Upload
doanminh
View
223
Download
1
Embed Size (px)
Citation preview
VIESMANN VITOCAL 200-SAir/water heat pump, split version
3.0 to 10.6 kW
VITOCAL 200-S Type AWS
Split heat pump with electric drive in split design with externalunits and internal devices.For central heating and DHW in heating systems.■ Internal device with Vitotronic 200 heat pump control unit,
heating circuit pump, 3-way diverter valve, expansion vesseland safety assembly.
■ Weather-resistant external unit with evaporator, compressor,electronic expansion valve and fan.
Permissible operating pressure: Heating water 3 bar
VITOCAL 200-S Type AWS-AC
Equipped as type AWS with additional cooling function via theheating circuit and integral instantaneous heating waterheater.
5822 525 GB 9/2010
DatasheetFor part no. and prices: see pricelist
Internal device
A Expansion vesselB CondenserC 3-way diverter valve heating/DHWD Heating circuit pumpE Vitotronic 200, type WO1A
■ Variable output control with DC inverter technology.■ High coefficient of performance: COP to EN 14511 up to 3.5 (air 2 ºC/
water 35 ºC) or up to 4.6 (air 7 ºC/water 35 ºC).(COP = coefficient of performance).
■ Maximum flow temperature : up to 55 ºC.■ Easy-to-operate Vitotronic control unit with plain text and graphic
display.■ The programming unit part of the control unit can also be fitted on a
wall mounting base.
■ No risk from frost for the connection lines between the external andinternal devices.
■ Cooling (type AWS-AC) in conjunction with fan convectors or under-floor heating system.
■ Low operating noise through reduced fan speed in partial load oper-ation.
■ High seasonal performance factor through high efficiency in partialload operation.
Benefits
2 VIESMANN VITOCAL 200-S
5822
525
GB
Specification
Vitocal 200-SType AWS/AWS-AC 104 107 110 113Heating output data at 100 % to EN 14511(A2/W35 °C, spread 5 K)
Rated output kW 3.0 5.6 7.7 10.6Compressor frequency Hz 60 65 55 75Fan speed rpm 870 650 650 650Power consumption kW 0.91 1.73 2.20 3.25Coefficient of performance ε (COP) inheating mode
3.30 3.24 3.50 3.26
Heating output data at 100 % to EN 14511(A7/W35 °C, spread 5 K)
Rated output kW 4.5 8.0 10.9 14.6Compressor frequency Hz 60 65 55 75Fan speed rpm 870 650 650 650Power consumption kW 0.97 1.88 2.36 3.40Coefficient of performance ε (COP) inheating mode
4.64 4.26 4.62 4.29
Output control kW 1.2 – 5.3 1.8 – 9.5 5.0 – 14.0 5.0 – 16.1Cooling capacity data at 100 % to EN 14511(A35/W7 °C, spread 5 K)
Rated cooling capacity kW 3.2 6.2 7.4 9.1Compressor frequency Hz 60 65 55 70Fan speed rpm 870 650 650 650Power consumption kW 1.08 2.40 2.69 3.64Energy efficiency ratio ε (EER) in coolingmode
2.96 2.60 2.75 2.50
Output control kW 1.2 – 3.8 1.6 – 8.0 2.4 – 8.5 2.4 – 10.0Cooling capacity data at 100 % to EN 14511(A35/W18 °C, spread 5 K)
Rated cooling capacity kW 4.2 8.8 10.0 12.6Compressor frequency Hz 60 65 55 70Fan speed rpm 870 650 650 650Power consumption kW 1.13 2.63 2.80 4.20Energy efficiency ratio ε (EER) in coolingmode
3.72 3.35 3.57 3.00
Air intake temperature Heating – Min. °C –15 –15 –15 –15– Max. °C 35 35 35 35Cooling (only type AWS-AC) – Min. °C 15 15 15 15– Max. °C 45 45 45 45Heating water at 5 K spread
Content (excl. expansion vessel) l 2.2 2.2 3.2 3.2Min. flow rate l/h 600 820 1200 1380Max. external pressure drop (RFH) at min.flow rate
mbar 590 540 440 380
Max. flow temperature °C 55 55 55 55Electrical values External unit – Rated voltage, compressor 1/N/PE 230 V/50 Hz– Rated current, compressor (max.) A 5 9 10 15– Starting current, compressor A 10.5 15 10 10– Starting current, compressor with stalled
armatureA 20 25 32 32
– Internal fuse A 3.5 3.5 3.15 3.15– IP rating IP 25 25 25 25
Specification
VITOCAL 200-S VIESMANN 3
