MAXILUMEA R C H I T E C T U R A L L I G H T I N G
W W W . M A X I L U M E . C O M
INCLV
CFLLED
HID CMH
Lighting has evolvedLife without light is inconceivable.It has evolved to become not just a necessity, but a form of art. Just like a painting, Proper lighting has the power to shape our moods, feelings and experiences. It has the power to create a dark lifeless room into a glowing masterpiece.
MAXILUME has mastered the art of lighting through experience and
dedication, and as a result, it has become a premier source of lighting
products for the home, office and business worldwide. Lighting products
supplied by MAXILUME have led to dramatic improvements in these spaces,
creating the desired mood, aura and appearance. MAXILUMEs state-of-
the-art light sources have earned the trust and confidence of customers
through their aesthetics effect, reliability and endurance. MAXILUME can
satisfy the most demanding expectations in beauty, style and ambiance
to produce the ideally integrated and defined decor. Whether providing
comfortable task lighting for a corporate boardroom or kitchen, or creating
a wash of light on an elegant painting in a stately home or office, no other
lighting product can create a high-quality visual environment like MAXILUME
products. MAXILUME has evolved from incandescent to fluorescent to
the all new LED light source. All these products are unique in design,
engineering, performance and finish, making them be recognized as the
latest innovation in the lighting world. One look at MAXILUME products
and youll discover a wealth of powerful features and creative designs to
provide the utmost in performance and versatility that easily surpasses the
competition.
2 www.maxilume.com tel 1-877-375-5555 fax 1-877-375-3333
3submittal form is available online @ http://www.maxilume.com
OUR COMPANYMAXILUME is a family owned Lighting manufacturer company based in Los Angeles, California. We have over 250,000 square feet of distribution space nationwide and an in house assembly team that works diligently to assemble products that meet our same day shipping policy.
MAXILUMEs mission is to be the premier source of lighting fixtures and products
for customers in a wide variety of residential, commercial, and industrial settings.
To achieve this ambitious goal, MAXILUME constantly strives for the highest
standards of excellence in customer service. Our unwavering commitment to
service and quality has made MAXILUME one of the worlds leading suppliers of
lighting fixtures.
From its inception, MAXILUME has energetically applied its wealth of human,
aesthetic, and technical resources to satisfy the rigorous standards and demanding
expectations of professional builders and architects. The meticulous care that we
have taken to learn about the sciences of architecture and lighting, combined
with our relentless quest for perfection in product quality and performance, has
enabled MAXILUME to maintain an edge over its competitors and repeatedly earn
the privilege to serve customers in an extensive array of architectural settings.
Listening to our customers, keeping abreast with the latest developments in our
industry, and constantly implementing improvements these are some of the
ways we have continued our preeminence in the industry.
4 www.maxilume.com tel 1-877-375-5555 fax 1-877-375-3333
5submittal form is available online @ http://www.maxilume.com
Creating the perfect fixture masterpiece not only consists of using the right electrical components, but also the perfect reflector design. Maxilume
reflectors have been engineered to deliver optimum performance, regardless of the type of light source being used. Its precise optical
control ensures a reliable solution to every architectural lighting project.
The Art Behind The Masterpiece Maxilume reflectors use the highest grade reflector alloy and are spun to a thickness of .05 to ensure strength and longevity.
Self Flanged trims provide additional durability and ease of installation on the job.
Patented design ensures high efficiencies in the mid to high 60s and with a 45-55 degree cutoff, glare is reduced to maximize comfort
of light.
Exceptional and consistent trim finished eliminate rainbow effect and guarantee to keep the integrity of the design pure
in any application.
Standardized reflector design keeps consistency between lamp types, making any space look balanced and pure.
Wide variety of color options and lenses give Maxilume reflectors that extra edge in product availability and
quick delivery times.
thE ARt Of LIghtINg
REfLECtORS
CH-CHroMe
WT-WHeAT
MB-BlACk
SHZ-SATin HAZe
WH-WHiTe
8 www.maxilume.com tel 1-877-375-5555 fax 1-877-375-3333
leD DoWnligHTHV6-LED .................................... 126 LED Optics ............................. 14HV8-LED .................................... 168 LED Optics ............................. 18HH4SQ-LED ................................ 204 LED Square Optics ................. 21H3-LED ...................................... 22H3-LED-IC .................................. 23H3-LED-R ................................... 243 LED Optics ............................. 25H4-LED ...................................... 28H4-LED-IC .................................. 29H4-LED-R ................................... 304 LED Optics ............................. 31H5-IC-LED .................................. 345 LED Optics ............................. 35H6-IC-LED .................................. 406 LED Optics ............................. 41EX4-LED..................................... 52EX6-LED..................................... 54EX4SQ-LED ................................ 56HH6-LED .................................... 58
MeTAl HAliDe (MH)H3MH-MR16 ............................ 168HR3MH-MR16 .......................... 169H3MH-MR16-IC ........................ 170H4MH-MR16-IC ........................ 174H4MH-MR16 ............................ 175HR4MH-MR16 .......................... 176H4MH-T4 ................................. 182H4MH-T6 ................................. 183H4MH ...................................... 184C4MH ...................................... 186HR4MH .................................... 188HJ4MH ..................................... 189H6MH ...................................... 190C6MH ...................................... 192HR6MH .................................... 194HJ6MH ..................................... 195H8MH ...................................... 198C8MH ...................................... 200HR8MH .................................... 202HJ8MH ..................................... 203
H10MH .................................... 206
HigH PreSSUre SoDiUM H6HPS ..................................... 210H8HPS ..................................... 212H10HPS ................................... 214
loW VolTAgeH3LV ........................................ 216H3LVIC-AT ............................... 216H4LV ........................................ 220H4LVIC-AT ............................... 220H5LV ........................................ 226H5LVIC-AT ............................... 226H6LV ........................................ 228H6LVIC-AT ............................... 228
inCAnDeSCenTH4InC ...................................... 230C4InC ...................................... 232HR4InC .................................... 234HJ4InC..................................... 235H6InC ...................................... 236C6InC ...................................... 238BHVR6InC ................................ 240HR6InC .................................... 242HJ6InC..................................... 243H8InC ...................................... 244C8InC ...................................... 246BHVR8InC ................................ 248HR8InC .................................... 250HJ8InC..................................... 251H10InC .................................... 252
FlUoreSCenTLite Optics .................................. 62new Lite Optics .......................... 64Lutron Hi-Lume .......................... 66HH4SQPL ................................... 68HH4SQPLIC ................................ 70HH4X9SQPL ............................... 72HH9X9SQPL ............................... 74BH8SQPL-IC ............................... 76BH8SQPL ................................... 77HV4PL ........................................ 78CV4PL ........................................ 80HV4PLIC-AT ............................... 82HVR4PL ...................................... 84HVJ4PL ...................................... 85CV5PL ........................................ 86HV6PL ........................................ 886 Ver. Polycar. Optics ................ 91CV6PL ........................................ 92BHVR6PL.................................... 94HVR6PL ...................................... 96HVJ6PL ...................................... 97CV7PL ...................................... 100
HV8PL ...................................... 102CV8PL ...................................... 104BHVR8PL.................................. 106HVR8PL .................................... 108HVJ8PL .................................... 109HV10PL .................................... 112HS6PL ...................................... 114HH6PL ..................................... 1166 Hor. Polycar. Optics .............. 119CH6PL ..................................... 120HH6PLIC-AT ............................. 1226 Hor. Polycar. Optics .............. 125BHHR6PL ................................. 126HHR6PL ................................... 128HHJ6PL .................................... 129CH7PL ..................................... 132HHJ7PL .................................... 134HS8PL ...................................... 136HH8PL ..................................... 138CH8PL ..................................... 140HH8PLIC................................... 142BHHR8PL ................................. 144HHR8PL ................................... 146HHJ8PL .................................... 147HH10PL ................................... 150HW6PL ..................................... 152HW8PL ..................................... 153Info for Electronic CFL ............... 154Advance Mark 7 ....................... 156Advance Mark 10 ..................... 156Lutron Hi-Lume ........................ 162Emg. Battery Pack .................... 164Emg. Ballasts ........................... 165
table of contents
9submittal form is available online @ http://www.maxilume.com
CYlinDerSCV6PL-CM ............................. 256SCV6PL-WM ............................ 256SCV6PL-PM ............................. 256SCV8PL-CM ............................. 260SCV8PL-WM ............................ 260SCV8PL-PM ............................. 260SC6MH-CM .............................. 264SC6MH-WM ............................. 264SC6MH-PM .............................. 264SC8MH-CM .............................. 268SC8MH-WM ............................. 268SC8MH-PM .............................. 268SC6InC-CM .............................. 272SC6InC-WM ............................. 272SC6InC-PM .............................. 272SC8InC-CM .............................. 274SC8InC-WM ............................. 274SC8InC-PM .............................. 274
eliTe leD linkEuM-LED SERIES ...................... 333EUM-LED MOUnTIng ................ 334EuM-LED ACCESSORIES ........... 335EuM-LED DRIVERS ................... 335
leD liniA CoVeSL2-LED................................... 337SL2-LED ACCESSORIES ............ 338TRAnSFORMERS ...................... 338REPLACEMEnT LAMPS ............. 339
leD STeP ligHTST8-SERIES .............................. 341ST7-SERIES .............................. 341ST4-SERIES .............................. 342ST3-SERIES .............................. 342SE-SERIES ................................ 343
SloPeD Ceiling ADAPTerMSCA-6 ................................... 254MSCA-8 ................................... 254
eMergenCY ligHTELM-803/ELM-815 ................... 306ELM-816/ELM-817 ................... 306ELM-806 .................................. 307ELM-809 .................................. 308ELM-811 .................................. 309ELM-LED-812 .......................... 310ELM-814 .................................. 311ELM-850 .................................. 312ELM-851 .................................. 313ELM-805 .................................. 314ELM-807 .................................. 315ELM-600 .................................. 316ELM-621 .................................. 317ELM-622 .................................. 318ELM-LED-624 .......................... 319ELM-810 .................................. 320ELM-820 .................................. 321nY APProVeDELX-715 ................................... 322ELX-714 ................................... 323ELM-813 .................................. 324ELX-641/ELX-642..................... 325ELX-634/635/636 .................... 326ELX-637/638/639 .................... 327SAliDAELX-616 ................................... 328ELX-716 ................................... 329ACCeSSorieSREMOTE LAMPS ....................... 330WIRE GuARDS .......................... 331VAnDAL SHIELD GuARDS ......... 331
eXiT SignELX-500 ................................... 282ELX-504 ................................... 283ELX-503 ................................... 284ELX-603 ................................... 285ELX-628 ................................... 285ELX-629 ................................... 285ELX-604/ELX-607..................... 286ELX-606/ELX-618..................... 287ELX-602/ELX-608..................... 288ELX-609/ELX-613..................... 289ELX-612 ................................... 290ELX-611 ................................... 290
ELX-614 ................................... 290ELX-623 ................................... 291ELX-632 ................................... 291ELX-633 ................................... 291ELX-505 ................................... 292ELX-617/ELX-605..................... 293ELX-707 ................................... 294ELX-615 ................................... 295ELX-610 ................................... 296ELX-709 ................................... 297ELX-704 ................................... 298ELX-LED-708 ........................... 299ELX-703 ................................... 300ELX-713 ................................... 300ELX-717 ................................... 300ELX-705 ................................... 301ELX-718 ................................... 302ELX-706 ................................... 303ELX-720 ................................... 304ELX-719 ................................... 305
MaXILUMe
10 www.maxilume.com tel 1-877-375-5555 fax 1-877-375-3333
cooLED technology allows the life of the LED Engine to reach its published life of 50,000 hrs, therefore giving you a peace of mind.
