  • BSC6000

    Parameter Name Parameter Name Script Located1 Allow Dynamic Voltage Adjustment

    2 Allow Dynamic Shutdown of TRX Power Amplifier

    3 TCH/H Use Downlink DTX

    4 MAX TA(bit period(1 bit=0.55km)) MAXTA SET GCELLBASICPARA

    5 TCH/F Use Downlink DTX

    6 Encryption Algorithm ENCRY SET GCELLBASICPARA

    7 DL PC Allowed DNPCEN SET GCELLBASICPARA

    8 UL PC Allowed UPPCEN SET GCELLBASICPARA

    9 Directed Retry DIRECTRYEN SET GCELLBASICPARA

    10 TCH Immediate Assignment IMMASSEN SET GCELLBASICPARA

    11 TCH/H Uplink DTX

    12 RXLEV_ACCESS_MIN RXMIN SET GCELLBASICPARA

    13 Call Reestablishment Forbidden CALLRESTABDIS SET GCELLBASICPARA

    14 TCH/F Uplink DTX

    15 PT(s) PT SET GCELLIDLEAD

    16 TO TO SET GCELLIDLEAD

    17 Additional Reselect Param Indication ACS SET GCELLIDLEAD

    18 CRO(2dB) CRO SET GCELLIDLEBASIC

    19 Cell_Bar_Qualify CBQ SET GCELLIDLEBASIC

    20 PI PI SET GCELLIDLEBASIC

    21 CRH(dB) CRH SET GCELLIDLEBASIC

    22 Period of Periodic Location Update(6 minutes) T3212 SET GCELLIDLEBASIC

    23 BS-PA-MFRAMS BSPAMFRAMS SET GCELLIDLEBASIC

    24 BS_AG_BLKS_RES BSAGBLKSRES SET GCELLIDLEBASIC

    25 NCC Permitted NCCPERMITED SET GCELLEXTMSRPARA

    26 Cell_Bar_Access CBA SET GCELLIDLEBASIC

    27 Tx-integer TX SET GCELLIDLEBASIC

    28 Attach/Detach Allowed ATT SET GCELLIDLEBASIC

    29 Threshold Adjust Factor

    30 Long-term FER Target

    31 Long-term FER Lower Threshold

    32 Long-term FER Upper Threshold

    33 AMR Uplink Adaptive Threshold Allowed

    34 AMR TFO Switch

    35 AMR Starting Mode(H) INITCDMDH SET GCELLCCAMR

    36 AMR DL Coding Rate adj.hyst3(H) DLHYSTH3 SET GCELLCCAMR

    37 AMR DL Coding Rate adj.hyst2(H) DLHYSTH2 SET GCELLCCAMR

    38 AMR DL Coding Rate adj.hyst1(H) DLHYSTH1 SET GCELLCCAMR

    39 AMR DL Coding Rate adj.th3(H) DLTHH3 SET GCELLCCAMR

    40 AMR DL Coding Rate adj.th2(H) DLTHH2 SET GCELLCCAMR

    41 AMR DL Coding Rate adj.th1(H) DLTHH1 SET GCELLCCAMR

    42 AMR UL Coding Rate adj.hyst3(H) ULHYSTH3 SET GCELLCCAMR

    Basic

    Att

    rib

    ute

    sId

    le M

    od

    eC

    all

    Co

    ntr

    ol

    BSC6900No Group

  • 43 AMR UL Coding Rate adj.hyst2(H) ULHYSTH2 SET GCELLCCAMR

    44 AMR UL Coding Rate adj.hyst1(H) ULHYSTH1 SET GCELLCCAMR

    45 AMR UL Coding Rate adj.th3(H) ULTHH3 SET GCELLCCAMR

    46 AMR UL Coding Rate adj.th2(H) ULTHH2 SET GCELLCCAMR

    47 AMR UL Coding Rate adj.th1(H) ULTHH1 SET GCELLCCAMR

    48 AMR ACS(H)(Kbit/s) ACTCDSETH SET GCELLCCAMR

    49 AMR Starting Mode(F) INITCDMDF SET GCELLCCAMR

    50 AMR DL Coding Rate adj.hyst3(F) DLHYSTF3 SET GCELLCCAMR

    51 AMR DL Coding Rate adj.hyst2(F) DLHYSTF2 SET GCELLCCAMR

    52 AMR DL Coding Rate adj.hyst1(F) DLHYSTF1 SET GCELLCCAMR

    53 AMR DL Coding Rate adj.th3(F) DLTHF3 SET GCELLCCAMR

    54 AMR DL Coding Rate adj.th2(F) DLTHF2 SET GCELLCCAMR

    55 AMR DL Coding Rate adj.th1(F) DLTHF1 SET GCELLCCAMR

    56 AMR UL Coding Rate adj.hyst3(F) ULHYSTF3 SET GCELLCCAMR

    57 AMR UL Coding Rate adj.hyst2(F) ULHYSTF2 SET GCELLCCAMR

    58 AMR UL Coding Rate adj.hyst1(F) ULHYSTF1 SET GCELLCCAMR

    59 AMR UL Coding Rate adj.th3(F) ULTHF3 SET GCELLCCAMR

