6
RevID ChID Change Name Date Plot Date: Drawn 139 Prices Circuit WORONORA 139 Prices Circuit, Woronora PROJECT NAME : DRAWING TITLE : Site: Project NO. DRAWING NO. A101 REVISION NO. Issue A - rev 2 Development Application NOTE The Builder shall check all dimensions and levels on site prior to construction. Notify any errors, discrepancies or omissions to the architect. Refer to written dimensions only. Do not scale drawings. Drawings shall not be used for construction purposes until issued for construction. This drawing reflects a design by Creative Home Designs and is to be used only for work when authorised in writing by Creative Home Designs. All boundaries and contours are subject to survey drawing W-01. All levels to Australian Height Data. It is the contractors responsibility to confirm all measurements on site and locations of any services prior to work on site. All documents here within are subject to Australian Copyright Laws. Project Partners Refer to consultant documentation when directed - BCA Consultant - TBC - Civil Engineer - TBC - Hydraulic Engineer - TBC - Landscape Designer - TBC - Mechanical Engineer - TBC - Structural Engineer - TBC - Surveyor - TBC 2/10/20 CHD101 Project Status CH Michele Dodd Client PLANS SITE PLAN MN BY D.P. 506541 APPROX. TRUE NORTH LINE BUILDING FORESHORE TIMBER PALING LOW METAL FENCE FENCED FENCE FIBRO FENCE STEEL MESH 8,776 1,440 9,407 2,795 1,600 1,500 2,795 Sediment control barrier Temporary fencing PROPOSED DECK TWO-STOREY BRICK RESIDENCE No. 139 PROPOSED PORCH DECK PROPOSED STUDIO PROPOSED LOFT GARAGE ADDITION EXISTING CARPORT EXISTING GARAGE Driveway 70.105 67.055 12.19 M H W M BRICK BOAT SHED SINGLE STOREY VINYL CLAD RESIDENCE No. 137 Timber Shed Timber Awning PRICES CIRCUIT B.M SSM 54682 RL 2.95 (A.H.D) Driveway 1 & 2 STOREY BRICK RESIDENCE No. 141 LOT 10 D.P 11327 path grassed grassed grassed garden garden garden grassed path conc. hardstand conc. hardstand WORONORA RIVER waste bins Construction material stockpile SITE ACCESS N 0. Site Plan 1:150 location map SITE CALCULATIONS: Site Area = 822.5m 2 Maximum Floor Area = 411.25m 2 Existing Dwelling Floor Area = 181m 2 Existing Garage Area = 25m 2 Proposed Dwelling Floor Area = 181m 2 Proposed Studio Floor Area = 34m 2 Proposed Loft Floor Area = 53m 2 Proposed Garage Floor Area = 63m 2 Gross Floor Area = 300m 2 (36%) Minimum Landscape Area = 329m 2 Proposed Landscape Area = 330m 2 STORMWATER: Connect new stormwater into an existing functioning system

25 Mirral Road, CARINGBAH SOUTH

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 25 Mirral Road, CARINGBAH SOUTH

RevID ChID Change Name DatePlot Date:Drawn

139 Prices CircuitWORONORA

139 Prices Circuit, WoronoraPROJECT NAME :

DRAWING TITLE :

Site:

Project NO.

DRAWING NO.

A101

REVISION NO.

Issue A - rev 2Development Application

NOTEThe Builder shall check all dimensions and levels on site prior to construction.Notify any errors, discrepancies or omissions to the architect. Refer to writtendimensions only. Do not scale drawings. Drawings shall not be used forconstruction purposes until issued for construction. This drawing reflects a designby Creative Home Designs and is to be used only for work when authorised inwriting by Creative Home Designs.

All boundaries and contours are subject to survey drawing W-01. All levels toAustralian Height Data. It is the contractors responsibility to confirm allmeasurements on site and locations of any services prior to work on site.

All documents here within are subject to Australian Copyright Laws.

