Perforated46
Perforted/DONN DX24
ClassificationASTM E 1264 classification, Type III, Form 2, Pattern C,E.
CompositionContains recycled material, no asbestos. Tile is a patented process blend of NC mineral fiber, inorganic fillers and specialty hydrophobic organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request.
Fire ReactionBS 476 Pt 6/7 Class 1/0ASTM E84, Class AFlame spread: 25Smoke developed: 15
Fire resistanceRegularBS 476 Pt 2330 min. protection to steel beams and timber floor.
Humidity ResistanceMaximum 90% RH / 32 °C
Thermal ResistanceR 0.33 m2 °C/W – R 1.4
Weight3.50 kg/m2 (Regular) for 15mm panel
MaintenanceEasily cleaned using soft brush or vacuum.
Perforated 47
Description• Accessible acoustical ceiling system with pin perforted panels.
Features and Benefits• Mid range sound absorption, provides balance to room acoustics• Mid range sound attenuation, ideal for general commercial construction• Maximum economy and design simplicity• Easy to trim and install
Applications• Education• Healthcare• Hotels • Leisure • Office• Retail
Perforated
Perforated
Perforated
*Type: R: Regular
SQ
SQ
SLT
R
R
R
84%
84%
84%
A, B1
A, B1
E
White
White
White
0.45 35 - 39
0.60 35 - 39
0.45 35 - 39
600 x 600 x 15 24’’ x 24’’ x 5/8’’
600 x 600 x 19 24’’ x 24’’ x 3/4’’
600 x 600 x 15 24’’ x 24’’ x 5/8’’
PS 665 PS 225 PS 669 PS 229 PSR 665 PSR 225
Hz 125 250 500 1000 2000 4000
Regular 15mm 0.35 0.40 0.40 0.55 0.55 0.55 αw = 0.5
Class D
αS
G
Plain48
Plain/DONN DX24
ClassificationASTM E 1264 classification, Type III, Form 2, Pattern C,E.
CompositionContains recycled material, no asbestos. Tile is a patented process blend of NC mineral fiber, inorganic fillers and specialty hydrophobic organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request.
Fire ReactionBS 476 Pt 6/7 Class 1/0ASTM E84, Class AFlame spread: 25Smoke developed: 15
Fire resistanceRegularBS 476 Pt 2330 min. protection to steel beams and timber floor.
Humidity ResistanceMaximum 90% RH / 32 °C (ClimaPlus)
Thermal ResistanceR 0.37 m2 °C/W – R 1.6
Weight3.50 kg/m2 (Regular / ClimaPlus 15mm)
MaintenanceEasily cleaned using soft brush or vacuum.
Plain 49
Description• Accessible acoustical ceiling system with plain finish panels
Features and Benefits• Low sound absorption, ideal where increased room reverberation is desired• Mid range sound attenuation, ideal for general commercial construction• High humidity resistant in ClimaPlus, suitable for applications with intermittent heating and cooling. May be installed early in the building program• Fire resistant system options, for life safety and protection of property• Easy to trim and install• High light reflectance performance
Applications• Education• Healthcare• Hotels • Leisure • Office• Retail
Plain
Plain
Plain
Plain
*Type: R: Regular
SQ
SLT
ILT
FL
R
R
R
R
85%
85%
85%
85%
A, B1
E
E
H, J
White
White
White
White
0.15 35 - 39
0.15 35 - 39
0.15 35 - 39
0.15 35 - 39
600 x 600 x 15 24’’ x 24’’ x 5/8’’
600 x 600 x 15 24’’ x 24’’ x 5/8’’
600 x 600 x 15 24’’ x 24’’ x 5/8’’
600 x 600 x 15 24’’ x 24’’ x 5/8’’
BS 665 BS 225 BSR 665 BSR 225 BSRI 665 BSRI 225 BSRF 665 BSRF 225
Hz 125 250 500 1000 2000 4000
0.35 0.25 0.10 0.15 0.20 0.45 αw = 0.15
Class E
αS
G
Sonatone White Sparta 50
Sonatone/DONN DX24
Plain White
Star Plus
ClassificationASTM E 1264 classification, Type XII, Form 1, Pattern E.
CompositionContains recycled material, no asbestos. Tile is a patented process blend of NC mineral fiber, inorganic fillers and specialty hydrophobic organic binders. Pre-finished with primer and PVC facing. Manufactured in water felted mineral fiber technology.Material safety data sheet available on request
Humidity ResistanceMaximum 95% RH / 32 °C
Thermal ResistanceR 0.37 m2 °C/W – R 2.2
Weight3.5 kg/m2 for 15mm panel, regular quality.
Maintenance:Easily cleaned using soft brush or vacuum, or a damp sponge.
Sonatone White Sparta 51
Description • Accessible acoustical ceiling system with smooth and textured laminated panels
Features and Benefits• Durable laminated construction• High light reflectance, to improve lighting efficiency. Lightweight for easy handling• Ultra high humidity resistant and sag resistance• Scrub resistant. Dirt marks are easy to remove.• Scuff and scratch resistant, for longer life• Easy to trim and install
Applications• Education• Healthcare / Laboratories• Hotels• Leisure• Office• Retail
Plain White
Plain White
Star Plus
Star Plus
*Type: R: Regular. Note: Other thicknesses available on request.
SQ
SQ
SQ
SQ
R
R
R
R
84%
84%
84%
84%
A, B1
A, B1
A, B1
A, B1
White
White
White
White
0.20 35
0.20 35
0.20 35
0.20 35
600 x 600 x 1524’’ x 24’’ x 5/8’’
600 x600 x 1924’’ x 24’’ x3/4‘‘
600 x 600 x 1524’’ x 24’’ x5/8‘‘
600 x 600 x 1924’’ x 24’’ x3/4‘‘
LPW 665LPW 225
LPW 669LPW 229
LSP 665LSP 225
LSP 669LSP 229
Hz 125 250 500 1000 2000 4000
0.30 0.25 0.15 0.15 0.25 0.35αS
G
Cross Fissured 52
Cross Fissured/DONN DX24
ClassificationASTM E 1264 classification, Type III, Form 2, Pattern C,D.
CompositionContains recycled material, no asbestos. Tile is a patented process blend of NC mineral fiber, inorganic fillers and specialty hydrophobic organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request.
Fire ReactionBS 476 Pt 6/7 Class 1/0 | ASTM E84, Class AFlame spread: 25 | Smoke developed: 10
Fire resistanceRegular | BS 476 Pt 2330 min. protection to steel beams and timber floor.FirecodeBS 476 Pt 21/23120 min. protection to steel beams and timber floor.
Humidity ResistanceMaximum 70% RH / 32°C (Regular)Maximum 90% RH / 32°C (ClimaPlus)
Thermal ResistanceR 0.33 m2 °C/W – R 1.4 (Regular / ClimaPlus )R 0.37 m2 °C/W – R 1.6 (Firecode)
Weight3.50 kg/m2(Regular / ClimaPlus 15mm), 5.00 kg/m2(Firecode 15mm) | 4.50 kg/m2 (Regular / ClimaPlus 19mm) | 6.10 kg/m2
(Firecode 19mm)
MaintenanceEasily cleaned using soft brush or vacuum.
Cross Fissured 53
Description• Accessible acoustical ceiling system with directional fissured panels
Features and Benefits• Maximum economy and design simplicity• Mid range sound absorption, provides balance to room acoustics• Mid range sound attenuation, ideal for general commercial construction• Easy to trim and install
Cross Fissured
Cross Fissured
Cross Fissured - Climaplus
Cross Fissured - Climaplus
Cross Fissured - Climaplus
Cross Fissured - Climaplus
Cross Fissured - Firechief
Cross Fissured - Firechief
*Type : R: Regular, CP: ClimaPlus, FC: Firecode.
SQ
SLT
SQ
SQ
SQ
SLT
SQ
SQ
R
R
CP
CP
CP
CP
FC
FC
82%
82%
82%
82%
82%
82%
82%
82%
A, B1
E
A, B1
A, B1
A, B1
E
A, B1
A, B1
White
White
White
White
White
White
White
White
0.50 35 - 39
0.50 35 - 39
0.50 35 - 39
0.50 35 - 39
0.60 35 - 39
0.60 35 - 39
0.50 35 - 39
0.60 35 - 39
600 x 600 x 1524’’ x 24’’ x 5/8’’
600 x 600 x 1524’’ x 24’’ x 5/8‘‘
600 x 600 x 1524’’ x 24’’ x5/8‘‘
600 x 1200 x 1524’’ x 48’’ x5/8‘‘
600 x 600 x 1924’’ x 24’’ x3/4‘‘
600 x 600 x 1924’’ x 24’’ x 3/4‘‘ 600 x 600 x 1524’’ x 24’’ x 5/8‘‘
600 x 600 x 1924’’ x 24’’ x 3/4‘‘
CFS 665CFS 225
CFSR 665CFSR 225
CFC 665CFC 225
CFC 625CFC 245
CFC 669CFC 229
CFCR 669CFCR 229
CFX 665CFX225
CFX 669CFX 229
Hz 125 250 500 1000 2000 4000
Regular 15 mm 0.30 0.35 0.35 0.45 0.55 0.70 αw= 0.45
Firecode 15 mm 0.30 0.30 0.30 0.40 0.55 0.65 αw= 0.4
Regular 19 mm 0.45 0.40 0.50 0.70 0.70 0.60 αw= 0.6
Class C for 19mmClass D for 15mm
αS
αS
αS
Applications• Education• Healthcare• Mass Merchandisers• Convenience Stores• Administrative Office• Retail / Corridors
G
Favia 54
Favia/DONN DX24
ClassificationASTM E 1264 classification, Type III, Form 2, Pattern C,D,E.