LED INNOvAtION at its best
11submittal form is available online @ http://www.maxilume.com
The all new HV-LED series architectural downlight features the most versatile LED components found in the Lighting industry today. It features a proprietary plug and play module that can be interchanged to different beam distributions ( narrow, Medium, and Wide) and color temperatures (3000K, 3500K and 4100K). Our exclusive module is designed to fit into existing architectural housings, making it a reliable solution for retrofitting projects. CooleD Thermal Management System Through extensive research and development, HV-LED architectural downlights have cooLED technology that allows the smooth flow of air to circulate through the fins of the module, causing the heat to be transferred to the surrounding environment and away from the LED engine. cooLED technology allows the life of the LED Engine to reach its published life of 50,000 hrs, therefore giving you a peace of mind. optics and PerformanceHV-LED proprietary optilux technology consists of a dual reflector design that combines unmatched performance with visual comfort. Since the LED Light source is regressed to the highest point of the trim, visual cut-off is eliminated and glare is dramatically reduced. The operating system consumes a minimal 21 watts and puts our more than 970 usable lumens with our 3000K CCT LED engine and 1150 usable lumens using our 4100K CCT LED engine. The HV-LED features a simple Dim driver that has capabilities of dimming down to 15% with a 0-10 volt dimmer.
1. oPTiCS - MAXILUME LED Optilux technology combines unmatched performance with visual comfort. Spun 0.05 thick reflector has been designed to gather the light scattered by the LED chip and shape it into functional beams that minimize brightness and glare, while eliminating lamp image. Proprietary dual level upper and lower reflector design allows for two different light distributions (Flood Spot), design capabilities are endless and unrestricted. Elite engineered superior quality, light engine; consuming less 21 watts and producing 1121 lumens.
2. PerForMAnCe - Operating system consumes only 21 watts of power and puts out 1150 usable lumens with a 41000K color temperature while our 3000K LED chip produces more than 970 lumens. All MAXILUME LED luminaries are rated at 85+ CRI and 3,000 degrees Kelvin. Our stringent chip specifications require only those Chips that produce no ultra violet and virtually no infrared. All LED luminaries are rated and tested to LM-79 and LM-80 standards by an independent laboratory.
3. THerMAl MAnAgeMenT SYSTeM - Using a proprietary cooLED Advanced Thermodynamic Design, Die-cast aluminum housing and heat management system are engineered for extremely long life and service period. Heat sink is attached to top of housing. The LED light engine is attached to the die-cast heat sink and is easily replaceable and upgradeable. Without proper heat management, any LED luminaire will fail. Our die-cast system pulls the heat form the LED chip, allowing continued cool operation for years. Life tests have shown the MAXILUME light engine output will be maintained at 70% of initial at 50,000 hours of operation.
4. DiMMABle - The Elite LED lighting system is fully dimmable down to 5% initial light output system is dimmable with a 0-10 Volt dimmer. Daylight harvesting, programmed controls, etc. will require load compensating dimmers. 120v can also be dimmed down to 15% of initial light output using standard incandescent wall dimmer (Produces 10 % less intial lumens than Mvolt Version).
5. MoUnTing FrAMe - Die-formed all die-cast construction for maximum heat dissipation and rust protection.
6. leD DriVer/JUnCTion BoX - The LED driver is rated for 50 to 60Hz at 120V /277V input, produces less than 20%THD, and has a power factor between 90% and 100% and is thermally protected for additional safety. MAXILUMEs LED driver is installed on the junction box cover so it may be serviced from below the ceiling. UL Listed for through-branch circuit wiring, provided with four knockouts, one knockout and four Romex knockouts with true pryout slots and strain clamps. Designed for straight through conduit runs. Driver is installed on the junction box cover so it may be serviced from below the ceiling.
7. MoUnTing BrACkeT - Constructed from 16 gauge steel and is supplied with C-channel that are adjustable up to 28. Mounting bracket maybe adjusted up to 2-3/4 vertically from inside the housing.
8. lenS - Choice of either clear tempered or tempered frosted lens fastened with two torsion springs. UL listed for wet or damp location.
oUr WorD - The MAXILUME LED lighting system is warranted for 3 years. As a system, we stand behind the entire MAXILUME products from housing to bar hangers.
liSTingc-UL-us listed for Damp location.c-UL-us listed for feed Through Wiring.LM79 / LM80
12 www.maxilume.com tel 1-877-375-5555 fax 1-877-375-3333
HV6-leD 6 ArCHiTeCTUrAl leD DoWnligHTing
6 in
cH
LE
D a
rch
itectu
ral D
OW
NliG
ht
Architectural MaXILUMe
Height = 8-1/2Trim Aperture = 6-1/8Cut-out = 6-3/4Trim Outside Dia. = 7-3/8Width = 16Length = 20-33
A
B
C
D
e
F
e F
A
CBD
InPuT VOLT. InPuT FREQ. InPuT CuR. LED DRIVER CuR. InPuT POWER THD POWER FACTOR120/277 50/60Hz 208mA 1240mA 21W(+/-5%) 0.9
DeSCriPTion 6 LED dedicated Architectural new Construction Downlight with integral LED heat management casting and driver (installed on junction box). Consuming 21 watts and producing 1121 usable lumens. Lighting is smooth and comfortable while using 25% less energy than the common 32W CFL downlight. Plus the eco-friendlyMaxilume LED system features 70% lumen maintenance at 50,000 hours life, with California Title-24-2008 compliance and Energy Star Rating (pending).
FeATUreSgreater light output than a 32w CFL while consuming less than 24w of power. Maxilume LED luminaires are ideally suited for use in hospitality, health care, commercial, institutions, retail and other architectural applications.
Example: HV6-leD-21W-120V-DiM-Fl-30kTYPeHV6-LED
WATTAgeo 21W
VolTAgeo 120Vo 277Vo MVOLT (120/277)
oPTiCSo FLo SP
Coloro 3000Ko 3500Ko 4100K
o LED-6101o LED-6102o LED-6107o LED-6109o LED-6110
o LED-6111o LED-6112o LED-6113o LED-6114o LED-6115
o LED-6121o LED-6122o LED-6123o LED-6125
o CLo SCHo SHz
o WTo Wo MB
o Po W
o BLUEo REDo gREEno FROST
TriM TYPe reFleCTor BAFFle glASSeMergenCYo EMg
iTeM SeleCTor: (Please check the boxes below for the option desired)DriVero DIM Dimming
*For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
ringWH Self-Flange WhiteStandard on all trimsSCH** Self-Flange Chrome** Only available on XX01 CL
SHZ* Satin Haze* Provided w/ satin haze ring only
reFleCTorCl Clear
SHZ Satin Haze (Low Iridescent)
WT Wheat
MB Black
W White
BAFFleWH White
P Black
glASSOnly available on XX09, XX10
and XX11 series.
