32
Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com Page 3001 July 2012 Grounding Equipment – 3000 Grounding Equipment Catalog 3000 September 2012

3000 Grounding

Embed Size (px)

Citation preview

Page 1: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t –

30

00

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Page 3001July 2012

Gro

un

din

g E

qu

ipm

en

t –

30

00

GroundingEquipment

Catalog 3000 September 2012

Page 2: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t – 30

00

Page 3002 July 2012

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

To indicate energized conditions on overhead lines, (from left) Chance Auto Ranging Voltage Indicator, Digital Voltage Detector and Multi-Range Voltage Detector. At far right, Energized Cable Sensor performs the same function on URD cable with an exposed concentric neutral and elbows without test points.See Catalog Section 2450, “Instruments and Meters,” for details and ordering information.

General Practices• Onde-energizeddistributionlines,ChancerecommendsDouble-Pointgrounding• Thisgroundingisatbothstructuresadjacenttoworksite:Connectallthreephasesviagroundset,thenconnectto

ground rod.• Plusapersonalgroundattheworksite,fromanyonephasetoaclusterbarwellbelowtheworker’sfeet• Onasystemwithoutaneutral,Chancerecommendsconnectingdownleadstoscrewgroundrodsinstalledatleast

20 feet from all structures and barricaded• OnlyformaintenancetasksduringwhichgroundsneednotbereplaceddoesChancefindacceptabletheSingle-Pointgroundingmethod(atonlytheworksite:Connectallphasestogetherandgroundingpluspersonalground,as above)

• Whereadequatephase-to-phaseclearancespermit,Chanceacceptsthepracticeofgroundingonlythephasebeingworked(inthesamemanneraspersonalground,above)

Temporary Grounding EquipmentSafe Working PracticesTherearemanyreasonsfortemporarygroundingtoprotectpersonnelworkingonde-energizedcircuits,including:

1.Inducedvoltagefromadjacentenergizedlines2.Fault-currentfeedoverfromadjacentlines3.Lightningstrikesanywhereonthecircuit4.Switching-equipmentmalfunctionorhumanerror5.Accident-initiatedcontactwithadjacentlines

Sinceanyoneoftheabovecouldresultinre-energizingthe circuit, most utilities treat these potential dangers asever-presentandimposestricttemporary-groundingworkrules.Theircrews’experienceoftenvoicesthesewatchwordsforthewisetoheed:“Ifyoucan’tseebothends,it’shot”and“Ifitisn'tgrounded,itisn’tdead.“

Vital Procedure RecommendationsStep One: Testing• Withatestinstrument,confirmthecircuittobeworkedhasbeende-energizedintentionallybeforegroundsetsare applied

Step Two: Cleaning• Foragoodconnection,scruboxidesandcontaminantsfromconductor,busworkorlatticecontactpoints

• Chanceuniversalwirebrushesmakethiseasy• Serrated-jawclampsalsoaidbypenetratingsurface

contaminants

Step Three: Connecting• ChanceinsulatedGrip-Allclampsticksarethepropertoolstoapplygroundingclamps

• VariousclampsticklengthsandstylesareavailableinCatalog Section 2100, “Insulated Hand Tools”

Reference:

Derived from ASTM F 855,Standard SpecificationsforTemporaryProtectiveGroundstobeUsed on De-energized Electric PowerLinesandEquipment

CopyrightASTMReprinted with

permission.

Grounding Set Ratings

Grade

ShortCircuitPropertiesA

ContinuousCurrent

Rating, A RMS,60 Hz

MinimumCable Size

with Ferrule Installed Equalor

Larger Than

WithstandRating,SymmetricalkARMS,60Hz

UltimateRating/Capacity,B

SymmetricalkARMS,60Hz

15cycles(250MS)

30cycles(500MS)

Copper CableSize

6cycles(100MS)

15 cycles(250MS)

30cycles(500MS)

60cycles(1 S)

1 14 10 #2 29 18 13 9 200 #22 21 15 1/0 48 30 21 15 250 1/03 27 20 2/0 61 38 27 19 300 2/04 34 25 3/0 76 48 34 24 350 3/05 43 30 4/0 96 60 43 30 400 4/0

6 54 39250kcmilor

two 2/0 114 72 51 36 450250kcmilor two 2/0

7 74 54350kcmilor

two 4/0 159 101 71 50 550350kcmilor two 4/0

AWithstandandultimateshortcircuitpropertiesarebasedonperformancewithsurgesnotexceeding20%asymmetryfactor(see Appendices X3 and X4, ASTM F 855).

B Ultimateratingrepresentsasymmetricalcurrentwhichtheclampshallcarryforthespecifiedtime.

Page 3: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t –

30

00

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Page 3003July 2012

1. Clamps

2. Ferrules 4. Support Stud

5. Shrink Tubing

3. Cable

Chance Grounding-Set Tester• Idealforperformingfunction

#5 above • Checkstheresistanceina

protective ground set • Canhelplocateproblemsoftenremediedbysimplerepairs

• How-tovideoisincludedwiththe tester

• SeeCatalogSection2450,“InstrumentsandMeters,”for details and ordering information

Safety Reviews• Temporarygroundingpracticesshouldbereviewedon

a regular basis• Aspartofatotalmaintenanceprogram,routine

reviews should be scheduled apart from sessions to set newpracticesforsystemupgradesandadditions

• Thesebasicsshouldbeincludedonareviewchecklist:1.Clampdesignsspecifictoeachapplication,2. Cable sized for fault-current potential (see table on page3002)andminimum-slacklengths

3. How construction affects placement of grounds4.Workproceduresoutlinedabove5. Inspect and test each grounding set

Selecting grounding clamps and cableTheChancegroundinglinecomprisesbothready-madesetsandseparatecomponentsforyourspecificneeds.Amongtheoptionsandcriteriatoconsider:• Functionalfit—Sizesoftheclamptypesinthissection

appear in ascending order of maximum-main-line size. Bydesign,manyclampsserveawidesizerangefortheirconductortype(cable,busortower)

• Adequatecapacity—Publishedratingsforbothclampsandcablemustwithstandmaximum-potentialsystem

fault-current magnitude and full-time duration. Certifiedtestreportsareavailableonrequest

• Coordinatedconnectors—Terminal(eitherpressure-typeorthreaded-type)selectedforclampsdictatesthecableferruletype(eitherplainorthreaded)tomatch

• On-sitehandling—Applicationclearancesandfit(foroverhead conductors and ground wires, transmission towershapes,URDapparatusorsubstationbuswork)affect clamp and cable dimensions

Installation information• Severaltrainingaidsavailableonrequest• Chancevideosandtechnicalmanualsprovidedetailsonproperinstallation• ConsultyourChancerepresentativeforanyadditionalassistance

How to order a Grounding SetInadditiontothespecifyingcriteriaabove,eachpartofagroundingsetrequirescertainchoices:1. Clamps • ASTMdesignationsforType,ClassandGradegiven

for clamps shown in this section2. Ferrules • Copperoraluminum • Plainorthreaded3. Cable • Lengthrequiredtoreachapplicationdistances • ASTMTypeIwithblackoryellowelastomerjackets

for temperatures from -40°F (-40°C) through +194°F (+90°C)

• ASTMTypeIIIwithclearthermoplasticjacketfortemperatures from +14°F (-10°C) through +140°F (+60°)shouldbeusedonlyinwell-ventilatedareas

4. Support Stud • Thisoptionrecommendedononlyoneclamptohelp

controlliftingthesettothefirstclampattachmentpoint

5.ShrinkTubing • Thistranslucentoptionrecommendedforstress

relief and inspection of cable strands between ferruleandjacket.

Page 4: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t – 30

00

Page 3004 July 2012

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

C-Type Grounding Clamps

C6001754Aluminum body,

Smooth jaws,Bronze eyescrew

with Acme threads, Tapped for 5⁄8-11 UNC

threaded ferrule

C6002275Aluminum body,

Smooth jaws,Bronze eyescrew

with Acme threads,Bronze pressure-type

terminals

C6002276Aluminum body,Serrated jaws,

Bronze eyescrewwith Acme threads,

Bronze pressure-type terminals

T6000790Bronze body,Smooth jaws,

Bronze T-handle/eyescrewwith fine threads,

Tapped for 5⁄8-11 UNC threaded ferrule

T6002708Aluminum body,Serrated jaws,

Bronze eyescrewwith Acme threads,

Tapped for 5⁄8-11 UNC threaded ferrule

C6001959Bronze body,Smooth jaws,

Bronze T-handle/eyescrewwith fine threads,

Tapped for 5⁄8-11 UNC threaded ferrule

C6001743Aluminum body,

Smooth jaws,Bronze eyescrewwith fine threads,

Tapped for 5⁄8-11 UNC threaded ferrule

T6000465Bronze body,Smooth jaws,

Bronze eyescrewwith fine threads,

Tapped for 5⁄8-11 UNC threaded ferruleor T6000466,

Drilled for 5⁄8-11 UNC threaded ferrule

C6002271Bronze body,Smooth jaws,

Bronze eyescrewwith fine threads,

Tapped for 5⁄8-11 UNC threaded ferrule

Catalog Number

C6001959 T6000465 T6000466 T6000790 C6002271 C6001754 C6002275 C6002276 T6002708 C6001743

ELECTRICALRATINGSContinuousCurrent(AMPS) 250 400 350 400 400 400 400

FaultCurrent-15Cycles(AMPS) 21,000 43,000 27,000 43,000 43,000 43,000 43,000

FaultCurrent-30Cycles(AMPS) 15,000 30,000 20,000 30,000 30,000 30,000 30,000

MECHANICALRATINGSRecommendedTorque(in.-lb.) 200 250 250 250 250 250 250

Main Line Range - Max.477kcmil

ACSR (0.814”)

1033kcmil ACSR

(1.25”)

750kcmil Str. Cu.

