Upload
nullka
View
216
Download
0
Tags:
Embed Size (px)
DESCRIPTION
CS Report Cluster
Citation preview
GENEX Assistant Custom ReportDate(20151018)
Author(Assistant User)
www.huawei.com
Contents
GENEX Assistant Custom Report....................................................................................................1
1 Logfile Information...................................................................................................................3
1.1 Probe_20150629225857.gen.....................................................................................3
1.2 Probe_20150629230541.gen.....................................................................................3
2 Drive Test Route.......................................................................................................................3
3 GSM CS Report(Auto Analysis Group 3).................................................................................5
3.1 Statistics Information................................................................................................5
3.1.1 CS Event Summary...........................................................................................5
3.1.2 Call Setup Delay Summary...............................................................................6
3.1.2.1 Call Setup Time (GSMCallSetup - GSMCallAttempt).....................6
3.1.3 Frequency Band Summary................................................................................6
3.1.4 Handover Summary..........................................................................................6
3.1.4.1 Handover Event Summary................................................................6
3.1.4.2 Handover Delay Summary................................................................7
3.1.4.3 Handover Band Summary.................................................................7
3.1.5 SMS Summary..................................................................................................7
3.2 IE Statistics...............................................................................................................8
3.2.1 RxLev Sub........................................................................................................8
3.2.2 RxQual Sub.....................................................................................................10
3.2.3 BER Sub..........................................................................................................11
3.2.4 PESQ P862.1...................................................................................................13
3.2.5 FER Sub..........................................................................................................14
3.2.6 C/I Worst.........................................................................................................16
3.2.7 Power Control Level.......................................................................................17
3.2.8 TA...................................................................................................................19
3.3 Event Troubleshooting............................................................................................20
3.3.1 Event Map.......................................................................................................20
3.3.2 Event Summary.........................................................................................21
Figure 2-1 Table:Logfile Information.......................................................................................4
Figure 2-2 Table:Logfile Information.......................................................................................4
Figure 3-1 Map: Drive Test Route............................................................................................5
Figure 4-1 Table:CS Event Summary.......................................................................................7
Figure 4-2 Table:Call Setup Time (GSMCallSetup - GSMCallAttempt)..................................7
Figure 4-3 Table:Frequency Band Summary............................................................................7
