DROK AC 80-260V Digital Multimeter
http://www.Droking.com
Parameter:
Display Format:
200071
Working voltage: AC 80~260V
Test voltage: AC 80~260V
Rated power: 0~22kW
Operating frequency: 45~65Hz
Measurement accuracy: 1.0 grade
Wiring Diagram:
Display Interface:
Voltage
Current
Power
Energy
Measuring range 80~260V
Display format: 80~260V
Measuring range: 0~100A
Display format: 0.00~99.99A
Measuring range: 0~22kW
Within 1kW: display 0.0~999.9W
1kW and above: display 1000`9999W
10kW and above: display 10.0~22.0kW
Measuring range: 0~9999kWh
Within 10kWH: display 0~9999WH
10kWH and above: display 10~9999kWH
Over 9999kWh: display 0
CT
Load
Load
CT
Key Functions:
Backlight Control
Short press to turn on/off backlight.Backlight on/off status automatically saved when power off.
Power/Energy Display Switch Short press to switch to display current power/cumulative energy consumption cumulative energy consumption.
Display status will be automatically saved when power off.
Energy Reset
Hold press for more than 3 seconds till the numbers of the energy display area flash, loose the key.
If short press , the energy data will be reset to 0 and exit reset mode.If over 10 seconds without any key action, the energy data won’t be reset to 0 and exit reset mode.
Power Alarm Hold press for more than 3 seconds till the numbers of the power display area flash, loose the key.
Note:
Please connect the wires strictly according to the wiring diagram.
The power of the load cannot exceed rated power.
Suitable for indoor use only, please do not use outdoor.
Not applicable for autotransformer, thyristor circuit or load.
Size:
57.5mm 38mm
37mm
67mm
57.5mm
62mm
67mm
52.5mm
65mm
53mm
24mm
62mmOverall:
Backside:
Opening:
Height:
Recommend product on Amazon:
100A/100mA AC Current Transformer
Any questions please contact us through Amazon:
Short press to +1 to the flashing lower digit.
Short press to switch the digit to be set. Alarm value cannot be set to exceed 2.5kW (factory default 2.5kW).
When finish setting, hold press for more than 3 seconds or over 10 seconds without any key actions, the data will be
automatically saved and exit the setting mode.
Power display area display currently set power alarm value, the lower digit start to flash.
Set Key