636kcmilACSR (0.998”)

1033kcmilACSR

(1.25”)

1033kcmil ACSR

(1.25”)

1033kcmilACSR

(1.25”)

1000kcmilCu. 1590kcmil

ACSR (1.50”)

Main Line Range - Min. #6 Sol. Cu. (0.162”)

#6 Sol. Cu. (0.162”)

#8 Sol. Cu. (0.128”)

#8 Sol. Cu. (0.128”)

#8 Sol. Cu. (0.128”)

#8 Sol. Cu. (0.128”)

#6 Sol. Cu. (0.162”)

Jumper Range - Max.1/0Grd.Cable w/Threaded

Stud

4/0Grd.Cable w/Threaded

Stud

2/0Grd.Cable w/Threaded

Stud

4/0Grd.Cable w/Plain Plug

4/0Grd.Cable w/Plain Plug

4/0Grd.Cable w/Threaded

Stud

4/0Grd.Cable w/Threaded

Stud

Jumper Range - Min.#2Grd.Cable w/Threaded

Stud

#2Grd.Cable w/Threaded

Stud

#2Grd.Cable w/Threaded

Stud

#2Grd.Cable w/Plain Plug

#2Grd.Cable w/Plain Plug

#2Grd.Cable w/Threaded

Stud

#2Grd.Cable w/Threaded

StudWeightEach 1 1/2lb./0.7kg. 2lb./0.9kg. 1lb./0.5kg. 1 1/4lb./0.6kg. 1 1/4lb./0.6kg. 1 1/4lb./0.6kg. 1 1/2lb./0.7kg.

ASTM DesignationTypeI Class A Grade2

TypeI Class A Grade5

TypeI Class A Grade3

TypeI Class A Grade5

TypeI Class B Grade5

TypeI Class B Grade5

TypeI Class A Grade5

Page 5: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t –

30

00

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Page 3005July 2012

C-Type Grounding Clamps

C6002281Aluminum body,

Smooth jaws,Bronze eyescrew

with Acme threadsBronze pressure-type terminal

C6002255Aluminum body,

Smooth jaws,Bronze eyescrew

with Acme threads, Tapped for 5⁄8-11 UNC threaded

ferrule

C6002282Aluminum body,Serrated jaws,

Bronze eyescrewwith Acme threads

Bronze pressure-type terminal

C6002256Aluminum body,Serrated jaws,

Bronze eyescrewwith Acme threads,

Tapped for 5⁄8-11 UNC threaded ferrule

*C6000386 has 1-1/4" x 6' Epoxiglas® Pole and total weight of 33⁄4 lb. (1.7 kg.).

T6003203Aluminum body,

Smooth jaws,Bronze eyescrew

with Acme threads,Tapped for 5⁄8-11 UNC

threaded ferrule

T6000658Aluminum body,

Smooth jaws,Bronze eyescrew

with Acme threads,Drilled for 5⁄8-11 UNC

threaded ferrule

Catalog Number C6002281 C6002255 C6002282 C6002256 *C6000386 G36051 T6003203 T6000658

ELECTRICALRATINGS

Continuous Current (amps) 400 400 400 400 400 400 400 400

FaultCurrent-15Cycles(amps) 43,000 43,000 43,000 43,000 43,000 43,000 43,000 43,000

FaultCurrent-30Cycles(amps) 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000

MECHANICALRATINGS

RecommendedTorque(in.-lb.) 250 250 250 250 250 250 250 250

Main Line Range - Max. 2"O.D.Bus 2"O.D.Bus 2"O.D.Bus 2"O.D.Bus 2"O.D.Bus 2"O.D.Bus 2"O.D.Bus 2"O.D.Bus

Main Line Range - Min. #6 Sol. Cu. (0.162”)

#6 Sol. Cu. (0.162”)

#6 Sol. Cu. (0.162”)

#6 Sol. Cu. (0.162”)

#6 Sol. Cu. (0.162”)

#6 Sol. Cu. (0.162")

#6 Sol. Cu. (0.162”)

#6 Sol. Cu. (0.162”)

Jumper Range - Max.4/0Grd.Cable

w/PlainPlug

4/0Grd.Cable

w/Threaded Stud

4/0Grd.Cable

w/PlainPlug

4/0Grd.Cable

w/Threaded Stud

4/0Grd.Cable

w/PlainPlug

4/0Grd.Cable

w/PlainPlug

4/0Grd.Cable

w/Threaded Stud

4/0Grd.Cable

w/Threaded Stud

Jumper Range - Min. #2Grd.Cable w/PlainPlug

#2Grd.Cable w/Threaded

Stud

#2Grd.Cable w/PlainPlug

#2Grd.Cable w/Threaded

Stud

#2Grd.Cable w/PlainPlug

#2Grd.Cable w/PlainPlug

#2Grd.Cable w/Threaded

Stud

#2Grd.Cable w/Threaded

Stud

WeightEach 2lb./0.9kg. 13⁄4lb./0.8kg. 2lb./0.9kg. 13⁄4lb./0.8kg. * 13⁄4lb./0.8kg. 13⁄4lb./0.8kg. 13⁄4lb./0.8kg.

ASTM DesignationTypeI Class A Grade5

TypeI Class A Grade5

TypeI Class B Grade5

TypeI Class B Grade5

TypeII Class B Grade5

TypeI Class A Grade5

TypeI Class A Grade5

TypeI Class A Grade5

G36051 Aluminum body,

Smooth jaws,Bronze eyescrew

with Acme threads,Bronze pressure-type terminal

C6000386*Mounted Clamp Aluminum body,Serrated jaws,

Bronze eyescrewwith Acme threads,

Bronze pressure-type terminal

Page 6: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t – 30

00

Page 3006 July 2012

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

†Rating with twin-grounding cables.

C6000337Aluminum body,

Smooth jaws,Bronze eyescrew

with Acme threads,Bronze pressure-type terminal

G3369Aluminum body,

Smooth jaws,Bronze eyescrew

with Acme threads,Bronze pressure-type terminal

C6000375Aluminum body,Serrated jaws,

Bronze eyescrewwith Acme threads,

Dual drilled for 5⁄8-11 UNC threaded ferrule

C6001733Aluminum body,

Smooth jaws,Bronze eyescrew

with Acme threads, Tapped for 5⁄8-11 UNC threaded ferrule

G33672Aluminum body,

Smooth jaws,Bronze eyescrew

with Acme threads,Bronze pressure-type threads

Bus-Bar Grounding Clamps:

C-Type Grounding Clamps

Catalog Number G33672 C6001733 C6000375 G3369 C6000337

ELECTRICALRATINGS

ContinuousCurrent(AMPS) 400 400 400 400 400

FaultCurrent-15Cycles(AMPS) 43,000 43,000 †70,000 43,000 43,000 †60,000

FaultCurrent-30Cycles(AMPS) 30,000 30,000 †50,000 30,000 30,000 †60,000

MECHANICALRATINGS

RecommendedTorque(in.-lb.) 250 250 300 300 300

Main Line Range - Max. 2-1⁄2”O.D.Bus 2-1⁄2”O.D.Bus 3”O.D.Bus 4”x4”Square 4.5”O.D.Bus 6-5⁄8”O.D.Bus

Main Line Range - Min. #4 Str. Cu. (0.232”)

#4 Str. Cu. (0.232”)

0.50”O.D. Bus

4/0 Str. Cu. (0.500”) 3-1⁄2”O.D.Bus

Jumper Range - Max. 4/0Grd.Cable w/PlainPlug

4/0Grd.Cable w/Threaded Stud

4/0Grd.Cable w/Threaded Stud

4/0Grd.Cable w/PlainPlug

4/0Grd.Cable w/PlainPlug

Jumper Range - Min. #2Grd.Cable w/PlainPlug

#2Grd.Cable w/Threaded Stud

#2Grd.Cable w/Threaded Stud

#2Grd.Cable w/PlainPlug

#2Grd.Cable w/PlainPlug

WeightEach 2-3⁄8lb./1.1kg. 2-3⁄8lb./1.1kg. 3lb./1.4kg. 5-1⁄4lb./2.4kg. 6lb./2.7kg.

ASTM DesignationTypeI Class A Grade5

TypeI Class A Grade5

TypeI Class B Grade7

TypeI Class A Grade5

TypeI Class A Grade6

Page 7: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t –

30

00

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Page 3007July 2012

*HG37061 has 11⁄4" x 6' Epoxiglas® Pole and total weight of 31⁄2 lb. (1.6 kg.).

HG37061*Mounted ClampAluminum body,

Smooth jaws,Bronze eyescrewwith fine threads,

Bronze pressure-type terminal

T6000806Aluminum body,Serrated jaws,

Bronze eyescrewwith fine threads,

Bronze pressure-type terminal

G36221Aluminum body,

Smooth jaws,Bronze eyescrewwith fine threads,

Bronze pressure-type terminal

G18102Aluminum body,

Bronze upper jaw,Smooth jaws,

Bronze eyescrewwith fine threads,

Bronze pressure-type terminal

Snap-On (Duckbill-type) Grounding Clamps

Catalog Number G18102 G36221 *HG37061 T6000806

ELECTRICALRATINGS

ContinuousCurrent(AMPS) 300 400 400 400

FaultCurrent-15Cycles(AMPS) 27,000 43,000 34,000 43,000

FaultCurrent-30Cycles(AMPS) 20,000 30,000 25,000 30,000

MECHANICALRATINGS

RecommendedTorque(in.-lb.) 250 250 300 300

Main Line Range - Max.250kcmilStr.Cu.

4/0 ACSR (0.574”)

566kcmilCu. 900kcmilACSR

(1.162”)

566kcmilCu. 900kcmilACSR

(1.162”)

1590kcmilACSR (1.625”)

Main Line Range - Min. #6 Sol. Cu. (0.162”)

#6 Sol. Cu. (0.162”)

#6 Sol. Cu. (0.162”) 0.5”

Jumper Range - Max. 2/0Grd.Cable w/PlainPlug

4/0Grd.Cable w/PlainPlug

4/0Grd.Cable w/PlainPlug

4/0Grd.Cable w/PlainPlug

Jumper Range - Min. #2Grd.Cable w/PlainPlug

#2Grd.Cable w/PlainPlug

#2Grd.Cable w/PlainPlug

#2Grd.Cable w/PlainPlug

WeightEach 1-1⁄2lb./0.6kg. 1-1⁄2lb./0.6kg. * 1-3⁄4lb./0.8kg.

ASTM DesignationTypeI Class A Grade3

TypeI Class A Grade5

TypeII Class A Grade4

TypeI Class B Grade5

Page 8: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t – 30

00

Page 3008 July 2012

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

*C6000198 has 11⁄4" x 6' Epoxiglas® Pole and total weight of 31⁄2 lb. (1.6 kg.).

