W e s u p p o r t y o u r i n n o v a t i o n
HIGHLIGHTS
GP 50
The GP 50 pump still maintains its original configuration with the twocopper current feedthrough protruding out of the base flange. It usesboth St 707 and St 101 getter cartridges mounted on a heater structurebased on a single heater element, and is available on CF35 (2 3/4”)flange. The pumping speed curves and the activation curves are shownin the enclosed graphs.
GP 50 2F
Ordering Information
Base Flange with Heater
Base Flange with Heater and Water Cooled Body
St 101 Getter Cartridge on Iron Substrate
St 101 Getter Cartridge on Constantan Substrate
St 707 Getter Cartridge on Constantan Substrate
4H0305
4H0295
4H0030
4H0065
4H0205
GP 50 2F
GP 50 W2F
C 50-St101
C 50-St101AM
C 50-St707
General features
High pumping speed for all active gases
Constant pumping speed in
HV and UHV pressure region
No low pressure limitation
(down to 10-12 Torr region)
Reversible pumping of hydrogen
and its isotopes
Possibility of operation at room
temperature after activation, without
power
Operation in the presence of high
magnetic fields
Oil free and vibration free ultra high
vacuum
Low weight
Applications
Improving ultimate vacuum in
combination with ion, diffusion,
cryogenetic or turbomolecular pumps
Surface analysis systems
Particle accelerators, synchrotron
radiation sources and related
equipment
Process pumps for vacuum devices
Portable vacuum instrumentation
Pumping, storing and releasing
hydrogen isotopes
Plasma machines
Hydrogen traps
Impurities removal in rare gas filled
devices
ø 70
10
Dimensions in mm
172
186
2001 ©SAES Getters. Printed in Italy. All rights reserved. Sorb-Ac® is a trademark of SAES Getters.SAES Getters reserves the right to change or modify product specifications at any time without notice.
Lainate (Italy)
Avezzano (Italy)
Köln (Germany)
Moscow (Russia)
Paris (France)
Daventry (UK)
Nanjing (China)
Shanghai (China)
Tokyo (Japan)
Seoul (Korea)
Chin Chon (Korea)
Singapore
Hsin Chu (Taiwan)
Cleveland OH (USA)
Colorado Springs CO (USA)
San Luis Obispo CA (USA)
Sparks MD (USA)
D.VS.03.02
SAES Getters S.p.A.Group Headquarters:Viale Italia,7720020 Lainate (Milano), ItalyTel.: + 39 02 931 78 1Fax: + 39 02 931 78 320
www.saesgetters.com
SAES AdvancedTechnologies S.p.A.Nucleo Industriale:Via Diesel,167051 Avezzano (AQ), ItalyTel.: + 39 0863 495 1Fax: + 39 0863 267 43
Typical Pump Characteristics
Note: Pumping speed data refer to the initial values of the pump without thepump body. CO capacity based on speed below 10 l/s.
Alloy Type
Getter Alloy Mass (g)
Getter Surface (cm2)
PumpingSpeed (I/s)
SorptionCapacity(Torr I)
H2
CO
H2
CO
St 101
24
830
210
110
240
St 707
32
830
200
100
320
CO Total
CO Room Temperature 0,55
215
0,55
290
Conversion Tablesought
Pa mbar Torr
1 Pa
1 mbar
1 Torr
1 10-2 750.06x 10-5
102 1 0.75006
133.322 1.333 1
given
Pu
mp
ing
Sp
eed
(I/s
)
GP50 2F St707
1
10
100
1000
0,001 0,01 0,1 1 10 100
Sorbed Quantity (Torr. l)nude with water cooled body
Sorption temperature: 25 °C Activation: 450 °C x 45' Sorption pressure: 3e-6 Torr
H2
COVo
ltag
e (V
)
Cu
rren
t (A
)
GP50 W2F
Temperature (°C)
Voltage (V) Current (A)
0
5
10
15
20
25
30
35
40
45
50
50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800
0
0,5
1
1,5
2
2,5
3
3,5
4
4,5
5
W e s u p p o r t y o u r i n n o v a t i o n
HIGHLIGHTS
GP 100 MK5
The GP 100 MK5 pump uses an St 707 getter cartridge mounted on aheater structure based on a single heater element, and is available onCF63 (4 1/2”) flange.The flange is conveniently supplied with a custom-made, bakeableelectrical connector which combines power and thermocouple pins, forbest integration and minimum footprint.The pump sorption speed is at its maximum when mounted directly inthe vacuum system without a body.The pumping speed curves and the activation curves are shown in theenclosed graphs.
