32
BSC6000 Parameter Name Parameter Name Script Located 1 Allow Dynamic Voltage Adjustment 2 Allow Dynamic Shutdown of TRX Power Amplifier 3 TCH/H Use Downlink DTX 4 MAX TA(bit period(1 bit=0.55km)) MAXTA SET GCELLBASICPARA 5 TCH/F Use Downlink DTX 6 Encryption Algorithm ENCRY SET GCELLBASICPARA 7 DL PC Allowed DNPCEN SET GCELLBASICPARA 8 UL PC Allowed UPPCEN SET GCELLBASICPARA 9 Directed Retry DIRECTRYEN SET GCELLBASICPARA 10 TCH Immediate Assignment IMMASSEN SET GCELLBASICPARA 11 TCH/H Uplink DTX 12 RXLEV_ACCESS_MIN RXMIN SET GCELLBASICPARA 13 Call Reestablishment Forbidden CALLRESTABDIS SET GCELLBASICPARA 14 TCH/F Uplink DTX 15 PT(s) PT SET GCELLIDLEAD 16 TO TO SET GCELLIDLEAD 17 Additional Reselect Param Indication ACS SET GCELLIDLEAD 18 CRO(2dB) CRO SET GCELLIDLEBASIC 19 Cell_Bar_Qualify CBQ SET GCELLIDLEBASIC 20 PI PI SET GCELLIDLEBASIC 21 CRH(dB) CRH SET GCELLIDLEBASIC 22 Period of Periodic Location Update(6 minutes) T3212 SET GCELLIDLEBASIC 23 BS-PA-MFRAMS BSPAMFRAMS SET GCELLIDLEBASIC 24 BS_AG_BLKS_RES BSAGBLKSRES SET GCELLIDLEBASIC 25 NCC Permitted NCCPERMITED SET GCELLEXTMSRPARA 26 Cell_Bar_Access CBA SET GCELLIDLEBASIC 27 Tx-integer TX SET GCELLIDLEBASIC 28 Attach/Detach Allowed ATT SET GCELLIDLEBASIC 29 Threshold Adjust Factor 30 Long-term FER Target 31 Long-term FER Lower Threshold 32 Long-term FER Upper Threshold 33 AMR Uplink Adaptive Threshold Allowed 34 AMR TFO Switch 35 AMR Starting Mode(H) INITCDMDH SET GCELLCCAMR 36 AMR DL Coding Rate adj.hyst3(H) DLHYSTH3 SET GCELLCCAMR 37 AMR DL Coding Rate adj.hyst2(H) DLHYSTH2 SET GCELLCCAMR 38 AMR DL Coding Rate adj.hyst1(H) DLHYSTH1 SET GCELLCCAMR 39 AMR DL Coding Rate adj.th3(H) DLTHH3 SET GCELLCCAMR 40 AMR DL Coding Rate adj.th2(H) DLTHH2 SET GCELLCCAMR 41 AMR DL Coding Rate adj.th1(H) DLTHH1 SET GCELLCCAMR 42 AMR UL Coding Rate adj.hyst3(H) ULHYSTH3 SET GCELLCCAMR Basic Attributes Idle Mode BSC6900 No Group

201081469 Huawei NSN Siemens Parameter

Embed Size (px)