Project PartnersRefer to consultant documentation when directed- BCA Consultant - TBC- Civil Engineer - TBC- Hydraulic Engineer - TBC- Landscape Designer - TBC- Mechanical Engineer - TBC- Structural Engineer - TBC- Surveyor - TBC

2/10/20CHD101

Project Status

CH

Michele DoddClient

PLANS

SITE PLAN

MN

BY D.P. 506541

APPROX. TRUE NORTH

LIN

E B

UIL

DIN

G

FOR

ES

HO

RE

TIMBERPALING

LOW METAL FENCE

FENCED FENCEFIBRO FENCESTEEL MESH

8,776

1,44

0

9,407

2,79

5

1,60

0

1,50

0

2,79

5

Sediment control barrier

Temporary fencing

PROPOSEDDECK

TWO-STOREYBRICK

RESIDENCENo. 139

PROPOSEDPORCH DECK

PROPOSEDSTUDIO

PROPOSEDLOFT

GARAGEADDITION

EXISTINGCARPORT

EXISTINGGARAGE

Driveway

70.105

67.055

12.1

9

MH

WM

BRICKBOAT SHED

SINGLE STOREYVINYL CLADRESIDENCE

No. 137

TimberShed

TimberAwning

PRIC

ES

C

IRC

UIT

B.M SSM 54682RL 2.95 (A.H.D)

Driveway

1 & 2 STOREYBRICK

RESIDENCENo. 141

LOT 10D.P 11327

path

grassed

grassed

grassed

garden

garden

garden

grassed

path

conc.hardstand

conc.hardstand

WO

RO

NO

RA

R

IVER

waste bins

Constructionmaterialstockpile

SITE ACCESS

This map has been produced with the most current data available to Council as supplied by various sources. INFORMATION IN THIS MAP IS SUBJECT TOCOPYRIGHT. Council is not responsible for any inaccuracies in the data provided. Contact Council’s Land Information Unit (ph. 9710 0116) for more information.

Sutherland Shire Council Mapping

128

Printed:

Metres

6,386Scale 1:

23/09/2020

2550

at A4

LegendLand Yellow

Land

N

0. Site Plan1:150

location map

SITE CALCULATIONS:Site Area = 822.5m2

Maximum Floor Area = 411.25m2

Existing Dwelling Floor Area = 181m2

Existing Garage Area = 25m2

Proposed Dwelling Floor Area = 181m2

Proposed Studio Floor Area = 34m2

Proposed Loft Floor Area = 53m2

Proposed Garage Floor Area = 63m2

Gross Floor Area = 300m2 (36%)

Minimum Landscape Area = 329m2

Proposed Landscape Area = 330m2

STORMWATER:Connect new stormwater into anexisting functioning system

Page 2: 25 Mirral Road, CARINGBAH SOUTH

RevID ChID Change Name DatePlot Date:Drawn

139 Prices CircuitWORONORA

139 Prices Circuit, WoronoraPROJECT NAME :

DRAWING TITLE :

Site:

Project NO.

DRAWING NO.

A102

REVISION NO.

Issue A - rev 2Development Application

NOTEThe Builder shall check all dimensions and levels on site prior to construction.Notify any errors, discrepancies or omissions to the architect. Refer to writtendimensions only. Do not scale drawings. Drawings shall not be used forconstruction purposes until issued for construction. This drawing reflects a designby Creative Home Designs and is to be used only for work when authorised inwriting by Creative Home Designs.

All boundaries and contours are subject to survey drawing W-01. All levels toAustralian Height Data. It is the contractors responsibility to confirm allmeasurements on site and locations of any services prior to work on site.

All documents here within are subject to Australian Copyright Laws.

Project PartnersRefer to consultant documentation when directed- BCA Consultant - TBC- Civil Engineer - TBC- Hydraulic Engineer - TBC- Landscape Designer - TBC- Mechanical Engineer - TBC- Structural Engineer - TBC- Surveyor - TBC

2/10/20CHD101

Project Status

CH

Michele DoddClient

PLANS

Ground Floor Layouts

179° 59' 00"

359° 59' 00"

98°

38'

0

0"

67.055 MHW

12.1

9

70.105 MHWM.

H.

W.

M.

SA

SA

ENTRYRL. 3.81

BATHROOM /LDRYRL. 38.1

BEDROOM 1RL. 38.1

LIVINGRL. 31.6

KITCHENETTERL. 31.6

LOUNGERL. 31.6

DECKRL. 29.7

linen

GARAGERL. 2.72

HWPORCHRL. 3.76

179° 59' 00"

359° 59' 00"

98°

38'

0

0"

67.055 MHW

12.1

9

70.105 MHWM.

H.

W.

M.