Snap-On (Duckbill-type) Grounding Clamps

C6001734Aluminum body,

Smooth jaws,Bronze eyescrewwith fine threads,

Tapped for 5⁄8-11 UNC threaded ferrule

C6000198*Mounted ClampAluminum body,Serrated jaws,

Bronze eyescrewwith Acme threads,

Tapped for 5⁄8-11 UNC threaded ferrule

C6000197Aluminum body,Serrated jaws,Bronze eyescrewwith Acme threads,Tapped for 5⁄8-11 UNC threaded ferrule

C6000434Aluminum body,Serrated jaws,

Bronze eyescrewwith fine threads,

Bronze pressure-type terminal

Catalog Number C6001734 *C6000198 C6000197 C6001757 C6000434

ELECTRICALRATINGS

ContinuousCurrent(AMPS) 400 400 400 400 400

FaultCurrent-15Cycles(AMPS) 43,000 43,000 43,000 43,000 43,000

FaultCurrent-30Cycles(AMPS) 30,000 30,000 30,000 30,000 30,000

MECHANICALRATINGS

RecommendedTorque(in.-lb.) 250 250 250 250 250

Main Line Range - Max.566kcmilCu. 900kcmilACSR

(1.162”)

950kcmilCu. 1510kcmilACSR

(1.506”)

950kcmilCu. 1510kcmilACSR

(1.506”)2.5”

950kcmilCu. 1510kcmilACSR

(1.506”)

Main Line Range - Min. #6 Sol. Cu. (0.162”)

#6 Sol. Cu. (0.162”)

#6 Sol. Cu. (0.162”) 0.75” #6 Sol. Cu.

(0.162”)

Jumper Range - Max. 4/0Grd.Cable w/Threaded Stud

4/0Grd.Cable w/Threaded Stud

4/0Grd.Cable w/Threaded Stud

4/0Grd.Cable w/Threaded Stud

4/0Grd.Cable w/PlainPlug

Jumper Range - Min. #2Grd.Cable w/Threaded Stud

#2Grd.Cable w/Threaded Stud

#2Grd.Cable w/Threaded Stud

#2Grd.Cable w/Threaded Stud

#2Grd.Cable w/PlainPlug

WeightEach 1-1⁄2lb./0.7kg. * 1-1⁄2lb./0.7kg. 2-1⁄4lb./1.0kg. 1-1⁄2lb./0.7kg.

ASTM DesignationTypeI Class A Grade5

TypeII Class B Grade5

TypeI Class B Grade5

TypeI Class A Grade5

TypeI Class B Grade5

C6001757Aluminum body,Smooth jaws,Bronze eyescrewwith fine threads,Tapped for 5⁄8-11 UNC threaded ferrule

Page 9: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t –

30

00

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Page 3009July 2012

Cluster Grounding Clamps

G38033-Cluster Set

with Snap-On (Duckbill-type) Aluminum-body clamps,

Smooth jaws, Bronze eyescrews with fine threads,and 3-phase Aluminum cluster bar

with Bronze Pressure-type terminals

G34053-Cluster Set

with C-Type Aluminum-body clamps,

Smooth jaws, Bronze eyescrews with Acme threads,and 3-phase Aluminum cluster bar

with Bronze Pressure-type terminals

ImportantNote:Cluster Sets are furnished as shown above. The center clamp is bolted to the cluster bar.

Typical fourth ground clamp(not included in 3-Cluster Set,

must be ordered as separate item)

These drawings illustrate how Cluster Sets are to be con-nected, with grounding cable and a fourth clamp which must be ordered separately.

For cable and ferrules, see page 3018-3019.

Catalog Number G3405 G3803

ELECTRICALRATINGS

ContinuousCurrent(AMPS) 350 400

FaultCurrent-15Cycles(AMPS) 27,000 34,000

FaultCurrent-30Cycles(AMPS) 20,000 25,000

MECHANICALRATINGS

RecommendedTorque(in.-lb.) 250 250

Main Line Range - Max.400kcmilStr.Cu. 636kcmilACSR

(.998”)

566kcmilCu. 900kcmilAC

Main Line Range - Min.#8 Sol. Cu.

(0.12”)#6 Sol. Cu. (0.162”)

Jumper Range - Max.2/0Grd.Cable w/PlainPlug

4/0Grd.Cable w/PlainPlug

Jumper Range - Min.#2Grd.Cable w/PlainPlug

#2Grd.Cable w/PlainPlug

WeightEach 4 1⁄2lb./2kg. 6 5⁄8lb./3kg.

ASTM DesignationTypeI Class A Grade3

TypeI Class A Grade4

Page 10: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t – 30

00

Page 3010 July 2012

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

C6001735Aluminum body,Serrated jaws,

Bronze eyescrewwith fine threads,

Tapped for 5⁄8-11 UNC threaded ferrule

G33633SJAluminum body,Serrated jaws,

Bronze eyescrewwith fine threads,

Bronze pressure-type terminal

Tower & Flat-Face Grounding Clamps

T6001798Aluminum body,Serrated jaws,

Bronze T-handlewith Acme threads,

Tapped for 5⁄8-11 UNC threaded ferrule

G33634SJAluminum body,Serrated jaws,

Bronze T-handlewith fine threads,

Bronze pressure-type terminal

C6002231Bronze body,

Serrated jaws,Bronze T-handle

with Acme threads,Drilled for 5⁄8-11 UNC threaded ferrule

or T6003195,Tapped for 5⁄8-11 UNC threaded ferrule

Catalog Number C6002232 G33633SJ C6001735 C6002231 G33634SJ T6001798

ELECTRICALRATINGS

ContinuousCurrent(AMPS) 400 400 400 400 400 400

FaultCurrent-15Cycles(AMPS) 43,000 27,000 27,000 43,000 27,000 27,000

FaultCurrent-30Cycles(AMPS) 30,000 20,000 20,000 30,000 20,000 20,000

MECHANICALRATINGS

RecommendedTorque(in.-lb.) 250 250 250 250 250 250

Main Line Range - Max. 11⁄2” Angles 11⁄2” Flat

11⁄2” Angles 11⁄2” Flat

11⁄2” Angles 11⁄2” Flat

11⁄2” Angles 11⁄2” Flat

11⁄2” Angles 11⁄2” Flat

11⁄2” Angles 11⁄2” Flat

Main Line Range - Min. 1⁄8” 1⁄8” 1⁄8” 1⁄8” 1⁄8” 1⁄8”

Jumper Range - Max. 4/0Grd.Cable w/Threaded Stud

2/0Grd.Cable w/PlainPlug

2/0Grd.Cable w/Threaded Stud

4/0Grd.Cable w/Threaded Stud

2/0Grd.Cable w/PlainPlug

2/0Grd.Cable w/Threaded Stud

Jumper Range - Min.#2Grd.Cable w/Threaded

Stud

#2Grd.Cable w/Plain Plug

#2Grd.Cable w/Threaded

Stud

#2Grd.Cable w/Threaded

Stud

#2Grd.Cable w/Plain Plug

#2Grd.Cable w/Threaded

Stud

WeightEach 2lb./0.9kg. 15⁄8lb./0.7kg. 11⁄2lb./0.7kg. 2lb./0.9kg. 15⁄8lb./0.7kg. 11⁄2lb./0.7kg.

ASTM DesignationTypeI Class B Grade5

TypeI Class B Grade3

TypeI Class B Grade3

TypeIII Class B Grade5

TypeIII Class B Grade3

TypeIII Class B Grade3

C6002232Bronze body,

Serrated jaws,Bronze eyescrew

with Acme threads,Drilled for 5⁄8-11 UNC threaded ferrule

or T6003196,Tapped for 5⁄8-11 UNC threaded ferrule

Page 11: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t –

30

00

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Page 3011July 2012

Tower & Flat-Face Grounding Clamps

G33631Bronze body,

Serrated jaws,Bronze eyescrewwith fine threads,

Bronze pressure-type terminal

C6000085Aluminum body and retainer,

Bronze scrubber-type contact pads,Bronze T-handle

with fine threads,Bronze pressure-type terminal

G33632Bronze body,

Serrated jaws,Bronze T-handle

with fine threads,Bronze pressure-type terminal

C6001783Bronze body,

Serrated jaws and retainers, Tapped for 5⁄8-11 UNC threaded ferrule

Catalog Number G33631 G33632 C6000085 C6001783

ELECTRICALRATINGS

ContinuousCurrent(AMPS) 400 400 400 400

FaultCurrent-15Cycles(AMPS) 27,000 27,000 43,000 43,000

FaultCurrent-30Cycles(AMPS) 20,000 20,000 30,000 30,000

MECHANICALRATINGS

RecommendedTorque(in.-lb.) 250 250 250 300

Main Line Range - Max. 11⁄2” Angles 11⁄2” Flat

11⁄2” Angles 11⁄2” Flat

4” Structural Angles

3⁄4” x 5”Angles or Flats

5⁄8” Rod

Main Line Range - Min. 1⁄8” 1⁄8”2” Structural

Angles1⁄8”

Jumper Range - Max. 2/0Grd.Cable w/PlainPlug

2/0Grd.Cable w/PlainPlug

4/0Grd.Cable w/PlainPlug

4/0Grd.Cable w/Threaded Stud

Jumper Range - Min. #2Grd.Cable w/PlainPlug

#2Grd.Cable w/PlainPlug

#2Grd.Cable w/PlainPlug

#2Grd.Cable w/Threaded Stud

WeightEach 21⁄2lb./1.1kg. 21⁄2lb./1.1kg. 33⁄4lb./1.1kg. 5lb./2.25kg.

ASTM DesignationTypeI Class B Grade3

TypeIII Class B Grade3

TypeIII Class B Grade5

TypeIII Class B Grade5

Page 12: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t – 30

00

Page 3012 July 2012

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Catalog Number G42291SJ †HG42296SJ

ELECTRICALRATINGS

ContinuousCurrent(AMPS) 400 400

FaultCurrent-15Cycles(AMPS) 43,000 43,000

FaultCurrent-30Cycles(AMPS) 30,000 30,000

MECHANICALRATINGS

RecommendedTorque(in.-lb.) 250 250

Main Line Range - Max. 954kcmilACSR (1.196”)

954kcmilACSR (1.196”)

Main Line Range - Min. #2 Cu. (.258”) #2 Cu. (.258”)

Jumper Range - Max. 4/0Grd.Cable w/PlainPlug

4/0Grd.Cable w/PlainPlug

Jumper Range - Min. #2Grd.Cable w/PlainPlug

#2Grd.Cable w/PlainPlug

WeightEach 2lb./0.9kg. 41⁄4lb./2.0kg.

ASTM DesignationTypeI Class B Grade5

TypeII Class B Grade5

†Mounted Clamps supplied with 11⁄4"x6'Epoxiglas®Pole.

