    Upon completion of this course, you will be

    able to:

    Explain the menu of iManager T2000 forEthernet Services

    Describe the process of configuring

    Ethernet Services on the T2000

    Learn how to configure Ethernet Services

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    3/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 2

    Chapter 1 The Basic Concepts

    Chapter 2 The EPL Service Configuration

    Chapter 3 The EPLAN Service Configuration

    Chapter 4 The EVPL Service Configuration

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    4/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 3

    Tag flag is used to identify the type of packets. Three types of TAG flags

    are available: tag aware, access, and hybrid.

    Tag Aware: When the port is set to be tag aware, the port transmits

    the packets with the Tag flag transparently and discards those

    without the Tag flag

    Access: When the port is set to be access, the port attaches a Tag

    flag to the packets without Tag flag according to its VLAN ID and

    discards those with the Tag flag.

    Hybrid: When the port is set to be hybrid, the port can processpackets regardless of the Tag flag and attach a Tag flag to the

    packets without the Tag flag according to its VLAN ID.

    Tag flag:

    Parameters for the Ethernet interface

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    5/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 4

    Parameters for the Ethernet interface

    Tag flag Untag flag

    Tag aware (In) Transmit transparently discard

    Tag aware (Out) Transmit transparently

    Access (In) discard attach a Tag flag (default Vlan)

    Access (Out) Delete the Tag flag (default Vlan)

    Hybrid (In) Transmit transparently attach a Tag flag (default Vlan)

    Hybrid (Out)If Vlan is the same, delete the Tag flag,

    otherwise transmit transparently

    PortPackets

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    6/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 5

    Parameters for the Ethernet interface

    VLAN ID:

    VLAN ID of the port (MAC or VCTRUNK).

    Working mode:

    It can be set to auto-negotiation, 10 Mbit/s half/full-duplex,100 Mbit/s half/full-duplex or 1 Gbit/s full-duplex. The

    Ethernet interfaces of the interconnected equipment shouldwork under the same fixed working mode; otherwise, thepacket may be lost and the rate may decrease, or theservice may be completely interrupted upon large volume oftraffic.

    Port type:

    There are two types: P and PE. Provider edge (PE) is themarginal port of the service provider. Provider (P) is thecore network port of the service provider. Port type isneeded when configuring EVPL and EVPLAN services.

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    7/88HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 6

    Parameters for the Ethernet interface

    LCAS enable:

    Maximum packet length:

    Whether to enable LCAS.

    Set this item for the external port, 1522 bytes by default.

    Mapping protocol:

    It is preferable to select the default- GFP mapping protocol.

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    8/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 7

    Reference: G.8010 /Y.1306 (G.ethna),

    G.8011 (G.ethsrv),

    G.8012.1 (G.eota.1).

    Ethernet Services Types EPL: Ethernet Private Line Service.

    EPLAN: Ethernet Private LAN Service .

    EVPL: Ethernet Virtual Private Line Service.

    EVPLAN: Ethernet Virtual Private LAN Service.

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    9/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 8

    Chapter 1 The Basic Concepts

    Chapter 2 The EPL Service Configuration

    Chapter 3 The EPLAN Service Configuration

    Chapter 4 The EVPL Service Configuration

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    10/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 9

    For EPL Service, there are three types:

    the Point-to-Point EPL Service

    the MAC Shared EPL Service

    the VCTRUNK Shared EPL Service

    Configuring the EPL Service

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    11/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 10

    Configuring the EPL Service

    Configuring the Point-to-Point EPL Service:

    Engineering Requirements

    Engineering Planning

    Configuration Process

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    12/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 11

    Configuring the EPL Service

    Configuring the Point-to-Point EPL Service:

    User Service requirement Source station Sink station Bandwidth

    A Point-to-point NE1 NE5 10 Mbit/s

    B Point-to-point NE1 NE5 40 Mbit/s

    STM-16two-fiberbidirectional MSP ring

    T2000

    STM-4two-fiber

    bidirectional non-protection chain

    NE1

    NE2

    NE3

    NE4

    NE5

    Engineering Requirements

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    13/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 12

