2018 IRC Update
Copyright 2017 International Code Council 1
2018 IRC Transition from 2012 IRC2018 IRC Transition from 2012 IRCBased on the International Residential Code® (IRC®)
Identify changes between the 2012 and 2018 IRC
Apply code requirements to design, plan submittals and/or inspection.
2018 IRC Transition from the 2012 IRC
Identify the differences between 2012 and 2018 IRC.
Explain how the changes impact design and construction under the IRC
2018 IRC Transition from the 2012 IRC
Nic
k Yo
ungs
on-l
ink
to -
http
://ny
phot
ogra
phic
.com
/TipsTipsGuide to a successful class: Slides contain some text and
iconic images to help you learn. Text and commentary is in the
handout. Follow along in the course
handout. Ask Questions, ask questions,
ASK QUESTIONS!!!!
2018 IRC Transition from the 2012 IRC
2018 IRC Update
Copyright 2017 International Code Council 2
Scope and Administration and DefinitionsScope and Administration and Definitions
Part 1
R 101.2, R202 Scope – Accessory StructuresR 101.2, R202 Scope – Accessory Structures
Maximum height from 2 to 3 stories
Technical requirements removed from definition
Unlimited in area
2018 IRC Transition from the 2012 IRC
2015
R101.2 ScopeR101.2 Scope
2018 IRC Transition from the 2012 IRC
Exceptions 1 through 5
2018 R104.11 Alternative Materials and Methods of ConstructionR104.11 Alternative Materials and Methods of Construction2015 Reason for disapproval
2018 Application, Equivalencies
2018 IRC Transition from the 2012 IRC
2018 IRC Update
Copyright 2017 International Code Council 3
R105.1, R110.1, R202Change of OccupancyR105.1, R110.1, R202Change of Occupancy
2018 IRC Transition from the 2012 IRC
2018 R105.3.1.1 Existing Buildingsin Flood Hazard AreasR105.3.1.1 Existing Buildingsin Flood Hazard Areas
Determination of substantial improvement by building official
Related provisions consolidated in R105.3.1.1.
2018 IRC Transition from the 2012 IRC
2015
R202 Definition of AccessR202 Definition of Access
2018 IRC Transition from the 2012 IRC
2018
Building PlanningBuilding Planning
Chapter 3
2018 IRC Update
Copyright 2017 International Code Council 4
Table 301.2(1) Climatic and Geographic Design CriteriaTable 301.2(1) Climatic and Geographic Design Criteria
2018 IRC Transition from the 2012 IRC
2015 2018Special wind region ACCA Manual J
Windborne debris zone
R301.2.1 Wind Design Criteria and Wind Speed MapsR301.2.1 Wind Design Criteria and Wind Speed MapsFigure R301.2(5)B Regions Where Wind Design Is Required >140 mph Vult non-hurricane areas (108 Vasd) >130 mph Vult hurricane areas (101 Vasd)
2018 IRC Transition from the 2012 IRC
2015
R301.2.1.1.1 Sunrooms R301.2.1.1.1 Sunrooms R301.2.1 Wind design
criteria Sunrooms to comply
with AAMA/NPEA/NSA 2100-12.
Habitable and non-habitable
Conditioned and unconditioned
2018 IRC Transition from the 2012 IRC
2015 R301.2.1.2 Protection of Openings in Wind Borne Debris RegionsR301.2.1.2 Protection of Openings in Wind Borne Debris Regions Prescriptive attachment of wood
structural panels: Mean roof height limit increased
from 33 to 45 ft. To permit on 3-story buildings
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Update
Copyright 2017 International Code Council 5
R301.2.1.4 Wind Exposure CategoryR301.2.1.4 Wind Exposure Category Wind Exposure Category A deleted Wind Exposure Category D: Unobstructed areas ≥5,000 ft.: Open water Mud and salt flats Unbroken ice fields Includes hurricane-prone regions.
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Transition from the 2012 IRC
2018
R301.3 Story Height R301.3 Story Height Story height 11ft. 7in.: Wood and steel wall
framing Insulated concrete SIP walls
Masonry wall height is limited to 13 ft 7in.
2018 IRC Transition from the 2012 IRC
11 ft. 7 in. Max.
Story height
Story height
2015 R302.1 Exterior WallsR302.1 Exterior Walls
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Update
Copyright 2017 International Code Council 6
R302.1 Exterior WallsR302.1 Exterior Walls
2018 IRC Transition from the 2012 IRC
Fireblocking not required
2018 R302.2Townhouse SeparationR302.2Townhouse Separation
2015
2018 IRC Transition from the 2012 IRC
R302.2 Townhouse SeparationR302.2 Townhouse Separation
2018 IRC Transition from the 2012 IRC
2018 R302.2 Townhouse SeparationR302.2 Townhouse Separation
2018 IRC Transition from the 2012 IRC
2018
2018 IRC Update
Copyright 2017 International Code Council 7
R302.3 Two-Family Dwelling SeparationR302.3 Two-Family Dwelling Separation
2018 IRC Transition from the 2012 IRC
2018 R302.13 Fire Protection of FloorsR302.13 Fire Protection of Floors
2018 IRC Transition from the 2012 IRC
Moved from Chapter 5 to the fire-resistant construction provisions of Section R302.
Does not regulate penetrations or openings in membrane.