All-Angle Grounding ClampsAluminum Bodies with Serrated Jaws

†HG42296SJ*Bronze Pressure Terminal(Clamp same as G42291SJ)

For installation ease, jaws pivot 75° left or right.

G42291SJ*Pressure Terminal

*Foradaptertoconverttothreadedterminal,seePage3019.

†HG422816SJ*Bronze Pressure Terminal

(Clamp same as G4228-10SJ)

C6001732 Tapped for 5⁄8-11 UNC

threaded ferrule

Catalog Number G422810SJ †HG422816SJ T6001693 C6001732

ELECTRICALRATINGS

ContinuousCurrent(AMPS) 400 400 400 400

FaultCurrent-15Cycles(AMPS) 43,000 43,000 43,000 43,000

FaultCurrent-30Cycles(AMPS) 30,000 30,000 30,000 30,000

MECHANICALRATINGS

RecommendedTorque(in.-lb.) 250 250 250 250

Main Line Range - Max. 2-1⁄2IPS (2.88”)

2-1⁄2IPS (2.88”)

2-1⁄2IPS (2.88”)

2-1⁄2IPS (2.88”)

Main Line Range - Min. #2 Cu. (.258”) #2 Cu. (.258”) #2 Cu. (.258”) #2 Cu. (.258”)

Jumper Range - Max. 4/0Grd.Cable w/PlainPlug

4/0Grd.Cable w/PlainPlug

4/0Grd.Cable w/Threaded Stud

4/0Grd.Cable w/Threaded Stud

Jumper Range - Min. #2Grd.Cable w/PlainPlug

#2Grd.Cable w/PlainPlug

#2Grd.Cable w/Threaded Stud

#2Grd.Cable w/Threaded Stud

WeightEach 31⁄4lb./1.5kg. 51⁄4lb./2.4kg. 31⁄4lb./1.5kg. 31⁄4lb./1.5kg.

ASTM DesignationTypeI Class B Grade5

TypeII Class B Grade5

TypeI Class B Grade5

TypeI Class B Grade5

†Mounted Clamps supplied with 11⁄4"x6'Epoxiglas®Pole.

T6001693 Tapped for 5⁄8-11 UNC threaded ferrule

(Two single serrated jaws,for pothead and bus applications)

G422810SJ*Bronze Pressure Terminal

*Foradaptertoconverttothreadedterminal,seePage3019.

Page 13: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t –

30

00

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Page 3013July 2012

Features & Applications• FlexiblecoverfitsonlyC6002102orT6002364ball-studs• MadewithsamematerialasChancelinehose• Nonconductivecovermayhelppreventflashoveronballstudsinstalledinenclosedswitchgear,switchyardsor substations

• Coverisnotintendedforpersonnelprotectionandshould not be considered as insulative cover-up equipment

• Resilientozone/corona-resistantthermo-plasticelastomer does not absorb water

• Specialformulationresistsaging/checkingandretainshigh-visibilityorangecolor

Grounding Stud Cover – fits onto 1" ball-studs of Apparatus Grounding Clamps above

Longstudshankacceptsmosttypesofgroundingclamps

Socketclampsprovidemulti-angle attachment of grounds

*Long Ball Stud T6002364 3" nominal shank lengthWeight, each: 3⁄4 lb./0.34 kg.

Clamp C6002300 withpressure terminal______

for plain-plug ferrule on #2 to 4/0 ground-

ing cable

Clamp C6002100Drilled for 5⁄8-11 UNC

threaded ferruleor

Clamp C6002101 Tapped for 5⁄8-11 UNC

threaded ferrule______for threaded stud ferrule

on #2 to 4/0 grounding cable

*StandardBall Stud C6002102

Weight, each:1⁄2 lb. / 0.23 kg.

*Ball-studsdonotinterchangewithsystemonpage3014.

• Forrestricted-spaceapplicationsandasatruck-groundingsystem,thiscompactdesigndeliversahigh-currentratingusuallyassociatedwithonlylargeclamps

• Appliestoawiderangeofswitchingequipment,including:

o Industrial metalclad gear o Substations – indoors and out o Distribution – overhead and underground• Fortrucks,a*ballstudpermanentlymountsoneachbody

• Forthree-phaselivefrontset,seepage3015• Twoclampstylesandthreeball-studlengthsadapttomanyapplications

• Clampbodies,eyescrewsand*ball-studsarebronzealloy

• Tin-platedball-studshavenominal1"-diameterballandstudtofitNEMAterminalpads

• Lockwasherandnutaresiliconebronze• ASTMDesignationofTypeI,ClassA,Grade5foranyof

these clamps is met if associated grounding-cable sets arefittedwith5⁄8"copperferrulesasonpage3019

Fault Current Ratings 43,000Amps—15cycles 30,000Amps—30cycles

Recommended Installing Torques:Eyescrew 250 inch-pounds *Ball Stud 300 inch-pounds

21⁄8"(1⁄2-13UNC)

41⁄4"

113⁄16"

7"

23⁄4"(1⁄2-13UNC)

315⁄16"

Clamp T6002320 Tapped for 5⁄8-11 UNC

threaded ferrule______for threaded stud ferrule

on #2 to 4/0 grounding cable

Weight, each clamp on this page: 1 lb. / 0.45 kg.

5⁄8" dia. shank

• Snap-fitkeepscoverin place

• 5⁄8"-I.D.loopattoppermits hot-line tools to “pop” it on and off

• Chancesiliconelubricant C4002320 orC4170287mayease installation and removal

3.3"

1" internal threads (1⁄2-13UNC)

5⁄8" dia. shank

Ball-and-socket design for multiple uses

Apparatus Grounding Clamps

*Female-ThreadBall Stud T6002867

5⁄8" dia. shank

Weight, each:1⁄2 lb./0.23 kg.

11⁄2"

Catalog No. Description WeightC4060416 GroundingStudCover 1 oz. (28 g.)

Page 14: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t – 30

00

Page 3014 July 2012

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Features & Applications• Fortemporarygroundingofundergrounddistribution• Cablewithjacketoverconcentricneutral,special

clamps help ensure contact with center conductor• Chisel-pointclampmain-linecapacityis1-1⁄2"• C-TypeclampinChiselSetsfitsconductorsfrom#6(0.162")to636kcmilACSR(0.998")

• Spike-pointclampmain-linecapacityis2-1⁄2"• C-typeclampinSpikeSetfitsconductorsfrom#6(0.162")to2"O.D.bus

• Screw-typecopper-cladgroundrodinsetsindicatedis24"longforeasyhandling

• Helix(spiral)andhandlearebronze• Eachsetincludes:o6-ft.of#2copperclear-jacketgroundcableand

ferruleso A penetrator clamp (choice of hardened-steel 1⁄2"-widechiselorconicalspike)

oC-typegroundingclamp

Three-Way Grounding Clamp for *ball-stud, conductors, busbars

Features & Applications• Bysupportingotherclampsinthree-phasesets,ball

studs reduce installation labor• Thiscancontributetosafetyandminimizethenumber

of clamp connections per conductor in an overhead grounding scheme

• *Ball-studsmountwithoutfurnishedwashersinholesof lower clamp boss

• Thetappedholesshipwithplasticplugs• Clampterminalistappedfor5⁄8"-11UNCthreaded-

stud ferrules on grounding cable from #2 through 4/0• Versatileclampservessuchtemporary-groundingusesas: oAtruck-groundingsystem oOnindustrialmetalcladswitchgear oSubstationbuswork,indoorsandout oOverhead,undergroundandsubstationswitches o Three-phase ground sets with special, multi-angle *ball studs

• Compactdesigndelivershigh-currentratingassociatedwith large clamps

• Forgroundingtrucksorotherequipment,*ballstudpermanentlymountsoneachbodywithfurnishedlockwasher,flatwasherandnut

• Removablestudhasrecessed-hexendfittingforthrough-mountingversatility

• Clampbodyisaluminum• Acme-threadedeyescrewand*ball-studarebronzealloy

• Tin-platedball-studhas20mm(0.788")diameterball,7⁄8"-hexfittingand1-1⁄2"-long1⁄2"-13threadstofitNEMA terminal pads

• ASTMDesignationofTypeI,ClassA,Grade5ismetifassociatedgrounding-cablesetsarefittedwithcopperferrules as on page 3018

Clamp Main Line Range• BareConductorsfrom#8Sol.Cu.through636ACSR• FlatBusbarthrough1⁄4"x1-1⁄4"maximum• Ball-Stud20mm(0.788")onlyFault current ratings: 43,000amps—15cycles 30,000amps—30cycles

Recommended Installing Torques:Eyescrew 250 inch-pounds *Ball Stud 300 inch-pounds

C6001625

T6002233

*Ball-studdoesnotinterchangewithsystemonpage 3013.

T6001922

C6001626

Penetrator clamps, ground sets for underground cable

Catalog No. Description Weight, eachC6002316 Three-WayClampBodyonly 11⁄2lb./0.68kg.

C6002317*20mm (0.788") diameter Ball

Studwithflatwasher,lockwasherand nut

3⁄8lb./0.2kg.

Catalog No. Description Weight, eachC6001626 Chisel Clamp only 13⁄4lb./0.8kg.P6001623P ReplacementChiselPoint 2oz./0.09kg.T6002234 Chisel Set withGroundRod 93⁄4lb./4.4kg.C6001625 Chisel Set withoutGroundRod 41⁄2lb./2kg.T6001922 SpikedClamponly 13⁄4lb./0.8kg.P6001969P ReplacementSpikePoint 2oz./0.09kg.T6002233 SpikedSetwithGroundRod 8lb./3.6kg.

Page 15: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t –

30

00

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Page 3015July 2012

Underground Distribution Grounding Sets

*For storage bag T6000865, see page 3021.

