PASOLINK NEO LCTLOCAL CRAFT TERMINALProvided for Training July 2007

TOPC-E4011E-01-xxxxxx

LCT COMMUNICATION INTERFACECOMMUNICATION BETWEEN THE LCT AND THE PASOLINK NEO IS VIA THE LCT PORT OF THE CTRL MODULE. THE LCT AND THE CTRL MODULE MOUNTED ON THE PASOLINK NEO MUST BE CONNECTED USING A USB A-B TYPE CABLE. TYPE-B CONNECTS TO THE LCT PORT.LCT PC SPECIFICATION CPU RAM HDD DISPLAY PENTIUM-M 1.6GHz OR BETTER 512MB OR MORE 100 MB OR MORE FREE CAPACITY COLOR LCD (1024x768)

CD ROM DRIVE/USB-PORT / USB CABLE WITH USBB CONNECTOR

There are two types of LCT version corresponding to the IDU F/W version installed. LCT WEB applet Version 1.(Rev 1.xx.xx) is installed in the IDU and the LCT WEB Version (Rev 2.xx.xx) is installed in the PC.IDU AND LCT COMPATIBILITY LCT: 1.xx.xx CTRL: 2.xx.xx CTRL: 3.xx.xx (Open Browser and input URL) INCOMPATIBLE Please change LCT LCT: 2.xx.xx (Open Browser and input URL) (Open Application on LCT)

SOFTWARE REQUIREMENT OS WINDOWS 2000 (ENGLISH) WITH SP4 OR HIGHER WIN DOWS XP PROFESSIONAL (ENGLISH) SP2

IE 6 WITH SP2 PR HIGHER JAVA RUNTIME ENVIRONMENT V1.5.0_05 OR HIGHER LCT WEB SOFTWARE (VER 2.XX.XX)

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

1

LCT COMMUNICATION INTERFACE

For LCT Ver. 1.xx.xx & CTRL Ver. 2.xx.xx1

INSTALL USB MODEM DRIVER (NEC) INSTALL JAVA 2 RUN TIME CREATE A DIAL UP CONNECTION NAMED LCT

2

MAKE THE LCT DIALUP CONNECTION OPEN THE IE BROWSER AND ENTER THE URL Http://172.17.254.253

INSTALL FROM THE LCT WEB SETUP FILES CD, USB DRIVER JAVA RUN TIME3

LOGIN: Admin AND ENTER PASSWORD DEFAULT PASSWORD: 12345678

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

2

LCT COMMUNICATION INTERFACE

For LCT Ver. 2.xx.xx & CTRL Ver. 3.xx.xx1

INSTALL USB MODEM DRIVER (NEC) INSTALL JAVA 2 RUN TIME CREATE A DIAL UP CONNECTION NAMED LCT INSTALL FROM THE LCT WEB SETUP FILES CD, USB DRIVER JAVA RUN TIME *

2

INSTALL THE LCT WEB IN THE PC

3

MAKE THE LCT DIALUP CONNECTION START THE LCT FOR STD LOGIN: Admin AND ENTER PASSWORD DEFAULT PASSWORD: 12345678

LCT-WEB APPLET

* In later versions Java Run Time will be included in the LCT WEB Applet

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

3

LCT LOGIN1 ENTER THE USER NAME Admin AND PASSWORD (DEFAULT PASSWORD IS12345678 2 CLICK THE LOGIN LCT WEB OPENS TO ALARM/STATUS WINDOW Two User IDs are defined Admin (with Password) and User (without PW )

