12
____________________________________________________________________________________ Building Codes Division Department of Consumer and Business Services State of Oregon 1535 Edgewater St. NW, Salem, OR 97304 P.O. Box 14470, Salem, OR 97309-0404 503-378-4133 Fax: 503-378-2322 oregon.gov/bcd Strikethrough text represents deleted language. Underlined text represents added language. Errata Summary: Section 310.5.1 Section 1103.2.16 Section 3411.7, Exception 1 Chapter 11 Figures – Prepared in insert page format (Pages 308 a-j) 310.5.1 Care facilities within a dwelling. Care facilities for five or fewer persons receiving care that are within a single-family dwelling are permitted to comply with the Residential Code. provided an automatic sprinkler system is installed in accordance with Section 903.3.1.3 or with Appendix T of the Residential Code. 1103.2.16 Private membership clubs and churches. In accordance with ORS 447.210(1), private membership clubs and churches that have more than one floor level and more than 4,000 square feet (372 m2) in ground area or more than one floor level and more than 20 feet (9096 mm) in height, measured from the top surface of the lowest flooring to the highest interior overhead finish of the building, are not required to be accessible. 3411.7 Alterations affecting an area containing a primary function. Where an alteration affects the accessibility to, or contains an area of primary function, the route to the primary function area shall be accessible. The accessible route to the primary function area shall include toilet facilities or drinking fountains serving the area of primary function. Exceptions: 1. The costs of providing the accessible route are not required to exceed 20 25 percent of the costs of the alterations affecting the area of primary function. (See ORS 447.241). (2 through 5 unchanged) 2014 OSSC Errata October 16, 2014 Errata for the 2014 Oregon Structural Specialty Code First Printing

2014 OSSC Errata October 16, 2014 Errata for the 2014 ...aisle 9’ min. 8’ min. 9’ min. 17’ min. 36° typ. page 308d 2014 oregon structural specialty code accessibility for

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 2014 OSSC Errata October 16, 2014 Errata for the 2014 ...aisle 9’ min. 8’ min. 9’ min. 17’ min. 36° typ. page 308d 2014 oregon structural specialty code accessibility for

____________________________________________________________________________________

Building Codes Division Department of Consumer and Business Services State of Oregon 1535 Edgewater St. NW, Salem, OR 97304 P.O. Box 14470, Salem, OR 97309-0404

503-378-4133 Fax: 503-378-2322 oregon.gov/bcd

Strikethrough text represents deleted language.

Underlined text represents added language.

Errata Summary:

Section 310.5.1 Section 1103.2.16 Section 3411.7, Exception 1 Chapter 11 Figures – Prepared in insert page format (Pages 308 a-j)

310.5.1 Care facilities within a dwelling. Care facilities for five or fewer persons receiving care that are within a single-family dwelling are permitted to comply with the Residential Code. provided an automatic sprinkler system is installed in accordance with Section 903.3.1.3 or with Appendix T of the Residential Code.

1103.2.16 Private membership clubs and churches. In accordance with ORS 447.210(1), private membership clubs and churches that have more than one floor level and more than 4,000 square feet (372 m2) in ground area or more than one floor level and more than 20 feet (9096 mm) in height, measured from the top surface of the lowest flooring to the highest interior overhead finish of the building, are not required to be accessible.

3411.7 Alterations affecting an area containing a primary function. Where an alteration affects the accessibility to, or contains an area of primary function, the route to the primary function area shall be accessible. The accessible route to the primary function area shall include toilet facilities or drinking fountains serving the area of primary function.

Exceptions:

1. The costs of providing the accessible route are not required to exceed 20 25 percent of the costs of the alterations affecting the area of primary function. (See ORS 447.241). (2 through 5 unchanged)

2014 OSSC Errata October 16, 2014

Errata for the 2014 Oregon Structural Specialty Code First Printing

Page 2: 2014 OSSC Errata October 16, 2014 Errata for the 2014 ...aisle 9’ min. 8’ min. 9’ min. 17’ min. 36° typ. page 308d 2014 oregon structural specialty code accessibility for

This page is intentionally left blank.

Page 3: 2014 OSSC Errata October 16, 2014 Errata for the 2014 ...aisle 9’ min. 8’ min. 9’ min. 17’ min. 36° typ. page 308d 2014 oregon structural specialty code accessibility for

FIGURE 1

For SI: 1 inch = 25.4 mm.

2014 OREGON STRUCTURAL SPECIALTY CODE Page 308a

ACCESSIBILITY

PAVEMENT MARKING STENCIL

Background

C (stroke width)

A

B

Pavement Marking Background: Optional: Blue, Retro-reflective

Pavement Marking Stencil: White, Retro-reflective

LEGEND

MINIMUM

DIMENSIONS (INCHES)

A B C D E F G

28 24 3

The pavement marking stencil shall be used to designate an accessible

parking area reserved for vehicles with DMV permits.

