Upload
earl-scott
View
216
Download
0
Embed Size (px)
DESCRIPTION
2000/9/23 JPS meeting in Niigata3 PbSc: Shish-Kebab sampling calorimeter PHENIX EM Calorimeter - PbSc (lead scintillator) and PbGl (lead glass) - Only Sector W0/W1 are used in this analysis. W1 W0 ~5m
Citation preview
2000/9/23 JPS meeting in Niigata 1
Measurement of single gamma and 0 with PHENIX EMCal (I)
H.Torii Kyoto Univ./RIKEN for the PHENIX Collaboration.
Sep/23/2000, JPS meeting in Niigata
2000/9/23 JPS meeting in Niigata 2
Physics Motivation
• Quark Gluon Plasma(QGP) search– One of the hard probe for
QGP is “Jet Quenching”– Jet Quenching.
• Quark energy loss in the QGP matter by gluon bremsstrahlung.
• Energy loss can be observed by measuring fragmented pi0
Xin-Nian WangPhys.Rev.C58 2321(1998)Au+Au s=200GeV (dE/dx=1GeV/c)
2000/9/23 JPS meeting in Niigata 3
PbSc: Shish-Kebab sampling calorimeter
PHENIX EM Calorimeter- PbSc (lead scintillator) and PbGl (lead glass) -
PbSc PbGlSize(cm x cm) 5.52 x 5.52 4.0 x 4.0
Depth(cm) 37.5 40Number of towers 15552 9216Sampling fraction ~ 20% 100%
cov. 0.7 0.7 cov. 90+45deg 45deg/ mod 0.011 0.008 / mod 0.011 0.008
X0 18 14.4Molière Radius ~ 3cm 3.68cm
Only Sector W0/W1 areused in this analysis.
W1
W0
~5m
2000/9/23 JPS meeting in Niigata 4
Data Set & Event Selection• Analyze Au+Au 130AGeV data sets
– Only for PbSc parts. Sector W0/W1– Aug/6 to Aug/18
• Event Selection– [1126k events]
BBC Z vertex < 40cm– [419k events]
-2.5nsec<(ZDC T0 – BBC T0 – [ZDC T0-BBC T0]) < 4.5nsec
BBC T0 < 13nsec– [371k events]
cm
Vertex Distribution
Time 0 Distribution
nsec
RMS 3nsec
2000/9/23 JPS meeting in Niigata 5
Geometrical Acceptance & Quality Assurance Check
• Geometrical Acceptance– Bottom 5 rows of W0
Sector are disabled• -0.376< <0.376• -0.636< <-0.213 (W0)• -0.190< <0.190 (W1)
• Quality Assurance Check– Disabled region
• 1.9 %
Normal Position Acceptance
W1
W0
2000/9/23 JPS meeting in Niigata 6
TOF PID cut
• TOF width 1.4nsec– Still dominated by tower by tower
calibration– Photon efficiency100%(>1GeV)– Background contamination 50%-0%
(Still large uncertainty in background contamination)
Background contaminationPhoton efficiency
Less background high E
Large deviation from simulation at slower TOF.
2000/9/23 JPS meeting in Niigata 7
Energy Calibration w/MIP• First energy scale is calibrated by cosmic
muon. 38MeV during construction• Measured MIP energy in W0/W1 sectors.
– June-July• W0: 266.11.3MeV• W1: 276.71.2MeV
– Aug• W0: 266.30.03MeV• W1: 257.10.02MeV
• Gain shift during between June/July and Aug.
– W0: 0.10.4%– W1: -7.00.4%
• Laser monitoring will be used soon in the analysis.
Au+Au 130AGeV PHENIX Preliminary
(Run 8713-10767)
Cosmic Muon
2000/9/23 JPS meeting in Niigata 8
Energy Calibration w/0 • Energy Correction
– Measured by PHENIX clustering algorithm• PHENIX clustering algorithm is energy sum of a
few core towers by considering shower profile. It’s to suppress overlapping effect
• Average energy obtained by PHENIX clustering algorithm is 93% of total shower.
– Energy correction of MIP into 280MeV• Correction is made for every 144 towers.• Path length by geometrical effect is already
accounted. 0 peak
(Asymmetry<0.8 , Pt>2.5GeV , TOF cut<2)– Before correction
• 123.5 1.9MeV =13.72.3MeV
– After correction• 135.91.8MeV
=12.42.1MeV
Absolute energy scale is roughly correctin 2%
Invariant Mass after correction
Invariant Mass before correction
GeV
GeV
2000/9/23 JPS meeting in Niigata 9
Table of Calibration• Energy
– Relative energy(every 144 towers) 2% (after <6% correction) – Absolute energy 2% (cosmic/hadron mip and pi0)
– Time dependence Studying by laser monitoring data • TOF
– Width 1.4nsec (mainly tower-by-tower calibration)
• Yield of photon– Geometrical acceptance -0.376< <0.376
-0.636< <-0.213 (W1) -0.190< <0.190 (W0)– Quality assurance check 1.9% disabled– TOF PID photon efficiency/background contamination
efficiency> 100%, Background 50-0%(Still large uncertainty in background contamination)
– Overlapping effect Studying
2000/9/23 JPS meeting in Niigata 10
EM Shower Energy Distribution• Different total energy
– TOF<2– Normalized at 0.5GeV– No efficiency correction
• No TOF efficiency nor background contamination correction
• No shower overlapping effect correction
– 4 slopes seem to be similar– Is there any centrality
dependence?Still Working on TOF
efficiency/background contamination and overlapping effect
Au+Au 130AGeVNo efficiency corr.PHENIX Preliminary
EM Shower Energy(GeV)A
rbitr
ary
GeV
Total Energy
2000/9/23 JPS meeting in Niigata 11
Summary• PHENIX successfully completed first physics run from June to early-
September in 2000.• PHENIX EM calorimeter works and has measured signals.• EM calorimeter calibration
– Energy, TOF are calibrated by laser, MIP peak of cosmic /charged hadron, an 0 mass
• Physics analysis is in progress.– EM shower energy distribution with different total energy.
• No Efficiency correction– TOF efficiency , background contamination are not corrected.– Shower overlapping effect is not corrected
• Slopes seem to be similar• We still working on TOF efficiency/background contamination and overlapping effects.
• We will investigate centrality dependence