GP 100 MK5
Ordering Information
Base Flange with Connector and Heater
Base Flange with Connector, Heater and Body
Base Flange with Connector, Heater andWater Cooled Body
St 707 Getter Cartridge on Constantan Substrate
4H0273
4H0450
4H0451
4H0250
GP 100 MK5
GP 100 MK5 B
GP 100 MK5 W
C 100-MK5 St707
ø 114
218
163
ø 46
ø 60
getterssaes
33
General features
High pumping speed for all active gases
Constant pumping speed in
HV and UHV pressure region
No low pressure limitation
(down to 10-12 Torr region)
Reversible pumping of hydrogen
and its isotopes
Possibility of operation at room
temperature after activation, without
power
Operation in the presence of high
magnetic fields
Oil free and vibration free ultra high
vacuum
Low weight
Applications
Improving ultimate vacuum in
combination with ion, diffusion,
cryogenetic or turbomolecular pumps
Surface analysis systems
Particle accelerators, synchrotron
radiation sources and related
equipment
Process pumps for vacuum devices
Portable vacuum instrumentation
Pumping, storing and releasing
hydrogen isotopes
Plasma machines
Hydrogen traps
Impurities removal in rare gas filled
devices
Dimensions in mm
2001 ©SAES Getters. Printed in Italy. All rights reserved. Sorb-Ac® is a trademark of SAES Getters.SAES Getters reserves the right to change or modify product specifications at any time without notice.
Lainate (Italy)
Avezzano (Italy)
Köln (Germany)
Moscow (Russia)
Paris (France)
Daventry (UK)
Nanjing (China)
Shanghai (China)
Tokyo (Japan)
Seoul (Korea)
Chin Chon (Korea)
Singapore
Hsin Chu (Taiwan)
Cleveland OH (USA)
Colorado Springs CO (USA)
San Luis Obispo CA (USA)
Sparks MD (USA)
D.VS.03.02
SAES Getters S.p.A.Group Headquarters:Viale Italia,7720020 Lainate (Milano), ItalyTel.: + 39 02 931 78 1Fax: + 39 02 931 78 320
www.saesgetters.com
SAES AdvancedTechnologies S.p.A.Nucleo Industriale:Via Diesel,167051 Avezzano (AQ), ItalyTel.: + 39 0863 495 1Fax: + 39 0863 267 43
Typical Pump Characteristics
PumpingSpeed (I/s)
Alloy Type St 707
Getter Alloy Mass (g) 100
Getter Surface (cm2) 2600
H2 600
CO 300
H2 1000
CO Room Temperature 2.1
CO Total 900
SorptionCapacity(Torr I)
Note: Pumping speed data refer to the initial values of the pumpwithout the pump body. CO capacity based on speed below 30 l/s.
Conversion Tablesought
Pa mbar Torr
1 Pa
1 mbar
1 Torr
1 10-2 750.06x 10-5
102 1 0.75006
133.322 1.333 1
given
Pu
mp
ing
Sp
eed
(I/s
)
GP100 MK5 St 707
1
10
100
1000
0,001 0,01 0,1 1 10
H2
CO
Sorbed Quantity (Torr. l)nude with body
Sorption temperature: 25 °C Activation: 450 °C x 45' Sorption pressure: 3e-6 Torr
Volt
age
(V)
Cu
rren
t (A
)
GP100 MK5 (nude)
Temperature (°C)
Voltage (V) Current (A)
0
5
10
15
20
25
30
35
40
45
50
50 100 150 200 250 300 350 400 450 500 5500
0,5
1
1,5
2
2,5
3
3,5
4
4,5
5
W e s u p p o r t y o u r i n n o v a t i o n
HIGHLIGHTS
GP 200 MK5
The GP 200 MK5 pump uses a St 707 getter cartridge mounted on aheater structure based on a single heater element, and is available onCF100 (6”) flange.The flange is conveniently supplied with a custom-made, bakeableelectrical connector which combines power and thermocouple pins, forbest integration and minimum footprint.The pump sorption speed is at its maximum when mounted directly inthe vacuum system without a jacket.The pumping speed curves and the activation curves are shown in theenclosed graphs.
