Upload
dangliem
View
218
Download
0
Embed Size (px)
Citation preview
B920 keypad operationYour security system provides quick access to functionsthrough the keypad menus. To access menus using a B920, press [MENU]. Press[PREV] or [NEXT] to scroll through the list of functionsprogrammed by your security company. To initiate thefunction shown on the display, press [ENTER] or pressthe corresponding number key, as indicated in the on-display instructions (for example, Press 2 for Statusmenu). To exit a specific menu and return to theprevious level, press [ESC]. To exit and return to idletext from any level of the menu structure, press andhold [ESC]. The keypad has a Shortcuts menu to quickly accessfunctions you use most. Your security companyprogrammed these Shortcuts for you. To accessShortcuts, press [MENU], and then press [6].
20
100 en | B920 keypad operation Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
B920 keys overview
Each B920 keypad has 10 number keys and sevenfunction keys. When pressed, keys turn on keypadbacklighting and emit the keypress tone (short beep).The function keys include programmable function keysand keys to initiate arming and bypassing with onekeypress.
B920 keys descriptionsMENUUse the [MENU] key to open the keypad’s Main menu.Press [MENU] + [6] to access the Shortcuts menu,which is the quickest way to access the functions youuse most. ALL, PART, and BYPASSUse the [ALL] key to turn your system All On. Use the[PART] key to turn your system Part On. Use the[BYPASS] key to access the menu to bypass points. ENTERUse the [ENTER] key to complete the entry of yourpasscode other numbers, or to answer Yes to a keypadrequest.
20.1
20.1.1
Control Panels B920 keypad operation | en 101
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
ESCThe [ESC] (Escape) key has two uses. First, use the[ESC] (Escape) key to exit from menus and functions.Also, use the key as a Backspace when you enter namesand numbers. HELPUse the [HELP] key to open the keypad’s on-displayHelp. Press [ESC] to exit help when you finish viewing. PREV and NEXTUse the [PREV] and [NEXT] keys to scroll throughmenus or menu selections. CMDUse the [CMD] key in combination with one or twonumber keys to perform select functions.
102 en | B920 keypad operation Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
B920 display overview
The B920 keypad uses words, numbers, and symbols toshow the status of the security system. When severalevents occur, the keypad shows each event in order ofpriority. The display shows two lines, 18 characters perline. The keypad has a bright two-line by 20-character liquidcrystal display (LCD).
20.2
Control Panels B920 keypad operation | en 103
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
B920 status LEDs overview
The status LEDs on keypads provide a quick visualreference for you to see how your system is operating.
Ready to arm: The green checkmark LED indicateswhether the system is ready to turn on (arm).
– ON Steady. All points are normal and the system isready to turn on.
– OFF. One or more points are faulted, and the systemis not ready to turn on.
On (armed): The red lock LED indicates whether thesystem is on (armed).
– ON Steady. All areas are on with no alarms.
– Flashing. All areas are armed, and there is an activealarm.
– OFF. One or more areas is off.
Trouble. The yellow caution LED lights when a troublecondition exists.
– ON Steady. There is a system, device, or pointtrouble.
– OFF. There are no system, device, or point troubles.
20.3
104 en | B920 keypad operation Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
GAS: The blue GAS LED indicates a gas alarm.
– Flashing. An area has a gas alarm. You should leavethe premises immediately when there is a gas alarm.
– OFF. A gas alarm does not exist within the keypad’sscope.
Power: The blue power plug LED indicates whether thecontrol panel has AC power.
– ON Steady. The AC (mains) power to the controlpanel is present.
– Flashing. AC (mains) power to the control panel isnot present and the control panel is operating fromthe battery.
– OFF. There is no power to the control panel.
Control Panels B920 keypad operation | en 105
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
B920 Menu treeThe B920 offers an easy-to-use menu tree structure. Toaccess the Menu tree, press [MENU]. Each menu optionhas a number. At each level, you can press the numberfor the desired menu, if you know it. Otherwise, use[PREV] or [NEXT] to review your options at that level,and then press [ENTER] when you see the desired menuoption. The Menu tree figure on the next page shows the Menustructure and the numbers associated for each menuoption.
21
106 en | B920 Menu tree Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
B920 Menu tree
* Your security company programmed the Shortcuts for you.
Press 1 forAll On menu.
Press 2 forPart On menu.
Press 3 forOff menu.
Press 4 forExtend Close time.
Press 5 forBypass menu.
Press 1 forAll On Delay.
Press 2 forAll On Instant.
Press 3 forAll On Select.
Press 1 forPart On Delay.
Press 2 forPart On Instant.
Press 3 forPart On Select.
Press 1 toTurn Off.
Press 2 toTurn Off Select.
Press 1 to View Area Status.
Press 2 toView Point Status.
Press 3 to Send Status Report.
Press 1 tochange passcode.
Press 2 to add user.
Press 3 toedit user.
Press 4 todelete user.
Press 1 toadjust brightness.
Press 2 to adjust volume.
Press 3 tosilence keytone.
Press 1 toset panel date.
Press 2 toset panel time.
Press 3 toshow date/time.
Press 1 tochange Watch mode.
Press 2 forDate/Time
Press 3 tochange schedule.
Press 4 forkeypad config.
Press 1 toview event
Press 2 toclear event
Press 3 toview log.
Press 1 forOn/Off menu.
Press 2 forStatus menu.
Press 3 forActions menu.
Press 4 forUsers menu.
Press 5 forSettings menu.
Press 6 forShortcuts menu.
Press 7 forEvents menu.
Press 1 toTurn Off.
Press 2 toTurn Off Select. Press 1 to
answer.
Press 2 forOriginate menu.
Press 3 tocall via phone.
Press 7 toview serv
Press 1 forWalk Test menu.
Press 4 totest notification.
Press 1 toconfigure
Press 2 to configure name.
Press 3 toconfigure level.
Press 4 toconfigure keyfob.
Press 5 to configure
*
Press 3 forTest menu.
Press 4 forRPS menu.
Press 5 togo to area.
Press 6 toupdate firmware.
Press 1 to reset sensors.
Press 2 tochange output.
Press 2 to Send Test report.
Press 3 todisplay revisions.
Control Panels B920 Menu tree | en 107
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
CommandsCommands resides outside of the Menu tree. You caninitiate a limited number of functions with the [CMD]key plus the one or two digit command. If you know the command number, press [CMD] andthen the one or two digit command.Review the available commands in the table on the nextpage
i
Notice!With B920 and B930 keypads, you can use [PREV] or[NEXT] to move through the list of commands, andpress [Enter] or [ENTER] when viewing the desiredcommand.
108 en | B920 Menu tree Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Function Command
All on CMD 1
All On, Instant CMD 1 1
Part On, Instant CMD 2
Part On CMD 3
Watch CMD 6
See Alarms CMD 4 0
Reset Sensors CMD 4 7
Extend Close CMD 5 1
Bypass CMD 0
Unbypass CMD 0 0
Control Panels B920 Menu tree | en 109
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
B920 On/Off menuUse the On/Off menu to turn areas All or Part On, toturn areas off, to extend closing time, or to bypasspoints. When you turn on (arm) your security system, there isan exit delay that gives you time to leave the areawithout sounding the burlary tone. When you enter asecurity system that is turned on (armed), there is anentry delay that gives you time to turn off (disarm) thesystem.
