TRAFFIC NODE 20P
•TRAFFIC NODE CONSISTS FROM 20 slots + 1
•20 Slots can filled by MMU cards or NPU car
LTU cards from slot 2 to slot 21 .
•Power cables inserted to Slot 0 & Slot 1 .
•Fan above link to cooling link with 2 power
sources.
8/20/2019 235766365 Ericsson Link Presentation
3/68
TRAFFIC NODE 20P
Power cables on slot 0 & slot 1
8/20/2019 235766365 Ericsson Link Presentation
4/68
TRAFFIC NODE 20P
NPU card whic
control on TN
8/20/2019 235766365 Ericsson Link Presentation
5/68
TRAFFIC NODE 20P
MMU cards that
present link indoorcard
8/20/2019 235766365 Ericsson Link Presentation
6/68
TRAFFIC NODE 20P
IF cables connect
RAU with MMU
8/20/2019 235766365 Ericsson Link Presentation
7/68
TRAFFIC NODE 20P
XPIC cables connect
between Vertical &
Horizontal MMU
8/20/2019 235766365 Ericsson Link Presentation
8/68
TRAFFIC NODE 20P
Fan with two power source for
cooling TN
8/20/2019 235766365 Ericsson Link Presentation
9/68
Introduction to E/// link
E/// links divided into three types
1-TRAFFIC NODE 20P
•-used at nodal sites with huge traffic
•- have 20 slots + 1 slot for power .•-have 2 power sources .
•-have fan with 2 power sources .
•-compatible with Fiber STM .
8/20/2019 235766365 Ericsson Link Presentation
10/68
Introduction to E/// link
2-TRAFFIC NODE 6P-used at nodal sites with medium traffic .
-have 6 slots + 1slot for power .
-have 2 power sources .
-have fan with 2 power sources .
8/20/2019 235766365 Ericsson Link Presentation
11/68
Introduction to E/// link
3-COMPACT NODE-used at end point sites with low traffic .
-consists from 1 indoor card only .
-have 2 power sources .
-maximum number of E1=16E1 .
8/20/2019 235766365 Ericsson Link Presentation
12/68
Types of protection
• Protection divided in three types
1- Protection (2+2)
- Used frequency as Vertical & Horizontal to duplicate the traffic
- Used 4 MMU cards .
- Used 4 RAU outdoor .
- Used XPIC cable to connect between Vertical & Horizontal MM
- Used waveguide cable to connect between Vertical & Horizont
RAU .
- Used for huge traffic .
8/20/2019 235766365 Ericsson Link Presentation
13/68
Types of protection
2-Protection (1+1)
-used all frequency to transfer the traffic .
-used 2 MMU cards .
-used 2 RAU outdoor .
-less interference than (2+2) protection .
8/20/2019 235766365 Ericsson Link Presentation
14/68
Types of protection
3-Protection (1+0)-used all frequency to transfer the traffic .
-used 1 MMU card .
-used 1 RAU outdoor .