    Configuring the EPL Service

    Configuring the Point-to-Point EPL Service:

    Engineering Planning

    Step 1: Networking Diagram

    Step 2: Board Information of Each NE

    Step 3: Service Configuration Diagram of Each NE

    Step 4: Timeslot Allocation Diagram

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    14/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 13

    A B

    STM-16 two-fiberbidirectional MSP ring

    T2000

    STM-4 two-fiberbidirectional non-protection chain

    NE1

    NE2

    NE3

    NE4

    NE5

    A B

    VC-Trunk

    MAC1 MAC2

    MAC1 MAC2

    Company A Service

    Company B Service

    Configuring the EPL Service

    Step 1: Networking Diagram

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    15/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 14

    Board layout of NE1

    Configuring the EPL Service

    Step 2: Board Information of Each NE

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    16/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 15

    Board layout of NE5

    Configuring the EPL Service

    Step 2: Board Information of Each NE

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    17/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 16

    VC4-4:VC12-1~VC12-5

    MAC1

    A10M

    40M

    B

    VCTRUNKMAC

    MAC2

    VCTRUNK1

    VCTRUNK2

    VC-4-1:VC-3-1

    SDHVC4-4:VC12-1~VC12-5

    VCTRUNK

    VCTRUNK1

    VCTRUNK2

    VC-4-1:VC-3-1

    MAC1A

    10M

    40M

    B

    MAC

    MAC2

    NE1NE5

    Service configuration diagram

    Configuring the EPL Service

    Step 3: Service Configuration Diagram of Each NE

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    18/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 17

    Configuring the EPL Service

    Service Attribute A B

    Source NE NE1 NE1

    Source board - port 13-N1EFS4-1 13-N1EFS4-2

    Source timeslot VC4-4: VC12-1VC12-5 VC4-1: VC3-1

    Source VCTRUNK VCTRUNK1 (Tag aware) VCTRUNK2 (Tag aware)

    Working mode of source MAC port Auto negotiation Auto negotiation

    TAG flag of source MAC port Access Access

    VLAN ID of source MAC port 1 2

    Bound bandwidth 5 x VC-12 1 x VC-3

    Sink NE NE5 NE5

    Sink board - port 15-N1EFS4-1 15-N1EFS4-2

    Sink timeslot VC4-4: VC12-1VC12-5 VC4-1: VC3-1

    Sink VCTRUNK VCTRUNK1 (Tag aware) VCTRUNK2 (Tag aware)

    Working mode of sink MAC port Auto negotiation Auto negotiation

    TAG flag of sink MAC port Access Access

    VLAN ID of sink MAC port 1 2

    Step 3: Service Configuration Diagram of Each NE

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    19/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 18

    Configuring the EPL Service

    Timeslot

    NE2Station NE3 NE4NE1

    12-SL16-1

    NE1

    7-SL16-112-SL16-1 7-SL16-112-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1

    Forward

    NE5NE4

    13-SL4-1 7-SL4-1

    Ring

    Chain

    Add/Drop

    VC-4-313-EFS4: VC4-4

    VC-12: 1-5

    VC-4-413-EFS4: VC-4-1

    VC-3: 1

    VC-4-3

    VC-4-4

    15-EFS4: VC4-4

    VC-12: 1-5

    15-EFS4: VC-4-1

    VC-3: 1

    Station

    Step 4: Timeslot Allocation Diagram

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    20/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 19

    Configuring the EPL Service

    Configuring the Point-to-Point EPL Service:

    Configuration Process

    Step 1: Creating a board

    Step 2: Configuring Ethernet interfaces

    Step 3: Configuring binding paths

    Step 4: Creating the point-to-point EPL service

    Step 5: Configuring committed access rate (CAR)

    (Optional )

    Step 6: Configuring the cross-connect from Ethernet

    boards to SDH line boards

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    21/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 20

    Configuring the EPL Service

    Step 1: Creating a board

    Right click

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    22/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 21

    Configuring the EPL Service Step 2: Configuring Ethernet interfaces

    Right click

    Left click

    Left click

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    23/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 22