CompositionContains recycled material, no asbestos. Tile is a patented process blend of NC mineral fiber, inorganic fillers and specialty hydrophobic organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request.
Fire ReactionBS 476 Pt 6/7 Class 1/0ASTM E84, Class AFlame spread: 25Smoke developed: 15
Fire resistanceRegularBS 476 Pt 2330 min. protection to steel beams and timber floor.
Humidity ResistanceMaximum 90% RH / 32°C
Thermal ResistanceR 0.33 m2 °C/W – R 1.4
Weight3.50 kg/m2 (Regular 15mm)
MaintenanceEasily cleaned using soft brush or vacuum.
Favia 55
Description• Accessible acoustical ceiling system with fine non-directional fissured panel
Features and Benefits• Mid sound absorption, for effective reduction of unwanted noise• Mid range sound attenuation, ideal for general commercial construction• High humidity resistant in ClimaPlus, suitable for applications with intermittent heating and cooling. May be installed early in the building program• Fire resistant system options, for life safety and protection of property• Durable fully painted and sealed rebated edge options, ideal for frequently accessed ceilings• Easy to trim and install
Applications• Education• Healthcare• Hotels • Leisure • Administrative Office• Retail / Corridors• Mass Merchandisers• Stores
Favia
Favia
*Type: R: Regular**All items are available in 15mm(5/8’’) only.
SQ
SLT
R
R
85%
85%
A, B1
E
White
White
0.40 35 - 39
0.40 35 - 39
600 x 600 x 15 24’’ x 24’’ x 5/8’’
600 x 600 x 15 24’’ x 24’’ x 5/8’’
FNS 665 FNS 225
FNSR 665 FNSR 225
Hz 125 250 500 1000 2000 4000
Regular 0.30 0.35 0.35 0.45 0.55 0.70 αw = 0.4
Class D
αS
G
Favia Acoustic 56
Favia Acoustic/DONN DX24
ClassificationASTM E 1264 classification, Type III, Form 2, Pattern C,D,E.
CompositionContains recycled material, no asbestos. Tile is a patented process blend of NC mineral fiber, inorganic fillers and specialty hydrophobic organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request.
Fire ReactionBS 476 Pt 6/7 Class 1/0ASTM E84, Class AFlame spread: 25Smoke developed: 15
Fire resistanceRegularBS 476 Pt 2330 min. protection to steel beams and timber floor.
Humidity ResistanceMaximum 90% RH / 32°C
Thermal ResistanceR 0.37 m2 °C/W – R 1.7 for 19mmR 0.33 m2 °C/W – R 1.4 for 15mm
Weight3.50 kg/m2 (Regular / ClimaPlus 15mm)4.50 kg/m2 (Regular / ClimaPlus 19mm)
MaintenanceEasily cleaned using soft brush or vacuum.
Favia Acoustic 57
Description• Accessible acoustical ceiling system with fine non-directional fissured panel
Features and Benefits• Mid to high sound absorption, for effective reduction of unwanted noise• Mid range sound attenuation, ideal for general commercial construction• High humidity resistant in ClimaPlus, suitable for applications with intermittent heating and cooling. May be installed early in the building program• Fire resistant system options, for life safety and protection of property• Durable fully painted and sealed rebated edge options, ideal for frequently accessed ceilings•Easy to trim and install
Applications• Education• Healthcare• Hotels • Stores • Administrative Office• Retail / Mass Merchandisers
Favia Acoustic
Favia Acoustic
Favia Acoustic
Favia Acoustic- ClimaPlus
Favia Acoustic- ClimaPlus
Favia Acoustic- ClimaPlus
*Type: R: Regular, CP: ClimaPlus
SQ
SQ
SLT
SQ
ILT
ILT
R
R
R
CP
CP
CP
75%
75%
75 %
75 %
75 %
75 %
A, B1
A, B1
E
A, B1
B1, E
B1, E
White
White
White
White
White
White
0.50 35 - 39
0.60 35 - 39
0.50 35 - 39
0.60 35 - 39
0.50 35 - 39
0.60 35 - 39
600 x 600 x 15 24’’ x 24’’ x 5/8’’
600 x 600 x 19 24’’ x 24’’ x 3/4’’
600 x 600 x 15 24’’ x 24’’ x 5 / 8’’
600 x 600 x 19 24’’ x 24’’ x 3/4’’
600 x 600 x 15 24’’ x 24’’ x 5/8’’
600 x 600 x 19 24’’ x 24’’ x 3/4’’
FAS 665 FAS 225 FAS 669 FAS 229 FASR 665 FASR 225 FAC 669 FAC 229 FACRI 665 FACRI 225 FACRI 669 FACRI 229
Hz 125 250 500 1000 2000 4000
15mm 0.40 0.35 0.43 0.55 0.70 0.75 αw = 0.5
19mm 0.34 0.40 0.50 0.65 0.80 0.90 αw = 0.6
Class D for 15mmClass C for 19mm
αS
αS
G
Radar 58
Radar/DONN DX24
ClassificationASTM E 1264 classification, type III, Form 2, Pattern C, D, E
CompositionContains recycled material, no asbestos. Tile is a patented process blend of NC mineral fiber inorganic fillers and specialty hydrophobic organic binders. Pre-finished wih primer and top coat paints. Manufactured in water felted, mineral fiber technology. Material safety data sheet available on request.
Fire ReactionBS 476 pt 6/7 Class 1/0 | ASTM E84, Class AFlame spread: 25 | Smoke developed: 15
Fire ResistanceRegular | BS 476 Pt 2330 min. protection to steel beams and timber floor.FirecodeBS 476 Pt 21/23 | 120 min. protection to steel beams and timber floor.
Humidity ResistanceMaximum 90% RH / 32 °C
Thermal ResistanceR 0.37 m² °C/W - R 1.7 (Firecode 19mm-15mm) | R 0.33 m² °C/W -R 1.4 (Regular / ClimaPlus 15mm)
Weight3.50 kg/m2 (Regular/ClimaPlus) for 15mm panel | 5.00 kg/m2 (Firecode) for 15mm panel | 4.50 kg/m2 (Regular/ClimaPlus) for 19mm panel
Maintenance:Easily cleaned using soft brush or vacuum
Radar 59
Description• Accessible acoustical ceiling system with fine non-directional fissured panel
Features and Benefits• 360 ° non directional pattern with a fresh, clean appearance offers fast, economical installation• Mid range sound absorption, provides balance to room acoustics• Mid range sound attenuation, ideal for general commercial construction• Fire resistant system options, for life safety and protection of property• Easy to trim and install
Applications• Education• Healthcare• Hotels• Leisure• Office• Retail
αS
αS
αw = 0.5
αw = 0.6
G
RDX 625 RDX 245
FCFirechief 600 x 1200 x 1524"x 48"x 5/8"
600 x 600 x 1524"x 24"x 5/8"
600 x 600 x 1924"x 24"x 3/4"
600 x 600 x 1524"x 24"x 5/8"
600 x 1200 x 1524"x 48"x 5/8"
Rocktone 60
Rocktone/DONN DX15
ClassificationASTM E 1264 classification, type III, Form 2, Pattern C,D,E
CompositionContains recycled material, no asbestos. Tile is a patented process blend of NC mineral fiber inorganic fillers and specialty hydrophobic organic binders. Pre-finished wih primer and top coat paints. Manufactured in water felted, mineral fiber technology. Material safety data sheet available on request.
Fire ReactionBS 476 pt 6/7 Class 1/0ASTM E84, Class AFlame spread: 25Smoke developed:15
Fire ResistanceBS 476 Pt 2330 min.protection to steel beams and timber floor.
Humidity ResistanceMaximum 90% RH / 32 °C
Thermal ResistanceR 0.33 m² °C/W - 1.4 (Regular 15mm)
Weight3.50 kg/m2 (Regular) for 15mm panel
Maintenance:Easily cleaned using soft brush or vacuum
Rocktone 61
Description• Accessible acoustical ceiling system with fine non-directional fissured panels
Features and Benefits• 360° non directional pattern with a fresh, clean appearance offers fast, economical installation• Mid range sound absorption, provides balance to room acoustics• Mid range sound attenuation, ideal for general commercial construction• Fire resistant system options, for life safety and protection of property• Easy to trim and install
Applications• Education• Healthcare• Hotels• Leisure• Office• Retail
Rocktone
Type: R: Regular
SQ R 85% A, B1 White 0.50 35 - 39 600 x 600 x 15 24’’ x 24’’ x 5/8’’
RS 665 RS 225
Hz 125 250 500 1000 2000 4000
0.40 0.35 0.40 0.55 0.70 0.75 αS
G
Omni62
Omni/DONN DX15
ClassificationASTM E 1264 classification, Type III, Form 2, Pattern C,D.
CompositionContains recycled material, no asbestos. Tile is a patented process blend of NC mineral fiber, inorganic fillers and specialty hydrophobic organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request.
