13
Pelco Spectra II Dome Pelco Spectra III Dome Pelco CM9760-CXTA Coaxitran Translator Sensormatic SpeedDome Ultra Vicon Surveyor 2000 External RS-422 Control PTZ Upgrade Option Installing PTZ Cameras on an Integral DVMS February 2005 #3000-40034 Rev. 9 #LQ 10027 0205

1d45b1 Integral PTZ RS-422 Field

Embed Size (px)

Citation preview

Page 1: 1d45b1 Integral PTZ RS-422 Field

Pelco Spectra II DomePelco Spectra III Dome

Pelco CM9760-CXTA Coaxitran TranslatorSensormatic SpeedDome Ultra

Vicon Surveyor 2000

External RS-422 ControlPTZ Upgrade Option

Installing PTZ Camerason an Integral DVMS

February 2005

#3000-40034 Rev. 9#LQ 10027 0205

Page 2: 1d45b1 Integral PTZ RS-422 Field

Installing PTZ Cameras on an Integral DVMS (Upgrade)February 2005

2Page

TABLE OF CONTENTS

Introduction......................................................................................... 3

Installing Pelco Spectra II or Spectra III Dome................................. 5

Installing Pelco CM9760-CXTA.......................................................... 8

Installing Sensormatic SpeedDome Ultra/DeltaDome II ................ 10

Installing Vicon Surveyor 2000........................................................ 12

Page 3: 1d45b1 Integral PTZ RS-422 Field

Installing PTZ Cameras on an Integral DVMS (Upgrade)February 2005

3Page

IntroductionThe procedure for installing PTZ cameras on an Integral DVMS varies depending on the camera manufacturer. This docu-ment covers the installation of three PTZ devices using external RS-422 control: Pelco Spectra II and Spectra III domes, PelcoCM9760-CXTA Coaxitron Translator, and Sensormatic SpeedDome Ultra/DeltaDome II. The following sections cover thespecific installation instructions for each camera. Following is a brief summary of these instructions:

• Pelco Spectra II/III Dome: Installation involves connecting the camera to a supplied RS-422 converter, connectingthe converter to an adapter cable, and plugging the cable into the DVMS. Only one pair of pins must be connectedbetween the converter (1 and 2) and the camera (RX+ and RX–). You must also select the D Type Protocol on thecamera.

• Pelco CM9760-CXTA Coaxitron Translator: Installation involves connecting cameras to the translator, connectingthe translator to the supplied RS-422 converter, connecting the converter to an adapter cable, and plugging thecable into the DVMS. Only one pair of pins must be connected from the camera to the converter: 1/2 on the RS-422converter and RX+/RX– on the translator. This scenario uses P Protocol on the translator.

• Sensormatic SpeedDome Ultra/DeltaDome II: Installation involves connecting the camera to a supplied RS-422converter, connecting the converter to an adapter cable, and plugging the cable into the DVMS. Two pairs of pinsmust be connected between the converter and the camera: 1/2 on the converter and RX+/RX– on the camera; and 3/4 on the converter and TX–/TX+ on the camera.

• Vicon Surveyor 2000: Installation involves connecting the camera to the supplied RS-422 connector connectingthe converter to an adapter cable, and plugging the cable into the DVMS. Only one pair of pins must be connectedbetween the converter (1 and 2) and the camera (RX+ and RX–).

NOTE: Only one camera manufacturer is supported at a time on each DVMS COM port.

Page 4: 1d45b1 Integral PTZ RS-422 Field

Installing PTZ Cameras on an Integral DVMS (Upgrade)February 2005

4Page

Connecting Multiple Cameras (Pelco Spectra II/III Dome, Sensormatic SpeedDome Ultra/DeltaDome II, and Vicon Surveyor 2000)Additional cameras are connected to the DVMS in a daisy chain, star, or combination configuration; the final camera in eachchain must be terminated (Vicon Surveyor 2000 is self-terminating in RS-422 mode). Each camera must have a unique addressthat matches the video input number it is connected to on the DVMS (see the recorder’s user manual). The address is set oneach camera using dip switches or dials (see “Selecting Addresses” in each installation procedure). Sample configurationsare shown in Figure 1.

See the camera manufacturer’s installation manual for more information.