All On menu
Use the All On menu to turn areas All On. Turning anarea All On means to turn on all the points. All doorsand windows and all motion sensors, for example.
All OnTurning an area All On turns on all points in the area andprovides entry and exit delay. For example, you can turnon the area and leave through a door (within exit delaytime) without creating an alarm event. When you turnthe area All On, the display shows how many seconds ofexit delay time remain to exit the protected area. Leavebefore the exit delay time expires.
22
22.1
22.1.1
110 en | B920 On/Off menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Leaving after exit delay expires causes entry delay tostart. It may also cause an alarm on an interior device.Enter your passcode to turn off the system.
Control Panels B920 On/Off menu | en 111
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Turning areas All On:1. Press [MENU] to open the Main menu.2. Press [1] or [ENTER] to open the On/Off menu.3. Press [1] or [ENTER] to open the All On menu.4. Press [1] or [ENTER] to select All On Delay.5. Enter your passcode and press [ENTER]. The keypad
shows Exit Now! and sounds during the exit delay.6. Exit the area or enter your passcode to stop the
system from turning on. If you turn your system AllOn and don't exit, the system automatically switchesto Part On.
112 en | B920 On/Off menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
All On InstantTurning an area All On Instant turns on all points withno entry or exit delay. When areas are All On Instant,faulting any point (opening a door for example) createsan alarm event immediately. Turning areas All On Instant:1. Press [MENU] to open the Main menu.2. Press [1] or [ENTER] to open the On/Off menu.3. Press [1] or [ENTER] to open the All On menu.4. Use [NEXT] to go to the All On Instant option, and
press [ENTER], or simply press [2]. The keypadshows All On.
5. To turn off the security system, enter your passcodeand press [ENTER].
22.1.2
Control Panels B920 On/Off menu | en 113
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Select Area (All On menu)Use All On Select to choose individual areas to turn AllOn or All On Instant. You choose areas from a list of theareas in which you have authority. Turning on a specific area:1. Press [MENU] to open the Main menu.2. Press [1] or [ENTER] to open the On/Off menu.3. Press [1] or [ENTER] to open the All On menu.4. Use [NEXT] to go to the All On Select menu, and
press [ENTER], or simply press [3].5. Use [NEXT] and [ENTER] to select either the On
Instant or On Delay option. The keypad respondsbased upon your selection.
22.1.3
114 en | B920 On/Off menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Part On menu
Use the Part On menu to turn areas Part On. Turning anarea Part On means to turn on only some of the points,and thus part of the system. For example, your securitycompany might configure your system so that when youuse the Part On function, only the exterior doors andwindows turn on, whereas interior motion sensors donot turn on.
Part OnTurning an area Part On turns on some points, or part ofthe system, in the area and provides entry and exitdelay. For example, you can turn on the area and leavethrough a door (within exit delay time) without creatingan alarm event. Turning the perimeter on with an exit delay:1. Press [MENU] to open the Main menu.2. Press [1] or [ENTER] to open the On/Off menu.3. Use [NEXT] to go to the Part On option, and press
[ENTER], or simply press [2].4. Press [1] or [ENTER] to open the Part On Delay
option. The keypad shows Part On Dly.5. To turn off the system, enter your passcode and
press [ENTER].
22.2
22.2.1
Control Panels B920 On/Off menu | en 115
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Part On InstantTurning an area Part On turns on some points, or part ofthe system, in the area with no entry or exit delay. Whenthe area is Part On Instant, faulting a Part On point(opening a door for example) creates an alarm eventimmediately. Turning the system Part On without delay:1. Press [MENU] to open the Main menu.2. Press [1] or [ENTER] to open the On/Off menu.3. Use [NEXT] to go to the Part On option, and press
[ENTER], or simply press [2].4. Use [NEXT] to go to the Part On Instant option, and
press [ENTER], or press [2].5. Enter your passcode and press [ENTER]. The keypad
shows Part On Inst.6. To turn off the system, enter your passcode and
press [ENTER].
22.2.2
116 en | B920 On/Off menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Select Area (Part On menu)Use Part On Select to choose individual areas to turnPart On or Part On Instant. You choose areas from a listof the areas in which you have authority. Turning individual areas Part On:1. Press [MENU] to open the Main menu.2. Press [1] or [ENTER] to open the On/Off menu.3. Use [NEXT] to go to the Part On option, and press
[ENTER], or simply press [2].4. Use [NEXT] to go to the menu Part On Select menu,
and press [ENTER], or press [3].5. Use [NEXT] and [ENTER]to select either the On
Instant or On Delay option. The keypad respondsbased upon your selection.
22.2.3
Control Panels B920 On/Off menu | en 117
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Off menu
You can turn areas off simply by entering your passcodeor by using the Off menu. With either option, you turnoff all areas in which you have authority. You must enter your personal passcode and enterthrough a designated entry door to prevent an instantalarm condition. Opening the door starts entry delaytime and the keypad emits a pulsing “beep” tone toremind you to turn the system off. Enter your passcodebefore the entry delay time expires. If you enter through the wrong door or fail to turn off(disarm) before the entry delay time expires, an alarmoccurs. If this happens, silence the alarm (by enteringyour personal passcode and pressing [ENTER]) and callyour security company to notify them that you do nothave an emergency situation. Turning off the security system (disarm) with yourpasscode:1. Enter your personal passcode.2. Press [ENTER] within 8 sec of entering your
passcode. The display returns to idle text.
22.3
118 en | B920 On/Off menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Turn OffYou can use the Turn Off menu to turn off all areas inwhich you have authority. Turning off areas:1. Press [MENU] to open the Main menu.2. Press [1] or [ENTER] to open the On/Off menu.3. Use [NEXT] to go to the menu Off menu, and press
[ENTER], or simply press [3].4. Press [1] or [ENTER] to open the Off menu.5. Enter your passcode and press [ENTER]. The display
returns to idle text.
Turn Off SelectUse Turn Off Select to choose individual areas to turnoff. You choose areas from a list of the areas in whichyou have authority. Turning off a specific area:1. Press [MENU] to open the Main menu.2. Press [1] or [ENTER] to open the On/Off menu.3. Use [NEXT] to go to the menu Off menu, and press
[ENTER], or simply press [3].4. Use [NEXT] to go to the menu Turn Off Select menu,
and p[ENTER], or simply press [2].5. Use [NEXT] and [ENTER] to select an area.6. Press [ENTER] to turn off your selected area.