Page 4: 2014 OSSC Errata October 16, 2014 Errata for the 2014 ...aisle 9’ min. 8’ min. 9’ min. 17’ min. 36° typ. page 308d 2014 oregon structural specialty code accessibility for

Page 308b 2014 OREGON STRUCTURAL SPECIALTY CODE

ACCESSIBILITY

FIGURE 2

For SI: 1 foot = 304.8 mm. 1 degree = 0.01745 rad.

required. See Fig. 1 for dimensions

Pavement marking

9’ Min. 8’ Min.

17’ Min.

36° TYP.

White 4” wide lines

Wheel stop (Typ)

36° 3’

4’ Angle orientation

for field layout

Full L

ength

of

Park

ing S

pace

ACCESSIBLE ROUTE

sign

locations

Curb ramp (shall not extend into the access aisle)

SIGN R7-8

SIGN R7-8 P

Opt. sign location

2’ 2’

2’ Typ

Access Aisle

MINIMUM STANDARD

SINGLE-ACCESSIBLE PARKING SPACE (VAN-ACCESSIBLE DESIGNATION REQUIRED)

Page 5: 2014 OSSC Errata October 16, 2014 Errata for the 2014 ...aisle 9’ min. 8’ min. 9’ min. 17’ min. 36° typ. page 308d 2014 oregon structural specialty code accessibility for

FIGURE 3

For SI: 1 foot = 304.8 mm, 1 degree = 0.01745.

2014 OREGON STRUCTURAL SPECIALTY CODE Page 308c

ACCESSIBILITY

SIGN R7-8

SIGN R7-8 P

ACCESSIBLE ROUTE

Opt. sign location (Typ.)

SIGN R7-8

Curb ramp (shall not extend into the access aisle)

MINIMUM STANDARD

DOUBLE-ACCESSIBLE PARKING SPACE

(ONE VAN-ACCESSIBLE DESIGNATION REQUIRED)

sign

locations locations

sign

Full L

ength

of

Park

ing S

pace

Pavement marking required. See Fig. 1 for dimensions

Angle orientation for field layout

3’

4’

36 White 4”

wide lines

Wheel stop (Typ)

2’ 2’ 2’ 2’

2’ Typ

Access Aisle

9’ Min. 9’ Min. 8’ Min.

17’ Min.

36° TYP.

Page 6: 2014 OSSC Errata October 16, 2014 Errata for the 2014 ...aisle 9’ min. 8’ min. 9’ min. 17’ min. 36° typ. page 308d 2014 oregon structural specialty code accessibility for

Page 308d 2014 OREGON STRUCTURAL SPECIALTY CODE

ACCESSIBILITY

For SI: 1 foot = 304.8 mm.

FIGURE 4

MINIMUM STANDARD

FIVE ACCESSIBLE PARKING SPACES (ONE WHEELCHAIR USER DESIGNATION REQUIRED)

SIGN R7-8

SIGN R7-8 P

SIGN OR7-8C

Opt. sign location (Typ.)

SIGN R7-8

6’ (Min) Access Aisle

Van Access Aisle 8’ min.

required. See Fig. 1 for dimensions

Pavement marking

ACCESSIBLE ROUTE

9’ Min

17’ Min.

9’ 9’ 9’ 9’ Min Min Min Min

Page 7: 2014 OSSC Errata October 16, 2014 Errata for the 2014 ...aisle 9’ min. 8’ min. 9’ min. 17’ min. 36° typ. page 308d 2014 oregon structural specialty code accessibility for

FIGURE 5

For SI: 1 inch = 25.4 mm.. 1 foot = 308.4 mm.

2014 OREGON STRUCTURAL SPECIALTY CODE Insert Facing Page 308e

ACCESSIBILITY

17”

Min

.

10’ TYP.

Van Access Aisle 8’ min.

9’ M

in.

9’ M

in.

9’ M

in.

9’ M

in.

6’ (Min) Access Aisle

CURB RAMP (TYP.)

White 24” wide lines (TYP.)*

* Type and width of crosswalk may vary from illustration. Crosswalk shall be MUTCD compliant.

VEHICULAR WAY

A raised crosswalk may be used instead of ramps at each end of the crosswalk as shown.

CURB RAMP (TYP.) CURB

MULTIPLE-ACCESSIBLE PARKING SPACE WITH

RAISED PEDESTRIAN WALKWAYS

Page 8: 2014 OSSC Errata October 16, 2014 Errata for the 2014 ...aisle 9’ min. 8’ min. 9’ min. 17’ min. 36° typ. page 308d 2014 oregon structural specialty code accessibility for

Page 308f 2014 OREGON STRUCTURAL SPECIALTY CODE

ACCESSIBILITY

FIGURE 6

For SI: 1 inch = 25.4 mm., 1 foot = 304.8 mm.