GP 200 MK5
ø 63
33
211
157
ø 152
saesgetters
Ordering Information
Base Flange with Connector and Heater
Base Flange with Connector, Heater and Body
Base Flange with Connector, Heater andWater Cooled Body
St 707 Getter Cartridge on Constantan Substrate
4H0236
4H0452
4H0453
4H0249
GP 200 MK5
GP 200 MK5 B
GP 200 MK5 W
C 200-MK5 St707
General features
High pumping speed for all active gases
Constant pumping speed in
HV and UHV pressure region
No low pressure limitation
(down to 10-12 Torr region)
Reversible pumping of hydrogen
and its isotopes
Possibility of operation at room
temperature after activation, without
power
Operation in the presence of high
magnetic fields
Oil free and vibration free ultra high
vacuum
Low weight
Applications
Improving ultimate vacuum in
combination with ion, diffusion,
cryogenetic or turbomolecular pumps
Surface analysis systems
Particle accelerators, synchrotron
radiation sources and related
equipment
Process pumps for vacuum devices
Portable vacuum instrumentation
Pumping, storing and releasing
hydrogen isotopes
Plasma machines
Hydrogen traps
Impurities removal in rare gas filled
devices
Dimensions in mm
2001 ©SAES Getters. Printed in Italy. All rights reserved. Sorb-Ac® is a trademark of SAES Getters.SAES Getters reserves the right to change or modify product specifications at any time without notice.
Lainate (Italy)
Avezzano (Italy)
Köln (Germany)
Moscow (Russia)
Paris (France)
Daventry (UK)
Nanjing (China)
Shanghai (China)
Tokyo (Japan)
Seoul (Korea)
Chin Chon (Korea)
Singapore
Hsin Chu (Taiwan)
Cleveland OH (USA)
Colorado Springs CO (USA)
San Luis Obispo CA (USA)
Sparks MD (USA)
D.VS.03.02
SAES Getters S.p.A.Group Headquarters:Viale Italia,7720020 Lainate (Milano), ItalyTel.: + 39 02 931 78 1Fax: + 39 02 931 78 320
www.saesgetters.com
SAES AdvancedTechnologies S.p.A.Nucleo Industriale:Via Diesel,167051 Avezzano (AQ), ItalyTel.: + 39 0863 495 1Fax: + 39 0863 267 43
Typical Pump Characteristics
PumpingSpeed (I/s)
Alloy Type St 707
Getter Alloy Mass (g) 170
Getter Surface (cm2) 4470
H2 900
CO 350
H2 Room Temperature 1700
CO Room Temperature 4.5
CO Total 1530
SorptionCapacity(Torr I)
Note: Pumping speed data refer to the initial values of the pumpwithout the pump body. CO capacity based on speed below 50 l/s.
Conversion Tablesought
Pa mbar Torr
1 Pa
1 mbar
1 Torr
1 10-2 750.06x 10-5
102 1 0.75006
133.322 1.333 1
given
GP200 MK5 St 707
1
10
100
1000
0,001 0,01 0,1 1 10 100
Pu
mp
ing
Sp
eed
(I/s
)
Sorbed Quantity (Torr. l)nude with body
Sorption temperature: 25 °C Activation: 450 °C x 45' Sorption pressure: 3e-6 Torr
H2
CO
Volt
age
(V)
Cu
rren
t (A
)
GP200 MK5 (nude)
Temperature (°C)
Voltage (V) Current (A)
0
10
20
30
40
50
60
70
50 100 150 200 250 300 350 400 450 500 5501
1,5
2
2,5
3
3,5
4
4,5
W e s u p p o r t y o u r i n n o v a t i o n
HIGHLIGHTS
GP 500 MK5
The GP 500 MK5 pump uses a St 707 getter cartridge mounted on aheater structure based on three heater elements, and is available onCF150 (8”) flange.The flange is conveniently supplied with a custom-made, bakeableelectrical connector which combines power and thermocouple pins, forbest integration and minimum footprint.The pump sorption speed is at its maximum when mounted directly inthe vacuum system without a jacket.The pumping speed curves and the activation curves are shown in theenclosed graphs.