5822
525
GB
Type AWS/AWS-AC 104 107 110 113Electrical values Internal device Heat pump control unit/PCB – Rated voltage control unit/PCB 1/N/PE 230 V/50 Hz– Fuse protection, power supply 1xB16A– Internal fuse 6.3 A (slow) / 250 VInstantaneous heating water heater(phase asymmetrical)Integral for type AWS-AC
– Rated voltage 3/N/PE 400 V/50 Hz– Heating output kW 9 9 9 9– Fuse protection, power supply 3xB16A 3xB16A 3xB16A 3xB16AIP rating IP 20 20 20 20Power consumption – Fan (max.) W 65 70 130 130– External unit (max.) kW 3.0 3.6 5.8 5.8– Secondary pump at stage 3/2/1 W 132/92/62 132/92/62 132/92/62 132/92/62– Control unit/PCB, external unit (max.) W 150 150 150 150– Control unit/PCB, internal device (max.) W 5 5 5 5– Max. nominal rating, control unit/PCB W 1000 1000 1000 1000Refrigerant circuit Refrigerant R410A R410A R410A R410AFill volume kg 1.2 2.1 2.95 2.95Top-up amount for line lengths from 12 mto 30 m
g/m 20 60 60 60
Compressor (hermetically sealed) Type Rotating piston Rotating piston Scroll ScrollPermiss. operating pressure – High pressure side bar
MPa434.3
434.3
434.3
434.3
– Low pressure side barMPa
434.3
434.3
434.3
434.3
Dimensions External unit Total length (depth) mm 290 340 340 340Total width mm 869 1040 900 900Total height mm 610 865 1255 1255Internal device Total length (depth) mm 360 360 360 360Total width mm 450 450 450 450Total height mm 850 850 850 850Total weight External unit kg 43 66 110 110Internal device kg 35 35 40 40Permiss. operating pressure, secondaryside
barMPa
30.3
30.3
30.3
30.3
Connections Heating water flow G 1¼ 1¼ 1¼ 1¼Heating water return and DHW cylinderreturn
G 1¼ 1¼ 1¼ 1¼
DHW cylinder flow G 1¼ 1¼ 1¼ 1¼Condensate line mm 16 16 16 16Liquid gas line – Pipe 7 mm 6 10 10 10– Internal device UNF ⅝ ⅝ ⅝ ⅝– External unit UNF ⁷⁄₁₆ ⅝ ⅝ ⅝Hot gas line – Pipe 7 mm 12 16 16 16– Internal device UNF ⅞ ⅞ ⅞ ⅞– External unit UNF ¾ ⅞ ⅞ ⅞Max. line length, liquid gas line, hot gasline
m 25 30 30 30
Max. height differential between the inter-nal device and the external unit
m 10 15 15 15
Specification (cont.)
4 VIESMANN VITOCAL 200-S
5822
525
GB
Type AWS/AWS-AC 104 107 110 113Weighted total sound power level(external unit)Test with reference to DIN EN 12102/DIN EN ISO 9614-2 under the followingconditions: Inlet temperature 7 °C ±3 K,flow temperature 35 °C ±5 K
at rated heating output dB(A) 60 62 62 63
Dimensions
Internal device
850
450
114
105
116
360
+
230 V~400 V~
<42 V >42 V
1160
A
Specification (cont.)
VITOCAL 200-S VIESMANN 5
5822
525
GB
10010
00100
230 V~
<42 V >42 V400 V~
Symbol Explanation Connection Refrigerant lines from/to the external unit:
– Hot gas line – 4 kW: 7 12 mm– 7 kW: 7 16 mm–10 kW: 7 16 mm–13 kW: 7 16 mm
– Liquid gas line – 4 kW: 7 6 mm– 7 kW: 7 10 mm–10 kW: 7 10 mm–13 kW: 7 10 mm
DHW cylinder flow (heating water side) G 1¼
+
Heating water return and DHW cylinder return G 1¼
Heating water flow G 1¼
A Drain & fill valve — Safety valve —
Specification (cont.)
6 VIESMANN VITOCAL 200-S
5822
525
GB
External unit
Type AWS/AWS-AC 104
74
293
29061
0
500
40
795869
Specification (cont.)
VITOCAL 200-S VIESMANN 7
5822
525
GB
Type AWS/AWS-AC 107
340 9501040
865
527
378
90
Specification (cont.)
8 VIESMANN VITOCAL 200-S
5822
525
GB
Type AWS/AWS-AC 110 and 113
340
1225
900
705 97357
437
Specification (cont.)
VITOCAL 200-S VIESMANN 9
5822
525
GB
10 VIESMANN VITOCAL 200-S
5822
525
GB
Prin
ted
on e
nviro
nmen
tally
frie
ndly
,ch
lorin
e-fre
e bl
each
ed p
aper
Subject to technical modifications.
Viessmann LimitedHortonwood 30, TelfordShropshire, TF1 7YP, GBTelephone: +44 1952 675000Fax: +44 1952 675040E-mail: [email protected]
Viessmann Werke GmbH&Co KGD-35107 AllendorfTelephone: +49 6452 70-0Fax: +49 6452 70-2780www.viessmann.com