    Configuring the EPL Service Step 3: Configuring binding paths

    Left click

    Left click

    Left click

    Left click

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    24/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 23

    Configuring the EPL Service

    Step 4: Creating the point-to-point EPL service

    Left clickLeft click

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    25/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 24

    Configuring the EPL Service

    Left click

    Step 4: Configuring committed access rate (CAR) (Optional )

    Left click

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    26/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 25

    Configuring the EPL Service

    Step 6: Configuring the cross-connect from Ethernet boards to SDH line boards

    Left click Left clickLeft click

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    27/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 26

    Summary

    Creating an Ethernet board

    Configuring Ethernet interfaces

    External Port: Basic Attributes, Tag Attribute

    Internal Port: Tag Attribute, LCAS

    Configuring binding paths: Configurable Ports, Level, Direction, Available VC4, timeslots

    Creating the MAC shared EPL service:

    Service Type, Service Direction, Ports, VLAN, TAG, Port Type

    Configuring committed access rate (CAR):

    CAR ID, Capacity, Ports

    Configuring the cross-connect from Ethernet boards to SDH line boards

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    28/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 27

    Configuring the EPL Service

    For EPL Service, there are three types:

    the Point-to-Point EPL Service

    the MAC Shared EPL Service

    the VCTRUNK Shared EPL Service

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    29/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 28

    Configuring the EPL Service

    Configuring the MAC Shared EPL Service :

    Engineering Requirements

    Engineering Planning

    Configuration Process

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    30/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 29

    STM-16two-fiberbidirectional MSP ring

    T2000

    STM-4two-fiberbidirectional non-

    protection chain

    NE1

    NE2

    NE3

    NE4

    NE5

    Engineering Requirements

    Configuring the EPL Service

    Configuring the MAC Shared EPL Service:

    Source User Service requirement Source station Sink User Sink station Bandwidth

    C MAC Shared NE1 C(1) NE5 10 Mbit/s

    C MAC Shared NE1 C(2) NE5 10 Mbit/s

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    31/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 30

    Configuring the EPL Service

    Engineering Planning

    Configuring the MAC Shared EPL Service :

    Step 1: Networking Diagram Step 2: Board Information of Each NE

    Step 3: Service Configuration Diagram of Each NE

    Step 4: Timeslot Allocation Diagram

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    32/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 31

    T2000NE1

    NE2

    NE3

    NE4 NE5A B

    A BVC-Trunk

    MAC1 MAC2

    MAC1 MAC2

    MAC3 MAC4

    C(2)C(1)

    C (Headquarters)

    MAC3

    C & C(1) Service

    C & C(2) Service

    Configuring the EPL Service

    Step 1: Networking Diagram

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    33/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 32

    VC4-4:VC12-1~VC12-5

    MAC1A

    10M

    40M

    B

    VCTRUNKMAC

    MAC2

    VCTRUNK1

    VCTRUNK2

    VC-4-1:VC-3-1SDH

    VC4-4:VC12-1~VC12-5

    VCTRUNK

    VCTRUNK1

    VCTRUNK2

    VC-4-1:VC-3-1

    MAC1A

    10M

    40MB

    MAC

    MAC2

    NE1 NE5

    VCTRUNK3

    VCTRUNK4

    MAC3C1

    10M

    10M

    C2MAC4

    VC4-4:VC12-6~VC12-10

    VC4-4:VC12-11~VC12-15

    VCTRUNK3

    VCTRUNK4

    VC4-4:VC12-6~VC12-10

    VC4-4:VC12-11~VC12-15

    MAC3C

    Configuring the EPL Service

    Step 3: Service Configuration Diagram of Each NE

    Step 2: Board Information of Each NE

    NE1 and NE5 do not require any new board.