-less secure than (1+1) protection
8/20/2019 235766365 Ericsson Link Presentation
15/68
HOW TO ACESS TO
E/// LINK (20P)
8/20/2019 235766365 Ericsson Link Presentation
16/68
HOW TO ACCESS TO E/// LINK
ACCESS from TR-7
LAN port by Ethernet
cable
8/20/2019 235766365 Ericsson Link Presentation
17/68
HOW TO ACCESS TO E/// LINK
PC IP (LINK IP+1
SUBNET MASK AS Show
LINK IP As Sho
8/20/2019 235766365 Ericsson Link Presentation
18/68
HOW TO ACCESS TO E/// LINK
ACCESS TO MINI-LINK CRAFT
program
8/20/2019 235766365 Ericsson Link Presentation
19/68
HOW TO ACCESS TO E/// LINK
Insert link IP as shown
Username=control_user
Password=ericsson
HOW TO ACESS TO
8/20/2019 235766365 Ericsson Link Presentation
20/68
HOW TO ACESS TO
E/// LINK (20P)
From O&M port
by using
USB-MINI cable
8/20/2019 235766365 Ericsson Link Presentation
21/68
HOW TO ACESS TO
E/// LINK (20P)
IP=10.0.0.1
User= control_use
Password= ericsso
8/20/2019 235766365 Ericsson Link Presentation
22/68
How to upload configuration file to PC
From tools ftp server in new window
Press start
Before take any action in TN must save this file
8/20/2019 235766365 Ericsson Link Presentation
23/68
How to upload configuration file to PC
From TN configure
load configuration
8/20/2019 235766365 Ericsson Link Presentation
24/68
How to upload configuration file to PC
Upload to ftp server
User name= defualt
Password= defualt
Choose local server
Insert PC IP (10.0.0.2 in case of use
mini USB cable )
Press Apply
8/20/2019 235766365 Ericsson Link Presentation
25/68
How to upload configuration file to PC
Press update progres
several times
8/20/2019 235766365 Ericsson Link Presentation
26/68
How to upload configuration file to PC
File saved in
c:\tn_ftp_home\tn_backup
_configuration
8/20/2019 235766365 Ericsson Link Presentation
27/68
HOW to Restart TN
From TN tools restart
8/20/2019 235766365 Ericsson Link Presentation
28/68
HOW to Restart TN
Warm restart =restart
TN without down thetraffic
Cold restart =restart
TN with down the
traffic
8/20/2019 235766365 Ericsson Link Presentation
29/68
How to detect SN & product number for any card for TN
From TN tools inventory
8/20/2019 235766365 Ericsson Link Presentation
30/68
How to detect SN & product number for any card for TN
8/20/2019 235766365 Ericsson Link Presentation
31/68
HOW TO Gets LPM FOR link
Open MMU2 H
open RAU IF
from switch
Choose performan
8/20/2019 235766365 Ericsson Link Presentation
32/68
HOW TO GETS LPM FOR TN
PRESS More than 15
minute intervals
8/20/2019 235766365 Ericsson Link Presentation
33/68
HOW TO GETS LPM FOR TN
Press (CTRL+A) then(CTRL+C) to copy
8/20/2019 235766365 Ericsson Link Presentation
34/68
HOW TO GETS LPM FOR TN
Open new Excel sheet &
press (CTRL+V) to paste
8/20/2019 235766365 Ericsson Link Presentation
35/68
HOW TO GETS LPM FOR TN
After we paste Values then
press save to save the file
8/20/2019 235766365 Ericsson Link Presentation
36/68
HOW TO GETS NOTIFICATION HISTORY
From TN View
Notification Histor
8/20/2019 235766365 Ericsson Link Presentation
37/68
HOW TO GETS NOTIFICATION HISTORY
8/20/2019 235766365 Ericsson Link Presentation
38/68
HOW TO GETS NOTIFICATION HISTORY
Press (CTRL+A) then press (CTRL+C)
to copy
8/20/2019 235766365 Ericsson Link Presentation
39/68
HOW TO GETS NOTIFICATION HISTORY
Open new EXCEL Sheet
press (CTRL+V) to paste
8/20/2019 235766365 Ericsson Link Presentation
40/68
HOW TO GETS NOTIFICATION HISTORY
Press Save to save the file
8/20/2019 235766365 Ericsson Link Presentation
41/68
HOW to restart MMU
From MMU right clickTools Restart
8/20/2019 235766365 Ericsson Link Presentation
42/68
HOW to restart MMU
Press Cold Restart
