1
Rx Rx Tx Tx Module 1 Redundant Network Module 2 Redundant Network IRIS Fire Alarm Panel Rx Rx Rx Rx Tx Tx Tx Tx + Tx + Rx + Rx - Tx - Tx - Rx - Rx + Tx 18020194 Repeater Panel - Instruction Manual Technical Characteristics: Power Supply: (24 ± 4) VDC Max. consumption: 0.11A Communication - RS485 Twisted pair cable: - Length - max. 1000m (between repeater - fire panel) 2 - Cross Section - 0.5 - 2.5mm 2. Connection Diagram ATTENTION! Operation with Repeater Panel is supported for the following revisions: IRIS Fire Alarm Panel LCD PCB Hardware revision: 2.4 and higher MAIN Board Firmware revision: 4.2 and higher SIMPO Fire Alarm Panel MAIN Board Firmware revision: 2.8 and higher 1. Description of the terminal rows 24 VDC Loop IN Loop OUT Power Supply Loop IN - Connect the input line for communication Loop OUT - Connect the output line for communication Power Supply - Power supply for the repeater panel: - Use external 24VDC power supply unit; - Use the AUX output of the fire alarm panel. Micro USB - Micro USB input for programming and firmware update SIMPO Fire Alarm Panel Micro USB Repeater Panel Rx Rx Tx Tx

18020194-Connection Instruction Repeater panel 092014...IRIS Fire Alarm Panel Rx Rx Rx Rx Tx Tx Tx Tx + Tx + Rx + Rx - Tx - Tx - Rx - Rx + Tx 18020194 Repeater Panel - Instruction

  • Upload
    others

  • View
    28

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 18020194-Connection Instruction Repeater panel 092014...IRIS Fire Alarm Panel Rx Rx Rx Rx Tx Tx Tx Tx + Tx + Rx + Rx - Tx - Tx - Rx - Rx + Tx 18020194 Repeater Panel - Instruction

Rx RxTx Tx

Module 1Redundant Network

Module 2Redundant Network

IRIS Fire Alarm Panel

Rx

Rx

Rx

Rx

Tx TxTx Tx

+ Tx

+ Rx+ Rx

- Tx

- Tx

- Rx

- Rx

+ Tx

18

02

01

94

Repeater Panel - Instruction Manual

Technical Characteristics:Power Supply: (24 ± 4) VDCMax. consumption: 0.11ACommunication - RS485

Twisted pair cable:- Length - max. 1000m (between repeater - fire panel)

2- Cross Section - 0.5 - 2.5mm

2. Connection Diagram

ATTENTION!Operation with Repeater Panelis supported for the following revisions:

IRIS Fire Alarm PanelLCD PCB Hardware revision: 2.4 and higherMAIN Board Firmware revision: 4.2 and higher

SIMPO Fire Alarm PanelMAIN Board Firmware revision: 2.8 and higher

1. Description of the terminal rows

24 VDC

Loop IN Loop OUT Power Supply

Loop IN - Connect the input line for communicationLoop OUT - Connect the output line for communicationPower Supply - Power supply for the repeater panel: - Use external 24VDC power supply unit; - Use the AUX output of the fire alarm panel.Micro USB - Micro USB input for programming and firmware update