Citation preview

Page 1: 201081469 Huawei NSN Siemens Parameter

BSC6000

Parameter Name Parameter Name Script Located1 Allow Dynamic Voltage Adjustment

2 Allow Dynamic Shutdown of TRX Power Amplifier

3 TCH/H Use Downlink DTX

4 MAX TA(bit period(1 bit=0.55km)) MAXTA SET GCELLBASICPARA

5 TCH/F Use Downlink DTX

6 Encryption Algorithm ENCRY SET GCELLBASICPARA

7 DL PC Allowed DNPCEN SET GCELLBASICPARA

8 UL PC Allowed UPPCEN SET GCELLBASICPARA

9 Directed Retry DIRECTRYEN SET GCELLBASICPARA

10 TCH Immediate Assignment IMMASSEN SET GCELLBASICPARA

11 TCH/H Uplink DTX

12 RXLEV_ACCESS_MIN RXMIN SET GCELLBASICPARA

13 Call Reestablishment Forbidden CALLRESTABDIS SET GCELLBASICPARA

14 TCH/F Uplink DTX

15 PT(s) PT SET GCELLIDLEAD

16 TO TO SET GCELLIDLEAD

17 Additional Reselect Param Indication ACS SET GCELLIDLEAD

18 CRO(2dB) CRO SET GCELLIDLEBASIC

19 Cell_Bar_Qualify CBQ SET GCELLIDLEBASIC

20 PI PI SET GCELLIDLEBASIC

21 CRH(dB) CRH SET GCELLIDLEBASIC

22 Period of Periodic Location Update(6 minutes) T3212 SET GCELLIDLEBASIC

23 BS-PA-MFRAMS BSPAMFRAMS SET GCELLIDLEBASIC

24 BS_AG_BLKS_RES BSAGBLKSRES SET GCELLIDLEBASIC

25 NCC Permitted NCCPERMITED SET GCELLEXTMSRPARA

26 Cell_Bar_Access CBA SET GCELLIDLEBASIC

27 Tx-integer TX SET GCELLIDLEBASIC

28 Attach/Detach Allowed ATT SET GCELLIDLEBASIC

29 Threshold Adjust Factor

30 Long-term FER Target

31 Long-term FER Lower Threshold

32 Long-term FER Upper Threshold

33 AMR Uplink Adaptive Threshold Allowed

34 AMR TFO Switch

35 AMR Starting Mode(H) INITCDMDH SET GCELLCCAMR

36 AMR DL Coding Rate adj.hyst3(H) DLHYSTH3 SET GCELLCCAMR

37 AMR DL Coding Rate adj.hyst2(H) DLHYSTH2 SET GCELLCCAMR

38 AMR DL Coding Rate adj.hyst1(H) DLHYSTH1 SET GCELLCCAMR

39 AMR DL Coding Rate adj.th3(H) DLTHH3 SET GCELLCCAMR

40 AMR DL Coding Rate adj.th2(H) DLTHH2 SET GCELLCCAMR

41 AMR DL Coding Rate adj.th1(H) DLTHH1 SET GCELLCCAMR

42 AMR UL Coding Rate adj.hyst3(H) ULHYSTH3 SET GCELLCCAMR

Basic

Att

rib

ute

sId

le M

od

eC

all

Co

ntr

ol

BSC6900No Group

Page 2: 201081469 Huawei NSN Siemens Parameter

43 AMR UL Coding Rate adj.hyst2(H) ULHYSTH2 SET GCELLCCAMR

44 AMR UL Coding Rate adj.hyst1(H) ULHYSTH1 SET GCELLCCAMR

45 AMR UL Coding Rate adj.th3(H) ULTHH3 SET GCELLCCAMR

46 AMR UL Coding Rate adj.th2(H) ULTHH2 SET GCELLCCAMR

47 AMR UL Coding Rate adj.th1(H) ULTHH1 SET GCELLCCAMR

48 AMR ACS(H)(Kbit/s) ACTCDSETH SET GCELLCCAMR

49 AMR Starting Mode(F) INITCDMDF SET GCELLCCAMR

50 AMR DL Coding Rate adj.hyst3(F) DLHYSTF3 SET GCELLCCAMR

51 AMR DL Coding Rate adj.hyst2(F) DLHYSTF2 SET GCELLCCAMR

52 AMR DL Coding Rate adj.hyst1(F) DLHYSTF1 SET GCELLCCAMR

53 AMR DL Coding Rate adj.th3(F) DLTHF3 SET GCELLCCAMR

54 AMR DL Coding Rate adj.th2(F) DLTHF2 SET GCELLCCAMR

55 AMR DL Coding Rate adj.th1(F) DLTHF1 SET GCELLCCAMR

56 AMR UL Coding Rate adj.hyst3(F) ULHYSTF3 SET GCELLCCAMR

57 AMR UL Coding Rate adj.hyst2(F) ULHYSTF2 SET GCELLCCAMR

58 AMR UL Coding Rate adj.hyst1(F) ULHYSTF1 SET GCELLCCAMR

59 AMR UL Coding Rate adj.th3(F) ULTHF3 SET GCELLCCAMR

60 AMR UL Coding Rate adj.th2(F) ULTHF2 SET GCELLCCAMR

61 AMR UL Coding Rate adj.th1(F) ULTHF1 SET GCELLCCAMR

62 AMR ACS(F)(Kbit/s) ACTCDSETF SET GCELLCCAMR

63 EMC Priority Level

64 Emergency Call Preemption Permitted

65 Max Assignment Retry Times

66 Frequency Band of Reassign

67 Short Message Downlink Disabled

68 Short Message Uplink Disabled

69 Immediate Assignment Opt.

70 Repeated SACCH

71 Repeated Downlink FACCH Threshold

72 Repeated Downlink FACCH

73 Abis Resource Adjustment TCHH Function Switch

74 Allow EMLPP

75 Allow Reassign

76 TDD MI System Information Broadcasting Prohibit

77 TDD System Information Optimized Allowed

78 TDD Cell Threshold TDDCELLTHRED SET GCELLCCUTRANSYS

79 TDD Cell offset TDDCELLOFF SET GCELLCCUTRANSYS

80 Best TDD Cell Number

81 TDD Cell Reselect Diversity(dB) TDDCELLRESELDIV SET GCELLCCUTRANSYS

82 FDD Reporting Threshold FDDCELLTHRED SET GCELLCCUTRANSYS

83 FDD Reporting Offset FDDCELLOFF SET GCELLCCUTRANSYS

84 1800M Reporting Threshold

85 1800M Reporting Offset

86 900M Reporting Threshold

87 900M Reporting Offset

88 Qsearch C QSEARCHC SET GCELLCCUTRANSYS

Ca

ll C

on

tro

l

Page 3: 201081469 Huawei NSN Siemens Parameter

89 Scale Order

90 Invalid BSIC Reporting

91 3G Search PRIO

92 Qsearch P QP SET GCELLCCUTRANSYS

93 FDD Qmin FDDQMIN SET GCELLCCUTRANSYS

94 FDD MULTIRAT Reporting FDDFREQCNUM SET GCELLCCUTRANSYS

95 FDD REP QUANT FDDREP SET GCELLCCUTRANSYS

96 FDD Q Offset FDDQOFF SET GCELLCCUTRANSYS

97 Qsearch C Initial QCI SET GCELLCCUTRANSYS

98 Qsearch I QI SET GCELLCCUTRANSYS

99 Serving Band Reporting

100 Power Deviation(2dB) PWRDIV SET GCELLCCACCESS

101 Power Deviation Indication

102 MBR MBR SET GCELLCCBASIC

103 ECSC ECSC SET GCELLCCBASIC

104 Radio Link Timeout(SACCH period (480ms)) RLT SET GCELLCCBASIC

105 Emergent Call Disable ERGCALLDIS SET GCELLCCBASIC

106 Special Access Control Class

107 Common Access Control Class COMMACC SET GCELLCCBASIC

108 MS MAX Retrans(Time) MSMAXRETRAN SET GCELLCCBASIC