PEnDInG
13submittal form is available online @ http://www.maxilume.com
6 in
cH
LE
D a
rch
itectu
ral D
OW
NliG
ht
Coefficients of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance 0.20
Coefficients of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance 0.20
Coefficients of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance 0.20
RC - Ceiling Cavity Reflectance RW - Wall Reflectance
ROO
M C
AVIT
y RA
TIO
rC 80% 70% 50% 30% 10% 0%rW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0%
0 119 119 119 119 117 117 117 117 111 111 111 107 107 107 102 102 102 1001 114 111 109 107 112 109 107 105 105 104 102 102 100 99 98 97 96 942 109 104 100 97 107 103 99 96 99 96 94 96 94 92 94 92 90 883 104 98 93 90 102 97 92 89 94 90 87 92 89 86 89 87 85 834 99 92 87 83 98 91 86 83 89 85 82 87 84 81 85 82 80 785 95 87 82 78 93 86 81 78 85 80 77 83 79 76 81 78 76 746 91 83 77 73 90 82 77 73 81 76 73 79 75 72 78 74 72 707 87 79 73 69 86 78 73 69 77 72 69 76 72 68 75 71 68 678 84 75 70 66 82 74 69 66 73 69 65 72 68 65 71 68 65 649 80 72 66 63 79 71 66 62 70 66 62 69 65 62 69 65 62 6110 77 68 63 60 76 68 63 60 67 63 59 67 62 59 66 62 59 58
RC - Ceiling Cavity Reflectance RW - Wall Reflectance
ROO
M C
AVIT
y RA
TIO
rC 80% 70% 50% 30% 10% 0%rW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0%
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 1001 114 111 109 107 111 109 107 105 105 103 102 101 100 99 98 97 96 942 109 104 100 97 106 102 99 96 99 96 94 96 94 92 93 91 90 883 104 98 93 89 102 96 92 88 94 90 87 91 88 86 89 87 84 834 99 92 87 83 97 91 86 82 89 85 81 87 83 81 85 82 80 785 95 87 82 78 93 86 81 77 84 80 77 83 79 76 81 78 75 746 91 82 77 73 89 82 77 73 80 76 72 79 75 72 78 74 71 707 87 78 73 69 86 78 73 69 77 72 69 75 71 68 74 71 68 678 83 75 69 66 82 74 69 65 73 68 65 72 68 65 71 67 65 639 80 71 66 62 79 71 66 62 70 65 62 69 65 62 68 64 62 6010 77 68 63 59 76 68 63 59 67 62 59 66 62 59 66 62 59 58
RC - Ceiling Cavity Reflectance RW - Wall Reflectance
ROO
M C
AVIT
y RA
TIO
rC 80% 70% 50% 30% 10% 0%rW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0%
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 1001 114 111 109 107 111 109 107 105 105 103 102 101 100 99 98 97 96 942 109 104 100 97 106 102 99 96 99 96 94 96 94 92 93 91 90 883 104 98 93 89 102 96 92 88 94 90 87 91 88 86 89 87 84 834 99 92 87 83 97 91 86 82 89 85 81 87 83 81 85 82 80 785 95 87 82 78 93 86 81 77 84 80 77 83 79 76 81 78 75 746 91 82 77 73 89 82 77 73 80 76 72 79 75 72 78 74 71 707 87 78 73 69 86 78 73 69 77 72 69 75 71 68 74 71 68 678 83 75 69 66 82 74 69 65 73 68 65 72 68 65 71 67 65 639 80 71 66 62 79 71 66 62 70 65 62 69 65 62 68 64 62 6010 77 68 63 59 76 68 63 59 67 62 59 66 62 59 66 62 59 58
80
70
60
50
40
30
10020
90
424
849
1273
1697
80
70
60
50
40
30
10020
90
424
849
1273
1697
80
70
60
50
40
30
10020
90
424
849
1273
1697
MaXILUMe 6 leD PHoToMeTriCSArchitecturalHV6-leD-21W-MVolT-DiM-Fl-30k-leD-6101-SHZ TEST nO.: 26606 InPuT WATTS: 21 LuMEnS: 971 CRI: 84 EFFICACy: 41 lPW CCT: 3000k SPACInG CRITERIA: 0.8
HV6-leD-21W-MVolT-DiM-Fl-35k-leD-6101-SHZ TEST nO.: 26606 InPuT WATTS: 21 LuMEnS: 1071 CRI: 84 EFFICACy: 50 lPW CCT: 3500k SPACInG CRITERIA: 0.8
HV6-leD-21W-MVolT-DiM-Fl-41k-leD-6101-SHZ TEST nO.: 26606 InPuT WATTS: 21 LuMEnS: 1121 CRI: 84 EFFICACy: 52 lPW CCT: 4100k SPACInG CRITERIA: 0.8
Zonal lumens Summary
Zonal lumens Summary
Zonal lumens Summary
Zone
Zone
Zone
lumens
lumens
lumens
%lamp
%lamp
%lamp
%Fixt
%Fixt
%Fixt
0-300
0-400
0-600
0-900
0-300
0-400
0-600
0-900
0-300
0-400
0-600
0-900
828886952974
911.26974.891047.921071.81
952.681019.541120.510
85.391.398.1100.3
859197.8100
859197.8100
85.039197.8100
859197.8100
859197.8100
05152535455565758590
05152535455565758590
05152535455565758590
16791604134874678513015610
1867.141764.41482.91820.8285.5856.1032.8916.176.27.550
1952.011844.61550.31858.1389.4758.6534.3816.96.55.570
0
0
0
Candela Tabulation
Candela Tabulation
Candela Tabulation
0-1010-2020-3030-4040-5050-6060-7070-8080-90
0-1010-2020-3030-4040-5050-6060-7070-8080-90
0-1010-2020-3030-4040-5050-6060-7070-8080-90
150369.64308.7857.8539.4626.9214.646.19.9
165406339.6663.6343.4129.6216.16.81.99
172.5425.08355.166.5245.3830.9616.837.111.03
Zonal lumen Summary
Zonal lumen Summary
Zonal lumen Summary
zone
zone
zone
Lumens
Lumens
Lumens
Beam Angle: 614681012
106.0947.1526.5216.9711.79
4.77.19.411.814.2
BeAM DiA. MeASUreD AT 10% oF nADir F.C.
Distance to Plane
Initial NadirFootcandles
BeamSpread
Beam Angle: 614681012
116.751.8729.1718.6712.97
4.77.19.411.814.2
BeAM DiA. MeASUreD AT 10% oF nADir F.C.
Distance to Plane
Initial NadirFootcandles
BeamSpread
Beam Angle: 614681012
12254.2230.519.5213.56
4.77.19.411.814.2
BeAM DiA. MeASUreD AT 10% oF nADir F.C.
Distance to Plane
Initial NadirFootcandles
BeamSpread
Candle Power Distribution (Candelas)
Candle Power Distribution (Candelas)
Candle Power Distribution (Candelas)
Angle in Degrees
Angle in Degrees
Angle in Degrees
450
550
650
750
850
450
550
650
750
850
450
550
650
750
850
Average 00
Average 00
Average 00
3950285519051206314
4345314120961327346
4543328321901386358
Average 450
Average 450
Average 450
3950285519051206314
4345314120961327346
4543328321901386358
Average 900
Average 900
Average 900
3950285519051206314
4345314120961327346
4543328321901386358
luminance Data (cd/sq.m)
luminance Data (cd/sq.m)
luminance Data (cd/sq.m)
467
934
1400
1867
488
976
1464
1952
14 www.maxilume.com tel 1-877-375-5555 fax 1-877-375-3333
leD-6101 - REFLECTOR
leD-6115 - REFLECTOR W/ TEMPERED CLEAR GLASS
leD-6113 - BAFFLE W/ TEMPERED CLEAR GLASS
leD-6102 - BAFFLE W/ REFLECTOR
leD-6107 - WALL WASH REFLECTOR
leD-6114 - REFLECTOR W/ FROSTED GLASS LEnS
leD-6112 - BAFFLE W/ FROSTED GLASS LEnS
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH, SCH, SHz
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH
BAFFle FiniSH:
WH, P
ring FiniSH:
WH
BAFFle FiniSH:
WH, P
reFleCTor FiniSH:
CL
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH, SCH, SHz
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH
BAFFle FiniSH:
WH, P
ring FiniSH:
WH
MaXILUMe6 leD oPTiCS Architectural
A= 7-1/8B= 7-3/8
A= 7-1/8B= 7-3/8C= 1
A= 7-1/8B= 7-3/8C= 1
A= 7-1/8B= 7-3/8
A= 7-1/2B= 7-3/8C= 1
A= 7-1/2B= 7-3/8C= 1
A= 7-1/2B= 7-3/8C= 1
6 in
cH
LE
D a
rch
itectu
ral D
OW
NliG
ht
15submittal form is available online @ http://www.maxilume.com
leD-6125 - CEnTRAL ETCHED FLOAT GLASS
leD-6121 - STARDuST DECO RInG GLASS
leD-6123 - PRISM DECO RInG GLASS
leD-6122 - EuRO DECO RInG GLASS
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH
leD-6109 - DECO GLASS REFLECTOR
leD-6110 - DOuBLE RInG GLASS
leD-6111 - TRIPLE RInG GLASS
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH, SHz
glASS FiniSH:
BLuE, RED, GREEn, FROST
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH, SHz
glASS FiniSH:
BLuE, RED, GREEn, FROST
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH, SHz
glASS FiniSH:
BLuE, RED, GREEn, FROST
MaXILUMe 6 leD oPTiCSArchitectural
A= 7-1/8B= 7-3/8C= 1-1/4
A= 7-1/8B= 7-3/8C= 1-1/4
A= 7-1/8B= 7-3/8C= 1-1/4
A= 7-1/8B= 7-3/8C= 1-1/4
A= 7-1/8B= 7-3/8C= 1-1/4
A= 7-1/8B= 7-3/8C= 1-3/4
A= 7-1/8B= 7-3/8C= 2-1/4
6 in
cH
LE
D a
rch
itectu
ral D
OW
NliG
ht
16 www.maxilume.com tel 1-877-375-5555 fax 1-877-375-3333
HV8-leD 8 ArCHiTeCTUrAl leD DoWnligHTing
Architectural MaXILUMe
Height = 9Trim Aperture = 8Cut-out = 8-1/2Trim Outside Dia. = 9-1/8Width = 16Length = 20-33
A
B
C
D
e
F
e F
A
CBD
InPuT VOLT. InPuT FREQ. InPuT CuR. LED DRIVER CuR. InPuT POWER THD POWER FACTOR120/277 50/60Hz 208mA 1240mA 21W(+/-5%) 0.9
DeSCriPTion 8 LED dedicated Architectural new Construction Downlight with integral LED heat management casting and driver (installed on junction box). Consuming 21 watts and producing 1121 usable lumens. Lighting is smooth and comfortable while using 25% less energy than the common 32W CFL downlight. Plus the eco-friendlyMaxilume LED system features 70% lumen maintenance at 50,000 hours life, with California Title-24-2008 compliance and Energy Star Rating (pending).
FeATUreSgreater light output than a 32w CFL while consuming less than 24w of power. Maxilume LED luminaires are ideally suited for use in hospitality, health care, commercial, institutions, retail and other architectural applications.
1. oPTiCS - MAXILUME LED Optilux technology combines unmatched performance with visual comfort. Spun 0.05 thick reflector has been designed to gather the light scattered by the LED chip and shape it into functional beams that minimize brightness and glare, while eliminating lamp image. Proprietary dual level upper and lower reflector design allows for two different light distributions (Flood Spot), design capabilities are endless and unrestricted. Elite engineered superior quality, light engine; consuming less 21 watts and producing 1121 lumens.
2. PerForMAnCe - Operating system consumes only 21 watts of power and puts out 1150 usable lumens with a 41000K color temperature while our 3000K LED chip produces more than 970 lumens. All MAXILUME LED luminaries are rated at 85+ CRI and 3,000 degrees Kelvin. Our stringent chip specifications require only those Chips that produce no ultra violet and virtually no infrared. All LED luminaries are rated and tested to LM-79 and LM-80 standards by an independent laboratory.
3. THerMAl MAnAgeMenT SYSTeM - Using a proprietary cooLED Advanced Thermodynamic Design, Die-cast aluminum housing and heat management system are engineered for extremely long life and service period. Heat sink is attached to top of housing. The LED light engine is attached to the die-cast heat sink and is easily replaceable and upgradeable. Without proper heat management, any LED luminaire will fail. Our die-cast system pulls the heat form the LED chip, allowing continued cool operation for years. Life tests have shown the MAXILUME light engine output will be maintained at 70% of initial at 50,000 hours of operation.