USER ID : AdminWITH PASSWORD, ACCESS LCT FOR MONITOR & CONTROL

USER ID : UserWITHOUT PASSWORD, ACCESS LCT FOR MONITOR ONLY

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

4

LCT MENUEquipment Setup ProvisioningE3 Setting CH Setting-1 CH # CH # LAN ( Status) CH Usage Error Report AIS Generation Report AIS Received Report AIS Received Condition AIS Activation Condition E1 Port Impedance (CH#) High BER Threshold Low BER Threshold E-BER (DMR) SD (DMR) E-BER (MUX) SD (MUX) LAN PORT SETTING Switching Function 2M Frame Port Usage Speed & Duplex Flow Control Collision Report Link Loss Forwarding MS - AIS Generation ALS Function ALS Interval Port 1 Port 2 Used Not Used Redundancy Setting Report Not Report User Interface PDH E1 PDH E1 with LAN 4 Port LAN with E1 PDH E3 with LAN SDH STM-1 1 + 0 (TERM) 1 + 1 (Hot Standby TERM) 1 + 1 (Twin Path TERM) 2 WAY PDH (REP) 16 x E1 Standard PKG (E/W LAN) 48 x E1 PKG 4 Port LAN with E1 STM-1 (Optical) STM-1 (Electrical) 1 x E3 +4E1 PKG (E/W LAN) 2 x E3 +8E1 PKG (E/W LAN) Not Used STM-1 (Optical) for APS WS / LAN Not Used Used (Main Master) Used (SUB Master) Unavailable Available QPSK 16QAM 32QAM 128QAM ALS Function Disabled 60Sec Enabled 180Sec 300Sec Transmission Capacity 10 [MB] 20 [MB] 40 [MB] 80 [MB] 80 [MB] 100 [MB] 156 [MB] Frame ID 1 - 32

CH Setting-2

Alarm Status LOF+HBER LOF 120 Ohms 75 Ohms

INTFC (Work)

BER Threshold Setting

Maintenance -1CPU Reset Download Configuration File Download Program File Download Equip Config File Upload Configuration File Upload Equip Config File Date / Time Setting Password Setting PMON Clear

SC Assignment

INTFC (Prot)

Disabled Used ON Report Disabled Disabled

Enabled XPIC Usage Not Used

LAN Port Setting

OFF Not Report Enabled Enabled

APS Function

Maintenance -2Maintenance RX SW Manual Control TX SW Manual Control TX Mute Control CW Control APS Manual Control IF Loopback Main Loopback(Near End) Main Loopback(Far End) Linearizer Control ALS Restart XPIC Control OFFLine Maintenance DADE Adjust RF Setting Antenna Alignment Mode

STM-1 Setting

Modulation Scheme

MTPC TX Power [dB] ATPC Trehsold Level [dBm] Additional ATT [dB] TX Power Control ATPC Trehsold Level [dBm] Additional ATT [dB] ATPC Range [MAX] [dB] ATPC Range [MIN] [dB] ATPC Power Mode TX SW Priority RX SW Maintenance Mode RX SW Priority RX SW Condition Early W arning APS Maintenance Mode APS Condition-SF(PROT) APS Condition-SD (B1) Lock in Usage Lock in Count (times) Lock in Detect Time (mins) Lock in Hold Time (mins) HK OUT 1 to 4 setting Relay Setting TCN Threshold (15min) TCN Threshold (1day) PMON Select CLUSTER ALM OUT 1 to 4 setting PASOLINK ALM OUT setting CLUSTER ALM IN 1 to 4 setting RX Level TCN Threshold [dBm] SES Activation XPIC Condition - Local Fail EOW2 Wxternal Setting Alarm Correlation Capability

TX RF Frequency[MHz] RX RF Frequency[MHz] Frame ID Hold Max Min TX Power Control Non Priority Manual Include EW Priority No.1 Forced Exclude EW LAN Port Usage (Main)

MTPC ATPC NOT USED P1-2 Shared/1 Port Only(Main) P1-2 Shared/1 Port Only(SC) P1-2 Separated(Main)

Condition for TX/RX SW

Condition for APS

Manual Forced Priority High Priority Low Include SD Exclude SD Used Notused

LAN Capacity (Main)

RL-3 RL-4 RL-5 RL-6 Disabled

Enabled

30%

15%

Others

Mute REF LO>>Self LO Normal Invert OFF OFF

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

5

LCT WINDOW

MENU AREADISPLAY THE MAIN LCT MENU AND EXPANDED MENUS FOR PROVISIONING, MAINTENANCE AND PMON

MAIN DISPLAY AREA COMMON AREACOMMON AREA DISPLAY COMMON CONTROL BUTTONS SET, LOGOUT, RELOAD. DISPLAY THE DETAILS OR CONTROL ITEMS OF THE SELECTED LCT MENU ITEM

PROGRESS AREADISPLAY THE RESULTS OF THE SET CONTROLS: OK OR NG

SUMMARY ALARM STATUS AREADISPLAY THE SUMMARY ALARMS OF NEO MAIN UNITS AND MAINTENANCE STATUS

DISPLAY THE LOGIN NAME AND SOFTWARE VER.