Fault current ratings:21,000ampsfor15cyclesor15,000ampsfor30cyclesC-clamps are Cat. No. T600-0466.• EachC-Clampsetincludes:oAthree-wayaluminumterminalblocko Four bronze ground clampsoThree6’lengthsof1/0copperclear-jacketgroundcablewiththreaded-studferrules

• Setincludes: oYellow-jacketedelbowforthevoltage-classindicatedbelow oSixfeetof1/0coppergroundingcablewithyellowjacket o Bronze ground clamp T6000466• Faultcurrentratingforeachset:10,000ampsfor10cycles

• SetincludesaloadbreakbushingandbronzegroundclampT6000466connectedbya4’yellow1/0cable• Tin-platedcopperconnectorjoinscabletobushing• Threadedcopperferruleconnectsthecabletotheclamp• Faultcurrentratingforeachset:10,000ampsfor10cycles

Temporary Grounding Sets for Live-Front Switches and Transformers

Fault current ratings:21,000ampsfor15cycles or15,000ampsfor30cyclesEachsetIncludes:• Afour-waybronzeterminalblock• One6’andthree4’lengthsof1/0copperclear-jacketgroundcablewith

shrouded plain-plug copper ferrules• Threealuminumgroundclampswithbronzeeyescrews(G33633SJ)• OnewithbronzeT-handle(G3363-4SJ)

Fault current ratings:27,000ampsfor15cyclesor20,000ampsfor30cycles• EachBall-Studsetincludes: oAthree-waycopperterminalblock o Four bronze ground clamps oThree6’lengthsof2/0copperclear-jacketgroundcablewiththreaded-studferrules

Grounding Elbow Sets for Single- or Three-Phase Switches & Transformers

Three-Phase Grounding Elbow Sets for Switches & Transformers• Eachofthesesetsconsistsof: oAthree-wayterminalblockassembly oThree6’lengthsof1/0coppergroundcablewithyellowjacket o A bronze ground clamp T6000466 oThreeyellowelbows• Faultcurrentratingforeachset:10,000ampsfor10cycles

Grounded Parking Bushing Sets for Single- or Three-Phase Switches & Transformers

Replacement Parts: Grounding Elbow ONLY

All Copper Connector ONLY Elbow Probes ONLY

T6002375ASTM Type III,

Class B, Grade 2

T6002246ASTM Type I,

Class A, Grade 3

Catalog No. *Application Weight, eachT6003091 15kV 8lb./3.6kg.T6003092 25&35kVsmallinterface 9lb./4.09kg.

C6000729 15kVset 4lb./1.80kg.T6002131 25&35kVsmallinterfaceset 6lb./2.7kg.C6001927 35kVlargeinterfaceset 8lb./3.63kg.

C6003102 15kVset 14.5lb./6.5kg.C6003103 25&35kVsmallinterfaceset 15lb./6.75kg.

PSC6003103003 35kVlargeinterfaceset 16lb./7.25kg.

215GEHSG 15kV-elbowonly 1.9lb./0.88kg.225GEHSG 25&35kVsmallinterface-elbowonly 2.0lb./0.9kg.235GEHSG 35kVlargeinterface-elbowonly 4.0lb./1.8kg.

200LUGC6 for1/0GroundingCable 1.8 oz./40 g.200LUGC7 for2/0GroundingCable 1.8 oz./40 g.

215LBP 15kVProbe 5.3 oz./150.3 g.225LBP 25kVProbe 7.0 oz./198.4 g.235LBP 35kVProbe 1.0lb./0.45kg.

C6000758 C-Clamp Set 15lb./6.8kg.

C6000758ASTM Type I,

Class A, Grade 2

T6002246 BallSocketSet 16.5lb./7.4kg.

T6002375 Flat-Face Clamp Set 15.5lb./7kg.

Page 16: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t – 30

00

Page 3016 July 2012

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

F

B

C

AD

E

Chance grounding clamps, ferrules and cable meet ASTM F 855.

1/0 Grounding Cable Set* (58 lb./26 kg.)Catalog No. T6003094 consists of:

#2 Grounding Cable Set* (44 lb./20 kg.)Catalog No. T6000641 consists of:

*For storage bag T600-0865, see page 3021.

Features & Applications• Thesecompletesetsofgroundclamps,cableand

accessories • Allequipmentneededformanytypesofdistributionstructuresineasy-to-usekitsFerrulesarefactorycrimped to the grounding cable

• EachkitcomeswithC6002276clamps• Canbeusedonconductorsrangingfrom#8to1033kcmilACSR

Thesekitsweredesignedforuseonthefollowingtypesofstructures: 7.2/12.5kV ........................A1 through C24 14.4/24.9kV ......................VA1 through VC9-3 46kV ..........................TP1throughTP5 69kV ..........................TS1 through TS3-2The tables below list the components completely assembled in eachoftheDistributionGroundingSets.

Overhead Distribution Grounding Setswith Pressure-Type Terminals

2/0 Grounding Cable Set* (60 lb./27 kg.)Catalog No. T6003095 consists of:

4/0 Grounding Cable Set* (77 lb./35 kg.)Catalog No. T6003096 consists of:

T6001549

G3370

G3626

C6002276

1033kcmilACSR(1.25")#8 Solid Copper (0.128")

Main Line RangeMaximumMinimum

Item Description Quantity InformationA Serratedjaw,"C"Clamp

Cat. No. C600227610 ForPlainPlugfer-

rulesB GroundClusterSupport 1 Cat. No. T6001549C #2CopperGroundCable

Cat. No. S644960 ft. 3 Cables 6 ft. long

1 Cable 12 ft. long1 Cable 30 ft. long

D #2PlainPlugFerrules 10 Cat. No. C6002626E Clamp Support Stud 3 Cat.No.G3626F ScrewGroundRod 1 Cat.No.G3370

Item Description Quantity InformationA Serratedjaw,"C"Clamp

Cat. No. C600227610 ForPlainPlugfer-

rulesB GroundClusterSupport 1 Cat. No. T6001549C 1/0CopperGroundCable

Cat. No. S756860 ft. 3 Cables 6 ft. long

1 Cable 12 ft. long1 Cable 30 ft. long

D 1/0PlainPlugFerrules 10 Cat. No. C6002627E Clamp Support Stud 3 Cat.No.G3626F ScrewGroundRod 1 Cat.No.G3370

Item Description Quantity InformationA Serratedjaw,"C"Clamp

Cat. No. C600227610 ForPlainPlugfer-

rulesB GroundClusterSupport 1 Cat. No. T6001549C 4/0CopperGroundCable

Cat. No. S645160 ft. 3 Cables 6 ft. long

1 Cable 12 ft. long1 Cable 30 ft. long

D 4/0PlainPlugFerrules 10 Cat. No. C6002629E Clamp Support Stud 3 Cat.No.G3626F ScrewGroundRod 1 Cat.No.G3370

Item Description Quantity InformationA Serratedjaw,"C"Clamp

Cat. No. C600227610 ForPlainPlugfer-

rulesB GroundClusterSupport 1 Cat. No. T6001549C 2/0CopperGroundCable

Cat. No. S645060 ft. 3 Cables 6 ft. long

1 Cable 12 ft. long1 Cable 30 ft. long

D 2/0PlainPlugFerrules 10 Cat. No. C6002628E Clamp Support Stud 3 Cat.No.G3626F ScrewGroundRod 1 Cat.No.G3370

Page 17: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t –

30

00

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Page 3017July 2012

C6002145Plain Eyescrew

C6002146T-handle/eyescrew

T6002408T-Stud Terminal

C6000862

Cutout Grounding ClampsFeatures & Applications• Bronzeclampusedtogroundbottomhingecontact

on cutouts used on distribution riser poles or where groundingisrequired

• Fitsthesecutouts: o Chance F2, F3, and C Cutouts oWestinghouseLDX,SouthernStatesB-80 o Southern States Series 63 oJoslyn;S&CTypeSX oMcGraw-EdisonLMO,andGEDurabute• Clampcanbeinstalledwithorwithoutgrounding

cable• Servesasawarningandhelpsavoidaccidentalclosing

of cutout• Clamp’sdrilledterminalacceptsthreaded-studcable

ferrules• AlsoacceptsthreadedL-StudandT-StudTerminals(3⁄4"

diameter bronze) for use with conventional ground-clamp cable sets

• FaultCurrentrating:20,000ampsfor30cycles

Switch Blade Grounding ClampsFeatures & Applications• Attachestemporarygroundtoopenswitchduringde-

energized maintenance• Helpskeepgroundleadawayfromenergizedswitchjaw

• ShapedtofitbladesofChanceTypeM3Disconnectswitches

• Drilledterminalacceptsthreaded-studferrulesongrounding cable from #2 through 4/0

• AlsoacceptsthreadedL-StudTerminal(3⁄4"diameterbronze) for use with conventional ground-clamp cable sets

ASTM Designation: TypeI,ClassA,Grade5Fault Current ratings: 30,000ampsfor30cycles 43,000ampsfor15cycleswith L-Stud Terminal: 20,000ampsfor30cyclesRecommended torque: 250 inch poundsMain Line Range: 3⁄4" x 1⁄8"flatthrough21⁄2" x 1⁄4"flat

C600-0785with T-Stud

C6000785

Catalog No. Description Weight, each

C6002145PlaineyescrewSwitch

Clamp 31⁄2lb./1.7kg.

C6002146 T-handle/eyescrewClamp 31⁄2lb./1.7kg.

C6000841 L-StudTerminalonly 1lb./0.5kg.

C6000841L-Stud Terminal

Page 18: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t – 30

00

Page 3018 July 2012

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

with Pressure-Type TerminalsFeatures & Applications• Forgroundingsubstationbuswhende-energizedfor

maintenance• Makesworkmen’sjobsaferandeasier• Largecapacitybusclampsareavailableinmounted

versions• Reachesanymanageableheight• Increasesworker’sliftingcapabilities• Plastisolcoated,ShepherdHookLiftStick,withblockandropeassembly

• Reducescapacityclampsonoverheadbus• Twosizesofmountedclampsareavailable: o C6000618has6-5⁄8"buscapacity,utilizinga

C6000337 ground clamp mounted on 1-1⁄4" x 9 ft. Epoxiglas®Pole

o C6000619has4"buscapacity,utilizingaG3369groundclampmountedon1-1⁄4"x8'10"Epoxiglas® Pole

• Cables,ferrulesandsmallgroundingclampsshouldbeorderedseparately

Accessories

C6000617— LiftHookAssembly,11⁄4"x8'8"Epoxiglas®

pole,includesblockandropeassembly.C6000620— 11⁄4"x12'ExtensionPole(middlesection).C6000621— 11⁄4"x8'BottomPole.