109 Max Transmit Times of Imm_Ass

110 Max Delay of Imm_Ass Retransmit(ms)

111 Use Imm_Ass Retransmit Parameter

112 N200 of FACCH/Full rate N200FFULL SET GCELLCCTMR

113 N200 of FACCH/Half rate N200FHALF SET GCELLCCTMR

114 N200 of SDCCH N200SDCCH SET GCELLCCTMR

115 N200 of SACCH N200SACCH SET GCELLCCTMR

116 N200 of Release

117 N200 of Establish

118 Use LAPDm N200

119 T200 SDCCH SAPI3(5ms) T200SDCCH3 SET GCELLCCTMR

120 T200 SACCH SDCCH(10ms) T200SACCHS SET GCELLCCTMR

121 T200 SACCH TCH SAPI3(10ms) T200SACCH3 SET GCELLCCTMR

122 T200 SACCH TCH SAPI0(10ms) T200SACCT0 SET GCELLCCTMR

123 T200 FACCH/H(5ms) T200FACCHH SET GCELLCCTMR

124 T200 FACCH/F(5ms) T200FACCHF SET GCELLCCTMR

125 T200 SDCCH(5ms) T200SDCCH SET GCELLCCTMR

126 RACH Min.Access Level(dbm) RACHACCLEV SET GCELLCCACCESS

127 Random Access Error Threshold

128 TRX Aiding Function Control

129 Speech Version SPEECHVERSION SET BTSCHNFALLBACK

130 AHR Radio Link Timeout(SACCH period (480ms)) AHRDSBLCNT SET GCELLCCBASIC

131 AFR Radio Link Timeout(SACCH period (480ms)) AFRDSBLCNT SET GCELLCCBASIC

132 AHR SACCH Multi-Frames(SACCH period (480ms)) AHRSAMULFRM SET GCELLCCBASIC

133 AFR SACCH Multi-Frames(SACCH period (480ms)) AFRSAMULFRM SET GCELLCCBASIC

134 Directed Retry Load Access Threshold

Ca

ll C

on

tro

l

Page 4: 201081469 Huawei NSN Siemens Parameter

135 Assignment Cell Load Judge Enable

136 Paging Times

137 RACH Busy Threshold

138 SACCH Multi-Frames(SACCH period (480ms)) SAMULFRM SET GCELLCCBASIC

139 IBCA Init. Power Control Rx Qual UL Offset

140 IBCA Init. Power Control Rx Qual DL Offset

141 IBCA Init. Power Control RexLevUL Offset

142 IBCA Init. Power Control RexLevDL Offset

143 Handover to Overlayer RxLev Offset(dB)

144 Assign to Overlayer RxLev Offset(dB)

145 Low Rxlev Overlayer Forbid Allocation Switch

146 IBCA Path Lose Filter Factor

147 IBCA ICDM Switch

148 IBCA Wait SDCCH Idle Timer(s)

149 IBCA Tight Trx SDCCH Rxlev Thredhold(dB)

150 IBCA Loose Trx SDCCH Load Thredhold(%)

151 C/I Estimate Value(dB)

152 Non-AMR User Allocate Loose Frequency Reuse Mode Trx Preference

153 IBCA Call Information Filter Length

154 IBCA Dynamic Measure Neighbor Cell Allowed

155 IBCA Waiting Measurement Report Time(0.5s)

156 IBCA Pathloss Offset

157 IBCA Service Cell Pathloss

158 IUO Path Loss Offset

159 Downlink Path Loss Offset

160 IBCA Max. Interference Source Num.

161 IBCA Soft Block SAIC Offset

162 IBCA AMR HR Soft Block Threshold

163 IBCA AMR FR Soft Block Threshold

164 IBCA HR Soft Block Threshold

165 IBCA FR/EFR Soft Block Threshold

166 IBCA Soft Block Switch

167 IUO IBCA Allowed

168 IBCA Allowed

169 Offset of the difference between uplink received levels(dBm)

170 Quality Thresh. for Assigning Main BCCH Carrier Channel Under TIGHT BCCH

171 Level Thresh. for Assigning Main BCCH Carrier Channel Under TIGHT BCCH

172 Power Priority Allowed

173 GSM900 Band Traffic Load Share Threshold

174 Channel Assignment Allowed for Insufficient Power

175 Down Power Inadequate Last Time

176 Down Power Inadequate Stat Time

177 Multi-Density Trx Power Sharing QTRUPWRSHARE SET GCELLCHMGAD

178 Observed time of uplink received level difference

179 Duration of uplink received level difference

180 Smooth factor of uplink received level

Ca

ll C

on

tro

lC

ha

nn

el

Ma

na

ge

me

nt

Page 5: 201081469 Huawei NSN Siemens Parameter

181 Threshold of the difference between uplink received levels

182 Allow Rate Selection Based on Overlaid/Underlaid Subcell Load

183 Busy Threshold of TCH Traffic in Underlaid Subcell TCHTRIBUSYUNDERLAYTHR SET GCELLCHMGAD

184 Busy Threshold of TCH Traffic in Overlaid Subcell TCHTRICBUSYOVERLAYTHR SET GCELLCHMGAD

185 Flex HSN Switch

186 Flex MAIO Switch FLEXMAIO ADD GCELL

187 Fix Abis Prior Choose Abis Load Threshold(%) FIXABISPRIORABISLOADTHRED SET BTSFLEXABISPARA

188 Flex Abis Prior Choose Abis Load Threshold(%)

189 TCH req suspend interval(s)

190 AMR TCH/H Prior Cell Load Threshold AMRTCHHPRIORLOAD SET GCELLCHMGAD

191 AMR TCH/H Prior Allowed

192 Update Freq.of CH Record

193 Update Period of CH Record(min)

194 Filter Length for SDCCH Qual.

195 Filter Length for SDCCH Level

196 Filter Length for TCH Qual.

197 Filter Length for TCH Level

198 Interf.of DL Qual.Threshold

199 Interf.of DL Level Threshold

200 Interf.of UL Qual. Threshold

201 Interf.of UL Level Threshold

202 Balance Traffic Allowed

203 History Record Priority Allowed

204 Allocation TRX Priority Allowed

205 Active CH Interf. Meas.Allowed

206 Interf. Priority Allowed

207 TCH Traffic Busy Threshold(%) TCHBUSYTHRES SET GCELLCHMGAD

208 Factory Mode

209 Different band SDCCH using optimize

210 Max Channel Num Reserved for EC

211 Ratio of AMR-HR(%)

212 Ratio of TCHH(%)

213 Quality First Highest Priority

214 Highest Priority User Quality First

215 TIGHT BCCH Switch

216 Dynamic Transmission Diversity(PBT) Supported

217 Channel Allocate Strategy CHALLOCSTRATEGY SET GCELLCHMGBASIC

218 Enhanced TCH Adjust Allowed

219 TCH Minimum Recovery Time(s) MINRESTIMETCH SET GCELLCHMGBASIC