Enabling COM portsThe COM ports on the DVMS must be enabled for PTZ to function. To verify that the COM ports are enabled on yoursystem, view the PTZ tab on the Setup page in MasterControl on the DVMS. If the COM ports are not enabled, the followingmessage is displayed on the PTZ tab:

Unable to detect COM ports on your system. You must install a COM portto use PTZ cameras.

If this message appears, you must enable the COM (serial) ports in the system BIOS. For assistance, please contact theTechnical Support Center at 1-317-845-9242.

FIGURE 1

DVMS

Address: 1 Address: 2 Address: 3 (terminate)

DAISY CHAIN

DVMS

Address: 1

Address: 2

Address: 3

(terminate)

(terminate)

(terminate)

STAR

DVMS

Address: 1

Address: 3

Address: 5

Address: 2 (terminate)

Address: 4 (terminate)

Address: 6 (terminate)

COMBINATION

Page 5: 1d45b1 Integral PTZ RS-422 Field

Installing PTZ Cameras on an Integral DVMS (Upgrade)February 2005

5Page

RS-422 converter pin Camera terminal pin

1 RX+

2 RX–

Installing Pelco Spectra II or Spectra III Dome on a DVMSTo upgrade a DVMS for use with a Pelco Spectra II/III Dome camera, you must wire the camera to the RS-422 converter,connect the converter to the DB-25-to-DB-9 adapter cable, and then plug the cable into the COM port on the DVMS. Pins 1and 2 on the converter must be wired to the RX+ and RX– pins on the camera, respectively (see Table 1).

TABLE 1On the Setup page inMasterControl, make sureyou select COM1 on the PTZtab for this camera.

FIGURE 2

Figure 2 illustrates the connection points between the DVMS and the camera. (Drawing not to scale; DVMS drawing may notmatch your particular DVMS model.)

Pelco Spectra II and Spectra III cameras mustbe configured as follows:

• Baud rate: 2400• Protocol: D Protocol• Address: must match input number

on the DVMS

See the following pages for more information.

1 2 3 4 5 6 7 8OFF OFF ON OFF OFF ON ON ON

Set the switch on the frontof the converter to DCE

Set the switches on the backof the converter as follows:

DVMS

2-conductor wires4 3 2 1

D C E

D T E

9VAC/DCpower adapter

DB-25 male to DB-9 femaleadapter cable

TX+TX-RX+RX-

*Only RX+ and RX-are used on camera

PelcoSpectra II/III Dome

To additional cameras(RX+ to RX+ and RX- to RX-)

Final camera must be terminated

External RS-422 converter

ON

Page 6: 1d45b1 Integral PTZ RS-422 Field

Installing PTZ Cameras on an Integral DVMS (Upgrade)February 2005

6Page

1 2 3 4 5 6 7 8OFF ON OFF OFF OFF OFF OFF ON

FIGURE 4

Pelco Spectra II/III Dome: OverviewFigure 3 shows the location of the switches used to select the protocol, camera address, and termination. Note that SpectraIII Dome autodetects the protocol. Use this diagram as a guide in the following sections.

Pelco Spectra II Dome: Selecting a ProtocolOn the back of the dome drive or camera, you must set SW1 to use the D Type Control. To do this, set the SW1 switches onthe bottom of the dome drive or camera to the settings shown in Figure 4 (ON=switch up; OFF=switch down). Note thatSpectra III Dome autodetects the protocol.

ON

SW1

SW2

Termination switch

Protocol switch (SW1)Address switch (SW2)

Pelco Spectra II Dome

FIGURE 3

SW1

Address switch(SW 1)

Termination switch(SW 2)

Unused(SW 3)

Pelco Spectra III Dome

Page 7: 1d45b1 Integral PTZ RS-422 Field

Installing PTZ Cameras on an Integral DVMS (Upgrade)February 2005

7Page

TABLE 2

Pelco Spectra II/III Dome: Selecting AddressesEach Pelco camera connected to a DVMS must have a unique physical address from 1 to 32 that matches the video inputnumber the camera is connected to. To select an address on Spectra II, set the SW2 switches on the bottom of the domedrive or camera; to select an address on Spectra III, set the SW1 switch on the side of the camera (see Figure 3). Use thesettings shown in Table 2. Remember to terminate the final camera in each chain using the termination switch.

See the Pelco Spectra II/III Dome installation manual for more information.