2015
R302.13 Fire Protection of Floors above Crawl SpacesR302.13 Fire Protection of Floors above Crawl Spaces
2018 IRC Transition from the 2012 IRC
2018 R303.7, R303.8 Stairway IlluminationR303.7, R303.8 Stairway Illumination Interior and exterior in
separate sections Interior to illuminate
treads and landings Exterior light source
at top landing Bottom landing
accessing basement
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Update
Copyright 2017 International Code Council 8
R304.1 Minimum Habitable Room AreaR304.1 Minimum Habitable Room Area
Deletes 120 square feet minimum area
2018 IRC Transition from the 2012 IRC
2015 R305Ceiling HeightR305Ceiling Height 6 feet 8 inches: Bathrooms Toilet rooms Laundry rooms
6 feet, 4 inches all basements: Beams Girders Ducts Other obstructions
2018 IRC Transition from the 2012 IRC
2015
R308.4.2 Glazing Adjacent to DoorsR308.4.2 Glazing Adjacent to Doors Glazing installed
perpendicular to a door < 24 inches from door Safety glazing if on hinge
side of an in-swinging door
2018 IRC Transition from the 2012 IRC
2015 R308.4.2 Glazing Adjacent to DoorsR308.4.2 Glazing Adjacent to Doors
2018 IRC Transition from the 2012 IRC
2018
2018 IRC Update
Copyright 2017 International Code Council 9
2018 IRC Transition from the 2012 IRC
R308.4.2 Glazing Adjacent to Doors
R308.4.2 Glazing Adjacent to Doors
2018 R308.4.4 Glazing in Guards and RailingsR308.4.4 Glazing in Guards and Railings
2018 IRC Transition from the 2012 IRC
2018
R308.4.4 Glazing in Guards and RailingsR308.4.4 Glazing in Guards and Railings
2018 IRC Transition from the 2012 IRC
Glass infill panels are not structural balusters
2018 R3804.5 Glazing and Wet SurfacesR3804.5 Glazing and Wet Surfaces
2018 IRC Transition from the 2012 IRC
Not safety glazing when ≥ 60 in. from edge of Shower Sauna Steam room
2015
2018 IRC Update
Copyright 2017 International Code Council 10
R308.4.7 Glazing Adjacent to the Bottom Stair LandingR308.4.7 Glazing Adjacent to the Bottom Stair Landing
2018 IRC Transition from the 2012 IRC
Area in front of the plane of the bottom tread.
2015 R308.4.7 Glazing Adjacent to the Bottom Stair LandingR308.4.7 Glazing Adjacent to the Bottom Stair Landing
2018 IRC Transition from the 2012 IRC
2018
Hazardous location
R310 Emergency Escape and Rescue OpeningsR310 Emergency Escape and Rescue Openings Reorganized Separate provisions
for windows and doors Less precise sill height
measurement Grade floor or below
grade openings 5.0
2018 IRC Transition from the 2012 IRC
2015 R310.1 Emergency Escape and Rescue Openings R310.1 Emergency Escape and Rescue Openings
2018 IRC Transition from the 2012 IRC
2018
2018 IRC Update
Copyright 2017 International Code Council 11
R310.3 Area Wells for Emergency Escape and Rescue DoorsR310.3 Area Wells for Emergency Escape and Rescue Doors
2018 IRC Transition from the 2012 IRC
Bulkhead enclosure ------------------------ Area well
2018R310.3 Area Wells for Emergency Escape and Rescue Doors
R310.3 Area Wells for Emergency Escape and Rescue Doors
2018 IRC Transition from the 2012 IRC
2018
R310.5, R310.6 Emergency Escape and Rescue Openings for Additions, Alterations and Repairs
R310.5, R310.6 Emergency Escape and Rescue Openings for Additions, Alterations and Repairs No additional
emergency escape and rescue openings: Basement addition with
access to an emergency escape and rescue opening
Alterations or repairs to an existing basement unless new bedroom
2018 IRC Transition from the 2012 IRC
2015R311.7.1 and R311.7.8 Handrail Projection
R311.7.1 and R311.7.8 Handrail Projection
2018 IRC Transition from the 2012 IRC
2018
2018 IRC Update
Copyright 2017 International Code Council 12
R311.7.1 and R311.7.8 Handrail ProjectionR311.7.1 and R311.7.8 Handrail Projection
2018 IRC Transition from the 2012 IRC
2018R311.7.3 Vertical RiseR311.7.3 Vertical Rise
2018 IRC Transition from the 2012 IRC
2018
2012 2015 2018144 in. 147 in. 151 in.
R311.7.5.1 Stair RisersR311.7.5.1 Stair Risers Open risers based on
distance above grade or the floor below (not total rise)
Open risers permitted on spiral stairways
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Transition from the 2012 IRC
R311.7.11, R311.7.12 Alternating tread devices & Ships ladders
R311.7.11, R311.7.12 Alternating tread devices & Ships ladders
2015 & 2018
2018 IRC Update
Copyright 2017 International Code Council 13
R311.8 RampsR311.8 Ramps Ramps that serve the
required egress door: 1:12 slope Unless infeasible
Other ramps: 1:8 slope
2018 IRC Transition from the 2012 IRC
2015 R312.1GuardsR312.1Guards Deletes provision for
measuring guard height from surface of adjacent fixed seating
2018 IRC Transition from the 2012 IRC
2015
R312.1 GuardsR312.1 Guards
2018 IRC Transition from the 2012 IRC
2018 R314Smoke AlarmsR314Smoke Alarms Battery-operated permitted
for alterations, repairs, and additions to existing buildings
Household fire alarm systems no longer require monitoring by an approved supervising station.
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Update
Copyright 2017 International Code Council 14
R314Smoke AlarmsR314Smoke AlarmsR314.3 Location
4. ≥ 3 ft horizontally from door of a bathroom
R314.3.1 Minimum distance from cooking appliances
Type of alarm Separation
Ionization 20 ft
Ionization with alarm-silencing switch 10 ft
Photoelectric 6 ft
2015
2018 IRC Transition from the 2012 IRC
R314 Smoke AlarmsInterconnection always requiredR314 Smoke AlarmsInterconnection always required
2018 IRC Transition from the 2012 IRC
2018
R315 Carbon Monoxide AlarmsR315 Carbon Monoxide Alarms2015 IRC 2018 IRC
• House wiring & battery backup
• Exterior work OK• Attached garage …• CO alarm in bedroom …• CO detection systems -
locations per code
• Interconnection required for multiple CO alarms
2018 IRC Transition from the 2012 IRC
R322.3 Coastal High-Hazard Flood Zones R322.3 Coastal High-Hazard Flood Zones
2018 IRC Transition from the 2012 IRC
2015 & 2018
2018 IRC Update
Copyright 2017 International Code Council 15
R324.6 Roof Access for PV Solar Energy SystemsR324.6 Roof Access for PV Solar Energy Systems
2018 IRC Transition from the 2012 IRC
2018 R324.6.2.2 Solar Panels Near Emergency Escape and Rescue Openings
R324.6.2.2 Solar Panels Near Emergency Escape and Rescue Openings
2018 IRC Transition from the 2012 IRC
2018
R325MezzaninesR325Mezzanines Mezzanine. An
intermediate level or levels between the floor and ceiling of any story.