220 Cell SDCCH Channel Maximum

221 Idle SDCCH Threshold N1

222 T3105(10ms) T3105 SET GCELLHOAD

223 Max Resend Times of Phy.Info. MAXRESEND SET GCELLHOAD

224 IniLev For EnUtoO Load HO

225 UL BQ HO Last Time(0.5s)

226 UL BQ HO Watch Time(0.5s)

Ha

nd

ov

er

Ch

an

ne

l M

an

ag

em

en

t

Page 6: 201081469 Huawei NSN Siemens Parameter

227 Inter-BSC Load Based Handover Allowed

228 Inter-RAT Load Based Handover Allowed

229 UQualOffset For Interfere HO

230 ULevOffset For Interfere HO(dbm)

231 DQualOffset For Interfere HO

232 DLevOffset For Interfere HO(dbm)

233 TA Filter Length for SDCCH Level

234 NCell Filter Length for SDCCH Level

235 Penalty Time on Interfere HO

236 Penalty Value on Load HO

237 Penalty Time on Load HO

238 Pathloss Ho. Enable

239 Inter-RAT Cell Reselection Enable INTERRATCELLRESELEN SET GCELLHOBASIC

240 Inter-RAT In BSC Handover Enable

241 Inter-RAT Out BSC Handover Enable

242 IntraCell Non-AMR TCHH-TCHF Ho Qual. Threshold

243 IntraCell Non-AMR TCHH-TCHF Ho Pathloss Threshold

244 IntraCell Non-AMR TCHH-TCHF Ho ATCB Threshold

245 IntraCell Non-AMR TCHH-TCHF Qaul. Ho Allowed

246 IntraCell Non-AMR TCHH-TCHF Traffic Threshold

247 IntraCell Non-AMR TCHF-TCHH Ho Qual. Threshold

248 IntraCell Non-AMR TCHF-TCHH Ho ATCB Threshold

249 IntraCell Non-AMR TCHF-TCHH Ho Pathloss Threshold

250 IntraCell Non-AMR TCHF-TCHH Ho ATCB Adjust Step

251 IntraCell Non-AMR TCHF-TCHH Ho Pathloss Adjust Step

252 IntraCell Non-AMR TCHF-TCHH Traffic Threshold

253 IntraCell Non-AMR TCHF-TCHH Ho Allowed

254 IntraCell TCHH-TCHF Ho Last Time(s)

255 IntraCell TCHH-TCHF Ho Stat Time(s)

256 IntraCell AMR TCHH-TCHF Ho Qual. Threshold

257 IntraCell TCHH-TCHF Pathloss Offset Overlay

258 IntraCell AMR TCHH-TCHF Ho Pathloss Threshold

259 IntraCell TCHH-TCHF ATCB Offset Overlay

260 IntraCell AMR TCHH-TCHF Ho ATCB Threshold

261 IntraCell TCHH-TCHF Ho Duration(s)

262 IntraCell AMR TCHH-TCHF Qaul Ho Allowed

263 IntraCell AMR TCHH-TCHF Traffic Threshold

264 IntraCell TCHF-TCHH Ho Last Time(s)

265 IntraCell TCHF-TCHH Ho Stat Time(s)

266 IntraCell AMR TCHF-TCHH Ho Qual. Threshold

267 IntraCell TCHF-TCHH ATCB Offset Overlay

268 IntraCell AMR TCHF-TCHH Ho ATCB Threshold

269 IntraCell TCHF-TCHH Pathloss Offset Overlay

270 IntraCell AMR TCHF-TCHH Ho Pathloss Threshold

271 IntraCell AMR TCHF-TCHH Ho ATCB Adjust Step

272 IntraCell AMR TCHF-TCHH Ho Pathloss Adjust Step

Ha

nd

ov

er

Page 7: 201081469 Huawei NSN Siemens Parameter

273 IntraCell TCHF-TCHH Ho Period(s)

274 IntraCell TCHF-TCHH Ho Duration(s)

275 IntraCell AMR TCHF-TCHH Traffic Threshold

276 IntraCell AMR TCHF-TCHH Ho Allowed

277 Better Cell HO Valid Time(s)

278 Better Cell HO Watch Time(s)

279 Better Cell Handover Enable

280 Interfere HO Valid Time(0.5s)

281 Interfere HO Static Time(0.5s)

282 HCS HO Valid Time(0.5s)

283 HCS HO Watch Time(0.5s)

284 BQ HO Valid Time(0.5s)

285 BQ HO Watch Time(0.5s)

286 TA HO Valid Time(0.5s)

287 TA HO Watch Time(Num of MR)(0.5s)

288 HO Control Switch

289 TDD Better 3G Cell HO Allowed

290 TDD 3G Better Cell HO Valid Time(s)

291 TDD 3G Better Cell HO Watch Time(s)

292 TDD RSCP Threshold for Better 3G Cell HO

293 TDD HO Preference Threshold for 2G Cell

294 TDD Inter-RAT HO Preference

295 Enable Quick PBGT HO Algorithm When MS Leaves BTS

296 Quick Handover Offset(dB)

297 Quick Handover Punish Value(dB)

298 Quick Handover Punish Time(s)

299 Number of Ignored Measurement Reports

300 Neighbor Cell Filter Length MR Number

301 Serving Cell Filter Length MR Number

302 Quick Handover Last Time (0.5s)

303 Quick Handover Static Time(0.5s)

304 Quick Move Speed Threshold(m/s)

305 Quick Handover Down Trigger Level(dB)

306 Quick Handover Up Trigger Level(dB)

307 Inner Cell Serious OverLoad Threshold(%)

308 Number of Satisfactory Measurements(s)

309 Total Number of Measurements(s)

310 Inter UL And OL Subcells HO Penalty Time(s)

311 Outgoing OL Subcell HO level Threshold(dB)

312 Incoming OL Subcell HO level Threshold(dB)

313 Step Length of OL Subcell Load HO(dB)

314 OL Subcell Load Diversity HO Period(s)

315 Load HO of OL Subcell to UL Subcell Enabled INNLOADHOEN SET GCELLHOEDBPARA

316 Modified Step Length of UL Load HO Period(s)

317 Step Length of UL Subcell Load HO(dB)

318 UL Subcell Load Hierarchical HO Period(s)

Ha

nd

ov

er

Page 8: 201081469 Huawei NSN Siemens Parameter

319 Load HO From UL Subcell to OL Subcell Allowed OUTLOADHOENABLE SET GCELLHOEDBPARA

320 Distance Hysteresis Between Boundaries of UL And OL Subcells(dB)

321 Distance Between Boundaries of UL And OL Subcells(dB)

322 Allowed Flow Control Level of UL And OL Subcell HO

323 UL Subcell Serious Overload Threshold(%)

324 UL Subcell General Overload Threshold(%) OUTGENOVERLDTHRED SET GCELLHOEDBPARA

325 Assignment Optimization of OL Subcell Allowed Or Not

326 Assignment Optimization of UL Subcell Allowed Or Not

327 UL Subcell Lower Load Threshold(%)

328 Better 3G Cell HO Allowed BET3GHOEN SET GCELLHOUTRANFDD

329 3G Better Cell HO Valid Time(s)

330 3G Better Cell HO Watch Time(s)

