23
©2011 AWS Truepower, LLC ALBANY • BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | [email protected] OVERVIEW OF SIX COMMERCIAL AND RESEARCH WAKE MODELS FOR LARGE OFFSHORE WIND FARMS EWEA CONFERENCE COPENHAGEN, DENMARK APRIL 18, 2012 PHILIPPE BEAUCAGE, SR. RESEARCH SCIENTIST MICHAEL BROWER, CHIEF TECHNICAL OFFICER NICK ROBINSON, DIRECTOR OF OPENWIND CHARLES ALONGE, R&D SPECIALIST

©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | [email protected] OVERVIEW OF SIX COMMERCIAL

Embed Size (px)

Citation preview

Page 1: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC

ALBANY • BARCELONA • BANGALORE

463 NEW KARNER ROAD | ALBANY, NY 12205awstruepower.com | [email protected]

OVERVIEW OF SIX COMMERCIAL AND RESEARCH WAKE MODELS FOR LARGE OFFSHORE WIND FARMS

EWEA CONFERENCECOPENHAGEN, DENMARK

APRIL 18, 2012

PHILIPPE BEAUCAGE, SR. RESEARCH SCIENTISTMICHAEL BROWER, CHIEF TECHNICAL OFFICER

NICK ROBINSON, DIRECTOR OF OPENWIND CHARLES ALONGE, R&D SPECIALIST

Page 2: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

Presentation Overview Background

Validation of different modeling approaches: Standard wake models Hybrid model using IBL approach Linear CFD-RANS model Non-linear CFD-RANS model Large-Eddy Simulations

Results Nysted wind farm Horns Rev wind farm

Conclusions

Acknowledgments J. Garza and colleagues at DONG Energy R. Barthelmie at Indiana University DONG Energy, Vattenfall and E.On P.-E. Réthoré at the Risø /DTU

Page 3: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

Background

• Wind power projects have been steadily growing in size.

1000 MW + wind farms are now being proposed.

• Standard wake models (Modified Park, Eddy Viscosity, etc.) used in engineering were developed two decades ago for modest-size wind farms.

• They do not account for the interaction between multiple turbine wakes, or between wakes and the planetary boundary layer (PBL)

both of which become relatively more important in deep arrays i.e. large wind farms.

→ Serious doubts regarding the validity of standard wake models applied to large wind farms (“deep arrays”)

Page 4: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

BackgroundGOAL : To validate and improve our estimated wake losses and energy

productions.

QUESTIONS : How to capture the interaction between multiple turbine wakes

(deep array effect) as well as between wakes and the PBL?

METHODOLOGY : Validate different modeling approaches Standard engineering wake models Hybrid model using IBL approach Linear CFD-RANS model Non-linear CFD-RANS model Large-Eddy Simulations

PBL = Planetary Boundary Layer

Page 5: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

Wind Turbine Aerodynamic: Actuator Disk Theory• Vdisk = (1-a) · V0

• Vwake = (1-2a) · V0

• a ≡ axial induction factor

Page 6: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

Overview of wake modeling approaches• Standard wake models

Park / Modified Park (Jensen 1983, Katic et al. 1986) Eddy Viscosity (Ainslie 1988)

• Hybrid wake model based on IBL approaches Deep-Array Wake Model (Brower and Robinson 2009) Large Wind Farm Model (Schlez and Neubert 2009)

• Physics-based models Numerical Weather Prediction (NWP) Computational Fluid Dynamics (CFD)

Reynolds-Averaged Navier-Stokes(RANS) Detached-Eddy Simulation (DES) Large-Eddy Simulation (LES)

Turbine parameterization Actuator disk model (Rankine-Froude, BEM, etc.) Actuator line model etc.

Page 7: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

Wake ModelsName Software Type Commercial/

ResearchPark AWS openWind,

WAsP,WindPro,Etc.

Engineering (Jensen/Katic)

C

Eddy Viscosity AWS openWind,WindFarmer,Etc.

Engineering/RANS (Ainslie)

C

Deep-Array Wake Model

AWS openWind IBL approach and engineering

C/R

Fuga WAsP Linear RANS C/RWindModeller Ansys RANS C/RARPS ARPS LES R

Page 8: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

Park model

• Based on a balance of momentum to model single wakes (Jensen 1983, Katic 1986)

• Assumes an initial velocity deficit immediately behind the turbine rotor, calculated from the turbine’s thrust coefficient (Ct) and an empirically determined wake-decay constant (k)

• The wake-decay constant sets the linear rate of expansion of the wake with distance downstream

Page 9: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

Eddy Viscosity model

• Based on Navier-Stokes equations with simplifying assumptions (Ainslie 1988)– No pressure gradient term;– Beyond 5 rotor diameter downstream the wake profile is roughly

Gaussian and the centerline deficit decays monotonically;– Etc.

• Valid only at distances farther than ~ 2-3 rotor diameters downstream of a turbine.

• The model runs fast on any PC → suitable for turbine layout optimization.• An industry standard for calculating wake losses

Page 10: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

• Hybrid model based on internal boundary layer (IBL) growth and Eddy Viscosity (Brower and Robinson 2009)

• Assign a roughness to each turbine and assume that an internal boundary layer develops at the bottom and top of the turbine rotor (based on Frandsen 2007).

