128
AIR CONDITIONERS 14ACX MERIT ® Series R-410A Bulletin No. 210740 November 2017 Supersedes August 2017 SEER up to 16.00 1.5 to 5 Tons Cooling Capacity - 17,900 to 59,000 Btuh 14 AC x – 024 - 230 A 02 Nominal SEER Unit Type AC = Air Conditioner Refrigerant X = R-410A Nominal Cooling Capacity 018 = 1.5 tons 024 = 2 tons 030 = 2.5 tons 036 = 3 tons 041 = 3.5 tons 042 = 3.5 tons 047 = 4 tons 048 = 4 tons 059 = 5 tons 060 = 5 tons Minor Revision Level Voltage 230 = 208/230V-1phase-60hz MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS Ratings Revision Level (NOTE - 018-024-030-036-042 models only) Regional Standards – (dash) = All Regions or Southwest Region (dependent on size) S = North and South Regions

14ACX 1.5-5 TON AIR CONDITIONERS AIR CONDITIONERS 14ACX · 2019-11-09 · AIR CONDITIONERS 14ACX MERIT® Series R-410A Bulletin No. 210740 November 2017 Supersedes August 2017 SEER

  • Upload
    others

  • View
    22

  • Download
    0

Embed Size (px)

Citation preview

A I R C O N D I T I O N E R S

14ACXMERIT® Series

R-410A Bulletin No. 210740

November 2017 Supersedes August 2017

SEER up to 16.001.5 to 5 Tons

Cooling Capacity - 17,900 to 59,000 Btuh

14 AC x – 024 - 230 A 02

Nominal SEER

Unit Type AC = Air Conditioner

Refrigerant X = R-410A

Nominal Cooling Capacity 018 = 1.5 tons 024 = 2 tons 030 = 2.5 tons 036 = 3 tons 041 = 3.5 tons 042 = 3.5 tons 047 = 4 tons 048 = 4 tons 059 = 5 tons 060 = 5 tons

Minor Revision Level

Voltage 230 = 208/230V-1phase-60hz

MODEL NUMBER IDENTIFICATION

P R O D U C T S P E C I F I C AT I O N S

Ratings Revision Level (NOTE - 018-024-030-036-042 models only)

Regional Standards– (dash) = All Regions or Southwest Region (dependent on size)

S = North and South Regions

14ACX 1.5-5 TON AIR CONDITIONERS

14ACX - 1.5 to 5 Ton Air Conditioner / Page 2

WARRANTY

Compressor - limited warranty for five years in residential installations and five years in non-residential installations.

All other covered components - five years in residential installations and one year in non-residential installations.

Note - Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details.

APPROVALSAHRI Certified to AHRI Standard 210/240-2008.Sound rated in Lennox reverberant sound test room in Accordance with test conditions included in AHRI Standard 270-2008.Tested in the Lennox Research Laboratory environmental test room.Rated According to U.S. Department of Energy (DOE) test procedures.Region specific models meet the minimum efficiency requirements for U.S DOE Federal Regional Standards in that area.Units and components within bonded for grounding to meet safety standards for servicing required by UL, NEC and CEC.Units are ETL certified for the U.S. and Canada.ISO 9001 Registered Manufacturing Quality System.For expanded ratings, see www.LennoxPROs.com.

APPLICATIONSSEER up to 16.00.1.5 through 5 ton.Single-phase power supply.Sound levels as low as 76 dB.Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof.Matching add-on furnace indoor coils or air handlers provide a wide range of cooling capacities and applications. See AHRI System Matches.See Indoor Coils and Air Handlers sections for data.Units shipped completely factory assembled, piped and wired. Each unit test operated at the factory ensuring proper operation.Installer must set air conditioner, connect refrigerant lines and make electrical connections to complete job.

REFRIGERATION SYSTEM

R-410A RefrigerantNon-chlorine, ozone friendly, R-410A.Unit pre-charged with refrigerant.See Specification table.

Outdoor Coil FanDirect drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity.Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs.Fan motor has sleeve bearings (-018 through -048 and -060 models), ball bearings (-059 model) and is inherently protected.Motor totally enclosed for maximum protection from weather, dust and corrosion.Rain shield on motor provides additional protection from moisture.Louvered steel top fan guard furnished as standard.Fan service access accomplished by removal of top panel.Copper Tube/Enhanced Fin CoilLennox designed and fabricated coil.Ripple-edged aluminum fins.Copper tube construction.Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer.Fin collars grip tubing for maximum contact area.Flared shoulder tubing connections/silver soldering construction.Coil is factory tested under high pressure to ensure leakproof construction.Steel louvered panels provide complete coil protection.Panels can be completely removed for servicing.

High Capacity Liquid Line DrierFurnished with unit for field installation.Approved for use with R-410A systems.Traps any moisture or dirt that could contaminate the refrigerant system.

High Pressure SwitchShuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting.Protects compressor from excessive condensing pressure.Manual reset.

A

B

C

B

C

D

E

F

FEATURES

CONTENTSAHRI System Matches - All Regions ......................... 10AHRI System Matches - North / South Region .......... 37AHRI System Matches - Southwest Region .............. 84Dimensions - Unit ........................................................ 8Electrical Data.............................................................. 6Features....................................................................... 2Field Wiring .................................................................. 5Installation Clearances ................................................ 5Model Number Identification ........................................ 1Optional Accessories ................................................... 6Sound Data .................................................................. 9Specifications............................................................... 6TXV Usage .................................................................. 9

14ACX - 1.5 to 5 Ton Air Conditioner / Page 3

REFRIGERATION SYSTEM

R-410A RefrigerantNon-chlorine, ozone friendly, R-410A.Unit pre-charged with refrigerant.See Specification table.

Outdoor Coil FanDirect drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity.Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs.Fan motor has sleeve bearings (-018 through -048 and -060 models), ball bearings (-059 model) and is inherently protected.Motor totally enclosed for maximum protection from weather, dust and corrosion.Rain shield on motor provides additional protection from moisture.Louvered steel top fan guard furnished as standard.Fan service access accomplished by removal of top panel.Copper Tube/Enhanced Fin CoilLennox designed and fabricated coil.Ripple-edged aluminum fins.Copper tube construction.Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer.Fin collars grip tubing for maximum contact area.Flared shoulder tubing connections/silver soldering construction.Coil is factory tested under high pressure to ensure leakproof construction.Steel louvered panels provide complete coil protection.Panels can be completely removed for servicing.

High Capacity Liquid Line DrierFurnished with unit for field installation.Approved for use with R-410A systems.Traps any moisture or dirt that could contaminate the refrigerant system.

High Pressure SwitchShuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting.Protects compressor from excessive condensing pressure.Manual reset.

A

B

C

Refrigerant Flow ControlUnits applicable to expansion valve systems or RFC systems when matched with specific indoor coils.

RFCIV:Accurately meters refrigerant in system.Refrigerant control is accomplished by exact sizing of refrigerant metering orifice.The principle involves matching indoor coil with proper bore size of orifice in metering device.Equalizes pressure shortly after compressor stops, unit starts unloaded, eliminating need for additional controls.

Optional Accessories

Expansion Valve KitsMust be ordered extra and field installed on certain indoor units. See TXV Usage Table on Page 9.Chatleff-style fittings.

FreezestatInstalls on or near the vapor line of the indoor coil or on the suction line.Senses suction line temperature and cycles the compressor off when suction line temperature falls below it’s setpoint.Opens at 29°F and closes at 58°F.

Loss of Charge Switch KitHelps protect the compressor from damage due low refrigerant charge conditions.SPST, normally-closed switch, automatic reset switch mounted on liquid line.

Refrigerant Line KitsRefrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized and sealed at factory.Suction line fully insulated.Lines are stubbed at both ends.Not available for -059-060 models. Must be field fabricated.

O−RING

RFCIV METERING SYSTEMRFCIV

ORIFICE

ORIFICE BODY(On Coil)

SEALNUT SWEAT

CONNECTION

LIQUIDLINE

LIQUIDLINE SCREEN

FEATURES

14ACX - 1.5 to 5 Ton Air Conditioner / Page 4

COMPRESSORScroll CompressorCompressor features high efficiency with uniform suction flow, constant discharge flow, high volumetric efficiency and quiet operation.Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them.During compression, one scroll remains stationary while the other scroll orbits around it.Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates.As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced.When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls.During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle.Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency.Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to to be worked toward the center and discharged.Low gas pulses during compression reduces operational sound levels.Compressor motor is internally protected from excessive current and temperature.Compressor is installed in the unit on resilient rubber mounts for vibration free operation.

Compressor Crankcase Heater (-041, -047, -048, -059 & -060 Models)Protects against refrigerant migration that can occur during low ambient operation.

Optional Accessories

Compressor Crankcase Heater (Optional for 018-024-030-036-042)Protects against refrigerant migration that can occur during low ambient operation.

Compressor Sound CoverA reinforced vinyl compressor cover containing a 1-1/2 inch thick batt of fiberglass insulation.All open edges are sealed with a one-inch wide hook and loop fastening tape.

D

CONTROLS

Optional Accessories

Compressor Hard Start KitSingle-phase units are equipped with a PSC compressor motor. This type of motor normally doesn’t need a potential relay and start capacitor.In conditions such as low voltage, this kit may be required to increase the compressor starting torque.

Compressor Low Ambient Cut-Off SwitchNon-adjustable switch (low ambient cut-out) prevents compressor operation when outdoor temperature is below 35°F.

Compressor Time-Off ControlKit prevents compressor short-cycling and allows time for suction and discharge pressure to equalize.Permits compressor start-up in an unloaded condition.Automatic reset with 5 minute delay between compressor shut-off and start-up.

Indoor Blower Off Delay RelayDelays the indoor blower-off time during the cooling cycle.See AHRI System Matches for usage.

Low Ambient KitAir conditioners operate satisfactorily in the cooling mode down to 45°F outdoor air temperature without any additional controls.Kit can be added in the field enabling unit to operate properly down to 30°F in the cooling mode.Crankcase heater and freezestat should be installed on compressors equipped with a Low Ambient Kit.A compressor lock-out thermostat should be added to terminate compressor operation below recommended operation conditions.

ThermostatThermostat not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book.

FEATURES

14ACX - 1.5 to 5 Ton Air Conditioner / Page 5

CABINETHeavy gauge steel cabinet with five station metal wash process.Louvered heavy gauge steel panels surround unit on all four sides to prevent damage to the coil.Powder paint finish provides superior rust and corrosion protection.Control box is conveniently located with all controls factory wired.Corner patch plate allows access to compressor components.Drainage holes are provided in base section for moisture removal.

PermaGuard™ Unit BaseDurable zinc-coated base section resists rust and corrosion.

Refrigerant Line Connections, Electrical Inlets, Service ValvesSweat connection suction and liquid lines are located on corner of unit cabinet.Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Suction valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system.Refrigerant line connections and field wiring inlets are located in one central area of cabinet for easy access. See dimension drawing.

E

F

B

DISCONNECTSWITCH

(By Others)

LENNOXAIR

CONDITIONER

LENNOXHEATING UNIT

ORAIR HANDLER

UNIT

DISCONNECTSWITCH

(By Others)THERMOSTAT

(Optional)

C

DA

SeeNOTES

See NOTES

See NOTES

SeeNOTES

CONTROLBOX

A - Two Wire PowerB - Two Wire Power (See Electrical Data)C - Two Wire Low Voltage (18 ga. minimum)D - Four Wire Low Voltage (Electro-Mechanical) 18 ga. minimum.

Five Wire Low Voltage (Electronic) 18 ga. minimum

NOTE - Field Wiring Not FurnishedAll wiring must conform to NEC or CEC and local electrical codes.

NOTES:Service clearance of 30 in. (762 mm) must be maintained on

one of the sides adjacent to the control box.Clearance to one of the other three sides must be

36 in. (914 mm)Clearance to one of the remaining two sides may be

12 in. (305 mm) and the final side may be 6 in. (152 mm).A clearance of 24 in. must be maintained between two units.48 in. (1219 mm) clearance required on top of unit.

Optional Accessories

Unit Stand-Off KitBlack high density polyethylene feet are available to raise unit off of mounting surface away from damaging moisture.Four feet are furnished per order number.

FEATURES

FIELD WIRING INSTALLATION CLEARANCES - IN. (MM)

14ACX - 1.5 to 5 Ton Air Conditioner / Page 6

SPECIFICATIONSGeneral Data

Model No. All Regions - - - - - - - - - - - - 14ACX-041North / South Regions 14ACXS018 14ACXS024 14ACXS030 14ACXS036 - - -

Southwest Region 14ACX-018 14ACX-024 14ACX-030 14ACX-036 - - -Nominal Tonnage 1.5 2 2.5 3 3.5

Connections (sweat)

Liquid line o.d. - in. 3/8 3/8 3/8 3/8 3/8 Suction line o.d. - in. 3/4 3/4 3/4 7/8 7/8

1 Refrigerant (R-410A) furnished 4 lbs. 13 oz. 5 lbs. 9 oz. 6 lbs. 11 oz. 6 lbs. 11 oz. 10 lbs. 1 oz.Outdoor Coil

Net face area sq. ft.

Outer coil 13.22 16 21 21 21Inner coil - - - - - - - - - - - - 20.25

Tube diameter - in. 5/16 5/16 5/16 5/16 5/16Number of rows 1 1 1 1 2

Fins per inch 26 26 26 26 22Outdoor Fan

Diameter - in. 18 22 22 22 22Number of blades 3 3 3 3 4

Motor hp 1/10 1/6 1/6 1/6 1/4 Cfm 2290 3160 3160 3160 3600

Rpm 1075 825 825 825 825Watts 160 215 215 215 310

Shipping Data - lbs. 1 package 138 158 171 177 209ELECTRICAL DATA

Line voltage data - 60 hz - 1ph 208/230V 208/230V 208/230V 208/230V 208/230V2 Maximum overcurrent protection (amps) 20 25 25 30 35

3 Minimum circuit ampacity 12.4 15.0 17.1 18.6 22.6Compressor Rated load amps 9.4 11.2 12.9 14.1 16.7

Locked rotor amps 56.6 60.8 64 77 79Power factor 0.96 0.97 0.98 0.98 0.97

Condenser Fan Motor

Full load amps 0.7 1.0 1.0 1.0 1.7Locked rotor amps 1.3 1.9 1.9 1.9 3.2

OPTIONAL ACCESSORIES - ORDER SEPARATELYCompressor Crankcase Heater 93M04 • • • •

Factory •Compressor Hard Start Kit

Copeland 10J42 • • • • •LG 88M91 • •

Compressor Low Ambient Cut-Off Switch 45F08 • • • • •Compressor Sound Cover 27W55 • • • •

27W56 •Compressor Time-Off Control 47J27 • • • • •Freezestat 3/8 in. tubing 93G35 • • • • •

5/8 in. tubing 50A93 • • • • •Indoor Blower Off Delay Relay 58M81 • • • • •Loss of Charge Switch Kit 84M23 • • • • •4 Low Ambient Kit (Fan Cycling) 34M72 • • • • •Refrigerant Line Sets

L15-41-20, L15-41-30, L15-41-40, L15-41-50

• • •

L15-65-30, L15-65-40, L15-65-50

• •

Unit Stand-Off Kit 94J45 • • • • •NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.1 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and

additional refrigerant charge required.2 HACR type circuit breaker or fuse.3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 7

SPECIFICATIONSGeneral Data

Model No. All Regions - - - 14ACX-047 14ACX-048 14ACX-059 14ACX-060North / South Regions 14ACXS042 - - - - - - - - - - - -

Southwest Region 14ACX-042 - - - - - - - - - - - -Nominal Tonnage 3.5 4 4 5 5

Connections (sweat)

Liquid line o.d. - in. 3/8 3/8 3/8 3/8 3/8Suction line o.d. - in. 7/8 7/8 7/8 1-1/8 1-1/8

1 Refrigerant (R-410A) furnished 8 lbs. 10 oz. 11 lbs. 3 oz. 10 lbs. 8 oz. 11 lbs. 2 oz. 12 lbs. 0 oz.Outdoor Coil

Net face area sq. ft.

Outer coil 18.67 22 21 24.94 22Inner coil 17.96 21.33 20.25 24.14 21.33

Tube diameter - in. 5/16 5/16 5/16 5/16 5/16Number of rows 2 2 2 2 2

Fins per inch 22 22 22 22 22Outdoor Fan

Diameter - in. 22 26 22 26 26Number of blades 4 4 4 4 4

Motor hp 1/4 1/3 1/4 1/3 1/3Cfm 3500 4400 3600 4400 4400

Rpm 825 825 825 825 825Watts 310 310 310 310 310

Shipping Data - lbs. 1 package 208 250 228 266 253

ELECTRICAL DATALine voltage data - 60 hz - 1ph 208/230V 208/230V 208/230V 208/230V 208/230V

2 Maximum overcurrent protection (amps) 40 45 45 50 603 Minimum circuit ampacity 24.1 26.7 26.7 34.1 34.8

Compressor Rated load amps 17.9 19.9 20 25 26.4Locked rotor amps 112 109 99 134 134

Power factor 0.94 0.97 0.99 0.98 0.98Condenser Fan Motor

Full load amps 1.7 1.8 1.7 2.8 1.8Locked rotor amps 3.2 2.9 3.2 - - - 2.9

OPTIONAL ACCESSORIES - ORDER SEPARATELYCompressor Crankcase Heater 93M04 •

Factory • • • •Compressor Hard Start Kit

Copeland 10J42 • • • •LG 88M91 • • •

Compressor Low Ambient Cut-Off Switch 45F08 • • • • •Compressor Sound Cover 27W56 • • • • •Compressor Time-Off Control 47J27 • • • • •Freezestat 3/8 in. tubing 93G35 • • • • •

5/8 in. tubing 50A93 • • • • •Indoor Blower Off Delay Relay 58M81 • • • • •Loss of Charge Switch Kit 84M23 • • • • •4 Low Ambient Kit (Fan Cycling) 34M72 • • • •

68M04 •Refrigerant Line Sets

L15-65-30, L15-65-40, L15-65-50

• • •

Field Fabricate • •Unit Stand-Off Kit 94J45 • • • • •NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.1 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and

additional refrigerant charge required.2 HACR type circuit breaker or fuse.3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 8

SUCTION AND

C

SIDE VIEW

DISCHARGE AIR

SIDE VIEW

A

B

A

LIQUID LINECONNECTION

OUTDOORCOIL FAN

COMPRESSOR

OPTIONAL UNITSTANDOFF KIT (4)(FIELD INSTALLED)

4-3/8

INLET

AIR

INLET

AIR

TOP VIEW

INLET AIR

INLET AIR

SUCTION LINECONNECTION

LIQUID LINECONNECTION 6-3/8

(162)

TOP VIEW BASE SECTION

COMPRESSOR

COIL DRAIN OUTLETS(Around perimeter of base)

OPTIONAL UNITSTAND-OFF KIT (4)

(Field Installed)

(111)

4-3/84-3/8

4-3/8 4-3/8

6-3/8(162)

(111) (111)

(111) (111)

4-3/8(111)

2 (51)

3/4 (19)

2-3/4 (70)

ELECTRICALINLETS

ModelA B C

inches mm inches mm inches mm018 24-1/4 616 29-1/4 743 28-1/2 724024 28-1/4 718 29-1/4 743 28-1/2 724030 28-1/4 718 37-1/4 946 36-1/2 927036 28-1/4 718 37-1/4 946 36-1/2 927041 28-1/4 718 37-1/4 946 36-1/2 927042 28-1/4 718 33-1/4 845 32-1/2 826047 32-1/4 817 33-1/4 845 32-1/2 826048 28-1/4 718 37-1/4 946 36-1/2 927059 32-1/4 817 37-1/4 946 36-1/2 927060 32-1/4 817 33-1/4 845 32-1/2 826

DIMENSIONS - UNIT - INCHES (MM)

14ACX - 1.5 to 5 Ton Air Conditioner / Page 9

SOUND DATA

1 Unit Model

Octave Band Linear Sound Power Levels dB, re 10-12 Watts Center Frequency - HZ

1 Sound Rating Number (dB)

125 250 500 1000 2000 4000 8000018 69.5 70.5 71.0 71.0 69.0 63.5 57.5 76024 69.5 72.0 70.5 70.5 67.5 62.5 57.5 76030 72.5 74.0 74.0 72.0 67.5 61.5 56.5 76036 73.5 75.0 74.0 72.5 67.5 62.5 56.5 76041 76.5 74.0 73.5 73.5 70.0 62.5 58.5 78042 73.5 75.5 74.5 73.5 70.5 64.0 58.5 78047 76.5 77.5 77.5 73.5 69.0 63.5 60.5 80048 76.5 74.0 73.5 73.5 70.0 62.5 58.5 78059 79.5 76.5 76.5 72.5 68.0 63.0 60.5 78060 76.5 77.5 77.5 73.5 69.0 63.5 60.5 80NOTE - the octave sound power data does not include tonal correction.1 Tested according to AHRI Standard 270-2008 test conditions.

AHRI STANDARD 210/240

Cooling or heating capacities are net values, including the effects of blower motor heat, and do not include supplementary heat. Power input is the total power input to the compressor(s) and fan(s), plus any controls and other items required as part of the system for normal operation.Units which do not have an indoor air-circulating blower furnished as part of the model, i.e., split system with indoor coil only, is established by subtracting from the total cooling capacity 1250 Btu/h per 1,000 cfm, and by adding the same amount to the heating capacity. Total power input for both heating and cooling is increased by 365 W per 1,000 cfm of indoor air circulated.

TXV USAGEUse this table for C33, C35, CH23, CH33, CH35 and CR33 Field Installed TXV Match-Ups.Outdoor Unit Model No.

Thermal Expansion Valve (TXV)

14ACX(-)(S)018 12J1814ACX(-)(S)024 12J1814ACX(-)(S)030 12J1814ACX(-)(S)036 12J1914ACX-041 12J2014ACX(-)(S)042 12J2014ACX-047 12J2014ACX-048 12J2014ACX-059 12J2014ACX-060 12J20CX34 and CX35 upflow coils and all Lennox air handlers are shipped with a factory installed TXV. In most cases, no change out of the valve is needed.If a change out is required it will be listed in the “TXV SUBSTITUTIONS” table. The correct TXV must be ordered separately and field installed.C33, C35 and CH33 and CH35 coils - Replace the factory installed orifice with the expansion valve listed .CR33 and CH23 coils - Use the expansion valve listed.

MOST POPULAR MATCHESOutdoor Unit Model No.

Indoor Unit Model No

14ACX(-)(S)018 CX34-2514ACX(-)(S)024 CX34-2514ACX(-)(S)030 CX34-3114ACX(-)(S)036 CX34-3814ACX-041 CX34-4914ACX(-)(S)042 CX34-4914ACX-047 CX34-62C14ACX-048 CX34-62C14ACX-059 CX34-62C14ACX-060 CX34-62C

*TXV SUBSTITUTIONSUse this table to determine if the factory installed TXV in the indoor unit needs to be replaced.Outdoor Unit Model No. Indoor Coil Factory

TXVReplacement TXV

14ACX(-)(S)030 CX34-42 12J20 12J1814ACX(-)(S)030 CX34-43 12J20 12J1814ACX(-)(S)030 CX35-48 12J20 12J1814ACX(-)(S)036 CX34-31 12J18 12J19

* CX34 and CX35 coils - The factory installed expansion valve must be replaced with the expansion valve listed (ordered separately). If the combination is not listed above, the factory installed TXV is used.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 10

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-041-230 TXV 38500 15.5 12.5 C35-36B EL180UH090E48B 826793314ACX-041-230 TXV 38500 15.5 12.5 C35-36B EL180UH090XE48B 826793214ACX-041-230 TXV 38500 15.5 12.5 C35-48B EL180UH090E48B 826794014ACX-041-230 TXV 38500 15.5 12.5 C35-48B EL180UH090XE48B 826793814ACX-041-230 TXV 37800 14.5 12.2 C35-48B 826793414ACX-041-230 TXV 38500 16 13 C35-48C EL180UH090E60C 826793914ACX-041-230 TXV 38500 16 13 C35-48C EL180UH110E60C 826794114ACX-041-230 TXV 38500 16 13 C35-48C EL180UH110XE60C 826794214ACX-041-230 TXV 38500 15.5 12.5 C35-48C EL195UH090XE48C 826794614ACX-041-230 TXV 38500 15.5 12.5 C35-48C EL195UH110XE60C 826794514ACX-041-230 TXV 38500 15.5 12.5 C35-48C EL296UH090XE48C 826794414ACX-041-230 TXV 38500 15.5 12.5 C35-48C EL296UH110XE60C 826794314ACX-041-230 TXV 39000 16 13 C35-48C SL280UH090V60C 826793614ACX-041-230 TXV 39000 16 13 C35-48C SL280UH090XV60C 826794714ACX-041-230 TXV 38500 15.5 12.5 C35-48C SL280UH110V60C 826793714ACX-041-230 TXV 38500 15.5 12.5 C35-48C SL280UH110XV60C 826794814ACX-041-230 TXV 37800 14.5 12.2 C35-48C 826793514ACX-041-230 TXV 39000 16 13 C35-49C EL180UH090E60C 826795014ACX-041-230 TXV 39000 16 13 C35-49C EL180UH110E60C 826795114ACX-041-230 TXV 39000 16 13 C35-49C EL180UH110XE60C 826795214ACX-041-230 TXV 38500 16 13 C35-49C EL195UH090XE48C 826795614ACX-041-230 TXV 39000 15.5 12.5 C35-49C EL195UH110XE60C 826795514ACX-041-230 TXV 38500 16 13 C35-49C EL296UH090XE48C 826795414ACX-041-230 TXV 39000 15.5 12.5 C35-49C EL296UH110XE60C 826795314ACX-041-230 TXV 38500 14.7 12.5 C35-49C 826794914ACX-041-230 TXV 38000 15.5 12.5 C35-50/60C EL180UH090E60C 826795714ACX-041-230 TXV 38000 15.5 12.5 C35-50/60C EL180UH110E60C 826795814ACX-041-230 TXV 38000 15.5 12.5 C35-50/60C EL180UH110XE60C 826795914ACX-041-230 TXV 38000 15.5 12.5 C35-50/60C EL195UH090XE48C 826796314ACX-041-230 TXV 38500 15.5 12.5 C35-50/60C EL195UH110XE60C 826796214ACX-041-230 TXV 38000 15.5 12.5 C35-50/60C EL296UH090XE48C 826796114ACX-041-230 TXV 38500 15.5 12.5 C35-50/60C EL296UH110XE60C 826796014ACX-041-230 TXV 40000 16 13 C35-60C EL180UH090E60C 826796514ACX-041-230 TXV 40000 16 13 C35-60C EL180UH110E60C 826796614ACX-041-230 TXV 40000 16 13 C35-60C EL180UH110XE60C 826796714ACX-041-230 TXV 39500 16 13 C35-60C EL195UH090XE48C 826797114ACX-041-230 TXV 40000 16 13 C35-60C EL195UH110XE60C 826797014ACX-041-230 TXV 39500 16 13 C35-60C EL296UH090XE48C 826796914ACX-041-230 TXV 40000 16 13 C35-60C EL296UH110XE60C 826796814ACX-041-230 TXV 40000 16 13 C35-60C SLP98UH090XV48C 826796414ACX-041-230 TXV 39500 16 13 CBA27UHE-048 1025937914ACX-041-230 TXV 38000 14.5 12.5 CBX25UH-042 573278714ACX-041-230 TXV 39500 15.2 13 CBX25UH-048 573278814ACX-041-230 TXV 39000 16 13.5 CBX25UHV-042 697012914ACX-041-230 TXV 40000 16 14 CBX25UHV-048 697013014ACX-041-230 TXV 39000 16 13 CBX27UH-048 386909714ACX-041-230 TXV 39500 16 13 CBX32MV-048 386909814ACX-041-230 TXV 39000 16 13 CBX40UHV-048 386909914ACX-041-230 TXV 37600 15.5 13 CH23-51 EL180UH090E60C 5736596NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 11

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-041-230 TXV 37400 15.2 13 CH23-51 EL296UH110XV48C 568514014ACX-041-230 TXV 37200 15.5 13 CH23-51 SL280UH090V60C 551408014ACX-041-230 TXV 38000 15.5 13 CH23-65 EL180UH090E60C 573659814ACX-041-230 TXV 37600 15.5 13 CH23-65 SL280UH090V60C 551408214ACX-041-230 TXV 39500 16 13.5 CH33-43 EL180UH090E48B 573509714ACX-041-230 TXV 39000 16 13.5 CH33-43 EL180UH090E60C 573599114ACX-041-230 TXV 39500 16 13.5 CH33-43 EL180UH090XE48B 573706114ACX-041-230 TXV 39000 16 13.5 CH33-43 EL180UH110E60C 573781314ACX-041-230 TXV 39000 16 13.5 CH33-43 EL180UH110XE60C 573887414ACX-041-230 TXV 39000 15 12.7 CH33-43 EL296UH045XV36B 515307014ACX-041-230 TXV 39000 15.7 13 CH33-43 EL296UH090XV36C 505718714ACX-041-230 TXV 39000 15.7 13 CH33-43 EL296UH090XV48C 505718814ACX-041-230 TXV 39000 15.7 13 CH33-43 EL296UH090XV60C 505718914ACX-041-230 TXV 38500 16 13 CH33-43 EL296UH110XV60C 505719014ACX-041-230 TXV 39500 15.7 13 CH33-43 SL280UH090V36B 425379514ACX-041-230 TXV 39000 15.7 13 CH33-43 SLP98UH090XV36C 514045814ACX-041-230 TXV 39000 15.7 13 CH33-43 SLP98UH090XV48C 514045914ACX-041-230 TXV 39000 15.7 13 CH33-43 SLP98UH090XV60C 514046014ACX-041-230 TXV 38500 16 13 CH33-43 SLP98UH110XV60C 514046114ACX-041-230 TXV 39500 15.7 13 CH33-43B SL280UH090V48B 386910014ACX-041-230 TXV 39500 15.7 13 CH33-43B SL280UH090XV48B 403852114ACX-041-230 TXV 39000 15.7 13 CH33-43C EL195UH090XE48C 469385514ACX-041-230 TXV 38500 15.7 13 CH33-43C EL195UH110XE60C 469403014ACX-041-230 TXV 39000 15.7 13 CH33-43C EL296UH090XE48C 564724014ACX-041-230 TXV 38500 15.7 13 CH33-43C EL296UH110XE60C 564728814ACX-041-230 TXV 39000 15.7 13.5 CH33-43C EL296UH110XV48C 568513714ACX-041-230 TXV 39500 16 13 CH33-43C SL280UH090V60C 386910414ACX-041-230 TXV 39500 16 13 CH33-43C SL280UH090XV60C 423523614ACX-041-230 TXV 39000 15.7 13 CH33-43C SL280UH110V60C 386910514ACX-041-230 TXV 39000 15.7 13 CH33-43C SL280UH110XV60C 404007314ACX-041-230 TXV 38500 15.5 13.2 CH33-44/48 EL180UH090E48B 573509814ACX-041-230 TXV 38500 15.5 13.2 CH33-44/48 EL180UH090XE48B 573706314ACX-041-230 TXV 38000 14.7 12.5 CH33-44/48 EL296UH045XV36B 515307114ACX-041-230 TXV 38500 15.7 13.2 CH33-48 EL180UH090E60C 573599314ACX-041-230 TXV 38500 15.7 13.2 CH33-48 EL180UH110E60C 573781514ACX-041-230 TXV 38500 15.7 13.2 CH33-48 EL180UH110XE60C 573887514ACX-041-230 TXV 38500 15.2 13 CH33-48 EL296UH090XV36C 505719114ACX-041-230 TXV 38500 15.5 13 CH33-48 EL296UH090XV48C 505719214ACX-041-230 TXV 38500 15.2 13 CH33-48 SLP98UH090XV36C 514051514ACX-041-230 TXV 38500 15.5 13 CH33-48 SLP98UH090XV48C 514051614ACX-041-230 TXV 38500 15.5 13 CH33-48C EL195UH090XE48C 469385614ACX-041-230 TXV 39000 15.5 13.2 CH33-48C EL195UH110XE60C 469386914ACX-041-230 TXV 38500 15.5 13 CH33-48C EL296UH090XE48C 564724114ACX-041-230 TXV 39000 15.5 13.2 CH33-48C EL296UH110XE60C 564725414ACX-041-230 TXV 39000 15.5 13.2 CH33-48C EL296UH110XV48C 568513814ACX-041-230 TXV 39500 16 13.5 CH33-49 EL180UH090E60C 573599514ACX-041-230 TXV 39500 16 13.5 CH33-49 EL180UH110E60C 573781814ACX-041-230 TXV 39500 16 13.5 CH33-49 EL180UH110XE60C 573887714ACX-041-230 TXV 39000 15.7 13.5 CH33-49 EL195UH090XE48C 4693857NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 12

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-041-230 TXV 39500 15.7 13.5 CH33-49 EL195UH110XE60C 469387014ACX-041-230 TXV 39000 15.7 13.5 CH33-49 EL296UH090XE48C 564724214ACX-041-230 TXV 39500 15.7 13.5 CH33-49 EL296UH110XE60C 564725514ACX-041-230 TXV 39000 15.7 13.5 CH33-50/60C EL180UH090E60C 579575014ACX-041-230 TXV 39000 15.7 13.5 CH33-50/60C EL180UH110E60C 573782014ACX-041-230 TXV 39000 15.7 13.5 CH33-50/60C EL180UH110XE60C 573887914ACX-041-230 TXV 39000 15.7 13.5 CH33-50/60C EL195UH090XE48C 469385814ACX-041-230 TXV 39500 15.7 13.5 CH33-50/60C EL195UH110XE60C 469387114ACX-041-230 TXV 39000 15.7 13.5 CH33-50/60C EL296UH090XE48C 564724314ACX-041-230 TXV 39500 15.7 13.5 CH33-50/60C EL296UH110XE60C 564725614ACX-041-230 TXV 39500 15.7 13.5 CH33-50/60C EL296UH110XV48C 568513914ACX-041-230 TXV 39000 14.5 12.5 CH33-50/60C 425379814ACX-041-230 TXV 39500 16 13 CH35-42B EL180UH090E48B 716335314ACX-041-230 TXV 39000 15.1 13 CH35-42B EL296UH045XV36B 997335514ACX-041-230 TXV 39500 15.5 13 CH35-42B SL280UH090V36B 716335414ACX-041-230 TXV 39500 15.5 13 CH35-42B SL280UH090V48B 716335514ACX-041-230 TXV 39000 15.1 13 CH35-42B SLP98UH070XV36B 716335614ACX-041-230 TXV 39000 14.5 12.5 CH35-42B 716335014ACX-041-230 TXV 39000 16 13 CH35-42C EL180UH090E60C 716336414ACX-041-230 TXV 39000 16 13 CH35-42C EL180UH110E60C 716336514ACX-041-230 TXV 38500 15.5 13 CH35-42C EL195UH090XE48C 716335714ACX-041-230 TXV 39000 15.5 13 CH35-42C EL195UH110XE60C 716413814ACX-041-230 TXV 38500 15.5 13 CH35-42C EL296UH090XE48C 716336114ACX-041-230 TXV 38500 15.5 13 CH35-42C EL296UH090XV36C 716335814ACX-041-230 TXV 38500 15.5 13 CH35-42C EL296UH090XV48C 716335914ACX-041-230 TXV 39000 15.5 13 CH35-42C EL296UH090XV60C 716336014ACX-041-230 TXV 39000 15.5 13 CH35-42C EL296UH110XE60C 716414014ACX-041-230 TXV 39000 15.5 13 CH35-42C EL296UH110XV48C 716336214ACX-041-230 TXV 39000 16 13 CH35-42C EL296UH110XV60C 716336314ACX-041-230 TXV 39000 16 13 CH35-42C SL280UH090V60C 716336714ACX-041-230 TXV 39000 15.5 13 CH35-42C SL280UH110V60C 716336814ACX-041-230 TXV 38500 15.5 13 CH35-42C SLP98UH090XV36C 716336914ACX-041-230 TXV 38500 15.5 13 CH35-42C SLP98UH090XV48C 716337014ACX-041-230 TXV 39000 15.5 13 CH35-42C SLP98UH090XV60C 716337114ACX-041-230 TXV 38500 16 13 CH35-42C SLP98UH110XV60C 716337214ACX-041-230 TXV 38500 14.5 12.5 CH35-42C 716335114ACX-041-230 TXV 38500 15.5 13 CH35-48B EL180UH090E48B 716337614ACX-041-230 TXV 38000 14.5 12.5 CH35-48B EL296UH045XV36B 997335614ACX-041-230 TXV 38000 14.5 12.5 CH35-48B 716337314ACX-041-230 TXV 38500 15.5 13 CH35-48C EL180UH090E60C 716338314ACX-041-230 TXV 38500 15.5 13 CH35-48C EL180UH110E60C 716338414ACX-041-230 TXV 38000 15.5 13 CH35-48C EL195UH090XE48C 716337714ACX-041-230 TXV 38500 15.5 13 CH35-48C EL195UH110XE60C 716337814ACX-041-230 TXV 38500 15.1 13 CH35-48C EL296UH090XV36C 716337914ACX-041-230 TXV 38500 15.5 13 CH35-48C EL296UH090XV48C 716338014ACX-041-230 TXV 38500 15.5 13 CH35-48C EL296UH110XE60C 716338214ACX-041-230 TXV 38500 15.5 13 CH35-48C EL296UH110XV48C 716338114ACX-041-230 TXV 38500 15.5 13 CH35-48C SL280UH090V60C 716338514ACX-041-230 TXV 38500 15.5 13 CH35-48C SL280UH110V60C 7163386NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 13

