20
Operating Instructions 196 electronic IP65 196 M electronic IP65 EN

196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

Embed Size (px)

Citation preview

Page 1: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

Operating Instructions196 electronic IP65

196 M electronic IP65EN

Page 2: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

196 / 196 M electronic IP65

1

en

The STABILA 196 electronic IP65 is an electronic spirit level with 2 digital displays for quickly and easily measuring inclinations and angles.

If you still have any questions after reading the operating instructions, feel free to call our hotline:

0049 / 63 46 / 3 09 - 0

Equipment and functions:• vertical vial(s) for vertical levelling, in reverse position too• horizontal vial for horizontal levelling, in reverse position too• electronic module with 2 digital displays for accurately

determining inclinations and angles

Operating Instructions

Page 3: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

196 / 196 M electronic IP65

2

enComponents of the unit

Buttons: On/OffOperating mode selectionReferenceMeasurement memory Lighting Acoustic signalCalibration Button lock

1. 2 Displays 2. Battery compartment lid3. Magnet (196 M electronic IP65)4. Vials - vertical and horizontal5. Removable, shock-absorbing end caps6. Anti-slip stopper7. Electronic module

- dust-proof and waterproof in accordance with IP 65

IP 65IP 65

Page 4: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

196 / 196 M electronic IP65

3

en

2x 1.5V alkaline

AA, LR6, Mignon

MN 1500

Unscrew battery compartment lid on rear, insert new batteries according to symbol in battery compartment.Suitable rechargeable batteries can also be used.

LCD: low battery charge - insert new battery

Dispose of used batteries at suitable collection points - not with household waste. Do not leave in unit! Remove the batteries if you do not intend to use the unit for some time!

Insert batteries / Battery replacement

Page 5: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

196 / 196 M electronic IP65

4

en

After switching on, an automatic self-test is carried out. All the display's segments are shown. After the end of the test, the version number S x.xx of the measurement program is briefly displayed and the saved automatic switch-off time of 1/8 or 2 hours displayed. An acoustic signal indicates that the unit is ready for operation. The display shows the angle measured in the set unit of measurement.

Commissioning

test

off

Software Version

Page 6: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

196 / 196 M electronic IP65

5

enAutomatic display inversion

The two displays are inverted for overhead measurements so they are always legible.

Alignment guides

Arrows in the display show which way to turn the spirit level to the horizontal (-15°/0 °/+ 15°) or vertical (+75°/90°/-75°). The acoustic alignment guide is activated / deactivated using the "Acoustic signal" button. If the acoustic signal is activated, the tone sequence speeds up as the 0° or 90° position is approached in a range of ± 2° to the horizontal or vertical. A change in the pitch indicates that these positions have been exceeded. A continuous tone confirms the precise point

at which the horizontal / vertical is reached. This is also indicated on the display with 2

"centre display" bars.

The electronic spirit level can also be aligned using the vial.

Page 7: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

196 / 196 M electronic IP65

6

en

0,05˚

0,1˚

The unit of measurement is set by pressing the MODE button several times.

° Rough: Display in 0.1° steps

° Fine: Display in 0.05° steps

%: Display in 0.1 % steps

mm/m: Display in 1 mm/m steps

in/ft decimal: Display in 0.01 in/ft steps

in/ft fraction: Display in 1/8 in/ft steps

The set unit of measurement is retained after the unit is switched off.

Setting the unit of measurement

MODE

Page 8: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

196 / 196 M electronic IP65

7

en

The REF button can be used to select any set angle as 0° reference. The angle details now displayed relate to this reference angle. The display flashes in this setting.

The original reference angle value is displayed for 2 seconds by briefly pressing the REF button.

The reference angle is deleted by:• Pressing and holding (≥ 3 sec) the REF button

If the button lock is active, this must be disabled first.• Switching off • The automatic switch-off function

The zero position again refers to the calibrated setting.

The alignment selected for the electronic spirit level must not be changed during the reference function!