Fire ReactionBS 476 Pt 6/7 Class 1/0ASTM E84, Class AFlame spread: 25Smoke developed: 15
Fire ResistanceRegular | BS 476 Pt 23 | 30 min. protection to steel beams and timber floor.
FirecodeBS 476 Pt 21/23 | 120 min. protection to steel beams and timber floor.
Humidity ResistanceMaximum 90% RH / 32°C
Thermal ResistanceR 0.33 m2 °C/W – R 1.4 for (Regular / ClimaPlus 15mm)R 0.37 m2 °C/W – R 1.7 for (Firecode 19mm)
Weight3.50 kg/m2 (Regular / ClimaPlus 15mm)5.00 kg/m2 (Firecode 15mm)6.10 kg/m2 (Firecode 19mm)
MaintenanceEasily cleaned using soft brush or vacuum.
Omni 63
Description• Accessible acoustical ceiling system with fine non-directional fissured panels
Features and Benefits• 360° non directional pattern with a fresh, clean appearance offers fast, economical installation.• Mid range sound absorption, provides balance to room acoustics• Mid range sound attenuation, ideal for general commercial construction• Fire resistant system options, for life safety and protection of property• Easy to trim and install
Applications• Education• Healthcare• Hotels • Leisure • Office• Retail
Omni
Omni
Omni - Firechief
*Type: R: Regular, FC: Firecode.
SQ
SQ
SQ
R
R
FC
85%
85%
85%
A, B1
A, B1
A, B1
White
White
White
0.50 35 - 39
0.50 35 - 39
0.60 35 - 39
600 x 600 x 15 24’’ x 24’’ x 5/8’’
600 x 600 x 15 24’’ x 24’’ x 5/8’’
600 x 600 x 19 24’’ x 24’’ x 3/4’’
OMS 665 OMS 225 OMS 665W OMS 225W OMX 669 OMX 229
Hz 125 250 500 1000 2000 4000
Regular 15mm 0.40 0.35 0.43 0.55 0.70 0.75 αw = 0.5
Firecode 19mm 0.36 0.40 0.50 0.65 0.80 0.90 αw = 0.6
Class D for 15mmClass C for 19mm
αS
αS
Regular and Firecode panels are available in washable paint finish per ASTM D264
G
• Available in "WATER SHIELD" application.
Chessboard64
Chessboard/DONN DX24
ClassificationASTM E 1264 classification, Type III, Form 2, Pattern C,D,E,K.
CompositionContains recycled material, no asbestos. Tile is a patented process blend of NC mineral fiber, inorganic fillers and specialty hydrophobic organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request.
Fire ReactionBS 476 Pt 6/7 Class 1/0ASTM E84, Class AFlame spread: 25Smoke developed: 15
Fire resistanceClimaPlusBS 476 Pt 21/2330 min. protection to steel beams and timber floor.
Humidity ResistanceMaximum 90% RH / 32 °C
Thermal ResistanceR 0.37 m2 °C/W – R 1.7
Weight4.25 kg/m2 (Regular)
MaintenanceEasily cleaned using soft brush or vacuum.
Chessboard 65
Description• Accessible acoustical ceiling system with fine non-directional face cut panels
Features and Benefits• Shallow geometric square or linear face cuts disguise the grid for a monolithic appearance• Low sound absorption, ideal where increase room reverberation is desired• Mid range sound attenuation, ideal for general commercial construction• Easy to trim and install
Chessboard
*Type: R: Regular
SLT R 75% E White 0.15 35 - 39 600 x 600 x 19 24’’ x 24’’ x 3/4’’
CHSR 669 CHSR 229
Hz 125 250 500 1000 2000 4000
0.35 0.24 0.10 0.15 0.20 0.45 αw = 0.2
Class E
Applications• Education• Healthcare• Hotels• Leisure• Office• Retail
αS
G
Comet Line 66
Comet Line/ DONN DX24
ClassificationASTM E 1264 classification, Type III, Form 2, Pattern C,D,E,K.
CompositionContains recycled material, no asbestos. Tile is a patented process blend of NC mineral fiber, inorganic fillers and specialty hydrophobic organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request.
Fire ReactionBS 476 Pt 6/7 Class 1/0ASTM E84, Class AFlame spread: 25Smoke developed: 15
Fire resistanceRegularBS 476 Pt 2330 min. protection to steel beams and timber floor.Humidity ResistanceMaximum 90% RH / 32°C (ClimaPlus)
Thermal ResistanceR 0.37 m2 °C/W – R 1.7
Weight4.25 kg/m2 (Regular)
MaintenanceEasily cleaned using soft brush or vacuum.
Comet Line 67
Description• Accessible acoustical ceiling system with fine directional face cut panels
Features and Benefits• Shallow geometric square or linear face cuts disguise the grid for a monolithic appearance• Low sound absorption, ideal where increased room reverberation is desired• Mid range sound attenuation, ideal for general commercial construction• Easy to trim and install
Comet Line
*Type: R: Regular
SLT R 75% E White 0.15 35 - 39 600 x 600 x 19 24’’ x 24’’ x 3/4’’
CSR 669 CSR 229
Hz 125 250 500 1000 2000 4000
0.35 0.24 0.10 0.15 0.20 0.45 αw = 0.2
Class E
Applications• Education• Healthcare• Hotels• Leisure• Office• Retail
αS
G
Designer Squares 68
Designer Squares I/DONN DX15
ClassificationASTM E 1264 classification, Type III, Form 2, Pattern C,D,E,K.
CompositionContains recycled material, no asbestos. Tile is a patented process blend of NC mineral fiber, inorganic fillers and specialty hydrophobic organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request.
Fire ReactionBS 476 Pt 6/7 Class 1/0ASTM E84, Class AFlame spread: 25Smoke developed: 15
Fire resistanceRegularBS 476 Pt 2330 min. protection to steel beams and timber floor.
Humidity ResistanceMaximum 90% RH / 32°C
Thermal ResistanceR 0.33 m2 °C/W
Weight4.25 kg/m2 (Regular 19mm)
MaintenanceEasily cleaned using soft brush or vacuum.
Designer Squares 69
Description• Accessible acoustical ceiling system with fine non-directional fissured face cut panels
Features and Benefits• Deep geometric square or linear face cuts disguise the grid for a monolithic appearance• Mid - high sound absorption, for effective reduction of unwanted noise• Mid range sound attenuation, ideal for general commercial construction• High humidity resistant in ClimaPlus, suitable for applications with intermittent heating and cooling. May be installed early in the building program • Easy to trim and install
Designer Squares - Plain
Designer Squares -36 Plain
Designer Squares - 81 Plain
Designer Squares - Favia
Designer Squares - Perforated
*Type : R: Regular
SLT
SLT
FL
SLT
SLT
R
R
R
R
R
88%
88%
85%
83%
83%
E
E
H, J
E
E
White
White
White
White
White
0.15 35 - 39
0.15 35 - 39
0.15 35 - 39
0.60 35 - 39
0.60 35 - 39
600 x 600 x 1924’’ x 24’’ x 3/4’’
600 x 600 x 1924’’ x 24’’ x 3/4‘‘
600 x 600 x 1924’’ x 24’’ x 3/4‘‘
600 x 600 x 1924’’ x 24’’ x 3/4‘‘
600 x 600 x 1924’’ x 24’’ x 3/4‘‘
QBSR 669QBSR 229
QBSR 669 (36/15)QBSR 229 (36/15)
QBSRF 669 (81/5)QBSRF 229 (81/5)
QFNSR 669QFNSR 229
QPSR 669QPSR 229
Hz 125 250 500 1000 2000 4000
Plain 0.34 0.25 0.10 0.15 0.20 0.45 αw= 0.15
Perforted 0.35 0.40 0.50 0.65 0.80 0.90 αw= 0.6
Class C for PerfortedClass E for Plain
Applications• Education• Healthcare• Hotels • Leisure • Executive Office• Retail
αS
αS
G
Pedestals I70
Pedestals/DONN DX15
ClassificationASTM E 1264 classification, Type III, Form 1, Pattern E,L.
CompositionContains recycled material, no asbestos. Tile is a patented process blend of NC mineral fiber, inorganic fillers and specialty hydrophobic organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request.
Fire ReactionBS 476 Pt 6/7 Class 1/0ASTM E84, Class AFlame spread: 25Smoke developed: 15
Fire resistanceRegularBS 476 Pt 2330 min. protection to steel beams and timber floor.
Humidity ResistanceMaximum 90% RH / 32°C (ClimaPlus)
Thermal ResistanceR 0.37 m2 °C/W – R 1.7
Weight4.25 kg/m2 (Regular) for 3/4" panel
MaintenanceEasily cleaned using soft brush or vacuum.
Pedestals I 71
Description• Accessible acoustical ceiling system with plain textured stepped face cut panels
Features and Benefits• Triple stepped face cuts adds depth and proportion to the ceiling• Pedestals I, the look of 600 x 600 mm tiles• Contemporary non perforated plain texture• Mid range sound attenuation, ideal for general commercial construction• Easy to install and cut• Clean look for a rich looking ceiling
Applications• Education• Healthcare• Hotels• Leisure• Office
• Retail
Pedestal I Plain
*Type : R: Regular
ILT R 85% D White 0.15 35 - 39 600 x 600 x 19 24’’ x 24’’ x 3/4’’
DPIS669 DPIS229
Hz 125 250 500 1000 2000 4000
0.33 0.24 0.10 0.15 0.20 0.45 αw= 0.15
Class E
αS
G
USG specialty ceilings72
USG also offers a number of innovative specialty ceiling systems to enhance unique architectural settings. Whether you want a classic sculpted feel, the excitement and drama of a 3-dimensional design, or just plain elegance, USG can offer you ceiling solutions to meet the demanding and artistic requirements of contemporarybuilding interiors
DONN® grid suspension systems 73
USG is the world’s leading manufacturer of ceiling grid, offering the widest range of profiles on the market today. DONN® grid from USG is compatible with all USG ceiling tiles as well as most third party brands.
