2
Vibration Robustness of Electrodes
Maxwell has invested great effort in extending the working envelop of UCAP cells. During this investigation we have found some inherent ways that our dry process electrode preforms better then wet coated electrode under vibration testing. We believe that these results would hold true not only for UCAPS but also batteries made with the dry process.
R. Shaw Lynds, NATTBatt, 2015
Vibration testing of cells ISO 16750 Table 12 for truck chassis mounted electronics
3
Vibration Robustness of Electrodes
Dry Process Wet Coated #1 Wet Coated #2 Wet Coated #3
15 day soak
10 min shake
Post-vibration
Maxwell has observed high ESR increases in UCAPS with wet coated electrodes after vibration testing• Process: binder breakdown => loose carbon,
higher ESR• Electrode level tests: 15 day soak in ACN or 10 min
shake on mixer while folded and soaked in ACN Pre-vibration
R. Shaw Lynds, NATTBatt, 2015
Wet coated cells