4
KVA 562 KW 450 KVA 625 KW 500 Voltage V 440/254 Ampere A 819.7 Notes: ±5% TIF ±1% THF +25% -20% 6S 6S 0-5% adjustable 5% 0.5% +12% -10% 5S 5S Page 1/4 Alternator design Compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards Voltage Stable Time (100% Sudden Reduce) Voltage Stable Time (Sudden Increase) Frequency Reduce Frequency Regulation, Stead State Frequency Recovery Time (Sudden Increase) Sudden Frequency Warp (Sudden Increase) Frequency Recovery Time (100% Sudden Reduce) Voltage Regulation, Stead State Genset design comply to ISO8528/GB2820-97 Ripple flex exhaust pipe, exhaust siphon, flange, muffler Main line circuit breaker Telephone Influence Factor 50 2% Warranty Warranty is according to our standard conditions: a, 12 months, One year after installation; b, 1000 running hours (accumulated); subject to the earlier one.Service and parts are available from ENERGY360 or distributors in your location. Criterion Voltage Regulation 3 phase,60HZ@1800RPM Prime power 2) Available in following voltages:220/127,208/120,416/240,440/254,460/266,480/277 1) Ambient condition: 1,000 m,2524V charge alternator Standby power EngineCCEC Cummins KTA19-G3A3) Prime Power (PRP): Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97 eqv ISO8528; A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation. Standby Power Rating (ESP): The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating. Alternator: single bearing Stamford or Mecc Alte alternator IP23, insulation class H/H Radiator 40max, fans are driven by belt, with safety guard EYCS625 Performance Specification,Warranty and Criterion Performance Specification Features Dry type air filter, fuel filter, oil filter Absorber Standard automatic control panel User manual Sudden Voltage Warp (Sudden Increase) Frequency Waving Sudden Frequency Warp (100% Sudden Reduce) Batteries, rack and cable Sudden Voltage Warp (100% Sudden Reduce) Specifications may change without notice www.energy360.com.co

3 phase,60HZ@1800RPM - Energy 360 · Alternator design Compliance with GB755, BS5000, ... Number of Phase Connecting Type Number of Bearing ... Water Separator

  • Upload
    lamque

  • View
    221

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 3 phase,60HZ@1800RPM - Energy 360 · Alternator design Compliance with GB755, BS5000, ... Number of Phase Connecting Type Number of Bearing ... Water Separator

KVA 562

KW 450

KVA 625

KW 500

Voltage V 440/254

Ampere A 819.7

Notes:

≥±5% TIF≤±1% THF

≤+25%

≤-20%

≤6S

≤6S0-5% adjustable≤5%≤0.5%

≤+12%

≤-10%

≤5S

≤5S

Page 1/4

● Alternator design Compliance with GB755, BS5000,VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359standards

Voltage Stable Time (100% SuddenReduce)Voltage Stable Time (Sudden Increase)Frequency ReduceFrequency Regulation, Stead State

Frequency Recovery Time (SuddenIncrease)

Sudden Frequency Warp (SuddenIncrease)Frequency Recovery Time (100%Sudden Reduce)

Voltage Regulation, Stead State

● Genset design comply to ISO8528/GB2820-97

● Ripple flex exhaust pipe, exhaust siphon, flange, muffler● Main line circuit breaker

Telephone Influence Factor<50<2%

Warranty

Warranty is according to our standard conditions: a, 12 months, One year after installation; b, 1000 running hours (accumulated); subject to the earlier one.Service and parts are available from ENERGY360 or distributors in your location.

Criterion

Voltage Regulation

3 phase,60HZ@1800RPM

Prime power

2) Available in following voltages:220/127,208/120,416/240,440/254,460/266,480/2771) Ambient condition: 1,000 m,25℃

● 24V charge alternator

Standby power

● Engine(CCEC Cummins KTA19-G3A)

3) Prime Power (PRP): Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97(eqvISO8528); A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation.Standby Power Rating (ESP): The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. Nooverload, utility parallel or negotiated outage operation capability is available at this rating.

● Alternator: single bearing Stamford or Mecc Alte alternatorIP23, insulation class H/H )

● Radiator 40℃ max, fans are driven by belt, with safety guard

EYCS625

Performance Specification,Warranty and CriterionPerformance Specification

Features

● Dry type air filter, fuel filter, oil filter

● Absorber

● Standard automatic control panel ● User manual

Sudden Voltage Warp (SuddenIncrease)

Frequency WavingSudden Frequency Warp (100%Sudden Reduce)

● Batteries, rack and cable

Sudden Voltage Warp (100% SuddenReduce)

Specifications may change without notice

www.energy360.com.co

Page 2: 3 phase,60HZ@1800RPM - Energy 360 · Alternator design Compliance with GB755, BS5000, ... Number of Phase Connecting Type Number of Bearing ... Water Separator

