36
Consistency Presentation 3. Mechanical transmitters: Smart-Pulp Level1

19.Metso Blade Consistency Presentation

Embed Size (px)

Citation preview

Page 1: 19.Metso Blade Consistency Presentation

Consistency Presentation

3. Mechanical transmitters: Smart-PulpLevel1

Page 2: 19.Metso Blade Consistency Presentation

Content

Measuring principleConstructionSensorsCalibrationInstallation

Page 3: 19.Metso Blade Consistency Presentation

Content

Measuring principleConstructionSensorsCalibrationInstallation

Page 4: 19.Metso Blade Consistency Presentation

SMART-PULP, Model M2, 12/1998

Page 5: 19.Metso Blade Consistency Presentation
Page 6: 19.Metso Blade Consistency Presentation

B Softwood,Bleached

D Hardwood,Bleached

% Cs

grams

800

600

400

200

0

1000

1200

1.5 2.52.0 3.53.0 4.0 5.04.5

1400

1600

B

D

Fiber Length Affects Shear Force Transmitters

Page 7: 19.Metso Blade Consistency Presentation

Optimiced blade design / Flow compensation

Page 8: 19.Metso Blade Consistency Presentation

Good results in international tests

Page 9: 19.Metso Blade Consistency Presentation

SummaryShear force measurement principle

• Fiber consistency measurement• Flow compensation• Test results available

Page 10: 19.Metso Blade Consistency Presentation

Content

Measuring principleConstructionSensorsCalibrationInstallation

Page 11: 19.Metso Blade Consistency Presentation

F ´

SMART-PULP

Electronics

Damping oilPiezoresistiveforce sensor

Sensitivebearing

Processtemperatureprope

Metal diaphagm

Overload protection

Page 12: 19.Metso Blade Consistency Presentation

Mechanical construction

Oil expansiondiaphragm

Damping oil

Connecting wire

Piezoresistiveforce sensor

A small gap foroverload protection

Mechanical "fuse"

Replaceableconical pin

Taper bush

Metal diaphragm

Periphery O-rings Temperature probe

Bearing shaft

Page 13: 19.Metso Blade Consistency Presentation

Metal diphagm

O-Rings

SMART-PULP: Highly sensitive measurement

• Hysteresis does not disturb the measurement!

• Repeatability 0.01 N = 0.005 %Cs to 0.015 %Cs

Page 14: 19.Metso Blade Consistency Presentation

Temperature-compensated measurement• Electronics

temperature• Sensor

temperature• Process

temperature

Page 15: 19.Metso Blade Consistency Presentation

High pressure and temperature limits

  Process pressure: max 25 bar  Process temperature: max 120 °C

Page 16: 19.Metso Blade Consistency Presentation

SummaryReliable construction

• High sensitivity• Resists high vibrations• Maximum process temperature 120 deg.

C• Maximum process pressure 25 bar• No regular maintenance needed

Page 17: 19.Metso Blade Consistency Presentation

Content

Measuring principleConstructionSensorsCalibrationInstallation

Page 18: 19.Metso Blade Consistency Presentation

SMART-PULPSensors

LL

0 5 10 15

UL JL LS GL RL HL WS

0 5 10 15

Cs%

Long Fibers

Low Consistency

Fiberglass-reinf. pipe

Mechanical pulp CSF>200

Short Fiber

High Consistency

Recycled fiber pulp

Short Fiber

Page 19: 19.Metso Blade Consistency Presentation

Consistency Transmitter Selection : Quick Guide

LC 1 0 0 S MA R T -P U LP MC A

G ra d e U L LL LS R L G L W S *) J L H L

S W 0 . . . 1 1 . . . 2 2 . . . 5 ,5 (2 . . . 5 ) (2 . . . 6 ) 2 . . . 6 5 , 5 . . . 1 6 0 . . . 4 0S o ftwo o d 0 .. .1 ,2 0 ,7 .. .3 1 ,5 .. .6 (1 ,5 .. .6 ) (1 ,7 .. .7 ) 1 ,5 ...6 4 .. .1 6 0 .. .4 0

HW 0 . . . 1 , 4 1 , 2 . . . 2 (2 . . . 5 ) 2 . . . 5 2 , 5 . . . 6 2 . . . 6 6 . . . 1 6 0 . . . 4 0H a rd wo o d 0 .. .1 ,5 1 ...3 (1 ,8 .. .5 ) 1 ,7 ...6 .5 1 ,8 ...7 ,5 1 ,8 ...6 5 .. .1 6 0 .. .4 0

G W 0 . . . 1 , 5 1 , 2 . . . 3 2 , 5 . . . 4 , 5 4 . . . 7 5 . . . 1 6 0 . . . 4 0G ro u n d wo o d 0 .. .1 ,7 1 ...4 1 ,7 .. .5 1 ,8 ...7 ,5 0 .. .4 0

R MP ,TMP 0 . . . 1 , 2 1 . . . 2 2 . . . 4 , 5 2 . 5 . . . 6 , 5 6 . . . 1 6 0 . . . 4 0C S F <2 0 0 0 .. .1 ,5 0 ,7 .. .3 1 ,7 ...6 .5 1 ,5 ...6 ,5 5 .. .1 6 0 .. .4 0

R MP ,TMP 0 . . . 1 , 2 1 . . . 2 2 . . . 4 4 . . . 6 6 . . . 1 6 0 . . . 4 0C S F >2 0 0 0 .. .1 ,5 0 ,7 .. .3 1 ,5 .. .5 ,5 3 .. .6 (1 ,5 …6 ) 4 .. .1 6 0 .. .4 0