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    34/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 33

    Configuring the EPL Service

    Step 3: Service Configuration Diagram of Each NE

    Service Attribute C & C(1) C & C(2)

    Source NE NE1

    Source board - port 13-N1EFS4-3

    Source timeslot VC4-4: VC12-6VC12-10 VC4-4: VC12-11VC12-15

    Source VCTRUNK VCTRUNK3 (Tag aware) VCTRUNK4 (Tag aware)

    Working mode of source MAC port Auto negotiation Auto negotiation

    TAG flag of source MAC port Tag aware Tag aware

    VLAN ID of source MAC port 3 4

    Bound bandwidth 5 x VC-12 5 x VC-12

    Sink NE NE5

    Sink board - port 15-N1EFS4-3 15-N1EFS4-4

    Sink timeslot VC4-4: VC12-6VC12-10 VC4-4: VC12-11VC12-15

    Sink VCTRUNK VCTRUNK3 (Tag aware) VCTRUNK4 (Tag aware)

    Working mode of sink MAC port Auto negotiation Auto negotiation

    TAG flag of sink MAC port Access Access

    VLAN ID of sink MAC port 3 4

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    35/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 34

    Timeslot

    NE2Station NE3 NE4NE1

    12-SL16-1

    NE1

    7-SL16-112-SL16-17-SL16-112-SL16-17-SL16-112-SL16-1 7-SL16-1

    Forwared

    NE5StationNE4

    13-SL4-1 7-SL4-1

    Ring

    Chain

    Add/Drop

    VC-4-3 13-EFS4: VC4-4

    VC-12: 6-15

    VC-4-315-EFS4: VC4-4

    VC-12: 6-15

    Configuring the EPL Service

    Step 4: Timeslot Allocation Diagram

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    36/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 35

    Notice: We dont need the first step because the Ethernet boards

    Have already been created.

    Configuring the EPL Service

    Configuring the MAC Shared EPL Service:

    Configuration Process

    Step 1: Creating a board (None)

    Step 2: Configuring Ethernet interfaces

    Step 3: Configuring binding paths

    Step 4: Creating the MAC shared EPL service

    Step 5: Configuring committed access rate (CAR) (Optional

    Step 6: Configuring the cross-connect from Ethernet

    boards to SDH line boards

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    37/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 36

    Configuring the EPL Service Step 2: Configuring Ethernet interfaces

    Right click

    Left click

    Left click

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    38/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 37

    Configuring the EPL Service

    Left click

    Left click

    Left click

    Left click

    Step 3: Configuring binding paths

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    39/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 38

    Left click

    Configuring the EPL Service

    Left click

    Step 4: Creating the MAC shared EPL service

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    40/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 39

    Notice: These two steps are the same as that of the

    point-to-point EPL service, except that some

    parameters are different.

    Configuring the EPL Service

    Step 5: Configuring committed access rate (CAR) (Optional

    Step 6: Configuring the cross-connect from Ethernet boards to

    SDH line boards

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    41/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 40

    Summary

    Creating an Ethernet board

    Configuring Ethernet interfaces

    External Port: Basic Attributes, Tag Attribute

    Internal Port: Tag Attribute, LCAS

    Configuring binding paths:

    Configurable Ports, Level, Direction, Available VC4, timeslots

    Creating the MAC shared EPL service:

    Service Type, Service Direction, Ports, VLAN, TAG, Port Type

    Configuring committed access rate (CAR):

    CAR ID, Capacity, Ports

    Configuring the cross-connect from Ethernet boards to SDH line boards

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    42/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 41

    For EPL Service, there are three types:

    the Point-to-Point EPL Service

    the MAC Shared EPL Service

    the VCTRUNK Shared EPL Service

    Configuring the EPL Service

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    43/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 42

    Configuring the EPL Service

    Configuring the VCTRUNK Shared EPL Service :

    Engineering Requirements

    Engineering Planning

    Configuration Process

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    44/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 43

    STM-16 two-fiberbidirectional MSP ring

    T2000

    STM-4 two-fiber

    bidirectional non- protection chainNE1

    NE2

    NE3

    NE4

    NE5

    Engineering Requirements

    Configuring the EPL Service

    Configuring the VCTRUNK Shared EPL Service:

    Source

    User

    Service

    requirement

    Source

    station

    Sink User Sink

    station

    Bandwidth

    D VCTRUNK Shared NE2 D NE3 300 Mbit/s

    E VCTRUNK Shared NE2 E NE3 300 Mbit/s

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    45/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 44

    Configuring the EPL Service

    Configuring the VCTRUNK Shared EPL Service :

    Engineering Planning

    Step 1: Networking Diagram

    Step 2: Board Information of Each NE

    Step 3: Service Configuration Diagram of Each NE

    Step 4: Timeslot Allocation Diagram

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    46/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 45

    T2000

    NE1

    NE2

    NE3

    NE4

    NE5

    D

    B

    VC-Trunk

    MAC1

    MAC2

    MAC2MAC1

    E

    D E D & D Service

    E & E Service

    Configuring the EPL Service

    Step 1: Networking Diagram

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    47/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 46

    Configuring the EPL Service

    Step 2: Board Information of Each NEBoard layout of NE2 and NE3

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    48/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 47

    MAC1D300M

    E

    VCTRUNKMAC

    MAC2

    SDH

    VC4-1:VC3-1~VC3-3

    VC4-2:VC3-1~VC3-3

    VCTRUNK

    VCTRUNK1

    MAC1 D

    E

    MAC

    MAC2

    NE2 NE3

    300M

    300M

    300MVC4-1:VC3-1~VC3-3

    VC4-2:VC3-1~VC3-3

    VCTRUNK1

    Configuring the EPL Service

    Step 3: Service Configuration Diagram of Each NE

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    49/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 48

    Configuring the EPL Service

    Step 3: Service Configuration Diagram of Each NE

    Service Attribute D E

    Source NE NE2

    Source board - port 13-N1EGS2-1 13-N1EGS2-2

    Source timeslot VC4-1: VC3-1VC3-3, VC4-2: VC3-1VC3-3

    Source VCTRUNK VCTRUNK1 (Tag aware)

    Working mode of source MAC port 1000M full duplex 1000M full duplex

    TAG flag of source MAC port Access Access

    VLAN ID of source MAC port 1 2

    Bound bandwidth 6 x VC-3

    Sink NE NE3

    Sink board - port 13-N1EGS2-1 13-N1EGS2-2

    Sink timeslot VC4-1: VC3-1VC3-3, VC4-2: VC3-1VC3-3

    Sink VCTRUNK VCTRUNK1 (Tag aware)

    Working mode of sink MAC port 1000M full duplex 1000M full duplex

    TAG flag of sink MAC port Access Access

    VLAN ID of sink MAC port 1 2

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    50/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 49

    Timeslot

    NE2Station NE3 NE4NE1

    12-SL16-1

    NE1

    7-SL16-112-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1

    Forward

    Ring

    Add/Drop

    VC-4-313-EGS2: VC4-1

    VC-3: 1-3

    VC-4-413-EGS2: VC4-2

    VC-3: 1-3

    Configuring the EPL Service

    Step 4: Timeslot Allocation Diagram

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    51/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 50

    Notice: The steps are the same as the MAC shared EPL Service.

    So here we dont need introduce them again.

    Configuring the EPL Service

    Configuring the VCTRUNK Shared EPL Service:Configuration Process

    Step 1:Creating a board

    Step 2: Configuring Ethernet interfaces

    Step 3: Configuring binding paths

    Step 4: Creating the VCTRUNK shared EPL service

    Step 5: Configuring committed access rate (CAR) (Optional )

    Step 6: Configuring the cross-connect from Ethernet boards to

    SDH line boards

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    52/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 51

    Summary

    Creating an Ethernet board

    Configuring Ethernet interfaces

    External Port: Basic Attributes, Tag Attribute

    Internal Port: Tag Attribute, LCAS

    Configuring binding paths:

    Configurable Ports, Level, Direction, Available VC4, timeslots Creating the VCTRUNK shared EPL service:

    Service Type, Service Direction, Ports, VLAN, TAG, Port Type

    Configuring committed access rate (CAR):

    CAR ID, Capacity, Ports

    Configuring the cross-connect from Ethernet boards to SDH line

    boards

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    53/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 52