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-041-230 TXV 38500 15.1 13 CH35-48C SLP98UH090XV36C 716338714ACX-041-230 TXV 38500 15.5 13 CH35-48C SLP98UH090XV48C 716338814ACX-041-230 TXV 38500 15.1 13 CH35-48C SLP98UH090XV60C 716413914ACX-041-230 TXV 38500 15.5 13 CH35-48C SLP98UH110XV60C 716338914ACX-041-230 TXV 38000 14.5 12.5 CH35-48C 716337414ACX-041-230 TXV 39000 16 13 CH35-51C EL180UH090E60C 716339614ACX-041-230 TXV 39000 16 13 CH35-51C EL180UH110E60C 716339714ACX-041-230 TXV 39000 15.5 13 CH35-51C EL195UH090XE48C 716339114ACX-041-230 TXV 39000 15.5 13 CH35-51C EL195UH110XE60C 716339214ACX-041-230 TXV 39000 15.5 13 CH35-51C EL296UH090XE48C 716339314ACX-041-230 TXV 39000 15.5 13 CH35-51C EL296UH110XE60C 716339514ACX-041-230 TXV 39500 15.5 13 CH35-51C EL296UH110XV48C 716339414ACX-041-230 TXV 39000 15.5 13 CH35-51C SLP98UH090XV36C 716339814ACX-041-230 TXV 39000 15.5 13 CH35-51C SLP98UH090XV48C 716339914ACX-041-230 TXV 39500 15.5 13 CH35-51C SLP98UH090XV60C 716340014ACX-041-230 TXV 39500 15.5 13 CH35-51C SLP98UH110XV60C 716340114ACX-041-230 TXV 38500 14.5 12.5 CH35-51C 716339014ACX-041-230 TXV 38500 15.7 13.5 CR33-50/60 EL180DF110E60C 573350514ACX-041-230 TXV 38000 15.5 13 CR33-50/60 EL195DF090XE48C 469384914ACX-041-230 TXV 38500 15.5 13.2 CR33-50/60 EL195DF110XE60C 469402914ACX-041-230 TXV 38000 15.5 13 CR33-50/60 EL296DF090XE48C 564728514ACX-041-230 TXV 36400 15.5 13 CR33-50/60 EL296DF090XV60C 553048814ACX-041-230 TXV 38500 15.5 13.2 CR33-50/60 EL296DF110XE60C 564728714ACX-041-230 TXV 38500 15 12.5 CR33-50/60 EL296DF110XV60C 717668014ACX-041-230 TXV 38500 16 13 CR33-50/60 SL280DF090V60C 386911414ACX-041-230 TXV 39000 16 13 CR33-50/60 SL280DF110V60C 386916614ACX-041-230 TXV 38500 15.5 12.5 CX35-36B EL180UH090E48B 826797314ACX-041-230 TXV 38500 15.5 12.5 CX35-36B EL180UH090XE48B 826797214ACX-041-230 TXV 38500 15.5 12.5 CX35-48B EL180UH090E48B 826797814ACX-041-230 TXV 38500 15.5 12.5 CX35-48B EL180UH090XE48B 826797614ACX-041-230 TXV 38000 14.5 12.2 CX35-48B 826797414ACX-041-230 TXV 38500 16 13 CX35-48C EL180UH090E60C 826797714ACX-041-230 TXV 38500 15.5 12.5 CX35-48C EL180UH110E60C 826797914ACX-041-230 TXV 38500 16 13 CX35-48C EL180UH110XE60C 826798014ACX-041-230 TXV 38500 15.5 12.5 CX35-48C EL195UH090XE48C 826799214ACX-041-230 TXV 38500 15.5 12.5 CX35-48C EL195UH110XE60C 826799114ACX-041-230 TXV 38500 15.5 12.5 CX35-48C EL296UH090XE48C 826798214ACX-041-230 TXV 38500 15.5 12.5 CX35-48C EL296UH090XV36C 826798714ACX-041-230 TXV 38500 15.5 12.5 CX35-48C EL296UH090XV48C 826798814ACX-041-230 TXV 38500 15.5 12.5 CX35-48C EL296UH090XV60C 826798914ACX-041-230 TXV 38500 15.5 12.5 CX35-48C EL296UH110XE60C 826798114ACX-041-230 TXV 38500 15.5 12.5 CX35-48C EL296UH110XV60C 826799014ACX-041-230 TXV 39000 16 13 CX35-48C SL280UH090V60C 826799514ACX-041-230 TXV 39000 16 13 CX35-48C SL280UH090XV60C 826799414ACX-041-230 TXV 38500 15.5 12.5 CX35-48C SL280UH110V60C 826799614ACX-041-230 TXV 38500 15.5 12.5 CX35-48C SL280UH110XV60C 826799314ACX-041-230 TXV 38500 15.5 12.5 CX35-48C SLP98UH090XV36C 826798414ACX-041-230 TXV 38500 15.5 12.5 CX35-48C SLP98UH090XV48C 826798514ACX-041-230 TXV 38500 15.5 12.5 CX35-48C SLP98UH090XV60C 8267986NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 14

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-041-230 TXV 38000 16 13 CX35-48C SLP98UH110XV60C 826798314ACX-041-230 TXV 38000 14.5 12.2 CX35-48C 826797514ACX-041-230 TXV 39000 16 13 CX35-49C EL180UH090E60C 826799914ACX-041-230 TXV 39000 16 13 CX35-49C EL180UH110E60C 826800014ACX-041-230 TXV 39000 16 13 CX35-49C EL180UH110XE60C 826800114ACX-041-230 TXV 38500 16 13 CX35-49C EL195UH090XE48C 826800614ACX-041-230 TXV 39000 15.5 12.5 CX35-49C EL195UH110XE60C 826800714ACX-041-230 TXV 38500 16 13 CX35-49C EL296UH090XE48C 826800214ACX-041-230 TXV 39000 15.5 12.5 CX35-49C EL296UH090XV48C 826799814ACX-041-230 TXV 39000 15.5 12.5 CX35-49C EL296UH110XE60C 826800314ACX-041-230 TXV 39500 16 13 CX35-49C EL296UH110XV60C 826800514ACX-041-230 TXV 39000 16 13 CX35-49C SL280UH090V60C 826800814ACX-041-230 TXV 39000 16 13 CX35-49C SL280UH110V60C 826800914ACX-041-230 TXV 38500 16 13 CX35-49C SLP98UH110XV60C 826800414ACX-041-230 TXV 38500 14.5 12.2 CX35-49C 826799714ACX-041-230 TXV 38000 15.5 12.5 CX35-50/60C EL180UH090E60C 826801014ACX-041-230 TXV 38000 15.5 12.5 CX35-50/60C EL180UH110E60C 826801114ACX-041-230 TXV 38000 15.5 12.5 CX35-50/60C EL180UH110XE60C 826801214ACX-041-230 TXV 38000 15.5 12.5 CX35-50/60C EL195UH090XE48C 826801614ACX-041-230 TXV 38500 15.5 12.5 CX35-50/60C EL195UH110XE60C 826801514ACX-041-230 TXV 38000 15.5 12.5 CX35-50/60C EL296UH090XE48C 826801314ACX-041-230 TXV 38500 15.5 12.5 CX35-50/60C EL296UH110XE60C 826801414ACX-041-230 TXV 40000 16 13 CX35-60C EL180UH090E60C 826801714ACX-041-230 TXV 40000 16 13 CX35-60C EL180UH110E60C 826801814ACX-041-230 TXV 40000 16 13 CX35-60C EL180UH110XE60C 826801914ACX-041-230 TXV 39500 16 13 CX35-60C EL195UH090XE48C 826803114ACX-041-230 TXV 40000 16 13 CX35-60C EL195UH110XE60C 826803014ACX-041-230 TXV 39500 16 13 CX35-60C EL296UH090XE48C 826802014ACX-041-230 TXV 39500 16 13 CX35-60C EL296UH090XV36C 826802714ACX-041-230 TXV 40000 16 13 CX35-60C EL296UH090XV48C 826802814ACX-041-230 TXV 40000 16 13 CX35-60C EL296UH090XV60C 826802914ACX-041-230 TXV 40000 16 13 CX35-60C EL296UH110XE60C 826802114ACX-041-230 TXV 40000 16 13 CX35-60C EL296UH110XV60C 826802614ACX-041-230 TXV 40000 16 13 CX35-60C SL280UH090V60C 826803214ACX-041-230 TXV 40000 16 13 CX35-60C SL280UH110V60C 826803314ACX-041-230 TXV 39500 16 13 CX35-60C SLP98UH090XV36C 826802214ACX-041-230 TXV 40000 16 13 CX35-60C SLP98UH090XV48C 826802314ACX-041-230 TXV 40000 16 13 CX35-60C SLP98UH090XV60C 826802414ACX-041-230 TXV 40000 16 13 CX35-60C SLP98UH110XV60C 826802514ACX-041-230 TXV 39000 14.5 12.5 CX38-49C 1054659614ACX-047-230 TXV 46000 15 12.5 C35-48B EL180UH090E48B 826739414ACX-047-230 TXV 46000 15 12.5 C35-48B EL180UH090XE48B 826739314ACX-047-230 TXV 46000 15 12.5 C35-49C EL180UH090E60C 826739514ACX-047-230 TXV 46500 15.1 12.5 C35-49C EL180UH110E60C 826739614ACX-047-230 TXV 46500 15.1 12.5 C35-49C EL180UH110XE60C 826739714ACX-047-230 TXV 46500 15.1 12.5 C35-49C EL195UH090XE48C 826740714ACX-047-230 TXV 46500 15.5 12.5 C35-49C EL195UH110XE60C 826740614ACX-047-230 TXV 46500 15.1 12.5 C35-49C EL296UH090XE48C 826739914ACX-047-230 TXV 47000 15.1 12.5 C35-49C EL296UH090XV48C 8267403NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 15

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-047-230 TXV 47000 15.1 12.5 C35-49C EL296UH090XV60C 826740414ACX-047-230 TXV 46500 15.5 12.5 C35-49C EL296UH110XE60C 826739814ACX-047-230 TXV 47000 15.1 12.5 C35-49C EL296UH110XV60C 826740514ACX-047-230 TXV 47000 15.5 12.5 C35-49C SL280UH090V60C 826740814ACX-047-230 TXV 47000 15.1 12.5 C35-49C SL280UH110V60C 826740914ACX-047-230 TXV 47000 15.1 12.5 C35-49C SLP98UH090XV48C 826740114ACX-047-230 TXV 47000 15.5 12.5 C35-49C SLP98UH090XV60C 826740214ACX-047-230 TXV 47000 15.1 12.5 C35-49C SLP98UH110XV60C 826740014ACX-047-230 TXV 45500 15.1 12.5 C35-50/60C EL180UH090E60C 826741014ACX-047-230 TXV 46000 14.5 12.2 C35-50/60C EL180UH110E60C 826741114ACX-047-230 TXV 46000 14.7 12.2 C35-50/60C EL180UH110XE60C 826741214ACX-047-230 TXV 45500 15 12.2 C35-50/60C EL195UH090XE48C 826741614ACX-047-230 TXV 45500 15 12.5 C35-50/60C EL195UH110XE60C 826741514ACX-047-230 TXV 45500 15 12.2 C35-50/60C EL296UH090XE48C 826741414ACX-047-230 TXV 45500 15 12.5 C35-50/60C EL296UH110XE60C 826741314ACX-047-230 TXV 47500 16 13 C35-60C EL180UH090E60C 826742014ACX-047-230 TXV 47500 16 13 C35-60C EL180UH110E60C 826742114ACX-047-230 TXV 47500 16 13 C35-60C EL180UH110XE60C 826742214ACX-047-230 TXV 47500 15.5 12.5 C35-60C EL195UH090XE48C 826742614ACX-047-230 TXV 47500 15.5 12.5 C35-60C EL195UH110XE60C 826742514ACX-047-230 TXV 47500 15.5 12.5 C35-60C EL296UH090XE48C 826742414ACX-047-230 TXV 47500 15.5 12.5 C35-60C EL296UH110XE60C 826742314ACX-047-230 TXV 48000 16 13 C35-60C SL280UH090V60C 826742714ACX-047-230 TXV 48000 16 13 C35-60C SL280UH090XV60C 826741814ACX-047-230 TXV 47500 16 13 C35-60C SL280UH110V60C 826742814ACX-047-230 TXV 47500 16 13 C35-60C SL280UH110XV60C 826741914ACX-047-230 TXV 47000 14.5 12.2 C35-60C 826741714ACX-047-230 TXV 47500 15.5 12.5 C35-60D EL180UH135E60D 826742914ACX-047-230 TXV 47000 15.5 12.5 C35-60D EL195UH135XE60D 826743114ACX-047-230 TXV 47000 15.5 12.5 C35-60D EL296UH135XE60D 826743014ACX-047-230 TXV 47000 16 13 CBA27UHE-048 1025938214ACX-047-230 TXV 46500 15.1 12.5 CBX25UH-048 573279014ACX-047-230 TXV 47000 16 13 CBX25UHV-048 697013214ACX-047-230 TXV 46500 16 13 CBX27UH-048 386917414ACX-047-230 TXV 46000 16 13 CBX32MV-060 386917514ACX-047-230 TXV 46000 16 13 CBX40UHV-060 386917614ACX-047-230 TXV 44000 15 12.2 CH23-65 EL180UH090E60C 573692814ACX-047-230 TXV 47500 15.5 12.7 CH33-43 EL180UH090E48B 573511314ACX-047-230 TXV 46000 15.2 12.7 CH33-43 EL180UH090E60C 573601714ACX-047-230 TXV 47500 15.5 12.7 CH33-43 EL180UH090XE48B 573707714ACX-047-230 TXV 46500 15 12.5 CH33-43 EL180UH110E60C 573784114ACX-047-230 TXV 46500 15 12.5 CH33-43 EL180UH110XE60C 573891814ACX-047-230 TXV 47000 15.2 12.7 CH33-43 SL280UH090V48B 401667814ACX-047-230 TXV 46500 15.2 12.7 CH33-43 SL280UH090V60C 425383014ACX-047-230 TXV 47000 15.2 12.7 CH33-43 SL280UH090XV48B 403853514ACX-047-230 TXV 46000 15.2 12.5 CH33-43 SL280UH110V60C 425383114ACX-047-230 TXV 46000 15 12.5 CH33-43C EL195UH090XE48C 469392314ACX-047-230 TXV 46000 15.2 12.7 CH33-43C EL195UH110XE60C 469393514ACX-047-230 TXV 46000 15 12.5 CH33-43C EL296UH090XE48C 5647268NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 16

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-047-230 TXV 46000 15.2 12.7 CH33-43C EL296UH110XE60C 564723114ACX-047-230 TXV 46000 14.25 12 CH33-43C 742664514ACX-047-230 TXV 45500 14.7 12.2 CH33-44/48 EL180UH090E48B 573511514ACX-047-230 TXV 45500 14.7 12.2 CH33-44/48 EL180UH090XE48B 573707914ACX-047-230 TXV 45000 14.5 12 CH33-44/48 SL280UH090V48B 401667914ACX-047-230 TXV 45000 14.5 12 CH33-44/48 SL280UH090XV48B 403853614ACX-047-230 TXV 45500 15.2 12.5 CH33-48 EL180UH090E60C 573602014ACX-047-230 TXV 46500 14.7 12.2 CH33-48 EL180UH110E60C 573784314ACX-047-230 TXV 46500 14.7 12.2 CH33-48 EL180UH110XE60C 573892114ACX-047-230 TXV 46000 14.7 12.5 CH33-48 EL296UH090XV48C 505727514ACX-047-230 TXV 46000 14.7 12.2 CH33-48 EL296UH090XV60C 505727614ACX-047-230 TXV 46000 14.7 12.5 CH33-48 EL296UH110XV60C 505727714ACX-047-230 TXV 46000 15.2 12.5 CH33-48 SL280UH090V60C 386918014ACX-047-230 TXV 46000 15.2 12.5 CH33-48 SL280UH090XV60C 423524214ACX-047-230 TXV 46000 15 12.5 CH33-48 SL280UH110V60C 386918114ACX-047-230 TXV 46000 15 12.5 CH33-48 SL280UH110XV60C 404014314ACX-047-230 TXV 46000 14.7 12.5 CH33-48 SLP98UH090XV48C 514046514ACX-047-230 TXV 46000 14.7 12.2 CH33-48 SLP98UH090XV60C 514046614ACX-047-230 TXV 46000 14.7 12.5 CH33-48 SLP98UH110XV60C 514046714ACX-047-230 TXV 45500 14.7 12.5 CH33-48C EL195UH090XE48C 469392414ACX-047-230 TXV 45500 14.7 12.5 CH33-48C EL195UH110XE60C 469393614ACX-047-230 TXV 45500 14.7 12.5 CH33-48C EL296UH090XE48C 564726914ACX-047-230 TXV 45500 14.7 12.5 CH33-48C EL296UH110XE60C 564723214ACX-047-230 TXV 45500 14.25 12 CH33-48C 742664614ACX-047-230 TXV 46500 15.5 12.7 CH33-49 EL180UH090E60C 573602214ACX-047-230 TXV 47500 15.2 12.7 CH33-49 EL180UH110E60C 573784514ACX-047-230 TXV 47500 15.2 12.7 CH33-49 EL180UH110XE60C 573892214ACX-047-230 TXV 46500 15.2 12.7 CH33-49 EL195UH090XE48C 469392514ACX-047-230 TXV 46500 15.2 12.7 CH33-49 EL195UH110XE60C 469393714ACX-047-230 TXV 46500 15.2 12.7 CH33-49 EL296UH090XE48C 564727014ACX-047-230 TXV 47000 15.2 12.7 CH33-49 EL296UH090XV48C 505728414ACX-047-230 TXV 47000 15.2 12.7 CH33-49 EL296UH090XV60C 505728514ACX-047-230 TXV 46500 15.2 12.7 CH33-49 EL296UH110XE60C 564723314ACX-047-230 TXV 47000 15.2 12.7 CH33-49 EL296UH110XV60C 505728614ACX-047-230 TXV 47000 15.2 12.7 CH33-49 SLP98UH090XV48C 514053714ACX-047-230 TXV 47000 15.2 12.7 CH33-49 SLP98UH090XV60C 514053814ACX-047-230 TXV 47000 15.2 12.7 CH33-49 SLP98UH110XV60C 514053914ACX-047-230 TXV 46500 14.5 12 CH33-49 742665214ACX-047-230 TXV 46500 15.5 12.7 CH33-50/60C EL180UH090E60C 573602414ACX-047-230 TXV 47000 15 12.5 CH33-50/60C EL180UH110E60C 573784714ACX-047-230 TXV 47000 15 12.5 CH33-50/60C EL180UH110XE60C 573892514ACX-047-230 TXV 46500 15.2 12.7 CH33-50/60C EL195UH090XE48C 469392614ACX-047-230 TXV 46500 15.2 12.7 CH33-50/60C EL195UH110XE60C 469393814ACX-047-230 TXV 46500 15.2 12.7 CH33-50/60C EL296UH090XE48C 564727114ACX-047-230 TXV 46500 15.2 12.7 CH33-50/60C EL296UH110XE60C 564723414ACX-047-230 TXV 46500 14.5 12.2 CH33-50/60C 425383514ACX-047-230 TXV 46500 15.5 12.7 CH33-60D EL180UH135E60D 574607014ACX-047-230 TXV 46500 15 12.5 CH33-60D EL195UH135XE60D 469394514ACX-047-230 TXV 46500 15 12.5 CH33-60D EL296UH135XE60D 5647281NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 17

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-047-230 TXV 46000 14.25 12 CH33-60D 742664714ACX-047-230 TXV 47000 15.7 13 CH33-62D EL180UH135E60D 574607114ACX-047-230 TXV 47000 15.2 12.7 CH33-62D EL195UH135XE60D 469394614ACX-047-230 TXV 47000 15.2 12.7 CH33-62D EL296UH135XE60D 564728214ACX-047-230 TXV 46500 14.5 12 CH33-62D 742664814ACX-047-230 TXV 47500 15.5 12.5 CH35-42B EL180UH090E48B 716395214ACX-047-230 TXV 47500 15 12.5 CH35-42B SL280UH090XV48B 716395514ACX-047-230 TXV 47000 14.5 12 CH35-42B 716395714ACX-047-230 TXV 46000 15.1 12.5 CH35-42C EL180UH090E60C 716397014ACX-047-230 TXV 47000 15 12.5 CH35-42C EL180UH110E60C 716397214ACX-047-230 TXV 46000 15.1 12.5 CH35-42C EL195UH090XE48C 716396114ACX-047-230 TXV 46000 15.1 12.5 CH35-42C EL195UH110XE60C 716396314ACX-047-230 TXV 46000 15.1 12.5 CH35-42C EL296UH090XE48C 716396514ACX-047-230 TXV 46000 15.1 12.5 CH35-42C EL296UH110XE60C 716396814ACX-047-230 TXV 46500 15.1 12.5 CH35-42C SL280UH090V60C 716397414ACX-047-230 TXV 46500 15.1 12.5 CH35-42C SL280UH110V60C 716397614ACX-047-230 TXV 46500 15 12.5 CH35-42C SLP98UH090XV48C 716397814ACX-047-230 TXV 46500 15 12.5 CH35-42C SLP98UH090XV60C 716398114ACX-047-230 TXV 46500 15 12.5 CH35-42C SLP98UH110XV60C 716398214ACX-047-230 TXV 46000 14.5 12 CH35-42C 716395914ACX-047-230 TXV 46000 15 12.5 CH35-48B EL180UH090E48B 716398514ACX-047-230 TXV 46000 14.5 12 CH35-48B SL280UH090V48B 716398814ACX-047-230 TXV 46000 14.5 12 CH35-48B 716399114ACX-047-230 TXV 46000 15.1 12.5 CH35-48C EL180UH090E60C 716401414ACX-047-230 TXV 46500 15 12.5 CH35-48C EL180UH110E60C 716401614ACX-047-230 TXV 46000 15 12.5 CH35-48C EL195UH090XE48C 716399514ACX-047-230 TXV 46000 15.1 12.5 CH35-48C EL195UH110XE60C 716399814ACX-047-230 TXV 46000 15 12.5 CH35-48C EL296UH090XE48C 716400114ACX-047-230 TXV 46000 15 12.5 CH35-48C EL296UH090XV48C 716400314ACX-047-230 TXV 46000 15 12 CH35-48C EL296UH090XV60C 716400614ACX-047-230 TXV 46000 15.1 12.5 CH35-48C EL296UH110XE60C 716400914ACX-047-230 TXV 46000 15 12.5 CH35-48C EL296UH110XV60C 716401114ACX-047-230 TXV 46500 15.1 12.5 CH35-48C SL280UH090V60C 716401914ACX-047-230 TXV 46000 15.1 12.5 CH35-48C SL280UH110V60C 716402114ACX-047-230 TXV 46000 15 12.5 CH35-48C SLP98UH090XV48C 716402514ACX-047-230 TXV 46000 15 12 CH35-48C SLP98UH090XV60C 716402714ACX-047-230 TXV 46000 15 12.5 CH35-48C SLP98UH110XV60C 716403014ACX-047-230 TXV 46000 14.5 12 CH35-48C 716399314ACX-047-230 TXV 47000 15.5 13 CH35-51C EL180UH090E60C 716405414ACX-047-230 TXV 47500 15.1 12.5 CH35-51C EL180UH110E60C 716405614ACX-047-230 TXV 47000 15.1 12.5 CH35-51C EL195UH090XE48C 716403514ACX-047-230 TXV 47000 15.1 12.5 CH35-51C EL195UH110XE60C 716403814ACX-047-230 TXV 47000 15.1 12.5 CH35-51C EL296UH090XE48C 716404214ACX-047-230 TXV 47000 15.1 12.5 CH35-51C EL296UH090XV48C 716404414ACX-047-230 TXV 47000 15.1 12.5 CH35-51C EL296UH090XV60C 716404714ACX-047-230 TXV 47000 15.1 12.5 CH35-51C EL296UH110XE60C 716404914ACX-047-230 TXV 47000 15.1 12.5 CH35-51C EL296UH110XV60C 716405214ACX-047-230 TXV 47000 15.5 12.5 CH35-51C SL280UH090V60C 716405914ACX-047-230 TXV 47000 15.1 12.5 CH35-51C SL280UH110V60C 7164062NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 18

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-047-230 TXV 47000 15.1 12.5 CH35-51C SLP98UH090XV48C 716406514ACX-047-230 TXV 47000 15.1 12.5 CH35-51C SLP98UH090XV60C 716406714ACX-047-230 TXV 47000 15.1 12.5 CH35-51C SLP98UH110XV60C 716407014ACX-047-230 TXV 47000 14.5 12 CH35-51C 716403314ACX-047-230 TXV 47500 15.5 13 CH35-60D EL180UH135E60D 716408014ACX-047-230 TXV 47000 15.1 12.5 CH35-60D EL195UH135XE60D 716407514ACX-047-230 TXV 47000 15.1 12.5 CH35-60D EL296UH135XE60D 716407814ACX-047-230 TXV 47000 15.5 13 CH35-60D SL280UH135V60D 716408314ACX-047-230 TXV 47000 15.5 12.5 CH35-60D SLP98UH135XV60D 1004042514ACX-047-230 TXV 47000 14.5 12 CH35-60D 716407314ACX-047-230 TXV 45000 15.2 12.5 CR33-50/60 EL180DF110E60C 573350714ACX-047-230 TXV 44500 14.7 12.2 CR33-50/60 EL195DF090XE48C 469391714ACX-047-230 TXV 44500 15.2 12.2 CR33-50/60 EL195DF110XE60C 469391814ACX-047-230 TXV 44500 14.7 12.2 CR33-50/60 EL296DF090XE48C 564726214ACX-047-230 TXV 44500 15.2 12.2 CR33-50/60 EL296DF110XE60C 564726314ACX-047-230 TXV 45500 15.7 13 CR33-50/60 SL280DF090V60C 386918614ACX-047-230 TXV 45500 15.7 13 CR33-50/60 SL280DF110V60C 386918714ACX-047-230 TXV 46000 15 12.5 CX35-48B EL180UH090E48B 826743314ACX-047-230 TXV 46000 15 12.5 CX35-48B EL180UH090XE48B 826743214ACX-047-230 TXV 46000 14.5 12.2 CX35-48B SL280UH090V48B 826743514ACX-047-230 TXV 46000 14.5 12.2 CX35-48B SL280UH090XV48B 826743414ACX-047-230 TXV 46500 15.1 12.5 CX35-49C EL180UH110E60C 826743614ACX-047-230 TXV 46500 15.1 12.5 CX35-49C EL180UH110XE60C 826743714ACX-047-230 TXV 46500 15.1 12.5 CX35-49C EL195UH090XE48C 826744714ACX-047-230 TXV 46500 15.5 12.5 CX35-49C EL195UH110XE60C 826744614ACX-047-230 TXV 46500 15.1 12.5 CX35-49C EL296UH090XE48C 826743814ACX-047-230 TXV 47000 15.1 12.5 CX35-49C EL296UH090XV48C 826744314ACX-047-230 TXV 47000 15.1 12.5 CX35-49C EL296UH090XV60C 826744414ACX-047-230 TXV 46500 15.5 12.5 CX35-49C EL296UH110XE60C 826743914ACX-047-230 TXV 47000 15.1 12.5 CX35-49C EL296UH110XV60C 826744514ACX-047-230 TXV 47000 15.5 12.5 CX35-49C SL280UH090V60C 826744814ACX-047-230 TXV 47000 15.1 12.5 CX35-49C SL280UH110V60C 826744914ACX-047-230 TXV 47000 15 12.5 CX35-49C SLP98UH090XV48C 826744114ACX-047-230 TXV 47000 15.1 12.5 CX35-49C SLP98UH090XV60C 826744214ACX-047-230 TXV 47000 15.1 12.5 CX35-49C SLP98UH110XV60C 826744014ACX-047-230 TXV 45500 15.1 12.5 CX35-50/60C EL180UH090E60C 826745014ACX-047-230 TXV 46000 14.5 12.2 CX35-50/60C EL180UH110E60C 826745114ACX-047-230 TXV 46000 14.7 12.2 CX35-50/60C EL180UH110XE60C 826745214ACX-047-230 TXV 45500 15 12.2 CX35-50/60C EL195UH090XE48C 826745614ACX-047-230 TXV 45500 15 12.5 CX35-50/60C EL195UH110XE60C 826745514ACX-047-230 TXV 45500 15 12.5 CX35-50/60C EL296UH090XE48C 826745314ACX-047-230 TXV 45500 15 12.2 CX35-50/60C EL296UH110XE60C 826745414ACX-047-230 TXV 47500 16 13 CX35-60C EL180UH090E60C 826746014ACX-047-230 TXV 47500 16 13 CX35-60C EL180UH110E60C 826746114ACX-047-230 TXV 47500 16 13 CX35-60C EL180UH110XE60C 826746214ACX-047-230 TXV 47500 15.5 12.5 CX35-60C EL195UH090XE48C 826746614ACX-047-230 TXV 47500 15.5 12.5 CX35-60C EL195UH110XE60C 826746514ACX-047-230 TXV 47500 15.5 12.5 CX35-60C EL296UH090XE48C 826746314ACX-047-230 TXV 47500 15.5 12.5 CX35-60C EL296UH110XE60C 8267464NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 19

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-047-230 TXV 48000 16 13 CX35-60C SL280UH090V60C 826746714ACX-047-230 TXV 48000 16 13 CX35-60C SL280UH090XV60C 826745814ACX-047-230 TXV 47500 16 13 CX35-60C SL280UH110V60C 826746814ACX-047-230 TXV 47500 16 13 CX35-60C SL280UH110XV60C 826745914ACX-047-230 TXV 47000 14.5 12.2 CX35-60C 826745714ACX-047-230 TXV 47500 15.5 12.5 CX35-60D EL180UH135E60D 826746914ACX-047-230 TXV 47000 15.5 12.5 CX35-60D EL195UH135XE60D 826747114ACX-047-230 TXV 47000 15.5 12.5 CX35-60D EL296UH135XE60D 826747014ACX-047-230 TXV 47000 14.7 12.5 CX38-62C 1054684614ACX-048-230 TXV 48000 14.25 12 C35-48B EL180UH090E48B 913878214ACX-048-230 TXV 48000 14.25 12 C35-48B EL180UH090XE48B 913878114ACX-048-230 TXV 48000 14.5 12 C35-48C EL180UH090E60C 913876914ACX-048-230 TXV 47500 14.5 12 C35-48C EL180UH110E60C 913877014ACX-048-230 TXV 47500 14.5 12 C35-48C EL180UH110XE60C 913877114ACX-048-230 TXV 48000 14.5 12 C35-48C EL195UH090XE48C 913877214ACX-048-230 TXV 48000 14.5 12 C35-48C EL195UH110XE60C 913876214ACX-048-230 TXV 48000 14.5 12 C35-48C EL296UH090XE48C 913876114ACX-048-230 TXV 48000 14 12 C35-48C EL296UH090XV48C 913876414ACX-048-230 TXV 48000 14 12 C35-48C EL296UH090XV60C 913877814ACX-048-230 TXV 48000 14.5 12 C35-48C EL296UH110XE60C 913876314ACX-048-230 TXV 48000 14.5 12 C35-48C EL296UH110XV48C 913876714ACX-048-230 TXV 48000 14 12 C35-48C EL296UH110XV60C 913876814ACX-048-230 TXV 48000 14.5 12 C35-48C SL280UH090V60C 913877314ACX-048-230 TXV 48000 14.5 12 C35-48C SL280UH090XV60C 913878414ACX-048-230 TXV 48000 14.5 12 C35-48C SL280UH110V60C 913877414ACX-048-230 TXV 48000 14.5 12 C35-48C SL280UH110XV60C 913877514ACX-048-230 TXV 48000 14 12 C35-48C SLP98UH090XV48C 913877614ACX-048-230 TXV 48000 14 12 C35-48C SLP98UH090XV60C 913877714ACX-048-230 TXV 48000 14.25 12 C35-48C SLP98UH110XV60C 913878314ACX-048-230 TXV 48000 15 12.5 C35-49C EL180UH090E60C 913875914ACX-048-230 TXV 48000 14 12 C35-49C EL180UH110E60C 913876014ACX-048-230 TXV 48000 14 12 C35-49C EL180UH110XE60C 913874914ACX-048-230 TXV 48000 14.5 12 C35-49C EL195UH090XE48C 913874614ACX-048-230 TXV 48000 14.5 12 C35-49C EL195UH110XE60C 913875314ACX-048-230 TXV 48000 14.5 12 C35-49C EL296UH090XE48C 913875214ACX-048-230 TXV 48000 14.5 12 C35-49C EL296UH090XV48C 913874314ACX-048-230 TXV 48000 14.5 12 C35-49C EL296UH090XV60C 913874414ACX-048-230 TXV 48000 14.5 12 C35-49C EL296UH110XE60C 913875414ACX-048-230 TXV 48000 14.5 12 C35-49C EL296UH110XV48C 913874514ACX-048-230 TXV 48000 14.5 12 C35-49C EL296UH110XV60C 913875814ACX-048-230 TXV 48000 15 12.5 C35-49C SL280UH090V60C 913875014ACX-048-230 TXV 48000 15 12.5 C35-49C SL280UH090XV60C 913875114ACX-048-230 TXV 48000 15 12.5 C35-49C SL280UH110V60C 913876514ACX-048-230 TXV 48000 15 12.5 C35-49C SL280UH110XV60C 913876614ACX-048-230 TXV 48000 14.5 12 C35-49C SLP98UH090XV48C 913875514ACX-048-230 TXV 48000 14.5 12 C35-49C SLP98UH090XV60C 913875614ACX-048-230 TXV 48000 14.5 12 C35-49C SLP98UH110XV60C 913875714ACX-048-230 TXV 48000 14 11.7 C35-49C 913861314ACX-048-230 TXV 47500 14.5 12 C35-50/60C EL180UH090E60C 9138741NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 20

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-048-230 TXV 48000 14 11.7 C35-50/60C EL180UH110E60C 913874214ACX-048-230 TXV 48000 14 11.7 C35-50/60C EL180UH110XE60C 913873114ACX-048-230 TXV 47500 14.25 12 C35-50/60C EL195UH090XE48C 913872814ACX-048-230 TXV 47500 14.25 12 C35-50/60C EL195UH110XE60C 913873514ACX-048-230 TXV 47500 14.25 12 C35-50/60C EL296UH090XE48C 913873414ACX-048-230 TXV 47500 14 11.7 C35-50/60C EL296UH090XV48C 913872514ACX-048-230 TXV 47500 14 11.7 C35-50/60C EL296UH090XV60C 913872614ACX-048-230 TXV 47500 14.25 12 C35-50/60C EL296UH110XE60C 913873614ACX-048-230 TXV 47500 14.25 11.7 C35-50/60C EL296UH110XV48C 913872714ACX-048-230 TXV 47500 14 11.7 C35-50/60C EL296UH110XV60C 913874014ACX-048-230 TXV 47500 14.25 12 C35-50/60C SL280UH090V60C 913873214ACX-048-230 TXV 47500 14.25 12 C35-50/60C SL280UH090XV60C 913873314ACX-048-230 TXV 47500 14.25 12 C35-50/60C SL280UH110V60C 913874714ACX-048-230 TXV 47500 14.25 12 C35-50/60C SL280UH110XV60C 913874814ACX-048-230 TXV 47500 14 11.7 C35-50/60C SLP98UH090XV48C 913873714ACX-048-230 TXV 47500 14 11.7 C35-50/60C SLP98UH090XV60C 913873814ACX-048-230 TXV 47500 14 11.7 C35-50/60C SLP98UH110XV60C 913873914ACX-048-230 TXV 48000 15.1 12.5 C35-60C EL180UH090E60C 913941914ACX-048-230 TXV 48000 15 12.5 C35-60C EL180UH110E60C 913872414ACX-048-230 TXV 48000 15 12.5 C35-60C EL180UH110XE60C 913871614ACX-048-230 TXV 48000 14.5 12.5 C35-60C EL195UH090XE48C 913871314ACX-048-230 TXV 48000 15 12.5 C35-60C EL195UH110XE60C 913871814ACX-048-230 TXV 48000 14.5 12.5 C35-60C EL296UH090XE48C 913871714ACX-048-230 TXV 48000 14.5 12 C35-60C EL296UH090XV48C 913871014ACX-048-230 TXV 48000 14.5 12 C35-60C EL296UH090XV60C 913871114ACX-048-230 TXV 48000 15 12.5 C35-60C EL296UH110XE60C 913871914ACX-048-230 TXV 48000 15 12.5 C35-60C EL296UH110XV48C 913871214ACX-048-230 TXV 48000 14.5 12.5 C35-60C EL296UH110XV60C 913872314ACX-048-230 TXV 48000 15.1 12.5 C35-60C SL280UH090V60C 913941714ACX-048-230 TXV 48000 15.1 12.5 C35-60C SL280UH090XV60C 913941814ACX-048-230 TXV 48000 15 12.5 C35-60C SL280UH110V60C 913872914ACX-048-230 TXV 48000 15 12.5 C35-60C SL280UH110XV60C 913873014ACX-048-230 TXV 48000 14.5 12 C35-60C SLP98UH090XV48C 913872014ACX-048-230 TXV 48000 14.5 12 C35-60C SLP98UH090XV60C 913872114ACX-048-230 TXV 48000 14.5 12.5 C35-60C SLP98UH110XV60C 913872214ACX-048-230 TXV 48000 14 11.7 C35-60C 913861414ACX-048-230 TXV 48000 15 12.5 C35-60D EL180UH135E60D 913870414ACX-048-230 TXV 48000 14.25 12 C35-60D EL195UH135XE60D 913870714ACX-048-230 TXV 48000 14.25 12 C35-60D EL296UH135XE60D 913871414ACX-048-230 TXV 48000 14.5 12 C35-60D EL296UH135XV60D 913871514ACX-048-230 TXV 48000 15 12.5 C35-60D SL280UH135V60D 913870514ACX-048-230 TXV 48000 14.5 12 C35-60D SLP98UH135XV60D 913870614ACX-048-230 TXV 48000 14 11.7 C35-60D 913861514ACX-048-230 TXV 48000 14.5 12.2 CBA27UHE-048 1025938314ACX-048-230 TXV 48000 15 12.5 CBA27UHE-060 1025938414ACX-048-230 TXV 48000 14.5 12 CBX25UH-048 913906614ACX-048-230 TXV 48000 14.5 12.5 CBX25UHV-048 913906714ACX-048-230 TXV 48000 14.5 12 CBX27UH-048 913906814ACX-048-230 TXV 48000 15 12.5 CBX27UH-060 9139069NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 21

