40
Drawing Number Part Number Lead Specs. Application Pinout FS 4.2-* UL, CSA 2x22 AWG 105°C 250 VAC/300 VDC 4 A Mates with 2-pin Cordsets 1. N/C 2. N/C 3. BN 4. BU FS 4.22-* UL, CSA 2x22 AWG 105°C 250 VAC/300 VDC 4 A Mates with 2-pin Cordsets 1. BN 2. N/C 3. BU 4. N/C FS 4.4-* UL, CSA 4x22 AWG 105°C 250 VAC/300 VDC 4 A Mates with 4-pin Cordsets 1. BN 2. WH 3. BU 4. BK FS 4.4-*/S621 UL, CSA 4x18 AWG 105°C 250 VAC/300 VDC 4 A Mates with 4-pin "C" style /S622 Cordsets 1. GY1 2. GY2 3. GY3 4. GY4 FS 4.5-* UL, CSA 5x22 AWG 105°C 250 V, 4 A Mates with 5-pin Cordsets 1. BN 2. WH 3. BU 4. BK 5. GY FS 4.5-*/S627 UL, CSA 5x20 AWG 105°C 250 V, 4 A Mates with 5-pin Cordsets FS 4.5-*/S653 UL, CSA 4x22 AWG, Drain 105°C 250 V, 4 A 5.2 mm OD Mates with 5-pin Cordsets, 4 conductors PVC foil shielded with drain wire to pin 5 1. BN 2. WH 3. BU 4. BK 5. Drain FSN 5-* UL, CSA 5x22 AWG, Drain 105°C 250 V, 4 A See pinout 1. GN 2. WH 3. OG 4. BK 5. RD See page B109 for dimensional drawings. * Length in meters. Standard Lead length is 0.5 Meters. Consult factory for other lengths. Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel. To specify PVC jacketed cable, add "/S717" to the end of the part number. 1 FS(N) .. 2, 4 and 5-Wire eurofast ® Receptacles, Front Mount Male Receptacles NEMA 1, 3, 4, 6P and IEC IP 68 Protection Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

2, 4 and 5-Wire eurofast Receptacles, Front · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

  • Upload
    ngothuy

  • View
    217

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Drawing Number Part Number Lead Specs. Application Pinout

FS 4.2-*

UL, CSA2x22 AWG105°C250 VAC/300 VDC4 A

Mates with 2-pinCordsets

1. N/C2. N/C3. BN4. BU

FS 4.22-*

UL, CSA2x22 AWG105°C250 VAC/300 VDC4 A

Mates with 2-pinCordsets

1. BN2. N/C3. BU4. N/C

FS 4.4-*

UL, CSA4x22 AWG105°C250 VAC/300 VDC4 A

Mates with 4-pinCordsets

1. BN2. WH3. BU4. BK

FS 4.4-*/S621

UL, CSA4x18 AWG105°C250 VAC/300 VDC4 A

Mates with 4-pin"C" style /S622Cordsets

1. GY12. GY23. GY34. GY4

FS 4.5-*

UL, CSA5x22 AWG105°C250 V, 4 A

Mates with 5-pinCordsets 1. BN

2. WH3. BU4. BK5. GYFS 4.5-*/S627

UL, CSA5x20 AWG105°C250 V, 4 A

Mates with 5-pinCordsets

FS 4.5-*/S653

UL, CSA4x22 AWG, Drain105°C250 V, 4 A5.2 mm OD

Mates with 5-pinCordsets,4 conductors PVCfoil shielded withdrain wire to pin 5

1. BN2. WH3. BU4. BK5. Drain

FSN 5-*

UL, CSA5x22 AWG, Drain105°C250 V, 4 A

See pinout

1. GN2. WH3. OG4. BK5. RD

See page B109 for dimensional drawings.* Length in meters. Standard Lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

1

FS(N) ..

2, 4 and 5-Wire eurofast ® Receptacles, Front Mount

• Male Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 2: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Lead Specs. Application Pinout

FS 4.6-*

UL, CSA6x22 AWG105°C250 V4 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. Pk

FS 6-*

UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. Pk

FS 8-*

UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

1. WH2. BN3. GN4. Ye5. GY6. Pk7. BU8. RD

FS 8.6-*

UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

1. WH2. GN3. YE4. GY

5. GN6. N/C7. BU8. N/C

FS 10-*

UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A

Mates with 10-pinCordsets

1. WH2. BN3. GN4. YE5. GY

6. PK7. BU8. RD9. OG10. TN

FS 12-*

UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A

Mates with 12-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK

7. BU8. RD9. OG10. TN11. BK12. VT

See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

1

FS ..

6, 8, 10 and 12-Wire eurofast ® Receptacles, Front Mount

• Male Receptacles

• NEMA 1, 3, 4, 6P andIEC IP 68 Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 3: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Drawing Number Part Number Lead Specs. Application Pinout

FK 4.4-*

UL, CSA4x22 AWG105°C250 VAC/300 VDC4 A

Mates with 4-pinCordsets

1. BN2. WH3. BU4. BK

FK 4.4-*/S621

UL, CSA4x18 AWG105°C250 VAC/300 VDC4 A

Mates with 4-pin"C" style /S622Cordsets

1. GY12. GY23. GY34. GY4

FK 4.5-*

UL, CSA5x22 AWG105°C250 V, 4 A

Mates with 5-pinCordsets 1. BN

2. WH3. BU4. BK5. GYFK 4.5-*/S627

UL, CSA5x20 AWG105°C250 V, 4 A

Mates with 5-pinCordsets

FK 4.5-*/S653

UL, CSA4x22 AWG, Drain105°C250 V, 4 A5.2 mm OD

Mates with 5-pinCordsets,4 conductors PVCfoil shielded withdrain wire to pin5.

