000
Temperature Range-76~1400°F-60~760°C
K-Type Thermocouple Range-83.2~2552°F-64~1400°C
Dual Laser Targeting â—Ź
Emissivity 0.10~1.00
High/Low Alarms â—Ź
Backlit Display â—Ź
Worklight â—Ź
°F/°C Button ●
Max / Min / Average / Differential MAX/MIN â—Ź
Auto Shut Off / Seconds Apo 60sec
Diameter at Spot
Distance to Object
0.5”1”
2”4”
15”30”60”120”
Electronic Voltage TestersET 100 & ET 200
Non-Contact Voltage TestersNCVT-1 & NCVT-2
Features:• Measures AC and DC voltage at nine common levels up to 600V• Bright LED’s indicate voltage reading without batteries installed• Low impedance input reduces possibility of ghost voltages• Molded lead holders are perfect for easy measurments
of tamper proof outlets
Additional features for the ET200• Bright worklight to illuminate your work space• Audible continuity at less than 270kHz
Features:• Non-Contact voltage detection of voltage in cables, cords,
circuit breakers, light fixtures, switches, outlets and wires• When voltage is detected, a high intensity, bright red
LED illuminates and a warning tone sounds
Additional features for the NCVT-2• Automatically detects both low and standard voltages
CAT
IVCAT
CAT
IVCAT
V
V
ET200
ET100
© 2012 Klein Tools, Inc. Lincolnshire, IL. 60069-1418 Printed in U.S.A. 96125
600V
600VET100
NCVT-1
NCVT-2
ET200
Thermocouple Protective Boot Batteries Carrying Pouch
Includes:
Dual Range
HVA
C TE
ST
ING
EQ
UIP
ME
NT
Testing Equipment
HVAC
WARNING: Read, understand, and follow all instructions, cautions and warnings attached to and/or packed with all Test and Measurement devices before each use.
Apo MIN/MAX
Apo MIN/MAX
P R O F E S S I O N A L S E R I E S H V A C T E S T & M E A S U R E M E N T
Electrician’s / HVAC Multimeter
600A ACClamp w/ Temperature
600A AC / DCTRMS Clamp w/ Temperature
Electrician’s / HVAC TRMS Multimeter
MEASUREMENT CL1300 CL2300
AC Current 600A 600A
DC Current no 600A
AC Voltage 750V 750V
DC Voltage 1000V 1000V
LCD Display 6000 6000
Audible Continuity â—Ź â—Ź
Resistance Range 60MΩ 60MΩ
HOLD Data Hold â—Ź â—Ź
AUTO Auto Ranging â—Ź â—Ź
Low Battery â—Ź â—Ź
Apo Auto Power-Off â—Ź â—Ź
Back Light â—Ź â—Ź
Work/Clamp Light â—Ź â—Ź
Frequency/Duty Cycle â—Ź â—Ź
Frequency Limit 499.9kHz 499.9kHz
Capacitance 6000ÎĽF 6000ÎĽF
Diode Test â—Ź â—Ź
Non Contact Voltage â—Ź â—Ź
MAX/MIN Min/Max â—Ź â—Ź
Magnetic Mount â—Ź â—Ź
Lead Storage â—Ź â—Ź
ÎĽ Micro Amps 0.1ÎĽA 0.1ÎĽA
Bar Graph â—Ź â—Ź
Temperature â—Ź â—Ź
TRMS True RMS no â—Ź
Safety Rating CAT IV 600V CAT IV 600V
Digital Clamps w/ Temperature CL 1300, CL 2300
Digital Multimeters w/ Temperature MM 1300, MM 2300
Digital Temperature LoggersDTL 302, DTL 304
DTL 304MM 2300CL 2300
DTL 302MM 1300CL 1300Dual Input Temperature Logger
Quad Input Temperature Logger
• IP67: Water Proof/Dust Resistant• Differential T1-T2• Data Logging• 9,999 Memory Positions• MIN, MAX, AVG & Hold
• IP67: Water Proof/Dust Resistant• Differential T1-T2 & T3-T4• Data Logging• 9,999 Memory Positions• MIN, MAX, AVG & Hold