Figure 4-4 Table:Handover Event Summary............................................................................8
Figure 4-5 Table:Handover Delay Summary............................................................................8
Figure 4-6 Table:Handover Band Summary.............................................................................8
Figure 4-7 Table:SMS Summary..............................................................................................9
Figure 4-8 Map:RxLev Sub......................................................................................................9
Figure 4-9 Legend:RxLev Sub................................................................................................10
Figure 4-10 Chart:RxLev Sub.................................................................................................10
www.huawei.com
Figure 4-11 Table:RxLev Sub.................................................................................................10
Figure 4-12 Table:RxLev Sub.................................................................................................10
Figure 4-13 Map:RxQual Sub.................................................................................................11
Figure 4-14 Legend:RxQual Sub............................................................................................11
Figure 4-15 Chart:RxQual Sub...............................................................................................11
Figure 4-16 Table:RxQual Sub...............................................................................................12
Figure 4-17 Table:RxQual Sub...............................................................................................12
Figure 4-18 Map:BER Sub.....................................................................................................12
Figure 4-19 Legend:BER Sub.................................................................................................13
Figure 4-20 Chart:BER Sub....................................................................................................13
Figure 4-21 Table:BER Sub....................................................................................................13
Figure 4-22 Table:BER Sub....................................................................................................13
Figure 4-23 Map:PESQ P862.1..............................................................................................14
Figure 4-24 Legend:PESQ P862.1..........................................................................................14
Figure 4-25 Chart:PESQ P862.1.............................................................................................14
Figure 4-26 Table:PESQ P862.1.............................................................................................15
Figure 4-27 Table:PESQ P862.1.............................................................................................15
Figure 4-28 Map:FER Sub......................................................................................................15
Figure 4-29 Legend:FER Sub.................................................................................................16
Figure 4-30 Chart:FER Sub....................................................................................................16
Figure 4-31 Table:FER Sub....................................................................................................16
Figure 4-32 Table:FER Sub....................................................................................................16
Figure 4-33 Map:C/I Worst.....................................................................................................17
Figure 4-34 Legend:C/I Worst................................................................................................17
Figure 4-35 Chart:C/I Worst...................................................................................................17
Figure 4-36 Table:C/I Worst...................................................................................................18
Figure 4-37 Table:C/I Worst...................................................................................................18
