    Serial Line connection to hiT 7070 / 7050 HiT7070 / hiT7050 / TNMS-CT 2.0

    Siemens AGICN CP E NP JHofmannstr. 5181359 Munich

    NCC Hotline:Tel.: +89 / 722-44666Fax: +89 / 722-62747E-Mail: [email protected]: 201862007.doc

  • SIEMENSReleasesThis document concerns the serial connection ("F" interface) to hiT 7070 and 7050 releases

    1.02 1.1 2.0

    NOTE: Release 1.0 of hiT 7050 does not provide "F" interface support.

    SymptomsIn some cases it is not possible to connect from TNMS-CT 2.0 or higher to Surpass hiT 7070/7050 using the serial line.

    Problem Description

    Surpass 7050 serial cableThe serial cable used to connect to Surpass hiT 7050 must have a particular pin assignment. Some commercially available "null-modem" cables will work and others will not work, depending on the pin connection of the cable.

    WorkaroundUse a serial "null-modem" cable that has only pins 2 and 3 (RX and TX) connected (cross), and pin 5 for ground. All other pins are not connected, as shown in the diagram below:

    DB-9 femaleview of the soldering side

    1 2 3 4 5

    6 7 8 9 12345

    6789

    DB-9 femaleview of the soldering side

    Ordering number for Siemens cableThere is a Siemens code for the "official" cable for hiT 7050. V42256-R703-A18-1 TPY R0This cable has the following connections:

    Pin Pin1 ------------ 12 ------------ 33 ------------ 24 ------------ 45 ------------ 56 ------------ 67 ------------ 78 ------------ 8

    Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

    Issue Modif. Note

    Date Name SIEMENS AGInformation and Communication Networks

    TNMS-CT 2.0 Page2/14Document: 201862007.doc All rights reserved

  • SIEMENSThis means, pins 2 and 3 are connected crossed, other pins are connected straight. Pin 9 is not used.The connections are shown in the diagram below.

    view of the soldering side

    9876

    51 2 3 4

    12345

    6789

    view of the soldering side

    hiT 7070/ 7050Ordering number for Lindy cable

    There have also been successful tests for serial connection to hiT using a commercial "Lindy" brand cable.The ordering number from Lindy for this cable is 31578.

    Pins 4 and 9 are not connected. The connections are shown in the diagram below:

    DB-9 femaleview of the soldering side

    1 2 3 4 5

    6 7 8 9 12345

    67

    89

    DB-9 femaleview of the soldering side

    More information available under http://www.lindy.com.Using this cable we have successfully tested the "F" interface connection to hiT 7070 as well as 7050.

    Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

    Issue Modif. Note

    Date Name SIEMENS AGInformation and Communication Networks

    TNMS-CT 2.0 Page3/14Document: 201862007.doc All rights reserved

    Pin Pin1/6/8 ------------ 7

    2 ------------ 33 ------------ 25 ------------ 57 ------------ 1/6/8

  • SIEMENS

    Appendix: Setting up the serial connection.

    Procedure from User Manual

    Attached the procedure extracted from the TNMS-CT V1.0 User Manual (UMN) Chapter 3.6.1.

    chapter361.doc

    If the serial connection in TNMS-CT is already set, check that it is properly configured by comparing the settings shown in the user manual in point 7 of chapter 3.6.1 (see the screenshots in the document attached above).

    If the serial connection does not work (fails when trying to connect), it is also recommendable to check the following:

    1. MPU-F properties:

    Register General

    Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

    Issue Modif. Note

    Date Name SIEMENS AGInformation and Communication Networks

    TNMS-CT 2.0 Page4/14

  • SIEMENS

    Register "Options"

    Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

    Issue Modif. Note

    Date Name SIEMENS AGInformation and Communication Networks

    TNMS-CT 2.0 Page5/14

  • SIEMENS

    Register "Security"

    Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

    Issue Modif. Note

    Date Name SIEMENS AGInformation and Communication Networks

    TNMS-CT 2.0 Page6/14

  • SIEMENS

    Register: Networking

    PPP-Settings:

    Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

    Issue Modif. Note

    Date Name SIEMENS AGInformation and Communication Networks

    TNMS-CT 2.0 Page7/14

  • SIEMENS

    TCP/IP-properties:

    Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

    Issue Modif. Note

    Date Name SIEMENS AGInformation and Communication Networks

    TNMS-CT 2.0 Page8/14

  • SIEMENS

    2. OSI Protocol settings in TNMS-CT

    notice the "Local IP Address" must be 127.0.0.1 for the serial connection to work.

    Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

    Issue Modif. Note

    Date Name SIEMENS AGInformation and Communication Networks

    TNMS-CT 2.0 Page9/14

  • SIEMENS

    3. DCN Management in TNMS-CT

    From the main TNMS-CT menu choose

    Configuration -> DCN management

    In this window the first item is the Serial Line Server. Clicking on the server icon displays the four Serial Line Server Channels that are available in TNMS-CT. hiT 7070 and 7050 are QST V2 Network Elements.

    Here the NE ("QST V2 Serial Line NE") must exist under the QST V2 Serial Line Channel, as shown in the figure above.

    Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

    Issue Modif. Note

    Date Name SIEMENS AGInformation and Communication Networks

    TNMS-CT 2.0 Page10/14

  • SIEMENSSettings QST V2 Serial Channel:

    Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

    Issue Modif. Note

    Date Name SIEMENS AGInformation and Communication Networks

    TNMS-CT 2.0 Page11/14

  • SIEMENS

    The NE must have the following properties (click on the item "QST V2 Serial Line NE" with the right-hand mouse button and select the item "Properties")

    Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

    Issue Modif. Note

    Date Name SIEMENS AGInformation and Communication Networks

    TNMS-CT 2.0 Page12/14

  • SIEMENS

    Register: General

    The ID Name need not be changed. It is not mandatory to add any data in this window.

    Register: Security

    For serial connection with TNMS-CT the following data must be entered

    User: LCTPassword : "NEPASSWORD" (all capital letters)

    Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

    Issue Modif. Note

    Date Name SIEMENS AGInformation and Communication Networks

    TNMS-CT 2.0 Page13/14

  • SIEMENS

    Register: QST

    IP Address must be 195.0.0.1T-Selector must be QST

    After this press "Apply" to make the changes permanent.

    Successful connection

    After a successful connection the DCN management must show the NE under the " QST V2 Serial Line Channel" in status "running" (see DCN Management window above). In the Network View the NE must also be shown with a green icon, as shown in the figure below:

    Clicking on the icon with the right-hand mouse button open the Element Manager for operation.

    Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

    Issue Modif. Note

    Date Name SIEMENS AGInformation and Communication Networks

    TNMS-CT 2.0 Page14/14