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-048-230 TXV 48000 14.25 12 CBX32M-048 913905814ACX-048-230 TXV 48000 14.25 12 CBX32M-060 913905914ACX-048-230 TXV 48000 14.25 12 CBX32MV-048 913906014ACX-048-230 TXV 48000 14.5 12 CBX32MV-060 913906114ACX-048-230 TXV 47500 14.5 12 CBX40UHV-048 913906214ACX-048-230 TXV 48000 14.5 12 CBX40UHV-060 913906314ACX-048-230 TXV 46000 14 11.7 CH23-51 EL180UH090E48B 913905214ACX-048-230 TXV 45500 14 11.7 CH23-51 EL180UH110E60C 913905314ACX-048-230 TXV 45500 14 11.7 CH23-51 EL180UH110XE60C 913905414ACX-048-230 TXV 47000 14.25 11.7 CH23-65 EL180UH090E48B 913905514ACX-048-230 TXV 47000 14.5 12 CH23-65 EL180UH090E60C 913905714ACX-048-230 TXV 47000 14.25 11.7 CH23-65 EL180UH090XE48B 913905614ACX-048-230 TXV 46500 14.5 12 CH23-65 EL180UH110E60C 913904614ACX-048-230 TXV 46500 14.5 12 CH23-65 EL180UH110XE60C 913904714ACX-048-230 TXV 48000 15 12.5 CH23-68 EL180UH135E60D 913905014ACX-048-230 TXV 48000 14.5 12 CH23-68 EL195UH135XE60D 913904814ACX-048-230 TXV 48000 14.5 12 CH23-68 EL296UH135XE60D 913904914ACX-048-230 TXV 48000 14 11.7 CH23-68 913860714ACX-048-230 TXV 48000 14.5 12 CH33-43B EL180UH090E48B 913905114ACX-048-230 TXV 48000 14.5 12 CH33-43B EL180UH090XE48B 913904014ACX-048-230 TXV 48000 14.5 12 CH33-43C EL180UH090E60C 913903714ACX-048-230 TXV 48000 14.25 12 CH33-43C EL180UH110E60C 913903814ACX-048-230 TXV 48000 14.25 12 CH33-43C EL180UH110XE60C 913903914ACX-048-230 TXV 47500 14.25 12 CH33-43C EL195UH090XE48C 913904114ACX-048-230 TXV 48000 14.5 12 CH33-43C EL195UH110XE60C 913904314ACX-048-230 TXV 47500 14.25 12 CH33-43C EL296UH090XE48C 913904214ACX-048-230 TXV 48000 14.25 12 CH33-43C EL296UH090XV48C 913904514ACX-048-230 TXV 48000 14.25 11.7 CH33-43C EL296UH090XV60C 913903414ACX-048-230 TXV 48000 14.5 12 CH33-43C EL296UH110XE60C 913904414ACX-048-230 TXV 48000 14.25 12 CH33-43C EL296UH110XV48C 913903514ACX-048-230 TXV 48000 14.25 12 CH33-43C EL296UH110XV60C 913903614ACX-048-230 TXV 48000 14.5 12 CH33-43C SL280UH090V60C 913902814ACX-048-230 TXV 48000 14.5 12 CH33-43C SL280UH090XV60C 913902914ACX-048-230 TXV 48000 14.5 12 CH33-43C SL280UH110V60C 913903014ACX-048-230 TXV 48000 14.5 12 CH33-43C SL280UH110XV60C 913903114ACX-048-230 TXV 48000 14.25 12 CH33-43C SLP98UH090XV48C 913903214ACX-048-230 TXV 48000 14.25 11.7 CH33-43C SLP98UH090XV60C 913903314ACX-048-230 TXV 48000 14.25 12 CH33-43C SLP98UH110XV60C 913902214ACX-048-230 TXV 47000 14 11.7 CH33-44/48B EL180UH090E48B 913902314ACX-048-230 TXV 47000 14 11.7 CH33-44/48B EL180UH090XE48B 913902414ACX-048-230 TXV 47500 14.5 12 CH33-48C EL180UH090E60C 913902114ACX-048-230 TXV 48000 14 12 CH33-48C EL180UH110E60C 913901014ACX-048-230 TXV 48000 14 12 CH33-48C EL180UH110XE60C 913901114ACX-048-230 TXV 47500 14 12 CH33-48C EL195UH090XE48C 913902514ACX-048-230 TXV 47500 14 12 CH33-48C EL195UH110XE60C 913902714ACX-048-230 TXV 47500 14 12 CH33-48C EL296UH090XE48C 913902614ACX-048-230 TXV 47500 14 11.7 CH33-48C EL296UH090XV48C 913901714ACX-048-230 TXV 47500 14 11.7 CH33-48C EL296UH090XV60C 913901814ACX-048-230 TXV 47500 14 12 CH33-48C EL296UH110XE60C 9139016NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 22

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-048-230 TXV 47500 14.25 11.7 CH33-48C EL296UH110XV48C 913901914ACX-048-230 TXV 47500 14 11.7 CH33-48C EL296UH110XV60C 913902014ACX-048-230 TXV 48000 14.25 12 CH33-48C SL280UH090V60C 913901214ACX-048-230 TXV 48000 14.25 12 CH33-48C SL280UH090XV60C 913901314ACX-048-230 TXV 47500 14.25 12 CH33-48C SL280UH110V60C 913901414ACX-048-230 TXV 47500 14.25 12 CH33-48C SL280UH110XV60C 913901514ACX-048-230 TXV 47500 14 11.7 CH33-48C SLP98UH090XV48C 913900414ACX-048-230 TXV 47500 14 11.7 CH33-48C SLP98UH090XV60C 913900514ACX-048-230 TXV 47500 14 11.7 CH33-48C SLP98UH110XV60C 913900614ACX-048-230 TXV 48000 14.5 12 CH33-49 EL180UH090E60C 913900314ACX-048-230 TXV 48000 14.5 12 CH33-49 EL180UH110E60C 913899214ACX-048-230 TXV 48000 14.5 12 CH33-49 EL180UH110XE60C 913899314ACX-048-230 TXV 48000 14.5 12 CH33-49 EL195UH090XE48C 913900714ACX-048-230 TXV 48000 14.5 12 CH33-49 EL195UH110XE60C 913900914ACX-048-230 TXV 48000 14.5 12 CH33-49 EL296UH090XE48C 913900814ACX-048-230 TXV 48000 14.5 12 CH33-49 EL296UH090XV48C 913899914ACX-048-230 TXV 48000 14.25 12 CH33-49 EL296UH090XV60C 913900014ACX-048-230 TXV 48000 14.5 12 CH33-49 EL296UH110XE60C 913899814ACX-048-230 TXV 48000 14.5 12 CH33-49 EL296UH110XV48C 913900114ACX-048-230 TXV 48000 14.25 12 CH33-49 EL296UH110XV60C 913900214ACX-048-230 TXV 48000 14.5 12 CH33-49 SL280UH090V60C 913899414ACX-048-230 TXV 48000 14.5 12 CH33-49 SL280UH090XV60C 913899514ACX-048-230 TXV 48000 14.5 12 CH33-49 SL280UH110V60C 913899614ACX-048-230 TXV 48000 14.5 12 CH33-49 SL280UH110XV60C 913899714ACX-048-230 TXV 48000 14.5 12 CH33-49 SLP98UH090XV48C 913898614ACX-048-230 TXV 48000 14.25 12 CH33-49 SLP98UH090XV60C 913898714ACX-048-230 TXV 48000 14.25 12 CH33-49 SLP98UH110XV60C 913898814ACX-048-230 TXV 48000 14 11.7 CH33-49 913860814ACX-048-230 TXV 48000 14.5 12 CH33-50/60C EL180UH090E60C 913898514ACX-048-230 TXV 48000 14.25 12 CH33-50/60C EL180UH110E60C 913897414ACX-048-230 TXV 48000 14.25 12 CH33-50/60C EL180UH110XE60C 913897514ACX-048-230 TXV 48000 14.5 12 CH33-50/60C EL195UH090XE48C 913898914ACX-048-230 TXV 48000 14.5 12 CH33-50/60C EL195UH110XE60C 913899114ACX-048-230 TXV 48000 14.5 12 CH33-50/60C EL296UH090XE48C 913899014ACX-048-230 TXV 48000 14.25 12 CH33-50/60C EL296UH090XV48C 913898114ACX-048-230 TXV 48000 14.25 12 CH33-50/60C EL296UH090XV60C 913898214ACX-048-230 TXV 48000 14.5 12 CH33-50/60C EL296UH110XE60C 913898014ACX-048-230 TXV 48000 14.5 12 CH33-50/60C EL296UH110XV48C 913898314ACX-048-230 TXV 48000 14.25 12 CH33-50/60C EL296UH110XV60C 913898414ACX-048-230 TXV 48000 14.5 12 CH33-50/60C SL280UH090V60C 913897614ACX-048-230 TXV 48000 14.5 12 CH33-50/60C SL280UH090XV60C 913897714ACX-048-230 TXV 48000 14.5 12 CH33-50/60C SL280UH110V60C 913897814ACX-048-230 TXV 48000 14.5 12 CH33-50/60C SL280UH110XV60C 913897914ACX-048-230 TXV 48000 14.25 12 CH33-50/60C SLP98UH090XV48C 913896814ACX-048-230 TXV 48000 14.25 12 CH33-50/60C SLP98UH090XV60C 913896914ACX-048-230 TXV 48000 14.25 12 CH33-50/60C SLP98UH110XV60C 913897014ACX-048-230 TXV 48000 14 11.7 CH33-50/60C 913861714ACX-048-230 TXV 48000 15 12.5 CH33-60D EL180UH135E60D 913896214ACX-048-230 TXV 48000 14.25 12 CH33-60D EL195UH135XE60D 9138971NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 23

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-048-230 TXV 48000 14.25 12 CH33-60D EL296UH135XE60D 913897214ACX-048-230 TXV 48000 14.5 12 CH33-60D EL296UH135XV60D 913897314ACX-048-230 TXV 48000 14.5 12 CH33-60D SL280UH135V60D 913896314ACX-048-230 TXV 48000 14.5 12 CH33-60D SLP98UH135XV60D 913896414ACX-048-230 TXV 48000 15 12.5 CH33-62D EL180UH135E60D 913895614ACX-048-230 TXV 48000 14.5 12 CH33-62D EL195UH135XE60D 913896514ACX-048-230 TXV 48000 14.5 12 CH33-62D EL296UH135XE60D 913896614ACX-048-230 TXV 48000 14.5 12 CH33-62D EL296UH135XV60D 913896714ACX-048-230 TXV 48000 15 12.5 CH33-62D SL280UH135V60D 913895714ACX-048-230 TXV 48000 14.5 12 CH33-62D SLP98UH135XV60D 913895814ACX-048-230 TXV 48000 14 11.7 CH33-62D 913861814ACX-048-230 TXV 48000 14.5 12 CH35-42B EL180UH090E48B 913895914ACX-048-230 TXV 48000 14.5 12 CH35-42B EL180UH090XE48B 913896014ACX-048-230 TXV 48000 14.5 12 CH35-42C EL180UH090E60C 913894514ACX-048-230 TXV 48000 14.25 12 CH35-42C EL180UH110E60C 913894614ACX-048-230 TXV 48000 14.25 12 CH35-42C EL180UH110XE60C 913894714ACX-048-230 TXV 48000 14.25 12 CH35-42C EL195UH090XE48C 913896114ACX-048-230 TXV 48000 14.5 12 CH35-42C EL195UH110XE60C 913895114ACX-048-230 TXV 48000 14.25 12 CH35-42C EL296UH090XE48C 913895014ACX-048-230 TXV 48000 14.25 11.7 CH35-42C EL296UH090XV48C 913895314ACX-048-230 TXV 48000 14.25 12 CH35-42C EL296UH090XV60C 913895414ACX-048-230 TXV 48000 14.5 12 CH35-42C EL296UH110XE60C 913895214ACX-048-230 TXV 48000 14.25 12 CH35-42C EL296UH110XV48C 913895514ACX-048-230 TXV 48000 14.25 12 CH35-42C EL296UH110XV60C 913894414ACX-048-230 TXV 48000 14.5 12 CH35-42C SL280UH090V60C 913894814ACX-048-230 TXV 48000 14.5 12 CH35-42C SL280UH090XV60C 913894914ACX-048-230 TXV 48000 14.5 12 CH35-42C SL280UH110V60C 913893814ACX-048-230 TXV 48000 14.5 12 CH35-42C SL280UH110XV60C 913893914ACX-048-230 TXV 48000 14.25 11.7 CH35-42C SLP98UH090XV48C 913894014ACX-048-230 TXV 48000 14.25 12 CH35-42C SLP98UH090XV60C 913894114ACX-048-230 TXV 48000 14.25 12 CH35-42C SLP98UH110XV60C 913894214ACX-048-230 TXV 47500 14.25 11.7 CH35-48B EL180UH090E48B 913894314ACX-048-230 TXV 47500 14.25 11.7 CH35-48B EL180UH090XE48B 913893214ACX-048-230 TXV 48000 14.5 12 CH35-48C EL180UH090E60C 913892914ACX-048-230 TXV 48000 14.25 11.7 CH35-48C EL180UH110E60C 913893014ACX-048-230 TXV 48000 14.25 11.7 CH35-48C EL180UH110XE60C 913893114ACX-048-230 TXV 48000 14 12 CH35-48C EL195UH090XE48C 913893314ACX-048-230 TXV 48000 14 12 CH35-48C EL195UH110XE60C 913893514ACX-048-230 TXV 48000 14 12 CH35-48C EL296UH090XE48C 913893414ACX-048-230 TXV 48000 14.25 12 CH35-48C EL296UH090XV48C 913893714ACX-048-230 TXV 48000 14.25 11.7 CH35-48C EL296UH090XV60C 913892614ACX-048-230 TXV 48000 14 12 CH35-48C EL296UH110XE60C 913893614ACX-048-230 TXV 48000 14.25 12 CH35-48C EL296UH110XV48C 913892714ACX-048-230 TXV 48000 14.25 12 CH35-48C EL296UH110XV60C 913892814ACX-048-230 TXV 48000 14.5 12 CH35-48C SL280UH090V60C 913892014ACX-048-230 TXV 48000 14.5 12 CH35-48C SL280UH090XV60C 913892114ACX-048-230 TXV 48000 14.5 12 CH35-48C SL280UH110V60C 913892214ACX-048-230 TXV 48000 14.5 12 CH35-48C SL280UH110XV60C 913892314ACX-048-230 TXV 48000 14.25 12 CH35-48C SLP98UH090XV48C 9138924NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 24

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-048-230 TXV 48000 14.25 11.7 CH35-48C SLP98UH090XV60C 913892514ACX-048-230 TXV 48000 14.25 12 CH35-48C SLP98UH110XV60C 913891414ACX-048-230 TXV 48000 14.5 12 CH35-51C EL180UH090E60C 913891114ACX-048-230 TXV 48000 14.5 12 CH35-51C EL180UH110E60C 913891214ACX-048-230 TXV 48000 14.5 12 CH35-51C EL180UH110XE60C 913891314ACX-048-230 TXV 48000 14.5 12 CH35-51C EL195UH090XE48C 913891514ACX-048-230 TXV 48000 14.5 12 CH35-51C EL195UH110XE60C 913891714ACX-048-230 TXV 48000 14.5 12 CH35-51C EL296UH090XE48C 913891614ACX-048-230 TXV 48000 14.5 12 CH35-51C EL296UH090XV48C 913891914ACX-048-230 TXV 48000 14.5 12 CH35-51C EL296UH090XV60C 913890814ACX-048-230 TXV 48000 14.5 12 CH35-51C EL296UH110XE60C 913891814ACX-048-230 TXV 48000 14.5 12 CH35-51C EL296UH110XV48C 913890914ACX-048-230 TXV 48000 14.5 12 CH35-51C EL296UH110XV60C 913891014ACX-048-230 TXV 48000 14.5 12 CH35-51C SL280UH090V60C 913890214ACX-048-230 TXV 48000 14.5 12 CH35-51C SL280UH090XV60C 913890314ACX-048-230 TXV 48000 14.5 12 CH35-51C SL280UH110V60C 913890414ACX-048-230 TXV 48000 14.5 12 CH35-51C SL280UH110XV60C 913890514ACX-048-230 TXV 48000 14.5 12 CH35-51C SLP98UH090XV48C 913890614ACX-048-230 TXV 48000 14.5 12 CH35-51C SLP98UH090XV60C 913890714ACX-048-230 TXV 48000 14.5 12 CH35-51C SLP98UH110XV60C 913889614ACX-048-230 TXV 48000 14 11.7 CH35-51C 913861914ACX-048-230 TXV 48000 15 12.5 CH35-60D EL180UH135E60D 913890014ACX-048-230 TXV 48000 14.5 12 CH35-60D EL195UH135XE60D 913889714ACX-048-230 TXV 48000 14.5 12 CH35-60D EL296UH135XE60D 913889814ACX-048-230 TXV 48000 14.5 12 CH35-60D EL296UH135XV60D 913889914ACX-048-230 TXV 48000 15 12.5 CH35-60D SL280UH135V60D 913890114ACX-048-230 TXV 48000 14.5 12 CH35-60D SLP98UH135XV60D 913889014ACX-048-230 TXV 48000 14 11.7 CH35-60D 913862014ACX-048-230 TXV 46500 14.25 11.7 CR33-48 EL180DF110E60C 913889314ACX-048-230 TXV 46500 14 11.7 CR33-48 EL195DF110XE60C 913889114ACX-048-230 TXV 46500 14 11.7 CR33-48 EL296DF110XE60C 913889214ACX-048-230 TXV 46500 14.25 11.7 CR33-48 SL280DF090V60C 913889414ACX-048-230 TXV 46500 14.25 11.7 CR33-48 SL280DF110V60C 913889514ACX-048-230 TXV 47500 14.25 12 CR33-50/60 EL180DF110E60C 913888814ACX-048-230 TXV 47000 14.25 12 CR33-50/60 EL195DF110XE60C 913888414ACX-048-230 TXV 47000 14 11.7 CR33-50/60 EL296DF090XV60C 913888614ACX-048-230 TXV 47000 14.25 12 CR33-50/60 EL296DF110XE60C 913888514ACX-048-230 TXV 47000 14 11.7 CR33-50/60 EL296DF110XV60C 913888714ACX-048-230 TXV 47000 14.25 12 CR33-50/60 SL280DF090V60C 913888914ACX-048-230 TXV 47000 14.5 12 CR33-50/60 SL280DF110V60C 913887814ACX-048-230 TXV 47000 14 11.7 CR33-50/60 SLP98DF090XV48C 913887914ACX-048-230 TXV 47000 14 11.7 CR33-50/60 SLP98DF090XV60C 913888014ACX-048-230 TXV 47000 14 11.7 CR33-50/60 SLP98DF110XV60C 913888114ACX-048-230 TXV 48000 14.25 12 CX35-48B EL180UH090E48B 913870814ACX-048-230 TXV 48000 14.25 12 CX35-48B EL180UH090XE48B 913870914ACX-048-230 TXV 48000 14.5 12 CX35-48C EL180UH090E60C 913868814ACX-048-230 TXV 47500 14.5 12 CX35-48C EL180UH110E60C 913870114ACX-048-230 TXV 47500 14.5 12 CX35-48C EL180UH110XE60C 913870214ACX-048-230 TXV 48000 14.5 12 CX35-48C EL195UH090XE48C 9138689NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 25

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-048-230 TXV 48000 14.5 12 CX35-48C EL195UH110XE60C 913869114ACX-048-230 TXV 48000 14.5 12 CX35-48C EL296UH090XE48C 913869014ACX-048-230 TXV 48000 14 12 CX35-48C EL296UH090XV48C 913869614ACX-048-230 TXV 48000 14 12 CX35-48C EL296UH090XV60C 913869714ACX-048-230 TXV 48000 14.5 12 CX35-48C EL296UH110XE60C 913869514ACX-048-230 TXV 48000 14.5 12 CX35-48C EL296UH110XV48C 913868614ACX-048-230 TXV 48000 14 12 CX35-48C EL296UH110XV60C 913868714ACX-048-230 TXV 48000 14.5 12 CX35-48C SL280UH090V60C 913870314ACX-048-230 TXV 48000 14.5 12 CX35-48C SL280UH090XV60C 913869214ACX-048-230 TXV 48000 14.5 12 CX35-48C SL280UH110V60C 913869314ACX-048-230 TXV 48000 14.5 12 CX35-48C SL280UH110XV60C 913869414ACX-048-230 TXV 48000 14 12 CX35-48C SLP98UH090XV48C 913869814ACX-048-230 TXV 48000 14 12 CX35-48C SLP98UH090XV60C 913869914ACX-048-230 TXV 48000 14 12 CX35-48C SLP98UH110XV60C 913870014ACX-048-230 TXV 48000 15 12.5 CX35-49C EL180UH090E60C 913867814ACX-048-230 TXV 48000 14 12 CX35-49C EL180UH110E60C 913867914ACX-048-230 TXV 48000 14 12 CX35-49C EL180UH110XE60C 913866814ACX-048-230 TXV 48000 14.5 12 CX35-49C EL195UH090XE48C 913866914ACX-048-230 TXV 48000 14.5 12 CX35-49C EL195UH110XE60C 913867114ACX-048-230 TXV 48000 14.5 12 CX35-49C EL296UH090XE48C 913867014ACX-048-230 TXV 48000 14.5 12 CX35-49C EL296UH090XV48C 913867314ACX-048-230 TXV 48000 14.5 12 CX35-49C EL296UH090XV60C 913867514ACX-048-230 TXV 48000 14.5 12 CX35-49C EL296UH110XE60C 913867214ACX-048-230 TXV 48000 14.5 12 CX35-49C EL296UH110XV48C 913867614ACX-048-230 TXV 48000 14.5 12 CX35-49C EL296UH110XV60C 913867714ACX-048-230 TXV 48000 15 12.5 CX35-49C SL280UH090V60C 913868114ACX-048-230 TXV 48000 15 12.5 CX35-49C SL280UH090XV60C 913868214ACX-048-230 TXV 48000 15 12.5 CX35-49C SL280UH110V60C 913868314ACX-048-230 TXV 48000 15 12.5 CX35-49C SL280UH110XV60C 913868414ACX-048-230 TXV 48000 14.5 12 CX35-49C SLP98UH090XV48C 913868514ACX-048-230 TXV 48000 14.5 12 CX35-49C SLP98UH090XV60C 913867414ACX-048-230 TXV 48000 14.5 12 CX35-49C SLP98UH110XV60C 913868014ACX-048-230 TXV 48000 14 11.7 CX35-49C 913861614ACX-048-230 TXV 47500 14.5 12 CX35-50/60C EL180UH090E60C 913866014ACX-048-230 TXV 48000 14 11.7 CX35-50/60C EL180UH110E60C 913866114ACX-048-230 TXV 48000 14 11.7 CX35-50/60C EL180UH110XE60C 913865014ACX-048-230 TXV 47500 14.25 12 CX35-50/60C EL195UH090XE48C 913865114ACX-048-230 TXV 47500 14.25 12 CX35-50/60C EL195UH110XE60C 913865314ACX-048-230 TXV 47500 14.25 12 CX35-50/60C EL296UH090XE48C 913865214ACX-048-230 TXV 47500 14 11.7 CX35-50/60C EL296UH090XV48C 913865514ACX-048-230 TXV 47500 14 11.7 CX35-50/60C EL296UH090XV60C 913865714ACX-048-230 TXV 47500 14.25 12 CX35-50/60C EL296UH110XE60C 913865414ACX-048-230 TXV 47500 14.25 11.7 CX35-50/60C EL296UH110XV48C 913865814ACX-048-230 TXV 47500 14 11.7 CX35-50/60C EL296UH110XV60C 913865914ACX-048-230 TXV 47500 14.25 12 CX35-50/60C SL280UH090V60C 913866314ACX-048-230 TXV 47500 14.25 12 CX35-50/60C SL280UH090XV60C 913866414ACX-048-230 TXV 47500 14.25 12 CX35-50/60C SL280UH110V60C 913866514ACX-048-230 TXV 47500 14.25 12 CX35-50/60C SL280UH110XV60C 913866614ACX-048-230 TXV 47500 14 11.7 CX35-50/60C SLP98UH090XV48C 9138667NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 26

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-048-230 TXV 47500 14 11.7 CX35-50/60C SLP98UH090XV60C 913865614ACX-048-230 TXV 47500 14 11.7 CX35-50/60C SLP98UH110XV60C 913866214ACX-048-230 TXV 48000 15.1 12.5 CX35-60C EL180UH090E60C 913941414ACX-048-230 TXV 48000 15 12.5 CX35-60C EL180UH110E60C 913864514ACX-048-230 TXV 48000 15 12.5 CX35-60C EL180UH110XE60C 913863514ACX-048-230 TXV 48000 14.5 12.5 CX35-60C EL195UH090XE48C 913863614ACX-048-230 TXV 48000 15 12.5 CX35-60C EL195UH110XE60C 913863814ACX-048-230 TXV 48000 14.5 12.5 CX35-60C EL296UH090XE48C 913863714ACX-048-230 TXV 48000 14.5 12 CX35-60C EL296UH090XV48C 913864014ACX-048-230 TXV 48000 14.5 12 CX35-60C EL296UH090XV60C 913864214ACX-048-230 TXV 48000 15 12.5 CX35-60C EL296UH110XE60C 913863914ACX-048-230 TXV 48000 15 12.5 CX35-60C EL296UH110XV48C 913864314ACX-048-230 TXV 48000 14.5 12.5 CX35-60C EL296UH110XV60C 913864414ACX-048-230 TXV 48000 15.1 12.5 CX35-60C SL280UH090V60C 913941514ACX-048-230 TXV 48000 15.1 12.5 CX35-60C SL280UH090XV60C 913941614ACX-048-230 TXV 48000 15 12.5 CX35-60C SL280UH110V60C 913864714ACX-048-230 TXV 48000 15 12.5 CX35-60C SL280UH110XV60C 913864814ACX-048-230 TXV 48000 14.5 12 CX35-60C SLP98UH090XV48C 913864914ACX-048-230 TXV 48000 14.5 12 CX35-60C SLP98UH090XV60C 913864114ACX-048-230 TXV 48000 14.5 12.5 CX35-60C SLP98UH110XV60C 913864614ACX-048-230 TXV 48000 14 11.7 CX35-60C 913860914ACX-048-230 TXV 48000 15 12.5 CX35-60D EL180UH135E60D 913863314ACX-048-230 TXV 48000 14.25 12 CX35-60D EL195UH135XE60D 913863014ACX-048-230 TXV 48000 14.25 12 CX35-60D EL296UH135XE60D 913863214ACX-048-230 TXV 48000 14.5 12 CX35-60D EL296UH135XV60D 913863114ACX-048-230 TXV 48000 15 12.5 CX35-60D SL280UH135V60D 913863414ACX-048-230 TXV 48000 14.5 12 CX35-60D SLP98UH135XV60D 913862914ACX-048-230 TXV 48000 14 11.7 CX35-60D 913861014ACX-048-230 TXV 48000 14.25 12 CX38-62C 1054705814ACX-059-230 TXV 56000 14 12.2 C35-48C EL180UH090E60C 1049044514ACX-059-230 TXV 56000 14 12.2 C35-48C EL180UH090E60C 913927814ACX-059-230 TXV 56000 14 12.2 C35-48C EL180UH110E60C 913927914ACX-059-230 TXV 56000 14 12.2 C35-48C EL180UH110E60C 1049044614ACX-059-230 TXV 56000 14.5 12.2 C35-48C EL195UH110XE60C 1049044714ACX-059-230 TXV 56000 14.5 12.2 C35-48C EL195UH110XE60C 913928014ACX-059-230 TXV 56000 14.5 12.2 C35-48C EL296UH110XE60C 913927014ACX-059-230 TXV 56000 14.5 12.2 C35-48C EL296UH110XE60C 1049043714ACX-059-230 TXV 56000 14.5 12 C35-48C EL296UH110XV60C 1049043614ACX-059-230 TXV 56000 14.5 12 C35-48C EL296UH110XV60C 913926914ACX-059-230 TXV 56000 14.5 12.2 C35-48C SL280UH090V60C 913927114ACX-059-230 TXV 56000 14.5 12.2 C35-48C SL280UH090V60C 1049043814ACX-059-230 TXV 56000 14.5 12.2 C35-48C SL280UH110V60C 913927214ACX-059-230 TXV 56000 14.5 12.2 C35-48C SL280UH110V60C 1049043914ACX-059-230 TXV 56000 14.5 12.2 C35-48C SL280UH110XV60C 1049044014ACX-059-230 TXV 56000 14.5 12.2 C35-48C SL280UH110XV60C 913927314ACX-059-230 TXV 56000 14 11.7 C35-48C SLP98UH090XV60C 913927414ACX-059-230 TXV 56000 14 11.7 C35-48C SLP98UH090XV60C 1049044114ACX-059-230 TXV 56000 14.2 11.7 C35-48C SLP98UH110XV60C 1049043014ACX-059-230 TXV 56000 14.2 11.7 C35-48C SLP98UH110XV60C 9139263NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 27

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-059-230 TXV 56000 14 11.7 C35-48C 913918314ACX-059-230 TXV 56000 14 11.7 C35-48C 1049035014ACX-059-230 TXV 56500 15 12.2 C35-49C EL180UH090E60C 913921314ACX-059-230 TXV 56500 15 12.2 C35-49C EL180UH090E60C 1049038014ACX-059-230 TXV 56500 15 12.2 C35-49C EL180UH110E60C 1049038114ACX-059-230 TXV 56500 15 12.2 C35-49C EL180UH110E60C 913921414ACX-059-230 TXV 56500 14.5 12.2 C35-49C EL195UH110XE60C 913920314ACX-059-230 TXV 56500 14.5 12.2 C35-49C EL195UH110XE60C 1049037014ACX-059-230 TXV 56500 14.5 12.2 C35-49C EL296UH110XE60C 913920514ACX-059-230 TXV 56500 14.5 12.2 C35-49C EL296UH110XE60C 1049037214ACX-059-230 TXV 56500 14.5 12 C35-49C EL296UH110XV60C 913920414ACX-059-230 TXV 56500 14.5 12 C35-49C EL296UH110XV60C 1049037114ACX-059-230 TXV 56500 15 12.2 C35-49C SL280UH090V60C 913920614ACX-059-230 TXV 56500 15 12.2 C35-49C SL280UH090V60C 1049037314ACX-059-230 TXV 56500 14.5 12.2 C35-49C SL280UH110V60C 913920714ACX-059-230 TXV 56500 14.5 12.2 C35-49C SL280UH110V60C 1049037414ACX-059-230 TXV 56500 14.5 12.2 C35-49C SL280UH110XV60C 1049037514ACX-059-230 TXV 56500 14.5 12.2 C35-49C SL280UH110XV60C 913920814ACX-059-230 TXV 57000 14.2 12.2 C35-49C SLP98UH090XV60C 913919714ACX-059-230 TXV 57000 14.2 12.2 C35-49C SLP98UH090XV60C 1049036414ACX-059-230 TXV 56500 14.5 12 C35-49C SLP98UH110XV60C 913919814ACX-059-230 TXV 56500 14.5 12 C35-49C SLP98UH110XV60C 1049036514ACX-059-230 TXV 57000 14.5 12 C35-49C 913917014ACX-059-230 TXV 57000 14.5 12 C35-49C 1049033714ACX-059-230 TXV 56500 14 11.7 C35-50/60C EL180UH090E60C 913926414ACX-059-230 TXV 56500 14 11.7 C35-50/60C EL180UH090E60C 1049043114ACX-059-230 TXV 56000 14 11.7 C35-50/60C EL180UH110E60C 913926514ACX-059-230 TXV 56000 14 11.7 C35-50/60C EL180UH110E60C 1049043214ACX-059-230 TXV 55500 14.2 11.7 C35-50/60C SL280UH090V60C 1049043314ACX-059-230 TXV 55500 14.2 11.7 C35-50/60C SL280UH090V60C 913926614ACX-059-230 TXV 55500 14.2 12 C35-50/60C SL280UH110V60C 913926714ACX-059-230 TXV 55500 14.2 12 C35-50/60C SL280UH110V60C 1049043414ACX-059-230 TXV 55500 14.2 12 C35-50/60C SL280UH110XV60C 913926814ACX-059-230 TXV 55500 14.2 12 C35-50/60C SL280UH110XV60C 1049043514ACX-059-230 TXV 55500 14.2 11.7 C35-50/60C SLP98UH110XV60C 1049042414ACX-059-230 TXV 55500 14.2 11.7 C35-50/60C SLP98UH110XV60C 913925714ACX-059-230 TXV 55500 14.2 11.7 C35-50/60C 1049033914ACX-059-230 TXV 55500 14.2 11.7 C35-50/60C 913917214ACX-059-230 TXV 58000 15.5 12.5 C35-60C EL180UH090E60C 1049042514ACX-059-230 TXV 58000 15.5 12.5 C35-60C EL180UH090E60C 913925814ACX-059-230 TXV 57500 15.1 12.5 C35-60C EL180UH110XE60C 913925914ACX-059-230 TXV 57500 15.1 12.5 C35-60C EL180UH110XE60C 1049042614ACX-059-230 TXV 57000 14.5 12.2 C35-60C EL195UH110XE60C 1049042714ACX-059-230 TXV 57000 14.5 12.2 C35-60C EL195UH110XE60C 913926014ACX-059-230 TXV 57000 14.5 12.2 C35-60C EL296UH110XE60C 913926214ACX-059-230 TXV 57000 14.5 12.2 C35-60C EL296UH110XE60C 1049042914ACX-059-230 TXV 58000 14.5 12.2 C35-60C EL296UH110XV60C 913926114ACX-059-230 TXV 58000 14.5 12.2 C35-60C EL296UH110XV60C 1049042814ACX-059-230 TXV 58000 15.1 12.5 C35-60C SL280UH090V60C 10490418NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 28

