Commercial air Conditioning range
Page 18-29 Page 30-31
Page 46-51
Page 56-59
Page 76-77
Page 84-87
Page 32-37
Page 60-61
Page 78-79
Page 88-89 Page 90-91
Page 38-43
Page 62-67
Page 80-81
Page 44-45
Page 68-69
Page 52-53
Page 70-75
Aqu@FanFan coil unit
1.9 to 9 kW 2.3 to 11.6 kW
VPNFan coil unit
1.8 to 12.6 kW 3.5 to 20 kW
VHHigh static pressure ductable fan coil unit
2.1 to 28.4 kW 3.5 to 33.9 kW
WespakAir handling unit for false ceiling application
500 to 9 000 m³/h
HANRooftop unit
9.8 to 31 kW 9.6 to 30.5 kW
HRWWater source heat pump
1.9 to 30 kW 2.6 to 38 kW
Slim@airAir handling unit for false ceiling application
500 to 6 000 m³/h
RoofT@irRooftop unit
41 to 108 kW 43 to 108 kW
EWHWater source heat pump
3.9 to 43 kW 4.3 to 58 kW
CW-ARWater source heat pump
1.9 to 2.7 kW 2.4 to 3.2 kW
KCO1-way chilled water cassette
1.7 to 4.3 kW 2.3 to 6.4 kW
Eff@irAir handling unit 25-40 mm panels thick
400 to 12 000 m³/h
RoofTechRooftop unit
101 to 221 kW 97 to 220 kW
H@WairHigh wall chilled water unit
2.2 to 4.7 kW 2.9 to 5.9 kW
Premi@irAir handling unit
1 000 to 30 000 m³/h
Aqu@beamChilled beam
1.2 kW/ml 1.2 kW/ml
@irTwinAir handling unit
1 000 to 100 000 m³/h
water terminal units
air handling & rooftops units
water source heat pumps
KOG4-way chilled water cassette
2.3 to 10.2 kW 2.2 to 11.6 kW
new
new
new
new
new
new
newnew eCnew eC
4 5
Page 94-95
Page 108-111
Page 148-149
Page 158-161
Page 174-175
Page 126-133
Page 96-97
Page 112-115
Page 134-141
Page 150-151
Page 162-163
Page 98-99
Page 116-119
Page 142-143
Page 152-153
Page 164-165 Page 166-167 Page 168-169
Page 170-171 Page 172-173
Page 100-103
Page 120-123
Page 144-147
Page 154-155
Page 104-107
Page 124-125
MQHAir-to-water heat pump
5.4 to 17.8 kW 6.1 to 20.1 kW
AQVSL/AQVSHAir cooled chiller / Air-to-water heat pump
75 to 157 kW 83 to 168 kW
CDClose control air conditioning
10 to 32 kW
DK DNAir-to-air split system
12 to 83 kW 12.4 to 83.8 kW
VLCAir-cooled condensing chiller
137 to 308 kW
SLS/SLS HEAir cooled chiller
300 to 550 kW 1050 to 1650 kW
MQHDAir-to-water heat pump
1.8 to 11.8 kW 2.4 to 14.4 kW
AQVL/AQVHAir cooled chiller / Air-to-water heat pump
80 to 137 kW 92 to 146 kW
WQL/WQHWater cooled chiller / Water-to-water heat pump
21 to 193 kW 24 to 210 kW
MDClose control air conditioning
20 to 103 kW
CAOWater console
2.3 to 4.7 kW
VLS/VLHAir cooled chiller / Air-to-water heat pump
134 to 308 kW 150 to 336 kW
RWCWater cooled chiller
161 to 312 kW
CWClose control air conditioning
15 to 200 kW
X ARVertical air cabinet
8.7 to 55 kW
X AOVertical water cabinet
8.0 to 45.7 kW
CDNAir-cooled condensing chiller
19 to 83 kW
AQCAir-cooled condensing chiller
41 to 80 kW
AQVCAir-cooled condensing chiller
84 to 137 kW
Aqu@Logic AQL/AQHAir cooled chiller / Air-to-water heat pump
19.1 to 75.8 kW 18.7 to 84.9 kW
AQWL/AQWHAir cooled chiller / Air-to-water heat pump
360 to 634 kW 418 to 702 kW
SWS/SWRWater cooled chiller
272 to 1118 kW
WesthermChilled water propeller fan unit heaters
2.8 to 32.88 kW 4.82 to 197.59 kW
AQCL/AQCHAir cooled chiller / Air-to-water heat pump
25 to 125 kW
AQSLAir cooled chiller
605 to 929 kW
air cooled chillers
water cooled chillers
close control
direct expansion
water heaters
Aqu@Logic 20-30 DCIAir-to-water heat pump
19.6 to 28.8 kW 18.7 to 25.7 kW
new new
new
new
6 7
table of contents
page
airwell groUp 8
r&d 10
new prodUCts 2012 11
serviCes 14
water terminal Units 16
Aqu@Fan new eC Fan coil unit 18
VPN new Fan coil unit 30
KOG new 4-way chilled water cassette 32
KCO new eC 1-way chilled water cassette 38
H@Wair new High-wall chilled water unit 44
VH High static pressure ductable fan coil unit 46
Aqu@beam Chilled beam 52
air Handling Units 54
Wespak Air handling unit for false ceiling application 56
Slim@ir new Air handling unit for false ceiling application 60
Eff@ir new Air handling unit 62
Premi@ir Air handling unit 68
@irTwin Air handling unit 70
rooFtops 76
HAN Rooftop unit 76
RoofT@ir Rooftop unit 78
RoofTech Rooftop unit 80
water soUrCe Heat pUmps 82
HRW Water source heat pump 84
EWH new Water source heat pump 88
CW-AR new Water source heat pump 90
6 7
page
air Cooled CHillers 92
MQH Air-to-water heat pump 94
MQHD new Air-to-water heat pump 96
Aqu@Logic DCI new Air-to-water heat pump 98
Aqu@Logic AQL Air-cooled chiller 100
Aqu@Logic AQH Air-to-water heat pump 102
AQCL Air-cooled chiller 104
AQCH Air-to-water heat pump 106
AQVSL Air-cooled chiller 108
AQVSH Air-to-water heat pump 110
AQVL Air-cooled chiller 112
AQVH Air-to-water heat pump 114
VLS Air-cooled chiller 116
VLH Air-to-water heat pump 118
AQWL Air-cooled chiller 120
AQWH Air-to-water heat pump 122
AQSL new Air-cooled chiller 124
SLS STD Air-cooled chiller 126
SLS HE Air-cooled chiller 130
water Cooled CHillers 134
WQL Water-cooled chiller 134
WQH new Water-to-water heat pump 138
RWC Water-cooled chiller 142
SWS Water-cooled chiller 144
Close Control 148
CD Close-control air conditioning 148
MD Close-control air conditioning 150
CW Close-control air conditioning 152
water Heaters 154
Westherm Chilled water propeller fan unit heater 154
direCt expansion 156
DK DN Air-to-air split system 158
CAO Water console 162
X AR Vertical air cabinet 164
X AO Vertical water cabinet 166
CDN Air-cooled condensing chiller 168
AQC Air-cooled condensing chiller 170
AQVC Air-cooled condensing chiller 172
VLC Air-cooled condensing chiller 174
8 9
oUr HistorY
1947 Paul Wallet founded “L’Air Conditionné entreprise” which later became the core of Airwell Group.
1950 The Company developed and began the mass production of the first window unit, to offer exceptional climate conditions, mainly dedicated to european and African markets.
1970 Airwell developed a split system unit by splitting its core window unit in two parts, and was the first to produce wall split systems in europe.
1975 Airwell entered the commercial and industrial markets with large cooling capacity for packaged air and water-cooled systems.
1979 After the two oil crises in the 70s Airwell developed the first high-efficiency air to water heatpump to be connected to existing oil boilers in residential housing for oil energy saving.
1982 Airwell designed and produced the first european wall split system range including electronic remote control, a high technology cross-flow fan for low noise levels, and rotary compressors.
1993/1996The Group grew with the acquisition of Spanish, Italian, German and French distribution companies, as well as the factory in Tillieres.
airwell Group
Founded in 1947, Airwell Group is one of the globally leading manufacturers and distributors of air conditioners and central air conditioning systems. The company has production facilities and marketing subsidiaries worldwide.
8 9
1998/2001 The Group strengthened its position by acquiring production facilities in China, France (Airwell) and Italy, and extended its distribution network in Argentina and Turkey.
2004/2006In order to accentuate its position in the market, the Group opened an office in Russia and acquired Polenz Klimatechnik in Germany.
2008The Group reinforced its position in the American continent by acquiring the Fedders Residential Business (USA).
expertise
Over 60 years of experience in the design, development and production of residential, commercial and industrial applications make Airwell Group an indispensable actor on the european market. References are numerous in France and internationally and concern all sectors of activity including many hospitals (operating rooms, white rooms...) industrial sites, energy-efficient office buildings, hotels, and also under naval board. Our sales department will be able to illustrate our references according to your requests.
oFFiCes
sH
opping Centers
Hostels HealtH indUstrY navY
10 11
environment
HeatreCoverY
plUg& plaY
energYsaving
innovation & qUalitYInnovation and Quality are one important parts of Airwell’s philosophy. Spending all our energy to continuously develop innovative products for our customer will ensure our market position. More than 130 people are devoted to study products with a special are to the energy efficiency and acoustic emission issues for a better quality of life.
CertiFiCationsThe company plants are ISO 9001 certified by most recognised certification bodies and participates in the renowned eurovent Certification program, a voluntary initiative which ensures that capacity ratings and design properties have been verified by independent laboratories according to international standards.
teCHnologY & environmentAirwell’s primary objective is to design and offer air conditioning systems that meet both the highest standards of environmental protection and users’ legitimate expectations in terms of comfort and wellbeing. For Airwell, innovation has to be linked tightly to a respect for the environment and must include stringent requirements in terms of quality levels. This ongoing concern governs all our actions and involves all our human and technological resources. In accordance with this principle and with european Directives, in its appliances, Airwell uses ecological refrigerant fluids of the HFC type (R410A & R407C) that do not harm the planet’s ozone layer. Moreover, with a constant care for participating in preserving the environment, Airwell designs and markets high efficiency products that reduce CO2 emissions into the atmosphere and minimize our contribution to global warming.
r&d
10 11
new products 2012
Aqu@Fan II 20-60 EC Fan coil unit cooling capacity: from 1.9 to 5.7 kW Heating capacity: from 2.3 to 7.4 kW Sizes: 5 Vertical or horizontal, with or without cabinet
MAIN FeATUReS: low consumption Ec fan Energy class a or B low noise level Hydrophilic coil
KCO LN EC1-Way coanda caSSEttE cooling capacity: from 1.7 to 4.3 kW Heating capacity: from 2.3 to 6.4 kW Sizes: 3
MAIN FeATUReS: low consumption Ec fan Extra low noise level aesthetic metal grille optimized air diffusion with coanda effect
KOG LN DESIGN4-Way cHillEd WatEr caSSEttE cooling capacity: from 2.3 to 4.6 kW Heating capacity: from 2.2 to 5.7 kW Sizes: 3
MAIN FeATUReS: aesthetic metal grille 4-way air diffusion with coanda effect
choice of 192 colours integrated valve and control
KOG LN EC4-Way cHillEd WatEr caSSEttE cooling capacity: from 2.3 to 4.6 kW Heating capacity: from 2.2 to 5.7 kW Sizes: 3
MAIN FeATUReS: low consumption Ec fan Extra low noise level Hydrophilic coil integrated valve and control
VPNFan coil unit cooling capacity: from 1.8 to 12.6 kW Heating capacity: from 3.5 to 20.0 kW Sizes: 9 Versions: 2-Pipes & 2-Pipes/2-Wires Horizontal concealed
MAIN FeATUReS: High airflow Hydrophilic coil Extended drain pan
H@WairHigH-Wall cHillEd WatEr unit cooling capacity: from 2.2 to 4.7 kW Heating capacity: from 2.9 to 5.9 kW Sizes: 4
MAIN FeATUReS: aesthetic design ir control or wall-mounted thermostat
With or without thermostat
Motorized flap
p. 20-21-24-25
p. 34-35
p. 40-41
p. 30-31
p. 34-35
p. 44-45
12 13
EWHWatEr SourcE HEat PuMP
cooling capacity: from 3.9 to 43 kW Heating capacity: from 4.3 to 58 kW refrigerant: r410a Sizes: 11 models, 7 casings Horizontal concealed installation
MAIN FeATUReS: High coP Fitted with high protection low sound level
CW-ARVErtical WatEr-SourcE HEat PuMP
cooling capacity: from 1.9 to 2.7 kW Heating capacity: from 2.4 to 3.2 kW refrigerant: r407c Sizes: 3 console or concealed
MAIN FeATUReS: High efficiency low noise low consumption Ec fan Electronic control
Slim@ir 0303 to 0318air Handling unit
airflow: from 500 to 6 000 m3/h. number of models: 6. accessibility: side or bottom. orientation: horizontal or vertical. configuration: in line, superposed or side by side. installation: false-ceiling, false-floor, wall, outdoor. Finishing: precoated, galvanised or stainless steel. insulation: glass wool or rock wool. total accessibility!
Eff@irair Handling unit
Performance from 50 to 93%. 400 to 12 000 m3/h. 3 heat recovery possibilities: heat plate exchanger, wheel, counter flow plate heat exchanger.
control on board.
new products 2012
p. 60-61
p. 88-89
p. 62 to 67
p. 90-91
12 13
AQSL 2612-4212air-coolEd cHillEr
cooling capacity: from 605 to 926 kW refrigerant: r134a Sizes: 7
MAIN FeATUReS: 2 semi-hermetic screw compressors/2 independent refrigerant circuits class a High efficiency pure counter-flow Shell & tube evaporator top class EEr and ESEEr Partial (optional desuperheater) or total heat recovery (aQSr model)
WQH 20-190WatEr-to-WatEr HEat PuMP
cooling capacity: from 21 to 186 kW Heating capacity: from 24 to 210 kW refrigerant: r410a Sizes: 14
MAIN FeATUReS: Single scroll compressors class B compact design Hydrokit for source and user sides (optional)
Production of dHW
ACOUSTIC OPTIONS: Bln Base low noise Eln Extra low noise
MQHD 06-08-10air-to-WatEr HEat PuMP
Heating capacity: from 1.8 to 11.8 kW cooling capacity: from 2.4 to 14.4 kW refrigerant: r410a
MAIN FeATUReS: compressor inverter Management of domestic hot water leaving water temperature up to 55°c coP up to 4
Aqu@Logic DCI 20-25-30 air-to-WatEr HEat PuMP
Heating capacity: from 18.7 to 25.7 kW cooling capacity: from 19.6 to 28.8 kW refrigerant: r410a
MAIN FeATUReS: Scroll compressor inverter class a Management of domestic hot water
leaving water temperature up to 55°c
coP up to 4.13 EEr up to 5.01
p. 96-97
p. 124-125
p. 98-99
p. 138 to 141
14 15
training For CUstomer’s knowledgeFor Airwell CAC activity, customers who have a good knowledge of technical characteristics of our products, this is the insurance of well-made installations which will last for years! Training are proposed on a regularly basis during installations and start-up in order to give them all technical tools useful to monitor our machines.For After Sales Technical Service companies (ASTS), training is more focused on commissioning and maintenance operations: they are mainly organised on site by Airwell CAC technical experts during installation start-ups. Usually training programs are about regulation and hydraulic or refrigeration characteristics.
efficient services for quality follow-up
To answer to all questions that can ask our customers, from installation, start-up and maintenance of all our ranges of machines, Airwell CAC activity has implemented service with a high level of quality.
Customer’s satisfaction and an answer to all his requests about our products represent our first priority. In this way, Airwell CAC activity is committed to a continuous improvement of its service to professional customers, actions oriented around 3 main axes: training, spare parts and technical support.
14 15
spare parts: tHe optimal reaCtivitYProviding spare parts from Airwell origin is critical for good reliability and long life of our machines. That is why we have installed our european spare parts centre in France in Tillières (100 km West from Paris) on a factory site. With more than 12 000 references in stock and very professional teams dedicated to customer service, we can deliver parts in europe within 2 to 3 days after validating customer order (depending on the availability and specific constraints linked to the weight and size of the component).
Spare parts department could be reached by: Fax: +33 (0)2 32 32 50 33; Letter at following address:AIRWeLL France SAS, Spare Parts Department, Route de Verneuil, 27570 Tillières sur Avre, FRANCe; e-mail: [email protected]
a teCHniCal sUpport able to answer to all reqUestsOn the French territory Airwell CAC business has a network of more than 10 ASTS companies with a good knowledge of our products and trained on a regularly basis. They are able to provide service like start-up for all machines of our professional product range like chillers, rooftops, Heat pump…In the meantime, we offer for our French and export customers a technical phone support given by our Technical after sales experts for all questions relative to installation, commissioning or maintenance. For French customers they are available at following number: 0891 700 407 from 8.30 AM to 12.30 PM and from 2 PM to 5 PM, from Monday to Friday.For export customers, you have to dial +33 5 46 92 32 77.For any specific question which requires a deeper expertise, we are able to arrange a travel on site by one of out technical expert in after sales in order to study with the installer the main causes of the request and the solution to be implemented.
16
Commercial Air Conditioning |
17
InnovatIon and easy InstallatIon
Design façade to meet architectural requirements
Control ready-to-install
Blue fin coils on all terminal range for efficient and hygienic solution
Cost-optimized 3-speed setting for EC fan
Easy setting of installation without dismantling
Play diffuser with grill on hinges
wat
er t
erm
ina
ls R
An
Ge a solution suitable for
all applications
WATER TERMINALS
Aqu@Fan KOGVPN KCO H@Wair VH Aqu@beam
Residential
Offices
Shopping centers
Hostels
Health
Industry
Tertiary
NEW:
oN stock!*[ ][ ] NEW:
oN stock!*[ ][ ]
* Cf. Aqu@Fan p19, 21, 23, 25 - KOG p33.
16 17
a large range of terminal units dedicated to energy saving and comfort:
Low consumption solution with: High efficiency fan motor available on fan coil, ducted fan coil and cassette range
High level of energy performance with mainly Energy class A or B
Same thermal performance as with AC fan motor
Silence Optimized fan speed staging for new low noise versions
Reinforced acoustical insulation Profiled air diffuser
Wide range of control for ultimate comfort
Factory Facilities dedicated to Flexibility and quality
Many factory-mounted options or accessories: Control Valve Air diffuser Condensate drain pump
Products fully customized to satisfy your requirements: Choice of service side for hydraulic and electric connection Version with or without cabinet On-board control
100% units are tested electrically and acoustically.
Airwell Group is engaged in a permanent research of energy saving on and all around his product range.
This logo is the witness of this voluntary gait in terms of:
Engagement
Efficiency
Energy
18
Commercial Air Conditioning |
19
Aqu@Fan AWC/AHC STD Fan coil unit - cooling and HEating
cooling capacity: from 1.9 to 9.0 kW Heating capacity: from 2.3 to 11.6 kW Sizes: 7
VeRSIONS: 2-Pipes 2-Pipes/2-Wires 4-pipes
CONFIGURATIONS: Vertical console with cabinet ceiling exposed with cabinet
PRODUCT ADVANTAGES Ease of installation. Harmonuous and aesthetic ral9010 painted cabinet design. Streamlined design and elaborate finish enabling harmonious integration. 5-speed ac fan motor. Very low operating acoustical levels. airflow rate between 140 and 1400 m³/h. Selection of service side. coil with hydrophilic fins to improve the condensate flow.
MAIN OPTIONS 3-row coil for optimized cooling performances. Electrical heater with inserted heating rod - 4 heating capacity available per model. 2-stage heater available with aqu@net control. ac motor. Selection of 3 speed. large choice of control: Electro-mechanic, electronic, on-board or wall-mounted. ModBus communication interface board. 2-way or 3-way on/oFF valve. g2 filter. Front or bottom air intake configuration. Motorized or manual fresh air damper. auxiliary condensate drain pan. condensate drain pump. Fuse holder.
MAIN ACCESSORIES Valve. control. Electrical heater. drain pan. condensate drain pump.
SElECTION SOFTWARE Win’r iii.
Operating limit fOr Standard unit
Minimum water temperature +5°C
Maximum water temperature +90°C
Maximum operating pressure 17 bars
Minimum indoor air temperature (room/intake/around unit) 5°C/15% RH
Maximum indoor air temperature (room/intake/around unit) 32°C/70% RH
18 19
aqu@fan ii size 20 30 40 50 60 70 80CAPACITIES - 2-PIPE
cooling (1)
total cooling capacity W 1870 2440 3460 4220 5730 7210 9040
Sensible capacity W 1480 1940 2730 2980 3850 5640 6890
Water flow l/h 321 418 594 725 983 1243 1548
Water pressure drop kPa 8 16 33 29 42 25 39
Heating (2) Heating capacity W 2530 3400 4570 5410 7360 9180 11300
CAPACITIES - 4-PIPE
cooling (1)
total cooling capacity W 1970 2390 3400 4220 5610 7120 8830
Sensible capacity W 1520 1880 2660 3000 3770 5540 6710
Water flow l/h 338 411 583 724 961 1228 1516
Water pressure drop kPa 42 15 31 20 40 24 38
Heating (3)
Heating capacity W 2320 3340 4540 5250 6060 6980 11600
Water flow l/h 204 292 398 460 531 611 1014
Water pressure drop kPa 6 13 25 50 15 24 48SOUND LEVELS (LS/MS/HS)
Sound power level dB(A) 34/43/53 37/48/56 37/42/52 37/45/55 43/52/61 46/54/65 49/56/66
Sound pressure level (4) dB(A) 26/35/45 29/40/48 29/34/44 29/37/47 35/44/53 38/46/57 41/48/58
nr (4) dB(A) 22/31/41 24/36/44 24/29/39 23/33/43 31/39/48 34/41/52 36/44/54FANS (LS/MS/HS)
number 1 1 2 2 2 2 3
airflow m³/h 132/223/317 181/290/407 295/385/570 333/471/736 468/650/917 545/799/1150 665/934/1376ELECTRICAL (LS/MS/HS)
Power supply V/Ph/Hz 230/1/50
Fan consumption W 16/27/45 24/40/60 33/39/57 39/45/66 41/64/107 92/110/150 90/112/188
Electrical heater (max) W 900 1200 2000 2400 3000 3000 -
WATER CONNECTIONS
type Gas Female Threaded
cooling coil inches 1/2"
Heating coil inches 1/2"
DIMENSIONS
lxWxH mm 768x478x231 953x478x231 1138x478x231 1323x478x231 1508x478x231 1323x578x231 1508x578x231WEIGHT
unit weight kg 20 23 30 35 39 42 50
(1) According to eurovent standard: Air: 27°C DB/19°C WB, Water in: 7°C/12°C.(2) According to eurovent standard: Air: 20°C, Water in: 50°C, same water flow as in cooling.(3) According to eurovent standard: Air: 20°C, Water in: 70°C/60°C.(4) Sound pressure for console unit considering a local of 100 m³, a reverberation time of 0,5 sec and a distance of 1 m.
AQU@FAN II 20 30 40 50 60 70 80
2 Pipes - 3 rows coil + g2 air filter
aWc Availability D + 7 D + 7 D + 7 D + 7 D + 7 D + 7 D + 15
aHc Availability D + 7 D + 7 D + 7 D + 7 D + 7 D + 7 D + 15
4 Pipes - 3 rows cooling coil + g2 air filter
aWc Availability D + 7 D + 7 D + 7 D + 7 D + 7 D + 7 D + 15
aHc Availability D + 7 D + 7 D + 7 D + 7 D + 7 D + 7 D + 15
Standard delivery leadtime for unit without options. List of options is available page 26. List of accessories is available page 28.
NEW: ON STOCK! configuration: 2 or 4-pipes, terminal block, without valve, left service side. accessories for customization on site also available on stock - See page 29.
AQU@FAN II 20 30 40 50 60
2Pipe Without valve aWc/aHc Code 7OG033131 7OG033132 7OG033133 7OG033134 7OG0331354Pipe Without valve aWc/aHc Code 7OG033141 7OG033142 7OG033143 7OG033144 7OG033145
availability 72h 72h 72h 72h 72h
20
Commercial Air Conditioning |
21
Aqu@Fan AWC/AHC EC Fan coil unit - cooling and HEating
cooling capacity: from 1.9 to 5.7 kW Heating capacity: from 2.3 to 7.4 kW Sizes: 5
VeRSIONS: 2-Pipes 2-Pipes/2-Wires 4-pipes
CONFIGURATIONS: Vertical console with cabinet ceiling exposed with cabinet
PRODUCT ADVANTAGES Ease of installation. Harmonuous and aesthetic ral9010 painted cabinet design. Streamlined design and elaborate finish enabling harmonious integration. low consumption Ec fan motor. Very low operating acoustical levels. airflow rate between 140 and 900 m³/h. Selection of service side. coil with hydrophilic fins to improve the condensate flow.
MAIN OPTIONS 3-row coil for optimized cooling performances. Electrical heater with inserted heating rod - 4 heating capacity available per model. 2-stage heater available with aqu@net control. Ec motor. Selection of 3 speed with Ecospeed3 board. large choice of control: Electro-mechanic, electronic, on-board or wall-mounted. ModBus communication interface board. 2-way or 3-way on/oFF valve. g2 filter. Front or bottom air intake configuration. Motorized or manual fresh air damper. auxiliary condensate drain pan. condensate drain pump.
MAIN ACCESSORIES Valve. control. Electrical heater. drain pan. condensate drain pump.
SElECTION SOFTWARE Win’r iii.
Operating limit fOr Standard unit
Minimum water temperature +5°C
Maximum water temperature +90°C
Maximum operating pressure 17 bars
Minimum indoor air temperature (room/intake/around unit) 5°C/15% RH
Maximum indoor air temperature (room/intake/around unit) 32°C/70% RH
new
20 21
aqu@fan ii size 20 30 40 50 60CAPACITIES - 2-PIPE
cooling (1)
total cooling capacity W 1870 2440 3460 4220 5730Sensible capacity W 1480 1940 2730 2980 3850
Water flow l/h 321 418 594 725 983Water pressure drop kPa 8 16 33 29 42
Heating (2) Heating capacity W 2530 3400 4570 5410 7360CAPACITIES - 4-PIPE
cooling (1)
total cooling capacity W 1970 2390 3400 4220 5610Sensible capacity W 1520 1880 2660 3000 3770
Water flow l/h 338 411 583 724 961Water pressure drop kPa 42 15 31 20 40
Heating (3)
Heating capacity W 2320 3340 4540 5250 6060Water flow l/h 204 292 398 460 531
Water pressure drop kPa 6 13 25 50 15SOUND LEVELS (LS/MS/HS)
Sound power level dB(A) 34/43/53 37/48/56 37/42/52 37/45/55 43/52/61Sound pressure level (4) dB(A) 26/35/45 29/40/48 29/34/44 29/37/47 35/44/53
nr (4) dB(A) 22/31/41 24/36/44 24/29/39 23/33/43 31/39/48FANS (LS/MS/HS)
number 1 1 2 2 2airflow m³/h 132/223/317 181/290/407 295/385/570 333/471/736 468/650/917
ELECTRICAL (LS/MS/HS)Power supply V/Ph/Hz 230/1/50
Fan consumption W 5/12/27 10/20/33 7/15/35 8/19/45 18/30/72Electrical heater (max) W 900 1200 2000 2400 3000
WATER CONNECTIONS type Gas Female Threaded
cooling coil inches 1/2" Heating coil inches 1/2"
DIMENSIONS lxWxH mm 768x478x231 953x478x231 1138x478x231 1323x478x231 1508x478x231
WEIGHT unit weight kg 20 23 30 35 39
(1) According to eurovent standard: Air: 27°C DB/19°C WB, Water in: 7°C/12°C.(2) According to eurovent standard: Air: 20°C, Water in: 50°C, same water flow as in cooling.(3) According to eurovent standard: Air: 20°C, Water in: 70°C/60°C.(4) Sound pressure for console unit considering a local of 100 m³, a reverberation time of 0,5 sec and a distance of 1 m.
AQU@FAN II 20 30 40 50 60
2 Pipes - 3 rows coil + g2 air filter
aWc Ec Availability D + 15 D + 15 D + 15 D + 15 D + 15aHc Ec Availability D + 15 D + 15 D + 15 D + 15 D + 15
4 Pipes - 3 rows cooling coil + g2 air filter
aWc Ec Availability D + 15 D + 15 D + 15 D + 15 D + 15aHc Ec Availability D + 15 D + 15 D + 15 D + 15 D + 15
Standard delivery leadtime for unit without options. List of options is available page 26. List of accessories is available page 28.
22
Commercial Air Conditioning |
23
Aqu@Fan AWN/AHN STD Fan coil unit - cooling and HEating
cooling capacity: from 1.9 to 9.0 kW Heating capacity: from 2.3 to 11.6 kW Sizes: 7
VeRSIONS: 2-Pipes 2-Pipes/2-Wires 4-pipes
CONFIGURATIONS: Vertical concealed without cabinet ceiling concealed without cabinet
PRODUCT ADVANTAGES Ease of installation. 5-speed ac fan motor. Very low operating acoustical levels. airflow rate between 140 and 1400 m³/h. Selection of service side. coil with hydrophilic fins to improve the condensate flow.
MAIN OPTIONS 3-row coil for optimized cooling performances. Electrical heater with inserted heating rod - 4 heating capacity available per model. 2-stage heater available with aqu@net control. ac motor. Selection of 3 speed. large choice of control: Electro-mechanic, electronic, on-board or wall-mounted. ModBus communication interface board. 2-way or 3-way on/oFF valve. g2 filter. Various air intake configuration. ducted plenum for air intake or dischage. Motorized or manual fresh air damper. auxiliary condensate drain pan. condensate drain pump.
MAIN ACCESSORIES Valve. control. Electrical heater. drain pan. condensate drain pump. choice of ducted plenum for air intake or dischage.
SElECTION SOFTWARE Win’r iii.
Operating limit fOr Standard unit
Minimum water temperature +5°C
Maximum water temperature +90°C
Maximum operating pressure 17 bars
Minimum indoor air temperature (room/intake/around unit) 5°C/15% RH
Maximum indoor air temperature (room/intake/around unit) 32°C/70% RH
22 23
aqu@fan ii size 20 30 40 50 60 70 80CAPACITIES - 2-PIPE
cooling (1)
total cooling capacity W 1870 2440 3460 4220 5730 7210 9040
Sensible capacity W 1480 1940 2730 2980 3850 5640 6890
Water flow l/h 321 418 594 725 983 1243 1548
Water pressure drop kPa 8 16 33 29 42 25 39
Heating (2) Heating capacity W 2530 3400 4570 5410 7360 9180 11300
CAPACITIES - 4-PIPE
cooling (1)
total cooling capacity W 1970 2390 3400 4220 5610 7120 8830
Sensible capacity W 1520 1880 2660 3000 3770 5540 6710
Water flow l/h 338 411 583 724 961 1228 1516
Water pressure drop kPa 42 15 31 20 40 24 38
Heating (3)
Heating capacity W 2320 3340 4540 5250 6060 6980 11600
Water flow l/h 204 292 398 460 531 611 1014
Water pressure drop kPa 6 13 25 50 15 24 48
SOUND LEVELS (LS/MS/HS)
Sound power level dB(A) 34/43/53 37/48/56 37/42/52 37/45/55 43/52/61 46/54/65 49/56/66
Sound pressure level (4) dB(A) <15/24/32 16/27/35 16/21/31 16/24/34 22/31/40 27/35/44 28/35/45
nr (4) dB(A) <15/19/28 <15/23/31 <15/16/26 <15/20/30 18/26/35 23/30/39 23/31/41
FANS (LS/MS/HS)
number 1 1 2 2 2 2 3
airflow m³/h 132/223/317 181/290/407 295/385/570 333/471/736 468/650/917 545/799/1150 665/934/1376
ELECTRICAL (LS/MS/HS)
Power supply V/Ph/Hz 230/1/50
Fan consumption W 16/27/45 24/40/60 33/39/57 39/45/66 41/64/107 92/110/150 90/112/188
Electrical heater (max) W 900 1200 2000 2400 3000 3000 -
WATER CONNECTIONS
type Gas Female Threaded
cooling coil inches 1/2"
Heating coil inches 1/2"
DIMENSIONS
lxWxH mm 510x430x220 695x430x220 880x430x220 1065x430x220 1250x430x220 1065x530x220 1250x530x220
WEIGHT
unit weight kg 20 23 30 35 39 42 50
(1) According to eurovent standard: Air: 27°C DB/19°C WB, Water in: 7°C/12°C.(2) According to eurovent standard: Air: 20°C, Water in: 50°C, same water flow as in cooling.(3) According to eurovent standard: Air: 20°C, Water in: 70°C/60°C.(4) Sound pressure for console unit considering a local of 100 m³, a reverberation time of 0,5 sec and a distance of 1 m.
AQU@FAN II 20 30 40 50 60 70 80
2 Pipes - 3 rows coil + g2 air filter
aWn Availability D + 7 D + 7 D + 7 D + 7 D + 7 D + 7 D + 15
aHn Availability D + 7 D + 7 D + 7 D + 7 D + 7 D + 7 D + 15
4 Pipes - 3 rows cooling coil + g2 air filter
aWn Availability D + 7 D + 7 D + 7 D + 7 D + 7 D + 7 D + 15
aHn Availability D + 7 D + 7 D + 7 D + 7 D + 7 D + 7 D + 15
Standard delivery leadtime for unit without options. List of options is available page 26. List of accessories is available page 28.
NEW: ON STOCK! configuration: 2 or 4-pipes, terminal block, without valve, left service side. accessories for customization on site also available on stock - See page 29.
AQU@FAN II 20 30 40 50 60
2Pipe Without valve aWn/aHn Code 7OG033136 7OG033137 7OG033138 7OG033139 7OG0331404Pipe Without valve aWn/aHn Code 7OG033146 7OG033147 7OG033148 7OG033149 7OG033150
availability 72h 72h 72h 72h 72h
24
Commercial Air Conditioning |
25
Aqu@Fan AWN/AHN EC Fan coil unit - cooling and HEating
cooling capacity: from 1.9 to 5.7 kW Heating capacity: from 2.3 to 7.4 kW Sizes: 5
VeRSIONS: 2-Pipes 2-Pipes/2-Wires 4-pipes
CONFIGURATIONS: Vertical concealed without cabinet ceiling concealed without cabinet
PRODUCT ADVANTAGES Ease of installation. low consumption Ec fan motor. Very low operating acoustical levels. airflow rate between 140 and 900 m³/h. Selection of service side. coil with hydrophilic fins to improve the condensate flow.
MAIN OPTIONS 3-row coil for optimized cooling performances. Electrical heater with inserted heating rod - 4 heating capacity available per model. 2-stage heater available with aqu@net control. Ec motor. Selection of 3 speed with Ecospeed3 board. large choice of control: Electro-mechanic, electronic, on-board or wall-mounted. ModBus communication interface board. 2-way or 3-way on/oFF valve. g2 filter. Front or bottom air intake configuration. ducted plenum for air intake or dischage. Motorized or manual fresh air damper. auxiliary condensate drain pan. condensate drain pump.
MAIN ACCESSORIES Valve. control. Electrical heater. drain pan. condensate drain pump. choice of ducted plenum for air intake or dischage.
SElECTION SOFTWARE Win’r iii.
Operating limit fOr Standard unit
Minimum water temperature +5°C
Maximum water temperature +90°C
Maximum operating pressure 17 bars
Minimum indoor air temperature (room/intake/around unit) 5°C/15% RH
Maximum indoor air temperature (room/intake/around unit) 32°C/70% RH
new
24 25
aqu@fan ii size 20 30 40 50 60CAPACITIES - 2-PIPE
cooling (1)
total cooling capacity W 1870 2440 3460 4220 5730
Sensible capacity W 1480 1940 2730 2980 3850
Water flow l/h 321 418 594 725 983
Water pressure drop kPa 8 16 33 29 42
Heating (2) Heating capacity W 2530 3400 4570 5410 7360
CAPACITIES - 4-PIPE
cooling (1)
total cooling capacity W 1970 2390 3400 4220 5610
Sensible capacity W 1520 1880 2660 3000 3770
Water flow l/h 338 411 583 724 961
Water pressure drop kPa 42 15 31 20 40
Heating (3)
Heating capacity W 2320 3340 4540 5250 6060
Water flow l/h 204 292 398 460 531
Water pressure drop kPa 6 13 25 50 15
SOUND LEVELS (LS/MS/HS)
Sound power level dB(A) 34/43/53 37/48/56 37/42/52 37/45/55 43/52/61
Sound pressure level (4) dB(A) <15/24/32 16/27/35 16/21/31 16/24/34 22/31/40
nr (4) dB(A) <15/19/28 <15/23/31 <15/16/26 <15/20/30 18/26/35
FANS (LS/MS/HS)
number 1 1 2 2 2
airflow m³/h 132/223/317 181/290/407 295/385/570 333/471/736 468/650/917
ELECTRICAL (LS/MS/HS)
Power supply V/Ph/Hz 230/1/50
Fan consumption W 5/12/27 10/20/33 7/15/35 8/19/45 18/30/72
Electrical heater (max) W 900 1200 2000 2400 3000
WATER CONNECTIONS
type Gas Female Threaded
cooling coil inches 1/2"
Heating coil inches 1/2"
DIMENSIONS
lxWxH mm 510x430x220 695x430x220 880x430x220 1065x430x220 1250x430x220
WEIGHT
unit weight kg 14 16 23 27 30
(1) According to eurovent standard: Air: 27°C DB/19°C WB, Water in: 7°C/12°C.(2) According to eurovent standard: Air: 20°C, Water in: 50°C, same water flow as in cooling.(3) According to eurovent standard: Air: 20°C, Water in: 70°C/60°C.(4) Sound pressure for console unit considering a local of 100 m³, a reverberation time of 0,5 sec and a distance of 1 m.
AQU@FAN II 20 30 40 50 60
2 Pipes - 3 rows coil + g2 air filter
aWn Ec Availability D + 15 D + 15 D + 15 D + 15 D + 15aHn Ec Availability D + 15 D + 15 D + 15 D + 15 D + 15
4 Pipes - 3 rows cooling coil + g2 air filter
aWn Ec Availability D + 15 D + 15 D + 15 D + 15 D + 15aHn Ec Availability D + 15 D + 15 D + 15 D + 15 D + 15
Standard delivery leadtime for unit without options. List of options is available page 26. List of accessories is available page 28.
26
Commercial Air Conditioning |
27
OPTIONS AVAILAbILITy
20 30 40 50 60 70 80 MP Support feet for AWC D+7 D+7 D+7 D+7 D+7 D+7 D+7
MPg Grille between feet for AWC (MP included) D+15 D+15 D+15 D+15 D+15 D+15 D+15
BacAuxiliary drain pan for AWC/AWN D+7 D+7 D+7 D+7 D+7 D+7 D+7
Auxiliary drain pan for AHC/AHN D+7 D+7 D+7 D+7 D+7 D+7 D+7
crg Discharge duct collar for AWN/AHN (Mini qty: 10) D+15 D+15 D+15 D+15 D+15 D+15 D+15
Prc Drain pump D+15 D+15 D+15 D+15 D+15 D+15 D+15
OPTIONS AVAILAbILITy
air side 20 30 40 50 60 70 80 rF RF AMOV Front air intake (with grill) D+15 D+15 D+15 D+15 D+15 D+15 D+15
rd Front air intake for AWN D+15 D+15 D+15 D+15 D+15 D+15 D+15
Front air intake for AHN D+15 D+15 D+15 D+15 D+15 D+15 D+15
rP Back partial air intake with support feet for AWC/AHC D+15 D+15 D+15 D+15 D+15 D+15 D+15
rVca-rt Air intake arrangement with motorized (non controlled) on/off damper (back or/and front intake) D+15 D+15 D+15 D+15 D+15 D+15 D+15
rVca-rc Air intake arrangement with motorized (non controlled) on/off damper (floor or/and front intake) D+15 D+15 D+15 D+15 D+15 D+15 D+15
rVcM-rt Air intake arrangement with manual damper (back or/and front intake) D+15 D+15 D+15 D+15 D+15 D+15 D+15
rVcM-rc Air intake arrangement with manual damper (floor or/and front intake) D+15 D+15 D+15 D+15 D+15 D+15 D+15
PlEnuM aPS
Discharge plenum with duct 1 x 200 mm D+15 D+15 - - - - -
Discharge plenum with duct 1 x 250 mm Ob - D+15 D+15 D+15 - D+15 -
Discharge plenum with duct 2 x 200 mm - - D+15 D+15 - D+15 -
Discharge plenum with duct 3 x 200 mm - - - - D+15 D+15 D+15
Discharge plenum with duct 3 x 250 mm Ob - - - - D+15 - D+15
PlEnuM aPSa
Return & Discharge plenum with duct 1 x 200 mm D+15 D+15 - - - - -
Return & Discharge plenum with duct 1 x 250 mm Ob - D+15 D+15 D+15 - D+15 -
Return & Discharge plenum with duct 2 x 200 mm - - D+15 D+15 - D+15 -
Return & Discharge plenum with duct 3 x 200 mm - - - - D+15 D+15 D+15
Return & Discharge plenum with duct 3 x 250 mm Ob - - - - D+15 - D+15
OPTIONS AVAILAbILITy
230 v thermal type on/off valve (1) 20 30 40 50 60 70 80
aWc aWn
2-way type, one valve for one coil - W2G1 D+7 D+7 D+7 D+7 D+7 D+7 D+7
2-way type, two valves for two coils - W2G2 D+7 D+7 D+7 D+7 D+7 D+7 D+7
4-way type, one valve for one coil - W4G1 D+7 D+7 D+7 D+7 D+7 D+7 D+7
4-way type, two valves for two coils - W4G2 D+7 D+7 D+7 D+7 D+7 D+7 D+7
aHc aHn
2-way type, one valve for one coil - W2G1 D+7 D+7 D+7 D+7 D+7 D+7 D+7
2-way type, two valves for two coils - W2G2 D+7 D+7 D+7 D+7 D+7 D+7 D+7
4-way type, one valve for one coil - W4G1 D+7 D+7 D+7 D+7 D+7 D+7 D+7
4-way type, two valves for two coils - W4G2 D+7 D+7 D+7 D+7 D+7 D+7 D+7
options
26 27
OPTIONS AVAILAbILITy
electrical heater 20 30 40 50 60 70 80300w D+15 D+15 - - - - -
500w - - D+15 - - - -
600w D+15 D+15 - D+15 - - -
750w - - - - D+15 D+15 -
900w D+15 D+15 - - - - -
1000w - - D+15 - - - -
1200w - D+15 - D+15 - - -
1500w - - D+15 - D+15 D+15 -
1800w - - - D+15 - - -
2000w - - D+15 - - - -
2250w - - - - D+15 D+15 -
2400w - - - D+15 - - -
3000w - - - - D+15 D+15 -
OPTIONS AVAILAbILITy
regulation option 20 30 40 50 60 70 80Terminal block D+7 D+7 D+7 D+7 D+7 D+7 D+7
Eco3 Ecospeed card for EC Motor D+15 D+15 D+15 D+15 D+15 D+15 D+15
cMV Fan speed selector for mounting on unit D+15 D+15 D+15 D+15 D+15 D+15 D+15
tBV Bulb thermostat for mounting on unit - action on control valve and fan D+15 D+15 D+15 D+15 D+15 D+15 D+15
tBMV Bulb thermostat with summer/winter manual switch for mounting on unit - action on control valve and fan D+15 D+15 D+15 D+15 D+15 D+15 D+15
Pco Mechanical sensor for automatique change over D+7 D+7 D+7 D+7 D+7 D+7 D+7
aQuanEt
Aquanet for 2 pipes unit D+7 D+7 D+7 D+7 D+7 D+7 D+7
Aquanet for 2 pipes with electrical heater unit D+7 D+7 D+7 D+7 D+7 D+7 D+7
Aquanet for 4 pipes unit D+7 D+7 D+7 D+7 D+7 D+7 D+7
niu µBMS compatible communication board NIU for Aquanet D+7 D+7 D+7 D+7 D+7 D+7 D+7
Eniu Modbus communication board eNIU for Aquanet D+7 D+7 D+7 D+7 D+7 D+7 D+7
rcl RCl remote control (mounted on AWC) D+7 D+7 D+7 D+7 D+7 D+7 D+7
28
Commercial Air Conditioning |
29
ACCESSORIES (SUPPLIED LOOSE) 20 30 40 50 60 70 80
MPSupport feet for AWC Kit code 7ACTl0391 7ACTl0391 7ACTl0391 7ACTl0391 7ACTl0391 7ACTl0391 7ACTl0391 Support feet for AWN Kit code 7ACTl0415 7ACTl0415 7ACTl0415 7ACTl0415 7ACTl0415 7ACTl0415 7ACTl0415
MPg External Grillle for TMT Kit code 7ACVF0330 7ACVF0331 7ACVF0332 7ACVF0333 7ACVF0334 7ACVF0333 7ACVF0334
BacAuxiliary drain pan for AWC/AWN Kit code 7ACTl0394 7ACTl0394 7ACTl0394 7ACTl0394 7ACTl0394 7ACTl0394 7ACTl0394
Auxiliary drain pan for AHC/AHNleft Kit code 7ACTl0446 7ACTl0446 7ACTl0446 7ACTl0446 7ACTl0446 7ACTl0448 -Right Kit code 7ACTl0445 7ACTl0445 7ACTl0445 7ACTl0445 7ACTl0445 7ACTl0447 -
alV Rear panel for glass wall for AWC with feet Kit code 7ACTl0420 7ACTl0421 7ACTl0422 7ACTl0423 7ACTl0424 7ACTl0425 7ACTl0426
tHi Inlet perforated plate with filter for AWC/AHC Kit code 7ACTl0428 7ACTl0429 7ACTl0430 7ACTl0431 7ACTl0432 7ACTl0431 7ACTl0432
crg Discharge duct collar for AWN/AHN Kit code 7ACTl0406 7ACTl0407 7ACTl0408 7ACTl0409 7ACTl0410 7ACTl0409 7ACTl0410
tMtWall telescopic duct without filter for AWN/AWC Kit code 7ACTl0399 7ACTl0400 7ACTl0401 7ACTl0402 7ACTl0403 7ACTl0402 7ACTl0403
External Grillle for TMT Kit code 7ACVF0336 7ACVF0337 7ACVF0338 7ACVF0339 7ACVF0340 7ACVF0339 7ACVF0340
Prc Drain pan pump
AWC/AWN Code kit 7ACFH0603 7ACFH0603 7ACFH0603 7ACFH0603 7ACFH0603 7ACFH0603 7ACFH0603
AHC/AHN Code kit 7ACFH0631 7ACFH0631 7ACFH0631 7ACFH0631 7ACFH0631 7ACFH0632 l=7ACFH0635
R=7ACFH0634tag Antifreeze thermostat Kit code 7ACEl1464 7ACEl1464 7ACEl1464 7ACEl1464 7ACEl1464 7ACEl1464 7ACEl1464
FaExternal filter section for AHN when ducted at suction side Kit code 7ACVF0410 7ACVF0411 7ACVF0412 7ACVF0413 7ACVF0414 7ACVF0413 7ACVF0414
Suspension kit Kit code 7ACTl0486 7ACTl0486 7ACTl0486 7ACTl0486 7ACTl0486 7ACTl0486 7ACTl0486rt Back full air intake with support feet Kit code 7ACVF0342 7ACVF0343 7ACVF0344 7ACVF0345 7ACVF0346 7ACVF0345 7ACVF0346
rP
Back partial air intake without support feet Kit code 7ACVF0348 7ACVF0349 7ACVF0350 7ACVF0351 7ACVF0352 7ACVF0351 7ACVF0352
Floor air intake without support feet for AWN/AHN Kit code 7ACVF0354 7ACVF0355 7ACVF0356 7ACVF0357 7ACVF0358 7ACVF0357 7ACVF0358
rVca-rtAir intake arrangement with moto-rized (non controlled) on/off damper (back or/and front intake)
Right kit code 7ACVF0360 7ACVF0361 7ACVF0362 7ACVF0363 7ACVF0364 7ACVF0363 7ACVF0364
left kit code 7ACVF0366 7ACVF0367 7ACVF0368 7ACVF0369 7ACVF0370 7ACVF0369 7ACVF0370
rVca-rcAir intake arrangement with moto-rized (non controlled) on/off damper (floor or/and front intake)
Right kit code 7ACVF0372 7ACVF0373 7ACVF0374 7ACVF0375 7ACVF0376 7ACVF0375 7ACVF0376
left kit code 7ACVF0378 7ACVF0379 7ACVF0380 7ACVF0381 7ACVF0382 7ACVF0381 7ACVF0382
rVcM-rt Air intake arrangement with manual damper (back or/and front intake)
Right kit code 7ACVF0384 7ACVF0385 7ACVF0386 7ACVF0387 7ACVF0388 7ACVF0387 7ACVF0388left kit code 7ACVF0390 7ACVF0391 7ACVF0392 7ACVF0393 7ACVF0394 7ACVF0393 7ACVF0394
rVcM-rc Air intake arrangement with manual damper (floor or/and front intake)
Right kit code 7ACVF0396 7ACVF0397 7ACVF0398 7ACVF0399 7ACVF0400 7ACVF0399 7ACVF0400left kit code 7ACVF0402 7ACVF0403 7ACVF0404 7ACVF0405 7ACVF0406 7ACVF0405 7ACVF0406
Floor FiX Floor fix for MP and AlV Kit code 7ACTl0459 7ACTl0459 7ACTl0459 7ACTl0459 7ACTl0459 7ACTl0459 7ACTl0459
PlEnuM aPS
Discharge plenum with duct 1 x 200 mm for AWN/AHN Kit code 7ACVF0486 7ACVF0487 - - - - -
Discharge plenum with duct 1 x 250 mm Ob for AWN/AHN Kit code - 7ACVF0488 7ACVF0489 7ACVF0491 - 7ACVF0491 -
Discharge plenum with duct 2 x 200 mm for AWN/AHN Kit code - - 7ACVF0490 7ACVF0492 - 7ACVF0492 -
Discharge plenum with duct 3 x 200 mm for AWN/AHN Kit code - - - - 7ACVF0493 7ACVF0495 7ACVF0493
Discharge plenum with duct 3 x 250 mm Ob for AWN/AHN Kit code - - - - 7ACVF0494 - 7ACVF0494
PlEnuM aPSa
Return & Discharge plenum with duct 1 x 200 mm Kit code 7ACVF0496 7ACVF0497 - - - - -
Return & Discharge plenum with duct 1 x 250 mm Ob Kit code - 7ACVF0498 7ACVF0499 7ACVF0501 - 7ACVF0501 -
Return & Discharge plenum with duct 2 x 200 mm Kit code - - 7ACVF0500 7ACVF0502 - 7ACVF0502 -
Return & Discharge plenum with duct 3 x 200 mm Kit code - - - - 7ACVF0503 7ACVF0505 7ACVF0503
Return & Discharge plenum with duct 3 x 250 mm Ob Kit code - - - - 7ACVF0504 - 7ACVF0504
CONTROL ACCESSORIES (SUPPLIED LOOSE) 20 30 40 50 60 70 80
cMV Fan speed selector for mounting on unit
Right kit code 7ACEl1454 7ACEl1454 7ACEl1454 7ACEl1454 7ACEl1454 7ACEl1454 7ACEl1454left kit code 7ACEl1453 7ACEl1453 7ACEl1453 7ACEl1453 7ACEl1453 7ACEl1453 7ACEl1453
cMVM Fan speed selector for wall mounting Kit code 7ACEl1435 7ACEl1435 7ACEl1435 7ACEl1435 7ACEl1435 7ACEl1435 7ACEl1435
tBVBulb thermostat for mounting on unit - action on control valve and fan
Right kit code 7ACEl1456 7ACEl1456 7ACEl1456 7ACEl1456 7ACEl1456 7ACEl1456 7ACEl1456
left kit code 7ACEl1455 7ACEl1455 7ACEl1455 7ACEl1455 7ACEl1455 7ACEl1455 7ACEl1455
tBMV
Bulb thermostat with summer/winter manual switch for mounting on unit - action on control valve and fan
Right kit code 7ACEl1431 7ACEl1431 7ACEl1431 7ACEl1431 7ACEl1431 7ACEl1431 7ACEl1431
left kit code 7ACEl1430 7ACEl1430 7ACEl1430 7ACEl1430 7ACEl1430 7ACEl1430 7ACEl1430
trM-VPRemote thermostat withsummer/winter manual switch - action on control valve
Kit code 7ACEl1443 7ACEl1443 7ACEl1443 7ACEl1443 7ACEl1443 7ACEl1443 7ACEl1443
trM-FaRemote thermostat withsummer/winter manual switch - action on control valve and fan
Kit code 7ACEl1440 7ACEl1440 7ACEl1440 7ACEl1440 7ACEl1440 7ACEl1440 7ACEl1440
Pco Mechanical sensor for automatique change over Kit code 7ACEl1473 7ACEl1473 7ACEl1473 7ACEl1473 7ACEl1473 7ACEl1473 7ACEl1473
accessories
28 29
aQS Aquasimp controller for wall mounting Kit code 7ACEl1546 7ACEl1546 7ACEl1546 7ACEl1546 7ACEl1546 7ACEl1546 7ACEl1546
aQS oB Aquasimp controller for AWC mounting Kit code 7ACEl1532 7ACEl1532 7ACEl1532 7ACEl1532 7ACEl1532 7ACEl1532 7ACEl1532
WPt aQS Water probe for Aquasimp Kit code 7ACEl1547 7ACEl1547 7ACEl1547 7ACEl1547 7ACEl1547 7ACEl1547 7ACEl1547taE20 Electronic thermostat TAE20 Kit code 7ACEl1451 7ACEl1451 7ACEl1451 7ACEl1451 7ACEl1451 7ACEl1451 7ACEl1451
taE20+SEH Electronic thermostat TAE20 + change over sensor Kit code 7ACEl1452 7ACEl1452 7ACEl1452 7ACEl1452 7ACEl1452 7ACEl1452 7ACEl1452
SEH Change over sensor for TAE 20 Kit code 7ACEl1233 7ACEl1233 7ACEl1233 7ACEl1233 7ACEl1233 7ACEl1233 7ACEl1233EH relay Electrical heater relay for terminal Kit code 7ACEl1465 7ACEl1465 7ACEl1465 7ACEl1465 7ACEl1465 7ACEl1465 7ACEl1465
Kit aQn FCC controller all configurations supplied loose for Aquafan Kit code 7ACEl1432 7ACEl1432 7ACEl1432 7ACEl1432 7ACEl1432 7ACEl1432 7ACEl1432
aQn acc Aquanet accessories - 6 plugs + 4 jumpers + RCl connector Kit code 7ACEl1492 7ACEl1492 7ACEl1492 7ACEl1492 7ACEl1492 7ACEl1492 7ACEl1492
niu µBMS compatible communication board NIU for Aquanet Kit code 7ACEl1462 7ACEl1462 7ACEl1462 7ACEl1462 7ACEl1462 7ACEl1462 7ACEl1462
Eniu Modbus communication board eNIU for Aquanet Kit code 7ACEl1463 7ACEl1463 7ACEl1463 7ACEl1463 7ACEl1463 7ACEl1463 7ACEl1463
mBMS µBMS supervisor Kit code 7ACEl1448 7ACEl1448 7ACEl1448 7ACEl1448 7ACEl1448 7ACEl1448 7ACEl1448rcl RCl remote control (supplied loose) Kit code 7ACEl1445 7ACEl1445 7ACEl1445 7ACEl1445 7ACEl1445 7ACEl1445 7ACEl1445
ir rec Wall IR receiver for Aquanet (Aqua-net not included) Kit code 7ACEl1364 7ACEl1364 7ACEl1364 7ACEl1364 7ACEl1364 7ACEl1364 7ACEl1364
230 V THERMAL TyPE ON/OFF VALVE 20 30 40 50 60 70 80
aWc aWn
2-way type, one valve for one coil - W2G1
left/right code kit 7ACFH0555 7ACFH0555 7ACFH0555 7ACFH0555 7ACFH0555 7ACFH0579 7ACFH0579
2-way type, two valves for two coils - W2G2
left/right code kit 7ACFH0558 7ACFH0558 7ACFH0558 7ACFH0558 7ACFH0558 7ACFH0582 7ACFH0582
4-way type, one valve for one coil - W4G1
left/right code kit 7ACFH0561 7ACFH0561 7ACFH0561 7ACFH0561 7ACFH0561 7ACFH0585 7ACFH0585
4-way type, two valves for two coils - W4G2
left/right code kit 7ACFH0564 7ACFH0564 7ACFH0564 7ACFH0564 7ACFH0564 7ACFH0588 7ACFH0588
aHc aHn
2-way type, one valve for one coil - W2G1
left kit code 7ACFH0556 7ACFH0556 7ACFH0556 7ACFH0556 7ACFH0556 7ACFH0580 7ACFH0580Right kit code 7ACFH0557 7ACFH0557 7ACFH0557 7ACFH0557 7ACFH0557 7ACFH0581 7ACFH0581
2-way type, two valves for two coils - W2G2
left kit code 7ACFH0559 7ACFH0559 7ACFH0559 7ACFH0559 7ACFH0559 7ACFH0583 7ACFH0583Right kit code 7ACFH0560 7ACFH0560 7ACFH0560 7ACFH0560 7ACFH0560 7ACFH0584 7ACFH0584
4-way type, one valve for one coil - W4G1
left kit code 7ACFH0562 7ACFH0562 7ACFH0562 7ACFH0562 7ACFH0562 7ACFH0586 7ACFH0586Right kit code 7ACFH0563 7ACFH0563 7ACFH0563 7ACFH0563 7ACFH0563 7ACFH0587 7ACFH0587
4-way type, two valves for two coils - W4G2
left kit code 7ACFH0565 7ACFH0565 7ACFH0565 7ACFH0565 7ACFH0565 7ACFH0589 7ACFH0589Right kit code 7ACFH0566 7ACFH0566 7ACFH0566 7ACFH0566 7ACFH0566 7ACFH0590 7ACFH0590
ELECTRICAL HEATER (SUPPLIED LOOSE) 20 30 40 50 60 70 80
inserted into coil300w
500w
configuration must to be defined in accordance with mounted fan coil
600w
750w
900w
1000w
1200w
1500w
1800w
2000w
2250w
2400w
3000w
accessories on stockACCESSORy CODE 20 30 40 50 60 70
Kit ValVE 4W/on-oFF/2PVertical AWC/AWN 7ACFH0561B -Horizontal AHC/AHN 7ACFH0562B (left) -
Kit ValVE 4W/on-oFF/4PVertical AWC/AWN 7ACFH0564B -Horizontal AHC/AHN 7ACFH0565B (left) -
Kit FEEt - MPCabinet AWC/AHC 7ACTl0391B -Concealed AWN/AHN 7ACTl0415B -
Kit MPg Cabinet AWC/AHC 7ACVF0330B 7ACVF0331B 7ACVF0332B 7ACVF0333B 7ACVF0334B 7ACVF0333B
auX drain PanVertical AWC/AWN 7ACTl0394BHorizontal AHC/AHN 7ACTl0446B (left) -
Kit trM-Fa 7ACEl1440BKit c/o SEnSor - Pco 7ACEl1473B
Kit aQuanEt 7ACEl1432BKit rcl- aSSy
aWc 7ACEl1468B
Kit rcl 7ACEl1447BKit air SEnSor aQuanEt 7ACEl1461B
Kit WatEr SEnSor 7ACEl1438BKit niu Board 7ACEl1462B
Kit eniu Board 7ACEl1463BKit taE 20 7ACEl1451B
Kit taE 20 + SHE 7ACEl1452BKit aQuaSiMP on-Board 7ACEl1532
Kit aQuaSiMP Wall-mounted 7ACEl1546Kit aQuaSiMP WPt 7ACEl1547B
30
Commercial Air Conditioning |
31
VPNFan coil unit - cooling and HEating
cooling capacity: from 1.8 to 12.6 kW Heating capacity: from 3.5 to 20.0 kW Sizes: 9
VeRSIONS: 2-Pipes 2-Pipes/2-Wires
CONFIGURATIONS: Horizontal concealed
PRODUCT ADVANTAGES Ease of installation. 3-speed centifugal fan motor. airflow rate between 170 and 2380 m³/h. 3-row coil for optimized cooling performances. coil with hydrophilic fins to improve the condensate flow. Extended drain pan.
