Upload
others
View
9
Download
0
Embed Size (px)
Citation preview
PROPOSED SITE SECTIONCASA MIA STUART HOWARD
MEMBERS AIBC - RAIC - AIA
S HA ARCHITECTS INC.
STUART HOWARD
MEMBERS AIBC - RAIC - AIA
S HA ARCHITECTS INC.Sheet No.: A4.01
Sheet Title:
Issue Date: 2013.01.29
COMMUNITY CARE FACILITY
F.G. 5
7.6'
F.G. 5
7.6'
F.G. 5
6.8'
F.G. 5
6.0'
F.G. 5
8.3'
F.G. 5
7.1'
F.G. 5
7.1'
F.G. 5
6.8'
13'-0
"12
'-10
7/8"
10'-0
"10
'-0"
ANGUS LANDS HOUSING
PRO
PER
TY L
INE
E.G. 58.50'
E.G. 46.9'
E.G. 47.4'
E.G. 51.9'
E.G. 53.8'
E.G. 57.10'
E.G. 57.20'
E.G. 55.6'
E.G. 56.4'
E.G. 56.0'E.G. 51.00'
E.G. 54.60'
E.G. 54.80'
E.G. 55.00'
E.G. 54.80'
E.G. 54.8'
E.G. 00.00'
PRO
PER
TY L
INE
FEN
CE
SETB
ACK
LIN
E
E.G. 57.30'
SW MARINE DR
E.G. 56.60'
+ 10.00 FT
+ 20.00 FT
+ 30.00 FT
+ 40.00 FT
+ 50.00 FT
+ 60.00 FT
+ 70.00 FT
+ 80.00 FT
+ 90.00 FT
+ 100.00 FT
CASA MIA
SUITES STORAGE
SUITES SUITES
SUITES SUITES
PROPOSED BUILDING
COURTYARD
CASA MIA
0 5 10 20 30 50 ft
PROPOSED BUILDING SECTIONCASA MIA STUART HOWARD
MEMBERS AIBC - RAIC - AIA
S HA ARCHITECTS INC.
STUART HOWARD
MEMBERS AIBC - RAIC - AIA
S HA ARCHITECTS INC.Sheet No.: A4.02
Sheet Title:
Issue Date: 2013.01.29
COMMUNITY CARE FACILITY
F.G. 5
7.6'
F.G. 5
7.6'
F.G. 5
6.8'
F.G. 5
6.0'
F.G. 5
8.3'
F.G. 5
7.1'
F.G. 5
7.1'
F.G. 5
6.8'
el.58.30'MAIN FLOOR
(17.77m)
el.45.39'BSMNT FLOOR
(13.83m)
13'-0
"12
'-10
7/8"
el.71.30'SECOND FLOOR
(21.73m)
el.81.30'THIRD FLOOR
(24.78m)
el.91.30'T/O PARAPET
(27.82m)
10'-0
"10
'-0"
F.G. 57.6'
F.G
. 58.3
'
F.G. 5
7.4'
LOWER COURTYARD
LINE OF EXISTING GRADE @ SECTION
CORRIDOR
CARE ROOMCORRIDOR
COR. STORAGE
CARE ROOM
CARE ROOM CARE ROOM
CARE ROOM
CARE ROOM CARE ROOM
DINING
LAUNDRYHALLKITCHEN
LOUNGE
CARE ROOM
NURSERY
0 5 10 20 30 50 ft
PROPOSED BUILDING SECTIONCASA MIA STUART HOWARD
MEMBERS AIBC - RAIC - AIA
S HA ARCHITECTS INC.
STUART HOWARD
MEMBERS AIBC - RAIC - AIA
S HA ARCHITECTS INC.Sheet No.: A4.03
Sheet Title:
Issue Date: 2013.01.29
COMMUNITY CARE FACILITY
F.G. 5
7.6'
F.G. 5
7.6'
F.G. 5
6.8'
F.G. 5
6.0'
F.G. 5
8.3'
F.G. 5
7.1'
F.G. 5
7.1'
F.G. 5
6.8'
el.58.30'MAIN FLOOR
(17.77m)
el.45.39'BSMNT FLOOR
(13.83m)
13'-0
"12
'-10
7/8"
el.71.30'SECOND FLOOR
(21.73m)
el.81.30'THIRD FLOOR
(24.78m)
el.91.30'T/O PARAPET
(27.82m)
10'-0
"10
'-0"
F.G. 57.6'
F.G. 5
7.4'
F.G
. 58.3
'
LOWER COURTYARD
LINE OF EXISTING GRADE @ SECTION
CORRIDOR
CARE ROOMCORRIDOR
COR. STORAGE
CARE ROOM
CARE ROOMCARE ROOM
CARE ROOM
HALL
HALL
HALL
ELEVATOR
NURSESTATION
NURSESTATION
0 5 10 20 30 50 ft
PROPOSED BUILDING SECTIONCASA MIA STUART HOWARD
MEMBERS AIBC - RAIC - AIA
S HA ARCHITECTS INC.
STUART HOWARD
MEMBERS AIBC - RAIC - AIA
S HA ARCHITECTS INC.Sheet No.: A4.04
Sheet Title:
Issue Date: 2013.01.29
COMMUNITY CARE FACILITY
el.58.30'MAIN FLOOR
(17.77m)
el.45.39'BSMNT FLOOR
(13.83m)
13'-0
"12
'-10
7/8"
el.71.30'SECOND FLOOR
(21.73m)
el.81.30'THIRD FLOOR
(24.78m)
el.91.30'T/O PARAPET
(27.82m)
10'-0
"10
'-0"
F.G. 54.6'
CORRIDOR
CORRIDOR
DRIVEWAY
LOWER COURTYARD
ELEVATOR
MECHANICAL
SERVICE LANE
LINE OF EXISTING GRADE @ SECTION
CORRIDORCOR.
CARE ROOM CORRIDOR
CARE ROOM
CARE ROOM
0 5 10 20 30 50 ft