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-059-230 TXV 58000 15.1 12.5 C35-60C SL280UH090V60C 913925114ACX-059-230 TXV 58000 14.5 12.2 C35-60C SL280UH110V60C 913925214ACX-059-230 TXV 58000 14.5 12.2 C35-60C SL280UH110V60C 1049041914ACX-059-230 TXV 58000 14.5 12.2 C35-60C SL280UH110XV60C 913925314ACX-059-230 TXV 58000 14.5 12.2 C35-60C SL280UH110XV60C 1049042014ACX-059-230 TXV 58000 14.5 12.2 C35-60C SLP98UH090XV60C 1049042114ACX-059-230 TXV 58000 14.5 12.2 C35-60C SLP98UH090XV60C 913925414ACX-059-230 TXV 57500 15 12.2 C35-60C SLP98UH110XV60C 1049042214ACX-059-230 TXV 57500 15 12.2 C35-60C SLP98UH110XV60C 913925514ACX-059-230 TXV 57500 14.5 12.2 C35-60C 913917314ACX-059-230 TXV 57500 14.5 12.2 C35-60C 1049034014ACX-059-230 TXV 56500 15.5 12.5 C35-60D EL180UH135E60D 1049042314ACX-059-230 TXV 56500 15.5 12.5 C35-60D EL180UH135E60D 913925614ACX-059-230 TXV 57500 14.5 12.2 C35-60D EL195UH135XE60D 1049041214ACX-059-230 TXV 57500 14.5 12.2 C35-60D EL195UH135XE60D 913924514ACX-059-230 TXV 57500 14.5 12.2 C35-60D EL296UH135XE60D 913924714ACX-059-230 TXV 57500 14.5 12.2 C35-60D EL296UH135XE60D 1049041414ACX-059-230 TXV 57500 15 12.2 C35-60D EL296UH135XV60D 1049041314ACX-059-230 TXV 57500 15 12.2 C35-60D EL296UH135XV60D 913924614ACX-059-230 TXV 57000 15.5 12.5 C35-60D SL280UH135V60D 1049041514ACX-059-230 TXV 57000 15.5 12.5 C35-60D SL280UH135V60D 913924814ACX-059-230 TXV 57000 14.5 11.7 C35-60D 1049034114ACX-059-230 TXV 57000 14.5 11.7 C35-60D 913917414ACX-059-230 TXV 56000 15 12 CBA27UHE-060 1025938514ACX-059-230 TXV 56000 15 12 CBA27UHE-060 1049058014ACX-059-230 TXV 56500 14.5 12 CBX25UH-060 913932814ACX-059-230 TXV 56500 14.5 12 CBX25UH-060 1049049514ACX-059-230 TXV 57000 15 12.5 CBX25UHV-060 1049046514ACX-059-230 TXV 57000 15 12.5 CBX25UHV-060 913929814ACX-059-230 TXV 56500 15 12.2 CBX27UH-060 1049057514ACX-059-230 TXV 56500 15 12.2 CBX27UH-060 913940814ACX-059-230 TXV 56500 14.5 12.2 CBX32M-060 913940914ACX-059-230 TXV 56500 14.5 12.2 CBX32M-060 1049057614ACX-059-230 TXV 55500 14.7 12 CBX32MV-048 913941014ACX-059-230 TXV 55500 14.7 12 CBX32MV-048 1049057714ACX-059-230 TXV 56500 14.7 12.2 CBX32MV-060 913941114ACX-059-230 TXV 56500 14.7 12.2 CBX32MV-060 1049057814ACX-059-230 TXV 56000 14.7 12 CBX32MV-068 1049035714ACX-059-230 TXV 56000 14.7 12 CBX32MV-068 913919014ACX-059-230 TXV 56000 15 12.2 CBX40UHV-048 913919114ACX-059-230 TXV 56000 15 12.2 CBX40UHV-048 1049035814ACX-059-230 TXV 56500 14.7 12.2 CBX40UHV-060 913919214ACX-059-230 TXV 56500 14.7 12.2 CBX40UHV-060 1049035914ACX-059-230 TXV 57500 15.2 12.5 CH23-68 EL180UH135E60D 913929714ACX-059-230 TXV 57500 15.2 12.5 CH23-68 EL180UH135E60D 1049046414ACX-059-230 TXV 57500 14.7 12.2 CH23-68 EL195UH135XE60D 913939914ACX-059-230 TXV 57500 14.7 12.2 CH23-68 EL195UH135XE60D 1049056614ACX-059-230 TXV 57500 14.7 12.2 CH23-68 EL296UH135XE60D 913933314ACX-059-230 TXV 57500 14.7 12.2 CH23-68 EL296UH135XE60D 10490500NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 29

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-059-230 TXV 57000 14.5 12.5 CH23-68 1049033114ACX-059-230 TXV 57000 14.5 12.5 CH23-68 913916414ACX-059-230 TXV 57000 15 12.5 CH33-49 EL180UH090E60C 913930614ACX-059-230 TXV 57000 15 12.5 CH33-49 EL180UH090E60C 1049047314ACX-059-230 TXV 56500 15 12.2 CH33-49 EL180UH110E60C 1049047514ACX-059-230 TXV 56500 15 12.2 CH33-49 EL180UH110E60C 913930814ACX-059-230 TXV 56500 15 12.2 CH33-49 EL180UH110XE60C 1049047714ACX-059-230 TXV 56500 15 12.2 CH33-49 EL180UH110XE60C 913931014ACX-059-230 TXV 56500 15 12.2 CH33-49 EL195UH110XE60C 913939514ACX-059-230 TXV 56500 15 12.2 CH33-49 EL195UH110XE60C 1049056214ACX-059-230 TXV 56500 15 12.2 CH33-49 EL296UH110XE60C 913932914ACX-059-230 TXV 56500 15 12.2 CH33-49 EL296UH110XE60C 1049049614ACX-059-230 TXV 57000 15 12.2 CH33-49 SL280UH090V60C 1049036014ACX-059-230 TXV 57000 15 12.2 CH33-49 SL280UH090V60C 913919314ACX-059-230 TXV 57000 14.7 12 CH33-49 SL280UH110V60C 1049036114ACX-059-230 TXV 57000 14.7 12 CH33-49 SL280UH110V60C 913919414ACX-059-230 TXV 57000 14.7 12 CH33-49 SL280UH110XV60C 913940114ACX-059-230 TXV 57000 14.7 12 CH33-49 SL280UH110XV60C 1049056814ACX-059-230 TXV 57000 14.5 12 CH33-49 SLP98UH090XV60C 1049052514ACX-059-230 TXV 57000 14.5 12 CH33-49 SLP98UH090XV60C 913935814ACX-059-230 TXV 57500 14.2 11.7 CH33-50/60C EL180UH090E60C 913930714ACX-059-230 TXV 57500 14.2 11.7 CH33-50/60C EL180UH090E60C 1049047414ACX-059-230 TXV 57500 14.2 12 CH33-50/60C EL180UH110E60C 1049048514ACX-059-230 TXV 57500 14.2 12 CH33-50/60C EL180UH110E60C 913931814ACX-059-230 TXV 57500 14.2 12 CH33-50/60C EL180UH110XE60C 913930214ACX-059-230 TXV 57500 14.2 12 CH33-50/60C EL180UH110XE60C 1049046914ACX-059-230 TXV 57000 14.2 11.7 CH33-50/60C EL195UH110XE60C 1049056314ACX-059-230 TXV 57000 14.2 11.7 CH33-50/60C EL195UH110XE60C 913939614ACX-059-230 TXV 57000 14.2 11.7 CH33-50/60C EL296UH110XE60C 913933014ACX-059-230 TXV 57000 14.2 11.7 CH33-50/60C EL296UH110XE60C 1049049714ACX-059-230 TXV 56500 14.5 12 CH33-50/60C SL280UH090V60C 1049056914ACX-059-230 TXV 56500 14.5 12 CH33-50/60C SL280UH090V60C 913940214ACX-059-230 TXV 56000 14.5 12 CH33-50/60C SL280UH110V60C 1049057014ACX-059-230 TXV 56000 14.5 12 CH33-50/60C SL280UH110V60C 913940314ACX-059-230 TXV 56000 14.5 12 CH33-50/60C SL280UH110XV60C 1049054414ACX-059-230 TXV 56000 14.5 12 CH33-50/60C SL280UH110XV60C 913937714ACX-059-230 TXV 56500 15 12.2 CH33-60D EL180UH135E60D 913930314ACX-059-230 TXV 56500 15 12.2 CH33-60D EL180UH135E60D 1049047014ACX-059-230 TXV 56500 14.5 12 CH33-60D EL195UH135XE60D 1049054314ACX-059-230 TXV 56500 14.5 12 CH33-60D EL195UH135XE60D 913937614ACX-059-230 TXV 56500 14.5 12 CH33-60D EL296UH135XE60D 1049050114ACX-059-230 TXV 56500 14.5 12 CH33-60D EL296UH135XE60D 913933414ACX-059-230 TXV 56500 14.7 12.2 CH33-60D EL296UH135XV60D 913934614ACX-059-230 TXV 56500 14.7 12.2 CH33-60D EL296UH135XV60D 1049051314ACX-059-230 TXV 56500 14.7 12.2 CH33-60D SL280UH135V60D 913939314ACX-059-230 TXV 56500 14.7 12.2 CH33-60D SL280UH135V60D 1049056014ACX-059-230 TXV 56500 14.7 12.2 CH33-60D SLP98UH135XV60D 913936114ACX-059-230 TXV 56500 14.7 12.2 CH33-60D SLP98UH135XV60D 1049052814ACX-059-230 TXV 56000 14.5 11.7 CH33-60D 9139179NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 30

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-059-230 TXV 56000 14.5 11.7 CH33-60D 1049034614ACX-059-230 TXV 57000 15 12.2 CH33-62D EL180UH135E60D 1049047114ACX-059-230 TXV 57000 15 12.2 CH33-62D EL180UH135E60D 913930414ACX-059-230 TXV 57000 14.5 12 CH33-62D EL195UH135XE60D 1049053214ACX-059-230 TXV 57000 14.5 12 CH33-62D EL195UH135XE60D 913936514ACX-059-230 TXV 57000 14.5 12 CH33-62D EL296UH135XE60D 913932314ACX-059-230 TXV 57000 14.5 12 CH33-62D EL296UH135XE60D 1049049014ACX-059-230 TXV 57000 15 12.2 CH33-62D EL296UH135XV60D 1049050214ACX-059-230 TXV 57000 15 12.2 CH33-62D EL296UH135XV60D 913933514ACX-059-230 TXV 57000 14.7 12.2 CH33-62D SL280UH135V60D 913939414ACX-059-230 TXV 57000 14.7 12.2 CH33-62D SL280UH135V60D 1049056114ACX-059-230 TXV 56500 15 12.2 CH33-62D SLP98UH135XV60D 1049052914ACX-059-230 TXV 56500 15 12.2 CH33-62D SLP98UH135XV60D 913936214ACX-059-230 TXV 56500 14.5 12 CH33-62D 1049034714ACX-059-230 TXV 56500 14.5 12 CH33-62D 913918014ACX-059-230 TXV 58000 14.5 12 CH35-51C EL180UH090E60C 1049045814ACX-059-230 TXV 58000 14.5 12 CH35-51C EL180UH090E60C 913929114ACX-059-230 TXV 58000 14.5 12 CH35-51C EL180UH110E60C 913929214ACX-059-230 TXV 58000 14.5 12 CH35-51C EL180UH110E60C 1049045914ACX-059-230 TXV 57500 14.25 11.7 CH35-51C EL195UH110XE60C 1049045614ACX-059-230 TXV 57500 14.25 11.7 CH35-51C EL195UH110XE60C 913928914ACX-059-230 TXV 57500 14.25 11.7 CH35-51C EL296UH110XE60C 1049045714ACX-059-230 TXV 57500 14.25 11.7 CH35-51C EL296UH110XE60C 913929014ACX-059-230 TXV 57500 14.5 12 CH35-51C SL280UH090V60C 913928114ACX-059-230 TXV 57500 14.5 12 CH35-51C SL280UH090V60C 1049044814ACX-059-230 TXV 56500 14.5 12 CH35-51C SL280UH110V60C 1049044914ACX-059-230 TXV 56500 14.5 12 CH35-51C SL280UH110V60C 913928214ACX-059-230 TXV 56500 14.5 12 CH35-51C SL280UH110XV60C 913928314ACX-059-230 TXV 56500 14.5 12 CH35-51C SL280UH110XV60C 1049045014ACX-059-230 TXV 57000 14.5 12 CH35-51C SLP98UH090XV60C 1049045514ACX-059-230 TXV 57000 14.5 12 CH35-51C SLP98UH090XV60C 913928814ACX-059-230 TXV 57000 14.5 12 CH35-51C SLP98UH110XV60C 1049045414ACX-059-230 TXV 57000 14.5 12 CH35-51C SLP98UH110XV60C 913928714ACX-059-230 TXV 57000 14.5 12 CH35-51C 1049034814ACX-059-230 TXV 57000 14.5 12 CH35-51C 913918114ACX-059-230 TXV 57000 15 12 CH35-60D EL180UH135E60D 913927514ACX-059-230 TXV 57000 15 12 CH35-60D EL180UH135E60D 1049044214ACX-059-230 TXV 57000 14.5 12 CH35-60D EL195UH135XE60D 913928414ACX-059-230 TXV 57000 14.5 12 CH35-60D EL195UH135XE60D 1049045114ACX-059-230 TXV 57000 14.5 12 CH35-60D EL296UH135XE60D 913928614ACX-059-230 TXV 57000 14.5 12 CH35-60D EL296UH135XE60D 1049045314ACX-059-230 TXV 57000 15 12 CH35-60D EL296UH135XV60D 1049045214ACX-059-230 TXV 57000 15 12 CH35-60D EL296UH135XV60D 913928514ACX-059-230 TXV 57000 15 12 CH35-60D SL280UH135V60D 913927614ACX-059-230 TXV 57000 15 12 CH35-60D SL280UH135V60D 1049044314ACX-059-230 TXV 57000 15 12 CH35-60D SLP98UH135XV60D 913927714ACX-059-230 TXV 57000 15 12 CH35-60D SLP98UH135XV60D 1049044414ACX-059-230 TXV 56500 14.5 12 CH35-60D 913918214ACX-059-230 TXV 56500 14.5 12 CH35-60D 10490349NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 31

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-059-230 TXV 56000 15 12.2 CR33-50/60 EL180DF110E60C 1049048414ACX-059-230 TXV 56000 15 12.2 CR33-50/60 EL180DF110E60C 913931714ACX-059-230 TXV 55500 14.5 12 CR33-50/60 EL195DF110XE60C 1049057114ACX-059-230 TXV 55500 14.5 12 CR33-50/60 EL195DF110XE60C 913940414ACX-059-230 TXV 55500 14.5 12 CR33-50/60 EL296DF110XE60C 913933814ACX-059-230 TXV 55500 14.5 12 CR33-50/60 EL296DF110XE60C 1049050514ACX-059-230 TXV 55500 14.7 12 CR33-50/60 SL280DF090V60C 913938314ACX-059-230 TXV 55500 14.7 12 CR33-50/60 SL280DF090V60C 1049055014ACX-059-230 TXV 56000 14.7 12.2 CR33-50/60 SL280DF110V60C 913938414ACX-059-230 TXV 56000 14.7 12.2 CR33-50/60 SL280DF110V60C 1049055114ACX-059-230 TXV 56500 14.2 11.7 CR33-50/60 SLP98DF090XV60C 913936314ACX-059-230 TXV 56500 14.2 11.7 CR33-50/60 SLP98DF090XV60C 1049053014ACX-059-230 TXV 55500 14.2 11.7 CR33-50/60 SLP98DF110XV60C 913936414ACX-059-230 TXV 55500 14.2 11.7 CR33-50/60 SLP98DF110XV60C 1049053114ACX-059-230 TXV 55500 14.2 11.7 CR33-50/60 913918414ACX-059-230 TXV 55500 14.2 11.7 CR33-50/60 1049035114ACX-059-230 TXV 55500 14.2 11.7 CR33-60 913916514ACX-059-230 TXV 55500 14.2 11.7 CR33-60 1049033214ACX-059-230 TXV 56000 14 12.2 CX35-48C EL180UH090E60C 1049041614ACX-059-230 TXV 56000 14 12.2 CX35-48C EL180UH090E60C 913924914ACX-059-230 TXV 56000 14 12.2 CX35-48C EL180UH110E60C 1049041714ACX-059-230 TXV 56000 14 12.2 CX35-48C EL180UH110E60C 913925014ACX-059-230 TXV 56000 14.5 12.2 CX35-48C EL195UH110XE60C 1049040614ACX-059-230 TXV 56000 14.5 12.2 CX35-48C EL195UH110XE60C 913923914ACX-059-230 TXV 56000 14.5 12.2 CX35-48C EL296UH110XE60C 913924114ACX-059-230 TXV 56000 14.5 12.2 CX35-48C EL296UH110XE60C 1049040814ACX-059-230 TXV 56000 14.5 12 CX35-48C EL296UH110XV60C 1049040714ACX-059-230 TXV 56000 14.5 12 CX35-48C EL296UH110XV60C 913924014ACX-059-230 TXV 56000 14.5 12.2 CX35-48C SL280UH090V60C 1049040914ACX-059-230 TXV 56000 14.5 12.2 CX35-48C SL280UH090V60C 913924214ACX-059-230 TXV 56000 14.5 12 CX35-48C SL280UH110V60C 1049041014ACX-059-230 TXV 56000 14.5 12 CX35-48C SL280UH110V60C 913924314ACX-059-230 TXV 56000 14.5 12.2 CX35-48C SL280UH110XV60C 913924414ACX-059-230 TXV 56000 14.5 12.2 CX35-48C SL280UH110XV60C 1049041114ACX-059-230 TXV 56000 14 11.7 CX35-48C SLP98UH090XV60C 1049040014ACX-059-230 TXV 56000 14 11.7 CX35-48C SLP98UH090XV60C 913923314ACX-059-230 TXV 56000 14.2 12.2 CX35-48C SLP98UH110XV60C 913923414ACX-059-230 TXV 56000 14.2 12.2 CX35-48C SLP98UH110XV60C 1049040114ACX-059-230 TXV 56000 14.2 11.7 CX35-48C 913917514ACX-059-230 TXV 56000 14.2 11.7 CX35-48C 1049034214ACX-059-230 TXV 56500 15 12.2 CX35-49C EL180UH090E60C 913923514ACX-059-230 TXV 56500 15 12.2 CX35-49C EL180UH090E60C 1049040214ACX-059-230 TXV 56500 15 12.2 CX35-49C EL180UH110E60C 1049040314ACX-059-230 TXV 56500 15 12.2 CX35-49C EL180UH110E60C 913923614ACX-059-230 TXV 56500 14.5 12.2 CX35-49C EL195UH110XE60C 913923714ACX-059-230 TXV 56500 14.5 12.2 CX35-49C EL195UH110XE60C 1049040414ACX-059-230 TXV 56500 14.5 12.2 CX35-49C EL296UH110XE60C 1049039414ACX-059-230 TXV 56500 14.5 12.2 CX35-49C EL296UH110XE60C 913922714ACX-059-230 TXV 56500 14.5 12 CX35-49C EL296UH110XV60C 10490405NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 32

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-059-230 TXV 56500 14.5 12 CX35-49C EL296UH110XV60C 913923814ACX-059-230 TXV 56500 15 12.2 CX35-49C SL280UH090V60C 1049039514ACX-059-230 TXV 56500 15 12.2 CX35-49C SL280UH090V60C 913922814ACX-059-230 TXV 56500 14.5 12.2 CX35-49C SL280UH110V60C 1049039614ACX-059-230 TXV 56500 14.5 12.2 CX35-49C SL280UH110V60C 913922914ACX-059-230 TXV 56500 14.5 12.2 CX35-49C SL280UH110XV60C 913923014ACX-059-230 TXV 56500 14.5 12.2 CX35-49C SL280UH110XV60C 1049039714ACX-059-230 TXV 57000 14.2 12.2 CX35-49C SLP98UH090XV60C 913923114ACX-059-230 TXV 57000 14.2 12.2 CX35-49C SLP98UH090XV60C 1049039814ACX-059-230 TXV 56500 14.5 12 CX35-49C SLP98UH110XV60C 913923214ACX-059-230 TXV 56500 14.5 12 CX35-49C SLP98UH110XV60C 1049039914ACX-059-230 TXV 57000 14.5 12 CX35-49C 1049034314ACX-059-230 TXV 57000 14.5 12 CX35-49C 913917614ACX-059-230 TXV 56500 14 11.7 CX35-50/60C EL180UH090E60C 913922114ACX-059-230 TXV 56500 14 11.7 CX35-50/60C EL180UH090E60C 1049038814ACX-059-230 TXV 56000 14 11.7 CX35-50/60C EL180UH110E60C 1049038914ACX-059-230 TXV 56000 14 11.7 CX35-50/60C EL180UH110E60C 913922214ACX-059-230 TXV 55500 14.2 11.7 CX35-50/60C SL280UH090V60C 913922314ACX-059-230 TXV 55500 14.2 11.7 CX35-50/60C SL280UH090V60C 1049039014ACX-059-230 TXV 55500 14.2 12 CX35-50/60C SL280UH110V60C 1049039114ACX-059-230 TXV 55500 14.2 12 CX35-50/60C SL280UH110V60C 913922414ACX-059-230 TXV 55500 14.2 12 CX35-50/60C SL280UH110XV60C 1049039214ACX-059-230 TXV 55500 14.2 12 CX35-50/60C SL280UH110XV60C 913922514ACX-059-230 TXV 55500 14.2 11.7 CX35-50/60C SLP98UH110XV60C 1049039314ACX-059-230 TXV 55500 14.2 11.7 CX35-50/60C SLP98UH110XV60C 913922614ACX-059-230 TXV 55500 14.2 11.7 CX35-50/60C 1049034414ACX-059-230 TXV 55500 14.2 11.7 CX35-50/60C 913917714ACX-059-230 TXV 58000 15.5 12.5 CX35-60C EL180UH090E60C 913921514ACX-059-230 TXV 58000 15.5 12.5 CX35-60C EL180UH090E60C 1049038214ACX-059-230 TXV 57500 15.1 12.5 CX35-60C EL180UH110E60C 1049038314ACX-059-230 TXV 57500 15.1 12.5 CX35-60C EL180UH110E60C 913921614ACX-059-230 TXV 57000 14.5 12.2 CX35-60C EL195UH110XE60C 913921714ACX-059-230 TXV 57000 14.5 12.2 CX35-60C EL195UH110XE60C 1049038414ACX-059-230 TXV 57000 14.5 12.2 CX35-60C EL296UH110XE60C 913921914ACX-059-230 TXV 57000 14.5 12.2 CX35-60C EL296UH110XE60C 1049038614ACX-059-230 TXV 58000 14.5 12.2 CX35-60C EL296UH110XV60C 913921814ACX-059-230 TXV 58000 14.5 12.2 CX35-60C EL296UH110XV60C 1049038514ACX-059-230 TXV 58000 15.1 12.5 CX35-60C SL280UH090V60C 1049038714ACX-059-230 TXV 58000 15.1 12.5 CX35-60C SL280UH090V60C 913922014ACX-059-230 TXV 58000 14.5 12.2 CX35-60C SL280UH110V60C 913920914ACX-059-230 TXV 58000 14.5 12.2 CX35-60C SL280UH110V60C 1049037614ACX-059-230 TXV 58000 14.5 12.2 CX35-60C SL280UH110XV60C 913921014ACX-059-230 TXV 58000 14.5 12.2 CX35-60C SL280UH110XV60C 1049037714ACX-059-230 TXV 58000 14.5 12.2 CX35-60C SLP98UH090XV60C 1049037814ACX-059-230 TXV 58000 14.5 12.2 CX35-60C SLP98UH090XV60C 913921114ACX-059-230 TXV 57500 15 12.2 CX35-60C SLP98UH110XV60C 913921214ACX-059-230 TXV 57500 15 12.2 CX35-60C SLP98UH110XV60C 1049037914ACX-059-230 TXV 57500 14.5 12.2 CX35-60C 1049033614ACX-059-230 TXV 57500 14.5 12.2 CX35-60C 9139169NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 33

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-059-230 TXV 56500 15.5 12.5 CX35-60D EL180UH135E60D 913919914ACX-059-230 TXV 56500 15.5 12.5 CX35-60D EL180UH135E60D 1049036614ACX-059-230 TXV 57500 14.5 12.2 CX35-60D EL195UH135XE60D 913920014ACX-059-230 TXV 57500 14.5 12.2 CX35-60D EL195UH135XE60D 1049036714ACX-059-230 TXV 57500 14.5 12.2 CX35-60D EL296UH135XE60D 1049036914ACX-059-230 TXV 57500 14.5 12.2 CX35-60D EL296UH135XE60D 913920214ACX-059-230 TXV 57500 15 12.2 CX35-60D EL296UH135XV60D 1049036814ACX-059-230 TXV 57500 15 12.2 CX35-60D EL296UH135XV60D 913920114ACX-059-230 TXV 57000 15.5 12.5 CX35-60D SL280UH135V60D 913919614ACX-059-230 TXV 57000 15.5 12.5 CX35-60D SL280UH135V60D 1049036314ACX-059-230 TXV 57000 14.5 11.7 CX35-60D 913917114ACX-059-230 TXV 57000 14.5 11.7 CX35-60D 1049033814ACX-059-230 TXV 57500 14.7 12.2 CX38-62C 1054723214ACX-059-230 TXV 57500 14.7 12.2 CX38-62C 1054714514ACX-060-230 TXV 58000 14.5 12 C35-49C EL180UH090E60C 826731514ACX-060-230 TXV 57500 14.2 12 C35-49C EL180UH110E60C 826731714ACX-060-230 TXV 57500 14.2 12 C35-49C EL180UH110XE60C 826731414ACX-060-230 TXV 57500 14.2 12 C35-49C EL195UH110XE60C 826730814ACX-060-230 TXV 57000 14.2 11.7 C35-49C EL296UH090XV60C 826731814ACX-060-230 TXV 57500 14.2 12 C35-49C EL296UH110XE60C 826730914ACX-060-230 TXV 57000 14.2 12 C35-49C EL296UH110XV60C 826731614ACX-060-230 TXV 58000 14.2 12 C35-49C SL280UH090V60C 826731214ACX-060-230 TXV 58000 14.2 12 C35-49C SL280UH090XV60C 826731914ACX-060-230 TXV 57500 14.2 12 C35-49C SL280UH110V60C 826731314ACX-060-230 TXV 57500 14.2 12 C35-49C SL280UH110XV60C 826732014ACX-060-230 TXV 57000 14.2 11.7 C35-49C SLP98UH090XV60C 826731014ACX-060-230 TXV 57000 14.2 12 C35-49C SLP98UH110XV60C 826731114ACX-060-230 TXV 58000 14 11.7 C35-49C 826730714ACX-060-230 TXV 56500 14.2 11.7 C35-50/60C EL180UH090E60C 826732314ACX-060-230 TXV 56500 14 11.7 C35-50/60C EL180UH110E60C 826732214ACX-060-230 TXV 56500 14 11.7 C35-50/60C EL180UH110XE60C 826732114ACX-060-230 TXV 56500 14 11.7 C35-50/60C EL195UH110XE60C 826732414ACX-060-230 TXV 56500 14 11.7 C35-50/60C EL296UH110XE60C 826732514ACX-060-230 TXV 56500 14 11.7 C35-50/60C SL280UH090V60C 826732614ACX-060-230 TXV 56500 14 11.7 C35-50/60C SL280UH090XV60C 826732714ACX-060-230 TXV 59000 14.7 12.2 C35-60C EL180UH090E60C 826733214ACX-060-230 TXV 58500 14.7 12.2 C35-60C EL180UH110E60C 826733114ACX-060-230 TXV 58500 14.7 12.2 C35-60C EL180UH110XE60C 826733014ACX-060-230 TXV 58500 14.5 12 C35-60C EL195UH110XE60C 826734114ACX-060-230 TXV 58000 14.5 12 C35-60C EL296UH090XV60C 826733514ACX-060-230 TXV 58500 14.5 12 C35-60C EL296UH110XE60C 826734214ACX-060-230 TXV 58000 14.5 12.2 C35-60C EL296UH110XV60C 826733614ACX-060-230 TXV 59000 14.7 12.2 C35-60C SL280UH090V60C 826733714ACX-060-230 TXV 59000 14.7 12.2 C35-60C SL280UH090XV60C 826733914ACX-060-230 TXV 58500 14.5 12.2 C35-60C SL280UH110V60C 826733814ACX-060-230 TXV 58500 14.5 12.2 C35-60C SL280UH110XV60C 826734014ACX-060-230 TXV 58500 14.5 12 C35-60C SLO185B124/141V60 826732914ACX-060-230 TXV 58000 14.5 12 C35-60C SLP98UH090XV60C 826733314ACX-060-230 TXV 58000 14.5 12.2 C35-60C SLP98UH110XV60C 8267334NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 34

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-060-230 TXV 59000 14.2 12 C35-60C 826732814ACX-060-230 TXV 58500 14.5 12.2 C35-60D EL180UH135E60D 826734414ACX-060-230 TXV 58500 14.2 11.7 C35-60D EL195UH135XE60D 826734714ACX-060-230 TXV 58500 14.2 11.7 C35-60D EL296UH135XE60D 826734814ACX-060-230 TXV 57500 14.5 12 C35-60D EL296UH135XV60D 826734914ACX-060-230 TXV 58000 15 12.2 C35-60D SL280UH135V60D 826734514ACX-060-230 TXV 57500 14.5 12 C35-60D SLP98UH135XV60D 826734614ACX-060-230 TXV 58500 14 11.7 C35-60D 826734314ACX-060-230 TXV 58000 14.5 12 CBA27UHE-060 1025938614ACX-060-230 TXV 58000 14 11.7 CBX25UH-060 573279314ACX-060-230 TXV 58500 14.5 12.2 CBX25UHV-060 697013514ACX-060-230 TXV 58000 14.5 12 CBX27UH-060 569772414ACX-060-230 TXV 57500 14.2 11.7 CBX32M-060 569772614ACX-060-230 TXV 57000 14.2 11.7 CBX32MV-048 569772714ACX-060-230 TXV 57500 14.2 12 CBX32MV-060 569772814ACX-060-230 TXV 57500 14.5 12 CBX32MV-068 569772914ACX-060-230 TXV 57500 14.2 12 CBX40UHV-060 910579014ACX-060-230 TXV 58500 14.7 12.2 CH23-65 EL180UH090E60C 573696314ACX-060-230 TXV 58500 14.5 12.2 CH23-65 EL180UH110E60C 573874314ACX-060-230 TXV 59000 14.7 12.2 CH23-68 EL180UH135E60D 574598014ACX-060-230 TXV 59000 14.2 12 CH23-68 EL195UH135XE60D 569773314ACX-060-230 TXV 57500 14.5 12 CH23-68 EL296UH090XV60C 569773514ACX-060-230 TXV 58500 14.5 12 CH23-68 EL296UH110XV60C 569773614ACX-060-230 TXV 59000 14.2 12 CH23-68 EL296UH135XE60D 569773414ACX-060-230 TXV 59000 14.5 12.2 CH23-68 EL296UH135XV60D 569773714ACX-060-230 TXV 58000 14.5 12.2 CH23-68 SL280UH110V60C 569773914ACX-060-230 TXV 58500 15 12.5 CH23-68 SL280UH135V60D 569774014ACX-060-230 TXV 58500 14.2 11.7 CH23-68 569773214ACX-060-230 TXV 58000 14.5 12 CH33-49 EL180UH090E60C 573696514ACX-060-230 TXV 58000 14.2 12 CH33-49 EL180UH110E60C 573874414ACX-060-230 TXV 58000 14.2 12 CH33-49 EL195UH110XE60C 569774214ACX-060-230 TXV 57500 14.2 11.7 CH33-49 EL296UH090XV60C 569774414ACX-060-230 TXV 58000 14.2 12 CH33-49 EL296UH110XE60C 569774314ACX-060-230 TXV 58000 14.2 11.7 CH33-49 EL296UH110XV60C 569774514ACX-060-230 TXV 58000 14.5 12 CH33-49 SL280UH090V60C 569774814ACX-060-230 TXV 58000 14.2 12 CH33-49 SL280UH110V60C 569774914ACX-060-230 TXV 57500 14.2 11.7 CH33-49 SLP98UH090XV60C 569775014ACX-060-230 TXV 57500 14.2 12 CH33-49 SLP98UH110XV60C 569775114ACX-060-230 TXV 58000 14 11.7 CH33-49 569774114ACX-060-230 TXV 57500 14.2 11.7 CH33-50/60C SL280UH090V60C 569783514ACX-060-230 TXV 57500 14 11.7 CH33-50/60C SL280UH110V60C 569783614ACX-060-230 TXV 58000 14 11.7 CH33-50/60C 569775214ACX-060-230 TXV 57500 14.2 12 CH33-60D EL180UH135E60D 574598114ACX-060-230 TXV 57500 14 11.7 CH33-60D EL195UH135XE60D 569775814ACX-060-230 TXV 57500 14 11.7 CH33-60D EL296UH135XE60D 569775914ACX-060-230 TXV 57500 14.2 11.7 CH33-60D EL296UH135XV60D 569776014ACX-060-230 TXV 57000 14.7 12.2 CH33-60D SL280UH135V60D 569776214ACX-060-230 TXV 57500 14.2 12 CH33-60D SLP98UH135XV60D 569776314ACX-060-230 TXV 58000 14.5 12 CH33-62D EL180UH135E60D 5745982NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 35

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-060-230 TXV 58000 14.2 11.7 CH33-62D EL195UH135XE60D 569776514ACX-060-230 TXV 58000 14.2 11.7 CH33-62D EL296UH135XE60D 569776614ACX-060-230 TXV 58000 14.2 12 CH33-62D EL296UH135XV60D 569964714ACX-060-230 TXV 57500 14.7 12.2 CH33-62D SL280UH135V60D 569783714ACX-060-230 TXV 57500 14.5 12 CH33-62D SLP98UH135XV60D 569776814ACX-060-230 TXV 57500 14 11.7 CH33-62D 569776414ACX-060-230 TXV 59000 14 11.7 CH35-51C EL180UH110E60C 716353214ACX-060-230 TXV 57500 14.25 11.7 CH35-51C EL296UH090XV60C 716352814ACX-060-230 TXV 58000 14.25 11.7 CH35-51C EL296UH110XV60C 716352914ACX-060-230 TXV 58000 14.25 12 CH35-51C SL280UH090V60C 716355014ACX-060-230 TXV 58000 14.25 11.7 CH35-51C SL280UH110V60C 716355114ACX-060-230 TXV 57500 14.25 11.7 CH35-51C SLP98UH090XV60C 716353314ACX-060-230 TXV 57500 14.5 12 CH35-51C SLP98UH110XV60C 716353414ACX-060-230 TXV 58500 14 11.7 CH35-51C 716352614ACX-060-230 TXV 58500 14.5 12 CH35-60D EL180UH135E60D 716353914ACX-060-230 TXV 58000 14.25 11.7 CH35-60D EL195UH135XE60D 716353614ACX-060-230 TXV 58000 14.25 11.7 CH35-60D EL296UH135XE60D 716353814ACX-060-230 TXV 58500 14.25 12 CH35-60D EL296UH135XV60D 716353714ACX-060-230 TXV 57500 14.5 12 CH35-60D SL280UH135V60D 716355214ACX-060-230 TXV 58000 14.5 12 CH35-60D SLP98UH135XV60D 716354014ACX-060-230 TXV 58000 14 11.7 CH35-60D 716353514ACX-060-230 TXV 57000 14.2 12 CR33-50/60 EL180DF110E60C 573357914ACX-060-230 TXV 57000 14.2 12 CR33-50/60 EL195DF110XE60C 569777014ACX-060-230 TXV 57000 14.2 12 CR33-50/60 EL296DF110XE60C 569777114ACX-060-230 TXV 56500 14 11.7 CR33-50/60 SL280DF090V60C 569777514ACX-060-230 TXV 56500 14.2 11.7 CR33-50/60 SL280DF110V60C 569777614ACX-060-230 TXV 58000 14.5 12 CX35-49C EL180UH090E60C 826735314ACX-060-230 TXV 57500 14.2 12 CX35-49C EL180UH110E60C 826735214ACX-060-230 TXV 57500 14.2 12 CX35-49C EL180UH110XE60C 826735114ACX-060-230 TXV 57500 14.2 12 CX35-49C EL195UH110XE60C 826735914ACX-060-230 TXV 57000 14.2 11.7 CX35-49C EL296UH090XV60C 826736114ACX-060-230 TXV 57500 14.2 12 CX35-49C EL296UH110XE60C 826736014ACX-060-230 TXV 57000 14.2 12 CX35-49C EL296UH110XV60C 826736214ACX-060-230 TXV 58000 14.2 12 CX35-49C SL280UH090V60C 826736314ACX-060-230 TXV 58000 14.2 12 CX35-49C SL280UH090XV60C 826735514ACX-060-230 TXV 57500 14.2 12 CX35-49C SL280UH110V60C 826735414ACX-060-230 TXV 57500 14.2 12 CX35-49C SL280UH110XV60C 826735614ACX-060-230 TXV 57000 14.2 11.7 CX35-49C SLP98UH090XV60C 826735714ACX-060-230 TXV 57000 14.2 12 CX35-49C SLP98UH110XV60C 826735814ACX-060-230 TXV 58000 14 11.7 CX35-49C 826735014ACX-060-230 TXV 56500 14.2 11.7 CX35-50/60C EL180UH090E60C 826736614ACX-060-230 TXV 56500 14 11.7 CX35-50/60C EL180UH110E60C 826736414ACX-060-230 TXV 56500 14 11.7 CX35-50/60C EL180UH110XE60C 826736514ACX-060-230 TXV 56500 14 11.7 CX35-50/60C EL195UH110XE60C 826737014ACX-060-230 TXV 56500 14 11.7 CX35-50/60C EL296UH110XE60C 826736714ACX-060-230 TXV 56500 14 11.7 CX35-50/60C SL280UH090V60C 826736814ACX-060-230 TXV 56500 14 11.7 CX35-50/60C SL280UH090XV60C 826736914ACX-060-230 TXV 59000 14.7 12.2 CX35-60C EL180UH090E60C 826737514ACX-060-230 TXV 58500 14.7 12.2 CX35-60C EL180UH110E60C 8267374NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 36

AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-060-230 TXV 58500 14.7 12.2 CX35-60C EL180UH110XE60C 826737314ACX-060-230 TXV 58500 14.5 12 CX35-60C EL195UH110XE60C 826738214ACX-060-230 TXV 58000 14.5 12 CX35-60C EL296UH090XV60C 826738414ACX-060-230 TXV 58500 14.5 12 CX35-60C EL296UH110XE60C 826738314ACX-060-230 TXV 58000 14.5 12.2 CX35-60C EL296UH110XV60C 826738514ACX-060-230 TXV 59000 14.7 12.2 CX35-60C SL280UH090V60C 826737614ACX-060-230 TXV 59000 14.7 12.2 CX35-60C SL280UH090XV60C 826737814ACX-060-230 TXV 58500 14.5 12.2 CX35-60C SL280UH110V60C 826737714ACX-060-230 TXV 58500 14.5 12.2 CX35-60C SL280UH110XV60C 826737914ACX-060-230 TXV 58500 14.5 12 CX35-60C SLO185B124/141V60 826737214ACX-060-230 TXV 58000 14.5 12 CX35-60C SLP98UH090XV60C 826738014ACX-060-230 TXV 58000 14.5 12.2 CX35-60C SLP98UH110XV60C 826738114ACX-060-230 TXV 59000 14.2 12 CX35-60C 826737114ACX-060-230 TXV 58500 14.5 12.2 CX35-60D EL180UH135E60D 826738714ACX-060-230 TXV 58500 14.2 11.7 CX35-60D EL195UH135XE60D 826738814ACX-060-230 TXV 58500 14.2 11.7 CX35-60D EL296UH135XE60D 826738914ACX-060-230 TXV 57500 14.5 12 CX35-60D EL296UH135XV60D 826739014ACX-060-230 TXV 58000 15 12.2 CX35-60D SL280UH135V60D 826739114ACX-060-230 TXV 57500 14.5 12 CX35-60D SLP98UH135XV60D 826739214ACX-060-230 TXV 58500 14 11.7 CX35-60D 826738614ACX-060-230 TXV 59000 14.2 12 CX38-62C 10547281NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 37