J-type -346° to 2192°F K-type -328° to 2498°FT-type -418° to 752°FE-type -238° to 1832°F
• True RMS • Backlit Display & Worklight• Magnetic Mount & Lead Storage• Non-Contact Voltage Tester• Analog Bar Graph• Temperature
• Backlit Display & Worklight• Magnetic Mount & Lead Storage• Non-Contact Voltage Tester• Analog Bar Graph• Temperature
• True RMS Measurements • Backlit Display• Analog Bar Graph
• Backlit Display• Analog Bar Graph MEASUREMENT MM1300 MM2300
AC Voltage 1000V 1000V
DC Voltage 1000V 1000V
AC Current 10A 10A
DC Current 10A 10A
LCD Display 6000 6000
Audible Continuity â—Ź â—Ź
Resistance Range 60MΩ 60MΩ
AUTO/HOLD Auto Hold â—Ź â—Ź
Diode Test â—Ź â—Ź
Low Battery â—Ź â—Ź
Apo Auto Power-Off â—Ź â—Ź
Back Light â—Ź â—Ź
ÎĽ Micro Amps 0.1ÎĽA 0.1ÎĽA
Capacitance 6000ÎĽF 6000ÎĽF
RANGE Range Hold â—Ź â—Ź
AUTO Auto Ranging â—Ź â—Ź
Frequency Limit 499.9kHz 499.9kHz
MAX/MIN Min/Max â—Ź â—Ź
Bar Graph â—Ź â—Ź
Temperature -58 ~ 1832°F -58 ~ 1832°F
Frequency / Duty Cycle â—Ź â—Ź
Δ Relative Reading ● ●
Low Impedance no â—Ź
TRMS True RMS no â—Ź
Safety Rating CAT IV 600V CAT IV 600V
FEATURESJ,K,T&EThermocoupleTypes
DifferentialTemperature
DataLogging
9,999MemoryPositions
USBInterface(Software included)
ThermocoupleTemperatureOffset
MIN/MAX/Average/Hold
BacklitDisplay
ProbeStorage
Bootw/Stand&MagneticStrapMount
ComplianceRatingIP67
Test Leads Test LeadsThermocouple ThermocoupleBatteries BatteriesCarrying Pouch
Includes: Includes:
Carrying Pouch
HVA
C TE
ST
ING
EQ
UIP
ME
NT
HVA
C TE
ST
ING
EQ
UIP
ME
NT
TRMS
HOLD AUTO
MIN/MAX
TRMS
HOLD
Apo RANGE
AUTO
CAT
IVCAT 600V
1000V
600V
CAT
IVCAT
1000VThermocouples Magnetic
Hanger StrapUSB Power Adapter
Includes:
Batteries
Apo AVG
MIN/MAXIP67
HOLD
Electrician’s / HVAC Multimeter
600A ACClamp w/ Temperature
600A AC / DCTRMS Clamp w/ Temperature
Electrician’s / HVAC TRMS Multimeter
MEASUREMENT CL1300 CL2300
AC Current 600A 600A
DC Current no 600A
AC Voltage 750V 750V
DC Voltage 1000V 1000V
LCD Display 6000 6000
Audible Continuity â—Ź â—Ź
Resistance Range 60MΩ 60MΩ
HOLD Data Hold â—Ź â—Ź
AUTO Auto Ranging â—Ź â—Ź
Low Battery â—Ź â—Ź
Apo Auto Power-Off â—Ź â—Ź
Back Light â—Ź â—Ź
Work/Clamp Light â—Ź â—Ź
Frequency/Duty Cycle â—Ź â—Ź
Frequency Limit 499.9kHz 499.9kHz
Capacitance 6000ÎĽF 6000ÎĽF
Diode Test â—Ź â—Ź
Non Contact Voltage â—Ź â—Ź
MAX/MIN Min/Max â—Ź â—Ź
Magnetic Mount â—Ź â—Ź
Lead Storage â—Ź â—Ź
ÎĽ Micro Amps 0.1ÎĽA 0.1ÎĽA
Bar Graph â—Ź â—Ź
Temperature â—Ź â—Ź
TRMS True RMS no â—Ź
Safety Rating CAT IV 600V CAT IV 600V
Digital Clamps w/ Temperature CL 1300, CL 2300
Digital Multimeters w/ Temperature MM 1300, MM 2300
Digital Temperature LoggersDTL 302, DTL 304
DTL 304MM 2300CL 2300
DTL 302MM 1300CL 1300Dual Input Temperature Logger
Quad Input Temperature Logger
• IP67: Water Proof/Dust Resistant• Differential T1-T2• Data Logging• 9,999 Memory Positions• MIN, MAX, AVG & Hold
