5
ABB Switzerland Ltd 1KHW001757-EN Archive No.: Rev. Date: Upgrade Options for P4LT and P4LU - _ Responsible Department: Prepared: Approved: Distribution: Lang.: Page: PSND 2006-11-15 M. Dick 2007-02-14 Ch.Leeb - EN 1/5 Valid for: Derived from: Replaces: Classification-No.: File: - - - 1KHW001757_e Upgrade Options for P4LT and P4LU.doc We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. © ABB Switzerland Ltd Power Line Carrier Equipment: Series ETL600 Upgrade Options for P4LT and P4LU Contents 1 Purpose of document 2 2 Safety instructions 2 3 Upgrade P4LU with R1LA 2 List of equipment: PC with Windows 2000 or XP HMI600 software PC P4LT/P4LU cable 1:1 serial RS-232 Torx screwdriver Size: 8 Note: Please refer 1KHW001490 for compatibility between software HMI600, firmware and hardware of ETL600.

1KHW001757_e Upgrade Options for P4LT and P4LU

Embed Size (px)

Citation preview

Page 1: 1KHW001757_e Upgrade Options for P4LT and P4LU

ABB Switzerland Ltd 1KHW001757-EN Archive No.: Rev. Date: Upgrade Options for P4LT and P4LU - _

Responsible Department: Prepared: Approved: Distribution: Lang.: Page:

PSND 2006-11-15 M. Dick 2007-02-14 Ch.Leeb - EN 1/5 Valid for: Derived from: Replaces: Classification-No.: File:

- - - 1KHW001757_e Upgrade Options for P4LT and P4LU.doc

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. © ABB Switzerland Ltd

Power Line Carrier Equipment: Series ETL600

Upgrade Options for P4LT and P4LU

Contents

1 Purpose of document 2 2 Safety instructions 2 3 Upgrade P4LU with R1LA 2

List of equipment:

PC with Windows 2000 or XP

HMI600 software PC P4LT/P4LU cable 1:1 serial RS-232 Torx screwdriver Size: 8

Note:

• Please refer 1KHW001490 for compatibility between software HMI600, firmware and hardware of ETL600.

Page 2: 1KHW001757_e Upgrade Options for P4LT and P4LU

Revision: Language: Page:

_ EN 2/5 1KHW001757-EN

1 Purpose of document

This document describes mounting of upgrade options for P4LT and P4LU.

2 Safety instructions

ESD protection

Caution The modules in this equipment contain devices, which can be damaged by electrostatic discharges. Appropriate measures must be taken before unpacking modules or withdrawing them from equipment racks. Essential precautions to prevent ESD damage when handling or working on modules are grounding straps for technical personnel and the provision of anti-static workbenches. Modules may only be shipped either in their original packing or installed in equipment racks.

ESD

3 Upgrade P4LU with R1LA

For new projects and systems the module “P4LU with R1LA” has to be ordered if LAN600 functions are required, i.e. R1LA is already assembled on P4LU ex works. In the exceptional case when a P4LU shall be upgraded with R1LA (using the optional R1LA upgrade kit), the following - rather unusual - procedure may be applied to avoid completely disassembling of the module P4LU.

Note:

The module R1LA is only compatible with P4LUa, not with P4LU and P4LT/P4LTa.

Note:

1. Switch off power to ETL600. 2. Unplug the P4LU board from ETL600 channel rack P7LC. 3. Remove the two torx screws ( Fig. 1). 4. Insert a 25 mm spacer between corner of P1LX and P4LT ( Fig. 2).

Fig. 35. Remove torx screw and washers from spacer at connector side of R1LA ( ) and put them aside.

6. Insert R1LA board ( Fig. 4) and place it such that the connector pins marked in Fig. 3 are inserted into the corresponding sockets on P1LX.

7. Fix R1LA to P1LX with washer, spring washer and torx screw from step 5 ( Fig. 5, Fig. 6).

8. Remove the spacer inserted in step 4. 9. Remount the two torx screws removed in step 3 ( Fig. 7). 10. Plug P4LU back into ETL600 channel rack P7LC. 11. Switch on power to ETL600.

Page 3: 1KHW001757_e Upgrade Options for P4LT and P4LU

Revision: Language: Page:

_ EN 3/5 1KHW001757-EN

Fig. 1 Remove the two indicated torx screws

Max 25mm!

Fig. 2 Insert a spacer with a maximum height of 25mm.

Fig. 3 Bottom side of R1LA

Torx screw and washers to be removed

Connector pins to be inserted into corresponding sockets on P1LX

Page 4: 1KHW001757_e Upgrade Options for P4LT and P4LU

Revision: Language: Page:

_ EN 4/5 1KHW001757-EN

Fig. 4 Inserting R1LA between P1LX and P4LT

Fig. 5 Tightening screw to fix R1LA in place

Page 5: 1KHW001757_e Upgrade Options for P4LT and P4LU

Revision: Language: Page:

_ EN 5/5 1KHW001757-EN

Fig. 6 R1LA installed and fixed in place with screw