SA

SA

ENTRYRL. 3.81

BATHROOM /LDRYRL. 38.1

BEDROOM 1RL. 38.1

LIVINGRL. 31.6

KITCHENETTERL. 31.6

LOUNGERL. 31.6

DECKRL. 29.7

linen

GARAGERL. 2.72

HWPORCHRL. 3.76

179° 59' 00"

359° 59' 00"

98°

38'

0

0"

67.055 MHW

12.1

9

70.105 MHWM.

H.

W.

M.

4,500 280 7,900 90 2,660 90 1,800280

1,660 140

3,37

04,

400

2,701 1,800 280 3,270 90 1,410 110 3,300 110 4,250 280 1,660 140

140

3,46

014

03,

690

140

1,200 90 3,400 90 10,320 90

906,

420

903,

743

270

90 3,810 90 2,500 250 7,000 250

250

3,70

025

06,

143

270

4,02

090

2,31

0

1,50

090

1,53

090

0

280

2,46

090

4,66

028

0

3,55

011

01,

260

902,

200

2,200 90 1,010

SA

SA

ENTRYRL. 3.81

LDRYRL. 3.16

PANRTYRL. 3.81KITCHEN

RL. 3.81

BARRL. 3.81

LOUNGERL. 3.81

DININGRL. 3.81

CELLARRL. 3.81

linen

DECKRL. 3.27

STUDIORL. 2.9

BATHRL. 2.9

GARAGERL. 2.72

new

bea

m to

eng

inee

rs d

etai

l

HW

(bat

hroo

m)

(sta

ir)

(bar

)

(pan

try)

1.0m high wall

PORCHRL. 3.76

STORAGERL. 2.72

W.CRL. 3.81

1. Existing Ground Floor Layout1:100

2. Ground Floor Demolition Layout1:100

4 Ground Floor Layout1:100

Page 3: 25 Mirral Road, CARINGBAH SOUTH

RevID ChID Change Name DatePlot Date:Drawn

139 Prices CircuitWORONORA

139 Prices Circuit, WoronoraPROJECT NAME :

DRAWING TITLE :

Site:

Project NO.

DRAWING NO.

A103

REVISION NO.

Issue A - rev 2Development Application

NOTEThe Builder shall check all dimensions and levels on site prior to construction.Notify any errors, discrepancies or omissions to the architect. Refer to writtendimensions only. Do not scale drawings. Drawings shall not be used forconstruction purposes until issued for construction. This drawing reflects a designby Creative Home Designs and is to be used only for work when authorised inwriting by Creative Home Designs.

All boundaries and contours are subject to survey drawing W-01. All levels toAustralian Height Data. It is the contractors responsibility to confirm allmeasurements on site and locations of any services prior to work on site.

All documents here within are subject to Australian Copyright Laws.

Project PartnersRefer to consultant documentation when directed- BCA Consultant - TBC- Civil Engineer - TBC- Hydraulic Engineer - TBC- Landscape Designer - TBC- Mechanical Engineer - TBC- Structural Engineer - TBC- Surveyor - TBC

2/10/20CHD101

Project Status

CH

Michele DoddClient

PLANS

First Floor Layouts

179° 59' 00"

359° 59' 00"

98°

38'

0

0"

67.055 MHW

12.1

9

70.105 MHWM.

H.

W.

M.

SA

SA

LOUNGERL. 63.5

KITCHENRL. 63.5

BATHROOMRL. 63.5

BEDROOM 2RL. 63.5

BEDROOM 3RL. 63.5

SITTINGRL. 63.5

BALCONYRL. 61.6

179° 59' 00"

359° 59' 00"

98°

38'

0

0"

67.055 MHW

12.1

9

70.105 MHWM.

H.

W.

M.

SA

SA

LOUNGERL. 63.5

KITCHENRL. 63.5

BATHROOMRL. 63.5

BEDROOM 2RL. 63.5

BEDROOM 3RL. 63.5

SITTINGRL. 63.5

BALCONYRL. 61.6

179° 59' 00"

359° 59' 00"

98°

38'

0

0"

67.055 MHW

12.1

9

70.105 MHWM.

H.

W.

M.