1. BN2. WH3. BU4. BK5. Drain

FKN 5-*

UL, CSA5x22 AWG, Drain105°C250 V, 4 A

See pinout

1. GN2. WH3. OG4. BK5. RD

See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FK.."; "FKV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

2

FK(N) ..

4 and 5-Wire eurofast ® Receptacles, Front Mount

• Female Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 4: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Lead Specs. Application Pinout

FK 4.6-*

UL, CSA6x22 AWG105°C250 V4 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. PK

FK 6-*

UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. PK

FK 8-*

UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD

FK 8.6-*

UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

1. WH2. GN3. YE4. GY

5. GN6. N/C7. BU8. N/C

FK 10-*

UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A

Mates with 10-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN

FK 12-*

UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A

Mates with 12-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN11. BK12. VT

See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FK.."; "FKV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

2

FK ..

• Female Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

6, 8, 10 and 12-Wire eurofast ® Receptacles, Front Mount

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 5: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Drawing Number Part Number Lead Specs. Application Pinout

FS 4.4-*/18.25

UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A

Mates with 4-pinCordsets

1. BN2. WH3. BU4. BK

FS 4.4-*/18.25/S613

UL, CSA4x18 AWG105°C250 VAC/ 300 VDC4 A

Mates with 4-pinCordsets

FS 4.4-*/18.25/S621

UL, CSA4x18 AWG105°C250 VAC/300 VDC4 A

Mates with 4-pin"C" style /S622Cordsets

1. GY12. GY23. GY34. GY4

FS 4.5-*/18.25

UL, CSA5x22 AWG105°C250 V, 4 A

Mates with 5-pinCordsets 1. BN

2. WH3. BU4. BK5. GYFS 4.5-*/18.25/S627

UL, CSA5x20 AWG105°C250 V, 4 A

Mates with 5-pinCordsets

FS 4.5-*/18.25/S653

UL, CSA4x22 AWG, Drain105°C250 V , 4 A5.2 mm OD

Mates with 5-pinCordsets,4 conductors PVCfoil shielded withdrain wire to pin 5

1. BN2. WH3. BU4. BK5. Drain

FS 4.5-*/18.25/S621

UL, CSA5x18 AWG105°C250 VAC, 4 A

Mates with 5-pin"C" style /S622Cordsets

1. GY12. GY23. GY34. GY45. GY5

See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

3

FS ..

4 and 5-Wire eurofast ® Receptacles, Front Mount, 1/4-18 NPT Threads

• Male Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 6: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Lead Specs. Application Pinout

FS 4.6-*/18.25

UL, CSA6x22 AWG105°C250 V2 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. PK

FS 6-*/18.25

UL, CSA6x24 AWG105°C60 VAC/75 VDC,2 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. PK

FS 8-*/18.25

UL, CSA8x24 AWG105°C60 VAC/75 VDC,2 A

Mates with 8-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD

FS 8-*/18.25/S1505

UL, CSA8x26 AWG105°C60 VAC/75 VDC,2 A

Mates with 8-pinCordsets

FS 8.6-*/18.25

UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

1. WH2. GN3. YE4. GY

5. GN6. N/C7. BU8. N/C

FS 10-*/18.25

UL, CSA10x24 AWG105°C60 VAC/75 VDC,2 A

Mates with 10-pinCordsets

1. WH2. BN3. GN4. YE5. GY

6. PK7. BU8. RD9. OG10. TN

FS 12-*/18.25

UL, CSA12x24 AWG105°C60 VAC/75 VDC,2 A

Mates with 12-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK

7. BU8. RD9. OG10. TN11. BK12. VT

See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

3

FS ..

6, 8, 10 and 12-Wire eurofast ® Receptacles, Front Mount, 1/4-18 NPT Threads

• Male Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 7: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Drawing Number Part Number Lead Specs. Application Pinout

FK 4.4-*/18.25

UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A

Mates with 4-pinCordsets

1. BN2. WH3. BU4. BK

FK 4.4-*/18.25/S613

UL, CSA4x18 AWG105°C250 VAC/ 300 VDC4 A

Mates with 4-pinCordsets

FK 4.4-*/18.25/S621

UL, CSA4x18 AWG105°C250 VAC/300 VDC4 A

Mates with 4-pin"C" style /S622Cordsets

1. GY12. GY23. GY34. GY4

FK 4.5-*/18.25

UL, CSA5x22 AWG105°C250 V, 4 A

Mates with 5-pinCordsets 1. BN

2. WH3. BU4. BK5. GYFK 4.5-*/18.25/S627

UL, CSA5x20 AWG105°C250 V, 4 A

Mates with 5-pinCordsets

FK 4.5-*/18.25/S653

UL, CSA4x22 AWG, Drain105°C250 V , 4 A5.2 mm OD

Mates with 5-pinCordsets,4 conductors PVCfoil shielded withdrain wire to pin 5

1. BN2. WH3. BU4. BK5. Drain

FK 4.5-*/18.25/S621

UL, CSA5x18 AWG105°C250 VAC, 4 A

Mates with 5-pin"C" style /S622Cordsets

1. GY12. GY23. GY34. GY45. GY5

See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FK.."; "FKV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

4

FK ..