Figure 4-38 Map:Power Control Level...................................................................................18
Figure 4-39 Legend:Power Control Level..............................................................................19
Figure 4-40 Chart:Power Control Level.................................................................................19
Figure 4-41 Table:Power Control Level..................................................................................19
Figure 4-42 Table:Power Control Level..................................................................................19
Figure 4-43 Map:TA...............................................................................................................20
Figure 4-44 Legend:TA...........................................................................................................20
Figure 4-45 Chart:TA..............................................................................................................21
Figure 4-46 Table:TA..............................................................................................................21
Figure 4-47 Table:TA..............................................................................................................21
Figure 4-48 Map:Event Map...................................................................................................22
Figure 4-49 Legend:Event Map..............................................................................................22
Figure 4-50 Table:Event Summary.........................................................................................22
www.huawei.com
Basic Information
1 Logfile Information
1.1 Probe_20150629225857.gen
Log Size(M) MS Name Start Time End Time
2.31387
MS3:HUAWEI
D51(42402161141
7909)
GPS
2015-06-29
23:00:00.576
2015-06-29
23:03:07.775
Figure 2-1 Table:Logfile Information
1.2 Probe_20150629230541.gen
Log Size(M) MS Name Start Time End Time
4.12448
MS3:HUAWEI
D51(42402161141
7909)
GPS
2015-06-29
23:05:43.978
2015-06-29
23:11:41.388
www.huawei.com
Figure 2-2 Table:Logfile Information
2 Drive Test Route
Figure 3-3 Map: Drive Test Route
www.huawei.com
3 GSM CS Report(Auto Analysis Group 3)
3.1 Statistics Information
3.1.1 CS Event Summary
Name Value Target Value
GSMCallSetupFailRF
Counter(MOC)0.00
Call Setup Counter 4.00
Call Drop Counter 0.00
GSMCallSetupFailNotRF
Counter0.00
GSMCallSetupFailNotRF
Counter(MOC)0.00
GSMCallSetupFailNotRF
Counter(MTC)0.00
HO Request Counter 8.00
HO Success Counter 8.00
SDCCH Call Setup
Assigned Counter4.00
SDCCH Call Drop
Counter0.00
Call Setup Success
Rate(Total)(%)100.00%( 4/(0+0 + 4))
Call Drop Rate(Total)(%) 0.00%( 0 / 4)
InterCell HO Success
Rate(%)100.00%( 8 / (8 + 0))
SDCCH Call Drop
Rate(%)0.00%( 0 / 4)
Location Update Counter 1.00
Location Update Failure
Counter0.00
Location Update Failure
Rate(%)0.00%( 0 / 1)
RAU Attempt Counter 1.00
Distance Sum For
All(RxLev >=-90 dBm)5911.69
Kilometer Per Drop
Call(km)--
Cell Reselection Average 180.30s( 540.90 / 3)
www.huawei.com
Interval(s)
Call Setup Delay
Average(s)4.13s( 16.53 / 4)
Figure 4-4 Table:CS Event Summary
3.1.2 Call Setup Delay Summary
3.1.2.1 Call Setup Time (GSMCallSetup - GSMCallAttempt)
Time(s) Count %
[0,2) 0.00 0.00%( 0 / 4)
[2,4) 2.00 50.00%( 2 / 4)
[4,6) 2.00 50.00%( 2 / 4)
[6,8) 0.00 0.00%( 0 / 4)
[8,10) 0.00 0.00%( 0 / 4)
[10,12) 0.00 0.00%( 0 / 4)
[12,15) 0.00 0.00%( 0 / 4)
[15,20) 0.00 0.00%( 0 / 4)
[20,+∞) 0.00 0.00%( 0 / 4)
Total 4.00 100.00%( 4 / 4)Figure 4-5 Table:Call Setup Time (GSMCallSetup - GSMCallAttempt)
3.1.3 Frequency Band Summary
Band Count %
850M 0.00 0.00%( 0 / 1009)
900M 950.00 94.15%( 950 / 1009)
1800M 59.00 5.85%( 59 / 1009)
1900M 0.00 0.00%( 0 / 1009)Figure 4-6 Table:Frequency Band Summary
3.1.4 Handover Summary
3.1.4.1 Handover Event Summary
Name Value Target Value
HO Request Counter 8.00
HO Success Counter 8.00
HO Failure Counter 0.00
InterCell HO Success
Rate(%)100.00%( 8 / (8 + 0))
www.huawei.com
HO Failure Rate(%) 0.00%( 0 / (0 + 8))
IntraCell HO Failure
Counter0.00
IntraCell HO Success
Counter2.00
Figure 4-7 Table:Handover Event Summary
3.1.4.2 Handover Delay Summary
Name Value Target Value