4. DiMMABle - The Elite LED lighting system is fully dimmable down to 5% initial light output system is dimmable with a 0-10 Volt dimmer. Daylight harvesting, programmed controls, etc. will require load compensating dimmers. 120v can also be dimmed down to 15% of initial light output using standard incandescent wall dimmer (Produces 10 % less intial lumens than Mvolt Version).
5. MoUnTing FrAMe - Die-formed all die-cast construction for maximum heat dissipation and rust protection.
6. leD DriVer/JUnCTion BoX - The LED driver is rated for 50 to 60Hz at 120V /277V input, produces less than 20%THD, and has a power factor between 90% and 100% and is thermally protected for additional safety. MAXILUMEs LED driver is installed on the junction box cover so it may be serviced from below the ceiling. UL Listed for through-branch circuit wiring, provided with four knockouts, one knockout and four Romex knockouts with true pryout slots and strain clamps. Designed for straight through conduit runs. Driver is installed on the junction box cover so it may be serviced from below the ceiling.
7. MoUnTing BrACkeT - Constructed from 16 gauge steel and is supplied with C-channel that are adjustable up to 28. Mounting bracket maybe adjusted up to 2-3/4 vertically from inside the housing.
8. lenS - Choice of either clear tempered or tempered frosted lens fastened with two torsion springs. UL listed for wet or damp location.
oUr WorD - The MAXILUME LED lighting system is warranted for 3 years. As a system, we stand behind the entire MAXILUME products from housing to bar hangers.
liSTingc-UL-us listed for Damp location.c-UL-us listed for feed Through Wiring.LM79 / LM80
Example: HV8-leD-21W-120V-DiM-Fl-30kTYPeHV8-LED
WATTAgeo 21W
VolTAgeo 120Vo 277Vo MVOLT (120/277)
oPTiCSo FLo SP
Coloro 3000Ko 3500Ko 4100K
o LED-8101o LED-8102o LED-8107o LED-8109o LED-8110
o LED-8111o LED-8112o LED-8113o LED-8114o LED-8115
o LED-8121o LED-8122o LED-8123o LED-8125
o CLo SCHo SHz
o WTo Wo MB
o Po W
o BLUEo REDo gREEno FROST
TriM TYPe reFleCTor BAFFle glASSeMergenCYo EMg
iTeM SeleCTor: (Please check the boxes below for the option desired)DriVero DIM Dimming
*For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
ringWH Self-Flange WhiteStandard on all trimsSCH** Self-Flange Chrome** Only available on XX01 CL
SHZ* Satin Haze* Provided w/ satin haze ring only
reFleCTorCl Clear
SHZ Satin Haze (Low Iridescent)
WT Wheat
MB Black
W White
BAFFleWH White
P Black
glASSOnly available on XX09, XX10
and XX11 series.
PEnDInG
8 in
cH
LE
D a
rch
itectu
ral D
OW
NliG
ht
17submittal form is available online @ http://www.maxilume.com
MaXILUMe 8 leD PHoToMeTriCSArchitectural
Coefficients of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance 0.20
Coefficients of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance 0.20
Coefficients of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance 0.20
RC - Ceiling Cavity Reflectance RW - Wall Reflectance
ROO
M C
AVIT
y RA
TIO
rC 80% 70% 50% 30% 10% 0%rW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0%
0 119 119 119 119 117 117 117 117 111 111 111 107 107 107 102 102 102 1001 114 111 109 107 112 109 107 105 105 104 102 102 100 99 98 97 96 942 109 104 100 97 107 103 99 96 99 96 94 96 94 92 94 92 90 893 104 98 93 90 102 97 92 89 94 90 87 92 89 86 89 87 85 834 99 92 87 83 98 91 86 83 89 85 82 87 84 81 85 82 80 795 95 87 82 78 93 86 81 78 85 80 77 83 79 76 82 78 76 746 91 83 77 73 89 82 77 73 80 76 73 79 75 72 78 74 72 707 87 79 73 69 86 78 73 69 77 72 69 75 71 68 74 71 68 678 84 75 70 66 82 74 69 66 73 69 65 72 68 65 71 68 65 639 80 72 66 63 79 71 66 62 70 66 62 69 65 62 69 65 62 6010 77 68 63 59 76 67 62 59 67 62 59 66 62 59 65 61 59 57
RC - Ceiling Cavity Reflectance RW - Wall Reflectance
ROO
M C
AVIT
y RA
TIO
rC 80% 70% 50% 30% 10% 0%rW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0%
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 1001 114 111 109 107 111 109 107 105 105 103 102 101 100 99 98 97 96 942 109 104 101 97 107 103 99 96 99 97 94 96 94 92 94 92 90 893 104 98 93 90 102 97 92 89 94 91 88 92 89 86 89 87 85 834 99 92 87 83 98 91 87 83 89 85 82 87 84 81 85 83 80 795 95 87 82 78 93 86 81 78 85 80 77 83 79 76 82 78 76 746 91 83 77 73 89 82 77 73 80 76 73 79 75 72 78 74 72 707 87 79 73 69 86 78 73 69 77 72 69 75 71 68 74 71 68 678 83 75 69 65 82 74 69 65 73 68 65 72 68 65 71 67 65 639 80 71 66 62 79 71 66 62 70 65 62 69 65 62 68 64 61 6010 77 68 63 59 76 67 62 59 67 62 59 66 62 59 65 61 59 57
RC - Ceiling Cavity Reflectance RW - Wall Reflectance
ROO
M C
AVIT
y RA
TIO
rC 80% 70% 50% 30% 10% 0%rW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0%
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 1001 114 111 109 107 111 109 107 105 105 103 102 101 100 99 98 97 96 942 109 104 101 97 107 103 99 96 99 97 94 96 94 92 94 92 90 893 104 98 93 90 102 97 92 89 94 91 88 92 89 86 89 87 85 834 99 92 87 83 98 91 87 83 89 85 82 87 84 81 85 83 80 795 95 87 82 78 93 86 81 78 85 80 77 83 79 76 82 78 76 746 91 83 77 73 89 82 77 73 80 76 73 79 75 72 78 74 72 707 87 79 73 69 86 78 73 69 77 72 69 75 71 68 74 71 68 678 83 75 69 65 82 74 69 65 73 68 65 72 68 65 71 67 65 639 80 71 66 62 79 71 66 62 70 65 62 69 65 62 68 64 61 6010 77 68 63 59 76 67 62 59 67 62 59 66 62 59 65 61 59 57
80
70
60
50
40
30
10020
90
424
849
1273
1697
80
70
60
50
40
30
10020
90
424
849
1273
1697
80
70
60
50
40
30
10020
90
424
849
1273
1697
HV8-leD-21W-MVolT-DiM-Fl-30k-leD-8101-SHZ TEST nO.: 26950 InPuT WATTS: 21 LuMEnS: 972 CRI: 84 EFFICACy: 45 lPW CCT: 3000k SPACInG CRITERIA: 0.8
HV8-leD-21W-MVolT-DiM-Fl-35k-leD-8101-SHZ TEST nO.: 26950 InPuT WATTS: 21 LuMEnS: 1069 CRI: 84 EFFICACy: 50 lPW CCT: 3500k SPACInG CRITERIA: 0.8
HV8-leD-21W-MVolT-DiM-Fl-41k-leD-8101-SHZ TEST nO.: 26950 InPuT WATTS: 21 LuMEnS: 1118 CRI: 84 EFFICACy: 52 lPW CCT: 4100k SPACInG CRITERIA: 0.8
Zonal lumens Summary
Zonal lumens Summary
Zonal lumens Summary
Zone
Zone
Zone
lumens
lumens
lumens
%lamp
%lamp
%lamp
%Fixt
%Fixt
%Fixt
0-300
0-400
0-600
0-900
0-300
0-400
0-600
0-900
0-300
0-400
0-600
0-900
824.27924.09962.14972.42
906.71016.491058.361069.66
947.911062.691106.451118.27
84.89598.9100
84.89598.9100
84.89598.9100
84.89598.9100
84.89598.9100
84.89598.9100
05152535455565758590
05152535455565758590
05152535455565758590
162014801250738893115930.40
1782.551627.781375.33812.0297.5734.3216.177.482.970.440
1863.571701.771437.84848.9310235.8816.907.823.100.460
0
0
0
Candela Tabulation
Candela Tabulation
Candela Tabulation
0-1010-2020-3030-4040-5050-6060-7070-8080-90
0-1010-2020-3030-4040-5050-6060-7070-8080-90
0-1010-2020-3030-4040-5050-6060-7070-8080-90
138.28369.64308.7857.8539.4626.9214.646.19.9
152.1379.3375.29109.827.1314.737.513.19.61
159.02396.54392.35114.7928.3615.47.853.33.64
Zonal lumen Summary
Zonal lumen Summary
Zonal lumen Summary
zone
zone
zone
Lumens
Lumens
Lumens
Beam Angle: 614681012
101.2845.0125.3216.2111.25
5.48.010.713.416.1
BeAM DiA. MeASUreD AT 10% oF nADir F.C.
Distance to Plane
Initial NadirFootcandles
BeamSpread
Beam Angle: 614681012
111.4149.5227.8517.8312.38
5.48.010.713.416.1
BeAM DiA. MeASUreD AT 10% oF nADir F.C.
Distance to Plane
Initial NadirFootcandles
BeamSpread
Beam Angle: 614681012
116.4751.7729.1218.6412.9
5.48.010.713.416.1
BeAM DiA. MeASUreD AT 10% oF nADir F.C.
