3Corning Cable Systems
������������ �� �� ����� ����� ����� �������
With over 150 years of experience in theworld of telecommunications, Corning is anexperienced partner you can trust to bringcost-effective solutions to your communi-cation requirements. In the field of fiber opticcable technology, Corning was one of theoriginal pioneers with expertise second tonone.
As early as 1974, when fiber optic technologywas still in its infancy, Corning was workingwith Europe’s leading Public Tele-communications companies in developingtrial fiber optic cable routes. This wascomplemented in 1979 by additional projectsin the USA. Together this pioneering workmarked the start of the global business which exists today, comprising of a wide range ofdemanding customer projects.
We at Corning offer the broadest range of end-to-end copper and fiber optic product solutions forcustomers’ cabling network.As system leaders we provide products not only as individual items but also as complete cablenetworks from a single source. Our global presence is your gain because, wherever you arelocated, Corning is close at hand.
Our quality and environmental management systems are naturally certified to DIN EN ISO 9001and ISO 14001.
4 Corning Cable Systems
Our commitment is to meet the expectationsof our customers unreservedly in supplyinghigh-quality products and services for allcommunication networks.
�� ������ ����������������
5Corning Cable Systems
12
3 54
6
7
8
9 10
A
11
125
B1
23
4
6
7
8
9
10
12
13
11
����������� ���� ��� ��������� ���!���"�� #���� ��
Headquarters Europe, Asia/Pacific, AfricaMunich, Germany
Nordenham, GermanyHagen, GermanyNeustadt, GermanyBerlin, Germany
Favières, France
Turin, ItalyRoseto degli Abruzzi, Italy
Inofitas, Greece
Gebze, Turkey
Chengdu, China
Ho Chi Minh City, Vietnam
Ramadan City, Egypt
Kuala Lumpur, Malaysia
Jakarta, Indonesia
Clayton, Australia
Derby, GBWarrington, GBWhiston, GBHemel Hempstead, GBAberdeen, GB
Madrid, Spain
1
B
2
3
4
5
6
7
8
9
10
11
12
13
HeadquartersNorth-, South-America/JapanHickory, NC, USA
Saskatoon, Canada
Montreal, Canada
Winston-Salem, NC, USA
Keller, TX, USA
Kernersville, NC, USA
Reynosa, Mexico
Mexico City, Mexico
Boca Raton, FL, USA
Santo Domingo, Dominican Republic
Rio Grande, Puerto Rico
Buenos Aires, Argentina
Tokyo, Japan
1
A
2
3
4
5
6
7
8
9
10
11
12
6 Corning Cable Systems
���� ��
���������������� ������������������
Introduction ..........................................................................................................................................................10Overview on Closures ..........................................................................................................................................12
Mechanical Closures for Pressurized Primary NetworksInline Closure UCN ...............................................................................................................................................16Vault Cable Closure UCNV ...................................................................................................................................22Tool Case for Installation of UCN Closures ...........................................................................................................26Inline Closure MHS P ...........................................................................................................................................28
Mechanical Closures for Secondary NetworksInline Closure UCA ...............................................................................................................................................32Inline Closure MHS M ..........................................................................................................................................34Distribution Closure BPR......................................................................................................................................40Aerial Closure PEV ..............................................................................................................................................44Temporary Splice Protection Closure MEP ...........................................................................................................46
Heat-shrinkable Closures for Pressurized Primary NetworksReinforced Inline Closures GSC CP .....................................................................................................................47
Heat-shrinkable Closures for Secondary NetworksReinforced Inline Closures GSC, GSC C ..............................................................................................................47Standard Inline Closures SCX, SCX C .................................................................................................................54
Repair SleevesWrap-around Repair Sleeves SCX R (Standard), GSC R (Reinforced) ..................................................................59
Gas Torch Set ......................................................................................................................................................61
�����������
Corning Product Range for Copper Communication Networks ............................................................................... 8
7Corning Cable Systems
�����������������������������������������������
Connection and Distribution System 1001/2001 SeriesIntroduction ..........................................................................................................................................................64Disconnection, Switch and Connection Strips ......................................................................................................65Grounding and Dropwire Connection Strip ............................................................................................................67Overvoltage / Overcurrent Protection ...................................................................................................................68Plugs, Marking Caps, Cords ................................................................................................................................70Tools ....................................................................................................................................................................71Mounting Frames, Cable Terminal Heads ..............................................................................................................72Label Frames, Strip Dimensions ...........................................................................................................................73Technical Data .....................................................................................................................................................74
Cabinets and BoxesCross-Connection Cabinet KVz ............................................................................................................................75Wall-Mounted Distribution Enclosures / Boxes for 1001/2001 Series ....................................................................76Accessories for Distribution Enclosures / Boxes ..................................................................................................78
���� ��
Note:The products shown in this catalog demonstrate some of the additional accessories availablewhich are not part of the standard scope of delivery
�������������������
Training ................................................................................................................................................................82Contacts ..............................................................................................................................................................83Other Catalogs Available in our Product Range ....................................................................................................88
8 Corning Cable Systems
������������������ ������� ��������������$ �"��%������������
The Corning product range provides all maincomponents necessary for connection and distributionof copper cables in communication networks. Corningoffers a „tip to tip“ product range from the central officeto the subscriber - all out of one hand.
Our product range comprises:
For the central officeand big private switches:• Connection and distribution systems MDF. See
catalog „Connection and Distribution Systems“.• Distribution closures UCNV for the transition of the
main cable to distribution cables
For the cable line:Joint and branching closures / repair sleeves:• Mechanical inline closures UCN and MHS P for
pressurized main cables• Mechanical inline closures UCA, MHS M and MEP
for non-pressurized branching and distribution cables• Mechanical distribution closure BPR for subscriber
cables
• Heat-shrinkable inline closures GSC CP forpressurized main cables
• Mechanical free-breathing inline closures PEV foraerial cables
• Heat-shrinkable repair sleeves GSC R / SCX Rfor all non-pressurized cables
Distribution components:• Disconnection, connection and switching strips
1001/2001 Series• Overvoltage- / overcurrent protection
1001/2001 Series• Cable distribution cabinet for accommodating
termination heads at switching and distributionpoints
• Termination heads for installation in cabledistribution cabinets
For buildings:• Wall distribution cabinets for 1001/2001 Series,
outdoor and indoor
DB
CCC
CCC
UCN, MHS PGSC CP
DB
UCN, MHS PGSC CP
CCC
UCN / MHS PGSC CP
PEV
PEV UCA / MHSMGSC / SCX
GSCSCX
MDF
HVT
UCNV
UCN, MHS PGSC CP
Homes
MDF = Main Distribution FrameCCC = Cross-Connection CabinetDB = Distribution Box
UCN, MHS P, UCA,UCNV, MHSE, PEV,GSC, SCX = Closures
Central OfficeCentral Office
Remote Terminal
Large BusinessCustomers
Apartmentcomplex
UCA / MHSM / BPRGSC / SCX
9Corning Cable Systems
���������������� ������������������
10 Corning Cable Systems
����������������������� ��� �����������
�����������
General
With the world’s largest range of closures, Corningoffers a complete line of solutions for connecting anddistributing all types of communication cable.
Closures are used to provide protection for splices onstraight, branching and distribution cables. Themechanical and electrical continuity provided by theclosures must be as though there had been no breakin the cables at this point.
This requirement applies regardless of the
• location of the cables, e.g. buried directly in theground, installed in ducts or on aerial cable routes
• type of cable, e.g. pressurized or grease filled
• design of the cable, e.g. with laminated sheath orarmoring.
The mechanical continuity is achieved by strain-relieving (anchoring) the cable sheaths.The electrical continuity of any armoring or metallicfoils in laminated sheaths is provided by a high-quality,low-resistance bond to ground bonding lines.It is provided to protect the installers and the electronicequipment from possible overvoltages which thesecable elements may develop from external sourcesand then discharge. In addition these bonds can bejoined to external grounding points.
The Closure Range
Closures are generally classified according to theirdesign into mechanical and heat-shrink types.
Mechanical closures comprise rigid closure tubes ordomes with one or two end caps for the cable en-trances. The sealing between the closure componentsthemselves and to the cables is made by means ofplastic compounds such as sealing tapes or gels or bysilicone seals. Pressure is applied to the seals me-chanically, i.e. with clips, hooks or screw fasteners.
Mechanical closures can be re-entered and closed asrequired for maintenance or system expansionpurposes.
The main product of this type offered by Corning is therange of Universal Closures UCN, designed speciallyfor the pressurized primary cable network and henceto withstand maximum stressing.There are also various solutions available for the non-pressurized secondary network, e. g. within the MHSrange.
Heat-shrink closures comprise heat-shrinkablesleeves which are wrapped around the splice and thecable ends. The closure is shrunk down using a gastorch to contract uniformly around the splice and thecable ends. An adhesive coating, also thermallyactivated, on the inside of the sleeve ensures aneffective seal.
There are different types of heat-shrink closureavailable for both the pressurized primary network andnon-pressurized secondary network.
11Corning Cable Systems
Aerial network Cable in ducts / manhole Direct buried network
Butt ConfigurationAll cables are fed into the closure on one side only.
Aerial network Cable in manhole / hand-hole
Closure Design
Straight or Inline Closure ConfigurationIncoming and outgoing cables on both sides of the closure.
����������������������� ��� �����������
�����������
12 Corning Cable Systems
����������������������� ��� �����������
����� ������������
Mechanical Closures
Heat-shrinkable Closures
UCN UCNV MHS P
UCA MHS M BPR
PEV MEP
GSC CP, GSC C, GSC SCX
13Corning Cable Systems
*
����������������������� ��� �����������
����� ������������
UCN
UCA
MHS
M
mechanical
heat-shrinkable
pressurized
non-pressurized
aerial
duct / manhole
buried
straight
butt
main
distribution
high
medium
low
Cable
ClosureApplication
ClosureType
See page 16 22 28 32 34 40 44 46 47 47 54
Cable SealingVersion
✔ ✔✔
✔✔
✔ ✔
✔
✔✔
✔ ✔
✔
✔
✔
✔
✔
✔✔ ✔✔
✔
✔
✔ ✔ ✔✔
✔✔ ✔
✔
✔
✔Splice Capacity
Temporary Application
UCNV
GSC
/ C
SCX
/ C
GSC
CP
ClosureConfiguration
X X X XX
X XX
✔✔✔ ✔
✔✔✔
✔✔
✔ ✔ ✔ ✔ ✔✔
✔✔ ✔*✔ ✔
✔✔ ✔ ✔✔
✔ ✔ ✔ ✔ ✔ ✔
Special application: Connection of trunk cables with cables to the MDF inside central offices
Cable sealing version
Main application
Possible but not main application
Not possible
✔
BPR
Network Level
✔
✔
X
✔
✔
✔
✔
✔
✔
X
✔
✔
✔
✔
✔
PEV
MEP
MHS
P
✔
✔
✔
✔
✔
✔
✔
X
✔
✔
*✔
X
14 Corning Cable Systems
����������������������� ��� �����������
������������������
General
Corning offers a complete range of mechanicalclosures for all applications in the copper telecommu-nication network. The core product of this range is theUniversal Closure UCN, the mechanical closure mostwidely used in the world. More than eight million UCNare in service in pressurized and non-pressurizednetworks.
The UCN is designed as an inline closure withincoming cable(s) on one side and outgoing cable(s)on the other side (straight joint).
A modified UCN called UCNC is available as a buttclosure with canister and one end cap whichaccommodates all cables fed in on the same side.
Another special application of the UCN is the UCNV(UCN vault closure) which is used in exchange officesfor connection of the trunk cable to the MDF cables.
Further Closure Types
As completion of the UCN range, further closure typesare available:
• Type MHS P for pressurized and non-pressurizedhigh-pair cables
• Types UCA, MHS M and BPR for non-pressurizedlow- and medium-pair cables
• Type PEV (free-breathing) for use on non-pressurized aerial cables
• Type MEP for temporary non-pressurizedapplications
Mechanical closure UCN
Features
• Access to splice area as often as required without theneed of spare parts and consumables
• High-quality sealing material guarantees watertightencapsulation of the splice area
• Closure housings made of plastic which withstandhigh mechanical load
• Easy and fast installation without additional energye.g. gas or electricity
• Re-opening and re-closing of the closure verysimple to handle
• Reliable strain relief systems integrated in end caps• No harmful substances are used• Designed for at least 30 years lifetime
The special features of the different types aredescribed on pages 16 to 46.
15Corning Cable Systems
����������������������� ��� �����������
�����������������������������������������
Application
Heat-shrinkable Closures
Heat-shrinkable closures are used in communicationcable networks, particularly in the distribution network,as inline closures for protecting and sealing the spliceareas of copper cables. They can be used on cut anduncut cables for straight and branch splices. Up to 4cables can be led into each side of the closure.
The following series of closures are available for non-pressurized cable networks:
• Reinforced closure GSC, GSC C• Standard closure SCX, SCX C
For pressurized cable networks Corning supplies thereinforced closure
• GSC CP with tightness testing valve.
Repair Sleeves
Used for repairing of damaged cable sheaths.
• Reinforced repair sleeve GSC R• Standard repair sleeve SCX R
All RXS closure types and repair sleeves are suitablefor direct buried installation and aerial application.
Features
• High mechanical strength• Reliable sealing of the splice itself and of the sleeve
to the cable sheath against moisture with hot meltadhesive
• Simple installation, only gas torch for installationrequired (torch set see page 61)
• Only a few different sizes required for all cablediameters
• Designed for at least 30 years lifetime• No harmful substances are released during
processing
The special features of the different heat-shrinkableclosures are described on pages 47 to 60.
Heat-shrinkable closures GSC CP, GSC C, GSC
16 Corning Cable Systems
Application
Universal Closures UCN are designed to protectstraight or branch splices on high pair count coppercables against environmental influences. The closurescan be installed on cut or uncut cables and aresuitable for direct buried, aerial and undergroundinstallation. They are suitable for pressurized and non-pressurized cables.
Special Features
• Large variety for all cable types, splice configu-rations and connectors
• Individual adaptation of the cable entries on site bydrilling the end caps according to number of cablesand their diameters
• Quick re-opening and re-closing of the closure tubewithout the need of special tools
• Re-usable closure sealings• No outside metal parts mean no danger of corrosion• Strain relief system integrated in the end caps
��� ����������������������
Design
The Universal Closure UCN consists of two plastic endcaps and a plastic closure tube. The two-section endcaps incorporate the strain relief that absorbs the me-chanical forces which may be applied to the cables.Three-piece end caps are available to accommodate ahigher number of cables.Two metal bars interconnect the two end caps. On-sitehand-drilling of the cable entries provides flexibilitywith regard to cable diameter, number and arrange-ment of the cables.During installation of the end caps, the strain-reliefdisks are automatically pressed by two aluminum col-lars onto the cables. The compression guaranteesexcellent resistance against push and pull.The longitudinally split closure tube is closed with twoplastic bars. They are pushed on by a hammer andare secured with pins.Permanently elastic longitudinal and round sealingsallow the closure to be opened and re-closed as oftenas required without the need of consumables. EachUCN is equipped with test valve and externalgrounding device.