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

6

ALARM & STATUS -PDH

CTRL Detail

ODU Detail

Interface Detail Modem Detail

PMON Detail

Alarm/Status Color Code

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

7

ALARM & STATUS -SDH

CTRL Detail

ODU Detail

PMON Detail Modem Detail

Interface Detail

Alarm/Status Color Code

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

8

ALARM & STATUS -SDHMain/Sub Interface Detail

ODU Detail

PMON Detail Modem Detail

CTRL Detail

Unavailability status

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

9

EQUIPMENT SETUPWHEN PDH INTFC IS SELECTED

AFTER SELECTING ALL THE CONFIGURATION SETTINGS CLICK THE SET BUTTON TO IMPLEMENT THE SETTING

WHEN SDH INTFC IS SELECTED

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

10

PROVISIONING PDH

WHEN MTPC IS SELECTED IN EQUIPMENT SETUP

WHEN ATPC IS SELECTED IN EQUIPMENT SETUP

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

11

PROVISIONING PDH

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

12

PROVISIONING PDH LAN SETTINGTHIS MENU CONFIGURE THE LAN PORT PARAMETERS WITHIN THE LAN CAPACITY (MAIN) AND LAN PORT USAGE (MAIN) SETTING IN THE EQUIPMENT SETUP

WHEN THE LAN CAPACITY IS SET TO 2MB, 2M FRAMING ITEM APPEARS

LAN PORT SETTING FOR 16E1 AND 2-PORT LAN INTERFACE CARD

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

13

PROVISIONING SDHSELECT THE BER THRESHOLD SETTING FOR THE RADIO LINK AND FOR THE STM-1 SIGNAL FROM MUX & RADIO DIRECTIONS. CLICK ON THE APPROPRIATE RADIO BUTTON TO SELECT THE THRESHOLD SETTING

S D H

V.11 & RS-232C V.11 & RS-232C V.11 V.11 & RS-232C SC LAN

E1 (MUX) F1 (MUX) DCCr (MUX)

E1 (DMR) F1 (DMR) DCCr (DMR) DSC1 TO 4 DSC1 TO 4

E1 (MUX) F1 (MUX) DCCr (MUX)

TWO V.11 & TWO RS232 USER CHANNELS CAN BE ASSIGNED TO DSC 1 TO 4 IN THE RFCOH OR THEY CAN BE ASSIGNED TO E1, F1 & DCCr BYTES IN THE RSOH IN THE DIRECTION OF MUX OR RADIO (DMR). CLICK ON THE ARROW AND SELECT FROM THE DROP DOWN MENU THE USAGE FOR EACH USER CHANNEL . WHEN V.11 CH IS USED SELECT THE DIRECTION SETTING FROM THE APPROPRIATE RADIO BUTTON

AFTER SETTING THE PROVISIONING ITEMS CLICK THE SET BUTTON TO APPLY THE PROVISIONING SETTING.

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

14

PROVISIONING STM-1 SETTING

MS-AIS GENERATION SETTING IS USED TO STOP SENDING MS-AIS SIGNAL DUE TO RADIO LINK OR EQUIPMENT FAILURE. WHEN DISABLED:- DURING FAILURE OPTICAL INTFC WILL STOP TRANSMITTING THE OPTICAL SIGNAL, ELECTRICAL INTFC WILL SEND UNFRAMED AIS. WHEN ENABLED:- SEND MS-AIS DUE TO RADIO LINK OR EQUIPMENT FAILURE.