Substation Grounding Sets

• Epoxiglas®handle(42"x1-1⁄4")meetsOSHAelectricalrequirements

• Givesoperatorsufficientaddedreachneededtomakecontacts

• Contacthookof98%-conductiveCopperisdouble-bolted to handle

• T-handlealuminumgroundingclampwithserratedflat-facejawensuresproperbonding

• Jawsopento1-1⁄2"forattachmenttogroundedstructuralangles,flatsorrods

• Extra-flexible(1638strands)Coppergroundingcable,7ft.,withclearjacketfittedwithcopperterminalateachendgiveshighcurrent-carryingcapability

C6000619 C6000618

C6000617

C6000620Extension Pole

T6000891

Electro-Static PrecipitatorGrounding Tool SetSimple Safety Procedures• Drainsoffstaticchargesthatremainoncollector

plates after electrostatic-precipitator pollution-control equipmentisde-energized

• Whenelectricalsystemofprecipitatorisde-energized: o First,securethetool’sgroundingclamptoaknown

ground o Next,useinsulatedhandletobringtheCopperhook

in contact with the precipitator collector plates o Contacthookhangsfromcollectorplates(withthe

grounding clamp still attached to ground) while service is performed on precipitator

o Whenmaintenanceiscompleted,useinsulatedhandletoremovecontacthookfromcollectorplates

o Finally,removethegroundclampbeforere-energizing the precipitator

C6000621Bottom Pole

Catalog Number C6000618 C6000619

ELECTRICALRATINGS

ContinuousCurrent(AMPS) 400 400

FaultCurrent-15Cycles(AMPS) 43,000 43,000

FaultCurrent-30Cycles(AMPS) 30,000 30,000

MECHANICALRATINGS

RecommendedTorque(in.-lb.) 250 250

Main Line Range - Max. 65⁄8” Angles 41⁄2” Angles

Main Line Range - Min. 41⁄2” Round Bus

1/0 Str. Copper (0.368”)

Jumper Range - Max. 4/0Grd.Cable w/PlainPlug

4/0Grd.Cable w/PlainPlug

Jumper Range - Min. #2Grd.Cable w/PlainPlug

#2Grd.Cable w/PlainPlug

WeightEach 10lb./4.5kg. 91⁄4lb./4.2kg.

ASTM DesignationTypeII Class A Grade5

TypeII Class A Grade5

Catalog No. Description Weight, eachT6000891 ElectrostaticGroundingSet 7lb./3.2kg.

Page 19: 3000 Grounding

Chance grounding ferrules and cable meet requirements of ASTM F 855; see table, page 3002.

Gro

un

din

g E

qu

ipm

en

t –

30

00

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Page 3019July 2012

Copper Grounding Cable Eitheraluminumorcopperferrulesmaybeusedwithcoppercable.

• Extra-flexibleforhandlingeaseyetstrongandtoughfor long wear

• Jacketingissmooth,abrasion,weatherandoilresistant• InaccordancewithapplicableASTMSpecifications,markedwithAWGsizeapproximatelyevery4feet

• YellowandblackjacketsareT-prenerubbercompoundwith -20°F recommended low temperature

• Clearjackets(whichallowvisualinspectionofstrandconditions)areultraviolet-inhibitedPolyVinylChloride(PVC)

• RecommendedlowtemperatureforPVC-jacketedcableis 0°F

• Extra-flexiblecables,becauseoftheirextra-finestrands• Requireterminationferruleswhenusedwithground

clamps

Selection Criteria• Shroudedferrulesoverlapontothegroundingcablejacketforstressrelieftotheterminal.Twocrimpssecure the ferrule against the bare strands and one crimpappliesonthejacket

• Unshroudedferrulesareavailablewithshrinktubingthatoverlapsthebarecableconductorandjacketforstress relief

• Availableeitherfactory-installedinpairsonanycablelengthspecifiedorasseparateindividualunits,theferrulesinstallsimplywithahydrauliccrimpingtool.Complete illustrated installation instructions come with the ferrules and include a table for the crimping die sizes to use

See ordering tables for crimping-die sizes applicable.Grounding FerrulesUnshrouded ferrules

Shrouded ferrules

Cable

Sect. B CableSection A

Plain-plug type for pressure-type grounding-clamp terminalsCopper ferrules

Threaded-stud type for tapped or drilled grounding-clamp terminals

Threaded-stud type for tapped or drilled grounding-clamp terminals

†Anderson die-less VERSA-CRIMP™ compression tools require no dies and are capable of making these crimped connections. If using another crimp tool brand, contact that manufacturer for Burndy die equivalents.

Tin-Plated Copper ferrulesPlain-plug type for pressure-type grounding-clamp terminals

Catalog Number

Size AWG Strands* Diameter

(Inches)Approx. O.D.

(Inches)Approx. Wt. (lb./1,000 ft.)

Yellow-Jacket Copper CableS6116 #2 665 0.32 0.55 280S6117 “1/0” 1045 0.41 0.66 425S6118 “2/0” 1330 0.47 0.73 520S6119 “4/0” 2109 0.59 0.87 760

Clear-Jacket Copper CableS6449 #2 665 0.344 0.53 289S7568 “1/0” 1050 0.445 0.63 520S6450 “2/0” 1323 0.487 0.70 546S6451 “4/0” 2107 0.616 0.84 841

Black-Jacket Copper CableS3713 #2 665 0.32 0.55 280S3715 “1/0” 1045 0.41 0.66 425S3712 “2/0” 1330 0.47 0.73 510S3714 “4/0” 2109 0.59 0.87 760

*Varies with manufacturer.

Shrouded plain copper ferrules1 unit each, not installed Catalog No.

Burndy Die No.† or equivalent

Cable Size, AWGSect. A Sect. B

C6002630 U165 U166 #2C6002631 U165 U168 “1/0”C6002632 U165 U-L “2/0”C6002633 U166 U-L “4/0”

Unshrouded plain copper ferrules1 unit each, not installed Catalog No.

Burndy Die No.† or equivalent

Cable Size, AWG

C6002614 U165 #2C6002615 U165 “1/0”C6002616 U165 “2/0”C6002617 U166 “4/0”

Shrouded threaded copper ferrulesC6002622 U165 U166 #2C6002623 U165 U168 “1/0”C6002624 U165 U-L “2/0”C6002625 U166 U-L “4/0”

Unshrouded threaded copper ferrulesC6002606 U165 #2C6002607 U165 “1/0”C6002608 U165 “2/0”C6002609 U166 “4/0”

Shrouded plain tin-plated copper ferrulesC6003119 U165 U166 #2C6003120 U165 U168 “1/0”C6003121 U165 U-L “2/0”C6003122 U166 U-L “4/0”

Unshrouded plain tin-plated copper ferrulesC6003111 U165 #2C6003112 U165 “1/0”C6003113 U165 “2/0”C6003114 U166 “4/0”

Shrouded threaded tin-plated copper ferrulesC6003115 U165 U166 #2C6003116 U165 U168 “1/0”C6003117 U165 U-L “2/0”C6003118 U166 U-L “4/0”

Unshrouded threaded tin-plated copper ferrulesC6003107 U165 #2C6003108 U165 “1/0”C6003109 U165 “2/0”C6003110 U166 “4/0”

Two crimps

Page 20: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t – 30

00

Page 3020 July 2012

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Threaded-stud type for tapped or drilled grounding-clamp terminals

1 unit each,not installedCatalog No.C6002618C6002619C6002620C6002621

Burndy Die No.†

or equivalentCableSize,AWG

#21/02/04/0

Sect. AU165U165U165U249

Sect. BU166U168U-LU-L

Shrouded threaded aluminum ferrules

1 unit each,not installedCatalog No.C6002626C6002627C6002628C6002629

Burndy Die No.†

or equivalentCableSize,AWG

#21/02/04/0

Sect. AU165U165U165U249

Sect. BU166U168U-LU-L

Shrouded plain aluminum ferrulesPlain-plug type for pressure-type grounding-clamp terminals

Aluminum ferrules

Shrink tubing for plain ferrulesFeatures & Applications• Clearheat-shrinktubeslimitcorrosion• Excludesmoisture•Stress-reliefforcablejacketandferrule-to-stranding connection

Part No.P6001593PP6001982PP6002069P

1 unit each,not installedCatalog No.C6002610C6002611C6002612C6002613

CableSize,AWG

#21/02/04/0

Burndy Die No.†

or equivalentU165U165U165U249

Unshrouded plain aluminum ferrules

1 unit each,not installedCatalog No.C6002602C6002603C6002604C6002605

CableSize,AWG

#21/02/04/0

Burndy Die No.†

or equivalentU165U165U165U249

Unshrouded threaded aluminum ferrules

• Visualinspectionofcablecondition through clear heat-shrinktubeallowsinspectionforbreakageorcorrosion that otherwise requirescontinuitytest

• Factory-assembledunitsexpose 1⁄2" of cable strands atjunctionpoint

Shrink tubing for threaded ferrulesFeatures & Applications• Clearheat-shrinktubeslimitcorrosion• Excludesmoisture•Stress-reliefforcablejacketandferrule-to-stranding connection

Lengths 5" 7" 9"

†Anderson die-less VERSA-CRIMP® compression tools require no dies and are capable of making these crimped connections. If using another crimp tool brand, contact that manufacturer for Burndy die equivalents.

†Anderson die-less VERSA-CRIMP® compression tools require no dies and are capable of making these crimped connections. If using another crimp tool brand, contact that manufacturer for Burndy die equivalents.

Factory-crimped, above

• Visualinspectionofcable condition through clearheat-shrinktubedeterminesbreakageorcorrosion that otherwise requirescontinuitytest

• Factory-assembledunitsexpose 1⁄2" of cable strandsatjunctionpoint

Factory-crimped, above

Part No.P6001593PP6001982PP6002069P

Lengths 5" 7" 9"

Features & Applications

Page 21: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t –

30

00

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Page 3021July 2012

Conversion TerminalsFeatures & Applications• Threaded-terminaladaptersforpressure-type

grounding-clamp terminals

• Simplyretrofitbolt-onadapterstoconvertclampswithpressure-typeterminalstoaccept5⁄8-11UNCthreadedferrules

Catalog NumberC6001584

“eyebolt”style,includesshakeproofwasher

and nutC6001700

includes steel retainerstraps for cable

Clamp Applications

CType,Snap-OnFlat-Face

All-Angle Clamps

C6001584

C6001700

Typical Application

Typical Application

Storage Bag for Temporary Grounding Clamps-and-Cable Sets

Features & Applications• Easy-to-see,bright-yellowprotectivebag• Madeofdoublevinyl-laminatedopen-weavenylon

cloth• Lightweightanddurablewithnylonstitching

throughout• Full-separatingclosureconstructedwithheavy-duty

snaps• Heavywebbinghandles• 18"Lx12"Wx15"D

Weight

3 lb.Catalog No.