SA

SA

90 6,000 90

1,44

090

8,93

390

1,50

0

3,420 90 1,300

280

2,70

090

4,42

0

280 2,470 90 2,250

2,51

090

1,00

090

3,56

0

3,300 2,100 600

760

2,50

02,

413

2,50

076

0

90 6,000 90

3,300 2,100 600

1,15

090

1,46

090

1,600 870

420

700

940

130

820

1,65

090

230

908,

933

90

3,21

72,

500

3,21

7

BATHROOMRL. 63.5

BEDROOM 2RL. 63.5

BEDROOM 3RL. 63.5

SITTINGRL. 63.5

BALCONYRL. 61.6 LOFT

RL. 5.6

W/RRL. 63.5

W/RRL. 63.5

ENSUITERL. 63.5

MASTER SUITERL. 63.5

seat

4. Existing First Floor Layout1:100

5. First Floor Demolition Layout1:100

3 First Floor Layout1:100

Page 4: 25 Mirral Road, CARINGBAH SOUTH

RevID ChID Change Name DatePlot Date:Drawn

139 Prices CircuitWORONORA

139 Prices Circuit, WoronoraPROJECT NAME :

DRAWING TITLE :

Site:

Project NO.

DRAWING NO.

A104

REVISION NO.

Issue A - rev 2Development Application

NOTEThe Builder shall check all dimensions and levels on site prior to construction.Notify any errors, discrepancies or omissions to the architect. Refer to writtendimensions only. Do not scale drawings. Drawings shall not be used forconstruction purposes until issued for construction. This drawing reflects a designby Creative Home Designs and is to be used only for work when authorised inwriting by Creative Home Designs.

All boundaries and contours are subject to survey drawing W-01. All levels toAustralian Height Data. It is the contractors responsibility to confirm allmeasurements on site and locations of any services prior to work on site.

All documents here within are subject to Australian Copyright Laws.

Project PartnersRefer to consultant documentation when directed- BCA Consultant - TBC- Civil Engineer - TBC- Hydraulic Engineer - TBC- Landscape Designer - TBC- Mechanical Engineer - TBC- Structural Engineer - TBC- Surveyor - TBC

2/10/20CHD101

Project Status

CH

Michele DoddClient

PLANS

E-01

2,54

02,

450

180

2,52

02,

400

1,28

7

771

6,36

3

3,64

2Timber framed deck & Stairs,tile finish to owners selection

Timber framed deck with tile finish toowners selection. Concrete stairs with offform finish to owners selection

140 x 140 hardwood posts

Timber framed parapet with 10 klip lock roof behindconnected into box gutter and into existing stormwater

90 x 90 hardwood posts

Timber framed roof at 100

pitch, colorbond custom orbsheeting with metal fascia +

gutter to match

Aluminium framed windows in accordance with BASIX

90mm timber frame, cladding to owners selection

Timber framed roof at 100 pitch, colorbond custom orbsheeting with metal fascia + gutter to match

Timber framed roof at 100 pitch, colorbond customorb sheeting with metal fascia + gutter to match

Ground Floor Line RL. 3.81

First Floor Line RL. 6.35

Ceiling Line RL. 8.8

Garage Floor Line RL. 2.72

Studio Floor Line RL. 2.9

Loft Floor Line RL. 5.42

Top Plate Line RL. 5.42

Top of Roof Line RL. 5.42

2,54

02,

450

180

2,52

02,

400

1,28

7

Timber framed deck & Stairs,tile finish to owners selection

Timber framed deck with tile finish toowners selection. Concrete stairs with off

form finish to owners selection

140 x 140 hardwood posts

Timber framed parapet with 10 klip lock roof behindconnected into box gutter and into existing stormwater

90 x 90 hardwood posts

Timber framed roof at 100

pitch, colorbond custom orbsheeting with metal fascia +gutter to match

Aluminium framed windows in accordance with BASIX

90mm timber frame, cladding to owners selection

Timber framed roof at 100 pitch, colorbond custom orbsheeting with metal fascia + gutter to match

Timber framed roof at 100 pitch, colorbond customorb sheeting with metal fascia + gutter to match

270mm double cavity brick with cement render & paint finish

Ground Floor Line RL. 3.81

First Floor Line RL. 6.35

Ceiling Line RL. 8.8

Garage Floor Line RL. 2.72

Studio Floor Line RL. 2.9

Loft Floor Line RL. 5.42

Top Plate Line RL. 5.42

Top of Roof Line RL. 5.42

2,54

02,

450

Timber framed deck with tile finish toowners selection. Concrete stairs with off

form finish to owners selection

140 x 140 hardwood posts

Timber framed parapet with 10 klip lock roof behindconnected into box gutter and into existing stormwater