MAIN OPTIONS Electrical heater. ducted plenum for air intake.
MAIN ACCESSORIES control.
Operating limit fOr Standard unit
Minimum water temperature +5°C
Maximum water temperature +90°C
Maximum operating pressure 16 bars
Minimum indoor air temperature (room/intake/around unit) 5°C/15% RH
Maximum indoor air temperature (room/intake/around unit) 32°C/70% RH
new
30 31
vpn size 200 300 400 500 600 800 1000 1200 1400CAPACITIES
cooling (1)
total cooling capacity W 1823 3206 3626 5154 5400 7530 9000 10800 12600Water flow l/h 334 569 643 915 950 1238 1565 1809 2054
Water pressure drop kPa 2.9 9.1 12.1 22.5 23.2 10.6 18.2 25.3 36.4Heating (2) Heating capacity W 3515 5519 6558 8795 9321 13108 15320 16569 20021
SOUND LEVELS - HIGH SPEED
Sound pressure level - 12 Pa dB(A) 35 36 41 43 45 46 48 48 50Sound pressure level - 30 Pa dB(A) 39 40 43 45 47 48 50 52 53Sound pressure level - 50 Pa dB(A) 40 44 46 47 49 50 52 54 55
FANS (LS/MS/HS)
Motor number 1 1 1 1 1 2 2 2 2Blower number 1 2 2 2 2 3 3 4 4
airflow m³/h 170/255/340 278/401/525 336/525/680 445/668/890 530/780/1020 700/1050/1400 870/1395/1700 1020/1530/2040 1190/1785/2380ELECTRICAL - HIGH SPEED
Power supply V/Ph/Hz 230 / 1 / 50Power consumption - 12 Pa W 30 37 56 76 96 131 152 189 228Power consumption - 30 Pa W 44 59 72 87 108 167 190 212 253Power consumption - 50 Pa W 49 66 84 100 118 174 210 253 300
WATER CONNECTIONS
Water connection inches G3/4"drain connection inches G3/4"
DIMENSIONS
l x W x H mm 665x565x248 845x565x248 915x565x248 1050x565x248 1050x565x248 1505x565x248 1505x565x248 1755x565x248 2055x565x248WEIGHT
unit weight kg 16 19.5 20.5 22.5 22.5 35 35 41 44.5
(1) Air: 27°C DB / 19,5°C WB , Water: 7°C/12°C (2) Air: 21°C, Water in: 60°C, same water flow as in cooling.
PRODUCT CODES
12 Pa 9004531 9004532 9004533 9004534 9004535 9004537 9004538 9004539 900454030 Pa 9004541 9004542 9004543 9004544 9004545 9004547 9004548 9004549 900455050 Pa 9004551 9004552 9004553 9004554 9004555 9004557 9004558 9004559 9004560
OPTIONS
Electrical Heater
ACCESSORy CODE
trM-VP Remote thermostat withsummer/winter manual switch - action on control valve Kit code 7ACEl1443trM-Fa Remote thermostat withsummer/winter manual switch - action on control valve and fan Kit code 7ACEl1440
Pco Mechanical sensor for automatique change over Kit code 7ACEl1473aQS Aquasimp controller for wall mounting Kit code 7ACEl1546
aQS oB Aquasimp controller for AWC mounting Kit code 7ACEl1532WPt aQS Water probe for Aquasimp Kit code 7ACEl1547
taE20 Electronic thermostat TAE20 Kit code 7ACEl1451taE20+SEH Electronic thermostat TAE20 + change over sensor Kit code 7ACEl1452
SEH Change over sensor for TAE 20 Kit code 7ACEl1233aQn FCC controller all configurations supplied loose for Aquafan Kit code 7ACEl1432
aQn acc Aquanet accessories - 6 plugs + 4 jumpers + RCl connector Kit code 7ACEl1492niu µBMS compatible communication board NIU for Aquanet Kit code 7ACEl1462
Eniu Modbus communication board eNIU for Aquanet Kit code 7ACEl1463mBMS µBMS supervisor Kit code 7ACEl1448
rcl RCl remote control (supplied loose) Kit code 7ACEl1445ir rec Wall IR receiver for Aquanet (Aquanet not included) Kit code 7ACEl1364
32
Commercial Air Conditioning |
33
KOG LN STD4-Way cHillEd WatEr caSSEttE - cooling and HEating
cooling capacity: from 2.3 to 10.2 kW Heating capacity: from 2.2 to 11.6 kW Sizes: 5
VeRSIONS: 2-Pipes 2-Pipes/2-Wires 4-pipes
CONFIGURATIONS: cassette
PRODUCT ADVANTAGES designed for suspended ceiling integration. 600x600 (9, 12 and 18 models) and 600x1200 formats (30 and 45 models). low built-in height: 287 mm. direct access to electrical connection on sliding chassis. integrated valve and electrical connections. 3-speed ac fan motor. Very low operating acoustical levels with new low noise ln versions (9, 12 and 18 models). coil with hydrophilic fins to improve the condensate flow. Fresh air intake. air distribution in adjacent room. integrated condensate drain lift pump up to 600 mm (3-top for 9, 12 and 18 models). infra-red remote control version with valve and change-over. galvanized steel sheet with thermal and acoustical insulation, avoiding condensation on the casing and providing good sound attenuation. Possibility to close one or two discharge flaps. cleanable synthetic-type air filter.
MAIN OPTIONS Electrical heater with inserted heating rod. 2-stage heater available with aqu@net control. ac motor. Selection of 3 speed. large choice of control: aqu@net control or wall-mounted thermostat. 2-way or 3-way on/oFF valve. g1 filter. condensate drain pump. relay. Fuse holder. ModBus communication interface board. design metallic panel with 192 colours and coanda air diffusion (9-12-18 models).
MAIN ACCESSORIES Valve. aqu@net control. Solid ceiling frame. condensate drain pump. auxiliary condensate drain pan. Master and slaves control, up to 4 units max.
SElECTION SOFTWARE Select’it.
Operating limit fOr Standard unit
Minimum water temperature +5°C
Maximum water temperature +70°C (size 09-12-18) +60°C (size 30/45)
Maximum operating pressure 15 bars
Minimum indoor air temperature (room/intake/around unit) 13°C/15% RH
Maximum indoor air temperature (room/intake/around unit) 32°C/70% RH
new
32 33
Kog size 09 ln 12 ln 18 ln 30 45CAPACITIES - 2-PIPE NOMINAL
cooling (1)
total cooling capacity W 2300 3500 4600 6440 10190
Sensible capacity W 1800 3000 3850 4830 7750
Water flow l/h 400 600 790 1208 1753
Water pressure drop kPa 12 18 16 17 23,5
Heating (2) Heating capacity W 3100 4500 5700 8050 11600
CAPACITIES - 4-PIPE NOMINAL
cooling (1)
total cooling capacity W 2300 3500 4600 - 10100
Sensible capacity W 1800 3000 3850 - 7254
Water flow l/h 400 600 790 - 1737
Water pressure drop kPa 12 18 16 - 27
Heating (3)
Heating capacity W 2200 3335 4470 - 6670
Water flow l/h 210 287 380 - 758
Water pressure drop kPa 5 13 28 - 27
SOUND LEVELS (LS/MS/HS)
Sound power level dB(A) 34/40/50 34/40/50 35/41/49/57 47/50/57 47/53/59
Sound pressure level (4) dB(A) 26/32/42 26/32/42 27/33/41/49 39/42/49 39/45/51
nr (4) dB(A) 20/27/37 20/27/37 23/28/35/43 34/37/44 34/40/45
FANS (LS/MS/HS)
number 1 1 1 2 2
airflow m³/h 330/450/720 330/450/720 290/410/580/830 1100/1350/1550 1000/1250/1630
ELECTRICAL (LS/MS/HS)
Power supply V/Ph/Hz 230/1/50
Fan consumption - Std W 20/30/50 20/30/50 21/30/46/71 165/180/200 151/170/180
Electrical heater W 1500 1800 2400 4300 5400
WATER CONNECTIONS
type Gas male threaded
cooling coil inches 1/2" 1/2" 3/4" 1" 1"
Heating coil inches 1/2" 1/2" 1/2" NA 1/2"
DIMENSIONS
casing (lxWxH) mm 571x571x287 1171x571x287
grille (lxWxH) mm 625x625x40 1225x625x40
WEIGHT
unit weight kg 26 28 29 49 55
(1) According to eurovent standard: Air: 27°C DB/19°C WB, Water in: 7°C/12°C.(2) According to eurovent standard: Air: 20°C, Water in: 50°C, same water flow as in cooling.(3) Air: 20°C, Water in: 60°C/50°C.(4) Sound pressure considering a local of 100 m³, a reverberation time of 0,5 sec and a distance of 1 m.
list of options is available page 36. list of accessories is available page 37.
NEW: ON STOCK! configuration: 2 or 4-pipes, terminal block or ir, with or without 3-way valve, no brand.
PRODUCT CODES 09 LN 12 LN 18 LN
2Pipe without valve
K 9 OG 2T SV K 12 OG 2T SV K 18 OG 2T SVCode 7OG052044 7OG052048 7OG052052
2Pipe with 3-w valve
K 9 OG 2T AV K 12 OG 2T AV K 18 OG 2T AVCode 7OG052045 7OG052049 7OG052053
2Pipe ir with 3-w valve
K 9 OG 2T IR AV K 12 OG 2T IR AV K 18 OG 2T IR AVCode 7OG102028 7OG102029 7OG102030
4Pipe without valve
K 9 OG 4T SV K 12 OG 4T SV K 18 OG 4T SVCode 7OG052046 7OG052050 7OG052054
4Pipe with 3-w valve
K 9 OG 4T AV K 12 OG 4T AV K 18 OG 4T AVCode 7OG052047 7OG052051 7OG052055
34
Commercial Air Conditioning |
35
KOG LN EC4-Way cHillEd WatEr caSSEttE - cooling and HEating
cooling capacity: from 2.3 to 4.6 kW Heating capacity: from 2.2 to 5.7 kW Sizes: 3
VeRSIONS: 2-Pipes 2-Pipes/2-Wires 4-pipes
CONFIGURATIONS: cassette
PRODUCT ADVANTAGES designed for suspended ceiling integration 600x600 mm. low built-in height: 287 mm. direct access to electrical connection on sliding chassis. integrated valve and electrical connections. low consumption Ec fan motor. Very low operating acoustical levels with new low noise ln versions. coil with hydrophilic fins to improve the condensate flow. Fresh air intake. air distribution in adjacent room. integrated 3-top condensate drain lift pump up to 600 mm. infra-red remote control version with valve and change-over. galvanized steel sheet with thermal and acoustical insulation, avoiding condensation on the casing and providing good sound attenuation. Possibility to close one or two discharge flaps. cleanable synthetic-type air filter.
MAIN OPTIONS Electrical heater with inserted heating rod. 2-stage heater available with aqu@net control. Ec motor. Selection of 3 speed with EcoSpeed3 board. large choice of control: aqu@net control or wall-mounted thermostat. 2-way or 3-way on/oFF valve. g1 filter. condensate drain pump. relay. Fuse holder. ModBus communication interface board. design metallic panel with 192 colours and coanda air diffusion (9-12-18 models).
MAIN ACCESSORIES Valve. aqu@net control. Solid ceiling frame. condensate drain pump. auxiliary condensate drain pan.
SElECTION SOFTWARE Select’it.
Operating limit fOr Standard unit
Minimum water temperature +5°C
Maximum water temperature +70°C (size 09-12-18) +60°C (size 30/45)
Maximum operating pressure 15 bars
Minimum indoor air temperature (room/intake/around unit) 13°C/15% RH
Maximum indoor air temperature (room/intake/around unit) 32°C/70% RH
new
34 35
Kog size 09 ln 12 ln 18 lnCAPACITIES - 2-PIPE NOMINAL
cooling (1)
total cooling capacity W 2300 3500 4600
Sensible capacity W 1800 3000 3850
Water flow l/h 400 600 790
Water pressure drop kPa 12 18 16
Heating (2) Heating capacity W 3100 4500 5700
CAPACITIES - 4-PIPE NOMINAL
cooling (1)
total cooling capacity W 2300 3500 4600
Sensible capacity W 1800 3000 3850
Water flow l/h 400 600 790
Water pressure drop kPa 12 18 16
Heating (3)
Heating capacity W 2200 3335 4470
Water flow l/h 210 287 380
Water pressure drop kPa 5 13 28
SOUND LEVELS (LS/MS/HS)
Sound power level dB(A) 34/40/50 34/40/50 35/41/49/57
Sound pressure level (4) dB(A) 26/32/42 26/32/42 27/33/41/49
nr (4) dB(A) 20/27/37 20/27/37 23/28/35/43
FANS (LS/MS/HS)
number 1 1 1
airflow m³/h 330/450/720 330/450/720 290/410/580/830
ELECTRICAL (LS/MS/HS)
Power supply V/Ph/Hz 230/1/50
Fan consumption - Ec W 08/11/26 08/11/26 8/9/23/41
Electrical heater W 1500 1800 2400
WATER CONNECTIONS
type Gas male threaded
cooling coil inches 1/2" 1/2" 3/4"
Heating coil inches 1/2" 1/2" 1/2"
DIMENSIONS
casing (lxWxH) mm 571x571x287
grille (lxWxH) mm 625x625x40
WEIGHT
unit weight kg 26 28 29
(1) According to eurovent standard: Air: 27°C DB/19°C WB, Water in: 7°C/12°C.(2) According to eurovent standard: Air: 20°C, Water in: 50°C, same water flow as in cooling.(3) Air: 20°C, Water in: 60°C/50°C.(4) Sound pressure considering a local of 100m³, a reverberation time of 0,5 sec and a distance of 1 m.
list of options is available page 36. list of accessories is available page 37.
36
Commercial Air Conditioning |
37
OPTIONS
230 V Thermal Type ON/OFF
W2g1 2-way type, one valve for one coil - W2G1
W2g2 2-way type, two valves for two coils - W2G2
W4g1 4-way type, one valve for one coil - W4G1
W4g2 4-way type, two valves for two coils - W4G2
Fuse holder 2P-4P
Fuse holder 2P2W
Prc Drain pump
REGULATION
Eco 3 EcoSpeed Card for EC motor
Pco Mechanical sensor for automatique change over
aQuanEt Aquanet controller
niu µBMS compatible communication board NIU for Aquanet
Eniu Modbus communication board eNIU for Aquanet
options
36 37
ACCESSORy CODE 09 LN 12 LN 18 LN 30 45
trM-VPRemote thermostat withsummer/winter manual switch - action on control valve
Code 7ACEl1443
trM-FaRemote thermostat withsummer/winter manual switch - action on control valve and fan
Code 7ACEl1440
aQuanEt Aquanet control Code 7ACEl1432
rcl RCl remote control (supplied loose) Code 7ACEl1445
niu µBMS compatible communica-tion board NIU for Aquanet Code 7ACEl1462
eniu Modbus communication board eNIU for Aquanet Code 7ACEl1463
µBMS µBMS supervisor Code 7ACEl1448
aQuaSiMP Aquasimp controller for wall mounting Code 7ACEl1546
WPt for aQuaSiMP Water probe for Aquasimp Code 7ACEl1547
taE20 Electronic thermostat TAE20 Code 7ACEl1451
taE20+SEH Electronic thermostat TAE20 + change over sensor Code 7ACEl1452
SEH Change over sensor for TAE 20 Code 7ACEl1233
relay kit M/S relay kit Code 7ACEl1207
3-w valve + condensate tray - 2P 3-w valve + condensate tray - 2P Code - - - 7ACFH0051 7ACFH0052
3-w valve + condensate tray - 4P 3-w valve + condensate tray - 2P Code - - - 7ACFH0122
drain Pan - 2P Aux drain pan Code 7ACTl0083 7ACTl0005 7ACTl0005
drain pan - 4P Aux drain pan Code 7ACTl0083 - 7ACTl0040
Special frame for solid ceiling Special frame for solid ceiling Code 7ACVF0091A - -
accessories
38
Commercial Air Conditioning |
39
KCO LN STD1-Way cHillEd WatEr caSSEttE - cooling and HEating
cooling capacity: from 1.7 to 4.3 kW Heating capacity: from 2.3 to 6.4 kW Sizes: 3
VeRSIONS: 2-Pipes 2-Pipes/2-Wires 4-pipes
CONFIGURATIONS: cassette
PRODUCT ADVANTAGES innovative technical solution for architectural installations. advance aesthetic and harmonious design. designed for suspended ceiling integration. Fit for 600 mm frame width. optimum coanda effect through uniform airflow. adjustable multidirectionnal Play® diffusers. High induction diffusion grille. 6-speed ac fan motor. Very low operating acoustical levels. galvanized steel sheet with special acoustical insulation, avoiding condensation on the casing and providing good sound attenuation. coil with hydrophilic fins to improve the condensate flow. cleanable synthetic fiber g3-class air filter.
MAIN OPTIONS Electrical heater with inserted heating rod. 2-stage heater available with aqu@net control. Selection of 3 speed. large choice of control: aqu@net control or wall-mounted thermostat. 2-way or 3-way on/oFF valve. g3 filter. 3-top condensate drain pump. condensate gravity plenum. Fresh air intake. Fuse holder. ModBus communication interface board.
MAIN ACCESSORIES aqu@net control room thermostat.
SElECTION SOFTWARE Eole Kco.
Operating limit fOr Standard unit
Minimum water temperature +5°C
Maximum water temperature +90°C
Maximum operating pressure 10 bars
Minimum indoor air temperature (room/intake/around unit) 5°C/15% RH
Maximum indoor air temperature (room/intake/around unit) 32°C/70% RH
38 39
Kco size 60 90 120CAPACITIES - 2-PIPE NOMINAL
cooling (1)
total cooling capacity W 1740 3385 4340Sensible capacity W 1392 2493 3340
Water flow l/h 300 580 750Water pressure drop kPa 41 20 111
Heating (2) Heating capacity W 2277 4232 5511CAPACITIES - 4-PIPE NOMINAL
cooling (1)
total cooling capacity W 1740 3385 4340Sensible capacity W 1392 2493 3340
Water flow l/h 300 580 750Water pressure drop kPa 57 20 33
Heating (3)
Heating capacity W 2950 4898 6354Water flow l/h 250 420 550
Water pressure drop kPa 25 79 77SOUND LEVELS (LS/MS/HS)
Sound power level dB(A) 31/41/55 37/47/58 33/43/58Sound pressure level (4) dB(A) 23/33/47 29/39/50 25/35/50
nr (4) dB(A) 18/28/42 24/34/45 20/30/45FANS (LS/MS/HS)
number 1 1 2airflow m³/h 117/177/357 210/338/550 192/340/700
ELECTRICAL (LS/MS/HS)
Power supply V/Ph/Hz 230/1/50Fan consumption - Std W 15/26/54 29/50/108 29/50/105
Electrical heater W 1200 2000 2500WATER CONNECTIONS
type Gas female threadedcooling coil inches 1/2" 1/2" 1/2"Heating coil inches 1/2" 1/2" 1/2"
DIMENSIONS
casing (lxWxH) mm 595x600x 300 895x600x300 1195x600x300WEIGHT
unit weight kg 23 33 48
(1) According to eurovent standard: Air: 27°C DB/19°C WB, Water in: 7°C/12°C.(2) According to eurovent standard: Air: 20°C, Water in: 50°C, same water flow as in cooling.(3) According to eurovent standard: Air: 20°C, Water in: 70°C/60°C.(4) Sound pressure considering a local of 100 m³, a reverberation time of 0,5 sec and a distance of 1 m.
list of options is available page 42. list of accessories is available page 43.
40
Commercial Air Conditioning |
41
KCO LN EC1-Way cHillEd WatEr caSSEttE - cooling and HEating
cooling capacity: from 1.7 to 4.3 kW Heating capacity: from 2.3 to 6.4 kW Sizes: 3
VeRSIONS: 2-Pipes 2-Pipes/2-Wires 4-pipes
CONFIGURATIONS: cassette
PRODUCT ADVANTAGES innovative technical solution for architectural installations. advance aesthetic and harmonious design. designed for suspended ceiling integration. Fit for 600 mm frame width. optimum coanda effect through uniform airflow. adjustable multidirectionnal Play® diffusers. High induction diffusion grille. low consumption Ec fan motor. Very low operating acoustical levels. galvanized steel sheet with special acoustical insulation, avoiding condensation on the casing and providing good sound attenuation. coil with hydrophilic fins to improve the condensate flow. cleanable synthetic fiber g3-class air filter.
MAIN OPTIONS Electrical heater with inserted heating rod. 2-stage heater available with aqu@net control. Ec fan motor. Selection of 3 speed with EcoSpeed3 board. large choice of control: aqu@net control or wall-mounted thermostat. 2-way or 3-way on/oFF valve. g3 filter. 3-top condensate drain pump. condensate gravity plenum. Fresh air intake. Fuse holder. ModBus communication interface board.
MAIN ACCESSORIES aqu@net control. room thermostat.
SElECTION SOFTWARE Eole Kco.
Operating limit fOr Standard unit
Minimum water temperature +5°C
Maximum water temperature +90°C
Maximum operating pressure 10 bars
Minimum indoor air temperature (room/intake/around unit) 5°C/15% RH
Maximum indoor air temperature (room/intake/around unit) 32°C/70% RH
new
40 41
Kco size 60 90 120CAPACITIES - 2-PIPE NOMINAL
cooling (1)
total cooling capacity W 1740 3385 4340Sensible capacity W 1392 2493 3340
Water flow l/h 300 580 750Water pressure drop kPa 41 20 111
Heating (2) Heating capacity W 2277 4232 5511CAPACITIES - 4-PIPE NOMINAL
cooling (1)
total cooling capacity W 1740 3385 4340Sensible capacity W 1392 2493 3340
Water flow l/h 300 580 750Water pressure drop kPa 57 20 33
Heating (3)
Heating capacity W 2950 4898 6354Water flow l/h 250 420 550
Water pressure drop kPa 25 79 77SOUND LEVELS (LS/MS/HS)
Sound power level dB(A) 31/41/55 37/47/58 33/43/58Sound pressure level (4) dB(A) 23/33/47 29/39/50 25/35/50
nr (4) dB(A) 18/28/42 24/34/45 20/30/45FANS (LS/MS/HS)
number 1 1 2airflow m³/h 117/177/357 210/338/550 192/340/700
ELECTRICAL (LS/MS/HS)
Power supply V/Ph/Hz 230/1/50Fan consumption - Ec W 4/9/45 16/29/69 9/20/67
Electrical heater W 1200 2000 2500WATER CONNECTIONS
type Gas female threadedcooling coil inches 1/2" 1/2" 1/2"Heating coil inches 1/2" 1/2" 1/2"
DIMENSIONS
casing (lxWxH) mm 595x600x 300 895x600x300 1195x600x300WEIGHT
unit weight kg 23 33 48
(1) According to eurovent standard: Air: 27°C DB/19°C WB, Water in: 7°C/12°C.(2) According to eurovent standard: Air: 20°C, Water in: 50°C, same water flow as in cooling.(3) According to eurovent standard: Air: 20°C, Water in: 70°C/60°C.(4) Sound pressure considering a local of 100 m³, a reverberation time of 0,5 sec and a distance of 1 m.
list of options is available page 42. list of accessories is available page 43.
42
Commercial Air Conditioning |
43
OPTIONS
ValVE 230 V Thermal Type ON/OFF
W2g1 2-way type, one valve for one coil - W2G1
W2g2 2-way type, two valves for two coils - W2G2
W4g1 4-way type, one valve for one coil - W4G1
W4g2 4-way type, two valves for two coils - W4G2
ELECTRICAL HEATER KCO 60 KCO 90 KCO 120
BE1 400W 1000W 1500W
BE2 800W 2000W 2500W
BE3 1200W
AIR SIDE
Fresh air intake diam. 100mm
Fresh air intake diam. 125mm
Condensat gravity plenum
REGULATION
Eco 3 Ecospeed card for EC MOTOR
Pco Mechanical sensor for automatique change over
aQuanEt Aquanet controller
niu µBMS compatible communication board NIU for Aquanet
Eniu Modbus communication board eNIU for Aquanet
2 Pipes and 4 Pipes Fuse Holder
2P2W Fuse Holder
Prc Drain pump
options
42 43
ACCESSORIES KCO 60 KCO 90 KCO 120
trM-VP Remote thermostat withsummer/winter manual switch - action on control valve 7ACEl1443
trM-Fa Remote thermostat withsummer/winter manual switch - action on control valve and fan 7ACEl1440
taE20 Electronic thermostat TAE20 7ACEl1451
taE20+SEH Electronic thermostat TAE20 + change over sensor 7ACEl1452
SEH Change over sensor for TAE 20 7ACEl1233
aQS Aquasimp controller for wall mounting 7ACEl1546
WPt aQS Water probe for Aquasimp 7ACEl1547
niu µBMS compatible communication board NIU for Aquanet 7ACEl1462
Eniu Modbus communication board eNIU for Aquanet 7ACEl1463
rcl RCl remote control (supplied loose) 7ACEl1445
mBMS µBMS supervisor 7ACEl1448
Suspension kit 7ACTl0486
accessories
44
Commercial Air Conditioning |
45
H@WairHigH-Wall cHillEd WatEr unit - cooling and HEating
cooling capacity: from 2.2 to 4.7 kW Heating capacity: from 2.9 to 5.9 kW Sizes: 4
VeRSIONS: 2-Pipes
CONFIGURATIONS: High-wall
PRODUCT ADVANTAGES aesthetic design suitable for home and hotel applications. Silent unit for optimum customer comfort. Version with integrated 3-way valve and ir control. choice between ir or wall-mounted thermostat. coil with hydrophilic fins to improve the condensate flow. light unit for easy installation. Very easy servicing through removable front plate. cleanable synthetic-type air filter. indoor unit compatible with all airwell chilled water production units.
MAIN OPTIONS rc-08a ir control. terminal block for wall-mounted thermostat. Version with 3-way on/oFF valve. 3-speed tangential fan motor. Motorized flap. Electro-static anti-bacteria filter. Pipe connectors. drilling template.
MAIN ACCESSORIES Valve. aqu@net control. Wall-mounted thermostat.
Operating limit fOr Standard unit
Minimum water temperature +5°C
Maximum water temperature +60°C
Maximum operating pressure 15 bars
Minimum indoor air temperature (room/intake/around unit) 6°C/15% RH
Maximum indoor air temperature (room/intake/around unit) 32°C/70% RH
new
44 45
h@wair size haw007 haw009 hwa012 haw022CAPACITIES NOMINAL
cooling (1)
Total cooling capacity W 2200 2900 3600 4700Sensible capacity W 1870 2400 3000 3700Water flow l/h 400 500 620 810Water pressure drop kPa 10 16 35 50
Heating (2) Heating capacity W 2900 3700 4800 5850SOUND LEVELS (LS/MS/HS)
Sound power level dB(A) 36/40/44 38/42/48 45/48/52 50/54/58Sound pressure level (3) dB(A) 24/32/36 30/34/40 37/40/44 42/46/50NR (3) dB(A) 19/27/31 25/29/35 32/35/39/ 37/41/45
FANS (LS/MS/HS)
Number 1 1 1 1Airflow m³/h 320/380/450 400/500/600 550/650/750 650/750/900
ELECTRICAL (LS/MS/HS)
Power supply V/Ph/Hz 230/1/50 Fan consumption W 22/26/28 22/26/28 25/28/31 43/47/58
WATER CONNECTIONS
Type Gas female threadedCoil inches 1/2" 1/2" 1/2" 1/2"
DIMENSIONS
Casing (lxWxH) mm 845x275x180 940x298x200WEIGHT
Unit weight kg 11 11 13 13
(1) According to eurovent standard: Air: 27°C DB/19°C WB, Water in: 7°C/12°C.(2) According to eurovent standard: Air: 20°C, Water in: 50°C, same water flow as in cooling.(3) Sound pressure considering a local of 100m³, a reverberation time of 0,5 sec and a distance of 1 m.
PRODUCT CODES
2Pipe ir Without valve H@Wair 7 IR SV H@Wair 9 IR SV H@Wair 18 IR SV H@Wair 22 IR SVcode AWFC-HAW007-A AWFC-HAW009-A AWFC-HAW018-A AWFC-HAW022-A
2Pipe ir With valve - H@Wair 9 IR AV - H@Wair 22 IR AVcode AWFC-HAW009-B AWFC-HAW022-B
2Pipe Without valve H@Wair 7 TB SV H@Wair 9 TB SV H@Wair 18 TB SV H@Wair 22 TB SVcode AWFC-HAW007-C AWFC-HAW009-C AWFC-HAW018-C AWFC-HAW022-C
ACCESSORy CODE
trM-VPRemote thermostat withsummer/winter manual switch - action on control valve
Code 7ACEl1443
trM-FaRemote thermostat withsummer/winter manual switch - action on control valve and fan
Code 7ACEl1440
Pco Mechanical sensor for automatique change over Code 7ACEl1473
aQuanEt Aquanet control - remote Code 7ACEl1432
rcl RCl remote control (supplied loose) Code 7ACEl1445
niu µBMS compatible communication board NIU for Aquanet Code 7ACEl1462
eniu Modbus communication board eNIU for Aquanet Code 7ACEl1463
µBMS µBMS supervisor Code 7ACEl1448
aQuaSiMP Aquasimp controller for wall mounting Code 7ACEl1546
WPt for aQuaSiMP Water probe for Aquasimp Code 7ACEl1547taE20 Electronic thermostat TAE20 Code 7ACEl1451
taE20+SEH Electronic thermostat TAE20 + change over sensor Code 7ACEl1452
SEH Change over sensor for TAE 20 Code 7ACEl1233
46
Commercial Air Conditioning |
47
VH STDHigH Static PrESSurE ductaBlE Fan coil unit - cooling and HEating
cooling capacity: from 2.1 to 28.4 kW Heating capacity: from 3.5 to 33.9 kW Sizes: 9
VeRSIONS: 2-Pipes 2-Pipes/2-Wires 4-pipes
CONFIGURATIONS: ceiling concealed
PRODUCT ADVANTAGES Ease of installation and maintenance. High static pressure avaiable up to 200 Pa. airflow rate up to 4650 m³/h. Multi-speed ac fan motor. Very low operating acoustical levels in low speeds. Selection of hydraulic and electric service side. configuration flexibility thanks to modular conception. Various air intake configuration: rectangular or duct connections. coil with hydrophilic fins to improve the condensate flow. g3 filter as standard. compliant with ErP directive.
MAIN OPTIONS Electrical heater with inserted heating rod. 2-stage heater available with aqu@net control. Selection of 3 speed. large choice of control: Electro-mechanic, electronic, on-board or wall-mounted. ModBus communication interface board. 2-way or 3-way on/oFF valve. g4 filter in option. ducted or rectangular plenum for air intake or dischage. Fresh air intake. double skin insulation for ErP applications. auxiliary condensate drain pan. condensate drain pump. relay. Fuse holder. individual packaging.
MAIN ACCESSORIES Valve. control. ir control. drain pan. condensate drain pump. choice of ducted plenum for air intake or dischage.
SElECTION SOFTWARE Select’ it.
Operating limit fOr Standard unit
Minimum water temperature +5°C
Maximum water temperature +90°C
Maximum operating pressure 10 bars
Minimum indoor air temperature (room/intake/around unit) 5°C/15% RH
Maximum indoor air temperature (room/intake/around unit) 32°C/70% RH
46 47
vh size 03 05 07 10 15 18 21 24 27CAPACITIES - 2-PIPE - NOMINAL AT 50 PA
cooling (1)
Total cooling capacity W 2083 2898 6165 8458 14819 18888 21947 23866 28364
Sensible capacity W 1909 2351 4873 6408 12896 14923 16413 18623 20761
Water flow l/h 360 500 1060 1450 2550 3250 3800 4100 4900
Water pressure drop kPa 10 9 45 33 29 31 45 27 35
Heating (2) Heating capacity W 3480 4564 8360 11658 19913 23535 25319 32282 33870
CAPACITIES - 4-PIPE - NOMINAL AT 50 PA
cooling (1)
Total cooling capacity W 1649 2954 5607 6409 12575 14251 19532 21067 23945
Sensible capacity W 1595 2539 4358 5294 11666 12814 15153 17346 18686
Water flow l/h 285 510 965 1100 2170 2450 3360 3630 4130
Water pressure drop kPa 6 9 33 16 18 23 52 31 30
Heating (3)
Heating capacity W 3770 5984 8815 13418 25215 25213 25213 32766 32786
Water flow l/h 320 520 760 1150 2170 2170 2170 2820 2820
Water pressure drop kPa 12 50 17 50 160 98 98 122 95
SOUND LEVELS (LS/MS/HS)
Sound power level (4) dB(A) 41/56/69 48/53/58 54/60/63 51/59/64 52/65/72 52/65/72 52/65/72 35/69/75 35/69/75
Sound pressure level (5) dB(A) 20/35/48 27/32/37 33/39/42 30/38/43 31/44/51 31/44/51 31/44/51 44/48/54 44/48/54
NR (5) dB(A) 15/31/44 21/27/32 27/34/37 25/33/38 27/40/47 27/40/47 27/40/47 40/44/51 40/44/51
FANS (LS/MS/HS)
Number 1 2 2 2 2 2 2 2 2
Airflow at 50 Pa m³/h -/271/570 -/340/620 648/977/1251 643/1027/1486 671/2112/3176 671/2112/3176 671/2112/3176 1938/2413/3882 1938/2413/3882
ELECTRICAL (LS/MS/HS)
Power supply V/Ph/Hz 230/1/50-60
Fan consumption - STD W 42/104/207 53/69/120 132/182/222 136/195/250 180/421/675 180/421/675 180/421/675 420/530/870 420/530/870
Electrical heater (max) W 1600 2000 2000 2000 3000 3000 3000 3000 3000
WATER CONNECTIONS
Type Gas female threaded Gas male threaded
Cooling coil 2-pipe inches 1/2" 1/2" 1/2" 1/2" 1" 1 1/4" 1 1/4" 1 1/4" 1 1/4"
Cooling coil 4-pipe inches 1/2" 1/2" 1/2" 1/2" 1" 1" 1" 1 1/4" 1 1/4"
Heating coil inches 1/2" 1/2" 1/2" 1/2" 3/4" 3/4" 3/4" 3/4" 3/4"
DIMENSIONS
rect-rect lxWxH mm 600x600x200 698x1060x230 698x1200x250 698x1200x300 798x1380x375 798x1380x375 798x1380x375 798x1500x450 798x1500x450
circ-circ lxWxH mm 890x600x200 1014x1060x230 1014x1200x250 1014x1200x250 - - - - -
WEIGHT
rect-rect Unit weight kg 19 35 42 48 63 65 67 76 80
circ-circ Unit weight kg 22 41 48 55 - - - - -
(1) Air: 27°C DB/19°C WB, Water in: 7°C/12°C, 50 Pa external static pressure.(2) Air: 20°C, Water in: 50°C, same water flow as in cooling, 50 Pa external static pressure.(3) Air: 20°C, Water in: 70°C/60°C, 50 Pa external static pressure.(4) According eurovent standard: Return + radiated sound power level given for a unit with 50 Pa external static pressure in medium speed.(5) Sound pressure considering an hypothetical installation and local attenuation of 21 dB.
list of options is available page 50. list of accessories is available page 51.
48
Commercial Air Conditioning |
49
VH ECHigH Static PrESSurE ductaBlE Fan coil unit - cooling and HEating
cooling capacity: from 2.1 to 8.5 kW Heating capacity: from 3.5 to 13.4 kW Sizes: 4
VeRSIONS: 2-Pipes 2-Pipes/2-Wires 4-pipes
CONFIGURATIONS: ceiling concealed
PRODUCT ADVANTAGES Ease of installation and maintenance. High static pressure avaiable up to 200 Pa. airflow rate up to 4650 m³/h. Energy saving Ec fan motor. Very low operating acoustical levels in low speeds. Selection of hydraulic and electric service side. configuration flexibility thanks to modular conception. Various air intake configuration: rectangular or duct connections. coil with hydrophilic fins to improve the condensate flow. g3 filter as standard. compliant with ErP directive.
MAIN OPTIONS Electrical heater with inserted heating rod. 2-stage heater available with aqu@net control. Selection of 3 speed. Ec motor. large choice of control: Electro-mechanic, electronic, on-board or wall-mounted. ModBus communication interface board. 2-way or 3-way on/oFF valve. g4 filter in option. ducted or rectangular plenum for air intake or dischage. Fresh air intake. double skin insulation for ErP applications. auxiliary condensate drain pan. condensate drain pump. relay. Fuse holder. individual packaging.
MAIN ACCESSORIES Valve. control. ir control. drain pan. condensate drain pump. choice of ducted plenum for air intake or dischage.
SElECTION SOFTWARE Select’ it.
Operating limit fOr Standard unit
Minimum water temperature +5°C
Maximum water temperature +90°C
Maximum operating pressure 10 bars
Minimum indoor air temperature (room/intake/around unit) 5°C/15% RH
Maximum indoor air temperature (room/intake/around unit) 32°C/70% RH
48 49
vh size 03 05 07 10CAPACITIES - 2-PIPE NOMINAL AT 50 PA
cooling (1)
Total cooling capacity W 2083 2898 6165 8458Sensible capacity W 1909 2351 4873 6408Water flow l/h 360 500 1060 1450Water pressure drop kPa 10 9 45 33
Heating (2) Heating capacity W 3480 4564 8360 11658CAPACITIES - 4-PIPE NOMINAL AT 50 PA
cooling (1)
Total cooling capacity W 1649 2954 5607 6409Sensible capacity W 1595 2539 4358 5294Water flow l/h 285 510 965 1100Water pressure drop kPa 6 9 33 16
Heating (3)
Heating capacity W 3770 5984 8815 13418Water flow l/h 320 520 760 1150Water pressure drop kPa 12 50 17 50
SOUND LEVELS (LS/MS/HS)Sound power level (4) dB(A) 41/56/69 48/53/58 54/60/63 51/59/64Sound pressure level (5) dB(A) 20/35/48 27/32/37 33/39/42 30/38/43NR (5) dB(A) 15/31/44 21/27/32 27/34/37 25/33/38
FANS (LS/MS/HS)Number 1 2 2 2Airflow at 50 Pa m³/h -/271/570 -/340/620 648/977/1251 643/1027/1486
ELECTRICAL (LS/MS/HS)Power supply V/Ph/Hz 230/1/50-60Fan consumption - EC W 5/17/89 5/15/111 13/58/209 16/59/229Electrical heater (max) W 1600 2000 2000 2000
WATER CONNECTIONS Type Gas female threadedCooling coil 2-pipe inches 1/2" 1/2" 1/2" 1/2"Cooling coil 4-pipe inches 1/2" 1/2" 1/2" 1/2"Heating coil inches 1/2" 1/2" 1/2" 1/2"
DIMENSIONS
rect-rect lxWxH mm 600x600x200 698x1060x230 698x1200x250 698x1200x300circ-circ lxWxH mm 890x600x200 1014x1060x230 1014x1200x250 1014x1200x250
WEIGHT
rect-rect Unit weight kg 19 35 42 48circ-circ Unit weight kg 22 41 48 55
(1) Air: 27°C DB/19°C WB, Water in: 7°C/12°C, 50 Pa external static pressure.(2) Air: 20°C, Water in: 50°C, same water flow as in cooling, 50 Pa external static pressure.(3) Air: 20°C, Water in: 70°C/60°C, 50 Pa external static pressure.(4) According eurovent standard: Return + radiated sound power level given for a unit with 50 Pa external static pressure in medium speed.(5) Sound pressure considering an hypothetical installation and local attenuation of 21 dB.
list of options is available page 50. list of accessories is available page 51.
50
Commercial Air Conditioning |
51
230 V THERMAL TyPE ON/OFF VALVE 03 05 07 10 15 18 21 24 27
W2g1 2way type, one valve for one coil W2G1
W2g2 2way type, two valves for two coils W2G2
W4g1 4way type, one valve for one coil W4G1
W4g2 4way type, two valves for two coils W4G2
CONTROL
Eco 3 Ecospeed card for EC motorPco Mechanical sensor for automatique change over
aQuanEt Aquanet controllerniu µBMS compatible communication board NIU for Aquanet
Eniu Modbus communication board eNIU for Aquanet
FILTER
g3 G3 filter (85%)g4 G4 filter (90%)
ELECTRICAL HEATER 03 05 07 10 15 18 21 24 27
BE1 600 W 500 W 1000 W 1000 W 1000 W 1000 W 1000 W 1000 W 1000 WBE2 800 W 750 W 1500 W 1500 W 2000 W 2000 W 2000 W 2000 W 2000 WBE3 1200 W 1000 W 2000 W 2000 W 3000 W 3000 W 3000 W 3000 W 3000 WBE4 1400 W 1500 WBE5 1600 W 2000 W
AIR INLET AND AIR OUTLET CONFIGURATION 03 05 07 10 15 18 21 24 27
no fresh airAI Rect./AO Rect.
AI Rect./AO 2xø160mm
AI 2xø160mm/AO 2xø160mm
AI Rect./AO 2xø200mm
AI 2xø200mm/AO 2xø200mm
AI 2x ob éq ø250mm/AO 2x ob éq ø250mm
AI Rect./AO 3xø200mm
AI 3xø200mm/AO 3xø200mm
AI 3x ob éq ø250mm/AO 3x ob éq ø250mm
AI Rect./AO 3xø250mm
AI 3xø250mm/AO 3xø250mm
With fresh airAI Rect./AO Rect.
AI Rect./AO 2xø160mm
AI 2xø160mm/AO 2xø160mm
AI Rect./AO 2xø200mm
AI 2xø200mm/AO 2xø200mm
AI 2x ob éq ø250mm/AO 2x ob éq ø250mm
AI Rect./AO 3xø200mm
AI 3xø200mm/AO 3xø200mm
AI 3x ob éq ø250mm/AO 3x ob éq ø250mm
AI Rect./AO 3xø250mm
AI 3xø250mm/AO 3xø250mm
OTHER OPTIONS
Fuse HolderElectrical heater relayAuxiliary Drain PanDouble Skin M0 ERPDrain pumpIndividual packaging
options
50 51
ACCESSORIES 03 05 07 10 15 18 21 24 27
trM-VP Remote thermostat withsummer/winter manual switch - action on control valve Code 7ACEl1443
trM-FaRemote thermostat withsummer/winter manual switch - action on control valve and fan
Code 7ACEl1440
taE20 Electronic thermostat TAE20 Code 7ACEl1451
taE20+SEH Electronic thermostat TAE20 + change over sensor Code 7ACEl1452
SEH Change over sensor for TAE 20 Code 7ACEl1233aQuaSiMP Aquasimp controller for wall mounting Code 7ACEl1546
WPt for aQuaSiMP
Water probe for Aquasimp Code 7ACEl1547
aQuanEt Aquanet control Code 7ACEl1432rcl RCl remote control Code 7ACEl1445
µBMS µBMS supervisor Code 7ACEl1448
niu µBMS compatible communication board NIU for Aquanet Code 7ACEl1462
eniu Modbus communication board eNIU for Aquanet Code 7ACEl1463
ir rec Wall IR receiver for Aquanet (Aquanet not included) Code 7ACEl1364
Prc Drain pump Code 7ACEl1346Suspension kit Code 7ACTl0486Auxilliary drain pan Code 7ACTl0096
230 V THERMAL TyPE ON/OFF VALVE 03 05 07 10 15 18 21 24 27W2g1 2-way type, one valve for one coil - W2G1 Code 7ACFH0619 7ACFH0620 7ACFH0621 7ACFH0622 7ACFH0623 7ACFH0623 7ACFH0624 7ACFH0624 -
W2g2 2-way type, two valves for two coils - W2G2 Code 7ACFH0625 7ACFH0626 7ACFH0627 7ACFH0628 7ACFH0629 7ACFH0629 7ACFH0630 7ACFH0630 -
W4g1 4-way type, one valve for one coil - W4G1 Code 7ACFH0607 7ACFH0608 7ACFH0609 7ACFH0610 7ACFH0611 7ACFH0611 7ACFH0612 7ACFH0612 -
W4g2 4-way type, two valves for two coils - W4G2 Code 7ACFH0613 7ACFH0614 7ACFH0615 7ACFH0616 7ACFH0617 7ACFH0617 7ACFH0618 7ACFH0618 -
accessories
52
Commercial Air Conditioning |
53
Aqu@beamcHillEd BEaM - cooling and HEating
cooling capacity: up to 1.2 kW/ml Heating capacity: up to 1.2 kW/ml
SIzeS: 1W: 6 sizes 2W: 9 sizes 4W: 3 sizes
VeRSIONS: 2-Pipes 4-pipes
CONFIGURATIONS: 1W - 1-way air diffusion 2W - 2-way air diffusion 4W - 4-way air diffusion
PRODUCT ADVANTAGES High induction active chilled beam. innovative technical solution for architectural installations. attractive aesthetic and harmonious design. designed for suspended ceiling integration (2W and 4W) or under ceiling (1W). Fit for 600 mm frame width. Homogeneous air distribution with coanda effect. individual adjustable airflow. High cooling capacity. optimized primary air pressure. Very low operating acoustical levels. galvanized steel sheet with special primary air duct and internal balanced air diffuser. Maintenance-free.
MAIN OPTIONS adjustable fixing brakets. Fix or adjustable nozzle. Hot water coil for 4-pipe system. Standard or high capacity coil (4W version). coupling diameter and position. Electronic control with either BMS, ir or wall-mounted thermostat. condensation sensor. Manual or motorized primary air controller. 2-way or 3-way on/oFF valve. integrated light.
MAIN ACCESSORIES aqu@net control. room thermostat.
Operating limit fOr Standard unit
Minimum water temperature +14°C
Maximum water temperature +50°C
Maximum operating pressure 10 bars
Indoor air temperature(room/intake/around unit)
Temperature and relative humidity such that
the system can operate without condensation.