Distance to Plane
Initial NadirFootcandles
BeamSpread
Candle Power Distribution (Candelas)
Candle Power Distribution (Candelas)
Candle Power Distribution (Candelas)
Angle in Degrees
Angle in Degrees
Angle in Degrees
450
550
650
750
850
450
550
650
750
850
450
550
650
750
850
Average 00
Average 00
Average 00
1387806506328144
1526886556361159
1595926582376166
Average 450
Average 450
Average 450
1387806506328144
1526886556361159
1595926582376166
Average 900
Average 900
Average 900
1387806506328144
1526886556361159
1595926582376166
luminance Data (cd/sq.m)
luminance Data (cd/sq.m)
luminance Data (cd/sq.m)
405
810
1215
1621
446
891
1337
1783
466
932
1398
1864
8 in
cH
LE
D a
rch
itectu
ral D
OW
NliG
ht
18 www.maxilume.com tel 1-877-375-5555 fax 1-877-375-3333
MaXILUMe8 leD oPTiCS Architectural
leD-8101 - REFLECTOR
leD-8115 - REFLECTOR W/ TEMPERED CLEAR GLASS
leD-8113 - BAFFLE W/ TEMPERED CLEAR GLASS
leD-8102 - BAFFLE W/ REFLECTOR
leD-8107 - WALL WASH REFLECTOR
leD-8114 - REFLECTOR W/ FROSTED GLASS LEnS
leD-8112 - BAFFLE W/ FROSTED GLASS LEnS
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH, SCH, SHz
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH
BAFFle FiniSH:
WH, P
ring FiniSH:
WH
BAFFle FiniSH:
WH, P
reFleCTor FiniSH:
CL
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH, SCH, SHz
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH
BAFFle FiniSH:
WH, P
ring FiniSH:
WH
A= 7-1/2B= 9-1/8
A= 7-1/2B= 9-1/8C= 1-3/4
A= 7-1/2B= 9-1/8
A= 7-13/16B= 9-1/8C= 1-3/4
A= 7-13/16B= 9-1/8C= 1-3/4
A= 7-13/16B= 9-1/8C= 1-3/4
A= 7-13/16B= 9-1/8C= 1-3/4
8 in
cH
LE
D a
rch
itectu
ral D
OW
NliG
ht
19submittal form is available online @ http://www.maxilume.com
MaXILUMe 8 leD oPTiCSArchitectural
leD-8125 - CEnTRAL ETCHED FLOAT GLASS
leD-8121 - STARDuST DECO RInG GLASS
leD-8123 - PRISM DECO RInG GLASS
leD-8122 - EuRO DECO RInG GLASS
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH
leD-8109 - DECO GLASS REFLECTOR
leD-8110 - DOuBLE RInG GLASS
leD-8111 - TRIPLE RInG GLASS
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH, SHz
glASS FiniSH:
BLuE, RED, GREEn, FROST
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH, SHz
glASS FiniSH:
BLuE, RED, GREEn, FROST
reFleCTor FiniSH:
CL, WT, MB, SHz, W
ring FiniSH:
WH, SHz
glASS FiniSH:
BLuE, RED, GREEn, FROST
A= 7-1/2B= 9-1/8C= 1-1/4
A= 7-1/2B= 9-1/8C= 1-1/4
A= 7-1/2B= 9-1/8C= 1-1/4
A= 7-1/2B= 9-1/8C= 1-1/4
A= 7-1/2B= 9-1/8C= 1-1/4
A= 7-1/2B= 9-1/8C= 1-3/4
A= 7-1/2B= 9-1/8C= 2-1/4
8 in
cH
LE
D a
rch
itectu
ral D
OW
NliG
ht
oPTiCS Anyone can mount a chip to a heat sink and make a downlight. gather the light scattered by the LED chip, shape it into a functional beam with state of the art reflectors, integrate the light through a smooth lens to minimize brightness, then top it all of with a glare reducing cone that has a 45-degree cut-off. now you have the Elite engineered, superior quality, light engine; consuming less than 14 watts and producing over 600 lumens.
DUrABiliTY Die-cast aluminum housing and heat management system are engineered for extremely long life and service period. Heat sink is attached to top of housing. The LED light engine is attached to the die-cast heat sink and is easily replaceable and upgradable. Without proper heat management, any LED luminaire will fail. Our die-cast system pulls the heat form the LED chip, allowing continued cool operation for years. Life tests have shown the Elite light engine output will be maintained at 70% of initial at 50,000 hours of operation. Our LED driver is rated for 50 to 60 Htz at 120v input, produces less than 10% THD, has a power factor between 0.90 and 1.00 and is thermally protected for additional safety. Elites driver is installed on the junction box cover so it may be serviced from below the ceiling. In installations of 277v, we offer a step down transformer options that is field installable.
rePeATABle Repeatability means quality. From our chip selection process, to our driver, to the thermal management, the Elite LED Module is engineered for quality. All Elite LED luminaries are rated at 85+ CRI and 3,000 degrees Kelvin, as rated and tested to LM-79 and LM-80 standards by an outside laboratory, California Title-24-2008 and Energy Star compliance are standard. Our stringent chip specifications require only those chips that produce no ultra violet and virtually no infrared.
DiMMABle The Elite LED lighting system is fully dimmable down to 15%. no extra equipment or complicated electronics are required, simply install on a circuit using a standard incandescent wall dimmer. Applications that will be three or fewer luminaires or applications that required dimming down to 5% or in applications where more than one dimmer can control the luminaires (daylight harvesting, programmed controls, etc.) will require load compensating dimmers.
oUr WorD The Elite LED lighting system is warranted for 3 years. As a system, we stand behind the entire Elite products from housing to bar hangers.
A. MoUnTing BrACkeT - Constructed from 16-gauge steel. Can be installed with 3/4 or 1-1/2 lathing channel, 1/2 EMT, or with optional C-channel mounting bars (Part# BP31) ordered separately. Housing can be adjusted from the inside of the ceiling.
B. reTAining SPringS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation.
C. MoUnTing FrAMe - Die-formed construction for maximum heat dissipation and rust protection.
D. JUnCTion BoX UL Listed for through-branch circuit wiring, provided with four knockouts, one knockout and four Romex knockouts with true pry-out slots and strain clamps. Designed for straight through conduit runs. Driver is installed on the junction box cover so it may be serviced from below the ceiling.
e. THerMAl ProTeCTion Standard thermal protection device guards against improper installation and misuse of insulation material.
oPTiCS:
F. reFleCTor - Self-flanged .050 aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.
g. lenS - Choice of either tempered clear, tempered frosted lens fastened with two torsion springs.
H. Air-SHUT Provided with gasket to prevent airflow from heated or air conditioned spaces. Meets or exceeds all national air flow requirements.
Ul liSTeD c-UL-us listed for Damp location. / c-UL-us listed for feed Through Wiring.
20 www.maxilume.com tel 1-877-375-5555 fax 1-877-375-3333
Architectural MaXILUMeHH4SQ-leD 4 leD SQUAre ArCHiTeCTUrAl DoWnligHT
Height = 5-1/2
Trim Aperture = 4-1/2
Cut-out = 5-1/8
Trim Outside Dia. = 5-3/4
Width = 7-3/4
Length = 7-1/8
Max. Length = 10
A
B
C
D
E
F
G
InPuT VOLT. InPuT FREQ. InPuT CuR. LED DRIVER CuR. InPuT POWER LED POWER THD POWER FACTOR120V 60Hz 200mA 1250mA 13.89W(+/-5%) 14W 9% >0.9
PEnDInG
4 Square LED dedicated new Construction housing with integral LED heat management casting and driver (installed on junction box). Consuming less than 14 watts and producing over 600 usable lumens. Lighting is smooth and comfortable while using 75% less energy than the equivalent 65w BR30 and 25% less than the common 18w CFL. Plus, the eco-friendly Elite Lighting LED system features 70% lumen maintenance at 50,000 hours life, with California Title-24-2008 compliance and Energy Star Rating (Pending).
FeATUreSGreater light output than an 18w CFL or a 65w BR30 while consuming less than 14w of power. Elite LED luminaires are ideally suited for use in hospitality, health care, commercial, institution, retail and residential applications.
TYPeHH4SQ-LED
WATTAgeo 14W
VolTAgeo 120Vo 277V
DriVero DIMDimmingoPTiono EMgo BP31C-channel
TriMo LED-4601o LED-4617o LED-4614o LED-4615
reFleC.o CLo WTo MBo SHzo W
Coloro 27Ko 30Ko 35Ko 41Ko 50K
iTeM SeleCTor: (Please check the boxes below for the option desired)
Example: HH4SQ-leD-14W-120V-DiM-30k
4 in
cH
LE
D a
rch
itectu
ral D
OW
NliG
ht
21submittal form is available online @ http://www.maxilume.com
A = 3-1/8B = 5-3/4C = 4-5/8
A = 3-1/8B = 5-3/4C = 4-5/8
A = 3-1/8B = 5-3/4C = 4-5/8
A = 3-1/8B = 5-3/4C = 4-5/8
leD-4601-Cl - REFLECTOR
leD-4614-Cl - REFLECTOR WITH FROSTED GLASS LEnS
leD-4615-Cl - REFLECTOR WITH TEMPERED GLASS LEnS
leD-4617-Cl - WALL WASH REFLECTOR WITH LEnS
MaXILUMe 4 leD SQUAre oPTiCSArchitectural
reFleCTor FiniSH:
ring FiniSH:
WH
CL WT MB SHz W
reFleCTor FiniSH:
ring FiniSH:
WH
CL WT MB SHz W
reFleCTor FiniSH:
ring FiniSH:
WH
CL WT MB SHz W
reFleCTor FiniSH:
ring FiniSH:
WH
CL WT MB SHz W
4 in
cH
LE
D a
rch
itectu
ral D
OW
NliG
ht
22 www.maxilume.com tel 1-877-375-5555 fax 1-877-375-3333
Architectural MaXILUMe
DUrABiliTY - Without proper heat management, any LED luminaire will fail. Our die-cast system pulls the heat from the LED chip, allowing continued cool operation for years. Life tests have shown the 6 watt MAXILuME LED output will be maintained at 70% of initial lumens at 50,000 hours of operation.
DriVer - Our LED driver is rated for 50 to 60 Htz at 120v input, produces less than 10% THD, has a power factor between 0.90 and 1.00 and is thermally protected for additional safety. MAXILUMEs driver is installed on the junction box cover, it is easily accessible for serviced from below the ceiling. Additionally, a 277v options is available.
rePeATABle - Repeatability means quality. From our chip selection process, to our driver, to the thermal management, the 6 watt MAXILuME LED is engineered for quality. Our superior design allows for installation in construction that requires the MAXILuME Air-Shut system. All MAXILuME LED luminaries are rated at 85+ CRI and 3,000 degrees Kelvin, as rated and tested to LM-79 and LM-80 standards by an outside laboratory, and meets the California Title-24 compliance standards. Our stringent chip specifications require only those chips that produce no ultra violet and virtually no infrared.
DiMMABle - The MAXILUME LED lighting system is fully dimmable down to 15%. no extra equipment or complicated electronics are required, simply install on a circuit using a standard incandescent wall dimmer. Applications that will be three or fewer luminaires or applications that required dimming down to 5% or in applications where more than one dimmer can control the luminaires (daylight harvesting, programmed controls, etc.) will require load compensating dimmers.
oUr WorD - The H3-LED-6W eco-friendly MAXILuME LED system is warranted for 3 years.