Limitations on ceiling height and openness consistent with IBC
2018 IRC Transition from the 2012 IRC
2015 R325.3 Mezzanine Area LimitationR325.3 Mezzanine Area Limitation
2018 IRC Transition from the 2012 IRC
2018
2018 IRC Update
Copyright 2017 International Code Council 16
R325.6 and R202 Habitable AtticsR325.6 and R202 Habitable Attics
2018 IRC Transition from the 2012 IRC
2018 R326 Swimming Pools, Spas and Hot TubsR326 Swimming Pools, Spas and Hot Tubs The design and
construction of pools and spas shall comply with the International Swimming Pool and Spa Code (ISPSC).
Appendix G Swimming Pools, Spas and Hot Tubs
2018 IRC Transition from the 2012 IRC
2015
FoundationsFoundations
Chapter 4
R403.1.1 Minimum Footing SizeR403.1.1 Minimum Footing Size Expanded tables Type of structure
Light frame Veneer Concrete
Type of foundation Slab on grade Crawl space Basement
Expanded tables Roof snow load 32-ft. wide house No. of stories
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Update
Copyright 2017 International Code Council 17
R403.1.1 Minimum Footing SizeR403.1.1 Minimum Footing Size
2018 IRC Transition from the 2012 IRC
2015Minimum Required FootingMinimum Required Footing
Two-story house with slab on grade foundation: Light-frame construction Soil-bearing strength @ 1500 psf Roof Live Load @ 20 psf 32ft. wide building with interior load-bearing wall
2018 IRC Transition from the 2012 IRC
2015
R403.1.3 Footing and Stem Wall Reinforcing in Seismic Design Categories D₀, D₁, and D₂R403.1.3 Footing and Stem Wall Reinforcing in Seismic Design Categories D₀, D₁, and D₂
Defines required reinforcing
Updated figures
2018 IRC Transition from the 2012 IRC
2015 R403.1.6Foundation AnchorageR403.1.6Foundation Anchorage Anchor bolts in the middle
third of sill plate Measured to edge of bolt (Optimum 1¾ in.)
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Update
Copyright 2017 International Code Council 18
Table R403.3(1) Insulation requirements
for frost protected footings
Table R403.3(1) Insulation requirements
for frost protected footings
2018
2018 IRC Transition from the 2012 IRC
Table R403.4 Crushed Stone FootingsTable R403.4 Crushed Stone Footings
2018 IRC Transition from the 2012 IRC
2018
R404.4 Retaining WallsR404.4 Retaining Walls Retaining walls > 24 48 in. of unbalanced backfill
designed in accordance with accepted engineering practice (consistent with R404.1.3)
> 24 in. if resisting additional lateral loads Freestanding walls not supported at top Not supporting buildings
2018 IRC Transition from the 2012 IRC
2015 R408.3 Unvented Crawl SpaceR408.3 Unvented Crawl Space
2018 IRC Transition from the 2012 IRC
2018
2018 IRC Update
Copyright 2017 International Code Council 19
FloorsFloors
Chapter 5
Tables R502.3.1(1), R502.3.1(2) Floor Joist Spans for Common Lumber SpeciesTables R502.3.1(1), R502.3.1(2) Floor Joist Spans for Common Lumber Species
Span lengths Decreased for
Southern Pine Increased for DFL and
HF
2 X 10 Floor JoistsDead load = 10 psfLive load = 40 psf16 in. o.c. spacing
2018 IRC Transition from the 2012 IRC
2015
Spans 2012 2015#2 SP 16 - 1 14 - 0#2 DFL 15 - 5 15 - 7#2 HF 15 - 2 15 - 2
#1 SP: 16 – 1 in 2015
R507 DecksR507 Decks
2018 IRC Transition from the 2012 IRC
2018 R507.2, R507.3 Deck MaterialsR507.2, R507.3 Deck Materials
2018 IRC Transition from the 2012 IRC
2018
2018 IRC Update
Copyright 2017 International Code Council 20
R507.3 Deck FootingsR507.3 Deck Footings
2018 IRC Transition from the 2012 IRC
2018R507.4 Deck PostsR507.4 Deck Posts
Deck post size Beam plies Maximum height (ft. – in.)
