Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
JON C. MOOK, SIOR EXECUTIVE VICE PRESIDENTc: 403-616-5239e: [email protected]
EMILY GOODMAN ASSOCIATEc: 403-862-4348e: [email protected]
SALEFOR
4,904 SF
4950-106th Avenue SE Uni t s 137 & 141
JON C. MOOK, SIOR EXECUTIVE VICE PRESIDENTc: 403-616-5239e: [email protected]
EMILY GOODMAN ASSOCIATEc: 403-862-4348e: [email protected]
Building OptiOns:
TOTAL SIZE: Office: 2,501 sq.ft. Warehouse: 2,403 sq.ft. Total: 4,904 sq.ft.
PURCHASE PRICE: $1,350,000.00 ($275.00 psf)
PROPERTY TAXES: $20,577.69 (for 2019)
CONDO FEES: $10,200.00 ($5,100.00 per unit) per year
ZONING: I-G (Industrial General)
CEILING HEIGHT: 18’ clear
LOADING: 2-12’x14’ Drive-in
YEAR BUILT: 2011
ELECTRICAL: 225 amp, 120/208 volt, 3 phase 2 independent panels
AVAILABLE: 30 to 60 days
COMMENTS:
PROPERTY DETAILS
› High quality office improvements › Hotsy pressure washer system › Epoxy coated warehouse flooring › Computers / furniture negotiable › Direct exposure to 106 Avenue SE with
quick access to Barlow Trail
JON C. MOOK, SIOR EXECUTIVE VICE PRESIDENTc: 403-616-5239e: [email protected]
EMILY GOODMAN ASSOCIATEc: 403-862-4348e: [email protected]
MAIN FLOOR PLAN
61 ft.
41 ft.
JON C. MOOK, SIOR EXECUTIVE VICE PRESIDENTc: 403-616-5239e: [email protected]
EMILY GOODMAN ASSOCIATEc: 403-862-4348e: [email protected]
SITE PLAN
110
2.75 INTEGRALLY COLORED CONCRETE WALK
A
5050 106 AVE SE
1
C
94.937
BUILDING 'A' BUILDING 'B'
1 3
4 H
R F
IRE
WAL
L
22.72923.863
20.037
10.50214.669
2 H
R F
IRE
RAT
ED W
ALL
1 2 1 3 1 2 1 247.469 47.469
1129.155 sqm (12155 sqft)
8.683
8.921
EXISTINGBUILDING
1033
.80
44.6
0
109.75
67.0
1
59.91
12.75
BOW 0.32BOW 0.35
BOW 0.40
0.144
1129.155 sqm (12155 sqft)
P/L TO BLDG
2.80 INTEGRALLY COLORED CONCRETE WALK
ELEC STUBCABLE PED.
EXISTINGBUILDING
0.100P/L TO BLDG
A
A
B B
ELEC MANHOLE
EXISTING CHAINLINK FENCE
PRECASTCONC.PICNICTABLE
4.5m x 4.5m AMENITYSPACE SEE DETAIL 1/L1
FREE-STANDING ADDRESS SIGN SEE DETAIL 3/A5
ASPHALT PARKING
CONCRETEAPRON
NEW ASPHALTDRIVEWAY
LS
WHEELCHAIR RAMPAS PER CITY STANDARDS
YELLOW PAINTED LINES
NEW
2.0
m W
ALK
LSLSLSLS
LIGHT STANDARD -TYP 4 LOCATIONS
ASPHALT PARKING
NEW
ASP
HAL
TD
RIV
EWAY
CO
NC
RET
EAP
RO
N
SLOPE
0.50 STD C&G 7.60 LG
EXISTING 1.40 SEP WALK
7.5m LANDSCAPE SETBACK
6m L
AND
SCAP
E SE
TBAC
K
1.2m SETBACK
0.50
STD
C&G
--- L
G
SCREENED WASTE/RECYCLE ENCLOSURE - SEE DETAIL 4/S5
WHEELSTOPTYPICAL - SEEDETAIL ON DWG A1.1
6.000TYP
2.600TYP
23.9283.0057.200NEW
DRIVEWAY
3.0059.38848.813
4.000
1.00
0
MECH/ELEC ROOM
1.500
3.00018.6692.60022.200
2.000
22.2012.59918.2003.469
7.184
5.4007.229
7.500
6.80
13.