Primary air temperature 15 to 22°C
52 53
aQB model 1w 2w 4wCAPACITIES NOMINAL
Cooling capacity (1) W/ml …600 …800 …1200Heating capacity (2) W/ml …800 …1000 …1200
PRIMARy AIR (MIN…MAx)
Primary air static pressure Pa 50…150
Airflow m³/h/ml 20…70 28…146 25…213SOUND LEVELS (MIN…MAx)
Sound pressure level (3) dB(A) 20…29 20…30 20…33WATER CONNECTIONS
Type SmoothCooling coil mm 12/15 12/15 12/15Heating coil mm 12 12 12
DIMENSIONS (MIN…MAx)
Width mm 440 592 592Height mm 200 170/190 225lenght mm 1200….2700 600…3000 600…1800
WEIGHT (MIN…MAx)
Unit weight kg 24…51 12…57 16…44
(1) Air: 26°C DB, Primary air: 16°C/100Pa, Water in: 14°C/18°C.(1) Air: 20°C DB, Primary air: 20°C/100Pa, Water in: 50°C/40°C.(3) Sound pressure considering a local of 100m³, a reverberation time of 0,5 sec and a distance of 1 m.
PRODUCT CODE SIzE 06 09 12 15 18 21 24 27 30
4-way type 1 4w-06 4w1-12 4w1-18
Haute capacité2-Pipes
4-Pipes4-way type 2 4w2-12 4w2-18
Standard2-Pipes
4-Pipes
2-way 2w-06 2w-09 2w-12 2w-15 2w-18 2w-21 2w-24 2w-27 2w-302-Pipes
4-Pipes
Adjustabel nozzle
1-way 1w-12 1w-15 1w-18 1w-21 1w-24 1w-27 1w-302-Pipes
4-Pipes
Adjustabel nozzle
OPTIONS
valve
2 Ways 1 valve 2-ways 3 Ways + Bypass 1 valve 3-ways + bypass
regulation
With Controller *1- BMS only2- Thermostat inside3- IR control4- Wall-mounted thermostatCondensate sensor
* Condensate sensor included
ACCESSORIES
24V dc Power supplyprimary air damper
Manual Ø 100 mmManual Ø 125 mmMotorized Ø 100 mmMotorized Ø 125 mm
54
Commercial Air Conditioning |
55
Large choice of options and features
Air treAtment becomes A technology
EC plug fanon Slim@irrange
High efficiency gas burneron RoofTech range
Control factory mountedon Eff@ir, Rooftop, ...
Heat recovery systemby plate heat exchanger, thermal wheel, heat pipes, or, run around coils
Economiser on RoofT@ir andRoofTech ranges
Class A reachable on Premi@ir and @irTwin range
Filter from G1 to H14 according to EN 779 andEN1822
Weather hood included in all fresh air options on RoofTops, completelyretractable to save place on the truck
Large choice of coils…Water and DX coils with Aluminium, or, Epoxy, or, Copper fins
High efficiency IE2 motors on @irTwin, Premi@ir, Rooftop and Wespak 4, 5 & 6.
Scroll or rotary type hermetic compressor onRooftop ranges
Extractable drain pan or 3-sloped dry drain pan for hygienic environment on Premi@ir range
AIR HANDLING UNITS & ROOFTOPS
air
Ha
nd
lin
g U
nit
s a
nd
ro
oFt
op
s R
An
Ge
Wespak Slim@ir Premi@ir @irTwinup to
30 000 m³/h
@irTwinup to
100 000 m³/h
Eff@irHAN
RoofT@irRoofTech
R410A
Shopping centers
Offices
Health
Navy
Industry
Tertiary
54 55
EfficiEnt production facilitiEs in pons and tillièrEs iso 9001:2008 factoriEs
Several selection software with a user-friendly graphic interface…WinClim, eClim, eRoof, WinPak…
1 CNC Panelling Line (automatic Punching + Bending) 8 CNC Punching machine 17 CNC Bending machine 5 coils assembly line 8 AHUs assembly lines 2 RoofTops assembly lines
a large range to fulfil all reQuirements…
Wespak... Direct drive compact air handling units designed, in a modular construction, with a single or double skin construction, with 10 mm foam insulation (fire protection class M1). Available in horizontal or in vertical configuration.
Slim@ir... Self-supporting construction with double skin panels 25 mm thick, Slim@ir is an air handling unit really compact and ultra adaptable, L1-D1-T3-TB3-F9 conform regarding EN1886 and designed to cover all market needs with various arrangements possible: single flow in line, double flow in line, side by side, superposed, vertical, and outdoor installation.
Premi@ir... 10 models, from 1’000 to 30’000 m³/h, adapted for comfort, hygienic & Industrial applications with an innovative, robust 50mm self-supporting construction with a perfectly smooth tunnel, including at the module junction points, thus avoiding any microbial growth due to dust build-up.
RoofTech... Pre-assembled weatherproof single package, designed to save energy and for long life durability thanks to an efficient aluminium casing (less weight) double wall designed for roof, floor, doors and side panels in order to prevent insulation fibber from entering the building and from harmful build-up of bacteria or contaminants.
Eff@ir... Double skin (injected foam) 25 mm for medium efficiency or 40 mm for high and very high efficiency (90%), vertical or horizontal mode, Multi-configurations, and, with or without controls solutions, eff@ir range permit to fulfil the highest requirement in term of energy saving.
eClim selection software:
The eCLIM selection software is a selection tool with 3D view allowing users to select the Slim@ir AHU compact air handling units.
Intuitive, user-friendly, fast and efficient, eCLIM allows the users:
To select and visualize a unit, To represent a unit as scaled 3D model, To change and configure components, To automatically generate 2D/3D drawings in DXF format, selection sheets including the complete technical data and prices, as well as a manufacturing entry form.
eCLIM uses a high-performance visual interface, indeed the user can see exactly what he does and the modifications carried out are taken instantaneously into account in the visualized model.
The innovative procedure of eCLIM selection software allows even the operators less experienced to select, design and establish prices of complicated air handling units.
The user can add, modify, move or delete components by a simple click of mouse.
Premi@ir
RoofTech
56
Commercial Air Conditioning |
57
Wespak 1.39 to 3.99air Handling unit For FalSE cEiling aPPlication
Water cooling capacity: from 4 kW (4r at 500 m³/h) to 33 kW (6r at 4000 m³/h)
Water Heating capacity: from 9 kW (at 500 m³/h) to 51 kW (at 4000 m³/h)
Sizes: 3 airflow range: from 500 to 4400 m³/h (fan alone) insulation: Foam 10mm
DESCRIPTION Wespak direct drive compact air handling units are designed, in a modular construction, to meet the heating and air conditioning requirements of all medium-size areas. Single or double skin construction manufactured from 1.2 mm thick galvanized sheet steel (painting on external skin can be supplied as optional), with 10 mm open cell foam insulation (fire protection class M1). available in horizontal or in vertical configuration.
PRODUCT ADVANTAGES their low height, only 370 mm, facilitates easy integration within false ceilings. Easy maintenance: right hand or left hand side access to internal components. Filter access from all four sides is available as an option. components fixed on a sliding mounting rail for easy maintenance (except for the cooling coil in vertical arrangement). Various arrangement possible.
MAIN FUNCTIONS Fans: centrifugal fans with one or two impellers driven directly by a 3-speed motor, 230/1/50 Hz, insulation class F with an automatic reset internal overheat protection.
Two types of filters:- Synthetic type with g2 or g4 efficiency. Fire class M1 at clean conditions. - Metallic type with g1 efficiency. Fire class M0 at clean conditions.
Coils: 2-rows (heating coils) or 4-rows coils (water or direct expansion cooling coils) or 6-rows (water cooling coils), with copper tubes and aluminium fins. coils can be fitted with optional moisture eliminator to give protection against high humidity or high air velocity.
all ceiling (or wall) mounted unit arrangement are not possible, consult technical manual for feasibility.
Some prohibited applications: Electric heating coil BE3 upstream of fan Heating coil upstream of fan when off-coil temperature exceeds 50°c. Electric heating coil within VM49 section
Unsuitable arrangements: M³9 - M59 - M83 - M93 arrangements, if 100 % fresh air of winter season is flowing directly on chilled water coil (without glycol solution) located upstream of heating coil. use of fan section when the external resistance is below 50 Pa.
MAIN OPTIONS 2-way mixing box with face and top dampers (Md1), or, top and bottom dampers (Md2). in line 3-way mixing box with top dampers, or, superposed 3-way mixing box with top dampers (Md3). double skin casing panel (dP), 10mm thick. ral 9010 external painting (Pt). air-to-air heat recuperator on superposed configuration (rP). Parallel blade shut-off damper (ag). 10 mm metallic filter with g1 efficiency replacing standard filter (FM1). External filter section with: 10 mm metallic, g1 efficiency (Fa1); 10 mm synthetic, g2 efficiency (Fa2); 50 mm synthetic, g4 efficiency (Fa3).
two-way discharge air plenum (PlE). 90° discharge air plenum (r). inlet duct collar (ca). Flexible connection for inlet side, outlet side or mixing boxes (M). Silencer (PaS). Weather hood (aP) and roof (to).
MAIN ACCESSORIES Fan 3-speed switch (cMVM). remote control including summer/winter change-over, room thermostat, on/off, and fan 3-speed switch. With, valve and fan cycling action (trM-Fa), or, valve cycling only action (trM-VP). droplet eliminator (metallic filter).
Operating limit/recOmmendatiOns
56 57
wespaK - wp 1.39 2.69 3.99airflow m³/h 1010 1340 1680 1650 2200 2750 2220 2960 3710
air velocity on cooling coil m/s 1.5 2.0 2.5 1.5 2.0 2.5 1.5 2.0 2.5Height (in line) mm 370 370 370
Height (superposed) mm 740 740 740Width (in line or superposed) mm 762 1150 1500
Width (side by side) mm N/A N/A N/ACOILS
rows 2 rows in heating - 4 & 6 rows in water cooling - 4 rows in direct expansion coilFin spacing for water coils mm 2.1
airflow m³/h 1010 1340 1680 1650 2200 2750 2220 2960 3710total cooling capacity (4rows) kW 7.4 9.4 11.3 12.0 15.3 18.3 16.3 20.7 24.6
Sensible cooling capacity (4rows) kW 5.3 6.9 8.4 8.7 11.3 13.7 11.7 15.1 18.3total cooling capacity (6rows) kW 9.1 11.7 14.2 14.8 19.3 23.5 19.9 25.6 30.9
Sensible cooling capacity (6rows) kW 6.1 8.0 9.7 10.0 13.1 16.1 13.4 17.5 21.3cooling coil connection (4rows) DN 26/34 26/34 26/34
Heating capacity (2rows) kW 15.9 19.7 23.1 26.0 32.2 37.8 33.6 41.6 48.8Heating coil connection (2rows) DN 26/34 26/34 26/34
Electric Heater capacity min kW 3.0 6.0 12.0Electric Heater capacity max kW 9.0 18.0 36.0
FAN MOTOR ASSEMbLy
type available centrifugal fan direct driveQuantity of fans 1 2 2
absorbed power W 700 960 900nominal power of motor W 250 368 540
intensity max A 3.30 4.22 5.01FILTER
Frame sliding railsFilter available Synthetic filters G2 (10mm) & G4 flat (50mm) according EN779
ExTERNAL STATIC PRESSURE
airflow m³/h 1010 1340 1680 1650 2200 2750 2220 2960 3710g2 filter + Fan (HM8) Pa 254 (MS) 256 (HS) 192 (HS) 227 (MS) 234 (HS) 162 (HS) 250 (lS) 249 (HS) 169 (HS)
g2 filter + Heat. coil 2r + Fan (HP6) Pa 243 (MS) 237 (HS) 164 (HS) 216 (MS) 215 (HS) 134 (HS) 239 (lS) 230 (HS) 141 (HS)g2 filter + cool. coil 4r + Fan (HP7) Pa 216 (MS) 193 (HS) 96 (HS) 189 (MS) 170 (HS) 65 (HS) 213 (lS) 186 (HS) 73 (HS)
g2 + Heat. coil 2r + cool. coil 4r + Fan (HP4) Pa 205 (MS) 174 (HS) 68 (HS) 179 (MS) 151 (HS) 37 (HS) 202 (lS) 167 (HS) 44 (HS)HEAT RECOVERy (SUPERPOSED CONFIGURATION ONLy)
airflow m³/h 1010 1340 1680 1650 2200 2750 2220 2960 3710thermal plate std efficiency (Hum/dry) % 40.7/45.7 39.1/43.8 37.7/42.2 40.7/45.6 39.0/43.7 37.7/42.2 40.7/45.6 39.0/43.7 37.7/42.2
Pressure drop Fresh air/return air Pa 46/49 73/79 107/115 45/49 74/79 107/115 45/49 73/79 106/115
Cooling capacity based on air temperature of 27°C/50% and water temperature of 7/12°C.Heating capacity based on air temperature of 15°C and water temperature of 90/70°C (coil at the discharge side).Thermal Plate efficiency based on fresh air temperature of -7°C/90% - 22°C/50%.LS = Low Speed, MS = Medium Speed, HS = High Speed.Others characteristics and details: consult Technical Manual (eDM).
Arrangement HM8 Arrangement HP6 Arrangement HP7 Arrangement HP4
58
Commercial Air Conditioning |
59
Wespak 4.05 to 6.05air Handling unit For FlaSE cEilling aPPlication
Water cooling capacity: from 22 to 59 kW (6 rows at 8410 m³/h)
Water Heating capacity: from 39 to 80 kW Sizes: 3 airflow range: from 3700 to 9000 m³/h (fan alone) insulation: Foam 10mm/glasswhool 25 mm
DESCRIPTION the Wespak units offer an extension in their range, designed to meet the market demands. this extension comprises a range of belt drive compact air handling units with low silhouette suitable for hanging above the false ceiling. these units are intended either for new installations or for retrofit applications.
PRODUCT ADVANTAGES the Wespak belt drive compact air handling units come in 3 sizes covering an air flow range from 4000 to 9000 m³/h. the units are fitted, as standard, with adjustable pulley allowing for operation with maximum static pressure or for air volume balancing for proper operation. Single wall (with 10 mm thick synthetic foam) or double wall construction (with 25 mm thick glass filter insulation) for cleanability of unit interior.
MAIN FUNCTIONS Fans: Each fan is of double inlet high efficiency centrifugal type with forward curved blades. Fans are driven by belt by a tEFc, 1500 nominal rPM, class F, iP55, 400 V/3 Ph/50 Hz motor mounted on an adjustable platform to facilitate belt adjustment. Filters: they are available in two efficiencies: 10 mm thick g2 and 50 mm thick g4 filters. Filters are mounted in external box and are supplied in several elements for ease of removal.
Coils: 2-rows (heating coils) or 4-rows coils (water or direct expansion cooling coils) or 6-rows (water cooling coils), with copper tubes and aluminium fins. coils can be fitted with optional moisture eliminator to give protection against high humidity or high air velocity.
Wall mounted unit arrangement are not possible.Prohibited applications:
Electric heating coil BE3 upstream of fan. Heating coil upstream of fan when off-coil temperature exceeds 50 °c. Electric heating coil within VM49 section.
Unsuitable arrangements: M³9 - M59 - M83 - M93 arrangements, if 100 % fresh air of winter season is flowing directly on chilled water coil (without glycol solution) located upstream of heating coil. use of fan section when the external resistance is below 50 Pa.
MAIN OPTIONS 2-way mixing box with face and top dampers (Md1), or, top and bottom dampers (Md2). in line 3-way mixing box with top dampers, or, superposed 3-way mixing box with top dampers (Md3). double skin casing panel (dP), 25 mm thick. air-to-air heat recuperator on superposed configuration (rP). Parallel blade shut-off damper (ag). External filter section with: 10 mm synthetic (Fa1), g2 efficiency (Fa2); or; 50 mm synthetic, g4 efficiency (Fa3).
two-way discharge air plenum (PlE). 90° discharge air plenum (r). inlet duct collar (ca). Flexible connection for inlet side, outlet side or mixing boxes (M). Silencer (PaS).
MAIN ACCESSORIES Fan 3-speed switch (cMVM). remote control including summer/winter change-over, room thermostat, on/off, and fan 3-speed switch. With, valve and fan cycling action (trM-Fa), or, valve cycling only action (trM-VP). droplet eliminator (metallic filter).
Operating limit/recOmmendatiOns
58 59
wespaK - wp 4.05 5.05 6.05airflow m³/h 3730 4660 5600 4940 6180 7410 5600 7010 8410
air velocity on cooling coil m/s 2.0 2.5 3.0 2.0 2.5 3.0 2.0 2.5 3.0Height (in line) mm 485 485 540
Height (superposed) mm 970 970 1080Width (in line or superposed) mm 1550 1990 1990
Width (side by side) mm N/A N/A N/ACOILS
rows 2 rows in heating - 4 & 6 rows in water cooling - 4 rows in direct expansion coilFin spacing for water coils mm 2.1
airflow m³/h 3730 4660 5600 4940 6180 7410 5600 7010 8410total cooling capacity (4rows) kW 22.4 26.6 30.4 31.9 37.5 42.6 36.1 42.5 48.3
Sensible cooling capacity (4rows) kW 15.6 18.6 21.4 21.7 25.7 29.4 24.6 29.1 33.3total cooling capacity (6rows) kW 26.7 32.2 37.3 37.9 45.4 52.4 42.9 51.5 59.3
Sensible cooling capacity (6rows) kW 18.5 22.3 26.1 25.7 31.0 35.8 29.1 35.1 40.7cooling coil connection (4rows) DN 33/42 33/42 33/42
Heating capacity (2rows) kW 39.6 46.0 51.9 53.8 62.7 70.7 61.0 71.0 80.2Heating coil connection (2rows) DN 33/42 33/42 33/42
Electric Heater capacity min kW 12.0 24.0 36.0Electric Heater capacity max kW 36 (1) 48 (1) 60 (1)
FAN MOTOR ASSEMbLy
type available Double wheel centrifugal belt driven by motors IP55 - F - 400V/3ph/50Hz - 1500rpmQuantity of fans 2 2 2
absorbed power kW 1.7 2.5 2.5nominal power of motor kW 1.5 2.2 2.2
intensity max A 3.45 4.80 4.80FILTER
Frame Sliding railsFilter available Synthetic filters G2 (10mm) & G4 flat (50mm) according EN779
HEAT RECOVERy (SUPERPOSED CONFIGURATION ONLy)
airflow m³/h 3730 4660 5600 4940 6180 7410 5600 7010 8410thermal plate std efficiency (Hum/dry) % 43.6/49.1 42.6/47.8 46.8/41.7 43.4/48.8 42.3/47.5 41.4/46.5 42.8/48.1 41.7/46.8 40.8/45.8
Pressure drop Fresh air/return air Pa 73/78 105/113 143/154 74/79 107/115 145/156 91/98 132/142 179/193
Cooling capacity based on air temperature of 27 °C/50% and water temperature of 7/12 °C.Heating capacity based on air temperature of 15 °C and water temperature of 90/70 °C (coil at the discharge side).Thermal Plate efficiency based on fresh air temperature of -7°C/90% - 22°C/50%.Others characteristics and details: consult Technical Manual (eDM).
Arrangement HM8 (FA + HM9C) Arrangement HP6 (FA + HP0) Arrangement HP7 (FA + HP1) Arrangement HP4 (FA + HP2)
60
Commercial Air Conditioning |
61
Slim@ir 0303 to 0318air Handling unit For FalSE cEiling aPPlication
Water cooling capacity: from 3 to 38 kW Water Heating capacity: from 8 to 108 kW Electrical Heating capacity: from 1 to 54 kW Sizes: 6 airflow range: from 500 m³/h (1.5 m/s) to 6000 m³/h (3.1 m/s on coil)
insulation: glass wool & rockwool
DESCRIPTION Self-supporting construction with double skin panels 25 mm thick, Slim@ir is an air handling unit really compact and ultra adaptable designed to cover all market needs with various arrangements possible: single flow in line, double flow in line, side by side, superposed, vertical, and outdoor installation. a concentrate of innovation and technology adapted to the same rules and constraints than those required on the main air handling units with performing En 1886 classification t3 - tB3 - l1 - F9 - d1 (tested by independent tuV laboratory).
PRODUCT ADVANTAGES With 6 models, from 500 to 6’000m³/h, fully adapted for all applications, thanks to a powerful casing with a large and full accessibility on internal components; by the side with hinged doors, by the bottom with hinged doors, or, by the bottom with trapdoors on chassis; place the Slim@ir among the most powerful air handling unit for false ceiling application currently on the market. the Slim@ir aHu is also suitable for hygienic environments thanks to a l1 classification (En1886) and a inner tunnel completely smooth and easy to clean, and, with removable drain pan in standard. an innovative selection software with a user-friendly 3d graphic interface allowing all types of simulations and giving technical datas and execution drawings.
MAIN FUNCTIONS Plates heat exchanger, Eurovent certified, available in side by side and superposed configuration allowing to recover 50% or up to 80% of energy in accordance with calculations of the European standard En 308. Plug-fan associated high efficiency motors (iE2 or Ec), for increased performances and low consumption and noise levels, supports the respect of the requirements imposed on the buildings known as of “low consumption”.
a powerful compression system, F9 conform (En1886), per butterfly screws that ensures a perfect sealing whatever of the thickness tolerance of the filter.
+/- 1000 Pa of total pressure. -20°c min and 40°c max. according to inner air temperature and outdoor air temperature, condensation can appear on panels.
MAIN OPTIONS 2 types of plate heat exchanger (~50% & ~80% efficiency). glass wool or rock wool insulation type. large choice of filter from g4 flat filter to F9 long bag filter. Heating coils 1, 2 or 3 rows with a fin spacing of 2.1mm. cooling coils 3, 4 or 6 rows with a fin spacing of 2.5mm. Stainless steel aiSi 304l or aiSi 316l drain pan on cooling coil.
Water coils with copper tubes and aluminium, epoxy or copper fins. 5 electrical coil capacity per size from 1kW (1ph) to 54 kW (3ph). Sliding rails, blank-off metal sheet and components’ frame in aiSi 304l or 316l. a choice of 3 types of dampers: Standard, airtight class 3 and airtight class 4 according En 1751.
1-way, 2-ways and 3-ways mixing section. Sound attenuator 300mm, 600mm, 900mm and 1200mm long. Plug-Fan 3~ with wheel epoxy coated, and, Epoxy fan metal sheet. End panel with circular plenum. double deflection discharge plenum. 90° angle discharge nozzle.
MAIN ACCESSORIES antifreeze thermostat. droplet eliminator galvanized or Stainless steel 304l (metallic filter 25mm thick). angle metallic duct connector (galvanized, 304l or 316l). Metallic connector with flange (galvanized, 304l or 316l). Pressure tapping points. u-tube and inclined manometer. differential pressure switch and magnehelic differential pressure gauge. Standard Flexible flange and EVS-80 Se Hygienic Flexible flange cl.c. Sand trap louver. Weather hood. Frequency inverter iP 20 or iP 55. iP 54 Proximity switch factory mounted. iP 54 actuators 24V or 230V on/off, and, 0-10V - 24Vac/dc. aqu@net control (System a, B, c, d & E), with rcl and others accessories.
Operating limit/recOmmendatiOns
new
60 61
slim@ir - sr 0303 0306 0309 0312 0315 0318airflow (at 2.7 m/s on cooling coil) m³/h 890 1680 2580 3490 4370 5270
Height (in line - side access) mm 400 400 400 400 400 400Height (in line - bottom hinged doors access) mm 430 430 430 430 430 430
Height (in line - bottom trapdoors access) mm 480 480 480 480 480 480Height (superposed - side access) mm 850 850 850 850 850 850
Width (in line or superposed - side access) mm 509 774 1079 1384 1689 1994Width (side by side - side access) mm 1314 1844 2454 3064 3674 4284
COILS
rows 1. 2 & 3 rows in heating coils - 3. 4 & 6 rows in cooling coilFin spacing for water coils mm 2.1mm for heating coils - 2.5mm for cooling coils
total/Sensible cooling capacity (3rows) kW 3.1/3.1 6.2/6.1 9.6/9.4 13/12.7 16/15.8 19.8/19.3total/Sensible cooling capacity (6rows) kW 6.8/5.1 13/9.7 19.8/14.8 27/20.1 33.5/25 38.3/29.3
total Heating capacity (1row) kW 8.7 16.5 25.6 34.7 43.6 53.4total Heating capacity (3rows) kW 18.4 34.9 53.5 72.0 89.6 108.5
Electric Heater capacity min (1 step/1~230V) kW 1.0 2.0 3.0 4.0 5.0 6.0
Electric Heater capacity max (3 steps/3~400V) kW 9.0 18.0 27.0 36.0 45.0 54.0
FAN
type Plug-fan direct driven by motors IP55 - F - 400V/3ph/50Hz - 3000rpm - IE2 (for motor higher than 0.75kW)
Quantity of fans 1 1 1 2 2 2Maximum absorbed power kW
nominal power of motor kW 1.1 1.5 2.2 3.0 3.0 4.4intensity max A
type Plug-fan direct driven by EC motorsQuantity of fans 1 1 2 2 3 3
Maximum absorbed power kWnominal power of motor kW 0.70 0.70 1.40 1.40 2.10 2.10
intensity max A 3.0 3.0 6.0 6.0 9.0 9.0FILTER
Frame Sliding rails
Filter available G4/F5/F7/F9 flat (50mm) - F7/F9 short bag (305mm) - F7/F9 long bag (500mm) - F7/F9 compact (292mm)*
HEAT RECOVERy
airflow m³/h 890 1680 2580 3490 4370 5270thermal plate std efficiency
(Hum/dry) En308 % 48.8/52.7 46.1/50.9 46.2/50.9 47.4/52.6 49.1/53.7 48.6/52.9
Pressure drop Fresh air/return air Pa 126/112 169/150 177/158 216/192 112/106 117/110Module length mm 720 1040 1280 1440 720 720
thermal plate high efficiency (Hum/dry) En308 % 82.4/91.2 80.8/90 80.1/89.5 79.8/89.3 79.5/89.1 79.4/89.0
Pressure drop Fresh air/return air Pa 69/84 104/129 127/157 140/173 150/185 156/193Module length mm 960 960 960 960 960 960
STD Delivery time: without factories load.Cooling coil performance for 32°C/40% - 7/12°C & Heating coil performance for -7°C/90% - 90/70°C* not available on all the sizesOutdoor configuration: Side access only (casing height (without base frame) = 425mm )DN 20 on all heating and cooling coilsThermal Plate efficiency based on fresh air temperature of -7°C/90% - 22°C/50%
62
Commercial Air Conditioning |
63
Eff@irWR-I 1000-5000air Handling unit
airflow range: from 1000 to 5000 m³/h Sizes: 5 insulation: 40mm - polyurethane foam Efficiency: 75 to 86%
DESCRIPTION High efficiency heat recovery ventilators with aluminium rotary heat exchanger in horizontal or vertical configuration, efficiency from 75% up to 86%, with extruded alloy aluminium profiles and a casing in double skin plasticized steel panels, sandwiched on injected polyurethane foam insulation 42 kg/m³, 40 mm thick. available in four configuration: Standard, with electric heater, with post-heating/cooling water coil, or, with direct expansion coil r410a (to be connected to a remote heat pump not supplied).
PRODUCT ADVANTAGES Suitable solution to achieve the highest energy certification for commercial, industrial and residential collective buildings. Filtration g4 (En779) for exhaust air and F7 (En779) low pressure drop for fresh air.
Plug-n-play solutions with electrical panel and microporocessor control pre-wired on board. Horizontal and vertical configuration. 100% by-pass for automatic free-cooling. circular spigots on inlet and outlet panels. conform ErP-2015.
installation allowed inside the buildings or outdoor, with temperature between -15 to +50°c. avoid areas near sources of heat source, steam, flammable and/or explosives gases, dusty areas. according to inner air temperature and outdoor air temperature, condensation can appear on panels. units not adapted for specific environment (Marine, etc...).
MAIN OPTIONSConstant or variable speed wheel rotation with: VaV: variable air volume (available with indoor air quality control co2 or co2/Voc or humidity control). Setting with independent control of the air fluxes (balancing/unbalancing). ask to the technical office. caV: constant air volume. coP: constant pressure.
Accessories for air filtration: F9 optional filter low pressure loss.
Pre-heating of inlet air.
MAIN ACCESSORIESOptional microprocessor controls (see the Accessories booklet): ctr07 EVo PH EVo d PH
Optional sensors (for VAV setting only): EE80 co2 sensor. QPa 2002 co2/Voc air quality sensor. EE16 Humidity sensor.
Protective accessories: SKMF-r Weather protection cowl. t Weather protective roof (for horizontal configuration only).
Operating limit/recOmmendatiOns
new
62 63
eff@ir wr-i 1000 2000 3000 4000 5000airflow m³/h 400 800 1400 1700 2100
available pressure Pa 190 330 280 240 310Wheel Efficiency % 86 86 86 86 86
airflow m³/h 1000 2000 3000 4000 5000available pressure Pa 120 230 160 190 130
Wheel Efficiency % 76 76 77 76 75Fan* Power W 300 550 750 1500 1500
Fan* Power supply (3ph-50Hz) 230/400V 400V 230/400VFan* current max A 2.4/1.4 4.3/2.5 3.1A 9.7/5.6 9.7/5.6
Fan* Protection/insulation class A IP 55/ Class Funit Power supply 230V-1ph-50Hz 400V-3ph-50Hz
unit current max A 5 9 7 12,6 12,6unit Protection/insulation class A IP 20
POST-HEATING/COOLING WATER COIL (1)
rating kW 5,5 10,3 15,0 23,9 31,0DIRECT ExPANSION R410A (2)
rating kW 5,5 10,0 15,0 23,0 30,0ELECTRIC HEATER (3)
nominal power kW 4,0 6,0 8,0 12,0 12,0tension/Phases 230V-1ph-50Hz 400V-3ph-50Hz
absorbed current A 17,5 26,0 11,6 17,3 17,3Stages 2
absorbed current A 16,6 26,0 11,6 17,3 17,3DIMENSION AND WEIGHT IN VERTICAL CONFIGURATION
Height (with base frame) mm 1280 1480 1780 1880 1980Width mm 680 880 1080 1180 1280
length mm 1680 1680 1850 2000 2200Weight kg 215 295 370 425 500
DIMENSION AND WEIGHT IN HORIzONTAL CONFIGURATION
Height (with base frame) mm 1030 1030 1230 1330 1430Width mm 680 880 1080 1180 1280
length mm 1680 1680 1680 1880 1980Weight kg 195 265 320 365 430
NOISE LEVEL (4)
lw Vmax transmitted dB(A) 59 66 67 67 69lw Vmin transmitted dB(A) 55 47 57 53 54
lw Vmax radiated dB(A) 55 55 63 62 63lw Vmin radiated dB(A) 52 48 53 48 50
* Values referred for a single fan.(1) Specifical thermal yeld are available. Please, contact our technical department . Given for 7/12°C on water - 3 Rows - pitch pipes P60.(2) external air 34°C relative humidity 50% | Indoor air 27°C relative humidity 45% | Air released inside 20°C relative humidity 92% |
Sub-cooling of 5°C | 3 rows - Pitch pipes 25/22.(3) For external air temperature of -5°C.(4) Lw Sound power level taken in accordance to the UNI eN ISO 3747 (LfA ≥ 7 dB for each measurement position, class 2 accuracy).
Vertical configuration Horizontal configuration
64
Commercial Air Conditioning |
65
Eff@irCF-I 1000-6000air Handling unit
airflow range: from 1000 to 6000 m³/h Sizes: 5 insulation: 40 mm - polyurethane foam Efficiency: from 85 to 93%
DESCRIPTION High efficiency polypropylene modular counterflow plate heat exchanger in horizontal configuration, efficiency from 85% up to 93% with extruded alloy aluminium profiles and a casing in double skin plasticized steel panels, sandwiched on injected polyurethane foam insulation 42 kg/m³, 40 mm thick. avaialble in four configuration: Standard, with electric heater, with post-heating/cooling water coil, or, with direct expansion coil r410a (to be connected to a remote heat pump not supplied by airwell).
PRODUCT ADVANTAGES Suitable solution to achieve the highest energy certification for commercial, industrial and residential collective buildings. Filtration g4 (En779) for exhaust air and F7 (En779) low pressure drop for fresh air. Plug-n-play solutions with electrical panel and microporocessor control pre-wired on board. 100% by-pass for automatic free-cooling. circular spigots on inlet and outlet panels. conform ErP-2015.
installation allowed inside the buildings or outdoor, with temperature between -15 to +50°c. avoid areas near sources of heat source, steam, flammable and/or explosives gases, dusty areas. according to inner air temperature and outdoor air temperature, condensation can appear on panels. units not adapted for specific environment (Marine, etc...).
MAIN OPTIONSConstant or variable speed wheel rotation with: VaV: variable air volume (available with indoor air quality control co2 or co2/Voc or humidity control). setting with independent control of the air fluxes (balancing/unbalancing). ask to the technical office.
caV: constant air volume. coP: constant pressure.
Accessories for air filtration: F9 optional filter low pressure loss.
Pre-heating of inlet air.
Aluminium counterflow plate heat exchanger for application requiring non-combustible material (as for French building Receiving Public).
MAIN ACCESSORIESOptional microprocessor controls (see the Accessories booklet): ctr07 EVo PH EVo d PH
Optional sensors (for VAV setting only): EE80 co2 sensor. QPa 2002 co2/Voc air quality sensor. EE16 Humidity sensor.
Protective accessories: SKMF-r Weather protection cowl. t Weather protective roof (for horizontal configuration only).
Operating limit/recOmmendatiOns
new
64 65
cf-i 1000 2000 3000 4500 6000airflow m³/h 300 600 900 1300 1700
available pressure Pa 430 420 440 640 510Wheel Efficiency (5) % 93 93 93 93 93
airflow m³/h 1000 2000 3000 4500 6000available pressure Pa 110 140 180 200 110
Wheel Efficiency (5) % 85 85 85 85 85Fan* Power W 300 550 750 1500 1500
Fan* Power supply (3ph-50Hz) 230/400V 400V 230/400VFan* current max A 2.4/1.4 4.3/2.5 3.1A 9.7/5.6 9.7/5.6
Fan* Protection/insulation class A IP 55/ Class Funit Power supply 230V-1ph-50Hz 400V-3ph-50Hz
unit current max A 5 9 7 12,6 12,6unit Protection/insulation class A IP 20
POST-HEATING/COOLING WATER COIL (1)
rating kW 5,5 10,3 15,0 23,9 31,0DIRECT ExPANSION R410A (2)
rating kW 5,5 10,0 15,0 23,0 30,0ELECTRIC HEATER (3)
nominal power kW 4,0 6,0 8,0 12,0 12,0tension/Phases 230V-1ph-50Hz 400V-3ph-50Hz
absorbed current A 17,5 26,0 11,6 17,3 17,3Stages 2
absorbed current A 16,6 26,0 11,6 17,3 17,3DIMENSION AND WEIGHT
Height (with base frame) mm 600 800 1080 1080 1310Widht mm 1080 1205 1205 1580 1580
lenght mm 1680 1680 1680 1850 1850Weight kg 165 220 280 355 415
circular spigots diameter inlet/outlet mm 250 315 400 450 500NOISE LEVEL (4)
lw Vmax transmitted dB(A) 66 66 75 75 77lw Vmin transmitted dB(A) 52 47 61 59 60
lw Vmax radiated dB(A) 63 62 69 69 71lw Vmin radiated dB(A) 48 44 56 53 54
Weight kg 195 265 320 365 430NOISE LEVEL (4)
lw Vmax transmitted dB(A) 59 66 67 67 69lw Vmin transmitted dB(A) 55 47 57 53 54
lw Vmax radiated dB(A) 55 55 63 62 63lw Vmin radiated dB(A) 52 48 53 48 50
* Values referred for a single fan.(1) Specifical thermal yeld are available. Please, contact our technical department . Given for 7/12°C on water - 3 Rows - pitch pipes P60.(2) external air 34°C relative humidity 50% | Indoor air 27°C relative humidity 45% | Air released inside 20°C relative humidity 92% |
Sub-cooling of 5°C | 3 rows - Picth pipes 25/22.(3) for external air temperature of -5°C.(4) Lw Sound power level taken in accordance to the UNI eN ISO 3747 (LfA ≥ 7 dB for each measurement position, class 2 accuracy).(5) Values refered to the folowing conditions: T°/HR external air -5°C/80%, T°/HR return air 20°C/50%.
Horizontal configuration
66
Commercial Air Conditioning |
67
Eff@irHP S/HP L 1 to 6HP LS 400 to 3500air Handling unit
Water Heating coil capacity: from 2.2 to 34.5 kW Electric Heating coil capacity: from 2 to 12 kW airflow range: from 400 to 5600 Sizes: 6 (HPS/HPl) - 5 (HPlS)
DESCRIPTIONcommercial heat recovery ventilator (efficiency from 50% up to 70%), horizontal or vertical, available in two mains type:
Version HP S (coils in duct)/HP L (coils in AHU) Extruded aluminium profile structure with rounded corners. double skin steel panels, plasticized white, sandwiched on injected polyurethane foam insulation, thickness 25 mm. Side/beneath access for inspection and maintenance. Pressure sockets to measure the filters loss of pressure. condensation drainage system.
Version HP LS (by-pass integrated in AHU) Self-supporting casing made of galvanized steel. reduced height dimensions allowing an easy installation in false ceiling. Side access for inspection and maintenance. condensation drainage system. Simple skin panels:- steel panels thickness 10/10 mm,- external coating with adhesive thermoacustic insulating polyethylene
thickness 5 mm. double skin sandwich panels:- self-supporting galvanized steel with internal rockwool insulation
thickness 25 mm, density 110 kg/m³.
PRODUCT ADVANTAGES Suitable solution for ventilation of commercial buildings available:- without regulation,- Plug & Play solutions with electrical panel pre-wired and
microprocessor control mounted on board.
installation allowed inside the buildings or outdoor, with temperature between -15 to +50°c. avoid areas near sources of heat source, steam, flammable and/or explosives gases, dusty areas. according to inner air temperature and outdoor air temperature, condensation can appear on panels. units not adapted for specific environment (Marine, etc...).
MAIN OPTIONSFor deicing and/or post-heating for duct mounting: rcF-Sc: electric heater. rcFE-Sct: electric heater with electronic regulation. rcF-Scttc: electric heater with thermostatic regulation. Ba-ac: hot water coil (80°/70°c) > only for HP S type. Ba-at: temperate water coil (45°/35°c) > only for HP S and HP lS.
Cooling for duct mounting: Ba-aF: cooling water coil with insulated plenum.
Air filtration: F9 optional filter low pressure loss.
MAIN ACCESSORIESAccessories control (for standard version only): cV4: 4 speed switch commutator for 230V-1-50Hz motors. cV3: 3 speed switch commutator for 230V-1-50Hz motors. rVt6a and rVt 9a speed regulator for 400V-3-50Hz motors.
Optional microprocessor controls (see the Accessories booklet): ctr08. ctr07. EVo PH. EVo d PH.
Optional sensors: EE80: co2 sensor. QPa 2002: co2/Voc air quality sensor. EE16: Humidity sensor.
Protective accessories: SKMF-r: weather protection cowl. t: weather protective roof.
Operating limit/recOmmendatiOns
new
66 67
hp s/hp l 1 2 3 4 5 6nominal airflow m³/h 400 800 1900 3000 4500 5600
available static pressure * Pa 85 100 140 180 100 120NOISE LEVEL ***
lw speed 1 (noise transmitted) dB(A) 29 42lw speed 2 (noise transmitted) dB(A) 37 48 65 52lw speed 3 (noise transmitted) dB(A) 43 53 67 68lw speed 4 (noise transmitted) dB(A) 48 55 69 79 75 77
DIMENSION**** AND WEIGHT FOR HORIzONTAL UNITS FOR HP S (COILS IN DUCT WITHOUT by-PASS ON CROSS PLATE)Height (without by-pass) mm 345 360 535 630 855 855
Height (with by-pass) mm 450 465 640 735 855 855Widht mm 640 820 1040 1270 1200 1200
lenght mm 960 1230 1560 1905 1550 1550Weight kg 40 56 110 155 195 200
circular spigots diameter inlet/outlet mm 200 250 315 355 450 450THERMAL RECOVERy UNIT **
Efficiency % 50.7 53.9 51.6 52.5 54 52.5
hp ls 400 800 1600 2500 3500nominal airflow m³/h 485 885 1600 2680 3500
available static pressure * Pa 100 100 100 100 100NOISE LEVEL FOR SINGLE SKIN ***
lw speed 1 (noise transmitted) dB(A) 33 45lw speed 2 (noise transmitted) dB(A) 41 52 57 59 57lw speed 3 (noise transmitted) dB(A) 47 57 59 61 65lw speed 4 (noise transmitted) dB(A) 52 59 61 63 71
DIMENSION AND WEIGHT FOR HORIzONTAL UNITSHeight (with ot without internal by-pass) mm 360 360 500 550 550
Widht mm 620 730 870 1040 1300lenght mm 960 - 1560 1905 1550Weight kg 55 56 110 155 195
circular spigots diameter inlet/outlet mm 200 250 315 355 450THERMAL RECOVERy UNIT **
Efficiency % 51.2 51.6 54.2 52.7 52.3
common dataFAN
Fan installed power W 150x2 355x2 373x2 550x2 750x2 750x2 1500x2Pole Nr. 2 2 4 4 4 4 4
Max current absorption A 0.66x2 1.55x2 2.75x2 4x2 8.1x2 3.1x2 5.6x2Max. current absorption A 1.32 3.1 5.5 8 16.2 6.2 11.2
Fan speed 4 4 3 3 3 1 1Protection level (iP)/insulation class IP20/F IP55/F
Electrical supply power V/ph/Hz 230V-1-50Hz 400V-3-50HzFILTER
Filtration class for exhaust/fresh air EN779 G4/F7ELECTRICAL HEATER OF DEICING
nominal power kW 2 4 6 8 8 12 12
Voltage/phase V/ph 230/1 230/1 230/1 230/1 or 400/3
230/1 or 400/3 400/3 400/3
For others characteristics, consult dedicated eDM or ontact the technical office.* Values reffering to the nominal airflow having overcome the loss of pressure of the recovery unit and filters.** Values referring to the following conditions: Tbs ext. air.=-5°C; Tbs environment=20°C; U.R. environment= 50%; Nominal airflow.*** Lw Sound power level taken in accordance to the UNI eN ISO 3747 (LfA ≥ 7 dB for each measurement position, class 2 accuracy).**** for bypass add 105mm in height up to size 4, 0mm for size 5 and 6
Horizontal configuration HPS/HPL Horizontal configuration HPLS Vertical configuration HPLS
or
or
or
or or
or
or
or or
68
Commercial Air Conditioning |
69
Premi@ir020 to 360air Handling unit
Water cooling capacity: from 10 to 175 kW Water Heating capacity: from 20 to 356 kW Sizes: 10 airflow range: from 1 000 to 30 000 m³/h insulation: glasswool, rockwool, Polyurethane Foam
DESCRIPTION With 10 models, from 1’000 to 30’000 m³/h, this range is adapted for comfort, hygienic & industrial applications. an innovative, robust self-supporting constitution with a perfectly smooth tunnel, including at the module junction points, thus avoiding any microbial growth due to dust build-up. the double skin panels are covered on all six sides to prevent any humidity penetration. they are equipped with fire retardant thermal insulation.
PRODUCT ADVANTAGES as the Premi@ir air handling units are made to measure, in strict compliance with the specific needs of each installation, they offer an infinite choice of solutions. Eurovent certified t2 - tB2 - l2 - F9 - d1, and, available on request, t3 - tB2 - l1 - F9 - d1, tuV tested (not Eurovent certified). Various combination available: in line, superposed or side by side. adapted for indoor or outdoor installation. access door without thermal bridge thanks to polyamide hinge and external rotor none crossing through the door. large choice of filter type and class, flat, bag and rigid from g4 to H14. large choice of coil available in standard from 2 rows up to 8 rows, with 2.1, 2.5 or 3.2mm fin spacing, with aluminium, aluminium Epoxy or copper fins, and/or, Blygold(r) coated for aggressive environment. a performant selection softawre with a user-friendly graphic interface allowing all types of simulations. For optimising offer presentations, it already provides «execution» quality documents (dXF format plans) at the quotation stage.
1500 Pa maximum on panel on negative and positive pressure. 40°c maximum on motor without undersizing factor on motor power. 60°c with undersizing factor of 0.82 on motor power. -20°c minimum for air intake. according to inner air temperature and outdoor air temperature, condensation can appear on panels.
MAIN OPTIONS 2 types of thermal wheel (std & high efficiency). 3 type of plates (std, medium & high efficiency). Extractable drain pan, or, 3-sloped dry drain pan for a perfect hygienic aspect. a choice of 3 types of dampers: Standard, airtight class 3 and airtight class 4 according En 1751.
2 mineral wool’s type available: glasswool or rockwool. large choice of metal finishing: galvanized, precoated, Stainless steel 304l (1.4307) or 316l (1.4404) on inner and/or outer skin. large choice of fans belt driven (forward and backward) or directly driven (plug-fan type), inspection hatch, bleed hole and epoxy paint on fan, variable speed pulley, dual speed motors, 60 Hz motors, standby motors, maintenance and repair switch...
MAIN ACCESSORIES M0 classified connection frame and flexible connectors. 24 V or 230 V interior lighting with sealed switch. inspection porthole on access door. air intake and air blowing rain hoods. roof. Fresh air louver. inlet bird screen. Sand louver. discharge plenum. Pressure tapping points. inclined or u shaped manometers. Empty sections with different lengths. rigid connection frame. actuators 3Pts/tor or 0-10V.
Operating limit/recOmmendatiOns
68 69
A type configuration D type configuration G type configuration J type configuration I type configuration
AR AEAN AS AS
AN
AC
AN
AS
AR
AEAS
AN
AR AC
AE
premi@ir - pr 20 40 60 90 120 160 200 240 300 360airflow (at 2.8 m/s on cooling coil) m³/h 1650 3300 5500 7500 9100 12850 16600 20200 24400 29450
Height with base frame (std or side by side) mm 685 1045 1045 1045 1225 1555 1555 1555 1845 2145Height with base frame (superposed) mm 1220 1940 1940 1940 2300 2960 2960 2960 3540 4140
Width (std or superposed) mm 715 715 1020 1325 1325 1325 1630 1935 1935 1935Width (side by side) mm 1430 1430 2040 2650 2650 2650 3260 3870 3870 3870
COILS
rows 1 to 8 en Heating - 2 to 8 in CoolingFin spacing for water coils mm 2.1 - 2.5 - 3.2
total cooling capacity (for 4rows - 2.5mm) kW 10.0 19.0 33.4 45.1 54.7 77.3 104.3 123.2 147.0 171.8Sensible cooling capacity (for 4rows - 2.5mm) kW 9.0 17.5 29.8 40.5 49.2 69.4 91.4 109.8 131.9 157.0
cooling coil connection (4rows) DN 25 25 32 32 32 50 50 65 65 65Heating capacity (for 2rows - 2.5mm) kW 19.9 40.3 66.9 92.0 110.6 155.4 201.7 246.9 296.9 355.6
Heating coil connection (2rows) DN 25 25 25 32 32 32 32 50 50 50Electric Heater capacity min kW 3.75 9.0 9.0 9.0 10.5 12.0 12.0 12.0 18.0 21.0Electric Heater capacity max kW 22.5 54.0 90.0 126.0 147.0 168.0 216.0 252.0 396.0 462.0
FAN
type available Forward - Backward - Reinforced backward - Plug fancentrifugal fan size min 160 200 250 280 355 400 450 500 560 630centrifugal fan size max 200 250 315 355 450 500 560 630 710 800
Plug fan fan size min 200 315 315 355 400 500 560 630 710 800Plug fan fan size max 250 400 400 450 500 630 710 800 900 1000
FILTER
Frame Classified F9 according to EN1886Filter available G2 (metal) & G4 flat - F5. F7 & F8 Bag - F7 & F9 Rigid - H10 to H14 HEPA
HEAT RECOVERy
run around coil From 2 up to 8 rowsthermal wheel std efficiency performance % 48 46 45 46 45 53 53 51 49 50
thermal wheel high efficiency performance % 60 59 59 59 58 59 59 57 58 61thermal plate std efficiency section length % 72 72 72 72 70 73 73 71 73 70
thermal plate medium efficiency performance % 68 34 56 70 59 50 54 50 55 50thermal plate high efficiency performance % 83 73 75 77 74 75 76 73 74 71
PR 20 40 60 90 120 160 200 240 300 360
Extraction (type a)Backward Fan alone
length 820 920 1120 1220 1520 1520 1620 1720 1820 2020
Weight 99 136 189 226 315 371 442 539 723 891
100% fresh air (type d)g4 Flat/F7 bag filters + heating coil 2r
+ cooling coil 4r + backward fan
length 2120 2220 2420 2520 2620 2940 3040 3240 3240 3340
Weight 261 342 454 525 610 805 949 1184 1321 1647
2-way Mixing air (type g)2-ways mixing section + type d
length 2420 2620 2940 3040 3240 3540 3640 3840 3840 4140
Weight 293 385 524 598 709 902 1059 1305 1464 1843
double flux in line (type J)type a + 3-Ways mixing in line + type d
length 3660 4060 4460 4660 5060 5780 5980 6280 6380 7080
Weight 427 563 749 848 1021 1334 1560 1912 2247 2839
Superposed (type i)type g on fresh air
type a + flat g4 filter on Exhaust air
length 3440 3840 4060 4160 4560 4860 5160 5480 5680 6280
Weight 538 692 944 1057 1265 1568 1971 2374 2782 3419
Cooling coil performance for 32°C/40% - 7-12°C & Heating coil performance for -7°C/90% - 90/70°C.
70
Commercial Air Conditioning |
71
@irTwin020 to 360air Handling unit
Water cooling capacity: from 10 to 175 kW Water Heating capacity: from 20 to 356 kW Sizes: 10 airflow range: from 1 000 to 30 000 m³/h insulation: 25 mm glasswool and rockwool
DESCRIPTION With 10 models, from 1 000 to 30 000 m³/h, this range is adapted for comfort & industrial applications. Public buildings compatible framework with aluminium profile, and, rigid and light corners made of polycarbonate reinforced by glass fibers. the double skin panels, 25 mm thick, are covered on all six sides to prevent any humidity penetration. they are equipped with fire retardant thermal insulation.
PRODUCT ADVANTAGES as the Premi@ir air handling units are made to measure, in strict compliance with the specific needs of each installation, they offer an infinite choice of solutions. Eurovent certified t4 - tB3 - l2 - F9 - d1. Various combination available: in line, superposed or side by side. adapted for indoor or outdoor installation (caution on panel’s condensation risk). large choice of filter type and class, flat, bag and rigid from g4 to F9. large choice of coil available in standard from 2 rows up to 8 rows, with 2.1, 2.5 or 3.2 mm fin spacing, with aluminium, aluminium Epoxy or copper fins, and/or, Blygold(r) coated for aggressive environment. a performant selection software with a user-friendly graphic interface allowing all types of simulations. For optimising offer presentations, it already provides «execution» quality documents (dXF format plans) at the quotation stage.
1000 Pa maximum on panel on negative and positive pressure. 40°c maximum on motor without undersizing factor on motor power. 60°c with undersizing factor of 0.82 on motor power. -20°c minimum for air intake for internal components. according to inner air temperature and outdoor air temperature, condensation can appear on panels and/or profile.
MAIN OPTIONS 2 types of thermal wheel (std & high efficiency). 3 type of plates (std, medium & high efficiency). a choice of 3 types of dampers: Standard, airtight class 3 and airtight class 4 according En 1751.
2 mineral wool’s type available: glasswool or rockwool. large choice of metal finishing: galvanized, precoated, Stainless steel 304l (1.4307) or 316l (1.4404). large choice of fans belt driven (forward and backward) or directly driven (plug-fan type), inspection hatch, bleed hole and epoxy paint on fan, variable speed pulley, dual speed motors, 60 Hz motors, standby motors, maintenance and repair switch…
MAIN ACCESSORIES M0 classified connection frame and flexible connectors. 24 V or 230 V interior lighting with sealed switch. inspection porthole on access door. air intake and air blowing rain hoods. roof. Fresh air louver. inlet bird screen. Sand louver. discharge plenum. Pressure tapping points. inclined or u shaped manometers. Empty sections with different lengths.