• IP67: Water Proof/Dust Resistant• Differential T1-T2 & T3-T4• Data Logging• 9,999 Memory Positions• MIN, MAX, AVG & Hold
J-type -346° to 2192°F K-type -328° to 2498°FT-type -418° to 752°FE-type -238° to 1832°F
• True RMS • Backlit Display & Worklight• Magnetic Mount & Lead Storage• Non-Contact Voltage Tester• Analog Bar Graph• Temperature
• Backlit Display & Worklight• Magnetic Mount & Lead Storage• Non-Contact Voltage Tester• Analog Bar Graph• Temperature
• True RMS Measurements • Backlit Display• Analog Bar Graph
• Backlit Display• Analog Bar Graph MEASUREMENT MM1300 MM2300
AC Voltage 1000V 1000V
DC Voltage 1000V 1000V
AC Current 10A 10A
DC Current 10A 10A
LCD Display 6000 6000
Audible Continuity â—Ź â—Ź
Resistance Range 60MΩ 60MΩ
AUTO/HOLD Auto Hold â—Ź â—Ź
Diode Test â—Ź â—Ź
Low Battery â—Ź â—Ź
Apo Auto Power-Off â—Ź â—Ź
Back Light â—Ź â—Ź
ÎĽ Micro Amps 0.1ÎĽA 0.1ÎĽA
Capacitance 6000ÎĽF 6000ÎĽF
RANGE Range Hold â—Ź â—Ź
AUTO Auto Ranging â—Ź â—Ź
Frequency Limit 499.9kHz 499.9kHz
MAX/MIN Min/Max â—Ź â—Ź
Bar Graph â—Ź â—Ź
Temperature -58 ~ 1832°F -58 ~ 1832°F
Frequency / Duty Cycle â—Ź â—Ź
Δ Relative Reading ● ●
Low Impedance no â—Ź
TRMS True RMS no â—Ź
Safety Rating CAT IV 600V CAT IV 600V
FEATURESJ,K,T&EThermocoupleTypes
DifferentialTemperature
DataLogging
9,999MemoryPositions
USBInterface(Software included)
ThermocoupleTemperatureOffset
MIN/MAX/Average/Hold
BacklitDisplay
ProbeStorage
Bootw/Stand&MagneticStrapMount
ComplianceRatingIP67
Test Leads Test LeadsThermocouple ThermocoupleBatteries BatteriesCarrying Pouch
Includes: Includes:
Carrying Pouch
HVA
C TE
ST
ING
EQ
UIP
ME
NT
HVA
C TE
ST
ING
EQ
UIP
ME
NT
TRMS
HOLD AUTO
MIN/MAX
TRMS
HOLD
Apo RANGE
AUTO
CAT
IVCAT 600V
1000V
600V
CAT
IVCAT
1000VThermocouples Magnetic
Hanger StrapUSB Power Adapter
Includes:
Batteries
Apo AVG
MIN/MAXIP67
HOLD
Electrician’s / HVAC Multimeter
600A ACClamp w/ Temperature
600A AC / DCTRMS Clamp w/ Temperature
Electrician’s / HVAC TRMS Multimeter
MEASUREMENT CL1300 CL2300
AC Current 600A 600A
DC Current no 600A
AC Voltage 750V 750V
DC Voltage 1000V 1000V
LCD Display 6000 6000
Audible Continuity â—Ź â—Ź
Resistance Range 60MΩ 60MΩ
HOLD Data Hold â—Ź â—Ź
AUTO Auto Ranging â—Ź â—Ź
Low Battery â—Ź â—Ź
Apo Auto Power-Off â—Ź â—Ź
Back Light â—Ź â—Ź
Work/Clamp Light â—Ź â—Ź
Frequency/Duty Cycle â—Ź â—Ź
Frequency Limit 499.9kHz 499.9kHz
Capacitance 6000ÎĽF 6000ÎĽF
Diode Test â—Ź â—Ź
Non Contact Voltage â—Ź â—Ź
MAX/MIN Min/Max â—Ź â—Ź
Magnetic Mount â—Ź â—Ź
Lead Storage â—Ź â—Ź
ÎĽ Micro Amps 0.1ÎĽA 0.1ÎĽA
Bar Graph â—Ź â—Ź
Temperature â—Ź â—Ź
TRMS True RMS no â—Ź
Safety Rating CAT IV 600V CAT IV 600V
Digital Clamps w/ Temperature CL 1300, CL 2300
Digital Multimeters w/ Temperature MM 1300, MM 2300
Digital Temperature LoggersDTL 302, DTL 304
DTL 304MM 2300CL 2300
DTL 302MM 1300CL 1300Dual Input Temperature Logger
Quad Input Temperature Logger
• IP67: Water Proof/Dust Resistant• Differential T1-T2• Data Logging• 9,999 Memory Positions• MIN, MAX, AVG & Hold