4 x 4 3 or more 6-94 x 4 1 or 2 84 x 6 86 x 6 148 x 8 14
2018 IRC Transition from the 2012 IRC
2015 & 2018
2018 IRC Transition from the 2012 IRC
2015 & 2018R507.5
Deck Beams
R507.5 Deck Beams
R507.5 Deck BeamsR507.5 Deck Beams
2018 IRC Transition from the 2012 IRC
2018
2018 IRC Update
Copyright 2017 International Code Council 21
R507.6 Deck JoistsR507.6 Deck Joists
2018 IRC Transition from the 2012 IRC
2015 & 2018
R507.6 Deck Joists
R507.6 Deck Joists
2018 IRC Transition from the 2012 IRC
2018
R507.7-R507.9 Decking, Vertical and Lateral Supports
R507.7-R507.9 Decking, Vertical and Lateral Supports
2018 IRC Transition from the 2012 IRC
2015 & 2018 R507.9.2 Alternative Deck Lateral Load ConnectionR507.9.2 Alternative Deck Lateral Load ConnectionOptional Connections Figure 507.2.3(1): Two hold-down
devices ≤ 2 ft of the ends of the deck
Figure 507.2.3(1): Four hold-downs
installed below the deck structure
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Update
Copyright 2017 International Code Council 22
Wall ConstructionWall Construction
Chapter 6
Table R602.3(1) Fastener Schedule for Structural MembersTable R602.3(1) Fastener Schedule for Structural Members
2018 IRC Transition from the 2012 IRC
The fastening schedule now contains multiple nail size options Box and air driven nails
Roof rafter connections at ridge, valley, and hip Double top plate splicing Joist-to-band-joist (rim board) connection
2015
R602.3.1 Alternate Stud HeightsR602.3.1 Alternate Stud Heights
2018 IRC Transition from the 2012 IRC
2015 & 2018 Tables R602.7(1), R602.7(2) Girder and Header Spans
Tables R602.7(1), R602.7(2) Girder and Header Spans
2018 IRC Transition from the 2012 IRC
2015 & 2018
2018 IRC Update
Copyright 2017 International Code Council 23
Tables R602.7(1), R602.7(2) Girder and Header SpansTables R602.7(1), R602.7(2) Girder and Header Spans
2018 IRC Transition from the 2012 IRC
2018
Dropped header with pony wall above
Table R602.7.5 Full Height Studs at End of Headers
Table R602.7.5 Full Height Studs at End of Headers
2018 IRC Transition from the 2012 IRC
2015 & 2018
Wall BracingWall Bracing
2018 IRC Transition from the 2012 IRC
Table R602.10.3 (4) Seismic Adjustment Factors
Table R602.10.3 (4) Seismic Adjustment Factors
2018 IRC Transition from the 2012 IRC
2018
2018 IRC Update
Copyright 2017 International Code Council 24
R602.10.4.1 Mixing Bracing MethodsR602.10.4.1 Mixing Bracing Methods
2018 IRC Transition from the 2012 IRC
2018
3500 lb. strap
2018 IRC Transition from the 2012 IRC
2015
Table R602.10.5 Min. Length BWPsTable R602.10.5 Min. Length BWPsMethod Minimum length (in) Contributing
length (in)Wall height (ft)
8 9 10 11 12PFH – roof only 16 16 16 18 20 48
PFH - story+roof 24 24 24 27 29 48
PFG SDC A, B, C 24 27 30 33 36 1.5 × Actual
CS-PF 16 18 20 22 24 ActualCS-PF SDC A, B, C 16 18 20 22 24 1.5 × Actual
CS-PF SDC D0, D1, D2 16 18 20 22 24 Actual
2018 IRC Transition from the 2012 IRC
2015R602.10.6.2 Method PFHR602.10.6.2 Method PFHPortal Frame with Hold-Downs Recent testing Minimum hold-down capacity
lowered to 3500 lbs Two sill plates are sufficient (3 in
2012 IRC)
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Update
Copyright 2017 International Code Council 25
R602.10.6.4 Method CS-PF—Continuously Sheathed Portal FrameR602.10.6.4 Method CS-PF—Continuously Sheathed Portal Frame
2018 IRC Transition from the 2012 IRC
2018 R602.12Simplified Wall BracingR602.12Simplified Wall Bracing
2018 IRC Transition from the 2012 IRC
3-story buildings (previously 2) Wind Exposure B and C Factor for no. of bracing units for Exp. C: x 1.2 for 1-story x 1.3 for 2-story x 1.4 for 3-story
Wind speed (Vult) 115 and 130 mph (90, 100 Vasd)
2015
Wall CoveringsWall Coverings
Chapter 7
R703.2 Water-resistive BarrierR703.2 Water-resistive Barrier
2018 IRC Transition from the 2012 IRC
1.Per manufacturer
2.Detached accessory buildings
2018
2018 IRC Update
Copyright 2017 International Code Council 26
R703.3 Siding Material Thickness and AttachmentR703.3 Siding Material Thickness and Attachment Replaced Table R703.4, Weather Resistant
Siding Attachment and Minimum Thickness New language clarifies limitations of table and
describes fastener type, length, and penetration. Footnotes to text Columns deleted
2018 IRC Transition from the 2012 IRC
2015 R703.3.1 Soffit InstallationR703.3.1 Soffit Installation
2018 IRC Transition from the 2012 IRC
• And wood structural panels
2018
R703.8.4 Veneer Anchorage Through Insulation
R703.8.4 Veneer Anchorage Through Insulation
2018
2018 IRC Transition from the 2012 IRC
R703.9 Exterior Insulation and Finish SystemsR703.9 Exterior Insulation and Finish Systems Limitations for EIFS EIFS without drainage: Concrete and masonry
EIFS with drainage: All other wall assemblies
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Update
Copyright 2017 International Code Council 27
R703.11.1Vinyl Siding AttachmentR703.11.1Vinyl Siding Attachment Min. 1¼ inches into
“nailable substrate” or Through sheathing per test
report and manufacturer Nail 0.120 shank x 0.313
head 16 in. o.c.
2018 IRC Transition from the 2012 IRC
2015 R703.11.2 Vinyl Siding Installation Over Foam Plastic SheathingR703.11.2 Vinyl Siding Installation Over Foam Plastic Sheathing
2018 IRC Transition from the 2012 IRC
2018
R703.13, R703.14 Insulated Vinyl Siding and Polypropylene SidingR703.13, R703.14 Insulated Vinyl Siding and Polypropylene Siding
Insulated vinyl siding ≥ R-2 Continuous insulation Improved moisture control
Polypropylene siding requires separation: 5 ft. lot lines 10 ft. building on other lot
Fastening requirements
2018 IRC Transition from the 2012 IRC
2015 R703.15, R703.16, R703.17 Cladding Attachment over Foam SheathingR703.15, R703.16, R703.17 Cladding Attachment over Foam Sheathing
To wood framing (R703.15),
To cold-formed steel framing (R703.16), and
To masonry or concrete walls (R703.17).