CTMP 0 . . . 1 , 2 1 , 2 . . . 2 2 . . . 5 4 . . . 6 5 . . . 1 6 0 . . . 4 0

0 .. .1 ,5 0 ,7 .. .3 1 ,5 .. .5 ,5 3 .. .6 (1 ,5 .. .5 ) 4 .. .1 6 0 .. .4 0

R e c yc le d 0 . . . 1 , 2 1 , 2 . . . 4 2 . . . 6 2 , 5 . . . 7 2 . . . 8 6 . . . 1 6 0 . . . 4 0

0 .. .1 ,5 1 ...5 1 ,7 .. .8 1 ,8 ...8 2 .. .8 5 .. .1 6 0 .. .4 0

OCC 0 . . . 1 , 2 1 , 2 . . . 2 2 . . . 6 2 . . . 7 2 . . . 8 6 . . . 1 6 0 . . . 4 0R e c yc le d 0 .. .1 ,5 1 ...3 1 ,5 .. .7 1 ,7 ...8 2 .. .8 5 .. .1 6 0 .. .4 0

*) Use WS type for unscreened recycled fibre pulps

Page 20: 19.Metso Blade Consistency Presentation

27 %

50 %

2 %

2 %

1 % 5 %4 % 9 %

LL RL LS HL UL GL JL WS

Smart-Pulp sales by sensor type

Page 21: 19.Metso Blade Consistency Presentation

SummaryWide application range

• Possible to measure all pulp grades• Consistency range: 0.7 - 2 to 16 %Cs• Velocity range: 0.1 - 0.4 to 5 m/s

Page 22: 19.Metso Blade Consistency Presentation

Content

Measuring principleConstructionSensorsCalibrationInstallation

Page 23: 19.Metso Blade Consistency Presentation

SMART-PULP Calibration

• The transmitter's memory circuits contain calibration curves adapted for all known unmixed pulps and all sensor models.

• Easy calibration. You just select the sensor type, pulp grade and mounting position, and check the consistency level at a single point.

• Compensation for ash is possible. • For unknown pulp types or pulp mixes you can create their own

curves or adapt a standard calibration curve through two points

Page 24: 19.Metso Blade Consistency Presentation

Main menu

Consistency %

MilliAmps

% Of span

Shear force

Sensor temp.

Process temp

Housing temp

% Cs

mA

%

G or N

S F or C

P F or C

H F or C

RECIPE n

ASH %

LOWER RA NEW RECI MESSAGE(enter) (enter) (enter) (enter)

UPPER RA DAMPING

LANGUAGE UNITS

MOUNTING

HART-ADD BLADE TY

TMTRTYPE

PASSWORD

TAG

TMTRVERS

SAMPLING LABORATO SP.GRADE

DIG INPT

TRIM-F MA-LOCK

TRIM-MA

COMMUNIC

MEASURE CONFIGUR CALIBRAT DIAGNOST

(enter)

(enter)

(enter)

(enter)

(enter)

SAVE OK?

(esc) Return to previous option or menu level(enter) Accept (OK) Moving in menu or changing a parameter valueSAVE OK?

ALRM TYPE

Page 25: 19.Metso Blade Consistency Presentation

You can make the selection as follows:

You can pre-select up to eight (8) calibration curves included in Smart-Pulp's memory circuits:

• using SMART-PULP operator terminal or

• through the HART terminal or • through three binary inputs

Page 26: 19.Metso Blade Consistency Presentation

Support for sampling

  Internal average value and standard deviation calculation during sampling. Sampling controlled with pushbuttons or with a switch on the sampler.

NOVE with binary switch

Page 27: 19.Metso Blade Consistency Presentation

SummaryWide application range

• Easy accurate one or two point calibration• Up to 8 different recipe calibrations possible• NOVE sample valve supported sampling• HART communication• Linear output• PC software for real time communication:

Consistency Advisor

Page 28: 19.Metso Blade Consistency Presentation

Content

Measuring principleConstructionSensorsCalibrationInstallation

Page 29: 19.Metso Blade Consistency Presentation

Easy to install or replace

• Easy installation

• Calibration through operator terminal or -

• hand-held terminal.

Page 30: 19.Metso Blade Consistency Presentation
Page 31: 19.Metso Blade Consistency Presentation

SMART-PULP Installation into the pipes

Page 32: 19.Metso Blade Consistency Presentation

SMART-PULP Installation into the pipes

Shafts of thevalve and pump parallel

Page 33: 19.Metso Blade Consistency Presentation

ASPE- Mounting pipe element

eliminates process disturbances

• Feature / User advantage: The ASPE mounting pipe element comprises the following components:

- 1. Flow straightener plates Ensures laminar flow upstream of transmitter. Transmitter can be installed relatively close to pump (small measurement lag).

- 2. Impact guards on both sides of transmitter Lumps that form especially during shutdown will be broken to prevent transmitter damage.

- 3. Mounting coupling pre-welded on element Coupling´s correct orientation is ensured.

FACILITATES PIPEWORK DESIGN, INSTALLATION AND MAINTENANCE.

ENSURES GOOD RESULTS.

Page 34: 19.Metso Blade Consistency Presentation
Page 35: 19.Metso Blade Consistency Presentation

SummaryLow installation cost

• Cost effective installation• Quick and easy installation• Be careful when choosing the right spot for

the transmitter• Mounting pipe for difficult installations

Page 36: 19.Metso Blade Consistency Presentation

SummarySmart-Pulp Sales Arguments• High sensitivity and low hysteresis due to diaphragm sealing and

piezoresistive sensor• Flow compensated blade selection, • Over 35,000 blade transmitter installations world-wide• Single or two point smart calibration• High performance and price advantage. Test reports.• Quick and easy installation• Excellent vibration resistance• No regular maintenance needed.• HART communication.• Linear output.• Separate operator terminal