22.3.1
22.3.2
Control Panels B920 On/Off menu | en 119
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Extend Closing
Your security company might program your system toexpect you to turn on (arm) within a closing window. Aclosing window is a duration of time programmed byyour security company. Your security company sets afixed length of time for the closing window. Additionally,your security company might program your system toautomatically turn on (arm) at the end of the window. Use the Extend Close Time option when you need tostay later than the scheduled close time. If you do notextend the Close Time and do not turn the system onbefore the scheduled time, the system creates a Late toClose event. At the beginning of the closing window, the keypadbeeps and shows Please Close Now to remind you toturn on (arm) your system. It remains in the display untilyou turn on the system, the close window ends, or youextend closing. Alarm or trouble messages replace thismessage in the event of an alarm or trouble condition. Ifthe alarm or trouble condition clears before the end ofthe close window Please Close Now returns to thekeypad display.
22.4
120 en | B920 On/Off menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Pressing [ESC] silences the beep and clears themessage for 10 minutes. If you have not turned yoursystem on (armed) or extended closing, the Please CloseNow message and beep reappear after 10 minutes. Toextend the window, enter the new time at which youwould like the reminder tone to begin. This time is thenew beginning of the closing window. When you hear the warning, you can:– Leave before the end of the closing window by
pressing [ESC] to silence the signal, turning on thesystem, and leaving.
– Stay past the scheduled end of the closing window,by using this function to extend the closing window.
To extend closing:1. Press [MENU] to open the Main menu.2. Press [1] or [ENTER] to open the On/Off menu.3. Use [NEXT] to go to the Extend Closing menu, and
press [ENTER], or simply press [4].4. Enter your passcode and press [ENTER].
i
Notice!You cannot extend the window across the midnightboundary. The system cannot arm if points are off-nor-mal.
Control Panels B920 On/Off menu | en 121
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Bypass menu
Use the Bypass menu to temporarily take points out ofthe security system, and enter them back into thesystem. Bypassed points do not create alarm or troubleevents, do not detect intruders, and cannot send anyreports. For example, to leave a window open and turnthe system on, you bypass the window point and thenturn the system on.
BypassYou can bypass points when an area is turned off(disarmed). Points remain bypassed until you unbypassthem or some points return when the area is turned off(disarmed). Use point bypassing with discretion:bypassing a point reduces the level of security. Bypassing a point:1. Press [MENU] to open the Main menu.2. Press [1] or [ENTER] to open the On/Off menu.3. Use [NEXT] to go to the Bypass menu, and press
[ENTER], or simply press [5].4. Press [1] or [ENTER] to open the Bypass Points
menu.5. Select a point to bypass.6. Press [ESC] to exit the menu.
22.5
22.5.1
122 en | B920 On/Off menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
UnbypassUnbypassing a point returns a bypassed point to thesecurity system so that it can once again respond totrouble and alarm conditions. Unbypassing a point:1. Press [MENU] to open the Main menu.2. Press [1] or [ENTER] to open the On/Off menu.3. Use [NEXT] to go to the Bypass menu, and press
[ENTER], or simply press [5].4. Use [NEXT] to go to the Unbypass menu, and press
[ENTER], or simply press [2].5. Enter your passcode and press [ENTER].6. Select a point to bypass.7. Press [ESC] to exit the menu.
22.5.2
Control Panels B920 On/Off menu | en 123
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
B920 Status menuUse the Status menu to see area or point status, or tosend a status report.
View Area Status
Area Status shows the on/off status for areas in whichyou have authority. Viewing area status:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Status menu option, and
press [ENTER], or simply press [2].3. Press [1] or [ENTER] to open the View Area Status
menu.4. Enter your passcode and press [ENTER]. The display
shows the status of each area. For example A1: Off.5. Press [ESC] to exit the menu.
23
23.1
124 en | B920 Status menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
View Point Status
The View Point Status feature shows the status (normal,open, or short) for all points in the areas in which youhave authority. Viewing point status:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Status menu option, and
press [ENTER], or simply press [2].3. Use [NEXT] to go to the View Point Status menu
option, and press [ENTER], or simply press [2].4. The display shows the number of points in the
system. Use [PREV] or [NEXT] to scroll through thelist of points and each point’s status.
5. Press [ESC] to exit the menu.
23.2
Control Panels B920 Status menu | en 125
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Send Status Report
The Send Status Report feature sends a completesystem status report to your security monitoringcompany. Status reports can alert them to potentialproblems. Sending a status report:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Status menu option, and
press [ENTER], or simply press [2].3. Use [NEXT] to go to the Send Status Report menu
option, and press [ENTER], or simply press [3].4. Enter your passcode and press [ENTER]. The control
panel sends a status report to your securitycompany.
23.3
126 en | B920 Status menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
B920 Actions menuUse the Actions menu to reset sensors, change outputs,see the test menu, see the RPS menu, go to an area,update system firmware, or to view service bypassedpoints.
Reset
Detection devices, such as smoke detectors and shocksensors, might require a reset action before they returnto normal operation. This function momentarily removespower from these devices to reset them. Resetting sensors:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Actions menu option, and
press [ENTER], or simply press [3].3. Press [1] or [ENTER] to reset the sensors with the
Reset option.4. Enter your passcode and press [ENTER]. The display
shows Sensors resetting for approximately 3 secondsand then goes blank before returning to idledisarmed text.
If you enter this function and the detector or sensorresets momentarily, but then returns to a faultedcondition, the conditions causing the activation may still
24
24.1
Control Panels B920 Actions menu | en 127
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
be present or the detector may be faulty. Check to becertain that there is no smoke, fire, or other dangerpresent. If you cannot reset the detector or sensor, contact yoursecurity company.
128 en | B920 Actions menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Outputs
Your security company programs outputs for automaticcontrol and/or keypad control of devices such aspremises lighting or entry gates. An output is a devicethat is controlled by the security system. Contact yoursecurity company for further information regarding theuse of outputs in your security system. Use this function to select outputs to turn on or off.Outputs on your security system can control othersystems, lighting for example. Your security system is not UL listed for access control. Turning outputs on and off:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Actions menu option, and
press [ENTER], or simply press [3].3. Use [NEXT] to go to the Outputs menu option, and
press [ENTER], or simply press [2].4. Enter your passcode and press [ENTER].5. Use [NEXT] to select the desired output value, or
use the number keys to enter the value.6. Press [ENTER]. The current state of the output
shows.7. Use [ENTER] to toggle between Off and On.8. Press [ESC] to exit the menu.
24.2
Control Panels B920 Actions menu | en 129
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Test
Use the Test menu to walk test your system, send testreports, or to review system revision information on thekeypad display.
Walk TestA walk test allows you to test the sensors, keypads,sounders, and other devices in your system withoutcreating alarm events. You can review untested pointsat the keypad to help pinpoint any problems. You cannot turn on the security system while in the walktest mode. Also, the security system does not createalarm events for points included in the walk test. Pointsnot included create alarm events. For example, faultinga fire point during an intrusion walk test creates a firealarm event. Beginning the walk test activates the burglary tone for 2seconds. A battery test also begins. A successful batterytest ends in four minutes (the walk test continues). Ifthe security system determines there is a low battery, itgenerates a low battery event and continues the test. Ifthe battery is determined to be very low, the systemcreates a missing battery event and ends the batterytest immediately.
