Upload
ngodat
View
356
Download
9
Embed Size (px)
Citation preview
155 mm ammunition155 mm HE extended range ammunition is designed to be fired from 155 mm self-propelled howitzers (Krab, Zuzana).
Zakłady Metalowe DEZAMET S.A., 1 Szypowskiego St, 39-460 Nowa Dęba, Poland, www.dezamet.com.pl, District Court in Rzeszów, XII Commercial Division, Register No. 0000044261, shares capital 19.241.750,00 PLN, NIP 867-000-30-16, PN-EN ISO 9001, PN-EN ISO 14001, PN-N 18001, NCAGE 0234H.
Zakłady Metalowe DEZAMET S.A., 1 Szypowskiego St, 39-460 Nowa Dęba, Poland, www.dezamet.com.pl, District Court in Rzeszów, XII Commercial Division, Register No. 0000044261, shares capital 19.241.750,00 PLN, NIP 867-000-30-16, PN-EN ISO 9001, PN-EN ISO 14001, PN-N 18001, NCAGE 0234H.
The ammunition meets standard requirements as specifi ed in JB MoU agreement. The round is armed with a KZ-984 dual purpose impact fuse (immediate action or short-delay action). The fuse meets all safety standards requirements established by NATO (STANAG 4187). Minimal arming distance – 80 m. Ammunition is fi lled with TNT or Comp B TNT/RDX. Operating time of the round is 25 years. Apart from a projectile the round also consists of self-igniting modular charges (without shell-cases).
Technical data:
Round weight (kg)
Length with fuse (mm)
Length without fuse (mm)
Fuse
Explosive material (RDX/TNT) (kg)
Muzzle velocity V0 (m/s)
Max. eff ective range (m)
Propellant charge
Number of propelant charges (qty)
Operation temperature range (°C)
Round weight (kg)
Length with fuse (mm)
Length without fuse (mm)
Fuse
Explosive material (RDX/TNT) (kg)
Muzzle velocity V0Muzzle velocity V0Muzzle velocity V (m/s)
Max. eff ective range (m)
Propellant charge
Number of propelant charges (qty)
Operation temperature range (°C)
Extended rangeHE round44
44
917,3
831,7
impact KZ-984
8,2
945
31 000
Bi – modular artillery charge system(CHARGE XE, XF)
max. 6
- 40 ÷ +50
Extended range HE round with gas generator 47
47
926,3
840,7
impact KZ-984
8,2
942
41 200
Bi – modular artillery charge system(CHARGE XE, XF)
4 ÷ 6
- 40 ÷ +50