16
Technical information TOV capability and protective characteristics for surge arresters type EXLIM and PEXLIM 100 110 100 120 130 140 Lightning (8/20 micros. current wave) Switch (30/60 micros. current wave) Steep (1/2 micros. current wave) Max residual voltage in percent of residual voltage at 10 kA 8/20 impulse EXLIM Q-E / LAK 4306 Rev 2 / 01-02-20 1.3 1.2 1.1 1 0.9 0.8 0.7 0.1 1 10 100 1000 10000 Time (s) TOV Strength factor (T r ) Without prior energy With prior energy = 10 kJ/kV (U r ) U c (MAX) = 0.8 x U r EXLIM T-B / LAK 4392 Rev 0 / 97-05-23

1HSM 9543 13-01en Edition 2.pdf

Embed Size (px)

Citation preview

Page 1: 1HSM 9543 13-01en Edition 2.pdf

Technical information

TOV capability and protective characteristics for surge arresters type EXLIM and PEXLIM

100

110

100

120

130

140

Lightning (8/20 micros. current wave)Switch (30/60 micros. current wave)Steep (1/2 micros. current wave)

Max residual voltage in percent of residual voltage at 10 kA 8/20 impulse

EX

LIM

Q-E

/ LA

K 4

306

Rev

2 /

01-0

2-20

1.3

1.2

1.1

1

0.9

0.8

0.70.1 1 10 100 1000 10000

Time (s)

TOV Strength factor (Tr)

Without prior energyWith prior energy = 10 kJ/kV (Ur)

Uc (MAX) = 0.8 x Ur

EXLI

M T

-B /

LAK

4392

Rev

0 /

97-0

5-23

Page 2: 1HSM 9543 13-01en Edition 2.pdf

1HSM 9543 13-01en Edition 2, 2004-11

PEXLIM R

TOV capability

Page 3: 1HSM 9543 13-01en Edition 2.pdf

1HSM 9543 13-01en Edition 2, 2004-11

PEXLIM R

Protective characteristics

Page 4: 1HSM 9543 13-01en Edition 2.pdf

1HSM 9543 13-01en Edition 2, 2004-11

PEXLIM Q

TOV capability

Page 5: 1HSM 9543 13-01en Edition 2.pdf

1HSM 9543 13-01en Edition 2, 2004-11

PEXLIM Q

Protective characteristics

Page 6: 1HSM 9543 13-01en Edition 2.pdf

1HSM 9543 13-01en Edition 2, 2004-11

PEXLIM P

TOV capability

Page 7: 1HSM 9543 13-01en Edition 2.pdf

1HSM 9543 13-01en Edition 2, 2004-11

PEXLIM P

Protective characteristics

Page 8: 1HSM 9543 13-01en Edition 2.pdf

1HSM 9543 13-01en Edition 2, 2004-11

EXLIM R

TOV capability

Page 9: 1HSM 9543 13-01en Edition 2.pdf

1HSM 9543 13-01en Edition 2, 2004-11

EXLIM R

Protective characteristics

Page 10: 1HSM 9543 13-01en Edition 2.pdf

1HSM 9543 13-01en Edition 2, 2004-11

EXLIM Q

TOV capability

Page 11: 1HSM 9543 13-01en Edition 2.pdf

1HSM 9543 13-01en Edition 2, 2004-11

EXLIM Q

Protective characteristics

Page 12: 1HSM 9543 13-01en Edition 2.pdf

1HSM 9543 13-01en Edition 2, 2004-11

EXLIM P

TOV capability

Page 13: 1HSM 9543 13-01en Edition 2.pdf

1HSM 9543 13-01en Edition 2, 2004-11

EXLIM P

Protective characteristics

Page 14: 1HSM 9543 13-01en Edition 2.pdf

1HSM 9543 13-01en Edition 2, 2004-11

EXLIM T

TOV capability

Page 15: 1HSM 9543 13-01en Edition 2.pdf

1HSM 9543 13-01en Edition 2, 2004-11

EXLIM T

Protective characteristics

Page 16: 1HSM 9543 13-01en Edition 2.pdf

1HSM 9543 13-01en Edition 2, 2004-11

ABB Power Technologies ABHigh Voltage ProductsSurge ArrestersS-771 80 Ludvika, SwedenTel: +46 (0)240 78 20 00Fax: +46 (0)240 179 83E-mail: [email protected]: www.abb.com/arrestersonline

Pro

duce

d by

PTV

HV

P/M

D M

F1H

SM

954

3 13

-01e

n E

ditio

n 2,