• Female Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

4 and 5-Wire eurofast ® Receptacles, Front Mount, 1/4-18 NPT Threads

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 8: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Lead Specs. Application Pinout

FK 4.6-*/18.25

UL, CSA6x22 AWG105°C250 V4 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. PK

FK 6-*/18.25

UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. PK

FK 8-*/18.25

UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD

FK 8-*/18.25/S1505

UL, CSA8x26 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

FK 8.6-*/18.25

UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

1. WH2. GN3. YE4. GY

5. GN6. N/C7. BU8. N/C

FK 10-*/18.25

UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A

Mates with 10-pinCordsets

1. WH2. BN3. GN4. YE5. GY

6. PK7. BU8. RD9. OG10. TN

FK 12-*/18.25

UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A

Mates with 12-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK

7. BU8. RD9. OG10. TN11. BK12. VT

See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FK.."; "FKV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

4

FK ..

• Female Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

6, 8, 10 and 12-Wire eurofast ® Receptacles, Front Mount, 1/4-18 NPT Threads

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 9: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Drawing Number Part Number Lead Specs. Application Pinout

FS 4.4-*/14.5

UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A

Mates with 4-pinCordsets

1. BN2. WH3. BU4. BK

FS 4.4-*/14.5/S621

UL, CSA4x18 AWG105°C250 VAC/300 VDC4 A

Mates with 4-pin"C" style /S622Cordsets

1. GY12. GY23. GY34. GY4

FS 4.5-*/14.5

UL, CSA5x22 AWG105°C250 V4 A

Mates with 5-pinCordsets

1. BN2. WH3. BU4. BK5. GY

FS 4.6-*/14.5

UL, CSA6x22 AWG105°C250 V4 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. PK

FS 6-*/14.5

UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. PK

See page B109 for dimensional drawings.* Length in meters. Standard cable length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

5

FS ..

4, 5, and 6-Wire eurofast ® Receptacles, Front Mount, 1/2-14 NPSM Threads

• Male Receptacles

• NEMA 1, 3, 4, 6P andIEC IP 68 Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 10: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Lead Specs. Application Pinout

FS 8-*/14.5

UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD

FS 8.6-*/14.5

UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

1. WH2. GN3. YE4. GY5. GN6. N/C7. BU8. N/C

FS 10-*/14.5

UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A

Mates with 10-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN

FS 12-*/14.5

UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A

Mates with 12-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN11. BK12. VT

See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

5

FS ..

8, 10 and 12-Wire eurofast ® Receptacles, Front Mount, 1/2-14 NPSM Threads

• Male Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 11: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Drawing Number Part Number Lead Specs. Application Pinout

FK 4.4-*/14.5

UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A

Mates with 4-pinCordsets

1. BN2. WH3. BU4. BK

FK4.4-*/14.5/S621

UL, CSA4x18 AWG105°C250 VAC/300 VDC4 A

Mates with 4-pin"C" style /S622Cordsets

1. GY12. GY23. GY34. GY4

FK 4.5-*/14.5

UL, CSA5x22 AWG105°C250 V, 4 A

Mates with 5-pinCordsets

1. BN2. WH3. BU4. BK5. GY

FK 6-*/14.5

UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. PK

FK 8-*/14.5

UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

1. WH2. BN3. GN4. YE

5. GY6. PK7. BU8. RD

FK 8.6-*/14.5

UL, CSA6x24 AWG105°C60 VAC/75 VDC,2 A

Mates with 8-pinCordsets

1. WH2. GN3. YE4. GY

5. GN6. N/C7. BU8. N/C

FK 10-*/14.5

UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A

Mates with 10-pinCordsets

1. WH2. BN3. GN4. YE5. GY

6. PK7. BU8. RD9. OG10. TN

FK 12-*/14.5

UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A

Mates with 12-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK

7. BU8. RD9. OG10. TN11. BK12. VT

See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FK.."; "FKV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

6

FK ..

• Female Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

4, 5, 6, 8, 10 and 12-Wire eurofast ® Receptacles, Front Mount, 1/2-14 NPSM Threads

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 12: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Lead Specs. Application Pinout

FS 4.2-*/14.5/NPT

UL, CSA2x22 AWG105°C250 VAC/ 300 VDC4 A

Mates with 2-pinCordsets

1. N/C2. N/C3. BN4. BU

FS 4.22-*/14.5/NPT

UL, CSA2x22 AWG105°C250 VAC/ 300 VDC4 A

Mates with 2-pinCordsets

1. BN2. N/C3. BU4. N/C

FS 4.4-*/14.5/NPT

UL, CSA2x22 AWG105°C250 VAC/ 300 VDC4 A

Mates with 4-pinCordsets

1. BN2. WH3. BU4. BK

FS 4.5-*/14.5/NPT

UL, CSA5x22 AWG105°C250 V, 4 A

Mates with 5-pinCordsets

1. BN2. WH3. BU4. BK5. GY

FS 4.6-*/14.5/NPT

UL, CSA6x22 AWG105°C250 V4 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. PK

FS 6-*/14.5/NPT

UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A

Mates with 6-pinCordsets

See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

7

FS .. /14.5/NPT

2, 4, 5 and 6-Wire eurofast ® Receptacles, Front Mount, 1/2-14 NPT Threads

• Male Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 13: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Drawing Number Part Number Lead Specs. Application Pinout

FS 8-*/14.5/NPT

UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD

FS 8.6-*/14.5/NPT

UL, CSA6x24 AWG105°C60 VAC/75 VDC,2 A

Mates with 8-pinCordsets

1. WH2. GN3. YE4. GY5. GN6. N/C7. BU8. N/C

FS 10-*/14.5/NPT

UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A

Mates with 10-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN

FS 12-*/14.5/NPT

UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A

Mates with 12-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN11. BK12. VT

See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

7

FS .. /14.5/NPT

8, 10 and 12-Wire eurofast ® Receptacles, Front Mount, 1/2-14 NPT Threads

• Male Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 14: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Lead Specs. Application Pinout