331 Ec/No Threshold for Better 3G Cell HO HOECNOTH3G SET GCELLHOUTRANFDD

332 RSCP Threshold for Better 3G Cell HO HORSCPTH3G SET GCELLHOUTRANFDD

333 HO Preference Threshold for 2G Cell

334 Inter-RAT HO Preference

335 Ps UtoO HO Received Level Threshold

336 Ps OtoU HO Received Level Threshold PSUTOORECEIVETHRSH SET GCELLHOIUO

337 ReceiveQualThrshAMRHR

338 ReceiveQualThrshAMRFR

339 En Iuo In Cell Load Classification HO Step

340 En Iuo In Cell Load Classification HO Period

341 En Iuo Out Cell Serious OverLoad Threshold ENSOVERLDTHRSH SET GCELLHOIUO

342 En Iuo Out Cell General OverLoad Threshold ENGOVERLDTHRSH SET GCELLHOIUO

343 En Iuo Out Cell Low Load Threshold ENLOWLDTHRSH SET GCELLHOIUO

344 MaxRetry Time after UtoO Fail

345 Penalty Time after OtoU HO Fail(s)

346 Penalty Time after UtoO HO Fail(s)

347 Penalty Time of UtoO HO(s)

348 Underlay HO Step Level

349 Underlay HO Step Period(s)

350 UtoO Traffic HO Allowed UTOOTRAFHOALLOW SET GCELLHOIUO

351 UtoO HO Received Level Threshold UTOORECTH SET GCELLHOIUO

352 OtoU HO Received Level Threshold OTOURECEIVETH SET GCELLHOIUO

353 Incoming-to-BSC HO Optimum Layer

354 Pref. Subcell in HO of Intra-BSC

355 TA Threshold of Imme-Assign Pref.

356 TA Pref. of Imme-Assign Allowed

357 TA Threshold of Assignment Pref. OPTITATHRES SET GCELLHOIUO

358 Assign-optimum-level Threshold OPTILEVTHRES SET GCELLHOIUO

359 Assign Optimum Layer

360 UO HO Valid Time(s)

361 UO HO Watch Time(s)

362 TA Hysteresis

363 TA Threshold TATHRES SET GCELLHOIUO

364 RX_QUAL Threshold

Ha

nd

ov

er

Page 9: 201081469 Huawei NSN Siemens Parameter

365 RX_LEV Hysteresis

366 RX_LEV Threshold

367 UO Signal Intensity Difference

368 TA for UO HO Allowed TAFORUOHOALLOW SET GCELLHOIUO

369 RX_QUAL for UO HO Allowed

370 RX_LEV for UO HO Allowed

371 OL to UL HO Allowed

372 UL to OL HO Allowed

373 Load Threshold for TIGHT BCCH HO

374 RX_QUAL Threshold for TIGHT BCCH HO

375 K Offset

376 UL Expected Level at HO Access

377 Penalty Time on Fast Moving HO(s) SPEEDPUNISHT SET GCELLHOAD

378 Penalty on Fast Moving Handover SPEEDPUNISH SET GCELLHOAD

379 Interval for Consecutive HO Jud. CONTINTV SET GCELLHOAD

380 Forbidden time after MAX Times BANTIME SET GCELLHOAD

381 MAX Consecutive HO Times MAXCNTNUM SET GCELLHOAD

382 MS Fast-moving Time Threshold

383 MS Fast-moving Valid Cells

384 MS Fast-moving Watch Cells

385 Load HO Step Level LOADHOSTEP SET GCELLHOAD

386 Load HO Step Period LOADHOPERIOD SET GCELLHOAD

387 Load HO Bandwidth LOADOFFSET SET GCELLHOAD

388 Load Req.on Candidate Cell(%)

389 Load HO Threshold(%) TRIGTHRES SET GCELLHOAD

390 System Flux Threshold for Load HO

391 ULQuaLimitAMRHR ULQuaLimitAMRHR SET GCELLAMRQUL

392 DLQuaLimitAMRHR DLQUALIMITAMRHR SET GCELLAMRQUL

393 ULQuaLimitAMRFR ULQUALIMITAMRFR SET GCELLAMRQUL

394 DLQuaLimitAMRFR DLQUALIMITAMRFR SET GCELLAMRQUL

395 RXLEVOff

396 RXQUAL12

397 RXQUAL11

398 RXQUAL10

399 RXQUAL9

400 RXQUAL8

401 RXQUAL7

402 RXQUAL6

403 RXQUAL5

404 RXQUAL4

405 RXQUAL3

406 RXQUAL2

407 RXQUAL1

408 Cons.No Dl Mr.HO Allowed Limit

409 No Dl Mr.Ul Qual HO Limit

410 No Dl Mr.HO Allowed

Ha

nd

ov

er

Page 10: 201081469 Huawei NSN Siemens Parameter

411 Filter Parameter B

412 Filter Parameter A8

413 Filter Parameter A7

414 Filter Parameter A6

415 Filter Parameter A5

416 Filter Parameter A4

417 Filter Parameter A3

418 Filter Parameter A2

419 Filter Parameter A1

420 UL Qual. Threshold ULQUALIMIT SET GCELLHOEMG

421 DL Qual. Threshold DLQUALIMIT SET GCELLHOEMG

422 Emergency HO TA Threshold

423 DtxMeasUsed

424 CfgPenaltyTimer

425 UmPenaltyTimer

426 RscPenaltyTimer

427 Filter Length for TCH NBR_RCVD_BLOCK

428 Filter Length for SDCCH NBR_RCVD_BLOCK

429 Penalty Time after AMR TCHF-H HO Fail(s)

430 Filter Length for TCH REP_QUANT

431 Filter Length for SDCCH REP_QUANT

432 Filter Length for TCH CV_BEP

433 Filter Length for SDCCH CV_BEP

434 Filter Length for TCH MEAN_BEP

435 Filter Length for SDCCH MEAN_BEP

436 Penalty Time after TA HO(s) TIMETAPUNISH SET GCELLHOFITPEN

437 Penalty Level after TA HO SSTAPUNISH SET GCELLHOFITPEN

438 Penalty Time after BQ HO(s) TIMEBQPUNISH SET GCELLHOFITPEN

439 Penalty Level after BQ HO SSBQPUNISH SET GCELLHOFITPEN

440 Penalty Level after HO Fail FAILSIGSTRPUNISH SET GCELLHOFITPEN

441 Filter Length for TA TAFLTLEN SET GCELLHOFITPEN

442 Filter Length for Ncell RX_LEV NCELLFLTLEN SET GCELLHOFITPEN

443 Filter Length for SDCCH Qual SIGQUAFLTLEN SET GCELLHOFITPEN

444 Filter Length for SDCCH Level.

445 Filter Length for TCH Qual DATAQUAFLTLEN SET GCELLHOFITPEN

446 Filter Length for TCH Level. DATASTRFLTLEN SET GCELLHOFITPEN

447 Allowed M.R Number Lost MRMISSCOUNT SET GCELLHOFITPEN

448 Min Power Level For Directed Retry

449 Sent Freq.of preprocessed MR

450 Transfer BS/MS Power Class

451 Transfer Original MR

452 MR.Preprocessing

453 Penalty Allowed

454 Inter-BSC SDCCH HO ALLowed INRBSCSDHOEN SET GCELLHOCTRL

455 Min Interval for Emerg.HOs

456 Min Interval for Consecutive HOs

Ha

nd

ov

er

Page 11: 201081469 Huawei NSN Siemens Parameter

457 Min Interval for SDCCH HOs

458 Min Interval for TCH HOs

459 ATCBHoSwitch

460 TIGHT BCCH HO Valid Time(s)

461 TIGHT BCCH HO Watch Time(s)

462 Quick Handover Enable

463 H2F HO Threshold

464 F2H HO Threshold

465 Intracell F-H HO Last Time(s)