Innovation and quality you can build on
• DONN DX® from USG is the most widely specified grid in Middle East the patented clip design makes it fast and easy to install but also easy to remove without the need for tools.
• All USG DONN grid suspension systems are designed and manufactured to ensure both structural and aesthetic integrity in all ceiling designs. They are certified to meet the most stringent national standards and to comply with all relevant building codes and norms.
• Strict quality assurance procedures (ISO 9001 : 2008) ensure consistent manufacturing and finished product quality.
• USG’s extensive distribution and sales network has been operating for more than 25 years, supplying technical expertise and support to all our customers. You can rest assured that your products will be delivered wherever you need them, on spec and on time.
• From the product formulation we choose to the processes we employ, we are committed to products that are designed, manufactured, distributed and used in a sustainable way to minimize overall environmental impact.
Installing a DONN® grid system74
Step 1Measuring and planning are key first steps in the
installation process.
Measurement and placement of the tees will be on centre
(o.c.), meaning from the centre of one to the centre of
the next. Planning starts with a drawing of the room
that shows all walls, including bays, alcoves beams and
stairwells. Note which direction the joists (if any) are
running, or if architectural drawings necessitate working
in one direction or another. Determine the lines for main
runners and cross tees in such a way that the tiles that
about the wall are at least half a tile (300mm).
Step 2Mark the desired ceiling height (maintaining at
least 70mm clearance below the lowest duct, pipe
or beam.)
Measure and mark the walls at all corners above the
installation level (= add the height of the wall angle to
the desired ceiling height.) Snap a chalk line and test for
level. Measuring down from joists or up from the floor is
not recommended, since neither may be level. Install wall
angle with top edge of angle at the chalk line, spacing
appropriate fixings 450mm o.c. or closer. Cut and mitre
outside and inside angles at 45°, fitting them snugly
together. Alternatively, simply butt angles at corner (as in
system illustration).
➊ Main Tee 3600/3660mm ➋ Cross Tee 1200/1220mm ➌ Cross Tee 600/610mm ➍ Hanger
Steps 5/6
Step 2Step 4
➋ ➌
➍
➊
The appearance of a suspended acoustical ceiling is dependent both on the materials used and on the quality of the installation. USG manufactures com-ponents to meet BS8290 & BS EN 13964, assuring that the material, structural and quality standards are as prescribed. Installation must meet BS8290, assur-ing proper level and secure attachment as prescribed.Good construction condi-tions are very important when successfully installing a suspended ceiling. It is recommended that the temperature and humidity range be 14 – 25°C and max. 75% relative humidity. Store materials in a protected area, store tiles on the job at least 3 days prior to installation.
➊ Main tee
3600/3660mm
➋ Cross Tee
1200/1220mm
➌ Cross Tee
600/610mm
max. 450mm
x Hanger positions
75
Step 3To confirm level, stretch a string until taut along
the positions which the main tee will occupy.
Inserting a nail between the wall and the wall angle
at marked locations serves as a good anchor for this
purpose. Stretch another string across the room where the
first row of cross tees will be located. This identifies where
the first prepunched slots need to fall. Check to be sure
the cross tee string is at 90° to the main tee string via the
3-4-5 method. Install the hangers at 1200mm o.c. above
the lines of the main runners. Fix to the structure above
using appropriate plugs, screws or other devices.
Step 4Attach the main runners to the hangers.
In each row, trim the main tee so that the cross-tee slot
will line up with the cross-tee string. Mount main tees,
resting the cut end of the main tee on the wall angle. The
cut end of the main runner should be about 5mm away
from the wall.
Step 5Install cross tees, assuring that they are
adequately connected to main tees (they “click”
in place when properly seated).
Where two cross tees intersect in the same slot, insert
second cross-tee end to the left of the first. Where a
cross-tee is installed without an opposing cross-tee, a nail
should be slipped into the opening of the cross-tee clip to
maintain the pull-out value for the cross-tee.
Step 6Lay in panels, beginning at one corner and
completing row by row.
Tilt each panel up through the opening and lower it to
rest squarely on all four tees.
Step 7Removal as easy as installation.
Just grasp the main tee with one thumb under the main
tee-cross tee connection and, pushing up with the thumb,
give the main tee a quick, short twist. That’s all it takes –
no tools needed. The strong clip means that the grid can
be reinstalled straightaway with no tearing or bending of
the clip.
Step 8Main tee demounting
Using a straight shearing motion, push with your left hand
and pull with your right hand to disconnect the main
runner splice. Note: do not twist the splice during the
removal procedure
Other installation tips A Cut tees with aviation snips, first the stem and then the flanges.
B Cut mineral fibre panels with utility knife and straight edge, cutting the face first. Cut panels
should be at least 15mm larger than the opening.
C To install panels around obstructions, draw their exact locations on the panels and cut out. Then
cut the panel in two parts through the largest section of the cut-out to enable fitting.
D To trim for Shadowline edge, use a utility knife to cut the panel, first at the face, then from the
edge, to the same depth as Shadowline. If windows, stairwells, etc., extend above the ceiling plane,
build suitable valances and attach wall angle.
DONN® DX24 Intermidiate Duty 76
MaterialsAll USG suspension systems feature a body and cap made of hot-dip galvanized steel. To ensure that the cap remains attractive and rust-free for long term, manufacturing includes an exclusive four-step coating process that outperforms the competition in paint adhesion and corrosion resistance, as proven by industry-standard salt spray tests conducted by an independant laboratory.For our extreme environments we offer our grid system, with hot-dipped galvanized steel body and painted aluminum cap for additional corrosion and humidity resistance.
Product Information
Nr Description Item reference Metric Imperial
➊ Main Runner DX3600IM DX3660IM
➋ Long Cross Tee DX1200LM DX1220LM
➌ Short Cross Tee DX600LM DX610LM
➍ Wall Angle MT3600-MS3600
➎ Hanger DSW2
DX 24 / Suspension wire - DSW2
DX24 / Angle section - DGA5
QuantityLinear meter requierd per square meterFor construction layouts use the following formulas to calculate linear meters (LM) per square meter (m2)• Main tee(1/ Main Tee centres)eg. if MT at 1200mm centres — =0.83LM/m2
• Cross tee(1/ Cross Tee centres)eg. if CT at 600mm centres —– =1.67LM/m2
Note: These calculations do not allow for wastage,
damage or irregularities but are intended as an
informative guideline to assist with the calculation of
product required for a given area ( in m2)
System characteristics:• Exposed 24mm system• The most widely used grid system in the world• Safe, fast and simple to install & easily accessible• Maximum economy and design simplicity •Cross-tees with override-ends resist twisting and give professionnally finished look with no exposed steel edges• Patented QUICK-RELEASE TM clip design: demountable without tools• Compatible with square edge and SLB edge ceiling tiles• Audible Click means you know when tees are connected• Exceed load compliance specifications as per ASTM C 635• Available in metric and imperial sizes
1
1
1.2
0.60
Ref. Distance (mm)
A max. 1200
B 1200
C max. 400
D 600
77
Main Runner DX3600IM
Long Cross Tee DX1200LM
Short Cross Tee DX600LM
Module
Main runner at 1200mm Main runner at 600mm
Hanger distance (mm) 600 x 600 600 x 1200 600 x 600 600 x 1200
800 23.2 23.5 - -
1000 23.2 23.5 46.5 47.6
1200 11.6 11.6 23.2 23.4
1500 4.5 4.6 9.7 9.9
Note: The load per m2 must be distributed uniformly (no point loads) over the ceiling area. After loading, the deflection of any grid component will remain within the maximum deflection per span as stated in BS: 8290: 1991, provided the grid layout is as presented in the sketch.
Maximum allowed weight of tiles per m2 of ceiling
Please consult USG for other layouts, load or hanger distance.
Tile edge supported
Cross section
Clip to Clip Security
Main tee and cross tee connection.
Clip to Clip Connection
DX24 / SQDX24 / SLT
Specification DONN DX24-IMGrid shall be DONN DX24 exposed grid system, hot dipped galvanised steel ' T ' section with pre-painted capping. Table width 24mm. To suit variable module sizes, most typically 600 x 600mm and 1200 x 600mm.
Main runners: 33 x 24mm, ref DX3600IM shall be normally spaced at 1200mm centres and suspended from the structure or soffit using pre-straightened 2mm diameter HDG steel wire hang-ers, ref DSW2, at typically 1200mm centres. First hanger shall be no more than 450mm from the perimeter. Main runners joined end on by means of the integral splice. Splice connections shall be supported within 150mm with a hanger, and shall be staggered across the ceiling area.