AUTOMATIC LASER SHUT DOWN (ALS) FUNCTION IS AVAILABLE ONLY FOR OPTICAL INTFC . DURING LOS OF SIGNAL AT THE INPUT OF THE OPTICAL INTFC IT WILL CUT THE LASER OUTPUT FROM THE OUTPUT OF THE OPTICAL INTFC. DURING THIS TIME AT DEFINED INTERVALS INTFC WILL OUTPUT A 2 SEC LASER PULSE. SELECT ENABLE OR DISABLE FROM THE ALS FUNCTION RADIO BUTTON IF ENABLE IS SELECTED, SELECT ALS INTERVAL FROM 60, 180, AND 300 SEC .

AFTER SETTING THE PROVISIONING ITEMS CLICK THE SET BUTTON TO APPLY THE PROVISIONING SETTING.

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

15

PROVISIONING - APSTHIS MENU ITEM APPEARS WHEN APS FUNCTION AVAILABLE, IS SET IN THE SETUP CONFIGURATION. OPTICAL INTFC SHOULD BE MOUNTED IN MAIN & SUB SLOTS APS MAINTENANCE MODE: MANUAL: WHEN SWITCHING MANUALLY UNDER MAINTENANCE MODE, PREVENT SWITCHING TO AN ALARMED INTFC (ROUTE) FORCED: WHEN SWITCHING MANUALLY UNDER MAINTENANCE MODE, FORCIBLY SWITCH TO THE SELECTED INTFC DISREGARDING ITS ALARM STATUS ( THIS MAY INTERRUPT TRAFFIC)

APS CONDITION SF (PROT) APPLIES WHEN FORCED MANUAL SWITCHOVER TO PROTECTION INTFC IS MADE PRIORITY HIGH: WHEN SIGNAL FAIL (SF) OCCURS IN THE PROTECTION INTFC, KEEPS THE ONLINE, ON WORK INTFC PRIORITY LOW: IGNORE THE SIGNAL FAIL CONDITION IN FORCED MANUAL, SWITCHOVER TO PROT INTFC APS CONDITION SD (B1) INCLUDE SD: SELECT THIS TO CONSIDER STM-1 SIGNAL DEGRADE (SD) AS A CONDITION FOR APS SWITCHING EXCLUDE SD: SELECT THIS TO EXCLUDE STM-1 SIGNAL DEGRADE (SD) AS A CONDITION FOR APS SWITCHING LOCK IN USAGE USED: WHEN FREQUENT SWITCHING OCCURS BETWEEN WORK & PROT, PAUSE SWITCHOVER UNTIL CONDITIONS SET IN LOCK IN COUNT, LOCK IN DETECT TIME & LOCK IN HOLD TIME ARE MET NOT USED: ALLOW FREQUENT SWITCH OVER BETWEEN WORK & PROT INTFC.

LOCK IN USAGE SET TO USED LOCK IN COUNT: NUMBER OF SWITCHOVERS DETECTED WITHIN LOCK IN DETECT TIME TO PAUSE SWITCHOVER ACTION LOCK IN DETECT TIME: SET THE TIME IN MINUTES. DURING WHICH THE NUMBER OF SWITCHOVER ARE COUNTED FOR LOCK IN FUNCTION LOCK IN HOLD TIME: SET THE DURATION OF SWITCHOVER PAUSE IN HOURS AFTER LOCK IN IS SET. AFTER SETTING THE PROVISIONING ITEMS CLICK THE SET BUTTON TO APPLY THE PROVISIONING SETTING.

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

16

PROVISIONING COMMON

TX & RX SW PRIORITY NON PRIORITY: SELECT THIS FOR NON HOMING SWITCHING. PRIORITY NO.1: SELECT THIS FOR HOMING SWITCHING. WHEN BOTH CHANNELS ARE NORMAL USE No.1 AS ONLINE. CH NO.1 FAILS SWITCH TO CH NO.2, WHEN CH NO.1 IS NORMALIZED SWITCH BACK TO CH NO.1 AUTOMATICALLY

RX SW MAINTENANCE MODE: MANUAL: WHEN SWITCHING MANUALLY UNDER MAINTENANCE MODE, PREVENT SWITCHING TO AN ALARMED CHANNEL (ROUTE) FORCED: WHEN SWITCHING MANUALLY UNDER MAINTENANCE MODE, FORCIBLY SWITCH TO THE SELECTED CH DISREGARDING ITS ALARM STATUS ( THIS MAY INTERRUPT TRAFFIC)