A. HoUSing Die-formed aluminum and galvanized steel for maximum heat dissipation and rust protection. Housing adjusts vertically in plaster frame to accommodate 1/2 to 1-3/8 thick ceiling. Designed for new construction installations and is suitable for use in ceilings where insulation is kept 3 inches from housing. May be installed in 2 x 6 joist construction.
B. MoUnTing BrACkeT Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28. Mounting brackets may be adjusted up to 2-3/4 vertically from inside the housing.
C. JUnCTion BoX UL Listed for through-branch circuit wiring, provided with four knockouts, one knockout and four Romex knockouts with integral strain clamps, all knockouts have true pry-out slots. J-box is designed for straight through conduit runs. Driver is installed on the junction box cover so it may be serviced from below the ceiling.
D. THerMAl ProTeCTion Standard thermal protection device guards against improper installation and misuse of insulation material.
e. Air-SHUT Provided with gasket to prevent airflow from heated or air-conditioned spaces. Meets or exceeds all national air flow requirements.
Ul liSTeD c-UL-us listed for Damp location.c-UL-us listed for feed Through Wiring.
3 LED dedicated Architectural new Construction nOn-IC housing with the driver installed on the junction box. Designed for new Construction construction installations and suitable for use in ceilings where insulation is kept 3 inches from housing. The excellent color rendering index of 85+ and realistic color temperature of 3,100 degrees Kelvin confirms that the MAXILuME LED luminaires are ideally suited for use in hospitality, health care, commercial, retail and residential applications. Consuming 6 watts and producing over 350 usable lumens, the lighting is smooth and comfortable while using nearly 80% less energy than the equivalent 25wPAR36. Plus the eco-friendly MAXILUME LED system features 70% lumen maintenance at 50,000 hours life.
FeATUreSGreater light output than a 25w PAR36 while consuming 6 watts of power.
Example: H3-leD-6W-120V-DiM-35k-AT
InPuT VOLT. InPuT FREQ. InPuT CuR. LED DRIVER CuR. InPuT POWER LED POWER THD POWER FACTOR120V 50/60Hz 200mA 480mA 6.6W(+/-5%) 6W 0.9
H3-leD 3 leD ArCHiTeCTUrAl DoWnligHT
Height = 5-1/2Trim Aperture = 3-1/2Cut-out = 3-3/4Trim Outside Dia. = 3-7/8Width = 5-1/2Length = 8
A
B
C
D
e
F
iTeM SeleCTor: (Please check the boxes below for the option desired)TYPeH3-LED
WATTAgeo 6W
VolTAgeo 120Vo 277V
DriVero DIM-Dimming
Air-SHUTAT
3 in
cH
LE
D a
rch
itectu
ral D
OW
NliG
ht
23submittal form is available online @ http://www.maxilume.com
ICR A T E D
ArchitecturalMaXILUMe
DUrABiliTY - Without proper heat management, any LED luminaire will fail. Our die-cast system pulls the heat from the LED chip, allowing continued cool operation for years. Life tests have shown the 6 watt MAXILuME LED output will be maintained at 70% of initial lumens at 50,000 hours of operation.
DriVer - Our LED driver is rated for 50 to 60 Htz at 120v input, produces less than 10% THD, has a power factor between 0.90 and 1.00 and is thermally protected for additional safety. MAXILUMEs driver is installed on the junction box cover, it is easily accessible for serviced from below the ceiling. Additionally, a 277v options is available.
rePeATABle - Repeatability means quality. From our chip selection process, to our driver, to the thermal management, the 6 watt MAXILuME LED is engineered for quality. Our superior design allows for installation in construction that requires the MAXILuME Air-Shut system. All MAXILuME LED luminaries are rated at 85+ CRI and 3,000 degrees Kelvin, as rated and tested to LM-79 and LM-80 standards by an outside laboratory, and meets the California Title-24 compliance standards. Our stringent chip specifications require only those chips that produce no ultra violet and virtually no infrared.
DiMMABle - The MAXILUME LED lighting system is fully dimmable down to 15%. no extra equipment or complicated electronics are required, simply install on a circuit using a standard incandescent wall dimmer. Applications that will be three or fewer luminaires or applications that required dimming down to 5% or in applications where more than one dimmer can control the luminaires (daylight harvesting, programmed controls, etc.) will require load compensating dimmers.
oUr WorD - The H3-LED-IC-6W eco-friendly MAXILuME LED system is warranted for 3 years.
A. HoUSing Housing is IC rated for direct contact with insulation. May be installed in 2 x 8 joist construction. Outer Die-formed aluminum construction for maximum head dissipating air chamber on top of the housing. Junction box could me accessed from inside and outside housing. Inner deep-drawn single piece aluminum construction for maximum heat dissipation and rust protection. Adjusts vertically in plaster frame to accommodate 1/2 to 1-3/8 ceiling.
B. MoUnTing BrACkeT Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28. Mounting brackets may be adjusted up to 2-3/4 vertically from inside the housing.
C. JUnCTion BoX UL Listed for through-branch circuit wiring, provided with four knockouts, one knockout and four Romex knockouts with integral strain clamps, all knockouts have true pry-out slots. J-box is designed for straight through conduit runs. Driver is installed on the junction box cover so it may be serviced from below the ceiling.
D. THerMAl ProTeCTion Standard thermal protection device guards against improper installation and misuse of insulation material.
e. Air-SHUT Provided with gasket to prevent airflow from heated or air- conditioned spaces. Meets or exceeds all national air flow requirements.
Ul liSTeD c-UL-us listed for Damp location.c-UL-us listed for feed Through Wiring.c-UL-us listed for Direct Contact with Insulation
3 LED dedicated Architectural new Construction IC housing with the driver installed on the junction box. Designed for new construction installations and suitable for use in insulation covered ceilings. The excellent color rendering index of 85+ and realistic color temperature of 3,100 degrees Kelvin confirms that the MAXILUME LED luminaires are ideally suited for use in hospitality, health care, commercial, retail and residential applications. Consuming 6 watts and producing over 350 usable lumens, the lighting is smooth and comfortable while using nearly 80% less energy than the equivalent 25wPAR36. Plus, the eco-friendly MAXILuME LED system features 70% lumen maintenance at 50,000 hours life.
FeATUreSGreater light output than a 25w PAR36 while consuming 6 watts of power.
Example: H3-leD-iC-6W-120V-DiM-35k-AT
InPuT VOLT. InPuT FREQ. InPuT CuR. LED DRIVER CuR. InPuT POWER LED POWER THD POWER FACTOR120V 50/60Hz 200mA 480mA 6.6W(+/-5%) 6W 0.9
H3-leD-iC 3 leD ArCHiTeCTUrAl DoWnligHT
Height = 7-1/4Trim Aperture = 3-1/2Cut-out = 3-7/8Trim Outside Dia. = 3-7/8Width = 7-5/8Length = 12-1/4
A
B
C
D
e
F
iTeM SeleCTor: (Please check the boxes below for the option desired)TYPeH3-LED-IC
WATTAgeo 6W
VolTAgeo 120Vo 277V
DriVero DIM-Dimming
Air-SHUTAT
3 in
cH
LE
D a
rch
itectu
ral D
OW
NliG
ht
iTeM SeleCTor: (Please check the boxes below for the option desired)
24 www.maxilume.com tel 1-877-375-5555 fax 1-877-375-3333
Height = 5-1/2Trim Aperture = 3-1/2Cut-out = 3-3/4Trim Outside Dia. = 3-7/8Width = 3-3/4Length = 12-1/2
A
B
C
D
e
F
Architectural MaXILUMe
DUrABiliTY - Without proper heat management, any LED luminaire will fail. Our die-cast system pulls the heat from the LED chip, allowing continued cool operation for years. Life tests have shown the 6 watt MAXILuME LED output will be maintained at 70% of initial lumens at 50,000 hours of operation.
DriVer - Our LED driver is rated for 50 to 60 Htz at 120v input, produces less than 10% THD, has a power factor between 0.90 and 1.00 and is thermally protected for additional safety. MAXILUMEs driver is installed on the junction box cover, it is easily accessible for serviced from below the ceiling. Additionally, a 277v options is available.
rePeATABle - Repeatability means quality. From our chip selection process, to our driver, to the thermal management, the 6 watt MAXILuME LED is engineered for quality. Our superior design allows for installation in construction that requires the MAXILuME Air-Shut system. All MAXILuME LED luminaries are rated at 85+ CRI and 3,000 degrees Kelvin, as rated and tested to LM-79 and LM-80 standards by an outside laboratory, and meets the California Title-24 compliance standards. Our stringent chip specifications require only those chips that produce no ultra violet and virtually no infrared.
DiMMABle - The MAXILUME LED lighting system is fully dimmable down to 15%. no extra equipment or complicated electronics are required, simply install on a circuit using a standard incandescent wall dimmer. Applications that will be three or fewer luminaires or applications that required dimming down to 5% or in applications where more than one dimmer can control the luminaires (daylight harvesting, programmed controls, etc.) will require load compensating dimmers.
oUr WorD - The H3-LED-R-6W eco-friendly MAXILuME LED system is warranted for 3 years.
A. HoUSing Die-formed high temperature painted 22-gauge steel deep-drawn for maximum heat dissipation and rust protection. Designed for new construction installations and is suitable for use in ceilings where insulation is kept 3 inches from housing. May be installed in 2 x 6 joist construction.
B. inSTAllATion For fast and easy installation in existing plaster or mechanical ceilings the housing installs from below the ceiling. Four preinstalled spring clips with secure the housing firmly into ceiling to accommodate different ceiling thicknesses form 1/2 to 1-3/8.
C. JUnCTion BoX UL Listed for through-branch circuit wiring, provided with eight knockouts and four Romex knockouts with true pry-out slots and strain clamps.
D. THerMAl ProTeCTion Standard thermal protection device guards against improper installation and misuse of insulation material.
e. Air-SHUT Provided with gasket to prevent airflow from heated or air-conditioned spaces. Meets or exceeds all national airflow requirements.
Ul liSTeD c-UL-us listed for Damp location.c-UL-us listed for feed Through Wiring.