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Update
Copyright 2017 International Code Council 28
Roof-Ceiling ConstructionRoof-Ceiling Construction
Chapter 8
R802 Roof Framing
R802 Roof Framing
2018 IRC Transition from the 2012 IRC
• Reorganized
2018
R802.1.5.4 FRTW LabelingR802.1.5.4 FRTW Labeling
2018 IRC Transition from the 2012 IRC
2018 Tables R802.4, R802.5 Ceiling Joist and Rafter Span TablesTables R802.4, R802.5 Ceiling Joist and Rafter Span Tables Span lengths Decreased for
Southern Pine Increased for
DFL and HF
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Update
Copyright 2017 International Code Council 29
R806.2 Minimum Vent AreaR806.2 Minimum Vent Area
2018 IRC Transition from the 2012 IRC
• Both conditions to take reduction• Zone 6,7,8 Class I-II vapor retarder• 40-50% within 3 ft. of ridge
2018
Roof AssembliesRoof Assemblies
Chapter 9
R905.1.1UnderlaymentR905.1.1Underlayment
2018 IRC Transition from the 2012 IRC
Underlayment and ice barrier provisions combined for all roofing types
R905.16 Photovoltaic ShinglesR905.16 Photovoltaic Shingles Additional requirements
and limits for photovoltaic shingles
R905.16 Photovoltaic shingles.
R905.16.1 Deck requirements.
R905.16.2 Deck slope. R905.16.3 Underlayment. R905.16.4 Underlayment
application. R905.16.4.1 Ice barrier. R905.16.4.2 Underlayment
and high winds.
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Update
Copyright 2017 International Code Council 30
R905.17 Building Integrated Photovoltaic Panels
R905.17 Building Integrated Photovoltaic Panels
2018 IRC Transition from the 2012 IRC
2018 R907 Rooftop-MountedPhotovoltaic SystemsR907 Rooftop-MountedPhotovoltaic Systems
Requirements and limits for rooftop-mounted photovoltaic systems Wind resistance Fire classification Installation Ref. R324 and NFPA
70Check errata to Section R324 of the 2015 IRC
2018 IRC Transition from the 2012 IRC
2015
2015 ISEPInternational Solar Energy Provisions & Commentary
2018 IRC Transition from the 2012 IRC
Chimneys and FireplacesChimneys and Fireplaces
Chapter 10
2018 IRC Update
Copyright 2017 International Code Council 31
R1005.8 Chimney Insulation ShieldR1005.8 Chimney Insulation Shield
2018 IRC Transition from the 2012 IRC
2018
Energy EfficiencyEnergy Efficiency
Chapter 11
N1101.6, Definition of Air Barrier N1101.6, Definition of Air Barrier
2018
2018 IRC Transition from the 2012 IRC
N1101.6, Definition of Building Thermal EnvelopeN1101.6, Definition of Building Thermal Envelope
2018
2018 IRC Transition from the 2012 IRC
2018 IRC Update
Copyright 2017 International Code Council 32
N1101.6, Tables N1101.10.3(1) and N1101.10.3(2) Fenestration Definitions and U-Factors
N1101.6, Tables N1101.10.3(1) and N1101.10.3(2) Fenestration Definitions and U-Factors
• Clarification• Opaque door
2018
2018 IRC Transition from the 2012 IRC
N1101.13Compliance PathsN1101.13Compliance Paths
1. Sections N1101.14 through N1104.
2. Section N1105 and the provisions of Sections N1101.14 through N1104 labeled “Mandatory.”
3. An energy rating index (ERI) approach in Section N1106.
Projects shall comply with one of the following:
Prescriptive and mandatory provisionsPrescriptive and mandatory provisions
Performance and mandatory provisionsPerformance and mandatory provisions
2018 IRC Transition from the 2012 IRC
2015
N1101.14Permanent Energy CertificateN1101.14Permanent Energy Certificate Inside building:
On wall in furnace space or utility room, or
Another approved location
2018 IRC Transition from the 2012 IRC
2015 N1102.1 Building Thermal Envelope for Log HomesN1102.1 Building Thermal Envelope for Log Homes
2018 IRC Transition from the 2012 IRC
• Blower door test still applies
2018
2018 IRC Update
Copyright 2017 International Code Council 33
Tables N1102.1.2 and N1102.1.4 Insulation and Fenestration Requirements
Tables N1102.1.2 and N1102.1.4 Insulation and Fenestration Requirements
• Lower U-factors
• Zone 3 and above
2018
2018 IRC Transition from the 2012 IRC
Tables N1102.1.2 and N1102.1.4 Prescriptive U-Factors
Tables N1102.1.2 and N1102.1.4 Prescriptive U-Factors
2018
2018 IRC Transition from the 2012 IRC
N1102.1.3 R-Valve Computation- Insulated SidingN1102.1.3 R-Valve Computation- Insulated Siding Insulated siding as
continuous insulation in satisfying wall R-value.
Min R-2 Labeled R-value reduced
by R-0.6 for calculation purposes
2018 IRC Transition from the 2012 IRC
2015 N1102.2.2 Reduction of Ceiling InsulationN1102.2.2 Reduction of Ceiling Insulation
2018 IRC Transition from the 2012 IRC
2018
2018 IRC Update
Copyright 2017 International Code Council 34
N1102.2.4 Access Hatches and DoorsN1102.2.4 Access Hatches and Doors Vertical doors that
access unconditioned attics and crawl spaces: Do not require an R-
value to match the required wall insulation.
Must comply with the fenestration U-factor requirements of Table N1102.1.2.
2018 IRC Transition from the 2012 IRC
2015N1102.2.5 Mass WallsN1102.2.5 Mass Walls
2018
2018 IRC Transition from the 2012 IRC
N1102.2.8, Table N1102.4.1.1 Floor Framing Cavity InsulationN1102.2.8, Table N1102.4.1.1 Floor Framing Cavity Insulation Permits air space
above floor framing cavity insulation
Table N1102.4.1.1 reformatted into three columns to separate air barrier from insulation requirements.
2018 IRC Transition from the 2012 IRC
2015
• RESNET/ICC 380
2018
2018 IRC Transition from the 2012 IRC
2018 IRC Update
Copyright 2017 International Code Council 35
N1103.3 Duct Sealing and TestingN1103.3 Duct Sealing and Testing Duct sealing and testing reorganized Maximum duct leakage rates now prescriptive for
flexibility If not part of the heating or
cooling system ductwork, ducts serving HRV or ERV do not require air test
2018 IRC Transition from the 2012 IRC
2015 & 2018 N1103.5 Heated Water Circulation and Temperature Maintenance SystemsN1103.5 Heated Water Circulation and Temperature Maintenance Systems
Automatic controls Continuously operating circulation pumps are
no longer permitted. Heat trace systems must comply with one of
the referenced standards.