UCN: Easy installation with clamping bars
17Corning Cable Systems
��� �������������
�����������������������
Kit Content
Each closure package contains all parts required forthe installation of a branch closure with up to 4 cables.The pre-cut sealing rings of the end caps with thejoiner element allow installation of UCN closures oncut as well as on uncut cables respectively onrehabilitation of existing splices.
1 Closure tube2 Splice protection3 End caps4 Connection bar5 Sealing tape6 Sealing rings (M-profile with joiner clips)7 Longitudinal sealing8 Installation instructions9 Clamping bars
10 Lubricant11 Gauge12 Measuring tape13 Brush14 Sealing paste15 Cable shield connection clips16 Cleaning tissues17 Cable sheath connection lead18 Branching cable shield connection leads19 Valve protection cap20 Grounding screws
Installation
Detailed installation instructions are enclosed in eachclosure pack. Installation requires a "Tool Case forInstallation of Universal Closures UCN" which has tobe ordered separately (see page 26).
1
2
3
3
45
67
8 9
10
11
12
13
14 15
16
1718
19 20
18 Corning Cable Systems
��� ����������������������� �������!���"�#����
Oval end cap (UCN)
Three-section end cap (UCNT)
Two-section end cap (UCN) Two-section A B C SEnd Cap [mm] [mm] [mm] [mm]
UCN 5-... 46 53 46 10
UCN 7-... 64 105 64 10
UCN 9-... 100 145 80 10
UCN 11-... 104 205 104 10
Oval A B SEnd Cap [mm] [mm] [mm]
UCN 7-... 64 125 10
UCN 9-... 88 186 10
S
A C
B
S
A
B
A B
E D
SC
1
1 and 2 = Cutting levelS
Three-section A B C D E SEnd Cap mm mm mm mm mm mm
UCNT 9-... 66 44 105 52 24 10
UCNT 11-... 100 55 150 80 30 10
19Corning Cable Systems
��� �������������
����������������������������
Closure Type Capacity in Pairs Capacity in Pairs DesiccantModular-splice (25 Pairs) Single Splice, (to be
or AMP-TEL-Splice or orderedAMP-Mini-PICABOND Splice Scotchlok Connector Splice separately)
Conductor Diameter [mm] Conductor Diameter [mm]0.4 0.5 0.6 0.9 0.4 0.5 0.6 0.9 [g]
UCN 5-10 200 150 100 80 180 150 120 80 100UCN 5-20 350 300 250 100 300 250 200 100 150
UCN 7-9 oval 700 600 500 250 600 500 400 200 150UCN 7-10 800 700 600 300 700 600 500 250 150UCN 7-15 1000 800 600 350 900 800 500 275 150UCN 7-20 1200 800 600 400 1100 900 600 300 200UCN 7-30 1800 1200 900 500 1600 1200 900 400 250
UCN 9-20 2400 2100 1200 600 2100 1900 1100 500 250UCN 9-20 oval 2800 2500 1600 800 2500 2200 1600 650 350UCN 9-24 2700 2400 1500 700 2400 2100 1500 600 300UCN 9-28 3100 2700 1800 750 2700 2300 1700 700 350UCN 9-30 3300 2800 2000 900 3000 2400 1800 800 350
UCN 11-20 3200 2700 1800 800 3000 2400 1500 700 400UCN 11-30 4800 4000 2700 1000 4400 3000 2000 900 450UCN 11-40 6000 5200 3200 1200 5600 4000 2700 1000 500
Note: The actual capacity also depends on the possible nominal diameters of the cables tobe installed in the end caps.
Closure Type Length [mm] Diameter [mm] Sheath Openinginside outside inside outside [mm]
UCN 5-10 350 523 115 150 280UCN 5-20 580 768 115 150 510
UCN 7-9 oval 292 469 144/190 153/222 220UCN 7-10 350 523 168 204 280UCN 7-15 470 665 168 204 400UCN 7-20 580 768 168 204 510UCN 7-30 830 1020 168 204 760
UCN 9-20 580 768 210 250 510UCN 9-20 oval 580 768 230/252 240/292 510UCN 9-24 690 881 210 250 610UCN 9-28 778 952 210 250 710UCN 9-30 830 1020 210 250 760
UCN 11-20 580 768 270 312 510UCN 11-30 830 1020 270 312 760UCN 11-40 1080 1274 270 312 1010
20 Corning Cable Systems
��� ������������������$������
Closure Type Delivery Unit Order Number
UCN 5-10 1 pc. S45754-A2-A1UCN 5-20 1 pc. S45054-A304-A6
UCN 7-9 oval 1 pc. S45054-A303-A33UCN 7-10 1 pc. S45054-A303-A21UCN 7-15 1 pc. S45054-A303-A34UCN 7-20 1 pc. S45054-A303-A22UCN 7-30 1 pc. S45054-A303-A23
UCN 9-20 1 pc. S45054-A302-A19UCN 9-20 oval 1 pc. S45054-A302-A61UCN 9-24 1 pc. S45054-A302-A20UCN 9-28 1 pc. S45754-A2-A2UCN 9-30 1 pc. S45054-A302-A21
UCN 11-20 1 pc. S45054-A301-A19UCN 11-30 1 pc. S45054-A301-A20UCN 11-40 1 pc. S45054-A301-A21
Designation Delivery Unit Order Number
Two-section End Caps with valve, without sealing ring and aluminum collar
UCN 5-... 1 pc. S45056-M134-A30UCN 7-... 1 pc. S45056-M134-A32UCN 7-... oval 1 pc. S45756-M1-A3UCN 9-... 1 pc. S45056-M134-A34UCN 9-... oval 1 pc. S45756-M1-A2UCN 11-... 1 pc. S45056-M134-A36
Two-section End Caps with grounding device,without sealing ring and aluminum collars
UCN 5-... 1 pc. S45056-M134-A31UCN 7-... 1 pc. S45056-M134-A33UCN 7-... oval 1 pc. S45756-M1-A5UCN 9-... 1 pc. S45056-M134-A35UCN 9-... oval 1 pc. S45756-M1-A4UCN 11-... 1 pc. S45056-M134-A37
Spare Parts
Closures
All closures with 1 valve and 1 grounding device
21Corning Cable Systems
��� �������������
�����$������
Designation Delivery Unit Order Number
Three-section End Caps with grounding device,sealing ring and aluminum collar
UCNT 9-... 1 pc. S45056-M134-A39UCNT 11-... 1 pc. S45056-M134-A38
One-section End Cap without cable entries(By using one end cap without cable entries, the closurecan be used as a canister closure)
UCNF 9-... 1 pc. C45197-K18-B13
Aluminum Collars for end caps incl. bolts
UCN 5-... 1 pc. S45056-M134-A60UCN 7-... 1 pc. S45056-M134-A70UCN 7-... for oval end caps 1 pc. S45756-M1-A10UCN 9-... 1 pc. S45056-M134-A80UCN 9-... for oval end caps 1 pc. S45756-M1-A11UCN 11-... 1 pc. S45056-M134-A90
Sealing Rings for end caps (M-Profile with joiner clip)
UCN 5-... 10 pcs. S45756-M1-A90UCN 7-... also for oval end caps 10 pcs. S45756-M1-A91UCN 9-... 10 pcs. S45756-M1-A92UCN 9-... for oval end caps 10 pcs. S45756-M1-A93UCN 11-... 10 pcs. S45756-M1-A94
Longitudinal Sealing for closure tubes
UCN 5-10 5 pcs. S45756-M1-A80UCN 7-9 5 pcs. S45756-M1-A13UCN 7-10 5 pcs. S45056-M135-A80UCN 7-15 5 pcs. S45756-M1-A14UCN 5- / 7- / 9- / 11-20 5 pcs. S45056-M135-A90UCN 9-24 5 pcs. S45056-M135-A100UCN 9-28 5 pcs. S45756-M1-A15UCN 7- / 9- / 11-30 5 pcs. S45056-M135-A110UCN 11-40 5 pcs. S45056-M135-A120
Installation Material
Sealing Paste, 20 g 10 pcs. S45056-M83-A10Sealing Tape, 1 roll 5 pcs. S45056-M135-A132Lubricant, 10 x 20 g, 5 brushes 1 set S45056-M135-A150Desiccant, 50 g 1 pc. S45056-M130-A3Cable Sheath Clip 10 pcs. S45056-M80-A3Cable Sheath Connection Wire, 180 mm 10 pcs. S45056-M135-A140Aerial Hanging Device 1 set S45754-D1-A1
Spare Parts and Accessories
22 Corning Cable Systems
��������������������������������
Application
Universal vault closures UCNV serve to distributeoutdoor trunk cables onto indoor distribution cableswithin exchanges. There, the vault closures can be in-stalled in any position in cable vaults or other spaces.The size of the vault closure to be used depends onthe number of distribution cables to be led out, as wellas on the number of pairs and the conductor cross-section.For special requirements, RXS also offers a flame-retardant closure of the type UCN FR. The materialused complies with UL 94 V0. This version meets therequirements for flame-resistant closures to BellcoreTR-NWT-001058.
Special Features
• Designed as vault closure in non-pressurized cablenetworks
• One end cap suitable for accommodation of max.20 distribution cables
• Strain relief for trunk cable is integrated in the end cap• No corroding external metal parts• No special tool required for opening or closing
Design
Universal vault cable closures are available in twovariants:1. Complete UCNV vault closures (3 different sizes)
with all components necessary for installation inone closure package.
2. Individual distribution end caps (2 different sizes)to be combined with the well-known UCN universalclosures. To produce the desired vault closure, asuitable UCN closure with a corresponding capa-city has to be selected and one of the end capsincluded in the UCN closure package has to bereplaced by the corresponding vault cable end cap.
The UCNV vault closures comprise a two-sectionplastic end cap for the trunk cable, an aluminumdistribution end cap with the appropriate number ofcable entries with rubber sealings for the distributioncables and the longitudinally split closure tube, as wellas the necessary installation accessories. Unusedcable entries are to be closed with dummy plugs.Adapter plugs are available to adapt the cable entriesfor smaller cable diameters.
23Corning Cable Systems
�����������������������
�����������������������
Kit Content
1 Closure tube2 Splice protection3 Longitudinal sealing4 Connecting bars5 End cap for trunk cable6 Grounding wire7 Clamping bars8 Sealing tape9 Sealing paste
10 End cap for distribution cables11 Sealing rings (M-profile with joiner clips)12 Cable sheath clip13 Gauge14 Measuring tape15 Cleaning tissues16 Lubricant17 Brush18 Installation instructions
1314
15
18
1716
1
2
3
4
5
6 7 8
9 1011
12
Installation
Detailed installation instructions are enclosed in eachclosure pack. Installation requires a "Tool Case forInstallation of Universal Closures UCN" which has tobe ordered separately (see page 26).
24 Corning Cable Systems
�����������������������������"�����������������$������
Closure Type Number of Length Diameter SheathDistribution [mm] [mm] Opening
Cables inside outside inside outside [mm]
UCNV 7-15/10 10 470 665 168 204 400
UCNV 9-20/12 12580 768 209 247 510
UCNV 9-20/20 20
Capacity in Pairs Capacity in PairsModular Splice (25 pairs) Single Splice,
Closure Type or AMP-TEL Splice orAMP-Mini PICABOND Splice1 Scotchlok Connecting Splice2
Conductor Diameter [mm] Conductor Diameter [mm]0.4 0.5 0.6 0.9 0.4 0.5 0.6 0.9
UCNV 7-15/10 1.000 700 400 200 1.000 600 400 200
UCNV 9-20/122.400 2.100 1.200 600 2.100 1.900 1.200 500
UCNV 9-20/20
Closure Type Max. Diameter Max. Number of Distribution Cable Diameterof Main Cable Distribution Cables without Adapter Plug with Adapter Plug
UCNV 7-15/10 up to 61 mm 10 25 to 33 mm 16 to 25 mm
UCNV 9-20/12 up to 97 mm 12 25 to 33 mm 16 to 25 mm
UCNV 9-20/20 up to 97 mm 20 16 to 25 mm -
Closure Type Delivery Unit Order Number
UCNV 7-15/10 1 pc. S45054-A303-A35
UCNV 9-20/12 1 pc. S45054-A302-A46
UCNV 9-20/20 1 pc. S45054-A302-A47
Number of Distribution Cables, Dimensions
Capacity in Pairs
Cable Capacity / Diameter
Order Numbers
All closures with external grounding device
Note: The actual capacity also depends on the possible nominal diameters of the cables to be installedin the end caps.
25Corning Cable Systems
Type Max. No. of Distribution For Use with the Following Order NumberDistribution Cables Cable Ø [mm] UCN Types (Order Number)
UCNV 9-/12 12 25 to 33 UCN 9-20 (S45054-A302-A19) S45056-M134-A140UCN 9-24 (S45054-A302-A20)
UCNV 9-/18 18 15 to 27 UCN 9-30 (S45054-A302-A21) S45056-M134-A136
UCN 11-20 (S45054-A301-A19)UCNV 11-/30 30 15 to 27 UCN 11-30 (S45054-A301-A20) S45056-M134-A137
UCN 11-40 (S45054-A301-A21)
�����������������������
��������������������������������!�������
Distribution End Caps
The UCNV aluminum distribution end caps have 12,18 and 30 elastically sealed cable entries, respec-tively. These entries are closed on delivery and canbe opened to accommodate the relevant number ofdistribution cables. The UCNV end caps are suppliedwith a sealing ring and installation instructions, areinstalled instead of standard UCN end caps and are tobe combined with the UCN closures listed in the tablebelow.
Distribution End Caps
Designation Delivery Unit Order Number
Dummy Plugs 5 pcs. S45054-A107-R10
Adapter Plugs 5 pcs. S45054-A174-R10
Installation Material for Complete UCNV Closures
26 Corning Cable Systems
Designation Dimensions [mm] Weight [kg] Order Number
Tool Case for UCN closures 650 x 430 x 130 14 S45055-M119-A13
���������������������� ����������������!%������&���������
Application
The tool case contains all standard tools and specialtools (hand-driven drilling tool) which are neccessaryfor installation of the whole UCN closure family.