6’ (Min) Access Aisle

Van Access Aisle 8’ min.

VEHICULAR WAY White 24” wide lines (TYP.)*

* Type and width of crosswalk may vary from illustration. Crosswalk shall be MUTCD compliant.

MULTIPLE-ACCESSIBLE PARKING SPACE WITH

AT-GRADE PEDESTRIAN WALKWAYS

NO CURB

17

” M

in.

9’ M

in.

9’ M

in.

9’ M

in.

10’ TYP.

9’ M

in.

Page 9: 2014 OSSC Errata October 16, 2014 Errata for the 2014 ...aisle 9’ min. 8’ min. 9’ min. 17’ min. 36° typ. page 308d 2014 oregon structural specialty code accessibility for

FIGURE 7

For SI: 1 inch = 25.4 mm.

2014 OREGON STRUCTURAL SPECIALTY CODE Insert Facing Page 308g

ACCESSIBILITY

SIGN DESIGN SIGN NO. R7-8

12”

18”

Sign Legend: Green, Retro-reflective sheeting

Sign Background: White, Retro-reflective sheeting

The Accessible Person parking sign is used to designate a parking area reserved for vehicles with DMV permit as stated.

Symbol: White on Blue Background, Retro-reflective

Sign: Standard Federal R7-8 without arrow from

the Standards Highway and Markings Handbook

Page 10: 2014 OSSC Errata October 16, 2014 Errata for the 2014 ...aisle 9’ min. 8’ min. 9’ min. 17’ min. 36° typ. page 308d 2014 oregon structural specialty code accessibility for

Page 308h 2014 OREGON STRUCTURALSPECIALTY CODE

ACCESSIBILITY

FIGURE 8

For SI: 1 inch = 25.4 mm., 1 foot = 304.8 mm.

18”

9”

2 1/4”

2” D

1”

1 1/2” D

2 1/4”

3/8” 3/8” 1 1/2” R

SIGN DESIGN SIGN NO. R7-8P

Sign Background: White, Retroreflective sheeting

Sign Legend: Green, Retroreflective sheeting

Refer to the Standard Highway Signs book for details.

The VAN-ACCESSIBLE sign shall only be used with sign R7-8 to designate the parking spaces that have an access aisle 8 ft or wider

Page 11: 2014 OSSC Errata October 16, 2014 Errata for the 2014 ...aisle 9’ min. 8’ min. 9’ min. 17’ min. 36° typ. page 308d 2014 oregon structural specialty code accessibility for

FIGURE 9

2014 OREGON STRUCTURAL SPECIALTY CODE Insert Facing Page 308i

ACCESSIBILITY

For SI: 1 inch = 25.4 mm., 1 foot = 304.8 mm.

SIGN DESIGN SIGN NO. OR7-8c

18”

9”

2 1/4”

1 1/2”D

1 1/2”D

1 1/2”

2 1/4”

3/8” 3/8” 1 3/4”R

Sign Background: White, Retroreflective sheeting

Sign Legend: Green, Retroreflective sheeting

Refer to ODOT Sign Policy and Guidelines for details.

The WHEELCHAIR USER ONLY sign shall only be used with the Disabled Person Parking Sign (R7-8) and the VAN ACCESSIBLE sign (R7-8P) to designate the wheelchair user only spaces as defined in ORS 447.233

Page 12: 2014 OSSC Errata October 16, 2014 Errata for the 2014 ...aisle 9’ min. 8’ min. 9’ min. 17’ min. 36° typ. page 308d 2014 oregon structural specialty code accessibility for

Page 308j 2014 OREGON STRUCTURAL SPECIALTY CODE

ACCESSIBILITY

FIGURE 10

For SI: 1 inch = 25.4 mm., 1 foot = 304.8 mm.

Vertical clearance not less than 98” over entire parking & aisle area.

—-2% Slope over entire parking & aisle area

9” min 8” min

17” min

curb ramp (shall not extend into

the access aisle)

Full L

ength

of

Park

ing S

pace

ACCESSIBLE ROUTE

(Use “Parallel or Combined Ramp Detail” when reqd. landing cannot be obtained)

PENDICULAR SIDEWALK RAMP DETAIL

SECTION A—A SECTION A—A WITH MONOLITHIC CURB & SIDEWALK

Flare slopes 10% for landings 4’ or wider and 8.33% for landings between 3’ and 4’ wide

Landing (L) New Constr. 4’ min. Alterations 3’ min.

4’ Norm. 3’ min.

Gutter

0/ Lip

Gutter 0/ Lip

9” 12”

5% Max. (Typ.)

e

s - 0.02

A

A 5%

Max. 2%

Norm8.33

%

(s)

ADA RAMP AND SLOPE DESIGN