FK 4.4-*/14.5/NPT

UL, CSA4x22 AWG105°C300 V, 4 A

Mates with 4-pinCordsets

1. BN2. WH3. BU4. BK

FK 4.5-*/14.5/NPT

UL, CSA5x22 AWG105°C250 V, 4 A

Mates with 5-pinCordsets

1. BN2. WH3. BU4. BK5. GY

FK 6-*/14.5/NPT

UL, CSA6x24 AWG105°C250 V, 4 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. PK

FK 8-*/14.5/NPT

UL, CSA8x24 AWG105°C250 V, 4 A

Mates with 8-pinCordsets

1. WH2. BN3. GN4. YE

5. GY6. PK7. BU8. RD

FK 8.6-*/14.5/NPT

UL, CSA6x24 AWG105°C60 VAC/75 VDC,2 A

Mates with 8-pinCordsets

1. WH2. GN3. YE4. GY

5. GN6. N/C7. BU8. N/C

FK 10-*/14.5/NPT

UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A

Mates with10-pin Cordsets

1. WH2. BN3. GN4. YE5. GY

6. PK7. BU8. RD9. OG10. TN

FK 12-*/14.5/NPT

UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A

Mates with12-pin Cordsets

1. WH2. BN3. GN4. YE5. GY6. PK

7. BU8. RD9. OG10. TN11. BK12. VT

See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FK.."; "FKV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

8

FK .. /14.5/NPT

• Female Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

4, 5, 6, 8 10 and 12-Wire eurofast ® Receptacles, Front Mount, 1/2-14 NPT Threads

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 15: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Drawing Number Part Number Lead Specs. Application Pinout

FS 4.4-*/13.5 W/LN

UL, CSANickel Plated Brass4x22 AWG105°C250 VAC/300 VDC4 A

Mates with 4-pinCordsets,PG 13.5 Threads

1. BN2. WH3. BU4. BK

FS 4.5-*/13.5 W/LN

UL, CSANickel Plated Brass5x22 AWG105°C250 V4 A

Mates with 5-pinCordsets,PG 13.5 Threads

1. BN2. WH3. BU4. BK5. GY

FS 4.4/18.25

105°CSolder Cup300 VAC/ 250 VDC4 A

Mates with 4-pincordset,1/4 inch 18NPTThreads

N/A

FS 4.4

105°CSolder Cup250 VAC/ 300 VDC4 A

Mates with 4-pincordset,PG 9 Threads

FS 4.5105°CSolder Cup250 V 4 A

Mates with 5-pincordset,PG 9 Threads

N/A

See page B110 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

11

FS ..

9

FS .. /13.5W/LN

10

FS .. /18.25

4 and 5-Wire eurofast ® Receptacles, Front Mount, Leads and Solder Cups

• Male Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 16: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Cable Application Pinout

FK 4.4/18.25

105°CSolder Cup300 VAC/ 250 VDC4 A

Mates with 4-pincordset,1/4-18NPT Threads

N/A

FK 4.4

105°CSolder Cup250 VAC/ 300 VDC4 A

Mates with 4-pincordset,PG 9 Threads

N/A

FK 4.5

105°CSolder Cup250 V4 A

Mates with 5-pincordset,PG 9 Threads

N/A

See page B110 for dimensional drawings.* Length in meters. Standard housing material is nickel plated brass "FK.."; "FKV.." indicates 316 stainless steel.

13

FK ..

12

FK .. /18.25

• Female Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

4 and 5-Wire eurofast ® Receptacles, Front Mount, Solder Cups

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 17: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Drawing Number Part Number Lead Specs. Application Pinout

FS 4.4-*/M20

UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A

Mates with 4-pinCordsets

1. BN2. WH3. BU4. BK

FS 4.5-*/M20

UL, CSA5x22 AWG105°C250 V, 4 A

Mates with 5-pinCordsets

1. BN2. WH3. BU4. BK5. GY

FS 6-*/M20

UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. PK

FS 8-*/M20

UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

1. WH2. BN3. GN4. YE

5. GY6. PK7. BU8. RD

FS 8.6-*/M20

UL, CSA6x24 AWG105°C60 VAC/75 VDC,2 A

Mates with 8-pinCordsets

1. WH2. GN3. YE4. GY

5. GN6. N/C7. BU8. N/C

FS 10-*/M20

UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A

Mates with 10-pinCordsets

1. WH2. BN3. GN4. YE5. GY

6. PK7. BU8. RD9. OG10. TN

FS 12-*/M20

UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A

Mates with 12-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK

7. BU8. RD9. OG10. TN11. BK12. VT

See page B110 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

14

FS .. /M20

4, 5, 6, 8, 10 and 12-Wire eurofast ® Receptacles, Front Mount, M20 Threads

• Male Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 18: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Cable Application Pinout