27Corning Cable Systems
���������������������� ����������������
&����
Designation Application Order Number
Tool Case, empty For attaching tools C46365-K1-A1Tool Insert C45365-A4-C20Lid Insert C45365-A4-C23Drilling Tool For UCN end caps C45407-A62-A13Spare Blade For drilling tool C45407-A62-C6Installation Block For closing and re-opening UCN C45197-A127-B115Cable Sheath Cutter For splitting plastic cable sheaths S45056-Z472-A3
PunchFor punching holes in plastic
C45407-A62-A4sheaths for attaching sheath clips
Socket WrenchFor mounting sheath clips,
10 x 10 mmconnecting bars and grounding straps, S45056-Z426-A3and for using the drilling tool
Socket WrenchFor grounding of UCN S45056-Z426-A24
11 x 11 mmSocket Wrench
For installation of UCN end caps S45056-Z426-A213 x 13 mmWrench, 10 mm For mounting the sheath clips S45056-Z468-A29Lubricant, 50 g For drilling tool S45057-Z901-H460Scissors For cutting the sealing material S45056-Z405-A6Pliers Removing of sealing band from UCN end caps S45057-Z301-H83Allen Wrench, 4 mm For replacing blade of drilling tool S45056-Z445-A8Holder As a support for drilling tools C45407-A62-C137Test/Adjusting Instructions To test and adjust the drilling tool S45055-M119-P430
28 Corning Cable Systems
��� ������������������������
Application
The MHS P mechanical closure is used on all types ofcommunication cables up to 3000 pairs. It providesprotection for straight or branched cable connections.For both new installation and rehabilitation, it can beused on pressurized and non-pressurized cables.
Features
• Complies to the strong requirements ofspecifications for pressurized closures
• Full closure range for cables up to 3000 pairs• Conforms to all splice configurations• Easy and rapid access to the splice for repair and
service• No use of resin• No use of outside energy, e.g. flame or electricity• Flash test at 750 mbar / 15 minutes
Design
The MHS P comprises:• Two half-shells made of black plastic• One end cap providing the sealing and strain relief
for one or two incoming cables• One end cap providing the sealing and strain relief
for up to four outgoing cables• A set of silicon seals providing sealing of the closure
To insert the cables into the end caps, selected for thetype of connection and cable, simply cut out the cableinlets using the specially designed punching pliers.The cables are sealed by applying sealing tapes to theend caps and around the cables. This sealingcompound withstands pneumatic pressure and envi-ronmental stress.Strain relief is provided by a metal strip held aroundthe cables by a metal collar.Silicon seals, fitted around the end caps and in agroove running along the half-shells, provide perfectsealing for the assembly. The half-shells are closedusing non-corrosive screws. The valve is prefitted inthe upper half-shell and the ground connection can beinstalled, on request, on the lower half-shell.
29Corning Cable Systems
��� ���������������
������������&��������
Kit Content
1 Upper half-shell2 Lower half-shell3 End cap for outgoing cables4 Clamping bands5 End cap closing bands6 Metal strips7 Marker letters8 Grapple9 Circular seal
10 Marker tape 4 x 62 (for MHS P no 6 or no 7)11 Gloves12 Paint brush13 Longitudinal seals14 Closing gauge15 Cap closing screws (5 x 35)16 Roll of sealing tape17 Cleaning tissue18 Tube of sealant19 Marker tape20 Sachet of grease21 Holding band22 End cap closing screw23 Grapple24 Circular seal25 End cap for incoming cables26 Clamping band27 Installation instructions (not shown)
1
12
11
109
78
6
5
4
2
13
3
1415
16
17
18
19
20
21
22
23
24
2526
Tool Case
Tool
30 Corning Cable Systems
Dimensions
Closure Type Length [mm] Diameter [mm]Inside Outside Inside Outside
MHS P 4 466 666 135 x 120 195 x 150
MHS P 5 608 808 135 x 120 195 x 150
MHS P 6 680 880 200 x 160 265 x 200
MHS P 7 1030 1230 200 x 160 265 x 200
��� �������������������������!���������������!�����
A B
End Cap 1/2 End Cap 3/4
Type max. cable Ø Dimensions max. cable Ø Dimensions[mm] [mm] [mm] [mm]
A B A B C D
MHS P 4 46 34 135 x 120 36 26 26 36 135 x 120
MHS P 5 46 34 135 x 120 36 26 26 36 135 x 120
MHS P 6 69 59 200 x 160 62 62 62 62 200 x 160
MHS P 7 69 59 200 x 160 62 62 62 62 200 x 160
End Cap 3/4
End Caps, Cable Entries
A B
A B
C D
End Cap 1/2
31Corning Cable Systems
��� ���������������
�����$������
Designation Order Number
MHS P 4 - 1/2 branched S45254-A21-A3MHS P 4 - 3/4 branched S45254-A21-A4MHS P 5 - 1/2 branched S45254-A22-A3MHS P 5 - 3/4 branched S45254-A22-A4MHS P 6 - 1/2 branched S45254-A23-A3MHS P 6 - 3/4 branched S45254-A23-A4MHS P 7 - 1/2 branched S45254-A24-A3MHS P 7 - 3/4 branched S45254-A24-A4
AccessoriesGrounding Device S45254-M2-R5Re-entry kit MHS P 4 & 5 1/2 S45254-A25-A5Re-entry kit MHS P 4 & 5 3/4 S45254-A25-A6Re-entry kit MHS P 6 & 7 1/2 S45254-A25-A7Re-entry kit MHS P 6 & 7 3/4 S45254-A25-A8Tool Case for MHS P S45254-M4-A2
32 Corning Cable Systems
1
23 4
56 7 8 12
911
Kit Content
Each closure package contains all the parts requiredfor one straight joint.
1 Half shells with clamps2 Cable strain reliefs incl. cable shield connections3 Sealing wedges4 Sealing tape5 Half shell gasket6 Cleaning cloth7 Screws for sealing wedges8 Dummy plugs9 Wrap gauge
10 Grounding screws (not shown)11 Shield connection leads12 Installation instructions
��� ����������������������������������
Application
The UCA closures are designed to protect splices atstraight and branch joints on communication cables inunpressurized secondary networks. The closure canbe assembled on all common copper cable types. It issuitable for cut and uncut cables and can be directlyburied in the ground or installed in manholes and onaerial cable routes between and on poles as well as onwalls.
Special Features
• Very fast access to the splice by use of clamps,without influencing the cable entry areas
• Four pre-fabricated cable entries• Half shell closure with resilient sealing of the half
shells permits unlimited re-entry of the closure• Shells closed with clips that are closed manually
and merely require a screwdriver to re-open• Installation without special tools
Design
The UCA is designed as a half shell closure withresilient silicone gasket.
The half shells, with a hinge molded on one long side,are closed with stainless steel clips. The clips can beclosed by hand and levered open again with ascrewdriver. To impede unauthorized access to thesplice compartment, an anti-access device is availableas an accessory.
The cable entries are sealed with the proven sealingtape which is pressed by wedges against the bottomshell.
Unused cable entries are sealed with dummy plugs.All mechanical stresses from outside on the cables areabsorbed by strain-relief elements which are latchedinto the bottom shell. The electrical interconnections ofthe cable sheaths are also connected on these strain-relief elements.
If required, the closure can be supplied with externalgrounding device.
For tightness testing the closure can be flash-testedwith up to 150 kPa / 15 min. air pressure, using avalve inserted in the top shell. After the test the valveis replaced by a sealing screw.
33Corning Cable Systems
��� �������������
�������������������������$��������#���������
Type Dimensions [mm] Weight Cable Capacities in Pairs forOuter Inner Outer Outer [kg] Diameter Conductor DiametersLength Length Width Height [mm] 0.4 mm 0.6 mm 0.8 mm
each closureUCA 3-6 308 150 124 88 2.0
end 2 x to 1870 30 20
UCA 4-9 378 220 160 118 2.8each closure
200 100 50end 2 x to 28
Dimensions, Capacities
The stated splice capacities are obtained from themean pair counts of the largest cables that can beinserted in each entry.
Designation Delivery Unit Order Number
UCA 3-6 with external grounding device 1 pc. S45754-A3-A13UCA 3-6 1 pc. S45754-A3-A12UCA 4-9 with external grounding device 1 pc. S45754-A3-B14UCA 4-9 1 pc. S45754-A3-B15
Order Numbers
When selecting the size of the closure, one shouldalways take into account the number of splices andthe out-side diameters of the cables to be installed.
Designation Delivery Unit Order Number
Cable Branch-off Set for 10 branch cablesincl. strain relief and shield connection
- for UCA 3-6 1 set S45756-M7-A4- for UCA 4-9 1 set S45756-M7-A1
Anti-Access Device
- for UCA 3-6 1 set S45756-M3-A3- for UCA 4-9 1 set S45756-M3-A2
Wall / Pole Mounting for UCA 3-6 and 4-9 1 set S45756-M5-A2Aerial Hanging Device for UCA 3-6 and 4-9 1 set S45756-M5-A1Desiccant 30 g 1 pc. S45056-M130-A2System for Tightness Testing (valve, sealing plug, sealing paste) 10 sets S45756-M5-A7
Accessories
Designation Delivery Unit Order Number
Drilling Tool 1 pc. S45407-A63-A1Filling Compound (re-enterable) 500 g S45057-Z102-H10Sealing Plug 1 pc. S45407-A62-A6
Accessories for Encapsulating the Splice
34 Corning Cable Systems
��� ������������������������
Application
Straight and branching closure for non-pressurizedcopper cable networks with up to 4 cable entries perclosure side.Application area: in manholes, in the ground, on polesand on aerial cables.
Features
• Reliable sealing of the closure due to age-resistant,plastically sealing tapes
• Strain relief elements in the cable entry areas easilyadapted to the cable diameters (onion ring system)
• External metal parts made of non-corroding material• Quick and easy installation without the need for
special tools or additional power source
Design
The lower half shell of the MHS M accommodates thecable splice. The upper half shell covers the splicearea. At the ends of the shells two closing parts areused for covering the cable entry areas. In case of re-opening only the upper half shell has to be removedwhereas the cable entry areas remain unchanged.
Sealing of incoming and outgoing cables is achievedusing sealing tapes and one or two twists of tapesaround the cable. The seams between the half shellsand the closing parts are made watertight with sealingtapes, too.
Strain-relief elements prevent push in or pull out of thecables. These elements are placed beside the sealingelements and can be cut according to the cablediameters on site.
The two half shells and the two closing parts are verytightly joined by non-corroding screws.
35Corning Cable Systems
��� ���������������
������������#���������������$������
Kit Content
1 Upper half shell2 Lower half shell3 Closing part4 Sealing and strain-relief elements5 Sealing tapes round6 Sealing tapes flat7 Shield connection lead8 Knife9 Cleaning tissues
10 Closing screws11 Branching kit (only for branching closure)12 Measuring tape13 Transparent film14 Installation instructions
Types, Application, Order Numbers
Closure Type Application Cable Entries Cable Outlets Order Number
MHS M 1Straight closure 1 1 S45254-A30-A5Branching closure* 1 2 S45254-A30-A6Straight closure 1 1 S45254-A31-A7
MHS M 2 Branching closure* 1 2 S45254-A31-A8Branching closure* 1 3-4 S45254-A31-A9Straight closure 1 1 S45254-A32-A7
MHS M 3 Branching closure* 1 2 S45254-A32-A8Branching closure* 1 3-4 S45254-A32-A9
* In addition to these standard branching closures it is also possible to configure branching closures with 2 or 3-4cable entries. This requires the use of suitable sealing and strain-relief elements from the range of accessoriesand additional branching kits. The MHS M 1 permits a maximum of 2 cable entries.
Branching Kit
The standard branching closures contain branchingkits for the cables to be branched. Each additionalbranching cable requires a further branching kit thathas to be ordered separately.Contents: 1 bridging clip, 1 shield connection lead
Designation Order Number
Branching Kit S45755-M2-A2
1
10
54
2
3
12 11 9 78
6
13
14
3
36 Corning Cable Systems
��� ���������������������������������
Maximum Capacity / Pairs
Closure Type Conductor Diameter Butt Connector* Inline Connector** Modular Connector 25 Pair [mm] [pairs] [pairs] [pairs]
MHS M 1 0.4 30 50 -0.5 - 0.6 30 50 -0.8 - 0.9 20 - -
MHS M 2 0.4 200 250 3000.5 - 0.6 150 250 2000.8 - 0.9 100 - 150
MHS M 3 0.4 300 400 6000.5 - 0.6 300 300 4000.8 - 0.9 150 - 250
*) e.g. 3M UY2 **) e.g. AMP Picabond
Cable Entries: Number per Closure Side and Dimensions
Closure Type Maximum Cable Diameter [mm] 1 Cable Entry 2 Cable Entries 3-4 Cable Entries
MHS M 1 23 13 -
MHS M 2 29 22 19
MHS M 3 40 31 29
Dimensions of Closure Case, Sheath Opening
Closure Type Length [mm] Diameter [mm] Max. Sheath Opening [mm] Inside Outside Inside Outside
MHS M 1 265 360 39 56 225
MHS M 2 480 630 61 78 400
MHS M 3 480 630 81 105 400
37Corning Cable Systems
��� ���������������#���������
For Type Cable Order Number Entries
MHS M 11 S45254-A1-R12 S45254-A1-R3
1 S45254-A2-R1MHS M 2 2 S45254-A2-R11
3-4 S45254-A2-R16
1 S45254-A3-R1MHS M 3 2 S45254-A3-R11
3-4 S45254-A3-R15
Sealing and Strain-Relief Elements
Tool Case
Tools for installation of MHS M.Contents: 1 opening plate, 1 pliers, 1 ratchet wrench,
1 extension, 3 sockets, 1 crank, 1 scissors,1 white marking pen.
Designation Order Number
Tool Case S45254-M2-A4
38 Corning Cable Systems
Pressure Test Set
Set for short-duration tightness testing.Contents: 1 screwdriver with thread, 4 valves,
4 sealing rings.
��� ���������������#���������
Opening Plate
Tool for re-opening the MHS M.
Reclosure Set
For reclosing opened closures.Contents: 1 set of sealing tapes (10 strips),
1 installation instruction.
Designation Order Number
Opening Plate S45254-A4-R12
Designation Order Number
Reclosure Set S45254-A4-R19
Designation Order Number
Pressure Test Set S45254-A4-R1
39Corning Cable Systems
��� ���������������#���������
Fixing Device
For mounting the MHS M on walls or poles and forsuspending from the messenger wires of aerial cables.
Grounding Device
For external grounding.
Designation Order Number
Fixing Device S45254-A4-R15
Designation Order Number
Grounding Device (pack of 5) S45254-A4-R22
40 Corning Cable Systems
Application
Closure for non-pressurized cable networks, especiallydesigned as a distribution closure for up to 10 sub-scriber cables, but also useable as in-line closures forlow-paired distribution cables with up to 30 pairs.Use: in manholes, in buildings, in the ground, on polesand on aerial cables.
Special Features
• Reliable solution for distribution of subscriber cablesinstead of terminals or boxes
• Insertion and sealing of subscriber cables by usingcable glands
• Later insertion of subscriber cables possible at anytime without influencing the cables already installed
• 8 cable gland versions available for all commonsubscriber cable types
• Sealing of the low-paired distribution cables byage-resistant sealing tapes
• No special tools required• Closing screws made of non-corroding metal
� ��� ��� ������������ ���������
Design
The housing of the BPR consists of 4 parts: lower halfshell, two upper closing parts and one upper half shell.