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS018-230 RFC 18000 14 12.2 C35-18/24A 847102214ACXS018-230 RFC 18000 14 12.2 C35-18/24B 847102314ACXS018-230 RFC 18000 14 12 C35-24A 847102414ACXS018-230 RFC 18000 14 12 C35-24B 847102614ACXS018-230 RFC 18900 14 12 CH33-25A 762528814ACXS018-230 RFC 19200 14.25 12.2 CH33-31A 762530514ACXS018-230 RFC 19100 14.25 12.2 CH33-31B 762530914ACXS018-230 RFC 18000 14 12 CH35-24A 1051452514ACXS018-230 RFC 19000 14 12.2 CR33-30/36A 762534114ACXS018-230 RFC 19000 14 12.2 CR33-30/36B 762534414ACXS018-230 TXV 19700 16 13 C35-24A EL180UH045E36A 826092314ACXS018-230 TXV 19700 16 13 C35-24A EL180UH045XE36A 826092214ACXS018-230 TXV 18800 14 12 C35-24A 826091914ACXS018-230 TXV 19500 15.5 12.5 C35-24B EL180UH070E36B 826176114ACXS018-230 TXV 19500 15.5 12.5 C35-24B EL180UH070XE36B 826175914ACXS018-230 TXV 18000 14.5 12.2 C35-24B EL195UH030XE24B 860632514ACXS018-230 TXV 18000 14.5 12.2 C35-24B EL195UH045XE24B 860632614ACXS018-230 TXV 20000 16 13 C35-24B EL195UH045XE36B 826176214ACXS018-230 TXV 20000 16 13 C35-24B EL296UH045XE36B 826176414ACXS018-230 TXV 20200 16 13 C35-24B EL296UH045XV36B 826176614ACXS018-230 TXV 20200 16 13 C35-24B EL296UH070XV36B 826176714ACXS018-230 TXV 20200 16 13 C35-24B SLP98UH070XV36B 826175814ACXS018-230 TXV 18800 14 12 C35-24B 826175514ACXS018-230 TXV 19900 16 13 C35-30A EL180UH045E36A 826092914ACXS018-230 TXV 19900 16 13 C35-30A EL180UH045XE36A 826093014ACXS018-230 TXV 19000 14 12.2 C35-30A 826092614ACXS018-230 TXV 19700 15.5 12.5 C35-30B EL180UH070E36B 826094114ACXS018-230 TXV 19700 15.5 12.5 C35-30B EL180UH070XE36B 826094214ACXS018-230 TXV 18000 14.5 12.2 C35-30B EL195UH030XE24B 860632714ACXS018-230 TXV 18000 14.5 12.2 C35-30B EL195UH045XE24B 860632814ACXS018-230 TXV 19800 16 13 C35-30B EL195UH045XE36B 826094414ACXS018-230 TXV 19800 16 13 C35-30B EL296UH045XE36B 826093614ACXS018-230 TXV 20400 16 13.5 C35-30B EL296UH045XV36B 826093714ACXS018-230 TXV 20400 16 13.5 C35-30B EL296UH070XV36B 826093914ACXS018-230 TXV 20400 16 13.5 C35-30B SLP98UH070XV36B 826093414ACXS018-230 TXV 19000 14 12.2 C35-30B 826093214ACXS018-230 TXV 19400 16 13 CBA27UHE-018 1025947914ACXS018-230 TXV 19400 16 13 CBA27UHE-024 1025938714ACXS018-230 TXV 18700 14.25 12 CBX25UH-018 762526414ACXS018-230 TXV 18800 14.25 12 CBX25UH-024 762526614ACXS018-230 TXV 19000 15.5 12.5 CBX25UHV-018 762526714ACXS018-230 TXV 19200 16 13 CBX25UHV-024 762526914ACXS018-230 TXV 19700 16 13 CBX27UH-018 762527114ACXS018-230 TXV 19700 16 13 CBX27UH-024 762527314ACXS018-230 TXV 19100 14.5 12.2 CBX32M-018/024 762527414ACXS018-230 TXV 19300 14.5 12.5 CBX32M-030 762527614ACXS018-230 TXV 19600 16 13 CBX32MV-018/024 762527814ACXS018-230 TXV 19700 16 13 CBX32MV-024/030 762528014ACXS018-230 TXV 19900 16 13 CBX40UHV-024 7625281NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 38

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS018-230 TXV 19800 16 13 CBX40UHV-030 762528314ACXS018-230 TXV 17900 14.25 11.5 CH33-18A EL180UH045E36A 762528714ACXS018-230 TXV 17900 14.25 11.5 CH33-18A EL180UH045XE36A 762528514ACXS018-230 TXV 19400 16 13 CH33-19 EL180UH045E36A 762538514ACXS018-230 TXV 19400 16 13 CH33-19 EL180UH045XE36A 762538414ACXS018-230 TXV 18800 14 11.5 CH33-19 762538314ACXS018-230 TXV 19300 16 13 CH33-24/30 EL180UH045E36A 762538814ACXS018-230 TXV 19300 16 13 CH33-24/30 EL180UH045XE36A 762538714ACXS018-230 TXV 18700 14 11.5 CH33-24/30 762538614ACXS018-230 TXV 19800 16 13 CH33-25A EL180UH045E36A 762529414ACXS018-230 TXV 19800 16 13 CH33-25A EL180UH045XE36A 762529214ACXS018-230 TXV 19200 14.5 12.2 CH33-25A 762529014ACXS018-230 TXV 19400 15.5 12.5 CH33-25B EL180UH070E36B 762529914ACXS018-230 TXV 19400 15.5 12.5 CH33-25B EL180UH070XE36B 762529814ACXS018-230 TXV 18000 14.25 12 CH33-25B EL195UH030XE24B 860632914ACXS018-230 TXV 18000 14.25 12 CH33-25B EL195UH045XE24B 860633014ACXS018-230 TXV 19900 16 13 CH33-25B EL195UH045XE36B 762530114ACXS018-230 TXV 19900 16 13 CH33-25B EL296UH045XE36B 762530314ACXS018-230 TXV 20200 16 13 CH33-25B EL296UH045XV36B 762530414ACXS018-230 TXV 19100 14.25 12 CH33-25B 762529614ACXS018-230 TXV 20200 16 13 CH33-31A EL180UH045E36A 762530814ACXS018-230 TXV 20200 16 13 CH33-31A EL180UH045XE36A 762530714ACXS018-230 TXV 19500 14.5 12.2 CH33-31A 762530614ACXS018-230 TXV 19900 16 13 CH33-31B EL180UH070E36B 762531214ACXS018-230 TXV 19900 16 13 CH33-31B EL180UH070XE36B 762531114ACXS018-230 TXV 18000 14.5 12.2 CH33-31B EL195UH030XE24B 860633114ACXS018-230 TXV 18000 14.5 12.2 CH33-31B EL195UH045XE24B 860633214ACXS018-230 TXV 19900 16 13 CH33-31B EL195UH045XE36B 762531314ACXS018-230 TXV 19900 16 13 CH33-31B EL296UH045XE36B 762531414ACXS018-230 TXV 20600 16 13.5 CH33-31B EL296UH045XV36B 762531514ACXS018-230 TXV 19500 14.5 12.2 CH33-31B 762531014ACXS018-230 TXV 19400 16 13 CH35-18A EL180UH045E36A 762531814ACXS018-230 TXV 19400 16 13 CH35-18A EL180UH045XE36A 762531714ACXS018-230 TXV 18800 14 11.5 CH35-18A 762531614ACXS018-230 TXV 19900 16 13 CH35-24A EL180UH045E36A 762532014ACXS018-230 TXV 19900 16 13 CH35-24A EL180UH045XE36A 762532114ACXS018-230 TXV 19300 14.5 12.2 CH35-24A 762531914ACXS018-230 TXV 19500 15.5 12.5 CH35-24B EL180UH070E36B 762532314ACXS018-230 TXV 19500 15.5 12.5 CH35-24B EL180UH070XE36B 762532414ACXS018-230 TXV 18000 14.25 12 CH35-24B EL195UH030XE24B 860633314ACXS018-230 TXV 18000 14.25 12 CH35-24B EL195UH045XE24B 860633414ACXS018-230 TXV 19600 15.5 12.5 CH35-24B EL195UH045XE36B 762532514ACXS018-230 TXV 19600 15.5 12.5 CH35-24B EL296UH045XE36B 762532614ACXS018-230 TXV 20200 16 13 CH35-24B EL296UH045XV36B 762532714ACXS018-230 TXV 19100 14.25 12 CH35-24B 762532214ACXS018-230 TXV 20200 16 13 CH35-30A EL180UH045E36A 762533014ACXS018-230 TXV 20200 16 13 CH35-30A EL180UH045XE36A 762532914ACXS018-230 TXV 19500 14.5 12.2 CH35-30A 762532814ACXS018-230 TXV 19900 16 13 CH35-30B EL180UH070E36B 7625332NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 39

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS018-230 TXV 19900 16 13 CH35-30B EL180UH070XE36B 762533314ACXS018-230 TXV 18000 14.5 12.2 CH35-30B EL195UH030XE24B 860633514ACXS018-230 TXV 18000 14.5 12.2 CH35-30B EL195UH045XE24B 860633614ACXS018-230 TXV 19900 16 13 CH35-30B EL195UH045XE36B 762533414ACXS018-230 TXV 19900 16 13 CH35-30B EL296UH045XE36B 762533514ACXS018-230 TXV 20600 16 13.5 CH35-30B EL296UH045XV36B 762533614ACXS018-230 TXV 19500 14.5 12.2 CH35-30B 762533114ACXS018-230 TXV 19500 16 13 CH35-36A EL180UH045E36A 1049088714ACXS018-230 TXV 19200 15.5 12.5 CR33-18 EL180DF045E36A 762533814ACXS018-230 TXV 18700 14 11.5 CR33-18 762533714ACXS018-230 TXV 18600 15.1 12.5 CR33-24A EL180DF045E36A 762533914ACXS018-230 TXV 18600 14.5 12.5 CR33-24B EL180DF070E36B 762534014ACXS018-230 TXV 19800 16 13 CR33-30/36A EL180DF045E36A 762534314ACXS018-230 TXV 19400 14.5 12.2 CR33-30/36A 762534214ACXS018-230 TXV 19800 15.5 12.5 CR33-30/36B EL180DF070E36B 762534614ACXS018-230 TXV 19400 14.5 12.2 CR33-30/36B 762534514ACXS018-230 TXV 18400 15 12.5 CX35-18/24A EL180UH045E36A 826094614ACXS018-230 TXV 18400 15 12.5 CX35-18/24A EL180UH045XE36A 826094714ACXS018-230 TXV 18500 14.5 12.2 CX35-18/24B EL180UH070E36B 826094914ACXS018-230 TXV 18500 14.5 12.2 CX35-18/24B EL180UH070XE36B 826095114ACXS018-230 TXV 18600 14.5 12.5 CX35-18/24B EL195UH045XE36B 826095214ACXS018-230 TXV 18600 14.5 12.5 CX35-18/24B EL296UH045XE36B 826095414ACXS018-230 TXV 19700 16 13 CX35-24A EL180UH045E36A 826095914ACXS018-230 TXV 19700 16 13 CX35-24A EL180UH045XE36A 826095814ACXS018-230 TXV 19200 14.25 12.2 CX35-24A 826095614ACXS018-230 TXV 19500 15.5 12.5 CX35-24B EL180UH070E36B 826097114ACXS018-230 TXV 19500 15.5 12.5 CX35-24B EL180UH070XE36B 826096914ACXS018-230 TXV 18000 14.5 12.2 CX35-24B EL195UH030XE24B 860634514ACXS018-230 TXV 18000 14.5 12.2 CX35-24B EL195UH045XE24B 860634614ACXS018-230 TXV 20000 16 13 CX35-24B EL195UH045XE36B 826097414ACXS018-230 TXV 20000 16 13 CX35-24B EL296UH045XE36B 826097514ACXS018-230 TXV 20200 16 13 CX35-24B EL296UH045XV36B 826096614ACXS018-230 TXV 20200 16 13 CX35-24B EL296UH070XV36B 826096714ACXS018-230 TXV 20200 16 13 CX35-24B SLP98UH070XV36B 826096414ACXS018-230 TXV 19200 14.25 12.2 CX35-24B 826096114ACXS018-230 TXV 19900 16 13 CX35-30A EL180UH045E36A 826097914ACXS018-230 TXV 19900 16 13 CX35-30A EL180UH045XE36A 826098114ACXS018-230 TXV 19300 14.5 12.2 CX35-30A 826097714ACXS018-230 TXV 19700 15.5 12.5 CX35-30B EL180UH070E36B 826099514ACXS018-230 TXV 19700 15.5 12.5 CX35-30B EL180UH070XE36B 826098614ACXS018-230 TXV 18000 14.5 12.2 CX35-30B EL195UH030XE24B 860634714ACXS018-230 TXV 18000 14.5 12.2 CX35-30B EL195UH045XE24B 860634814ACXS018-230 TXV 19800 16 13 CX35-30B EL195UH045XE36B 826098814ACXS018-230 TXV 19800 16 13 CX35-30B EL296UH045XE36B 826099014ACXS018-230 TXV 20400 16 13.5 CX35-30B EL296UH045XV36B 826099214ACXS018-230 TXV 20400 16 13.5 CX35-30B EL296UH070XV36B 826099314ACXS018-230 TXV 20400 16 13.5 CX35-30B SLP98UH070XV36B 826098514ACXS018-230 TXV 19300 14.5 12.2 CX35-30B 826098314ACXS018-230 TXV 19200 14.25 12.2 CX38-25B 10547362NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 40

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS024-230 RFC 23400 14 12.2 C35-24A 847102514ACXS024-230 RFC 23400 14 12 C35-24B 847102714ACXS024-230 RFC 23600 14 12 C35-30/36A 847102814ACXS024-230 RFC 23600 14 12 C35-30/36B 847102914ACXS024-230 RFC 23600 14 12 C35-30/36C 847103014ACXS024-230 RFC 23600 14 12.2 C35-30A 847103114ACXS024-230 RFC 23600 14 12.2 C35-30B 847103414ACXS024-230 RFC 24000 14 12.2 C35-36A 847103714ACXS024-230 RFC 24000 14 12.2 C35-36B 847104014ACXS024-230 RFC 24000 14 12.2 CH33-25A 762517314ACXS024-230 RFC 23800 14 12.2 CH33-25B 762517514ACXS024-230 RFC 24000 14.5 12.2 CH33-31A 762517714ACXS024-230 RFC 24000 14.5 12.2 CH33-31B 762517814ACXS024-230 RFC 23600 14 12 CH33-36A 762482114ACXS024-230 RFC 23800 14 12.2 CH33-36C 762485314ACXS024-230 RFC 24000 14.2 12.2 CH33-42B 762518414ACXS024-230 RFC 24000 14.5 12.2 CH33-43B 762518514ACXS024-230 RFC 23400 14 12.2 CH35-24A 1051452614ACXS024-230 RFC 23400 14 12 CH35-24B 1051452714ACXS024-230 RFC 23600 14 12.2 CH35-30A 1051452814ACXS024-230 RFC 23600 14 12.2 CH35-30B 1051452914ACXS024-230 RFC 23400 14 12 CH35-36A 762519214ACXS024-230 RFC 23400 14 12 CH35-36B 762518014ACXS024-230 RFC 24000 14 12.2 CH35-36C 762519114ACXS024-230 RFC 24000 14 12.2 CR33-30/36A 762518714ACXS024-230 RFC 24000 14 12.2 CR33-30/36B 762518914ACXS024-230 RFC 24000 14 12.2 CR33-30/36C 762518214ACXS024-230 TXV 23400 15.1 12.5 C35-18/24B EL195UH030XE24B 860653814ACXS024-230 TXV 23400 15.1 12.5 C35-18/24B EL195UH045XE24B 860654014ACXS024-230 TXV 24000 16 13 C35-24A EL180UH045E36A 826052214ACXS024-230 TXV 24000 16 13 C35-24A EL180UH045XE36A 826052414ACXS024-230 TXV 24000 16 13 C35-24A SL280UH070V36A 826051914ACXS024-230 TXV 24000 16 13 C35-24A SL280UH070XV36A 826052014ACXS024-230 TXV 24000 14.25 12.2 C35-24A 826051714ACXS024-230 TXV 24000 16 13 C35-24B EL180UH070E36B 826054114ACXS024-230 TXV 24000 16 13 C35-24B EL180UH070XE36B 826054214ACXS024-230 TXV 24000 16 13 C35-24B EL195UH030XE24B 860654114ACXS024-230 TXV 24000 16 13 C35-24B EL195UH045XE24B 860654214ACXS024-230 TXV 24000 16 13 C35-24B EL195UH045XE36B 826052814ACXS024-230 TXV 24000 16 13 C35-24B EL195UH070XE36B 826052914ACXS024-230 TXV 24000 16 13 C35-24B EL296UH045XE36B 826053114ACXS024-230 TXV 24000 16 13 C35-24B EL296UH045XV36B 826053614ACXS024-230 TXV 24000 16 13 C35-24B EL296UH070XE36B 826053214ACXS024-230 TXV 24000 16 13 C35-24B EL296UH070XV36B 826053714ACXS024-230 TXV 24000 16 13 C35-24B SL280UH090V36B 826054414ACXS024-230 TXV 24000 16 13 C35-24B SL280UH090V48B 826054614ACXS024-230 TXV 24000 16 13 C35-24B SL280UH090XV48B 826053414ACXS024-230 TXV 24000 16 13 C35-24B SLP98UH070XV36B 826053914ACXS024-230 TXV 23800 14 12 C35-24B 8260525NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 41

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS024-230 TXV 24000 16 13 C35-30/36A EL180UH045E36A 826058614ACXS024-230 TXV 24000 16 13 C35-30/36A EL180UH045XE36A 826058814ACXS024-230 TXV 24000 16 13 C35-30/36A SL280UH070V36A 826058314ACXS024-230 TXV 24000 16 13 C35-30/36A SL280UH070XV36A 826058414ACXS024-230 TXV 23600 14 12 C35-30/36A 826058014ACXS024-230 TXV 24000 16 13 C35-30/36B EL180UH070E36B 826060714ACXS024-230 TXV 24000 16 13 C35-30/36B EL180UH070XE36B 826060914ACXS024-230 TXV 24000 15.5 12.5 C35-30/36B EL195UH030XE24B 860654414ACXS024-230 TXV 24000 15.5 12.5 C35-30/36B EL195UH045XE24B 860654514ACXS024-230 TXV 23400 15.5 12.5 C35-30/36B EL195UH045XE36B 826061114ACXS024-230 TXV 23600 16 13 C35-30/36B EL195UH070XE36B 826059214ACXS024-230 TXV 23400 15.5 12.5 C35-30/36B EL296UH045XE36B 826059314ACXS024-230 TXV 24000 16 13 C35-30/36B EL296UH045XV36B 826059614ACXS024-230 TXV 23600 16 13 C35-30/36B EL296UH070XE36B 826059514ACXS024-230 TXV 24000 16 13 C35-30/36B EL296UH070XV36B 826059814ACXS024-230 TXV 24000 16 13 C35-30/36B SL280UH090V36B 826060214ACXS024-230 TXV 24000 16 13 C35-30/36B SL280UH090V48B 826060314ACXS024-230 TXV 24000 16 13 C35-30/36B SL280UH090XV48B 826060514ACXS024-230 TXV 24000 16 13 C35-30/36B SLP98UH070XV36B 826060014ACXS024-230 TXV 23600 14 12 C35-30/36B 826058914ACXS024-230 TXV 24000 16 13 C35-30/36C EL296UH090XV36C 826061514ACXS024-230 TXV 24000 16 13 C35-30/36C SLP98UH090XV36C 826061714ACXS024-230 TXV 23600 14 12 C35-30/36C 826061314ACXS024-230 TXV 24000 16 13 C35-30A EL180UH045E36A 826055014ACXS024-230 TXV 24000 16 13 C35-30A EL180UH045XE36A 826055114ACXS024-230 TXV 24000 16 13 C35-30A SL280UH070V36A 826055314ACXS024-230 TXV 24000 16 13 C35-30A SL280UH070XV36A 826055514ACXS024-230 TXV 24000 14.5 12.2 C35-30A 826054814ACXS024-230 TXV 24000 16 13 C35-30B EL180UH070E36B 826057814ACXS024-230 TXV 24000 16 13 C35-30B EL180UH070XE36B 826056214ACXS024-230 TXV 24000 16 13 C35-30B EL195UH030XE24B 860654714ACXS024-230 TXV 24000 16 13 C35-30B EL195UH045XE24B 860654814ACXS024-230 TXV 24000 16 13 C35-30B EL195UH045XE36B 826056414ACXS024-230 TXV 24000 16 13 C35-30B EL195UH070XE36B 826056514ACXS024-230 TXV 24000 16 13 C35-30B EL296UH045XE36B 826056714ACXS024-230 TXV 24000 16 13 C35-30B EL296UH045XV36B 826057114ACXS024-230 TXV 24000 16 13 C35-30B EL296UH070XE36B 826056914ACXS024-230 TXV 24000 16 13 C35-30B EL296UH070XV36B 826055914ACXS024-230 TXV 24000 16 13 C35-30B SL280UH090V36B 826057314ACXS024-230 TXV 24000 16 13 C35-30B SL280UH090V48B 826057514ACXS024-230 TXV 24000 16 13 C35-30B SL280UH090XV48B 826057614ACXS024-230 TXV 24000 16 13 C35-30B SLP98UH070XV36B 826056014ACXS024-230 TXV 24000 14.5 12.2 C35-30B 826055614ACXS024-230 TXV 24000 16 13 C35-36A EL180UH045E36A 826062414ACXS024-230 TXV 24000 16 13 C35-36A EL180UH045XE36A 826062614ACXS024-230 TXV 24000 16 13.5 C35-36A SL280UH070V36A 826062014ACXS024-230 TXV 24000 16 13.5 C35-36A SL280UH070XV36A 826062214ACXS024-230 TXV 24000 14.5 12.5 C35-36A 826061814ACXS024-230 TXV 24000 16 13.5 C35-36B EL180UH070E36B 8260645NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 42

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS024-230 TXV 24000 16 13.5 C35-36B EL180UH070XE36B 826064714ACXS024-230 TXV 24000 16 13 C35-36B EL195UH030XE24B 860655014ACXS024-230 TXV 24000 16 13 C35-36B EL195UH045XE24B 860655114ACXS024-230 TXV 24000 16 13 C35-36B EL195UH045XE36B 826064914ACXS024-230 TXV 24000 16 13 C35-36B EL195UH070XE36B 826063014ACXS024-230 TXV 24000 16 13 C35-36B EL296UH045XE36B 826063214ACXS024-230 TXV 24000 16 13 C35-36B EL296UH045XV36B 826063614ACXS024-230 TXV 24000 16 13 C35-36B EL296UH070XE36B 826063414ACXS024-230 TXV 24000 16 13 C35-36B EL296UH070XV36B 826063714ACXS024-230 TXV 24000 16 13.5 C35-36B SL280UH090V36B 826064114ACXS024-230 TXV 24000 16 13 C35-36B SL280UH090V48B 826064214ACXS024-230 TXV 24000 16 13 C35-36B SL280UH090XV48B 826064414ACXS024-230 TXV 24000 16 13 C35-36B SLP98UH070XV36B 826063914ACXS024-230 TXV 24000 14.5 12.5 C35-36B 826062814ACXS024-230 TXV 24000 16 13 CBA27UHE-024 1025938814ACXS024-230 TXV 24000 16 13 CBA27UHE-030 1025938914ACXS024-230 TXV 23600 14.5 12.2 CBX25UH-024 762468214ACXS024-230 TXV 23800 14.5 12.2 CBX25UH-030 762468414ACXS024-230 TXV 24000 14.5 12.2 CBX25UH-036 762468514ACXS024-230 TXV 24000 16 13 CBX25UHV-024 762468714ACXS024-230 TXV 24000 16 13 CBX25UHV-030 762468914ACXS024-230 TXV 24000 16 13 CBX25UHV-036 762469014ACXS024-230 TXV 24000 16 13 CBX27UH-024 762469214ACXS024-230 TXV 24000 16 13 CBX27UH-030 762469414ACXS024-230 TXV 23800 14.5 12.2 CBX32M-018/024 762469514ACXS024-230 TXV 24000 15.1 12.5 CBX32M-030 762469714ACXS024-230 TXV 24000 15.5 12.5 CBX32MV-018/024 762469814ACXS024-230 TXV 24000 16 13 CBX32MV-024/030 762470014ACXS024-230 TXV 24000 16 13 CBX40UHV-024 1009092814ACXS024-230 TXV 22800 15.1 12.5 CH23-31 EL180UH045E36A 762470314ACXS024-230 TXV 22800 15.1 12.5 CH23-31 EL180UH045XE36A 762470514ACXS024-230 TXV 23200 15.5 12.5 CH23-31 EL180UH070E36B 762470714ACXS024-230 TXV 23200 15.5 12.5 CH23-31 EL180UH070XE36B 762470814ACXS024-230 TXV 22800 14.5 12.5 CH23-31 EL195UH030XE24B 860655314ACXS024-230 TXV 22800 14.5 12.5 CH23-31 EL195UH045XE24B 860655414ACXS024-230 TXV 23000 15.1 12.5 CH23-31 EL195UH045XE36B 762471014ACXS024-230 TXV 23000 15.1 12.5 CH23-31 EL195UH070XE36B 762471114ACXS024-230 TXV 23000 15.1 12.5 CH23-31 EL296UH045XE36B 762471314ACXS024-230 TXV 23200 15.5 12.5 CH23-31 EL296UH045XV36B 762471614ACXS024-230 TXV 23000 15.1 12.5 CH23-31 EL296UH070XE36B 762471514ACXS024-230 TXV 23200 15.5 13 CH23-31 EL296UH070XV36B 762471814ACXS024-230 TXV 23400 15.1 13 CH23-31 SL280UH070V36A 778657214ACXS024-230 TXV 23200 16 13 CH23-31 SL280UH090V36B 762470214ACXS024-230 TXV 23200 15.5 13 CH23-31 SLP98UH070XV36B 762472014ACXS024-230 TXV 24000 16 13 CH23-41 EL180UH045E36A 762472814ACXS024-230 TXV 24000 16 13 CH23-41 EL180UH045XE36A 762473014ACXS024-230 TXV 24000 16 13 CH23-41 EL180UH070E36B 762473114ACXS024-230 TXV 24000 16 13 CH23-41 EL180UH070XE36B 762473314ACXS024-230 TXV 24000 15.5 12.5 CH23-41 EL195UH030XE24B 8606556NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 43

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS024-230 TXV 24000 15.5 12.5 CH23-41 EL195UH045XE24B 860655714ACXS024-230 TXV 24000 16 13 CH23-41 EL195UH045XE36B 762473514ACXS024-230 TXV 24000 16 13 CH23-41 EL195UH070XE36B 762473614ACXS024-230 TXV 24000 16 13 CH23-41 EL296UH045XE36B 762473814ACXS024-230 TXV 24000 16 13 CH23-41 EL296UH045XV36B 762474214ACXS024-230 TXV 24000 16 13 CH23-41 EL296UH070XE36B 762474014ACXS024-230 TXV 24000 16 13 CH23-41 EL296UH070XV36B 762474314ACXS024-230 TXV 24000 16 13 CH23-41 SL280UH070V36A 762472514ACXS024-230 TXV 24000 16 13 CH23-41 SL280UH090V36B 762472614ACXS024-230 TXV 24000 16 13 CH23-41 SLP98UH070XV36B 762474514ACXS024-230 TXV 23800 14.5 12 CH23-41 762472314ACXS024-230 TXV 23800 15.5 12.5 CH33-19 EL180UH045E36A 762475214ACXS024-230 TXV 23800 15.5 12.5 CH33-19 EL180UH045XE36A 762475414ACXS024-230 TXV 24000 15.1 13 CH33-19 SL280UH070V36A 762474914ACXS024-230 TXV 24000 15.1 13 CH33-19 SL280UH070XV36A 762475014ACXS024-230 TXV 23200 14 11.5 CH33-19 762474714ACXS024-230 TXV 23800 15.5 12.5 CH33-24/30 EL180UH045E36A 762476114ACXS024-230 TXV 23800 15.5 12.5 CH33-24/30 EL180UH045XE36A 762476314ACXS024-230 TXV 23800 15.1 13 CH33-24/30 SL280UH070V36A 762475814ACXS024-230 TXV 23800 15.1 13 CH33-24/30 SL280UH070XV36A 762475914ACXS024-230 TXV 23200 14 11.5 CH33-24/30 762475614ACXS024-230 TXV 24000 16 13 CH33-25A EL180UH045E36A 762477014ACXS024-230 TXV 24000 16 13 CH33-25A EL180UH045XE36A 762477214ACXS024-230 TXV 24000 16 13 CH33-25A SL280UH070V36A 762476614ACXS024-230 TXV 24000 16 13 CH33-25A SL280UH070XV36A 762476814ACXS024-230 TXV 24000 14.5 12.2 CH33-25A 762476514ACXS024-230 TXV 24000 16 13 CH33-25B EL180UH070E36B 762477714ACXS024-230 TXV 24000 16 13 CH33-25B EL180UH070XE36B 762477914ACXS024-230 TXV 24000 15.5 12.5 CH33-25B EL195UH030XE24B 860655814ACXS024-230 TXV 24000 15.5 12.5 CH33-25B EL195UH045XE24B 860656014ACXS024-230 TXV 24000 16 13 CH33-25B EL195UH045XE36B 762478014ACXS024-230 TXV 24000 16 13 CH33-25B EL195UH070XE36B 762478214ACXS024-230 TXV 24000 16 13 CH33-25B EL296UH045XE36B 762478414ACXS024-230 TXV 24000 16 13 CH33-25B EL296UH045XV36B 762478714ACXS024-230 TXV 24000 16 13 CH33-25B EL296UH070XE36B 762478614ACXS024-230 TXV 24000 16 13 CH33-25B EL296UH070XV36B 762478914ACXS024-230 TXV 24000 16 13 CH33-25B SL280UH090V36B 762477514ACXS024-230 TXV 24000 16 13 CH33-25B SLP98UH070XV36B 762479114ACXS024-230 TXV 23800 14.5 12 CH33-25B 762477314ACXS024-230 TXV 24000 16 13 CH33-31A EL180UH045E36A 762479814ACXS024-230 TXV 24000 16 13 CH33-31A EL180UH045XE36A 762480014ACXS024-230 TXV 24000 16 13 CH33-31A SL280UH070V36A 762479514ACXS024-230 TXV 24000 16 13 CH33-31A SL280UH070XV36A 762479614ACXS024-230 TXV 24000 14.5 12.5 CH33-31A 762479314ACXS024-230 TXV 24000 16 13.5 CH33-31B EL180UH070E36B 762480514ACXS024-230 TXV 24000 16 13.5 CH33-31B EL180UH070XE36B 762480714ACXS024-230 TXV 24000 16 13 CH33-31B EL195UH030XE24B 860656114ACXS024-230 TXV 24000 16 13 CH33-31B EL195UH045XE24B 860656314ACXS024-230 TXV 24000 16 13 CH33-31B EL195UH045XE36B 7624809NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS024-230 TXV 24000 16 13 CH33-31B EL195UH070XE36B 762481014ACXS024-230 TXV 24000 16 13 CH33-31B EL296UH045XE36B 762481214ACXS024-230 TXV 24000 16 13 CH33-31B EL296UH045XV36B 762481614ACXS024-230 TXV 24000 16 13 CH33-31B EL296UH070XE36B 762481414ACXS024-230 TXV 24000 16 13 CH33-31B EL296UH070XV36B 762481714ACXS024-230 TXV 24000 16 13.5 CH33-31B SL280UH090V36B 762480314ACXS024-230 TXV 24000 16 13 CH33-31B SLP98UH070XV36B 762481914ACXS024-230 TXV 24000 14.5 12.5 CH33-31B 762480214ACXS024-230 TXV 24000 16 13 CH33-36A EL180UH045E36A 762482814ACXS024-230 TXV 24000 16 13 CH33-36A EL180UH045XE36A 762483014ACXS024-230 TXV 24000 16 13 CH33-36A SL280UH070V36A 762482514ACXS024-230 TXV 24000 16 13 CH33-36A SL280UH070XV36A 762482614ACXS024-230 TXV 23800 14.25 12 CH33-36A 762482314ACXS024-230 TXV 24000 16 13 CH33-36B EL180UH070E36B 762483714ACXS024-230 TXV 24000 16 13 CH33-36B EL180UH070XE36B 762483914ACXS024-230 TXV 24000 15.5 12.5 CH33-36B EL195UH030XE24B 860656414ACXS024-230 TXV 24000 15.5 12.5 CH33-36B EL195UH045XE24B 860656514ACXS024-230 TXV 24000 16 13 CH33-36B EL195UH045XE36B 762484014ACXS024-230 TXV 24000 16 13 CH33-36B EL195UH070XE36B 762484214ACXS024-230 TXV 24000 16 13 CH33-36B EL296UH045XE36B 762484414ACXS024-230 TXV 24000 16 13 CH33-36B EL296UH045XV36B 762484714ACXS024-230 TXV 24000 16 13 CH33-36B EL296UH070XE36B 762484614ACXS024-230 TXV 24000 16 13 CH33-36B EL296UH070XV36B 762484914ACXS024-230 TXV 24000 16 13 CH33-36B SL280UH090V36B 762483514ACXS024-230 TXV 24000 16 13 CH33-36B SLP98UH070XV36B 762485114ACXS024-230 TXV 23800 14.5 12 CH33-36B 762483314ACXS024-230 TXV 24000 16 13 CH33-36C EL296UH090XV36C 762485614ACXS024-230 TXV 24000 16 13 CH33-36C SLP98UH090XV36C 762485814ACXS024-230 TXV 23600 14.2 12 CH33-36C 762485514ACXS024-230 TXV 24000 16 13 CH33-42 EL195UH030XE24B 860656714ACXS024-230 TXV 24000 16 13 CH33-42 EL195UH045XE24B 860656814ACXS024-230 TXV 24000 16 13 CH33-43B EL195UH030XE24B 860657014ACXS024-230 TXV 24000 16 13 CH33-43B EL195UH045XE24B 860657114ACXS024-230 TXV 24000 16 13 CH35-18A EL180UH045E36A 762486514ACXS024-230 TXV 24000 16 13 CH35-18A EL180UH045XE36A 762486714ACXS024-230 TXV 24000 16 13 CH35-18A SL280UH070V36A 762486214ACXS024-230 TXV 24000 16 13 CH35-18A SL280UH070XV36A 762486414ACXS024-230 TXV 23400 14.25 11.5 CH35-18A 762486014ACXS024-230 TXV 24000 16 13 CH35-24A EL180UH045E36A 762487414ACXS024-230 TXV 24000 16 13 CH35-24A EL180UH045XE36A 762487614ACXS024-230 TXV 24000 16 13 CH35-24A SL280UH070V36A 762487114ACXS024-230 TXV 24000 16 13 CH35-24A SL280UH070XV36A 762487214ACXS024-230 TXV 23800 14.5 12.2 CH35-24A 762486914ACXS024-230 TXV 24000 16 13 CH35-24B EL180UH070E36B 762488114ACXS024-230 TXV 24000 16 13 CH35-24B EL180UH070XE36B 762488314ACXS024-230 TXV 24000 15.5 12.5 CH35-24B EL195UH030XE24B 860657214ACXS024-230 TXV 24000 15.5 12.5 CH35-24B EL195UH045XE24B 860657414ACXS024-230 TXV 24000 16 13 CH35-24B EL195UH045XE36B 762488514ACXS024-230 TXV 24000 16 13 CH35-24B EL195UH070XE36B 7624887NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS024-230 TXV 24000 16 13 CH35-24B EL296UH045XV36B 762488814ACXS024-230 TXV 24000 16 13 CH35-24B EL296UH070XV36B 762489014ACXS024-230 TXV 24000 16 13 CH35-24B SL280UH090V36B 762488014ACXS024-230 TXV 24000 16 13 CH35-24B SLP98UH070XV36B 762489214ACXS024-230 TXV 24000 14.5 12.2 CH35-24B 762487814ACXS024-230 TXV 24000 16 13 CH35-30A EL180UH045E36A 762489914ACXS024-230 TXV 24000 16 13 CH35-30A EL180UH045XE36A 762490114ACXS024-230 TXV 24000 16 13 CH35-30A SL280UH070V36A 762489614ACXS024-230 TXV 24000 16 13 CH35-30A SL280UH070XV36A 762489714ACXS024-230 TXV 24000 15 12.5 CH35-30A 762489414ACXS024-230 TXV 24000 16 13.5 CH35-30B EL180UH070E36B 762490614ACXS024-230 TXV 24000 16 13.5 CH35-30B EL180UH070XE36B 762490814ACXS024-230 TXV 24000 16 13 CH35-30B EL195UH030XE24B 860657514ACXS024-230 TXV 24000 16 13 CH35-30B EL195UH045XE24B 860657714ACXS024-230 TXV 24000 16 13 CH35-30B EL195UH045XE36B 762491014ACXS024-230 TXV 24000 16 13 CH35-30B EL195UH070XE36B 762491114ACXS024-230 TXV 24000 16 13 CH35-30B EL296UH045XV36B 762491314ACXS024-230 TXV 24000 16 13 CH35-30B EL296UH070XV36B 762491514ACXS024-230 TXV 24000 16 13.5 CH35-30B SL280UH090V36B 762490414ACXS024-230 TXV 24000 16 13 CH35-30B SLP98UH070XV36B 762491714ACXS024-230 TXV 24000 14.5 12.5 CH35-30B 762490314ACXS024-230 TXV 24000 16 13 CH35-36A EL180UH045E36A 762492414ACXS024-230 TXV 24000 16 13 CH35-36A EL180UH045XE36A 762492514ACXS024-230 TXV 24000 16 13 CH35-36A SL280UH070V36A 762492014ACXS024-230 TXV 24000 16 13 CH35-36A SL280UH070XV36A 762492214ACXS024-230 TXV 23800 14.25 12.2 CH35-36A 762491814ACXS024-230 TXV 24000 16 13 CH35-36B EL180UH070E36B 762493114ACXS024-230 TXV 24000 16 13 CH35-36B EL180UH070XE36B 762493314ACXS024-230 TXV 24000 15.5 12.5 CH35-36B EL195UH030XE24B 860657814ACXS024-230 TXV 24000 15.5 12.5 CH35-36B EL195UH045XE24B 860658014ACXS024-230 TXV 24000 16 13 CH35-36B EL195UH045XE36B 762493414ACXS024-230 TXV 24000 16 13 CH35-36B EL195UH070XE36B 762493614ACXS024-230 TXV 24000 16 13 CH35-36B EL296UH045XV36B 762493814ACXS024-230 TXV 24000 16 13 CH35-36B EL296UH070XV36B 762494014ACXS024-230 TXV 24000 16 13 CH35-36B SL280UH090V36B 762492914ACXS024-230 TXV 24000 16 13 CH35-36B SLP98UH070XV36B 762494114ACXS024-230 TXV 23800 14 12.2 CH35-36B 762492714ACXS024-230 TXV 24000 16 13 CH35-36C EL296UH090XV36C 762494514ACXS024-230 TXV 24000 16 13 CH35-36C SLP98UH090XV36C 762494714ACXS024-230 TXV 24000 14.25 12.2 CH35-36C 762494314ACXS024-230 TXV 23400 15.1 12.5 CR33-24A EL180DF045E36A 762495014ACXS024-230 TXV 23000 15.1 12.5 CR33-24A SL280DF070V36A 762494814ACXS024-230 TXV 23000 15.1 12.5 CR33-24B EL180DF070E36B 762495214ACXS024-230 TXV 22600 15 12.5 CR33-24B EL195DF045XE36B 762495414ACXS024-230 TXV 22800 15 12.5 CR33-24B EL195DF070XE48B 762495514ACXS024-230 TXV 22600 15 12.5 CR33-24B EL296DF045XE36B 762495714ACXS024-230 TXV 23000 15.1 12.5 CR33-24B EL296DF045XV36B 762496114ACXS024-230 TXV 22800 15 12.5 CR33-24B EL296DF070XE48B 762495914ACXS024-230 TXV 23200 15.1 12.5 CR33-24B SLP98DF070XV36B 7624962NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 46

