2-Sided Fireplace3-Pallet Design
www.keystonehardscapes.comStonegate No-Cut Designs • 2-Sided Fireplace
1
|
2-Sided Fireplace w/2-HearthsFront / Back Isometric
N.T.S.
Checked By:
Designed By: Date:
02/08/2021
Title:This document may contain proprietary information and shall not be duplicated in whole or in part,nor distributed to others without written consent of Keystone Retaining Wall Systems, Inc.
The suitability and/or manner of use of any details contained in this document is the sole responsibilityof the user. Final project specific designs shall be prepared by a licensed professional engineer.
Copyright 2021 Keystone Retaining Wall SystemsRKM
Scale:Project: Drawing No:
General Note:In consideration of freeze / thaw issuesduring the cold weather season it isrecommended that this outdoor Built-InFireplace element be protected fromrain, snow and ice as necessary.
Stonegate 3-Pallet Outdoor Fireplace Details
Outdoor Fireplace Quantity Totals:Stonegate Unit quantities as follows:· Large Unit "A" - 16"/14" = 56 Units· Medium Unit "B" - 12"/10" = 56 Units· Small Unit "C" - 6"/4" = 56 Units
4444 W 78th St, Minneapolis, MN 55435952-897-1040 1 of 16
Front IsometricBack Isometric
Gas Ventilation Note:Blocks to be removed for ventilation purposesare not shown on this sheet.
For Accessories - see page 2
www.keystonehardscapes.comStonegate No-Cut Designs • 2-Sided Fireplace
2
|
N.T.S.
Checked By:
Designed By: Date:Title:This document may contain proprietary information and shall not be duplicated in whole or in part,nor distributed to others without written consent of Keystone Retaining Wall Systems, Inc.
The suitability and/or manner of use of any details contained in this document is the sole responsibilityof the user. Final project specific designs shall be prepared by a licensed professional engineer.
Copyright 2021 Keystone Retaining Wall SystemsRKM
Scale:Project: Drawing No:
02/08/2021
Stonegate 3-Pallet Outdoor Fireplace Details
2-Sided Fireplace w/2-HearthsStonegate Certified Accessory Details
16 of4444 W 78th St, Minneapolis, MN 55435952-897-1040
Fireplace Concrete Top Note:See 9th Course Concrete Top Layout Detailsfor concrete top dimensions and details.
Fireplace Hearth Note:See 3rd Course Hearth Layout Detailsfor hearth dimensions and details.
Fireplace Burner Note:See 4th Course Layout Detailsfor Fireplace Burner dimensions and details.
Front
Back
Vents (2)
Fireplace InsertBottom Plate
Fire Glass orFire Rock
Fireplace Insert Note:See 7th Course Layout Detailsfor fireplace installation details.
Burner Insert
16
Front and or Back
Fireplace Hearth (2)
Fireplace Concrete TopAccess Door w/Vents Model FPI - D, D/S
Fireplace Burner
Fireplace Insert Model FPI-3, 3/S
See page 16 for top dimensions.
See page 9 for hearth dimensions.
See page 13 for insert details.
See page 11 for access door details.
ACCESSORIES Sold Separately
See page 10 for burner details.
www.keystonehardscapes.comStonegate No-Cut Designs • 2-Sided Fireplace
3
|
N.T.S.
Checked By:
Designed By: Date:
02/08/2021
Title:This document may contain proprietary information and shall not be duplicated in whole or in part,nor distributed to others without written consent of Keystone Retaining Wall Systems, Inc.
The suitability and/or manner of use of any details contained in this document is the sole responsibilityof the user. Final project specific designs shall be prepared by a licensed professional engineer.
Copyright 2021 Keystone Retaining Wall SystemsRKM
Scale:Project: Drawing No:
General Note:In consideration of freeze / thaw issuesduring the cold weather season it isrecommended that this outdoor Built-InFireplace element be protected fromrain, snow and ice as necessary.