000
7.20
03.
000
24.5
99
6.300 10.650
4.000
NEW TRANSFORMER LOCATIONc/w BOLLARDS
3.6m CONCRETE APRON
6.000
3.6m CONCRETE APRON
T/O SLABEL 34.00
T/O SLABEL 34.00
EXISTING HYDRANT38.356
EXISTING SIGNMAIL BOX
2.600
2.800
20.102
RIGHT INRIGHT OUT
C
2 CLASS 2 BIKE RACKS
NEW HYDRANT
22.947
MU
TUAL
AC
CES
S EA
SEM
ENT
PLAN
111
093
930
MUTUAL ACCESS EASEMENT PLAN 111 093 930
MUTUAL ACCESS EASEMENT PLAN 111 093 930
C C C C
4.00%
0.80%0.80% 0.80%
4.30%
3.00%2.00%
3.80%
3.80%
4.00%
6.00%
SITE & BUILDING NOTESLEGAL DESCRIPTION:LOT 14, BLOCK 14, PLAN 0611776
MUNICIPAL ADDRESS :4950 106 AVE. S.E.
LOT AREA:7248.7031sqm = 1.79 ACRES = .725 HA
GROSS FLOOR AREA -GFA (2 BUILDINGS TOTAL):2258.310 sqm (24 309sqft)
PARKING STALLS REQUIRED:OFFICE - 1 STALL/50sqm = 1129.155/50 =22.583 STALLS
TOTAL STALLS REQUIRED: 34 STALLSTOTAL STALLS PROVIDED: 42 STALLS INCLUDING 2 H/C
WAREHOUSE - 1STALL/100sqm = 1129.155/100 = 11.292 STALLS
ZONING:I-G - INDUSTRIAL - GENERAL
BUILDING 'A' FOOTPRINT AREA:
BUILDING 'B' FOOTPRINT AREA:
FLOOR AREA RATIO -FAR (GFA/LOT AREA):2258.310 sqm/7248.703 sqm = .31 FAR
1129.155 sqm (12155 sqft)ASSUME 1/2 OFFICE AREA, 1/2 WAREHOUSE AREA
ASSUME 1/2 OFFICE AREA, 1/2 WAREHOUSE AREA1129.155 sqm (12155 sqft)
BUILDING CODE REVIEW:
1 STOREY, FACING 3 STREETS, UNSPRINKLEREDBUILDINGS CONFORM TO 3.2.2.55 & 3.2.2.71, ABC 2006GROUP F-2: WAREHOUSE
OCCUPANCY:GROUP D: OFFICE
BUILDING CODE REVIEW:
COMBUSTIBLE OR NON-COMBUSTIBLE CONSTRUCTION
LOAD BEARING WALLS, COLUMNS AND ARCHES SUPPORTING AN ASSEMBLY SHALL HAVE A FIRE RESISTANCE RATING NOT LESS THAN
MEZZANINES SHALL HAVE, IF COMBUSTIBLE CONSTRUCTION, A FIRE RESISTANCE RATING NOT LESS THAN 45 MINUTES
45 MINUTES OR BE NON-COMBUSTIBLE.LOAD BEARING WALLS, COLUMNS AND ARCHES SUPPORTING A FIRE SEPARATION SHALL HAVE A FIRE RESISTANCE RATING NOT LESS THAN THAT REQUIRED FOR THE FIRE SEPARATION.
3.2.3.1 LIMITING DISTANCE AND AREA OF UNPROTECTED OPENINGS EAST WALL - BUILDING B: AREA OF EAST WALL - 23.863 x 6.5 = 155.1sqm LIMITING DISTANCE - 0.1m PERMITTED AREA OF U.P.O. - 0% FIRE RATING OF WALL - 2HRS/NON-COMBUSTIBLE
3.3.1.1.(2) EACH SUITE IN OTHER THAN BUSINESS AND PERSONAL SERVICES OCCUPANCIES SHALL BE SEPARATED FROM ADJOINING SUITES BY A FIRE SEPARATION EQUAL TO 45MIN.
3.2.3.5 WALL WITH LIMITING DISTANCE LESS THAN 1.2m OPENINGS IN A WALL WITH A LIMITING DISTANCE LESS THAN 1.2m SHALL BE PROTECTED WITH CLOSURES WHOSE FIRE PROTECTION RATING IS IN CONFORMANCE WITH THE F.R.R. REQUIRED FOR THE WALL.