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS024-230 TXV 24000 16 13 CR33-30/36A EL180DF045E36A 762496814ACXS024-230 TXV 24000 16 13 CR33-30/36A SL280DF070V36A 762496614ACXS024-230 TXV 24000 14.5 12.2 CR33-30/36A 762496414ACXS024-230 TXV 24000 16 13 CR33-30/36B EL180DF070E36B 762497114ACXS024-230 TXV 24000 16 13 CR33-30/36B EL195DF045XE36B 762497314ACXS024-230 TXV 24000 16 13 CR33-30/36B EL195DF070XE48B 762497414ACXS024-230 TXV 24000 16 13 CR33-30/36B EL296DF045XE36B 762497614ACXS024-230 TXV 24000 16 13 CR33-30/36B EL296DF045XV36B 762498114ACXS024-230 TXV 24000 16 13 CR33-30/36B EL296DF070XE48B 762497814ACXS024-230 TXV 24000 16 13 CR33-30/36B EL296DF070XV48B 762498214ACXS024-230 TXV 24000 16 13 CR33-30/36B SL280DF090V48B 762497914ACXS024-230 TXV 24000 16 13 CR33-30/36B SLP98DF070XV36B 762498414ACXS024-230 TXV 24000 14.5 12.2 CR33-30/36B 762496914ACXS024-230 TXV 24000 16 13 CR33-30/36C SLP98DF090XV36C 762498814ACXS024-230 TXV 24000 14.5 12.2 CR33-30/36C 762498614ACXS024-230 TXV 22800 15 12.5 CX35-18/24A EL180UH045E36A 826065114ACXS024-230 TXV 22800 15 12.5 CX35-18/24A EL180UH045XE36A 826065214ACXS024-230 TXV 23400 15.1 12.5 CX35-18/24B EL195UH030XE24B 860659914ACXS024-230 TXV 23400 15 12.5 CX35-18/24B EL195UH045XE24B 860660014ACXS024-230 TXV 24000 16 13 CX35-24A EL180UH045E36A 826065914ACXS024-230 TXV 23600 15.5 11.5 CX35-24A EL180UH045XE36A 826066114ACXS024-230 TXV 24000 16 13 CX35-24A SL280UH070V36A 826065614ACXS024-230 TXV 24000 16 13 CX35-24A SL280UH070XV36A 826065714ACXS024-230 TXV 24000 14.25 12.2 CX35-24A 826065414ACXS024-230 TXV 24000 16 13 CX35-24B EL180UH070E36B 826066414ACXS024-230 TXV 24000 16 13 CX35-24B EL180UH070XE36B 826066614ACXS024-230 TXV 24000 16 13 CX35-24B EL195UH030XE24B 860660214ACXS024-230 TXV 24000 16 13 CX35-24B EL195UH045XE24B 860660314ACXS024-230 TXV 24000 16 13 CX35-24B EL195UH045XE36B 826066814ACXS024-230 TXV 24000 16 13 CX35-24B EL195UH070XE36B 826066914ACXS024-230 TXV 24000 16 13 CX35-24B EL296UH045XE36B 826067114ACXS024-230 TXV 24000 16 13 CX35-24B EL296UH045XV36B 826067914ACXS024-230 TXV 24000 16 13 CX35-24B EL296UH070XE36B 826067314ACXS024-230 TXV 24000 16 13 CX35-24B EL296UH070XV36B 826068114ACXS024-230 TXV 24000 16 13 CX35-24B SL280UH090V36B 826067414ACXS024-230 TXV 24000 16 13 CX35-24B SL280UH090V48B 826067614ACXS024-230 TXV 24000 16 13 CX35-24B SL280UH090XV48B 826067814ACXS024-230 TXV 24000 16 13 CX35-24B SLP98UH070XV36B 826068314ACXS024-230 TXV 24000 14.25 12.2 CX35-24B 826066214ACXS024-230 TXV 24000 16 13 CX35-30/36A EL180UH045E36A 826071814ACXS024-230 TXV 24000 16 13 CX35-30/36A EL180UH045XE36A 826071614ACXS024-230 TXV 24000 16 13 CX35-30/36A SL280UH070V36A 826071914ACXS024-230 TXV 24000 16 13 CX35-30/36A SL280UH070XV36A 826072114ACXS024-230 TXV 23800 14.5 12 CX35-30/36A 826071414ACXS024-230 TXV 24000 16 13 CX35-30/36B EL180UH070E36B 826074414ACXS024-230 TXV 24000 16 13 CX35-30/36B EL180UH070XE36B 826072814ACXS024-230 TXV 24000 15.5 12.5 CX35-30/36B EL195UH030XE24B 860660514ACXS024-230 TXV 24000 15.5 12.5 CX35-30/36B EL195UH045XE24B 860660614ACXS024-230 TXV 23400 15.5 12.5 CX35-30/36B EL195UH045XE36B 8260730NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 47

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS024-230 TXV 23600 16 13 CX35-30/36B EL195UH070XE36B 826073114ACXS024-230 TXV 23400 15.5 12.5 CX35-30/36B EL296UH045XE36B 826073314ACXS024-230 TXV 24000 16 13 CX35-30/36B EL296UH045XV36B 826073614ACXS024-230 TXV 23600 16 13 CX35-30/36B EL296UH070XE36B 826073514ACXS024-230 TXV 24000 16 13 CX35-30/36B EL296UH070XV36B 826072514ACXS024-230 TXV 24000 16 13 CX35-30/36B SL280UH090V36B 826073814ACXS024-230 TXV 24000 16 13 CX35-30/36B SL280UH090V48B 826073914ACXS024-230 TXV 24000 16 13 CX35-30/36B SL280UH090XV48B 826074114ACXS024-230 TXV 24000 16 13 CX35-30/36B SLP98UH070XV36B 826072614ACXS024-230 TXV 23800 14.5 12 CX35-30/36B 826072314ACXS024-230 TXV 24000 16 13 CX35-30/36C EL296UH090XV36C 826074714ACXS024-230 TXV 24000 16 13 CX35-30/36C SLP98UH090XV36C 826074914ACXS024-230 TXV 23800 14.5 12 CX35-30/36C 826074614ACXS024-230 TXV 24000 16 13 CX35-30A EL180UH045E36A 826068914ACXS024-230 TXV 24000 16 13 CX35-30A EL180UH045XE36A 826069114ACXS024-230 TXV 24000 16 13 CX35-30A SL280UH070V36A 826068614ACXS024-230 TXV 24000 16 13 CX35-30A SL280UH070XV36A 826068814ACXS024-230 TXV 24000 14.5 12.2 CX35-30A 826068414ACXS024-230 TXV 24000 16 13 CX35-30B EL180UH070E36B 826070314ACXS024-230 TXV 24000 16 13 CX35-30B EL180UH070XE36B 826070414ACXS024-230 TXV 24000 16 13 CX35-30B EL195UH030XE24B 860660714ACXS024-230 TXV 24000 16 13 CX35-30B EL195UH045XE24B 860660914ACXS024-230 TXV 24000 16 13 CX35-30B EL195UH045XE36B 826070614ACXS024-230 TXV 24000 16 13 CX35-30B EL195UH070XE36B 826070814ACXS024-230 TXV 24000 16 13 CX35-30B EL296UH045XE36B 826070914ACXS024-230 TXV 24000 16 13 CX35-30B EL296UH045XV36B 826069614ACXS024-230 TXV 24000 16 13 CX35-30B EL296UH070XE36B 826069414ACXS024-230 TXV 24000 16 13 CX35-30B EL296UH070XV36B 826069814ACXS024-230 TXV 24000 16 13 CX35-30B SL280UH090V36B 826071114ACXS024-230 TXV 24000 16 13 CX35-30B SL280UH090V48B 826071314ACXS024-230 TXV 24000 16 13 CX35-30B SL280UH090XV48B 826070114ACXS024-230 TXV 24000 16 13 CX35-30B SLP98UH070XV36B 826069914ACXS024-230 TXV 24000 14.5 12.2 CX35-30B 826069314ACXS024-230 TXV 24000 16 13 CX35-36A EL180UH045E36A 826075214ACXS024-230 TXV 24000 16 13 CX35-36A EL180UH045XE36A 826075414ACXS024-230 TXV 24000 16 13.5 CX35-36A SL280UH070V36A 826075614ACXS024-230 TXV 24000 16 13.5 CX35-36A SL280UH070XV36A 826075714ACXS024-230 TXV 24000 14.5 12.5 CX35-36A 826075114ACXS024-230 TXV 24000 16 13.5 CX35-36B EL180UH070E36B 826077914ACXS024-230 TXV 24000 16 13.5 CX35-36B EL180UH070XE36B 826076414ACXS024-230 TXV 24000 16 13 CX35-36B EL195UH030XE24B 860661014ACXS024-230 TXV 24000 16 13 CX35-36B EL195UH045XE24B 860661214ACXS024-230 TXV 24000 16 13 CX35-36B EL195UH045XE36B 826076614ACXS024-230 TXV 24000 16 13 CX35-36B EL195UH070XE36B 826076714ACXS024-230 TXV 24000 16 13 CX35-36B EL296UH045XE36B 826076914ACXS024-230 TXV 24000 16 13 CX35-36B EL296UH045XV36B 826077214ACXS024-230 TXV 24000 16 13 CX35-36B EL296UH070XE36B 826077114ACXS024-230 TXV 24000 16 13 CX35-36B EL296UH070XV36B 826076114ACXS024-230 TXV 24000 16 13.5 CX35-36B SL280UH090V36B 8260774NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 48

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS024-230 TXV 24000 16 13 CX35-36B SL280UH090V48B 826077614ACXS024-230 TXV 24000 16 13 CX35-36B SL280UH090XV48B 826077814ACXS024-230 TXV 24000 16 13 CX35-36B SLP98UH070XV36B 826076314ACXS024-230 TXV 24000 14.5 12.5 CX35-36B 826075914ACXS024-230 TXV 23800 14.25 12.2 CX38-25B 1054755514ACXS030-230 RFC 27400 14 12 C35-24A 847106814ACXS030-230 RFC 27400 14 12 C35-24B 847106914ACXS030-230 RFC 28000 14 12.2 C35-30A 847103214ACXS030-230 RFC 28000 14 12.2 C35-30B 847103514ACXS030-230 RFC 28000 14 12.2 C35-36A 847103814ACXS030-230 RFC 28000 14 12.2 C35-36B 847104114ACXS030-230 RFC 27400 14 12.2 C35-48B 847104314ACXS030-230 RFC 27400 14 12.2 C35-48C 847104514ACXS030-230 RFC 27600 14 12 CH33-25A 762565314ACXS030-230 RFC 28000 14.25 12.2 CH33-31A 762568214ACXS030-230 RFC 28000 14.25 12.2 CH33-31B 762569214ACXS030-230 RFC 27600 14 12 CH33-36C 762574414ACXS030-230 RFC 28000 14 12.2 CH33-42B 762575414ACXS030-230 RFC 28000 14.5 12.5 CH33-43B 762575614ACXS030-230 RFC 27400 14 12 CH35-24A 1051453014ACXS030-230 RFC 27400 14 12 CH35-24B 1051453114ACXS030-230 RFC 28000 14 12.2 CH35-30A 1051453214ACXS030-230 RFC 28000 14 12.2 CH35-30B 1051453314ACXS030-230 RFC 28000 14 12.2 CH35-42B 1051453414ACXS030-230 RFC 27400 14 12.2 CH35-48B 1051453514ACXS030-230 RFC 27400 14 12.2 CH35-48C 1051453614ACXS030-230 RFC 27800 14 12 CR33-30/36A 762589114ACXS030-230 RFC 27800 14 12 CR33-30/36B 762589814ACXS030-230 RFC 27800 14 12 CR33-30/36C 762591914ACXS030-230 TXV 28000 15.1 12.5 C35-24A EL180UH045E36A 826088714ACXS030-230 TXV 28000 15.1 12.5 C35-24A EL180UH045XE36A 826088814ACXS030-230 TXV 28000 15.5 12.5 C35-24A SL280UH070V36A 826088314ACXS030-230 TXV 28000 15.5 12.5 C35-24A SL280UH070XV36A 826088514ACXS030-230 TXV 27600 14 12 C35-24A 826088214ACXS030-230 TXV 28000 15.5 12.5 C35-24B EL180UH070E36B 825975514ACXS030-230 TXV 28000 15.5 12.5 C35-24B EL180UH070XE36B 825975714ACXS030-230 TXV 27800 15.5 12.5 C35-24B EL180UH090E48B 825974614ACXS030-230 TXV 27800 15.5 12.5 C35-24B EL180UH090XE48B 825974714ACXS030-230 TXV 28000 15.1 12.5 C35-24B EL195UH045XE36B 825975914ACXS030-230 TXV 28000 15 12.5 C35-24B EL195UH070XE36B 825976214ACXS030-230 TXV 28000 15.1 12.5 C35-24B EL296UH045XE36B 825976014ACXS030-230 TXV 28000 15 12.5 C35-24B EL296UH070XE36B 825974914ACXS030-230 TXV 28000 15.1 12.5 C35-24B EL296UH070XV36B 825975114ACXS030-230 TXV 28000 15.5 12.5 C35-24B SL280UH090V36B 825975414ACXS030-230 TXV 28000 15.1 12.5 C35-24B SLP98UH070XV36B 825975214ACXS030-230 TXV 27600 14 12 C35-24B 825974414ACXS030-230 TXV 28000 15.1 12.5 C35-30/36A EL180UH045E36A 825979914ACXS030-230 TXV 28000 15.1 12.5 C35-30/36A EL180UH045XE36A 825979414ACXS030-230 TXV 28000 15.5 12.5 C35-30/36A SL280UH070V36A 8259795NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 49

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS030-230 TXV 28000 15.5 12.5 C35-30/36A SL280UH070XV36A 825979714ACXS030-230 TXV 27600 14 12 C35-30/36A 825979214ACXS030-230 TXV 28000 15.5 12.5 C35-30/36B EL180UH070E36B 825981714ACXS030-230 TXV 28000 15.5 12.5 C35-30/36B EL180UH070XE36B 825981814ACXS030-230 TXV 28000 15.5 12.5 C35-30/36B EL180UH090E48B 825982014ACXS030-230 TXV 28000 15.5 12.5 C35-30/36B EL180UH090XE48B 825980314ACXS030-230 TXV 28000 15.1 12.5 C35-30/36B EL195UH045XE36B 825980514ACXS030-230 TXV 28000 15.1 12.5 C35-30/36B EL195UH070XE36B 825980814ACXS030-230 TXV 28000 15.1 12.5 C35-30/36B EL296UH045XE36B 825980714ACXS030-230 TXV 27800 15.1 12.5 C35-30/36B EL296UH045XV36B 825980214ACXS030-230 TXV 28000 15.1 12.5 C35-30/36B EL296UH070XE36B 825981014ACXS030-230 TXV 28000 15.5 12.5 C35-30/36B EL296UH070XV36B 825981314ACXS030-230 TXV 28000 15.5 12.5 C35-30/36B SL280UH090V36B 825981514ACXS030-230 TXV 28000 15.5 12.5 C35-30/36B SLP98UH070XV36B 825981214ACXS030-230 TXV 27600 14 12 C35-30/36B 825980014ACXS030-230 TXV 28000 15.1 12.5 C35-30/36C EL195UH090XE48C 825982214ACXS030-230 TXV 28000 15.1 12.5 C35-30/36C EL296UH090XE48C 825982314ACXS030-230 TXV 28000 15.5 12.5 C35-30/36C EL296UH090XV36C 825982514ACXS030-230 TXV 28000 15.5 12.5 C35-30/36C SLP98UH090XV36C 825982614ACXS030-230 TXV 28000 15.5 12.5 C35-30A EL180UH045E36A 825976914ACXS030-230 TXV 28000 15.5 12.5 C35-30A EL180UH045XE36A 825977014ACXS030-230 TXV 28000 16 13 C35-30A SL280UH070V36A 825976614ACXS030-230 TXV 28000 16 13 C35-30A SL280UH070XV36A 825976714ACXS030-230 TXV 28000 14.25 12.2 C35-30A 825976414ACXS030-230 TXV 28000 16 13 C35-30B EL180UH070E36B 825979014ACXS030-230 TXV 28000 16 13 C35-30B EL180UH070XE36B 825977914ACXS030-230 TXV 28000 16 13 C35-30B EL180UH090E48B 825978014ACXS030-230 TXV 28000 16 13 C35-30B EL180UH090XE48B 825978214ACXS030-230 TXV 28000 15.5 12.5 C35-30B EL195UH045XE36B 825978414ACXS030-230 TXV 28000 15.1 12.5 C35-30B EL195UH070XE36B 825978714ACXS030-230 TXV 28000 15.5 12.5 C35-30B EL296UH045XE36B 825978514ACXS030-230 TXV 28000 15.1 12.5 C35-30B EL296UH070XE36B 825977414ACXS030-230 TXV 28000 16 13 C35-30B EL296UH070XV36B 825977514ACXS030-230 TXV 28000 16 13 C35-30B SL280UH090V36B 825978914ACXS030-230 TXV 28000 16 13 C35-30B SLP98UH070XV36B 825977714ACXS030-230 TXV 28000 14.25 12.2 C35-30B 825977214ACXS030-230 TXV 28000 16 13 C35-36A EL180UH045E36A 825983014ACXS030-230 TXV 28000 16 13 C35-36A EL180UH045XE36A 825983214ACXS030-230 TXV 28000 16 13 C35-36A SL280UH070V36A 825983414ACXS030-230 TXV 28000 16 13 C35-36A SL280UH070XV36A 825983614ACXS030-230 TXV 28000 14.25 12.2 C35-36A 825982814ACXS030-230 TXV 28000 16 13 C35-36B EL180UH070E36B 825985414ACXS030-230 TXV 28000 16 13 C35-36B EL180UH070XE36B 825985514ACXS030-230 TXV 28000 16 13 C35-36B EL180UH090E48B 825985714ACXS030-230 TXV 28000 16 13 C35-36B EL180UH090XE48B 825984214ACXS030-230 TXV 28000 15.5 12.5 C35-36B EL195UH045XE36B 825984414ACXS030-230 TXV 28000 15.5 12.5 C35-36B EL195UH070XE36B 825984714ACXS030-230 TXV 28000 15.5 12.5 C35-36B EL296UH045XE36B 825984514ACXS030-230 TXV 28000 15.5 12.5 C35-36B EL296UH045XV36B 8259850NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 50

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS030-230 TXV 28000 15.5 12.5 C35-36B EL296UH070XE36B 825984914ACXS030-230 TXV 28000 16 13 C35-36B EL296UH070XV36B 825983914ACXS030-230 TXV 28000 16 13 C35-36B SL280UH090V36B 825985214ACXS030-230 TXV 28000 16 13 C35-36B SLP98UH070XV36B 825984114ACXS030-230 TXV 28000 14.5 12.2 C35-36B 825983714ACXS030-230 TXV 28000 16 13 C35-48B EL180UH070E36B 825987514ACXS030-230 TXV 28000 16 13 C35-48B EL180UH070XE36B 825987714ACXS030-230 TXV 28000 16 13 C35-48B EL180UH090E48B 825987814ACXS030-230 TXV 28000 16 13 C35-48B EL180UH090XE48B 825986414ACXS030-230 TXV 28000 15.5 12.5 C35-48B EL195UH045XE36B 825986514ACXS030-230 TXV 28000 15.5 12.5 C35-48B EL195UH070XE36B 825986914ACXS030-230 TXV 28000 15.5 12.5 C35-48B EL296UH045XE36B 825986714ACXS030-230 TXV 28000 15.5 12.5 C35-48B EL296UH045XV36B 825987214ACXS030-230 TXV 28000 15.5 12.5 C35-48B EL296UH070XE36B 825987014ACXS030-230 TXV 28000 16 13 C35-48B EL296UH070XV36B 825986014ACXS030-230 TXV 28000 16 13 C35-48B SL280UH090V36B 825987314ACXS030-230 TXV 28000 16 13 C35-48B SLP98UH070XV36B 825986214ACXS030-230 TXV 28000 14.5 12.2 C35-48B 825985914ACXS030-230 TXV 28000 16 13 C35-48C EL195UH090XE48C 825988514ACXS030-230 TXV 28000 16 13 C35-48C EL296UH090XE48C 825988714ACXS030-230 TXV 28000 16 13 C35-48C EL296UH090XV36C 825988814ACXS030-230 TXV 28000 16 13 C35-48C EL296UH090XV48C 825988214ACXS030-230 TXV 28000 16 13 C35-48C SLP98UH090XV36C 825989014ACXS030-230 TXV 28000 16 13 C35-48C SLP98UH090XV48C 825988314ACXS030-230 TXV 28000 14.5 12.2 C35-48C 825988014ACXS030-230 TXV 28600 16 13 CBA27UHE-030 1025939014ACXS030-230 TXV 28600 16 13 CBA27UHE-036 1025939114ACXS030-230 TXV 27800 14 12 CBX25UH-030 762559814ACXS030-230 TXV 28000 14.5 12.2 CBX25UH-036 762560014ACXS030-230 TXV 28000 15.1 12.5 CBX25UHV-030 762560214ACXS030-230 TXV 28000 15.1 12.5 CBX25UHV-036 762560314ACXS030-230 TXV 28000 16 13 CBX27UH-030 762560514ACXS030-230 TXV 28000 16 13 CBX27UH-036 762560614ACXS030-230 TXV 28000 15 12.5 CBX32M-030 762560814ACXS030-230 TXV 28000 15 12.5 CBX32M-036 762561014ACXS030-230 TXV 28000 14.5 12.5 CBX32MV-024/030 762561114ACXS030-230 TXV 28000 15.1 12.5 CBX32MV-036 762561314ACXS030-230 TXV 28000 15.1 12.5 CBX40UHV-030 762561414ACXS030-230 TXV 28000 15.5 12.5 CBX40UHV-036 778314014ACXS030-230 TXV 26800 15 12.5 CH23-31 EL180UH070E36B 762823914ACXS030-230 TXV 26800 15 12.5 CH23-31 EL180UH070XE36B 778314114ACXS030-230 TXV 26800 15 12.5 CH23-31 EL180UH090E48B 778322714ACXS030-230 TXV 26800 15 12.5 CH23-31 EL180UH090XE48B 762853514ACXS030-230 TXV 26600 14.25 12.2 CH23-31 EL195UH045XE36B 778322614ACXS030-230 TXV 26600 14.25 14.6 CH23-31 EL195UH070XE36B 778322814ACXS030-230 TXV 26600 14.25 12.2 CH23-31 EL296UH045XE36B 762853214ACXS030-230 TXV 26600 14.5 12.2 CH23-31 EL296UH045XV36B 762561614ACXS030-230 TXV 26600 14.25 14.6 CH23-31 EL296UH070XE36B 762853814ACXS030-230 TXV 26800 14.5 12.5 CH23-31 EL296UH070XV36B 7625619NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 51

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS030-230 TXV 26800 15.1 12.5 CH23-31 SL280UH090V36B 762561814ACXS030-230 TXV 26800 14.5 12.5 CH23-31 SLP98UH070XV36B 762562114ACXS030-230 TXV 28000 15.5 12.5 CH23-41 EL180UH045E36A 762562614ACXS030-230 TXV 28000 15.5 12.5 CH23-41 EL180UH045XE36A 762562714ACXS030-230 TXV 28000 15.5 12.5 CH23-41 EL180UH070E36B 762562914ACXS030-230 TXV 28000 15.5 12.5 CH23-41 EL180UH070XE36B 762563114ACXS030-230 TXV 28000 16 13 CH23-41 EL180UH090E48B 762563214ACXS030-230 TXV 28000 16 13 CH23-41 EL180UH090XE48B 762563414ACXS030-230 TXV 28000 15.1 12.5 CH23-41 EL195UH045XE36B 762563514ACXS030-230 TXV 28000 15.1 12.5 CH23-41 EL195UH070XE36B 762563914ACXS030-230 TXV 28000 15.1 12.5 CH23-41 EL296UH045XE36B 762563714ACXS030-230 TXV 28000 15.1 12.5 CH23-41 EL296UH045XV36B 762564214ACXS030-230 TXV 28000 15.1 12.5 CH23-41 EL296UH070XE36B 762564014ACXS030-230 TXV 28000 15.5 12.5 CH23-41 EL296UH070XV36B 762564314ACXS030-230 TXV 28000 16 13 CH23-41 SL280UH090V36B 762562414ACXS030-230 TXV 28000 15.5 12.5 CH23-41 SLP98UH070XV36B 762564514ACXS030-230 TXV 27800 14 12 CH23-41 762562314ACXS030-230 TXV 27400 15 12.5 CH33-19 EL180UH045E36A 762564714ACXS030-230 TXV 27400 15 12.5 CH33-19 EL180UH045XE36A 762564814ACXS030-230 TXV 27600 15.1 12.5 CH33-19 SL280UH070V36A 762565014ACXS030-230 TXV 27600 15.1 12.5 CH33-19 SL280UH070XV36A 762565114ACXS030-230 TXV 27400 15 12.5 CH33-24/30 EL180UH045E36A 762824514ACXS030-230 TXV 27400 15 12.5 CH33-24/30 EL180UH045XE36A 778314314ACXS030-230 TXV 27400 15 12.5 CH33-24/30 SL280UH070V36A 762824214ACXS030-230 TXV 27400 15 12.5 CH33-24/30 SL280UH070XV36A 778314214ACXS030-230 TXV 28000 15.1 12.5 CH33-25A EL180UH045E36A 762566014ACXS030-230 TXV 28000 15.1 12.5 CH33-25A EL180UH045XE36A 762566114ACXS030-230 TXV 28000 15.5 12.5 CH33-25A SL280UH070V36A 762565714ACXS030-230 TXV 28000 15.5 12.5 CH33-25A SL280UH070XV36A 762565814ACXS030-230 TXV 27800 14 12 CH33-25A 762565514ACXS030-230 TXV 28000 15.5 12.5 CH33-25B EL180UH070E36B 762566614ACXS030-230 TXV 28000 15.5 12.5 CH33-25B EL180UH070XE36B 762566814ACXS030-230 TXV 28000 15.5 12.5 CH33-25B EL180UH090E48B 762566914ACXS030-230 TXV 28000 15.5 12.5 CH33-25B EL180UH090XE48B 762567114ACXS030-230 TXV 28000 15.1 12.5 CH33-25B EL195UH045XE36B 762567314ACXS030-230 TXV 28000 15.1 12.5 CH33-25B EL195UH070XE36B 762567614ACXS030-230 TXV 28000 15.1 12.5 CH33-25B EL296UH045XE36B 762824814ACXS030-230 TXV 28000 15.1 12.5 CH33-25B EL296UH045XV36B 762567414ACXS030-230 TXV 28000 15.1 12.5 CH33-25B EL296UH070XE36B 762567714ACXS030-230 TXV 28000 15.5 12.5 CH33-25B EL296UH070XV36B 762567914ACXS030-230 TXV 28000 16 13 CH33-25B SL280UH090V36B 915035914ACXS030-230 TXV 28000 15.5 12.5 CH33-25B SLP98UH070XV36B 762568114ACXS030-230 TXV 27600 14 12 CH33-25B 762566314ACXS030-230 TXV 28000 15.5 12.5 CH33-31A EL180UH045E36A 762568914ACXS030-230 TXV 28000 15.5 12.5 CH33-31A EL180UH045XE36A 762569114ACXS030-230 TXV 28000 15.5 12.5 CH33-31A SL280UH070V36A 762568614ACXS030-230 TXV 28000 15.5 12.5 CH33-31A SL280UH070XV36A 762568714ACXS030-230 TXV 28000 14.25 12.2 CH33-31A 762568414ACXS030-230 TXV 28000 16 13 CH33-31B EL180UH070E36B 7625697NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 52

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS030-230 TXV 28000 16 13 CH33-31B EL180UH070XE36B 762569914ACXS030-230 TXV 28000 16 13 CH33-31B EL180UH090E48B 762570014ACXS030-230 TXV 28000 16 13 CH33-31B EL180UH090XE48B 762570214ACXS030-230 TXV 28000 15.5 12.5 CH33-31B EL195UH045XE36B 762570414ACXS030-230 TXV 28000 15.5 12.5 CH33-31B EL195UH070XE36B 762570714ACXS030-230 TXV 28000 15.5 12.5 CH33-31B EL296UH045XE36B 762570514ACXS030-230 TXV 28000 15.5 12.5 CH33-31B EL296UH045XV36B 762571014ACXS030-230 TXV 28000 15.5 12.5 CH33-31B EL296UH070XE36B 762570814ACXS030-230 TXV 28000 16 13 CH33-31B EL296UH070XV36B 762571214ACXS030-230 TXV 28000 16 13 CH33-31B SL280UH090V36B 762569614ACXS030-230 TXV 28000 16 13 CH33-31B SLP98UH070XV36B 762571314ACXS030-230 TXV 28000 14.5 12.2 CH33-31B 762569414ACXS030-230 TXV 27800 15.1 12.5 CH33-36A EL180UH045E36A 762571714ACXS030-230 TXV 27800 15.1 12.5 CH33-36A EL180UH045XE36A 762571814ACXS030-230 TXV 28000 15.1 12.5 CH33-36A SL280UH070V36A 762572014ACXS030-230 TXV 28000 15.1 12.5 CH33-36A SL280UH070XV36A 762572114ACXS030-230 TXV 27400 14 11.5 CH33-36A 762571514ACXS030-230 TXV 28000 15.5 12.5 CH33-36B EL180UH070E36B 762572814ACXS030-230 TXV 28000 15.5 12.5 CH33-36B EL180UH070XE36B 762573014ACXS030-230 TXV 28000 15.5 12.5 CH33-36B EL180UH090E48B 762573114ACXS030-230 TXV 28000 15.5 12.5 CH33-36B EL180UH090XE48B 762573314ACXS030-230 TXV 28000 15.1 12.5 CH33-36B EL195UH045XE36B 762573414ACXS030-230 TXV 28000 15.1 12.5 CH33-36B EL195UH070XE36B 762573814ACXS030-230 TXV 28000 15.1 12.5 CH33-36B EL296UH045XE36B 762573614ACXS030-230 TXV 27800 15.1 12.5 CH33-36B EL296UH045XV36B 762572514ACXS030-230 TXV 28000 15.1 12.5 CH33-36B EL296UH070XE36B 762573914ACXS030-230 TXV 28000 15.5 12.5 CH33-36B SL280UH090V36B 762572614ACXS030-230 TXV 28000 15.5 12.5 CH33-36B SLP98UH070XV36B 762574314ACXS030-230 TXV 27600 14 11.5 CH33-36B 762572314ACXS030-230 TXV 28000 15.1 12.5 CH33-36C EL195UH090XE48C 762574814ACXS030-230 TXV 28000 15.1 12.5 CH33-36C EL296UH090XE48C 762574914ACXS030-230 TXV 28000 15.5 12.5 CH33-36C EL296UH090XV36C 762575114ACXS030-230 TXV 28000 15.5 12.5 CH33-36C SLP98UH090XV36C 762575214ACXS030-230 TXV 27800 14 12 CH33-36C 762574614ACXS030-230 TXV 28000 14.25 12.2 CH33-42 778314414ACXS030-230 TXV 28000 16 13 CH33-42B EL180UH070E36B 778314514ACXS030-230 TXV 28000 16 13 CH33-42B EL180UH070XE36B 762825514ACXS030-230 TXV 28000 16 13 CH33-42B EL180UH090E48B 778314614ACXS030-230 TXV 28000 16 13 CH33-42B EL180UH090XE48B 762825814ACXS030-230 TXV 28000 15.5 12.5 CH33-42B EL195UH045XE36B 778314714ACXS030-230 TXV 28000 15.5 12.5 CH33-42B EL195UH070XE36B 778314814ACXS030-230 TXV 28000 15.5 12.5 CH33-42B EL296UH045XE36B 762826114ACXS030-230 TXV 28000 15.5 12.5 CH33-42B EL296UH045XV36B 778314914ACXS030-230 TXV 28000 15.5 12.5 CH33-42B EL296UH070XE36B 762826414ACXS030-230 TXV 28000 15.5 12.5 CH33-42B EL296UH070XV36B 762826714ACXS030-230 TXV 28000 15.5 12.5 CH33-42B SLP98UH070XV36B 778315014ACXS030-230 TXV 28000 16 13 CH33-43B EL180UH070E36B 762576114ACXS030-230 TXV 28000 16 13 CH33-43B EL180UH070XE36B 762576214ACXS030-230 TXV 28000 16 13 CH33-43B EL180UH090E48B 7625764NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 53