FK 4.4-*/M20

UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A

Mates with 4-pinCordsets

1. BN2. WH3. BU4. BK

FK 4.5-*/M20

UL, CSA5x22 AWG105°C250 V4 A

Mates with 5-pinCordsets

1. BN2. WH3. BU4. BK5. GY

FK 6-*/M20

UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. PK

FK 8-*/M20

UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

1. WH2. BN3. GN4. YE

5. GY6. PK7. BU8. RD

FK 8.6-*/M20

UL, CSA6x24 AWG105°C60 VAC/75 VDC,2 A

Mates with 8-pinCordsets

1. WH2. GN3. YE4. GY

5. GN6. N/C7. BU8. N/C

FK 10-*/M20

UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A

Mates with 10-pinCordsets

1. WH2. BN3. GN4. YE5. GY

6. PK7. BU8. RD9. OG10. TN

FK 12-*/M20

UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A

Mates with 12-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK

7. BU8. RD9. OG10. TN11. BK12. VT

See page B110 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FK.."; "FKV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

15

FK .. /M20

• Female Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

4 5, 6, 8, 10 and 12-Wire eurofast ® Receptacles, Front Mount, M20 Threads

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 19: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

4, 5, 6, 8, 10 and 12-Wire eurofast ® Receptacles, Front Mount, PG 16 Threads

Drawing Number Part Number Lead Specs. Application Pinout

FS 4.4-*/PG16

UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A

Mates with 4-pinCordset

1. BN2. WH3. BU4. BK

FS 4.5-*/PG16

UL, CSA5x22 AWG105°C250 V, 4 A

Mates with 5-pinCordset

1. BN2. WH3. BU4. BK5. GY

FS 6-*/PG16

UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A

Mates with 6-pinCordset

1. BN2. WH3. BU4. BK5. GY6. PK

FS 8-*/PG16

UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordset

1. WH2. BN3. GN4. YE

5. GY6. PK7. BU8. RD

FS 8.6-*/PG16

UL, CSA6x24 AWG105°C60 VAC/75 VDC,2 A

Mates with 8-pinCordset

1. WH2. GN3. YE4. GY

5. GN6. N/C7. BU8. N/C

FS 10-*/PG16

UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A

Mates with 10-pinCordset

1. WH2. BN3. GN4. YE5. GY

6. PK7. BU8. RD9. OG10. TN

FS 12-*/PG16

UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A

Mates with 12-pinCordset

1. WH2. BN3. GN4. YE5. GY6. PK

7. BU8. RD9. OG10. TN11. BK12. VT

See page B111 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

• Male Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

16

FS .. /PG16

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 20: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Lead Specs. Application Pinout

FKM 4.4-*

UL, CSA4x22 AWG105°C250 VAC/300 VDC4 A

Mates with 4-pinCordsets

1. BN2. WH3. BU4. BK

FKM 4.5-*

UL, CSA5x22 AWG105°C250 V, 4 A

Mates with 5-pinCordsets

1. BN2. WH3. BU4. BK5. GY

FKM 4.5-*/S653

UL, CSA4x22 AWG, Drain105°C250 V, 4 A5.2 mm OD

Mates with 5-pinCordsets,4 Conductors PVCfoil Shielded withDrain Wire topin 5

1. BN2. WH3. BU4. BK5. Drain

FKM 4.6-*

UL, CSA6x22 AWG105°C250 V2 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. PK

FKM 6-*

UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. PK

FKM 8-*

UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD

See page B111 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass.To specify PVC jacketed cable, add "/S717" to the end of the part number.

17

FKM ..

• Female Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

4, 5, 6 and 8-Wire eurofast ® Receptacles, with Rotating Coupling Nut

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 21: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Drawing Number Part Number Lead Specs. Application Pinout

FSD 4.4-*

UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A

Mates with 4-pinCordsets

1. BN2. WH3. BU4. BK

FSD 4.5-*

UL, CSA5x22 AWG105°C250 V, 4 A

Mates with 5-pinCordsets

1. BN2. WH3. BU4. BK5. GY

FSD 4.5-*/S653

UL, CSA4x22 AWG, Drain105°C250 V, 4 A5.2 mm OD

Mates with 5-pinCordsets,4 Conductors PVCfoil Shielded withDrain Wire topin 5

1. BN2. WH3. BU4. BK5. Drain

FSD 6-*

UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. PK

FSD 8-*

UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD

FSD 10-*

UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A

Mates with 10-pinCordsets

1. WH2. BN3. GN4. YE5. GY

6. PK7. BU8. RD9. OG10. TN

FSD 12-*

UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A

Mates with 12-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK

7. BU8. RD9. OG10. TN11. BK12. VT

See page B111 for dimensional drawings.* Length in meters. Standard lead length is 0.5 meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FSD.."; "FSDV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

18

FSD ..

4, 5, 6, 8, 10 and 12-Wire eurofast ® Receptacles, with Front Lock Nut

• Male Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 22: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Lead Specs. Application Pinout

FKD 4.4-*

UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A

Mates with 4-pinCordsets

1. BN2. WH3. BU4. BK

FKD 4.5-*

UL, CSA5x22 AWG105°C250 V, 4 A

Mates with 5-pinCordsets

1. BN2. WH3. BU4. BK5. GY

FKD 4.5-*/S653

UL, CSA4x22 AWG, Drain105°C250 V, 4 A5.2 mm OD

Mates with 5-pinCordsets, 4Conductors PVCfoil Shielded withDrain Wire topin 5

1. BN2. WH3. BU4. BK5. Drain

FKD 6-*

UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. PK

See page B111 for dimensional drawings.* Length in meters. Standard lead length is 0.5 meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FKD.."; "FKDV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

19

FKD ..

4, 5, and 6-Wire eurofast ® Receptacles, with Front Lock Nut

• Female Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 23: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Drawing Number Part Number Lead Specs. Application Pinout

FKD 8-*

UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD

FKD 10-*

UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A

Mates with 10-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN

FKD 12-*

UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A

Mates with 12-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN11. BK12. VT

See page B111 for dimensional drawings.* Length in meters. Standard lead length is 0.5 meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FKD.."; "FKDV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

19

FKD ..