Operating limit/recOmmendatiOns
70 71
@irtwin - tr 20 40 60 90 120 160 200 240 300 360airflow (at 2.8 m/s on cooling coil) m³/h 1650 3300 5500 7500 9100 12850 16600 20200 24400 29450
Height with base frame (std or side by side) mm 685 1045 1045 1045 1225 1555 1555 1555 1845 2145Height with base frame (superposed) mm 1220 1940 1940 1940 2300 2960 2960 2960 3540 4140
Width (std or superposed) mm 715 715 1020 1325 1325 1325 1630 1935 1935 1935Width (side by side) mm 1430 1430 2040 2650 2650 2650 3260 3870 3870 3870
COILS
rows 1 to 8 en Heating - 2 to 8 in CoolingFin spacing for water coils mm 2.1 - 2.5 - 3.2
total cooling capacity (for 4rows - 2.5mm) kW 10 19 33.4 45.1 54.7 77.3 104.3 123.2 147 171.8Sensible cooling capacity (for 4rows - 2.5mm) kW 9 17.5 29.8 40.5 49.2 69.4 91.4 109.8 131.9 157
cooling coil connection (4rows) DN 25 25 32 32 32 50 50 65 65 65Heating capacity (for 2rows - 2.5mm) kW 19.9 40.3 66.9 92 110.6 155.4 201.7 246.9 296.9 355.6
Heating coil connection (2rows) DN 25 25 25 32 32 32 32 50 50 50Electric Heater capacity min kW 3.75 9 9 9 10.5 12 12 12 18 21Electric Heater capacity max kW 22.5 54 90 126 147 168 216 252 396 462
FAN
type available Forward - Backward - Reinforced backward - Plug fancentrifugal fan size min 160 200 250 280 355 400 450 500 560 630centrifugal fan size max 200 250 315 355 450 500 560 630 710 800
Plug fan fan size min 200 315 315 355 400 500 560 630 710 800Plug fan fan size max 250 400 400 450 500 630 710 800 900 1000
FILTER
Frame Classified F9 according to EN1886Filter available G2 (metal) & G4 flat - F5. F7 & F8 Bag - F7 & F9 Rigid - H10 to H14 HEPA
HEAT RECOVERy
run around coil From 2 up to 8 rowsthermal wheel std efficiency performance % 48 46 45 46 45 53 53 51 49 50
thermal wheel high efficiency performance % 60 59 59 59 58 59 59 57 58 61thermal plate std efficiency section length % 72 72 72 72 70 73 73 71 73 70
thermal plate medium efficiency performance % 68 34 56 70 59 50 54 50 55 50thermal plate high efficiency performance % 83 73 75 77 74 75 76 73 74 71
PR 20 40 60 90 120 160 200 240 300 360
Extraction (type a)Backward Fan alone
length 784 884 1084 1184 1484 1484 1584 1684 1784 1984
Weight 99 136 189 226 315 371 442 539 723 891
100% fresh air (type d)g4 Flat/F7 bag filters + heating coil 2r
+ cooling coil 4r + backward fan
length 2084 2184 2384 2484 2584 2868 2968 3168 3168 3268
Weight 261 342 454 525 610 805 949 1184 1321 1647
2-way Mixing air (type g)2-ways mixing section + type d
length 2384 2584 2868 2968 3168 3468 3568 3768 3768 4068
Weight 293 385 524 598 709 902 1059 1305 1464 1843
double flux in line (type J)type a + 3-Ways mixing in line + type d
length 3552 3952 4352 4552 4952 5636 5836 6136 6236 6936
Weight 427 563 749 848 1021 1334 1560 1912 2247 2839
Superposed (type i)type g on fresh air
type a + flat g4 filter on Exhaust air
length 3368 3768 3952 4052 4452 4752 5052 5336 5536 6136
Weight 538 692 944 1057 1265 1568 1971 2374 2782 3419
Cooling coil performance for 32°C/40% - 7-12°C & Heating coil performance for -7°C/90% - 90/70°C.Heat recovery performances given for balanced airflow - fresh air -7°C/90% - Return air 22°C/50% - Plate without by-pass - thermal wheel with minimum fin spacing possible
A type configuration D type configuration G type configuration J type configuration I type configuration
AR AEAN AS AS
AN
AC
AN
AS
AR
AEAS
AN
AR AC
AE
72
Commercial Air Conditioning |
73
@irTwin400 à 1000air Handling unit
Water cooling capacity: from 200 to 505 kW Water Heating capacity: from 500 to 1375 kW Sizes: 5 airflow range: from 30’000 to 100’000 m³/h insulation: 50mm glasswool or rockwool
DESCRIPTION With 5 additional models, from 30’000 to 100’000 m³/h, @irtwin range is adapted for comfort, hygienic & industrial applications, in line with the mains features proposed on Premi@ir range. Public buildings compatible framework with aluminium profile, and, rigid and light corners made of polycarbonate reinforced by glass fibers,. the double skin panels, 50mm thick with fire retardant thermal insulation, are covered on all six sides to prevent any humidity penetration.
PRODUCT ADVANTAGES as for Premi@ir air handling unit, @irtwin 400 to 1000 are made to offer a product in compliance with the specifics needs of each installation by offering an infinite choice of solution.
Eurovent certified t4 - tB3 - l2 - F9 - d1. Various combination available: in line, superposed or side by side. adapted for indoor or outdoor installation. access door without thermal bridge thanks to polyamide hinge and external rotor none crossing through the door. large choice of filter type and class, flat, bag and rigid from g4 to H14. large choice of coil available in standard from 2 rows up to 8 rows, with 2.0 or 3.0mm fin spacing, with aluminium, aluminium Epoxy or copper fins, and/or, Blygold(r) coated for aggressive environment. a performant selection software with a user-friendly graphic interface allowing all types of simulations. For optimising offer presentations, it already provides «execution» quality documents (dXF format plans) at the quotation stage.
1500 Pa maximum on panel on negative and positive pressure. 40°c maximum on motor without undersizing factor on motor power. 60°c with undersizing factor of 0.82 on motor power. -20°c minimum for air intake. according to inner air temperature and outdoor air temperature, condensation can appear on panels.
MAIN OPTIONS 2 types of thermal wheel (std & high efficiency) 3 type of plates (std, medium & high efficiency) a choice of 3 types of dampers: Standard, airtight class 3 and airtight class 4 according En 1751
2 mineral wool’s type available: glasswool or rockwool large choice of metal finishing: galvanized, precoated, Stainless steel 304l (1.4307) or 316l (1.4404) large choice of fans belt driven (forward and backward) or directly driven (plug-fan type), inspection hatch, bleed hole and epoxy paint on fan, variable speed pulley, dual speed motors, 60 Hz motors, standby motors, maintenance and repair switch…
MAIN ACCESSORIES M0 classified connection frame and flexible connectors. 24 V or 230 V interior lighting with sealed switch. inspection porthole on access door. air intake and air blowing rain hoods. roof. Fresh air louver. inlet bird screen. Sand louver. discharge plenum. Pressure tapping points. inclined or u shaped manometers. Empty sections with different lengths.
Operating limit/recOmmendatiOns
72 73
@irtwin - tr 400 500 700 900 1000airflow (at 2.8 m/s on cooling coil) m³/h 34290 42200 53200 70930 87865
Height with base frame (std or side by side) mm 2230 2230 2230 2850 2850Height with base frame (superposed) mm 4280 4280 4280 N/A N/A
Width (std or superposed) mm 2220 2670 3300 3300 4000Width (side by side) mm 4440 5340 6600 6600 8000
COILS
rows 2 to 8Fin spacing for water coils mm 2.0 & 3.0
total cooling capacity (for 4rows - 3.0mm) kW 199,3 257,9 301,6 415,9 505,3Sensible cooling capacity (for 4rows - 3.0mm) kW 184,4 231,8 273,7 382,7 470,4
cooling coil connection (4rows) DN 65 65 80 80 80Heating capacity (for 2rows - 2.0mm) kW 538,0 671,0 819,0 1092,0 1375,0
Heating coil connection (2rows) DN 50 65 65 65 80Electric Heater capacity min kW 21,0 21,0 21,0 24,0 24,0Electric Heater capacity max kW 252,0 420,0 588,0 624,0 840,0
FAN
type avaialbe Forward - Backward - Renforceid backward - Plugfancentrifugal fan size min 630 710 800 900 1000centrifugal fan size max 800 900 900 1000 -
Plugfan fan size min 900 900 900 1120 1120Plugfan fan size max 1120 1120 1120 1400 1400
FILTER
Frame Classified F9 according to EN1886Filter available G2 (metal) & G4 flat - F5, F7 & F8 Bag - F7 & F9 Rigid - H10 to H14 HEPA
HEAT RECOVERy
run arround coil from 2 up to 8 rowsthermal wheel std efficiency perfomance % 50 46 46 N/A N/A
thermal wheel high efficiency perfomance % 55 50 50 N/A N/Athermal plate std efficiency section leng % 62 56 56 N/A N/A
thermal plate medium efficiency perfomance % 54 59 56 N/A N/Athermal plate high efficiency perfomance % 70 N/A N/A N/A N/A
Cooling coil performance for 32°C/40% - 7-12°C & Heating coil performance for -7°C/90% - 90/70°C.N/A: Not available.Heat recovery performances given for balanced airflow - fresh air -7°C/90% - Return air 22°C/50% - Plate without by-pass - thermal wheel with minimum fin spacing possible
A type configuration D type configuration G type configuration J type configuration I type configuration
AR AEAN AS AS
AN
AC
AN
AS
AR
AEAS
AN
AR AC
AE
74
Commercial Air Conditioning |
75
ARAS
984 884 2284
415240
971x
1077
AR
AE AN
AS
150
40
130
1077
x971
4152
984 884 2284
DXF plan generateD by WinClim ii
WinClim II, seleCtIon softWare for PreMI@Ir & @IrtWIn
Selecting Premi@ir with Autocad compa-tible software benefiting from Eurovent certification, Premi@ir air handling units can be selected with the aid of Eurovent approved software.
This software has a user-friendly graphic inter-face and runs under all versions of Windows operating systems (98 SE, XP, NT, 2000, Se-ven). With the WinCLim II selection software, all types of simulations are possible. For opti-mising offer presentations, il already provides “execution” quality documents (DXF format plans) at the quotation stage. WinClim II also ensures that the quotations are stored in me-mory for future reference and for personalising offers.
WinClim II and Premi@ir, are the garantee of having full details of all your choices, where nothing is left to chance.Choice such as fan performance curves with operating point visualisation, air changes on the Psychrometric diagram. Already, at the quotation stage, you receive an execution quality dossier.
74 75
eCLIM SELECTION SOFTWARE FOR SLIM@IR
The eCLIM selection software is a selection tool with 3D view allowing users to select the Slim@ir AHU compact air handling units.
Intuitive, user-friendly, fast and efficient, eCLIM allows the users: To select and visualize a unit, To represent a unit as scaled 3D model, To change and configure components, To automatically generate 2D/3D drawings in DXF format, selection sheets including the complete technical data and prices, as well as a manufacturing entry form.
eCLIM uses a high-performance visual interface, indeed the user can see exactly what he does and the modifications carried out are taken instantaneously into account in the visualized model.
The innovative procedure of eCLIM selection software allows even the operators less experienced to select, design and establish prices of complicated air handling units.
The user can add, modify, move or delete components by a simple click of mouse.
76
Commercial Air Conditioning |
77
HAN rooFtoP unit - cooling and HEating
cooling capacity: from 9.8 to 31 kW Heating capacity: from 9.6 to 30.5 kW refrigerant: r410a Sizes: 7
CONFIGURATIONS: compact monobloc system
PRODUCT ADVANTAGES Weather resistant casing with external panels and drain pan coated with powder-based epoxy paint colour ral 9001. Base rail with forklift slots to facilitate transportation and handling. technical compartment independent from airstreams allowing service works to be performed without disturbing the unit operation.
High EEr and environmentally freindly refrigerant r410a with zero odP (ozone depleting Potentila). High efficiency scroll compressor with crankcase heater. condenser coils with hydrophilic coated fins to improve removal of water droplets during defrost cycles. Standard microprocessor-based control by cac controller.
MAIN OPTIONS Factory-fitted low ambient temperature control to ensure cooling operation down to -10°c outdoor temperature (all-season).
MAIN ACCESSORIES Synthetic air filter. Electric heater. Programmable controlller rcW2 to control up to 15 units with independent set points and programming.
Operating limit fOr Standard unitCOOLING MODE
Minimum indoor air temperature 21°C DB/15°C WB
Maximum indoor air temperature 32°C DB/23°C WB
Minimum outdoor air temperature/with all-season kit 15°C DB/-10°C
Maximum outdoor air temperature 50°C DB
HEATING MODE
Maximum indoor air temperature 27°C DB
Minimum outdoor air temperature -10°C
Maximum outdoor air temperature 24°C (16°C for HAN 25)
R410A
76 77
han sise han 10 han 13 han 15 han 17 han 19 han 25 han 31CAPACITIES
coolingcooling capacity kW 9.8 13.0 14.5 16.8 18.9 25.4 31.0
Power input kW 3.7 4.5 4.9 6.0 6.5 8.3 10.0EEr 2.64 2.88 2.95 2.8 2.9 2.95 3.1
HeatingHeating capacity kW 9.6 12.1 14.2 15.8 19.0 24.2 30.5
Power input kW 3.0 4.3 4.5 5.7 6.0 8.8 9.5coP 3.2 2.8 3.1 2.7 3.1 2.75 3.2
COMPRESSOR
type Scroll Scroll Scroll Scroll Scroll Scroll Scrollnumber 1 1 1 1 1 1 1
VENTILATION
available static pressure Pa 90 100 170 160 210 240 250
airflowindoor fan m³/h 1930 2640 2940 3190 3860 4780 5530
outdoor fan m³/h 5200 9000 9000 9000 9000 12000 12000SOUND LEVELS *
lw outdoor - configuration a dB(A) 79.7 80.7 79.3 79.3 83.1 84.9 86.4Sound pressure lp calculated at 1 m dB(A) 75.9 76.9 75.5 75.5 79.3 81.1 82.6Sound pressure lp calculated at 5 m dB(A) 73.8 74.8 73.4 73.4 77.2 79.0 80.5
lw indoor - configuration B dB(A) 76.1 77.1 75.0 75.0 72.7 78.2 82.7Sound pressure lp calculated at 1 m dB(A) 72.3 73.3 71.2 71.2 68.9 74.4 78.9Sound pressure lp calculated at 5 m dB(A) 70.2 71.2 69.1 69.1 66.8 72.3 76.8
POWER SUPPLy
Power supply 400V/3P/50 HzFuse rating am A 16 16 20 20 25 32 32
DIMENSIONS (LxWxH)
mm 1115x1150x750 1320x1345x905 1320x1345x905 1320x1345x905 1320x1345x905 1420x1445x1320 1420x1445x1320WEIGHT
unit weight kg 165 219 223 223 243 320 343
PRODUCT CODE
Standard Code 7Hl023001 7Hl023002 7Hl023003 7Hl023004 7Hl023005 7Hl023006 7Hl023007With all season control Code 7Hl023008 7Hl023009 7Hl023010 7Hl023011 7Hl023012 7Hl023013 7Hl023014
ACCESSORIES
air filter Code 7ACVF0145 7ACVF0481 7ACVF0481 7ACVF0481 7ACVF0481 7ACVF0482 7ACVF0482
Electric heaterkW 6 9 9 12 12 12 12Code 7ACEl1216 7ACEl1217 7ACEl1217 7ACEl1219 7ACEl1219 7ACEl1219 7ACEl1219
remote control rcW2 Code 7ACEl1212 7ACEl1212 7ACEl1212 7ACEl1212 7ACEl1212 7ACEl1212 7ACEl1212
* Pressure sound level calculated according the following:
Lp = Lw + 10 Log ( Q 4_____ + ___ )4πD² A
Factor Q 2 2 = free field, 4 = against wall, 8 = on cornerV 100 Room volume in m³ (on example, V = 100 m3) lg = 10t 1 Reverberation time in s lg = 10a 16 A = 0.16 x (V/T) Ht = 2.5d Distance in m
78
Commercial Air Conditioning |
79
RoofT@irRTL/RTH 40 to 110 rooFtoP unit - cooling and HEating
cooling capacity: from 41 to 108 kW Heating capacity: from 43 to 108 kW refrigerant: r410a airflow range: from 7 650 to 20 000 m³/h Sizes: 7 insulation: 25mm glasswool
Operating limit fOr Standard unitCOOLING MODE
Maximum outdoor air temperature 46°C
Minimum outdoor air temperature (6) 20°C
HEATING MODE
Maximum outdoor air temperature 21°C
Minimum outdoor air temperature -10°C
DESCRIPTION compact, light and single piece design with all panels, floor and roof exposed to weather, painted inside and outside to prevent corrosion, and, fully insulated cabinet to offer the best thermal and acoustical protection. rooft@ir is an assembled weatherproof single package, using r410a refrigerant to improve EEr, cooling only or heat pump with additional heating (optional) by electric heaters or hot water coil.
Manufactured in factory certificated iSo 9001:2008, rooft@ir is compliant to PEd-97-23 and En-60204-1, pre-assembled in one single package fully tested at the factory, and, designed for outdoor use and roof curb application.
PRODUCT ADVANTAGESTechnical compartments for RTL/RTH 100-110 Weatherproof technical compartment independent from the airflow with a natural ventilation of the electrical board to stop overheating in summer. all electric cables and wires are protected.
Refrigeration system: r410a benefitsBest heat transfer and environmental friendly refrigerant with zero odP (ozone depleting Potential). Stable composition compared to r407c (2 refrigerant mixture instead of 3 with r407c).temperature glide less than 0.2 K during evaporation, smaller liquid line pipe and lower refrigerant charge. refrigeration circuitcooling only or heat pump version designed to satisfy comfort and commercial applications with scroll compressors for higher efficiency with better resistance to liquid return and less vibration. crankcase heater on each compressor to eliminate refrigerant migration and improve start up in winter.tandem compressors on 1-circuit and single compressor on dualcircuits provide 2-stage cooling/heating capacity. refrigerant brazing, fittings, and indoor coil headers are assembled in one technical compartment to ease service without disturbing unit operation.
MAIN OPTIONSFilters: universal cells’ dimensions mounted on sliding rail for easy service. 2 options of flat filters: g4 filter & High efficiency filter g4+ F6 compliant with En 779. Factory fitted clogged filter switch wired to the iatc (option).
2-damper economizer (R1 and R2 configurations): Economizer allows using the greatest obtainable quantity of outdoor air energy to minimize compressor consumption. Economizer is equipped with 2 counteracting dampers linked together to one proportional actuator wired to iatc. adjustable minimum position of outdoor air damper to control hygienic ventilation. the economizer is equipped with sensors wired to the iatc. according to control type, 3 combinations of sensors are available: Sensible, Enthalpy, or, air quality control.
Additional options: Standard or ErP conform roof curb. antivibration mounts. Smoke detector. double skin.
MAIN ACCESSORIES Bi-flow devices (expansion device, filter-dryer, sight glass) are used on each circuit. outdoor coils designed for low air resistance to reduce axial fan power consumption and noise level.
Hydrophilic blue fins provided on outdoor coils (heat pump version only) for better removal of water droplets on defrost cycle. Holes in the unit floor under the outdoor coils to drain defrost and rain water beyond the roof curb to the roof. indoor coil (blue fins) allows for commercial or industrial applications with higher dehumidification rate.
Extractible drain pan under indoor coil, to allow for hygienic cleaning. optional low ambient operation kit ensures cooling operation down to -10 °c outdoor temperature. optional electric heater cH1 & cH2, and, hot water coil.
R410A
78 79
cooling only versionrtl models rtl 40 rtl 50 rtl 60 rtl 70 rtl 80 rtl 100 rtl 110
cooling capacity (1) kW 41.5 50.9 59.8 67.7 84.9 96.6 108.4Power input kW 12.8 16 18.4 20.9 26 30.9 36.5
EEr (2) 3.3 3.2 3.3 3.2 3.3 3.1 3Power supply 400V - 3ph + N - 50Hz
heat pump versionrth models rth 40 rth 50 rth 60 rth 70 rth 80 rth 100 rth 110
cooling capacity (1) kW 41 48.6 59 66 83.4 94.8 106.1Power input kW 12.8 16 18.4 20.9 26 30.9 36.5
EEr - cooling mode (2) 3.2 3 3.2 3.2 3.2 3.1 2.9Heating capacity (3) kW 42.9 50.2 58.2 66.5 84 96 108
Power input kW 12.2 15.1 17.8 20.3 24.1 28.5 33.7coP - Heating mode (4) 3.5 3.3 3.3 3.3 3.5 3.4 3.2
Power supply 400V - 3ph + N - 50Hz
common data - range rtl/rthREFRIGERANT
type R410A number of circuits 1 1 2 2 2 2 2
COMPRESSORSnumber of compressors 2 2 2 2 2 2 2
assembly type Tandem Tandem Single Single Single Single Singlecapacity step % 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100
INDOOR COILtype Copper tubes & aluminium fins
number of rows 3 3 3 3 3 4 4coil face area m2 1.6 1.6 2 2.1 2.3 2.3 2.3
INDOOR FANtype (standard) Forward curved centrifugalQuantity/Model 1/AT 15-15S 1/AT 15-15S 1/ADH 450 1/ADH 450 1/ADH 500 1/ADH 500 1/ADH 500
air flow m³/h 7 650 9 200 11 500 12 500 16 500 18 650 20 000nominal static pressure Pa 250 250 300 300 350 350 350
Motor power kW 1.5 2.5 5.5 5.5 7.5 7.5 7.5type (optional) Forward curved centrifugal Backward curved centrifugal
Quantity/Model 1/AT 15-15S 1/AT 15-15S 1/RDH 450 1/RDH 450 1/RDH 500 1/RDH 500 1/RDH 500air flow m³/h 7 650 9 200 11 500 12 500 16 500 18 650 20 000
nominal static pressure Pa 400 400 450 450 500 500 500Motor power kW 4 5.5 5.5 5.5 7.5 7.5 7.5
OUTDOOR COILtype Copper tubes & aluminium fins
number of rows 2 2 2 2 2 2 2coil face area m2 3 3 4 4 4.3 6.1 6.1
OUTDOOR FANStype Propeller
diameter mm 610 610 610 610 610 800 800Quantity 2 2 4 4 4 2 2
Fan rotational speed rpm 850 850 850 850 850 670 670nominal air flow m³/h 16000 16000 32000 32000 32000 34000 34000
total motor power kW 1.14 1.14 2.28 2.28 2.28 2 2SyNTHETIC FLAT FILTERS (OPTIONAL)
number of filters 4 4 9 9 9 9 9Efficiency/Filter class > 90%/G4
type Universal cellsSyNTHETIC FLAT FILTERS (OPTIONAL)
number of filters 4 4 9 9 9 9 9Efficiency/Filter class > 90%/F6
type Universal cellsCASING
Min. casing thickness mm 1 1 1 1 1 1 1Painting type/RAl Powder coating/9001
Fire resistance class M0 DIMENSIONS & WEIGHT
length mm 2484 2484 3400 3400 3400 3400 3400Width mm 1877 1877 2227 2227 2227 2227 2227
Height mm 1450 1450 1771 1771 1771 1813 1813Foot print m2 4.66 4.66 7.57 7.57 7.57 7.57 7.57Weight (5) kg 650 700 1100 1150 1200 1300 1350
ELECTRICAL DATA (7)
rtl/rth models 40 50 60 70 80 100 110PE GE PE GE PE GE PE GE PE GE PE GE PE GE
Supply voltage 400V - 3 Ph + N/50 Hztotal runing current A 46 51 57 63 69 69 73 73 94 94 100 100 109 109
Maximum starting current A 132 137 193 199 178 178 213 213 261 261 275 275 284 284Fuse rating aM A 50 63 63 63 80 80 80 80 100 100 100 100 125 125
Pe: Standard ventilation. Ge: High static presssure ventilation.(1) Cooling capacity with eurovent conditions: 35 °C dry bulb outdoor, 27 °C dry bulb/19 °C wet bulb entering indoor. (2) eeR = Cooling capacity/effective power input. (3) Heating capacity with eurovent conditions: 7 °C dry bulb/6 °C wet bulb outdoor, 20 °C entering indoor. (4) COP = Heating capacity/Power input. (5) Without option. (6) For lower outdoor air temperature (-10 °C), in cooling mode, use low ambient kit (optional). (7) Unit without electric heater.
80
Commercial Air Conditioning |
81
RoofTechRTCL 100 to 160/RTCH 100 to 220 rooFtoP unit - cooling and HEating
cooling capacity: from 101 to 221 kW Heating capacity: from 97 to 220 kW refrigerant: r410a airflow range: from 20 000 to 30 000 m³/h (40 000 m³/h with rtcH)
Sizes: 4 (coolong only) - 7 (heat pump) insulation: 50 mm glasswool
Operating limit fOr Standard unitCOOLING MODE
Maximum outdoor air temperature 46°C
Minimum outdoor air temperature (6) 20°C
HEATING MODE
Maximum outdoor air temperature 21°C
Minimum outdoor air temperature -7°C
DESCRIPTION Pre-assembled weatherproof single package, designed to save energy and for long life durability thanks to an efficient double wall aluminium casing, less weight and prevent insulation fibber from entering the building and from harmful build-up of bacteria or contaminants.
PRODUCT ADVANTAGES inspired by Premi@ir air Handling unit, all the internal features on air side are designed to fulfill the requierments and the quality requiered on air Handling unit thanks to double-skin panels 50mm thick, a filter frame F9 conform regarding En1886, or, hinged doors composed of none-corrosive polyamide hinges and external progressive rotors without thermal bridge as used on Premi@ir and @irtwin 400 to 1000.
rooftech is also develloped to facilitate the maintenance operation thanks to two technical compartments:- Main weatherproof technical compartment with left and right
hinged service doors, double floor with 50 mm insulation to reduce noise disturbance to buildingand, and, walk-in service to compressors, electrical and control devices with no interference to unit operation (tc1). control and electrical board with a distinctive sliding door to shield from wind-and rain disturbances with natural ventilation of the electrical board to stop overheating in summer.
- indoor technical compartment (tc2) divided from the air flow with access door giving an access to sight-glass and expansion device with no interference to unit operation.
an other advatage of rooftech range is his efficient pre-mixing gas burner to hold air-gas mixture-ratio constant (13/1) throughout the complete heat capacity-modulation or -staging with a variable speed combustion air blower (600 to 1500 rpm) ensures modulation between 30 and 100% of maximal heating capacity ensuring an optimal pre-mixture of gas/oxygen at the required capacity.
MAIN OPTIONS Factory-fitted protective grilles for air entering fin surfaces of outdoorcoils. Factory-fitted low-ambient control to ensure cooling operation down to +10 °c outdoor temperature (rtcl only). High efficiency filter assembly g4+ F7 bag filters compliant with En 779. Factory fitted clogged filter switch wired to the iatc. Smoke detector downstream the filters. Factory fitted economizer with 2 dampers* and one supply blower. Enthalpy control taking the moisture of the outdoor air in consideration to reference entalpy setting. air quality control (Voc: Volatile organic compound) (optional and placed at return side) to trace high population density in the building and provides sufficient ventilation. droplets eliminator on fresh air (optional). optional exhaust air blower kit to be used in association with the 2 damper economizer, with r1 return only. Manual 0-25% fresh air kit. Factory fitted economizer with 3 dampers and with return fan. Heat recovery system by run around coils with glycol. Hot water, Electric, or, gas heat.
MAIN ACCESSORIES Electronic expansion valve (EEV) on heat pump model. 2-dampers and 3-dampers economizer with Weather hood integrated. Electric heater cH1 & cH2. Heat recovery run around coils. Manual 0-25% fresh air kit with Weather hood integrated. droplet eliminator for manual fresh air kit or for 2-damper economizer. condenser protective grilles. Standard or ErP roof curb.
ROOFTECH MODELS100 to 160 180 to 220
Burner type Modulating gas burner with condensationgas G20 (G25 & G30 upon request)
Supply pressure mbar Min: 17 - Max: 25Minimum capacity kW 42.4 55.7gas consumption m³/h 4.66 5.61
Maximum efficiency % 103.5 105.1Maximum capacity kW 156.3 197
gas consumption m³/h 16.4 22.75Maximum efficiency % 93 91.6
condensation produced l/h 3.87 4.9Ø gas connection inches UNI ISO 7/1 - 1"M
Ø condensation drain mm 20cE approval 0694 BM 3433
R410A
80 81
cooling only version
rtcl models 100 120 140 160 180 200 220cooling capacity (1) kW 101 115.2 135.4 158.1 N/A N/A N/A
Power input kW 34.9 40.9 46.8 54.2 N/A N/A N/AEEr (2) 2.89 2.82 2.89 2.92 N/A N/A N/A
heat pump version
rtch model 100 120 140 160 180 200 220cooling capacity (1) kW 98.5 112.4 132.1 154.2 176.4 198.8 221.1
Power input kW 34.9 40.9 46.8 54.2 61.9 68.4 74.8EEr (2) 2.83 2.75 2.82 2.84 2.85 2.91 2.96
Heating capacity (3) kW 97.4 114.6 134.7 155.3 175.2 197.5 220.0Power input kW 31.9 37.2 44.4 51.5 59.3 66.2 73.1
coP (4) 3.06 3.08 3.03 3.01 2.95 2.98 3.01
common data - range rtcl/rtchREFRIGERANT
type R410A R410A R410A R410A R410A R410A R410Anumber of circuit 2 2 2 2 2 2 2
COMPRESSORnumber of compressor 4 4 4 4 4 4 4
assembly type Tandem Tandem Tandem Tandem Tandem Tandem Tandemcompressor type Scroll Scroll Scroll Scroll Scroll Scroll Scrollcapacity control % 100-75-50-25-0
INDOOR COILtube type Copper 3/8" and aluminium fins
number of row 3 3 3 3 4 4 4airflow area m² 3.24 3.24 3.24 3.24 3.24 3.24 3.24
SUPPLy FANtype Centrifugal
number 1 1 1 1 1 1 1nominal air flow m³/h 20000 22500 27500 30000 34000 37000 40000
Standard fan ADH 500 ADH 560 ADH 560 ADH 560 ADH710 ADH710 ADH710nominal external static pressure Pa 250 350 350 350 350 350 350
Motor power kW 7.5 7.5 11.0 11.0 11.0 11.0 11.0High pressure fan (optional) RDH 500 RDH 560 RDH 560 RDH 560 RDH710 RDH710 RDH710
nominal external static pressure Pa 500 550 550 550 550 600 600Motor power kW 7.5 7.5 11.0 11.0 11.0 15.0 15.0
RETURN FAN (3-DAMPER SySTEM ONLy)type Centrifugal
number 1 1 1 1 1 1 1nominal air flow m³/h 20000 22500 27500 30000 34000 37000 40000
Standard fan ADH 500 ADH 560 ADH 560 ADH 560 ADH710 ADH710 ADH710nominal external static pressure Pa 100 100 100 100 300 300 300
Motor power kW 7.5 7.5 11.0 11.0 11.0 11.0 11.0OUTDOOR COIL
coil type Copper 3/8" and treated aluminium finsnumber of row 2 2 2 2 3 3 3
airflow area m² 3.78 3.78 4.14 4.14 4.14 4.14 4.14OUTDOOR FAN
type Propellerdiameter mm 800 800 800 800 910 910 910Quantity 2 2 2 2 2 2 2
Fan rPM tr/mn 820 820 895 895 850 850 850nominal outdoor airflow m³/h 19000 19000 20500 20500 28000 28000 28000
Motor power (total) kW 2 x 1.85 2 x 1.85 2 x 1.85 2 x 1.85 2 x 3.5 2 x 3.5 2 x 3.5SyNTHETIC FLAT FILTERS (OPTIONAL)
number of filters 9 9 9 9 9 9 9Efficiency/Filter class > 90%/G4
bAG FILTERS (OPTIONAL)number of filters 9 9 9 9 9 9 9
Efficiency/Filter class < 90%/F7DIMENSIONS & WEIGHT (5)
length (without fresh hood) mm 4743 4743 4743 4743 5444 5444 5444Width mm 2209 2209 2209 2209 2209 2209 2209
Height mm 2229 2229 2229 2229 2229 2229 2229Foot print m² 10.46 10.46 10.46 10.46 12.03 12.03 12.03
Weight kg 1720 1740 1760 1780 2080 2190 2270
ELECTRICAL DATA (7)
rooftech models 100 120 140 160 180 200 220PE GE PE GE PE GE PE GE PE GE PE GE PE GE
Supply voltage 400 V/3 Ph/50 Hz + Neutraltotal running current A 124 124 128 128 152 152 153 153 178 178 198 205 218 225
Maximum starting current A 214 214 236 236 245 245 286 286 345 345 383 390 393 400unit aM fuses A 160 160 160 160 160 160 160 160 200 200 250 250 250 250
Pe: Standard ventilation. Ge: High static presssure ventilation.(1) Cooling capacity with eurovent conditions: 35 °C dry bulb outdoor, 27 °C dry bulb/19 °C wet bulb entering indoor. (2) eeR = Cooling capacity/Unit power input. (3) Heating capacity with eurovent conditions: 7 °C dry bulb/6 °C wet bulb outdoor, 20 °C entering indoor. (4) COP = Heating capacity/Unit power input. (5) For basic units without 2-damper economizer. (6) For lower outdoor air temperature (+10 °C), in cooling mode, use low ambient kit (optional). (7) Unit without electric heater.
82
Commercial Air Conditioning |
83
Technology and ReliabiliTy
Ideal solutIon for refurbIshment and r22 unIts replacement
as well as for new applIcatIons
Standard protective devices: Flow switch/pressostat on hydraulic circuit HP pressure switch LP pressure switch Fuse holder
Energy saving EC fan motor
Advance scroll technology
Rotary or scroll hermetic compressor
WATER SOURCE HEAT PUMP RANGE
wat
er s
oU
rCe
H
eat
pU
mp
RA
nG
e
CW-AR 7-9-12 HRW 7-9-12 HRW 19 to 72 HRW 96 & 120 EWH 04 to 45
console or concealed versions for offices
and light shop
Very compact design for hotels and office
building, new & refurbishment
Shopping centers tertiary buildings & large complex
Shopping centers & large complex
R410A
82 83
ELECTRONIC CONTROL
Includes: a digital display unit status fault report and key functions such as:
- On/Off,- Selection of operating mode,- Room temperature display,- Fan speed selection,- Temperature set-point adjustment
control features and Benefits:
Room air temperature measurement Anti-short cycle for compressor protection Variable sequential start-up function to avoiding power surge
Emergency shut-down/stand-by/night setback Anti-freeze safety function High temperature safety function Fault reports HP pressure switch triggering, Water temperature fault (low & high limit) Anti-freeze protection. Motorized valve management Master/slaves
84
Commercial Air Conditioning |
85
HRWWatEr SourcE HEat PuMP
cooling capacity: from 1.9 to 30 kW Heating capacity: from 2.6 to 38 kW refrigerant: HFc 407c Sizes: 13 models, 5 casings
VeRSIONS: rc: cooling and heating St: cooling only SH: cooling and heating or electric heating rH: cooling and electric heating
CONFIGURATIONS: Horizontal concealed installation
PRODUCT ADVANTAGES High efficiency horizontal units with high coP. 5 optimized compact casing. Easy access to components through wide removable panels. in-line or perpenducular air blowing. Brazed stainless steelPlate heat exchanger for improved efficiency. Flow switch for antifreeze protection as standard. Bi-flow thermostatic expansion valve as standard. anti-corrosion treated drain pan. Float-type safety system to protect agains condensate overflow. Stand-alone StorM electronic control with rcl remote control.
MAIN OPTIONS rcW-2 mini-supervision station. ModBus communication interface board. 3-speed direct drive fan motor (up to 17 kW) or belt-driven fan with variable pitch pulley (above 17kW). g2 filter as standard, g3 in option*. 15 mm thick thermal and acoustical insulation. M1-class fire insulation. Electrical heater. Motorized water valve. general alarm dry contact. disconnect switch*. Front or lateral ducted plenum for air intake*. Fresh air intake. individual packaging*.
* Available on some models.
MAIN ACCESSORIES room sensor.
Operating limit fOr Standard unitHRW 07-12 HRW 19-72 HRW 96-120
Water inlet temperature
CoolingMin 18°C 18°C 20°C
Max 42°C 44°C 48°C
HeatingMin 13°C
Max 34°C
Return Air temperature
CoolingMin 21°C db/15°C wb
Max 32°C db/23°C wb 38°C db/28°C wb 38°C db/28°C wb
HeatingMin 15°C
Max 27°C 27°C 25°C
Maximum operating pressure 31 bars
84 85
hrw size 007 009 012reversible unit
cooling only unitCAPACITIES
total cooling capacity W 1941 2338 2974Sensible cooling capacity W 1441 1770 2253
Heating capacity W 2656 2784 3768VENTILATION
nominal airflow m³/h 440 520 650Motor power W 190 190 190Fan speeds Nbr 3 3 3
air filter number/Efficiency 1/G2 1/G2 1/G2air filter dimensions/thickness mm 600x200/20 600x200/20 600x200/20
HyDRAULIC CIRCUITPlate heat exchanger Nbr 1 1 1nominal water flow (1) l/s 0.116 0.142 0.194
cutoff water flow vs nominal water flow % 43 35 26WPd at nominal water flow (1) kPa 1 2 3
WPd at nominal water flow with valve (6) kPa 4 6 11Hydraulic connections inches ISO G 1/2" INT
condensate outlet - external ø mm 16 16 16REFRIGERANT CIRCUIT
number of circuit 1 1 1compressor type Rotary Rotary Rotary
ELECTRICALPower supply V/Ph/Hz 230/1/50 230/1/50 230/1/50
Power input - cooling mode (4) W 650 720 960Power input - heating mode (4) W 650 728 1010
Electrical heater W 1200 1600 2000Fan maximum current (ESP=0Pa) (7) A 0.46 0.57 0.83
compressor nominal current A 2.8 3 4compressor starting current A 16 16 18.9
SOUND LEVELSSound power level (8) dB(A) 44/47/49 47/49/51 49/51/54
Sound pressure level (9) dB(A) 37//40/42 40/42/44 42/44/47nr (9) dB(A) 32/35/37 35/37/39 37/39/42
DIMENSIONS lxWxH mm 900x530x239 900x530x239 900x530x239
WEIGHT unit weight kg 55 55 55
(1) Nominal cooling capacities based on: Air: 27°C DB/19°C WB, entering water temperature: 30°C. (2) Nominal heating capacities based on: Air: 20°C DB/15°C WB, entering water temperature: 20°C. (3) Protection by flow switch on units HRW 007, 009 & 012, and by differential pressure switch on units HRW 019 to 120. (4) Absorbed power (compressor + fan) at nominal conditions. (5) electric heating coil is an optional feature available on SH & RH versions. (6) Total water pressure drop with optional water valve fitted. (7) fan power supply: 230V/1Ph for HRW 007 to 072, 400V/3Ph for HRW 096 & 120. (8) Sound power level considering 1,5 m return and discharge duct and unit suspended at 1m. (9) Sound pressure considering an hypothetical installation and local attenuation of 7 dB.
options 007 009 012ELECTRICAL HEATER
capacity W 1200 W 1800 W 2000 WFILTRATION
g2 - M³ filter STD STD STDg2 - M1 filterg2 - M1 filter
PACKAGINGindividual
OTHER OPTIONSMain switch - - -
general alarm dry contact room sensor (Kit)
Modbus cardair fresh intake diam 100 mm *air fresh intake diam 150 mm *
Front plenumSide plenum
Motorized valve
accessories 007 009 012rcl remote controller** Code 7ACEl1378 7ACEl1378 7ACEl1378µBMS Code 7ACEl1303 7ACEl1303 7ACEl1303
* Only with return air plenum** one RCL is delivery with unit as standard with size 19 to 120
86
Commercial Air Conditioning |
87
hrw size 019 027 030 036 042 048 060 072reversible unit
cooling only unitCAPACITIES
total cooling capacity W 5278 7419 8691 10138 11366 12965 14344 17174Sensible cooling capacity W 4257 5824 6315 7278 8849 10051 10988 13536
Heating capacity W 5826 8342 9759 11036 14422 14904 16147 4970VENTILATION
nominal airflow m³/h 1250 1185 1490 1580 2040 2750 2840 3570Motor power W 145 145 210 245 320 550 550 550Fan speeds Nbr 3 3 3 3 3 3 3 3
air filter number/Efficiency 2/G2 2/G2 2/G2 2/G2 2/G2 2/G2 2/G2 2/G2air filter dimensions/thickness mm 365x300/25 365x300/25 385x350/25 385x350/25 450x440/25 450x440/25 450x440/25 450x440/25
HyDRAULIC CIRCUITPlate heat exchanger Nbr 1 1 1 1 1 1 1 1nominal water flow (1) l/s 0,256 0,428 0,49 0,564 0,72 0,784 0,93 1,09
cutoff water flow vs nominal water flow % 50 50 47 45 39 38 35 41WPd at nominal water flow (1) kPa 13 17 23 25 33 34 40 61
WPd at nominal water flow with valve (6) kPa 16 23 33 39 55 60 77 112Hydraulic connections inches ISO G 3/4" INT
condensate outlet - external ø mm 19 19 19 19 19 19 19 19REFRIGERANT CIRCUIT
number of circuit 1 1 1 1 1 1 1 1compressor type Rotary Scroll Scroll Scroll Scroll Scroll Scroll Scroll
ELECTRICALPower supply V/Ph/Hz 230/1/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50
Power input - cooling mode (4) W 1557 2118 2658 3044 3584 4200 4989 6280Power input - heating mode (4) W 1611 2332 2983 3460 3920 4300 5150 7347
Electrical heater W 2250 3750 3750 4500 5500 6500 7500 9000Fan maximum current (ESP=0Pa) (7) A 1,5 1,5 2,6 2,4 3,55 4,7 4,7 6,9
compressor nominal current A 6,6 3,7 4,5 5,4 5,7 7 7,5 10,6compressor starting current A 33 32 40 46 51,5 54 65,5 101
SOUND LEVELSSound power level (8) dB(A) 51/54/58 54/56/57 53/54/57 53/56/58 54/56/58 55/59/63 55/59/63 57/60/63
Sound pressure level (9) dB(A) 44/47/51 47/49/50 46/47/50 46/49/51 47/49/51 48/52/56 48/52/56 50/53/56nr (9) dB(A) 39/42/46 42/44/45 41/43/45 41/44/46 42/44/46 43/47/49 43/47/49 45/48/51
DIMENSIONS lxWxH mm 900x600x439 1050x660x460 1050x660x460 1050x660x460 1250x705x513 1250x705x513 1250x705x513 1250x705x513
WEIGHT unit weight kg 80 100 100 112 133 140 144 149
(1) Nominal cooling capacities based on: Air: 27°C DB/19°C WB, entering water temperature: 30°C. (2) Nominal heating capacities based on: Air: 20°C DB/15°C WB, entering water temperature: 20°C. (3) Protection by flow switch on units HRW 007, 009 & 012, and by differential pressure switch on units HRW 019 to 120. (4) Absorbed power (compressor + fan) at nominal conditions. (5) electric heating coil is an optional feature available on SH & RH versions. (6) Total water pressure drop with optional water valve fitted. (7) fan power supply: 230V/1Ph for HRW 007 to 072, 400V/3Ph for HRW 096 & 120. (8) Sound power level considering 1,5 m return and discharge duct and unit suspended at 1m. (9) Sound pressure considering an hypothetical installation and local attenuation of 7 dB.
options 019 027 030 036 042 048 060 072ELECTRICAL HEATER
capacity W 2250 W 3000 W 3750 W 4500 W 5400 W 6500 W 7500 W 9000 WFILTRATION
g2 - M³ filter STD STD STD STD STD STD STD STDg2 - M1 filterg2 - M1 filter
PACKAGINGindividual
OTHER OPTIONSMain switch
general alarm dry contact room sensor (Kit)
Modbus cardair fresh intake diam 100 mm *air fresh intake diam 150 mm *
Front plenumSide plenum
Motorized valve
accessories 019 027 030 036 042 048 060 072rcl remote controller** Code 7ACEl1378 7ACEl1378 7ACEl1378 7ACEl1378 7ACEl1378 7ACEl1378 7ACEl1378 7ACEl1378µBMS Code 7ACEl1303 7ACEl1303 7ACEl1303 7ACEl1303 7ACEl1303 7ACEl1303 7ACEl1303 7ACEl1303
* Only with return air plenum** one RCL is delivery with unit as standard with size 19 to 120
86 87
hrw size 096 120reversible unit
cooling only unitCAPACITIES
total cooling capacity W 21743 29951Sensible cooling capacity W 17986 24413
Heating capacity W 5380 7163VENTILATION
nominal airflow m³/h 4700 5600Motor power W 1100 1500Fan speeds Nbr - -
air filter number/Efficiency 2/G2 2/G2air filter dimensions/thickness mm 620x650/25 620x650/25
HyDRAULIC CIRCUITPlate heat exchanger Nbr 1 1nominal water flow (1) l/s 1,35 1,78
cutoff water flow vs nominal water flow % 44 30WPd at nominal water flow (1) kPa 55 114
WPd at nominal water flow with valve (6) kPa 133 250Hydraulic connections inches ISO G 1 1/4"
condensate outlet - external ø mm 22 22REFRIGERANT CIRCUIT
number of circuit 1 1compressor type Scroll Scroll
ELECTRICALPower supply V/Ph/Hz 400/3+N/50 400/3+N/50
Power input - cooling mode (4) W 6317 8547Power input - heating mode (4) W 7895 10224
Electrical heater W 13000 16000Fan maximum current (ESP=0Pa) (7) A 2,5 4,1
compressor nominal current A 11,4 14,8compressor starting current A 111 118
SOUND LEVELSSound power level (8) dB(A) 68 69
Sound pressure level (9) dB(A) 61 62nr (9) dB(A) 56 57
DIMENSIONS lxWxH mm 1680x955x770 1680x955x770
WEIGHT unit weight kg 253 262
(1) Nominal cooling capacities based on: Air: 27°C DB/19°C WB, entering water temperature: 30°C. (2) Nominal heating capacities based on: Air: 20°C DB/15°C WB, entering water temperature: 20°C. (3) Protection by flow switch on units HRW 007, 009 & 012, and by differential pressure switch on units HRW 019 to 120. (4) Absorbed power (compressor + fan) at nominal conditions. (5) electric heating coil is an optional feature available on SH & RH versions. (6) Total water pressure drop with optional water valve fitted. (7) fan power supply: 230V/1Ph for HRW 007 to 072, 400V/3Ph for HRW 096 & 120. (8) Sound power level considering 1,5 m return and discharge duct and unit suspended at 1m. (9) Sound pressure considering an hypothetical installation and local attenuation of 7 dB.
options 096 120ELECTRICAL HEATER
capacity W 13000W 16000WFILTRATION
g2 - M³ filter - -g2 - M1 filter STD STDg2 - M1 filter - -
PACKAGINGindividual
OTHER OPTIONSMain switch
general alarm dry contact room sensor (Kit)
Modbus cardair fresh intake diam 100 mm *air fresh intake diam 150 mm *
Front plenumSide plenum
Motorized valve
accessories 096 120rcl remote controller** Code 7ACEl1378 7ACEl1378µBMS Code 7ACEl1303 7ACEl1303
* Only with return air plenum** one RCL is delivery with unit as standard with size 19 to 120
88
Commercial Air Conditioning |
89
EWHWatEr SourcE HEat PuMP
cooling capacity: from 3.9 to 43 kW Heating capacity: from 4.3 to 58 kW refrigerant: r410a Size: 11 models, 7 casings
CONFIGURATIONS: Horizontal concealed installation
PRODUCT ADVANTAGES High efficiency horizontal units with high coP. Environment-friendly r410a refrigerant. Fitted with high and low pressure switches, refrigerant leakage and water temperature protections. Stand-alone, local or centralized control. Easy installation and servicing. low sound level.
MAIN ACCESSORIES Wired remote control Wireless remote control Master control network board 15m communication link 12V power supply rS485/rS422 adaptor board data zone control Pc monitoring tool
Operating limit fOr Standard unit
Water inlet temperature
CoolingMin 10 °C
Max 40°C
HeatingMin 10°C
Max 30°C
Return Air temperature
CoolingMin 16°C
Max 32°C db/23°C wb
HeatingMin 15°C
Max 27°C
Maximum operating pressure 35 bars
R410A
new
88 89
ewh size 04 05 06 07 10 13 15 22 30 38 45CAPACITIES
total cooling capacity kW 4.01 5.55 6.63 7.48 10.56 14.86 15.88 21.50 28.60 37.50 43.00Heating capacity kW 3.90 5.44 6.49 7.33 10.56 14.86 15.88 21.50 28.60 37.50 43.00
VENTILATION nominal airflow m³/h 800 950 1100 1260 2030 2500 2650 4000 5200 7000 8000
External static pressure Pa 30 80 120 150HyDRAULIC CIRCUIT
Water side heat exchanger type Coaxial nominal water flow (1) m³/h 0.85 1.17 1.46 1.61 2.12 3.1 3.4 4.8 6.4 8.3 9.5
WPd at nominal water flow (1) kPa 29 16.3 23.9 31.5 43.8 33.7 35.3 60 42 54 85Hydraulic connections inches Rc 3/4” R 1-1/4”
condensate outlet - external ø inches G3/4” G1”REFRIGERANT CIRCUIT
refrigerant type R410A compressor type Rotary Scroll
ELECTRICALPower supply V/Ph/Hz 230/1/50 400/3N/50
Power input - cooling mode W 982 1389 1734 1930 2330 3750 4070 5500 7400 9530 11150Power input - heating mode W 1085 1496 1849 2122 2330 4400 4700 6100 8600 11050 13190
SOUND LEVELSSound pressure level dB(A) 39/40/41 41/42/43 42/43/44 43/44/45 45/46/47 46/47/48 47/48/49 50 52 55 57
DIMENSIONS l x W x H mm 830x531x382 1024x592x436 1124x650x510 1313x747x512 1376x852x592 1808x1100x720 2059x1110x737
WEIGHT unit weight kg 57 82 84 88 111 155 158 180 330 370 380
(1) Nominal cooling capacities based on: Air: 27°C DB/19°C WB . water In/Out: 30/35°C (2) Nominal heating capacities based on: Air: 20°C DB/15°C WB . water In/Out: 20/35°C
PRODUCT CODES: ON REQUEST
ACCESSORy CODE 04 05 06 07 10 13 15 22 30 38 45
Wired remote controller Code C03027600 C03027700 Wireless remote controller Code 467240022
receiver assembly Code C03027400SySTEM: GROUP CONTROL
network board Code C03542000 Master controller Code C03541900
Wire communication 15 m Code C03540210 Power supply Box 12V Code C03543000
Wired remote controller Code C03027600 C03027700 Wireless remote controller Code 467240022
receiver assembly Code C03027400SySTEM: CENTRAL CONTROL WITH PC
network board Code C03542000 transfer card adapter
rS485/232 Code C03546201
Zone data collect controller Code C03542100 Pc Monitor tool Code C03546202
Wired remote controller Code C03027600 C03027700 Wireless remote controller Code 467240022
receiver assembly Code C03027400
90
Commercial Air Conditioning |
91
CW-ARWatEr SourcE HEat PuMP - cooling and HEating
cooling capacity: from 1.9 to 2.7 kW Heating capacity: from 2.4 to 3.2 kW refrigerant: HFc 407c Sizes: 3 models
VeRSIONS: car: standard with cabinet carB: low height with cabinet nu: standard without cabinet nuB: low height without cabinet
CONFIGURATIONS: Vertical console cabinet Vertical concealed without cabinet
PRODUCT ADVANTAGES High efficiency vertical units with high coP. Harmonuous and aesthetic ral9010 painted cabinet design. Streamlined design and elaborate finish enabling harmonious integration. low consumption Ec fan motor or 3-speed ac fan motor. Stand-alone StorM electronic control with rcl remote control. Brazed stainless steelPlate heat exchanger for improved efficiency. Easy access to components through front panel. Ease of installation through selection of service side. direct access to Schrader valves (HP & BP). Flow switch for antifreeze protection as standard. anti-corrosion treated drain pan.
MAIN OPTIONS rcW-2 mini-supervision station. ModBus communication interface board. l/r lateral, back or bottom hydrualic connections. l/r lateral electrical connection. g2 filter. 15 mm thick thermal and acoustical insulation. lonWorks control. bottom return air with feet or front air intake. HP & BP pressure switches. general alarm dry contact. disconnect switch. thermostat.
