2
PN 4637502 March 2015 © 2015 Fluke Corporation. All rights reserved. 323/324/325 Clamp Meters Quick Reference Guide Warning To prevent possible electrical shock, fire, or personal injury, read the “323/324/325 Safety Sheet” before you use this Product. 300V CAT 600V CAT 300V CAT 600V CAT 325 TRUE RMS CLAMP METER 300V CAT 600V CAT 300V CAT 600V CAT 323 TRUE RMS CLAMP METER 300V CAT 600V CAT 300V CAT 600V CAT 324 TRUE RMS CLAMP METER 300V CAT 600V CAT 300V CAT 600V CAT 325 TRUE RMS CLAMP METER 300V CAT 600V CAT 300V CAT 600V CAT 325 TRUE RMS CLAMP METER 325 323, 324 300V CAT V V or >30 V V 323 V dc - 324, 325 V dc & V ac - V 323 V ac - 20 OFF ON V Hz AC DC A k MAXMIN F F C ON 323 324/325 ON 2:00 2:00 MIN MAX 300V CAT 600V CAT 300V CAT 600V CAT 325 TRUE RMS CLAMP METER 300V CAT 600V CAT 300V CAT 600V CAT 325 TRUE RMS CLAMP METER <70 323 324/325 <30 325 324 323

300V 323/324/325 CAT 300V CAT 600V CAT 300V Clamp Meters · 2019. 6. 28. · CAT 300V CAT 600V 325 TRUE RMS CLAMP METER HzV AC DC A k MAXMIN F C F 323 ON 324/325 ON 2:00 2:00 MIN

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 300V 323/324/325 CAT 300V CAT 600V CAT 300V Clamp Meters · 2019. 6. 28. · CAT 300V CAT 600V 325 TRUE RMS CLAMP METER HzV AC DC A k MAXMIN F C F 323 ON 324/325 ON 2:00 2:00 MIN

PN 4637502 March 2015© 2015 Fluke Corporation. All rights reserved.

323/324/325Clamp Meters

Quick Reference Guide

Warning

To prevent possible electrical shock, fire, or personal injury, read the “323/324/325 Safety Sheet” before you use this Product.

30

0V

CA

T6

00

VC

AT

30

0V

CA

T6

00

VC

AT

325

TR

UE

RM

S C

LA

MP

ME

TE

R

30

0V

CA

T6

00

VC

AT

30

0V

CA

T6

00

VC

AT

323

TR

UE

RM

S C

LA

MP

ME

TE

R

30

0V

CA

T6

00

VC

AT

30

0V

CA

T6

00

VC

AT

324

TR

UE

RM

S C

LA

MP

ME

TE

R

300 VCAT600 V

CAT

300 VCAT600 VCAT

325TRUE RMS CLAMP METER

300 VCAT600 V

CAT

300 VCAT600 VCAT

325TRUE RMS CLAMP METER

325

323, 324

300 VCAT600 V

CAT

300 VCAT600 V

CAT

300 VCAT

V Vor >30 V

V323 V dc -

324, 325V dc & V ac -

V323 V ac -

300 VCAT600 VCAT

325TRUE RMS CLAMP METER

20

OFF

ON

300 VCAT600 VCAT

325TRUE RMS CLAMP METER

VHz ACDC

Ak

MAXMIN

F

FC

ON323

324/325

ON

2:00

2:00

MINMAX

300 VCAT600 V

CAT

300 VCAT600 VCAT

325TRUE RMS CLAMP METER

300 VCAT600 V

CAT

300 VCAT600 VCAT

325TRUE RMS CLAMP METER

<70323324/325 <30

325

324

323

Page 2: 300V 323/324/325 CAT 300V CAT 600V CAT 300V Clamp Meters · 2019. 6. 28. · CAT 300V CAT 600V 325 TRUE RMS CLAMP METER HzV AC DC A k MAXMIN F C F 323 ON 324/325 ON 2:00 2:00 MIN

Electrical Specifications AC Current (Jaw)Range 323 . . . . . . . . 400.0 A 324, 325 . . . . (40.00, 400.0) AResolution 323 . . . . . . . . 0.1 A 324, 325 . . . . (0.01, 0.1) AAccuracy 323, 325 . . . . 2.0 % ±5 digits (45 – 65 Hz) 2.5 % ±5 digits (65 – 400 Hz) 324 . . . . . . . . 1.5 % ±5 digits (45 – 400 Hz)

