23/4/19 1
Innovation Value Teamwork
SHENZHEN INVT ELECTRIC CO., LTD. www.invt.com
Technical features of INVT MVD
outstanding energy
saving effect
outstanding energy
saving effect
High reliabilityHigh reliability
Prefect protection
function
Prefect protection
function
◆ Double power supply redundant design for control system;◆ Abundant power unit monitor function, detect the power unit temperature, DC bus voltage, adjust system in advance to prevent failure.
◆ 11 kinds power cell fault protection function;
◆ More than 20 kinds protection for inverter and motor; ◆ Protection threshold can be adjusted according to working
conditions.
◆ Automatically adjust the output voltage according to the load, save more energy for customers.
Bypass for system
and power cell
Bypass for system
and power cell
◆ Auto-switching between power frequency and variable
frequency technology;
◆ bypass the fault power cell in 200ms, will not cause MVD stop;
◆ synchronous switchover technology, switching the system
between power frequency and variable frequency smoothly
Speed tracing
and start function
Speed tracing
and start function
Good adaptability
for voltage fluctuation
Good adaptability
for voltage fluctuation
complete parameters
record
complete parameters
record
◆ The MVD can output 100% torque while the voltage
fluctuation range is ±10%;
◆ MVD run derating without protection when input voltage
dropping to 65% rated voltage at short time (30s);
◆ Indicate multi-parameters in running status,
temperature of each module, DC bus detection and
indication, provide with fault indication, record and
self-diagnostic function.
◆ When the instantaneous power off, the MVD can be
started smoothly by speed tracing function;
◆ the system can be switched from power frequency to
variable frequency smoothly.
high efficiencyhigh power factor
low harmonics
high efficiencyhigh power factor
low harmonics
◆ Efficiency ≥98 % at rating load
◆ Input power factor ≥0.96;
◆ Input & output harmonic < 2 %
11KV POWER SUPPLY
MVD111KV, 850KW
MVD211KV, 850KW
MVD311KV, 850KW
MVD411KV, 850KW
KM1 KM2 KM3 KM4 KM5 KM6 KM7 KM8
M111KV, 850KW
M211KV, 850KW
M311KV, 850KW
M411KV, 850KW
STANDBY11KV, 850KW
Typical diagram of 11KV MVD connectionsTypical diagram of 11KV MVD connections
690V, VFD
It needs additional step-down transformer, the cable length will be longer, and the transformer cause energy lose, which adds cost.
The harmonic distortion is very high, which calls for additional electric devices like EMC filters and harmonic filters
11KV, MVD
VFD comparisonVFD comparison
Adopt multi-power cell parallel connection technology, Input & Output harmonic less than 2%
Adopt multi-power cell parallel connection technology, Input & Output harmonic less than 2%
The starting current is very high, which may cause current shock for grid
The starting current is very high, which may cause current shock for grid
The starting current is low, reduce the current shock for the grid
The starting current is low, reduce the current shock for the grid
Additional transformer is unnecessaryAdditional transformer is unnecessary
The system can be bypassedThe system can be bypassedThe system can not be bypassedThe system can not be bypassed
690V, VFD
For output side, consider the dv/dt problem, output reactor or filter is recommended
The output cable length is limited
11KV, MVD
VFD comparisonVFD comparison
The output cable length without any limitation. Beneficial to system expansion
The output cable length without any limitation. Beneficial to system expansion
The system is difficult for maintenance The system is difficult for maintenance
The system is modularized structure, it easy for maintenance The system is modularized structure, it easy for maintenance
The output reactor and filter is unnecessaryThe output reactor and filter is unnecessary
The operation interface is not friendly for customer. The operation interface is not friendly for customer.
HMI is used, the system is easy to be operated and monitored,
the interface is more friendly.
HMI is used, the system is easy to be operated and monitored,
the interface is more friendly.
690V, motor
Volume of the motor is big
The output current is big, the cross section of cable should be big, wiring connection is difficult.
11KV, motor
Motor comparisonMotor comparison
The output current is small, big cross section of cable is unnecessary, wiring connection is easy.
The output current is small, big cross section of cable is unnecessary, wiring connection is easy.
Copper loss of motor is bigCopper loss of motor is big Copper loss of motor is small Copper loss of motor is small
Volume of the motor is smallVolume of the motor is small