Reference angle - freely selectable zero position

+5°(= 25° )

0°(= 20° )

20°( + 5° )

RESETREFERENCE

REFERENCE20°

3 sec

1x

1x

1x

3 sec

2 sec

Page 9: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

196 / 196 M electronic IP65

8

en

Briefly pressing the "Lighting" button switches the display lighting on for approx. 60 seconds. Pressing and holding the "Lighting" button switches the lighting permanently on or off. The pressing of this button is confirmed by an acoustic signal.

Lighting1x

1x

1x

on = 60 sec

on = ∞

Button lock Pressing and holding ( ≥ 3 sec ) the "Key" button locks the

Operating mode selection

Reference

Measurement memory

Calibration

buttons. The button lock remains active after switching the unit off and back on again! Pressing and holding the "Key" button disables the button lock. The pressing of this button is confirmed by an acoustic signal.

1x

1x

5 sec

Page 10: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

196 / 196 M electronic IP65

9

en

1x

1x

HOLD

Measurement memory The current measurement can be saved by pressing the HOLD button. The arrows and the "centre display" bars flash. The measurement is displayed continuously. Close to 0° and 90° the arrows flash to indicate direction.The saved measurement is deleted by again pressing the HOLD button or switching the unit off.

Page 11: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

196 / 196 M electronic IP65

10

enSetting switch-off time

The electronic spirit level is switched off automatically if not used or moved for a long while. Pressing the "Lighting" and "Acoustic signal" buttons at the same time allows the automatic switch-off time to be changed from 1/8 hours (approx. 7.5 minutes) to 2 hours. The set switch-off time is retained after the unit is switched off and is displayed briefly when it is switched on again.

81 h

= 7.5 min

2h21

1x

1x

Acoustic signal

The acoustic alignment guide is activated / deactivated using the "Acoustic signal" button.

Page 12: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

196 / 196 M electronic IP65

11

enTilt function

The measuring surfaces of the electronic spirit level should be positioned precisely for all measurement work. If positioned at too great an angle, the tilt function prevents incorrect measurements. The display doesn't then show any measurements.

5° 5°

5° 5°

Page 13: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

196 / 196 M electronic IP65

12

en

0° - 0.05° = OK

> 0.05° CAL.

Accuracy checkTo prevent incorrect measurements, before starting work or after hard knocks, large changes in temperature and a change of user, the accuracy must always be checked.

1. Switch on the electronic spirit level. Use the vial to accurately align the unit to a wall, for example, until the vial bubble is in the middle between the vial rings.

2. Wait 10 seconds. If the value displayed is > 0.05°, the electronic spirit level must be recalibrated.

If mainly used for vertical measurements, the accuracy check can also be undertaken with the vertical vial.

10 sec

Page 14: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

196 / 196 M electronic IP65

13

enCalibration

1. Switch on the electronic spirit level. Use the vial to accurately align the unit to a wall, for example, until the vial bubble is in the middle between the vial rings. If mainly used for vertical measurements, the calibration can also be undertaken with the vertical vial.

2. Hold the electronic spirit level in this position and press the CAL button. The CAL display shows calibration mode.

3. Calibration starts when the CAL button is pressed again.

CALIBRATE

1x

1x

1x

Newly calibrated value withdeviation of ≥ 1° from factory setting

Recalibrate spirit level

Vibration during calibration

Recalibrate spirit level

Calibration completed successfully

Spirit level ready

The reverse test checks the calibration.

Angle ≤ 0.1° to normal position

Spirit level ready

1x

5 sec

180°

Page 15: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

196 / 196 M electronic IP65

14

enCalibration in 4 positions:

Calibration in 4 positions is needed if the following is displayed:1. The reverse test angle is ≥ 0.1° to the normal position

--> too great a deviation.2. Change in internal reference 3. Change in temperature since last calibration. The electronic spirit level is calibrated in 4 measuring positions consecutively, turning 90° / 180° each time.

Calibration in 4 positions: Step 1 Press CAL and MODE buttons at the same time. Align the electronic spirit level accurately against a wall and press the CAL button to confirm.

Only the 1st calibration step is performed with the vial.

1x

Flashing segments indicate the positions still to be calibrated.