Note: Add 2 % for position sensitivity. DC Current with Jaw (325)Range . . . . . . . . . . . (40.00, 400.0) A Resolution . . . . . . . . . . . (0.01, 0.1) AAccuracy . . . . . . . . . . . 2.0 % ± 5 digits

AC VoltageRange . . . . . . . . . . . 600.0 VResolution . . . . . . . . . . . 0.1 VAccuracy (45 – 400 Hz) . . 1.5 % ± 5 digits

DC VoltageRange . . . . . . . . . . . 600.0 V Resolution . . . . . . . . . . . 0.1 VAccuracy . . . . . . . . . . . 1 % ±5 digits ResistanceRange 323, 324 . . . . (400.0, 4000) Ω 325 . . . . . . . . (400.0, 4000, 40000) ΩResolution . . . . . . . . . . . (0.1, 1, 10) ΩAccuracy . . . . . . . . . . . 1 % ±5 digitsContinuity Beeper 323 . . . . . . . . ≤70 Ω 324/325 . . . . . ≤30 Ω

Capacitance (324, 325)Range . . . . . . . . . . . (100.0, 1000) µFResolution . . . . . . . . . . . (0.1, 1) µFAccuracy . . . . . . . . . . . 1 % ±4 digits Frequency with Jaw (325)Range . . . . . . . . . . . 5.0 to 500.0 HzResolution . . . . . . . . . . . 0.1 HzAccuracy . . . . . . . . . . . 0.5 % ±4 digitsTrigger Level . . . . . . . . . . 5 to 10 Hz, ≥10 A 10 to 100 Hz, ≥5 A 100 to 500 Hz, ≥10 A

Specifications

Contact Temperature (324, 325)Range . . . . . . . . . . . . . . -10.0 °C to 400.0 °CResolution . . . . . . . . . . . . . . 0.1 °CAccuracy . . . . . . . . . . . . . . 1 % ±8 digits

Note: Temperature uncertainty (accuracy) does not include error of the thermocouple probe.

Mechanical SpecificationsSize (L x W x H) . . . . . . . . . . (207 x 75 x 34) mmWeight 323 . . . . . . . . . . . 265 g 324 . . . . . . . . . . . 208 g 325 . . . . . . . . . . . 283 g

Environmental SpecificationsOperating Temperature . . . . . -10 °C to +50 °CStorage Temp . . . . . . . . . . . . -30 °C to +60 °C Operating Humidity . . . . . . . . Non Condensing (≤10 °C) ≤90 % RH (at 10 °C to 30 °C) ≤75 % RH (at 30 °C to 40 °C)

≤45 % RH (at 40 °C to 50 °C) (Without Condensation)Operating Altitude . . . . . . . . . 2000 metersStorage Altitude . . . . . . . . . . . 12,000 metersEMI, EMC Electromagnetic Compatibility . . . . . . . . . . . . . Applies to use in Korea only. Class A Equipment (Industrial Broadcasting & Communication Equipment) [1] [1] This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and is not to beused in homes.Temperature Coefficients . . . . Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C Over Voltage Category . . . . . CAT IV 300 V, CAT III 600 VSafety Compliance . . . . . . . . EN/IEC 61010-1, Pollution Degree 2 EN/IEC 61010-2-032 EN/IEC 61010-031:2002/A1:2008

Agency Approvals . . . . . . . . . Complies with CAN/CSA-C22.2 No. 61010-1, 2nd edition, including Amendment 1., , IP Rating . . . . . . . . . . . . . . IP 30 Per IEC 60529:2001; Non-operatingBatteries . . . . . . . . . . . . . . 2 AAA, NEDA 24A, IEC LR03

300V

CAT

600V

CAT

300V

CAT 600V

CAT

325

TRUE RMS CLAMP METER

300 V

300 VCAT600 VCAT

325TRUE RMS CLAMP METER

Hz

Hz

324, 325 325

AAA

300 VCAT600 V

CAT

300 VCAT600 VCAT

325TRUE RMS CLAMP METER

324, 325

HOLD

20 V30 V>

300 VCAT600 VCAT

325TRUE RMS CLAMP METER

300 VCAT600 VCAT

325TRUE RMS CLAMP METER

AC/DC & ZERO

AC/DC

ZERO

AC/DC

ZERO

AC/DC

ZERO2 sec