Cross tees: 1200mm cross tees, 25 x 24mm ref DX1200LM, shall be installed perpendicular between the main runners at 600mm centres to form a 1200 x 600mm module. If applicable, 600mm cross tees, 25 x 24mm ref DX600LM, shall be installed perpendicular between the 1200mm cross tees to form a 600 x 600mm module. All cross tees feature a ‘joggled’ end detail.
Perimeter trims: 22mm x 19.5mm /19 x 9 x 9 x 19mm painted HDG steel angle trim, ref MT3600/MS3600, fixed to perimeter wall using fixings appropriate to the structure at maximum 450mm centres. Corners shall normally be finished with a lapped or butt joint.
Hangers: Shall be from pre straightened 2mm diameter HDG steel wire, ref DSW2. Hangers shall be fixed through holes in stalk or bulb of main runner and wrapped around itself a minimum of 3 times. Alternatively, hangers can be formed from 25 x 25mm HDG steel angle section, ref DGA5, fixed to main runners using appropriate self drilling screws or nut and bolt fixings. Hangers shall be normally spaced at 1200mm centres although alternative spacings are acceptable provided maximum loadings stated above are not exceeded. Hangers to be fixed to structure or sof-fit using fixings appropriate to the structure or soffit.
Hold down clips: Where applicable, these shall be non removable type clips, ref VB45. These generally will only be required in certain fire protecting assemblies or where there is a risk of tile uplift. Where fitted, these should be applied to all grid members at a rate of 1 clip per 600mm of tile edge.
DX24 / revoe clipPartition head fixing using revoe clips with DX24.
Spring clip 20248Spring clip application.
DX24 / SLB
DONN® DX24 Heavy Duty - Standard78
MaterialsAll USG suspension systems feature a body and cap made of hot-dip galvanized steel. To ensure that the cap remains attractive and rust-free for long term, manufacturing includes an exclusive four-step coating process that outperforms the competition in paint adhesion and corrosion resistance, as proven by industry-standard salt spray tests conducted by an independant laboratory.For our extreme environments we offer our grid system, with hot-dipped galvanized steel body and painted aluminum cap for additional corrosion and humidity resistance.
Product Information
Nr Description Item reference Metric Imperial
➊ Main Runner DX3600H DX3660H30
➋ Long Cross Tee DX1200H30 /
DX1200 LM
DX1220H30 /
DX 1220LM
➌ Short Cross Tee DX600H30 /
DX600LM
DX610H30 /
DX610LM
➍ Wall Angle MT3600-MS3600
➎ Hanger DSW2
DX24 / Suspension wire - DSW2
QuantityLinear meter requierd per square meterFor construction layouts use the following formulas to calculate linear meters (LM) per square meter (m2)• Main tee(1/ Main Tee centres)eg. if MT at 1200mm centres — =0.83LM/m2
• Cross tee(1/ Cross Tee centres)eg. if CT at 600mm centres —– =1.67LM/m2
Note: These calculations do not allow for wastage,
damage or irregularities but are intended as an
informative guideline to assist with the calculation of
product required for a given area ( in m2)
System characteristics:• Exposed 24mm system• The most widely used grid system in the world• Safe, fast and simple to install & easily accessible• Maximum economy and design simplicity •Cross-tees with override-ends resist twisting and give professionnally finished look with no exposed steel edges• Patented QUICK-RELEASE TM clip design: demountable without tools• Compatible with square edge and SLB edge ceiling tiles• Audible Click means you know when tees are connected• Exceed load compliance specifications as per ASTM C635• Available in metric and imperial size
1
1
1.2
0.60
Ref. Distance (mm)
A max. 1200
B 1200
C max. 400
D 600
DX24 / Angle section - DGA5
79
Main Runner DX3600H
Long Cross Tee DX1200H30 / DX1200LM
Short Cross Tee DX600H30 / DX 600LM
Module
Main runner at 1200mm Main runner at 600mm
Hanger distance (mm) 600 x 600 600 x 1200 600 x 600 600 x 1200
800 23.2 23.5 - -
1000 23.2 23.5 46.8 48.6
1200 12.3 12.4 24.6 25.2
1500 4.5 4.6 9.7 9.9
Note: The load per m2 must be distributed uniformly (no point loads) over the ceiling area. After loading, the deflection of any grid component will remain within the maximum deflection per span as stated in BS: 8290: 1991, provided the grid layout is as presented in the sketch.
Maximum allowed weight of tiles per m2 of ceiling
Please consult USG for other layouts, load or hanger distance.
Specification DONN DX24-HGrid shall be DONN DX24 exposed grid system, hot dipped galvanized steel ' T ' sec-tion with pre painted capping. Table width 24mm. To suit variable module sizes, most typically 600 x 600mm and 1200 x 600mm.
Main runners: 38 x 24mm, ref DX3600H shall be normally spaced at 1200mm centres and suspended from the structure or soffit using pre-straightened 2mm diameter HDG steel wire hang-ers, ref DSW2, at typically 1200mm centres. First hanger shall be no more than 450mm from the perimeter. Main runners joined end on by means of the integral splice. Splice connections shall be supported within 150mm with a hanger, and shall be staggered across the ceiling area.
Cross tees: 1200mm cross tees, 38 x 24mm ref DX 1200H30 and 25 x 24mm ref DX1200LM, shall be installed perpendicular between the main runners at 600 mm centres to form a 1200 x 600mm module. If applicable, 600mm cross tees, 25 x 24mm ref DX600LM and 38 x24mm ref DX600H30, shall be installed perpendicular between the 1200mm cross tees to form a 600 x 600mm module. All cross tees feature a ‘joggled’ end detail.
Perimeter trims: 22mm x 19.5mm/19 x 9 x 9 x19mm painted HDG steel angle trim, ref MT3600/MS3600, fixed to perimeter wall using fixings appropriate to the structure at maximum 450mm centres.Corners shall normally be finished with a lapped or but joint.
Hangers: Shall be from pre straightened 2mm diameter HDG steel wire, ref DSW2. Hangers shall be fixed through holes in stalk or bulb of main runner and wrapped around itself a minimum of 3 times. Alternatively, hangers can be formed from 25 x 25mm HDG steel angle section, ref DGA5, fixed to main runners using appropriate self drilling screws or nut and bolt fixings. Hangers shall be normally spaced at 1200mm centres although alternative spacings are acceptable provided maximum loadings stated above are not exceeded. Hangers to be fixed to structure or sof-fit using fixings appropriate to the structure or soffit.
Hold down clips: Where applicable, these shall be non removable type clips, ref VB45. These generally will only be required in certain fire protecting assemblies or where there is a risk of tile uplift. Where fitted, these should be applied to all grid members at a rate of 1 clip per 600mm of tile edge.
Tile edge supported
Cross section
Clip to Clip Security
Main tee and cross tee connection.
Clip to Clip Connection
DX24 / SQDX24 / SLT
DX24 / revoe clipPartition head fixing using revoe clips with DX24.
Spring clip 20248Spring clip application.
DX24 / SLB
DONN® DXL24 Heavy Duty - Fire Rated80
MaterialsAll USG suspension systems feature a body and cap made of hot-dip galvanized steel. To ensure that the cap remains attractive and rust-free for long term, manufacturing includes an exclusive four-step coating process that outperforms the competition in paint adhesion and corrosion resistance, as proven by industry-standard salt spray tests conducted by an independant laboratory.For our extreme environments we offer our grid system, with hot-dipped galvanized steel body and painted aluminum cap for additional corrosion and humidity resistance.
Product Information
Nr Description Item reference Metric Imperial
➊ Main Runner DXL3600 DXL3660
➋ Long Cross Tee DX1200H30 DX1220H30
➌ Short Cross Tee DX600H30 DX610H30
➍ Wall Angle MT3600 - MS3600
➎ Hanger DSW2
DX24 / Suspension wire - DSW2
DX24/ Angle section - DGA5
QuantityLinear meter requierd per square meterFor construction layouts use the following formulas to calculate linear meters (LM) per square meter (m2)• Main tee(1/ Main Tee centres)eg. if MT at 1200mm centres — =0.83LM/m2
• Cross tee(1/ Cross Tee centres)eg. if CT at 600mm centres —– =1.67LM/m2
Note: These calculations do not allow for wastage,
damage or irregularities but are intended as an
informative guideline to assist with the calculation of
product required for a given area ( in m2)
System characteristics:• Exposed 24mm system• The most widely used grid system in the world• Safe, fast and simple to install and easily accessible•Maximum economy and design simplicity• Cross-tees with override-ends resist twisting and give professionally finished look with no exposed steel edges•Patented QUICK-RELEASE TM clip design Demountable with tools• Compatible with Square edge and SLB edge ceiling tiles•Designed for fire rated ceilings• Audible Click means you know when tees are connected• Exceed load compliance specifications as per ASTM C 635• Available in metric and imperial sizes
1
1
1.2
0.60
Ref. Distance (mm)
A max. 1200
B 1200
C max. 400
D 600
81
Main Runner DXL3600
Long Cross Tee DX1200H30
Short Cross Tee DX600H30
Module
Main runner at 1200mm Main runner at 600mm
Hanger distance (mm) 600 x 600 600 x 1200 600 x 600 600 x 1200
800 23.7 23.9 - -
1000 23.7 23.9 55.9 56.3
1200 12.8 12.9 26.3 26.6
1500 4.6 4.8 10 10.3
Note: The load per m2 must be distributed uniformly (no point loads) over the ceiling area. After loading, the deflection of any grid component will remain within the maximum deflection per span as stated in BS: 8290: 1991, provided the grid layout is as presented in the sketch.