Aluminium framed doors in accordance with BASIX

Aluminium framed entry door in accordance with BASIX

Ground Floor Line RL. 3.81

First Floor Line RL. 6.35

Ceiling Line RL. 8.8

2,54

02,

450

Timber framed deck & Stairs, tilefinish to owners selection

Aluminium framed doors inaccordance with BASIX

Ground Floor Line RL. 3.81

First Floor Line RL. 6.35

Ceiling Line RL. 8.8

1 East Elevation1:100

2 West Elevation1:100

3 North (dwelling) Elevation1:100

4 South (dwelling) Elevation1:100

Page 5: 25 Mirral Road, CARINGBAH SOUTH

RevID ChID Change Name DatePlot Date:Drawn

139 Prices CircuitWORONORA

139 Prices Circuit, WoronoraPROJECT NAME :

DRAWING TITLE :

Site:

Project NO.

DRAWING NO.

A105

REVISION NO.

Issue A - rev 2Development Application

NOTEThe Builder shall check all dimensions and levels on site prior to construction.Notify any errors, discrepancies or omissions to the architect. Refer to writtendimensions only. Do not scale drawings. Drawings shall not be used forconstruction purposes until issued for construction. This drawing reflects a designby Creative Home Designs and is to be used only for work when authorised inwriting by Creative Home Designs.

All boundaries and contours are subject to survey drawing W-01. All levels toAustralian Height Data. It is the contractors responsibility to confirm allmeasurements on site and locations of any services prior to work on site.

All documents here within are subject to Australian Copyright Laws.

Project PartnersRefer to consultant documentation when directed- BCA Consultant - TBC- Civil Engineer - TBC- Hydraulic Engineer - TBC- Landscape Designer - TBC- Mechanical Engineer - TBC- Structural Engineer - TBC- Surveyor - TBC

2/10/20CHD101

Project Status

CH

Michele DoddClient

PLANS

E-02

2,54

02,

450

180

2,52

02,

400

1,28

7

1,00

0

1,20

0

811

Timber framed deck & Stairs, hardwooddecking boards to owners selection Timber framed deck & Stairs, hardwood

decking boards to owners selection

140 x 140 hardwood posts

Timber framed parapet with 10 klip lock roof behindconnected into box gutter and into existing stormwater

90 x 90 hardwood posts

Timber framed roof at 100

pitch, colorbond custom orbsheeting with metal fascia +

gutter to match

Concrete slab to engineers detail

1.0m high balustrade

Timber framed roof at 100 pitch, colorbond custom orbsheeting with metal fascia + gutter to match

Timber framed roof at 100 pitch, colorbond customorb sheeting with metal fascia + gutter to match

Aluminium framed floor to engineers detail

Open ceiling joists for extra storage

Ground Floor Line RL. 3.81

First Floor Line RL. 6.35

Ceiling Line RL. 8.8

Garage Floor Line RL. 2.72

Studio Floor Line RL. 2.9

Loft Floor Line RL. 5.42

Top Plate Line RL. 5.42

Top of Roof Line RL. 5.42

STORAGE

STORAGE

LOFT

STUDIO

PORCHENTRYW.CBARDINING

ENS. W/R BATHROOM SITTING

DECK

BALCONY

1,15

01,

050

700

2,10

0

2,100

1,20

090

0

600

1,60

050

0

2,500

1,15

01,

050

940

1,60

050

0

2,100

1,60

050

0

2,500

1,60

050

0

2,100

2,10

0

6,000

2,10

0

1,500

2,10

0

2,400

2,10

0

2,400

1,60

050

0

2,500

Floor Line

W1 (south)Sliding Window1050 x 700Standard AluminiumSingle Clear(or U-Value: 7.63, SHGC: 0.75)Quantity 1

Floor Line

D1 (north)Sliding Door2100 x 2100Standard AluminiumSingle Clear(or U-Value: 7.63, SHGC: 0.75)Quantity 1

NOTE:THIS SCHEDULE IS PROVIDED FORPRICING PURPOSES ONLY. CHECKALL DIMENSIONS ON SITE

W2 (south)Sliding Window1050 x 940Standard AluminiumSingle Clear(or U-Value: 7.63, SHGC: 0.75)Quantity 1

W3 (east)Awning Window900 x 600Standard AluminiumSingle Clear(or U-Value: 7.63, SHGC: 0.75)Quantity 2

W4 (east)Sliding Window500 x 2500Standard AluminiumSingle Clear(or U-Value: 7.63, SHGC: 0.75)Quantity 1

WINDOW SCHEDULE:

