24
23-3/4" LENGTH 23-3/4" WIDTH Step 2 Step 1 15 16 " T-GRID Step 1 Step 2 Step 3 Step 2 Step 1 15 16 " T-GRID 15 16 " T-GRID 1 2 " 15 16 " T-GRID BEND DOWN TAB for cut panel terminations, two per side CUT GLADIUS PANEL 15 16 " T-GRID GLADIUS BEND-DOWN TAB Two per side, opposite cut edge. 1 2 " LX02 TC2 CLIP To attach field cut T-grid to trim. Step 3 Step 1 Step 2 1 4 " CUT GLADIUS PANEL 15 16 " T-GRID 15 16 " T-GRID GLADIUS BEND- DOWN TAB Two per side, opposite cut edge. 1 2 " 1 2 " FROM FACE OF T-GRID TO FACE OF GLADIUS PANEL BOX MOLD BOX MOLD HOLD DOWN CLIP (11" long) Install 2 each per cut panel. ANGLE BRACKET (not by Hunter Douglas) To attach field cut T-grid to wall. PRIOR TO INSTALLING PANEL, ROTATE THE TWO SAFETY WIRES 90° TO LOCK POSITION. 4" 6" 2 1 8 " Brace with strap. 4'-0" on center, maximum not by Hunter Douglas GL02 GL04 GL06 1/2" 1/2" 1/2" 1 2 " FROM FACE OF T-GRID TO FACE OF GLADIUS PANEL 1 2 " FROM FACE OF T-GRID TO FACE OF GLADIUS PANEL, Typical. FULL GLADIUS PANEL Typical TRIM CLIP TRIM CLIP 15 16 " T-GRID SYSTEM INSTALLED ON 24" x 24" MODULE BACK OF PANEL DETAIL SCALE: NOT TO SCALE BACK OF PANEL DETAIL SCALE: NOT TO SCALE STANDARD TERMINATION - BOX MOLD DETAIL SCALE: NOT TO SCALE 1 4 " PANEL INSTALLATION DETAIL SCALE: NOT TO SCALE PANEL REMOVAL DETAIL SCALE: NOT TO SCALE FLOATING TRIM TERMINATION - CUT PANELS DETAIL SCALE: NOT TO SCALE GLADIUS FLOATING TRIM TERMINATION - FULL PANELS ONLY DETAIL SCALE: NOT TO SCALE 1 4 " 1 4 " 1 4 " 5015 Oakbrook Parkway, Suite 100 Norcross, GA 30093 O 800.366.4327 F 770.806.0214 CTSpecialtyCeilings.com All rights reserved. This drawing is the property of CertainTeed Ceilings Corporation. It may not be copied or multiplied, neither wholly nor partly. It may not be submitted for perusal to third parties. SPECIFICATIONS (unless noted otherwise) MATERIAL: .032" ALUMINUM FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH PERFORATION: CONTACT HUNTER DOUGLAS GLADIUS INSTALLATION DETAILS PROJECT: GLADIUS PRODUCT SPECIFICATIONS DRAWING NUMBER: GLADIUS-A1.0 SCALE: AS SHOWN DRAWN BY: HD ENGINEERING DATE: 3/6/19

23-3/4 WIDTH 23-3/4 LENGTH - CertainTeed · 3/6/2019  · 23-3/4" WIDTH 23-3/4" LENGTH Step 2 Step 1 15 16" T-GRID Step 1 Step 2 Step 3 Step 2 Step 1 15 16" T-GRID 15 16" T-GRID 1

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • 23-3/4

    " LENG

    TH23-3/4" WIDTH

    Step 2

    Step 1

    1516" T-GRID

    Step 1

    Step 2

    Step 3

    Step 2Step 1

    1516" T-GRID

    1516" T-GRID

    1 2"

    1516" T-GRID

    BEND DOWN TABfor cut panelterminations,two per side

    CUT GLADIUS PANEL

    1516" T-GRID

    GLADIUS BEND-DOWN TABTwo per side, opposite cut edge.

    1 2"

    LX02

    TC2 CLIP To attach field cut

    T-grid to trim.

    Step 3

    Step 1

    Step 2

    14" CUT GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    GLADIUS BEND-DOWN TAB

    Two per side,opposite cut edge.