• IP67: Water Proof/Dust Resistant• Differential T1-T2 & T3-T4• Data Logging• 9,999 Memory Positions• MIN, MAX, AVG & Hold
J-type -346° to 2192°F K-type -328° to 2498°FT-type -418° to 752°FE-type -238° to 1832°F
• True RMS • Backlit Display & Worklight• Magnetic Mount & Lead Storage• Non-Contact Voltage Tester• Analog Bar Graph• Temperature
• Backlit Display & Worklight• Magnetic Mount & Lead Storage• Non-Contact Voltage Tester• Analog Bar Graph• Temperature
• True RMS Measurements • Backlit Display• Analog Bar Graph
• Backlit Display• Analog Bar Graph MEASUREMENT MM1300 MM2300
AC Voltage 1000V 1000V
DC Voltage 1000V 1000V
AC Current 10A 10A
DC Current 10A 10A
LCD Display 6000 6000
Audible Continuity â—Ź â—Ź
Resistance Range 60MΩ 60MΩ
AUTO/HOLD Auto Hold â—Ź â—Ź
Diode Test â—Ź â—Ź
Low Battery â—Ź â—Ź
Apo Auto Power-Off â—Ź â—Ź
Back Light â—Ź â—Ź
ÎĽ Micro Amps 0.1ÎĽA 0.1ÎĽA
Capacitance 6000ÎĽF 6000ÎĽF
RANGE Range Hold â—Ź â—Ź
AUTO Auto Ranging â—Ź â—Ź
Frequency Limit 499.9kHz 499.9kHz
MAX/MIN Min/Max â—Ź â—Ź
Bar Graph â—Ź â—Ź
Temperature -58 ~ 1832°F -58 ~ 1832°F
Frequency / Duty Cycle â—Ź â—Ź
Δ Relative Reading ● ●
Low Impedance no â—Ź
TRMS True RMS no â—Ź
Safety Rating CAT IV 600V CAT IV 600V
FEATURESJ,K,T&EThermocoupleTypes
DifferentialTemperature
DataLogging
9,999MemoryPositions
USBInterface(Software included)
ThermocoupleTemperatureOffset
MIN/MAX/Average/Hold
BacklitDisplay
ProbeStorage
Bootw/Stand&MagneticStrapMount
ComplianceRatingIP67
Test Leads Test LeadsThermocouple ThermocoupleBatteries BatteriesCarrying Pouch
Includes: Includes:
Carrying Pouch
HVA
C TE
ST
ING
EQ
UIP
ME
NT
HVA
C TE
ST
ING
EQ
UIP
ME
NT
TRMS
HOLD AUTO
MIN/MAX
TRMS
HOLD
Apo RANGE
AUTO
CAT
IVCAT 600V
1000V
600V
CAT
IVCAT
1000VThermocouples Magnetic
Hanger StrapUSB Power Adapter
Includes:
Batteries
Apo AVG
MIN/MAXIP67
HOLD
Innovative Features...Superior Value
See our complete line of Test and Measurement products at
www.kleintools.com
IR 300030:1 Infrared ThermometerDual Laser Targeting
30:1 Infrared ThermometerIR 3000
• Distance to Spot 30:1• -76˚ ~ 1400˚F (-60 ~ 760˚C)• K-Type thermocouple Input• Dual Lasers allow you
to see the actual target diameter
FEATURES IR3000
Temperature Range-76~1400°F-60~760°C
K-Type Thermocouple Range-83.2~2552°F-64~1400°C
Dual Laser Targeting â—Ź
Emissivity 0.10~1.00
High/Low Alarms â—Ź
Backlit Display â—Ź
Worklight â—Ź
°F/°C Button ●
Max / Min / Average / Differential MAX/MIN â—Ź
Auto Shut Off / Seconds Apo 60sec
Diameter at Spot
Distance to Object
0.5”1”
2”4”
15”30”60”120”
Electronic Voltage TestersET 100 & ET 200
Non-Contact Voltage TestersNCVT-1 & NCVT-2
Features:• Measures AC and DC voltage at nine common levels up to 600V• Bright LED’s indicate voltage reading without batteries installed• Low impedance input reduces possibility of ghost voltages• Molded lead holders are perfect for easy measurments
of tamper proof outlets
Additional features for the ET200• Bright worklight to illuminate your work space• Audible continuity at less than 270kHz