24.3
24.3.1
130 en | B920 Actions menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
To test individual detection devices, simply activatesensors and open protected doors and windows one-at-a-time. As you fault each detection device, the keypadfrom which you initiated the test emits a brief tone, andfor 60 seconds the display indicates that the point wastested. The tone and display verify that each detectiondevice is working properly. Keypads within the area’sscope from which you did not initiate the walk testshow Walk test in progress during the testing. Performing a walk test:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Actions menu option, and
press [ENTER], or simply press [3].3. Use [NEXT] to go to the Test menu option, and press
[ENTER], or simply press [3].4. Press [1] or [ENTER] to open the Walk Test menu.5. Enter your passcode and press [ENTER].6. Use [NEXT] to go to the desired walk test, and press
[ENTER], or simply press the number key for thedesired walk test: [1] for Fire, [2] for Intrusion, [3]for Service, or [4] for Invisible.
7. Press [ENTER] to view the points.8. Use [NEXT] to toggle through your desired point and
view the status of that point.9. Press [ESC] to exit the menu.
Control Panels B920 Actions menu | en 131
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Automatic terminationThe Walk Test automatically ends after 20 minutes of notest activity. The keypad sounds during the last 5minutes of the test.
132 en | B920 Actions menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Send Test ReportThis function tests the communication link betweenyour security system and your security company. It is animportant part of maintaining a high level of security foryour property. Sending a test report:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Actions menu option, and
press [ENTER], or simply press [3].3. Use [NEXT] to go to the Test menu option, and press
[ENTER], or simply press [3].4. Use [NEXT] to go to the Send Test Report menu
option, and press [ENTER], or simply press [2].5. Enter your passcode and press [ENTER]. The system
sends a test report.6. Press [ESC] to exit the menu
24.3.2
Control Panels B920 Actions menu | en 133
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
RevisionsUse this function to view the current reversion of yourcontrol panel firmware. Viewing the current revision of your system (controlpanel):1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Actions menu option, and
press [ENTER], or simply press [3].3. Use [NEXT] to go to the Test menu option, and press
[ENTER], or simply press [3].4. Use [NEXT] to go to the Revisions menu option, and
press [ENTER], or simply press [3]. The currentcontrol panel revision information shows on thedisplay.
5. Press [ESC] to exit the menu.
24.3.3
134 en | B920 Actions menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Notification TestUse this menu to test the security system’s ability tosend personal notification messages to the destinationpath designated by your security company. Testing notifications:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Actions menu option, and
press [ENTER], or simply press [3].3. Use [NEXT] to go to the Test menu option, and
[ENTER], or simply press [3].4. Use [NEXT] to go to the Notification Test Report
option, and press [ENTER], or simply press [4]. Thekeypad shows the first destination.
5. Use [NEXT] to go to the desired destination, andthen press [ENTER]. The control panel sends a testnotification, and then returns to idle text.
24.3.4
Control Panels B920 Actions menu | en 135
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
RPS
Use the RPS menu for connection to RemoteProgramming Software (RPS). Your security companyuses RPS to configure and service your security system.RPS is intended for use by professional or licensedinstallers only.
AnswerUse the Answer option to answer the phone (pick upthe phone line) to connect to RPS. Using the Answer menu option to answer an incomingcall from RPS:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Actions menu option, and
press [ENTER], or simply press [3].3. Use [NEXT] to go to the RPS menu option, and press
[ENTER], or simply press [4].4. Press [1] or [ENTER] to reset the sensors with the
Answer option.5. Enter your passcode and press [ENTER]. The keypad
shows RPS is connecting…. and then returns to idletext.
24.4
24.4.1
136 en | B920 Actions menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Network OriginateUse this function to originate an RPS session using an IP(internet) connection. Connecting to RPS using an internet connection:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Actions menu option, and
press [ENTER], or simply press [3].3. Use [NEXT] to go to the RPS menu option, and press
[ENTER], or simply press [4].4. Use [NEXT] to go to the Network Originate menu
option, and press [ENTER], or simply press [2].5. Enter your passcode and press [ENTER].6. To use the programmed port number, press [1] or
press [ENTER]. The connection progress begins.7. If you wish to change the port number before
connecting, press [NEXT] and then [ENTER], orsimply press [2]. The [ESC] key acts as a backspacekey. Press [ESC] to delete the characters, and thenenter the new characters. Press [ENTER]. Theconnection process begins.
24.4.2
Control Panels B920 Actions menu | en 137
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Call Via PhoneUse this function to call RPS using the phone line. Connecting to RPS via the phone line:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Actions menu option, and
press [ENTER], or simply press [3].3. Use [NEXT] to go to the RPS menu option, and press
[ENTER], or simply press [4].4. Use [NEXT] to go to the Call Via Phone menu option,
and press [ENTER], or simply press [3].5. Enter your passcode and press [ENTER]. The
connection process begins.
24.4.3
138 en | B920 Actions menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Go to Area
With the Go to Area function you can perform tasks inan area other than the one you’re in without having tophysically go to that area. For example, using thekeypad in the office area, you could 'go' to the loadingarea. You select the area from a list of areas in whichyou have authority. Once you 'go’ to an area, you can perform tasks youhave authority for in that area. To 'leave' an area press[ESC]. Using Go to Area:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Actions menu option, and
press [ENTER], or simply press [3].3. Use [NEXT] to go to the Go to Area menu option,
and press [ENTER], or simply press [5].4. Enter your passcode and press [ENTER].5. Use [NEXT] to go to the area you wish to enter, and
then press [ENTER].
24.5
Control Panels B920 Actions menu | en 139
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Firmware
Your security company might have configured yoursecurity system to require your authorization beforesystem firmware can be updated. Use this action toprovide authorization at the request of your securitycompany. Local authorization is required for UL listedsystems. Authorizing a firmware update:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Actions menu option, and
press [ENTER], or simply press [3].3. Use [NEXT] to go to the Firmware menu option, and
[ENTER], or simply press [6].4. Enter your passcode and press [ENTER].
24.6
140 en | B920 Actions menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Service Bypass
To facilitate system maintenance for service personnel,your security system comes with a special point bypassoption to remove any point from service. Bypassedpoints are not protected. Use this menu to viewbypassed points. Viewing points in Service Bypass:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Actions menu option, and
press [ENTER], or simply press [3].3. Use [NEXT] to go to the Service Bypass menu
option, and press [ENTER], or simply press [6].4. Enter your passcode and press [ENTER]. The keypad
shows any points in service bypass.
24.7
Control Panels B920 Actions menu | en 141
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
B920 Users menuUse the Users menu to change your own passcode, addnew users, edit existing users, or to delete users.
Change Passcode
Use the Change Passcode function to change yourpersonal passcode.Before you begin, consider the following:– Choose a new passcode three to six digits long. If
you choose a passcode with the same digit inconsecutive order (for example “33” in 334697),take care when entering it.
– To avoid conflicting with other passcodes andduress codes, your security system does not let youchange to existing passcodes or passcodes that arewithin plus or minus 2 of an existing passcode. Forexample, if 1234 were an existing code, yoursecurity system would not let you change your codeto 1232, 1233, 1234, 1235, or 1236.