• Female Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

8, 10 and 12-Wire eurofast ® Receptacles, with Front Lock Nut

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 24: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Lead Specs. Application Pinout

FSFD 4.4-*

UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A

Mates with 4-pinCordsets

1. BN2. WH3. BU4. BK

FSFD 4.4-*/S621

UL, CSA4x18 AWG105°C250 VAC/ 300 VDC4 A

Mates with 4-pin"C" style /S622cordsets

1. GY12. GY23. GY34. GY4

FSFD 4.5-*

UL, CSA5x22 AWG105°C250 V, 4 A

Mates with 5-pinCordsets

1. BN2. WH3. BU4. BK5. GY

FSFD 4.5-2/S653

UL, CSA4x22 AWG, Drain105°C250 V, 4 A5.2 mm OD

Mates with 5-pinCordsets,4 Conductors PVCFoil Shielded withDrain Wire to pin5

1. BN2. WH3. BU4. BK5. Drain

See page B111 for dimensional drawings.* Length in meters. Standard lead length is 0.5 meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FSFD.."; "FSFDV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

20

FSFD ..

4 and 5-Wire eurofast ® Receptacles, Rear Mount with Leads

• Male Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 25: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Drawing Number Part Number Lead Specs. Application Pinout

FSFD 6-*

UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. PK

FSFD 8-*

UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD

FSFD 8-*/S1505

UL, CSA8x26 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

FSFD 10-*

UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A

Mates with 10-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN

FSFD 12-*

UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A

Mates with 12-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN11. BK12. VT

See page B111 for dimensional drawings.* Length in meters. Standard lead length is 0.5 meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FSFD.."; "FSFDV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

20

FSFD ..

6, 8, 10 and 12-Wire eurofast ® Receptacles, Rear Mount with Leads

• Male Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 26: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Lead Specs. Application Pinout

FKFD 4.4-*

UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A

Mates with 4-pinCordsets

1. BN2. WH3. BU4. BK

FKFD 4.4-*/S621

UL, CSA4x18 AWG105°C250 VAC/ 300 VDC4 A

Mates with 4-pin"C" style /S622cordsets

1. GY12. GY23. GY34. GY4

FKFD 4.5-*

UL, CSA5x22 AWG105°C250 V, 4 A

Mates with 5-pinCordsets

1. BN2. WH3. BU4. BK5. GY

FKFD 4.5-2/S653

UL, CSA4x22 AWG, Drain105°C250 V, 4 A5.2 mm OD

Mates with 5-pinCordsets,4 Conductors PVCFoil Shielded withDrain Wire topin 5

1. BN2. WH3. BU4. BK5. Drain

See page B111 for dimensional drawings.* Length in meters. Standard lead length is 0.5 meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FKFD.."; "FKFDV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

21

FKFD ..

4 and 5-Wire eurofast ® Receptacles, Rear Mount with Leads

• Female Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 27: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Drawing Number Part Number Cable Application Pinout

FKFD 6-*

UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A

Mates with 6-pinCordsets

1. BN2. WH3. BU4. BK5. GY6. PK

FKFD 8-*

UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD

FKFD 8-*/S1505

UL, CSA8x26 AWG105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

FKFD 10-*

UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A

Mates with 10-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN

FKFD 12-*

UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A

Mates with 12-pinCordsets

1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN11. BK12. VT

See page B111 for dimensional drawings.* Length in meters. Standard lead length is 0.5 meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FKFD.."; "FKFDV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

21

FKFD ..

6, 8, 10 and 12-Wire eurofast ® Receptacles, Rear Mount with Leads

• Female Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 28: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Lead Specs. Application Pinout

FSFDL 4.4

Accepts 20 AWGMax Leads105°C250 VAC/ 300 VDC4 A

Mates with 4-pinCordsets

FSFDL 4.5

Accepts 20 AWG MaxLeads105°C250 V4 A

Mates with 5-pinCordsets

See page B111 for dimensional drawings.Standard housing material is nickel plated brass "FSFDL.."; "FSFDLV.." indicates 316 stainless steel.

22

FSFDL ..

4 and 5-Wire eurofast ® Receptacles, Rear Mount with Solder Cups

• Male Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 29: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Drawing Number Part Number Cable Application Pinout

FKFDL 4.4

Accepts 20 AWGMax Leads105°C250 VAC/ 300 VDC4 A

Mates with 4-pinCordsets

FKFDL 4.5

Accepts 20 AWG MaxLeads105°C250 V, 4 A

Mates with 5-pinCordsets

See page B111 for dimensional drawings.Standard housing material is nickel plated brass "FKFDL.."; "FKFDLV.." indicates 316 stainless steel.

23

FKFDL ..

4 and 5-Wire eurofast ® Receptacles, Rear Mount with Solder Cups

• Female Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 30: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Lead Specs. Application Pinout

FSFD 4.4105°C250 VAC/ 300 VDC4 A

Mates with 4-pinCordsets

FSFD 4.5105°C250 V, 4 A

Mates with 5-pinCordsets

FSFD 6105°C60 VAC/75 VDC2 A

Mates with 6-pinCordsets

FSFD 8105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

FSFDK 4.4

Nickel plated brass105°C250 VAC4 A

Mates with 4-pinCordsets, shortpins

FSFDK 4.5

Nickel plated brass105°C250 V, 4 A

Mates with 5-pinCordsets,short pins

See page B112 for dimensional drawings.Standard housing material is nickel plated brass "FSFD.."; "FSFDV.." indicates 316 stainless steel.