466 Intracell F-H HO Stat Time(s)

467 Intracell F-H HO Allowed INTRACELLFHHOEN SET GCELLHOBASIC

468 Min DL Power on HO Candidate Cell HOCDCMINDWPWR SET GCELLHOBASIC

469 Min UP Power on HO Candidate Cell HOCDCMINUPPWR SET GCELLHOBASIC

470 Inter-layer HO Hysteresis LEVHOHYST SET GCELLHOBASIC

471 Inter-layer HO Threshold HOTHRES SET GCELLHOBASIC

472 PBGT Valid Time(s)

473 PBGT Watch Time(s)

474 Layer HO Valid Time(s)

475 Layer HO Watch Time(s)

476 Edge HO AdjCell Valid Time(s)

477 Edge HO AdjCell Watch Time(s)

478 Edge HO Valid Time(s)

479 Edge HO Watch Time(s)

480 Edge HO DL RX_LEV Threshold DLEDGETHRES SET GCELLHOBASIC

481 Edge HO UL RX_LEV Threshold ULEDGETHRES SET GCELLHOBASIC

482 Interference HO Allowed

483 Concentric Circles HO Allowed

484 TA HO Allowed TAHOEN SET GCELLHOBASIC

485 BQ HO Allowed BQHOEN SET GCELLHOBASIC

486 Edge Handover Allowed

487 Level HO Allowed LEVHOEN SET GCELLHOBASIC

488 PBGT HO Allowed PBGTHOEN SET GCELLHOBASIC

489 Rx_Level_Drop HO Allowed RXQCKFALLHOEN SET GCELLHOBASIC

490 MS Fast Moving HO Allowed QCKMVHOEN SET GCELLHOBASIC

491 Load HO Allowed LoadHoEn SET GCELLHOBASIC

492 Intracell HO Allowed INTRACELLHOEN SET GCELLHOBASIC

493 SDCCH HO Allowed SIGCHANHOEN SET GCELLHOBASIC

494 Co-BSC/MSC Adj

495 Timer For SD Fast Ho trig(s)

496 Channel Reserved for EC Protect Timer(s)

497 Timer for UL Data Forward(ms)

498 WaitforRelIndAMRHR

499 WaitforRelIndAMRFR

500 T3103C(ms) INTRACELLHOTIMER SET GCELLTMR

501 T3122(s) IMMREJWAITINDTIMER SET GCELLTMR

502 TREESTABLISH(ms)

Ha

nd

ov

er

Oth

er

Pro

pe

rtie

s

Page 12: 201081469 Huawei NSN Siemens Parameter

503 T3111(ms) DELAYSENDRFCHREL SET GCELLTMR

504 T3109(ms) WAITFORRELIND SET GCELLTMR

505 T8(ms) OUTBSCHOCLEARTIMER SET GCELLTMR

506 T3121(ms) INBSCHOTIMER SET GCELLTMR

507 T3107(ms) ASSTIMER SET GCELLTMR

508 T7(ms) OUTBSCHOCMDTIMER SET GCELLTMR

509 T3103A(ms) INTRABSCHOTIMER SET GCELLTMR

510 ImmAss A Interf Creation Timer(ms) IMMASSAINTERFTIMER SET GCELLTMR

511 T3101(ms) ESTABINDTIMER SET GCELLTMR

512 Cell Over Coverage TA Threshold

513 Cell Over Coverage Downlink RxLev Threshold

514 Cell Weak Coverage TA Threshold

515 Cell Weak Coverage Downlink RxLev Threshold

516 Main BCCH Trx Non-Bcch Time Slot Power Derating Active Channel Enable

517 Main BCCH Trx Non-Bcch Time Slot Power Derating Range

518 Main BCCH Trx Non-Bcch Time Slot Power Derating End Time

519 Main BCCH Trx Non-Bcch Time Slot Power Derating Start Time

520 Main BCCH Trx Non-Bcch Time Slot Power Derating Enable

521 MAX TA Drop Call Threshold(bit)

522 MAX TA Drop Call Filter(0.5s)

523 MAX TA Drop Call Switch

524 Frequency Hopping Coding Scheme

525 TSC Plan Enable

526 Switch for BTS Supporting SAIC Power Control Adjustment

527 PDCH Power Saving Enable

528 FER Report Enable

529 Report Downlink VQI Allowed

530 Timer for Bad Quality Disconnection Statistic(s)

531 Bad Quality Disconnection Threshold

532 Activate L2 Re-establishment

533 Send Classmark Enquiring Result To MSC Enable

534 Enquire Classmark After In-BSC Handover Enable

535 Base Hop Support Close TRX Allowed

536 STIRC Allowed

537 Voltage Adjust Based Timeslots Allowed

538 ICB Allowed

539 MS Capability Statistic Switch

540 Cell EFR Forced Switch

541 Qtru Signal Merge Switch

542 MAX Paging Message Number 0f Cell In Period

543 Average Paging Message Number 0f Cell In Period

544 Paging Numbers of one Optimizing Msgs

545 Interval For Sending Paging Optimizing Msgs

546 Paging Messages Optimize at Abis Interface

547 Interfere Band Stat Algorithm Type

548 Cell Out-of-Service Alarm Switch

Oth

er

Pro

pe

rtie

s

Page 13: 201081469 Huawei NSN Siemens Parameter

549 Lower-level sublink resources preemption switch

550 Sublink resources preemption switch

551 Force MS to Send Ho Access SWITCH

552 IntraCellHo to Ass SWITCH

553 Frequency Scan Result Type

554 Call Drop Optimization Intra-Cell Handover Timeout

555 Call Drop Optimization Intra-Bsc Out-Cell Handover Timeout

556 Call Drop Optimization Out-Bsc Handover Timeout

557 Call Drop Optimization In-BSC Handover Timeout

558 Call Drop Optimization Resource Check

559 Call Drop Optimization No MR For a Long Time

560 Call Drop Optimization Forced Handover Failure

561 Call Drop Optimization Equipment Failure

562 Call Drop Optimization ABIS Territorial Link Failure

563 Call Drop Optimization Release Indication

564 Call Drop Optimization Connection Failure (Other Causes)

565 Call Drop Optimization Connection Failure (Radio Resource Unavailable)

566 Call Drop Optimization Connection Failure (OM Intervention)

567 Call Drop Optimization Connection Failure (HO Access Failure)

568 Call Drop Optimization Connection Failure (Radio Link Failure)

569 Call Drop Optimization Error Indication (Sequence Error)

570 Call Drop Optimization Error Indication (Unsolicited DM Response)

571 Call Drop Optimization Error Indication (T200 Timeout)

572 Directly Magnifier Site Flag

573 Aiding Delay Protect Time(min)

574 SDCCH Congestion Flow Control Allowed

575 Support Half Rate HRATESPT SET GCELLCCCH

576 MS_TXPWR_MAX_CCH FMSMAXOPCC SET GCELLCCCH

577 Power Control Allowed

578 Activation Factor

579 Included Angle(Degree)

580 Antenna Azimuth Angle(Degree)

581 Average RACH Load Timeslot Number

582 Overload Indication Period

583 CCCH Load Threshold CCCHLOADTHRES SET GCELLCCCH