Operating limit fOr Standard unit
Water inlet temperature
CoolingMin 23°C
Max 42°C
HeatingMin 12°C
Max 34°C
Return Air temperature
CoolingMin 21°C db/15°C wb
Max 32°C db/23°C wb
HeatingMin 15°C
Max 27°C
Maximum operating pressure 3 bars
new
90 91
cw-ar size 07 09 12reversible unit
CAPACITIEStotal cooling capacity W 1942 2136 2743
Sensible cooling capacity W 1526 1775 2340Heating capacity W 2431 2542 3156
VENTILATION nominal airflow m³/h 400 460 510
Motor power W 75 75 75Fan speeds Nbr 3 3 3
air filter number/Efficiency 1/G2air filter (Front) dimensions/thickness mm 660x205/6
air filter (Bottom) dimensions/thickness mm 595x187/6HyDRAULIC CIRCUIT
Plate heat exchanger Nbr 1nominal water flow (1) l/s 0,119 0,133 0,171
cutoff water flow vs nominal water flow % 44 40 31WPd at nominal water flow (1) kPa 5 3,4 12
Hydraulic connections inches ISO G 1/2" INTcondensate outlet - external ø mm 15x20
REFRIGERANT CIRCUITnumber of circuit 1
compressor type RotaryELECTRICAL
Power supply V/Ph/Hz 230/1/50Power input - cooling mode (4) W 598 647 892Power input - heating mode (4) W 710 720 954
Fan maximum current A 0,2 0,25 0,3compressor nominal current A 2,8 3 4compressor starting current A 16 16 18,9
SOUND LEVELS (LS/MS/HS)Sound power level dB(A) 49/50/51 50/51/53 51/53/54
Sound pressure level (5) dB(A) 41/42/43 42/43/45 43/45/46nr (5) dB(A) 36/17/38 37/38/40 38/40/41
DIMENSIONS (LxWxH) console (Std) (6) mm 1138x251x821
concealed (Std) (6) mm 1086x229x769WEIGHT
console (Std) kg 70 73 75concealed (Std) kg 55 58 60
(1) Nominal cooling capacities based on: Air: 27°C DB/19°C WB, entering water temperature: 30°C. (2) Nominal heating capacities based on: Air: 20°C DB/15°C WB, entering water temperature: 20°C. (3) Protection by flow switch on units HRW 007, 009 & 012, and by differential pressure switch on units HRW 019 to 120. (4) Absorbed power (compressor + fan) at nominal conditions. (5) Sound pressure considering a local of 100 m³, a reverberation time of 0,5 sec and a distance of 1 m. (6) Feet included.
optionsCAbINET
nu No cabinet STDnuB low No Cabinet STDcar Std cabinet
carB low cabinetHyDRAULIC CONNExIONS
HB Bottom STDHa Back STDHd Right side STDHg left side
ELECTRICAL CONNExIONSEd Right side STDEg left side
FILTRATIONFF Front STDFd Bottom
CONTROLStorM STD STORM + RCl STD
rB TerminalsTHERMOSTAT
tn Without remote terminals -tM remote terminal - mountedtl remote terminal - not mounted STD
OPTIONS MPg MPG grille for cabinet
Ec EC Motor on requestalar General remote alarm contactdiSJ Thermal overloadMiu MIU Card
92
Commercial Air Conditioning |
93
MODERN AND HIGH EFFICIENCY TECHNOLOGIES
Complete, modern, and friendly control to manage the full parameters of the chillers, and outside communication also
Counter flow evaporator (here on AQSL range)
Special inverter fanlow sound level (option)
Blue fins condensers (heat pump version) for a better efficiency and easier defrosting cycle
Electronic expansion valve for a perfect control of the supeheat
Micro channel condenser (cooling only) for a better efficiency and low weight
Advance scroll technology
Advance screw technology
AIR COOLED
AXIAL
R410A R407C
SCROLL SCROLL
R134A R410A
SCREW SCROLL
CENTRIFUGAL CONDENSING
WATER COOLED
R134A
SCREW
R410A
SCROLL
AXIAL
CHILLERS RANGE COOLING & HEAT PUMP VERSION
6/700 KW 300/1646 KW 25/125 KW 25/350 KW 300/1118 KW 8/312 KW
air
an
d w
ater
Co
ole
d
CHil
ler
s R
An
Ge A lArge And flexible rAnge
92 93
Full units are tested
All our chiller range is Eurovent certified
REFRIGERANT OZONE FRIENDLY
Powerfull test facilities, each unit is individually tested (hydraulic and electrical connection)
Witness test available from 0°C up to 50°C external conditions up to 500 kW cooling capacity
all our chiller range is fully developped around the main following points:
High level of performances (mainly class A or B)
Flexibility on choice for the finishing level of the unit
- Basic (Bln) - low sound level (ln) - Extra low noise version (Eln) - High efficiency level (HSE) - High external temperature (up to 55°c) - Heat recovery - desuperheater
Also a full range of accessories and options permit to perfectly adapt the chiller to the site as:
- Hydraulic kit 1 or 2 or 3 pumps onboard - Water tank onboard - communication gateway
(Modbus, lon, Bacnet) - Special protection on condensers
(black epoxy, cu/cu, ...) - remote monitoring - ...
class
Airwell Group is engaged in a permanent research of energy saving on and all around his product range.
This logo is the witness of this voluntary gait in terms of:
Engagement
Efficiency
Energy
R410A
94
Commercial Air Conditioning |
95
Mini-chiller MQH 6-18air-to-WatEr HEat PuMP
cooling capacity: from 5.4 to 17.8 kW Heating capacity: from 6.1 to 20.1 kW refrigerant: r410a Sizes: 3 sizes 1-phase, 6 sizes 3-phase
MAIN FeATUReS: auto-adaptive function Extended operation limits Pump and water filter included
APPLICATIONS: Fan-coil cooling/Heating floor
PRODUCT ADVANTAGES r410a. rotary/Scroll compressors. compact microprocessor based iltc control, easy to use. double set point or day & night mode with 3 different selectable mode: Energy saving, low noise, energy saving & reduced noise. Plug and Play unit: Hydraulic kit integrated into the unit including expansion tank, centrifugalwater pump, safety valve, vent valve, drain valve and pressure gauge.
MAIN OPTIONSSupplied as standard: aVM rubber pad. Water filter. BMS interface, ModBus protocol rS485.
MAIN ACCESSORIES External water tank. Water stop valves.
Operating limit fOr Standard unitCOOLING MODE
Leaving water temperature without glycol 5/18°C
Outdoor air temperature -10/46°C
HEATING MODE
Leaving water temperature 20/50°C
Outdoor air temperature -10/20°C
R410A
94 95
mQh Bln siZes 6 8m 8t 10m 10t 12 14 16 18COOLING CAPACITy KW 5.4 7.6 7.6 9.7 9.7 12.1 13.1 15.1 17.8
Power input (compressor) kW 1.9 2.6 2.6 3.1 3.1 4.4 4.5 5.6 7 total EEr* 2.7 2.8 2.8 2.9 2.9 2.6 2.7 2.6 2.4
HEATING CAPACITy KW 6.1 8.5 8.5 11.1 11.1 13.8 15.7 17.9 20.1
Power input (compressor) kW 2.1 2.8 2.8 3.4 3.4 4.6 4.9 5.7 6.6 coP* 2.7 2.9 2.9 3.0 3.0 2.8 3.0 3.0 2.9
Power supply 230V/1/50Hz 400V/3+N/50Hz 230V/1/50Hz 400V/3+N/50Hz Startup type Direct Direct Direct Direct Direct Direct Direct Direct Direct
REFRIGERANT
type R410A number of refrigerant circuit 1 1 1 1 1 1 1 1 1 COMPRESSORS
number 1 1 1 1 1 1 1 1 1 type Rotary Rotary Rotary Rotary Rotary Scroll Scroll Scroll Scroll
EVAPORATOR
nombre 1 1 1 1 1 1 1 1 1 type Plate Plate Plate Plate Plate Plate Plate Plate Plate
COIL
number 1 1 1 1 1 1 1 1 1 FanS
number 1 1 1 2 2 2 2 2 2WATER CONNECTIONS
type Female gas threaded inlet/outlet diameter inches 3/4" 3/4" 3/4" 1" 1" 1" 1" 1" 1"
WEIGHT
Shipping weight kg 102 113 113 152 152 165 182 185 189 DIMENSIONS
length mm 951 951 951 951 951 951 951 951 951 Width mm 413 413 413 413 413 413 413 413 413
Height mm 863 863 863 1265 1265 1265 1365 1365 1365 ACOUSTICAL DATA (NORMAL MODE)
Sound power level dB(A) 66 69 69 68 68 70 70 70 72 Sound pressure level at 1m dB(A) 55 57 57 56 56 59 59 59 62
96
Commercial Air Conditioning |
97
MQHD 06 08 10air-to-WatEr HEat PuMP
Heating capacity: from 1.8 to 11.8 kW cooling capacity: from 2.4 to 14.4 kW refrigerant: r410a
MAIN FeATUReS: compressor inverter Management of domestic hot water leaving water temperature up to 55°c
PRODUCT ADVANTAGES inverter rotary compressor optimized heat exchanger for heating operation:
• advance electronic control• Electronic expansion valve• Blue-fin treatment as standard• Fan speed controller std• Soft starter std
inverter fans Hydrokit included (pump, expansion vessel, safety devices) Fan coil application Floor application domestic hot water application Water filter as std Water pressure differential switch Modbus protocol rS 485 aVM rubber pad coil guards
MAIN ACCESSORIES room thermostat Electric heater kit (2-4-6 kW)
Operating limit fOr Standard unitCOOLING MODE
Max. outdoor air temperature 46°C
Min. outdoor air temperature 10°C
Min. leaving water temperature at A40 5°C
Max. leaving water temperature at A40 20°C
HEATING MODE
Max leaving water temperature at A2 55°C
Max leaving water temperature at A-15 55°C
Min. outdoor air temperature -15°C
Max. outdoor air temperature at W55 35°C
R410A
new
96 97
mQhd sizes 06 08 10mHEATING CAPACITy KW 1.8 – 7.1 2.9 – 9.1 3.5 -11.8
Heating cap. at nominal point a7/W35 kW 6.0 7.7 10.0coP (according to En 14511) at a7/W35 3.95 3.90 4.00
COOLING CAPACITy KW 2.4-8.1 5.3-9.6 2.5-14.4
cooling cap. at nominal point a35/W18 kW 6.00 8.00 9.80EEr at a35/W18 4.30 3.75 4.00
Sound power at a7/W35 dB(A) 63 64 69Fan speed Variable
domestic hot water Temperature at A2 inside tank > 50 °C by heat pump onlyrated voltage heat pump 230 V/1/50 Hz
compressor DC InverterExpansion valve Electronic expansion valve
Factory refrigerant charge g 1550 1760 2900Heat exchanger type Brazed plate heat exchanger
Safety valve (heating circuit) Open at 3.0 barManometer (heating circuit) Integrated
Heating circuit pump ~ 230 VMechanical expansion vessel capacity litres 2 2 5
CONNECTION (WATER )
type Female Female Femaleinlet connection diameter inches 3/4” 3/4” 3/4”
outlet connection diameter inches 3/4” 3/4” 3/4”condensate flow On the bottom
COIL
type Seamless copper tubes with hydrophilic finsDIMENSIONS AND WEIGHT
length mm 950 950 1241Width mm 340 340 401
Height mm 864 864 1382Weight kg 82 82 152
A: Outdoor air temperature.W: Water temperature.
98
Commercial Air Conditioning |
99
Aqu@Logic DCI 20-25-30 air-to-WatEr HEat PuMP
cooling capacity: from 19.6 to 28.8 kW Heating capacity: from 18.7 to 25.7 kW refrigerant r410a
MAIN FeATUReS: Scroll compressor inverter class a Management of domestic hot water leaving water temperature up to 55°c
PRODUCT ADVANTAGES inverter 3-phase brushless compressor (more reliable and efficient) with variable frequency (range 20-120 Hz) optimized heat exchanger for heating operation:
• Blue-fin treatment as standard• optimized fin space• counter-flow heat exchanger both in cooling and heating mode
Electronic expansion valve Power factor capacitor std Fan speed controller std Soft starter std inverter fans Hydrokit included (pump, expansion vessel, safety devices) Start-up current = 5,2 a for all sizes
MAIN ACCESSORIES112 L buffer tank: Supplied as separate accessory to be mounted underneath the unit Water pipe connection included
Operating limit fOr Standard unitCOOLING MODE
Leaving water temperature (without glycol) 5°C
Leaving water temperature (with glycol) -7°C
Outside max. external temperature 46°C
HEATING MODE
Leaving water temperature 55°C
Outside max. external temperature -15°C
R410A
new
98 99
aQh dci sizes 20 25 30cooling capacity (min/nom/max) a35/W18 kW 9.60/19.6/25.7 12.8/24.4/32.4 13.7/28.8/33.4
EEr a35/W18 5.01 4.77 4.23cooling capacity (min/nom/max) a35/W7 kW 6.7/19.6/24.1 9.0/24.4/28.3 10.2/28.7/30.7
EEr a35/W18 3.24 3.26 3.04Heating capacity (min/nom/max) a7/W35 kW 8.00/18.7/25.8 8.71/22.3/31.4 9.50/25.7/32.9
coP a7/W35 4.00 4.13 3.98Heating capacity (min/nom/max) a7/W45 kW 5.4/18.7/20.9 8.2/22.3/30.8 9.1/25.7/31.7
coP a7/W35 3.00 3.11 3.01Sound power level dB(A) 74 75 75
Power supply V/ph/hZ 400/3 + N/50number of refrigerant circuits 1
Part load steps % SteplessREFRIGERANT
type R410Acharge(1) 7.5 9.0 9.0
COMPRESSORtype Scroll (BlDC Motor)
number 1Startup type Inverter
oil type PVEEVAPORATOR
type Platenumber 1
Water flow rate l/sRefer to hydraulic circuit data
Water pressure drop kPaFANS
type Axialnumber 2
Speed rpm 630airflow rate l/s 3.4 3.2 3.2input power kW 0.6 0.6 0.6
COILtype Finned tubes
number 1Frontal surface mm 1350 x 1500
rows 2 3 3PUMP
type Centrifugalnumber 1
Speed rpm 2800Water flow rate l/s
Refer to hydraulic circuit dataWater available static pressure kPa
WATER CONNECTIONStype Male Gas threated
inlet diameter inches 1” 1/2outlet diameter inches 1” 1/2
Water drain connection inches 3/8”WEIGHT
Shipping weight kg 269 285 285operating weight kg 262 279 279
DIMENSIONSlenght mm 1477Width mm 538
Height mm 1625ELECTRICAL DATA
Power supply V/ph/Hz 400±(10%)/3 + N/50Maximum power input kW 12.0 14.3 14.3
Maximum current input A 24.9 30.1 30.1Start-up current A 5.2 5.2 5.2
External fuses A 32 32 32Max. cable section(2) mm2 10 10 10
HEAT ExCHANGER RESISTANCEPower supply V/ph/Hz 230±(10%)/1/50
Maximum power input W 35
A: Outdoor air temperature. W: Water temperature.(1) Indicative value. Always refer to the value specified on the unit’s label.(2) The dimensioning of the unit’s power cables is the responsability of the installer, who shall consider: the rating, the maximum working temperature in the room, the type of insulation and the cable laying, the maximum lenght of the power supply line.
100
Commercial Air Conditioning |
101
Aqu@Logic AQL 20-75air-coolEd cHillEr
cooling capacity: from 19.1 to 75 kW refrigerant: r410a Sizes: 10
MAIN FeATUReS 2 scroll compressors/1 refrigerant circuit auto-adaptive function to reduce water content in the piping system
Hydronic kit included VeRSIONS: Std: Standard SiF: ducted installation (40-75 sizes only)
ACOUSTIC OPTIONS: Bln Basic low noise Eln Extra low noise (40-75 sizes only)
PRODUCT ADVANTAGES r410a refrigerant. Simpler refrigerant circuit layout. low sound level for Bln unit, very low sound level for Eln unit (only 40-75 sizes). great accessibility to internal components for service operations. new display on external panel allowing the complete control of the unit. Sight glass inspection hole allowing to check the sight glass without removing any panel. Wide operating limits. High temperature operation up to 50°c. units are suitable for low water temperature applications with leaving water temperature of -8°c (min.). double water set point. iltc (intelligent liquid temperature control) controller that allows to reduce the use of an external water tank. return and leaving water temperature control logic. optional plug and play hydraulic kit for last minute configuration equipped (only 40-75 sizes).
Standard configuration: Pump equipped as standard (only 20-30). Phase sequence monitor supplied as standard. rubber pads supplied as standard. Water filter and flow swtich (only 40-75 sizes) supplied as standard.
MAIN OPTIONS coil with blue fins,with “Fin guard Silver” or black epoxy treatment. Soft starter. desuperheater (only 40-75 sizes). Power supply without neutral kit, (only 40-75 sizes). automatic circuit breaker (only 40-75 sizes). compressor overload protection, (only 40-75 sizes). Hydraulic options (1P, 2P, 1Pt, 2Pt) (only 40-75 sizes).
MAIN ACCESSORIES antivibration kit (only 40-75 sizes). remote on/off control. Fan speed control kit. no pump kit,that allows to switch from a pump equipped unit to a no pump unit.(only 20-35 sizes). gauge kit. Hydro kit 112 litres (only 20-35 sizes). Flow switch (only 20-35 sizes). in/out valve kit. ModBus protocol kit for BMS. Power factor correction capacitors. Sequencer for up to 4 chillers installation. compressor soundproof jackets (this option is standard on Eln version (only 40-75 sizes).
Operating limit fOr Standard unitCOOLING MODE Sizes
Leaving water temperature without glycol 5/18°C
Leaving water temperature with glycol -8/5°C
Outdoor air temperature BLN -10/50°C 20-35
Outdoor air temperature BLN -18/46°C 40-75
Outdoor air temperature eLN -18/43°C 40-75
Outdoor air temperature SIF-20/50°C 40-50
-20/48°C 60-75
NOTESOperating limits are referred to full load Maximum % glycol (ethylenic or propilenic): 40%
R410A
100 101
aQl Bln siZes 20 25 30 35COOLING CAPACITy KW 19.1 24.9 30.9 35.9
Power input (compressor) kW 5.50 7.51 10.0 11.2 total EEr* 3.13 3.07 2.92 3.04
ESEEr 4.86 4.29 4.37 4.08 Power supply 400V/3+N/50Hz 400V/3+N/50Hz 400V/3+N/50Hz 400V/3+N/50Hz
Startup type Direct Direct Direct Direct REFRIGERANT
type R410A number of refrigerant circuit 1 1 1 1
COMPRESSORS number 2 2 2 2
type Scroll Scroll Scroll Scroll EVAPORATOR
nombre 1 1 1 1 type Plate Plate Plate Plate
COIL number 1 1 1 1
FANS number 2 2 2 2
WATER CONNECTIONS type Male gas threaded
inlet/outlet diameter inches 1" 1/2 1" 1/2 1" 1/2 1" 1/2 WEIGHT
operating kg 276 294 302 316 DIMENSIONS
length mm 1477 1477 1477 1477 Width mm 538 538 538 538
Height mm 1625 1625 1625 1625 ACOUSTICAL DATA (NORMAL MODE)
Sound power level dB(A) 74 75 75 75 Sound pressure level at 10m (1) dB(A) 43 44 44 44
(1) Sound pressure calculated at 10 m. Sound pressure levels refer to ISO standard 3744 with parallepiped shape.
aQl Bln siZes 40 45 50 60 65 75 COOLING CAPACITy KW 40.0 44.0 51.0 60.0 67.9 75.8
input Power (compressor) kW 12.7 14.8 17.2 18.1 21.0 25.4 total EEr* 2.92 2.79 2.81 2.99 2.95 2.77
ESEEr 4.32 4.11 4.14 4.27 4.34 3.99 Power Supply 400V/3+N/50Hz 400V/3+N/50Hz 400V/3+N/50Hz 400V/3+N/50Hz 400V/3+N/50Hz 400V/3+N/50Hz
Startup type Direct Direct Direct Direct Direct Direct
aQl eln siZes 40 45 50 60 65 75 COOLING CAPACITy KW 38.7 42.4 48.7 58.0 63.1 72.8
input Power (compressor) kW 13.4 15.7 18.4 19.0 21.9 26.9 total EEr* 2.77 2.61 2.57 2.86 2.72 2.58
ESEEr 4.09 3.84 3.79 4.09 4.00 3.73
aQl sif siZes 40 45 50 60 65 75 COOLING CAPACITy KW 42.1 46.6 54.3 60.8 66.4 77.0
input Power (compressor) kW 11.7 13.5 15.5 17.7 20.3 24.7 total EEr* 2.93 2.89 2.99 2.98 2.89 2.81
ESEEr 4.33 4.24 4.39 4.27 4.13 3.99 REFRIGERANT
type R410A number of refrigerant circuits 1 1 1 1 1 1
COMPRESSOR number 2 2 2 2 2 2
type Scroll Scroll Scroll Scroll Scroll Scroll EVAPORATOR
number 1 1 1 1 1 1 type Plate Plate Plate Plate Plate Plate
COIL number 1 1 1 1 1 1
FANS number 1 1 1 1 1 1
WATER CONNECTIONS (EVAPORATOR) type Male GAS threaded
inlet/outlet diameter inches 2" 2" 2" 2" 2" 2" WATER CONNECTIONS (DESUPERHEATER)
type Male GAS threaded inlet/outlet diameter inches 1" 1" 1" 1" 1" 1"
WEIGHT operating Weight** kg 413 421 446 489 496 502
DIMENSIONS length mm 1750 1750 1750 2200 2200 2200 Width mm 1100 1100 1100 1100 1100 1100
Height mm 1580 1580 1580 1580 1580 1580 ACOUSTICAL DATA (NORMAL MODE)
Sound Power level Bln dB(A) 80.5 81.0 81.0 85.5 85.6 85.8 Sound Pressure level (1) Bln dB(A) 48.9 49.4 49.4 53.8 53.8 54.1
Sound Power level Eln dB(A) 74.0 75.3 75.3 78.0 78.5 79.0 Sound Pressure level (1) Eln dB(A) 42.4 43.7 43.7 46.3 46.8 47.3
Sound Power level SiF*** dB(A) 95.2 95.2 95.2 95.3 95.3 95.3 Sound Pressure level (1) SiF dB(A) 63.6 63.6 63.6 63.6 63.6 63.6
(1) Sound pressure calculated at 10 m. Sound pressure levels refer to ISO standard 3744 with parallepiped shape.(*) Gross value According to eurovent standard.(**) Without buffer tank + pumps.(***) Sound data referred to a fan speed of 1110 rpm.
102
Commercial Air Conditioning |
103
Aqu@Logic AQH 20-75air-to-WatEr HEat PuMP
cooling capacity: from 19.1 to 75.8 kW Heating capacity: from 18.7 to 84.9 kW refrigerant: r410a Sizes: 10
MAIN FeATUReS: 2 scroll compressors/1 refrigerant circuit auto-adaptive function to reduce water content in the piping system
Hydronic kit includedVeRSIONS: Std: Standard SiF: Special inverter Fan (40-75 sizes only)
ACOUSTIC OPTIONS: Bln Basic low noise Eln low noise (40-75 sizes only)
PRODUCT ADVANTAGES r410a refrigerant. Simpler refrigerant circuit layout. low sound level for Bln unit, very low sound level for Eln unit (only 40-75 sizes). great accessibility to internal components for service operations. new display on external panel allowing the complete control of the unit. Sight glass inspection hole allowing to check the sight glass without removing any panel. Wide operating limits. High temperature operation up to 50°c. units are suitable for low water temperature applications with leaving water temperature of -8°c (min.). double water set point. iltc (intelligent liquid temperature control) controller that allows to reduce the use of an external water tank. return and leaving water temperature control logic. optional plug and play hydraulic kit for last minute configuration equipped (only 40-75 sizes).
Standard configuration: Pump equipped as standard (only 20-30). Phase sequence monitor supplied as standard. rubber pads supplied as standard. Water filter and flow swtich (only 40-75 sizes) supplied as standard.
MAIN OPTIONS coil with blue fins. coil with “Fin guard Silver” treatment. coil with black epoxy treatment. Soft starter. desuperheater (only 40-75 sizes). Power supply without neutral kit, (only 40-75 sizes). automatic circuit breaker (only 40-75 sizes). compressor overload protection, (only 40-75 sizes). Hydraulic options (1P, 2P, 1Pt, 2Pt) (only 40-75 sizes). Electric heaters (12, 24 or 36 kW) inside buffer tank to ensure extra heating (only 40-75 sizes).
MAIN ACCESSORIES antivibration kit (only 40-75 sizes). remote on/off control (only 40-75 sizes). Fan speed control kit. no pump kit,that allows to switch from a pump equipped unit to a no pump unit. gauge kit. Hydro kit 112 litres (only 20-35 sizes). Flow switch (only 20-35 sizes). in/out valve kit. remote on/off control (only 40-75 sizes). ModBus protocol kit for BMS. Power factor correction capacitors. Sequencer for up to 4 chillers installation. compressor soundproof jackets (this option is standard on Eln version (only 40-75 sizes).
Operating limit fOr Standard unitCOOLING MODE SizesLeaving water temperature without glycol 5/18°CLeaving water temperature with glycol -8/5°COutdoor air temperature BLN -10/50°C 20-35Outdoor air temperature BLN -18/47°C 40-75Outdoor air temperature eLN -18/43°C 40-75
Outdoor air temperature SIF-20/50°C 40-50-20/46°C 40-50
HEATING MODELeaving water temperature 20/55°COutdoor air temperature -10/20°COutdoor air temperature eLN -8/20°COutdoor air temperature SIF -11/20°C
NOTES Operating limits are referred to full load.Maximum % glycol (ethylenic or propilenic): 40%.
R410A
102 103
aQh Bln siZes 20 25 30 35COOLING CAPACITy KW 17.8 23.2 28.8 33.5
Power input (compressor) kW 5.83 7.69 10.2 11.5 total EEr* 2.77 2.80 2.67 2.77
ESEEr 4.73 4.06 4.13 3.86 HEATING CAPACITy KW 17.0 23.6 29.0 33.1
Power input (compressor) kW 4.70 7.14 8.91 10.4 coP* 3.21 3.05 3.05 3.02
Power supply 400V/3+N/50Hz 400V/3+N/50Hz 400V/3+N/50Hz 400V/3+N/50Hz Startup type Direct Direct Direct Direct
REFRIGERANT type R410A
number of refrigerant circuit 1 1 1 1 COMPRESSORS
number 2 2 2 2 type Scroll Scroll Scroll Scroll
EVAPORATOR nombre 1 1 1 1
type Plate Plate Plate Plate COIL
number 1 1 1 1 FANS
number 2 2 2 2 WATER CONNECTIONS
type Male gas threaded inlet/outlet diameter inches 1" 1/2 1" 1/2 1" 1/2 1" 1/2
WEIGHT operating kg 289 307 316 331
DIMENSIONS length mm 1477 1477 1477 1477 Width mm 538 538 538 538
Height mm 1625 1625 1625 1625 ACOUSTICAL DATA (NORMAL MODE)
Sound power level dB(A) 74 75 75 75 Sound pressure level at 10m dB(A) 43 44 44 44
aQh Bln siZes 40 45 50 60 65 75 COOLING CAPACITy KW 36.1 41.0 47.5 55.9 63.3 70.7
input Power (compressor) kW 12.3 14.3 16.7 17.5 20.4 24.6 total EEr* 2.72 2.68 2.69 2.87 2.83 2.66
ESEEr 3.96 3.89 3.92 4.04 4.11 3.77 HEATING CAPACITy KW 39.9 44.4 52.6 59.0 70.0 77.2
HP input Power (compressor) kW 12.0 13.1 14.9 18.9 20.5 24.3 coP* 3.07 3.15 3.31 2.82 3.11 2.94
Power Supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz Startup type irect Direct Direct Direct Direct Direct
aQh eln siZes COOLING CAPACITy KW 36.1 39.5 45.4 54.1 58.8 67.9
input Power (compressor) kW 13.0 15.2 17.9 18.4 21.2 26.2 total EEr* 2.66 2.50 2.46 2.75 2.62 2.47
ESEEr 3.87 3.63 3.59 3.87 3.78 3.53 HEATING CAPACITy KW 40.5 43.5 51.0 57.7 68.2 75.0
HP input Power (compressor) kW 11.9 12.7 15.0 18.8 20.5 24.2 coP* 3.25 3.28 3.28 2.87 3.13 2.94
aQh sif siZes COOLING CAPACITy KW 42.1 46.6 54.3 60.8 66.4 77.0
input Power (compressor) kW 11.7 13.5 15.5 17.7 20.3 24.7 total EEr* 2.93 2.89 2.99 2.98 2.89 2.81
ESEEr 4.33 4.24 4.39 4.27 4.13 3.99 HEATING CAPACITy KW 46.3 50.4 58.7 65.5 77.8 85.9
HP input Power (compressor) kW 13.9 14.8 17.4 19.5 21.3 25.1 coP* 2.80 2.89 2.92 2.96 3.25 3.09
REFRIGERANT type R410A
number of refrigerant circuits 1 1 1 1 1 1 COMPRESSOR
number 2 2 2 2 2 2 type Scroll Scroll Scroll Scroll Scroll Scroll
EVAPORATOR number 1 1 1 1 1 1
type Plate Plate Plate Plate Plate Plate COIL
number 1 1 1 1 1 1 FANS
number 1 1 1 1 1 1 WATER CONNECTIONS (EVAPORATOR)
type Male GAS threaded inlet/outlet diameter inches 2" 2" 2" 2" 2" 2"
WEIGHT operating Weight kg
DIMENSIONS length mm 1750 1750 1750 2200 2200 2200 Width mm 1100 1100 1100 1100 1100 1100
Height mm 1580 1580 1580 1580 1580 1580 ACOUSTICAL DATA (NORMAL MODE)
Sound Power level Bln dB(A) 80.5 81.0 81.0 85.5 85.6 85.8 Sound Pressure level (1) Bln dB(A) 48.9 49.4 49.4 53.8 53.8 54.1
Sound Power level Eln dB(A) 74.0 75.3 75.3 78.0 78.5 79.0 Sound Pressure level (1) Eln dB(A) 42.4 43.7 43.7 46.3 46.8 47.3
Sound Power level SiF*** dB(A) 95.2 95.2 95.2 95.3 95.3 95.3 Sound Pressure level (1) SiF dB(A) 63.6 63.6 63.6 63.6 63.6 63.6
(1) Sound pressure calculated at 10 m. Sound pressure levels refer to ISO standard3744 with parallepiped shape.(*) Gross value According to eurovent standard. (**) Without buffer tank + pumps. (***) Sound data referred to a fan speed of 1110 rpm.
104
Commercial Air Conditioning |
105
AQCL 25-130air-coolEd cHillEr
cooling capacity: from 25 to 125 kW refrigerant: r407c Sizes: 11
MAIN FeATUReS: 2 scroll compressors/1 refrigerant circuit centrifugal Fans
PRODUCT ADVANTAGES Scroll compressors. Brazed stainless steel plate heat exchangers. Microprocessor based iltc control. r407c refrigerant.
compact units taking up the strict minimum of ground surface area, for easy installation. “Plug and Play” design with an integrated hydraulic module for minimising installation costs. accessibility: easy access to all components, thanks to panels removable by screws, thus significantly reducing unit maintenance times.
MAIN OPTIONS & ACCESSORIES anti-vibration pads: rubber anti-vibration pads, to be fitted on site by the installer. anti-vibration mounts: Visible spring anti-vibration mounts, for on site fitting by the installer. compressor jacket: Supplied fitted. condenser coil protective coating:- aluminium fins with hydrophilic coating, - aluminium fins with polyurethane coating. High static motor. remote control terminal: Hard-wired control enabling the unit’s Start/Stop functions to be controlled remotely. low ambient kit (-7°c): Factory-fitted option consists of frequency inverter acting on the motor in order to keep fan speed under control. chiller sequencer: Supplied loose, it allows a control up to 4 units. Water isolating valves: Supplied loose. Water flow switch: Factory-installed option for models 25 to 35. double water pump: Supplied with a control and power supply remote panel. the electrical supply of the latter is to be carried out by others during installation. inlet air duct collar.
Operating limit fOr Standard unitCOOLING MODE
Leaving water temperature without glycol 5/18°C
Outdoor air temperature BLN15/46°C
-7/46°C (with optional fan speed control)
104 105
aQcl siZes 25 30 35 40 50 60 70 80 100 120 130COOLING CAPACITy (1) KW 24.9 28.8 33.7 39.6 46.2 56.3 67.5 76.5 99.1 113.7 124.8
Power input (compressor) kW 11.5 12.9 14.2 16.1 22.0 25.5 28.5 32.0 40.95 44.25 47.95 Power supply 400V/3+N/50Hz
Startup type Direct Direct Direct Direct Direct Direct Direct Direct Direct Direct Direct REFRIGERANT
type R407C number of refrigerant circuit 1 1 1 1 1 1 1 1 1 1 1COMPRESSORS
number 2 2 2 2 2 2 2 2 2 2 2 type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll
EVAPORATOR
nombre 1 1 1 1 1 1 1 1 1 1 1 type Plate Plate Plate Plate Plate Plate Plate Plate Plate Plate Plate
COIL
number 1 1 1 1 1 1 1 1 1 1 1 FANS
number 2 2 2 2 2 2 2 2 2 2 2WATER CONNECTIONS
type Gas threaded inlet/outlet diameter inches 1"1/2 1"1/2 1"1/2 2" 2" 2" 2" 2" 2" 2" 2"
WEIGHT
operating with pump kg 387 405 415 575 630 660 865 920 1010 1080 1130 operating without pump kg 377 395 405 565 620 650 855 910 988 1058 1108
DIMENSIONS
length mm 1752 1752 1752 2206 2206 2206 2464 2464 2464 2464 2464 Width mm 890 890 890 890 890 890 1100 1100 1100 1100 1100
Height mm 1505 1505 1505 1773 1773 1773 2313 2313 2313 2313 2313ACOUSTICAL DATA (NORMAL MODE)
Sound power level dB(A) 81 81 81 80.8 86.1 86.1 83.3 83.3 87.8 87.8 87.8
(1) Values are based on chilled water inlet/outlet temperature of 12/7°C and an outdoor temperature of 35°C.
106
Commercial Air Conditioning |
107
AQCH 25-80air-coolEd HEat PuMP
cooling capacity: from 25 to 80 kW refrigerant: r407c Sizes: 8
MAIN FeATUReS: 2 scroll compressors/1 refrigerant circuit centrifugal Fans
PRODUCT ADVANTAGES Scroll compressors. Brazed stainless steel plate heat exchangers. Microprocessor based iltc control. r407c refrigerant.
compact units taking up the strict minimum of ground surface area, for easy installation. “Plug and Play” design with an integrated hydraulic module for minimising installation costs. accessibility: easy access to all components, thanks to panels removable by screws, thus significantly reducing unit maintenance times.
MAIN OPTIONS & ACCESSORIES anti-vibration pads: rubber anti-vibration pads, to be fitted on site by the installer. anti-vibration mounts: Visible spring anti-vibration mounts, for on site fitting by the installer. compressor jacket: Supplied fitted. condenser coil protective coating:- aluminium fins with hydrophilic coating, - aluminium fins with polyurethane coating. High static motor. remote control terminal: Hard-wired control enabling the unit’s Start/Stop functions to be controlled remotely. low ambient kit (-7°c): Factory-fitted option consists of frequency inverter acting on the motor in order to keep fan speed under control. chiller sequencer: Supplied loose, it allows a control up to 4 units. Water isolating valves: Supplied loose. Water flow switch: Factory-installed option for models 25 to 35. double water pump: Supplied with a control and power supply remote panel. the electrical supply of the latter is to be carried out by others during installation. inlet air duct collar.
Operating limit fOr Standard unitCOOLING MODE
Leaving water temperature without glycol 5/18°C
Outdoor air temperature15/46°C
-7/46°C (with optional fan speed control)
HEATING MODE
Leaving water temperature without glycol 25/50°C
Outdoor air temperature -5/20°C
106 107
aQch siZes 25 30 35 40 50 60 70 80COOLING CAPACITy KW 2.9 28.8 33.7 39.6 46.2 56.3 67.5 76.5
Power input (compressor) kW 11.5 12.9 13.5 16.2 22.0 25.8 28.1 31.6 HEATING CAPACITy KW 27/06/12 32.2 36.3 43.9 55.4 64.2 76.2 84.0
Power input (compressor) kW 11.5 12.9 13.5 16.2 22.0 25.8 28.1 31.6 Power supply 400V/3+N/50Hz
Startup type Direct Direct Direct Direct Direct Direct Direct Direct REFRIGERANT
type R407Cnumber of refrigerant circuit 1 2 3 4 5 6 7 8
COMPRESSORS
number 2 2 2 2 2 2 2 2type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll
EVAPORATOR
nombre 1 1 1 1 1 1 1 1type Plate Plate Plate Plate Plate Plate Plate Plate
COIL
number 1 1 1 1 1 1 1 1FANS
number 2 2 2 2 2 2 2 2WATER CONNECTIONS
type Gas threaded inlet/outlet diameter inches 1"1/2 1"1/2 1"1/2 2" 2" 2" 2" 2"
WEIGHT
operating with pump kg 385 410 425 570 640 660 865 920operating without pump kg 385 410 425 570 640 660 865 920
DIMENSIONS
length mm 1752 1752 1752 2206 2206 2206 2464 2464Width mm 890 890 890 890 890 890 1100 1100
Height mm 1505 1505 1505 1773 1773 1773 2313 2313ACOUSTICAL DATA (NORMAL MODE)
Sound power level dB(A) 81 81 81 80.8 86.1 86.1 83.3 83.3
(1) Values are based on chilled water inlet/outlet temperature of 12/7°C and an outdoor temperature of35°C.
108
Commercial Air Conditioning |
109
AQVSL 85-160air-coolEd cHillEr cooling capacity: from 82 to 157 kW refrigerant: r410a Sizes: 6
MAIN FeATUReS: 2 scroll compressors/1 refrigerant circuit Micro-channel al-al heat exchanger Wide range of hydrokit available
VeRSIONS: Std: Standard Ht: High temperature HPF: High Pressure Fan
ACOUSTIC OPTIONS (FOR STD VeRSION): Bln Basic low noise Eln Extra low noise
PRODUCT ADVANTAGES 1 independant refrigerant circuits. 2 scroll compressors. Standard Microchannel coil. r410a refrigerant. 6 sizes in 3 versions (Std: Standard - Ht: High temperature and HPF: High Pressure Fans). 2 acoustic versions Bln: Basic low noise and Eln: Extra low noise. compact unit. Plug and Play concept: large choice of optional hydrokit kits with or without buffer tank on boars of the chiller.
MAIN OPTIONS ModBus protocol kit for BMS. compressor soft starter. Pressure actuated stepless fan speed controller for low ambient operation (-18°c) (Bln version). double set point. Power factor correction capacitors. Electronic expansion valve. compressor overload protection. automatic circuit breaker. 3 condenser coils with: blue fins, black epoxy treatment,h “Fin guard Silver” (polyurethane) treatment or with copper fins. coil guards and chiller grilles. compressor jacket. desuperheater. on board hydro kits. Electric heaters inside buffer tank to ensure extra heating. automatic pump switch on 2 pump kit. antifreeze electric heater for hydraulic manifolds.
MAIN ACCESSORIES HP & lP monometers. Spring type anti-vibration mounts. remote keyboard panel. Master and slaves control, up to 4 units max. coil guards. chiller grilles. Pressure switch. Water filter.
Operating limit fOr Standard unitCOOLING MODE SizesLeaving water temperature without glycol 5/18°C
Leaving water temperature with glycol
-6/+5°C (with glycol and elec-
tronic expansion valve)+5/+18°C
(standard application)
Outdoor air temperature BLN5/42°C 85-955/45°C 115-160
Outdoor air temperature eLN-18°C to +40°C 85-95-18°C to +42°C 115-160
Outdoor air temperature HT -18°C to +48°CHEATING MODELeaving water temperature 20/50°COutdoor air temperature BLN/HT -10/20°COutdoor air temperature eLN -7/20°C
NOTES Operating limits are referred to full load (2 compressors running).Maximum % glycol (ethylenic or propilenic): 40%.
R410A
108 109
aQvsl size 85 95 115 125 140 160COOLING CAPACITy bLN KW 82.3 94.9 105.8 121.0 134.3 157.2
input power (compressor) kW 24.4 28.4 34.9 39.9 46.5 52.7 total EEr* 3.08 2.98 2.75 2.78 2.68 2.71
ESEEr* 4.31 4.17 3.85 3.90 3.75 3.79 total EEr*/HPF 2.76 2.61 2.63 2.68 2.59 2.59
ESEEr*/HPF 3.87 3.65 3.68 3.75 3.63 3.63 COOLING CAPACITy ELN KW 80.1 92.4 101.9 117.2 129.5 152.2
input power (compressor) kW 25.4 29.7 37.0 41.8 48.7 55.2 total EEr* 2.99 2.90 2.59 2.66 2.54 2.60
ESEEr* 4.18 4.06 3.63 3.72 3.55 3.64 COOLING CAPACITy HT KW 86.1 98.9 108.6 123.6 138.0 160.8
input power (compressor) kW 22.8 26.3 33.4 38.5 44.8 50.9 total EEr* 3.06 2.88 2.80 2.82 2.75 2.73
ESEEr* 4.29 4.04 3.92 3.95 3.86 3.82 Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz
Startup type Direct Direct Direct Direct Direct Direct REFRIGERANT
type R410A number of refrigerant circuits 1 1 1 1 1 1
COMPRESSOR
number 2 2 2 2 2 2type Scroll Scroll Scroll Scroll Scroll Scroll
EVAPORATOR
number 1 1 1 1 1 1 type Plate Plate Plate Plate Plate Plate
COIL
number 2 2 2 2 2 2 FANS
number 2 2 2 2 2 2 WATER CONNECTIONS (EVAPORATOR)
type Victaulicinlet/outlet diameter inches 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2
WATER CONNECTIONS (DESUPERHEATER)
type Male GAS Threaded inlet/outlet diameter inches 1" 1" 1" 1" 1" 1"
WEIGHT
operating weight kg 965 1083 1172 1194 1288 1373 operating weight Eln kg 983 1100 1189 1211 1306 1393
operating weight Ht kg 985 1113 1192 1214 1308 1403 DIMENSIONS
length mm 2950 2950 2950 2950 2950 2950 Width mm 1110 1110 1110 1110 1110 1110
Height mm 2250 2250 2250 2250 2250 2250 ACOUSTIC DATA
Sound power level Bln dB(A) 84 85 88 88 88 90 Sound pressure level (1) dB(A) 52 53 56 56 56 58 Sound power level HPF dB(A) 95 97 95 95 95 97
Sound pressure level HPF (1) dB(A) 63 65 63 63 63 65 Sound power level Eln dB(A) 82 83 84 85 85 87
Sound pressure level (1) Eln dB(A) 50 51 52 53 53 55 Sound power level Ht dB(A) 95 97 95 95 95 97
Sound pressure level (1) Ht dB(A) 63 65 63 63 63 65
(1) Sound pressure calculated at 10 m. Sound pressure levels refer to ISO standard 3744 with parallepiped shape.(*) Gross value According to eurovent standard.
110
Commercial Air Conditioning |
111
AQVSH 85-160air-coolEd cHillEr cooling capacity: from 75 to 152 kW Heating capacity: from 83 to 168 kW refrigerant: r410a Sizes: 6
MAIN FeATUReS: 2 scroll compressors/1 refrigerant circuit Wide range of hydrokit available compact footprint
VeRSIONS: Std: Standard HSE: High Seasonal Efficiency HPF: High Pressure Fan
ACOUSTIC OPTIONS (FOR STD VeRSION): Bln Basic low noise Eln Extra low noise
PRODUCT ADVANTAGES 1 independant refrigerant circuits 2 scroll compressors Standard Microchannel coil r410a refrigerant 6 sizes in 3 versions (Std: Standard- Ht: High temperature and HPF: High Pressure Fans) 2 acoustic versions Bln: Basic low noise and Eln: Extra low noise compact unit Plug and Play concept: large choice of optional hydrokit kits with or without buffer tank on boars of the chiller.
MAIN OPTIONS ModBus protocol kit for BMS. Electronic expansion valve. compressor soft starter. Pressure actuated stepless fan speed controller for low ambient operation (-18°c) (Bln version). double set point. Power factor correction capacitors. compressor overload protection. automatic circuit breaker. condenser coils with: blue fins, black epoxy treatment,h “Fin guard Silver” (polyurethane) treatment or coils with copper fins. coil guards and chiller grilles. compressor jacket. desuperheater. on board hydro kits. automatic pump switch on 2 pump kit. antifreeze electric heater for hydraulic manifolds.
MAIN ACCESSORIES HP & lP monometers. Spring type anti-vibration mounts. remote keyboard panel. Master and slaves control, up to 4 units max. coil guards. chiller grilles. Pressure switch. Water filter.Operating limit fOr Standard unit
COOLING MODE SizesLeaving water temperature without glycol 5/18°C
Leaving water temperature with glycol
-6/+5°C (with glycol and elec-
tronic expansion valve)+5/+18°C
(standard application)
Outdoor air temperature BLN5/48°C 85-955/45°C 115-160
Outdoor air temperature eLN-18°C to +45°C 85-95-18°C to +42°C 115-160
Outdoor air temperature HT-18°C to +50°C 85-95-18°C to +48°C 115-160
NOTES Operating limits are referred to full load (2 compressors running).Maximum % glycol (ethylenic or propilenic): 40%.
R410A
110 111
aQvsh sizes 85 95 115 125 140 160COOLING CAPACITy bLN KW 75.4 85.4 102.6 114.6 132.2 152.4
input power (compressor) kW 26.6 32.0 35.1 41.8 46.5 54.1 total EEr* 2.61 2.41 2.65 2.52 2.64 2.56
ESEEr* 3.65 3.37 3.71 3.53 3.70 3.59 total EEr*/HPF 2.36 2.13 2.53 2.43 2.55 2.45
ESEEr*/HPF 3.31 2.99 3.55 3.40 3.57 3.44 HEATING CAPACITy bLN KW 82.9 96.0 112.2 127.9 143.2 167.6
input power (compressor) kW 24.6 30.1 34.5 39.5 44.3 51.7 total coP* 3.08 2.86 2.94 2.97 2.99 2.94
total coP HPF 2.77 2.52 2.81 2.85 2.89 2.81 COOLING CAPACITy ELN KW 72.8 82.1 98.8 109.7 126.5 145.0
input power (compressor) kW 27.8 33.9 37.3 44.4 49.2 57.8 total EEr* 2.50 2.28 2.50 2.35 2.46 2.37
ESEEr* 3.50 3.19 3.49 3.28 3.44 3.31 HEATING CAPACITy ELN KW 81.0 93.7 109.5 124.4 139.0 161.7
input power (compressor) kW 24.6 30.1 34.5 39.5 44.3 51.6 total coP* 3.12 2.91 2.97 2.98 2.99 2.94
COOLING CAPACITy HT KW 80.5 91.5 105.3 118.1 136.2 157.3
input power (compressor) kW 24.4 28.7 33.7 40.0 44.5 51.7 total EEr* 2.71 2.49 2.70 2.60 2.73 2.63
ESEEr 3.79 3.49 3.78 3.65 3.82 3.69 HEATING CAPACITy HT KW 86.5 100.4 114.0 130.3 147.4 171.3
input power (compressor) kW 24.7 30.1 34.5 39.5 44.2 51.7 total coP* 2.88 2.63 2.86 2.90 2.98 2.87
Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz Startup type Direct Direct Direct Direct Direct Direct
REFRIGERANT
type R410A number of refrigerant circuits 1 1 1 1 1 1
COMPRESSOR
number 2 2 2 2 2 2type Scroll Scroll Scroll Scroll Scroll Scroll
EVAPORATOR
number 1 1 1 1 1 1 type Plate Plate Plate Plate Plate Plate
COIL
number 2 2 2 2 2 2 FANS
number 2 2 2 2 2 2 WATER CONNECTIONS (EVAPORATOR)
type Victaulicinlet/outlet diameter inches 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2
WATER CONNECTIONS (DESUPERHEATER)
type Male GAS Threaded inlet/outlet diameter inches 1" 1" 1" 1" 1" 1"
WEIGHT
operating weight kg 1016 1134 1231 1258 1356 1442 operating weight Eln kg 1034 1152 1248 1276 1374 1462
operating weight Ht kg 1036 1164 1251 1278 1376 1472 DIMENSIONS
length mm 2950 2950 2950 2950 2950 2950 Width (transport only) mm 1110 1110 1110 1110 1110 1110
Height mm 2250 2250 2250 2250 2250 2250 ACOUSTIC DATA
Sound power level Bln dB(A) 84 85 88 88 88 90 Sound pressure level (1) dB(A) 52 53 56 56 56 58 Sound power level HPF dB(A) 95 97 95 95 95 97
Sound pressure level HPF (1) dB(A) 63 65 63 63 63 65 Sound power level Eln dB(A) 82 83 84 85 85 87
Sound pressure level (1) Eln dB(A) 50 51 52 53 53 55 Sound power level Ht dB(A) 95 97 95 95 95 97
Sound pressure level (1) Ht dB(A) 63 65 63 63 63 65 (1) Sound pressure calculated at10 m. Sound pressure levels refer to ISO standard3744 with parallepiped shape.(*) Gross value According to eurovent standard.
112
Commercial Air Conditioning |
113
AQVLair coolEd cHillEr - cooling only
cooling capacity: from 84 to 137 kW aQVl refrigerant: r410a Sizes: 6
VeRSIONS: Std: Standard HSE: High Seasonal Efficiency Ht: High temperature HPF: High Pressure Fan.
ACOUSTIC OPTIONS: Bln Basic low noise ln low noise
PRODUCT ADVANTAGES 4 scroll compressors. 2 independant refrigerant circuits. Bi-flow electronic expansion devices. true dual Plate exchanger. V-shape condenser coils ensuring compactness and small foot print. Standard Microchannel coils. High EEr for fan coil application (water 12/7°c cooling). Excellent EEr for floor application (water 23/18°c cooling). High SEEr. inverter fans for HSE version.
MAIN OPTIONS large choice of optional hydro kits with or without buffer tank fitted on board of the chiller to perform package solution and plug & play concept. HP & lP manometers. compressor soft starter. Power factor correction capacitors. compressor overload protection. automatic circuit breaker. HP & lP manometers. coil guards. chiller grilles. total heat recovery (aQVr). desuperheater. Electric heaters inside buffer tank, used as extra heating. condenser coils treatments. antifreeze electric heater for hydraulic manifolds. different protocol kit for BMS.
MAIN ACCESSORIES Pressure switch. Water filter. chiller grilles. Master and slaves control, up to 4 units max. remote keyboard panel.
Operating limit fOr Standard unitCOOLING MODE
Leaving water temperature without glycol 5/18°C
Leaving water temperature with glycol -8/5°C
Outdoor air temperature BLN 5/48°C
Outdoor air temperature eLN 5/45°C
Outdoor air temperature HSe/HT -18/50°C (48°C size 125 and 140)
NOTES Operating limits are referred to full load (4 compressors running).Maximum % glycol (ethylenic or propilenic): 40%
R410A
112 113
aQvl size 85 95 105 115 125 140 COOLING CAPACITy bLN KW 83.6 93.7 102.8 110.6 122.3 137.1
input power (compressor) kW 24.6 28.5 31.1 33.9 37.2 42.1 total EEr* 3.13 3.07 3.10 3.08 3.01 3.01
ESEEr* 4.39 4.29 4.34 4.31 4.22 4.22 total EEr*/HSE 3.24 3.16 3.19 3.15 3.09 3.08
ESEEr*/HSE 4.77 4.64 4.69 4.64 4.54 4.53 total EEr*/HPF 2.97 2.92 2.97 2.95 2.93 2.94
ESEEr*/HPF 4.15 4.09 4.15 4.13 4.10 4.11 COOLING CAPACITy ELN KW 80.9 90.3 98.7 105.8 119.5 133.6
input power (compressor) kW 26.0 30.4 33.3 36.4 38.6 43.9 total EEr* 2.91 2.80 2.81 2.77 2.93 2.91
ESEEr* 4.07 3.93 3.94 3.88 4.11 4.07 total EEr*/Eln HSE 3.04 2.91 2.91 2.86 3.00 2.96
ESEEr*/Eln HSE 4.46 4.28 4.28 4.20 4.41 4.36 COOLING CAPACITy HT KW 86.2 97.0 106.9 115.3 124.6 139.6
input power (compressor) kW 23.2 26.6 28.9 31.4 36.1 40.9 total EEr* 3.10 3.10 3.19 3.21 3.06 3.07
ESEEr 4.34 4.34 4.46 4.49 4.29 4.30 Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz
Startup type Direct Direct Direct Direct Direct Direct REFRIGERANT
type R410A number of refrigerant circuits 2 2 2 2 2 2
COMPRESSOR
number 4 4 4 4 4 4 type Scroll Scroll Scroll Scroll Scroll Scroll
EVAPORATOR
number 1 1 1 1 1 1 type Plate Plate Plate Plate Plate Plate
COIL
number 2 2 2 2 2 2 FANS
number 2 2 2 2 2 2 WATER CONNECTIONS (EVAPORATOR)
type Male GAS Threaded inlet/outlet diameter inches 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2
WATER CONNECTIONS (DESUPERHEATER)
type Male GAS Threaded inlet/outlet diameter inches 1" 1" 1" 1" 1" 1"
WEIGHT
operating weight kg 1058 1072 1111 1143 1183 1262 operating weight Eln kg 1088 1102 1141 1173 1213 1292
DIMENSIONS
length mm 2555 2555 2555 2555 3155 3155 Width mm 1095 1095 1095 1095 1095 1095
Height mm 2185 2185 2185 2185 2185 2185 ACOUSTIC DATA
Sound power level Bln dB(A) 85 85 85 85 89 89 Sound pressure level (1) dB(A) 53 53 53 53 57 57 Sound power level HPF dB(A) 92 92 92 92 95 95
Sound pressure level HPF (1) dB(A) 60 60 60 60 63 63 Sound power level Eln dB(A) 82 82 82 82 86 86
Sound pressure level (1) Eln dB(A) 50 50 50 50 54 54 Sound power level Ht dB(A) 95 95 95 95 95 95
Sound pressure level (1) Ht dB(A) 63 63 63 63 63 63
(1) Sound pressure calculated at 10 m. Sound pressure levels refer to ISO standard 3744 with parallepiped shape.(*) Gross value According to eurovent standard.