    1 2"

    12" FROM FACE OF

    T-GRID TO FACE OFGLADIUS PANEL

    BOX MOLD

    BOX MOLD HOLD DOWN CLIP(11" long) Install 2 each per cut panel.

    ANGLE BRACKET(not by Hunter Douglas)

    To attach field cut T-grid to wall.

    PRIOR TO INSTALLING PANEL, ROTATE THETWO SAFETY WIRES 90° TO LOCK POSITION.

    4"

    6"

    21 8"

    Brace with strap.4'-0" on center, maximum

    not by Hunter Douglas

    GL02 GL04 GL06

    1/2"

    1/2"

    1/2"

    12" FROM FACE OF

    T-GRID TO FACE OFGLADIUS PANEL 12" FROM FACE OF

    T-GRID TO FACE OFGLADIUS PANEL, Typical.

    FULLGLADIUS

    PANELTypical

    TRIM CLIP TRIM CLIP

    1516" T-GRID SYSTEM INSTALLED

    ON 24" x 24" MODULE

    BACK OF PANEL DETAILSCALE: NOT TO SCALE

    BACK OF PANEL DETAILSCALE: NOT TO SCALE

    STANDARD TERMINATION - BOX MOLD DETAILSCALE: NOT TO SCALE

    14"

    PANEL INSTALLATION DETAILSCALE: NOT TO SCALE

    PANEL REMOVAL DETAILSCALE: NOT TO SCALE

    FLOATING TRIM TERMINATION - CUT PANELS DETAILSCALE: NOT TO SCALE

    GLADIUS FLOATING TRIM TERMINATION - FULL PANELS ONLY DETAILSCALE: NOT TO SCALE

    14"

    14"

    14"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All r ights reserved. This

    drawing is the proper ty

    of CertainTeed Ceilings

    Corporation. It may not

    be copied or mult ipl ied,

    n e i t h e r w h o l l y n o r

    par t l y . I t may not be

    submitted f or perusal to

    t h i r d p a r t i e s .

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER DOUGLAS

    GLADIUS INSTALLATION DETAILS

    PROJECT: GLADIUS PRODUCT SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.0

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

  • 23-3/4

    " LENG

    TH23-3/4" WIDTH

    'B''A'

    3 4"3 8"

    11 8"

    1132"3 4"

    3 8"

    11 8"

    2334" PANEL FACE 2334" PANEL FACE

    1932"

    BACK OF PANEL DETAILSCALE: NOT TO SCALE

    SECTION 'A' DETAILSCALE: NOT TO SCALE

    SECTION 'B' DETAILSCALE: NOT TO SCALE

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS PANEL - 24" X 24"

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.1

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • Step 2

    Step 1

    STEP 2STEP 1

    1516" T-GRID

    1516" T-GRID

    1/2"

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    PANEL & GRID - BACK OF SYSTEM DETAILSCALE: NOT TO SCALE

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS PANEL INSTALLATION

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.2

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • 1516" T-GRID

    STEP 1

    STEP 2

    STEP 3

    1516" T-GRID

    Step 3

    Step 1

    Step 2

    PANEL & GRID - BACK OF SYSTEM DETAILSCALE: NOT TO SCALE

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS PANEL REMOVAL

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.3

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • GLADIUS PANEL

    1516" T-GRID

    GLADIUS SAFETY CLIP

    14"

    REVEAL

    GLADIUS PANEL ISOMETRIC VIEWSCALE: NOT TO SCALE

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    OVERALL ISOMETRIC VIEW

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.4

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • 1516" T-GRID 1516" T-GRID

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    2' x 2' LAY-IN LIGHTINDEPENDENTLY SUPPORTEDnot by Hunter Douglas

    GLADIUS PANEL

    1516" T-GRID 1516" T-GRID

    GLADIUS PANEL

    2'-0"

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    ℄ T-GRID ℄ T-GRID

    2' x 2' LAY-IN LIGHTINDEPENDENTLY SUPPORTEDnot by Hunter Douglas

    2'-0"

    ℄ T GRID ℄ T GRID

    24" X 24" LAY-IN LIGHT DETAILSCALE: 1-1/2" = 1'-0"