Maximum allowed weight of tiles per m2 of ceiling
Please consult USG for other layouts, load or hanger distance.
Tile edge supported
Cross section
Fire protection
Main tee and cross tee connection.
DX main tees are designed to expand at the fire lance in the event of a fire (shown here). This maintains the structural integrity of the ceiling and holds tiles in place.
DX24 / SQ DX24 / SLT
Specification DONN DXL24Grid shall be DONN DX24 exposed grid system, hot dipped galvanised steel ' T ' sec-tion with pre-painted capping. Table width 24mm. To suit variable module sizes, most typically 600 x 600mm and 1200 x 600mm.
Main runners: 38 x 24mm, ref DXL3600 shall be normally spaced at 1200mm centres and suspended from the structure or soffit using pre-straightened 2mm diameter HDG steel wire hang-ers, ref DSW2, at typically 1200mm centres. First hanger shall be no more than 450mm from the perimeter. Main runners joined end on by means of the integral splice. Splice connections shall be supported within 150mm with a hanger, and shall be staggered across the ceiling area.
Cross tees: 1200mm cross tees, 38 x 24mm ref DX1200H30, shall be installed perpendicular between the main runners at 600mm centres to form a 1200 x 600mm module. If applicable, 600mm cross tees, 38 x24mm ref DX600H30 shall be installed perpendicular between the 1200mm cross tees to form a 600 x 600mm module. All cross tees feature a ‘joggled’ end detail.
Perimeter trims: 22mm x 19.5mm/19 x 9 x9 x19mm painted HDG steel angle trim, ref MT3600/MS3600, fixed to perimeter wall using fixings appropriate to the structure at maximum 450mm centres. Corners shall normally be finished with a lapped or butt joint.
Hangers: Shall be from pre straightened 2mm diameter HDG steel wire, ref DSW2. Hangers shall be fixed through holes in stalk or bulb of main runner and wrapped around itself a minimum of 3 times. Alternatively, hangers can be formed from 25 x 25mm HDG steel angle section, ref DGA5, fixed to main runners using appropriate self drilling screws or nut and bolt fixings. Hangers shall be normally spaced at 1200mm centres although alternative spacings are acceptable provided maximum loadings stated above are not exceeded. Hangers to be fixed to structure or sof-fit using fixings appropriate to the structure or soffit.
Hold down clips: Where applicable, these shall be non removable type clips, ref VB45. These generally will only be required in certain fire protecting assemblies or where there is a risk of tile uplift. Where fitted, these should be applied to all grid members at a rate of 1 clip per 600mm of tile edge.
DX24 / revoe clipPartition head fixing using revoe clips with DX24.
Spring clip 20248Spring clip application.
DX24 / SLB
DONN® DX15 Centricitee82
MaterialsAll USG suspension systems feature a body and cap made of hot-dip galvanized steel. To ensure that the cap remains attractive and rust-free for long term, manufacturing includes an exclusive four-step coating process that outperforms the competition in paint adhesion and corrosion resistance, as proven by industry-standard salt spray tests conducted by an independant laboratory.For our extreme environments we offer our grid system, with hot-dipped galvanized steel body and painted aluminum cap for additional corrosion and humidity resistance.
Product Information
Nr Description Item reference Metric Imperial
➊ Main Runner DXT15-3600M DXT15-3660IM
➋ Long Cross Tee DXT15-1200M DXT15-1220IM
➌ Short Cross Tee DXT15-600M DXT15-610IM
➍ Wall Angle M93600
➎ Hanger DSW2
DX15 / Suspension wire - DSW2
DX15 / Angle section - DGA5
QuantityLinear meter requierd per square meterFor construction layouts use the following formulas to calculate linear meters (LM) per square meter (m2)• Main tee(1/ Main Tee centres)eg. if MT at 1200mm centres — =0.83LM/m2
• Cross tee(1/ Cross Tee centres)eg. if CT at 600mm centres —– =1.67LM/m2
Note: These calculations do not allow for wastage,
damage or irregularities but are intended as an
informative guideline to assist with the calculation of
product required for a given area ( in m2)
System characteristics:• Exposed 15mm system• Narrow table grid for subtle visual effect• Cross-tees with override-ends resist twisting and give professionally finished look with no exposed steel edges• Patented QUICK-RELEASE™ clip design: easy to remove without tools •Safe, fast and simple to install and easily accessible•Standard joggled (overriding) cross tee system• Suitable for FLB edge and most “face cut design” ceiling tiles• Designed for fire rated ceilings • Lay-on Cross Tees resist twist and gapping • Audible Click means you know when tees are connected• Exceed load compliance specifications as per ASTM C635• Available in metric in imperial size
1
1
1.2
0.60
Ref. Distance (mm)
A max. 1200
B 1200
C max. 400
D 600
83
Main Runner DXT15-3600M
Long Cross Tee DXT15-1200M
Short Cross Tee DXT15-600M
75mm 150mm 150mm 150mm
3600 mm
Module
Main runner at 1200mm Main runner at 600mm
Hanger distance (mm) 600 x 600 600 x 1200 600 x 600 600 x 1200
800 24.0 24.2 - -
1000 24.0 24.2 54.0 54.2
1200 12.4 12.5 25.5 25.7
1500 4.5 4.7 9.8 10.0
Note: The load per m2 must be distributed uniformly (no point loads) over the ceiling area. After loading, the deflection of any grid component will remain within the maximum deflection per span as stated in BS: 8290: 1991, provided the grid layout is as presented in the sketch.
Maximum allowed weight of tiles per m2 of ceiling
Please consult USG for other layouts, load or hanger distance.
Specification DONN DX15Grid shall be DONN DX15 exposed grid system, hot dipped galvanised steel ' T ' sec-tion with pre painted capping. Table width 15mm. To suit variable module sizes, most typically 600 x 600mm and 1200 x 600mm.
Main runners: 38 x 15mm, ref DXT15 - 3600M shall be normally spaced at 1200mm centres and suspended from the structure or soffit using pre-straightened 2mm diameter HDG steel wire hang-ers, ref DSW2, at typically 1200mm centres. First hanger shall be no more than 450mm from the perimeter. Main runners joined end on by means of the integral splice. Splice connections shall be supported within 150mm with a hanger, and shall be staggered across the ceiling area.
Cross tees: 1200mm cross tees, 38x15mm ref DXT15 - 1200M, shall be installed perpendicular between the main runners at 600mm centres to form a 1200 x 600mm module. If applicable, 600mm cross tees, 38x15mm ref DXT15-600M, shall be installed perpendicular between the 1200mm cross tees to form a 600 x 600mm module. All cross tees feature a ‘joggled’ end detail.
Perimeter trims: 24mmx15mm painted HDG steel angle trim, ref M9-3600, fixed to perimeter wall using fixings appropriate to the structure at maximum 450mm centres. Corners shall normally be finished with a lapped or butt joint.
Hangers: Shall be from pre straightened 2mm diameter HDG steel wire, ref DSW2. Hangers shall be fixed through holes in stalk or bulb of main runner and wrapped around itself a minimum of 3 times. Alternatively, hangers can be formed from 25 x 25mm HDG steel angle section, ref DGA5, fixed to main runners using appropriate self drilling screws or nut and bolt fixings. Hangers shall be normally spaced at 1200mm centres although alternative spacings are acceptable provided maximum loadings stated above are not exceeded. Hangers to be fixed to structure or sof-fit using fixings appropriate to the structure or soffit.
Hold down clips: Where applicable, these shall be non removable type clips, ref VB45. These generally will only be required in certain fire protecting assemblies or where there is a risk of tile uplift. Where fitted, these should be applied to all grid members at a rate of 1 clip per 600mm of tile edge.
Tile edge supported
Cross section (joggled)Main tee and cross tee connection.
Cross section (butt cut)Main tee and cross tee connection.
Fire protectionDX main tees are designed to expand at the fire lance in the event of a fire (shown here). This maintains the structural integrity of the ceiling and holds tiles in place.
DX15 / FL DX15 / FLB
USG Middle East Limited84
Uniform Loads - kg/lm (linear metre)ْUniform loads are loads that are transferred evenly along a given tee.The maximum load is the combined load on both sides of the tee.Example:A 1200 x 600 light fitting weighing 12.6 kg applies a load of 3.5 kg/lm(1.2 + 0.6 + 1.2 + 0.6 = 3.6 lmtherefore 12.6 kg / 3.6 lm = 3.5 kg/lm)A 1200 x 600 ceiling panel weighing 3.6 kg applies a load of 1 kg /lm The combined load of light and ceiling panel is 4.5 kg/lm.The maximum allowable uniform load is the lesser of either main or cross tee values.
Point Loads - kgPoint loads are loads that transfer to a tee at a single point (or several points) over a very small area. The weakest point is assumed to be mid span. main tees are based on a 1200mm span.The maximum allowable point load is the lesser of either main or cross tee values.
Loadings - DONN ® DX ® 24mm Exposed Grid
Ceiling Mass - Kg/m2
Use of Maximum Allowable Gross Ceiling Weight Charts:
• Determine the maximum allowable ceiling weight for the chosen Main Tee and hanger spacings from Graph.• Determine the maximum allowable ceiling weight for the chosen Cross Tee spacing from table.• The maximum allowable gross weight is the lower of the values from step 1 and 2.• Note that any heavy lighting, or other mechanical fixtures should be independentlysupported.• Siesmic considerations for in-plane loads may take precedence in determining the required section (refer USG Representative for detalis).