25
25.1
142 en | B920 Users menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Changing your passcode:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go the Users menu option, and press
[ENTER], or simply press [4].3. Press [1] or [ENTER] to open the Change Passcode
option.4. Enter your current passcode and press [ENTER].5. Enter your new passcode and press [ENTER].6. Enter your new passcode again and press [ENTER].
The keypad shows Passcode changed and thenreturns to the Change Passcode option.
7. Press [ESC] to exit the menu.
Control Panels B920 Users menu | en 143
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Add User
Use the Add User function to add a passcode to yoursecurity system. Before you add the user, you need toknow which user numbers are available, the authoritylevel you want to assign to the new passcode, and theareas in which it will be valid. The two-digit user numbers identify users in reportstransmitted from your security system. The authoritylevel determines what system functions the passcodecan access. The area number identifies which parts ofyour security system the passcode can access. Contactyour security company if you don’t know what usernumbers, authority levels, or areas are available.
25.2
144 en | B920 Users menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Before you begin:– Do not try to add passcodes without knowing the
available user numbers. These are two-digitnumbers, not to be confused with passcodes, thatidentify users at your security company.
– Choose a new passcode three to six digits long. Ifyou choose a passcode with the same digit inconsecutive order (for example “33” in 334697),take care when entering it.
– To avoid conflicting with other passcodes andduress codes, your security system does not let youadd passcodes that are within plus or minus 2 of anexisting passcode. For example, if 1234 were anexisting code, your system would not let you changeyour code to 1232, 1233, 1235, or 1236.
– Choose an authority level for each area. Leaving theauthority level for an area blank by pressing [Enter]or [ENTER] without making an entry, denies thepasscode access to that area.
Control Panels B920 Users menu | en 145
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Adding a user:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go the Users menu option, and press
[ENTER], or simply press [4].3. Use [NEXT] to go to the Add User menu option, and
press [ENTER], or simply press [2].4. Enter your passcode and press [ENTER].5. Enter the number (1 – 50) for the user you wish to
add, and press [ENTER]. Configuring the user’s passcode:1. Press [1] or [ENTER] to open the Configure
Passcode menu.2. Press [ENTER] to configure the user’s passcode.3. Enter the user’s passcode and press [ENTER].4. Enter the passcode again and press [ENTER]. The
keypad shows Passcode changed and then returns tothe previous menu.
146 en | B920 Users menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Configuring the user’s name:1. Use [NEXT] to go to the Configure Name option, and
press [ENTER], or simply press [2].2. Press [ENTER] to configure the user’s name.3. The [ESC] key acts as a backspace key. Press [ESC]
to delete the characters. Press a number keyrepeatedly to scroll through the number and lettersshown on the key. To enter a space, press [0][0]. Toenter a space, press [0][0]. To capitalize a letter,press [CMD] before you enter the letter. For capslock, press [CMD][CMD]. To remove caps lock,press [CMD][CMD][CMD].
4. Press [ENTER] to save the new name. The keypadreturns to the previous menu.
Configuring the user’s level:1. Use [NEXT] to go to the Configure Level option, and
press [ENTER], or simply press [3].2. Press [ENTER] to change the default authority level
for area 1.3. Enter the authority level number (1 – 14) you wish
to apply to the user and press [ENTER]. The keypadshows Level configured and returns to the previousmenu.
4. If your security system has more than one area, use[NEXT] and the previous two steps to set the levelsfor the additional areas.
Control Panels B920 Users menu | en 147
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Configuring a RADION keyfob* or an InovonicsTransmitter for the user:1. Use [NEXT] to go to the Configure Keyfob option,
and press [ENTER], or simply press [4].2. Press [ENTER] to continue.3. To manually enter the RFID, if desired, press [1] or
[ENTER] to open the RFID option. Otherwise, thekeypad automatically learns the RFID into thesecurity system when you add a RADION keyfob* oran Inovonics Transmitter.
4. Press [ENTER] to continue.5. Enter the RFID.6. Press [ENTER] to save the RFID and return to the
previous menu.7. Use [NEXT] to go to the Add a Keyfob option, and
press [ENTER] or simply press [2].8. Press [ENTER] to continue.9. On a RADION keyfob*, press any button on the
keyfob. On an Inovonics Transmitter, open thetransmitter and press the RESET button, per themanufacturer’s instructions. The keypad showsKeyfob enrolled and returns to the previous menu.
10. If you need to replace the keyfob or transmitter youjust added (for example, you accidentally added thewrong one), use [NEXT] to go to the Replace aKeyfob option, and press [ENTER],or simply press[3], and then follow the previous step.
148 en | B920 Users menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
11. To remove the added keyfob or transmitter, use[NEXT] to go to the Remove a Keyfob option, andpress [ENTER] or simply press [4].
12. Press [ESC] to exit the menu.*Not applicable to UL listed systems. Selecting a keypad display language for the user:1. Use [NEXT] to go to the Configure Keyfob option,
and press [ENTER], or simply press [4].2. Press [ENTER] to continue.3. Press [ENTER] to change the language. The keypad
shows Language configured, and then returns to theprevious menu.
Control Panels B920 Users menu | en 149
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Edit User
Use the Edit User function to edit a user of your securitysystem. You need to know the user number for the useryou want to edit. Editing an existing user:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go the Users menu option, and press
[ENTER], or simply press [4].3. Use [NEXT] to go to the Edit User menu option, and
press [ENTER], or simply press [3].4. Enter your passcode and press [ENTER].5. Enter the number (1 – 50) for the user you wish to
edit, and press [ENTER].6. The keypad shows the name for the user number
you entered. Press [ENTER]. Configuring the user’s passcode:1. Press [1] or [ENTER] to open the Configure
Passcode menu.2. Press [ENTER] to configure the user’s passcode.3. Enter the user’s passcode and press [ENTER].4. Enter the passcode again and press [ENTER]. The
keypad shows Passcode changed and then returns tothe previous menu.
Configuring the user’s name:
25.3
150 en | B920 Users menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
1. Use [NEXT] to go to the Configure Name option, andpress [ENTER], or simply press [2].
2. Press [ENTER] to configure the user’s name.3. The [ESC] key acts as a backspace key. Press [ESC]
to delete the characters. Press a number keyrepeatedly to scroll through the number and lettersshown on the key. To enter a space, press [0][0]. Toenter a space, press [0][0]. To capitalize a letter,press [CMD] before you enter the letter. For capslock, press [CMD][CMD]. To remove caps lock,press [CMD][CMD][CMD].
4. Press [ENTER] to save the new name. The keypadreturns to the previous menu.
Configuring the user’s level:1. Use [NEXT] to go to the Configure Level option, and
press [ENTER], or simply press [3].2. Press [ENTER] to change the default authority level
for area 1.3. Enter the authority level number (1 – 14) you wish
to apply to the user and press [ENTER]. The keypadshows Level configured and returns to the previousmenu.
4. If your security system has more than one area, use[NEXT] and the previous two steps to set the levelsfor the additional areas.