T6000865

Description

GroundingStorageBag

Support StudsFeatures & Applications• CanbeinstalledonmostGroundClamps• Replacesrestrainingstrapimmediatelybelowterminal• Servesasamechanicalparkingstandforasecond

clamp• Helpsprevent"parked"clampfrommakingcontact

with conductor or ground• Particularlybeneficialinthree-phasegrounding

applications

Catalog No.G3626G3627

DescriptionStud for Rear MountStud for Side Mount

Size of Stud7⁄16" x 21⁄2"

7⁄16" x 3"

Weight1⁄2 lb./.2kg.3⁄4lb./.3kg.

G3627

G3626

Dielectric Compound No. 7Dielectric Compound No. 7, a silicone base material, is madeforusewithloadbreakdisconnectsandotherelectrical connecting and terminating devices.

Cat. No. C4170287..................................... 2 oz. Tube

Page 22: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t – 30

00

Page 3022 July 2012

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Cluster Barsfor wood, steel and concrete poles and tower anglesFeatures & Applications• Compact5"aluminum-alloybar(5⁄8"dia.)acceptsC-typeorduckbillclamps

• Forphase-to-phasegroundingtechnique• Adjustablewheelbinderand36"chainforpole

applications• Hookstyleforattachmenttotowerangles

Catalog No.T6001549T6001737

DescriptionPole-MountGroundingClusterBarTower-MountGroundingClusterBar

Weight71⁄2lb./4.09kg.9lb./4.09kg.

Cable Splicefor cables with plain-plug ferrules

Features & Applications• Useforsplicinggroundingcablewhenextensionsarerequired

• Thumbscrewmakesattachmenteasy

Catalog No.T6000252

DescriptionGroundingCableSplice

Splice fits #2 through 4/0 grounding cable with plain ferrules

Weight11⁄2 lb./0.7kg.

Terminal Blocks, 4-Wayfor cables with plain-plug ferrulesand threaded ferrules

Features & Applications• Attachgroundleadsfromgroundingclampstoa

common ground• Accommodates4/0groundingcables

T6000252

Cluster Support, 1-terminal typeFeatures & Applications• Hangsgroundingsetsonthepoletofacilitateliftingclamps—oneatatimetotheconductors

• Acceptsplainferruleson#2to4/0groundingcable• Copperbarlengthis11"

Catalog No.C6000152

DescriptionGroundClusterSupport

Weight91⁄2lb./4.3kg.

C6000152

T6001549

T6001549for poles only

T6001737(For tower angles only)

Catalog No.G47541

T6001964

Description4-WayTerminalBlocksforPlainPlugFerrules4-WayTerminalBlocksforThreadedFerrules

Weight2lb./0.9kg.1lb./0.45kg.

G47541for fourplain plug ferrules

T6001964for four 5⁄8-11 UNCthreaded ferrules

Page 23: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t –

30

00

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Page 3023July 2012

Storage Reel for Grounding Cable

Catalog No.G3370

DescriptionScrewGroundRod

Weight73⁄4 lb./3.5kg.

Features & Applications• Holeinouterflangeforcabletofeedthrough• Rewindhandlehasgalvanized-pipeextensionfortemporarilyparkingclamps

• Portablereelquicklypays-out/takes-up,• Helpskeepgroundsetscleanandneat,readyforuse• Handlesarecomfortable,turnedaluminum• Lightweightunitcanbecarriedtoremotesites• Tubular-steelframecanbeU-boltedtodeckoftruck• Galvanizeddrumhasribbedflangestoresistflexing

and beaded rims to eliminate sharp edges• Reelisforstorageonly• Cableandclampsshouldberemovedcompletelyfrom

reel before use• Failuretodosocouldresultinadangerousvoltage

drop and violent mechanical reactions• Alabelontheunitgivesthiswarning

Cable Size#21/02/04/0

ReelCapacity225 ft.185 ft.145 ft.100 ft.

Catalog No.C4176086

DescriptionPortableCableReel

Weight18lb./8kg.

Temporary Ground RodFeatures & Applications• ScrewGroundRodprovidesatemporaryground• Forwhenasystemgroundisnotavailable• Wheninstalled,6'spiraledgroundroddevelopsless

resistance than straight ground rods• Actualeffectivenessdependsuponsoilproperties• ReusableGroundRodiscopper-cladsteel• Helix(spiral)andhandlearebronze• Fortruck-groundingapplications,seekitbelow

Truck Grounding SetFeatures & Applications• Providesmeanstodrainoffcapacitanceorstatic

charges • Forwinchtrucksandaerialdevices• Flat-faceclampisforsecureattachmenttothetruck

bed at an area cleaned for electrical contact• C-typeclampisforsecureattachmenttogroundrod• Thisgroundingmethodshouldnotbeconsideredadequateprotectiontopersonnelagainstconductorcontact

• Fortruck-groundingwithball/socket-clamp,seepage3103

Truck Grounding SetCatalog No. T6001971

(total weight 35 lb./15.75 kg.)consists of:

ComponentScrewGroundRod

FlatFaceGroundClampC-TypeGroundClamp

#2CopperGroundingCable*Shrouded Alum. Ferrules

Storage Reel

Qty.111

50 ft.21

DescriptionCat.No.G3370,seeabove

Cat. No. T6001798, see page 3010Cat. No. C6001754, see page 3004

Cat. No. S6116, see page 3018Cat. No. C6002618, see page 3019

Cat. No. C4176086, see above

*Threadedferrulesarefactory-installedonendsofcable.

Page 24: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t – 30

00

Page 3024 July 2012

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Truck Safety Barricade

Features & Applications• Keepsworkersandonlookersawayfromtruckwhenitisbeingusedinproximitytoenergizedconductors

• Sixrods,madeofbrightorangeEpoxirod®, provide a 6-foot air space around the entire perimeter of the truck

• Safetybarricadealsoincludessixpiecesof3-inchlongsteeltubing(tobeweldedtotruckbythecustomer)

• Tubingholdsbarricaderods,150feetofyellowropeand a canvas storage bag

• Entirekitrequireslessstoragethantrafficconesandcanbequicklyinstalledandremovedateachjobsite

T3060006

DescriptionTruckSafetyBarricade

Catalog No.T3060006

Weight21lb./9.5kg.

Modulardesignquicklysetsupandtakesdownforstorage in rugged transport case.

Catalog No.C6001950

DescriptionGroundingSimulatorKit

Features & Applications• Demonstratesprinciplesfortemporarygrounding

practices• Portableinstructionalaidprovidesworkingmodelofthree-phasesystemcircuit

• Poweredbyastep-downtransformer• Plugsintoa110-volt60-cyclehouseholdsource• Speciallight/buzzerunitsimulateslineworkerin

maintenance on de-energized line• Insulatedwireswithalligatorclipateachendserveas

grounding cable and clamp sets (10 included)• Miniaturegroundingclusterbarisincludedforpole

mounting

Grounding Simulator Kit

Weight23lb./10.5kg.

Operation• Toquicklytestanyproposedconfiguration,depress

transformer foot switch to energize a fault on the system

• Ifthelightglowsandthebuzzersoundsonthe“worker,”thisindicatesthegroundingsysteminplacefails to provide protection

• Ifnosuchsignalsoccur,theschemeofgroundingconnectionsdoescreateaprotectivezoneofequalizedpotentialattheworksite

Ordering Information

Durable & Accurate• Durable,aluminumpipepoles• Woodcrossarms• Electricallycorrect,aluminumpoleseffecttheconductivitywhichshouldbeassumedforactualpoles

• Leadsfromthepolesandneutralconnecttogroundside on source (transformer)

Page 25: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t –

30

00

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Page 3025July 2012

Ground Set T6002841 included with Kits onlyConsists of 6 ft. long #2 cable with ferrules applied,BallSocketclamp(C6002100)andC-Typeclamp(T6000465)

Portable, lightweight, high performance• Aneasywaytohelpestablishanequipotentialzoneforalineworker• Forstandingonduringvariousenergizedandde-energizedworkpractices• Properlyapplied,itaccomplishescompliancewithOccupationalSafetyandHealthAdministration(OSHA)1910.269:

o “EquipotentialZone.TemporaryprotectivegroundsSHALLbeplacedat such locations and arranged in such a manner as to prevent each employeefrombeingexposedtohazardousdifferencesinelectricalpotential.”

• Canbetakenanywhereneeded,issimpletouse,maintainandstore• Consistsofahigh-ampacitytinned-copper-braidcablesewninagridpatternontoavinyl/polyesterfabric

• Cableterminalspermitconnectingmat'sgridinserieswithanelectricalgroundandsubjectsystemcomponentorvehicle

• Simplyrinsingwithwatercomprisesallthecarethematrequires• Matmaybefoldedandstoredinatoolbagtohelpkeepitcleanand

protected• Completeinstructionsareincludedwitheachunit

. . . continued on the next page . . .

Basic Equi-Mat® Personal Protective Ground GridEach Basic Unit includes a Long Ball Stud and illustrated instructions.

Catalog No. Single 1⁄4" Perimeter BraidPSC6003080*(Bucket) C6002850 C6002851 C6002852

Size

24" x 24" 58" x 58" 58" x 120" 120" x 120"

Weight 5lb./2.3kg.8lb./3.6kg.13lb./5.9kg.20lb./9.1kg.

KitCatalog No.C6002989C6002990C6002991

Equi-Mat® Personal Protective Ground Grid Size

58" x 58" 58" x 120" 120" x 120"

Weightper Kit

19lb./8.6kg.27lb./12.2kg.30lb./13.6kg.

Pre-Packaged KitsEach Pre-Packaged Kit includes Ground Grid (size below with Long Ball Stud and illustrated instructions) plus Ground Set T6002841 and Storage Bag C4170147.

Storage BagC4170147included with Kits onlyCatalog pages 2512-13

Long Ball Stud T6002364included with each Basic Equi-Mat® PersonalProtective Ground Grid (Catalog page 3013)

Accessory Items

Standard (Orange) Equi-Mat®

Personal Protective Ground GridFeatures & Applications• ComplieswithOSHA1910.269forequipotentialrequirementsnearvehicles,

underground gear, overhead switches and in substations• MeetsASTMF2715Standard

*Foruseinbottomofpersonnelbucketoflifttruck.