114
Commercial Air Conditioning |
115
AQVHWatEr coolEd HEat PuMP rEVErSiBlE
cooling capacity: from 80 to 130 kW aQVl Heating capacity: from 92 to 146 kW aQVl refrigerant: r410a Sizes: 6
VeRSIONS: Std: Standard HSE: High Seasonal Efficiency Ht: High temperature HPF: High Pressure Fan
ACOUSTIC OPTIONS: Bln Basic low noise Eln Extra low noise
PRODUCT ADVANTAGES 4 scroll compressors. 2 independant refrigerant circuits. Bi-flow electronic expansion devices. true dual Plate exchanger. V-shape condenser coils ensuring compactness and small foot print. Blue fins Microchannel coils. High EEr and coP for fan coil application (water 12/7°c cooling, 40/45°c heating). Excellent EEr and coP for floor heating application (water 23/18°c cooling, 30/35°c heating). High SEEr. inverter fans for HSE version.
MAIN OPTIONS large choice of optional hydro kits with or without buffer tank fitted on board of the chiller to perform package solution and plug & play concept. HP & lP manometers. compressor soft starter. Power factor correction capacitors. compressor overload protection. HP & lP manometers. coil guards. chiller grilles. total heat recovery (aQVr). desuperheater. Electric heaters inside buffer tank, used as extra heating. condenser coils treatments. antifreeze electric heater for hydraulic manifolds. different protocol kit for BMS.
MAIN ACCESSORIES Pressure switch. Water filter. chiller grilles. Master and slaves control, up to 4 units max. remote keyboard panel.
Operating limit fOr Standard unitCOOLING MODE
Leaving water temperature without glycol 5/18°C
Leaving water temperature with glycol -8/5°C
Outdoor air temperature BLN 5/48°C
Outdoor air temperature eLN 5/45°C
Outdoor air temperature HSe/HT -18/50°C (48°C size 125 and 140)
HEATING MODE
Leaving water temperature 20/55°C
Outdoor air temperature BLN/HSe -15/20°C
Outdoor air temperature eLN -14/20°C
NOTES Operating limits are referred to full load (4 compressors running).Maximum % glycol (ethylenic or propilenic): 40%.
R410A
114 115
aQvh sizes std/hse/hpf - Bln version 85 95 105 115 125 140 COOLING CAPACITy bLN KW 81.2 90.2 99.2 107.2 116.2 129.6
input power (compressor) kW 25.1 29.1 31.8 34.5 38.0 42.6 total EEr* 2.99 2.89 2.93 2.93 2.80 2.82
ESEEr* 4.18 4.04 4.10 4.10 3.93 3.95 total EEr*/HSE 3.09 2.97 3.01 3.00 2.87 2.88
ESEEr*/HSE 4.54 4.37 4.42 4.41 4.22 4.23 total EEr*/HPF 2.83 2.76 2.80 2.81 2.73 2.75
ESEEr*/HPF 3.96 3.86 3.93 3.94 3.82 3.84 HEATING CAPACITy bLN KW 91.5 102.4 110.7 118.6 133.9 146.3
input power (compressor) kW 24.4 28.0 30.0 32.7 37.1 40.8 total coP* 3.45 3.40 3.45 3.41 3.31 3.31
total coP HSE 3.57 3.50 3.55 3.50 3.39 3.39 total coP HPF 3.27 3.24 3.30 3.27 3.21 3.22
COOLING CAPACITy ELN KW 78.5 86.8 95.1 102.5 112.5 125.0 input power (compressor) kW 26.6 31.2 34.1 37.1 40.8 45.1
total EEr* 2.76 2.63 2.65 2.64 2.62 2.65 ESEEr* 3.87 3.69 3.71 3.69 3.67 3.71
total EEr*/HSE 2.88 2.73 2.74 2.72 2.68 2.70 ESEEr*/HSE 4.24 4.02 4.03 4.00 3.94 3.97
HEATING CAPACITy ELN KW 89.5 99.9 107.8 115.3 129.4 142.0 input power (compressor) kW 24.4 28.0 29.9 32.6 36.8 40.4
total coP* 3.42 3.35 3.40 3.35 3.33 3.34 total coP HSE 3.59 3.50 3.53 3.47 3.41 3.41
COOLING CAPACITy HT KW 83.6 93.4 103.8 111.7 118.0 132.1 input power (compressor) kW 23.6 27.2 29.5 32.0 37.0 41.2
total EEr* 2.96 2.94 3.04 3.05 2.83 2.88 ESEEr 4.14 4.12 4.25 4.27 3.97 4.03
HEATING CAPACITy HT KW 93.5 104.9 113.7 121.9 135.6 148.3 input power (compressor) kW 24.5 28.1 30.1 32.8 37.2 40.9
total coP* 3.22 3.21 3.28 3.26 3.25 3.26 Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz
Startup type Direct Direct Direct Direct Direct Direct REFRIGERANT
type R410A number of refrigerant circuits 2 2 2 2 2 2
COMPRESSOR number 4 4 4 4 4 4
type Scroll Scroll Scroll Scroll Scroll Scroll EVAPORATOR
number 1 1 1 1 1 1 type Plate Plate Plate Plate Plate Plate
COIL number 2 2 2 2 2 2
FANS number 2 2 2 2 2 2
WATER CONNECTIONS (EVAPORATOR) type Male GAS Threaded
inlet/outlet diameter inches 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 WATER CONNECTIONS (DESUPERHEATER)
type Male GAS Threaded inlet/outlet diameter inches 1" 1" 1" 1" 1" 1"
WEIGHT operating weight kg 1090 1105 1149 1180 1227 1301
operating weight Eln kg 1120 1135 1179 1210 1257 1331 DIMENSIONS
length mm 2555 2555 2555 2555 3155 3155 Width mm 1095 1095 1095 1095 1095 1095
Height mm 2185 2185 2185 2185 2185 2185 ACOUSTIC DATA
Sound power level Bln dB(A) 85 85 85 85 89 89 Sound pressure level (1) dB(A) 53 53 53 53 57 57 Sound power level HPF dB(A) 92 92 92 92 95 95
Sound pressure level HPF (1) dB(A) 60 60 60 60 63 63 Sound power level Eln dB(A) 82 82 82 82 86 86
Sound pressure level (1) Eln dB(A) 50 50 50 50 54 54 Sound power level Ht dB(A) 95 95 95 95 95 95
Sound pressure level (1) Ht dB(A) 63 63 63 63 63 63
(1) Sound pressure calculated at10 m. Sound pressure levels refer to ISO standard3744 with parallepiped shape.(*) Gross value According to eurovent standard.
116
Commercial Air Conditioning |
117
VLS 524-1204air-coolEd cHillEr cooling capacity: from 137 to 308 kW refrigerant: r410a Sizes: 8
MAIN FeATUReS: 4 scroll compressors/2 independent refrigerant circuits
true-dual plate heat exchanger Wide range of hydrokit available
VeRSIONS: Std: Standard HSE: High Seasonal Efficiency Ht: High temperature HPF: High Pressure Fans
ACOUSTIC OPTIONS (FOR STD AND HSe VeRSIONS): Bln Basic low noise ln low noise Eln Extra low noise
PRODUCT ADVANTAGES 2 independant refrigerant circuits. 4 scroll compressors. r410a refrigerant. Bi-flow electronic expansion devices. Easy upgrade of the units in stock or on the field. “true dual” two-circuit plate heat exchanger. large choice of configurations: 4 versions and 3 acoustic option with largec choice of accessories. Ec fans for Hight Seasonal Efficiency version, High temperature and High Pressure Fans.
MAIN OPTIONS ModBus, lonwork, Bacner protocol kit for BMS. compressors soft starter. Pressure actuated stepless fan speed controller for low ambient operation (-18°c). double set point (VlS only). Power factor correction capacitors. compressors overload protection. gSM. HP & lP manometers. condenser coils with blue fins treatment, “Fin guard Silver” (polyurethane) treatment or copper fins. chiller grilles. 2 heat recovery options: total heat recovery (Vlr) and desuperheater. on board hydro kits without buffer tank (VlS/VlH only). on board hydro kits with 500 litres buffer tank with or without pumps.
MAIN ACCESSORIES remote on/oFF control. remote keyboard panel. Master and slaves control, up to 4 units max. Spring anti-vibration. Flow switch. Water filter. remote hydro kits with buffer tank, 1 or 2 low or high pressure pump(s), relevant accessories and with or without antifreeze heater.
Operating limit fOr Standard unitCOOLING MODE SizesLeaving water temperature without glycol 6/15°CLeaving water temperature with glycol -8/15°C
Outdoor air temperature BLN
0/46°C 524-804-1004-5/47°C 604-7040/47°C 9040/45°C 1104-1204
Outdoor air temperature LN/eLN
0/44°C 524-804-1004-5/45°C 604-7040/45°C 9040/42°C 1104-1204
Outdoor air temperature HT-18/48°C 524-804-1004-18/49°C 604-704-904-18/47°C 1104-1204
NOTES Operating limits are referred to full load (4 compressors running).Maximum % glycol (ethylenic or propilenic): 40%
R410A
116 117
vls 524 604 704 804 904 1004 1104 1204COOLING CAPACITy STD/HSE/HPF bLN (1) KW 136.6 154.3 176.9 198.8 228.9 250.9 279.6 307.7
input power (compressor) kW 45.0 49.7 59.4 65.5 74.6 78.5 91.6 106.2 total EEr* 2.80 2.79 2.72 2.79 2.78 2.91 2.82 2.70
ESEEr* 3.79 3.77 3.68 3.78 3.77 3.94 3.81 3.66 total EEr*/HSE 2.87 2.87 2.79 2.86 2.86 2.99 2.89 2.76
ESEEr*/HSE 4.36 4.37 4.24 4.35 4.36 4.55 4.39 4.20 COOLING CAPACITy STD/HSE LN (1) 132.2 149.8 172.2 193.1 222.8 241.6 267.2 292.8
input power (compressor) 47.3 52.1 62.2 68.9 78.4 83.1 98.2 114.5 total EEr* 2.66 2.69 2.62 2.66 2.68 2.75 2.59 2.45
ESEEr* 3.90 3.94 3.84 3.90 3.93 4.03 3.80 3.60 total EEr*/ln HSE 2.72 2.78 2.69 2.73 2.75 2.82 2.65 2.50
ESEEr*/ln HSE 4.30 4.38 4.24 4.31 4.35 4.45 4.19 3.95 COOLING CAPACITy STD/HSE ELN (1) KW 127.7 146.0 167.2 186.8 216.7 234.7 258.8 282.9
input power (compressor) kW 49.7 54.2 65.1 72.4 81.8 86.6 102.6 120.0 total EEr* 2.47 2.55 2.46 2.48 2.53 2.59 2.43 2.28
ESEEr* 3.85 3.98 3.83 3.86 3.94 4.04 3.78 3.56 total EEr*/Eln HSE 2.54 2.65 2.53 2.55 2.61 2.67 2.49 2.33
ESEEr*/Eln HSE 4.21 4.39 4.20 4.23 4.33 4.43 4.14 3.87 COOLING CAPACITy HT (1) KW 138.1 156.1 178.6 200.9 231.7 254.2 282.4 313.3
input power (compressor) kW 44.2 48.7 58.4 64.4 73.2 76.8 89.9 103.1 total EEr* 2.84 2.79 2.74 2.82 2.80 2.93 2.83 2.77
Power supply 400V/3/50Hz Startup type Direct Direct Direct Direct Direct Direct Direct Direct
REFRIGERANT
type R410A number of refrigerant circuits 2 2 2 2 2 2 2 2
COMPRESSOR
number 4 4 4 4 4 4 4 4 type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll
EVAPORATOR
number 1 1 1 1 1 1 1 1 type Plate Plate Plate Plate Plate Plate Plate Plate
COIL
number 2 2 2 2 2 2 2 2 FANS
number 2 3 3 3 4 4 4 4WATER CONNECTIONS (EVAPORATOR)
type Male GAS Threaded inlet/outlet diameter inches 2"1/2 2"1/2 2"1/2 2"1/2 3" 3" 3" 3"
WATER CONNECTIONS (DESUPERHEATER)
type Male GAS Threaded inlet/outlet diameter inches 1" 1" 1" 1" 1" 1" 1" 1"
WEIGHT
operating weight Bln ln kg 1200 1425 1615 1760 1905 2035 2125 2135 operating weight Eln kg 1230 1460 1650 1795 1940 2075 2165 2175
operating weight Ht kg 1230 1455 1645 1790 1945 2075 2165 2175 DIMENSIONS**
length mm 3300 3300 4300 4300 4300 4300 4300 4300 Width mm 1100 1100 1100 1100 1100 1100 1100 1100
Height mm 2300 2300 2300 2300 2300 2300 2300 2300 ACOUSTIC DATA
Sound power level Bln (3) dB(A) 92 93 93 93 94 94 95 95 Sound pressure level (4) dB(A) 60 61 61 61 62 62 63 63
Sound power level ln (3) dB(A) 86 87 87 87 88 88 89 89 Sound pressure level ln (4) dB(A) 54 55 55 55 56 56 57 57 Sound power level Eln (3) dB(A) 83 83 83 83 84 84 85 85
Sound pressure level Eln (4) dB(A) 51 51 51 51 52 52 53 53 Sound power level Ht (3) dB(A) 97 99 99 99 100 100 100 100
Sound pressure level Ht (4) dB(A) 65 67 67 67 68 68 68 68
(*) Gross value According to eurovent standard.(**) Dimension without hydrokit.(1) Data based on 7°C leaving chilled water temperature and 35°C ambient air temperature.(3) Sound levels are at fully loaded conditions. Sound power level values refer to ISO standard 3744 and eurovent 8/1.(4) Sound pressure level values refer to ISO standard 3744, parallelepiped shape.
118
Commercial Air Conditioning |
119
VLH 524-1204air-to-WatEr HEat PuMP cooling capacity: from 134 to 301 kW Heating capacity: from 150 to 336 kW refrigerant: r410a Sizes: 8
MAIN FeATUReS: 4 scroll compressors/2 independent refrigerant circuits
true-dual plate heat exchanger Wide range of hydrokit available
VeRSIONS: Std: Standard HSE: High Seasonal Efficiency Ht: High temperature HPF: High pressure Fans
ACOUSTIC OPTIONS (FOR STD AND HSe VeRSIONS): Bln Basic low noise ln low noise Eln Extra low noise
PRODUCT ADVANTAGES 2 independant refrigerant circuits. 4 scroll compressors. r410a refrigerant. Bi-flow electronic expansion devices. Easy upgrade of the units in stock or on the field. “true dual” two-circuit plate heat exchanger. large choice of configurations: 4 versions and 3 acoustic option with largec choice of accessories. Ec fans for Hight Seasonal Efficiency version, High temperature and High Pressure Fans.
MAIN OPTIONS ModBus, lonwork, Bacner protocol kit for BMS. compressors soft starter. Pressure actuated stepless fan speed controller for low ambient operation (-18°c). double set point (VlS only). Power factor correction capacitors. compressors overload protection. gSM. HP & lP manometers. condenser coils with blue fins treatment, “Fin guard Silver” (polyurethane) treatment or copper fins. chiller grilles. 2 heat recovery options: total heat recovery (Vlr) and desuperheater. on board hydro kits without buffer tank (VlS/VlH only). on board hydro kits with 500 litres buffer tank with or without pumps.
MAIN ACCESSORIES remote on/oFF control. remote keyboard panel. Master and slaves control, up to 4 units max. Spring anti-vibration. Flow switch. Water filter. remote hydro kits with buffer tank, 1 or 2 low or high pressure pump(s), relevant accessories and with or without antifreeze heater.
Operating limit fOr Standard unitCOOLING MODE SizesLeaving water temperature without glycol 6/18°CLeaving water temperature with glycol -8/15°C
Outdoor air temperature BLN
0/46°C 524-804-1004-5/47°C 604-7040/47°C 9040/45°C 1104-1204
Outdoor air temperature LN/eLN
0/44°C 524-804-1004-5/45°C 604-7040/45°C 9040/42°C 1104-1204
Outdoor air temperature HT-18/48°C 524-804-1004-18/49°C 604-704-904-18/47°C 1104-1204
HEATING MODELeaving water temperature 30/50°COutdoor air temperature* -10/20°C
*Max. leaving water temperature = 40°C at -10°C in fully loaded conditions and leaving water temperature = 45°C in part loaded conditions.
NOTES Operating limits are referred to full load (2 compressors running).Maximum % glycol (ethylenic or propilenic): 40%.
R410A
118 119
vlh 524 604 704 804 904 1004 1104 1204COOLING CAPACITy STD/HSE/HPF bLN (1) KW 134.2 150.1 174.0 197.6 226.7 246.8 273.9 300.5
input power (compressor) kW 45.0 50.2 59.4 65.5 74.2 78.4 91.3 105.7 total EEr* 2.75 2.69 2.67 2.78 2.77 2.87 2.77 2.65
ESEEr* 3.72 3.63 3.62 3.75 3.75 3.88 3.75 3.59 total EEr*/HSE 2.82 2.77 2.74 2.84 2.85 2.95 2.84 2.71
ESEEr*/HSE 4.29 4.21 4.17 4.32 4.34 4.48 4.31 4.12 HEATING CAPACITy bLN (2) KW 149.6 169.0 199.2 234.9 254.1 272.5 300.8 335.8
input power (compressor) kW 44.7 51.3 60.6 69.8 71.4 79.3 91.3 103.4 total coP* 3.08 2.96 3.00 3.11 3.22 3.14 3.04 3.03
total coP*HSE 3.16 3.06 3.08 3.18 3.31 3.22 3.11 3.09COOLING CAPACITy STD/HSE LN (1) 130 146 169 192 221 238 262 286
input power (compressor) 47 53 62 69 78 83 98 114total EEr* 2.62 2.60 2.58 2.65 2.66 2.71 2.56 2.41
ESEEr* 3.83 3.81 3.78 3.88 3.90 3.98 3.75 3.54total EEr*/ln HSE 2.68 2.68 2.64 2.71 2.74 2.78 2.62 2.46
ESEEr*/ln HSE 4.23 4.23 4.17 4.28 4.32 4.39 4.13 3.88HEATING CAPACITy STD/HSE LN 145.6 164.5 194.2 215.6 246.5 262.1 287.6 320.7
input power (compressor) 44.6 51.4 60.6 63.3 71.2 79.1 91.2 103.3total coP* 3.10 2.99 3.02 3.22 3.24 3.12 3.00 2.97
total coP*HSE 3.18 3.09 3.11 3.31 3.35 3.21 3.07 3.03COOLING CAPACITy STD/HSE ELN (1) KW 125.6 142.2 164.6 185.7 214.8 231.0 254.1 276.7
input power (compressor) kW 49.7 54.6 64.9 72.3 81.6 86.3 102.2 119.4total EEr* 2.4 2.5 2.4 2.5 2.5 2.6 2.4 2.2
ESEEr* 3.8 3.8 3.8 3.8 3.9 4.0 3.7 3.5total EEr*/Eln HSE 2.5 2.6 2.5 2.5 2.6 2.6 2.5 2.3
ESEEr*/Eln HSE 4.1 4.2 4.1 4.2 4.3 4.4 4.1 3.8HEATING CAPACITy STD/HSE ELN (1) KW 137.1 156.4 183.7 202.4 232.4 244.5 266.3 296.0
input power (compressor) kW 44.6 51.5 60.7 63.1 71.1 78.8 90.1 103.1total coP* 2.9 2.9 2.9 3.1 3.1 3.0 2.8 2.8
total coP*HSE 3.0 3.0 3.0 3.2 3.2 3.1 2.9 2.8COOLING CAPACITy HT KW 135.8 151.7 175.6 199.7 229.5 250.1 276.5 305.6
input power (compressor) kW 44.2 49.2 58.4 64.4 73.2 76.8 89.9 102.8total EEr* 2.8 2.7 2.7 2.8 2.8 2.9 2.8 2.7
HEATING CAPACITy HT KW 150.9 170.5 200.7 224.0 256.6 273.7 305.5 341.5input power (compressor) kW 44.6 51.3 60.6 63.5 71.4 79.3 91.4 103.5
total coP* 3.1 2.9 3.0 3.2 3.2 3.1 3.0 3.0Power supply 400V/3/50Hz
Startup type Direct Direct Direct Direct Direct Direct Direct Direct REFRIGERANT
type R410A number of refrigerant circuits 2 2 2 2 2 2 2 2
COMPRESSOR number 4 4 4 4 4 4 4 4
type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll EVAPORATOR
number 1 1 1 1 1 1 1 1type Plate Plate Plate Plate Plate Plate Plate Plate
COIL number 2 2 2 2 2 2 3 4
FANS number 2 3 3 3 4 4 4 4
WATER CONNECTIONS (EVAPORATOR) type Male GAS Threaded
inlet/outlet diameter inches 2"1/2 2"1/2 2"1/2 2"1/2 3" 3" 3" 3"WATER CONNECTIONS (DESUPERHEATER)
type Male GAS Threaded inlet/outlet diameter inches 1" 1" 1" 1" 1" 1" 1" 1"
WEIGHT operating weight Bln/ln kg 1260 1485 1675 1820 1980 2125 2215 2225
operating weight Eln kg 1290 1520 1710 1855 2015 2165 2255 2265 operating weight Ht kg 1290 1515 1705 1850 2020 2165 2255 2265
DIMENSIONS** length mm 3300 3300 4300 4300 4300 4300 4300 4300 Width mm 1100 1100 1100 1100 1100 1100 1100 1100
Height mm 2300 2300 2300 2300 2300 2300 2300 2300 ACOUSTIC DATA
Sound power level Bln (3) dB(A) 92 93 93 93 94 94 95 95 Sound pressure level (4) dB(A) 60 61 61 61 62 62 63 63
Sound power level ln (3) dB(A) 86 87 87 87 88 88 89 89 Sound pressure level (4) dB(A) 54 55 55 55 56 56 57 57
Sound power level Eln (3) dB(A) 83 83 83 83 84 84 85 85 Sound pressure level (4) Eln dB(A) 51 51 51 51 52 52 53 53
Sound power level Ht (3) dB(A) 97 99 99 99 100 100 100 100 Sound pressure level (4) Ht dB(A) 65 67 67 67 68 68 68 68
(*) Gross value According to eurovent standard. (**) Dimension without hydrokit.(1) Data based on 7°C leaving chilled water temperature and 35°C ambient air temperature.(2) Data based on 45°C leaving hot water temperature and 7°C ambient air temperature with 88 % relative humidity.(3) Sound levels are at fully loaded conditions. Sound power level values refer to ISO standard 3744 and eurovent 8/1.(4) Sound pressure level values refer to ISO standard 3744, parallelepiped shape.
120
Commercial Air Conditioning |
121
AQWL 1404-2406air-coolEd cHillEr cooling capacity: from 380 to 634 kW refrigerant: r410a Sizes: 5
MAIN FeATUReS: 4 or 6 scroll compressors/2 independent refrigerant circuits true-dual plate heat exchanger
total heat recovery (aQWr models) Wide range of hydrokit available
VeRSIONS: Std: Standard HSE: High Seasonal Efficiency Ht: High temperature HPF: High Pressure Fan
ACOUSTIC OPTIONS (STD AND HSe ONLY): Bln Basic low noise ln low noise Eln Extra low noise
PRODUCT ADVANTAGES 2 independant refrigerant circuits. 4/6 scroll compressors. r410a refrigerant. Bi-flow electronic expansion devices. “Slim and light” structure. Easy upgrade of the units in stock or on the field. “true dual” two-circuit plate heat exchanger. new position for electrical box. large choice of configurations: 4 versions and 3 acoustic option with largec choice of accessories. Ec fans for Hight Seasonal Efficiency version, High temperature and High Pressure Fans. Standard coils in al/cu, arranged in V configurations to get a better air distribution and than optimize its performance.
MAIN ACCESSORIES remote on/oFF control. remote keyboard panel. Master and slaves control, up to 4 units max. chiller grilles. Spring anti-vibration Flow switch. Pressure switch. Water filter. remote hydro kits with buffer tank, 1 or 2 low or high pressure pump(s), relevant accessories and with or without tank antifreeze heater.
Operating limit fOr Standard unitCOOLING MODE SizesLeaving water temperature without glycol 6/15°CLeaving water temperature with glycol -8/15°C
Outdoor air temperature BLN-5/44°C 14040/44°C 1604-2406
Outdoor air temperature LN-5/42°C 14040/42°C 1604-2406
Outdoor air temperature eLN -18/40°COutdoor air temperature HT* -18/45°C
*Max. ambient air temperature of +48°C in part loaded conditions.
NOTES Operating limits are referred to full load (4 compressors running).Maximum % glycol (ethylenic or propilenic): 40%.
MAIN OPTIONS ModBus, lonwork or Bacner protocol kit for BMS. WEBctrl. Ethernet tcP/iP interface board. compressors soft starter. Pressure actuated stepless fan speed controller for low ambient operation (-18°c) (Bln & ln versions). Power factor correction capacitors. compressors overload protection. gSM. HP & lP manometers. condenser coils with blue fins treatment, “Fin guard Silver” (polyurethane) treatment or copper fins. High static pressure fans (ESP<120 Pa) for HPF version. coil guards and chiller grilles. compressor jacket. Water pump acoustic box. total heat recovery (aQWr) and desuperheater. on board hydro kits with or without buffer tank (750 or 1000 litres), 1 or 2 low or high pressure pump(s) and relevant accessories. on board hydro kits with buffer tank (750 or 1000 litres) alone, without pumps.
R410A
120 121
aQwl 1404 1604 1806 2106 2406COOLING CAPACITy STD/HSE/HPF bLN (1) KW 380.0 422.9 496.0 562.0 634.4
input power (compressor) kW 116.6 131.2 153.0 174.9 196.8 total EEr* 2.90 2.90 2.90 2.91 2.90
ESEEr* 4.07 4.08 4.07 4.09 4.08 total EEr*/HSE 2.93 2.93 2.93 2.94 2.93
ESEEr*/HSE 4.22 4.22 4.22 4.23 4.22 COOLING CAPACITy STD/HSE LN (1) 368.2 410.3 481.0 544.0 615.4
input power (compressor) 122.0 137.0 160.0 182.0 205.0 total EEr* 2.80 2.80 2.80 2.80 2.80
ESEEr* 4.08 4.08 4.08 4.09 4.09 total EEr*/ln HSE 2.86 2.86 2.86 2.86 2.86
ESEEr*/ln HSE 4.28 4.27 4.27 4.27 4.28 COOLING CAPACITy STD/HSE ELN (1) KW 349.8 389.0 456.5 517.2 584.0
input power (compressor) kW 129.4 145.2 170.4 194.1 217.8 total EEr* 2.52 2.51 2.50 2.51 2.52
ESEEr* 3.81 3.80 3.78 3.79 3.80 total EEr*/Eln HSE 2.65 2.63 2.63 2.62 2.64
ESEEr*/Eln HSE 4.10 4.07 4.07 4.06 4.08 COOLING CAPACITy HT (1) KW 383.8 427.1 501.0 567.6 640.7
input power (compressor) kW 115.4 129.9 151.5 173.2 194.8 total EEr* 2.82 2.83 2.82 2.85 2.83
Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz Startup type Direct Direct Direct Direct Direct
REFRIGERANT
type R410A number of refrigerant circuits 2 2 2 2 2
COMPRESSOR
number 4 4 6 6 6type Scroll Scroll Scroll Scroll Scroll
EVAPORATOR
number 1 1 1 1 1 type Plate Plate Plate Plate Plate
COIL
number 4 4 4 4 4FANS
number 8 8 10 10 12WATER CONNECTIONS (EVAPORATOR)
type Victaulicinlet/outlet diameter inches 4" 4" 4" 4" 4"
WATER CONNECTIONS (DESUPERHEATER)
type Male GAS Threaded inlet/outlet diameter inches 2" 2" 2" 2" 2"
WEIGHT
operating weight kg 2668 2887 3599 3854 3975 DIMENSIONS**
length mm 4000 4000 5000 6000 6000 Width mm 2200 2200 2200 2200 2200
Height mm 2550 2550 2550 2550 2550 ACOUSTIC DATA
Sound power level Bln (3) dB(A) 97 97 98 98 99 Sound pressure level (4) dB(A) 65 65 66 66 67
Sound power level ln (3) dB(A) 91 91 92 92 93 Sound pressure level ln (4) dB(A) 59 59 60 60 61 Sound power level Eln (3) dB(A) 88 88 89 89 90
Sound pressure level Eln (4) dB(A) 56 56 57 57 58 Sound power level Ht (3) dB(A) 103 103 104 104 105
Sound pressure level Ht (4) dB(A) 71 71 72 72 73
(*) Gross value According to eurovent standard.(**)Dimension without hydrokit.(1)Data based on7°C leaving chilled water temperature and35°C ambient air temperature.(3) Sound levels are at fully loaded conditions. Sound power level values refer to ISO standard3744 and eurovent8/1.(4) Sound pressure level values refer to ISO standard3744. parallelepiped shape.
122
Commercial Air Conditioning |
123
AQWH 1404-2406air-to-WatEr HEat PuMP cooling capacity: from 360 to 602 kW Heating capacity: from 418 to 702 kW refrigerant: r410a Sizes: 5/3-phase
MAIN FeATUReS: 4 or 6 scroll compressors/2 independent refrigerant circuits
true-dual plate heat exchanger optional desuperheater for 20% partial heat recovery Wide range of hydrokit available
VeRSIONS: Std: Standard HSE: High Seasonal Efficiency Ht: High temperature HPF: High Pressure Fan
ACOUSTIC OPTIONS (STD AND HSe ONLY): Bln Basic low noise ln low noise Eln Extra low noise
PRODUCT ADVANTAGES 2 independant refrigerant circuits. 4/6 scroll compressors. r410a refrigerant. Bi-flow electronic expansion devices. “Slim and light” structure. new position for electrical box. Easy upgrade of the units in stock or on the field. “true dual” two-circuit plate heat exchanger. large choice of configurations: 4 versions and 3 acoustic option with largec choice of accessories. Ec fans for Hight Seasonal Efficiency version, High temperature and High Pressure Fans. Standard coils in al/cu, arranged in V configurations to get a better air distribution and than optimize its performance.
Operating limit fOr Standard unitCOOLING MODE SizesLeaving water temperature without glycol 6/15°CLeaving water temperature with glycol -8/15°C
Outdoor air temperature BLN-5/44°C 14040/44°C 1604-2406
Outdoor air temperature LN-5/42°C 14040/42°C 1604-2406
Outdoor air temperature eLN -18/40°COutdoor air temperature HT* -18/45°C
*Max. ambient air temperature of +48°C in part loaded conditions.
HEATING MODE SizesLeaving water temperature 30/50°COutdoor air temperature* -10/20°C
*Max. leaving water temperature = 40°C at -10°C in fully loaded conditions and leaving water temperature = 45°C in part loaded conditions.
NOTES Operating limits are referred to full load (2 compressors running).Maximum % glycol (ethylenic or propilenic): 40%
MAIN OPTIONS ModBus, lonwork, Bacner protocol kit for BMS. compressors soft starter. Pressure actuated stepless fan speed controller for low ambient operation (-18°c). double set point (VlS only). Power factor correction capacitors. compressors overload protection. gSM. HP & lP manometers. condenser coils with blue fins treatment, “Fin guard Silver” (polyurethane) treatment or copper fins. chiller grilles. 2 heat recovery options: total heat recovery (Vlr) and desuperheater. on board hydro kits without buffer tank (VlS/VlH only). on board hydro kits with 500 litres buffer tank with or without pumps.
MAIN ACCESSORIES remote on/oFF control. remote keyboard panel. Master and slaves control, up to 4 units max. Spring anti-vibration. Flow switch. Water filter. remote hydro kits with buffer tank, 1 or 2 low or high pressure pump(s), relevant accessories and with or without antifreeze heater.
R410A
122 123
aQwh 1404 1604 1806 2106 2406COOLING CAPACITy STD/HSE/HPF bLN (1) KW 360.2 401.7 472.2 537.0 601.9
input power (compressor) kW 119.0 134.0 156.0 178.5 201.0 total EEr* 2.77 2.71 2.77 2.71 2.70
ESEEr* 3.90 3.80 3.89 3.80 3.80 total EEr*/HSE 2.80 2.73 2.79 2.73 2.73
ESEEr*/HSE 4.03 3.94 4.02 3.94 3.93 HEATING CAPACITy bLN (2) KW 418.1 467.6 545.7 623.9 702.0
input power (compressor) kW 116.0 130.0 151.8 173.4 195.0 total coP* 3.21 3.24 3.21 3.26 3.24
total coP*HSE 3.24 3.27 3.25 3.29 3.27 COOLING CAPACITy STD/HSE LN (1) 347.8 388.3 457.3 520.2 582.0
input power (compressor) 124.0 139.0 163.0 186.0 209.0 total EEr* 2.65 2.61 2.65 2.61 2.60
ESEEr* 3.86 3.81 3.86 3.81 3.80 total EEr*/ln HSE 2.70 2.67 2.70 2.67 2.66
ESEEr*/ln HSE 4.03 3.98 4.03 3.99 3.97 HEATING CAPACITy STD/HSE LN 396.4 443.9 517.1 591.2 665.4
input power (compressor) 115.0 130.0 152.0 173.0 194.0 total coP* 3.2 3.2 3.2 3.2 3.2
total coP*HSE 3.26 3.25 3.23 3.26 3.26COOLING CAPACITy STD/HSE ELN (1) KW 330.2 367.7 433.6 492.3 551.1
input power (compressor) kW 132.0 148.0 174.0 198.0 222.0 total EEr* 2.37 2.33 2.36 2.33 2.33
ESEEr* 3.59 3.53 3.57 3.52 3.52 total EEr*/Eln HSE 2.47 2.44 2.46 2.44 2.44
ESEEr*/Eln HSE 3.82 3.78 3.80 3.78 3.78 HEATING CAPACITy STD/HSE ELN (1) KW 379.8 426.4 496.3 567.6 639.0
input power (compressor) kW 115.0 129.0 151.8 172.8 193.8 total coP* 3.0 3.1 3.0 3.1 3.1
total coP*HSE 3.2 3.2 3.2 3.2 3.2COOLING CAPACITy HT KW 363.8 405.7 477.0 542.3 608.0
input power (compressor) kW 117.8 132.7 154.4 176.7 199.0 total EEr* 2.73 2.64 2.72 2.64 2.64
HEATING CAPACITy HT KW 422.0 473.0 551.0 630.0 709.0 input power (compressor) kW 114.8 128.7 150.3 171.7 193.0
total coP* 3.1 3.2 3.1 3.2 3.2Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz
Startup type Direct Direct Direct Direct Direct REFRIGERANT
type R410A number of refrigerant circuits 2 2 2 2 2
COMPRESSOR number 4 4 6 6 6
type Scroll Scroll Scroll Scroll Scroll EVAPORATOR
number 1 1 1 1 1type Plate Plate Plate Plate Plate
COIL number 4 4 4 4 4
FANS number 8 8 10 10 12
WATER CONNECTIONS (EVAPORATOR) type Victaulic
inlet/outlet diameter inches 4" 4" 4" 4" 4"WATER CONNECTIONS (DESUPERHEATER)
type Male GAS Threaded inlet/outlet diameter inches 2" 2" 2" 2" 2"
WEIGHT operating weight kg 2931 3056 4007 4123 4507
DIMENSIONS**length mm 4000 4000 5000 6000 6000 Width mm 2200 2200 2200 2200 2200
Height mm 2550 2550 2550 2550 2550 ACOUSTIC DATA
Sound power level Bln (3) dB(A) 97 97 98 98 99 Sound pressure level (4) dB(A) 65 65 66 66 67
Sound power level ln (3) dB(A) 91 91 92 92 93 Sound pressure level (4) dB(A) 59 59 60 60 61
Sound power level Eln (3) dB(A) 88 88 89 89 90 Sound pressure level (4) Eln dB(A) 56 56 57 57 58
Sound power level Ht (3) dB(A) 103 103 104 104 105 Sound pressure level (4) Ht dB(A) 71 71 72 72 73
(*) Gross value According to eurovent standard(**) Dimension without hydrokit(1) Data based on7°C leaving chilled water temperature and35°C ambient air temperature.(2) Data based on45°C leaving hot water temperature and7°C ambient air temperature with88 % relative humidity.(3) Sound levels are at fully loaded conditions. Sound power level values refer to ISO standard3744 and eurovent8/1.(4) Sound pressure level values refer to ISO standard3744, parallelepiped shape.
124
Commercial Air Conditioning |
125
AQSL 2612-4212air-coolEd cHillEr cooling capacity: from 605 to 926 kW refrigerant: r134a Sizes: 7
MAIN FeATUReS: 2 semi-hermetic screw compressors/2 independent refrigerant circuits
High efficiency pure counter-flow Shell & tube evaporator
top class EEr and ESEEr Partial (optional desuperheater) or total heat recovery (aQSr model)
VeRSIONS: Std: Standard HSE: High Seasonal Efficiency Ht: High temperature HPF: High Pressure Fan.
ACOUSTIC OPTIONS: Bln Basic low noise ln low noise Eln Extra low noise
PRODUCT ADVANTAGES 2 independant refrigerant circuits. 2 screw compressors. r134a refrigerant. class a EEr > 3,1 and ESEEr > 4,5. Bi-flow electronic expansion devices. High efficiency shell and tube counter flow evaporator. increasing the fin spacing to reduce fouling problems and increase air flow. Ec fans for Hight Seasonal Efficiency version and High temperature and High pressure Fans.
MAIN ACCESSORIES remote on/oFF control. ModBus protocol kit for BMS. lonwork protocol kit for BMS. Bacnet protocol kit for BMS. WEBctrl. remote keyboard panel. Master and slaves control, up to 4 units max. gSM. chiller grilles. Spring anti-vibration Flow switch. Water filter. remote hydro kits with buffer tank, 1 or 2 low or high pressure pump (relevant accessories and with or without tank antifreeze heater.
MAIN OPTIONS Stepless capacity control. compressors soft starter. Pressure actuated stepless fan speed controller for low ambient operation (-18°c) (Bln & ln versions). Power factor correction capacitors. automatic circuit breakers. HP & lP manometers. compressor liquid injection. compressor oil cooler. compressoir oil switch (standard on stepless control option). condenser coils with «Fin guard Silver» (polyurethane) treatment, with copper fins, with black epoxy treatment. High static pressure fans (ESP<120 Pa) for HPF version. coil guards and chiller grilles. compressor acoustic box. Water pump acoustic box. on board hydro kits without buffer tank, with 1 or 2 low or high pressure pump(s) and relevant accessories.condenser coils with blue fins treatment. 2 heat recovery options are available:desuperheater and total Heat recover aQSr.
Operating limit fOr Standard unitCOOLING MODE SizesLeaving water temperature without glycol 5/15°CLeaving water temperature with glycol on request
Outdoor air temperature BLN (1)
-5/49°C 2612-3212-4212-5/47°C 2812-3012-5/48°C 3412-3612
Outdoor air temperature LN (1)
-5/46°C 2612-5/47°C 3212-3412-3612-5/48°C 4212-5/45°C 2812-3012
Outdoor air temperature eLN-18/43°C all except-18/44°C 3212-18/46°C 4212
Outdoor air temperature HT* -18/49°C all except 2612-4212 -18/50(1) Minimum ambient temperature: -18°C with fan speed.
new
124 125
aQsl 2612 2812 3012 3212 3412 3612 4212COOLING CAPACITy STD/HSE/HPF bLN (1) KW 602 638 693 762 811 853 908
input power (compressor) kW 176 187 204 216 232 246 257 total EEr* 3.11 3.11 3.10 3.12 3.11 3.10 3.14
ESEEr* 4.15 4.17 4.08 3.95 4.02 4.07 4.05 total EEr*/HSE 3.13 3.13 3.13 3.15 3.14 3.13 3.17
ESEEr*/HSE 4.51 4.51 4.50 4.54 4.52 4.51 4.57 COOLING CAPACITy STD/HSE LN (1) 549 580 627 706 750 794 859
input power (compressor) 190 207 226 228 245 262 270 total EEr* 2.72 2.66 2.63 2.87 2.85 2.83 2.96
total EEr*/ln HSE 2.77 2.70 2.67 2.93 2.90 2.89 3.02 COOLING CAPACITy STD/HSE ELN (1) KW 528 558 596 661 715 744 822
input power (compressor) kW 200 216 239 240 262 284 286 total EEr* 2.50 2.45 2.37 2.56 2.55 2.46 2.68
total EEr*/Eln HSE 2.60 2.55 2.46 2.69 2.68 2.57 2.82 COOLING CAPACITy HT (1) KW 605 642 696 771 816 855 924
input power (compressor) kW 174 187 204 214 231 248 253 total EEr* 3.01 3.00 2.98 3.01 2.98 2.94 3.07
Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz Startup type S/D S/D S/D S/D S/D S/D S/D
REFRIGERANT
type R134anumber of refrigerant circuits 2 2 2 2 2 2 2
COMPRESSOR
number 2 2 2 2 2 2 2type Screw Screw Screw Screw Screw Screw Screw
EVAPORATOR
number 1 1 1 1 1 1 1 type S&T S&T S&T S&T S&T S&T S&T
COIL
number 4 4 4 4 4 4 4FANS
number 10 10 11 16 16 16 18WATER CONNECTIONS (EVAPORATOR)
type Victaulicinlet/outlet diameter inches 8" 8" 8" 8" 8" 8" 8"
WATER CONNECTIONS (DESUPERHEATER)
type Male GAS Threaded inlet/outlet diameter inches 2" 2" 2" 2" 2" 2" 2"
WEIGHT
operating weight kg 5149 5259 5568 6447 6938 6955 7538 operating weight Eln kg 5264 5374 5683 6562 7053 7070 7653
DIMENSIONS**
length mm 6170 6170 6170 8110 8110 8110 10050 Width mm 2172 2172 2172 2172 2172 2172 2172
Height mm 2550 2550 2550 2550 2550 2550 2550 ACOUSTIC DATA
Sound power level Bln (3) dB(A) 96 96 96 97 97 97 98 Sound pressure level (4) dB(A) 64 64 64 65 65 65 66
Sound power level ln (3) dB(A) 94 94 94 95 95 95 96 Sound pressure level ln (4) dB(A) 62 62 62 63 63 63 64 Sound power level Eln (3) dB(A) 92 92 92 93 93 93 94
Sound pressure level Eln (4) dB(A) 60 60 60 61 61 61 62 Sound power level Ht (3) dB(A) 103 103 103 104 104 104 105
Sound pressure level Ht (4) dB(A) 71 71 71 72 72 72 73
(*) Gross value According to eurovent standard.(**) Dimension without hydrokit.(1) Data based on 7°C leaving chilled water temperature and 35°C ambient air temperature.(3) Sound levels are at fully loaded conditions. Sound power level values at 10 m refer to ISO standard 3744 and eurovent 8/1.(4) Sound pressure level values refer to ISO standard 3744, parallelepiped shape.
126
Commercial Air Conditioning |
127
SLS STD 1202-8404air-coolEd cHillEr
cooling capacity: from 300 to 1690 kW refrigerant: r134a Sizes: 16
MAIN FeATUReS: 2 or 4 semi-hermetic screw compressors/2 or 4 refrigerant circuits
Shell & tube evaporator Wide range of hydrokit available
ACOUSTIC OPTIONS: Bln Basic low noise ln low noise Eln Extra low noise
PRODUCT ADVANTAGES 2 independant refrigerant circuits. 2 screw compressors. r134a refrigerant. Bi-flow electronic expansion devices. Shell and tube evaporator.
MAIN ACCESSORIES remote on/oFF control. remote keyboard panel. Master/slaves control up to 4 units maximum. chiller grilles. Spring type anti-vibration mounts. Flow switch. Water filter. remote hydro kit with 750 or 1000 litre water tank, 1 or 2 low or high pressure pump(s), relevant accessories and with or without antifreeze electric heater.
MAIN OPTIONS ModBus,lonwork, Bacnet protocol kit for BMS. WEBctrl. compressor soft starting. Pressure actuated stepless fan speed controller for low ambient operation (-18°c) (Bln & ln versions). Sequence phase control. Power factor correction capacitors. Electronic expansion valves. gSM. HP and lP manometers. compressor suction valves. Mufflers and anti-vibration pipe compressor liquid injection. compressor oil cooler or compressor oil level switch. condenser coils with blue fin treatment, with “Fin guard Silver” (polyurethane) treatment and with copper fins. coil guards and chiller grilles. compressor acoustic box (Bln version). Water pump acoustic box (Bln & ln versions). total heat recovery and desuperheater. on board hydro kit without water tank, but with 1 or 2 low or high pressure pump(s), relevant accessories and with or without antifreeze electric heater for hydraulic manifolds. on board hydro kit to be installed on the back of the unit, with 750 or 1000 litre water tank, 1 or 2 low or high pressure pump(s) and relevant accessories. Water tank alone without pump, to be installed on the back of the unit:???
Operating limit fOr Standard unitCOOLING MODE SizesLeaving water temperature without glycol 5/15°C
Outdoor air temperature BLN (1)
-5/45°C 1402-1802-2002-6004-6404-6804-7204
-5/44°C 1602-1902-2202
-5/43°C 2502-2702-5004-5404-5704-8404
Outdoor air temperature LN (1)
-5/42°C 1402-1802-2002-6004-6404-6804-7204
-5/41°C 1602-1902-2202
-5/40°C 2502-2702-5004-5404-5704-8404
Outdoor air temperature eLN
-18/42°C 1402-1802-2002-6004-6404-6804-7204
-18/41°C 1602-1902-2202
-18/40°C 2502-2702-5004-5404-5704-8404
(1) Minimum ambient temperature: -18°C with fan speed.
126 127
sls 1402 1602 1802 1902 2002COOLING CAPACITy STD bLN (1) KW 293.0 326.2 365.6 410.6 455.5
input power (compressor) kW 95.8 111.8 126.2 150.4 159.6 total EEr* 3.01 2.90 2.83 2.76 2.78
COOLING CAPACITy STD LN/ELN (1) 275.4 306.6 343.7 386.0 428.2
input power (compressor) 95.7 111.4 125.6 144.3 158.2 total EEr* 2.73 2.63 2.58 2.52 2.55
Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz Startup type P/W (Part-Winding)
REFRIGERANT
type R134anumber of refrigerant circuits 2 2 2 2 2
COMPRESSOR
number 2 2 2 2 2 type Screw Screw Screw Screw Screw
EVAPORATOR
number 1 1 1 1 1 type S&T S&T S&T S&T S&T
COIL
number 4 4 4 4 4 FANS
number 4 4 6 7 8 WATER CONNECTIONS (EVAPORATOR)
type Victaulicinlet/outlet diameter inches 5" 5" 5" 5" 6"
WEIGHT
operating weight kg 3625 3643 3716 4207 4680 operating weight ln/Eln kg 3733 3751 3824 4315 4788
DIMENSIONS**
length mm 4000 4000 4000 4000 4000 Width mm 2200 2200 2200 2200 2200
Height mm 2550 2550 2550 2550 2550 ACOUSTIC DATA
Sound power level Bln (3) dB(A) 96 96 97 98 98 Sound pressure level (4) dB(A) 64 64 65 66 66
Sound power level ln (3) dB(A) 91 91 92 92 92 Sound pressure level ln (4) dB(A) 59 59 60 60 60 Sound power level Eln (3) dB(A) 87 87 88 88 88
Sound pressure level Eln (4) dB(A) 55 55 56 56 56
(*) Gross value According to eurovent standard.(**) Dimension without hydrokit.(1) Data based on 7°C leaving chilled water temperature and 35°C ambient air temperature.(3) Sound levels are at fully loaded conditions. Sound power level values refer to ISO standard 3744 and eurovent 8/1.(4) Sound pressure level values refer to ISO standard 3744. parallelepiped shape.
128
Commercial Air Conditioning |
129
sls 2202 2502 2702 5004 5404COOLING CAPACITy STD bLN (1) KW 480.5 513.6 546.8 1027.2 1093.6
input power (compressor) kW 175.6 189.6 203.6 355.8 382.2 total EEr* 2.68 2.67 2.66 2.67 2.66
COOLING CAPACITy STD LN/ELN (1) 451.7 482.8 514.0 965.6 1028.0
input power (compressor) 174.6 188.6 202.6 377.1 405.1 total EEr* 2.45 2.43 2.42 2.43 2.42
Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz Startup type S/D (Star-delta)
REFRIGERANT
type R134anumber of refrigerant circuits 2 2 2 4 4
COMPRESSOR
number 2 2 2 4 4type Screw Screw Screw Screw Screw
EVAPORATOR
number 1 1 1 2 2type S&T S&T S&T S&T S&T
COIL
number 4 4 4 8 8 FANS
number 8 8 8 16 16 WATER CONNECTIONS (EVAPORATOR)
type Victaulicinlet/outlet diameter inches 6" 6" 6" 6" 6"
WEIGHT
operating weight kg 4689 4738 4756 9467 9503 operating weight ln/Eln kg 4797 4846 4864 9683 9719
DIMENSIONS**
length mm 4000 4000 4000 8000 8000 Width mm 2200 2200 2200 2200 2200
Height mm 2550 2550 2550 2550 2550 ACOUSTIC DATA
Sound power level Bln (3) dB(A) 98 98 98 101 101 Sound pressure level (4) dB(A) 66 66 66 69 69
Sound power level ln (3) dB(A) 92 92 92 95 95 Sound pressure level ln (4) dB(A) 60 60 60 63 63 Sound power level Eln (3) dB(A) 88 88 88 91 91
Sound pressure level Eln (4) dB(A) 56 56 56 59 59
(*) Gross value According to eurovent standard.(**) Dimension without hydrokit.(1) Data based on 7°C leaving chilled water temperature and 35°C ambient air temperature.(3) Sound levels are at fully loaded conditions. Sound power level values refer to ISO standard 3744 and eurovent 8/1.(4) Sound pressure level values refer to ISO standard 3744, parallelepiped shape.
128 129
sls 5704 6004 6404 6804 7204 8404COOLING CAPACITy STD bLN (1) KW 1167.1 1240.6 1320.0 1437.2 1517.6 1646.6
input power (compressor) kW 385.3 388.4 430.2 469.2 508.2 579.0 total EEr* 2.77 2.87 2.79 2.80 2.75 2.65
COOLING CAPACITy STD LN/ELN (1) 1097.1 1166.2 1240.8 1351.0 1426.5 1547.8
input power (compressor) 408.4 411.7 456.0 497.4 538.7 613.7 total EEr* 2.53 2.64 2.55 2.56 2.51 2.40
Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz Startup type S/D (Star-delta)
REFRIGERANT
type R134anumber of refrigerant circuits 4 4 4 4 4 4
COMPRESSOR
number 4 4 4 4 4 4type Screw Screw Screw Screw Screw Screw
EVAPORATOR
number 2 2 2 2 2 2type S&T S&T S&T S&T S&T S&T
COIL
number 8 8 8 8 8 8 FANS
number 20 24 24 24 24 24 WATER CONNECTIONS (EVAPORATOR)
type Victaulicinlet/outlet diameter inches 6" 6" 8" 8" 8" 8"
WEIGHT
operating weight kg 11207 12912 13639 13950 14247 14442 operating weight ln/Eln kg 11423 13128 13855 14166 14463 14658
DIMENSIONS**
length mm 10000 12000 12000 12000 12000 12000 Width mm 2200 2200 2200 2200 2200 2200
Height mm 2550 2550 2550 2550 2550 2550 ACOUSTIC DATA
Sound power level Bln (3) dB(A) 102 103 103 103 103 103 Sound pressure level (4) dB(A) 69 70 70 70 70 70
Sound power level ln (3) dB(A) 96 97 97 97 97 97 Sound pressure level ln (4) dB(A) 63 64 64 64 64 64 Sound power level Eln (3) dB(A) 92 93 93 93 93 93
Sound pressure level Eln (4) dB(A) 59 60 60 60 60 60
(*) Gross value According to eurovent standard.(**) Dimension without hydrokit.(1) Data based on 7°C leaving chilled water temperature and 35°C ambient air temperature.(3) Sound levels are at fully loaded conditions. Sound power level values refer to ISO standard 3744 and eurovent 8/1.(4) Sound pressure level values refer to ISO standard 3744. parallelepiped shape.
130
Commercial Air Conditioning |
131
SLS HE 1202-8404air-coolEd cHillEr
cooling capacity: from 300 to 1690 kW refrigerant: r134a Sizes: 16
MAIN FeATUReS: 2 or 4 semi-hermetic screw compressors/2 or 4 refrigerant circuits
Shell & tube evaporator Wide range of hydrokit available
ACOUSTIC OPTIONS: Bln Basic low noise ln low noise Eln Extra low noise
PRODUCT ADVANTAGES 2 independant refrigerant circuits. 2 screw compressors. r134a refrigerant. Bi-flow electronic expansion devices. Shell and tube evaporator. High Efficiency thanks to the greater surface area condenser coils and by the greater number of fans versus SlS Std.