W5 (west)Sliding Window500 x 2100Standard AluminiumSingle Clear(or U-Value: 7.63, SHGC: 0.75)Quantity 1

W6 (north)Sliding Window500 x 2500Standard AluminiumSingle Clear(or U-Value: 7.63, SHGC: 0.75)Quantity 2

W7 (east)Sliding Window500 x 2100Standard AluminiumSingle Clear(or U-Value: 7.63, SHGC: 0.75)Quantity 1

D3 (south)Stacker Door2100 x 6000Standard AluminiumSingle Clear(or U-Value: 7.63, SHGC: 0.75)Quantity 1

D2 (north)Entry Door2100 x 1500Standard AluminiumSingle Clear(or U-Value: 7.63, SHGC: 0.75)Quantity 1

D4 (south)Sliding Door2100 x 2400Standard AluminiumSingle Clear(or U-Value: 7.63, SHGC: 0.75)Quantity 1

D5 (south)Sliding Door2100 x 2400Standard AluminiumSingle Clear(or U-Value: 7.63, SHGC: 0.75)Quantity 1

W8 (south)Sliding Window500 x 2500Standard AluminiumSingle Clear(or U-Value: 7.63, SHGC: 0.75)Quantity 1

180

2,52

02,

400

1,28

7

Timber framed roof at 100 pitch, colorbond customorb sheeting with metal fascia + gutter to match

90mm timber frame, cladding to owners selection

90mm timber frame, cladding to owners selection

Aluminium framed windows in accordance with BASIX

Timber framed roof at 100 pitch, colorbond customorb sheeting with metal fascia + gutter to match

5.0m x 2.1m panel lift garage door

Garage Floor Line RL. 2.72

Studio Floor Line RL. 2.9

Loft Floor Line RL. 5.42

Top Plate Line RL. 5.42

Top of Roof Line RL. 5.42

180

2,52

02,

400

1,28

7

90 x 90 hardwood posts

Timber framed roof at 100 pitch,colorbond custom orb sheeting with metalfascia + gutter to match

Aluminium framed doors in accordance with BASIX90mm timber frame, cladding to owners selection

Timber framed roof at 100 pitch, colorbond custom orbsheeting with metal fascia + gutter to match

2.5m x 2.1m panel lift garage door

Garage Floor Line RL. 2.72

Studio Floor Line RL. 2.9

Loft Floor Line RL. 5.42

Top Plate Line RL. 5.42

Top of Roof Line RL. 5.42

Building Sustainability Index www.basix.nsw.gov.au

Alterations and AdditionsCertificate number: A391167

This certificate confirms that the proposed development will meet the NSWgovernment's requirements for sustainability, if it is built in accordance with thecommitments set out below. Terms used in this certificate, or in the commitments,have the meaning given by the document entitled "BASIX Alterations and AdditionsDefinitions" dated 06/10/2017 published by the Department. This document isavailable at www.basix.nsw.gov.au

SecretaryDate of issue: Friday, 02, October 2020To be valid, this certificate must be lodged within 3 months of the date of issue.

Project address

Project name 139 Prices CircuitStreet address 139 Prices Circuit Woronora 2232Local Government Area Sutherland Shire CouncilPlan type and number Deposited Plan 11327Lot number 10Section number

Project type

Dwelling type Separate dwelling house

Type of alteration andaddition

My renovation work is valued at $50,000 or more,and does not include a pool (and/or spa).

Certificate Prepared by (please complete before submitting to Council or PCA)

Name / Company Name: Cameron Hooper

ABN (if applicable): N/A

page 1 / 5

Fixtures and systems Show onDA Plans

Show onCC/CDCPlans &specs

CertifierCheck

Hot waterThe applicant must install the following hot water system in the development: electric heat pump system that is eligible to create RenewableEnergy Certificates under the (Commonwealth) Renewable Energy (Electricity) Regulations 2001 (incorporating Amendment Regulations2005 (No. 2)).

LightingThe applicant must ensure a minimum of 40% of new or altered light fixtures are fitted with fluorescent, compact fluorescent, orlight-emitting-diode (LED) lamps.

FixturesThe applicant must ensure new or altered showerheads have a flow rate no greater than 9 litres per minute or a 3 star water rating.

The applicant must ensure new or altered toilets have a flow rate no greater than 4 litres per average flush or a minimum 3 star water rating.

The applicant must ensure new or altered taps have a flow rate no greater than 9 litres per minute or minimum 3 star water rating.