    24" X 24" LAY-IN LIGHT DETAILSCALE: 1-1/2" = 1'-0"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    24" X 24" LAY-IN LIGHT

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.5

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • 23-3/4

    " LENG

    TH23-3/4" WIDTH

    1516" T-GRID

    1/2"

    'A'

    DOWN LIGHTMust be independentlysupported in accordancewith local building code.not by Hunter Douglas

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    PANEL WITH ROUND FIXTURE CUT-OUT DETAILSCALE: NOT TO SCALE

    SECTION 'A' DETAILSCALE: 3" = 1'-0"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS PANEL WITH DOWN

    LIGHT

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.6

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • 1178" 1178"

    117 8"

    117 8"

    ℄ SPECIFY DIAMETER _____

    ROUND FIXTURE CUT-OUT DETAILSCALE: 1-1/2" = 1'-0"

    RECESSED DOWN LIGHT DETAILSCALE: 1-1/2" = 1'-0"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS PANEL WITH DOWN

    LIGHT

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.7

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • 23-3/4

    " LENG

    TH23-3/4" WIDTH

    1516" T-GRID

    1/2"

    'A'

    SPRINKLERMust be independentlysupported in accordancewith local building code.not by Hunter Douglas

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    PANEL WITH ROUND SPRINKLER CUT-OUT DETAILSCALE: NOT TO SCALE

    SECTION 'A' DETAILSCALE: 3" = 1'-0"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS PANEL WITH SPRINKLER

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.8

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • 14"

    CUT GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    GLADIUS BEND-DOWN TAB

    Two per side,opposite cut edge.

    1/2"

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    1"14"

    BOX MOLD

    BOX MOLD HOLD DOWN CLIP(11" long)

    Install 2 each per cut panel.

    ANGLE BRACKET(not by Hunter Douglas)

    To attach field cut T-grid to wall.

    CUT GLADIUS PANELBOX MOLD

    BOX MOLD HOLD DOWN CLIP(11" long) Install 2 each per cut panel.

    ANGLE BRACKET(not by Hunter Douglas)

    To attach field cut T-grid to wall.

    1516" T-GRID

    1516" T-GRID

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    1/2"

    TYPICAL PERIMETER SECTION - CUT PANEL AT BOX MOLD DETAILSCALE: 3" = 1'-0"

    TYPICAL PERIMETER SECTION - CUT PANEL AT BOX MOLD DETAILSCALE: 3" = 1'-0"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS FIELD CUT PERIMETER

    DETAIL WITH BOX MOLD TRIM

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.9

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • CUT GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    GLADIUS BEND-DOWN TAB

    Two per side,opposite cut edge.

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    1"

    CUT GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    1" x 1" WALL ANGLE

    1" x 1" WALL ANGLESecond piece of wall angle is

    to be used on top of cut panel.Secure to wall along with lower wallangle, to run full length of cut panel.

    1"

    1" x 1" WALL ANGLE

    1" x 1" WALL ANGLESecond piece of wall angle is

    to be used on top of cut panel.Secure to wall along with lower wallangle, to run full length of cut panel.

    1/2"

    1/2"

    14"

    14"

    TYPICAL PERIMETER SECTION - CUT PANEL AT WALL ANGLE DETAILSCALE: 3" = 1'-0"

    TYPICAL PERIMETER SECTION - CUT PANEL AT WALL ANGLE DETAILSCALE: 3" = 1'-0"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS FIELD CUT PERIMETER

    DETAIL WITH WALL ANGLE

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.10

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • 1516" T-GRID

    1516" T-GRID

    1/2"

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    FULL GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    1/2"

    12" FROM FACE OF T-GRIDTO FACE OF GLADIUS PANEL

    FULL GLADIUS PANEL

    1" x 1" WALL ANGLE

    1" x 1" WALL ANGLE

    TYPICAL PERIMETER SECTION - FULL PANEL AT WALL ANGLE DETAILSCALE: 3" = 1'-0"

    TYPICAL PERIMETER SECTION - FULL PANEL AT WALL ANGLE DETAILSCALE: 3" = 1'-0"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS FULL PANEL PERIMETER

    DETAIL WITH WALL ANGLE

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.11

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • 14"

    CUT GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    GLADIUS BEND-DOWN TAB

    Two per side,opposite cut edge.