Stonegate 3-Pallet Outdoor Fireplace Details
Outdoor Fireplace Quantity Totals:Stonegate Unit quantities as follows:· Large Unit "A" - 16"/14" = 56 Units· Medium Unit "B" - 12"/10" = 56 Units· Small Unit "C" - 6"/4" = 56 Units
2-Sided Fireplace w/2-HearthsBase Front / Back Isometric
4444 W 78th St, Minneapolis, MN 55435952-897-1040 2 of 16
Note:Structural support for block units overopenings not shown for visual purposes.
Front IsometricBack Isometric
Gas Ventilation Note:Blocks to be removed for ventilation purposesare not shown on this sheet.
For Accessories - see page 2
www.keystonehardscapes.comStonegate No-Cut Designs • 2-Sided Fireplace
4
|
N.T.S.
Checked By:
Designed By: Date:
02/08/2021
Title:This document may contain proprietary information and shall not be duplicated in whole or in part,nor distributed to others without written consent of Keystone Retaining Wall Systems, Inc.
The suitability and/or manner of use of any details contained in this document is the sole responsibilityof the user. Final project specific designs shall be prepared by a licensed professional engineer.
Copyright 2021 Keystone Retaining Wall SystemsRKM
Scale:Project: Drawing No:
Stonegate 3-Pallet Outdoor Fireplace Details
56''
2''
54''
2'' ±
18''
Finished Grade(May Vary)
6" (Min.) Crushed Stone or Reinforced ConcreteLeveling Pad
2-Sided Fireplace w/2-HearthsFront / Back Rotated Elevations
4444 W 78th St, Minneapolis, MN 55435952-897-1040 3 of 15
Front Rotated ElevationBack Rotated Elevation
Gas Ventilation Note:Blocks to be removed for ventilation purposesare not shown on this sheet.
www.keystonehardscapes.comStonegate No-Cut Designs • 2-Sided Fireplace
5
|
1/2" = 1'-0"
Checked By:
Designed By: Date:
02/08/2021
Title:This document may contain proprietary information and shall not be duplicated in whole or in part,nor distributed to others without written consent of Keystone Retaining Wall Systems, Inc.
The suitability and/or manner of use of any details contained in this document is the sole responsibilityof the user. Final project specific designs shall be prepared by a licensed professional engineer.
Copyright 2021 Keystone Retaining Wall SystemsRKM
Scale:Project:
Stonegate 3-Pallet Outdoor Fireplace DetailsDrawing No:
Fireplace 6" (Min.) Reinforced Concrete orCrushed Stone Leveling Pad
Fireplace 6" (Min.) Reinforced Concrete orCrushed Stone Leveling Pad
94'' (7'-10")
68'' (
5'-8
")
2-Sided Fireplace w/2-HearthsFoundation Layout Details
4444 W 78th St, Minneapolis, MN 55435952-897-1040 4 of 16
Foundation Isometric
Foundation Plan
www.keystonehardscapes.comStonegate No-Cut Designs • 2-Sided Fireplace
6
|
1/2" = 1'-0"
Checked By:
Designed By: Date:Title:This document may contain proprietary information and shall not be duplicated in whole or in part,nor distributed to others without written consent of Keystone Retaining Wall Systems, Inc.
The suitability and/or manner of use of any details contained in this document is the sole responsibilityof the user. Final project specific designs shall be prepared by a licensed professional engineer.
Copyright 2021 Keystone Retaining Wall SystemsRKM
Scale:Project: Drawing No:
Patio Aggregate Base Below
02/08/2021
Stonegate 3-Pallet Outdoor Fireplace Details
Patio Aggregate BaseBelow
Note:This Fireplace design usesKeystone Stonegate units.Units shown are dimensioned as follows:· Large Unit "A" - 16"/14"· Medium Unit "B" - 12"/10"· Small unit "C" - 6"/4"· All Units are 10" in depth / 6" in height
Keystone StonegateUnits (Typ.)
Keystone Stonegate Units (Typ.)
16''
36'' F
irepl
ace
82'' (6'-10") Fireplace
62'' (5'-2")
10'' Hearth Ext.
2-Sided Fireplace w/2-Hearths1st Course Layout Details
4444 W 78th St, Minneapolis, MN 55435952-897-1040 5 of 16
56'' (
4'-8
")
Block Removal as Req. (Typ.)(These Two Blocks Count as One Block)(See Ventilation Note)
(See Block Placement Note)
10'' Hearth Ext.