Control Panels B920 Users menu | en 151
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Configuring a RADION keyfob* or an InovonicsTransmitter for the user:1. Use [NEXT] to go to the Configure Keyfob option,
and press [ENTER], or simply press [4].2. Press [ENTER] to continue.3. To manually enter the RFID, if desired, press [1] or
[ENTER] to open the RFID option. Otherwise, thekeypad automatically learns the RFID into thesecurity system when you add a RADION keyfob* oran Inovonics Transmitter.
4. Press [ENTER] to continue.5. Enter the RFID.6. Press [ENTER] to save the RFID and return to the
previous menu.7. Use [NEXT] to go to the Add a Keyfob option, and
press [ENTER] or simply press [2].8. Press [ENTER] to continue.9. On a RADION keyfob*, press any button on the
keyfob. On an Inovonics Transmitter, open thetransmitter and press the RESET button, per themanufacturer’s instructions. The keypad showsKeyfob enrolled and returns to the previous menu.
10. If you need to replace the keyfob or transmitter youjust added (for example, you accidentally added thewrong one), use [NEXT] to go to the Replace aKeyfob option, and press [ENTER],or simply press[3], and then follow the previous step.
152 en | B920 Users menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
11. To remove the added keyfob or transmitter, use[NEXT] to go to the Remove a Keyfob option, andpress [ENTER] or simply press [4].
12. Press [ESC] to exit the menu.*Not applicable to UL listed systems. Selecting a keypad display language for the user:1. Use [NEXT] to go to the Configure Keyfob option,
and press [ENTER], or simply press [4].2. Press [ENTER] to continue.3. Press [ENTER] to change the language. The keypad
shows Language configured, and then returns to theprevious menu.
Control Panels B920 Users menu | en 153
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Delete User
Use the Delete User function to delete a user. Use this function to remove users from the system. Alluser data (name, passcode, keyfob) is deleted andcannot be recovered. Use Edit User if you only wish toremove a user's authority (disable the user), but retainthe user’s data. You need to know the user number forthe passcode you want to delete. The user numbersidentify users in reports transmitted from your system. Deleting a user:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go the Users menu option, and press
[ENTER], or simply press [4].3. Use [NEXT] to go to the Delete User menu option,
and press [ENTER], or simply press [4].4. Enter your passcode and press [ENTER].5. Enter the number for the user you wish to delete,
and press [ENTER].6. Press [ENTER] to continue.7. Press [ENTER] to confirm you wish to delete the
selected user. The keypad shows User ## deleted,and then returns to the previous menu.
8. Press [ESC] to exit the menu.
25.4
154 en | B920 Users menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
B920 Settings menuUse the Settings menu to turn Watch mode on or off,set the system date and time, view and changeschedules, set keypad brightness and volume, and showthe time in the keypad display.
Watch Mode
You can use Watch Mode to monitor select points withthe security system turned off. Each time points arefaulted (door or window is opened), the keypad chimesonce and shows the point text for 60 seconds. Thecontrol panel does not generate alarms in this modeexcept 24-hour alarms (fire, panic, etc.). Use this function in residential systems to monitorentries or exits in your home. In commercial systems itcan serve as a door chime to alert you when a customeror delivery person enters your business.
26
26.1
Control Panels B920 Settings menu | en 155
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Entering and exiting Watch Mode:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Settings menu option, and
press [ENTER], or simply press [5].3. Press [1] or [ENTER] to open the Watch Mode
option.4. Enter your passcode and press [ENTER].5. Press [ENTER] to turn Watch Mode on if it is off, or
off if it is on. The keypad display indicates that youenabled or disabled Watch Mode successfully.
6. Press [ESC] to exit the menu.
156 en | B920 Settings menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Date/Time
Your security system must have the correct time anddate for scheduled events to occur at the correct times.Use the Date/Time function to set both the time anddate. The security system uses a 12-hour AM/PM format. If your security system is configured for automatic date/time updates, the update might overwrite your changes. Setting the date and time:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Settings menu option, and
press [ENTER], or simply press [5].3. Use [NEXT] to go to the Date/Time menu option,
and press [ENTER], or simply press [2].4. Enter your passcode and press [ENTER].5. Press [1] or [ENTER] to set the control panel’s date.6. Enter the new date in MM/DD/YY format. If you
make a mistake, the [ESC] key acts as a backspacekey. Press [ESC] to delete the characters and thenenter the new numbers.
7. Press [ENTER]. The keypad shows Change completeand then returns to the previous menu.
8. Use [NEXT] to go to the option to change the time,and press [ENTER], or simply press [2].
26.2
Control Panels B920 Settings menu | en 157
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
9. Enter the new time in HH:MM format. If you make amistake, the [ESC] key acts as a backspace key.Press [ESC] to delete the characters and then enterthe new numbers.
10. Press [ENTER] to save the time and to go to the AMor PM selection option.
11. Press [ENTER] to select AM, or press [NEXT] andthen [ENTER] to select PM. The keypad showsChange complete and then returns to the previousmenu.
12. Press [ESC] to exit the menu.
158 en | B920 Settings menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Schedule (SKEDs)
A SKED is a function programmed to be performedautomatically at a scheduled time by your securitysystem. You can change the scheduled time for SKEDs,disable a SKED to prevent it from automaticallyhappening, or restart a previously disabled SKED.Contact your security company to determine whatSKEDs they programmed for your system. Selecting a SKED to change:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Settings menu option, and
press [ENTER], or simply press [5].3. Use [NEXT] to go to the Schedule menu option, and
[ENTER], or simply press [3].4. Enter your passcode and press [ENTER].5. Use [PREV] or [NEXT] to scroll through the list of
SKEDs. The keypad indicates whether a SKED isenabled, disabled, or not yet programmed.
6. With the SKED you wish to enable showing, press[ENTER].
7. Continue to Enabling a disabled SKED or Disabling aenabled SKED.
26.3
Control Panels B920 Settings menu | en 159
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Enabling a disabled SKED:1. With the SKED you wish to enable showing, press
[ENTER].2. Press [ENTER] to continue.3. Enter the new time in HH:MM format. If you make a
mistake the [ESC] key acts as a backspace key.Press [ESC] to delete the characters and then enterthe new numbers.
4. Press [ENTER] to save the time and choose AM orPM.
5. Press [ENTER] to select AM, or press [NEXT] andthen [ENTER] to select PM. The keypad showsSchedule update complete and then returns to theprevious menu.
6. Press [ESC] to exit the menu. Disabling an enabled SKED:1. With the SKED you wish to enable showing, press
[ENTER].2. Press [ENTER].to continue disable it. The keypad
display indicates that the SKED is disabled.3. Press [ESC] to exit the menu.
160 en | B920 Settings menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Keypad
Use the Keypad menu to adjust the brightness of thekeypad display, the keypress volume, and enable ordisable the keypress tone.