584 CCCH Load Indication Period(s) CCCHLOADINDPRD SET GCELLCCCH

585 Radio Resource Report Period(s) RFRESINDPRD SET GCELLCCCH

586 Diversity Transmitter 8PSK Delay(1/8bit)

587 Diversity Transmitter GMSK Delay(1/8bit)

588 Reserved TCH Number for PA Turning On

589 Frequency Adjust Value

590 Frequency Adjust Switch

591 VSWR TRX Error Threshold

592 VSWR TRX Unadjusted Threshold

593 Power Output Reduction Threshold

594 Power Output Error Threshold

Oth

er

Pro

pe

rtie

s

Page 14: 201081469 Huawei NSN Siemens Parameter

595 DC Bias Voltage Threshold

596 Frame Start Time

597 Max RC Power Reduction(2dB)

598 Interf.Calculation Period(SACCH period(480ms)) INTERPERIOD SET GCELLOTHEXT

599 Interf. Band Threshold 5 (-dBm)

600 Interf. Band Threshold 4 (-dBm)

601 Interf. Band Threshold 3 (-dBm)

602 Interf. Band Threshold 2 (-dBm)

603 Interf. Band Threshold 1 (-dBm)

604 Interf. Band Threshold 0 (-dBm)

605 Cell Directed Retry Forbidden Threshold

606 SMCBC DRX

607 Data service Allowed

608 Power boost before HO enabled or not

609 Voice quality report switch

610 Diversity LNA Bypass Permitted

611 HwIII DL RexQual Protect Factor

612 HwIII DL RexLev Protect Factor

613 HwIII UL RexQual Protect Factor

614 HwIII UL RexLev Protect Factor

615 HwIII DL Filter Adjust Factor

616 HwIII UL Filter Adjust Factor

617 HwIII Power Control Optimized Enable

618 0.2dB Power Control Enable

619 HwIII threshold Adjust for SAIC

620 HwIII MA FreqHop Gain 8(0.1dB)

621 HwIII MA FreqHop Gain 7(0.1dB)

622 HwIII MA FreqHop Gain 6(0.1dB)

623 HwIII MA FreqHop Gain 5(0.1dB)

624 HwIII MA FreqHop Gain 4(0.1dB)

625 HwIII MA FreqHop Gain 3(0.1dB)

626 HwIII MA FreqHop Gain 2(0.1dB)

627 HwIII MA FreqHop Gain 1(0.1dB)

628 HwIII UL MAX UpStep(dB)

629 HwIII UL MAX DownStep(dB)

630 HwIII UL AHS Rex Qual.Lower Threshold(dB) ULAHSREXQUALLOWTHRED SET GCELLPWR3

631 HwIII UL AHS Rex Qual.Upper Threshold(dB) ULAHSREXQUALHIGHTHRED SET GCELLPWR3

632 HwIII UL AFS Rex Qual.Lower Threshold(dB) ULAFSREXQUALLOWTHRED SET GCELLPWR3

633 HwIII UL AFS Rex Qual.Upper Threshold(dB) ULAFSREXQUALHIGHTHRED SET GCELLPWR3

634 HwIII UL HS Rex Qual.Lower Threshold(dB) ULHSREXQUALLOWTHRED SET GCELLPWR3

635 HwIII UL HS Rex Qual.Upper Threshold(dB) ULHSREXQUALHIGHTHRED SET GCELLPWR3

636 HwIII UL FS Rex Qual. Lower Threshold(dB) ULFSREXQUALLOWTHRED SET GCELLPWR3

637 HwIII UL FS Rex Qual. Upper Threshold(dB) ULFSREXQUALHIGHTHRED SET GCELLPWR3

638 HwIII UL RexLev Lower Threshold ULREXLEVLOWTHRED SET GCELLPWR3

639 HwIII UL RexLev Upper Threshold ULREXLEVHIGHTHRED SET GCELLPWR3

640 HwIII UL Rex Qual.Adjust Factor

Oth

er

Pro

pe

rtie

sP

ow

er

Co

ntr

ol

Page 15: 201081469 Huawei NSN Siemens Parameter

641 HwIII UL RexLev Adjust Factor

642 HwIII UL Rex Qual. Slide Window

643 HwIII UL RexLev Slide Window

644 HwIII UL Rex Qual.Exponent Filter Length

645 HwIII UL RexLev Exponent Filter Length

646 HwIII DL MAX UpStep (dB)

647 HwIII DL MAX DownStep(dB)

648 HwIII DL AHS Rex Qual. Lower Threshold(dB) DLAHSREXQUALLOWTHRED SET GCELLPWR3

649 HwIII DL AHS Rex Qual.Upper Threshold(dB) DLAHSREXQUALHIGHTHRED SET GCELLPWR3

650 HwIII DL AFS Rex Qual.Lower Threshold(dB) DLAFSREXQUALLOWTHRED SET GCELLPWR3

651 HwIII DL AFS Rex Qual.Upper Threshold(dB) DLAFSREXQUALHIGHTHRED SET GCELLPWR3

652 HwIII DL HS Rex Qual. Lower Threshold(dB) DLHSREXQUALLOWTHRED SET GCELLPWR3

653 HwIII DL HS Rex Qual. Upper Threshold(dB) DLHSREXQUALHIGHTHRED SET GCELLPWR3

654 HwIII DL FS Rex Qual. Lower Threshold(dB) DLFSREXQUALLOWTHRED SET GCELLPWR3

655 HwIII DL FS Rex Qual. Upper Threshold(dB) DLFSREXQUALHIGHTHRED SET GCELLPWR3

656 HwIII DL RexLev Lower Threshold DLREXLEVLOWTHRED SET GCELLPWR3

657 HwIII DL RexLev Upper Threshold DLREXLEVHIGHTHRED SET GCELLPWR3

658 HwIII DL Rex Qual. Adjust Factor

659 HwIII DL RexLev Adjust Factor

660 HwIII DL Rex Qual. Slide Window

661 HwIII DL RexLev Slide Window

662 HwIII DL Rex Qual. Exponent Filter Length

663 HwIII DL RexLev Exponent Filter Length

664 HwIII Traffic Channel Discard MR Number

665 HwIII Signal Channel Discard MR Number

666 HwIII Down Link Power Control Adjust Period

667 HwIII Up Link Power Control Adjust Period

668 HwIII Number of lost MRs allowed

669 Power Control threshold Adjust for SAIC

670 AMR BTS PC Class BTSPWRNUM SET GCELLPWR2

671 AMR DL Qual Bad UpLEVDiff

672 AMR DL Qual Bad Trig Threshold

673 AMR UL Qual. Bad UpLEVDiff

674 AMR UL Qual. Bad Trig Threshold

675 AMR MAX Up Adj. PC Value by Qual.

676 AMR MAX Up Adj. PC Value by RX_LEV

677 AMR MAX Down Adj. PC Value by Qual.

678 AMR MAX Down Adj. Value Qual. Zone 2

679 AMR MAX Down Adj. Value Qual. Zone 1

680 AMR MAX Down Adj. Value Qual. Zone 0

681 AMR DL Qual. Lower Threshold AMRDLQLTHRED SET GCELLPWR2

682 AMR DL Qual. Upper Threshold AMRDLQHTHRED SET GCELLPWR2

683 AMR DL RX_LEV Lower Threshold AMRDLSSLTHRED SET GCELLPWR2

684 AMR DL RX_LEV Upper Threshold AMRDLSSHTHRED SET GCELLPWR2

685 AMR UL Qual. Lower Threshold AMRULQLOWTHRED SET GCELLPWR2

686 AMR UL Qual. Upper Threshold AMRULQHTHRED SET GCELLPWR2

Po

we

r C

on

tro

l

Page 16: 201081469 Huawei NSN Siemens Parameter

687 AMR UL RX_LEV Lower Threshold AMRULSSLTHRED SET GCELLPWR2

688 AMR UL RX_LEV Upper Threshold AMRULSSHTHRED SET GCELLPWR2

689 AMR DL MR. Number Predicted

690 AMR UL MR. Number Predicted