• Couple the IBL growth model with Eddy Viscosity• The model runs fast on any PC → suitable for turbine layout optimization• An industry standard for calculating wake losses (openWind).

Deep Array Wake Model (DAWM)

http://www.daviddarling.info/encyclopedia/B/AE_blades.html

Page 11: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

Fuga model

• Linear RANS model + actuator disk developed by Risø/DTU• Designed for sites with homogeneous terrain and roughness• Fully integrated within WAsP

Garza, J. et al. (2011). “Evaluation of two novel wake models in offshore wind farms ". Proceedings from the EWEA Offshore conference, 29 Nov. - 1 Dec 2011. 10 p.

Page 12: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

WindModeller model

• RANS model using a k- turbulence closure. • Based on the commercial RANS software Ansys CFX. • Added of an actuator disk to model wakes. • Does not take atmospheric stability into account (at the moment)

Garza, J. et al. (2011). “Evaluation of two novel wake models in offshore wind farms ". Proceedings from the EWEA Offshore conference, 29 Nov. - 1 Dec 2011. 10 p.

Page 13: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

Advanced Regional Prediction System (ARPS)

• Numerical Weather Prediction (NWP) model and Large-Eddy Simulation (LES)• Fully compressible, non-hydrostatic Navier-Stokes equations

– Dynamic model– Conservation of mass, momentum and energy

• Complete suite of physics parameterization schemes– 1.5-order turbulence closure: k-l model

• Initial and boundary conditions provided by a) an external data source (e.g. NAM analyses) or

b) an atmospheric sounding.

Page 14: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

Actuator Disk Implementation in ARPS

Based on the actuator disk theory (Adams et al. 2007, Réthoré et al. 2008) , a wind turbine is modeled as :

Drag force due to the thrust force that a turbine exert on the upwind flow.

Source of turbulent kinetic energy representing the sub-grid scale turbulence due to the turbine-induced wakes. It includes the effects of the blade tip, blade shed and root vortices. Ct(|u|) = thrust coefficient,

Cp(|u|) = power coefficient, u = wind speed vectors, = air density,A = area swept by the blades.

14

Page 15: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

Nysted Wind Farm

• Number of turbines : 72• Array:

8 × 9• Turbine:

2.3 MW• Rated capacity:

166 MW• Rotor diameter (D):

82.4 m• Hub Height:

69 m• Distance between turbines: 7D• Water depth:

6-14 m• Distance from land:

10 km

Nysted, Denmark

Page 16: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

Results: Nysted

• The Park and EV model significantly overestimates the production (underestimates the wake loss) beginning at about the 4th column from the front.

• DAWM performs very well.• All models show better accuracy over

30° wide sector than 5°.

Page 17: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

Horns Rev Wind Farm

• Number of turbines : 80• Array:

8 × 10• Turbine:

2 MW• Rated capacity:

160 MW• Rotor diameter (D):

80 m• Hub Height:

70 m• Distance between turbines: 7D• Water depth:

6-14 m• Distance from land:

14-20 km

Horns Rev, Denmark

Page 18: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

Results: Horns Rev (Part 1)

• The Park and EV model significantly overestimates the production (underestimates the wake loss) beginning at about the 4th column from the front.

• DAWM performs very well.• ARPS performs relatively well but not

for the 8 m/s case.

Page 19: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

Results: Horns Rev (part 2)

These results were kindly provided by Garza et al. (2011). “Evaluation of two novel wake models in offshore wind farms”. Proceedings from the EWEA Offshore conference, 29 Nov. - 1 Dec 2011. 10 p.

• The Fuga and WindModeller models align very well with the observed normalized power production within the third column of turbines .

• The Park model performs better at Horns Rev than it did at Nysted but, as with the EV model, the profile remains relatively flat after the fourth column

• The Jensen and Fuga models show better accuracy over 30° wide sector than 5°.

Page 20: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

ARPS → Large-Eddy Simulationwind speed

Page 21: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

ARPS → Large-Eddy Simulationwind speed

m/s

Page 22: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

Conclusion

• The Park and Eddy Viscosity models works well within the first 3 columns. However, they are typically not able to capture the wake losses beyond the 3rd column from the front (→ deep array effect).

• DAWM captures the wake losses in large array much better than either the EV or Park model.

• The Fuga and Windmodeller models also showed promise, though a full comparison was not possible.

• ARPS performed reasonably well for these initial tests and merits further research

• Need more detailed power production data with concurrent meteorological conditions (e.g. IEA WakeBench experiment)

Acknowledgments J. Garza and colleagues at DONG Energy R. Barthelmie at Indiana University DONG Energy, Vattenfall and E.On P.-E. Réthoré at the Risø /DTU

Page 23: ©2011 AWS Truepower, LLC ALBANY BARCELONA BANGALORE 463 NEW KARNER ROAD | ALBANY, NY 12205 awstruepower.com | info@awstruepower.com OVERVIEW OF SIX COMMERCIAL

©2011 AWS Truepower, LLC©2011 AWS Truepower, LLC

Thank you for your attention!