BASIX Certificate number: A391167 page 2 / 5

Planning, Industry & Environment Building Sustainability Index www.basix.nsw.gov.au

Construction Show onDA Plans

Show onCC/CDCPlans &specs

CertifierCheck

Insulation requirementsThe applicant must construct the new or altered construction (floor(s), walls, and ceilings/roofs) in accordance with the specifications listed inthe table below, except that a) additional insulation is not required where the area of new construction is less than 2m2, b) insulation specifiedis not required for parts of altered construction where insulation already exists.

Construction Additional insulation required (R-value) Other specifications

suspended floor with enclosed subfloor:framed (R0.7).

R0.60 (down) (or R1.30 includingconstruction)

BASIX Certificate number: A391167 page 3 / 5

Planning, Industry & Environment Building Sustainability Index www.basix.nsw.gov.au

Glazing requirements Show onDA Plans

Show onCC/CDCPlans &specs

CertifierCheck

Windows and glazed doorsThe applicant must install the windows, glazed doors and shading devices, in accordance with the specifications listed in the table below.Relevant overshadowing specifications must be satisfied for each window and glazed door.

The following requirements must also be satisfied in relation to each window and glazed door:

Each window or glazed door with standard aluminium or timber frames and single clear or toned glass may either match the description, or,have a U-value and a Solar Heat Gain Coefficient (SHGC) no greater than that listed in the table below. Total system U-values and SHGCsmust be calculated in accordance with National Fenestration Rating Council (NFRC) conditions.

For projections described as a ratio, the ratio of the projection from the wall to the height above the window or glazed door sill must be atleast that shown in the table below.

Windows and glazed doors glazing requirementsWindow / doorno.

Orientation Area ofglassinc.frame(m2)

Overshadowing Shading device Frame and glass typeHeight(m)

Distance(m)

W1 S 0.735 0 0 projection/height above sill ratio>=0.43

standard aluminium, single clear, (orU-value: 7.63, SHGC: 0.75)

W2 SE 0.98 0 0 projection/height above sill ratio>=0.43

standard aluminium, single clear, (orU-value: 7.63, SHGC: 0.75)

D1 N 4.41 0 0 projection/height above sill ratio>=0.43

standard aluminium, single clear, (orU-value: 7.63, SHGC: 0.75)

D2 N 1.1 0 0 projection/height above sill ratio>=0.43

standard aluminium, single clear, (orU-value: 7.63, SHGC: 0.75)

D3 S 12.6 0 0 projection/height above sill ratio>=0.43

standard aluminium, single clear, (orU-value: 7.63, SHGC: 0.75)

D4 S 5 0 0 projection/height above sill ratio>=0.43

standard aluminium, single clear, (orU-value: 7.63, SHGC: 0.75)

BASIX Certificate number: A391167 page 4 / 5

Planning, Industry & Environment Building Sustainability Index www.basix.nsw.gov.au

1 Section A- A1:100

2 Window Schedule

3 North (studio) Elevation1:100

4 South (studio) Elevation1:100

Page 6: 25 Mirral Road, CARINGBAH SOUTH

RevID ChID Change Name DatePlot Date:Drawn

139 Prices CircuitWORONORA

139 Prices Circuit, WoronoraPROJECT NAME :

DRAWING TITLE :

Site:

Project NO.

DRAWING NO.

A106

REVISION NO.

Issue A - rev 2Development Application

NOTEThe Builder shall check all dimensions and levels on site prior to construction.Notify any errors, discrepancies or omissions to the architect. Refer to writtendimensions only. Do not scale drawings. Drawings shall not be used forconstruction purposes until issued for construction. This drawing reflects a designby Creative Home Designs and is to be used only for work when authorised inwriting by Creative Home Designs.

All boundaries and contours are subject to survey drawing W-01. All levels toAustralian Height Data. It is the contractors responsibility to confirm allmeasurements on site and locations of any services prior to work on site.

All documents here within are subject to Australian Copyright Laws.

Project PartnersRefer to consultant documentation when directed- BCA Consultant - TBC- Civil Engineer - TBC- Hydraulic Engineer - TBC- Landscape Designer - TBC- Mechanical Engineer - TBC- Structural Engineer - TBC- Surveyor - TBC

2/10/20CHD101

Project Status

CH

Michele DoddClient

PLANS

Perspectives

1 Generic Perspective (7)

2 Generic Perspective (8)

3 Generic Perspective (9)