3 LED dedicated Architectural Remodel nOn-IC housing with the driver installed on the junction box. Designed for remodel construction installations and suitable for use in ceilings where insulation is kept 3 inches from housing. The excellent color rendering index of 85+ and realistic color temperature of 3,100 degrees Kelvin confirms that the MAXILuME LED luminaires are ideally suited for use in hospitality, health care, commercial, retail and residential applications. Consuming 6 watts and producing over 350 usable lumens, the lighting is smooth and comfortable while using nearly 80% less energy than the equivalent 25wPAR36. Plus the eco-friendly MAXILuME LED system features 70% lumen maintenance at 50,000 hours life.
FeATUreSGreater light output than a 25w PAR36 while consuming 6 watts of power.
InPuT VOLT. InPuT FREQ. InPuT CuR. LED DRIVER CuR. InPuT POWER LED POWER THD POWER FACTOR120V 50/60Hz 200mA 480mA 6.6W(+/-5%) 6W 0.9
H3-leD-r 3 leD reMoDel ArCHiTeCTUrAl DoWnligHT
TYPeH3-LED-R
WATTAgeo 6W
VolTAgeo 120Vo 277V
DriVero DIM-Dimming
Air-SHUTAT
Example: H3-leD-r-6W-120V-DiM-AT
3 in
cH
LE
D a
rch
itectu
ral D
OW
NliG
ht
submittal form is available online @ http://www.maxilume.com 25
MaXILUMe 3 leD oPTiCSArchitectural
iTeM SeleCTor: (Please check the boxes below for the option desired)
Example: leD1301-6W-Fl-35k-W-WH
FiniSHo W-WHo P-WHo Sn-Sno CP-CPo Bz-Bz
o P-BK
TYPeLED1301
WATTAgeo 6W
oPTiCSo FL-Flood(Standard)
Coloro 27Ko 30Ko 35Ko 40Ko 50K
leD-1301-6W-Fl-35k-W-WH leD-1301-6W-Fl-35k-P-WH leD-1301-6W-Fl-35k-P-Bk
leD-1301-6W-Fl-35k-Sn-Sn leD-1301-6W-Fl-35k-CP-CP leD-1301-6W-Fl-35k-BZ-BZ
gather the light scattered by the LED chip, shape it into a functional beam with a glare reducing cone that has a 55-degree cut-off. now you have the MAXILUME engineered, superior quality, 3 architectural LED downlight; consuming 6 watts and producing over 342 lumens.
Among the trim options are: white, black, copper, bronze or satin nickel architectural low glare baffle with a variety of trim ring color options. Die-cast aluminum trim and integral heat management system are engineered for extremely long life and service period.
The heat sink extrusion is made from 3001 aluminum and is engineered to be in intimate contact with the die-cast trim. The cast trim has been designed to maximize reflective surface areas while keeping effective heat dissipation a priority.
As technology improves or the needs of a space changes, the MAXILuME architectural 3 LED trim can be upgraded. Simply pull it down from the housing and unplug the quick Ez-disconnect. Putting in a new trim is just as easy and there is no danger of electrical shock. The Ez-connect system eliminates incidental contact and the system is powered by less than 12 volts.
BAFFle FiniSH :
Zonal lumens Summaryzone Lumens %Lamp %Fixt0-300 216.76 n.A. 63.30-400 265.50 n.A. 77.60-600 335.61 n.A. 98.10-900 342.27 n.A. 1000-1800 342.27 n.A. 100
luminance Data (cd/sq.m)
Angle In Average Average AverageDegrees 00 450 900
450 18,668 18,668 18,668 550 903 903 903 650 1225 1225 1225 750 2000 2000 2000 850 5940 5940 5940
TRIM: leD-1301-6W-Fl-35k-W-WH TEST nO.: lli 0909-17A1 LuMEnS: 342 SPACInG CRITERIA: .14
Candle Power Distribution (Candelas)
TriM/ring FiniSH :BAFFle FiniSH :
Total Luminaire Efficiency = n.A.%
Photometric Multiplier 1.0 Photometric Multiplier .75 Photometric Multiplier .75
Photometric Multiplier .92 Photometric Multiplier .87 Photometric Multiplier .85
THE MOST uP TO DATE PHOTOMETRIC DATA IS AVAILABLE OnLInE @ WWW.MAXILuME.COM
BZ CP Sn WH PBROnzE COPPER SATIn
nICKELWHITE BLACK
BkBLACK
BZBROnzE
CHCHROME
CPCOPPER
PBWHWHITE
SnSATIn nICKEL
POLISH BRASS
3 in
cH
LE
D a
rch
itectu
ral D
OW
NliG
ht
26 www.maxilume.com tel 1-877-375-5555 fax 1-877-375-3333
MaXILUMe3 leD oPTiCS Architectural
leD-1302-6W-Fl-35k-Cl-WH leD-1302-6W-Fl-35k-CP-WH
leD-1302-6W-Fl-35k-rg-WH
leD-1302-6W-Fl-35k-Cl-CH leD-1302-6W-Fl-35k-CP-CP
leD-1302-6W-Fl-35k-rg-PBleD-1302-6W-Fl-35k-Cl-Sn
gather the light scattered by the LED chip, shape it into a functional beam with a glare reducing cone that has a 55-degree cut-off. now you have the MAXILUME engineered, superior quality, 3 architectural LED downlight; consuming 6 watts and producing over 357 lumens.
Among the trim options are: architectural flood reflector with clear anodized (chrome), white, black, copper, satin nickel or gold with a variety of trim ring color options. Die-cast aluminum trim and integral heat management system are engineered for extremely long life and service period.
The heat sink extrusion is made from 3001 aluminum and is engineered to be in intimate contact with the die-cast trim. The cast trim has been designed to maximize reflective surface areas while keeping effective heat dissipation a priority.
As technology improves or the needs of a space changes the MAXILUME architectural 3 LED trim can be upgraded. Simply pull it down from the housing and unplug the quick Ez-disconnect. Putting in a new trim is just as easy and there is no danger of electrical shock. The Ez-connect system eliminates incidental contact and the system is powered by less than 12 volts.
Trim - MAXilUMe engineered, superior quality, 3 architectural leD downlight
3 leD l1302 reFleCTor
Photometric Multiplier 1.0 Photometric Multiplier .90
leD-1302-6W-Fl-35k-Sn-SnPhotometric Multiplier .87Photometric Multiplier 1.0 Photometric Multiplier .90
Photometric Multiplier .90Photometric Multiplier 1.0
leD-1302-6W-Fl-35k-Sn-WHPhotometric Multiplier .87
Photometric Multiplier .90
Zonal lumens Summaryzone Lumens %Lamp %Fixt0-300 223.45 n.A. 62.50-400 275.74 n.A. 77.10-600 351.44 n.A. 98.20-900 357.44 n.A. 1000-1800 357.44 n.A. 100
luminance Data (cd/sq.m)
Angle In Average Average AverageDegrees 00 450 900
450 20,132 20,132 20,132 550 1354 1354 1354 650 1225 1225 1225 750 2000 2000 2000 850 2970 2970 2970
TRIM: leD-1302-6W-Fl-35k-Cl-WH TEST nO.: lli 0909-17A3 LuMEnS: 357 SPACInG CRITERIA: .14
Candle Power Distribution (Candelas)
Total Luminaire Efficiency = n.A.%
THE MOST uP TO DATE PHOTOMETRIC DATA IS AVAILABLE OnLInE @ WWW.MAXILuME.COM
3 in
cH
LE
D a
rch
itectu
ral D
OW
NliG
ht
submittal form is available online @ http://www.maxilume.com 27
MaXILUMe 3 leD oPTiCSArchitectural
iTeM SeleCTor: (Please check the boxes below for the option desired)
Example: leD1302-6W-Fl-35k-Cl-WH
FiniSHo CL-WHo CP-WHo W-WHo Bz-Bzo Sn-WHo Rg-WHo MB-WH
o CL-CHo CP-CP
o Sn-Sno RG-PBo MB-BK
o CL-SnTYPeLED1302
WATTAgeo 6W
oPTiCSo FL-Flood(Standard)
Coloro 27Ko 30Ko 35Ko 40Ko 50K
leD-1302-6W-Fl-35k-MB-WH leD-1302-6W-Fl-35k-MB-Bk
3 leD l1302 reFleCTor
leD-1302-6W-Fl-35k-W-WHPhotometric Multiplier .95Photometric Multiplier .77 Photometric Multiplier .77
leD-1302-6W-Fl-35k-BZ-BZ
Photometric Multiplier .87
reFleCTor FiniSH :
CP rg BZMB SnClCLEAR(CHROME)
COPPER gOLD SATInnICKEL
BROnzE
TriM/ring FiniSH :
BkBLACK
BZBROnzE
CHCHROME
CPCOPPER
PBWHWHITE
SnSATIn nICKEL
POLISH BRASS
BLACKWWHITE
3 in
cH
LE
D a
rch
itectu
ral D
OW
NliG
ht
28 www.maxilume.com tel 1-877-375-5555 fax 1-877-375-3333
ArchitecturalH4-leD 4 leD ArCHiTeCTUrAl DoWnligHT
MaXILUMe
DUrABiliTY - Without proper heat management, any LED luminaire will fail. Our die-cast system pulls the heat from the LED chip, allowing continued cool operation for years. Life tests have shown the 11 watt MAXILUME LED output will be maintained at 70% of initial lumens at 50,000 hours of operation.
DriVer - Our LED driver is rated for 50 to 60 Htz at 120v input, produces less than 10% THD, has a power factor between 0.90 and 1.00 and is thermally protected for additional safety. MAXILUMEs driver is installed on the junction box cover, it is easily accessible for serviced from below the ceiling. Additionally, a 277v options is available.
rePeATABle - Repeatability means quality. From our chip selection process, to our driver, to the thermal management, the 11 watt MAXILUME LED is engineered for quality. Our superior design allows for installation in construction that requires the MAXILuME Air-Shut system. All MAXILuME LED luminaries are rated at 85+ CRI and 3,000 degrees Kelvin, as rated and tested to LM-79 and LM-80 standards by an outside laboratory, and meets the California Title-24 compliance standards. Our stringent chip specifications require only those chips that produce no ultra violet and virtually no infrared.
DiMMABle - The MAXILUME LED lighting system is fully dimmable down to 15%. no extra equipment or complicated electronics are required, simply install on a circuit using a standard incandescent wall dimmer. Applications that will be three or fewer luminaires or applications that required dimming down to 5% or in applications where more than one dimmer can control the luminaires (daylight harvesting, programmed controls, etc.) will require load compensating dimmers.
oUr WorD - The H4-LED-11W eco-friendly MAXILUME LED system is warranted for 3 years.