8/20/2019 235766365 Ericsson Link Presentation
43/68
How to gets link RX & TX frequency
From Radio links choose slot configure
Radio link
8/20/2019 235766365 Ericsson Link Presentation
44/68
How to gets link RX & TX frequency & Modulation
8/20/2019 235766365 Ericsson Link Presentation
45/68
How to gets link RX & TX frequency & Modulation
HOW TO GETS TX & RX l l
8/20/2019 235766365 Ericsson Link Presentation
46/68
HOW TO GETS TX & RX level
Press left click on
MMU that present
link
HOW TO GETS TX & RX l l
8/20/2019 235766365 Ericsson Link Presentation
47/68
HOW TO GETS TX & RX level
Gets TX & RX
value
HOW TO MAKE LOOPS
8/20/2019 235766365 Ericsson Link Presentation
48/68
HOW TO MAKE LOOPS
Press on loops
HOW TO MAKE LOOPS
8/20/2019 235766365 Ericsson Link Presentation
49/68
HOW TO MAKE LOOPS
HOW TO MAKE LOOPS
8/20/2019 235766365 Ericsson Link Presentation
50/68
HOW TO MAKE LOOPS
Press on RF icon to
make loop on RAU to
check both
(RAU+IF+MMU)
HOW TO MAKE LOOPS
8/20/2019 235766365 Ericsson Link Presentation
51/68
HOW TO MAKE LOOPS
Press Save to confirmloop
HOW TO MAKE LOOPS
8/20/2019 235766365 Ericsson Link Presentation
52/68
HOW TO MAKE LOOPS
Alarms should cleared on(MMU+IF+RAU) except
(HCC alarm)
How to change MMU
8/20/2019 235766365 Ericsson Link Presentation
53/68
How to change MMU
Press on BR button
How to change MMU
8/20/2019 235766365 Ericsson Link Presentation
54/68
How to change MMU
BR orange LED shbe lights up
How to change MMU
8/20/2019 235766365 Ericsson Link Presentation
55/68
How to change MMU
Upper and lower
Screw should be
detach
How to change MMU
8/20/2019 235766365 Ericsson Link Presentation
56/68
How to change MMU
Upper and lower
clasps should beraises
How to change MMU
8/20/2019 235766365 Ericsson Link Presentation
57/68
g
Release IF cable &XPIC cable
How to change MMU
8/20/2019 235766365 Ericsson Link Presentation
58/68
g
Remove MMU card &
insert new MMU card
and connect IF cable &
XPIC cable
Kinds of alarms at TN
8/20/2019 235766365 Ericsson Link Presentation
59/68
Critical alarm
Major alarm
Minor alarm
Warning alarm
Intermediate alarm
How to switch between 2 MMU
8/20/2019 235766365 Ericsson Link Presentation
60/68
Press on switch mode
How to switch between 2 MMU
8/20/2019 235766365 Ericsson Link Presentation
61/68
Change switch mode from
Automatic manual
How to switch between 2 MMU
8/20/2019 235766365 Ericsson Link Presentation
62/68
After select manual mode
press Save
How to switch between 2 MMU
8/20/2019 235766365 Ericsson Link Presentation
63/68
Choose Active MMU fro
MMU1 to MMU2
How to switch between 2 MMU
8/20/2019 235766365 Ericsson Link Presentation
64/68
After change to MMU2
press Save
How to switch between 2 MMU
8/20/2019 235766365 Ericsson Link Presentation
65/68
From switch mode
change from Manual
to Automatic
How to switch between 2 MMU
8/20/2019 235766365 Ericsson Link Presentation
66/68
Then press Save to savechanges and now we
switch between 2 MMU
How to check interference between vertical & Horizontal MM
8/20/2019 235766365 Ericsson Link Presentation
67/68
How to check interference between vertical & Horizontal MM
•If RX level for Vertical MMU on link = 30 db .
•We disconnect Vertical MMU from other side
•Check RX level for Vertical MMU on link 60 db there are interference betwVertical &Horizontal .
How to check interference between different links
8/20/2019 235766365 Ericsson Link Presentation
68/68
How to check interference between different links
•Disconnect both Vertical & Horizontal MM
•Check RX level on other side .
•RX level should less than 95 db .
•If RX level more than 95 db there areinterference from another link .