Block Removal as Req. (Typ.)(See Ventilation Note)
Block Placement Note:Partially damaged or visually impaired blockunits may be used in the interior area of thefireplace just behind the hearth extensions.Insure those units are structurally sound.
Ventilation Note:The fireplace insert manufacturer may recommend ventilation of theinterior fireplace area from a potential gas build up. If so, dependingon the recommendations, one or two blocks from either the 1st courseor 2nd course may be removed as needed. Only remove blocks fromone chosen course. Blocks marked with angular hatching aredesignated for removal as required on this course.As needed a small animal screen insert can be supplied to place inthe block removal area.If the 2nd course is to be used for venting, place and carefullycompact crushed stone or similar material to form a dense floor in theentire 1st course interior open area of the fireplace.The removed 2nd course blocks may be place in the 1st courseinterior open area in conjunction with fill material or in the fireplaceelement itself as needed.
Small Animal Screen or BurnerControl Piece Placement Isometric
Place the small animal screens and or burnercontrol unit pieces in their designatedopenings by centering the top flanges of thepieces on the top of the blocks on each side
1st Course Isometric
1st Course Plan
Block Removal as Req. (Typ.)(See Ventilation Note)
www.keystonehardscapes.comStonegate No-Cut Designs • 2-Sided Fireplace
7
|
1/2" = 1'-0"
Checked By:
Designed By: Date:Title:This document may contain proprietary information and shall not be duplicated in whole or in part,nor distributed to others without written consent of Keystone Retaining Wall Systems, Inc.
The suitability and/or manner of use of any details contained in this document is the sole responsibilityof the user. Final project specific designs shall be prepared by a licensed professional engineer.
Copyright 2021 Keystone Retaining Wall SystemsRKM
Scale:Project: Drawing No:
02/08/2021
Stonegate 3-Pallet Outdoor Fireplace Details
1st Course Below
1st Course Below
Keystone Stonegate Units (Typ.)
16''
36'' F
irepl
ace
82'' (6'-10") Fireplace
72'' (6'-0")
10'' Hearth Ext.
2-Sided Fireplace w/2-Hearths2nd Course Layout Details
4444 W 78th St, Minneapolis, MN 55435952-897-1040 6 of 16
Block Removal as Req. (Typ.)(See Ventilation Note)
Block Removal as Req. (Typ.)(See Ventilation Note)
(See Block Placement Note)
56'' (
4'-8
")
10'' Hearth Ext.
Ventilation Note:The fireplace insert manufacturer may recommend ventilation of theinterior fireplace area from a potential gas build up. If so, dependingon the recommendations, one or two blocks from either the 1st courseor 2nd course may be removed as needed. Only remove blocks fromone chosen course. Blocks marked with angular hatching aredesignated for removal as required on this course.As needed a small animal screen insert can be supplied to place inthe block removal area.If the 2nd course is to be used for venting, place and carefullycompact crushed stone or similar material to form a dense floor in theentire 1st course interior open area of the fireplace.The removed 2nd course blocks may be place in the 1st courseinterior open area in conjunction with fill material or in the fireplaceelement itself as needed.
2nd Course Isometric
2nd Course Plan
Keystone StonegateUnits (Typ.)
Small Animal Screen or BurnerControl Piece Placement Isometric
Place the small animal screens and or burnercontrol unit pieces in their designatedopenings by centering the top flanges of thepieces on the top of the blocks on each side
Note:This Fireplace design usesKeystone Stonegate units.Units shown are dimensioned as follows:· Large Unit "A" - 16"/14"· Medium Unit "B" - 12"/10"· Small unit "C" - 6"/4"· All Units are 10" in depth / 6" in height
Block Placement Note:Partially damaged or visually impaired blockunits may be used in the interior area of thefireplace just behind the hearth extensions.Insure those units are structurally sound.
Missing Small Unit Opening forBurner Control Module
www.keystonehardscapes.comStonegate No-Cut Designs • 2-Sided Fireplace
8
|
1/2" = 1'-0"
Checked By:
Designed By: Date:Title:This document may contain proprietary information and shall not be duplicated in whole or in part,nor distributed to others without written consent of Keystone Retaining Wall Systems, Inc.