MAIN ACCESSORIES remote on/oFF control. remote keyboard panel. Master/slaves control up to 4 units maximum. chiller grilles. Spring type anti-vibration mounts. Flow switch. Water filter. remote hydro kit with 750 or 1000 litre water tank, 1 or 2 low or high pressure pump(s), relevant accessories and with or without antifreeze electric heater.
MAIN OPTIONS ModBus,lonwork, Bacnet protocol kit for BMS. WEBctrl. compressor soft starting. Pressure actuated stepless fan speed controller for low ambient operation (-18°c) (Bln & ln versions). Sequence phase control. Power factor correction capacitors. Electronic expansion valves. gSM. HP and lP manometers. compressor suction valves. Mufflers and anti-vibration pipe compressor liquid injection. compressor oil cooler or compressor oil level switch. condenser coils with blue fin treatment, with “Fin guard Silver” (polyurethane) treatment and with copper fins. coil guards and chiller grilles. compressor acoustic box (Bln version). Water pump acoustic box (Bln & ln versions). total heat recovery and desuperheater. on board hydro kit without water tank, but with 1 or 2 low or high pressure pump(s), relevant accessories and with or without antifreeze electric heater for hydraulic manifolds. on board hydro kit to be installed on the back of the unit, with 750 or 1000 litre water tank, 1 or 2 low or high pressure pump(s) and relevant accessories. Water tank alone without pump, to be installed on the back of the unit:???
Operating limit fOr Standard unitCOOLING MODE SizesLeaving water temperature without glycol 5/15°CLeaving water temperature with glycol ???
Outdoor air temperature BLN (1)
-5/48°C 1402-2402-2602-4804-5204-5604
-5/47°C 1602-1802-1902-2002-6004-6404
-5/44°C 6804-7204-7804-8404
Outdoor air temperature LN (1)-5/45°C 1402-2402-2602-5/44°C 1602-1802-1902-2002-5/41°C 6804-7204-7804-8404
Outdoor air temperature eLN-18/45°C 1402-2402-2602-18/44°C 1602-1802-1902-2002-18/41°C 6804-7204-7804-8404
(1) Minimum ambient temperature: -18°C with fan speed.
130 131
sls he 1402 1602 1802 1902 2002COOLING CAPACITy STD bLN (1) KW 304.0 338.0 378.0 425.0 467.2
input power (compressor) kW 85.8 99.5 116.3 132.7 143.3 total EEr* 3.15 3.06 2.89 2.89 2.96
COOLING CAPACITy STD LN/ELN (1) 291.8 324.5 362.9 408.0 448.5
input power (compressor) 90.9 105.5 123.3 140.7 151.9 total EEr* 2.96 2.87 2.72 2.71 2.77
Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz Startup type P/W (Part-Winding)
REFRIGERANT
type R134anumber of refrigerant circuits 2 2 2 2 2
COMPRESSOR
number 2 2 2 2 2 type Screw Screw Screw Screw Screw
EVAPORATOR
number 1 1 1 1 1 type S&T S&T S&T S&T S&T
COIL
number 4 4 4 4 4 FANS
number 6 6 8 8 8 WATER CONNECTIONS (EVAPORATOR)
type Victaulicinlet/outlet diameter inches 5" 5" 5" 5" 6"
WEIGHT
operating weight kg 3697 3715 3788 4333 5544 operating weight ln/Eln kg 3805 3823 3896 4441 5652
DIMENSIONS**
length mm 4000 4000 4000 4000 6000 Width mm 2200 2200 2200 2200 2200
Height mm 2550 2550 2550 2550 2550 ACOUSTIC DATA
Sound power level Bln (3) dB(A) 97 97 98 98 98 Sound pressure level (4) dB(A) 65 65 66 66 66
Sound power level ln (3) dB(A) 92 92 92 92 92 Sound pressure level ln (4) dB(A) 60 60 60 60 60 Sound power level Eln (3) dB(A) 86 86 87 87 87
Sound pressure level Eln (4) dB(A) 54 54 55 55 55
(*) Gross value According to eurovent standard.(**) Dimension without hydrokit.(1) Data based on 7°C leaving chilled water temperature and 35°C ambient air temperature.(3) Sound levels are at fully loaded conditions. Sound power level values refer to ISO standard 3744 and eurovent 8/1.(4) Sound pressure level values refer to ISO standard 3744, parallelepiped shape.
132
Commercial Air Conditioning |
133
sls he 2402 2602 4804 5204 5604COOLING CAPACITy STD bLN (1) KW 531.0 571.0 1062.0 1142.0 1208.0
input power (compressor) kW 154.9 163.1 309.8 326.2 342.4 total EEr* 3.07 3.15 3.07 3.15 3.19
COOLING CAPACITy STD LN/ELN (1) 509.8 548.2 1019.5 1096.3 1159.7
input power (compressor) 164.2 172.9 328.4 345.8 362.9 total EEr* 2.88 2.96 2.88 2.96 2.99
Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz Startup type S/D (Star-delta)
REFRIGERANT
type R134anumber of refrigerant circuits 2 2 4 4 4
COMPRESSOR
number 2 2 4 4 4type Screw Screw Screw Screw Screw
EVAPORATOR
number 1 1 2 2 2type S&T S&T S&T S&T S&T
COIL
number 4 4 8 8 8FANS
number 10 10 20 20 20WATER CONNECTIONS (EVAPORATOR)
type Victaulicinlet/outlet diameter inches 6" 6" 6" 6" 6"
WEIGHT
operating weight kg 5665 5790 11321 11580 12561 operating weight ln/Eln kg 5773 5898 11537 11796 12777
DIMENSIONS**
length mm 6000 6000 12000 12000 12000 Width mm 2200 2200 2200 2200 2200
Height mm 2550 2550 2550 2550 2550 ACOUSTIC DATA
Sound power level Bln (3) dB(A) 99 99 102 102 102 Sound pressure level (4) dB(A) 67 67 69 69 69
Sound power level ln (3) dB(A) 93 93 96 96 96 Sound pressure level ln (4) dB(A) 61 61 63 63 63 Sound power level Eln (3) dB(A) 87 87 90 90 90
Sound pressure level Eln (4) dB(A) 55 55 57 57 57
(*) Gross value According to eurovent standard.(**) Dimension without hydrokit.(1) Data based on 7°C leaving chilled water temperature and 35°C ambient air temperature.(3) Sound levels are at fully loaded conditions. Sound power level values refer to ISO standard 3744 and eurovent 8/1.(4) Sound pressure level values refer to ISO standard 3744, parallelepiped shape.
132 133
sls he 6004 6404 6804 7204 7804 8404COOLING CAPACITy STD bLN (1) KW 1292.8 1406.4 1482.2 1557.9 1637.2 1686.9
input power (compressor) kW 377.8 419.8 467 514.2 543.3 575.0 total EEr* 3,07 3,04 2,91 2,79 2,79 2,73
COOLING CAPACITy STD LN/ELN (1) 1241.1 1350.1 1422.9 1495.6 1571.7 1619.4
input power (compressor) 400.5 445.0 495.0 545.1 575.9 609.5 total EEr* 2,88 2,84 2,71 2,60 2,59 2,53
Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz Startup type
REFRIGERANT
type R134anumber of refrigerant circuits 4 4 4 4 4 4
COMPRESSOR
number 4 4 4 4 4 4type Screw Screw Screw Screw Screw Screw
EVAPORATOR
number 2 2 2 2 2 2type S&T S&T S&T S&T S&T S&T
COIL
number 8 8 8 8 8 8FANS
number 24 24 24 24 24 24WATER CONNECTIONS (EVAPORATOR)
type Victaulicinlet/outlet diameter inches 6" 8" 8" 8" 8" 8"
WEIGHT
operating weight kg 13388 14085 14135 14421 14542 14659 operating weight ln/Eln kg 13604 14301 14351 14637 14758 14875
DIMENSIONS**
length mm 12000 12000 12000 12000 12000 12000 Width mm 2200 2200 2200 2200 2200 2200
Height mm 2550 2550 2550 2550 2550 2550 ACOUSTIC DATA
Sound power level Bln (3) dB(A) 103 103 103 103 103 103 Sound pressure level (4) dB(A) 70 70 70 70 70 70
Sound power level ln (3) dB(A) 97 97 97 97 97 97 Sound pressure level ln (4) dB(A) 64 64 64 64 64 64 Sound power level Eln (3) dB(A) 91 91 93 93 93 93
Sound pressure level Eln (4) dB(A) 58 58 60 60 60 60
(*) Gross value According to eurovent standard.(**) Dimension without hydrokit.(1) Data based on 7°C leaving chilled water temperature and 35°C ambient air temperature.(3) Sound levels are at fully loaded conditions. Sound power level values refer to ISO standard 3744 and eurovent 8/1.(4) Sound pressure level values refer to ISO standard 3744, parallelepiped shape.
134
Commercial Air Conditioning |
135
WQL 20-45WatEr-coolEd cHillEr
cooling capacity: from 21 to 47 kW refrigerant: r410a Sizes: 6
MAIN FeATUReS: Single scroll compressors compact design Hydrokit for source and user sides (optional) also available as Heating only unit
ACOUSTIC OPTIONS: Bln Base low noise Eln Extra low noise
PRODUCT ADVANTAGES lot of sizes available to be more closer to the needs. r410a refrigerant. 2 different level sound finition (Bln basic low noise or Eln Extra low noise version). Single or tandem Scroll compressors. reduced refrigerant charge (less than 10 kgs per circuit for units up to 90 kW. new electronic controller with auto-adaptative function to reduce water content in the piping system. condensing pressure control available as option for well application. wide range of hydrokit for “plug and play” units. dHW (domestic Hot Water)function available on the controller with 3 ways valve available as accessory. Victaulic joints for all internal water piping connections. desuperheater heat exchanger available as option (50-190 sizes). dynamic setpoint (4-20ma, 0-1V, 0-5V, 0-10V). outdoor air temperature compensation. double set point.
MAIN OPTIONS Modbus protocol kit for BMS. compressor soft starter. Electronic expansion valve. condensing control kit. Electric heater wiring kit. additional heating device wiring kit. Mechanical gauges kit. on board hydrokit. desuperheater.
MAIN ACCESSORIES (field to be installed)
remotez on-off. remote keyboard panel. Sequencer up to 4 units. condensing control kit. Water temperature sensor for dHW tank. outdoor air sensor for weather compensation. Electric heater wiring kit. additional heating device wiring kit. Pressostatic water valve for well application (only for sizes 20 to 45). compressor jacket. Flow switch. Pressure switch. Victaulic to threaded pipe connection. 3 way valve for dHW production. Spring type anti-vibration mounts (only for sizes 50 to 190). Water filter. Valves in/out (only for sizes 20 to 45).
Operating limit fOr Standard unitCOOLING MODE
Chilled liquid: Leaving water temperature 5/18°C
Chilled liquid: Leaving water temperature with glycol
-8/+5°C (with glycol and electronic
expansion valve)
+5/+18°C (standard application)
Heated liquid: Leaving water temperature 25/55°C
Condensing temperature WQRC 30/58°C
NOTES Operating limits are referred to full load.Maximum % glycol (ethylenic or propilenic): 40%.
R410A
134 135
wQl 20 25 30 35 40 45COOLING CAPACITy WQL (1) KW 21.3 26.4 31.3 35.1 39.5 46.9
input power (compressor) kW 4.4 5.5 6.4 7.2 8.2 9.7Heat rejection kW 25.7 31.9 37.7 42.3 47.7 56.6
EEr 4.81 4.82 4.86 4.90 4.84 4.86ESEEr 5.44 5.43 5.41 5.38 5.21 5.44
COOLING CAPACITy WQRC (2) 20.9 26.0 31.3 34.8 39.3 46.2
input power (compressor) 4.54 5.61 6.37 7.24 8.15 9.89Heat rejection kW 25.5 31.6 37.7 42.0 47.5 56.1
EEr 4.60 4.63 4.91 4.80 4.82 4.67Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz
Startup type Direct Direct Direct Direct Direct Direct REFRIGERANT
type R410Anumber of refrigerant circuits 1 1 1 1 1 1
COMPRESSOR
number 1 1 1 1 1 1type Scroll Scroll Scroll Scroll Scroll Scroll
EVAPORATOR
number 1 1 1 1 1 1 type Plate Plate Plate Plate Plate Plate
CONDENSER
number 1 1 1 1 1 1type Plate Plate Plate Plate Plate Plate
WATER CONNECTIONS (EVAPORATOR)
type Victaulicinlet/outlet diameter inches 1"1/2 1"1/2 1"1/2 1"1/2 1"1/2 1"1/2
WATER CONNECTIONS (CONDESER)
type Victaulicinlet/outlet diameter inches 1"1/2 1"1/2 1"1/2 1"1/2 1"1/2 1"1/2
REFRIGERANT COMMECTION (WQR)
type To be brazedinlet/outlet diameter inches 5/8" 5/8" -7/8" 5/8" -7/8" 5/8" -7/8" 5/8" -7/8" 5/8" -7/8"
WEIGHT
operating weight WQl kg 156 176 174 179 185 203operating weight WQrc 144 164 166 166 172 172
diMEnSionS LENGTH MM 821 821 821 821 821 821
Width mm 455 455 455 455 455 455Height mm 1350 1350 1350 1350 1350 1350
ACOUSTIC DATA
Sound power level dB(A) 65 67 67 68 69 70Sound pressure level (3) dB(A) 34 36 36 37 38 39Sound power level Eln dB(A) 62 64 64 65 66 67
Sound pressure level (3) Eln dB(A) 31 33 33 34 35 36
(1) At conditions: evaporator water temperature of 12/7°C and condenser water temperature of 30/35°C.(2) evaporator eWT/LWT 12°C/7°C, condensing temperature 40 [°C].(3) Sound pressure level at 10 m.- Values refers to ISO Standard 3744 with parallepiped shape.
136
Commercial Air Conditioning |
137
WQL 50-190WatEr-coolEd cHillEr
cooling capacity: from 51 to 193 kW refrigerant: r410a Sizes: 8
MAIN FeATUReS: 2 scroll compressors/1 refrigerant circuit desuperheater for partial heat recovery Hydrokit for source and user sides (optional) also available as Heating only unit
ACOUSTIC OPTIONS: Bln Base low noise Eln Extra low noise
Operating limit fOr Standard unitCOOLING MODE
Chilled liquid: Leaving water temperature 5/18°C
Chilled liquid: Leaving water temperature with glycol
-8/+5°C (with glycol and electronic
expansion valve)
+5/+18°C (standard application)
Heated liquid: Leaving water temperature 25/55°C
Condensing temperature WQRC 30/58°C
NOTES Operating limits are referred to full load.Maximum % glycol (ethylenic or propilenic): 40%.
PRODUCT ADVANTAGES lot of sizes available to be more closer to the needs. r410a refrigerant. 2 different level sound finition (Bln basic low noise or Eln Extra low noise version). Single or tandem Scroll compressors. reduced refrigerant charge (less than 10 kgs per circuit for units up to 90 kW. new electronic controller with auto-adaptative function to reduce water content in the piping system. condensing pressure control available as option for well application. wide range of hydrokit for “plug and play” units. dHW (domestic Hot Water)function available on the controller with 3 ways valve available as accessory. Victaulic joints for all internal water piping connections. desuperheater heat exchanger available as option (50-190 sizes). dynamic setpoint (4-20ma, 0-1V, 0-5V, 0-10V). outdoor air temperature compensation. double set point.
MAIN OPTIONS Modbus protocol kit for BMS. compressor soft starter. Electronic expansion valve. condensing control kit. Electric heater wiring kit. additional heating device wiring kit. Mechanical gauges kit. on board hydrokit. desuperheater.
MAIN ACCESSORIES (field to be installed)
remotez on-off. remote keyboard panel. Sequencer up to 4 units. condensing control kit. Water temperature sensor for dHW tank. outdoor air sensor for weather compensation. Electric heater wiring kit. additional heating device wiring kit. Pressostatic water valve for well application (only for sizes 20 to 45). compressor jacket. Flow switch. Pressure switch. Victaulic to threaded pipe connection. 3 way valve for dHW production. Spring type anti-vibration mounts (only for sizes 50 to 190). Water filter. Valves in/out (only for sizes 20 to 45).
R410A
136 137
wQl 50 60 75 90 120 150 170 190COOLING CAPACITy WQL (1) KW 51.1 61.3 77.6 91.4 118.8 147.5 170.5 193.3
input power (compressor) kW 11.3 13.1 16.6 20.1 25.7 31.9 36.5 41.4Heat rejection kW 62.4 74.4 94.2 111.5 144.5 179.4 207.0 234.7
EEr 4.5 4.7 4.7 4.5 4.6 4.6 4.7 4.7ESEEr 6.4 6.6 6.1 6.6 6.2 6.0 6.0 6.0
COOLING CAPACITy WQRC(2) 51.2 61.7 77.8 91.4 118.7 147.6 169.4 193.2
input power (compressor) 11.2 12.9 16.5 20.0 25.7 31.8 36.9 41.4Heat rejection kW 62.4 74.6 94.3 111.4 144.4 179.4 206.3 234.6
EEr 4.6 4.8 4.7 4.6 4.6 4.6 4.6 4.7Power supply 400V/3/50Hz
Startup type Direct Direct Direct Direct Direct Direct Direct Direct REFRIGERANT
type R410Anumber of refrigerant circuits 1 1 1 1 1 1 1 1COMPRESSOR
number 2 2 2 2 2 2 2 2type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll
EVAPORATOR
number 1 1 1 1 1 1 1 1 type Plate Plate Plate Plate Plate Plate Plate Plate
CONDENSER
number 1 1 1 1 1 1 1 1type Plate Plate Plate Plate Plate Plate Plate Plate
WATER CONNECTIONS (EVAPORATOR)
type Victaulicinlet/outlet diameter inches 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2
WATER CONNECTIONS (CONDESER)
type Victaulicinlet/outlet diameter inches 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2
REFRIGERANT COMMECTION (WQR)
type To be brazedinlet/outlet diameter inches 7/8"-5/8" 7/8"-5/8" 11/8'' -7/8" 11/8'' -7/8" 13/8'' -7/8" 15/8'' -7/8" 15/8'' -7/8" 15/8'' -7/8"
WEIGHT
operating weight WQl kg 440 491 540 591 837 966 1041 1145operating weight WQrc 376 404 439 466 678 762 813 874
DIMENSIONS
length mm 1210 1210 1210 1210 1210 1210 1210 1210Width mm 850 850 850 850 850 850 850 850
Height mm 1500 1500 1500 1500 1500 1500 1500 1500ACOUSTIC DATA
Sound power level dB(A) 70 70 72 73 78 81 81 81Sound pressure level (3) dB(A) 39 39 41 42 47 50 50 50Sound power level Eln dB(A) 68 68 70 71 76 79 79 79
Sound pressure level (3) Eln dB(A) 37 37 39 40 45 48 48 48
(1) At conditions: evaporator water temperature of12/7°C and condenser water temperature of30/35°C.(2) evaporator eWT/LWT12°C/7°C, condensing temperature40 [°C].(3) Sound pressure level at10 m.- Values refers to ISO Standard 3744 with parallepiped shape.
138
Commercial Air Conditioning |
139
WQH 20-45WatEr-to-WatEr HEat PuMP
cooling capacity: from 21 to 46 kW Heating capacity: from 24 to 51 kW refrigerant: r410a Sizes: 6
MAIN FeATUReS: Single scroll compressors compact design Hydrokit for source and user sides (optional) Production of dHW
ACOUSTIC OPTIONS: Bln Base low noise Eln Extra low noise
Operating limit fOr Standard unitCOOLING MODE
Chilled liquid: Leaving water temperature 5/18°C
Chilled liquid: Leaving water temperature with glycol
-8/+5°C (with glycol and electronic
expansion valve)
+5/+18°C (standard application)
Heated liquid: Leaving water temperature 25/55°C
Condensing temperature WQRC 30/58°C
NOTES Operating limits are referred to full load.Maximum % glycol (ethylenic or propilenic): 40%.
PRODUCT ADVANTAGES lot of sizes available to be more closer to the needs. r410a refrigerant. 2 different level sound finition (Bln basic low noise or Eln Extra low noise version). Single or tandem Scroll compressors. reduced refrigerant charge (less than 10 kgs per circuit for units up to 90 kW. new electronic controller with auto-adaptative function to reduce water content in the piping system. condensing pressure control available as option for well application. wide range of hydrokit for “plug and play” units. dHW (domestic Hot Water)function available on the controller with 3 ways valve available as accessory. Victaulic joints for all internal water piping connections. desuperheater heat exchanger available as option (50-190 sizes). dynamic setpoint (4-20ma, 0-1V, 0-5V, 0-10V). outdoor air temperature compensation. double set point.
MAIN OPTIONS Modbus protocol kit for BMS. compressor soft starter. Electronic expansion valve. condensing control kit. Electric heater wiring kit. additional heating device wiring kit. Mechanical gauges kit. on board hydrokit. desuperheater.
MAIN ACCESSORIES (field to be installed)
remotez on-off. remote keyboard panel. Sequencer up to 4 units. condensing control kit. Water temperature sensor for dHW tank. outdoor air sensor for weather compensation. Electric heater wiring kit. additional heating device wiring kit. Pressostatic water valve for well application (only for sizes 20 to 45). compressor jacket. Flow switch. Pressure switch. Victaulic to threaded pipe connection. 3 way valve for dHW production. Spring type anti-vibration mounts (only for sizes 50 to 190). Water filter. Valves in/out (only for sizes 20 to 45).
R410A
new
138 139
wQh 20 25 30 35 40 45COOLING CAPACITy (1) KW 20.9 26.1 30.3 34.2 38.4 45.8
input power (compressor) kW 4.49 5.52 6.52 7.32 8.26 9.84Heat rejection kW 25.4 31.6 36.8 41.5 46.7 55.6
EEr 4.65 4.73 4.65 4.67 4.65 4.65ESEEr 5.16 5.37 5.26 5.26 5.05 5.19
HEATING CAPACITy (2) KW 23.5 28.6 33.4 38.2 42.6 50.6
input power (compressor) kW 5.66 6.90 8.05 9.21 10.30 12.20coP 4.15 4.14 4.15 4.15 4.14 4.15
Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz Startup type Direct Direct Direct Direct Direct Direct
REFRIGERANT
type R410Anumber of refrigerant circuits 1 1 1 1 1 1
COMPRESSOR
number 1 1 1 1 1 1type Scroll Scroll Scroll Scroll Scroll Scroll
EVAPORATOR
number 1 1 1 1 1 1 type Plate Plate Plate Plate Plate Plate
CONDENSER
number 1 1 1 1 1 1type Plate Plate Plate Plate Plate Plate
WATER CONNECTIONS (EVAPORATOR)
type Victaulicinlet/outlet diameter inches 1"1/2 1"1/2 1"1/2 1"1/2 1"1/2 1"1/2
WATER CONNECTIONS (CONDESER)
type Victaulicinlet/outlet diameter inches 1"1/2 1"1/2 1"1/2 1"1/2 1"1/2 1"1/2
WEIGHT
operating weight kg 159 181 179 184 190 208DIMENSIONS
length mm 821 821 821 821 821 821Width mm 455 455 455 455 455 455
Height mm 1350 1350 1350 1350 1350 1350ACOUSTIC DATA
Sound power level dB(A) 65 67 67 68 69 70Sound pressure level (3) dB(A) 34 36 36 37 38 39Sound power level Eln dB(A) 62 64 64 65 66 67
Sound pressure level (3) Eln dB(A) 31 33 33 34 35 36
(1) At conditions: evaporator water temperature of 12/7°C and condenser water temperature of 30/35°C.(2) evaporator eWT/LWT 12°C/7°C, condensing temperature 40 [°C].(3) Sound pressure level at 10 m.- Values refers to ISO Standard 3744 with parallepiped shape.
140
Commercial Air Conditioning |
141
WQH 50-190WatEr-to-WatEr HEat PuMP
cooling capacity: from 50 to 186 kW Heating capacity: from 57 to 210 kW refrigerant: r410a Sizes: 8
MAIN FeATUReS: 2 scroll compressors/1 refrigerant circuit desuperheater for partial heat recovery Hydrokit for source and user sides (optional)
ACOUSTIC OPTIONS: Bln Base low noise Eln Extra low noise
Operating limit fOr Standard unitCOOLING MODE
Chilled liquid: Leaving water temperature 5/18°C
Chilled liquid: Leaving water temperature with glycol
-8/+5°C (with glycol and electronic
expansion valve)
+5/+18°C (standard application)
Heated liquid: Leaving water temperature 25/55°C
Condensing temperature WQRC 30/58°C
NOTES Operating limits are referred to full load.Maximum % glycol (ethylenic or propilenic): 40%.
PRODUCT ADVANTAGES lot of sizes available to be more closer to the needs. r410a refrigerant. 2 different level sound finition (Bln basic low noise or Eln Extra low noise version). Single or tandem Scroll compressors. reduced refrigerant charge (less than 10 kgs per circuit for units up to 90 kW. new electronic controller with auto-adaptative function to reduce water content in the piping system. condensing pressure control available as option for well application. wide range of hydrokit for “plug and play” units. dHW (domestic Hot Water)function available on the controller with 3 ways valve available as accessory. Victaulic joints for all internal water piping connections. desuperheater heat exchanger available as option (50-190 sizes). dynamic setpoint (4-20ma, 0-1V, 0-5V, 0-10V). outdoor air temperature compensation. double set point.
MAIN OPTIONS Modbus protocol kit for BMS. compressor soft starter. Electronic expansion valve. condensing control kit. Electric heater wiring kit. additional heating device wiring kit. Mechanical gauges kit. on board hydrokit. desuperheater.
MAIN ACCESSORIES (field to be installed)
remotez on-off. remote keyboard panel. Sequencer up to 4 units. condensing control kit. Water temperature sensor for dHW tank. outdoor air sensor for weather compensation. Electric heater wiring kit. additional heating device wiring kit. Pressostatic water valve for well application (only for sizes 20 to 45). compressor jacket. Flow switch. Pressure switch. Victaulic to threaded pipe connection. 3 way valve for dHW production. Spring type anti-vibration mounts (only for sizes 50 to 190). Water filter. Valves in/out (only for sizes 20 to 45).
R410A
new
140 141
wQh 50 60 75 90 120 150 170 190COOLING CAPACITy (1) KW 50.2 59.2 76.4 89.0 115.3 144.8 166.3 186.1
input power (compressor) kW 11.4 13.3 16.7 20.3 26.0 32.1 36.8 41.9Heat rejection kW 61.6 72.5 93.1 109.3 141.3 176.9 203.1 228.0
EEr 4.4 4.5 4.6 4.4 4.4 4.5 4.5 4.4ESEEr 6.2 6.2 6.0 6.2 5.8 5.8 6.0 5.7
HEATING CAPACITy (2) 57.2 67.5 85.5 101.2 130.7 162.8 188.3 210.3
input power (compressor) 13.7 16.5 20.3 24.3 31.3 38.5 44.7 50.1coP 4.2 4.1 4.2 4.2 4.2 4.2 4.2 4.2
Power supply 400V/3/50HzStartup type Direct Direct Direct Direct Direct Direct Direct Direct
REFRIGERANT
type R410Anumber of refrigerant circuits 1 1 1 1 1 1 1 1COMPRESSOR
number 2 2 2 2 2 2 2 2type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll
EVAPORATOR
number 1 1 1 1 1 1 1 1 type Plate Plate Plate Plate Plate Plate Plate Plate
CONDENSER
number 1 1 1 1 1 1 1 1type Plate Plate Plate Plate Plate Plate Plate Plate
WATER CONNECTIONS (EVAPORATOR)
type Victaulicinlet/outlet diameter inches 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2
WATER CONNECTIONS (CONDESER)
type Victaulicinlet/outlet diameter inches 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2
WEIGHT
operating weight kg 448 499 551 602 850 983 1058 1162DIMENSIONS
length mm 1210 1210 1210 1210 1210 1210 1210 1210Width mm 850 850 850 850 850 850 850 850
Height mm 1500 1500 1500 1500 1500 1500 1500 1500ACOUSTIC DATA
Sound power level dB(A) 70 70 72 73 78 81 81 81Sound pressure level (3) dB(A) 39 39 41 42 47 50 50 50Sound power level Eln dB(A) 68 68 70 71 76 79 79 79
Sound pressure level (3) Eln dB(A) 37 37 39 40 45 48 48 48
(1) At conditions: evaporator water temperature of 12/7°C and condenser water temperature of 30/35°C.(2) At conditions: evaporator water temperature of 12/7°C°C and condenser water temperature of 40/45°C.(3) Sound pressure level at 10 m.- Values refers to ISO Standard 3744 with parallepiped shape.
142
Commercial Air Conditioning |
143
RWC 170-360WatEr-coolEd cHillEr
cooling capacity: from 161 to 312 kW refrigerant: r407c Sizes: 6
MAIN FeATUReS: 4 scroll compressors/2 independent refrigerant circuits
1 Shell & tube evaporator, 2 Shell & tube condensers
optional desuperheater for partial heat recovery also available with remote condenser (rWr model)
ACOUSTIC OPTIONS: acoustic jacket on each compressor
PRODUCT ADVANTAGES one refrigerant circuit. 4 scroll compressors. refrigerant r407c (rWc only). Shell&tube evaporator and condenser.
Standard configuration: Phase controller. control circuit transformer 400V/230V. Power supply without neutral. Main switch. Evaporator antifreeze electric heater. compressor box.
MAIN OPTIONS Set point timer/clock card. compressor soft starting. Power factor correction capacitors. compressor overload protection. HP & lP manometers. Pressostatic valves (rWc only). compressor jacket. Hydraulic manifolds for condenser single point in/out water connections (rWc only).
MAIN ACCESSORIES remote on/oFF control. ModBus protocol kit for BMS. Bacnet protocol kit for BMS. remote keyboard panel. Master/slaves control up to 4 units maximum. Flow switch. Water filter. remote hydraulic module with water tank, 1 or 2 low or high pressure pump(s), relevant accessories and with or without antifreeze electric heater.
Operating limit fOr Standard unitCOOLING MODE
evaporator Leaving water temperature 6/15°C
evaporator Leaving water temperature with glycol -5/15°C
Condenser Leaving water temperature 30/50°C
-5/15°C
NOTES Operating limits are referred to full load (2 compressors running).Maximum % glycol (ethylenic or propilenic): 40%.
142 143
rwc 170 200 240 260 320 360COOLING CAPACITy (1) KW 160.8 186.5 210.6 263.6 283.7 312.3
input power (compressor) kW 45.8 52.6 56.8 73.0 81.7 90.5Heat rejection kW 206.6 239.1 267.4 336.6 365.4 402.8
EEr 3.51 3.55 3.71 3.61 3.47 3.45COOLING CAPACITy (2) KW 160.8 186.5 210.6 263.6 283.7 312.3
input power (compressor) kW 45.8 52.6 56.8 73.0 81.7 90.5Heat rejection kW 206.6 239.1 267.4 336.6 365.4 402.8Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz
Startup type Direct Direct Direct Direct Direct Direct REFRIGERANT
type R407Cnumber of refrigerant circuits 1 1 1 1 1 1
COMPRESSOR
number 4 4 4 4 4 4type Scroll Scroll Scroll Scroll Scroll Scroll
EVAPORATOR
number 1 1 1 1 1 1 type S&T S&T S&T S&T S&T S&T
CONDENSER
number 2 2 2 2 2 2 type S&T S&T S&T S&T S&T S&T
WATER CONNECTIONS (EVAPORATOR)
type Victaulicinlet/outlet diameter inches 4" 4" 4" 4" 4" 4"
WATER CONNECTIONS (CONDESER)
type Victaulicinlet/outlet diameter inches 2" 2" 2"1/2 2"1/2 2"1/2 2"1/2
REFRIGERANT COMMECTION (RWR)
type To be brazedinlet/outlet diameter inches 1"3/8 -7/78" 1"3/8 -7/78" 1"3/8 -7/78" 1"3/8 -7/78" 1"3/8 -7/78" 1"3/8 -7/78"
WEIGHT
operating weight rWc kg 1294 1339 1470 1586 1616 1630 operating weight rWr kg 1143 1185 1269 1366 1380 1394
DIMENSIONS
length mm 2200 2200 2200 2200 2200 2200 Width mm 800 800 800 800 800 800
Height mm 1820 1820 1820 1820 1820 1820 ACOUSTIC DATA
Sound power level dB(A) 81 82 82 84 85 86 Sound pressure level (3) dB(A) 63.9 64.9 64.9 66.9 67.9 68.9
(1) At conditions: evaporator water temperature of12/7°C and condenser water temperature of30/35°C.(2) At conditions: evaporator water temperature of12/7°C°C and condenser water temperature of40/45°C.(3) Sound pressure level at10 m.- Values refers to ISO Standard3744 with parallepiped shape.
144
Commercial Air Conditioning |
145
SWS 1602-4802WatEr-coolEd cHillEr
cooling capacity: from 272 to 1118 kW refrigerant: r134a Sizes: 15
MAIN FeATUReS: 2 semi-hermetic screw compressors/2 independent refrigerant circuits
1 double Shell & tube evaporator, 2 Shell & tube condensers
optional desuperheater for partial heat recovery also available with remote condenser (SWr model)
ACOUSTIC OPTIONS: Std: Standard unit ln: low noise Eln: Extra low noise
PRODUCT ADVANTAGES two indipendent refrigerant circuit. 2 screw compressors. refrigerant r134a (SWS only). Shell&tube evaporator and condenser
Standard configuration: Set point timer/clock card. Back light display. digital pressure and temperature reading kit. High ambient pressure control. compressor overload protection. data logger. Main switch. Evaporator antifreeze electric heater.
MAIN OPTIONS compressor soft starting. Phase controller. Power factor correction capacitors. Electronic expansion valves. compressor Star/delta starting (sizes 1602 to 2002, standard on other sizes). gSM. HP & lP manometers. compressor suction valves. liquid injection to compressors. compressor oil level pressostat. cu/ni condensers. condensers for well application.
MAIN ACCESSORIES ModBus, lonwork and Bacnet protocol kit for BMS. remote keyboard panel. Master/slaves control up to 4 units maximum. Spring anti-vibration. Flow switch and Water filter. Hydraulic manifolds for condenser single point in/out water connections (SWS only). remote hydraulic module with water tank, 1 or 2 low or high pressure pump(s),
Operating limit fOr Standard unitCOOLING MODE
evaporator Leaving water temperature 5/15°C
evaporator Leaving water temperature with glycol -3/4°C
Condenser Leaving water temperature
+30 to +60°C with tower water
+15 to +30°C with well water
NOTES Operating limits are referred to full load (2 compressors running).Maximum % glycol (ethylenic or propilenic): 40%.
144 145
sws 1602 1902 2202 2212 2352COOLING CAPACITy SWS (1) KW 271.8 362.4 440.0 529.3 564.7
input power (compressor) kW 68.0 82.1 102.0 121.0 129.0 Heat rejection kW 339.8 444.5 542.0 650.3 693.7
EEr 4.00 4.41 4.28 4.36 4.35 ESEEr 4.47 4.93 4.94 4.88 4.87
COOLING CAPACITy SWR (2) KW 271.8 362.4 440.0 529.3 564.7
input power (compressor) kW 63.1 76.3 92.3 112.6 120.4 Heat rejection kW 334.9 438.7 532.4 641.9 685.0
EEr 4.3 4.7 4.8 4.7 4.7 ESEEr 3.51 3.87 3.88 3.87 3.86
Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz Startup type P/W P/W P/W S/D S/D
REFRIGERANT
type R134anumber of refrigerant circuits 2 2 2 2 2
COMPRESSOR
number 2 2 2 2 2type Screw Screw Screw Screw Screw
EVAPORATOR
number 1 1 1 1 1 type S&T S&T S&T S&T S&T
CONDENSER
number 2 2 2 2 2 type S&T S&T S&T S&T S&T
WATER CONNECTIONS (EVAPORATOR)
type Victaulicinlet/outlet diameter inches 5" 6" 8" 6" 6"
WATER CONNECTIONS (CONDESER SWS)
type Female Gas Threadinlet/outlet diameter inches 2"1/2 3" 3" 3" 3"
WEIGHT
operating weight SWS kg 2144 2688 3212 3601 3717 operating weight SWS ln 2454 3000 3611 4001 4117
operating weight SWS Eln 2544 3090 3731 4151 4267 operating weight SWr kg 1845 2190 2675 3057 3169
operating weight SWr ln 2155 2500 3075 3457 3569 operating weight SWr Eln 2245 2590 3195 3607 3719
DIMENSIONS
length mm 3795 3795 4210 4210 4210 Width mm 950 950 1400 1400 1400
Height mm 1910 1910 2050 2050 2050 ACOUSTIC DATA
Sound power level dB(A) 94 94 95 95 95 Sound pressure level (3) dB(A) 75 75 76 76 76 Sound power level ln dB(A) 89 89 90 90 90
Sound pressure level ln (3) dB(A) 70 70 71 71 71 Sound power level Eln dB(A) 81 81 82 82 82
Sound pressure level Eln (3) dB(A) 62 62 63 63 63
(1) At conditions: evaporator water temperature of 12/7°C and condenser water temperature of 30/35°C.(2) At conditions: evaporator water temperature of 12/7°C and condensing temperature of 38°C.(3) Sound pressure levels given at 1 meter from the unit in free field.
146
Commercial Air Conditioning |
147
sws 2502 2652 2802 3012 3202COOLING CAPACITy SWS (1) KW 600.0 639.2 678.4 716.0 784.4
input power (compressor) kW 138.0 145.0 153.0 168.0 182.0 Heat rejection kW 738.0 784.2 831.4 884.0 966.4
EEr 4.34 4.38 4.41 4.25 4.29 ESEEr 4.86 4.90 4.93 4.75 4.80
COOLING CAPACITy SWR (2) KW 600.0 639.2 678.4 716.0 784.4
input power (compressor) kW 128.1 135.4 142.8 156.2 169.7 Heat rejection kW 728.1 774.7 821.2 872.2 954.2
EEr 4.7 4.7 4.7 4.6 4.6 ESEEr 3.86 3.89 3.91 3.78 3.81
Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz Startup type S/D S/D S/D S/D S/D
REFRIGERANT
type R134anumber of refrigerant circuits 2 2 2 2 2
COMPRESSOR
number 2 2 2 2 2type Screw Screw Screw Screw Screw
EVAPORATOR
number 1 1 1 1 1 type S&T S&T S&T S&T S&T
CONDENSER
number 2 2 2 2 2 type S&T S&T S&T S&T S&T
WATER CONNECTIONS (EVAPORATOR)
type Victaulicinlet/outlet diameter inches 6" 6" 6" 6" 8"
WATER CONNECTIONS (CONDESER SWS)
type Female Gas Threadinlet/outlet diameter inches 3" 3" 3" 3" 3"
WEIGHT
operating weight SWS kg 3750 3882 3895 4323 5382 operating weight SWS ln 4150 4282 4295 4723 5882
operating weight SWS Eln 4300 4432 4445 4873 6052 operating weight SWr kg 3179 3307 3317 3727 4780
operating weight SWr ln 3579 3707 3717 4127 5280 operating weight SWr Eln 3729 3857 3867 4277 5450
DIMENSIONS
length mm 4210 4210 4210 4210 4770 Width mm 1400 1400 1400 1400 1400
Height mm 2050 2050 2050 2050 2050 ACOUSTIC DATA
Sound power level dB(A) 95 95 95 95 96 Sound pressure level (3) dB(A) 76 76 76 76 77 Sound power level ln dB(A) 90 90 90 90 91
Sound pressure level ln (3) dB(A) 71 71 71 71 72 Sound power level Eln dB(A) 82 82 82 82 83
Sound pressure level Eln (3) dB(A) 63 63 63 63 64
(1) At conditions: evaporator water temperature of 12/7°C and condenser water temperature of 30/35°C.(2) At conditions: evaporator water temperature of 12/7°C and condensing temperature of 38°C.(3) Sound pressure levels given at 1 meter from the unit in free field.
146 147
sws 3412 3602 4212 4602 4802COOLING CAPACITy SWS (1) KW 841.7 898.9 962.1 1040.2 1118.2
input power (compressor) kW 194.0 206.0 218.7 230.5 242.3 Heat rejection kW 1035.7 1104.9 1180.8 1270.7 1360.5
EEr 4.32 4.36 4.40 4.51 4.61 ESEEr 4.83 4.87 5.17 5.31 5.43
COOLING CAPACITy SWR (2) KW 841.7 898.9 962.1 1040.2 1118.2
input power (compressor) kW 180.5 191.4 218.7 230.5 242.3 Heat rejection kW 1022.2 1090.2 1180.8 1270.7 1360.5
EEr 4.7 4.7 4.4 4.5 4.6 ESEEr 3.84 3.87 3.62 3.72 3.80
Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz Startup type S/D S/D S/D S/D S/D
REFRIGERANT
type R134anumber of refrigerant circuits 2 2 2 2 2
COMPRESSOR
number 2 2 2 2 2type Screw Screw Screw Screw Screw
EVAPORATOR
number 1 1 1 1 1 type S&T S&T S&T S&T S&T
CONDENSER
number 2 2 2 2 2 type S&T S&T S&T S&T S&T
WATER CONNECTIONS (EVAPORATOR)
type Victaulicinlet/outlet diameter inches 8" 8" 8" 8" 8"
WATER CONNECTIONS (CONDESER SWS)
type Victaulicinlet/outlet diameter inches 4" 4" 4" 4" 4"
WEIGHT
operating weight SWS kg 5455 5471 5597 5698 5875 operating weight SWS ln 5955 5971 6097 6198 6375
operating weight SWS Eln 6125 6141 6267 6368 6545 operating weight SWr kg 4790 4800 4920 4980 5153
operating weight SWr ln 5290 5300 5420 5480 5653 operating weight SWr Eln 5460 5470 5590 5650 5823
DIMENSIONS
length mm 4770 4770 4770 4770 4770 Width mm 1400 1400 1400 1400 1400
Height mm 2050 2050 2050 2110 2110 ACOUSTIC DATA
Sound power level dB(A) 96 97 98 98 98 Sound pressure level (3) dB(A) 77 78 79 79 79 Sound power level ln dB(A) 91 92 93 93 93
Sound pressure level ln (3) dB(A) 72 73 74 74 74 Sound power level Eln dB(A) 83 84 85 85 85
Sound pressure level Eln (3) dB(A) 64 65 66 66 66
(1) At conditions: evaporator water temperature of 12/7°C and condenser water temperature of 30/35°C.(2) At conditions: evaporator water temperature of 12/7°C and condensing temperature of 38°C.(3) Sound pressure levels given at 1 meter from the unit in free field.
148
Commercial Air Conditioning |
149
CD 031 to 102cloSE-control air conditioning
Water cooling capacity: from 10 to 32 kW Sizes: 10
CONFIGURATIONS: 3 Water-cooled with Plate Heat Exchanger air-cooled with remote condenser closed circuit water/glycol cooled with remote cooler
AIR DIReCTION upflow (a) downflow (B)
DESCRIPTIONcdseries have been specifically designed and manufactured for close control air conditioning where the almost exclusive handling of sensible heat loads is a fundamental requirement. the typical applications are computer rooms, digital telephone exchanges, switch rooms, weather stations, medical laboratories, cat and Mr scanners, as well as any other application where a sensible heat load must be dissipated without modifying the relative humidity.
PRODUCT ADVANTAGES3 configurations: Packaged unit water cooled, coming from cooling tower, spring water or city water. Self-contained two sections unit, with air-cooled condenser for remote installation. Packaged unit cooled with water-glycol coming from dry-cooler or from water industrial cooling system.
Standard versions Frame aluminium profiles. lining thermo-acustic Polyhurethan Panels. Hermetic scroll compressor. refrigerant filter. air filter g4 efficiency. Supply air centrifugal fan. air Flow switch. Microprocessor control. Safety: air Flow Pressure Switch and refrigerant High low Pressure. drain Pan Stainless Steel.
MAIN OPTIONS differential pressure switch. Water leakage alarm. Fire alarm. Electric reheating coil. Hot water reheating coil. Hot gas reheating coil. three way valve. Steam humidifier. dehumidification system. Fresh air intake kit. rear return air. Supply air centrifugal fan. air delivery plenum. Base frame. non-return damper. Speed control. temperature + humidity microprocessor. clock module. advanced microprocessor.
MAIN ACCESSORIES advanced microprocessor for temperature + humidity control. air filter. Pressure actuated water valve. Special coils. Special refrigerant r134a. internal lining. Sandwich panels. Serial output card rs 485.
Operating limit fOr Standard unitCOOLING MODE
Inlet air conditions (HR) 18/30°C
Hydraulic pressure max 600 kPa
148 149
cd 31 41 51 61 71 91 101 72 82 102CONFIG.1
total cooling capacity (1) kW 10.60 13.40 17.00 21.20 23.50 29.40 32.90 21.60 25.90 32.10Sensible cooling capacity (1) kW 9.70 12.30 15.10 19.50 21.60 26.10 30.10 19.60 23.50 29.50
Power input kW 2.32 2.78 3.57 4.72 5.31 6.49 7.45 4.64 5.62 7.14CONFIG.2.6
total cooling capacity (2) kW 10.00 12.80 15.30 20.50 22.10 27.60 31.30 21.00 23.50 30.80Sensible cooling capacity (2) kW 9.30 12.00 13.90 19.30 20.50 25.20 29.00 19.50 23.50 28.30
Power input kW 2.80 3.35 4.26 5.64 6.33 7.76 8.92 5.56 6.76 8.52SUPPLy FAN
nominal air flow m³/s 0.75 1.11 1.11 1.67 1.67 1.94 2.36 1.67 1.67 2.36External static pressure Pa 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0
Power input kW 0.4 0.7 0.7 0.9 0.9 1.4 1.4 0.8 0.8 1.4COMPRESSOR
number 1 1 1 1 1 1 1 2 2 2nominal power HP 3.5 4.0 5.0 6.5 7.5 9.0 10.0 2x3.5 2x4 2x5
REFRIGERANT
type R407Crefrigerant circuits 1 1 1 1 1 1 1 2 2 2
AIR COOLED CONDENSER
Model CN-030 CN-050 CN-050 CN-075 CN-075 CN-100 CN-100 2xCN-030 2xCN-050 2xCN-050SOUND PRESSURE LEVEL
up-flow dB(A) 52 55 55 55 56 57 58 55 55 57down-flow (3) dB(A) 48 51 51 51 52 33 54 51 51 53
DIMENSIONS
length 650 840 840 1238 1238 1428 1618 1238 1238 1618Width 650 650 650 650 650 650 650 650 650 650
Height 1970 1970 1970 1970 1970 1970 1970 1970 1970 1970OPERATING WEIGHT
configuration 1.6 kg 160.0 180.0 220.0 300.0 360.0 380.0 440.0 320.0 340.0 450configuration 2 kg 155.0 175.0 215.0 290.0 350.0 360.0 420.0 290.0 310.0 420
Capacities referred to:(1) Room air conditions +24°C/50% RH. Condensing water temperature +15/35°C.(2) Room air conditions +24°C/50% RH. external air temperature +32°C. Dry-cooler water temperature +35/40°C.(3) Sound pressure level measured at 2 metres from the machine, 1 metre from the ground, in free field conditions.
The fan power input has not been substracted from the capacities indicated above. Heating capacity based on air temperature of 15°C and water temperature of 90/70°C (coil at the discharge side). Fan performance curves: consult Technical Manual (eDM).
150
Commercial Air Conditioning |
151
MD 061 to 302cloSE-control air conditioning
Water cooling capacity: from 20 to 103 kW Sizes: 14
CONFIGURATIONS: 3 Water-cooled with Plate Heat Exchanger air-cooled with remote condenser closed circuit water/glycol cooled with remote cooler
AIR DIReCTION upflow (a) downflow (B)
DESCRIPTIONMd series have been specifically designed and manufactured for close control air conditioning where the almost exclusive handling of sensible heat loads is a fundamental requirement. the typical applications are computer rooms, digital telephone exchanges, switch rooms, weather stations, medical laboratories, cat and Mr scanners, as well as any other application where a sensible heat load must be dissipated without modifying the relative humidity.
PRODUCT ADVANTAGES3 configurations: Packaged unit water cooled, coming from cooling tower, spring water or city water. Self-contained two sections unit, with air-cooled condenser for remote installation. Packaged unit cooled with water-glycol coming from dry-cooler or from water industrial cooling system.
Standard versions Frame aluminium profiles. lining thermo-acustic Polyhurethan Panels. Hermetic scroll compressor. refrigerant filter. air filter g4 efficiency. Supply air centrifugal fan. air Flow switch. Microprocessor control. Safety: air Flow Pressure Switch and refrigerant High low Pressure. drain Pan Stainless Steel.
MAIN OPTIONS differential pressure switch. Water leakage alarm. Fire alarm. Electric reheating coil. Hot water reheating coil. Hot gas reheating coil. three way valve. Steam humidifier. dehumidification system. Fresh air intake kit. rear return air. Supply air centrifugal fan. air delivery plenum. Base frame. non-return damper. Speed control. temperature + humidity microprocessor. clock module. advanced microprocessor.
MAIN ACCESSORIES advanced microprocessor for temperature + humidity control. air filter. Pressure actuated water valve. Special coils. Special refrigerant r134a. internal lining. Sandwich panels. Serial output card rs 485.
Operating limit fOr Standard unitCOOLING MODE
Inlet air conditions (HR) 18/30°C
Hydraulic pressure max 600 kPa
150 151
md 061 071 091 101 131 151 82 102 132 152 182 202 262 302CONFIG.1
total cooling capacity (1) kW 20.50 26.40 31.40 36.10 45.10 55.10 29.00 35.20 47.20 52.60 63.90 69.70 88.80 102.90Sensible cooling capacity (1) kW 18.60 24.80 28.50 32.70 42.80 50.60 27.40 32.30 43.30 50.00 58.70 63.30 83.10 93.80
Power input kW 3.90 5.10 6.20 7.10 9.00 10.80 5.40 6.80 9.00 10.20 12.40 14.20 18.00 21.60CONFIG.2.6
total cooling capacity (2) kW 18.30 24.30 28.40 32.90 41.30 50.40 26.30 32.30 42.60 48.00 57.60 64.10 80.70 94.30Sensible cooling capacity (2) kW 17.40 23.00 26.30 30.50 38.50 47.80 24.20 29.70 39.50 45.00 54.50 59.20 76.60 85.60
Power input kW 4.90 6.30 7.80 8.70 11.10 13.50 6.80 8.20 11.20 12.60 15.60 17.40 22.20 27.00SUPPLy FAN
nominal air flow m³/s 1.39 2.08 2.08 2.5 3.61 3.89 2.08 2.5 3.61 3.89 4.44 4.44 6.94 6.94External static pressure Pa 250.0 300.0 300.0 200.0 100.0 250.0 300.0 200.0 100.0 250.0 250.0 250.0 250.0 250.0
Power input kW 1.1 1.6 1.6 1.7 2x1.4 2x1.4 1.6 1.7 2x1.4 2x1.4 2x1.5 2x1.5 2x2.9 2x2.9COMPRESSOR
number 1 1 1 1 1 1 2 2 2 2 2 2 2 2REFRIGERANT
type R407Crefrigerant circuits 1 1 1 1 1 1 2 2 2 2 2 2 2 2
AIR COOLED CONDENSER
Model CN060 CN075 CN100 CN100 CN120 CN150 2xCN050 2xCN050 2xCN075 2xCN075 2xCN100 2xCN100 2xCN120 2xCN150SOUND PRESSURE LEVEL
up-flow dB(A) 55 62 62 61 64 66 62 61 64 65 67 67 67 68down-flow (3) dB(A) 51 58 58 57 60 60 58 57 60 61 63 63 63 64
DIMENSIONS
length 860 1258 1258 1448 1885 2265 1258 1448 1885 2265 2265 2265 2853 2853Width 860 860 860 860 860 860 860 860 860 860 860 860 860 860
Height 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980OPERATING WEIGHT
configuration 1.6 kg 280 340 350 400 520 640 370 420.0 540.0 660 720.0 870.0 960.0 980.0configuration 2 kg 270 330 340 380 495 610 360 400.0 515.0 630 685.0 830.0 920.0 940.0
Capacities referred to:Room air conditions: +24°C/50% RH.(1) Condensing water temperature: +15/35°C.(2) external air temperature: +32°C.(3) Sound pressure level measured at 2 metres from the machine, 1 metre from the ground, in free field conditions.
The fan power input has not been substracted from the capacities indicated above.
152
Commercial Air Conditioning |
153
CW 021 to 152cloSE-control air conditioning
Water cooling capacity: from 15 to 200 kW Sizes: 12
CONFIGURATIONS chiller Water
AIR DIReCTION upflow (a) downflow (B)
DESCRIPTIONcW series have been specifically designed and manufactured for close control air conditioning where the almost exclusive handling of sensible heat loads is a fundamental requirement.the typical applications are computer rooms, digital telephone exchanges, switch rooms, weather stations, medical laboratories, cat and Mr scanners, as well as any other application where a sensible heat load must be dissipated without modifying the relative humidity.