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS030-230 TXV 28000 16 13 CH33-43B EL180UH090XE48B 762576614ACXS030-230 TXV 28000 16 13 CH33-43B EL195UH045XE36B 762576714ACXS030-230 TXV 28000 16 13 CH33-43B EL195UH070XE36B 762577014ACXS030-230 TXV 28000 16 13 CH33-43B EL296UH045XE36B 762576914ACXS030-230 TXV 28000 16 13 CH33-43B EL296UH045XV36B 762577414ACXS030-230 TXV 28000 16 13 CH33-43B EL296UH070XE36B 762577214ACXS030-230 TXV 28000 16 13 CH33-43B EL296UH070XV36B 762577514ACXS030-230 TXV 28000 16 13 CH33-43B SL280UH090V36B 762575914ACXS030-230 TXV 28000 16 13 CH33-43B SLP98UH070XV36B 762577714ACXS030-230 TXV 28000 14.5 12.5 CH33-43B 762575814ACXS030-230 TXV 28000 16 13 CH33-43C EL195UH090XE48C 762578014ACXS030-230 TXV 28000 16 13 CH33-43C EL296UH090XE48C 762578214ACXS030-230 TXV 28000 16 13 CH33-43C EL296UH090XV36C 762578314ACXS030-230 TXV 28000 16 13 CH33-43C SLP98UH090XV36C 762578514ACXS030-230 TXV 28000 14.5 12.2 CH33-43C 762577914ACXS030-230 TXV 27800 14 12 CH35-24A 762993814ACXS030-230 TXV 28000 15.5 12.5 CH35-24B EL180UH070E36B 762582514ACXS030-230 TXV 28000 15.5 12.5 CH35-30A EL180UH045E36A 762579014ACXS030-230 TXV 28000 15.5 12.5 CH35-30A EL180UH045XE36A 762579114ACXS030-230 TXV 28000 15.5 12.5 CH35-30A SL280UH070V36A 762578714ACXS030-230 TXV 28000 15.5 12.5 CH35-30A SL280UH070XV36A 762578814ACXS030-230 TXV 28000 14.25 12.2 CH35-30A 778366514ACXS030-230 TXV 28000 16 13 CH35-30B EL180UH070E36B 762579614ACXS030-230 TXV 28000 16 13 CH35-30B EL180UH070XE36B 762579814ACXS030-230 TXV 28000 16 13 CH35-30B EL180UH090E48B 762579914ACXS030-230 TXV 28000 16 13 CH35-30B EL180UH090XE48B 762580114ACXS030-230 TXV 28000 15.5 12.5 CH35-30B EL195UH045XE36B 762580314ACXS030-230 TXV 28000 15.5 12.5 CH35-30B EL195UH070XE36B 762580614ACXS030-230 TXV 28000 15.5 12.5 CH35-30B EL296UH045XE36B 762580914ACXS030-230 TXV 28000 15.5 12.5 CH35-30B EL296UH045XV36B 762580414ACXS030-230 TXV 28000 15.5 12.5 CH35-30B EL296UH070XE36B 762580714ACXS030-230 TXV 28000 16 13 CH35-30B EL296UH070XV36B 762581114ACXS030-230 TXV 28000 16 13 CH35-30B SL280UH090V36B 762579514ACXS030-230 TXV 28000 16 13 CH35-30B SLP98UH070XV36B 762581214ACXS030-230 TXV 28000 14.5 12.2 CH35-30B 762579314ACXS030-230 TXV 28000 15.1 12.5 CH35-36A EL180UH045E36A 762581914ACXS030-230 TXV 28000 15.1 12.5 CH35-36A EL180UH045XE36A 762582014ACXS030-230 TXV 28000 15.1 12.5 CH35-36A SL280UH070V36A 762581614ACXS030-230 TXV 28000 15.1 12.5 CH35-36A SL280UH070XV36A 762581714ACXS030-230 TXV 27600 14 12 CH35-36A 762581414ACXS030-230 TXV 28000 15.5 12.5 CH35-36B EL180UH070E36B 762582714ACXS030-230 TXV 28000 15.5 12.5 CH35-36B EL180UH090E48B 762582914ACXS030-230 TXV 28000 15.5 12.5 CH35-36B EL180UH090XE48B 762583014ACXS030-230 TXV 28000 15.1 12.5 CH35-36B EL195UH045XE36B 762583214ACXS030-230 TXV 28000 15.1 12.5 CH35-36B EL195UH070XE36B 762583614ACXS030-230 TXV 28000 15.1 12.5 CH35-36B EL296UH045XE36B 762583414ACXS030-230 TXV 28000 15.1 12.5 CH35-36B EL296UH045XV36B 762583914ACXS030-230 TXV 28000 15.1 12.5 CH35-36B EL296UH070XE36B 762583714ACXS030-230 TXV 28000 15.5 12.5 CH35-36B EL296UH070XV36B 7625841NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 54

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS030-230 TXV 28000 16 13 CH35-36B SL280UH090V36B 762582414ACXS030-230 TXV 28000 15.5 12.5 CH35-36B SLP98UH070XV36B 762584214ACXS030-230 TXV 27600 14 12 CH35-36B 762582214ACXS030-230 TXV 28000 15.1 12.5 CH35-36C EL195UH090XE48C 762584614ACXS030-230 TXV 28000 15.1 12.5 CH35-36C EL296UH090XE48C 762584814ACXS030-230 TXV 28000 16 13 CH35-36C EL296UH090XV36C 762584914ACXS030-230 TXV 28000 16 13 CH35-36C SLP98UH090XV36C 762585114ACXS030-230 TXV 27800 14.25 12 CH35-36C 762584414ACXS030-230 TXV 28000 16 13 CH35-42B EL180UH070E36B 762585614ACXS030-230 TXV 28000 16 13 CH35-42B EL180UH070XE36B 762585814ACXS030-230 TXV 28000 16 13 CH35-42B EL180UH090E48B 762586014ACXS030-230 TXV 28000 16 13 CH35-42B EL180UH090XE48B 762586114ACXS030-230 TXV 28000 16 13 CH35-42B EL195UH045XE36B 762586314ACXS030-230 TXV 28000 16 13 CH35-42B EL195UH070XE36B 762586814ACXS030-230 TXV 28000 16 13 CH35-42B EL296UH045XE36B 762587014ACXS030-230 TXV 28000 16 13 CH35-42B EL296UH045XV36B 762586514ACXS030-230 TXV 28000 16 13 CH35-42B EL296UH070XE36B 762586714ACXS030-230 TXV 28000 16 13 CH35-42B EL296UH070XV36B 762587214ACXS030-230 TXV 28000 16 13 CH35-42B SL280UH090V36B 762585514ACXS030-230 TXV 28000 16 13 CH35-42B SLP98UH070XV36B 762587314ACXS030-230 TXV 28000 14.5 12.5 CH35-42B 762585314ACXS030-230 TXV 28000 15.5 12.5 CH35-42C EL195UH090XE48C 762587714ACXS030-230 TXV 28000 15.5 12.5 CH35-42C EL296UH090XE48C 762587914ACXS030-230 TXV 28000 16 13 CH35-42C EL296UH090XV36C 762588014ACXS030-230 TXV 28000 16 13 CH35-42C SLP98UH090XV36C 762588214ACXS030-230 TXV 28000 14.5 12.2 CH35-42C 762587514ACXS030-230 TXV 26800 14.5 12.2 CR33-24A EL180DF045E36A 762588414ACXS030-230 TXV 26800 14.25 12.2 CR33-24B EL180DF070E36B 762588914ACXS030-230 TXV 26600 14 12 CR33-24B EL180DF090E48B 778322914ACXS030-230 TXV 26600 14.25 12.2 CR33-24B EL296DF045XV36B 778315114ACXS030-230 TXV 26600 14 12 CR33-24B EL296DF070XV48B 762588714ACXS030-230 TXV 26600 14.25 12.2 CR33-24B SL280DF090V48B 762588514ACXS030-230 TXV 26600 14.25 12.2 CR33-24B SLP98DF070XV36B 762827014ACXS030-230 TXV 28000 15.1 12.5 CR33-30/36A EL180DF045E36A 762589614ACXS030-230 TXV 28000 15.5 12.5 CR33-30/36A SL280DF070V36A 762589514ACXS030-230 TXV 28000 14.25 12 CR33-30/36A 762589314ACXS030-230 TXV 28000 15.5 12.5 CR33-30/36B EL180DF070E36B 762590414ACXS030-230 TXV 28000 15.5 12.5 CR33-30/36B EL180DF090E48B 762590514ACXS030-230 TXV 28000 15.1 12.5 CR33-30/36B EL195DF045XE36B 762590714ACXS030-230 TXV 28000 15.5 12.5 CR33-30/36B EL195DF070XE48B 762591114ACXS030-230 TXV 28000 15.1 12.5 CR33-30/36B EL296DF045XE36B 762590914ACXS030-230 TXV 28000 15.5 12.5 CR33-30/36B EL296DF045XV36B 762591414ACXS030-230 TXV 28000 15.5 12.5 CR33-30/36B EL296DF070XE48B 762591214ACXS030-230 TXV 28000 15.1 12.5 CR33-30/36B EL296DF070XV48B 762591614ACXS030-230 TXV 28000 15.5 12.5 CR33-30/36B SL280DF090V48B 762590214ACXS030-230 TXV 28000 15.5 12.5 CR33-30/36B SLP98DF070XV36B 762591814ACXS030-230 TXV 28000 14.25 12 CR33-30/36B 762590014ACXS030-230 TXV 28000 16 13 CR33-30/36C SLP98DF090XV36C 762592314ACXS030-230 TXV 28000 14.25 12 CR33-30/36C 7625921NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 55

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS030-230 TXV 28000 15.1 12.5 CX35-24A EL180UH045E36A 825989814ACXS030-230 TXV 28000 15.1 12.5 CX35-24A EL180UH045XE36A 825989314ACXS030-230 TXV 28000 15.5 12.5 CX35-24A SL280UH070V36A 825989514ACXS030-230 TXV 28000 15.5 12.5 CX35-24A SL280UH070XV36A 825989714ACXS030-230 TXV 27600 14 12 CX35-24A 825989214ACXS030-230 TXV 28000 15.5 12.5 CX35-24B EL180UH070E36B 825991814ACXS030-230 TXV 28000 15.5 12.5 CX35-24B EL180UH070XE36B 825992014ACXS030-230 TXV 27800 15.5 12.5 CX35-24B EL180UH090E48B 825991314ACXS030-230 TXV 27800 15.5 12.5 CX35-24B EL180UH090XE48B 825991514ACXS030-230 TXV 28000 15.1 12.5 CX35-24B EL195UH045XE36B 825990314ACXS030-230 TXV 28000 15 12.5 CX35-24B EL195UH070XE36B 825990714ACXS030-230 TXV 28000 15.1 12.5 CX35-24B EL296UH045XE36B 825990514ACXS030-230 TXV 28000 15.1 12.5 CX35-24B EL296UH045XV36B 825991014ACXS030-230 TXV 28000 15 12.5 CX35-24B EL296UH070XE36B 825990814ACXS030-230 TXV 28000 15.1 12.5 CX35-24B EL296UH070XV36B 825991214ACXS030-230 TXV 28000 15.5 12.5 CX35-24B SL280UH090V36B 825991614ACXS030-230 TXV 28000 15.1 12.5 CX35-24B SLP98UH070XV36B 825990214ACXS030-230 TXV 27600 14 12 CX35-24B 825990014ACXS030-230 TXV 28000 15.1 12.5 CX35-30/36A EL180UH045E36A 825995414ACXS030-230 TXV 28000 15.1 12.5 CX35-30/36A EL180UH045XE36A 825995814ACXS030-230 TXV 28000 15.5 12.5 CX35-30/36A SL280UH070V36A 825995314ACXS030-230 TXV 28000 15.5 12.5 CX35-30/36A SL280UH070XV36A 825995614ACXS030-230 TXV 27600 14 12 CX35-30/36A 825995114ACXS030-230 TXV 28000 15.5 12.5 CX35-30/36B EL180UH070E36B 825997714ACXS030-230 TXV 28000 15.5 12.5 CX35-30/36B EL180UH070XE36B 825996114ACXS030-230 TXV 28000 15.5 12.5 CX35-30/36B EL180UH090E48B 825997914ACXS030-230 TXV 28000 15.5 12.5 CX35-30/36B EL180UH090XE48B 825996314ACXS030-230 TXV 28000 15.1 12.5 CX35-30/36B EL195UH045XE36B 825997114ACXS030-230 TXV 28000 15.1 12.5 CX35-30/36B EL195UH070XE36B 825997214ACXS030-230 TXV 28000 15.1 12.5 CX35-30/36B EL296UH045XE36B 825996414ACXS030-230 TXV 27800 15.1 12.5 CX35-30/36B EL296UH045XV36B 825997614ACXS030-230 TXV 28000 15.1 12.5 CX35-30/36B EL296UH070XE36B 825996614ACXS030-230 TXV 28000 15.5 12.5 CX35-30/36B EL296UH070XV36B 825997414ACXS030-230 TXV 28000 15.5 12.5 CX35-30/36B SL280UH090V36B 825996914ACXS030-230 TXV 28000 15.5 12.5 CX35-30/36B SLP98UH070XV36B 825996814ACXS030-230 TXV 27600 14 12 CX35-30/36B 825995914ACXS030-230 TXV 28000 15.1 12.5 CX35-30/36C EL195UH090XE48C 825998414ACXS030-230 TXV 28000 15.1 12.5 CX35-30/36C EL296UH090XE48C 825998214ACXS030-230 TXV 28000 15.5 12.5 CX35-30/36C EL296UH090XV36C 825998614ACXS030-230 TXV 28000 15.5 12.5 CX35-30/36C SLP98UH090XV36C 825998114ACXS030-230 TXV 28000 15.5 12.5 CX35-30A EL180UH045E36A 825992514ACXS030-230 TXV 28000 15.5 12.5 CX35-30A EL180UH045XE36A 825992614ACXS030-230 TXV 28000 16 13 CX35-30A SL280UH070V36A 825992314ACXS030-230 TXV 28000 16 13 CX35-30A SL280UH070XV36A 825992814ACXS030-230 TXV 28000 14.25 12.2 CX35-30A 825992114ACXS030-230 TXV 28000 16 13 CX35-30B EL180UH070E36B 825993814ACXS030-230 TXV 28000 16 13 CX35-30B EL180UH070XE36B 825994514ACXS030-230 TXV 28000 16 13 CX35-30B EL180UH090E48B 825994014ACXS030-230 TXV 28000 16 13 CX35-30B EL180UH090XE48B 8259946NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 56

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS030-230 TXV 28000 15.5 12.5 CX35-30B EL195UH045XE36B 825993314ACXS030-230 TXV 28000 15.1 12.5 CX35-30B EL195UH070XE36B 825993514ACXS030-230 TXV 28000 15.5 12.5 CX35-30B EL296UH045XE36B 825994814ACXS030-230 TXV 28000 15.5 12.5 CX35-30B EL296UH045XV36B 825993614ACXS030-230 TXV 28000 15.1 12.5 CX35-30B EL296UH070XE36B 825994914ACXS030-230 TXV 28000 16 13 CX35-30B EL296UH070XV36B 825994114ACXS030-230 TXV 28000 16 13 CX35-30B SL280UH090V36B 825994314ACXS030-230 TXV 28000 16 13 CX35-30B SLP98UH070XV36B 825993114ACXS030-230 TXV 28000 14.25 12.2 CX35-30B 825993014ACXS030-230 TXV 28000 16 13 CX35-36A EL180UH045E36A 825999114ACXS030-230 TXV 28000 16 13 CX35-36A EL180UH045XE36A 825999214ACXS030-230 TXV 28000 16 13 CX35-36A SL280UH070V36A 825998914ACXS030-230 TXV 28000 16 13 CX35-36A SL280UH070XV36A 825999414ACXS030-230 TXV 28000 14.5 12.2 CX35-36A 825998714ACXS030-230 TXV 28000 16 13 CX35-36B EL180UH070E36B 826000214ACXS030-230 TXV 28000 16 13 CX35-36B EL180UH070XE36B 826001114ACXS030-230 TXV 28000 16 13 CX35-36B EL180UH090E48B 826000414ACXS030-230 TXV 28000 16 13 CX35-36B EL180UH090XE48B 826001214ACXS030-230 TXV 28000 15.5 12.5 CX35-36B EL195UH045XE36B 826000614ACXS030-230 TXV 28000 15.5 12.5 CX35-36B EL195UH070XE36B 825999814ACXS030-230 TXV 28000 15.5 12.5 CX35-36B EL296UH045XE36B 826001414ACXS030-230 TXV 28000 15.5 12.5 CX35-36B EL296UH045XV36B 825999914ACXS030-230 TXV 28000 15.5 12.5 CX35-36B EL296UH070XE36B 826001614ACXS030-230 TXV 28000 16 13 CX35-36B EL296UH070XV36B 826000714ACXS030-230 TXV 28000 16 13 CX35-36B SL280UH090V36B 826000914ACXS030-230 TXV 28000 16 13 CX35-36B SLP98UH070XV36B 826000114ACXS030-230 TXV 28000 14.5 12.2 CX35-36B 825999614ACXS030-230 TXV 28000 16 13 CX35-48B EL180UH070E36B 826003114ACXS030-230 TXV 28000 16 13 CX35-48B EL180UH070XE36B 826002614ACXS030-230 TXV 28000 16 13 CX35-48B EL180UH090E48B 826003214ACXS030-230 TXV 28000 16 13 CX35-48B EL180UH090XE48B 826002714ACXS030-230 TXV 28000 15.5 12.5 CX35-48B EL195UH045XE36B 826003414ACXS030-230 TXV 28000 15.5 12.5 CX35-48B EL195UH070XE36B 826003614ACXS030-230 TXV 28000 15.5 12.5 CX35-48B EL296UH045XE36B 826001914ACXS030-230 TXV 28000 15.5 12.5 CX35-48B EL296UH045XV36B 826003814ACXS030-230 TXV 28000 15.5 12.5 CX35-48B EL296UH070XE36B 826002114ACXS030-230 TXV 28000 16 13 CX35-48B EL296UH070XV36B 826002214ACXS030-230 TXV 28000 16 13 CX35-48B SL280UH090V36B 826002414ACXS030-230 TXV 28000 16 13 CX35-48B SLP98UH070XV36B 826002914ACXS030-230 TXV 28000 14.5 12.2 CX35-48B 826001714ACXS030-230 TXV 28000 16 13 CX35-48C EL195UH090XE48C 826004714ACXS030-230 TXV 28000 16 13 CX35-48C EL296UH090XE48C 826004314ACXS030-230 TXV 28000 16 13 CX35-48C EL296UH090XV36C 826004914ACXS030-230 TXV 28000 16 13 CX35-48C EL296UH090XV48C 826004614ACXS030-230 TXV 28000 16 13 CX35-48C SLP98UH090XV36C 826004414ACXS030-230 TXV 28000 16 13 CX35-48C SLP98UH090XV48C 826004114ACXS030-230 TXV 28000 14.5 12.2 CX35-48C 826003914ACXS030-230 TXV 28000 14.25 12.2 CX38-31B 1054782614ACXS036-230 RFC 33600 14 12 C35-30A 8471033NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 57

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS036-230 RFC 33600 14 12 C35-30B 847103614ACXS036-230 RFC 34000 14 12 C35-36A 847103914ACXS036-230 RFC 34000 14 12 C35-36B 847104214ACXS036-230 RFC 34000 14 12 C35-48B 847104414ACXS036-230 RFC 34000 14 12 C35-48C 847104614ACXS036-230 RFC 34400 14 12.2 C35-49C 847104714ACXS036-230 RFC 34000 14 12.2 C35-50/60C 847104914ACXS036-230 RFC 33800 14 12.2 CH33-31B 778264814ACXS036-230 RFC 34600 14.5 12.2 CH33-43B 762652614ACXS036-230 RFC 34000 14.25 12.2 CH33-44/48B 762657814ACXS036-230 RFC 34000 14.25 12.2 CH33-48 762839614ACXS036-230 RFC 34600 14.5 12.2 CH33-49 778318614ACXS036-230 RFC 34400 14.25 12.2 CH33-50/60C 778271614ACXS036-230 RFC 33600 14 12 CH35-30A 1051453714ACXS036-230 RFC 33600 14 12 CH35-30B 1051453814ACXS036-230 RFC 32400 14 11.5 CH35-36A 1051453914ACXS036-230 RFC 32400 14 11.5 CH35-36B 1051454014ACXS036-230 RFC 34000 14 12 CH35-42B 1051454114ACXS036-230 RFC 34000 14 12 CH35-48B 1051454214ACXS036-230 RFC 34000 14 12 CH35-48C 1051454314ACXS036-230 RFC 34000 14 12.2 CH35-51C 1051454414ACXS036-230 RFC 33600 14 12 CR33-48B 762843814ACXS036-230 RFC 33800 14 12 CR33-48C 762845614ACXS036-230 TXV 33200 14.5 12.2 C35-30/36A EL180UH045E36A 825896014ACXS036-230 TXV 33200 14.5 12.2 C35-30/36A EL180UH045XE36A 825896414ACXS036-230 TXV 33400 15 12.2 C35-30/36A SL280UH070V36A 825895914ACXS036-230 TXV 33400 15 12.2 C35-30/36A SL280UH070XV36A 825896214ACXS036-230 TXV 33000 14 11.5 C35-30/36A 825895714ACXS036-230 TXV 33400 15.5 12.5 C35-30/36B EL180UH070E36B 825897014ACXS036-230 TXV 33400 15.5 12.5 C35-30/36B EL180UH070XE36B 825898014ACXS036-230 TXV 33400 15.1 12.5 C35-30/36B EL180UH090E48B 825897214ACXS036-230 TXV 33400 15.1 12.5 C35-30/36B EL180UH090XE48B 825898214ACXS036-230 TXV 33000 15 12.5 C35-30/36B EL195UH045XE36B 825897414ACXS036-230 TXV 33200 14.5 12 C35-30/36B EL195UH070XE36B 825897514ACXS036-230 TXV 33000 15 12.5 C35-30/36B EL296UH045XE36B 825898414ACXS036-230 TXV 33400 15 12.5 C35-30/36B EL296UH045XV36B 825897714ACXS036-230 TXV 33200 14.5 12 C35-30/36B EL296UH070XE36B 825898514ACXS036-230 TXV 33400 15 12.5 C35-30/36B EL296UH070XV36B 825898714ACXS036-230 TXV 33600 15.5 12.5 C35-30/36B SL280UH090V36B 825898914ACXS036-230 TXV 33600 15.5 12.5 C35-30/36B SL280UH090V48B 825896914ACXS036-230 TXV 33600 15.5 12.5 C35-30/36B SL280UH090XV48B 825897914ACXS036-230 TXV 33400 15 12.5 C35-30/36B SLP98UH070XV36B 825896714ACXS036-230 TXV 33000 14 11.5 C35-30/36B 825896614ACXS036-230 TXV 33600 15.1 12.5 C35-30/36C EL180UH090E60C 825899414ACXS036-230 TXV 33400 15.5 12.5 C35-30/36C EL180UH110E60C 825900414ACXS036-230 TXV 33400 15.5 12.5 C35-30/36C EL180UH110XE60C 825899514ACXS036-230 TXV 33200 15.1 12.5 C35-30/36C EL195UH090XE48C 825900514ACXS036-230 TXV 33600 15.1 12.5 C35-30/36C EL195UH110XE60C 825900714ACXS036-230 TXV 33200 15.1 12.5 C35-30/36C EL296UH090XE48C 8258997NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 58

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS036-230 TXV 33600 15.5 12.5 C35-30/36C EL296UH090XV36C 825900814ACXS036-230 TXV 33400 15.5 12.5 C35-30/36C EL296UH090XV48C 825901014ACXS036-230 TXV 33600 15.1 12.5 C35-30/36C EL296UH110XE60C 825899914ACXS036-230 TXV 33600 15.5 12.5 C35-30/36C EL296UH110XV48C 825901214ACXS036-230 TXV 33600 15.5 12.5 C35-30/36C SLP98UH090XV36C 825900014ACXS036-230 TXV 33400 15.5 12.5 C35-30/36C SLP98UH090XV48C 825899214ACXS036-230 TXV 33800 15.5 12.5 C35-30/36C SLP98UH110XV60C 825900214ACXS036-230 TXV 33000 14 11.5 C35-30/36C 825899014ACXS036-230 TXV 34200 15.1 12.5 C35-30A EL180UH045E36A 825893014ACXS036-230 TXV 34200 15.1 12.5 C35-30A EL180UH045XE36A 825892714ACXS036-230 TXV 34400 15.1 12.5 C35-30A SL280UH070V36A 825892914ACXS036-230 TXV 34400 15.1 12.5 C35-30A SL280UH070XV36A 825892614ACXS036-230 TXV 34000 14.5 12 C35-30A 825892414ACXS036-230 TXV 34400 15 12.5 C35-30B EL180UH070E36B 825894914ACXS036-230 TXV 34400 15 12.5 C35-30B EL180UH070XE36B 825893714ACXS036-230 TXV 34400 15.5 12.5 C35-30B EL180UH090E48B 825895014ACXS036-230 TXV 34400 15.5 12.5 C35-30B EL180UH090XE48B 825893914ACXS036-230 TXV 34000 14.5 12.2 C35-30B EL195UH045XE36B 825894014ACXS036-230 TXV 34000 15.1 12.5 C35-30B EL195UH070XE36B 825894214ACXS036-230 TXV 34000 14.5 12.2 C35-30B EL296UH045XE36B 825895214ACXS036-230 TXV 34200 15.1 12.5 C35-30B EL296UH045XV36B 825894414ACXS036-230 TXV 34000 15.1 12.5 C35-30B EL296UH070XE36B 825895414ACXS036-230 TXV 34200 15.1 12.5 C35-30B EL296UH070XV36B 825895514ACXS036-230 TXV 34400 15.5 12.5 C35-30B SL280UH090V36B 825893414ACXS036-230 TXV 34400 15.5 12.5 C35-30B SL280UH090V48B 825894714ACXS036-230 TXV 34400 15.5 12.5 C35-30B SL280UH090XV48B 825893514ACXS036-230 TXV 34200 15.1 12.5 C35-30B SLP98UH070XV36B 825894514ACXS036-230 TXV 34000 14.5 12 C35-30B 825893214ACXS036-230 TXV 34400 15.1 12.5 C35-36A EL180UH045E36A 826024614ACXS036-230 TXV 34400 15.1 12.5 C35-36A EL180UH045XE36A 826024914ACXS036-230 TXV 34600 15.5 12.5 C35-36A SL280UH070V36A 826024414ACXS036-230 TXV 34600 15.5 12.5 C35-36A SL280UH070XV36A 826024714ACXS036-230 TXV 34200 14.25 12.2 C35-36A 826024314ACXS036-230 TXV 34600 16 13 C35-36B EL180UH070E36B 826025614ACXS036-230 TXV 34600 16 13 C35-36B EL180UH070XE36B 826027414ACXS036-230 TXV 34600 16 13 C35-36B EL180UH090E48B 826026014ACXS036-230 TXV 34600 16 13 C35-36B EL180UH090XE48B 826025814ACXS036-230 TXV 34400 15 12.5 C35-36B EL195UH045XE36B 826026214ACXS036-230 TXV 34400 15 12.5 C35-36B EL195UH070XE36B 826026414ACXS036-230 TXV 34400 15 12.5 C35-36B EL296UH045XE36B 826025914ACXS036-230 TXV 34600 15.5 12.5 C35-36B EL296UH045XV36B 826025314ACXS036-230 TXV 34400 15 12.5 C35-36B EL296UH070XE36B 826026514ACXS036-230 TXV 34600 15.5 12.5 C35-36B EL296UH070XV36B 826026714ACXS036-230 TXV 34800 16 13 C35-36B SL280UH090V36B 826026914ACXS036-230 TXV 34800 16 13 C35-36B SL280UH090V48B 826027114ACXS036-230 TXV 34800 16 13 C35-36B SL280UH090XV48B 826027214ACXS036-230 TXV 34600 15.5 12.5 C35-36B SLP98UH070XV36B 826025414ACXS036-230 TXV 34200 14.25 12.2 C35-36B 826025114ACXS036-230 TXV 34800 16 13 C35-48B EL180UH070E36B 8259029NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 59

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS036-230 TXV 34800 16 13 C35-48B EL180UH070XE36B 825902614ACXS036-230 TXV 34800 16 13 C35-48B EL180UH090E48B 825903114ACXS036-230 TXV 34800 16 13 C35-48B EL180UH090XE48B 825902814ACXS036-230 TXV 34400 15 12.5 C35-48B EL195UH045XE36B 825903314ACXS036-230 TXV 34600 15.1 12.5 C35-48B EL195UH070XE36B 825903414ACXS036-230 TXV 34400 15 12.5 C35-48B EL296UH045XE36B 825901814ACXS036-230 TXV 34800 15.5 12.5 C35-48B EL296UH045XV36B 825903614ACXS036-230 TXV 34600 15.1 12.5 C35-48B EL296UH070XE36B 825902014ACXS036-230 TXV 34800 15.5 12.5 C35-48B EL296UH070XV36B 825902114ACXS036-230 TXV 34800 16 13 C35-48B SL280UH090V36B 825902314ACXS036-230 TXV 35000 16 13 C35-48B SL280UH090V48B 825903914ACXS036-230 TXV 35000 16 13 C35-48B SL280UH090XV48B 825902414ACXS036-230 TXV 34800 15.5 12.5 C35-48B SLP98UH070XV36B 825903814ACXS036-230 TXV 34400 14.5 12.2 C35-48B 825901614ACXS036-230 TXV 34800 16 13 C35-48C EL180UH090E60C 825906614ACXS036-230 TXV 34800 16 13 C35-48C EL180UH110E60C 825905614ACXS036-230 TXV 34800 16 13 C35-48C EL180UH110XE60C 825906714ACXS036-230 TXV 34600 15.5 12.5 C35-48C EL195UH090XE48C 825904314ACXS036-230 TXV 34800 16 13 C35-48C EL195UH110XE60C 825904414ACXS036-230 TXV 34600 15.5 12.5 C35-48C EL296UH090XE48C 825906914ACXS036-230 TXV 34800 16 13 C35-48C EL296UH090XV36C 825904614ACXS036-230 TXV 34800 16 13 C35-48C EL296UH090XV48C 825904814ACXS036-230 TXV 34600 16 13 C35-48C EL296UH110XE60C 825907114ACXS036-230 TXV 35000 16 13 C35-48C EL296UH110XV48C 825904914ACXS036-230 TXV 35200 16 13 C35-48C EL296UH110XV60C 825906114ACXS036-230 TXV 35400 16 13 C35-48C SL280UH090V60C 825906214ACXS036-230 TXV 35400 16 13 C35-48C SL280UH090XV60C 825905314ACXS036-230 TXV 35200 16 13 C35-48C SL280UH110V60C 825906414ACXS036-230 TXV 35200 16 13 C35-48C SL280UH110XV60C 825905414ACXS036-230 TXV 34800 16 13 C35-48C SLP98UH090XV36C 825905714ACXS036-230 TXV 34800 16 13 C35-48C SLP98UH090XV48C 825905914ACXS036-230 TXV 35200 16 13 C35-48C SLP98UH110XV60C 825905114ACXS036-230 TXV 34400 14.5 12.2 C35-48C 825904114ACXS036-230 TXV 35200 16 13 C35-49C EL180UH090E60C 825909414ACXS036-230 TXV 35000 16 13 C35-49C EL180UH110E60C 825908414ACXS036-230 TXV 35000 16 13 C35-49C EL180UH110XE60C 825909614ACXS036-230 TXV 34800 16 13 C35-49C EL195UH090XE48C 825908614ACXS036-230 TXV 35200 16 13 C35-49C EL195UH110XE60C 825908714ACXS036-230 TXV 34800 16 13 C35-49C EL296UH090XE48C 825909714ACXS036-230 TXV 35200 16 13 C35-49C EL296UH090XV36C 825907414ACXS036-230 TXV 35000 16 13 C35-49C EL296UH090XV48C 825907614ACXS036-230 TXV 35200 16 13 C35-49C EL296UH110XE60C 825909914ACXS036-230 TXV 35200 16 13 C35-49C EL296UH110XV48C 825907714ACXS036-230 TXV 35600 16 13 C35-49C EL296UH110XV60C 825909114ACXS036-230 TXV 35600 16 13 C35-49C SL280UH090V60C 825910214ACXS036-230 TXV 35600 16 13 C35-49C SL280UH090XV60C 825908114ACXS036-230 TXV 35400 16 13 C35-49C SL280UH110V60C 825909214ACXS036-230 TXV 35400 16 13 C35-49C SL280UH110XV60C 825908214ACXS036-230 TXV 35200 16 13 C35-49C SLP98UH090XV36C 8259101NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 60

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS036-230 TXV 35000 16 13 C35-49C SLP98UH090XV48C 825908914ACXS036-230 TXV 35600 16 13 C35-49C SLP98UH110XV60C 825907914ACXS036-230 TXV 34600 14.5 12.2 C35-49C 825907214ACXS036-230 TXV 34800 16 13 C35-50/60C EL180UH090E60C 825913214ACXS036-230 TXV 34800 16 13 C35-50/60C EL180UH110E60C 825911114ACXS036-230 TXV 34800 16 13 C35-50/60C EL180UH110XE60C 825913414ACXS036-230 TXV 34600 15.5 12.5 C35-50/60C EL195UH090XE48C 825911314ACXS036-230 TXV 34800 16 13 C35-50/60C EL195UH110XE60C 825911414ACXS036-230 TXV 34600 15.5 12.5 C35-50/60C EL296UH090XE48C 825912114ACXS036-230 TXV 34800 16 13 C35-50/60C EL296UH090XV36C 825911614ACXS036-230 TXV 34800 16 13 C35-50/60C EL296UH090XV48C 825911814ACXS036-230 TXV 34800 16 13 C35-50/60C EL296UH110XE60C 825912314ACXS036-230 TXV 35000 16 13 C35-50/60C EL296UH110XV48C 825910614ACXS036-230 TXV 35200 16 13 C35-50/60C EL296UH110XV60C 825912814ACXS036-230 TXV 35200 16 13 C35-50/60C SL280UH090V60C 825912914ACXS036-230 TXV 35200 16 13 C35-50/60C SL280UH090XV60C 825911914ACXS036-230 TXV 35000 16 13 C35-50/60C SL280UH110V60C 825913114ACXS036-230 TXV 35000 16 13 C35-50/60C SL280UH110XV60C 825910914ACXS036-230 TXV 34800 16 13 C35-50/60C SLP98UH090XV36C 825912414ACXS036-230 TXV 34800 16 13 C35-50/60C SLP98UH090XV48C 825912614ACXS036-230 TXV 35200 16 13 C35-50/60C SLP98UH110XV60C 825910814ACXS036-230 TXV 34200 14.5 12.2 C35-50/60C 825910414ACXS036-230 TXV 34600 16 13 CBA27UHE-036 1025948014ACXS036-230 TXV 35600 16 13 CBA27UHE-042 1025939214ACXS036-230 TXV 34200 14.5 12.2 CBX25UH-036 762634714ACXS036-230 TXV 34600 15 12.5 CBX25UH-042 778261514ACXS036-230 TXV 34400 15 12.5 CBX25UHV-036 762635014ACXS036-230 TXV 35200 16 13 CBX25UHV-042 778261614ACXS036-230 TXV 34200 16 13 CBX27UH-036 762635414ACXS036-230 TXV 35200 16 13 CBX27UH-042 778261714ACXS036-230 TXV 33400 14.5 12.2 CBX32M-030 762635714ACXS036-230 TXV 33800 14.5 12.2 CBX32M-036 778261814ACXS036-230 TXV 33800 14.5 12.2 CBX32M-042 762636014ACXS036-230 TXV 34800 15.1 12.5 CBX32M-048 778261914ACXS036-230 TXV 34000 15.1 12.5 CBX32MV-036 762636314ACXS036-230 TXV 35200 16 13 CBX32MV-048 778262014ACXS036-230 TXV 34200 15.1 12.5 CBX40UHV-036 762636614ACXS036-230 TXV 35000 15.5 12.5 CBX40UHV-042 778262114ACXS036-230 TXV 35000 16 13 CBX40UHV-048 762636914ACXS036-230 TXV 33600 15 12.5 CH23-41 EL180UH045E36A 778262314ACXS036-230 TXV 33600 15 12.5 CH23-41 EL180UH045XE36A 762637514ACXS036-230 TXV 33800 15.5 12.5 CH23-41 EL180UH070E36B 778262414ACXS036-230 TXV 33800 15.5 12.5 CH23-41 EL180UH070XE36B 762637814ACXS036-230 TXV 33800 15.5 12.5 CH23-41 EL180UH090E48B 778262514ACXS036-230 TXV 33800 15.5 12.5 CH23-41 EL180UH090XE48B 762638114ACXS036-230 TXV 33600 15.1 12.5 CH23-41 EL195UH045XE36B 778262614ACXS036-230 TXV 33800 15.1 12.5 CH23-41 EL195UH070XE36B 778262714ACXS036-230 TXV 33600 15.1 12.5 CH23-41 EL296UH045XE36B 762638414ACXS036-230 TXV 33800 15.1 12.5 CH23-41 EL296UH045XV36B 7782628NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 61