BrightnessUse the Brightness function to adjust the brightnesslevel for the keypad display. Adjusting the keypad display brightness:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Settings menu option, and
press [ENTER], or simply press [5].3. Use [NEXT] to go to the Keypad menu option, and
press [ENTER], or simply press [4].4. Press [1] or [ENTER] to adjust the brightness.5. Press [PREV] or [NEXT] to adjust the brightness
level. The changes apply immediately.6. Press [ESC] to exit the menu.
26.4
26.4.1
Control Panels B920 Settings menu | en 161
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
VolumeUse the Volume function to adjust the keypress volumelevel for the keypad. Adjusting the keypress volume:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Settings menu option, and
press [ENTER], or simply press [5].3. Use [NEXT] to go to the Keypad menu option, and
press [ENTER], or simply press [4].4. Use [NEXT] to go to the Volume menu option, and
press [ENTER], or simply press [2].5. Press [PREV] or [NEXT] to adjust the volume level.
The changes apply immediately.6. Press [ESC] to exit the menu.
26.4.2
162 en | B920 Settings menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
KeypressUse the Keypress function to activate or deactivate thekeypress tone. Activating and deactivating the keypress tone:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Settings menu option, and
press [ENTER], or simply press [5].3. Use [NEXT] to go to the Keypad menu option, and
press [ENTER], or simply press [4].4. Use [NEXT] to go to the Keypress menu option, and
press [ENTER], or simply press [3].5. Press [ENTER] to toggle between the On and Off
options.6. Press [ESC] to exit the menu.
26.4.3
Control Panels B920 Settings menu | en 163
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
B920 Shortcuts menuUse shortcuts to quickly access common functions. Using a shortcut:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Shortcuts menu option, and
press [ENTER], or simply press [6].3. Use [PREV] or [NEXT] to go to the Shortcut you wish
to run, and then press [ENTER]. The shortcut runs.
27
164 en | B920 Shortcuts menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
B920 Events menuUse the Events menu to view event memory, clear eventmemory, or view the event log.
View Event Memory
Your security system stores events that occurred sincethe last time memory was cleared. Use View EventMemory to view the events not previously cleared. Eachtime you turn the security system on, the event memoryis erased. Viewing event memory:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Events menu option, and
press [ENTER], or simply press [7].3. Press [1] or [ENTER] to open the view event
memory.
28
28.1
Control Panels B920 Events menu | en 165
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Clear Event Memory
Use the Clear Event Memory function to clear out eventmemory without turning your security system off and onagain. Clearing event memory:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Events menu option, and
press [ENTER], or simply press [7].3. Use [NEXT] to go to the Clear Event Memory menu
option, and press [ENTER], or simply press [2].
28.2
166 en | B920 Events menu Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
View Log
Use the View Log function to review events stored inyour security system. Reviewing past events might helpyou identify problems. Events are stored in the controlpanel’s memory in order of occurrence, and tagged withthe date and time. Viewing the log:1. Press [MENU] to open the Main menu.2. Use [NEXT] to go to the Events menu option, and
press [ENTER], or simply press [7].3. Use [NEXT] to go to the View Log menu option, and
press [ENTER], or simply press [3]. The keypadshows Enter Start Date.To view part of the log, enter the date (MM/DD) atwhich you wish to start the review. Press [ENTER].To view the entire log from the newest event, press[ENTER] without entering a start date. The date andtime of the newest event shows. Use [PREV] or[NEXT] to move through the events. If an eventdescription is longer than the display, the eventdescription scrolls horizontally.
4. Press [ESC] to exit the menu.
28.3
Control Panels B920 Events menu | en 167
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
OptionsThis section describes optional features that yoursecurity company might have programmed for you.
Two-man Rule
The Two-man Rule adds an extra step to the process ofturning off your security system by requiring two uniquepasscodes entered on the same keypad to turn off anarea. Two-man Rule is disabled for SIA compliantsystems. Two-man Rule is:
enabled on my system.
disabled on my system. Turning off with Two-man Rule enabled:1. Enter the first passcode and press [Enter] or
[ENTER]. The keypad shows a request for thesecond passcode.
2. Enter a second passcode and press [Enter] or[ENTER]. The second passcode must be differentfrom the first passcode. The area turns off.
29
29.1
168 en | Options Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Early Ambush
When the Early ambush feature is enabled, the securitysystem, requires two passcodes to turn off the area.Entering the first passcode turns the area off and beginscounting down Early Ambush Time (__ minutes). A usermust enter the second passcode before Early Ambushtime expires. Early Ambush is disabled for SIA compliantsystems. If Early Ambush time expires before a user enters thesecond passcode, the system creates a duress event. You can enter the first passcode a second time as thesecond passcode. You can enter the passcodes at the same keypad, or atdifferent keypads (if keypads are assigned to the samearea). Early Ambush is:
enabled on my system.
disabled on my system.
29.2
Control Panels Options | en 169
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Turning off with Early Ambush enabled:1. Enter the first passcode and press [Enter] or
[ENTER]. The keypad shows the system is turnedoff. Early ambush time begin counting down. Thekeypad does not indicate that early ambush time iscounting down.
2. You must enter the second passcode before theEarly Ambush time expires. Warning! Failure tocancel will result in alarm transmission and lawenforcement may be dispatched.
3. Enter a second passcode and press [Enter] or[ENTER]. The keypad shows Code 2 Validated toconfirm that the security system accepted thesecond passcode and stopped the Early Ambushtime countdown. The system does not create aduress event.
170 en | Options Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Security system limitations
Not even the most advanced security system canguarantee protection against burglary, fire, orenvironmental threats. All security systems are subjectto possible compromise or failure-to-warn for a varietyof reasons including, but not limited to, the following:– Sirens or horns placed outside the hearing range of
people in remote areas of the building or in areasthat are frequently closed off do not provide theintended protection.
– If intruders gain access through unprotected pointsof entry, the security system does not detect theintruders.
– If intruders have the technical means of bypassing,jamming, or disconnecting all or part of the securitysystem, the security system cannot detect theintruders.
– If the AC power supply is OFF and the back-upbattery is either missing or dead, the securitysystem does not detect intrusion.
– Smoke detectors cannot detect smoke in chimneys,walls, or roofs, or smoke blocked by a closed door.They might not detect smoke or fire on a level of thebuilding different from the one on which they arelocated. Smoke detectors might not be able to warn
29.3
Control Panels Options | en 171
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
in time about fires started by explosions, improperstorage of flammables, overloaded electrical circuits,or other types of hazardous conditions.
– If your security system’s method of communicationis down (phone line, cellular, or internet problems),reports from the security system to the securitycompany cannot send. Communication methods arevulnerable to compromise by several means.
Inadequate maintenance and failure to test are the mostcommon causes of alarm failure. Testing the systemonce a week is strongly recommended to ensure allsystem components are working properly. Although having a security system might make youeligible for reduced insurance premiums, the securitysystem is no substitute for insurance. Warning devicescannot compensate you for loss of life or property.