Baud Rate (2400)Address SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-81 OFF OFF OFF OFF OFF OFF OFF OFF2 ON OFF OFF OFF OFF OFF OFF OFF3 OFF ON OFF OFF OFF OFF OFF OFF4 ON ON OFF OFF OFF OFF OFF OFF5 OFF OFF ON OFF OFF OFF OFF OFF6 ON OFF ON OFF OFF OFF OFF OFF7 OFF ON ON OFF OFF OFF OFF OFF8 ON ON ON OFF OFF OFF OFF OFF9 OFF OFF OFF ON OFF OFF OFF OFF10 ON OFF OFF ON OFF OFF OFF OFF11 OFF ON OFF ON OFF OFF OFF OFF12 ON ON OFF ON OFF OFF OFF OFF13 OFF OFF ON ON OFF OFF OFF OFF14 ON OFF ON ON OFF OFF OFF OFF15 OFF ON ON ON OFF OFF OFF OFF16 ON ON ON ON OFF OFF OFF OFF17 OFF OFF OFF OFF ON OFF OFF OFF18 ON OFF OFF OFF ON OFF OFF OFF19 OFF ON OFF OFF ON OFF OFF OFF20 ON ON OFF OFF ON OFF OFF OFF21 OFF OFF ON OFF ON OFF OFF OFF22 ON OFF ON OFF ON OFF OFF OFF23 OFF ON ON OFF ON OFF OFF OFF24 ON ON ON OFF ON OFF OFF OFF25 OFF OFF OFF ON ON OFF OFF OFF26 ON OFF OFF ON ON OFF OFF OFF27 OFF ON OFF ON ON OFF OFF OFF28 ON ON OFF ON ON OFF OFF OFF29 OFF OFF ON ON ON OFF OFF OFF30 ON OFF ON ON ON OFF OFF OFF31 OFF ON ON ON ON OFF OFF OFF32 ON ON ON ON ON OFF OFF OFF

ExamplesON

ON

ON

Page 8: 1d45b1 Integral PTZ RS-422 Field

Installing PTZ Cameras on an Integral DVMS (Upgrade)February 2005

8Page

Installing Pelco CM9760-CXTA on a DVMSTo connect a Pelco CM9760-CXTA Coaxitron Translator to a DVMS, you must wire it to the supplied RS-422 converter,connect the converter to the DB-25-to-DB-9 adapter cable, and then plug the cable into the COM port on the DVMS. Pins 1and 2 on the RS-422 connector must be wired to the RX+ and RX– pins on the translator, respectively, using the providedcrossover cable (see Table 3).

The PTZ cameras connect directly to the top row of BNCs on the back of the translator and then loop out to the DVMSthrough the bottom row of BNCs on the translator. All camera addresses must be set to 0, and the translator input numbermust match the DVMS input number.

Figure 5 illustrates the connection points between the DVMS and the translator. (Drawing not to scale; DVMS drawing maynot match your particular DVMS model.)

TABLE 3

FIGURE 51 2 3 4 5 6 7 8

OFF OFF ON OFF OFF ON ON ON

Set the switch on the frontof the converter to DCE

Set the switches on the backof the converter as follows:

DVMS

Pelco CM9760-CXTA

To additional translator(OUT to IN)

Dip switches

1 5432 6 7 8 9 10 11 12 13 14 15 16

1 8OUT IN

Pin

8 to

Pin

1

Pin

7 to

Pin

2

PTZ camera set to C protocolSee camera manufacturer's documentation

4 3 2 1

D C E

D T E

9VAC/DCpower adapter

DB-25 male to DB-9 femaleadapter cable

External RS-422 converter

ON

RS-422 converter pin RJ-45 connector pin

Pin 2 RX– (pin 7)

Pin 1 RX+ (pin 8)

Page 9: 1d45b1 Integral PTZ RS-422 Field

Installing PTZ Cameras on an Integral DVMS (Upgrade)February 2005

9Page

Pelco CM9760-CXTA: Setting the Dip SwitchesFigure 6 shows the correct setting of the dip switches on the back of the translator. An Integral DVMS uses the P protocolwith the translator.

