μZMount: a millifluidic platform for high throughput screening of zebrafish Yadir A. Guerrero 1 , Julian Alberni 1 , Connor Sullivan 1 , Felicia Watson 2 , Morgan Dragan 2 , Alice Molan 2 , Huawei Wang 2 , Richard L. Klemke 2 , Deepak Solomon 1 , Nilesh Gupta 1 1 Neofluidics LLC, 6650 Lusk Blvd, Suite B102, San Diego, CA-92121, USA 2 Department of Pathology, UC San Diego & Moores Cancer Center, 9500 Gilman Drive, #0612, La Jolla, California-92093, USA ABSTRACT Zebrafish (Danio rerio) has emerged as one of the most powerful, robust, and relevant small animal model for drug discovery and development over the last decade, and there has been a large drive both from academia and industry to make it a widely-accepted model. Current tools for Zebrafish screening are complex, time and labor intensive, use anesthesia/immobilization techniques, and have limited functionalities. We have developed a user-friendly microfluidic device, μZMount, that can efficiently load, align, and manipulate Zebrafish embryos. Our device streamlines Zebrafish based screening by: (a) quick and simple embryo loading; (b) on-chip chorion removal; (c) continuous alignment of embryos/fish in the same focal plane for hassle-free imaging; (d) easy culture for up to 3 weeks post fertilization with automated food and media replenishment, as well as (e) agar-/anesthetic-free interventions for continuous drug perfusion studies. We tested our device for the above- mentioned functionalities using green fluorescent Zebrafish embryos, Tg(fli1:EGFP). We found healthy and stress-free development of larvae as there were no signs of deformations and the heart rate (beats/min) was within normal range based on published literature. To show the device’s drug screening potential, we challenged the larvae with an anti-angiogenic drug, SU-5416, and drug-mediated inhibition of intersegmental and sub- intestinal vessels sprouting was recorded using high-resolution fluorescence-microscopy. In summary, we envision our device to bridge the unmet gaps, provide a streamlined approach, and help establish Zebrafish screening into mainstream drug discovery workflows. PURPOSE METHODS RESULTS CONCLUSIONS ACKNOWLEDGEMENTS Device Construction/Layout SU-5416 Challenged Embryos 0 40 80 120 160 200 1 2 3 4 5 6 7 8 9 10 Zebrafish heart rate (beats/min) Days post fertilization (dpf) Baseline Characteristics- Normal Fish Rearing The present study demonstrates the potential of μZMount as a high throughput screening platform for zebrafish that allows for embryos to be loaded automatically into each well, dechorionation to be performed efficiently with no manual interventions and the long term culture of the fish. We investigated the effects of SU-5416 and found similar suppression of angiogenic development to published work, as well as concentration dependent dorsalization but interestingly found a normal function recovery at the highest dose levels. Quick, simple and easy embryo loading Continuous alignment in the same focal plane for imaging On -device dechorionation functionality Well suited for early and late stage fish studies Anesthetic and agar free interventions Compatible for short/long term studies Transient and continuous perfusion Easily operable through handheld/robotic pipetting systems Amenable to medium -to-high throughput operations Long Term Growth Schematic depicting zebrafish loading and screening in μ ZMount Manifold Work Flow Fish Health and Survivability Process Efficiency Heart Rate Tracking DRUG PERFUSION and MEDIA REPLENISHMENT SU-5416 (0.1μM) 0.1% DMSO SU-5416 (1μM) SU-5416 (10μM) We would like to acknowledge the contributions of the Klemke Lab who provided guidance and all of the embryos for the study. We would also like to highlight the National Institutes of Health organization as our funding source

1Neofluidics LLC, 6650 Lusk Blvd, Suite B102, San Diego ......µZMount: a millifluidic platform for high throughput screening of zebrafish Yadir A. Guerrero1, Julian Alberni1, Connor

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 1Neofluidics LLC, 6650 Lusk Blvd, Suite B102, San Diego ......µZMount: a millifluidic platform for high throughput screening of zebrafish Yadir A. Guerrero1, Julian Alberni1, Connor

µZMount: a millifluidic platform for high throughput screening of zebrafishYadir A. Guerrero1, Julian Alberni1, Connor Sullivan1, Felicia Watson2, Morgan Dragan2, Alice Molan2, Huawei Wang2, Richard L. Klemke2, Deepak Solomon1, Nilesh Gupta1

1Neofluidics LLC, 6650 Lusk Blvd, Suite B102, San Diego, CA-92121, USA2Department of Pathology, UC San Diego & Moores Cancer Center, 9500 Gilman Drive, #0612, La Jolla, California-92093, USA

ABSTRACT

Zebrafish (Danio rerio) has emerged as one of the most powerful, robust,

and relevant small animal model for drug discovery and development over

the last decade, and there has been a large drive both from academia and

industry to make it a widely-accepted model. Current tools for Zebrafish

screening are complex, time and labor intensive, use

anesthesia/immobilization techniques, and have limited functionalities. We

have developed a user-friendly microfluidic device, µZMount, that can

efficiently load, align, and manipulate Zebrafish embryos. Our device

streamlines Zebrafish based screening by: (a) quick and simple embryo

loading; (b) on-chip chorion removal; (c) continuous alignment of

embryos/fish in the same focal plane for hassle-free imaging; (d) easy

culture for up to 3 weeks post fertilization with automated food and media

replenishment, as well as (e) agar-/anesthetic-free interventions for

continuous drug perfusion studies. We tested our device for the above-

mentioned functionalities using green fluorescent Zebrafish embryos,

Tg(fli1:EGFP). We found healthy and stress-free development of larvae as

there were no signs of deformations and the heart rate (beats/min) was

within normal range based on published literature. To show the device’s

drug screening potential, we challenged the larvae with an anti-angiogenic

drug, SU-5416, and drug-mediated inhibition of intersegmental and sub-

intestinal vessels sprouting was recorded using high-resolution

fluorescence-microscopy. In summary, we envision our device to bridge

the unmet gaps, provide a streamlined approach, and help establish

Zebrafish screening into mainstream drug discovery workflows.

PURPOSE

METHODS RESULTS

CONCLUSIONS

ACKNOWLEDGEMENTS

Device Construction/Layout

SU-5416 Challenged Embryos

0

40

80

120

160

200

1 2 3 4 5 6 7 8 9 10

Zeb

rafi

sh

heart

rate

(b

eats

/min

)

Days post fertilization (dpf)

Baseline Characteristics- Normal Fish Rearing

The present study demonstrates the potential of µZMount as a high

throughput screening platform for zebrafish that allows for embryos to be

loaded automatically into each well, dechorionation to be performed

efficiently with no manual interventions and the long term culture of the

fish. We investigated the effects of SU-5416 and found similar

suppression of angiogenic development to published work, as well as

concentration dependent dorsalization but interestingly found a normal

function recovery at the highest dose levels.

Quick, simple and easy embryo loadingContinuous alignment in the same focal plane for imagingOn-device dechorionation functionalityWell suited for early and late stage fish studiesAnesthetic and agar free interventionsCompatible for short/long term studiesTransient and continuous perfusionEasily operable through handheld/robotic pipetting systemsAmenable to medium-to-high throughput operations

Long Term Growth

Schematic depicting zebrafish loading and screening in µZMount

Manifold Work Flow Fish Health and Survivability

Process EfficiencyHeart Rate Tracking

DRUG PERFUSION and MEDIA REPLENISHMENT

SU-5416 (0.1µM)

0.1% DMSO

SU-5416 (1µM) SU-5416 (10µM)