The suitability and/or manner of use of any details contained in this document is the sole responsibilityof the user. Final project specific designs shall be prepared by a licensed professional engineer.
Copyright 2021 Keystone Retaining Wall SystemsRKM
Scale:Project: Drawing No:
Note:This Fireplace design usesKeystone Stonegate units.Units shown are dimensioned as follows:· Large Unit "A" - 16"/14"· Medium Unit "B" - 12"/10"· Small unit "C" - 6"/4"· All Units are 10" in depth / 6" in height
02/08/2021
Stonegate 3-Pallet Outdoor Fireplace Details
2nd Course Below
Keystone Stonegate Units (Typ.)
Keystone Stonegate Units (Typ.)
16
16''
36'' F
irepl
ace
82'' (6'-10") Fireplace
10'' Hearth Extension
62'' (5'-2")
2-Sided Fireplace w/2-Hearths3rd Course Layout Details
7 of 16
56'' (
4'-8
")
4444 W 78th St, Minneapolis, MN 55435952-897-1040
Block Placement Note:Partially damaged or visually impaired block units may be used in theinterior area of the fireplace just behind the hearth extensions.Insure those units are structurally sound.
(See Block Placement Note)
10'' Hearth Extension
2nd Course Below
3rd Course Isometric
3rd Course Plan
www.keystonehardscapes.comStonegate No-Cut Designs • 2-Sided Fireplace
9
|
1/2" = 1'-0"
Checked By:
Designed By: Date:Title:This document may contain proprietary information and shall not be duplicated in whole or in part,nor distributed to others without written consent of Keystone Retaining Wall Systems, Inc.
The suitability and/or manner of use of any details contained in this document is the sole responsibilityof the user. Final project specific designs shall be prepared by a licensed professional engineer.
Copyright 2021 Keystone Retaining Wall SystemsRKM
Scale:Project: Drawing No:
Note:This Fireplace design usesKeystone Stonegate units.Units shown are dimensioned as follows:· Large Unit "A" - 16"/14"· Medium Unit "B" - 12"/10"· Small unit "C" - 6"/4"· All Units are 10" in depth / 6" in height
Keystone Stonegate Units (Typ.)3rd Course Below
Install Hearth (See HearthInstallation Note)
02/08/2021
Stonegate 3-Pallet Outdoor Fireplace Details
Keystone Stonegate Units (Typ.)3rd Course Below
82'' (6'-10") 3rd Course Hearth Below
86'' (7'-2") Hearth
10'' 3
rd C
ours
e H
earth
Ext
ensi
on B
elow
12'' H
earth
Install Hearth
1''
1''
22'' 42'' 22''
2''
2''2''
2-Sided Fireplace w/2-Hearths3rd Course Hearth Layout Details
8 of 164444 W 78th St, Minneapolis, MN 55435952-897-1040
13''
Install Hearth(See Hearth Installation Note)Both Hearths are the Same Sizeand Positioned the Same
Install Hearth Hearth Installation Note:Install and align the hearth(s) for the fireplaceon top of the 3rd course block units hearthextension(s), as shown.Unless otherwise directed, secure the hearth(s)with approved adhesive or bonding agentas per manufacturers installation instructions.
3rd CourseHearth Isometric
3rd CourseHearth Plan
www.keystonehardscapes.comStonegate No-Cut Designs • 2-Sided Fireplace
10
|
1/2" = 1'-0"
Checked By:
Designed By: Date:Title:This document may contain proprietary information and shall not be duplicated in whole or in part,nor distributed to others without written consent of Keystone Retaining Wall Systems, Inc.
The suitability and/or manner of use of any details contained in this document is the sole responsibilityof the user. Final project specific designs shall be prepared by a licensed professional engineer.
Copyright 2021 Keystone Retaining Wall SystemsRKM
Scale:Project: Drawing No:
Note:This Fireplace design usesKeystone Stonegate units.Units shown are dimensioned as follows:· Large Unit "A" - 16"/14"· Medium Unit "B" - 12"/10"· Small unit "C" - 6"/4"· All Units are 10" in depth / 6" in height
02/08/2021
Stonegate 3-Pallet Outdoor Fireplace Details
Keystone Stonegate Units (Typ.)