CUMMINS STAMFORD

KTA19-G3A HCI 544D

Turbo, Water/Air cooling 3

PT type fuel pump, EFC “Y” type connecting

6 in line 1

18.9L 0.8

159*159 mm IP23

13.9:1 ≤1000m

Electronic Governor Brushless, self-exciting

≤1.5% H/H

E 594KVA

12VDC <50

<2%

100% load 29,3 ≤±1%

75% load 22,6 94.6%

50% load 16,2 1.035m3/s

1862L/s 6.23kPa

504℃ 716L/s

10kPa 11760L/s

50L 106L

≤4g/kwh 82-93℃

38L 104℃

345-483kPa

Page 2/4

EYCS625

Engine specification Alternator specification

Bore×Stroke

Model

Air Intake System

Fuel System

Brand

Cylinder Arrangement

Displacement

Compression Ratio

Governor Type

Frequency Regulation, Steady State:

Number of Phase

Connecting Type

Number of Bearing

Power Factor

Protection Grade

Altitude

Exciter Type

Brand

Model

Alternator Capacity

Telephone Influence Factor (TIF)

Air Intake System

Exhaust Gas Flow

Insulation Class, TemperatureRise

Alternator Efficiencies

Air Cooling Flow

THF

Voltage Regulation, Steady State

Starting system

Battery voltage

Fuelconsumption(GL/h)

Exhaust System

Max Intake Restriction

Burning Capacity

Intake Flow

Oil System Cooling System

Total Coolant Capacity

Thermostat

Max Water Temperature

Exhaust Temperature

Max Back Pressure

Total Oil Capacity

Oil Consumption

Engine Oil Tank Capacity

Oil Pressure at Rated RPM

Specifications may change without notice

www.energy360.com.co

Page 3: 3 phase,60HZ@1800RPM - Energy 360 · Alternator design Compliance with GB755, BS5000, ... Number of Phase Connecting Type Number of Bearing ... Water Separator

Page 3/4

Control system

Specifications may change without notice

EYCS625

www.energy360.com.co

● Comprehensive synchronising&loadsharing capabilities

● Built-in governor and AVR control

● Load switching (load sheddinganddummy load control)

● Mains (utility) de-couplingprotection

● Overload (kW & kV Ar) protection● Generator power (kW, kV Ar, kV A&pf) monitoring

● Unbalanced load protection

● Fuel usage monitor and low fuellevelprotection

● User configurable RS232, RS485andEthernet communicationse

● MODBUS RTU & TCP support

● Remote SCADA monitoring viavarious DSEsoftware applications● Fully configurable using DSEConfigurationSuite PC softwarevia USB

● Advanced SMS control and faultmessaging(additional GSMmodem required)

● Advanced Internal PLC editor allowsuserconfigurable functions to meetspecificapplication requirements.

● Sealed to IP65

Deepsea DSE8610 parallel controller (Option)Features:

● Security password-protectedprogramming levels

● Generator measurements (50/60Hz): U1-U3, I1-I3, Hz, kW, kVAr, kWh

Deepsea brand DSE6020 (Standard)Features:

● All parameters use digital modulation,abandoning analog modulation usingconventional electronic potentiometer,reliability and stability are increased

● Built-in watch dog can never be dead halt,ensuring smooth program execution

● Analog oil pressure, water temperature,fuel level, battery voltage, engine speed

● Auto start and Auto mains failurecontrol to the genset● Display of generator cumulatedelectric energy● Using microprocessor as a core,graphics LCD with big screen andbacklight

● PC and front panel configuration

● Built-in speed/frequency detectingunits can accurately judge the statessuch as crank success and over speed● Modular configuration design,inserted type connection terminals,flush type installation, compactstructure, easy installation

● 3 phase Generator protections:-Over-/under voltage-Over-/under frequency-Current/voltage asymmetry-Overcurrent/overload

Page 4: 3 phase,60HZ@1800RPM - Energy 360 · Alternator design Compliance with GB755, BS5000, ... Number of Phase Connecting Type Number of Bearing ... Water Separator

Page 4/4Specifications may change without notice

Soundproof Type Genset

Dimension: 4630×1660×2250 mm

Weight: 5800 kg

● Anti Condensation Heater

● Drop CT(For Paralleling)

Dimension: 3400×1258×2050 mm(With base fuel tank)

Weight: 4000 kg

Dimension and Weight

Open Type Genset

● Containerized Type● PMG

Data

● Heater

● Battery Charger

● Daily Fuel Tank ● Remote Control Panel

● Water Separator

Alternator Others

● Soundproof Type ● Engine Parts Drawing List

● Trailer Type ● Spare parts

● Auto Transfer Switch

● Paralleling System

EYCS625

Optional parts

Engine Fuel System Control System

● Fuel Level Sensor

ENERGY360 Carrera 42 #54a 71 Itagüi. PBX: (4)5600530E-mail:[email protected]

www.energy360.com.co