    Chapter 1 The Basic Concepts

    Chapter 2 The EPL Service Configuration

    Chapter 3 The EPLAN Service Configuration

    Chapter 4 The EVPL Service Configuration

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    54/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 53

    Configuring the EPLAN Service

    Configuring the EPLAN Service:

    Engineering Requirements

    Engineering Planning

    Configuration Process

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    55/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 54

    STM-16two-fiberbidirectional MSP ring

    T2000STM-4 two-fiber

    bidirectional non- protection chainNE1

    NE2

    NE3

    NE4NE5

    Configuring the EPLAN Service

    Engineering Requirements

    Source User Service requirement Source station Sink User Sink station Bandwidth

    F(1) EPLAN NE2 F(2) NE3 10 Mbit/s

    F(3) EPLAN NE4 F(2) NE3 10 Mbit/s

    F(1) EPLAN NE2 F(3) NE4 10 Mbit/s

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    56/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 55

    Configuring the EPLAN Service

    Engineering Planning

    Step 1: Networking Diagram

    Step 2: Board Information of Each NE

    Step 3: Service Configuration Diagram of Each NE

    Step 4: Timeslot Allocation Diagram

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    57/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 56

    T2000

    NE1

    NE2

    NE3

    NE4

    NE5

    B

    VC-Trunk

    MAC1

    MAC1

    F(1)

    F(2)

    MAC1

    F(3)

    VB

    MAC1

    VCTRUNK1

    MAC1

    VCTRUNK2VCTRUNK1 VB

    VB

    MAC1

    VCTRUNK1

    F(1) & F(2) Service

    F(3) & F(2) Service

    F(1) & F(3) Service

    Configuring the EPLAN Service

    Step 1: Networking Diagram

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    58/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 57

    Board layout of NE2 and NE3

    Configuring the EPLAN Service

    Step 2: Board Information of Each NE

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    59/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 58

    Configuring the EPLAN Service

    Step 2: Board Information of Each NEBoard layout of NE4

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    60/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 59

    Service configuration diagram

    MAC1F2

    10M

    VCTRUNKMAC

    SDH

    VC4-4:VC12-1~VC12-5

    VCTRUNK

    VCTRUNK1

    MAC1F1

    MAC

    NE3

    NE2

    10M

    VC4-4:VC12-1~VC12-5VCTRUNK1

    VB1

    LP1 LP2

    LP3

    VCTRUNK2VC4-4:VC12-6~VC12-10

    VB1

    VC4-4:VC12-1~VC12-5

    VCTRUNK

    VCTRUNK1

    MAC1F3

    MAC

    NE4

    10M

    VB1

    LP1

    LP1

    LP2

    LP2

    Configuring the EPLAN Service

    Step 3: Service Configuration Diagram of Each NE

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    61/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 60

    Configuring the EPLAN Service

    Attribute \ Service F

    Source NE NE3

    Source board port 14-N1EFS0-1

    Source timeslot VC4-4: VC12-1VC12-5 VC4-4: VC12-6VC12-10

    Source VCTRUNK VCTRUNK1 (Tag Aware) VCTRUNK2 (Tag Aware)

    Source VCTRUNK attribute PE PE

    Working mode of source MAC port Auto negotiation

    TAG flag of source MAC port Access

    VLAN ID of source MAC port 11

    VB VB1

    Attached port MAC1, VCTRUNK1, VCTRUNK2

    Sink NE NE2 NE4

    Sink board port 14-N1EFS0-1 15-N1EFS0-1

    Sink timeslot VC4-4: VC12-1VC12-5 VC4-4: VC12-1VC12-5

    Sink VCTRUNK VCTRUNK1 (Tag Aware) VCTRUNK1 (Tag Aware)

    Sink VCTRUNK attribute PE PE

    Working mode of sink MAC port Auto negotiation Auto negotiation

    TAG flag of sink MAC port Access Access

    VLAN ID of sink MAC port 11 11

    Virtual bridge (VB) VB1 VB1

    Attached port MAC1, VCTRUNK1 MAC1, VCTRUNK1

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    62/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 61