    60 AMR UL Coding Rate adj.th2(F) ULTHF2 SET GCELLCCAMR

    61 AMR UL Coding Rate adj.th1(F) ULTHF1 SET GCELLCCAMR

    62 AMR ACS(F)(Kbit/s) ACTCDSETF SET GCELLCCAMR

    63 EMC Priority Level

    64 Emergency Call Preemption Permitted

    65 Max Assignment Retry Times

    66 Frequency Band of Reassign

    67 Short Message Downlink Disabled

    68 Short Message Uplink Disabled

    69 Immediate Assignment Opt.

    70 Repeated SACCH

    71 Repeated Downlink FACCH Threshold

    72 Repeated Downlink FACCH

    73 Abis Resource Adjustment TCHH Function Switch

    74 Allow EMLPP

    75 Allow Reassign

    76 TDD MI System Information Broadcasting Prohibit

    77 TDD System Information Optimized Allowed

    78 TDD Cell Threshold TDDCELLTHRED SET GCELLCCUTRANSYS

    79 TDD Cell offset TDDCELLOFF SET GCELLCCUTRANSYS

    80 Best TDD Cell Number

    81 TDD Cell Reselect Diversity(dB) TDDCELLRESELDIV SET GCELLCCUTRANSYS

    82 FDD Reporting Threshold FDDCELLTHRED SET GCELLCCUTRANSYS

    83 FDD Reporting Offset FDDCELLOFF SET GCELLCCUTRANSYS

    84 1800M Reporting Threshold

    85 1800M Reporting Offset

    86 900M Reporting Threshold

    87 900M Reporting Offset

    88 Qsearch C QSEARCHC SET GCELLCCUTRANSYS

    Ca

    ll C

    on

    tro

    l

  • 89 Scale Order

    90 Invalid BSIC Reporting

    91 3G Search PRIO

    92 Qsearch P QP SET GCELLCCUTRANSYS

    93 FDD Qmin FDDQMIN SET GCELLCCUTRANSYS

    94 FDD MULTIRAT Reporting FDDFREQCNUM SET GCELLCCUTRANSYS

    95 FDD REP QUANT FDDREP SET GCELLCCUTRANSYS

    96 FDD Q Offset FDDQOFF SET GCELLCCUTRANSYS

    97 Qsearch C Initial QCI SET GCELLCCUTRANSYS

    98 Qsearch I QI SET GCELLCCUTRANSYS

    99 Serving Band Reporting

    100 Power Deviation(2dB) PWRDIV SET GCELLCCACCESS

    101 Power Deviation Indication

    102 MBR MBR SET GCELLCCBASIC

    103 ECSC ECSC SET GCELLCCBASIC

    104 Radio Link Timeout(SACCH period (480ms)) RLT SET GCELLCCBASIC

    105 Emergent Call Disable ERGCALLDIS SET GCELLCCBASIC

    106 Special Access Control Class

    107 Common Access Control Class COMMACC SET GCELLCCBASIC

    108 MS MAX Retrans(Time) MSMAXRETRAN SET GCELLCCBASIC

    109 Max Transmit Times of Imm_Ass

    110 Max Delay of Imm_Ass Retransmit(ms)

    111 Use Imm_Ass Retransmit Parameter

    112 N200 of FACCH/Full rate N200FFULL SET GCELLCCTMR

    113 N200 of FACCH/Half rate N200FHALF SET GCELLCCTMR

    114 N200 of SDCCH N200SDCCH SET GCELLCCTMR

    115 N200 of SACCH N200SACCH SET GCELLCCTMR

    116 N200 of Release

    117 N200 of Establish

    118 Use LAPDm N200

    119 T200 SDCCH SAPI3(5ms) T200SDCCH3 SET GCELLCCTMR

    120 T200 SACCH SDCCH(10ms) T200SACCHS SET GCELLCCTMR

    121 T200 SACCH TCH SAPI3(10ms) T200SACCH3 SET GCELLCCTMR

    122 T200 SACCH TCH SAPI0(10ms) T200SACCT0 SET GCELLCCTMR

    123 T200 FACCH/H(5ms) T200FACCHH SET GCELLCCTMR

    124 T200 FACCH/F(5ms) T200FACCHF SET GCELLCCTMR

    125 T200 SDCCH(5ms) T200SDCCH SET GCELLCCTMR

    126 RACH Min.Access Level(dbm) RACHACCLEV SET GCELLCCACCESS

    127 Random Access Error Threshold

    128 TRX Aiding Function Control

    129 Speech Version SPEECHVERSION SET BTSCHNFALLBACK

    130 AHR Radio Link Timeout(SACCH period (480ms)) AHRDSBLCNT SET GCELLCCBASIC