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Transition from the 2012 IRC
2018N1104.1 LightingN1104.1 Lighting
2018
2018 IRC Transition from the 2012 IRC
2018 IRC Update
Copyright 2017 International Code Council 36
N1106.3, N1106.4 Maximum Energy Rating IndexN1106.3, N1106.4 Maximum Energy Rating Index
2018 IRC Transition from the 2012 IRC
2018
MechanicalMechanical
Chapters 12 through 23
M1305.1.1 Access to Furnaces within CompartmentsM1305.1.1 Access to Furnaces within Compartments
2018
2018 IRC Transition from the 2012 IRC
M1305.1.3.2 Appliances Installed in PitsM1305.1.3.2 Appliances Installed in Pits
2018 IRC Transition from the 2012 IRC
2018
2018 IRC Update
Copyright 2017 International Code Council 37
M1502.3.1 Dryer Exhaust Duct TerminationM1502.3.1 Dryer Exhaust Duct Termination
2018 IRC Transition from the 2012 IRC
2018
• 12.5 sq. in.
M1502.4.2 Concealed Dryer Exhaust DuctsM1502.4.2 Concealed Dryer Exhaust Ducts
2018 IRC Transition from the 2012 IRC
2018
M1502.4.4, M1502.4.5 Dryer Exhaust Duct Power Ventilators M1502.4.4, M1502.4.5 Dryer Exhaust Duct Power Ventilators Dryer exhaust duct power
ventilators (DEDPVs) Listed and labeled UL
705 Max. length per
manufacturer
2018 IRC Transition from the 2012 IRC
2015 M1502.4.6Dryer Duct Length IdentificationM1502.4.6Dryer Duct Length Identification Permanent label where
>35 feet Not required where ≤ 35
feet Whether the duct is
concealed or not
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Update
Copyright 2017 International Code Council 38
M1503.6 Makeup Air for Kitchen Exhaust SystemsM1503.6 Makeup Air for Kitchen Exhaust Systems Makeup air for kitchen
exhaust systems >400 cfm: Automatic damper, or Gravity damper Transfer openings okay
2015
2018 IRC Transition from the 2012 IRC
M1503.6 Makeup Air for Kitchen Exhaust SystemsM1503.6 Makeup Air for Kitchen Exhaust Systems
2018
• Not required if all direct vent or mechanical draft vent• Domestic cooking exhaust
2018 IRC Transition from the 2012 IRC
M1506.2 Exhaust Duct LengthM1506.2 Exhaust Duct Length Maximum exhaust duct lengths based on: Duct diameter Type of duct Exhaust fan airflow rating
2018 IRC Transition from the 2012 IRC
2015 M1601.1.2 Underground Duct SystemsM1601.1.2 Underground Duct Systems
2018 IRC Transition from the 2012 IRC
2018
2018 IRC Update
Copyright 2017 International Code Council 39
M1601.4 Duct InstallationM1601.4 Duct Installation Tapes and mastics for sheet metal ducts listed to
UL 181 B Snap-lock and button-lock seams no longer
exempt from the sealing
2018 IRC Transition from the 2012 IRC
2015 M2101.10 Pressure Tests for Hydronic PipingM2101.10 Pressure Tests for Hydronic Piping
2018
2018 IRC Transition from the 2012 IRC
M2103.2 Thermal Barrier for Radiant Floor Heating Systems
M2103.2 Thermal Barrier for Radiant Floor Heating Systems
2018 IRC Transition from the 2012 IRC
2018
Fuel GasFuel Gas
Chapter 24
2018 IRC Update
Copyright 2017 International Code Council 40
G2404.11 Condensate PumpsG2404.11 Condensate Pumps Condensate pumps Uninhabitable spaces Shut down equipment if pump fails
2018 IRC Transition from the 2012 IRC
2015 G2406.2 Prohibited Locations for AppliancesG2406.2 Prohibited Locations for Appliances
2018
2018 IRC Transition from the 2012 IRC
G2411.2 Electrical Bonding of Corrugated Stainless Steel TubingG2411.2 Electrical Bonding of Corrugated Stainless Steel Tubing
75-foot maximum allowable length of bonding jumper
Bonding methods must comply with NFPA 70
Devices, such as clamps, must be listed in accordance with UL 467
2018 IRC Transition from the 2012 IRC
2015 G2411.2, G2411.3 Electrical Bonding of CSSTG2411.2, G2411.3 Electrical Bonding of CSST
2018 IRC Transition from the 2012 IRC
2018
2018 IRC Update
Copyright 2017 International Code Council 41
G2413.2 Maximum Gas DemandG2413.2 Maximum Gas Demand Table G2413.2 Approximate
Input and the reference to it were deleted
The code requires the actual maximum input rating of the appliances to be known and used for gas pipe sizing purposes.
2018 IRC Transition from the 2012 IRC
2015 G2414.4.2, G2414.10.1 Schedule 10 Steel Gas Piping
G2414.4.2, G2414.10.1 Schedule 10 Steel Gas Piping
2018
2018 IRC Transition from the 2012 IRC
G2414.6Plastic Pipe, Tubing and FittingG2414.6Plastic Pipe, Tubing and Fitting PVC and CPVC pipe are expressly prohibited
materials for supplying fuel gas.
2018 IRC Transition from the 2012 IRC
2015 G2415.7 Protection of Concealed Piping Against Physical DamageG2415.7 Protection of Concealed Piping Against Physical Damage Rewritten to address
concealed piping: Parallel to framing
members Within framing members
Protection must extend 4 inches beyond edge of members that are bored or notched
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Update
Copyright 2017 International Code Council 42
G2415.11 Protection Against CorrosionG2415.11 Protection Against Corrosion
2018
2018 IRC Transition from the 2012 IRC
G2420.5.1 Shutoff Valve LocationG2420.5.1 Shutoff Valve Location
2018 IRC Transition from the 2012 IRC
2018
G2420.6 Support for Shutoff Valves in Tubing Systems
G2420.6 Support for Shutoff Valves in Tubing Systems
2018
2018 IRC Transition from the 2012 IRC
G2421.2 Medium-Pressure RegulatorsG2421.2 Medium-Pressure Regulators Medium-Pressure (MP) line regulators installed
in rigid piping must have a union installed to allow removal of the regulator.