1 5432 6 7 8 9 10 11 12 13 14 15 16

1 8OUT IN

1 5432 6 7 8 9 10 11 12 13 14 15 16

1 8OUT IN

OUT FROMDVMS

FIGURE 6

FIGURE 7

Pelco CM9760-CXTA: Multiple TranslatorsTo cascade a second translator off of the first translator, connect the OUT port of the first translator to the IN port of thesecond translator using the provided crossover cable (see Figure 7). Make sure that dip switch 7 is different for the twotranslators.

See the Pelco CM9760-CXTA installation manual for more information.

1 2 3 4 5 6 7 8

Switch Setting Note1 OFF 1–8 32-bit2 OFF 9–16 32-bit3 OFF Protocol4 OFF Unused5 OFF6 ON 4800 baud

7 * Camera inputs: OFF=1–16; ON=17-328 ** Camera type: ON=Spectra; OFF=Intercept

ON

Page 10: 1d45b1 Integral PTZ RS-422 Field

Installing PTZ Cameras on an Integral DVMS (Upgrade)February 2005

10Page

RS-422 converter pin Camera terminal pin

1 RX+

2 RX–

3 TX–

4 TX+

Installing Sensormatic SpeedDome Ultra/DeltaDome II on a DVMSTo upgrade a DVMS for use with a Sensormatic SpeedDome Ultra/DeltaDome II camera, you must wire the camera to the RS-422 converter, connect the converter to the DB-25-to-DB-9 adapter cable, and then plug the cable into the COM port on theDVMS. Pins 1 and 2 on the converter must be wired to the RX+ and RX– pins on the camera, respectively. Pins 3 and 4 onthe converter must be wired to the TX– and TX+ pins on the camera, respectively (see Table 4).

FIGURE 8

TABLE 4On the Setup page inMasterControl, make sureyou select COM1 on the PTZtab for this camera.

1 2 3 4 5 6 7 8OFF OFF ON OFF OFF ON ON ON

Set the switch on the frontof the converter to DCE

Set the switches on the backof the converter as follows:

DVMS

(BLK) 24VACGND

(WHT) 24VAC

(ORG) RX+(GRN) RX-(YEL) TX+(BRN) TX-

Sensormatic SpeedDomeUltra/DeltaDome II I/O Board To additional cameras:

RX+ to RX+ TX+ to TX+RX- to RX- TX- to TX-

Final camera must be terminated

P7

P1

RS-422 DATA*

POWER

Terminationjumper (JW1)

1-2 unterminated2-3 terminated

1

*The Sensormatic RS-422Type Control is supported.

4 3 2 1

D C E

D T E

9VAC/DCpower adapter

DB-25 male to DB-9 femaleadapter cable

External RS-422 converter

ON

Figure 8 illustrates the connection points between the DVMS and the camera. (Drawing not to scale; DVMS drawing may notmatch your particular DVMS model.)

Page 11: 1d45b1 Integral PTZ RS-422 Field

Installing PTZ Cameras on an Integral DVMS (Upgrade)February 2005

11Page

FIGURE 9

TABLE 5

Address Dial 1 Dial 10 Dial 1001 1 0 02 2 0 03 3 0 04 4 0 05 5 0 06 6 0 07 7 0 08 8 0 09 9 0 010 0 1 011 1 1 012 2 1 013 3 1 014 4 1 015 5 1 016 6 1 0

Address Dial 1 Dial 10 Dial 10017 7 1 018 8 1 019 9 1 020 0 2 021 1 2 022 2 2 023 3 2 024 4 2 025 5 2 026 6 2 027 7 2 028 8 2 029 9 2 030 0 3 031 1 3 032 2 3 0

Terminationjumper (JW1)

Addressing dials

1

10

10001

23

4 5 6

78

9

1

1-2 unterminated2-3 terminated

Sensormatic SpeedDome Ultra/DeltaDome II Camera

Sensormatic SpeedDome Ultra/DeltaDome II: Selecting AddressesEach Sensormatic camera connected to a DVMS must have a unique physical address from 1 to 32 that matches the videoinput number it is connected to. To select an address, set the dials on the bottom of the dome drive or camera (see Figure 9).Available addresses are shown in Table 5. Remember to terminate the final camera in each chain using the termination jumperon both the I/O board (see Figure 8) and the camera (see Figure 9).

See the Sensormatic SpeedDome Ultra/DeltaDome II installation manual for more information.