A. HoUSing - Die-formed aluminum and galvanized steel for maximum heat dissipation and rust protection. Housing adjusts vertically in plaster frame to accommodate 1/2 to 1-3/8 thick ceiling. Designed for new construction installations and is suitable for use in ceilings where insulation is kept 3 inches from housing. May be installed in 2 x 6 joist construction.
B. MoUnTing BrACkeT Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28. Mounting brackets may be adjusted up to 2-3/4 vertically from inside the housing.
C. JUnCTion BoX UL Listed for through-branch circuit wiring, provided with four knockouts, one knockout and four Romex knockouts with integral strain clamps, all knockouts have true pry-out slots. J-box is designed for straight through conduit runs. Driver is installed on the junction box cover so it may be serviced from below the ceiling.
D. THerMAl ProTeCTion Standard thermal protection device guards against improper installation and misuse of insulation material.
e. Air-SHUT Provided with gasket to prevent airflow from heated or air-conditioned spaces. Meets or exceeds all national airflow requirements.
Ul liSTeD c-UL-us listed for Damp location.c-UL-us listed for feed Through Wiring.
FeATUreSGreater light output than a 13w CFL, a 20w MR16 or a 50w BR20 while consuming 11 watts of power.
4 LED dedicated Architectural new Construction non-IC housing with the driver installed on the junction box. Designed for new construction installations and suitable for use in ceilings where insulation is kept 3 inches from housing. The excellent color rendering index of 85+ and realistic color temperature of 3,100 degrees Kelvin confirms that the MAXILUME LED luminaires are ideally suited for use in hospitality, health care, commercial, retail and residential applications. Consuming 11 watts and producing over 465 usable lumens, the lighting is smooth and comfortable while using nearly 80% less energy than the 50w BR20, 50% less energy than a 20w MR16 and 25% less than the common 13w CFL. Plus, the eco-friendly MAXILuME LED system features 70% lumen maintenance at 50,000 hours life.
TYPeH4-LED
WATTAgeo 11W
VolTAgeo 120Vo 277V
DriVero DIM-Dimming
Air-SHUTAT
iTeM SeleCTor: (Please check the boxes below for the option desired)
InPuT VOLT. InPuT FREQ. InPuT CuR. LED DRIVER CuR. InPuT POWER LED POWER THD POWER FACTOR120V 50/60Hz 200mA 900mA 12W(+/-5%) 11W 9% >0.9
Height = 5-1/2Trim Aperture = 4Cut-out = 4-3/8Trim Outside Dia. = 4-7/8Width = 5-1/2Length = 8
A
B
C
D
e
F
Example: H4-leD-11W-120V-DiM-AT
4 in
cH
LE
D a
rch
itectu
ral D
OW
NliG
ht
DUrABiliTY - Without proper heat management, any LED luminaire will fail. Our die-cast system pulls the heat from the LED chip, allowing continued cool operation for years. Life tests have shown the 11 watt MAXILUME LED output will be maintained at 70% of initial lumens at 50,000 hours of operation.
DriVer - Our LED driver is rated for 50 to 60 Htz at 120v input, produces less than 10% THD, has a power factor between 0.90 and 1.00 and is thermally protected for additional safety. MAXILUMEs driver is installed on the junction box cover, it is easily accessible for serviced from below the ceiling. Additionally, a 277v options is available.
rePeATABle - Repeatability means quality. From our chip selection process, to our driver, to the thermal management, the 11 watt MAXILUME LED is engineered for quality. Our superior design allows for installation in construction that requires the MAXILuME Air-Shut system. All MAXILuME LED luminaries are rated at 85+ CRI and 3,000 degrees Kelvin, as rated and tested to LM-79 and LM-80 standards by an outside laboratory, and meets the California Title-24 compliance standards. Our stringent chip specifications require only those chips that produce no ultra violet and virtually no infrared.
DiMMABle - The MAXILUME LED lighting system is fully dimmable down to 15%. no extra equipment or complicated electronics are required, simply install on a circuit using a standard incandescent wall dimmer. Applications that will be three or fewer luminaires or applications that required dimming down to 5% or in applications where more than one dimmer can control the luminaires (daylight harvesting, programmed controls, etc.) will require load compensating dimmers.
oUr WorD - The H4-LED-IC-11W eco-friendly MAXILUME LED system is warranted for 3 years.
A. HoUSing - Housing is IC rated for direct contact with insulation. May be installed in 2 x 8 joist construction. Outer Die-formed aluminum construction for maximum head dissipating air chamber on top of the housing. Junction box could me accessed from inside and outside housing. Inner deep-drawn single piece aluminum construction for maximum heat dissipation and rust protection. Adjusts vertically in plaster frame to accommodate 1/2 to 1-3/8 ceiling.
B. MoUnTing BrACkeT Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28. Mounting brackets may be adjusted up to 2-3/4 vertically from inside the housing.C. JUnCTion BoX UL Listed for through-branch circuit wiring, provided with four knockouts, one knockout and four Romex knockouts with integral strain clamps, all knockouts have true pry-out slots. J-box is designed for straight through conduit runs. Driver is installed on the junction box cover so it may be serviced from below the ceiling.
D. THerMAl ProTeCTion Standard thermal protection device guards against improper installation and misuse of insulation material.
e. Air-SHUT Provided with gasket to prevent airflow from heated or air-conditioned spaces. Meets or exceeds all national airflow requirements.
Ul liSTeD c-UL-us listed for Damp location.c-UL-us listed for feed Through Wiring.c-UL-us listed for Direct Contact with Insulation
29submittal form is available online @ http://www.maxilume.com
Architectural H4-leD-iC 4 leD ArCHiTeCTUrAl DoWnligHT
ICR A T E D
MaXILUMe
FeATUreSGreater light output than a 13w CFL, a 20w MR16 or a 50w BR20 while consuming 11 watts of power.
4 LED dedicated Architectural new Construction IC housing with the driver installed on the junction box. Designed for new construction installations and suitable for use in insulation covered ceilings. The excellent color rendering index of 85+ and realistic color temperature of 3,100 degrees Kelvin confirms that the MAXILUME LED luminaires are ideally suited for use in hospitality, health care, commercial, retail and residential applications. Consuming 11 watts and producing over 465 usable lumens, the lighting is smooth and comfortable while using nearly 80% less energy than the 50w BR20, 50% less energy than a 20w MR16 and 25% less than the common 13w CFL. Plus, the eco-friendly MAXILuME LED system features 70% lumen maintenance at 50,000 hours life.
InPuT VOLT. InPuT FREQ. InPuT CuR. LED DRIVER CuR. InPuT POWER LED POWER THD POWER FACTOR120V 50/60Hz 200mA 900mA 12W(+/-5%) 11W 9% >0.9
Height = 7-1/4Trim Aperture = 4Cut-out = 4-3/8Trim Outside Dia. = 4-7/8Width = 7-5/8Length = 12-1/4
A
B
C
D
e
F
TYPeH4-LED-IC
WATTAgeo 11W
VolTAgeo 120Vo 277V
DriVero DIM-Dimming
Air-SHUTAT
iTeM SeleCTor: (Please check the boxes below for the option desired)
Example: H4-leD-iC-11W-120V-DiM-AT
4 in
cH
LE
D a
rch
itectu
ral D
OW
NliG
ht
30 www.maxilume.com tel 1-877-375-5555 fax 1-877-375-3333
ArchitecturalH4-leD-r 4 leD reMoDel ArCHiTeCTUrAl DoWnligHT
A
B
C
D
e
F
MaXILUMe
DUrABiliTY - Without proper heat management, any LED luminaire will fail. Our die-cast system pulls the heat from the LED chip, allowing continued cool operation for years. Life tests have shown the 11 watt MAXILUME LED output will be maintained at 70% of initial lumens at 50,000 hours of operation.
DriVer - Our superior design allows for installation in construction that requires the MAXILuME Air-Shut system. Our LED driver is rated for 50 to 60 Htz at 120v input, produces less than 10% THD, has a power factor between 0.90 and 1.00 and is thermally protected for additional safety. MAXILUMEs driver is installed on the junction box cover, it is easily accessible for serviced from below the ceiling. Additionally, a 277v options is available.
rePeATABle - Repeatability means quality. From our chip selection process, to our driver, to the thermal management, the 11 watt MAXILUME LED is engineered for quality. Our superior design allows for installation in construction that requires the MAXILuME Air-Shut system. All MAXILuME LED luminaries are rated at 85+ CRI and 3,000 degrees Kelvin, as rated and tested to LM-79 and LM-80 standards by an outside laboratory, and meets the California Title-24 compliance standards. Our stringent chip specifications require only those chips that produce no ultra violet and virtually no infrared.
DiMMABle - The MAXILUME LED lighting system is fully dimmable down to 15%. no extra equipment or complicated electronics are required, simply install on a circuit using a standard incandescent wall dimmer. Applications that will be three or fewer luminaires or applications that required dimming down to 5% or in applications where more than one dimmer can control the luminaires (daylight harvesting, programmed controls, etc.) will require load compensating dimmers.
oUr WorD - The H4-LED-R-11W eco-friendly MAXILUME LED system is warranted for 3 years.
A. HoUSing Die-formed high temperature painted 22-gauge steel deep-drawn for maximum heat dissipation and rust protection. Designed for new construction installations and is suitable for use in ceilings where insulation is kept 3 inches from housing. May be installed in 2 x 6 joist construction.
B. inSTAllATion For fast and easy installation in existing plaster or mechanical ceilings the housing installs from below the ceiling. Four preinstalled spring clips with secure the housing firmly into ceiling to accommodate different ceiling thicknesses form 1/2 to 1-3/8.
C. JUnCTion BoX UL Listed for through-branch circuit wiring, provided with eight knockouts and four Romex knockouts with true pry-out slots and strain clamps.
D. THerMAl ProTeCTion Standard thermal protection device guards against improper installation and misuse of insulation material.
e. Air-SHUT Provided with gasket to prevent airflow from heated or air-conditioned spaces. Meets or exceeds all national airflow requirements.
Ul liSTeD c-UL-us listed for Damp location.c-UL-us listed for feed Through Wiring.
FeATUreSGreater light output than a 13w CFL, a 20w MR16 or a 50w BR20 while consuming 11 watts of power.
4 LED dedicated Architectural Remodel nOn-IC housing with the driver installed on the j