Page 26: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t – 30

00

Page 3026 July 2012

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Simple to join multiples for larger areas• Cascading(orjoiningtogether)twoormorematsiseasy

• Connectingtabandhardwarefurnishedwitheachmat

Features & Applications• ComplieswithOSHA1910.269• For equipotential requirements near vehicles,

underground gear, overhead switches and in substations

ApplicationsPadmounted Transformers and Switches• ComplieswithOSHA1910.269• Protectsworkersoperatingandmaintainingpadmounted

transformers and switchgear• ProperuseofEQUI-MATPersonalProtectiveGroundGridintheseapplicationscreatesanequipotentialzone

(Left) To join mats, conductive grids simply connect at tabs with bolt, washer and nut included with each mat. Tabs have shrink tube for stress relief. (Right) Ball stud can join mats and connect to ground set clamps.

Long ball stud accepts various grounding clamps as shown below and at right: Ball/Socket, C Type and Duckbill.

• Connectedinseries,theconductivegridsbecomeone• Forlargerarea,placelugconnectortabsoftwoadjacentmatsonthesuppliedboltorthreadedshankof a ball stud and secure with supplied washer and nut

• Thisisthesameasaclusterbar(chainbinder)doesinoverhead grounding practices

Bottom of Personnel Bucket on Lift Truck• Useonly24"x24"CatalogNo.PSC6003080

Mechanical Equipment (Vehicles, etc.) Grounding• ProvidescompliancewithOSHA1910.269• Protectsworkersaroundmechanicalequipmentwhichcould become energized, such as utility vehicles andportable generators

• For proper application, EQUI-MAT Personal ProtectiveGroundGridsareattachedtothevehicle(forexample)atlocationswhereworkerscouldcontactthevehicle

• Thisextendstheequipotentialareaaroundthevehicle

Overhead Distribution and Transmission Switches• EQUI-MAT Personal Protective Ground Grid can help

eliminate step and touch potential• Connectittothehandleofanoverheadswitchandstand

on it when opening or closing the switch

Line Apparatus Work• Similar uses for installing, maintaining or operatingregulators,reclosers,capacitorbanks

Suspect Substation Grids• Ifstationgroundmatintegrityisquestionable,applytheEQUI-MATPersonalProtectiveGroundGrid

Standard (Orange) Equi-Mat® Personal Protective Ground Grid

Page 27: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t –

30

00

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Page 3027July 2012

Slip-Resistant (Black) EQUI-MAT®

Personal Protective Ground GridFeatures & Applications• ComplieswithOSHA1910.269forequipotentialrequirementsnearvehicles,undergroundgear,overheadswitches

and in substations• MeetsASTMF2715Standard

Portable, lightweight, high performance• Aneasywaytohelpestablishanequipotentialzoneforalineworker

• Forstandingonduringvariousenergizedandde-energizedworkpractices

• Properlyapplied,itaccomplishescompliancewithOccupationalSafetyandHealthAdministration(OSHA)1910.269:

o “EquipotentialZone.TemporaryprotectivegroundsSHALL be placed at such locations and arranged in suchamannerastopreventeachemployeefrombeing exposed to hazardous differences in electrical potential.”

• Canbetakenanywhereneeded,issimpletouse,maintain and store

• Consistsofahigh-ampacitytinned-copper-braidcablesewninagridpatternontoavinyl/polyesterfabric

• Cableterminalspermitconnectingmat'sgridinserieswithanelectricalgroundandsubjectsystemcomponent or vehicle

• Simplyrinsingwithwatercomprisesallthecarethematrequires

• Matmaybefoldedandstoredinatoolbagtohelpkeepitcleanandprotected

• Completeinstructionsareincludedwitheachunit

Slip-Resistant Equi-Mat® Personal Protective Ground GridEach Unit includes Ground Grid, Long Ball Stud and illustrated instructions Catalog No. Single 1⁄4" Perimeter BraidPSC6003345PSC6003346PSC6003347

Size

58" x 58" 58" x 120" 120" x 120"

Weight 8lb./3.6kg.13lb./5.9kg.20lb./9.1kg.

KitCatalog No.PSC6003348PSC6003349PSC6003350

Equi-Mat® Personal Protective Ground Grid Size

58" x 58" 58" x 120" 120" x 120"

Weightper Kit

19lb./8.6kg.27lb./12.2kg.30lb./13.6kg.

Pre-Packaged Slip-Resistant Equi-Mat® KitsEach Kit includes Ground Grid (size below with Long Ball Stud and illustrated instructions) plusGround Set T6002841 and Storage Bag C4170147

Ground Set T6002841 included with Kits onlyConsists of 6 ft. long #2 cable with ferrules applied,BallSocketclamp(C6002100)andC-Typeclamp(T6000465)

Storage Bag C4170147included with Kits onlyCatalog pages 2512-13

Long Ball Stud T6002364included with each Basic Equi-Mat® PersonalProtective Ground Grid (Catalog page 3013)

Accessories

Slip-Resistant material• Forrain,snowandiceconditions• Nappedsurfaceofferssuperiorfooting• Fordryconditions,considertheStandard(Orange)

EQUI-MAT®PersonalProtectiveGroundGrid,availableinthesamesizesandkits

. . . continued on the next page . . .

Page 28: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t – 30

00

Page 3028 July 2012

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Features & Applications• ComplieswithOSHA1910.269forequipotentialrequirementsnearvehicles,undergroundgear,overheadswitches

and in substations

Simple to join multiples for larger areas• Cascading(orjoiningtogether)twoormorematsiseasy

• Connectingtabandhardwarefurnishedwitheachmat

Padmounted Transformers and Switches• ComplieswithOSHA1910.269• Protectsworkersoperatingandmaintainingpad-

mounted transformers and switchgear• ProperuseofEQUI-MATPersonalProtectiveGroundGridintheseapplicationscreatesanequipotentialzone

• Thisisthesameasaclusterbar(chainbinder)doesinoverhead grounding practices

(Left) To join mats, conductive grids simply connect at tabs with bolt, washer and nut included with each mat. Tabs have shrink tube for stress relief. (Right) Ball stud can join mats and connect to ground set clamps.

Long ball stud accepts various grounding clamps as shown below and at right: Ball/Socket, C Type and Duckbill.

• Connectedinseries,theconductivegridsbecomeone• Forlargerarea,placelugconnectortabsoftwoadja-centmatsonthesuppliedboltorthreadedshankofaball stud and secure with supplied washer and nut

Mechanical Equipment (Vehicles, etc.) Grounding• ProvidescompliancewithOSHA1910.269• Protectsworkersaroundmechanicalequipmentwhichcouldbecomeenergized,suchasutilityvehiclesandportable generators

• Forproperapplication,EQUI-MATPersonalProtectiveGroundGridsareattachedtothevehicle(forexample)atlocationswhereworkerscouldcontactthevehicle

• Thisextendstheequipotentialareaaroundthevehicle

Overhead Distribution and Transmission Switches• EQUI-MATPersonalProtectiveGroundGridcanhelp

eliminate step and touch potential• Connectittothehandleofanoverheadswitchand

stand on it when opening or closing the switch

Line Apparatus Work• Similarusesforinstalling,maintainingoroperatingregulators,reclosers,capacitorbanks

Suspect Substation Grids• Ifstationgroundmatintegrityisquestionable,applytheEQUI-MATPersonalProtectiveGroundGrid

Slip-Resistant (Black) EQUI-MAT®

Personal Protective Ground Grid

Page 29: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t –

30

00

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Page 3029July 2012

Rotating Ground Adapters for ReelsTested and Meets ASTM F 855 Standard

GR253X GR43BS2

< BronzeVise-typeconnectors

Ball-stud connectors>

Rotating Ground AdaptersPST6003438

Single Reel Grounding Set

Rotating Ground Adapters for Reels——————— Ordering Information ———————

Applications• ProvidesystemprotectionwhileconductorispulledfromreelsforstringingoperationsBydesign,thesystemaddsconductorgroundingbutdoesnotreplaceother grounding practices

• ThisincludesitemssuchasEqui-Mat® personal protective ground grids (Chance Catalog Section 3000)

• Systemservesasintendedpathtogroundforstaticdischarge and accidental energizing from downed lines,equipmentcontact,adjacentconductorsandlightning

Installation• RotatingGroundAdapterslidesonreelmandrelandthreelockingboltssecureit

• Outercollarcontactconnectstotheendoftheconductor from inside the reel

• Adapter’sinnercollarcontactconnectstoapermanentor screw-in ground rod (not included, see Chance Catalog Section 3000)

Catalog No. Rotating Grounding Adapters GR253X

GR43BS2

Single Reel Grounding SetPST6003438

Pipe Dia.Maximum

3-3/16"

2-11/16"

2-11/16"

Weight 9.8lb.(4.4kg.)

12.75 lb.

(5.8kg.)

53.75 lb.

(24.4kg.)

ASTM Grade:Fault Rating

ASTMGrade1:

14kA@15cycles

10kA@30cycles

ASTMGrade5:

43kA@15cycles

30kA@30cycles

Grade3:

27kA@15cycles

20kA@30cycles

(Ratings for this set are

limited to those for the

2/0 grounding cable.)

ConnectorType

BronzeViseType

Two 1"-diameter

Ball Studs

ConnectorRange

3 Sol. to 4/0 Str.

See Ball Stud

Clamp in Chance

Cat. Section 3000

Assembled Bill of Materials4ea.C6001754C-typegroundclamps,

2 ea. T6002320 ball stud ground clamps,

1ea.GR43BS2rotatinggroundadapter,

6 ea. Ferrules (aluminum),

6ea.Shrinktubes,

63ft.S6118yellowneoprene2/0cable

(1@50ft.,1@10ft.,1@3ft.)

Page 30: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t – 30

00

Page 3030 July 2012

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

NOTES

Page 31: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t –

30

00

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

Page 3031July 2012

NOTES

Page 32: 3000 Grounding

Gro

un

din

g E

qu

ipm

en

t – 30

00

Page 3032 July 2012

Phone: 573-682-5521 Email: [email protected] Web: hubbellpowersystems.com

NEVER COMPROMISE™

www.hubbellpowersystems.comSEPTEMBER2012 Catalog 3000

• 210 N. Allen St. • Centralia, MO 65240 • (573) 682-5521

NOTE:Hubbellhasapolicyofcontinuousproductimprovement.Wereservetherighttochangedesignandspecificationswithoutnotice.©Copyright2012HubbellIncorporated

NOTICE:ForthelatestrevisionofourCatalogandLiterature,clickhereorvisitourwebsite:www.hubbellpowersystems.com