SIGNAGE LEGEND
A 'PRIVATE PROPERTY' SIGN AND'CAUTION & WATCH YOUR STEP' SIGNMOUNTED ON 2440mm POLE
B HANDICAPPED PARKING SIGNMOUNTED ON 1220mm POLE
C 'NO PARKING ANYTIME/FIRE LANE'
EXISTING STORM SEWER LINE
EXISTING SANITARY SEWER LINE
EXISTING WATER LINE
MANHOLE
EXISTING GROUND ELEVATION
PROPOSED FINISHED GRADE
CATCH BASIN
FIRE HYDRANT
NOTE: ADD 1000m TO ALL ELEVATIONS
LEGEND
ST
LS NEW LIGHT STANDARD, - LUMEX OPCS-2METAL HALIDE LAMP
MH
EXISTING LIGHT STANDARD
EXISTING POWER POLE
EXISTING OVERHEAD POWER LINEP P P
TO BE INCLUDED IN THE STRUCTURAL
STEEL DECK CONTRACTOR: 1. SUPPLY & INSTALL THE STEEL PANEL ON THE GARBAGE ENCLOSURE GATE.
2. SUPPLY & INSTALL ROOF ACCESS (NO BACKING). 1. SUPPLY & INSTALL THE FLASHINGROOFING CONTRACTOR:
STEEL SCOPE OF WORK.
HATCH.
AS SPECIFIED IN THE DRAWINGS. 1. SUPPLY & INSTALL THE BLOCK TIESMASONRY CONTRACTOR:
RESPONSIBLE FOR THE ROUGHBUCKS 2. THE GENERAL CONTRACTOR IS
FOR THE MASONRY.
THE BUILDING DURING CONSTRUCTION.
ACCESS LADDER & CAGE, ETC., ARE BOLLARDS, HINGES, GATES, ROOF 1. ALL MISCELLANEOUS STEEL, INCLUDINGSTRUCTURAL STEEL CONTRACTOR:
FOOTING & FROST WALL CONTRACTOR:
BE RESPONSIBLE FOR HOARDING OF 1. THE GENERAL CONTRACTOR SHALLGENERAL CONTRACTOR: MECHANICAL AND ELECTRICAL CONTRACTORS:
ASSEMBLY APPROVED BY UNDERWRITERS LABORATORIES 1. CONTRACTORS TO PROVIDE A FIRE RATED
FOR ALL PENETRATIONS THROUGH FIRE RATED WALLS TO THE GENERAL CONTRACTOR. NO PENETRATIONS SHALL BE PERMITTED THROUGH ANY FIRE WALLS WITHOUT WRITTEN PERMISSION FROM THE CONSTRUCTION MANAGER.
WALLS OR FIRE WALLS ARE TO BE PROPERLY 2. ALL PENETRATIONS THROUGH ANY FIRE RATED
SEALED WITH AN APPROVED FIRE CAULK IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ENSURE THAT THE SIZE OF THE PENETRATION DOES NOT EXCEED MAXIMUM DIAMETER SPECIFIED IN THE MANUFACTURER'S RECOMMENDATIONS.
LANDSCAPE CONTRACTOR
APPROVAL PRIOR TO COMMENCING WORK.
2. PROVIDE A SPRINKLER LAYOUT AND SLEEVE LAYOUT PLAN FOR TELSEC
3. UNDERGROUND IRRIGATION WIRING TO BE RUN IN PVC PIPE OR CONDUIT. 4. IRRIGATION SYSTEM HEADER BOXES ARE NOT TO BE LOCATED IN CONCRETE. LOCATE IN SHRUBBERY WHERE POSSIBLE.