    Configuring the EPLAN Service

    Step 3: Service Configuration Diagram of Each NE

    Step 4: Timeslot Allocation Diagram

    NE name VB VLAN ID Forwarding port

    NE2 VB1 11 LP1, LP2

    NE3 VB1 11 LP1, LP2, LP3

    NE4 VB1 11 LP1, LP2

    Timeslot

    NE2Station NE3 NE4NE1

    12-SL16-1

    NE1

    7-SL16-112-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1

    Forward

    Ring

    Add/Drop

    VC-4-5 14-EFS0: VC4-4

    VC-12: 1-5

    15-EFS0: VC4-4

    VC-12: 1-5

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    63/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 62

    Configuring the EPLAN Service

    Configuration Process

    Step 1: Creating a board

    Step 2: Configuring Ethernet interfaces

    Step 3: Configuring binding paths

    Step 4: Creating the EPLAN service

    Step 5: Configuring the forwarding filter table

    Step 6: Configuring committed access rate (CAR) (Optional )

    Step 7: Configuring the cross-connect from Ethernet boards to

    SDH line boards

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    64/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 63

    Configuring the EPLAN Service

    Step 1: Creating a board

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    65/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 64

    Configuring the EPLAN Service Step 2: Configuring Ethernet interfaces

    Right click

    Left click

    Left click

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    66/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 65

    Left click

    Configuring the EPLAN Service

    Left click

    Left click

    Left click

    Step 3:

    Configuring

    binding paths

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    67/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 66

    Left click

    Configuring the EPLAN Service Step 4: Creating the EPLAN service

    Left click

    Left click

    Left click

    Left click

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    68/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 67

    Configuring the EPLAN Service Step 5: Configuring the forwarding filter table

    Left click

    Left click

    Left click

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    69/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 68

    Configuring the EPLAN Service Step 6: Configuring committed access rate (CAR) (Optional )

    Left click

    Left click

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    70/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 69

    Configuring the EPLAN Service Step 7: Configuring the cross-connect from Ethernet boards to SDH line

    boards

    Left click

    Left clickLeft click

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    71/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 70

    Summary

    Creating an Ethernet board

    Configuring Ethernet interfaces

    External Port: Basic Attributes, Tag Attribute, VLAN

    Internal Port: Tag Attribute, VLAN, LCAS

    Configuring binding paths:

    Configurable Ports, Level, Direction, Available VC4, timeslots Creating the EPLAN service:

    VB Port, Mount Port, Port Type, Binding Path

    Configuring the forwarding filter table

    VB Port, VLAN ID, forwarding port

    Configuring committed access rate (CAR):

    CAR ID, Capacity, Ports

    Configuring the cross-connect from Ethernet boards to SDH line boards

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    72/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 71

    Chapter 1 The Basic Concepts

    Chapter 2 The EPL Service Configuration

    Chapter 3 The EPLAN Service Configuration

    Chapter 4 The EVPL Service Configuration

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    73/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 72

    Configuring the EVPL Service

    Configuring the EVPL Service:

    Engineering Requirements

    Engineering Planning

    Configuration Process

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    74/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 73

    STM-16 two-fiberbidirectional MSP ring

    T2000 STM-4 two-fiber

    bidirectional non-protection chainNE1

    NE2

    NE3

    NE4NE5

    Configuring the EVPL Service

    Engineering Requirements

    Source

    User

    Service

    requirement

    Source

    stationSink User

    Sink

    stationBandwidth

    D EVPL NE2 D NE3 100 Mbit/s

    E EVPL NE2 E NE3 100 Mbit/s

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    75/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 74

    Configuring the EVPL Service

    Engineering Planning

    Step 1: Networking Diagram

    Step 2: Board Information of Each NE

    Step 3: Service Configuration Diagram of Each NE

    Step 4: Timeslot Allocation Diagram

    Configuring the EVPL Service

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    76/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 75

