2 Nfpa 70e Changes 2010 Rop

Embed Size (px)

Citation preview

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    1/60

    NFPA 70E 2012

    Proposed Changes to NFPA 70E

    Based on Action Taken on Proposals at

    the ROP Meeting Held the Week ofFebruary 8, 2010

    D. Ray CrowDRC Consulting, Inc.

    Paul Dobrowsky

    Innovative Technology Services 1

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    2/60

    Background

    This presentation is based on preliminary

    information.

    Review the published ROP for additional details.

    All changes are open and subject to change!

    ROC Meeting Week of October 24, 2010.433 public comments plus possible committee

    comments.

    2

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    3/60

    70E Task Group Chairs

    Task Group Chair for Article 110 is Mark McNellis.

    Task Group Chair for Article 130 is Daleep Mohla

    Task Group Chair for the Tables is James Dollard

    Task Group Chair for Article 320 - Batteries is

    Keith Schuh

    3

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    4/60

    ROP Meeting February 2010

    540 Public Proposals

    8 Committee Proposals

    Comment Closing Date: 9/3/2010

    http://www.nfpa.org/70e

    4

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    5/60

    Committee Action Key

    P = ProposalA = Accept

    R= Reject

    APA = Accept in PartAPR = Accept in Principle

    APP = Accept in Principle in Part

    H = Hold

    Example: P9 APR

    5

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    6/60

    Effective Date

    Effective date of Standard to be 180 days from

    Standards council issue date.

    p 1 A6

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    7/60

    90.2 (A) (A) Covered This standard addresses electrical

    safety requirements for employee workplacesthat are necessary for the practicalsafeguarding of employees during activities

    such as the installation, inspection, operation,maintenance, and demolition, of electricconductors, electric equipment, signaling andcommunications conductors and equipment,

    and raceways for the following:

    p 9 APR

    7

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    8/60

    90.2(A)(4)

    (4) Installations used by the electric utility,

    such as office buildings, warehouses, garages,

    machine shops, and recreational buildings,

    that are not an integral part of a generating

    plant, substation, or control center

    p 11 A

    8

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    9/60

    90.5(C)

    FPN's changed to Informational Notes

    p 13 A

    9

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    10/60

    Article 100

    Arc Rated (AR) Flame Resistant (FR)

    p 5 APR

    p 27

    p -55 APR

    10

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    11/60

    Article 100 New Definition

    Incident Energy Analysis:

    A study used to predict the incident energy ofan arc flash for a specified set of conditions.

    p 20 APR 11

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    12/60

    Article 100

    Working On:

    Intentionally coming in contact with energized

    electrical conductors or circuit parts with thehands, feet, or other body parts, with tools,probes, or with test equipment, regardless of thepersonal protective equipment a person iswearing.

    p 73 A

    12

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    13/60

    Article 100

    Many definitions were deleted that are not used

    in the standard

    Some were used in earlier editions in Chapter 4.

    13

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    14/60

    New Article 105

    New Article 105 for General Information, Scope,purpose, etc.

    p 76, 77, 80 14

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    15/60

    110.5 Multi-Employer Relationship

    (C) New

    Documentation. There shall be a documentedmeeting between the host employer and thecontract employer.

    p 82 APR

    p 83 APP

    p 87 APR

    p 88 APP

    p 89APR

    15

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    16/60

    110.6(C) Training

    including cardiopulmonary resuscitation and

    Automatic External Defibrillator (AED) use

    shall be ...

    p92 A

    16

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    17/60

    110.6(D)(1)(f) New

    The employer shall determine, throughregular supervision and through inspectionsconducted on at least an annual basis that

    each employee is complying with the safety-related work practices required by thisstandard.

    p 100 A

    17

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    18/60

    110.6(D)(3)(d) New

    (e) Retraining shall be performed at intervalsnot to exceed three years.

    p 104 A

    18

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    19/60

    110.6(E)

    The documentation shall contain the content

    of the training, each employees name and

    dates of training.

    p 105 A

    19

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    20/60

    110.7(E) ESP Procedures

    (E) Electrical Safety Program Procedures. Anelectrical safety program shall identify theprocedures for working within the limited

    approach boundary and for working withinthe arc flash boundary of energized electricalconductors and circuit parts operating at 50volts or more or where an electrical hazard

    exists before work is started. p 111 APR

    20

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    21/60

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    22/60

    110.7(H) Electrical Safety Auditing

    (H) Electrical Safety Auditing.

    (1) Electrical Safety Program. The electrical

    safety program shall be audited to help ensure

    that the principles and procedures of the

    electrical safety program are still in

    compliance with the latest requirements and

    regulations. The frequency of the audit shallnot exceed three years.

    continued

    22

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    23/60

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    24/60

    110.7(H)(3) New

    Documentation. The audit shall bedocumented.

    p 124 A

    24

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    25/60

    110.8 Working Exposed to Electrical

    Hazards

    Deletes portions of 110.8 that already exist inArticle 130.