InterCell HO Time Delay
Avg(ms)192.13ms( 1537 / 8)
HO Delay Max 0.24
HO Delay Min 0.17
HO Success Counter 8.00Figure 4-8 Table:Handover Delay Summary
3.1.4.3 Handover Band Summary
Band Count %
IntraBand HO 850->850 0.00 0.00%( 0 / 8)
InterBand HO 850-
>19000.00 0.00%( 0 / 8)
IntraBand HO 900->900 7.00 87.50%( 7 / 8)
InterBand HO 900-
>18001.00 12.50%( 1 / 8)
InterBand HO 1800-
>9000.00 0.00%( 0 / 8)
IntraBand HO 1800-
>18000.00 0.00%( 0 / 8)
InterBand HO 1900-
>8500.00 0.00%( 0 / 8)
IntraBand HO 1900-
>19000.00 0.00%( 0 / 8)
Total 8.00 100.00%( 8 / 8)Figure 4-9 Table:Handover Band Summary
3.1.5 SMS Summary
Name Value Target Value
SMS Sent Counter 0.00
SMS Received Counter 0.00
www.huawei.com
Figure 4-10 Table:SMS Summary
3.2 IE Statistics
3.2.1 RxLev Sub
Figure 4-11 Map:RxLev Sub
www.huawei.com
Figure 4-12 Legend:RxLev Sub
Figure 4-13 Chart:RxLev Sub
Average Maximum MinimumStandard
Deviation
-71.74dBm -47.00dBm -93.00dBm 9.07Figure 4-14 Table:RxLev Sub
Range Count Cumulation(%) Density(%)
[-110,-105) 0 0.00 0.00
(-105,-95] 0 0.00 0.00
(-95,-85] 63 7.10 7.10
(-85,-75] 306 41.60 34.50
(-75,-65] 317 77.34 35.74
(-65,-55] 174 96.96 19.62
(-55,0] 27 100.00 3.04Figure 4-15 Table:RxLev Sub
www.huawei.com
3.2.2 RxQual Sub
Figure 4-16 Map:RxQual Sub
Figure 4-17 Legend:RxQual Sub
Figure 4-18 Chart:RxQual Sub
Average Maximum MinimumStandard
Deviation
www.huawei.com
0.14 7.00 0.00 0.74Figure 4-19 Table:RxQual Sub
Range Count Cumulation(%) Density(%)
[0,1) 849 95.72 95.72
[1,2) 7 96.51 0.79
[2,3) 8 97.41 0.90
[3,4) 8 98.31 0.90
[4,5) 8 99.21 0.90
[5,6) 1 99.32 0.11
[6,7] 6 100.00 0.68Figure 4-20 Table:RxQual Sub
3.2.3 BER Sub
Figure 4-21 Map:BER Sub
www.huawei.com
Figure 4-22 Legend:BER Sub
Figure 4-23 Chart:BER Sub
Average Maximum MinimumStandard
Deviation
0.13% 12.60% 0.00% 0.94Figure 4-24 Table:BER Sub
Range Count Cumulation(%) Density(%)
[0,2) 885 98.12 98.12
[2,4) 8 99.00 0.89
[4,8) 4 99.45 0.44
[8,100] 5 100.00 0.55Figure 4-25 Table:BER Sub
www.huawei.com
3.2.4 PESQ P862.1
Figure 4-26 Map:PESQ P862.1
Figure 4-27 Legend:PESQ P862.1
Figure 4-28 Chart:PESQ P862.1
Average Maximum MinimumStandard
Deviation
0.00 0 0 0.00
www.huawei.com
Figure 4-29 Table:PESQ P862.1
Range Count Cumulation(%) Density(%)
[0,1) 0 0 0
[1,2) 0 0 0
[2,3) 0 0 0
[3,4) 0 0 0
[4,5] 0 0 0Figure 4-30 Table:PESQ P862.1
3.2.5 FER Sub
Figure 4-31 Map:FER Sub
www.huawei.com
Figure 4-32 Legend:FER Sub
Figure 4-33 Chart:FER Sub
Average Maximum MinimumStandard
Deviation
0.00% 0.00% 0.00% 0.00Figure 4-34 Table:FER Sub
Range Count Cumulation(%) Density(%)
[0,2) 888 100.00 100.00
[2,4) 0 100.00 0
[4,8) 0 100.00 0
[8,100] 0 100.00 0Figure 4-35 Table:FER Sub
www.huawei.com
3.2.6 C/I Worst
Figure 4-36 Map:C/I Worst
Figure 4-37 Legend:C/I Worst
Figure 4-38 Chart:C/I Worst
Average Maximum MinimumStandard
Deviation
www.huawei.com
19.27dB 23.60dB 10.45dB 2.71Figure 4-39 Table:C/I Worst
Range Count Cumulation(%) Density(%)
[-30,0) 0 0.00 0.00
[0,5) 0 0.00 0.00
[5,9) 0 0.00 0.00
[9,12) 4 0.40 0.40
[12,20) 429 43.78 43.38
[20,35] 556 100.00 56.22Figure 4-40 Table:C/I Worst
3.2.7 Power Control Level
Figure 4-41 Map:Power Control Level
www.huawei.com
Figure 4-42 Legend:Power Control Level
Figure 4-43 Chart:Power Control Level
Average Maximum MinimumStandard
Deviation
8.38 16 0 4.33Figure 4-44 Table:Power Control Level
Range Count Cumulation(%) Density(%)
[0,5) 198 21.85 21.85
[5,10) 353 60.82 38.96
[10,15) 235 86.75 25.94
[15,20) 120 100.00 13.25
[20,25) 0 100.00 0
[25,31] 0 100.00 0Figure 4-45 Table:Power Control Level
www.huawei.com
3.2.8 TA
Figure 4-46 Map:TA
Figure 4-47 Legend:TA
Figure 4-48 Chart:TA
Average Maximum MinimumStandard
Deviation
www.huawei.com
1.48 4 0 0.84Figure 4-49 Table:TA
Range Count Cumulation(%) Density(%)
[0,1) 83 9.26 9.26
[1,2) 405 54.46 45.20
[2,3) 320 90.18 35.71
[3,4) 73 98.33 8.15
[4,5) 15 100.00 1.68
[5,10) 0 100.00 0
[10,32) 0 100.00 0
[32,63] 0 100.00 0Figure 4-50 Table:TA
3.3 Event Troubleshooting
3.3.1 Event Map
www.huawei.com
Figure 4-51 Map:Event Map
Figure 4-52 Legend:Event Map
3.3.2 Event Summary
Name Value Target Value
SDCCH Call Drop
Counter0.00
Call Drop Counter 0.00
Location Update Failure
Counter0.00
HO Failure Counter 0.00Figure 4-53 Table:Event Summary