25

FSFDK ..

24

FSFD ..

4, 5, 6 and 8-Wire eurofast ® Receptacles, Rear Mount with PCB Pins

• Male Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 31: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Drawing Number Part Number Lead Specs. Application Pinout

FKFD 4.4105°C250 VAC/ 300 VDC4 A

Mates with 4-pinCordsets

FKFD 4.5105°C250 V, 4 A

Mates with 5-pinCordsets

FKFD 6105°C60 VAC/75 VDC2 A

Mates with 6-pinCordsets

FKFD 8105°C60 VAC/75 VDC2 A

Mates with 8-pinCordsets

FKFDK 4.5

Nickel Plated Brass105°C250 V, 4 A

Mates with 5-pinCordsets,Short pins

See page B112 for dimensional drawings.Standard housing material is nickel plated brass "FKFD.."; "FKFDV.." indicates 316 stainless steel.

27

FKFDK ..

26

FKFD ..

4, 5, 6 and 8-Wire eurofast ® Receptacles, Rear Mount with PCB Pins

• Female Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 32: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Cable Application Pinout

WFS 4.4-PCB105°C250 VAC/300 VDC4 A

Mates with 4-pinCordsets

WFS 4.5-PCB105°C250 V4 A

Mates with 5-pinCordsets

WFS 6-PCB105°C60 V/75 VDC2 A

Mates with 6-pinCordsets

WFS 8-PCB105°C30 VAC/ 36VDC1.5 A

Mates with 8-pinCordsets

See page B112 for dimensional drawings.Standard Material is nickel plated brass.

4, 5, 6 and 8-Wire eurofast ® Receptacles, Rear Mount with PCB Pins

28

WFS .. PCB

• Male Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 33: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Drawing Number Part Number Lead Specs. Application Pinout

FS 4.5-PCB105°C250 V4 A

Mates with 5-pinCordsets

FSFDH 4.4105°C250 VAC/300 VDC4 A

Mates with 4-pinCordsets,Separate housingand contact carrier

FSFDH 4.5105°C250 V4 A

Mates with 5-pinCordsets,Separate housingand contact carrier

WFSFDH 4.4105°C250 VAC/300 VDC4 A

Mates with 4-pinCordsets,Separate housingand contactcarrier,right angle

WFSFDH 4.5

105°C250 V4 A

Mates with 5-pinCordsets,Separate housingand contactcarrier,right angle

See page B112 - B113 for dimensional drawings.Standard Material is nickel plated brass.

• Male Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

4 and 5-Wire eurofast ® Circuit Board Mounted Receptacles

29

FS .. PCB

30A

WFSFDH ..

30

FSFDH ..

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 34: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Lead Specs. Application Pinout

FK 4.5-PCB105°C250 V4 A

Mates with 5-pinCordsets

FKFDH 4.4

105°C250 VAC/300 VDC4 A

Mates with 4-pinCordsets,separate housingand contact carrier

FKFDH 4.5

105°C250 V4 A

Mates with 5-pinCordsets,separate housingand contact carrier

WFKFDH 4.4105°C250 VAC/300 VDC4 A

Mates with 4-pinCordsets,separate housingand contactcarrier, right angle

WFKFDH 4.5105°C250 V4 A

Mates with 5-pinCordsets,separate housingand contactcarrier, right angle

FKFDHW 4.5

105°C250 V4 A

Mates with 5-pinCordsets,separate housingand contactcarrier, reverse key

See page B113 - B114 for dimensional drawings.Standard Material is nickel plated brass.

4 and 5-Wire eurofast ® Circuit Board Mount Receptacles

• Female Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

32

FK .. PCB

31B

FKFDHW ..

31

FKFDH ..

31A

WFKFDH ..

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 35: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Drawing Number Part Number Lead Specs. Application Pinout

FSW 4.5-*

UL, CSA4x22, Drain105°C250 V4 A

Mates with 5-pinReverse KeyCordset

1. BN2. WH3. BU4. BK5. GN/YE

FSW 4.5-*/S653

UL, CSA4x22 AWG, Drain105°C250 V4 A

Mates with 5-pinReverse KeyCordset, 4Conductors PVCFoil Shielded withDrain Wire to pin5

1. BN2. WH3. BU4. BK5. Drain

FSW 4.5-*/14.5

UL, CSA4x22, 1x20 AWG105°C250 V4 A

Mates with 5-pinReverse KeyCordset

1. BN2. WH3. BU4. BK5. GN/YE

FSW 4.5-*/14.5/NPT

UL, CSA4x22, 1x20 AWG105°C250 V4 A

Mates with 5-pinReverse KeyCordset

FSDW 4.5-*

UL, CSA4x22, 1x20 AWG,AWM PVC105°C250 V4 A

Mates with 5-pinReverse KeyCordset

1. BN2. WH3. BU4. BK5. GN/YE

See page B109 and 114 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FSW.."; "FSWV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

33

FSW ..

5-Wire eurofast ® Receptacles, Front Mount, Reverse Key

5

FSW .. /14.5

• Male Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

35

FSDW ..

