28
RBS 2964(FOR MU ONLY) / RBS 2216

2964

Embed Size (px)

Citation preview

Page 1: 2964

RBS 2964(FOR MU ONLY) / RBS 2216

Page 2: 2964

GSM Macro, high density,12TRX, indoor base station. Highly integrated (fewer cables and connections) and

compact, footprint-0.24sq.mm. Stacking one above other gives impressive ratio -

100TRX/Sq.meter. Total cost of ownership (TCO) is reduced as every

parameter’s performance is improved. Higher output with lesser power consumption. Can work in higher ambient temperature, reduction in fans

and cooling agents inside the shelter, room etc. Supports for both capacity and coverage requirements.

RBS 2964 Product Highlights

Page 3: 2964

RBS 2964- A glance

Page 4: 2964

Technical specifications

Page 5: 2964

900 system data

Page 6: 2964

1800 system data

Page 7: 2964

POWER options

Page 8: 2964

Power recommendations

Page 9: 2964

Power consumption

• Max. power consumption is <=5172w at 200-250VAC.

• Max power is consumed during the initial charging of batteries.

• All PSUs ( 3PSUS/cabinet) are recommended with 1500W each.

• PSU efficiency not <= 87%.

• Hence, (3x1500)/0.87~5172W.

Page 10: 2964

RBS2964/2216 consists of

1. ACCU-Alternating current connection unit(2216).

2. DCCU-Direct current connection unit(2216/2964).

3. Distribution Switch Unit-DXU-31(2216/2964).

4. Dual Radio Unit-DRU.(2964/2216)

5. Fan Control Unit –FCU.(2964/2216)

6. Internal Distribution Module- IDM.(2964/2216)

7. Power Supply Unit-PSU(2216)

8. Receiver Splitter.(2216)

9. Optional TMA Control Module-TMA-CM.(2216/2964)

Page 11: 2964

DXU-31

Supports:

1. System interface with 2/1.5Mbps links

2. Supports LAPD (Conc, Unconc and Mux)

3. Four Transmission ports( Port A,B,C and D), Multidrop

4. Radio network sync, through GPS receiver

5. TG sync through ESB.

6. Interfaces-T1-1.5Mbps/100ohms,

E1-2Mbps-100/120 ohms

Page 12: 2964

ACCU & IDM

• ACCU

Termination point for AC power

• Distributes power to all the PSUs

• Number of units-1

• IDM

• Supplies +24DC to the system

• Has fuses and breakers for protection

• Has +24V DC filter for battery connections

• Number of units-1

Page 13: 2964

PSU

• Gives +24VDC to the system.• Available in two versions.• PSU AC for

200~250VAC(Rectifier).• PSU DC for -48V system.

(converter dc to dc).• Number of units 0-3.• Additional units required to

reduce battery charging times.

Page 14: 2964

DRU-Dual Radio Unit

• Consists of• 2 GSM TRX• Hybrid combiner• 2 TX filter• 2 duplex filters• 2 bias injectors

• Number of units 1-6(12 TRX)

Page 15: 2964

DRU

• Supports• EDGE and GPRS in all time slots• TCC-Transmission Coherent combining, increased cell

radius for downlink

Page 16: 2964

RX splitter

• Shares the RX signals• Used for RX sharing with other

BTSs also.

Page 17: 2964

TMA control module

• Supplies power upto 6 TMAs• Monitors and Controls TMAs• Provides short circuit protection• Supervises cables

• Number of units 0~2

Page 18: 2964

BBS 2216

• Provides 4 hrs of battery back up for indoor site cabinet

• Has BFU, for supervision, connection and disconnection of batteries

Page 19: 2964

MODULAR FLEXIBILITY

Page 20: 2964

2 RBS stacked one above other

Page 21: 2964

RBS AND BBS stacked one above other

Page 22: 2964

SINGLE BAND CONFIG.

Page 23: 2964

Single band Two sector config.

Page 24: 2964

Single band three sectors

Page 25: 2964

DUAL BAND CONFIG 2 SECTORS

Page 26: 2964

DUAL BAND WITH 2 SECTORS

Page 27: 2964

DUAL BAND FOUR SECTORS

Page 28: 2964

DUAL BAND WITH 6 SECTORS