NOTES:•Values are based on simple span tests in accordance with recognised International Standard ASTM C635. Higher values can often be attained by allowing for the effect of continuous spans, the actual increase being subject to span arrangements. Please contact USG Interiors for guidance.• For cross-nogged configurations e.g.: where a 1200x600 mm panel runs parallel with the main tee, the spacing values should be used as for 1200x1200mm module.• Where main tees are at 1200mm centres, creating a 600x600mm configuration does not significantly increase load carrying limits.
DONN DX Component Uniform Load kg/lm
Main Tee
DX3600H (m)*
DX3600I (m)*
16.8
11.6
Cross Tee
DX600L (m)
DX1200L (m)
DX1200L (m)
35.4
16.7
5.9
* Hanger spacing @ 1.2m centres
DONN DX Component Point Load kg
Main Tee
DX3600H (m)*
DX3600I (m)*
7.9
7.0
Cross Tee
DX600L (m)
DX1200L (m)
DX1200L (m)
13.2
7.9
4.1
* Hanger spacing @ 1.2m centres
85
DONN® DX®
As worldwide leaders in acoustical ceiling systems, USG Interior works with the major lighting manufacturers to ensure system compatibility is maintained. The following guidlines are designed to assist in the correct specification and installation of light fittings in USG's DONN Exposed Grid and acoustical ceiling systems.
Luminaire Positioning Typical recessed pan fitting arrangements are shown below. Main Tees at 1200mm centres are shown horizontal, with suspension at 1200mm centres.• Refer to Loadings (page 64 this brochure) for maximum allowable point loads, uniform loads and gross ceiling loads depending on type of luminaire and DONN grid selected.Where luminaire weight exceeds point or uniform load maximums consider:a) A higher specifications DONN grid option if applicable (refer to Loadings page 64 this brochure to ensure compliance).b) Independent support from structure.c) Additional suspension points as shown below, or similar.
DONN Grid ProfilesWhen recessed pan fittings use the top of the DONN tee bulb for support, use the same height tee profiles for even support.
Ceiling panel Mounted FittingsLight fittings mounted through USG acoustical ceiling panels shall not rely on the ceiling panel for support. Their weight shall be transferred back to the grid by:
a) Simple supports across the back of the ceiling panel.
b) Simple supports onto the top of the tee bulb.
c) An additional rigid panel across the back of the ceiling panel.
Lighting Installation DONN® DX® 24mm Exposed Grid
Profile
DONN DX
Side Elevation End Elevation
NB: This method will affect the acoustic properties of the ceiling panel
Grid edge solutions86
DONN DX is the most widely specified grid in Middle East. It includes a wide range of
profiles and colours and is fully compatible with all USG ceiling tiles as well as most
third party brands. Precision design and quality manufacturing ensure both structural
and aesthetic integrity in all ceiling designs.
USG offers the following suspension system and
edge details options. Select a suspension system
and match it with a corresponding panel edge
details, or vice versa, to assure proper system fit
and assembly
1
1- MI/L Angle with SQ edge.2- L Angle-Standard angle (shown with site cut shadow edge tile).3- MS-Shadowline trim4- M/F Profile-for change of level and bulkheads5- L Angle - Standard angle fixed to timber batten.
3
5
4
2
Installation and maintenance 87
System performanceUSG ceiling systems should be installed in accordance with recommendations described within this
catalogue and the DONN grid application guide. System performance following any substitution of
materials or compromises in assembly cannot be guaranteed and may result in failure under critical
conditions. Reference should be made to BS 8290 1991 Suspended Ceilings parts 1, 2 and 3, and
the European Standard for Suspended Ceilings BS EN 13964:2004.
Site storage and handlingStorage on site should be as short as possible with environmental conditions as near as possible to
those specified for occupancy (see below). Any storage area should be secure and fully protected
from the weather with cartons stored on a clean, dry base. Cartons of material should never be
rolled, dropped or slid, and under no circumstances used as a workbase or substitute for ladders,
scaffolding, etc.
Pattern directionWith directional face patterns, such as Glacier and Sandrift, the orientation of pattern relative to
light sources should be carefully considered for desired visual effect, and specified and installed
accordingly. Variations in colour and fissure size in Glacier and Sandrift ceiling tiles will be of little
consequence within a single production batch. However, minor variations can occur from time to
time, and projects should be planned so that all material for continuous ceiling space is ordered and
delivered from the same production batch. Some USG tiles are marked with a directional arrow on
the back and should always be installed with this in alignment to ensure total consistency of pattern
and paint shade in a Production batch.
Overlaid materialWherever possible, overlaid material such as insulation, should not be laid directly on the back of
the ceiling membrane, as this will compromise the fire resistant properties of the ceilings. In normal
conditions (BS 8290), overlaid material should not exceed 3.6kg/m2 weight. For high humidity
environments, overlaid installation shall be limited to 1.2 kg/m2.
Installation/environmental conditionsFor applications with normal controlled environmental conditions, products with 70% RH/29°C
or better are suitable. Installation should only take place under ambient conditions after residual
moisture from concrete and plaster has dissipated.The recommended relative humidity should not
exceed 70% RH within a temperature range 65-85°F, 18-29°C for installation and occupancy.
Once ceiling installation has commenced, it is essential that RH% and temperature be maintained at
acceptable levels by heating the building if necessary. Dry heating should be employed and paraffin
or gas heaters avoided. These recommendations should still be applied between completion of
contract and the occupation of the building. Unoccupied buildings with uncontrolled atmospheres
may have a wide temperature range during a 24 hour period which could lead to an unacceptable
change in dimension stability of the ceiling panels, causing excessive sag.
For applications with intermittent heating and cooling systems, products with 90%RH/32°C or
better are recommended. (See Humidity selector, page 15.)For applications with uncontrolled
environmental conditions, natural ventilation systems or in humid areas such as washrooms, kitchens
or wet process areas, products with 95-99%RH/40°C or better are recommended. (See Humidity
selector, page 15.)Radar Ceramic and Sonatone ceiling panels perform especially well in areas such
as swimming pools, where the ceiling may be subject to unusually high levels of humidity up to
100% RH and chemical attack. They should be installed with USG DONN Corrosion Resistant ceiling
grid and appropriate hangers to resist corrosion.
All USG tiles should be protected from sustained direct contact with water except the treated one
as water shield.
Maintenance and cleaningGeneral cleaning of dust and loose dirt may be easily
achieved using a soft brush or vacuum cleaner. Soiled
panels can be cleaned with an art gum eraser or
dampened cloth or sponge containing as little water
as possible.
Clean Room tiles can be wet wiped on a regular basis
without damage.
Panels should never be soaked or immersed in water.
Cleaning can also be carried out by specialist
contractors using proprietary methods and
chemicals. It is strongly recommended that a trial
area be cleaned to ensure that there is no detrimental
effect on the ceiling panel or grid.
Re-decorationIt should be noted that a new paint finish may
compromise the Surface Spread of Flame classification
and acoustic absorption for that panel.
Please consult the USG Technical Services Department
for expert advice and recommendations.
Custom productsIn addition to a wide standard range, USG can
satisfy specifiers’ needs for non-standard, specialised
ceilings. Please talk to your local USG representative
to arrange production of your specific ideas.
Ceiling Systems Warranties and Limitations88
All USG DONN brand suspension systems, when used with any USG ceiling panels or tiles or
SHEETROCK brand gypsum lay-in ceiling panels, carry a lifetime (30-year) warranty that our products
shall be free from manufacturing defects and that the suspension systems shall be free from
the occurrence of 50% red rust as defined by ASTM D610 test procedures for 30 years from the
date of installation.
USG ceiling panels and tiles with CLIMAPLUS performance are specially formulated to endure
environments with up to 100% relative humidity and temperatures up to 104 F. these panels carry a
limited warranty against visible sag for 30 years when installed in a DONN suspension system.
Sag resistance is measured under 'Standard Test Method for strength Properties of Pre-fabricated
Architectural Acoustical Tile or Lay-in Ceiling Panels'.ASTM C367-05.
The Test Method cautions (Section 17.3) that it "is not designed to establish the expected
performance of the ceiling panels under field conditions of use, but only the sag properties for the
specific temperature, humidity, exposure time and mounting conditions used in the test.
Neither this test method nor any other laboratory test we are aware of can predict long-term sag
resistance. we do know that the higher the relative humidity and temperature, and the longer the
time these conditions prevail, the more susceptible to sag are the ceiling panels, Nevertheless, USG
has offered sag resistant ceiling panels for more than 20 years, and we have very rarely received
sag complaints. this excellent field performance is expected because the formulations of both core
and/or backing, depending on the particular panel, inherently impart sag resistance. Avoidance of
extreme temperature and humidity conditions are regular cleaning will enhance sag resistance and
all other performance attributes of the ceiling panels.
USG CKIMAPLUS ceiling panels with superior performance are warranted to be free from the
growth of mold, mildew, and Gram-negative odor- and stain-causing bacteria for 30 years from the
date of installation. these ceiling panels include an antimicrobial treatment on the painted surface
that contains a mold-inhabiting agent that provides broad-spectrum control for the growth of mold
and mildew over the warranty period; these ceiling panels also resist the growth of Gram-psitive
and Gram-negative odor and stain causing bacteria.