PRODUCT ADVANTAGES3 configurations: Packaged unit water cooled, coming from cooling tower, spring water or city water. Self-contained two sections unit, with air-cooled condenser for remote installation. Packaged unit cooled with water-glycol coming from dry-cooler or from water industrial cooling system.
Standard versions Frame aluminium profiles. lining thermo-acustic Polyhurethan Panels. Evaporatoring coil. 3Way Valve. air filter g4 efficiency. Supply air centrifugal fan. air Flow switch. Microprocessor control. Safety: air Flow Pressure Switch and refrigerant High low Pressure. drain Pan Stainless Steel.
MAIN OPTIONS differential pressure switch. Water leakage alarm. Fire alarm. Electric reheating coil. Hot water reheating coil. Hot gas reheating coil. three way valve. Steam humidifier. dehumidification system. Fresh air intake kit. rear return air. Supply air centrifugal fan. air delivery plenum. Base frame. non-return damper. Speed control. temperature + humidity microprocessor. clock module. advanced microprocessor. air filter having efficiency f5 or f7. Special coils. internal lining. Sandwich panels. Serial output card rs 485.
Operating limit fOr Standard unitCOOLING MODE
Inlet air conditions (HR) 18/30°C
Hydraulic pressure max 600 kPa
152 153
cw 21 31 41 51 61 42 52 62 82 102 112 152total cooling capacity (1) kW 15.10 25.80 35.50 49.80 57.80 39.40 49.20 60.80 83.00 94.80 110.80 152.00
Sensible cooling capacity (1) kW 13.80 22.60 30.20 42.70 51.10 33.50 41.80 49.70 67.90 78.00 95.80 128.90SUPPLy FAN
nominal air flow m³/s 1.11 1.45 1.81 2.78 3.33 2.36 2.72 3.75 4.86 5.56 6.94 10External static pressure Pa 250.0 150.0 100.0 200.0 120.0 200.0 100.0 100.0 200.0 250.0 200.0 200.0
Power input kW 1.1 1.2 1.4 2x1.2 2x1.5 1.6 2.0 2x1.4 2x1.6 2x2.6 2x3.5 3x3.4WATER PRESSURE DROP
total water pressure drop kPa 45 65 52 73 68 56 44 78 55 67 80 91SOUND PRESSURE LEVEL
up-flow dB(A) 54.5 56 58.5 59 61.5 58 60 62 65 63 64 67 down-flow (3) dB(A) 50.5 52 54.5 55 57.5 54 56 58 61 59 60 63
DIMENSIONS
length mm 650 840 1238 1428 1618 860 1258 1448 1885 1885 2265 2853Width mm 650 650 650 650 650 860 860 860 860 860 860 860
Height mm 1970 1970 1970 1970 1970 1980 1980 1980 1980 1980 1980 1980OPERATING WEIGHT
configuration kg 160 210 280 330 380 270 330 380.0 470.0 540 600.0 720.0
Capacities referred to:Room air conditions: +24°C/50% RH.(1) Condensing water temperature: +15/35°C.(2) external air temperature: +32°C.(3) Sound pressure level measured at 2 metres from the machine, 1 metre from the ground, in free field conditions.
The fan power input has not been substracted from the capacities indicated above.
154
Commercial Air Conditioning |
155
Westherm 35 to 70cHillEd WatEr ProPEllEr Fan unit HEatEr
cooling water capacity: from 3 to 33 kW Heating water capacity: from 4 to 143 kW Heating steam capacity: from 15 to 302 kW Sizes: 6 airflow: from 608 to 13.538 m³/h
DESCRIPTIONthe WEStHErM propeller fan type unit heaters are intended for heating, cooling or air mixing applications in service, commercial and industrial sectors.
the WEStHErM range is composed of 6 sizes and available in 3 versions: Hot water/steam, chilled water (only with PHM version), air blower.
and could be in 2 series according to the motor type and according to the size: PHM series equipped with 5-speed single phase motor, PHt series equipped with single speed three phase motor.
thanks to a large choice of air diffusers, special arrangements, options and accessories, the WEStHErM range allows to meet all applications encountered.
PRODUCT ADVANTAGESPHT series unit heaters: Propeller fan with wide aluminium blades. impeller special profile provides optimum air volume/pressure performance and assures a low noise level. Fan is statically and dynamically balanced. the air inlet side is designed to offer minimum pressure drop and noise level.
PHM series unit heaters: the units of this series are equipped with single phase propeller fan motor (asynchronous type, internal rotor, ball bearings, aluminium casing) and with an autotransformer supplied as standard to ensure 5 ventilation speeds. the propellers (5 or 7 blades according to the sizes) are made of composite material reinforced by 30% of glass fibber. the PHM series unit heaters are fitted with a fan guard (/!\ standard only on PHM version), supplied as standard, made of steel wire coated with black polyester painting. High acoustic performance, low energy consumption, compactness and air flow stability despite coil clogging constitute the main features of these new fans.
MAIN OPTIONSAir blowers: two-speed motor for PHt units only. Maintenance and repair switch for PHM and PHt units (single and two speeds). aluminium propellers for PHM series units. Epoxy painting on casing.
Chilled water version: Maintenance and repair switch. aluminium propellers for PHM series units.
Hot water/steam version: cupro-nickel coils, for high temperature water or steam applications. room thermostat. two-speed motors (except size 35) for PHt unit heaters only. air filter to be fitted inside or outside the inlet cubic casing. Special mounting kits (Val, VaF, VaK, VaJF, VagK, VagJF, VagZ, VaBgZ, VaBF, HaBgZ).
Maintenance and repair switch for PHM and PHt unit heaters (single and two speeds). aluminium propellers for PHM unit heaters. Epoxy painting on casing.
MAIN ACCESSORIES Wall mounting kit. Proximity switch factory mounted. radiation screen (for PHM model with composite propellers).
Air blowers: air diffusers Hn, HP (except for sizes 70) and Ho (except for sizes 35 & 70). Fan guard for PHt units only (in standard on PHM).
Chilled water version: double deflection n type diffuser. Fan guard for PHt units only (in standard on PHM).
Hot water/steam version: double deflexion n type diffuser. HP, Ho, Vr type diffuser. Fan guard for PHt unit heaters only (in standard on PHM). room thermostat. Special mounting kits (Val, VaF, VaK, VaJF, VagK, VagJF, VagZ, VaBgZ, VaBF, HaBgZ).
Operating limit fOr Standard unit chilled version only on vertical configuration for specific environment precoated metal sheet not adapted (corrosion risk): ask for Epoxy version.
154 155
westherm 35 45 50 55 65 70PHM 230V - 1PH - 50 Hz - 5 SPEEDS
Airflow min. (Speed 1 with 3rows coil) m³/h 284 608 1063 1299 1653 2320Airflow max. (Speed 5 with 1row coil) m³/h 2048 3748 6010 7623 9985 13538nominal speed rpm 1370 1280 1400 1390 1300 860Power kW 0.16 0.37 0.7 0.96 1.36 1.14Current A 0.8 1.9 3.2 4.6 6.6 5.3Class and IP Class F/IP 55PHT 230/400V - 3PH - 50 Hz - 900 RPM 35 45 50 55 65 70
Airflow min. (900rpm with 3rows coil) m³/h 1030 2620 3820 4950 6980 13780Sound pressure level at 5m dB(A) 46 53 57 61 63 N/APower kW 0.037 0.25 0.25 0.25 0.37 0.75Current A 0.46/0.27 1.44/0.83 1.44/0.83 1.44/0.83 2.08/1.19 3.65/2.1Class and IP F/54 F/55PHT 230/400V - 3PH - 50 Hz - 1400 RPM 35 45 50 55 65 70
Airflow max. (1400rpm with 1rows coil) m³/h 1840 4820 6750 8940 11960 N/ASound pressure level at 5m dB(A) 46 53 57 61 63 N/APower kW 0.038 0.25 0.55 0.55 0.75 N/ACurrent A 0.4/0.23 1.41/0.81 2.46/1.42 2.46/1.42 3.22/1.86 N/AClass and IP F/54 F/55 N/ACHILLED VERSION - PERFORMANCE WITH A COOLING COIL 3 ROWS - PHM VERSION (230V - 1PH - 50Hz) ONLy
Airflow speed 1 m³/h N/A 608 N/A 1299 1653 N/ASound pressure level at 5m (acc. NF-S 31-021) for speed 1 dB(A) N/A 19 N/A 33 42 N/ACooling capacity speed 1 (air: 25°C/50% - Water in: 7/12°C) kW N/A 2.88 N/A 5.65 7.22 N/ACooling capacity speed 1 (air: 35°C/50% - Water in: 7/12°C) kW N/A 7.36 N/A 16.09 19.16 N/AAirflow speed 2 m³/h N/A 1149 N/A 2452 3123 N/ASound pressure level at 5m (acc. NF-S 31-021) for speed 2 dB(A) N/A 33 N/A 42 50 N/ACooling capacity speed 2 (air: 25°C/50% - Water in: 7/12°C) kW N/A 3.82 N/A 7.47 9.48 N/ACooling capacity speed 2 (air: 35°C/50% - Water in: 7/12°C) kW N/A 10.53 N/A 23.49 27.7 N/AAirflow speed 3 (maximum speed allawed) m³/h N/A 1726 N/A 3684 4691 N/ASound pressure level at 5m (acc. NF-S 31-021) for speed 3 dB(A) N/A 42 N/A 45 53 N/ACooling capacity speed 3 (air: 25°C/50% - Water in: 7/12°C) kW N/A 4.68 N/A 3.82 11.92 N/ACooling capacity speed 3 (air: 35°C/50% - Water in: 7/12°C) kW N/A 12.71 N/A 28.01 32.88 N/AHOT WATER VERSION - PHM OR PHT VERSION
Airflow min. (Speed 1 with 3row coil) m³/h 1440 3090 5400 6600 8398 11780Heating capacity for air 12°C/90% - Water 90/70% kW 23.01 43.08 67.92 86.21 110.59 143.7Heating capacity for air 12°C/90% - Water 80/60% kW 19.23 35.31 55.93 71.53 90.87 116.65Heating capacity for air 12°C/90% - Water 60/40% kW 11.47 19.41 31.5 41.59 50.61 61.56Airflow max. (Speed 5 with 1row coil) m³/h 2048 3748 6010 7623 9985 13538Heating capacity for air 12°C/90% - Water 90/70% kW 14.18 29.83 44.05 N/A 74.8 96.34Heating capacity for air 12°C/90% - Water 80/60% kW 10.99 24.1 35.9 N/A 60.7 77.53Heating capacity for air 12°C/90% - Water 60/40% kW 4.82 12.54 19.4 26.45 32.21 39.74STEAM WATER VERSION - PHM OR PHT VERSION
Airflow min. (Speed 1 with 3row coil) m³/h 1440 3090 5400 6600 8398 11780Heating capacity for air 12°C/90% - Vapor 2 bars kW N/A 64.05 N/A N/A N/A N/AHeating capacity for air 12°C/90% - Vapor 4 bars kW N/A 78.59 N/A N/A 197.59 N/AHeating capacity for air 12°C/90% - Vapor 6 bars kW 23.01 43.08 67.92 86.21 110.59 143.7Airflow max. (Speed 5 with 1row coil) m³/h 2048 3748 6010 7623 9985 13538Heating capacity for air 12°C/90% - Vapor 2 bars kW 16.58 29.84 N/A N/A N/A N/AHeating capacity for air 12°C/90% - Vapor 4 bars kW 20.47 36.86 N/A N/A N/A 118.05Heating capacity for air 12°C/90% - Vapor 6 bars kW 14.18 29.83 44.05 N/A 74.8 96.34
Diffuser VN Diffuser HO Diffuser VM Diffuser HN Diffuser VR Diffuser HP
Horizontal discharge Horizontal discharge Horizontal discharge Vertical discharge Air curtain discharge Vertical discharge
156
Commercial Air Conditioning |
157
Reliability with PRoven technology
Fan speed controller
CAC controller
Scroll hermetic compressor + crankcase heater
Electro-mechanical controller
Fan with variable pitch pulley
Remote controller
DIRECT EXPANSION RANGE
19/83 kW 43/85 kW 92/151 kW 154/ 347 kW
CDN AQC AQVC VLC XAR + UC
DK DN CAO XAO
dir
eCt
expa
nsi
on
R
An
Ge power & robustness in all conditions
AIR COOLED CONDENSING UNIT
AIR COOLED SPLIT UNIT
WATER COOLED CONDENSING
UNIT
R407C
SCROLL
NONE
R410A
SCROLL
Electronic control
R410A
SCROLL
Electronic control
R410A
SCROLL
Electronic control
10/55 kW 12/83 kW 2/5 kW 8/46 kW
R407C R407C R407C R407C
RECIPRO-CATING SCROLL SCROLL RECIPRO-
CATING
Electro- mechanical
CAC controller
Electro- mechanical
Electro- mechanical
Standard protective devices: Flow switch/pressostat on hydraulic circuit HP pressure switch LP pressure switch Fuse holder
156 157
PRODUCTION SITES OPTIMIZED TO SATISFY YOUR NEEDS
REFRIGERANT OZONE FRIENDLY Lean Manufacturing
Kaizen concept Built-to-order
a range specially developped for roBustness:
Weather resistant casing made of heavy gauge galvanized steel coated with powder-based epoxy paint RAL 9001.
Wide operating limits. High and low operating temperature with fan speed controller.
Easy access to technical compartment and to main components.
Compressor fitted with crankase heater and mounted on rubber pads.
And flexibility with several versions to fit any of your requirements such as acoustical with:
- Basic Low Noise version- Extra Low Noise version- Special Inverter Fan version
Or refrigerant:- BAZ as standard version- BAC: BAZ with suction accumulator- BAL: BAC with liquid receiver
R410A
AQCCDN
158
Commercial Air Conditioning |
159
DK DNair-to-air SPlit SyStEM - cooling and HEating ModE
cooling capacity: from 12 to 83 kW Heating capacity: from 12.4 to 83.8 kW refrigerant: r407c Sizes: 12
CONFIGURATIONS: Packaged Split system
PRODUCT ADVANTAGES Weather resistant casing with external panels coated with powder-based epoxy paint colour ral 9001. indoor centrifugal fan units for duct netwrok connection. High static pressure available. Multi-position architecture for horizontal or vertical mounting (acc. to models). compact, top discharge outdoor fan units. low noise axial fan. Scroll compressor with crankcase heater. Electrical, refrigeration and thermal protection devices. Phase controller. External HP and lP pressure taps. Frame and air filter supplied.
MAIN OPTIONS Factory-fitted low ambient temperature control to ensure cooling operation down to -10°c outdoor temperature (all-season).
MAIN ACCESSORIES Synthetic air filter. Electric heater. Programmable controlller rcW2 to control up to 15 units with independent set points and programming.
Operating limit fOr Standard unitCOOLING MODE
Minimum indoor air temperature 21°C DB/15°C WB
Maximum indoor air temperature 32°C DB/23°C WB
Minimum outdoor air temperature/with all-season kit 15°C DB/-10°C
Maximum outdoor air temperature 46°C DB
HEATING MODE
Maximum indoor air temperature 27°C DB
Minimum outdoor air temperature -10°C
Maximum outdoor air temperature 24°C DB/18°C WB
158 159
dK-dn 125-155-185INDOOR UNIT DK 125 DK-V 125 DK 155 DK-V 155 DK 185OUTDOOR UNIT Cool only DN 125 DN 125 DN 155 DN 155 DN 185OUTDOOR UNIT Reversible DN 125RC DN 125RC DN 155RC DN 155RC DN 185RCCAPACITIES
coolingcooling capacity kW 12.0 12.0 14.5 14.5 17.5
Power input kW 4.9 4.9 5.8 5.8 6.9EEr 2.4 2.4 2.5 2.5 2.5
HeatingHeating capacity kW 12.4 12.4 15.7 15.7 18
Power input kW 4.8 4.8 5.8 5.8 6.4coP 2.6 2.7 2.7 2.8 2.7
INDOOR UNIT
VEntilationavailable static pressure Pa 160 180 130 110 200
nominal airflow m³/h 2100 2100 2850 2850 3500airflow range (min/max) m³/h 1600/2400 1600/2400 2300/3100 2300/3100 2800/3900
Sound lEVElS Sound power level dB(A) 72 69 73 72 75
diMEnSionSlxWxH mm 1150x745x340 1050x972x350 1350x745x340 1254x972x350 1350x745x400
Mounting H/V H H/V H H/V HWEigHt unit weight kg 58 69 65 77 98
OUTDOOR UNIT
VEntilationnumber of fan 1 1 1 1 1
nominal airflow m³/h 5400 5400 9000 9000 9000 Sound lEVElS Sound power level dB(A) 82 82 82 82 79
diMEnSionS lxWxH mm 746x746x 909 746x746x 909 900x800x1060 900x800x1060 900x800x1060 WEigHt unit weight kg 140 140 150 150 164
POWER SUPPLy
Power supply 400V/3P/50 HzPower supply side Outdoor
PIPE LINE
Suction pipe diameter < 20m inches 3/4" 3/4" 7/8" 7/8" 7/8"Suction pipe diameter > 20m inches 3/4" 3/4" 3/4" 3/4" 3/4"
liquid pipe diameter < 20m inches 1/2" 1/2" 1/2" 1/2" 5/8"liquid pipe diameter > 20m inches 1/2" 1/2" 1/2" 1/2" 5/8"
Max lenght m 50 50 50 50 50Max height m 50 50 50 50 50
PRODUCT CODE
indoor unitSmall ventilation Code 7SP051153 7SP051152 7SP051154 7SP051151 7SP051069High ventilation Code - - - - -
outdoor unit - cool only
standard Code 7SP111061 7SP111061 7SP111054 7SP111054 7SP111055With all-season control Code 7SP111081 7SP111081 7SP111082 7SP111082 7SP111080
outdoor unit - reversible
standard Code 7SP111062 7SP111062 7SP111056 7SP111056 7SP111057With all-season control Code 7SP111079 7SP111079 7SP111083 7SP111083 7SP111084
ACCESSORIES
Electric heater
kW 6 9 6 10,5 12Code 7ACEl1093 7ACEl1208 7ACEl1096 7ACEl1209 7ACEl1184kW 8,1 - 8,1 - -Code 7ACEl1094 7ACEl1097
remote control rcW2 Code 7ACEl1221air filter Code 7ACVF0077 7ACVF0077 7ACVF0078 7ACVF0078 -
160
Commercial Air Conditioning |
161
dK-dn 185-205-255-305-405INDOOR UNIT DK 205 DK 255 DK 305 DK 405 M DK 405OUTDOOR UNIT Cool only DN 205 DN 255 DN 305 DN 405 M DN 405OUTDOOR UNIT Reversible DN 205RC DN 255RC DN 305RC DN 405MRC DN 405RCCAPACITIES
coolingcooling capacity kW 19.1 21.0 28.5 36.0 37.5
Power input kW 7.3 8.6 11.5 13.9 14.4EEr 2.6 2.4 2.5 2.6 2.6
HeatingHeating capacity kW 18.3 21 27.3 36.0 36.5
Power input kW 6.7 7 9.3 13.3 11.9coP 3 2.9 2.7 3 2.9
INDOOR UNIT
VEntilationavailable static pressure Pa 210 210 190 180 180
nominal airflow m³/h 4500 4680 5760 7560 7560airflow range (min/max) m³/h 3600/5000 3800/5100 4600/6300 6000/8200 6000/8200
Sound lEVElS Sound power level dB(A) 84 84 78 83 83
diMEnSionSlxWxH mm 1352x1060x400 1692x1060x400 1690x1005x676 1690x1005x676 1690x1078x676
Mounting H/V H H H H HWEigHt unit weight kg 98 100 150 160 160
OUTDOOR UNIT
VEntilationnumber of fan 1 1 1 1 1
nominal airflow m³/h 9000 9000 9000 16000 2x9000 Sound lEVElS Sound power level dB(A) 78 78 86 83 87
diMEnSionS lxWxH mm 900x800x1060 900x800x1060 1003xx1003x1094 1004x1004x1257 1708x1123x972 WEigHt unit weight kg 164 164 187 247 317
POWER SUPPLy
Power supply 400V/3P/50 HzPower supply side Outdoor
PIPE LINE
Suction pipe diameter < 20m inches 1-1/8" 1-1/8" 7/8" 1-3/8" 7/8"Suction pipe diameter > 20m inches 1-1/8" 1-1/8" 1-1/8" 1-3/8" 7/8"
liquid pipe diameter < 20m inches 1/2" 1/2" 5/8" 5/8" 1/2"liquid pipe diameter > 20m inches 5/8" 5/8" 5/8" 5/8" 5/8"
Max lenght m 30 30 30 30 30Max height m 15 15 15 10 15
PRODUCT CODE
indoor unitSmall ventilation Code 7SP051141 7SP051142 7SP051143 7SP051155 7SP051144High ventilation Code - - 7SP051147 7SP051156 7SP051148
outdoor unit - cool only
standard Code 7SP112013 7SP112014 7SP112015 7SP112131 7SP112016With all-season control Code 7SP112082 7SP112083 7SP112084 7SP112131 7SP112085
outdoor unit - reversible
standard Code 7SP112019 7SP112020 7SP112021 7SP112132 7SP112022With all-season control Code 7SP112088 7SP112089 7SP112090 Included 7SP112091
ACCESSORIES
Electric heater
kW 12 18 18 21 21Code 7ACEl1186 7ACEl1189 7ACEl1176 7ACEl1177 7ACEl1177kW - - - - -Code
remote control rcW2 Code 7ACEl1221air filter Code 7ACVF0124 7ACVF0124 7ACVF0125 7ACVF0125 7ACVF0125
160 161
dK-dn 405-505-605-755-905INDOOR UNIT DK 505 DK 605 DK 755 DK 905OUTDOOR UNIT Cool only DN 505 DN 605 DN 755 DN 905OUTDOOR UNIT Reversible DN 5RC05RC DN 605RC DN 75RC5RC DN 905RCCAPACITIES
coolingcooling capacity kW 44.0 56.0 69.1 83.0
Power input kW 16.7 22.5 26.9 33.0EEr 2.6 2.5 2.6 2.5
HeatingHeating capacity kW 42.0 57.5 71.0 83.8
Power input kW 14.4 22.9 26.4 32.4coP 2.5 2.7 2.6 2.5
INDOOR UNIT
VEntilationavailable static pressure Pa 520 320 330 460
nominal airflow m³/h 9360 9720 12000 14300airflow range (min/max) m³/h 7500/10300 7780/11000 9600/13200 11440/15730
Sound lEVElS Sound power level dB(A) 84 85 87 87
diMEnSionSlxWxH mm 2100x1078x703 2100x1078x703 2208x949x795 2208x949x945
Mounting H/V H H H HWEigHt unit weight kg 205 209 266 282
OUTDOOR UNIT
VEntilationnumber of fan 2 2 2 2
nominal airflow m³/h 2x9000 2x9000 2x16000 2x16000 Sound lEVElS Sound power level dB(A) 86 86 87 87
diMEnSionS lxWxH mm 1708x1123x1171 1708x1123x1171 2213x1345x1309 2213x1345x1459 WEigHt unit weight kg 378 405 559 592
POWER SUPPLy
Power supply 400V/3P/50 HzPower supply side Outdoor
PIPE LINE
Suction pipe diameter < 20m inches 7/8" 1-1/8" 1-1/8" 1-3/8"Suction pipe diameter > 20m inches 7/8" 1-1/8" 1-3/8" 1-3/8"
liquid pipe diameter < 20m inches 1/2" 1/2" 5/8" 5/8"liquid pipe diameter > 20m inches 5/8" 5/8" 5/8" 5/8"
Max lenght m 30 30 30 30Max height m 15 15 15 15
PRODUCT CODE
indoor unitSmall ventilation Code 7SP051145 7SP051146 7SP051122 7SP051123High ventilation Code 7SP051149 7SP051150 - -
outdoor unit - cool only
standard Code 7SP112017 7SP112018 7SP112137 7SP112146With all-season control Code 7SP112086 7SP112087 Included Included
outdoor unit - reversible
standard Code 7SP112023 7SP112024 7SP112138 7SP112147With all-season control Code 7SP112092 7SP112093 Included Included
ACCESSORIES
Electric heater
kW 30 30 30 30Code 7ACEl1178 7ACEl1178 7ACEl1340 7ACEl1340kW - - - -Code
remote control rcW2 Code 7ACEl1221air filter Code 7ACVF0126 7ACVF0126 - -
162
Commercial Air Conditioning |
163
CAOWatEr conSolE - cooling only
cooling capacity: from 2.3 to 4.7 kW refrigerant: r407c Sizes: 3
CONFIGURATIONS: Monobloc system
PRODUCT ADVANTAGES ideal solution for premises where it is impossible to install an outdoor unit. Easy installation and maintenance. Public or recycled water operation. Modulating regulation valve for reducing water consumption. Possibility of fresh air intake. rotary compressor. reusable air filters.
MAIN ACCESSORIES remote control. Electric heater.
Operating limit fOr Standard unitCOOLING MODE
Minimum air temperature 15°C DB/ 10°C WB
Maximum air temperature 32°C DB/ 23°C WB
Minimum water temperature (wasted/recycled) +10°C/20°C
Maximum water temperature (wasted/recycled) +30°C/44°C
162 163
cao 230 cao 370 cao 580CAPACITIES
coolingcooling capacity kW 2,3 3,0 4,7
Power input kW 0,66 0,85 1,30EEr 3,4 3,5 3,6
VENTILATION
airflow range (min/max) m³/h 450/550 450/550 725/880Fresh airflow m³/h 60 60 80
HyDRAULIC
Water flow l/h 130 170 270 SOUND LEVELS
Sound pressure level (4m) (min/max) dB(A) 37/40 38/41 41/43POWER SUPPLy
Power supply 230/1P/50 Hz DIMENSIONS
lx WxH mm 1030x226x620 1030x226x620 1390x226x620 WEIGHT
unit weight kg 48 49 69
PRODUCT CODE
Code 7CW011016 7CW011017 7CW011018
ACCESSORIES
Electric heaterkW 2 2 3Code 7ACEl0006 7ACEl0006 7ACEl0007
remote control Code 7ACEl0039 7ACEl0039 7ACEl0039
164
Commercial Air Conditioning |
165
x ARVErtical air caBinEt - cooling only
cooling capacity: from 9.7 to 55 kW refrigerant: r407c Sizes: 6
CONFIGURATIONS: Split system
PRODUCT ADVANTAGES Easy installation and maintenance. Split system with outdoor condenser fan unit. treated air distribution to premise by plenum or duct network.
adjustable available static pressure. temperature control by thermostat. Electrical, refrigeration and thermal protection devices.
MAIN OPTIONS room thermostat. Electric heater. Hot water heating coil. “all season” system (cooling mode operation down to outdoor temperatuire of -10°c). remote fault reporting. Plenum. duct flange. Valves. Pipe link.
Operating limit fOr Standard unitINDOOR UNIT
Minimum air temperature (room/intake/around unit) 21°C DB/15°C WB
Maximum air temperature (room/intake/around unit) 32°C DB/23°C WB
OUTDOOR UNIT
Minimum air temperature/with all-season kit 15°C DB/-10°C
Maximum air temperature 46°C DB
164 165
x ar indoor unit x 1100 ar x 1900 ar x 2450 ar x 3250 ar x 4650 ar x 6450 arCAPACITIES
cooling
cooling capacity kW 9.7 16.2 19.8 29.0 38.9 55.0Power input kW 4.6 6.8 8.9 12.6 16.9 24.0
EEr 2.13 2.38 2.22 2.3 2.3 2.3cooling circuit 1 1 1 1 2 2
VENTILATION
available static pressure Pa 200 300 200 200 250 290nominal airflow m³/h 2000 3200 4500 5800 9000 12000
airflow range (min/max) m³/h 1500/2500 2500/3800 3600/5400 4600/7000 7200/10800 9500/14500SOUND LEVELS
Sound power level dB(A) 66 68 75 81 77 85DIMENSIONS
lxWxH mm 890x430x1540 1000x500x1735 1300x600x1840 1530x600x1840 1715x790x1970 1980x790x1970Plenum height mm 220 260 350 350 400 400
WEIGHT
unit weight kg 136 182 265 350 525 600
outdoor unit uc 33 a uc 53 a uc 73 a uc 103 a uc 73 a uc103 acondenser unit 1 1 1 1 2 2
VENTILATION
nominal airflow m³/h 220 260 350 350 400 400SOUND LEVELS
Sound power level dB(A) 54 58 61 73 64 76DIMENSIONS
lxWxH mm 885x825x831 885x825x831 1141x885x831 1546x885x893 1141x885x831 1546x885x893WEIGHT
unit weight kg 59 68 93 130 93 130
POWER SUPPLy
Power supply 400V/3P/50 HzPower supply side Indoor
PIPE LINE
Suction pipe diameter inches 1/2" 1/2" 5/8" 3/4" 5/8" 3/4"liquid pipe diameter inches 3/8" 3/8" 1/2" 5/8" 1/2" 5/8"
Max lenght m 45 45 45 45 45 45
PRODUCT CODE
indoor unit Code 7XU022082 7XU022077 7XU022078 7XU022079 7XU022080 7XU022081outdoor unit Code 7XU031025 7XU031026 7XU031027 7XU031028 2 x 7XU031027 2 x 7XU031028
ACCESSORIES
Set of female valves Code 7ACFH0054 7ACFH0055 7ACFH0056 7ACFH0061 7ACFH0057 7ACFH0060Pipe link Code 7ACFH0210 7ACFH0211 7ACFH0212 7ACFH0213 7ACFH0214 7ACFH0215
Electric heaterkW 9 12 18 22.5 37.5 45Code 7ACEl0042 7ACEl0043 7ACEl0057 7ACEl0058 7ACEl0116 7ACEl0119
Hot water coil kW 15.5 29.7 38.5 50 77 94Code 7ACFH0062 7ACFH0063 7ACFH0064 7ACFH0118 7ACFH0180 7ACFH0170
on/oFF switch and room thermostat Code 7ACEl0041 7ACEl0041 7ACEl0032 7ACEl0032 7ACEl0032 7ACEl0032"High ventilation" Code 7ACVF0023 7ACVF0024 - - - -
"all season" system Code 7ACFH0069 7ACFH0070 7ACFH0104 7ACFH0072 7ACFH0071 7ACFH0146remote fault reporting Code 7ACEl0072 7ACEl0072 7ACEl0071 7ACEl0071
air distribution duct frame Code 7ACVF0101 7ACVF0102 7ACVF0050 7ACVF0051 7ACVF0052 7ACVF0052total rear air intake duct frame Code 7ACVF0041 7ACVF0104 7ACVF0043 7ACVF0044 7ACVF0045 7ACVF0046
Front air distribution plenum Code 7ACVF0105 7ACVF0106 7ACVF0108 7ACVF0109 7ACVF0110 7ACVF0111Fresh air intake Code 7ACVF0047 7ACVF0047 - - - -
166
Commercial Air Conditioning |
167
x A0VErtical WatEr caBinEt - cooling only
cooling capacity: from 8 to 45.7 kW refrigerant: r407c Sizes: 6
CONFIGURATIONS: Monobloc system
PRODUCT ADVANTAGES Easy installation and maintenance. Monobloc system. Public or recycled water operation. treated air distribution to premise by plenum or duct network.
adjustable available static pressure. temperature control by thermostat. Electrical, refrigeration and thermal protection devices.
MAIN OPTIONS room thermostat. Electric heater. Hot water heating coil. remote fault reporting. Plenum. duct flange.
Operating limit fOr Standard unitINDOOR UNIT
Minimum air temperature 21°C DB/15°C WB
Maximum air temperature 32°C DB/23°C WB
Minimum water temperature +10°C
Maximum water temperature +30°C
166 167
x ao cx 25 x 1100 ao x 1900 ao x 2450 ao x 3250 ao x 4650 aoCAPACITIES
cooling
cooling capacity kW 8.0 11.7 18.0 23.0 32.4 45.7Power input kW 2.6 3.8 5.8 7.1 9.8 13.9
EEr 3.14 3.08 3.1 3.24 3.31 3.29cooling circuit 1 1 1 1 1 2
VENTILATION
available static pressure Pa 80 200 250 200 250 250nominal airflow m³/h 1500 2000 3200 4500 5800 9000
airflow range (min/max) m³/h 1160/1750 1500/2500 2500/3800 3600/5400 4600/7000 7200/10800HyDRAULIC
Wasted water
Water flow m³/h 0.34 0.58 0.92 1.45 2 2.8pressure drop kPa 20 22 18 42 40 18
recycled water
Water flow m³/h 1.17 2.1 3.4 4.3 5.8 8.3pressure drop kPa 21 50 70 60 40 56
SOUND LEVELS
Sound power level dB(A) 64 65 67 74 80 76POWER SUPPLy
Power supply 230/1P/50 Hz 400V/3P/50 Hz 400V/3P/50 Hz
DIMENSIONS
lxWxH mm 800x407x 1280 890x430x1540 1000x500x1735 1300x600x1840 1530x600x1840 1715x790x1970Plenum height mm 300 220 260 350 350 400
WEIGHT
unit weight kg 125 151 199 305 380 565
PRODUCT CODE
230V/1P/50 Hz Code 7XU012032 - - - - -
400V/3P/50 Hzwith valve Code 7XU012033 7XU012025 7XU012028 7XU012029 7XU012030 7XU012031
without valve Code - - - 7XU012047 7XU012048 7XU012064
ACCESSORIES
Electric heater
kW 5.49 9 12 18 22.5 37.5230V/1P/50 hz code 7ACEl0017 - - - - -400V/3P/50 Hz Code 7ACEl0018 7ACEl0042 7ACEl0043 7ACEl0057 7ACEl0058 7ACEl0116
Hot water coil kW - 15,5 29,7 38,5 50 77Code - 7ACFH0062 7ACFH0063 7ACFH0064 7ACFH0118 7ACFH0180
on/oFF switch and room thermostat Code 7ACEl0030 7ACEl0041 7ACEl0041 7ACEl0032 7ACEl0032 7ACEl0032"High ventilation" Code 7ACVF0025 7ACVF0023 7ACVF0024 - - -
Sum heating resistance Code 7ACVF0027 7ACVF0029 included - - -remote fault reporting Code 7ACEl0072 7ACEl0072 7ACEl0071
air distribution duct frame Code - 7ACVF0101 7ACVF0102 7ACVF0050 7ACVF0051 7ACVF0052total rear air intake duct frame Code - 7ACVF0041 7ACVF0104 - - -
Front air distribution plenum Code 7ACVF0112 7ACVF0105 7ACVF0106 7ACVF0108 7ACVF0109 7ACVF0110Fresh air intake Code - 7ACVF0047 7ACVF0047 - - -
168
Commercial Air Conditioning |
169
CDNair coolEd condEnSing unit - cooling ModE
cooling capacity: from 19 to 83 kW refrigerant: r407c Size: 8 configurations: Monobloc system
PRODUCT ADVANTAGES Weather resistant casing with external panels coated with powder-based epoxy paint colour ral 9001. compatible with any indoor unit. Easy service acces to main components. Hermetic Scroll compressor with crankcase heater. low noise fan. Phase controller. External HP and lP pressure taps. Electrical, refrigeration and thermal protection devices.
MAIN OPTIONS BaZ version: complete with standard component and fan speed controller. Bac version: BaZ version + suction accumulator. Bal version: BaZ version + suction accumulator + liquid receiver.
Operating limit fOr Standard unitCOOLING MODE
Minimum outdoor air temperature (with fan speed controller) -10°C
Maximum outdoor air temperature 46°C DB
168 169
cdn unit cdn 205
cdn 305
cdn 405 m
cdn 405
cdn 505
cdn 605
cdn 755
cdn 905
CAPACITIES
cooling capacity kW 18,6 27,8 36,0 35,1 44,4 55,6 69,1 83,0Power input kW 6,5 9,5 12,4 13,0 16,1 19,0 22,9 27,5
number of refrigerant circuits 1 1 1 2 2 2 2 2VENTILATION
number of fan 1 1 1 2 2 2 2 2nominal airflow m³/h 8600 9000 16000 2x9000 2x9000 2x9000 2x16000 2x16000
SOUND LEVELS
Sound power level dB(A) 78 82 83 82 84 87 87 87POWER SUPPLy
Power supply 400V/3P + N + Earth/50 HzMax current A 16,5 24 32 38 39 47 56 67
Max starting current A 104 131 121 123 113 153 192 234REFRIGERANT CONNECTION
Suction pipe diameter inches 1-1/8" 1-1/8" 1-3/8" 1-1/8" 1-1/8" 1-1/8" 1-3/8" 1-3/8"liquid pipe diameter inches 1/2" 1/2" 5/8" 1/2" 1/2" 1/2" 5/8" 5/8"
DIMENSIONS (LxWxH)
mm 900x800x1060 1003xx1003x1094 1003xx1003x1250 1708x1123x972 1708x1123x1171 1708x1123x1171 2213x1345x1304 2213x1345x1454 WEIGHT
unit weight kg 164 187 245 317 378 405 490 530
PRODUCT CODES
Bac Code 7SP112103 7SP112107 - 7SP112144 7SP112111 7SP112115 - -Bal Code 7SP112220 7SP112208 7SP112198 7SP112230 7SP112216 7SP112217 7SP112218 7SP112219BaZ Code 7SP112102 7SP112106 7SP112133 7SP112182 7SP112110 7SP112114 7SP112139 7SP112148
170
Commercial Air Conditioning |
171
AQC 40 75air-coolEd condEnSing cHillEr
cooling capacity: from 41 to 80 kW refrigerant: r410a Sizes: 10
MAIN FeATUReS 2 scroll compressors/1 refrigerant circuit
VeRSIONS: Std: Standard SiF: ducted installation (40-75 sizes only)
ACOUSTIC OPTIONS: Bln Basic low noise Eln Extra low noise (40-75 sizes only)
PRODUCT ADVANTAGES r410a refrigerant. Simpler refrigerant circuit layout. low sound level for Bln unit, very low sound level for Eln unit (only 40-75 sizes). great accessibility to internal components for service operations. new display on external panel allowing the complete control of the unit. Wide operating limits. High temperature operation up to 50°c.
Standard configuration: Phase sequence monitor supplied as standard. rubber pads supplied as standard.
MAIN OPTIONS coil with blue fins,with “Fin guard Silver” or black epoxy treatment. Soft starter. Power supply without neutral kit, (only 40-75 sizes). automatic circuit breaker (only 40-75 sizes). compressor overload protection, (only 40-75 sizes).
MAIN ACCESSORIES antivibration kit (only 40-75 sizes). remote on/off control. Fan speed control kit. gauge kit. ModBus protocol kit for BMS. Power factor correction capacitors. Sequencer for up to 4 chillers installation. compressor soundproof jackets (this option is standard on Eln version (only 40-75 sizes).
Operating limit fOr Standard unitCOOLING MODE Sizes
evaporating temperature -12°C
Outdoor air temperature BLN -18/46°C 40-75
Outdoor air temperature eLN -18/43°C 40-75
Outdoor air temperature SIF-20/50°C 40-50
-20/48°C 60-75
NOTESOperating limits are referred to full load
R410A
170 171
aQc siZes 40 45 50 60 65 75 bLN COOLING CAPACITy KW 43.2 48.8 56.9 67.4 73.8 84.5
input Power (compressor) kW 13.0 15.3 17.8 18.7 21.6 26.3ELN COOLING CAPACITy KW 41.6 46.7 54.0 64.9 70.7 80.6
input Power (compressor) kW 13.7 16.3 19.1 19.7 22.8 28.1SIF COOLING CAPACITy KW 45.8 52.1 61.3 68.4 75.2 85.9
input Power (compressor) kW 11.9 13.9 16.0 18.3 21.1 25.6number of refrigerant circuits 1 1 1 1 1 1
Part load step % 0-50-100 0-50-100 0-50-100 0-44-56-100 0-50-100 0-50-100Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz
Startup type Direct Direct Direct Direct Direct DirectMaximum current (Fla) A
Refert to electrical dataStartup current (lra) A
REFRIGERANT type R410A
COMPRESSOR number 2 2 2 2 2 2
type Scroll Scroll Scroll Scroll Scroll Scroll crankcase heater W 90 90 90 90 90 90
COIL number 1 1 1 1 1 1
Frontal surface l x a 2160x1200 2160x1200 2160x1200 2650x1200 2650x1200 2650x1200rows 2 2 3 3 3 3
FANS number 1 1 1 1 1 1
airflow rate Bln m³/h 14000 14000 13200 21100 21100 21100Speed Bln rpm 680 680 680 900 900 900
input power Bln kW 0.98 0.98 0.98 2.00 2.00 2.00airflow rate Eln m³/h 11000 11000 10300 16000 16000 16000
Speed Eln rpm 530 530 530 720 720 720input power Eln kW 0.57 0.57 0.57 1.27 1.27 1.27
airflow rate SiF m³/h 25284 25284 24300 25284 25284 25284Speed SiF rpm 1110 1110 1110 1110 1110 1110
input power SiF kW 0.57 2.67 2.67 2.67 2.67 2.67REFRIGERANT CONNECTIONS
type To be brazed inlet diameter inches 5/8” 5/8” 5/8” 7/8” 7/8” 7/8”
outlet diameter inches 1” 3/8 1” 3/8 1” 3/8 1” 3/8 1” 3/8 1” 3/8 WEIGHT
Shipping weight kg 391 399 422 456 466 469operating weight kg 391 399 422 456 466 469
DIMENSIONS length mm 1750 1750 1750 2200 2200 2200 Width mm 1100 1100 1100 1100 1100 1100
Height mm 1580 1580 1580 1580 1580 1580 ACOUSTICAL DATA (NORMAL MODE)
Sound Power level Bln dB(A) 80.5 81.0 81.0 85.5 85.6 85.8 Sound Pressure level Bln (1) dB(A) 48.9 49.4 49.4 53.8 53.9 54.1
Sound Power level Eln dB(A) 74.0 75.3 75.3 78.0 78.5 79.0 Sound Pressure level Eln (1) dB(A) 42.4 43.7 43.7 46.3 46.8 47.3
(1) Sound pressure calculated at 10 m.
172
Commercial Air Conditioning |
173
AQVC 85-140air-coolEd condEnSing cHillEr
cooling capacity: from 84 to 137 kW refrigerant: r410a Sizes: 6
VeRSIONS: Std: Standard HSE: High Seasonal Efficiency Ht: High temperature HPF: High Pressure Fan.
ACOUSTIC OPTIONS: Bln Basic low noise ln low noise
PRODUCT ADVANTAGES 4 scroll compressors. 2 independant refrigerant circuits. V-shape condenser coils ensuring compactness and small foot print. Standard Microchannel coils. inverter fans for HSE version.
MAIN OPTIONS HP & lP manometers. compressor soft starter. Power factor correction capacitors. compressor overload protection. automatic circuit breaker. HP & lP manometers. coil guards. chiller grilles. condenser coils treatments. different protocol kit for BMS.
MAIN ACCESSORIES chiller grilles. Master and slaves control, up to 4 units max. remote keyboard panel.
Operating limit fOr Standard unit85
Min. Max.evaporating temperature +1 to +15 °C
Ambient air
Air entering temperature
BLN 0 to +48°C
eLN -18 to +45°C
HT 0 to +50 °C
external static pressure
Standart fans 0
High pressure fans ≤ 120
Power supply voltage 400V/3Ph/50Hz (nominal)
R410A
172 173
aQvc size 85 95 105 115 125 140 bLN COOLING CAPACITy * KW 92.1 103.2 113.2 121.8 134.7 151.0
input power (compressor) kW 25.3 29.3 32.0 34.9 38.3 43.4ELN COOLING CAPACITy * KW 89.0 99.4 108.7 116.6 131.6 147.2
input power (compressor) kW 26.8 31.3 34.3 37.5 39.8 45.2HT COOLING CAPACITy * KW 95.0 106.8 117.7 127.0 137.2 153.8
input power (compressor) kW 23.9 27.4 29.8 32.3 37.1 42.1number of refrigerant circuits 2 2 2 2 2 2
Part load steps 0-25-50-75-100 0-25-50-75-100 0-24-47-74-100 0-25-50-75-100 0-22-43-72-100 0-25-50-75-100Power supply 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz 400V/3/50Hz
Startup type Direct Direct Direct Direct Direct Direct COMPRESSOR
number 4 4 4 4 4 4 type Scroll Scroll Scroll Scroll Scroll Scroll
crankcase heater W 90 90 90 90 90 90COIL
number 2 2 2 2 2 2 Frontal surface 2000x1200 2000x1200 2000x1200 2000x1200 2600x1200 2600x1200
FANS
number 2 2 2 2 2 2
Blnairflow rate m³/h 34000 34000 33200 32400 44000 42800
Speed rpm 690 690 3690 690 900 900input power kW 2.1 2.1 2.1 2.1 3.4 3.4
Elnairflow rate m³/h 25200 25200 24600 24000 36500 35000
Speed rpm 500 500 500 500 690 690input power kW 1.8 1.8 1.8 1.8 2.1 2.1
Htairflow rate m³/h 49700 49700 48950 48200 52200 50700
Speed rpm 1130 1130 1130 1130 1130 1130input power kW 4.6 4.6 4.6 4.6 4.6 4.6
REFRIGERANT CONNECTIONS
type Brazed connectionsinlet diameter inches 5/8” 5/8” 5/8” 5/8” 5/8” 5/8”
outlet diameter inches 1” 3/8 1” 3/8 1” 3/8 1” 3/8 1” 3/8 1” 3/8WEIGHT
Bln-Ht Shipping weight kg 971 983 1013 1043 1066 1142Eln Shipping weight kg 1001 1013 1043 1073 1096 1172DIMENSIONS
length mm 2555 2555 2555 2555 3155 3155 Width (transport only) mm 1095 (1250) 1095 (1250) 1095 (1250) 1095 (1250) 1095 (1250) 1095 (1250)
Height mm 2185 2185 2185 2185 2185 2185 ACOUSTIC DATA
BlnSound power level dB(A) 85 85 85 85 89 89
Sound pressure level (1) dB(A) 53 53 53 53 57 57
ElnSound power level dB(A) 82 82 82 82 86 86
Sound pressure level (1) dB(A) 50 50 50 50 54 54
HtSound power level dB(A) 95 95 95 95 95 95
Sound pressure level (1) dB(A) 63 63 63 63 63 63
(1) Sound pressure calculated at 10 m. Sound pressure levels refer to ISO standard 3744 with parallepiped shape.(*) Data based on: 7°C evaporating temperature and 35°C condenser inlet air temperature.
174
Commercial Air Conditioning |
175
VLC 524-1204air-coolEd condEnSing cHillEr cooling capacity: from 137 to 308 kW refrigerant: r410a Sizes: 8
MAIN FeATUReS: 4 scroll compressors/2 independent refrigerant circuits
VeRSIONS: Std: Standard HSE: High Seasonal Efficiency Ht: High temperature HPF: High Pressure Fans
ACOUSTIC OPTIONS (FOR STD AND HSe VeRSIONS): Bln Basic low noise ln low noise Eln Extra low noise
PRODUCT ADVANTAGES 2 independant refrigerant circuits. 4 scroll compressors. r410a refrigerant. large choice of configurations: 4 versions and 3 acoustic option with largec choice of accessories. Ec fans for Hight Seasonal Efficiency version, High temperature and High Pressure Fans.
MAIN OPTIONS ModBus, lonwork, Bacner protocol kit for BMS. compressors soft starter. Pressure actuated stepless fan speed controller for low ambient operation (-18°c). Power factor correction capacitors. compressors overload protection. gSM. HP & lP manometers. condenser coils with blue fins treatment, “Fin guard Silver” (polyurethane) treatment or copper fins. chiller grilles.
MAIN ACCESSORIES remote on/oFF control. remote keyboard panel. Master and slaves control, up to 4 units max. Spring anti-vibration.
Operating limit fOr Standard unit524 904
Min. Max. Min. Max.evaporating temperature +3 to +15 °C +3 to +15 °C
Ambient air
Air entering temperature
Cooling BLN 0 to +46°C 0 to +47°C
Cooling LN/eLN 0 to +44°C 0 to +45°C
Cooling HT -18 to +48°C -18 to +49°C
external static pressure
Standart fans 0 0
High pressure fans ≤ 120 ≤ 120
Power supply voltage (2) 400V/3Ph/50Hz (nominal) 400V/3Ph/50Hz (nominal)
(1) High pressure switch at 40.5 bar.(2) Voltage: 400V±10%.
R410A
174 175
vlc 524 604 704 804 904 1004 1104 1204STD/HSE/SIF bLN COOLING CAPACITy (1) KW 154.0 174.0 199.0 224.0 258.0 283.0 315.0 347.0
input power (compressor) (2) kW 47.5 52.5 63.0 69.0 79.0 83.0 98.0 112.0STD/HSE LN COOLING CAPACITy (1) KW 149.0 169.0 194.0 218.0 251.0 272.5 301.0 330.0
input power (compressor) (2) kW 50.0 55.0 66.0 73.0 83.0 88.0 104.0 121.0STD/HSE ELN COOLING CAPACITy (1) KW 144.0 164.5 188.5 211.0 244.0 264.5 292.0 319.0
input power (compressor) (2) kW 52.5 57.0 69.0 76.5 86.5 91.5 108.0 127.0total EEr* 2.47 2.55 2.46 2.48 2.53 2.59 2.43 2.28
number of refrigerants circuits 2 2 2 2 2 2 2 2total capacity steps 25-50-75-100 25-57-78-100 20-50-70-100 25-50-75-100 28-50-78-100 25-50-75-100 23-50-73-100 25-50-75-100
COMPRESSORS
number 4 4 4 4 4 4 4 4 type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll
oil type POE POE POE POE POE POE POE POEnumber of loading stages 0/100 0/100 0/100 0/100 0/100 0/100 0/100 0/100
AIR COOLED CONDENSERS
number 2 2 2 2 2 2 2 2total coil face area per coil m2 3.5 3.5 4.8 4.8 4.8 4.8 4.8 4.8
FANS
number 2 3 3 3 4 4 4 4
Bln
nominal speed rpm 900 900 900 900 900 900 900 900total airflow m³/h 46300 63000 68300 68300 85000 80000 75500 75500
total input power kW 3.8 5.7 5.7 5.7 7.6 7.6 7.6 7.6total input power (3) kW 2.6 4.0 4.0 4.0 5.3 5.3 5.3 5.3
External static pressure Pa 0 or 120 Pa (4)
ln
nominal speed rpm 700 700 700 700 700 700 700 700total airflow m³/h 35400 47300 52200 52200 63700 58800 54900 54900
total input power kW 2.4 3.6 3.6 3.6 4.8 4.8 4.8 4.8total input power (3) kW 1.2 1.9 1.9 1.9 2.5 2.5 2.5 2.5
External static pressure Pa 0
Eln
nominal speed rpm 550 550 550 550 550 550 550 550total airflow m³/h 28300 38500 41800 41800 52000 48900 46200 46200
total input power kW 2 3 3 3 4 4 4 4total input power (3) kW 0.6 0.9 0.9 0.9 1.2 1.2 1.2 1.2
External static pressure Pa 0REFRIGERANT CONNECTION
inlet diameter inches 7/8” 7/8” 7/8” 7/8” 1 1/8” 1 1/8” 1 1/8” 1 1/8”outlet diameter inches 1 5/8” 1 5/8” 1 5/8” 1 5/8” 2 1/8” 2 1/8” 2 1/8” 2 1/8”
WEIGHT
Bln-ln Shipping weight kg 1080 1300 1490 1615 1700 1825 1910 1920Eln Shipping weight kg 1110 1335 1525 1650 1735 1865 1950 1960ADDITIONAL WEIGHT
HSE version kg 30 30 30 30 40 40 40 40SiF version kg 10 10 10 10 15 15 15 15
DIMENSIONS
length mm 3300 3300 4300 4300 4300 4300 4300 4300 Width mm 1100 1100 1100 1100 1100 1100 1100 1100
Height mm 2300 2300 2300 2300 2300 2300 2300 2300 ACOUSTIC DATA
BlnSound power level (5) dB(A) 92 93 93 93 94 94 95 95
Sound pressure level (6) dB(A) 60 61 61 61 62 62 63 63
lnSound power level (5) dB(A) 86 87 87 87 88 88 89 89
Sound pressure level (6) dB(A) 54 55 55 55 56 56 57 57
ElnSound power level (5) dB(A) 83 83 83 83 84 84 85 85
Sound pressure level (6) dB(A) 51 51 51 51 52 52 53 53
(1) Data based on 7°C evaporating temperature and 35°C ambient air temperature.(2) Compressors only.(3) High efficiency units (HSe) with inverter fans.(4) SIF units with high static pressure fans. (5) Sound levels are at fully loaded conditions. Sound power level values refer to ISO standard 3744 and eurovent 8/1.(6) Sound pressure levels refer to ISO standard 3744, parallelepiped shape.
176 177
notes
176 177
178 179
notes
178 179
Airwell France SAS1 bis avenue du 8 mai 194578280 GuyancourtFranceTel. +33 (0)1 39 44 78 00Fax +33 (0)1 39 44 00 14www.airwell.com
CA
C A
GB
051
2 -
Sp
ecifi
catio
ns s
ubje
ct t
o ch
ange
with
out
notic
e. P
ictu
res
non
cont
ract
ual.
Prin
ted
in U
E.