    110.8(B)(1)(a) = 130.2(A) 110.8(B)(1)(b) = 130.3

    110.8(B)(2) = 130.1(B)(1)

    110.8(B)(3) = 130.2(D)

    p 128 APR, p 129 A, p 137 APP

    25

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    26/60

    110.9 Use of Equipment

    Relocates 130.4 to 110.9

    A. Test Instruments and Equipment.

    1. General: Only qualified persons shallperform testing work within the LimitedApproach Boundary of energized electricalconductors or circuit parts operating at 50volts or more.

    p 142 A

    26

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    27/60

    110.9(C) GFCI Protection

    Must be provided where required by Codes

    and Standards

    Testing per manufacturers instructions

    (existing)

    Outdoors

    From NEC 590.6(A)

    p 147 APR

    27

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    28/60

    110.9(B)(3)(d) New

    Informational Note: The hazard/riskevaluation procedure could also includeidentifying when the use of portable tools and

    equipment powered by sources other than120 volts ac such as batteries, air, hydraulics,etc. should be used to minimize the potentialfor injury from electrical hazards for tasks

    performed in conductive or wet locations. p 149 APR

    28

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    29/60

    110.10 New 110.10 Underground Electrical Lines and

    Equipment. Before excavation starts and wherethere exists reasonable possibility of contactingelectrical or utility lines or equipment, theemployer shall take the necessary steps tocontact the appropriate owners or authorities toidentify and mark the location of the electricallines or equipment. A hazard analysis shall beperformed to identify the appropriate safe workpractices that shall be utilized during theexcavation.

    p 151 APR

    29

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    30/60

    120.2(C)(2)

    (2) Form of Control. Three Two forms ofhazardous electrical energy control shall bepermitted: individual employee control, simplelockout/tagout, and complex lockout/tagout. For

    the individual employee control and the simplelockout/tagout, the qualified person shall be incharge. For the complex lockout/tagout, theperson in charge shall have overall responsibility.

    FPN: For an example of a lockout/tagoutprocedure, see Annex G.

    p 155 A

    30

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    31/60

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    32/60

    120.2(F)(2)(g) Grounding

    (g) Grounding. Grounding requirements for thecircuit shall be established, including whetherthe temporary protective grounding equipmentgrounds shall be installed for the duration of the

    task or temporarily are established by theprocedure. ...

    Similar changes have been made elsewhere inthe Standard where this concept is covered.

    p 175 APR

    32

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    33/60

    130.1 New

    All requirements of this article shall applywhether an incident energy analysis iscompleted or if the tables 130.7(C)(9) and

    (C)(10) are utilized in lieu of an incidentenergy analysis in accordance with 130.3Exception No. 2.

    p 186 APR

    33

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    34/60

    130.1(A) Energized electrical conductors and circuit

    parts to which an employee might be exposedshall be put into an electrically safe workcondition before an employee works within

    the Limited Approach Boundary of thoseconductors

    or parts. if any of the conditions in 130.1(A)(1)through 130.1(A)(3) exist:

    continued

    34

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    35/60

    130.1(A) (1) The employee is within the Limited Approach

    Boundary. (2) The employee is within the Arc Flash Boundary.

    (3) The employee interacts with equipment whereconductors or circuit parts are not exposed, but an

    increased risk of arc flash hazard exists. Informational Note: See definition of arc flash hazard

    in Article 100.

    p 190 APR

    35

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    36/60

    130.1(B)(1) Permit

    130.1(B)(1) When Where Required. If Whenworking within the limited approach boundaryor the arc flash boundary of exposed on

    energized electrical conductors or circuit partsthat are not placed in an electrically safe workcondition ... shall be performed by writtenpermit only.

    p 199 APR 17-6

    36

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    37/60

    130.1(B)(2)(6) Permit Elements

    (6) Results of the arc flash hazard analysis. (130.3) a. The arc flash boundary

    b. The necessary personal protective equipment

    to safely perform the assigned task. c. The available incident energy or Hazard Risk

    Category.

    Deletes (7) & (8)

    p 201 APR

    37

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    38/60

    130.2(B) Shock Boundaries

    Existing Table 130.2(C) becomes Table

    130.2(C)(1), for ac systems

    Table 130.2(C)(2) shall be used for the distances

    associated with various dc system voltages

    p 206 A

    38

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    39/60

    130.3 Exception 1 Arc Flash Hazard

    Analysis

    Deletes the exception and adds an InformationalNote

    FPN No. 3: An arc flash hazard analysis may notbe necessary for some three-phase systems ratedless than 240 volts. See IEEE 1584 for more

    information.

    p 223 A, p 229, A

    39

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    40/60

    130.3(B) PPE & PE

    The requirements of 130.7 shall apply

    regardless of the method used to select the

    equipment.

    p 245 A

    40

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    41/60

    130.3(B)(1)