172 en | Options Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Cross points
Points can be assigned to cross point groups. When apoint in a cross point group detects an alarm, thecontrol panel starts the cross point timer. If a secondpoint in the same cross point group detects an alarmwhile the cross point timer is active, the control panelsends alarm reports for both points. If a single cross point detects an alarm and stays inalarm throughout the cross point timer, the controlpanel sends an alarm report only for that point. If asingle point in a cross point group detects an alarm andrestores while the timer is still active, the system sendsan unverified event for that point. A second alarm on thefirst point does not create an alarm event, but rather anunverified event. Cross points are:
enabled on my system.
disabled on my system.
29.4
Control Panels Options | en 173
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Fire safety and evacuation
Residential fire is a leading cause of accidental death.Most fire related deaths occur at night when occupantssuffocate in their sleep from smoke and toxic gases,rather than from burns. To help reduce this risk,implement the following program:– Make a home escape plan. Draw a map of your home
showing all doors and windows. Discuss the planwith everyone in your home.
– Know at least two ways out of every room, ifpossible. Make sure all foors and windows leadingoutside open easily.
– Have an outside meeting place (like a tree, light poleor mailbox), a safe distance from the home whereeveryone should meet.
– Practice your home fire drill at night and during theday with everyone in your home, twice each year.
– Practice using different ways out.– Teach children how to esape on their own in case
you can’t help them.– Close doors behhind you as you leave.
If the alarm sounds:– If the smoke alarm sounds, get out and stay out.
Never go back inside for people or pets.
29.5
174 en | Options Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
– If you have to escape through smoke, get low andgo under the smoke to your way out.
– Call the fire department from outside your home.
Bedroom
Family Room
Dining Room
Living Room
Kitchen Bedroom
Bedroom
MeetingPlace
Control Panels Options | en 175
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
Multiple area systems
Keypad scopeYour security company can configure your securitysystem so that keypads allow you view the status of andcontrol only one area, a group of areas, or all of theareas in your system. The areas you can view and thearea functions (actions) you can use at a keypadconstitute the keypad’s scope.
Authority levelsEach of your security system users is assigned anauthority level. An authority level determines how muchcontrol the user has for any function that requires apasscode (turning an area on, for example). Theauthority level is set for each area in a multiple areasystem so that a user can have different levels in eacharea, if desired.
Scope and authority levels combinedThe functions you can use at a keypad (turning All On,for example) are limited to the areas you have authorityin, and the areas that are within a keypad’s scope.
ExampleYour security system protects a business configured forthree areas (the office, the warehouse, and shipping),and three users (1, 2, and 3).
29.6
29.6.1
29.6.2
29.6.3
176 en | Options Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
Keypads details:– The keypad in the office area has scope for all areas.
(Users can view the status of all areas – office,warehouse, and shipping.)
– The keypad in the warehouse has scope for thewarehouse only.
– The keypad in shipping has scope for the warehouseand shipping.
Users details:– User 1 has authority to turn the office area on and
off, but no authority in the warehouse or shippingareas.
– User 2 has authority in the warehouse and shipping.– User 3 has authority in all three areas. When a user enters his or her passcode into a keypad,the security system allows the user to perform functionslimited to both the user’s authority level and thekeypad’s scope. What does this mean for the threeusers in the example? Specifically, which areas turn onwhen the user turns the system All On from eachkeypad?
Control Panels Options | en 177
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
User 1 at the office keypad
Action Areaaffected
Reason
View status? All three Keypad’s scope includesall three areas
Performpasscode-protectedfunctions?
Office User’s authority islimited to the officearea
Result of turning the system All On? Only the office areaturns on.
User 1 at the warehouse keypad
Action Areaaffected
Reason
View status? Warehouse Keypad’s scope includesonly the warehouse area
Performpasscode-protectedfunctions?
None User’s authority islimited to the officearea, which is not withinthe warehouse keypad’sscope
Result of turning the system All On? No area turns on.
178 en | Options Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
User 1 at the shipping keypad
Action Areaaffected
Reason
View status? Warehouseandshipping
Keypad’s scope includesboth the warehouse andshipping areas
Performpasscode-protectedfunctions?
None User’s authority islimited to the officearea, which is not withinthe warehouse orshipping keypad’s scope
Result of turning the system All On? No area turns on.
Control Panels Options | en 179
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
User 2 at the office keypad
Action Areaaffected
Reason
View status? All three Keypad’s scope includesall three areas
Performpasscode-protectedfunctions?
Warehouseandshipping
User’s authority islimited to thewarehouse and shippingareas
Result of turning the system All On? Only the warehouseand shipping areas turn on.
User 2 at the warehouse keypad
Action Areaaffected
Reason
View status? Warehouse Keypad’s scope includesonly the warehouse area
Performpasscode-protectedfunctions?
Warehouse User’s authorityincludes the warehousewhich is in the keypad’sscope
Result of turning the system All On? Only the warehousearea turns on.
180 en | Options Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
User 2 at the shipping keypad
Action Areaaffected
Reason
View status? Warehouseandshipping
Keypad’s scope includesboth the warehouse andshipping areas
Performpasscode-protectedfunctions?
Warehouseandshipping
User’s authority leveland the keypad’s scopeinclude both thewarehouse and shipping
Result of turning the system All On? Only the warehouseand shipping areas turn on.
Control Panels Options | en 181
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
User 3 at the office keypad
Action Areaaffected
Reason
View status? All three Keypad’s scope includesall three areas
Performpasscode-protectedfunctions?
All three User’s authorityincludes all three areas
Result of turning the system All On? All three areas turnon.
User 3 at the warehouse keypad
Action Areaaffected
Reason
View status? Warehouse Keypad’s scope includesonly the warehouse area
Performpasscode-protectedfunctions?
Warehouse User’s authorityincludes the warehousewhich is in the keypad’sscope
Result of turning the system All On? Only the warehousearea turns on.
182 en | Options Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.
User 3 at the shipping keypad
Action Areaaffected
Reason
View status? Warehouseandshipping
Keypad’s scope includesboth the warehouse andshipping areas
Performpasscode-protectedfunctions?
Warehouseandshipping
User’s authority leveland the keypad’s scopeinclude both thewarehouse and shipping
Result of turning the system All On? Only the warehouseand shipping areas turn on.
Control Panels Options | en 183
Bosch Security Systems, Inc. Owner's Manual 2012.12 | 03 | F.01U.265.453
GlossaryAll On
To turn on (arm) bothinterior points andperimeter points.
bypassSelectively removepoints from the securitysystem. A point may bebypassed in order toarm the perimeter witha window open.
closing windowA duration of timeprogrammed by yoursecurity company. Yousecurity company canprogram the system toturn on at the end ofthe window.
entry delayA programmed delay ofsystem alarm responseallowing an individual toenter an armed area
through the correctpoint and disarm thearea. If not disarmedbefore the delay timeexpires, the systembegins an alarmresponse which mayinclude reports to thecentral station.
exit delayA programmed delay ofsystem alarm responseallowing exit afterarming an area. Failureto exit before the delaytime expires, causesentry delay to begin.The system must thenbe disarmed. If notdisarmed before thedelay time expires, thesystem begins an alarmresponse which mayinclude reports to thecentral station.
184 en | Glossary Control Panels
2012.12 | 03 | F.01U.265.453 Owner's Manual Bosch Security Systems, Inc.