    1/2"

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    138"14"CUT GLADIUS PANEL

    12' STEP TRIM

    STEP TRIMSecond piece of step trim is

    to be used on top of cut panel.Secure to wall along with lower steptrim, to run full length of cut panel.

    1516" T-GRID

    1516" T-GRID

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    1/2"

    12" STEP TRIM

    STEP TRIMSecond piece of step trim is

    to be used on top of cut panel.Secure to wall along with lower steptrim, to run full length of cut panel.

    138"

    TYPICAL PERIMETER SECTION - CUT PANEL AT STEP TRIM DETAILSCALE: 3" = 1'-0"

    TYPICAL PERIMETER SECTION - CUT PANEL AT STEP TRIM DETAILSCALE: 3" = 1'-0"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS FIELD CUT PERIMETER

    DETAIL WITH STEP TRIM

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.12

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • 1516" T-GRID

    1516" T-GRID

    1/2"

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL 12" STEP TRIM

    FULL GLADIUS PANEL

    1516" T-GRID

    1/2"

    12" FROM FACE OF T-GRIDTO FACE OF GLADIUS PANEL

    12" STEP TRIM

    FULL GLADIUS PANEL

    1516" T-GRID

    138"

    138"

    TYPICAL PERIMETER SECTION - FULL PANEL AT STEP TRIM DETAILSCALE: 3" = 1'-0"

    TYPICAL PERIMETER SECTION - FULL PANEL AT STEP TRIM DETAILSCALE: 3" = 1'-0"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS FULL PANEL PERIMETER

    DETAIL STEP TRIM

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.13

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • 1516" T-GRID

    1516" T-GRID

    1 2" 12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    14"

    21 8"

    GL02

    FULL GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    1 2" 12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    14"

    21 8"

    GL02

    FULL GLADIUS PANEL

    FASTENERnot by Hunter Douglas

    TC2 CLIP To attach field cut T-grid to trim.

    TYPICAL PERIMETER SECTION - FULL PANEL AT GL02 TRIM DETAILSCALE: 3" = 1'-0"

    TYPICAL PERIMETER SECTION - FULL PANEL AT GL02 TRIM DETAILSCALE: 3" = 1'-0"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS FULL PANEL PERIMETER

    DETAIL WITH GL02 TRIM

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.14

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • 4"

    1516" T-GRID

    1516" T-GRID

    1 2" 12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    14"

    GL04

    FULL GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    1 2" 12" FROM FACE OF T-GRIDTO FACE OF GLADIUS PANEL

    14"

    FULL GLADIUS PANEL4"

    GL04

    TC2 CLIP To attach field cut T-grid to trim.

    TRIM CLIP

    TYPICAL PERIMETER SECTION - FULL PANEL AT GL04 TRIM DETAILSCALE: 3" = 1'-0"

    TYPICAL PERIMETER SECTION - FULL PANEL AT GL04 TRIM DETAILSCALE: 3" = 1'-0"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS FULL PANEL PERIMETER

    DETAIL WITH GL04 TRIM

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.15

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • 6"

    1516" T-GRID

    1516" T-GRID

    1 2" 12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    14"

    GL06

    FULL GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    1 2" 12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    14"

    FULL GLADIUS PANEL6"

    GL06

    TC2 CLIP To attach field cut T-grid to trim.

    Brace with strap.4'-0" on center, maximum

    not by Hunter Douglas

    Brace with strap.4'-0" on center, maximum

    not by Hunter Douglas

    TRIM CLIP

    TYPICAL PERIMETER SECTION - FULL PANEL AT GL06 TRIM DETAILSCALE: 3" = 1'-0"

    TYPICAL PERIMETER SECTION - FULL PANEL AT GL06 TRIM DETAILSCALE: 3" = 1'-0"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS FULL PANEL PERIMETER

    DETAIL WITH GL06 TRIM

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.16

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • 14"

    CUT GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    GLADIUS BEND-DOWN TAB

    Two per side,opposite cut edge.

    1/2"

    14"

    CUT GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    1/2"

    LX02

    TC2 CLIP To attach field cut

    T-grid to trim.