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Update
Copyright 2017 International Code Council 43
G2426.7.1 Door Clearance to Vent TerminalsG2426.7.1 Door Clearance to Vent Terminals An appliance vent
terminal is not permitted in a location with 12 inches of the arc of a swinging door.
2018 IRC Transition from the 2012 IRC
2015 G2427.8 Venting System Termination LocationG2427.8 Venting System Termination Location 10-foot separation where vent discharges in the
direction of an opening in an adjacent building.
2018 IRC Transition from the 2012 IRC
2015
G2439.4, G2439.7 Clothes Dryer Exhaust DuctsG2439.4, G2439.7 Clothes Dryer Exhaust Ducts Dryer exhaust duct power ventilators (DEDPVs)
UL 705 per manufacturer
Permanent label: Duct length
>35 feet Duct
concealed or not
Duct fasteners permitted
2018 IRC Transition from the 2012 IRC
2015 G2442.2 Forced Air Furnace Duct SizeG2442.2 Forced Air Furnace Duct Size
2018 IRC Transition from the 2012 IRC
2018
2018 IRC Update
Copyright 2017 International Code Council 44
G2447.2 Commercial Cooking AppliancesG2447.2 Commercial Cooking Appliances
2018 IRC Transition from the 2012 IRC
2018
PlumbingPlumbing
Chapters 25 through 33
P2502.1, P2503.4 Inspection and Tests for Building SewersP2502.1, P2503.4 Inspection and Tests for Building Sewers When the entire sanitary drainage system is replaced: Internal examination of underground and under slab
piping is required toverify: Size Slope Condition
2018 IRC Transition from the 2012 IRC
2015 P2503.5 Drain, Waste, and Vent Systems TestingP2503.5 Drain, Waste, and Vent Systems Testing
The head pressure for a water test on DWVsystems has been reduced from 10 feet to 5 feet.
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Update
Copyright 2017 International Code Council 45
P2503.7 Air Testing of PEX PipingP2503.7 Air Testing of PEX Piping
2018
2018 IRC Transition from the 2012 IRC
P2602.1 Connections to Public Sewer or Private Sewage Disposal System
P2602.1 Connections to Public Sewer or Private Sewage Disposal System
2018
2018 IRC Transition from the 2012 IRC
P2603.2.1 Protection Against Physical DamageP2603.2.1 Protection Against Physical Damage
Edge distance reduced from <1½ in. to <1¼ in.
Accommodates ½-in. dia. copper pipe in 2x4 framing
2018 IRC Transition from the 2012 IRC
2015 P2702.1, P2706.1Waste ReceptorsP2702.1, P2706.1Waste Receptors
A definition of waste receptor has been added to the code.
Waste receptors are now permitted in bathrooms and closets.
WASTE RECEPTOR. A floor sink, standpipe, hub drain or a floor drain that receives the discharge of one or more indirect waste pipes.
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Update
Copyright 2017 International Code Council 46
P2704 Slip Joint ConnectionsP2704 Slip Joint Connections
2018
2018 IRC Transition from the 2012 IRC
P2713.1 Bathtub OverflowP2713.1 Bathtub Overflow
2018 IRC Transition from the 2012 IRC
2018
P2717Dishwashing MachinesP2717Dishwashing Machines References applicable standards for integral air gaps “food waste disposer” replaces “food waste grinder.” One or two compartment sink Sections P2717.2 and P2717.3 regarding dishwasher
discharge to the sink tailpiece or the food waste disposer combined into a single Section P2717.2.
Discharge loop to underside of counter “fastened” or “held in place.”
2018 IRC Transition from the 2012 IRC
2015 P2801 Water Heater Drain Valves and PansP2801 Water Heater Drain Valves and Pans Requires drain valves with
a threaded outlet Aluminum and plastic
pans of the prescribed thickness acceptable.
Pan drain is not required when a water heater is replaced and there is no existing drain.
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Update
Copyright 2017 International Code Council 47
Pho
to c
ourte
sy o
f Low
e's
P2801.6 Plastic Pan for Gas-Fired Water Heaters
P2801.6 Plastic Pan for Gas-Fired Water Heaters
2018
2018 IRC Transition from the 2012 IRC
P2804.6.1 Water Heater Relief Valve Discharge PipingP2804.6.1 Water Heater Relief Valve Discharge Piping The T&P relief valve
discharge pipe termination requires an air gap
PEX and PE-RT tubing: One size larger than the T&P
valve discharge outlet Outlet end fastened in place
2018 IRC Transition from the 2012 IRC
2015
P2901, P2910 through P2913 Nonpotable Water SystemsP2901, P2910 through P2913 Nonpotable Water Systems Nonpotable water outlets
identified Purple identifies distribution
piping for nonpotable water New Sections P2910 through
P2913: Collection Storage Distribution
2018 IRC Transition from the 2012 IRC
2015 P2902.5.4, P2904 Backflow Protection for Fire Sprinkler Systems
P2902.5.4, P2904 Backflow Protection for Fire Sprinkler Systems
2018
2018 IRC Transition from the 2012 IRC
2018 IRC Update
Copyright 2017 International Code Council 48
P2903.5 Water Hammer ArrestorsP2903.5 Water Hammer Arrestors
2018 IRC Transition from the 2012 IRC
2018 P2906.2 Lead Content of Drinking Water Pipe and FittingsP2906.2 Lead Content of Drinking Water Pipe and Fittings Water for drinking or
cooking Piping, fittings, joints: ≤0.25% lead content Federal law NSF 372
Other water supply piping: ≤8% lead content NSF 61
2018 IRC Transition from the 2012 IRC
2015
P2906.6.1 Saddle Tap Fittings on Water Distribution PipingP2906.6.1 Saddle Tap Fittings on Water Distribution Piping
2018 IRC Transition from the 2012 IRC
2018 P2906.18.2 Joints Between PVC and CPVC Water Piping
P2906.18.2 Joints Between PVC and CPVC Water Piping
2018 IRC Transition from the 2012 IRC
2018
2018 IRC Update
Copyright 2017 International Code Council 49
P3003.2 Prohibited Joints (Single PVC to ABS fitting)P3003.2 Prohibited Joints (Single PVC to ABS fitting)
2018
2018 IRC Transition from the 2012 IRC
P3003.9 Solvent Cementing of PVC JointsP3003.9 Solvent Cementing of PVC Joints Primer not required for: DWV PVC pipe and fittings ≤ 4-inch pipe size Non-pressure application
2018 IRC Transition from the 2012 IRC
2015
P3005.1.6 Reduction in Pipe SizeP3005.1.6 Reduction in Pipe Size
2018 IRC Transition from the 2012 IRC
2018 P3005.2 CleanoutsP3005.2 Cleanouts Section completely
reorganized Brass cleanout plugs only for
metallic piping Cleanout ≤ 1½ inches of
finished wall surface No longer required at base of
each waste or soil stack
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Update
Copyright 2017 International Code Council 50
P3008.1 Backwater ValvesP3008.1 Backwater Valves Existing buildings: Fixtures above next
upstream manhole cover: Allowed to discharge
through backwater valve
2018 IRC Transition from the 2012 IRC
2015
2018 IRC Transition from the 2012 IRC
2015
• Frost closure:• 3-inch pipe transition 12 in.