The lower half shell is equipped with 2 cable glandseach on both sides for insertion of max. 4 subscribercables. Glands not used are closed by means ofdummy plugs which are part of the kit.
Each of the two upper closing parts is designed foraccommodation of 3 cable glands. That means inconnection with the 4 cable glands of the lower halfshell 10 cable glands in total for the distribution ofsubscriber cables. These 10 glands are pre-installedwith gland sealing parts 5.2 mm for cable diameter4-6 mm. Gland sealings for other cable diameters orconfigurations are available.
Sealing of the low-paired distribution cables is achie-ved using sealing parts in combination with sealingtapes placed in the lower half shell and in the twoupper closing parts. In addition one or two twists ofsealing tape around the cables ensure a reliablesealing of the cable entry area.
An upper half shell is used to cover the closure. Incase of re-opening only this half shell has to beremoved. The cable entry areas are not influenced.
The seams between the half shells and the closingparts are sealed with a special sealing element.
All the parts of the BPR housing are tightened withnon-corroding screws.
As accessory a metal tray is available which can beinstalled on the bottom of the lower half shell. This trayis suitable to hold IDC connection strips or otherdevices.
41Corning Cable Systems
� ��� ��� ������������
����������
13 3
13
14
12
11
10
9
7
8
5
6
4
2
15
Kit Content
1 Cover2 Lower half shell with 4 cable glands
(2 on each side)3 Closing parts including 3 cable glands each4 Sealing and strain-relief parts for multi-pair cables5 Strain-relief elements for subscriber cables6 Sealing element7 Sealing tapes
8 Dummy plug9 Knife
10 Cleaning tissues11 Closing screws12 Wrench13 Measuring tapes14 Transparent film15 Installation instructions
42 Corning Cable Systems
� ��� ��� ������������ ����������#���������������$������
Application, Order Numbers
Closure Type Application, Max. Cable Ø Order Number1 Branching cable 10 Subscriber Cables*)
BPR 23 mm 14 mm S45254-A5-A6
Dimensions
Inner Dimensions [mm] Outer Dimensions [mm]
Length Width Height Length Width Height
173 80 63 328 117,5 68
Cable Ø Order Number
4 - 5 mm S45254-A6-R134 - 6 mm S45254-A6-R26 - 8 mm S45254-A6-R38 - 10 mm S45254-A6-R4
10 - 12 mm S45254-A6-R512 - 14 mm S45254-A6-R6
Two-wire cables S45254-A6-R7 Three-wire cables S45254-A6-R9
*)For subscriber cables 8 gland sealings for thefollowing cable diameters are available:
With the standard closure 10 gland sealings for cablediameters of 4 - 5 mm are delivered.
43Corning Cable Systems
� ��� ��� ������������
#���������
Support
Wall Mounting Brackets
For mounting the BPR on walls.
Pressure Test Set
Set for short-duration tightness testing.Contents: 1 screwdriver with thread, 4 valves, 4sealing rings.
Messenger Strand Suspension
For suspending the BPR from the messenger wires ofaerial cables.Contents: Set with 2 mounting sets.
Metal Tray
For fixing IDC connection strip or other devices.
Designation Order Number
Wall Mounting Brackets No. 1 S45254-L20-A1
Support S45254-L20-A9
Designation Order Number
Messenger Strand Suspension S45254-A6-R10
Designation Order Number
Pressure Test Set S45254-A4-R1
Designation Order Number
Metal Tray S45254-A6-R14
MountingBrackets
44 Corning Cable Systems
��� �����������!����������
Application
The free-breathing PEV closure is designed as astraight or branching closure on aerial cables.For use on cut and uncut cables.
Features
The PEV closure guarantees an excellent protectionagainst climatic influences in tropical countries. Theventilation principle prevents humidity concentration,independent of air humidity and temperature changes.
• Cable entries individually adaptable on site• Quick re-opening and re-closing without additional
material• For use on cut and uncut cables
Design
The closure consists of two end caps and a closuretube. The end caps are split in two sections to takeuncut cables. The cable entries are designed as ring-shaped segments, like onion rings. They can easily beremoved with a knife which is part of the kit.
Each end cap has two cable entries. Sealing tapewrapped around the cables prevents ingress of water.
Two plastic connection bars link the two end capstogether.
Mechanical forces from the cables are absorbed byserrated plastic parts which are connected with theend caps. These parts are pressed onto the cablesheaths by non-corroding metal hose clamps.
The free-breathing split closure tube is closed bysimply latching into position. The closure is fastened tothe messenger wire by mounting devices.
45Corning Cable Systems
��� �����������!�
���������������������������$�����
Kit Content
1 Closure tube2 End caps3 Hose clamps4 Sealing tapes5 Measuring tape6 Cleaning tissues7 Knife8 Screws9 Serrated parts for strain relief
10 Connecting bars
Mounting Device
1 Messenger wire clamps2 Screws3 Cable ties
Type Dimensions [mm] Delivery Order NumberLength Max. Ø Unit
PEV 560 155 2 kits S45254-A20-A1
1
2
3
Dimensions, Order Number
1
23 4
5
67 8 9
10
46 Corning Cable Systems
�������"��� ���������� ������������!�
Application
The MEP closure is mainly used for temporaryapplications if cable splices have to be made only for ashort time e.g. on construction sites, fair grounds or forcable repairs. They are also used if splices have to besealed up to the final installation e.g. as overnightclosure or under bad weather or environmentalconditions. The use of MEP should not exceed 2weeks in a manhole liable to flooding.
Design
Two half shells serve as splice housing. At the endsthese half shells are filled with gel which forms awatertight seal around the incoming and outgoingcables. Additionally a gel sealing tape is wrappedaround the cable to improve the sealing effect. Theseams between the closure halves are also sealed bygel which is filled in grooves along the sides of the halfshells.
To close the MEP the half shells are pressed togetheruntil they are latched. The MEP is fixed on the cableswith cable ties.
Kit Content
1 Half shells2 Gel sealing tape (one for MEP 1, two for MEP 2)3 Cable ties
Dimensions
Type Usable Inner Length Total Outer Length Inner Diameter Outer Diameter[mm] [mm] [mm] [mm]
MEP 1 277 368 40 44
MEP 2 490 610 77 83
Cable Diameters, Order Numbers
Typ max. Cable Diameter Capacity Order Number[mm] [pairs]
MEP 1 20 14 S45254-A15-A1
MEP 2 32 112 S45254-A16-A1
1
2
3
47Corning Cable Systems
� �����#�����$�%� ���������������&��'�&����'�&�����
���������
Application
GSCFor non-pressurized cable networks - with flexibleprotective liner.
GSC CFor non-pressurized cable networks - with metal can-ister as protection for increased mechanical strength.
GSC CPFor pressurized cable networks - with metal canisterand test valve.
Special Features
• High split resistance due to integrated PE net• Environmentally friendly sleeve composition out of
PE laminate and PE net• No ingress of water into the homogeneous com-
posite material• Very high mechanical strength of sleeve composite• No cable strangulation due to regulated shrink force
of the sleeve• No overheating of cable conductors due to reduced
heat during the shrinking process• Insensitive to sharp flame settings
Design
The reinforced closures have been developed to meetincreased demands in cable networks. For this pur-pose, a PE net has been integrated in the heat-shrink-able sleeve. This considerably increases the split re-sistance during shrinking and its mechanical strength.The inner side of the sleeve is coated with hot-meltadhesive which guarantees a watertight and securebonding to plastic and metal-sheathed cables.A temperature-sensitive paint on the sleeve indicatesthat sufficient heat has been applied to the sleeve.The closure kit consists of the heat-shrinkable rein-forced sleeve with closing channel, a protective liner ora canister, a shield connection lead and installationaccessories.
Accessories for Branching Closures
Branching kit in three different sizes which is requiredfor each branching cable.
48 Corning Cable Systems
� �����#�����$�%� ���������������&��'�&����'�&����������������
Kit Content GSC CP
1 Reinforced heat-shrinkable sleeve2 Closing channel(s)3 Retention clip4 Metal canister with test valve5 Nut and cover screw for valve6 Aluminum adhesive tape7 Plastic adhesive tape8 Shield connection lead9 Emery strip
10 Flame protection foil11 Cleaning tissue12 Installation instructions
Kit Content GSC C
1 Reinforced heat-shrinkable sleeve2 Closing channel(s)3 Retention clip4 Metal canister5 Emery strip6 Shield connection lead7 Plastic adhesive tape8 Aluminum adhesive tape9 Flame protection foil
10 Cleaning tissue11 Desiccant (silica gel)12 Installation instructions
1
3
4
2
67
2
5
8 9
1011
1
234
8
76
5
9
10
1112
1
2 23
45
678
9
1011
12
12
2
Kit Content GSC
1 Reinforced heat-shrinkable sleeve2 Closing channel(s)3 Retention clip4 Cardboard liner5 Laminated aluminum foil6 Emery strip7 Shield connection lead8 Plastic adhesive tape9 Flame protection foil
10 Cleaning tissue11 Desiccant (silica gel)12 Installation instructions
49Corning Cable Systems
� �����#�����$�%� ���������������&��'�&����'�&�����
'������(��������������������$������
Dimensions and Order Numbers of Closures
Type Diameter over Cable Sheath Branching Order NumberSplice Protection Diameter Opening Kit
max. min. max. Type[mm] [mm] [mm]
GSC
43/8-150 43 8 150 A S46896-A1000-A143/8-300 43 8 300 A S46896-A1000-A3055/12-150 55 12 150 A S46896-A1005-A1455/12-300 55 12 300 A S46896-A1005-A175/15-250 75 15 250 A S46896-A1006-A175/15-300 75 15 300 A S46986-A1006-A275/15-430 75 15 430 A S46896-A1006-A393/25-250 93 25 250 B S46896-A1012-A193/25-430 93 25 430 B S46896-A1012-A293/25-530 93 25 530 B S46896-A1012-A3120/28-250 120 28 250 B S46896-A1016-A1120/28-430 120 28 430 B S46896-A1016-A2120/28-530 120 28 530 B S46896-A1016-A3137/38-430 137 38 430 C S46898-A1018-A1137/38-530 137 38 530 C S46896-A1018-A2
Branching Kit
One branching kit is required per branching cable. Thekits are to be ordered separately.
Content
1 Branching clamp2 Bridging clip3 Shield connection lead
3
2
1
Branching Kit Type For Closure Type Order Number
A (small)GSC, GSC C
S46896-A1-R33B (medium)
(for non-pressurized cables)S46896-A1-R34
C (large) S46896-A1-R35BP (medium) GSC CP S46896-A1-R42CP (large) (for pressurized cables) S46896-A1-R43
For GSC C and GSC CP, see next page
50 Corning Cable Systems
Type Diameter over Cable Sheath Branching Order Number Splice Protection Diameter Opening Kit
max. min. max. Type[mm] [mm] [mm]
GSC C
43/8-200 43 8 200 A S46896-A1000-A343/8-350 43 8 350 A S46896-A1000-A443/8-500 43 8 500 A S46896-A1000-A3175/15-300 75 15 300 A S46896-A1006-A475/15-350 75 15 350 A S46896-A1006-A575/15-500 75 15 500 A S46896-A1006-A675/15-650 75 15 650 A S46896-A1006-A3893/25-300 93 25 300 B S46896-A1012-A493/25-500 93 25 500 B S46896-A1012-A593/25-600 93 25 600 B S46896-A1012-A6120/28-400 120 28 400 B S46896-A1016-A4120/28-500 120 28 500 B S46896-A1016-A5120/28-600 120 28 600 B S46896-A1016-A6160/45-500 160 45 500 C S46896-A1027-A1160/45-700 160 45 700 C S46896-A1027-A2200/55-500 200 55 500 C S46896-A1031-A1200/55-700 200 55 700 C S46896-A1031-A2
GSC CP
62/15-300 62 15 300 BP S46896-A2006-A162/15-350 62 15 350 BP S46896-A2006-A262/15-500 62 15 500 BP S46896-A2006-A362/15-650 62 15 650 BP S46896-A2006-A993/30-300 93 30 300 BP S46896-A2011-A193/30-500 93 30 500 BP S46896-A2011-A293/30-600 93 30 600 BP S46896-A2011-A3120/35-400 120 35 400 BP S46896-A2016-A1120/35-500 120 35 500 BP S46896-A2016-A2120/35-600 120 35 600 BP S46896-A2016-A3120/35-900 120 35 900 BP S46896-A2016-A9160/55-500 160 55 500 CP S46896-A2026-A1160/55-700 160 55 700 CP S46896-A2026-A2160/55-900 160 55 900 CP S46896-A2026-A9200/65-500 200 65 500 CP S46896-A2031-A1200/65-700 200 65 700 CP S46896-A2031-A2200/65-900 200 65 900 CP S46896-A2031-A5