CLIMAPLUS fiberglass and RADAR Ceramic CLIMAPLUS ceiling panels do not have Superior
performance antimicrobial treatment;they are warranted to be free from the growth of mold,
mildew, and odor-and stain- causing bacteria for 30 years from the date of installation due to the
inherent characteristics of the products.
CLEAN ROOM CLIMAPLUS and SHEETROCK CLIMAPLUS gypsum lay-in panels do not feature
the Superior performance antimicrobial treatment and therefore are not included in the 30-Year
Antimicrobial System warranty.
All USG limited warranties are subject to use under normal conditions. abnormal conditions include
exposure to chemical fumes, vibration, moisture from conditions such as leaks or condensation,
excessive humidity, or excessive dirt or dust buildup.
By "lifetime" we mean the useful life of the ceiling system, up to a maximum of 30 years.
Lifetime (30-Year) Limited Warranty
89
The CLIMAPLUS warranty periods for these and other USG products and systems are as follows:
All warranties are subject to the following terms and conditions:
Exept where stated otherwise on specific product warranties, all USG warranties cover original
owner of the building at the time of installation.
In the unlikely event of product performance failure, at our election USG will replace the goods
or we will refund or credit an amount equal to the (original) purchase price of the goods within
warranted conditions.
The building owner is responsible for all costs associated with removal and installation.
All ceiling products and system must be installed and maintained in accordance with current USG
written instructions and best industry practice, including the CISCA Handbook and ASTM C636.
"Standard Practice for Installation of Metal ceiling suspension system for Acoustical tile and lay-in
panels. "SHEETROCK Gypsum panels used with USG Drywall suspension system are not covered.
Also, you must observe the following:
-Care must be taken that the products are not damaged during delivery and while they are stored
at the job site.
-The products must always be protected from vibration, direct contact with water including
condensation, and chemical fumes, both before and after installation.
-These products may not be used in exterior applications, The only exception is RADAR Ceramic
CLIMAPLUS, which may be used in exterior soffits.
Except for ceiling with superior performance, CLIMAPLUS fiberglass ceiling panels and RADAR
Ceramic CLIMAPLUS ceiling panels, the growth of mold or bacteria is not covered by this warranty
nor it is the responsibility of USG. All products should be maintained to avoid excessive dirt or dust
buildup or the presence of excessive moisture that would provide a medium for microbial growth on
ceiling panels.
Damage that may occur from vibration,fire, water, freezing temperature, accident, any form of abuse
or exposure to abnormal conditions is no covered in this warranty.
If subject to abnormal conditions, the products should be removed immediately and replaced once
the conditions are normal.
Warranties
Who is covered?
What will USG do?
What does this warranty not cover?
Ceiling Systems
ClimaPlus Panels & Tile plus DONN Suspension System
All other USG Ceiling Panels & Tile plus DONN Suspension System
USG Specialty Ceiling
Panel/Tile Suspension System
Lifetime 30 Years Lifetime 30 Years
1 Years Lifetime 30 Years
1 Years ____
Individual Products
ClimaPlus Panels & Tile
All other USG Ceiling Panels & Tile
DONN Suspension Systems
Panel/Tile Suspension System
10 Years __
1 Years __
____ 10 Years
Ceiling Systems Warranties and Limitations90
Warranty Conditions
Suspension Systems
General notes
Performance Level
Radar Ceramic CLIMAPLUS
CLIMAPLUS Ceiling
Standard Commercial Ceilings
All ceiling products and suspension systems must be installed and maintained in accordance with
USG written installation instructions for that product in effect at the time of installation and best
industry practice. Prior to, during, and after installation, the ceiling product must be kept clean and
dry, and maintained in an environment free of chemical fumes or vibration, not subject to abnormal
conditions and within the following conditions:
for RADAR Ceramic CLIMAPLUS ceiling panels: the sag performance warranty extends
toinstallations where the ceiling product is exposed to environments subjest to temperatures of
60-104° F (16-40° C), chemical fumes, steam, and up to 100% RH, including standing water
applications, so long as the product is installed with either AX or ZXLA suspension systems. For
swimming pools, install only with AX or ZXLA suspension systems. For outdoor soffits, canopies and
parking garages, install with ZXLA suspension system (wind uplift should be considered).
For all CLIMAPLUS products (excludes CLEAN ROOM CLIMAPLUS and SHEETROCK gypsum lay-in
panels): these ceilings must be maintained to avoid excessive dirt or dust buildup that would provide
a medium for microbial growth on these panels or tiles. Microbial protection does not extend beyond
the treated surface as received from the factory, and does not protect other materials that contact
the treated surface such as supported materials.
Prior to, during, and after installation, the suspension systems (excluding DXLA, AX, ZXLA and the
USG drywall suspension system) shall be maintained in a temperature range of 60-104° F (16-40°C)
and relative humidity shall not exceed 90%. DXLA shall be maintained in a temperature range of
60-104° F (16-40°C) and relative humidity shall not exceed 95%. AX, ZXLA and the USG Drywall
suspension system shall be maintained in a temperature range from 60-104° F (16-40°C) and
relative humidity can be up to 100%.
The warranty does not cover rusting that occurs from building leaks or condensation.
The ceiling panels must not be used to support any materials including insulation. Where insulation
must be used, it should be on heavier than 1.27kg/m2 and installed with the following USG
recommendations: insulation must be applied perpendicular to the suspension cross tees with the
suspension system supporting the weight of the insulation. insulation is also not recommended
to be used as follows: Firecode applications, unless specified and use described by underwriters
laboratories, Inc. Mold or mildew growth on insulation or placed above the ceiling panel or tile are
not covered by this warranty.
This warranty does not cover damage caused by fire, water, accident, or by any form of abuse except
normal wear and tear.
Please see USG written instructions about proper maintenance, touch up, and repainting of our
ceiling system. Please note that not all products can be repainted and that repainting will affect
acoustical performance, appearance, microbial resistance, fire resistance, and ventilation through the
ceiling panels or tiles.
Environmental Limitations
60-104° F (16-40° C) Up to 100 % RH
60-104° F (16-40° C) Up to 95 % RH
60-85° F (16-29° C) Up to 70 % RH
1- RADAR Ceramic ceiling panels with CLIMAPLUS
performance will withstand corrosive chemical
fumes and contain coatings and/or formulation to
inhibit or retard the growth of mold and mildew.
91
Normal environmental conditions must prevail to warrant product performance. This warranty will
not cover situations where the panels are subject to vibrations or chemical fumes or where moisture
comes in contact with the ceiling panel or tile as a result of a leaking roof, a sweating pipe, a
leaking radiator, a flood, condensation on windows, condensation on more subtle surfaces where
dew points are reached, humidified air from the HVAC system or any other similar causes.
You must notify USG-ME sales representative of the problem within 30 days of the time the
problem first became apparent to you. Please send us any photographs of the problem area as
these are often helpful. We will contact you within 30 days and, if we authorize a replacement or
payment, this will be done within 30 days thereafter.
This warranty gives you specific legal rights and you may also have other rights, which vary from
country to country.
Replacement or refunding the purchase price of defective material shall constitute the sole and
total obligations of USG. We shall not be responsible for any labor charges or other installation or
replacement costs or for incidental or consequential damages of any nature whatsoever.
THIS WARRANTY IS IN LIEU OF AND EXCLuDES ALL OTHER WARRANTIES NOT EXPRESSLY SET
FORTH HEREIN, WHETHER IMPLIED BY OPERATION OF LAW OR OTHERWISE, INCLUDING, BUT NOT
LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS.
How do you get service?
How does state lay apply?
Manufactured by USG-ME, Dammam, KSA
WIWL, Rev.o@2011, USG-ME LTD, Printed in Bahrain
The following trademarks used herein are owned by USG Corporation or a related company: ASTRO, CLEAN ROOM, CLIMAPLUS, DONN, ECLIPSE, FROST, HALCYON, MARS, MILLENNIA, OLYMPIA MICRO, SONATA, PEBBLED, RADAR, ROCK FACE, SANDRIFT, SHEETROCK, SUMMIT, TOUCHSTONE.
www.usg-me.com
USG reserves the right to change specifications or design and supply products which may differ from those described and illustrated without notice and without liability. All weights and measures are nominal.
DONN® is a trademark of USG Interiors Inc. or affiliated companies.
© 2011
DC/03/ME/01/11
USG Middle East Ltd.
Dammam, Saudi ArabiaTel: +966 3 812 0995Fax: +966 3 812 1029e-mail: [email protected]
Jeddah, Saudi ArabiaTel: +966 2 639 2172 +966 2 691 0251Fax: +966 2 682 3711e-mail: [email protected]
Riyadh, Saudi ArabiaTel: +966 1 291 8351 +966 1 291 8923Fax: +966 1 291 8894e-mail: [email protected]
Dubai, U.A.E.Tel: +971 4 295 4443Fax: +971 4 295 4566e-mail: [email protected]
Manama, BahrainTel: +973 17 581 596Fax: +973 17 581 [email protected]
Beirut, LebanonTel: +961 1 360 888 +961 1 365 309Fax: +961 1 365 280 +961 1 361 461e-mail: [email protected]
Doha, QatarTel: +974 44 231 146Fax: +974 44 231 [email protected]