    131 AFR Radio Link Timeout(SACCH period (480ms)) AFRDSBLCNT SET GCELLCCBASIC

    132 AHR SACCH Multi-Frames(SACCH period (480ms)) AHRSAMULFRM SET GCELLCCBASIC

    133 AFR SACCH Multi-Frames(SACCH period (480ms)) AFRSAMULFRM SET GCELLCCBASIC

    134 Directed Retry Load Access Threshold

    Ca

    ll C

    on

    tro

    l

  • 135 Assignment Cell Load Judge Enable

    136 Paging Times

    137 RACH Busy Threshold

    138 SACCH Multi-Frames(SACCH period (480ms)) SAMULFRM SET GCELLCCBASIC

    139 IBCA Init. Power Control Rx Qual UL Offset

    140 IBCA Init. Power Control Rx Qual DL Offset

    141 IBCA Init. Power Control RexLevUL Offset

    142 IBCA Init. Power Control RexLevDL Offset

    143 Handover to Overlayer RxLev Offset(dB)

    144 Assign to Overlayer RxLev Offset(dB)

    145 Low Rxlev Overlayer Forbid Allocation Switch

    146 IBCA Path Lose Filter Factor

    147 IBCA ICDM Switch

    148 IBCA Wait SDCCH Idle Timer(s)

    149 IBCA Tight Trx SDCCH Rxlev Thredhold(dB)

    150 IBCA Loose Trx SDCCH Load Thredhold(%)

    151 C/I Estimate Value(dB)

    152 Non-AMR User Allocate Loose Frequency Reuse Mode Trx Preference

    153 IBCA Call Information Filter Length

    154 IBCA Dynamic Measure Neighbor Cell Allowed

    155 IBCA Waiting Measurement Report Time(0.5s)

    156 IBCA Pathloss Offset

    157 IBCA Service Cell Pathloss

    158 IUO Path Loss Offset

    159 Downlink Path Loss Offset

    160 IBCA Max. Interference Source Num.

    161 IBCA Soft Block SAIC Offset

    162 IBCA AMR HR Soft Block Threshold

    163 IBCA AMR FR Soft Block Threshold

    164 IBCA HR Soft Block Threshold

    165 IBCA FR/EFR Soft Block Threshold

    166 IBCA Soft Block Switch

    167 IUO IBCA Allowed

    168 IBCA Allowed

    169 Offset of the difference between uplink received levels(dBm)

    170 Quality Thresh. for Assigning Main BCCH Carrier Channel Under TIGHT BCCH

    171 Level Thresh. for Assigning Main BCCH Carrier Channel Under TIGHT BCCH

    172 Power Priority Allowed

    173 GSM900 Band Traffic Load Share Threshold

    174 Channel Assignment Allowed for Insufficient Power

    175 Down Power Inadequate Last Time

    176 Down Power Inadequate Stat Time

    177 Multi-Density Trx Power Sharing QTRUPWRSHARE SET GCELLCHMGAD

    178 Observed time of uplink received level difference

    179 Duration of uplink received level difference

    180 Smooth factor of uplink received level

    Ca

    ll C

    on

    tro

    lC

    ha

    nn

    el

    Ma

    na

    ge

    me

    nt

  • 181 Threshold of the difference between uplink received levels

    182 Allow Rate Selection Based on Overlaid/Underlaid Subcell Load

    183 Busy Threshold of TCH Traffic in Underlaid Subcell TCHTRIBUSYUNDERLAYTHR SET GCELLCHMGAD

    184 Busy Threshold of TCH Traffic in Overlaid Subcell TCHTRICBUSYOVERLAYTHR SET GCELLCHMGAD

    185 Flex HSN Switch

    186 Flex MAIO Switch FLEXMAIO ADD GCELL

    187 Fix Abis Prior Choose Abis Load Threshold(%) FIXABISPRIORABISLOADTHRED SET BTSFLEXABISPARA

    188 Flex Abis Prior Choose Abis Load Threshold(%)

    189 TCH req suspend interval(s)

    190 AMR TCH/H Prior Cell Load Threshold AMRTCHHPRIORLOAD SET G