Non-flashing segments indicate the positions already calibrated.

Page 16: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

196 / 196 M electronic IP65

15

en

180°

1x

Calibration in 4 positions: Step 2 The electronic spirit level is turned 180° and aligned using the arrows displayed. The electronic spirit level is aligned horizontally using the arrows displayed. The 2 "centre display" bars indicate the precise position at which the horizontal is reached. Confirm with the CAL button. Flashing segments indicate the positions still to be calibrated.

Non-flashing segments indicate the positions already calibrated.

Page 17: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

196 / 196 M electronic IP65

16

en

1x

90°

Calibration in 4 positions: Step 3 The electronic spirit level is turned 90° and aligned vertically using the arrows displayed. The 2 "centre display" bars indicate the precise position at which the vertical is reached. Confirm with the CAL button. The flashing segment indicates the position still to be calibrated.

Non-flashing segments indicate the positions already calibrated.

Page 18: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

196 / 196 M electronic IP65

17

en

1x

180°Calibration in 4 positions: Step 4

The electronic spirit level is turned 180° and aligned vertically using the arrows displayed. The 2 "centre display" bars indicate the precise position at which the vertical is reached. Confirm with the CAL button. "rdy" display: Calibration in 4 positions successfully completed!

Page 19: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

196 / 196 M electronic IP65

18

enMaintenance and upkeep

The electronic spirit level is a precision instrument and should therefore be handled with care. Display window: Dirty window glass impairs the optical function. Only clean with a soft cloth, a little water or, if required, a mild detergent! Casing: Clean the unit with a damp cloth. • Do not use solvents or thinners!• Do not immerse the unit in water • Do not unscrew the electronic spirit level!

Transport and storage• Remove the batteries if you do not intend to use the unit for some time!• Do not store the unit when damp! • Allow the unit and carry case to dry first if

necessary.

Recycling programme for our EU customers In accordance with WEEE rules, STABILA offers to dispose of electronic products at the end of their useful service life. For more information call: 0049 / 6346 / 309-0

STABILA warranty declarationIn addition to the statutory rights of buyers, which are not limited by this warranty, STABILA guarantees that the unit is free from defects and has assured features in the event of material or manufacturing defects for aperiod of 24 months from the date of purchase. Any defects / errors willbe remedied at our discretion through reworking or replacement. STABILA will not assume liability for further claims. Defects resulting from improper handling (e.g. damage due to application of serious force, operation with incorrect voltage / current type, use of unsuitable power source) and unauthorised modifications to the unit by the buyer or a third party shall invalidate the warranty. STABILA does not provide a warranty for natural signs of wear and minor defects that do not affect the operation of the unit. Any warranty claims should be made through your dealer and be accompanied by your sales receipt, completed certificate of warranty (see last page of operating instructions) and the unit itself.

Certificate of warranty for 196 / 196 M electronic IP65

Customer:

Address: Date of purchase: Dealer (stamp, signature):

Technical dataAccuracy:Electronic module 0° + 90° : ± 0.05° 1° .... 89° : ± 0.2°

Spirit level in normal position: 0.5 mm / m = 0.029° in reverse position: 0.5 mm / m = 0.029°

Batteries : 2 x 1.5 V alkaline, size Mignon, AA, LR6Operating life : ≥ 150 hours Operating temperature range: -10 °C to +50 °CStorage temperature range: -20 °C to +65 °C Protection class: IP 65Subject to technical modifications. 2015

Page 20: 196 electronic IP65 196 M electronic IP65 - STABILA · PDF fileAn acoustic signal indicates that the unit is ready for ... Display in 0.1 % steps mm/m: ... 196 / 196 M electronic IP65

STABILA MessgeräteGustav Ullrich GmbHP.O. Box 13 40 / D-76851 AnnweilerLandauer Str. 45 / D-76855 AnnweilerTel.: + 49 63 46 309 - 0Fax: + 49 63 46 309 - 480E-mail: [email protected]

STABILA Inc.

332 Industrial DriveSouth Elgin , IL 601771.800.869.7460

www.stabila.com

USACanada