1. LANDSCAPE CONTRACTOR TO USE STERILIZED LOAM ONLY FOR ALL LANDSCAPE AREAS.
WALL SCUPPER LOCATIONS. 3. SUPPLY & INSTALL SCREENS AT ALL
1. SUPPLY & INSTALL THE FOOTING FOR THE SIGN BASE AS DETAILED.
ALL WALL SCUPPER LOCATIONS. 4. SUPPLY & INSTALL FRAMES AROUND
CONTRACTOR NOTES
GENERAL NOTES TO ALL CONTRACTORS
SEALANTS ARE TO BE SUPPLIED AND INSTALLED BY
1. WHERE SEALANTS ARE REQUIRED BETWEEN PRODUCTS INSTALLED BY DIFFERENT TRADES, THE
THE TRADE THAT IS LAST TO PERFORM THE INSTALLATION OF THEIR PRODUCT NEXT TO THE PREVIOUSLY INSTALLED ITEMS. ALL CAULKING AND CAULKING PRODUCTS, INCLUDING JOINT CLEANER, PRIMER AND JOINT FILLER MUST BE SELECTED AND APPLIED BASED ON THEIR SPECIFIC REQUIRED FUNCTION AND MUST COMPLY WITH DETAILED CAULKING REQUIREMENTS AND SPECIFICATIONS AVAILABLE UPON REQUEST FROM THE CLIENT.
PRECAST CONCRETE CONTRACTOR: 1. SUPPLY & INSTALL THE MATERIALS NECESSARY FOR THE DETAILED GARBAGE ENCLOSURE.
MASONRY AND PRECAST IS COMPLETE
THE STEEL CONTRACTOR IS THEN RESPONSIBLE TO RETURN AFTER THE
2. THE STEEL CONTRACTOR SHALL WELD DECK ANGLES BEFORE THE MASONRY AND/OR PRECAST CONTRACTORS ARE COMPLETE.
TO INSTALL THE BOLTS.
OF THE GARBAGE & RECYCLE ENCLOSURE. 5. SUPPLY & INSTALL THE FLASHING ON THE PRECAST
DESCRIPTION
REVISIONSNO. DATE
SUBMITTED FOR BP APR 25/11
TPC-EAST-2
Calgary, Alberta4950 106 Ave SE
PROJECT
DRAWING TITLE
SITE PLAN
PROJECT NO: TPC-220BPDATE: MARCH 18, 2011DRAWN BY: T. IRVINGSCALE: 1:300DRAWING NO: TPC-220BP_SITEJOB NO: TPC-220
A1
DRAWING NO.
0
REVISION NO.
THIS COPYRIGHTED DRAWING IS THE PROPERTY OF THE TELSEC GROUP.NO PORTION OF THIS DRAWING MAY BE REPRINTED OR REPRODUCEDIN ANY MANNER WITHOUT PREVIOUS WRITTEN CONSENT.
GENERAL NOTES
STRUCTURAL, ELECTRICAL AND MECHANICAL PLANS. ALL DIMENSIONSDRAWINGS MUST BE CROSS REFERENCED TO ALL ARCHITECTURAL,
DRAWINGS AND SPECIFICATIONS MUST BE VERIFIED ON SITE.
DO NOT SCALE THIS DRAWING.THE ARCHITECT/ENGINEER/DESIGNER PRIOR TO CONSTRUCTION.ANY DISCREPANCIES, ERRORS OR OMISSIONS MUST BE REPORTED TO
DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL REVIEWED ANDAPPROVED BY THE AUTHORITY HAVING JURISDICTION. THIS AUTHORITY, BASED ONAPPLICABLE CODES, MAY REQUIRE REVISIONS AND/OR ADDITIONS AND THIS MAYRESULT IN EXTRA COSTS. THESE COSTS ARE UNFORESEEN AND THEREFORE, ARE THE RESPONSIBILITY OF THE OWNER AND/OR CONTRACTOR.
TELSEC PROPERTY CORPORATION3150 114 Ave. S.E.
Calgary, Alberta
Ph: 403.230-8366
240 - 8 Ave NWCalgary Alberta
KEY PLANN.T.S.
4950
JON C. MOOK, SIOR EXECUTIVE VICE PRESIDENTc: 403-616-5239e: [email protected]
EMILY GOODMAN ASSOCIATEc: 403-862-4348e: [email protected]
The information contained herein has been gathered from sources deemed reliable, but is not warranted as such and does not form any part of any future contract. This offering may be altered or withdrawn at any time without notice.
SUBJECT PROPERTY
LOCATION
106 AVENUE SE
50 STREET SE
48 S
TREE
T SE
BA
RLO
W T
RA
IL S
E
52 STREET SE
106 AVENUE SE
STON
EY TR
AIL SE
GLENMORE TRAIL
DEERFOOT TRAIL
SUBJECT PROPERTY