Keystone Stonegate Units (Typ.)
16''
36'' F
irepl
ace
82'' (6'-10") Fireplace
20''42'' Opening20''
3rd Course w/HearthBelow
3rd Course w/HearthBelow
2-Sided Fireplace w/2-Hearths4th Course Layout Details
9 of 164444 W 78th St, Minneapolis, MN 55435952-897-1040
Install Certified Fireplace InsertBottom Plate as Required(See Fireplace Insert BottomPlate Installation Note)
Fireplace Insert Bottom Plate Installation Note:Install and align the bottom plate for the fireplace insert ontop of the 3rd course block units in the fireplace insertopening, as shown.Align the front and back of the bottom plate with the frontand back block units and fireplace hearths for properalignment.
Install the fireplace insert upper back, sides and top platesw/flanges after the installation of the 7th course.
See fireplace manufacturers assembly instructions toproperly assemble the fireplace pieces.
Install Certified Fireplace InsertBottom Plate as Required(See Fireplace Insert Bottom PlateInstallation Note)
Install Fireplace Burner Inserton Bottom Plate as Required(See Fireplace BurnerInsert Note)
Install Fireplace Burner Inserton Bottom Plate as Required(See Fireplace BurnerInsert Note)
Fireplace Burner Insert Note:It is recommended to use a stainless steel outdoorfireplace burner insert not to exceed 32"L x 8"W withsuitable hose and regulator accessories.Use 1 cubic foot ± of suitable fire glass or fire rock materialto fill the recessed section of the fireplace bottom plate.Install as per manufacturers assembly instructions.
4th Course Isometric
4th Course Plan
3rd Course w/HearthBelow
www.keystonehardscapes.comStonegate No-Cut Designs • 2-Sided Fireplace
11
|
1/2" = 1'-0"
Checked By:
Designed By: Date:Title:This document may contain proprietary information and shall not be duplicated in whole or in part,nor distributed to others without written consent of Keystone Retaining Wall Systems, Inc.
The suitability and/or manner of use of any details contained in this document is the sole responsibilityof the user. Final project specific designs shall be prepared by a licensed professional engineer.
Copyright 2021 Keystone Retaining Wall SystemsRKM
Scale:Project: Drawing No:
Note:This Fireplace design usesKeystone Stonegate units.Units shown are dimensioned as follows:· Large Unit "A" - 16"/14"· Medium Unit "B" - 12"/10"· Small unit "C" - 6"/4"· All Units are 10" in depth / 6" in height
02/08/2021
Stonegate 3-Pallet Outdoor Fireplace Details
4th Course Below
Keystone Stonegate Units (Typ.)
Keystone Stonegate Units (Typ.)
16''
36'' F
irepl
ace
82'' (6'-10") Fireplace
20''42'' Opening20''
4th Course Below
Install Certified Access Door as RequiredPrior to 6th Course Installation(See Access Door Installation Note)
Install Certified AccessDoor as Required Prior to6th Course Installation(See Access DoorInstallation Note)
Access Door Installation Note:Align the access door in the door opening so thatthe access door top support flanges of the doorframe are resting on top of the 5th course blocks.Make sure the top support flanges are bearingequally on the blocks on both sides of theopening and they also are 5" back from theoutside face of the blocks to the center of theflange so the 6th course block pin connectingchannels will be centered over the top supportflanges. After the 6th course blocks are placed,if needed, reposition the access door assemblyand secure in place as instructed.
Access Door Top Support Flange(Both Sides), (2)(See Access Door Installation Note)
5'' to ℄ of Flange (2)
2-Sided Fireplace w/2-Hearths5th Course Layout Details
10 of 164444 W 78th St, Minneapolis, MN 55435952-897-1040
5th Course Isometric
5th Course Plan
www.keystonehardscapes.comStonegate No-Cut Designs • 2-Sided Fireplace
12
|
1/2" = 1'-0"
Checked By:
Designed By: Date:Title:This document may contain proprietary information and shall not be duplicated in whole or in part,nor distributed to others without written consent of Keystone Retaining Wall Systems, Inc.