GP 500 MK5
Ordering Information
Base Flange with Connector and Heater
Base Flange with Connector, Heater and Body
Base Flange with Connector, Heater andWater Cooled Body
St 707 Getter Cartridge on Constantan Substrate
4H0243
4H0454
4H0455
4H0248
GP 500 MK5
GP 500 MK5 B
GP 500 MK5 W
C 500-MK5 St707
ø 202
33
saesgetters
243
ø 98
188
General features
High pumping speed for all active gases
Constant pumping speed in
HV and UHV pressure region
No low pressure limitation
(down to 10-12 Torr region)
Reversible pumping of hydrogen
and its isotopes
Possibility of operation at room
temperature after activation, without
power
Operation in the presence of high
magnetic fields
Oil free and vibration free ultra high
vacuum
Low weight
Applications
Improving ultimate vacuum in
combination with ion, diffusion,
cryogenetic or turbomolecular pumps
Surface analysis systems
Particle accelerators, synchrotron
radiation sources and related
equipment
Process pumps for vacuum devices
Portable vacuum instrumentation
Pumping, storing and releasing
hydrogen isotopes
Plasma machines
Hydrogen traps
Impurities removal in rare gas filled
devices
Dimensions in mm
2001 ©SAES Getters. Printed in Italy. All rights reserved. Sorb-Ac® is a trademark of SAES Getters.SAES Getters reserves the right to change or modify product specifications at any time without notice.
Lainate (Italy)
Avezzano (Italy)
Köln (Germany)
Moscow (Russia)
Paris (France)
Daventry (UK)
Nanjing (China)
Shanghai (China)
Tokyo (Japan)
Seoul (Korea)
Chin Chon (Korea)
Singapore
Hsin Chu (Taiwan)
Cleveland OH (USA)
Colorado Springs CO (USA)
San Luis Obispo CA (USA)
Sparks MD (USA)
D.VS.03.02
SAES Getters S.p.A.Group Headquarters:Viale Italia,7720020 Lainate (Milano), ItalyTel.: + 39 02 931 78 1Fax: + 39 02 931 78 320
www.saesgetters.com
SAES AdvancedTechnologies S.p.A.Nucleo Industriale:Via Diesel,167051 Avezzano (AQ), ItalyTel.: + 39 0863 495 1Fax: + 39 0863 267 43
Typical Pump Characteristics
PumpingSpeed (I/s)
Alloy Type St 707
Getter Alloy Mass (g) 540
Getter Surface (cm2) 14290
H2 1900
CO 650
H2 Room Temperature 5400
CO Room Temperature 10
CO Total 4860
SorptionCapacity(Torr I)
Note: Pumping speed data refer to the initial values of the pumpwithout the pump body. CO capacity based on speed below 100 l/s.
Conversion Tablesought
Pa mbar Torr
1 Pa
1 mbar
1 Torr
1 10-2 750.06x 10-5
102 1 0.75006
133.322 1.333 1
given
GP500 MK5 St 707
1
10
100
1000
10000
0,01 0,1 1 10 100
Sorbed Quantity (Torr. l)nude with body
Pu
mp
ing
Sp
eed
(I/s
)
H2
CO
Sorption temperature: 25 °C Activation: 450 °C x 45' Sorption pressure: 3e-6 Torr
Volt
age
(V)
Cu
rren
t (A
)
GP500 MK5 (nude)
Temperature (°C)
Voltage (V) Current (A)
0
10
20
30
40
50
60
70
80
90
50 100 150 200 250 300 350 400 450 500 550 6003
4
5
6
7
8
9
10
11
12