    TC2 CLIP To attach field cut

    T-grid to trim.

    21 8"

    21 8"

    LX02

    DOUBLE STICKTAPE

    34"

    34"

    DOUBLE STICKTAPE

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    12" FROM FACE OF T-GRIDTO FACE OF GLADIUS PANEL

    TYPICAL PERIMETER SECTION - CUT PANEL AT LX02 TRIM DETAILSCALE: 3" = 1'-0"

    TYPICAL PERIMETER SECTION - CUT PANEL AT LX02 TRIM DETAILSCALE: 3" = 1'-0"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS FIELD CUT PERIMETER

    DETAIL WITH LX02 TRIM

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.17

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • 14" CUT GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    GLADIUS BEND-DOWN TAB

    Two per side,opposite cut edge.

    1/2"

    14"

    CUT GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    1/2"

    TC2 CLIP To attach field cut

    T-grid to trim.

    TC2 CLIP To attach field cut

    T-grid to trim.

    31 8"

    31 8"

    LX03

    LX03

    34"

    34"

    DOUBLE STICKTAPE

    DOUBLE STICKTAPE

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    12" FROM FACE OF T-GRIDTO FACE OF GLADIUS PANEL

    TYPICAL PERIMETER SECTION - CUT PANEL AT LX03 TRIM DETAILSCALE: 3" = 1'-0"

    TYPICAL PERIMETER SECTION - CUT PANEL AT LX03 TRIM DETAILSCALE: 3" = 1'-0"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS FIELD CUT PERIMETER

    DETAIL WITH LX03 TRIM

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.18

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • 14"

    CUT GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    GLADIUS BEND-DOWN TAB

    Two per side,opposite cut edge.

    1/2"

    14"

    CUT GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    1/2"

    TC2 CLIP To attach field cut

    T-grid to trim.

    TC2 CLIP To attach field cut

    T-grid to trim.

    45 16

    "4

    5 16"

    LX04

    LX04

    34"

    34"

    DOUBLE STICKTAPE

    DOUBLE STICKTAPE

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    12" FROM FACE OF T-GRIDTO FACE OF GLADIUS PANEL

    TYPICAL PERIMETER SECTION - CUT PANEL AT LX04 TRIM DETAILSCALE: 3" = 1'-0"

    TYPICAL PERIMETER SECTION - CUT PANEL AT LX04 TRIM DETAILSCALE: 3" = 1'-0"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS FIELD CUT PERIMETER

    DETAIL WITH LX04 TRIM

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.19

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • 14"

    CUT GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    GLADIUS BEND-DOWN TAB

    Two per side,opposite cut edge.

    1/2"

    14"

    CUT GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    1/2"

    TC2 CLIP To attach field cut T-grid to trim.

    6"

    LX06

    LX06

    6"34"

    34"

    Brace with strap.4'-0" on center, maximum

    not by Hunter Douglas

    TC2 CLIP To attach field cut T-grid to trim.

    Brace with strap.4'-0" on center, maximum

    not by Hunter Douglas

    DOUBLE STICKTAPE

    DOUBLE STICKTAPE

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    12" FROM FACE OF T-GRIDTO FACE OF GLADIUS PANEL

    TYPICAL PERIMETER SECTION - CUT PANEL AT LX06 TRIM DETAILSCALE: 3" = 1'-0"

    TYPICAL PERIMETER SECTION - CUT PANEL AT LX06 TRIM DETAILSCALE: 3" = 1'-0"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS FIELD CUT PERIMETER

    DETAIL WITH LX06 TRIM

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.20

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • 14"

    CUT GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    GLADIUS BEND-DOWN TAB

    Two per side,opposite cut edge.

    1/2"

    14"

    CUT GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    1/2"

    TC2 CLIP To attach field cut

    T-grid to trim.

    TC2 CLIP To attach field cut

    T-grid to trim.