� �����#�����$�%� ���������������&��'�&����'�&��������������������$������
51Corning Cable Systems
Type Conductor 3M UY 2 AMP Picabond AVH AVL/MS2 AVL/MS2 AVL/MS2
Sheath Diameter Butt Inline B-wire 10/20 Pairs 25 Pairs 25 Pairs +Opening Connector Connector Conn. Sealant Box
[mm] [pairs] [pairs] [pairs] [pairs] [pairs] [pairs]
0.4 10-30 10-30 10-30 - - -43/8-150 0.5-0.6 10 10-30 10-30 - - -
0.8-0.9 10 - 10 - - -0.4 - 10-50 10-50 - - -
43/8-300 0.5-0.6 10-30 10-50 10-30 - - -0.8-0.9 10-20 - 10-20 - - -
0.4 30-75 30-100 30-75 30-100 30-100 -55/12-300 0.5-0.6 20-50 20-100 20-50 20-50 - -
0.8-0.9 10-50 - 10-30 - - -0.4 50-100 50-150 50-100 50-200 50-250 50-150
75/15-250 0.5-0.6 50-75 50-150 50-75 50-150 50-150 50-1000.8-0.9 10-50 - 10-50 10-50 10-100 -
0.4 50-200 50-250 50-150 - - -75/15-300 0.5-0.6 50-100 50-250 50-100 - - -
0.8-0.9 10-100 - 10-75 - - -0.4 50-250 50-300 50-200 50-300 50-400 50-250
75/15-430 0.5-0.6 50-150 50-300 50-150 50-200 50-250 50-2000.8-0.9 10-100 - 10-75 10-100 10-150 10-100
0.4 200-250 200-300 200 200-300 200-300 200-25093/25-250 0.5-0.6 150 150-300 150 150-200 150-250 150-200
0.8-0.9 30-150 - 30-100 30-150 30-200 30-1500.4 200-400 200-500 200-400 200-600 200-600 200-500
93/25-430 0.5-0.6 150-300 150-500 150-250 150-400 150-500 150-4000.8-0.9 30-250 - 30-150 30-250 30-300 30-250
0.4 200-400 200-500 200-400 - - -93/25-530 0.5-0.6 150-300 150-500 150-250 - - -
0.8-0.9 30-250 - 30-150 - - -0.4 250-400 250-500 250-300 250-600 250-600 250-500
120/28-250 0.5-0.6 200-250 200-500 200-250 200-300 200-500 200-4000.8-0.9 50-250 - 50-200 50-300 50-300 50-300
0.4 250-600 250-900 250-500 250-500 250-900 250-800120/28-430 0.5-0.6 200-400 200-900 200-400 200-600 200-800 200-600
0.8-0.9 50-300 - 50-300 50-400 50-500 50-4000.4 250-600 250-900 250-600 - - -
120/28-530 0.5-0.6 200-500 200-900 200-500 - - -0.8-0.9 50-300 - 50-300 - - -
0.4 400-800 400-900 400-600 400-1000 400-1000 400-900137/38-430 0.5-0.6 300-600 300-900 300-500 300-600 300-800 300-600
0.8-0.9 100-300 - 100-300 100-400 100-500 100-4000.4 400-800 400-900 400-600 400-1000 400-1000 400-900
137/38-530 0.5-0.6 300-600 300-900 300-500 300-600 300-800 300-6000.8-0.9 100-300 - 100-300 100-400 100-500 100-400
� �����#�����$�%� ��������������&��
�����������)���
Single Connectors Modular Connectors
52 Corning Cable Systems
Single Connectors Modular Connectors
Type Conductor 3M UY 2 AMP Picabond AVH AVL/MS2 AVL/MS2 AVL/MS2
Sheath Diameter Butt Inline B-wire 10/20 Pairs 25 Pairs 25 Pairs +Opening Connector Connector Conn. Sealant Box
[mm] [pairs] [pairs] [pairs] [pairs] [pairs] [pairs]
0.4 10-30 10-50 10-50 - - -43/8-200 0.5-0.6 10-30 10-30 10-30 - - -
0.8-0.9 10-20 - 10-20 - - -0.4 10-50 10-75 10-75 - - -
43/8-350 0.5-0.6 10-30 10-75 10-30 - - -0.8-0.9 10-30 - 10-30 - - -
0.4 100 150 50-100 75-200 75-250 75-15075/15-300 0.5-0.6 75 75-150 50-75 50-100 50-150 50-100
0.8-0.8 10-50 - 10-50 30-100 30-100 -0.4 75-200 75-250 75-150 - - -
75/15-350 0.5-0.6 50-150 50-250 50-100 - - -0.8-0.9 30-100 - 30-75 - - -
0.4 75-250 75-300 75-200 75-300 75-400 75-25075/15-500 0.5-0.6 50-150 50-300 50-150 50-200 50-200 50-200
0.8-0.9 30-100 - 30-100 30-100 30-150 30-1000.4 200-250 200-300 200 200-300 200-300 200-250
93/25-300 0.5-0.6 150-200 150-300 150 150-200 150-250 150-2000.8-0.9 50-150 - 50-100 50-150 50-200 50-150
0.4 200-400 200-500 200-400 200-600 200-600 200-50093/25-500 0.5-0.6 150-300 150-500 150-250 150-400 150-500 150-400
0.8-0.9 50-250 - 50-150 50-250 50-300 50-2500.4 200-400 200-500 200-400 - - -
93/25-600 0.5-0.6 150-300 150-500 150-250 - - -0.8-0.9 50-250 - 50-150 - - -
0.4 300-500 300-600 300-400 300-600 300-600 300-500120/28-400 0.5-0.6 200-400 200-600 200-300 200-300 200-500 200-400
0.8-0.9 50-250 - 50-250 50-300 50-300 50-3000.4 300-600 300-900 300-500 300-900 300-900 300-800
120/28-500 0.5-0.6 200-400 200-900 200-400 200-600 200-800 200-6000.8-0.9 50-300 - 50-300 50-400 50-500 50-400
0.4 300-800 300-900 300-600 - - -120/28-600 0.5-0.6 200-500 200-900 200-600 - - -
0.8-0.9 50-300 - 50-300 - - -0.4 800-1000 800-1200 800-900 800-1600 800-1800 800-1200
160/45-500 0.5-0.6 400-900 400-1200 400-800 400-1000 400-1200 400-9000.8-0.9 200-500 - 200-500 200-600 200-800 200-500
0.4 800-1200 800- 800-1000 800-1800 800-2000 800-1800160/45-700 0.5-0.6 400-1000 - 400-900 400-1200 - 400-1200
0.8-0.9 200-600 - 200-600 200-800 - 200-8000.4 1200-1800 1200- 1200-1800 1200-2400 1200-2400 1200-2400
200/55-500 0.5-0.6 1200 - 800-1200 800-1200 - 800-12000.8-0.9 250-800 - 250-800 250-800 - 250-800
0.4 1200-2400 1200- 1200-2400 - - -200/55-700 0.5-0.6 1200 - - - - -
0.8-0.9 250-800 - - - - -
�� �����!�����"�#� �$������������%���������������)���
53Corning Cable Systems
Single Connectors Modular Connectors
Type Conductor 3M UY 2 AMP Picabond AVH AVL/MS2 AVL/MS2 AVL/MS2
Sheath Diameter Butt Inline B-wire 10/20 Pairs 25 Pairs 25 Pairs +Opening Connector Connector Conn. Sealant Box
[mm] [pairs] [pairs] [pairs] [pairs] [pairs] [pairs]
0.4 100 150 50-100 75-200 75-250 75-15062/15-300 0.5-0.6 75 75-150 50-75 50-100 50-150 50-100
0.8-0.9 10-50 - 10-50 30-100 30-100 -0.4 75-200 75-250 75-150 - - -
62/15-350 0.5-0.6 50-150 50-250 50-100 - - -0.8-0.9 30-100 - 30-75 - - -
0.4 75-250 75-300 75-200 75-300 75-400 75-25062/15-500 0.5-0.6 50-150 50-300 50-150 50-200 50-200 50-200
0.8-0.9 30-100 - 30-100 30-100 30-150 30-1000.4 200-250 200-300 200 200-300 200-300 200-250
93/30-300 0.5-0.6 150-200 150-300 150 150-200 150-250 150-2000.8-0.9 50-150 - 50-100 50-150 50-200 50-150
0.4 200-400 200-500 200-400 200-600 200-600 200-50093/30-500 0.5-0.6 150-300 150-500 150-250 150-400 150-500 150-400
0.8-0.9 50-250 - 50-150 50-250 50-300 50-2500.4 200-400 200-500 200-400 - - -
93/30-600 0.5-0.6 150-300 150-500 150-250 - - -0.8-0.9 50-250 - 50-100 - - -
0.4 300-500 300-600 300-400 300-600 300-600 300-500120/35-400 0.5-0.6 200-400 200-600 200-300 200-300 200-500 200-400
0.8-0.9 50-250 - 50-250 50-300 50-300 50-3000.4 300-600 300-900 300-500 300-500 300-900 300-800
120/35-500 0.5-0.6 200-400 200-900 200-400 200-600 200-800 200-6000.8-0.9 50-300 - 50-300 50-400 50-500 50-400
0.4 300-800 300-900 300-600 - - -120/35-600 0.5-0.6 200-500 200-900 200-600 - - -
0.8-0.9 50-300 - 50-300 - - -0.4 800-1000 800-1200 800-900 800-1600 800-1800 800-1200
160/55-500 0.5-0.6 400-900 400-1200 400-800 400-1000 400-1200 400-9000.8-0.9 200-500 - 200-500 200-600 200-800 200-500
0.4 800-1200 800- 800-1000 800-1800 800-2000 800-1800160/55-700 0.5-0.6 400-1000 - 400-900 400-1200 - 400-1200
0.8-0.9 200-600 - 200-600 200-800 - 200-8000.4 1200-1800 1200- 1200-1800 1200-2400 1200-2400 1200-2400
200/65-500 0.5-0.6 1200 - 800-1200 800-1200 - 800-12000.8-0.9 250-800 - 250-800 250-800 - 250-800
0.4 1200-2400 1200- 1200-2400 - - -200/65-700 0.5-0.6 1200 - - - - -
0.8-0.9 250-800 - - - - -
� �����#�����$�%� ��������������&�����
�����������)���
54 Corning Cable Systems
����#��#�����$�%� �����������������('���(�����������
Application
SCXFor non-pressurized cable networks - with flexibleprotection liner.
SCX CFor non-pressurized cable networks - with metalcanister as protection for increased mechanicalstrength.
Design
In contrast to the closure series GSC the sleeves ofthe closures SCX and SCX C are not reinforced.The sleeve of these closures is made of one PE layer.The inner side of the sleeve is coated with hotmeltadhesive which guarantees a watertight and securebonding to plastic and metal-sheathed cables. Atemperature-sensitive paint on the sleeve indicatesthat sufficient heat has been applied to the sleeve. Theclosure kit consists of the heat-shrinkable sleeve withclosing channel, a protective liner or a canister, ashield connection lead and installation accessories.
Accessories for Branching Closures
Branching kit in three different sizes which is requiredwith branching closures for each branching cable.
55Corning Cable Systems
Branching Kit Type Order Number
A (small) S46896-A1-R33B (medium) S46896-A1-R34C (large) S46896-A1-R35
Closure Content SCX C
1 Heat-shrinkable sleeve2 Closing channel(s)3 Retention clip4 Metal canister5 Emery strip6 Shield continuity assembly7 Adhesive tape8 Aluminum adhesive tape9 Flame protection foil
10 Cleaning cloth11 Desiccant12 Installation instructions
����#��#�����$�%� �����������������('���(��
�������������'������(���
Kit Content SCX
1 Heat-shrinkable sleeve2 Closing channel(s)3 Retention clip4 Cardboard liner5 Laminated aluminum foil6 Emery strip7 Shield connection lead8 Plastic adhesive tape9 Flame protection foil
10 Cleaning tissue11 Desiccant (silica gel)12 Installation instructions
1
3
4
2
67
2
5
8 9
1011
1
234
8
76
5
9
10
1112
12
2
Branching Kit
One branching kit is required per branching cable. Thekits are to be ordered separately.
Content
1 Branching clamp2 Bridging clip3 Shield connection lead
3
2
1
56 Corning Cable Systems
����#��#�����$�%� �����������������('���(�����������������$������
Type Diameter over Cable Sheath Branching Order NumberSplice Protection Diameter Opening Kit
max. min. max. Type[mm] [mm] [mm]
SCX
43/ 8-130 43 8 130 A S46896-A67-A10043/ 8-210 43 8 210 A S46896-A67-A10143/ 8-300 43 8 300 A S46896-A67-A10243/ 8-430 43 8 430 A S46896-A67-A103
75/15-160 75 15 160 A S46896-A68-A18475/15-250 75 15 250 A S46896-A68-A18675/15-300 75 15 300 A S46896-A68-A18775/15-430 75 15 430 A S46896-A68-A188
93/25-190 93 25 190 B S46896-A69-A10093/25-250 93 25 250 B S46896-A69-A15993/25-430 93 25 430 B S46896-A69-A102
122/28-190 122 28 190 B S46896-A70-A100122/28-280 122 28 280 B S46896-A70-A101122/28-430 122 28 430 B S46896-A70-A102
137/34-330 137 34 330 C S46896-A71-A104137/34-430 137 34 430 C S46896-A71-A101
SCX C
43/8-200 43 8 200 A S46896-A67-A17143/8-350 43 8 350 A S46896-A67-A9243/8-500 43 8 500 A S46896-A67-A93
75/15-300 75 15 300 A S46896-A68-A18975/15-500 75 15 500 A S46896-A68-A190
93/25-300 93 25 300 B S46896-A69-A15893/25-500 93 25 500 B S46896-A69-A9393/25-700 93 25 700 B S46896-A69-A95
122/28-400 122 28 400 B S46896-A70-A150122/28-500 122 28 500 B S46896-A70-A93122/28-700 122 28 700 B S46896-A70-A95
160/48-500 160 48 500 C S46896-A72-A190160/48-700 160 48 700 C S46896-A72-A94
200/48-500 200 48 500 C S46896-A72-A191200/48-700 200 48 700 C S46896-A72-A158
57Corning Cable Systems
Single Connectors Modular Connectors
����#��#�����$�%� ����������������(
�����������)���
Type Conductor 3M UY 2 AMP Picabond AVH AVL/MS2 AVL/MS2 AVL/MS2Sheath Diameter Butt Inline B-wire 10/20 Pairs 25 Pairs 25 Pairs +Opening Connector Connector Conn. Sealant Box
[mm] [pairs] [pairs] [pairs] [pairs] [pairs] [pairs]
0.4 10-30 10-30 10-30 - - -43/8-130 0.5-0.6 10 10-30 10-30 - - -
0.8-0.9 10 - 10 - - -0.4 10-30 10-50 10-50 - - -
43/8-210 0.5-0.6 10-30 10-50 10-30 - - -0.8-0.9 10-20 - 10-20 - - -
0.4 10-50 10-50 10-75 - - -43/8-300 0.5-0.6 10-30 10-50 10-50 - - -
0.8-0.8 10-30 - 10-30 - - -0.4 10-100 10-150 10-100 - - -
43/8-430 0.5-0.6 10-75 10-150 10-75 - - -0.8-0.9 10-50 - 10-50 - - -
0.4 50-100 50-150 50-100 - - -75/15-160 0.5-0.6 50-75 50-150 50-75 - - -
0.8-0.9 10-50 - 10-50 - - -0.4 50-100 50-150 50-100 50-150 50-200 50-150
75/15-250 0.5-0.6 50-75 50-150 50-75 50-100 50-150 50-1000.8-0.9 10-50 - 10-50 10-100 10-100 -
0.4 50-200 50-250 50-150 - - -75/15-300 0.5-0.6 50-100 50-250 50-100 - - -
0.8-0.9 10-100 - 10-75 - - -0.4 50-250 50-300 50-200 50-300 50-400 50-250
75/15-430 0.5-0.6 50-150 50-300 50-150 50-200 50-200 50-2000.8-0.9 10-100 - 10-75 10-100 10-150 10-100
0.4 150 200 150 400 400 20093/25-190 0.5-0.6 100 150-200 100 250 250 150
0.8-0.9 50 - 50 150 150 1000.4 200-250 200-300 200 200-400 200-400 200-250
93/25-250 0.5-0.6 150 150-300 150 150-250 150-250 150-2000.8-0.9 30-150 - 30-100 30-150 30-200 30-150