The suitability and/or manner of use of any details contained in this document is the sole responsibilityof the user. Final project specific designs shall be prepared by a licensed professional engineer.
Copyright 2021 Keystone Retaining Wall SystemsRKM
Scale:Project: Drawing No:
Note:This Fireplace design usesKeystone Stonegate units.Units shown are dimensioned as follows:· Large Unit "A" - 16"/14"· Medium Unit "B" - 12"/10"· Small unit "C" - 6"/4"· All Units are 10" in depth / 6" in height
02/08/2021
Stonegate 3-Pallet Outdoor Fireplace Details
5th Course Below
Keystone Stonegate Units (Typ.)
Keystone Stonegate Units (Typ.)
36'' F
irepl
ace
82'' (6'-10") Fireplace
20''42'' Opening20''
5th Course Below Access Door and FlangesBelow
2-Sided Fireplace w/2-Hearths6th Course Layout Details
11 of 164444 W 78th St, Minneapolis, MN 55435952-897-1040
Access Door Below - 6th Course Blocks to be PlacedOver Access Doors Built-In Lintel6th Course Isometric
6th Course Plan
www.keystonehardscapes.comStonegate No-Cut Designs • 2-Sided Fireplace
13
|
1/2" = 1'-0"
Checked By:
Designed By: Date:Title:This document may contain proprietary information and shall not be duplicated in whole or in part,nor distributed to others without written consent of Keystone Retaining Wall Systems, Inc.
The suitability and/or manner of use of any details contained in this document is the sole responsibilityof the user. Final project specific designs shall be prepared by a licensed professional engineer.
Copyright 2021 Keystone Retaining Wall SystemsRKM
Scale:Project: Drawing No:
Note:This Fireplace design usesKeystone Stonegate units.Units shown are dimensioned as follows:· Large Unit "A" - 16"/14"· Medium Unit "B" - 12"/10"· Small unit "C" - 6"/4"· All Units are 10" in depth / 6" in height
02/08/2021
Stonegate 3-Pallet Outdoor Fireplace Details
6th Course Below
Keystone Stonegate Units (Typ.)
Keystone Stonegate Units (Typ.)
36'' F
irepl
ace
82'' (6'-10") Fireplace
20''42'' Opening20''
6th Course Below
Install Certified Fireplace Insert as Required(See Fireplace Insert Upper Installation Note)
Fireplace Insert Upper Support Flanges (4x)(See Fireplace Insert Upper Installation Note)
Fireplace Insert Upper Support Flanges (4x)(See Fireplace Insert Upper Installation Note)
5'' to ℄ ofFlange (4)
Fireplace Insert Upper Installation Note:Assemble the fireplace insert upper parts in thefireplace insert opening as per manufacturersassembly instructions. Insure that the fireplace insertupper support flanges (4) are properly resting on topof the 7th course block units. Make sure the topsupport flanges are bearing equally on the blocks onboth sides of the fireplace insert opening and theyalso are 5" back from the outside face of the blocks tothe center of the flange, so the 8th course block pinconnecting channels above will be centered over thetop support flanges.After the 8th course blocks are placed, if needed,reposition the fireplace insert assembly and secure inplace as instructed.
16''
2-Sided Fireplace w/2-Hearths7th Course Layout Details
12 of 164444 W 78th St, Minneapolis, MN 55435952-897-1040
Install Certified Fireplace Insertas Required(See Fireplace Insert UpperInstallation Note)
7th Course Isometric
7th Course Plan
www.keystonehardscapes.comStonegate No-Cut Designs • 2-Sided Fireplace
14
|
1/2" = 1'-0"
Checked By:
Designed By: Date:Title:This document may contain proprietary information and shall not be duplicated in whole or in part,nor distributed to others without written consent of Keystone Retaining Wall Systems, Inc.
The suitability and/or manner of use of any details contained in this document is the sole responsibilityof the user. Final project specific designs shall be prepared by a licensed professional engineer.
Copyright 2021 Keystone Retaining Wall SystemsRKM
Scale:Project: Drawing No:
Note:This Fireplace design usesKeystone Stonegate units.Units shown are dimensioned as follows:· Large Unit "A" - 16"/14"· Medium Unit "B" - 12"/10"· Small unit "C" - 6"/4"· All Units are 10" in depth / 6" in height
02/08/2021
Stonegate 3-Pallet Outdoor Fireplace Details
7th Course Below
Keystone Stonegate Units (Typ.)