inside thermal envelope. • ≥ 7-foot height applies to roofs
for purposes similar to residential decks, patios and balconies.
P3103.1, P3103.2 Vent TerminalsP3103.1, P3103.2 Vent Terminals
P3103.1 Vent Pipe TerminationsP3103.1 Vent Pipe Terminations
2018
2018 IRC Transition from the 2012 IRC
P3111 Combination Waste and Vent SystemP3111 Combination Waste and Vent System
2018 IRC Transition from the 2012 IRC
2018
2018 IRC Update
Copyright 2017 International Code Council 51
P3114.8 Prohibited Installations for Air Admittance Valves
P3114.8 Prohibited Installations for Air Admittance Valves
2018 IRC Transition from the 2012 IRC
2018 P3201.2 Trap Seal Protection Against EvaporationP3201.2 Trap Seal Protection Against Evaporation Trap seal protection
against evaporation can now be accomplished in a variety of ways, including trap seal primer valves supplied with nonpotable water and barrier-type trap seal protection devices
2018 IRC Transition from the 2012 IRC
2015
ElectricalElectrical
Chapters 34 through 43
E3703.5 Garage Branch CircuitsE3703.5 Garage Branch Circuits
2015 & 2018
2018 IRC Transition from the 2012 IRC
2018 IRC Update
Copyright 2017 International Code Council 52
E3901.2 Wall Space for Receptacle DistributionE3901.2 Wall Space for Receptacle Distribution
2018
2018 IRC Transition from the 2012 IRC
E3901.3 Appliances on 15 Amp Circuits
E3901.3 Appliances on 15 Amp Circuits
2018 IRC Transition from the 2012 IRC
2018
E3901.9 Garage Receptacle Outlet LocationE3901.9 Garage Receptacle Outlet Location
2018 IRC Transition from the 2012 IRC
2015 & 2018
E3902.4 GFCI Protection for Crawl Space Lighting Outlets
E3902.4 GFCI Protection for Crawl Space Lighting Outlets
2018 IRC Transition from the 2012 IRC
2018
2018 IRC Update
Copyright 2017 International Code Council 53
E3902.8, E3902.9, E3902.10 Ground-Fault Circuit Interrupter Protection
E3902.8, E3902.9, E3902.10 Ground-Fault Circuit Interrupter Protection Laundry areas Receptacles within 6 feet
of bathtubs and showers Receptacles for
dishwashers
2018 IRC Transition from the 2012 IRC
2015 E3905.2.1 Nonmetallic-Sheathed Cable and Metal Boxes
E3905.2.1 Nonmetallic-Sheathed Cable and Metal Boxes
2018 IRC Transition from the 2012 IRC
2018
E4101.3 Cord- and-Plug-Connected AppliancesE4101.3 Cord- and-Plug-Connected Appliances
2018
2018 IRC Transition from the 2012 IRC
Table E4101.3Table E4101.3
2018 IRC Transition from the 2012 IRC
2018
2018 IRC Update
Copyright 2017 International Code Council 54
AppendicesAppendices
Appendix Chapters Q, R, S
Appendix Q Tiny HousesAppendix Q Tiny Houses
2018 IRC Transition from the 2012 IRC
2018
Appendix R Light straw-clay construction
Appendix R Light straw-clay construction
2018 IRC Transition from the 2012 IRC
2015 & 2018
Appendix S Strawbale constructionAppendix S Strawbale construction
2018 IRC Transition from the 2012 IRC
2015 & 2018
2018 IRC Update
Copyright 2017 International Code Council 55
2018 IRC Transition from the 2012 IRC
Discussion ActivityDiscussion Activity Final ReflectionFinal Reflection
This slide will help the learner to reflect on the day and what they will take back to the job and apply. What? What happened and what was observed
in the training? So what? What did you learn? What difference
did this training make? Now what? How will you do things differently
back on the job as a result of this training?
2018 IRC Transition from the 2012 IRC
International Code Council is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will be reported to CES Records for AIA members. Certificates of Completion for non-AIA members are available on request.
This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any material of construction or any method or manner of handling, using, distributing, or dealing in any material or product. Questions related to specific materials, methods, and services will be addressed at the conclusion of this presentation.
Copyright Materials
This presentation is protected by US and International Copyright laws. Reproduction, distribution, display and use of the presentation without written permission of the speaker is
prohibited.
© International Code Council 2017
2018 IRC Update
Copyright 2017 International Code Council 56