0.4 200-400 200-500 200-400 200-600 200-600 200-50093/25-430 0.5-0.6 150-300 150-500 150-250 150-400 150-500 150-400
0.8-0.9 30-250 - 30-150 30-250 30-300 30-2500.4 200-400 250-300 200-400 250-500 250-500 250-400
122/28-190 0.5-0.6 200-250 200-300 200 200-300 200-400 200-3000.8-0.9 50-200 - 50-150 50-250 50-250 50-200
0.4 250-400 250-500 250-300 250-600 250-600 250-500122/28-280 0.5-0.6 200-250 200-500 200-250 200-300 200-500 200-400
0.8-0.9 50-250 - 500-200 50-300 50-300 50-3000.4 250-600 250-900 250-500 250-900 250-900 250-800
122/28-430 0.5-0.6 200-400 200-900 200-400 200-600 200-800 200-6000.8-0.9 50-300 - 50-300 50-400 50-500 50-400
0.4 400-600 400-800 400-600 400-900 400-900 400-800137/34-330 0.5-0.6 300-500 300-800 300-500 300-500 300-500 300-400
0.8-0.9 100-300 - 100-300 100-300 100-300 100-3000.4 400-800 400-900 400-600 400-1000 400-1000 400-900
137/34-430 0.5-0.6 300-600 300-900 300-500 300-600 300-800 300-6000.8-0.9 100-300 - 100-300 100-400 100-500 100-400
58 Corning Cable Systems
Single Connectors Modular Connectors
Type Conductor 3M UY 2 AMP Picabond AVH AVL/MS2 AVL/MS2 AVL/MS2
Sheath Diameter Butt Inline B-wire 10/20 Pairs 25 Pairs 25 Pairs +Opening Connector Connector Conn. Sealant Box
[mm] [pairs] [pairs] [pairs] [pairs] [pairs] [pairs]
0.4 10-30 10-50 10-50 - - -43/8-200 0.5-0.6 10-30 10-30 10-30 - - -
0.8-0.9 10-20 - 10-20 - - -0.4 10-50 10-75 10-75 - - -
43/8-350 0.5-0.6 10-30 10-75 10-30 - - -0.8-0.9 10-30 - 10-30 - - -
0.4 10-100 10-150 10-100 - - -43/8-500 0.5-0.6 10-75 10-150 10-75 - - -
0.8-0.8 10-50 - 10-50 - - -0.4 100 150 50-100 75-200 75-250 75-150
75/15-300 0.5-0.6 75 75-150 50-75 50-100 50-150 50-1000.8-0.9 10-50 - 10-50 30-100 30-100 -
0.4 75-250 75-300 75-200 75-300 75-400 75-25075/15-500 0.5-0.6 50-150 50-300 50-150 50-200 50-200 50-200
0.8-0.9 30-100 - 30-100 30-100 30-150 30-1000.4 200-250 200-300 200 200-300 200-300 200-250
93/25-300 0.5-0.6 150-200 150-300 150 150-200 150-250 150-2000.8-0.9 50-150 - 50-100 50-150 50-200 50-150
0.4 200-400 200-500 200-400 200-600 200-600 200-50093/25-500 0.5-0.6 150-300 150-500 150-250 150-400 150-500 150-400
0.8-0.9 50-250 - 50-150 50-250 50-300 50-2500.4 200-500 200-600 200-500 200-800 200-800 200-600
93/25-700 0.5-0.6 150-300 150-600 150-250 150-500 150-600 150-5000.8-0.9 50-250 - 50-150 50-300 50-400 50-300
0.4 300-500 300-600 300-400 300-600 300-600 300-500122/28-400 0.5-0.6 200-400 200-600 200-300 200-300 200-500 200-400
0.8-0.9 50-250 - 50-250 50-300 50-300 50-3000.4 300-600 300-900 300-500 300-900 300-900 300-800
122/28-500 0.5-0.6 200-400 200-900 200-400 200-600 200-800 200-6000.8-0.9 50-300 - 50-300 50-400 50-500 50-400
0.4 300-800 300-1000 300-600 300-1000 300-1200 300-900122/28-700 0.5-0.6 200-500 200-1000 200-600 200-800 200-900 200-600
0.8-0.9 50-300 - 50-300 50-400 50-600 50-5000.4 800-1000 800-1200 800-900 800-1600 800-1800 800-1200
160/48-500 0.5-0.6 400-900 400-1200 400-800 400-1000 400-1200 400-9000.8-0.9 200-500 - 200-500 200-600 200-800 200-500
0.4 800-1200 800- 800-1000 800-1800 800-2400 800-1800160/48-700 0.5-0.6 400-1000 - 400-900 400-1200 - 400-1200
0.8-0.9 200-600 - 200-600 200-800 - 200-8000.4 1200-1800 1200- 1200-1800 1200-2400 1200-2400 1200-2400
200/48-500 0.5-0.6 1200 - 800-1200 800-1200 - 800-12000.8-0.9 250-800 - 250-800 250-800 - 250-800
0.4 1200-2400 1200- 1200-2400 - - -200/48-700 0.5-0.6 1200 - - - - -
0.8-0.9 250-800 - - - - -
����#��#�����$�%� ����������������(�������������)���
59Corning Cable Systems
����$�%� �������)��������#� �� ������*����(� �+����#��#,'�&��� �+ � �����#,
��������������������������$������
Application
SCX R / GSC R sleeves are used for repairing damag-ed plastic or metal cable sheaths or for providing cor-rosion protection. The sleeves are suitable for all typesof non-pressurized cables in buried, ducted or aerialapplications. Repair sleeves for pressurized cables onrequest.
Design
The sleeves are made of fully cross-linked polyolefinand on the inner surface coated with hot-melt adhesivewhich ensures a permanent and reliable sealing. In ad-dition, the reinforced GSC R sleeves are equippedwith a PE net embedded between the outer and innersleeve layer. A flexible stainless steel channel is usedto close the sleeve. This channel can be cut off aftercooling down of the sleeve.
Installation
The sleeve is wrapped around the cable area to berepaired or protected. With the flame of a standard gastorch the sleeve is shrinked onto the cable sheath.
Type Length Recommended Inner Diameter Order NumberApplication Range
from to from to [mm] [mm] [mm] [mm] [mm]
Standard-Sleeves SCX R
SCX R 1 - 250 250 35 10 43 8 S46898-A1236-A225SCX R 1 - 500 500 35 10 43 8 S46898-A1236-A226SCX R 1 - 750 750 35 10 43 8 S46898-A1236-A227SCX R 1 - 1000 1000 35 10 43 8 S46898-A1236-A228SCX R 1 - 1500 1500 35 10 43 8 S46898-A1236-A251
SCX R 2 - 250 250 50 20 75 15 S46898-A1241-A225SCX R 2 - 500 500 50 20 75 15 S46898-A1241-A226SCX R 2 - 750 750 50 20 75 15 S46898-A1241-A227SCX R 2 - 1000 1000 50 20 75 15 S46898-A1241-A228SCX R 2 - 1500 1500 50 20 75 15 S46898-A1241-A269
SCX R 3 - 250 250 80 30 93 25 S46898-A1250-A225SCX R 3 - 500 500 80 30 93 25 S46898-A1250-A226SCX R 3 - 750 750 80 30 93 25 S46898-A1250-A227SCX R 3 - 1000 1000 80 30 93 25 S46898-A1250-A228SCX R 3 - 1500 1500 80 30 93 25 S46898-A1250-A265
Dimensions, Order Numbers
60 Corning Cable Systems
����$�%� �������)��������#� �� ������*����(� �+����#��#,'�&��� �+ � �����#,���������������$������
Type Length Recommended Inner Diameter Order NumberApplication Range
from to von bis [mm] [mm] [mm] [mm] [mm]
SCX R 4 - 250 250 105 40 122 28 S46898-A1256-A225SCX R 4 - 500 500 105 40 122 28 S46898-A1256-A226SCX R 4 - 750 750 105 40 122 28 S46898-A1256-A227SCX R 4 -1000 1000 105 40 122 28 S46898-A1256-A228SCX R 4 - 1500 1500 105 40 122 28 S46898-A1256-A252
SCX R 5 - 250 250 125 50 137 34 S46898-A1260-A225SCX R 5 - 500 500 125 50 137 34 S46898-A1260-A226SCX R 5 - 750 750 125 50 137 34 S46898-A1260-A227SCX R 5 - 1000 1000 125 50 137 34 S46898-A1260-A228SCX R 5 - 1500 1500 125 50 137 34 S46898-A1260-A253
Reinforced Sleeves GSC R
GSC R 1 - 250 250 35 10 43 8 S46898-A1236-A252GSC R 1 - 500 500 35 10 43 8 S46898-A1236-A253GSC R 1 - 750 750 35 10 43 8 S46898-A1236-A254GSC R 1 - 1000 1000 35 10 43 8 S46898-A1236-A255GSC R 1 - 1500 1500 35 10 43 8 S46898-A1236-A256
GSC R 2 - 250 250 50 20 75 15 S46898-A1241-A270GSC R 2 - 500 500 50 20 75 15 S46898-A1241-A271GSC R 2 - 750 750 50 20 75 15 S46898-A1241-A272GSC R 2 - 1000 1000 50 20 75 15 S46898-A1241-A273GSC R 2 - 1500 1500 50 20 75 15 S46898-A1241-A274
GSC R 3 - 250 250 80 30 93 25 S46898-A1250-A266GSC R 3 - 500 500 80 30 93 25 S46898-A1250-A267GSC R 3 - 750 750 80 30 93 25 S46898-A1250-A268GSC R 3 - 1000 1000 80 30 93 25 S46898-A1250-A269GSC R 3 - 1500 1500 80 30 93 25 S46898-A1250-A270
GSC R 4 - 250 250 105 40 120 28 S46898-A1256-A253GSC R 4 - 500 500 105 40 120 28 S46898-A1256-A254GSC R 4 - 750 750 105 40 120 28 S46898-A1256-A255GSC R 4 - 1000 1000 105 40 120 28 S46898-A1256-A256GSC R 4 - 1500 1500 105 40 120 28 S46898-A1256-A257
GSC R 5 - 250 250 140 70 160 55 S46898-A1260-A254GSC R 5 - 500 500 140 70 160 55 S46898-A1260-A255GSC R 5 - 750 750 140 70 160 55 S46898-A1260-A256GSC R 5 - 1000 1000 140 70 160 55 S46898-A1260-A257GSC R 5 - 1500 1500 140 70 160 55 S46898-A1260-A258
GSC R 6 - 250 250 170 80 200 65 S46898-A1269-A221GSC R 6 - 500 500 170 80 200 65 S46898-A1269-A222GSC R 6 - 750 750 170 80 200 65 S46898-A1269-A223GSC R 6 - 1000 1000 170 80 200 65 S46898-A1269-A224GSC R 6 - 1500 1500 170 80 200 65 S46898-A1269-A225
61Corning Cable Systems
&�������%����
Gas Torch Set
The soldering and gas torch set is tailored to therequirements of processing heat-shrink components.The set comprises: Transport and storage box,pistol-grip fitting, torch tips LS 9, LS 30, LS 40,6 m hose, wrench, gas lighter, steel cylinder 425 g,valve and refilling adapter.
Spare parts for gas torch set on request.
Designation Order Number
Gas Torch Set 5VW8520
Corning Cable Systems62
63Corning Cable Systems
����������������� �������������������������������
64 Corning Cable Systems
Characteristics
The 10-pair strips in the 1001/2001 Series have thefollowing characteristics:
• 1001 Series: Cables and jumper sides equippedwith basic IDC clamps
• 2001 Series: Jumper side with double IDC clampsand cable side with single IDC clamps:
uninterruptible jumpering
• Jumper side is higher than cable side:
improved access to IDC clamps
• Wire Ø 0.4 - 0.8 mm
• 3/5-point protection, front-pluggable
• Tools are not required for installing / removing strips
Implementation Options
1001/2001 Series strips are normally installed close tothe subscriber, e.g. in
• Cross-connection cabinets• Terminal distribution boxes• Distribution boxes/cabinets
������������������ ����������
�����������
65Corning Cable Systems
1001 Series Disconnection Strip
The IDC contact springs on the cable side alwaystouch the contact springs on the jumper side. They areonly separated when a disconnection plug is inserted.
1001 Series Switching Strip
The contact springs on the cable side do not touch thecontact springs on the jumper side. Contact is onlyestablished when a protection connector is inserted.
Cable side
Jumper side
Jumper side
Cable side
Jumper side
Cable side
1001 Series Connection Strip
The connection strip is equipped with clamps whichextend from the cable side to the jumper side. Contactcannot be interrupted and switching cannot be trig-gered by inserting a protection connector.
Designation, Delivery Unit Order Number
10 Disconn. Strips C39104-A92-A632 Numbering Strips, 10 Color Marking S45755-B2-A1Labels (DTAG* code compliance)
Designation, Delivery Unit Order Number
10 Connection Str. C39104-A92-A642 Numbering Strips, 10 Color Marking S45755-B2-A3Labels (DTAG* code compliance)
Designation, Delivery Unit Order Number
10 Switch. Strips C39104-A92-A652 Numbering Strips, 10 Color Marking S45755-B2-A2Labels (DTAG* code compliance)
* Deutsche Telekom AG
������������������ ����������
��� ����� ����
66 Corning Cable Systems
2001 Series Disconnection Strip
The jumper side on the 2001 Series disconnectionstrip is equipped with double clamps for uninterruptibleswitching. Apart from this, the 2001 Series disconnec-tion strip corresponds to its 1001 Series counterpart.
2001 Series Connection Strip
The jumper side on the 2001 Series connection strip isalso equipped with double clamps for uninterruptibleswitching. Apart from this, the 2001 Series connectionstrip corresponds to its 1001 Series counterpart.
2001 Series Switching Strip
The contact springs on the cable side do not touch thecontact springs on the jumper side. Contact is onlyestablished when a protection connector is inserted.
Jumper side
Cable side
Jumper side
Cable side
Jumper side
Cable side
Designation, Delivery Unit Order Number
10 Disconn. Strips C39104-A92-A552 Numbering Strips, 10 Color Marking S45755-B2-A14Labels (DTAG* code compliance)
Designation, Delivery Unit Order Number
10 Conn. Strips C39104-A92-A512 Numbering Strips, 10 Color Marking S45755-B2-A4Labels (DTAG* code compliance)
Designation, Delivery Unit Order Number
10 Switch. Strips C39104-A92-A662 Numbering Strips, 10 Color Marking S45755-B2-A15Labels (DTAG* code compliance)
������������������ ����������
���� ����� ����
67Corning Cable Systems
Cable side
Jumper side
Dropwire Connection Strip
The dropwire connection strip is equipped with springterminals on the cable side for dropwire subscribercables (wire diameter 0.4 - 2.0 mm). Apart from this,the dropwire connection strip corresponds to the 1001Series connection strip.
Grounding Strip
All IDC clamps on the grounding strip are connectedto the grounded mounting frame via a groundingcomb. This ensures that all IDC contacts are connect-ed to the ground potential.