Page 12: 1d45b1 Integral PTZ RS-422 Field

Installing PTZ Cameras on an Integral DVMS (Upgrade)February 2005

12Page

1 2 3 4 5 6 7 8OFF OFF ON OFF OFF ON ON ON

Set the switch on the frontof the converter to DCE

Set the switches on the backof the converter as follows:

RS-422 converter pin Camera terminal pin

1 RX+

2 RX–

On the Setup page inMasterControl, make sureyou select COM1 on the PTZtab for this camera.

DVMS

4 3 2 1

D C E

D T E

9VAC/DCpower adapter

DB-25 male to DB-9 femaleadapter cable

External RS-422 converter

To RX+

To RX-

Vicon Surveyor 2000 To additional cameras:RX+ to RX+RX- to RX-

Final camera must be terminated

S1

S2

TB1

J1

Video out toDVXi or XMUX

Installing Vicon Surveyor 2000 on a DVMSTo upgrade a DVMS for use with a Vicon Surveyor 2000 camera, you must wire the camera to the RS-422 converter, connectthe converter to the DB-25-to-DB-9 adapter cable, and then plug the cable into the COM port on the DVMS. Pins 1 and 2 onthe converter must be wired to the RX+ and RX– pins on the camera, respectively (see Table 6).

Figure 10 illustrates the connection points between the DVMS and the camera. (Drawing not to scale; DVMS drawing maynot match your particular DVMS model.)

FIGURE 10

TABLE 6

ON

Page 13: 1d45b1 Integral PTZ RS-422 Field

Installing PTZ Cameras on an Integral DVMS (Upgrade)February 2005

13Page

Vicon Surveyor 2000: Setting the SwitchesFigure 10 shows the location of the switches used to select the camera address and communication type (RS-422). Set the S2switch as shown in Figure 11.

1 2 3 4 5 6 7 8ON OFF OFF OFF OFF OFF OFF OFF

FIGURE 11ON S2

TABLE 7

Examples

ON

ON

ON

Address S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 S1-7 S1-81 ON OFF OFF OFF OFF OFF OFF OFF2 OFF ON OFF OFF OFF OFF OFF OFF3 ON ON OFF OFF OFF OFF OFF OFF4 OFF OFF ON OFF OFF OFF OFF OFF5 ON OFF ON OFF OFF OFF OFF OFF6 OFF ON ON OFF OFF OFF OFF OFF7 ON ON ON OFF OFF OFF OFF OFF8 OFF OFF OFF ON OFF OFF OFF OFF9 ON OFF OFF ON OFF OFF OFF OFF10 OFF ON OFF ON OFF OFF OFF OFF11 ON ON OFF ON OFF OFF OFF OFF12 OFF OFF ON ON OFF OFF OFF OFF13 ON OFF ON ON OFF OFF OFF OFF14 OFF ON ON ON OFF OFF OFF OFF15 ON ON ON ON OFF OFF OFF OFF16 OFF OFF OFF OFF ON OFF OFF OFF17 ON OFF OFF OFF ON OFF OFF OFF18 OFF ON OFF OFF ON OFF OFF OFF19 ON ON OFF OFF ON OFF OFF OFF20 OFF OFF ON OFF ON OFF OFF OFF21 ON OFF ON OFF ON OFF OFF OFF22 OFF ON ON OFF ON OFF OFF OFF23 ON ON ON OFF ON OFF OFF OFF24 OFF OFF OFF ON ON OFF OFF OFF25 ON OFF OFF ON ON OFF OFF OFF26 OFF ON OFF ON ON OFF OFF OFF27 ON ON OFF ON ON OFF OFF OFF28 OFF OFF ON ON ON OFF OFF OFF29 ON OFF ON ON ON OFF OFF OFF30 OFF ON ON ON ON OFF OFF OFF31 ON ON ON ON ON OFF OFF OFF32 OFF OFF OFF OFF OFF ON OFF OFF

Each Vicon Surveyor 2000 camera connected to a DVMS must have a unique physical address from 1 to 32 that matches thevideo input number the camera is connected to. To select an address on Vicon Surveyor 2000, set the S1 switch on thebottom of the camera. Use the settings shown in Table 7. The final camera in a Vicon Surveyor 2000 chain does not have tobe terminated.

See the Vicon Surveyor 2000 installation manual for more information.