691 AMR MR. Compensation Allowed AMRMRCOMPREG SET GCELLPWR2

692 AMR Filter Length for DL Qual. AMRDLQUAFTLEN SET GCELLPWR2

693 AMR Filter Length for UL Qual AMRULQUAFTLEN SET GCELLPWR2

694 AMR Filter Length for DL RX_LEV AMRDLLEVFTLEN SET GCELLPWR2

695 AMR Filter Length for UL RX_LEV AMRULLEVFTLEN SET GCELLPWR2

696 AMR PC Interval

697 BTS PC Class BTSPWRNUM SET GCELLPWR2

698 DL Qual. Bad UpLEVDiff

699 DL Qual. Bad Trig Threshold

700 UL Qual. Bad UpLEVDiff

701 UL Qual. Bad Trig Threshold

702 MAX Up Adj. PC Value by Qual.

703 MAX Up Adj. PC Value by RX_LEV

704 MAX Down Adj. PC Value by Qual.

705 MAX Down Adj.Value Qual.Zone 2

706 MAX Down Adj.Value Qual.Zone 1

707 MAX Down Adj.Value Qual.Zone 0

708 DL MR. Number Predicted

709 UL MR. Number Predicted

710 MR. Compensation Allowed MRCOMPREG SET GCELLPWR2

711 Filter Length for DL Qual. DLQUAFILTLEN SET GCELLPWR2

712 Filter Length for UL Qual. ULQUAFILTLEN SET GCELLPWR2

713 Filter Length for DL RX_LEV DLLEVFILTLEN SET GCELLPWR2

714 Filter Length for UL RX_LEV ULLEVFILTLEN SET GCELLPWR2

715 Expected UL RX_LEV

716 Expected DL RX_LEV

717 Path Loss of Different Frequency Band(0.1dB)

718 Double Antenna Gain(0.1dB)

719 Combiner Loss(0.1dB)

720 Power Forecast Allowed

721 AMR SACCH Downlink Power Upgrade

722 Power Control Algorithm Switch

723 DL Qual. Lower Threshold DLQLOWTHRED SET GCELLPWRBASIC

724 DL Qual. Upper Threshold DLQHIGHTHRED SET GCELLPWRBASIC

725 DL RX_LEV Lower Threshold DLSSLOWTHRED SET GCELLPWRBASIC

726 DL RX_LEV Upper Threshold DLSSHIGHTHRED SET GCELLPWRBASIC

727 UL Qual. Lower Threshold ULQLOWTHRED SET GCELLPWRBASIC

728 UL Qual. Upper Threshold ULQHIGHTHRED SET GCELLPWRBASIC

729 UL RX_LEV Lower Threshold ULSSLOWTHRED SET GCELLPWRBASIC

730 UL RX_LEV Upper Threshold ULSSHIGHTHRED SET GCELLPWRBASIC

731 PC Interval

Po

we

r C

on

tro

l

Page 17: 201081469 Huawei NSN Siemens Parameter

Parameter Name Sheet Location at Nfeed

EXCDIST SET BTS

ENCALSUP BSC

EBSPWRC PWRC

EMSPWRC PWRC

ENFORCHO BSC

DIRTCHASS BTS

RXLEVAMI BTS

CREALL BTS

PENTIME BTS

TEMPOFF BTS

CRESOFF BTS

CBQ BTS

CRESPARI BTS

CELLRESH BTS

T3212 BTS

NFRAMEPG BTS

NBLKACGR BTS

PLMNP BTS

CELLBARR BTS

NSLOTST BTS

IMSIATDT BTS

AMRHRIC BTS

AMRHRTH34 BTS

AMRHRTH23 BTS

AMRHRTH12 BTS

AMRHRTH34 BTS

AMRHRTH23 BTS

AMRHRTH12 BTS

AMRHRTH34 BTS

NSN (Siemens)

Page 18: 201081469 Huawei NSN Siemens Parameter

AMRHRTH23 BTS

AMRHRTH12 BTS

AMRHRTH34 BTS

AMRHRTH23 BTS

AMRHRTH12 BTS

AMRHRC1,AMRHRC2,AMRHRC3,AMRHRC4 SET BTS

AMRFRIC BTS

AMRFRTH34 BTS

AMRFRTH23 BTS

AMRFRTH12 BTS

AMRFRTH34 BTS

AMRFRTH23 BTS

AMRFRTH12 BTS

AMRFRTH34 BTS

AMRFRTH23 BTS

AMRFRTH12 BTS

AMRFRTH34 BTS

AMRFRTH23 BTS

AMRFRTH12 BTS

AMRFRC1,AMRFRC2,AMRFRC3,AMRFRC4 SET BTS

TDDREPTH BTS

TDDREPO BTS

TDDQO BTS

FDDREPTH BTS

FDDREPO BTS

QSRHC BTS

Page 19: 201081469 Huawei NSN Siemens Parameter

QSRHPRI PTPPKF

FDDQMI BTS

FDDMURREP BTS

FDDREPQTY BTS

FDDQO BTS

QSRHCINI BTS

QSRHI BTS

PWROFS BTS

NMULBAC BTS

EARCLM BTS

RDLNKTO BTS

EC BTS

NALLWACC BTS

MAXRETR BTS

T200 BTS

T200 BTS

T200 BTS

T200 BTS

T200 BTS

T200 BTS

T200 BTS

RACHBT BTS

RDLNKTO BTS

RDLNKTO BTS

RDLNKTBS PWRC

RDLNKTBS PWRC

Page 20: 201081469 Huawei NSN Siemens Parameter

RDLNKTBS PWRC

Page 21: 201081469 Huawei NSN Siemens Parameter

ENDMA SET BTS

ABISHRACTTHR BTSM

HRACTAMRT1 BTS

HRACTT1 BTS

T3105 BTS

NY1 BTS

Page 22: 201081469 Huawei NSN Siemens Parameter
Page 23: 201081469 Huawei NSN Siemens Parameter
Page 24: 201081469 Huawei NSN Siemens Parameter

EUBCHO HAND

USECNO ADJC3G

USRSCP ADJC3G

HORXLVDLO HAND

HORXLVDLI HAND

HOCCDIST HAND

HORXLVDLO HAND

HOCCDIST HAND

Page 25: 201081469 Huawei NSN Siemens Parameter

CCDIST HAND

TINOIERCHO HAND

MAIRACHO HAND

TRFMS HAND

TRFHOT HAND

TRFMMA HAND

TRFLTH HAND

TRFHITH HAND

Page 26: 201081469 Huawei NSN Siemens Parameter

HOLTHQUUL HAND

HOLTHQUDL HAND

HOAVDIST HAND

HOAVPWRB HAND

HOAVQUAL HAND

HOAVLEV HAND

HOAVQUAL HAND

HOAVLEV HAND

EISDCCHHO BSC

Page 27: 201081469 Huawei NSN Siemens Parameter

EADVCMPHOAMR HAND

RXLEVMIN ADJC

HOLTHLVDL HAND

HOLTHLVUL HAND

DISTHO HAND

RXQUALHO HAND

HIERC HAND

PBGTHO HAND

EFULHO HAND

DPBGTHO HAND

TRFHOE HAND

INTRACH HAND

IERCHOSDCCH HAND

T3122 BSC

Page 28: 201081469 Huawei NSN Siemens Parameter

T3111 BTS

T3109 BTS

BSCT8 BSC

BSCT3121 BSC

BSCT10 BSC

BSCT7 BSC

TCONN

T3101 BTS

Page 29: 201081469 Huawei NSN Siemens Parameter

HRSPEECH BSC

MSTXPMAXCH BTS

TCCCHLDI BTS

PCCCHLDI BTS

RFRSINDP BTS

Page 30: 201081469 Huawei NSN Siemens Parameter

INTAVEPR BTS

LOWTQUAU PWRC

UPTQUAU PWRC

LOWTQUAU PWRC

UPTQUAU PWRC

LOWTQUAU PWRC

UPTQUAU PWRC

LOWTQUAU PWRC

UPTQUAU PWRC

LOWTLEVU PWRC

UPTLEVU PWRC

Page 31: 201081469 Huawei NSN Siemens Parameter

LOWTQUAD PWRC

UPTQUAD PWRC

LOWTQUAD PWRC

UPTQUAD PWRC

LOWTQUAD PWRC

UPTQUAD PWRC

LOWTQUAD PWRC

UPTQUAD PWRC

LOWTLEVD PWRC

UPTLEVD PWRC

PCMBSTXPRL PWRC

LOWTQUAD PWRC

UPTQUAD PWRC

LOWTLEVD PWRC

UPTLEVD PWRC

LOWTQUAU PWRC

UPTQUAU PWRC

Page 32: 201081469 Huawei NSN Siemens Parameter

LOWTLEVU PWRC

UPTLEVU PWRC

PAVRQUAL PWRC

PAVRQUAL PWRC

PAVRLEV PWRC

PAVRLEV PWRC

PCMBSTXPRL PWRC

PAVRQUAL PWRC

PAVRQUAL PWRC

PAVRLEV PWRC

PAVRLEV PWRC

LOWTQUAD PWRC

UPTQUAD PWRC

LOWTLEVD PWRC

UPTLEVD PWRC

LOWTQUAU PWRC

UPTQUAU PWRC

LOWTLEVU PWRC

UPTLEVU PWRC