Designation, Delivery Unit Order Number
1 Grounding Strip C39104-A92-A67 S45755-B2-A16
Designation, Delivery Unit Order Number
1 Dropwire Connection StripC39104-A92-A1, 1 Color Marking S45755-B2-A5Label (DTAG* code compliance)
* Deutsche Telekom AG
������������������ ����������
��������� ����������������������� ���
68 Corning Cable Systems
a
b
a'
b'
a
b
a'
b'
Grounding Bracket for Protection Plugs
* A grounding bracket must be installed to ensure theconnection from the protection plug to the groundpotential. The frame must be correctly grounded.
Overvoltage Protection Plug*(3-point protection)• Equipped with a 3-electrode arrester plus short-
circuit springs• Wire pair protection• Nominal response voltage 230 V
Designation, Delivery Unit Order Number
Overvoltage Protection Plug, 10 pcs. S45755-B2-A6
Designation, Delivery Unit Order Number
Overvoltage/OvercurrentS45755-B2-A7
Protection Plug, 10 pcs.
Designation, Delivery Unit Order Number
Grounding Brackets, 10 pcs. S45755-B2-A8
Overvoltage/Overcurrent Protection Plug*(5-point protection)• Equipped with a 3-electrode arrester plus short-
circuit springs and two PTCs• Wire pair protection• Nominal response voltage 230 V• Nominal response current 145 mA
������������������ ����������
�����������������������������������
69Corning Cable Systems
� � � �
���
����
H = 27 mm or 54 mmH = 27 mm or 54 mm� � � �
���
����
a a'
b'b
Overvoltage Protection Magazine (without arrester)
• To be equipped with twenty 2-electrode arresterswithout a short-circuit spring
• Protection for 10 wire pairs
Overvoltage Arrester
• Nominal response voltage 230 V
Mounting frame with strip and overvoltage orovervoltage/overcurrent plug
Mounting frame with strip and overvoltage protectionmagazine
Dimensions of Strips with Protection, Installed in a Mounting Frame
For detailed information on protection methods incommunications technology, refer to the "Overvoltageand Overcurrent Protection in TelecommunicationNetworks" (Order No. A45050-W3123-D7-X-7600).
Designation, Delivery Unit Order Number
Overvoltage Protection Mag., 10 pcs. S45055-B20-A10
Overvoltage Arrester, 1 pc. Q69-X224
������������������ ����������
�����������������������������������
70 Corning Cable Systems
1 2 3 4
Cords
Test and connecting cords are available forimplementing tests and measurements, and forjumpering at short notice.
The numbering strips 1...91 and 10...100 (item 2) areincluded in the strip scope of delivery.
Plugs and Marking Caps
Disconnection plugs (item 3 in picture) and dummyplugs (item 4) are available.
Disconnection plugs are used to disconnect internaland external lines. Dummy plugs indicateconnections which must be retained.
Marking caps (item 1) are used to indicate speciallines. They must be clamped between the IDCcontacts.
Type Length Order Number
Test Cord, bi-polar, with 2 adapters for multiple-spring wire plugs 0.25 m S45055-A106-A3Test Cord, bi-polar, with 2 adapters for multiple-spring wire plugs 1.50 m S45055-A106-A2Test Cord, 4 poles, with 4 adapters for multiple-spring wire plugs 1.50 m S45755-B2-A11Connecting Cord, bi-polar 1.50 m S45055-A106-A5Connecting Cord, 4 poles 1.50 m S45755-B2-A12
Test cordConnecting cord
Type Description Color Order Number
Disconn. Plug Has 2 tongues for disconnecting internal and external lines brown S45755-B2-A9
Dummy PlugDoes not disconnect. Has 2 reeds for a wire pair,
red S45755-B2-A10prevents inadvertent disconnection
Marking Caps For 1001 Series red, blue S45055-B20-R2Marking Caps For 2001 Series red, blue S45055-B20-R1
Scope of delivery: each 10 pcs.
Scope of delivery: each 1 pc.
������������������ ����������
�������������������������
71Corning Cable Systems
Tools
Only a few simple tools are required for wiring andtechnical service.
Termination Tool
• For connecting wires• Cutting device with lock for cutting back excess wire
length• Extraction hook for removing connected wires
Arrester Extraction Tool
For inserting and removing arresters in theovervoltage protection magazine.
Designation Order Number
Termination Tool C39407-A139-A13
Designation Order Number
Arrester Extraction Tool C39407-A149-A8
������������������ ����������
����
72 Corning Cable Systems
Mounting Frames
Mounting frames are used to secure strips in maindistribution frames, distribution boxes, etc. They canaccommodate up to 30 strips with label frames andcan be adjusted to the required length using a side-cutting pliers. The cables or wires are threadedthrough the holes provided. Wire protecting grommetscan be ordered specially for this purpose.
Cable Terminal Heads
The cable terminal head is used to house up to 10strips in a cross-connection cabinet. The cable termi-nal head is secured quickly and simply in the jumperframe of the cross-connection cabinet using fourspikes with captive screws (included in scope ofdelivery).
Designation Order Number
Mounting Frame, Height 27 mm S45055-B20-R7Mounting Frame, Height 54 mm S45055-B20-R8Wire Protecting Grommet, 10 pcs. S45055-B20-R4
Designation Order Number
Cable Terminal Head S45055-B20-A1
������������������ ����������
��������!��"������#��� ��"����$����
73Corning Cable Systems
� � � � �
� � �
�� �
Dropwire Connection StripDisconnection Strip 1001/2001 SeriesConnection Strip 1001/2001 SeriesSwitching Strip 1001/2001 SeriesGrounding Strip
Dimensions
Designation Order Number
Label Frame with Label Strip S45055-B20-R6Label Strips, 10 pcs. S45055-B20-A4
Label Frame with Label Strip
Used to identify mounting frames and cable terminalheads (see picture page 72).
� � � � �
� � �
���
Length of the strips: 121 mm
������������������ ����������
%�#���!��"���� �����"������
74 Corning Cable Systems
Technical Data
Contact principle observes DIN IEC 352 Insulation displacement connection to accommodateeither 1 or 2 lines per IDC clamp
Spring material Tin bronzeContact surface Ag (4 - 7 µm) Contact surfaceModule material PolycarbonateSuitable for:Cable side:1001/2001 Series strips Solid conductor with a diameter of 0.4 - 0.8 mm
Outside diameter max. 1.4 mm (a solid conductordiameter 0.8 mm)
Grounding strip Solid conductor with a diameter of 0.4 to max. 2.0 mmDropwire connection strip Outside diameter max. 2.6 mm
(with PE or PVC insulation)Jumper side:1001/2001 Series strips and Solid conductor with a diameter of 0.4 - 0.6 mmDropwire connection strip Outside diameter max. 1.1 mm
(with PE or PVC insulation)Service lifewith 0.4 - 0.6 mm Ø 200 clampingswith 0.8 mm Ø 50 clampingswith max. 2.0 mm Ø (dropwire strip) 50 clampingsVolume resistance at clamping point < 2 mOhm (when new)(observes DIN EN 60352-3) < 3 mOhm (in service)Dielectric strength observes
> 2000 Veff(draft) DIN VDE 0845-2
Insulation resistance under lab. conditions> 5 x 1010 Ohm (when new)
observes (draft) DIN VDE 0845-2Surge voltage observes VDE 0433 > 2 kV (surge discharge 10/700 µs)
Ambient conditions25/100/21 Max. cold -25°C
observes DIN EN 6008-1Dry heat +100°CHumidity (constant) 21 days
������������������ ����������
��&���������
75Corning Cable Systems
Application
The weatherproof cross-connection cabinet isdesigned to accommodate cable terminal heads (page72) at switching and distribution points in thecommunications network. As well as terminal heads, arange of other distribution components can beinstalled. If 1001/2001 Series connection anddistribution strips are installed, up to 1200 wire pairscan be connected and distributed in the cross-connection cabinet. Cross-connection cabinets arenormally mounted on a base. Cables are inserted intothe cabinet through the base.
Features of Cross-Connection Cabinet KVz 82
• Plastic housing fiber-glass reinforced• Door/backplane with structured DD enameling• Rupture joints in the side walls so that several
cross-connection cabinets can be connected in arow
• Frame for optical fiber distribution components withzinc coating (electrical conductivity)
• Base plate with rubber grommets• Door stop (left or right, door swing 110º)
Features of Base
• Cable base fiber-glass reinforced• With/without ventilation
Designation Weight Order Number[kg]
Cross-Conn. Cabinet 38 S45052-C1-A1Base without Ventilation 28 S45052-Z31-A21Base with Ventilation 28 S45052-Z31-A25
Cross-Connection Cabinet KVz 82
Base for Cross-Connection Cabinet KVz 82
���������������� ������
76 Corning Cable Systems
Distribution Designation Height Width Depth Weight DistanceEnclosure/ between VerticalBox [mm] [mm] [mm] [kg] Rows
Enclosure FM/K1 500 300 120 5 variableEnclosure FM/K2 500 500 120 7 variableEnclosure FM/K3 700 300 120 9 variableEnclosure FM/K4 700 900 120 12 variable
Box FM/E1 110 180 111 2 variableBox FM/E2 180 180 111 2.5 variableBox FM/E3 180 254 111 3 variableBox FM/E4 254 360 111 3.5 variable
Box FM/B1 210 191 108 0.93 variableBox FM/B2 210 191 108 0.95 variableBox FM/B3 390 223 124 1.5 variable
���������������� ���������������� �!�����������������!��'�(���)������������#�����*���������
Characteristics of FM/K Wall-Mounted DistributionEnclosures
• Compact distribution enclosure (sheet steel)• Steel hood (2 mm sheet steel)• Flanged panel with cable entry at the underside of
the cabinet• Grounding bar and cable support bar installed• Mounting rail for module carriers and cable routing
guides• Painted in RAL 7032• IP 55 protection observes DIN EN 529/10.91
77Corning Cable Systems
Wall-Mounted Distribution Enclosures/Boxesfor 1001/2001 Series
FM/E and FM/B Wall-Mounted Distribution Boxes
Additional equipment variants are possible.
Characteristics of FM/E Wall-Mounted DistributionBoxes
• Compact distribution box, fiber glass-reinforced withpolycarbonate
• Pre-cut with PG for cable entry• Paint RAL 7035• IP 66 protection observes DIN EN 529/10.91• Mounting plate and mounting kit included in scope
of delivery
Number of Max. Capacity Order NumberVertical Per Vertical Row Per Enclosure / BoxRows [10-paired Strips] [pairs]
1 10 100 S45752-Z502-A72 10 200 S45752-Z502-A82 20 400 S45752-Z502-A94 20 800 S45752-Z502-A10
1 3 30 S45752-Z502-A15*1 5 50 S45752-Z502-A161 10 100 S45752-Z502-A172 10 200 S45752-Z502-A18
1 2 20 S45752-Z502-A191 3 30 S45752-Z502-A201 10 100 S45752-Z502-A21
*: Pack of 2
Characteristics of FM/B Wall-Mounted DistributionBoxes
• Compact distribution box, fiber glass-reinforced withpolycarbonate/polyester
• Cable insertion via rubber grommets• Painted in RAL 7032• IP 64 protection observes DIN EN 529/10.91• Mounting frame for 1001/2001 Series strips
included in scope of delivery
78 Corning Cable Systems
"�������!������������������ ������������������ ������������������) &���������#�������������������������'��
Mounting Plate for FM/E
The mounting frames and distribution strips areattached to the mounting plate. The mounting plate isthen installed in the distribution box.
Suitable Delivery Weight Order Numberfor Unit [kg]
FM/E1 10 pcs. 0,5 S45752-Z502-A150FM/E2 10 pcs. 0,6 S45752-Z502-A151FM/E3 8 pcs. 0,6 S45752-Z502-A152FM/E4 4 pcs. 0,6 S45752-Z502-A153
Size Cable Ø Delivery Order Number[mm] Unit
PG 13.5 6-12 10 pcs. S45752-Z502-A161PG 16 10-14 10 pcs. S45752-Z502-A140PG 21 13-18 10 pcs. S45752-Z502-A141PG 29 18-25 10 pcs. S45752-Z502-A142Adapt. Ring f.PG 13.5 10 pcs. S45752-Z502-A146
PG Mounting Kits for FM/E
The cables must be inserted into the box using PGmounting kits so that the FM/E distribution boxesensure IP 54 protection.
PG-Threaded Cable Glands, Adapter Ring for FM/E
The cables must be inserted into the box using PGcable glands so that the FM/E distribution boxesensure IP 66 protection.In the distribution box, the smallest pre-cut hole for thecable gland is size 16. To insert cables with a smallerdiameter (6 - 12 mm) into the distribution box, PG 13.5cable glands must be installed using an adapter ring.
Size Cable Ø Deliv. Order Number[mm] Unit (Kit)
PG 16 10 - 14 1 pc.S45752-Z502-A143
PG 21 13 - 18 1 pc.PG 16 10 - 14 1 pc.PG 21 13 - 18 1 pc.
S45752-Z502-A144PG 29 18 - 25 1 pc.PG 29 quadruple stem 1 pc.
79Corning Cable Systems
"�������!������������������ ������������������ �
$���� ����%���������������'�
15“ Lock for FM/K Distribution Enclosure
Used to retro-fit FM/K distribution enclosures.
Connection Kit for FM/E
Used to connect a row or stack of FM/E distributionboxes.
Size Cable Ø Delivery Order Number[mm] Unit
Pg 16 10-14 20 pcs. S45752-Z502-A155Pg 21 13-18 20 pcs. S45752-Z502-A156Pg 29 18-25 20 pcs. S45752-Z502-A157
Designation Order Number
Hinge Set S45752-Z502-A154
Hinge Set for FM/E
Used to convert the removeable cover into a hingedcover.
Designation Weight Order Number[kg]
Lock 0,1 S46998-Z101-S26Key 0,1 S46998-Z101-S27
80 Corning Cable Systems
81Corning Cable Systems
�������������� �����
82Corning Cable Systems
��������
Training: expertise for your personnel
Total solutions are becoming ever more important forcommunication networks. Of particular importance inthis context are solutions for local networks (LANs) foruse on customer premises, and in the carrier area(e.g. telecommunication, CATV IP net-works) becausethe future lies in the integration of speech, image anddata.
At the same time, as world-spanning informationinfrastructure grows, also the quality requirements tobe met by networked communication solutions aregrowing. This demands knowledge – knowledge thatwe can pass on to you.
No-one can do everything –but everything can be learned
Techniques and products are subject to constantchange. This makes it essential to have staff trained tothe highest levels, who know how to utilize technicalprogress to your advantage. This can only beachieved by continuous training.
Knowledge is precious –which is why we pass it on
As a leading manufacturer of communication cables,cable accessories and networks we are working withour customers to build communication bridges for the21st century.
We realize that the planning, installation andmaintenance of cable systems involvescomprehensive knowledge – something we want toshare with you as part of a genuine partnership.
We do the training – you get the profit
Our worldwide knowledge in cable and networktechnology is channeled into our Training Center. Onthe basis of this knowledge, we develop diverseseminars for your staff.