    T2000

    NE1

    NE2

    NE3

    NE4

    NE5

    D

    B

    VC-Trunk

    MAC1

    MAC2

    MAC2MAC1

    E

    D ED & D Service

    E & E Service

    g g

    Step 1: Networking Diagram

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    77/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 76

    Configuring the EVPL Service Step 2: Board Information of Each NE

    Board layout of NE2 and NE3

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    78/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 77

    Configuring the EVPL Service

    Step 3: Service Configuration Diagram of Each NE

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    79/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 78

    Configuring the EVPL Service

    Step 3: Service Configuration Diagram of Each NE

    Attribute \ Service D ESource NE NE2

    Source board - port 14-N1EFS0-1 14-N1EFS0-2

    Source timeslot VC4-4: VC12-1VC12-48

    Source VCTRUNK VCTRUNK1 (Tag Aware )

    Source VCTRUNK attribute PWorking mode of source MAC port 100M full duplex 100M full duplex

    TAG flag of source MAC port Tag Aware Tag Aware

    VLAN ID of source MAC port 11 11

    Source MAC attribute PE PE

    Bound bandwidth 48 x VC-12

    Sink NE NE3

    Sink board - port 14-N1EFS0-1 14-N1EFS0-2

    Sink timeslot VC4-4: VC12-1VC12-48

    Sink VCTRUNK VCTRUNK1 (Tag Aware )Sink VCTRUNK attribute P

    Working mode of sink MAC port 100M full duplex 100M full duplex

    TAG flag of sink MAC port Tag Aware Tag Aware

    VLAN ID of sink MAC port 11 11

    Sink MAC attribute PE PE

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    80/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 79

    Configuring the EVPL Service

    Step 3: Service Configuration Diagram of Each NE

    Step 4: Timeslot Allocation Diagram

    NE nameVCTRUNK-MAC

    (path)

    multi-protocol label switching (MPLS)

    Tunnel VC

    NE2 \ NE3 VCTRUNK1-MAC1 55 25

    NE2 \ NE3 VCTRUNK1-MAC2 66 26

    Station

    Timeslot

    NE1 NE2 NE3 NE4 NE1

    12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1

    VC4-4

    VC12: 1-48

    14EFS0: VC4-4

    Forward

    Add/Drop

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    81/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 80

    Configuring the EVPL Service

    Configuration Process

    Step 1: Creating a board

    Step 2: Configuring Ethernet interfaces

    Step 3: Configuring binding paths

    Step 4: Creating the EVPL service

    Step 5: Configuring committed access rate (CAR)

    (Optional )

    Step 6: Configuring the cross-connect from Ethernet

    boards to SDH line boards

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    82/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 81

    Configuring the EVPL Service

    Step 1: Creating a board

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    83/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 82

    Configuring the EVPL Service Step 2: Configuring Ethernet interfaces

    Right click

    Left click

    Left click

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    84/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 83

    Configuring the EVPL Service Step 3: Configuring binding paths

    Left click

    Left click

    Left click

    Left click

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    85/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 84

    Configuring the EVPL Service

    Step 4: Creating the

    EVPL service

    Left clickLeft click Left click

    Configuring the EVPL Service

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    86/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 85

    Notice: These two steps are the same as that of the EPL service,

    except that some parameters are different.

    Configuring the EVPL Service

    Step 5: Configuring committed access rate (CAR)

    (Optional )

    Step 6: Configuring the cross-connect from Ethernet

    boards to SDH line boards

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    87/88

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 86

    Summary

    Creating an Ethernet board

    Configuring Ethernet interfaces

    External Port: Basic Attributes, Tag Attribute, VLAN

    Internal Port: Tag Attribute, VLAN, LCAS, MPLS

    Configuring binding paths:

    Configurable Ports, Level, Direction, Available VC4, timeslots

    Creating the EVPL service:

    Service Type, Service Direction, Ports, TAG, VLAN, Tunnel, VC,

    Port Type, Encapsulation Format

    Configuring committed access rate (CAR):

    CAR ID, Capacity, Ports

    Configuring the cross-connect from Ethernet boards to SDH line

    boards

  • 7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21

    88/88

    www.huawei.com

    Thank You