Keystone Stonegate Units (Typ.)
16''
36'' F
irepl
ace
82'' (6'-10") Fireplace
62'' (5'-2")
Fireplace Insert
Fireplace Insert andFlanges Below(Both Sides)
2-Sided Fireplace w/2-Hearths8th Course Layout Details
13 of 164444 W 78th St, Minneapolis, MN 55435952-897-1040
7th Course Below
8th Course Isometric
8th Course Plan
www.keystonehardscapes.comStonegate No-Cut Designs • 2-Sided Fireplace
15
|
1/2" = 1'-0"
Checked By:
Designed By: Date:Title:This document may contain proprietary information and shall not be duplicated in whole or in part,nor distributed to others without written consent of Keystone Retaining Wall Systems, Inc.
The suitability and/or manner of use of any details contained in this document is the sole responsibilityof the user. Final project specific designs shall be prepared by a licensed professional engineer.
Copyright 2021 Keystone Retaining Wall SystemsRKM
Scale:Project: Drawing No:
Note:This Fireplace design usesKeystone Stonegate units.Units shown are dimensioned as follows:· Large Unit "A" - 16"/14"· Medium Unit "B" - 12"/10"· Small unit "C" - 6"/4"· All Units are 10" in depth / 6" in height
02/08/2021
Stonegate 3-Pallet Outdoor Fireplace Details
8th Course Below
Keystone Stonegate Units (Typ.)
Keystone Stonegate Units (Typ.) Fireplace Insert Below
2-Sided Fireplace w/2-Hearths9th Course Layout Details
14 of 164444 W 78th St, Minneapolis, MN 55435952-897-1040
16''
36'' F
irepl
ace
82'' (6'-10") Fireplace
62'' (5'-2")
9th Course Isometric
9th Course Plan
www.keystonehardscapes.comStonegate No-Cut Designs • 2-Sided Fireplace
16
|
1/2" = 1'-0"
Checked By:
Designed By: Date:Title:This document may contain proprietary information and shall not be duplicated in whole or in part,nor distributed to others without written consent of Keystone Retaining Wall Systems, Inc.
The suitability and/or manner of use of any details contained in this document is the sole responsibilityof the user. Final project specific designs shall be prepared by a licensed professional engineer.
Copyright 2021 Keystone Retaining Wall SystemsRKM
Scale:Project: Drawing No:
Note:This Fireplace design usesKeystone Stonegate units.Units shown are dimensioned as follows:� Large Unit "A" - 16"/14"� Medium Unit "B" - 12"/10"� Small unit "C" - 6"/4"� All Units are 10" in depth / 6" in height
Install Fireplace Concrete Top Pieces (2)(See Concrete Top Installation Note)
02/08/2021
Stonegate 3-Pallet Outdoor Fireplace Details
Keystone Stonegate Units (Typ.)9th Course Below
82'' (6'-10") 9th Course Below
62'' ± (5'-2") Open Area Below
86'' ± (7'-2") Concrete Top
36'' 9
th C
ours
e B
elow
40'' C
oncr
ete
Top
16'' ±
Ope
nA
rea
Bel
ow
2-Sided Fireplace w/2-Hearths9th Course Concrete Top Layout Details
15 of 164444 W 78th St, Minneapolis, MN 55435952-897-1040
2''2''
2''
2''
9th CourseConcrete Top Isometric
9th CourseConcrete Top Plan
Keystone Stonegate Units (Typ.)9th Course Below
Install Fireplace Concrete Top Pieces (2)(See Concrete Top Installation Note)
Concrete Top "Piece"Plan View Detail
After the Fireplace Insert is Fully InstalledPlace Fire Glass or Lava Rock Materialto Fill and Cover the Burner Area of theInside of the Fireplace Insert
Concrete Top Installation Notes:Unless otherwise directed, install and secureconcrete top pieces with approved adhesive orbonding agent. (A 2-piece top is shown in the detail below but smaller sections can be used for ease of handling if preferred.)