Features:• Non-Contact voltage detection of voltage in cables, cords,
circuit breakers, light fixtures, switches, outlets and wires• When voltage is detected, a high intensity, bright red
LED illuminates and a warning tone sounds
Additional features for the NCVT-2• Automatically detects both low and standard voltages
CAT
IVCAT
CAT
IVCAT
V
V
ET200
ET100
© 2012 Klein Tools, Inc. Lincolnshire, IL. 60069-1418 Printed in U.S.A. 96125
600V
600VET100
NCVT-1
NCVT-2
ET200
Thermocouple Protective Boot Batteries Carrying Pouch
Includes:
Dual Range
HVA
C TE
ST
ING
EQ
UIP
ME
NT
Testing Equipment
HVAC
WARNING: Read, understand, and follow all instructions, cautions and warnings attached to and/or packed with all Test and Measurement devices before each use.
Apo MIN/MAX
Apo MIN/MAX
P R O F E S S I O N A L S E R I E S H V A C T E S T & M E A S U R E M E N T
Innovative Features...Superior Value
See our complete line of Test and Measurement products at
www.kleintools.com
IR 300030:1 Infrared ThermometerDual Laser Targeting
30:1 Infrared ThermometerIR 3000
• Distance to Spot 30:1• -76˚ ~ 1400˚F (-60 ~ 760˚C)• K-Type thermocouple Input• Dual Lasers allow you
to see the actual target diameter
FEATURES IR3000
Temperature Range-76~1400°F-60~760°C
K-Type Thermocouple Range-83.2~2552°F-64~1400°C
Dual Laser Targeting â—Ź
Emissivity 0.10~1.00
High/Low Alarms â—Ź
Backlit Display â—Ź
Worklight â—Ź
°F/°C Button ●
Max / Min / Average / Differential MAX/MIN â—Ź
Auto Shut Off / Seconds Apo 60sec
Diameter at Spot
Distance to Object
0.5”1”
2”4”
15”30”60”120”
Electronic Voltage TestersET 100 & ET 200
Non-Contact Voltage TestersNCVT-1 & NCVT-2
Features:• Measures AC and DC voltage at nine common levels up to 600V• Bright LED’s indicate voltage reading without batteries installed• Low impedance input reduces possibility of ghost voltages• Molded lead holders are perfect for easy measurments
of tamper proof outlets
Additional features for the ET200• Bright worklight to illuminate your work space• Audible continuity at less than 270kHz
Features:• Non-Contact voltage detection of voltage in cables, cords,
circuit breakers, light fixtures, switches, outlets and wires• When voltage is detected, a high intensity, bright red
LED illuminates and a warning tone sounds
Additional features for the NCVT-2• Automatically detects both low and standard voltages
CAT
IVCAT
CAT
IVCAT
V
V
ET200
ET100
© 2012 Klein Tools, Inc. Lincolnshire, IL. 60069-1418 Printed in U.S.A. 96125
600V
600VET100
NCVT-1
NCVT-2
ET200
Thermocouple Protective Boot Batteries Carrying Pouch
Includes:
Dual RangeH
VAC T
ES
TIN
G E
QU
IPM
EN
T
Testing Equipment
HVAC
WARNING: Read, understand, and follow all instructions, cautions and warnings attached to and/or packed with all Test and Measurement devices before each use.
Apo MIN/MAX
Apo MIN/MAX
P R O F E S S I O N A L S E R I E S H V A C T E S T & M E A S U R E M E N T