Our training is aimed at all those who set up or operatecarrier or customer premise cable networks.
By undertaking training before starting on a project youwill avoid costly installation errors, and will put in placea critical prerequisite for the successfulimplementation of your project.
Practical orientation, not theoretical dreams
The balance is critical: theory is necessary, butpracticality dictates what must be done. From theirmany years of practical experience, our trainers knowwhich knowledge and skills are required for each task,and they are in constant contact with development,sales and projects engineering at Corning
We offer many different courses on our products,fiber optic cable splicing and measurement
techniques. For information about current coursesand dates please contact your local sales
representative or visit our website at
http://www.corning.com/cablesystems/europe
83Corning Cable Systems
Headquarters Europe, Asia / Pacific, Africa:
Corning Cable SystemsKistlerhofstraße 17081379 MunichGERMANYTel.: ++ 49 - 89 - 51 11 - 0Fax: ++ 49 - 89 - 51 11 - 34 16
�����
��������������� ��
Germany
Corning Cable SystemsGross-Berliner Damm 82 a12487 BerlinGERMANYTel.: ++ 49 - 30 - 53 03 - 21 41Fax: ++ 49 - 30 - 53 03 - 21 72
France
Corning Cable Systems S.A.28170 FavièresFRANCETel.: ++ 33 - 2 - 37 51 05 58Fax: ++ 33 - 2 - 37 51 81 39
Italy
Corning Cable SystemsVia Cernaia, 210 122 TorinoITALYTel.: ++ 39 - 011 - 5 65 78 11Fax: ++ 39 - 011 - 5 06 95 65
Europe
Spain
Corning Cable SystemsEdificio Bronce, 4th FloorPlaza Manuel Gomez Moreno28020 MadridSPAINTel.: ++ 34 - 91 - 4 56 43 00Fax: ++ 34 - 91 - 4 56 43 20
United Kingdom
Corning Cable SystemsFallows WayWhiston, MerseysideL35 1RZENGLANDTel.: ++ 44 - 151 - 4 43 62 00Fax: ++ 44 - 151 - 4 43 63 98
84Corning Cable Systems
Eastern Europe
Corning Cable SystemsAlexander VolkRegional Sales Director Eastern EuropeKistlerhofstraße 17081379 MunichGERMANYTel.: ++ 49 - 89 - 51 11 31 06Mobile: ++ 49 - 170 - 7 63 21 93Fax: ++ 49 - 89 - 51 11 34 49E-mail: [email protected]
Bosnia-Herzogovina
Corning Cable SystemsMr. Gabriel CorosKistlerhofstraße 17081379 MunichGERMANYTel.: ++ 49 - 89 - 51 11 31 06Mobile: ++ 49 - 172 - 2 86 77 30Fax: ++ 49 - 89 - 51 11 34 49E-mail: [email protected]
Bulgaria
PentacorMr. Radoslav Naidenov1606 Sofia, Iwailo 25-A, App.41113 SofiaTel.: ++ 359 - 2 - 9 71 24 15Mobile: ++ 359 - 88 - 50 60 60Fax: ++ 359 - 2 - 9 71 32 14
Kazakhstan
Siemens KasachstanMr. Oleg LschukZharokov st. 20480008 AlmatyTel.: ++ 7 - 32 72 50 92 69
Latvia
Siemens SIAMr. Ivars AuzaViandes Iela 31010 RigaTel.: ++ 371 - 701 - 55 55 / 55 08Mobile: ++ 371 - 9 21 09 02Fax: ++ 371 - 7 01 55 44E-mail: [email protected]
Poland
ZWUT S.A.Mr. Dariusz KrolUl. Zupnicza 1103-821 WarszawaTel.: ++ 48 - 22 - 6 70 96 84Fax: ++ 48 - 22 - 6 70 94 29E-mail: [email protected]
Romania
EMCOM Ltd.Mr. Ionel Lungu266-268 Calea Rahovei Sector 5BucharestTel.: ++ 40 - 1 - 423 - 41 99Fax: ++ 40 - 1 - 423 - 41 92E-mail: [email protected]
Russia
Siemens OOODr. Evgenij GutsteinUl. Malaya Kaluzhskaya 19117071 MoscowTel.: ++ 7 - 095 - 7 37 19 75Mobile: ++ 7 - 095 - 7 68 89 22Fax: ++ 7 - 095 - 7 37 19 19E-mail: [email protected]
Serbia
Siemens d.o.c.Mr. P. PejicKnez Mihailova 30BeogradTel.: ++ 381 - 11 - 63 04 89Fax: ++ 381 - 11 - 63 00 50
Ukraine
Corning Cable SystemsMr. Alexander VolkKistlerhofstraße 17081379 MunichGERMANYTel.: ++ 49 - 89 - 51 11 31 06Mobile: ++ 49 - 170 - 7 63 21 93Fax: ++ 49 - 89 - 51 11 34 49E-mail: [email protected]
�����
���������� ��
85Corning Cable Systems
Asia, South-East Asia, Australia
Corning Cable SystemsMr. Heinz-Josef PredigerRegional Sales Director Asia / PacificKistlerhofstraße 17081379 MunichGERMANYTel.: ++ 49 - 89- 51 11 - 31 16Mobile: ++ 49 - 171 - 5 66 72 18Fax: ++ 49 - 89 - 51 11 - 34 32E-mail: Heinz-Josef.Prediger@corning .com
Australia
Corning Cables AustraliaMr. Kevin Williams74-84 Main Road, Clayton3168 Melbourne, VictoriaTel.: ++ 61 - 3 - 95 38 23 79Mobile: ++ 61 - 40 - 8 87 89 78Fax: ++ 61 - 3 - 95 38 23 05E-mail: [email protected]
Bangladesh
Siemens Bangladesh Ltd.Mr. Khaled ShamsJiban Bima Tower 12th Fl,10 Dilkusha Commercial Area1000 DhakaTel.: ++ 880 - 2 - 9 56 37 34Mobile: ++ 880 - 2 - 9 55 13 81Fax: ++ 880 - 2 - 9 56 37 40E-mail: [email protected]
India
SPCNLMr. S.N. BhatPlot No. 484-485, Phase III Sector-20, Udyog Vihar122016 Gurgaon/HaryanaTel.: ++ 91 - 124 - 6 34 51 00-09Extn.: 720Fax: ++ 91 - 124 - 6 34 51 11, 6 34 34 85E-mail: [email protected]
Indonesia
P.T. Siemens KOMr. Jujian SudarnoJl. Jend. A., Yani Kav. E 67-68, Pulmos13210 JakartaTel.: ++ 62 - 21 - 4 72 91 00Mobile: ++ 62 - 81 92 93 45Fax: ++ 62 - 21 - 4 72 93 00E-mail: [email protected]
Malaysia
SEEMr. Roger Luckhardt12th Floor,Menara Choy Fook On Jalan Yong Shook Lin46050 Petaling Jaya, SelangorTel.: ++ 603 - 7 51 38 88Mobile: 1 22 02 05 03Fax: ++ 603 - 7 55 73 31E-mail: [email protected]
Philippines
Siemens Inc.Ms. Nenette Eufemio12/F Salcedo Towers169 H.V.Dela Costa Street, Salcedo Village1227 Makati CityTel.: ++ 63 - 2 - 8 14 96 25Mobile: ++ 63 - 917 - 5 31 15 45Fax: ++ 63 - 2 - 8 14 97 05E-mail: [email protected]
Siemens Inc.Mr. Roberto B. Cuevas12/F Salcedo Towers169 H.V.Dela Costa Street, Salcedo Village1227 Makati CityTel.: ++ 63 - 2 - 8 14 96 19Mobile: ++ 63 - 917 - 5 27 96 56Fax: ++ 63 - 2 - 8 14 97 05E-mail: [email protected]
Singapore
SAEMr. Albert Tan164 Kallang Way 05-04, Kolam Ayer Industrial Estate349248 SingaporeTel.: ++ 65 - 8 45 46 51Mobile: ++ 65 - 96 75 47 87Fax: ++ 65 - 8 45 46 53E-mail: [email protected]
Corning Cable SystemsMr. Henning VogtRegional Sales Dir. South-East Asia / AustraliaKistlerhofstraße 17081379 MunichGERMANYTel.: ++ 49 - 89 - 51 11 - 31 15Mobile: ++ 49 - 170 - 9 15 78 40Fax: ++ 49 - 89 - 51 11 - 34 32E-mail: [email protected]
�����
����� ��������������������
86Corning Cable Systems
Thailand
Siemens Ltd.Apirak SantipiromkulCharn Issara Tower II, 25th Floor,2922/283 New Petchburi Rd, Bangkapi, Huaykwan,10320 BangkokTel.: ++ 66 - 2 - 7 15 45 37Mobile: ++ 66 - 18 15 32 98Fax: ++ 66 - 2 - 7 15 49 36E-mail: [email protected]
Vietnam
FocalMr. Le Ngoc ThaoKm 27 from HCMC, Highway 1, Ngai Thang, Binh AnThuan An DistrictBihn Duong ProvinceTel.: ++ 84 - 650 - 74 90 99Mobile: ++ 84 - 90 91 99 89Fax: ++ 84 - 650 - 74 90 98E-mail: [email protected]
Greater China
Corning Cable SystemsMr. Jianguo XuRegional Sales Director Greater ChinaKistlerhofstraße 17081379 MunichGERMANYTel.: ++ 49 - 89 - 51 11 31 12Fax: ++ 49 - 89 - 51 11 34 32E-mail: [email protected]
Hong Kong
Corning Hongkong Ltd.Mr. Jerry Tse34th F, Nanulife Tower, North PointHong KongTel.: ++ 852 - 28 07 - 27 23Fax: ++ 852 - 28 07 - 21 52E-mail: [email protected]
Siemens Ltd.Mr. Hamann Ngai58th F, Central Plaza,18 Harbour RoadWanchaiHong KongTel.: ++ 852 - 25 83 - 33 88Mobile: ++ 852 - 98 37 - 82 13Fax: ++ 852 - 28 02 - 41 27E-mail: [email protected]
China
Corning Shanghai OfficeMr. Tinghong YuanRoom 3101, Lucky Target Square,500 Chengdu Road North200003 ShanghaiTel.: ++ 86 - 21 - 63 61 - 08 26Fax: ++ 86 - 21 - 63 61 - 08 27E-mail: [email protected]
Taiwan
TranswaveMr. Tony Fang12F, No. 257, Sec. 2, Hoping E. RoadTaipeiTel.: ++ 886 - 2 - 27 05 88 28Fax: ++ 886 - 2 - 27 55 64 11E-mail: [email protected]
U-TechMr. C.L. Lu2F, No.3, Alley 6,Lane 235, Paochiao RoadTaipei-HsienTel.: ++ 886 - 2 - 29 17 - 64 76Fax: ++ 886 - 2 - 29 12 - 31 83E-mail: [email protected]
�����
������������������������������
87Corning Cable Systems
Africa & Middle East
Corning Cable SystemsMr. Oben UlucRegional Sales Director Africa & Middle EastKistlerhofstraße 17081379 MunichGERMANYTel.: ++ 49 - 89 - 51 - 11 - 31 - 17Mobile: ++ 49 - 171 - 5 66 93 28Fax: ++ 49 - 89 - 51 11 - 34 44E-mail: [email protected]
Algeria
Siemens Bureau d’AlgerMr. Aassim Berkane5, rue Mohammed Saadi Souag, B.P. 11216035 HydraTel.: ++ 213 - 2 - 60 72 07Fax: ++ 213 - 2 - 59 13 33
Kingdom of Saudi Arabia
Beit Al EtisalatMr. Bernd PannekP.O.Box 9020911613 RiyadhTel.: ++ 966 - 1 - 4 73 13 00 Ext.555Mobile: ++ 966 - 5 - 4 40 66 79Fax: ++ 966 - 1 - 4 76 93 57E-mail: [email protected]
South Africa
Electhem Electrical ServicesMr. Günter HemetsbergerLa Lucia Glades Office Park, 1st Floor, Building 374, Armstrong Avenue4321 La Lucia, KWA-Zulu NatalTel.: ++ 27 - 31 - 5 72 26 66Mobile: ++ 43 - 66 43 20 32 41Fax: ++ 27 - 31 - 5 72 26 60E-mail: [email protected]
Turkey
Siemens Fiber Optik Kablolari Ltd. Sti.Mr. Cemal SadikiIplikdere Mevkii, Güzeltepe Köyü 849, Ada 2-3 ParselGebze / KocaeliTel.: ++ 90 - 262 - 7 42 06 71Mobile: ++ 90 - 53 27 78 38 77Fax: ++ 90 - 262 - 7 43 18 05E-mail: [email protected]
Siemens Fiber Optik Kablolari Ltd. Sti.Ucgen Plaza No. 7, Kat: 4Cayiryolu Sokak81120 Icerenköy-IstanbulTel.: ++ 90 - 216 - 4 63 54 53Fax: ++ 90 - 216 - 4 63 59 84
�����
�������������������
88Corning Cable Systems
� ��������������������������������������
The following catalogs can be ordered at any timeon the internet www.corning.com/cablesystems/europeor from fax number + 49 - 89 - 32 942 288:
FiberWay(Fiber Optic Cables for Duct and Buried Applications inPhotonic Networks)Languages: German / EnglishOrder Numbers:C1-K15-1-7100 (German)C1-K15-1-7600 (English)
MCS Micro Cabling Systems / S.L.I.M.(Economical Fiber Optic Cable Installation withoutExcavation)Available from 01 / 2001Languages: German / EnglishOrder Numbers:C1-B8-1-7100 (German)C1-B8-1-7600 (English)
FutureLink Modular(Fiber Optic Cabling Systems)Language: German / EnglishOrder Numbers:C1-K18-1-7100 (German)C1-K18-1-7600 (English)
Accessories for Fiber Optic NetworksLanguage: German / EnglishOrder Numbers:C1-K22-1-7100 (German)C1-K22-1-7600 (English)
Connection and Distribution SystemsAvailable from 01 / 2001Languages: German / EnglishOrder Numbers:C1-K21-1-7100 (German)C1-K21-1-7600 (English)
This publication is the exclusive propertyof SCC Special Communication CablesGmbH & Co.KG. This publication must notbe reproduced or copied in any way whatsoeverwithout the express consent in writing of SCC.SCC reserves the right to improve, enhance,and modify the features and specificationsof SCCs’ products without prior notification.The information contained within thispublication has been reproduced in goodfaith and is accurate, to the best of SCCs’knowledge, at the time of printing. However,SCC makes no warranty as to, and will notbe liable on any basis for, the informationcontained within this publication.
COPYRIGHT© 2000SCC Special Communication Cables GmbH & Co. KGP. O. Box 700309D-81303 MunichGermany
Order Number: C1-K20-1-7600Printed in the Federal Republic of GermanyCCS 12003
Visit uson theInternet!http://www.corning.com/cablesystems/europe