RX SW CONDITION EARLY WARNING: INCLUDE EW: SELECT THIS TO INCLUDE EW AS A CRITERIA FOR AUTO REDUNDANCY SWITCHING IN (1+1) CONFIGURATION EXCLUDE EW: SELECT THIS TO EXCLUDE EW AS A CRITERIA FOR AUTO REDUNDANCY SWITCHING IN (1+1) CONFIGURATION EARLY WARNING BER SETTING IS 1E-9

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

17

PROVISIONING TX POWER CONTROLTX POWER CONTROL - MTPC TX POWER CONTROL - ATPC

No.1 & No.2 IS INDICATED FOR (1+1) TWIN PATH CONFIGURATION

MTPC MODE: MPTC TX POWER : ENTER A NEGATIVE VALUE IN dB (AMOUNT OF ATTENUATION FROM THE ODU NOMINAL TX POWER) ATPC THRESHOLD: ENTER THE RX THRESHOLD VALUE TO BE USED WHEN OPPOSITE STATION IS IN ATPC MODE (SET IN 1 dB STEPS)

ATPC MODE: ATPC THRESHOLD: ENTER THE RX THRESHOLD VALUE TO BE USED WHEN OPPOSITE STATION IS IN ATPC MODE ADDITIONAL ATT: 0 TO 5 dB ADDITIONAL ATTENUATION IN 1 DB STEPS ( IN ADDITION TO THE ATPC RANGE) (DEPENDS ON THE MODULATION) ATPC RANGE (MAX): MAXIMUM POWER LEVEL UNDER ATPC CONTROL IS DEFINED BY THIS ITEM (AMOUNT OF ATTENUATION FROM THE ODU NOMINAL TX POWER) ATPC RANGE (MIN): MINIMUM POWER LEVEL UNDER ATPC CONTROL IS DEFINED BY THIS ITEM (AMOUNT OF ATTENUATION FROM THE ODU NOMINAL TX POWER) ATPC POWER MODE: THIS ITEM DEFINED THE ODU TX POWER SETTING DURING ATPC CONTROL FAILURE HOLD: TO MAINTAIN THE CURRENT TX POWER AT THE TIME OF ATPC CONTROL FAILURE AFTER SETTING THE PROVISIONING ITEMS CLICK THE SET BUTTON TO APPLY THE PROVISIONING SETTING. SELECT : MAX: TO TRANSMIT AT ATPC MAX POWER LEVEL AT THE TIME OF ATPC CONTROL FAILURE MIN: TO TRANSMIT AT ATPC MIN POWER LEVEL AT THE TIME OF ATPC CONTROL FAILURE

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

18

PROVISIONING RELAY SETTING

WHEN THE LAN CAPACITY IS SET TO 2MB, 2M FRAMING ITEM APPEARS

A: HOUSE KEEPING CONTROL SETTING

B: CLUSTER ALARM OUTPUT SETTING

C: PASOLINK ALARM RELAY ASSIGNMENT FOR PARALLEL ALARM OUTPUT CLICK ON A BUTTON TO ASSIGN TO RELAYS PASOLINK NEO IDU HAS 6 RELAYS WHICH CAN BE ASSIGNED TO OUTPUT PASOLINK ALARMS, CLUSTER ALARM OUTPUT AND HOUSEKEEPING ALARMS. CLUSTER ALARM INPUT ENABLE / DISABLE

IMPORTANT: FOR CLUSTER ALARM INPUT/OUTPUT, CORRESPONDING CLUSTER ALARM OUTPUT/INPUT IN THE OPPOSITE STATION MUST BE ASSIGNED OR ENABLED. IMPORTANT: FOR EACH RELAY, SELECT FROM ONE CATEGORY ONLY ( FROM A OR B OR C) TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

19

PROVISIONING TCN THRESHOLD SETTINGTCN THRESHOLD (15 MIN)

TCN THRESHOLD (15MIN): ENTER THE TCN THRESHOLD VALUES FOR ALARM OCCUR AND ALARM RECOVER FOR MUX DIRECTION AND DMR DIRECTIONTCN THRESHOLD (1 DAY)