    130.3(B)(1) FPN: For information onestimating the incident energy, see Annex D.For guidance on selection of arc-rated clothing

    and other personal protective equipment(PPE), see Table H.3 in Annex H.

    p 247 APR

    41

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    42/60

    130.3(C) Equipment Labeling

    (C) Equipment Labeling. Electrical equipmentsuch as switchboards, panelboards, industrialcontrol panels, meter socket enclosures andmotor control centers that are likely to requireexamination, adjustment, servicing ormaintenance while energized shall be fieldmarked with a label containing all the following

    information:

    continued

    42

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    43/60

    130.3(C) Equipment Labeling

    (1) Only one of the following: a. Available incident energy

    b. Minimum arc rating of clothing

    (2) Arc Flash Boundary

    (3) Nominal system voltage

    (4) Equipment identification

    (5) Date of arc flash hazard analysis

    p 260 APR

    43

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    44/60

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    45/60

    130.6(G) New

    G) Doors, hinged panels, and the like shall besecured to prevent their swinging into anemployee and causing the employee to contactexposed energized electrical conductors or circuitparts rated at 50 volts or more or where anelectrical hazard exists if movement of the door,hinged panel, and the like is likely to create a

    hazard.

    p 281 APR

    45

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    46/60

    130.7(C)5 New

    130.7(C)5 Hearing Protection.

    Employees shall wear hearing protection

    whenever working within the arc flash

    boundary.

    p 294 APR, p 295 APR

    46

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    47/60

    Table 130.7(C)(9)

    Moves the maximum short circuit current,

    fault clearing time from the Specific Notes 1 to

    4 into the appropriate section(s) of Table

    130.7(C)(9).

    p 318 APR

    p 323 APP

    47

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    48/60

    Table 130.7(C)(9)

    The use of N does not indicate that rubber

    insulating gloves, insulated and insulatinghand tools are not required in all cases.

    Rubber insulating gloves, insulated andinsulating hand tools may be required by130.2, 130.7(C)(6) and 130.7(D).

    p 329 APR

    48

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    49/60

    Table 130.7(C)(9)

    Adds a column to existing Table 130.7(C)(9) to

    include Arc Flash Protection Boundaries for

    each task.

    p 331 APR

    49

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    50/60

    Table 130.7(C)(9)(2) New

    Renumber existing Table 130.7(C)(9) as Table

    130.7(C)(9)(1) and adds a new Table

    130.7(C)(9)(2) for DC Hazards

    p 347a A

    50

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    51/60

    Table 130.7(C)(10)

    Includes the requirement for a balaclava inhazard/risk category 2

    2. Deletes hazard/risk category 2* and note

    10. 3. Revises all tasks currently listed as

    hazard/risk category 2* in Table 130.7(C)9 tohazard/risk category 2.

    p 348 APP, p 355 A

    51

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    52/60

    Table 130.7(C)(11)

    Combines the information found in 130.7(C)10

    and Table 130.7(C)10 and 130.7(C)11 and

    Table 130.7(C)11 into a single section and

    table.

    p 363 A

    p 365 APR

    52

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    53/60

    130.7(C)(12) Clothing Factors

    Garments that are not arc-rated shall not be

    permitted to be used to increase the arc rating

    of a clothing system.

    p 372 APR

    53

    130 7(C)(13)( ) & (b)

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    54/60

    130.7(C)(13)(a) & (b)

    Arc Flash Suits. .... When the incident energy

    exposure is greater than 12 cal/cm2 a suitably

    rated arc flash suit hood shall be used. ....

    (b) Face Protection .... Face shields with a

    wrap-around guarding to protect the face,

    chin, forehead, ears, neck area shall be used.....

    p 376 A, p 377 A54

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    55/60

    205.3 General Maintenance

    (3) Maintenance, tests and inspections shallbe documented

    p 390 APA

    55

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    56/60

    Article 320 Batteries and Rooms

    Deleted requirements related to installation

    and/or design.

    Such requirements are beyond the scope of

    NFPA 70E (and most belong in NFPA 70)

    Numerous proposals

    56

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    57/60

    Annex D 10 New

    Adds a new Annex D.10: DC Incident EnergyCalculations

    p 517a A

    57

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    58/60

    Annex F

    Revised Risk Assessment

    p 519 A

    58

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    59/60

    Annex H Revised Annex H to provide guidance on clothing

    selection. Annex H has been split into 4 sections:

    Two sections which provide guidance on selectingpersonal protective clothing when using the

    Hazard/Risk Categories and

    Two sections providing guidance on selectingpersonal protective clothing when using incident

    energy values.

    p 522 APR

    p 522a A

    p 522a A

    59

  • 8/13/2019 2 Nfpa 70e Changes 2010 Rop

    60/60

    Thank You

    Questions ?

    D. Ray Crow

    DRC Consulting, Inc.

    Paul Dobrowsky

    Innovative Technology Services