    8"

    34"

    Brace with strap.4'-0" on center, maximum

    not by Hunter Douglas

    8"

    LX08

    HANGER WIRE, 12 GA4'-0" on center, max.

    not by Hunter Douglas

    Brace with strap.4'-0" on center, maximum

    not by Hunter Douglas

    LX08

    HANGER WIRE, 12 GA4'-0" on center, max.

    not by Hunter Douglas

    DOUBLE STICKTAPE

    DOUBLE STICKTAPE

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    12" FROM FACE OF T-GRIDTO FACE OF GLADIUS PANEL 3

    4"

    TYPICAL PERIMETER SECTION - CUT PANEL AT LX08 TRIM DETAILSCALE: 3" = 1'-0"

    TYPICAL PERIMETER SECTION - CUT PANEL AT LX08 TRIM DETAILSCALE: 3" = 1'-0"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS FIELD CUT PERIMETER

    DETAIL WITH LX08 TRIM

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.21

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • 14"

    CUT GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    GLADIUS BEND-DOWN TAB

    Two per side,opposite cut edge.

    1/2"

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    14" CUT GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    1/2"

    TC2 CLIP To attach field cut

    T-grid to trim.

    TC2 CLIP To attach field cut

    T-grid to trim.

    10"

    34"

    34"

    10"

    Brace with strap.4'-0" on center, maximum

    not by Hunter Douglas

    LX10

    HANGER WIRE, 12 GA4'-0" on center, max.

    not by Hunter Douglas

    Brace with strap.4'-0" on center, maximum

    not by Hunter Douglas

    LX10

    HANGER WIRE, 12 GA4'-0" on center, max.

    not by Hunter Douglas

    DOUBLE STICKTAPE

    DOUBLE STICKTAPE

    TYPICAL PERIMETER SECTION - CUT PANEL AT LX10 TRIM DETAILSCALE: 3" = 1'-0"

    TYPICAL PERIMETER SECTION - CUT PANEL AT LX10 TRIM DETAILSCALE: 3" = 1'-0"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS FIELD CUT PERIMETER

    DETAIL WITH LX10

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.22

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS

  • 14"

    CUT GLADIUS PANEL

    1516" T-GRID

    1516" T-GRID

    1/2"

    1516" T-GRID

    1516" T-GRID

    1/2"

    TC2 CLIP To attach field cut

    T-grid to trim.

    TC2 CLIP To attach field cut

    T-grid to trim.11

    5 8"

    34"

    34"

    Brace with strap.4'-0" on center, maximum

    not by Hunter Douglas

    115 8"

    Brace with strap.4'-0" on center, maximum

    not by Hunter Douglas

    LX12

    HANGER WIRE, 12 GA4'-0" on center, max.

    not by Hunter Douglas

    LX12

    HANGER WIRE, 12 GA4'-0" on center, max.

    not by Hunter Douglas

    DOUBLE STICKTAPE

    DOUBLE STICKTAPE

    GLADIUS BEND-DOWN TAB

    Two per side,opposite cut edge.

    12" FROM FACE OF T-GRIDTO FACE OF GLADIUS PANEL

    TYPICAL PERIMETER SECTION - CUT PANEL AT LX12 TRIM DETAILSCALE: 3" = 1'-0"

    12" FROM FACE OF T-GRID

    TO FACE OF GLADIUS PANEL

    14"

    CUT GLADIUS PANELTYPICAL PERIMETER SECTION - CUT PANEL AT LX12 TRIM DETAILSCALE: 3" = 1'-0"

    5015 Oakbrook Parkway, Suite 100

    Norcross, GA 30093

    O 800.366.4327

    F 770.806.0214

    CTSpecialtyCeilings.com

    All rights reserved. This drawing is the property of

    CertainTeed Ceilings Corporation. It may not be

    copied or multiplied, neither wholly nor partly. It

    may not be submitted for perusal to third parties.

    GLADIUS FIELD CUT PERIMETER

    DETAIL WITH LX12 TRIM

    PROJECT: GLADIUS PRODUCT

    SPECIFICATIONS

    DRAWING NUMBER: GLADIUS-A1.23

    SCALE: AS SHOWN

    DRAWN BY: HD ENGINEERING

    DATE: 3/6/19

    SPECIFICATIONS

    (unless noted otherwise)

    MATERIAL: .032" ALUMINUM

    FINISH: PAINT | POWDER COAT |

    DECORATED WOOD FINISH

    PERFORATION: CONTACT HUNTER

    DOUGLAS