    1 | © 2011 DrinkStar GmbH | 14.03.2012

    INSTALLATION OF DOSING-UNIT

    Beverage pipeline from the dosing-unit to the filler: 2-10 m length

    (at least 2 bows at 90 , supported, strainless)

    Inlet run before IDM: ≥≥≥≥ 5 times pipeline diameter 

  • 8/18/2019 2012-03-14 Recommedation of Installation of VDT (002)

    2/6

    2 | © 2011 DrinkStar GmbH | 14.03.2012

    Beverage pipeline from the dosing-unit to the filler: 2-10 m length

    at least 2 bows at 90 before filler 

    fixed Pipes (supported, strainless)

    Inlet run before IDM: ≥ 5 times pipeline diameter 

    horizontal and stable building

    easily accessible from all sides

    option for sampling (beverage) before dosing-Unit

    Compressed air (4-6 bar, oil- / water-free)

    Power supply (230 V)

    INSTALLATION OF DOSING-UNIT

  • 8/18/2019 2012-03-14 Recommedation of Installation of VDT (002)

    3/6

    3 | © 2011 DrinkStar GmbH | 14.03.2012

    Please note the installation/dismounting of the

    Velcorin Dosing Unit should be effected in

    agreement with our application engineer.

    INSTALLATION OF DOSING-UNIT

  • 8/18/2019 2012-03-14 Recommedation of Installation of VDT (002)

    4/6

    4 | © 2011 DrinkStar GmbH | 14.03.2012

    INVOLVMENT OF DOSING-UNIT

    IN THE FILLING PROCESS 1

    Filler Mixer Dosing-Unit

  • 8/18/2019 2012-03-14 Recommedation of Installation of VDT (002)

    5/6

    5 | © 2011 DrinkStar GmbH | 14.03.2012

    INVOLVMENT OF DOSING-UNIT

    IN THE FILLING PROCESS 2Filler Mixer Dosing-Unit

  • 8/18/2019 2012-03-14 Recommedation of Installation of VDT (002)

    6/6

    6 | © 2011 DrinkStar GmbH | 14.03.2012

    INVOLVMENT OF DOSING-UNITIN THE FILLING PROCESS 3

    Filler Mixer  Dosing-UnitFlash-pasteuriser