19-26 Sanders Lodge Site plan

Page 2: 19-26 Sanders Lodge Site plan - Northamptonshire

4803 4812 4812 6146 4812 4812 480335000 approx

6000

10 degree roof pitch

9150

app

rox

to e

aves

764605700 6000 6000 6000 6000 5172 5812 5812 5812 5812 5812 5812 5816 600300

roller shutter door

0 1m 2m 3m 4m 5m 6m 7m 8m 9m 10m

SCALE BAR

roller shutter door

roller shutter door

roller shutter door

roller shutter door

GABLE ELEVATION - ARROW A.

GABLE ELEVATION - ARROW B.

SIDE ELEVATION - ARROW C.

SIDE ELEVATION - ARROW D.

existing building

existing building

outline of existing building

outline of existing building

exis

ting

build

ing

exis

ting

build

ing

exis

ting

build

ing

6000

8000

step

in fl

oor l

evel 7500

5500

roller shutter door55

00

5500

9950

app

rox

to ri

dge

6 degree roof pitch

roof clad in Plastisol coated steel sheets 0.7 thickcolour to suit Local Authority

roof clad in Plastisol coated steel sheets 0.7 thickcolour to suit Local Authority

vertical clad in Pastisol coated 'ventair' sheetswith insect proof mesh to inside orstandard Plasticol coated sheet shtsColour to suit Local Authority

existing building

6000

8000

roof clad in Plastisol coated steel sheets 0.7 thickcolour to suit Local Authority

vertical clad in Plasticol coated sheet shtsColour to suit Local Authority

Plastisol coated roller shutter doors

step in roof, with valley gutter,and Plastisol coated sheets

open between old and new buildingsopen between old and new buildings

galv. valley gutter

PVC gutter

Shobdon Airfield, Shobdon, Nr Leominster, Herefordshire. HR6 9NR

Tel: 01568 708456 / 708114 Fax: 01568708212Email: [email protected]

Client

Job Title

Site

Drawing Title

DrawnDateScale

DRAWING No.REVISION

Revision By Date

Building to BS EN 1090 EXC 2

Monoworld Recycling LtdSanders Lodge Ind EstRushdenNorthantsNN10 6BQ

DGMNovember 2016

1:150 / not to scale at A1

ELEVATIONS OF PROPOSAL

26598 / 2

Page 3: 19-26 Sanders Lodge Site plan - Northamptonshire

EXISTING SUPERCRAFT BUILDING10000 approx to eaves

EXISTING JRC BUILDING6000 approx to eaves

EXISTING BUILDING7500 approx to eaves

EXISTING BUILDING7000 approx to eaves

edge of existing concrete yard

89500 approx

porta

l fra

me

3500

0 / 3

3000

spa

n

ridge line

ridge

line

this side clad to floor level

roller shutter door6000 wide x 5500 high

roller shutter door7500 wide x 5500 highthis side clad to floor level except around existing buildings

35100 outside existing columns

533 x 210 x '101' UB columns

533 x 210 x '101' UB columns

BUILDING A.

BUILDING B.

BUILDING A.

76460 long (13 bays) x 35000 / 33000 span free standing portal frame building10 degree roof pitch

this building to be 6000 to eaves, to allow for 5500 high roller shutter doors

BUILDING B.

10375 appprox x 35000 approx span x 8000 to eaves10 degree roof pitch

1037

5 a

ppro

x

NOTE!All dimensions are based on approximate initial site dimensions.Therefore they are for guideline extimating purposes only, and not to be scaled etc.

All steel sizes are subject to strucrural calculations.

GENERAL NOTES.

ROOF CLADDING single skin Plastisol coated steel sheets 0.7 thick

VERTICAL CLADDINGsingle skin Plastisol coated steel sheets 0.5 thick VENTAIRwith fine plastic mesh liner (to help prevent insect movement)

Mesh to have holes of 1.5mm or 2mm square.Based on roll width of 1200mm, rails to be spaced at 1100mm centres to allow lapping of

mets between rails and cladding sheet.

JUNCTIONS TO EXISTING BUILDINGSGable cladding to be flashed into existing JRC buildings gutter.

All other buidling are higher than the proposal. Sealed flashing to be fitted between new building and existing vertical sheets.

valley gutter between existing and new buildings,with sealed flashing to existing vertical cladding

flashing down into existing gutter

457 x 191 x '74' UB rafters

457 x 191 x '74' UB rafters

610 x 229 x '140' UB column

carrier beam to take rafters686 x 254 x '152' UB

(valley gutter also along this line)

457 x 191 x '74' UB rafter

step in roof, with Buiding B being higherby approximately 2000mm

533

x 21

0 x

82 U

B c

arrie

r bea

m

457

x 19

1 x

'74'

UB

rafte

rs

here the new building isapproximately 2000 HIGHER than the existing building

here the new building is approximately 1800mm LOWER than the existing building

cladding down between roofs

76460

roller shutter door6000 wide x 5500 high

2000

0 a

ppro

x

457

x 19

1 x

'74'

UB

rafte

rs

457

x 19

1 x

'74'

UB

rafte

rs

457

x 19

1 x

'74'

UB

rafte

rs

457

x 19

1 x

'74'

UB

rafte

rs

457

x 19

1 x

'74'

UB

rafte

rs

457

x 19

1 x

'74'

UB

rafte

rs

457

x 19

1 x

'74'

UB

rafte

rs

457

x 19

1 x

'74'

UB

rafte

rs

457

x 19

1 x

'74'

UB

rafte

rs

457

x 19

1 x

'74'

UB

rafte

rs

457

x 19

1 x

'74'

UB

rafte

rs

457

x 19

1 x

'74'

UB

rafte

rs

457

x 19

1 x

'74'

UB

rafte

rs

5700 6000 6000 6000 6000 5172 5812 5812 5812 5812 5812 5812 5816

all bay centres approximate

existing 406 x 178 UB columns

4 columns circles are to be stubbed off existing columns,(subject to structural engineers approval)

600300

0 1m 2m 3m 4m 5m 6m 7m 8m 9m 10m

SCALE BAR

A

B

C

D

roller shutter door

roller shutter door roller shutter door roller shutter door

Shobdon Airfield, Shobdon, Nr Leominster, Herefordshire. HR6 9NR

Tel: 01568 708456 / 708114 Fax: 01568708212Email: [email protected]

Client

Job Title

Site

Drawing Title

DrawnDateScale

DRAWING No.REVISION

Revision By Date

Building to BS EN 1090 EXC 2

Monoworld Recycling LtdSanders Lodge Ind EstRushdenNorthantsNN10 6BQ

DGMSeptember 2016

1:200 / not to scale at A1

LAYOUT OF PROPOSAL

26598 / 1 E

A dgm 26.9.16 building dimensions altered

B dgm 28.9.16 building dimensions altered

D dgm 8.11.16 written dimensions revised

E dgm 11.11.16 doors moved / elev arrows added

Page 4: 19-26 Sanders Lodge Site plan - Northamptonshire