34

FSW .. /14.5/NPT

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 36: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Cable Application Pinout

FKW 4.5-*

UL, CSA4x22, Drain105°C250 V, 4 A

Mates with 5-pinReverse KeyCordset, PG 9threads

1. BN2. WH3. BU4. BK5. GN/YE

FKW 4.5-*/S653

UL, CSA4x22 AWG, Drain105°C250 V, 4 A

Mates with 5-pinReverse KeyCordset,PG 9 threads,4 Conductors FoilShielded withDrain Wire to pin5

1. BN2. WH3. BU4. BK5. Drain

FKW 4.5-*/14.5

UL, CSA4x22, 1x20 AWG105°C250 V, 4 A

Mates with 5-pinReverse KeyCordset,1/2-14 NPSMthreads

1. BN2. WH3. BU4. BK5. GN/YE

FKMW 4.5-*

UL, CSA4x22, 1x20 AWG105°C250 V, 4 A

Mates with 5-pinReverse KeyCordset, PG 9threads, rotatingcoupling nut

1. BN2. WH3. BU4. BK5. GN/YE

FKDW 4.5-*

UL, CSA4x22, 1x20 AWG,AWM PVC105°C250 V, 4 A

Mates with 5-pinReverse KeyCordset

1. BN2. WH3. BU4. BK5. GN/YE

See page B114 - B115 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FKW.."; "FKWV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

37

FKW .. /14.5

38

FKMW ..

5-Wire eurofast ® Receptacles, Front Mount, Reverse Key

• Female Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

36

FKW ..

39

FKDW ..

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 37: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Drawing Number Part Number Lead Specs. Application Pinout

FSFDW 4.5-*

UL, CSA5x22 AWG105°C250 V, 4 A

Mates with 5-pinReverse KeyCordset, leads

1. BN2. WH3. BU4. BK5. GN/YE

FSFDLW 4.5

Accepts 20 AWG MaxLeads105°C250 V, 4 A

Mates with 5-pinReverse KeyCordset,solder cup

FSFDW 4.5105°C250 V, 4 A

Mates with 5-pinReverse KeyCordsets, PCB pins

FSFDKW 4.5105°C250 V, 4 A

Mates with 5-pinReverse KeyCordsets,short PCB pins

See page B115 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass.To specify PVC jacketed cable, add "/S717" to the end of the part number.

40

FSFDW ..

41

FSFDLW ..

43

FSFDKW ..

5-Wire eurofast ® Receptacles, Rear Mount, Reverse Key

42

FSFDW ..

• Male Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 38: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Cable Application Pinout

FKFDW 4.5-*

UL, CSA5x22 AWG105°C250 V, 4 A

Mates with 5-pinReverse KeyCordset,leads

1. BN2. WH3. BU4. BK5. GN/YE

FKFDLW 4.5

Accepts 20 AWG MaxLeads105°C250 V, 4 A

Mates with 5-pinReverse KeyCordset,solder cup

N/AFKFDW 4.5105°C250 V, 4 A

Mates with 5-pinReverse KeyCordsets, PCB Pins

FKFDKW 4.5105°C250 V, 4 A

Mates with 5-pinReverse KeyCordsets,short PCB pins

See page B115 - B116 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass.To specify PVC jacketed cable, add "/S717" to the end of the part number.

47

FKFDKW ..

46

FKFDW ..

45

FKFDLW ..

44

FKFDW ..

5-Wire eurofast ® Receptacles, Rear Mount, Reverse Key

• Female Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 39: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Drawing Number Part Number Cable Application Pinout

FKP 4.4-*

UL, CSA4x18 AWG105°C250 VAC/300 VDC4 A

Mates with 4-pinCordsets

1. BN2. WH3. BU4. BK

FKP 4.4-*/S621

UL, CSA4x18 AWG105°C250 VAC/300 VDC4 A

Mates with 4-pin"C" style /S622cordsets

1. GY12. GY23. GY34. GY4

FKP 4.5-*

UL, CSA5x18 AWG105°C250 V, 4 A

Mates with 5-pinCordsets

1. BN2. WH3. BU4. BK5. GY

FKP 4.5-*/S621

UL, CSA5x18 AWG105°C250 V, 4 A

Mates with 5-pin"C" style /S622cordsets

1. GY12. GY23. GY34. GY45. GY5

See page B116 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard Material is nickel plated brass.To specify PVC jacketed cable, add "/S717" to the end of the part number.

48

FKP ..

4 and 5-Wire eurofast ® Receptacles, Back Panel Mount

• Female Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 40: 2, 4 and 5-Wire eurofast Receptacles, Front  · PDF fileFS .. 4 and 5-Wire eurofast® Receptacles, Front Mount, 1/4-18 NPT Threads

Rece

ptac

les

Drawing Number Part Number Lead Specs. Application Pinout

FK FS 4.4/M124-conductor105°C250 V, 4 A

Mates with 4-pinCordsets, for DCApplications

FK FS 4.5/M125-conductor105°C250 V, 4 A

Mates with 5-pinCordsets, for DCApplications

FKW FSW 4.5/M125-conductor105°C250 V, 4 A

Mates with 5-pinReverse KeyCordsets, for DCApplications

FK FS 4.6/M126-conductor105°C36 V, 1.5 A

Mates with 6-pinCordsets, for DCApplications

FK FS 6/M126-conductor105°C36 V, 1.5 A

Mates with 6-pinCordsets, for DCApplications

FK FS 8/M128-conductor105°C36 V, 1.5 A

Mates with 8-pinCordsets, for DCApplications

See page B116 for dimensional drawings.Standard housing material is nickel plated brass "FK FS.."; "FKV FSV.." indicates 316 stainless steel.

• Female to Male Receptacles

• NEMA 1, 3, 4, 6P and IEC IP 68Protection

4, 5, 6 and 8-Wire eurofast ® Feed-Thru Receptacles

49

FK FS .. /M12

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]