TCN THRESHOLD (1 DAY): ENTER THE TCN THRESHOLD VALUES FOR ALARM OCCUR AND ALARM RECOVER FOR MUX DIRECTION AND DMR DIRECTION

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

20

PROVISIONING PMON SELECT

PMON SELECT

RX LEVEL TCN THRESHOLD: ENTER THE RX LEVEL THRESHOLD FOR TCN ALARM. No.1 or 2 FOR (1+1) CONFIGURATION SES ACTIVATION CONDITION: SELECT THE APPROPRIATE RADIO BUTTON FOR PERCENTAGE OF BLOCKS IN ERROR FOR SES ACTIVATION

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

21

PROVISIONING - OTHERS

OTHERS

EOW2 EXTERNAL SETTTING: THIS SETTING IS FOR BACK TO BACK CONNECTION OF EOW CALLING SIGNAL BETWEEN DIFFERENT TYPES OF PASOLINK EQUIPMENT. INVERT : SELECT THIS FOR CONNECTION BETWEEN PASOLINK+ & MX IDU NORMAL: SELECT THIS FOR CONNECTION BETWEEN PASOLINK IDU & NEO IDU ALARM CORRELATION CAPABILITY: THIS SETTING IS TO FILTER THE ALARMS AND GIVE THE MAIN (ROOT) CAUSE OF THE ALARM OFF : CORRELATION OFF GIVES THE MAIN ALARM AS WELL AS THE SECONDARY ALARMS NORMAL: CORRELATION ON, GIVES MAIN CAUSE OF THE FAILURE

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

22

METERING

(1+0) configuration

(1+1) Configuration Hot Standby+09.0 -50.4

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

23

INVENTORY

ODU Information

IDU module Information

IDU module FPGA Information

Modem Version Information IDU Network Properties Softkey related information

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

24

AUXILIARY I/O

INPUT: HOUSE KEEPING ALM INPUT CAN BE MONITORED ONLY FROM LCT.PNMx Inputs 3, 4, 5 and 6 are common to HK alarm input and Cluster alarm input. When Cluster alarms are enabled in Provisioning it cannot be used for HK ALM Input

CLUSTER ALM INPUTS CAN BE TAKEN OUT FROM THE OPPOSITE STATION CLUSTER ALM OUT RELAY.

OUTPUT: Outputs 1, 2, 3 and 4 are common to both HK Controls and Cluster Alarm outputs. Only one type should be assigned to each output.

Close: Indicate HK ALM input condition CLICK SET TO SEND SELECTED CONTROL SIGNAL Close: Indicate HK control sent out

Click on the arrow and select Open or Close to send a Control signal and click the SET Button

Shading indicates HK controls are not assigned

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

25

MAINTENANCE 1 & 2 (PDH)MAINTENANCE 1 , HAS TWO SECTIONS ONLINE AND OFFLINE. OFFLINE MAINTENANCE ITEMS MAY CAUSE INTERRUPTION IN THE RADIO LINK

MAINTENANCE CONTROL STATUS IS INDICATED IN THE VALUE COLUMN. YELLOW INDICATES MAINT CONTROL APPLIED.

SELECT THE MAINTENANCE CONTROL ITEM AND CLICK ON THE CORRESPONDING SET BUTTON

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

26

MAINTENANCE 1 & 2 (SDH)

MAINTENANCE CONTROL STATUS IS INDICATED IN THE VALUE COLUMN. YELLOW INDICATES MAINT CONTROL APPLIED.

SELECT THE MAINTENANCE CONTROL ITEM AND CLICK ON THE CORRESPONDING SET BUTTON

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

27

MAINTENANCE - 2Clear PMON data This maintenance control clear the Performance Data from the IDU memory.

To change the password Enter the old password

Enter the new password Re-Enter the new password for confirmation Click Execute to change the password Click Close to exit the change password windowTOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

28

Thank you

This training document describes the current version of the equipment. The specifications or configuration contained in this document are subject to change without notice.

TOPC-E4011E-01-xxxxxx

PASOLINK NEO LCT

29