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS036-230 TXV 33800 15.1 12.5 CH23-41 EL296UH070XE36B 762638714ACXS036-230 TXV 33800 15.1 12.5 CH23-41 EL296UH070XV36B 762639014ACXS036-230 TXV 34000 16 13 CH23-41 SL280UH090V48B 778262214ACXS036-230 TXV 34000 16 13 CH23-41 SL280UH090XV48B 762637214ACXS036-230 TXV 33800 15.1 12.5 CH23-41 SLP98UH070XV36B 778262914ACXS036-230 TXV 33600 15 12.5 CH23-51 EL180UH045E36A 762639914ACXS036-230 TXV 33600 15 12.5 CH23-51 EL180UH045XE36A 778263214ACXS036-230 TXV 33800 15.5 12.5 CH23-51 EL180UH070E36B 762640214ACXS036-230 TXV 33800 15.5 12.5 CH23-51 EL180UH070XE36B 778263314ACXS036-230 TXV 33800 15.5 12.5 CH23-51 EL180UH090E48B 762640514ACXS036-230 TXV 34000 15.5 12.5 CH23-51 EL180UH090E60C 778263914ACXS036-230 TXV 33800 15.5 12.5 CH23-51 EL180UH090XE48B 778263414ACXS036-230 TXV 34000 15.5 12.5 CH23-51 EL180UH110E60C 762642314ACXS036-230 TXV 34000 15.5 12.5 CH23-51 EL180UH110XE60C 778264014ACXS036-230 TXV 33600 15.1 12.5 CH23-51 EL195UH045XE36B 762640814ACXS036-230 TXV 33800 15.1 12.5 CH23-51 EL195UH070XE36B 762641114ACXS036-230 TXV 33600 15.1 12.5 CH23-51 EL195UH090XE48C 762642614ACXS036-230 TXV 34000 15.5 12.5 CH23-51 EL195UH110XE60C 762642914ACXS036-230 TXV 33600 15.1 12.5 CH23-51 EL296UH045XE36B 778263514ACXS036-230 TXV 34000 15.1 12.5 CH23-51 EL296UH045XV36B 762641414ACXS036-230 TXV 33800 15.1 12.5 CH23-51 EL296UH070XE36B 778263614ACXS036-230 TXV 34000 15.1 12.5 CH23-51 EL296UH070XV36B 778263714ACXS036-230 TXV 33600 15.1 12.5 CH23-51 EL296UH090XE48C 778264114ACXS036-230 TXV 34000 15.5 12.5 CH23-51 EL296UH090XV36C 762643214ACXS036-230 TXV 33800 15.5 12.5 CH23-51 EL296UH090XV48C 762643514ACXS036-230 TXV 34000 15.5 12.5 CH23-51 EL296UH110XE60C 778264214ACXS036-230 TXV 34000 15.5 12.5 CH23-51 EL296UH110XV48C 762643814ACXS036-230 TXV 34200 15.5 12.5 CH23-51 EL296UH110XV60C 778264514ACXS036-230 TXV 34000 16 13 CH23-51 SL280UH090V36B 778263014ACXS036-230 TXV 34200 16 13 CH23-51 SL280UH090V48B 762639614ACXS036-230 TXV 34400 15.5 12.5 CH23-51 SL280UH090V60C 762835914ACXS036-230 TXV 34200 16 13 CH23-51 SL280UH090XV48B 778263114ACXS036-230 TXV 34400 15.5 12.5 CH23-51 SL280UH090XV60C 778317914ACXS036-230 TXV 34200 15.5 12.5 CH23-51 SL280UH110V60C 778263814ACXS036-230 TXV 34200 15.5 12.5 CH23-51 SL280UH110XV60C 762642014ACXS036-230 TXV 34000 15.1 12.5 CH23-51 SLP98UH070XV36B 762641714ACXS036-230 TXV 34000 15.5 12.5 CH23-51 SLP98UH090XV36C 778264314ACXS036-230 TXV 33800 15.5 12.5 CH23-51 SLP98UH090XV48C 778264414ACXS036-230 TXV 34200 15.5 12.5 CH23-51 SLP98UH110XV60C 762644114ACXS036-230 TXV 33400 14.25 11.5 CH23-51 762639314ACXS036-230 TXV 34000 15 12.5 CH33-31A EL180UH045E36A 778264714ACXS036-230 TXV 34000 15 12.5 CH33-31A EL180UH045XE36A 762644714ACXS036-230 TXV 34200 15.1 12.5 CH33-31A SL280UH070V36A 778264614ACXS036-230 TXV 34200 15.1 12.5 CH33-31A SL280UH070XV36A 762644414ACXS036-230 TXV 34600 15.1 12.5 CH33-31B EL180UH070E36B 762645714ACXS036-230 TXV 34600 15.1 12.5 CH33-31B EL180UH070XE36B 778265114ACXS036-230 TXV 34600 15.5 12.5 CH33-31B EL180UH090E48B 762646014ACXS036-230 TXV 34600 15.5 12.5 CH33-31B EL180UH090XE48B 778265214ACXS036-230 TXV 34200 14.5 12.2 CH33-31B EL195UH045XE36B 7626463NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 62

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS036-230 TXV 34400 15 12.5 CH33-31B EL195UH070XE36B 762646614ACXS036-230 TXV 34200 14.5 12.2 CH33-31B EL296UH045XE36B 778265314ACXS036-230 TXV 34600 15.1 12.5 CH33-31B EL296UH045XV36B 762646914ACXS036-230 TXV 34400 15 12.5 CH33-31B EL296UH070XE36B 778265414ACXS036-230 TXV 34600 15.1 12.5 CH33-31B EL296UH070XV36B 778265514ACXS036-230 TXV 34800 16 13 CH33-31B SL280UH090V36B 778264914ACXS036-230 TXV 34800 15.5 12.5 CH33-31B SL280UH090V48B 762645414ACXS036-230 TXV 34800 15.5 12.5 CH33-31B SL280UH090XV48B 778265014ACXS036-230 TXV 34600 15.1 12.5 CH33-31B SLP98UH070XV36B 762647214ACXS036-230 TXV 34200 14.5 12.2 CH33-31B 762645114ACXS036-230 TXV 33000 14.5 12.2 CH33-36A EL180UH045E36A 778265714ACXS036-230 TXV 33000 14.5 12.2 CH33-36A EL180UH045XE36A 762647814ACXS036-230 TXV 33200 14.5 12.2 CH33-36A SL280UH070V36A 778265614ACXS036-230 TXV 33200 14.5 12.2 CH33-36A SL280UH070XV36A 762647514ACXS036-230 TXV 33400 15.5 12.5 CH33-36B EL180UH070E36B 778266014ACXS036-230 TXV 33400 15.5 12.5 CH33-36B EL180UH070XE36B 762648714ACXS036-230 TXV 33400 15.1 12.5 CH33-36B EL180UH090E48B 778266114ACXS036-230 TXV 33400 15.1 12.5 CH33-36B EL180UH090XE48B 762649014ACXS036-230 TXV 33000 15 12.5 CH33-36B EL195UH045XE36B 778266214ACXS036-230 TXV 33200 15 12.5 CH33-36B EL195UH070XE36B 778266314ACXS036-230 TXV 33000 15 12.5 CH33-36B EL296UH045XE36B 762649314ACXS036-230 TXV 33400 14.5 12.2 CH33-36B EL296UH045XV36B 762836214ACXS036-230 TXV 33200 15 12.5 CH33-36B EL296UH070XE36B 762649614ACXS036-230 TXV 33400 15 12.5 CH33-36B EL296UH070XV36B 778266414ACXS036-230 TXV 33400 15.5 12.5 CH33-36B SL280UH090V36B 762648114ACXS036-230 TXV 33600 15.5 12.5 CH33-36B SL280UH090V48B 778265914ACXS036-230 TXV 33600 15.5 12.5 CH33-36B SL280UH090XV48B 762648414ACXS036-230 TXV 33400 15 12.5 CH33-36B SLP98UH070XV36B 762649914ACXS036-230 TXV 33000 14 11.5 CH33-36B 778265814ACXS036-230 TXV 33800 15.5 12.5 CH33-36C EL180UH090E60C 762650514ACXS036-230 TXV 33800 15.5 12.5 CH33-36C EL180UH110E60C 778266714ACXS036-230 TXV 33800 15.5 12.5 CH33-36C EL180UH110XE60C 762650814ACXS036-230 TXV 33600 15.1 12.5 CH33-36C EL195UH090XE48C 778266814ACXS036-230 TXV 34000 15.5 12.5 CH33-36C EL195UH110XE60C 778266914ACXS036-230 TXV 33600 15.1 12.5 CH33-36C EL296UH090XE48C 762651114ACXS036-230 TXV 34000 15.5 12.5 CH33-36C EL296UH090XV36C 778267014ACXS036-230 TXV 33800 15.5 12.5 CH33-36C EL296UH090XV48C 778267114ACXS036-230 TXV 34000 15.5 12.5 CH33-36C EL296UH110XE60C 762651414ACXS036-230 TXV 34000 15.5 12.5 CH33-36C EL296UH110XV48C 778267214ACXS036-230 TXV 34200 15.5 12.5 CH33-36C EL296UH110XV60C 762652314ACXS036-230 TXV 34400 15.5 12.5 CH33-36C SL280UH090V60C 778318014ACXS036-230 TXV 34400 15.5 12.5 CH33-36C SL280UH090XV60C 762836514ACXS036-230 TXV 34200 15.5 12.5 CH33-36C SL280UH110V60C 762650214ACXS036-230 TXV 34200 15.5 12.5 CH33-36C SL280UH110XV60C 778266614ACXS036-230 TXV 34000 15.5 12.5 CH33-36C SLP98UH090XV36C 762651714ACXS036-230 TXV 33800 15.5 12.5 CH33-36C SLP98UH090XV48C 762652014ACXS036-230 TXV 34200 15.5 12.5 CH33-36C SLP98UH110XV60C 778267314ACXS036-230 TXV 33400 14.25 11.5 CH33-36C 778266514ACXS036-230 TXV 34200 15 12.5 CH33-42B EL180UH070E36B 7628372NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 63

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS036-230 TXV 34200 15 12.5 CH33-42B EL180UH070XE36B 762837514ACXS036-230 TXV 34200 15.5 12.5 CH33-42B EL180UH090E48B 762837714ACXS036-230 TXV 34200 15.5 12.5 CH33-42B EL180UH090XE48B 762838014ACXS036-230 TXV 34000 14.5 12.2 CH33-42B EL195UH045XE36B 762838314ACXS036-230 TXV 34000 15.1 12.5 CH33-42B EL195UH070XE36B 762838814ACXS036-230 TXV 34000 14.5 12.2 CH33-42B EL296UH045XE36B 762838514ACXS036-230 TXV 34200 15 12.5 CH33-42B EL296UH045XV36B 778318414ACXS036-230 TXV 34000 15.1 12.5 CH33-42B EL296UH070XE36B 762839014ACXS036-230 TXV 34200 15.1 12.5 CH33-42B EL296UH070XV36B 762839314ACXS036-230 TXV 34400 15.5 12.5 CH33-42B SL280UH090V36B 778318214ACXS036-230 TXV 34400 15.5 12.5 CH33-42B SL280UH090V48B 762836814ACXS036-230 TXV 34400 15.5 12.5 CH33-42B SL280UH090XV48B 778318314ACXS036-230 TXV 34200 15.1 12.5 CH33-42B SLP98UH070XV36B 778318514ACXS036-230 TXV 35000 16 13 CH33-43B EL180UH070E36B 778267614ACXS036-230 TXV 35000 16 13 CH33-43B EL180UH070XE36B 762653614ACXS036-230 TXV 35400 16 13 CH33-43B EL180UH090E48B 778267714ACXS036-230 TXV 35400 16 13 CH33-43B EL180UH090XE48B 762653914ACXS036-230 TXV 35000 15.1 12.5 CH33-43B EL195UH045XE36B 778267814ACXS036-230 TXV 35000 15.1 12.5 CH33-43B EL195UH070XE36B 778267914ACXS036-230 TXV 35000 15.1 12.5 CH33-43B EL296UH045XE36B 762654214ACXS036-230 TXV 35400 15.5 12.5 CH33-43B EL296UH045XV36B 778268014ACXS036-230 TXV 35000 15.1 12.5 CH33-43B EL296UH070XE36B 762654514ACXS036-230 TXV 35400 15.5 12.5 CH33-43B EL296UH070XV36B 762654814ACXS036-230 TXV 35400 16 13 CH33-43B SL280UH090V36B 762653014ACXS036-230 TXV 35400 16 13 CH33-43B SL280UH090V48B 778267514ACXS036-230 TXV 35400 16 13 CH33-43B SL280UH090XV48B 762653314ACXS036-230 TXV 35400 15.5 12.5 CH33-43B SLP98UH070XV36B 778268114ACXS036-230 TXV 35000 14.5 12.2 CH33-43B 778267414ACXS036-230 TXV 35000 16 13 CH33-43C EL180UH090E60C 762655714ACXS036-230 TXV 35000 16 13 CH33-43C EL180UH110E60C 778268414ACXS036-230 TXV 35000 16 13 CH33-43C EL180UH110XE60C 762656014ACXS036-230 TXV 34800 16 13 CH33-43C EL195UH090XE48C 778268514ACXS036-230 TXV 35000 16 13 CH33-43C EL195UH110XE60C 778268614ACXS036-230 TXV 34800 16 13 CH33-43C EL296UH090XE48C 762656314ACXS036-230 TXV 35000 16 13 CH33-43C EL296UH090XV36C 778268714ACXS036-230 TXV 35000 16 13 CH33-43C EL296UH090XV48C 778268814ACXS036-230 TXV 35000 16 13 CH33-43C EL296UH110XE60C 762656614ACXS036-230 TXV 35200 16 13 CH33-43C EL296UH110XV48C 778268914ACXS036-230 TXV 35400 16 13 CH33-43C EL296UH110XV60C 762657514ACXS036-230 TXV 35600 16 13 CH33-43C SL280UH090V60C 762655114ACXS036-230 TXV 35600 16 13 CH33-43C SL280UH090XV60C 778268214ACXS036-230 TXV 35400 16 13 CH33-43C SL280UH110V60C 762655414ACXS036-230 TXV 35400 16 13 CH33-43C SL280UH110XV60C 778268314ACXS036-230 TXV 35000 16 13 CH33-43C SLP98UH090XV36C 762656914ACXS036-230 TXV 35000 16 13 CH33-43C SLP98UH090XV48C 762657214ACXS036-230 TXV 35400 16 13 CH33-43C SLP98UH110XV60C 778269014ACXS036-230 TXV 34600 15.1 12.5 CH33-44/48B EL180UH070E36B 778269214ACXS036-230 TXV 34600 15.1 12.5 CH33-44/48B EL180UH070XE36B 762658814ACXS036-230 TXV 34600 15.5 12.5 CH33-44/48B EL180UH090E48B 7782693NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 64

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS036-230 TXV 34600 15.5 12.5 CH33-44/48B EL180UH090XE48B 762659114ACXS036-230 TXV 34400 14.5 12.2 CH33-44/48B EL195UH045XE36B 778269414ACXS036-230 TXV 34400 15 12.5 CH33-44/48B EL195UH070XE36B 778269514ACXS036-230 TXV 34400 14.5 12.2 CH33-44/48B EL296UH045XE36B 762659414ACXS036-230 TXV 34600 15.1 12.5 CH33-44/48B EL296UH045XV36B 778269614ACXS036-230 TXV 34400 15 12.5 CH33-44/48B EL296UH070XE36B 762659714ACXS036-230 TXV 34600 15.1 12.5 CH33-44/48B EL296UH070XV36B 762660014ACXS036-230 TXV 34800 16 13 CH33-44/48B SL280UH090V36B 762658114ACXS036-230 TXV 34800 15.5 12.5 CH33-44/48B SL280UH090V48B 762658414ACXS036-230 TXV 34800 15.5 12.5 CH33-44/48B SL280UH090XV48B 762658514ACXS036-230 TXV 34600 15.1 12.5 CH33-44/48B SLP98UH070XV36B 778269714ACXS036-230 TXV 34200 14.5 12.2 CH33-44/48B 778269114ACXS036-230 TXV 34800 16 13 CH33-48C EL180UH090E60C 778270014ACXS036-230 TXV 34800 16 13 CH33-48C EL180UH110E60C 762661314ACXS036-230 TXV 34800 16 13 CH33-48C EL180UH110XE60C 778270114ACXS036-230 TXV 34600 15.5 12.5 CH33-48C EL195UH090XE48C 762661614ACXS036-230 TXV 35000 16 13 CH33-48C EL195UH110XE60C 762661914ACXS036-230 TXV 34600 15.5 12.5 CH33-48C EL296UH090XE48C 778270214ACXS036-230 TXV 35000 16 13 CH33-48C EL296UH090XV36C 762662214ACXS036-230 TXV 34800 16 13 CH33-48C EL296UH090XV48C 762662514ACXS036-230 TXV 35000 16 13 CH33-48C EL296UH110XE60C 778270314ACXS036-230 TXV 35000 16 13 CH33-48C EL296UH110XV48C 762662814ACXS036-230 TXV 35200 16 13 CH33-48C EL296UH110XV60C 778270614ACXS036-230 TXV 35400 16 13 CH33-48C SL280UH090V60C 778269814ACXS036-230 TXV 35400 16 13 CH33-48C SL280UH090XV60C 762660714ACXS036-230 TXV 35200 16 13 CH33-48C SL280UH110V60C 778269914ACXS036-230 TXV 35200 16 13 CH33-48C SL280UH110XV60C 762661014ACXS036-230 TXV 35000 16 13 CH33-48C SLP98UH090XV36C 778270414ACXS036-230 TXV 34800 16 13 CH33-48C SLP98UH090XV48C 778270514ACXS036-230 TXV 35200 16 13 CH33-48C SLP98UH110XV60C 762663114ACXS036-230 TXV 34400 14.5 12.2 CH33-48C 762660414ACXS036-230 TXV 35400 16 13 CH33-49 EL180UH090E60C 778318914ACXS036-230 TXV 35400 16 13 CH33-49 EL180UH110E60C 762840814ACXS036-230 TXV 35400 16 13 CH33-49 EL180UH110XE60C 778319014ACXS036-230 TXV 35000 16 13 CH33-49 EL195UH090XE48C 762841114ACXS036-230 TXV 35400 16 13 CH33-49 EL195UH110XE60C 762841514ACXS036-230 TXV 35000 16 13 CH33-49 EL296UH090XE48C 778319114ACXS036-230 TXV 35400 16 13 CH33-49 EL296UH090XV36C 778319214ACXS036-230 TXV 35200 16 13 CH33-49 EL296UH090XV48C 762842314ACXS036-230 TXV 35400 16 13 CH33-49 EL296UH110XE60C 762841814ACXS036-230 TXV 35400 16 13 CH33-49 EL296UH110XV48C 762842914ACXS036-230 TXV 35800 16 13 CH33-49 EL296UH110XV60C 762843014ACXS036-230 TXV 35800 16 13 CH33-49 SL280UH090V60C 778318714ACXS036-230 TXV 35800 16 13 CH33-49 SL280UH090XV60C 762840214ACXS036-230 TXV 35600 16 13 CH33-49 SL280UH110V60C 778318814ACXS036-230 TXV 35600 16 13 CH33-49 SL280UH110XV60C 762840514ACXS036-230 TXV 35400 16 13 CH33-49 SLP98UH090XV36C 762842114ACXS036-230 TXV 35200 16 13 CH33-49 SLP98UH090XV48C 762842614ACXS036-230 TXV 35800 16 13 CH33-49 SLP98UH110XV60C 7783193NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 65

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS036-230 TXV 34800 14.5 12.2 CH33-49 762839914ACXS036-230 TXV 35200 16 13 CH33-50/60C EL180UH090E60C 778270914ACXS036-230 TXV 35200 16 13 CH33-50/60C EL180UH110E60C 762664014ACXS036-230 TXV 35200 16 13 CH33-50/60C EL180UH110XE60C 778271014ACXS036-230 TXV 35000 16 13 CH33-50/60C EL195UH090XE48C 762664314ACXS036-230 TXV 35200 16 13 CH33-50/60C EL195UH110XE60C 762664614ACXS036-230 TXV 35000 16 13 CH33-50/60C EL296UH090XE48C 778271114ACXS036-230 TXV 35200 16 13 CH33-50/60C EL296UH090XV36C 762664914ACXS036-230 TXV 35000 16 13 CH33-50/60C EL296UH090XV48C 762665214ACXS036-230 TXV 35200 16 13 CH33-50/60C EL296UH110XE60C 778271214ACXS036-230 TXV 35200 16 13 CH33-50/60C EL296UH110XV48C 762665514ACXS036-230 TXV 35600 16 13 CH33-50/60C EL296UH110XV60C 778271514ACXS036-230 TXV 35600 16 13 CH33-50/60C SL280UH090V60C 778270714ACXS036-230 TXV 35600 16 13 CH33-50/60C SL280UH090XV60C 762663414ACXS036-230 TXV 35600 16 13 CH33-50/60C SL280UH110V60C 778270814ACXS036-230 TXV 35600 16 13 CH33-50/60C SL280UH110XV60C 762663714ACXS036-230 TXV 35200 16 13 CH33-50/60C SLP98UH090XV36C 778271314ACXS036-230 TXV 35000 16 13 CH33-50/60C SLP98UH090XV48C 778271414ACXS036-230 TXV 35600 16 13 CH33-50/60C SLP98UH110XV60C 762665814ACXS036-230 TXV 34600 14.5 12.2 CH33-50/60C 762666114ACXS036-230 TXV 34000 15 12.5 CH35-30A EL180UH045E36A 778271814ACXS036-230 TXV 34000 15 12.5 CH35-30A EL180UH045XE36A 762666714ACXS036-230 TXV 34200 15.1 12.5 CH35-30A SL280UH070V36A 778271714ACXS036-230 TXV 34200 15.1 12.5 CH35-30A SL280UH070XV36A 762666414ACXS036-230 TXV 34800 15.1 12.5 CH35-30B EL180UH070E36B 778272114ACXS036-230 TXV 34800 15.1 12.5 CH35-30B EL180UH070XE36B 762667614ACXS036-230 TXV 34800 16 13 CH35-30B EL180UH090E48B 778272214ACXS036-230 TXV 34800 16 13 CH35-30B EL180UH090XE48B 762667914ACXS036-230 TXV 34400 14.5 12.2 CH35-30B EL195UH045XE36B 778272314ACXS036-230 TXV 34400 15 12.5 CH35-30B EL195UH070XE36B 778272414ACXS036-230 TXV 34400 14.5 12.2 CH35-30B EL296UH045XE36B 762668214ACXS036-230 TXV 34600 15.1 12.5 CH35-30B EL296UH045XV36B 778272514ACXS036-230 TXV 34400 15 12.5 CH35-30B EL296UH070XE36B 762668514ACXS036-230 TXV 34600 15.1 12.5 CH35-30B EL296UH070XV36B 762668814ACXS036-230 TXV 34800 16 13 CH35-30B SL280UH090V36B 762667014ACXS036-230 TXV 34800 15.5 12.5 CH35-30B SL280UH090V48B 778272014ACXS036-230 TXV 34800 15.5 12.5 CH35-30B SL280UH090XV48B 762667314ACXS036-230 TXV 34600 15.1 12.5 CH35-30B SLP98UH070XV36B 778272614ACXS036-230 TXV 34200 14.5 12.2 CH35-30B 778271914ACXS036-230 TXV 33000 14.5 12.2 CH35-36A EL180UH045E36A 762669414ACXS036-230 TXV 33000 14.5 12.2 CH35-36A EL180UH045XE36A 778272814ACXS036-230 TXV 33200 14.5 12.2 CH35-36A SL280UH070V36A 762669114ACXS036-230 TXV 33200 14.5 12.2 CH35-36A SL280UH070XV36A 778272714ACXS036-230 TXV 33400 15.5 12.5 CH35-36B EL180UH070E36B 762670414ACXS036-230 TXV 33400 15.5 12.5 CH35-36B EL180UH070XE36B 778273114ACXS036-230 TXV 33400 15.1 12.5 CH35-36B EL180UH090E48B 762670714ACXS036-230 TXV 33400 15.1 12.5 CH35-36B EL180UH090XE48B 778273214ACXS036-230 TXV 33000 15 12.5 CH35-36B EL195UH045XE36B 762671014ACXS036-230 TXV 33200 14.5 12 CH35-36B EL195UH070XE36B 7626714NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 66

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS036-230 TXV 33000 15 12.5 CH35-36B EL296UH045XE36B 778273314ACXS036-230 TXV 33600 15 12.2 CH35-36B EL296UH045XV36B 762671714ACXS036-230 TXV 33200 14.5 12 CH35-36B EL296UH070XE36B 778273414ACXS036-230 TXV 33400 15 12.5 CH35-36B EL296UH070XV36B 778273514ACXS036-230 TXV 33600 15.5 12.5 CH35-36B SL280UH090V36B 778272914ACXS036-230 TXV 33800 15.5 12.5 CH35-36B SL280UH090V48B 762670114ACXS036-230 TXV 33800 15.5 12.5 CH35-36B SL280UH090XV48B 778273014ACXS036-230 TXV 33400 15 12.5 CH35-36B SLP98UH070XV36B 762672014ACXS036-230 TXV 33000 14 11.5 CH35-36B 762669814ACXS036-230 TXV 34000 15.5 12.5 CH35-36C EL180UH090E60C 762672714ACXS036-230 TXV 33800 15.5 12.5 CH35-36C EL180UH110E60C 778273814ACXS036-230 TXV 33800 15.5 12.5 CH35-36C EL180UH110XE60C 762673014ACXS036-230 TXV 33600 15.1 12.5 CH35-36C EL195UH090XE48C 778273914ACXS036-230 TXV 34000 15.5 12.5 CH35-36C EL195UH110XE60C 778274014ACXS036-230 TXV 33600 15.1 12.5 CH35-36C EL296UH090XE48C 762673314ACXS036-230 TXV 34000 15.5 12.5 CH35-36C EL296UH090XV36C 778274114ACXS036-230 TXV 33800 15.5 12.5 CH35-36C EL296UH090XV48C 778274214ACXS036-230 TXV 34000 15.5 12.5 CH35-36C EL296UH110XE60C 762673614ACXS036-230 TXV 34000 15.5 12.5 CH35-36C EL296UH110XV48C 778274314ACXS036-230 TXV 34400 15.5 12.5 CH35-36C EL296UH110XV60C 778319514ACXS036-230 TXV 34400 15.5 12.5 CH35-36C SL280UH090V60C 778319414ACXS036-230 TXV 34400 15.5 12.5 CH35-36C SL280UH090XV60C 762843514ACXS036-230 TXV 34200 15.5 12.5 CH35-36C SL280UH110V60C 762672314ACXS036-230 TXV 34200 15.5 12.5 CH35-36C SL280UH110XV60C 778273714ACXS036-230 TXV 34000 15.5 12.5 CH35-36C SLP98UH090XV36C 762673914ACXS036-230 TXV 33800 15.5 12.5 CH35-36C SLP98UH090XV48C 762674314ACXS036-230 TXV 34400 15.5 12.5 CH35-36C SLP98UH110XV60C 762674614ACXS036-230 TXV 33400 14.25 11.5 CH35-36C 778273614ACXS036-230 TXV 35000 16 13 CH35-42B EL180UH070E36B 778274614ACXS036-230 TXV 35000 16 13 CH35-42B EL180UH070XE36B 762675514ACXS036-230 TXV 35400 16 13 CH35-42B EL180UH090E48B 778274714ACXS036-230 TXV 35400 16 13 CH35-42B EL180UH090XE48B 762675914ACXS036-230 TXV 35000 15.1 12.5 CH35-42B EL195UH045XE36B 778274814ACXS036-230 TXV 35200 15.1 12.5 CH35-42B EL195UH070XE36B 778274914ACXS036-230 TXV 35000 15.1 12.5 CH35-42B EL296UH045XE36B 762676214ACXS036-230 TXV 35400 15.5 12.5 CH35-42B EL296UH045XV36B 778275014ACXS036-230 TXV 35200 15.1 12.5 CH35-42B EL296UH070XE36B 762676514ACXS036-230 TXV 35400 15.5 12.5 CH35-42B EL296UH070XV36B 762676814ACXS036-230 TXV 35400 16 13 CH35-42B SL280UH090V36B 762674914ACXS036-230 TXV 35600 16 13 CH35-42B SL280UH090V48B 778274514ACXS036-230 TXV 35600 16 13 CH35-42B SL280UH090XV48B 762675214ACXS036-230 TXV 35400 15.5 12.5 CH35-42B SLP98UH070XV36B 778275114ACXS036-230 TXV 35000 14.5 12.2 CH35-42B 778274414ACXS036-230 TXV 35200 16 13 CH35-42C EL180UH090E60C 778275414ACXS036-230 TXV 35000 16 13 CH35-42C EL180UH110E60C 762678114ACXS036-230 TXV 35000 16 13 CH35-42C EL180UH110XE60C 778275514ACXS036-230 TXV 34800 16 13 CH35-42C EL195UH090XE48C 762678414ACXS036-230 TXV 35200 16 13 CH35-42C EL195UH110XE60C 762678714ACXS036-230 TXV 34800 16 13 CH35-42C EL296UH090XE48C 7782756NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 67

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS036-230 TXV 35200 16 13 CH35-42C EL296UH090XV36C 762679114ACXS036-230 TXV 35000 16 13 CH35-42C EL296UH090XV48C 762679414ACXS036-230 TXV 35200 16 13 CH35-42C EL296UH110XE60C 778275714ACXS036-230 TXV 35200 16 13 CH35-42C EL296UH110XV48C 762679914ACXS036-230 TXV 35400 16 13 CH35-42C EL296UH110XV60C 762680214ACXS036-230 TXV 35600 16 13 CH35-42C SL280UH090V60C 778275214ACXS036-230 TXV 35600 16 13 CH35-42C SL280UH090XV60C 762677514ACXS036-230 TXV 35400 16 13 CH35-42C SL280UH110V60C 778275314ACXS036-230 TXV 35400 16 13 CH35-42C SL280UH110XV60C 762677814ACXS036-230 TXV 35200 16 13 CH35-42C SLP98UH090XV36C 778275814ACXS036-230 TXV 35000 16 13 CH35-42C SLP98UH090XV48C 762679614ACXS036-230 TXV 35400 16 13 CH35-42C SLP98UH110XV60C 778275914ACXS036-230 TXV 34600 14.5 12.2 CH35-42C 762677214ACXS036-230 TXV 34800 15.1 12.5 CH35-48B EL180UH070E36B 762681314ACXS036-230 TXV 34800 15.1 12.5 CH35-48B EL180UH070XE36B 762681614ACXS036-230 TXV 34800 16 13 CH35-48B EL180UH090E48B 762681814ACXS036-230 TXV 34800 16 13 CH35-48B EL180UH090XE48B 778276114ACXS036-230 TXV 34400 15 12.2 CH35-48B EL195UH045XE36B 762682114ACXS036-230 TXV 34600 15 12.5 CH35-48B EL195UH070XE36B 762682714ACXS036-230 TXV 34400 15 12.2 CH35-48B EL296UH045XE36B 762682414ACXS036-230 TXV 35000 15.1 12.5 CH35-48B EL296UH045XV36B 762683214ACXS036-230 TXV 34600 15 12.5 CH35-48B EL296UH070XE36B 762682914ACXS036-230 TXV 34800 15.5 12.5 CH35-48B EL296UH070XV36B 762683514ACXS036-230 TXV 35000 16 13 CH35-48B SL280UH090V36B 778276014ACXS036-230 TXV 35000 16 13 CH35-48B SL280UH090V48B 762680814ACXS036-230 TXV 35000 16 13 CH35-48B SL280UH090XV48B 762681114ACXS036-230 TXV 34800 15.5 12.5 CH35-48B SLP98UH070XV36B 762683714ACXS036-230 TXV 34400 14.5 12.2 CH35-48B 762680514ACXS036-230 TXV 35000 16 13 CH35-48C EL180UH090E60C 762685314ACXS036-230 TXV 35000 16 13 CH35-48C EL180UH110E60C 778276214ACXS036-230 TXV 35000 16 13 CH35-48C EL180UH110XE60C 762685614ACXS036-230 TXV 34800 16 13 CH35-48C EL195UH090XE48C 778276314ACXS036-230 TXV 35000 16 13 CH35-48C EL195UH110XE60C 778276414ACXS036-230 TXV 34800 16 13 CH35-48C EL296UH090XE48C 762685914ACXS036-230 TXV 35000 16 13 CH35-48C EL296UH090XV36C 778276514ACXS036-230 TXV 34800 16 13 CH35-48C EL296UH090XV48C 778276614ACXS036-230 TXV 35000 16 13 CH35-48C EL296UH110XE60C 762686314ACXS036-230 TXV 35000 16 13 CH35-48C EL296UH110XV48C 778276714ACXS036-230 TXV 35400 16 13 CH35-48C EL296UH110XV60C 762687214ACXS036-230 TXV 35400 16 13 CH35-48C SL280UH090V60C 762684314ACXS036-230 TXV 35400 16 13 CH35-48C SL280UH090XV60C 762684514ACXS036-230 TXV 35400 16 13 CH35-48C SL280UH110V60C 762684814ACXS036-230 TXV 35400 16 13 CH35-48C SL280UH110XV60C 762685114ACXS036-230 TXV 35000 16 13 CH35-48C SLP98UH090XV36C 762686614ACXS036-230 TXV 34800 16 13 CH35-48C SLP98UH090XV48C 762686914ACXS036-230 TXV 35400 16 13 CH35-48C SLP98UH110XV60C 762687414ACXS036-230 TXV 34400 14.5 12.2 CH35-48C 762684014ACXS036-230 TXV 35400 16 13 CH35-51C EL180UH090E60C 778276914ACXS036-230 TXV 35400 16 13 CH35-51C EL180UH110E60C 7626888NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 68

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS036-230 TXV 35400 16 13 CH35-51C EL180UH110XE60C 778277014ACXS036-230 TXV 35200 16 13 CH35-51C EL195UH090XE48C 762689114ACXS036-230 TXV 35400 16 13 CH35-51C EL195UH110XE60C 762689414ACXS036-230 TXV 35200 16 13 CH35-51C EL296UH090XE48C 778277114ACXS036-230 TXV 35400 16 13 CH35-51C EL296UH090XV36C 762689714ACXS036-230 TXV 35200 16 13 CH35-51C EL296UH090XV48C 762690014ACXS036-230 TXV 35400 16 13 CH35-51C EL296UH110XE60C 778277214ACXS036-230 TXV 35400 16 13 CH35-51C EL296UH110XV48C 762690314ACXS036-230 TXV 35800 16 13 CH35-51C EL296UH110XV60C 778277514ACXS036-230 TXV 36000 16 13 CH35-51C SL280UH090V60C 762688014ACXS036-230 TXV 36000 16 13 CH35-51C SL280UH090XV60C 762688214ACXS036-230 TXV 35800 16 13 CH35-51C SL280UH110V60C 778276814ACXS036-230 TXV 35800 16 13 CH35-51C SL280UH110XV60C 762688514ACXS036-230 TXV 35400 16 13 CH35-51C SLP98UH090XV36C 778277314ACXS036-230 TXV 35200 16 13 CH35-51C SLP98UH090XV48C 778277414ACXS036-230 TXV 35800 16 13 CH35-51C SLP98UH110XV60C 762690614ACXS036-230 TXV 34800 14.5 12.2 CH35-51C 762687714ACXS036-230 TXV 33600 14.5 12.2 CR33-30/36A EL180DF045E36A 762690914ACXS036-230 TXV 33600 15 12.5 CR33-30/36A SL280DF070V36A 778277614ACXS036-230 TXV 33600 15.5 12.5 CR33-30/36B EL180DF070E36B 778277814ACXS036-230 TXV 33600 15.1 12.5 CR33-30/36B EL180DF090E48B 762691614ACXS036-230 TXV 33400 14.5 12 CR33-30/36B EL195DF045XE36B 778277914ACXS036-230 TXV 33600 15.1 12.5 CR33-30/36B EL195DF070XE48B 778278014ACXS036-230 TXV 33400 14.5 12 CR33-30/36B EL296DF045XE36B 762691914ACXS036-230 TXV 33600 15 12.2 CR33-30/36B EL296DF045XV36B 762692414ACXS036-230 TXV 33600 15.1 12.5 CR33-30/36B EL296DF070XE48B 762692214ACXS036-230 TXV 33600 14.5 12.2 CR33-30/36B EL296DF070XV48B 762692714ACXS036-230 TXV 33800 15.1 12.5 CR33-30/36B SL280DF090V48B 762691314ACXS036-230 TXV 33800 15 12.5 CR33-30/36B SLP98DF070XV36B 762693014ACXS036-230 TXV 33400 14.25 11.5 CR33-30/36B 778277714ACXS036-230 TXV 33800 15.5 12.5 CR33-30/36C EL180DF110E60C 762693814ACXS036-230 TXV 33600 15.1 12.5 CR33-30/36C EL195DF090XE48C 762694014ACXS036-230 TXV 33600 15.1 12.5 CR33-30/36C EL195DF110XE60C 778278114ACXS036-230 TXV 33600 15.1 12.5 CR33-30/36C EL296DF090XE48C 762694314ACXS036-230 TXV 34000 15.1 12.5 CR33-30/36C EL296DF090XV60C 778278314ACXS036-230 TXV 33600 15.1 12.5 CR33-30/36C EL296DF110XE60C 762694614ACXS036-230 TXV 34000 15.1 12.5 CR33-30/36C EL296DF110XV60C 778278414ACXS036-230 TXV 34000 15.5 12.5 CR33-30/36C SL280DF110V60C 762693514ACXS036-230 TXV 33800 15.1 12.5 CR33-30/36C SLP98DF090XV36C 778278214ACXS036-230 TXV 33800 15.1 12.5 CR33-30/36C SLP98DF090XV48C 762694914ACXS036-230 TXV 34000 15.1 12.5 CR33-30/36C SLP98DF090XV60C 762695214ACXS036-230 TXV 34000 15.1 12.5 CR33-30/36C SLP98DF110XV60C 762695514ACXS036-230 TXV 33400 14.25 11.5 CR33-30/36C 762693214ACXS036-230 TXV 34200 15 12.5 CR33-48B EL180DF070E36B 778319714ACXS036-230 TXV 34200 15.5 12.5 CR33-48B EL180DF090E48B 762844414ACXS036-230 TXV 34000 15.1 12.5 CR33-48B EL195DF045XE36B 778319814ACXS036-230 TXV 34000 15.5 12.5 CR33-48B EL195DF070XE48B 778319914ACXS036-230 TXV 34000 15.5 12.5 CR33-48B EL296DF045XE36B 762844714ACXS036-230 TXV 34200 15.1 12.5 CR33-48B EL296DF045XV36B 7783200NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 69

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS036-230 TXV 34000 15.5 12.5 CR33-48B EL296DF070XE48B 762845014ACXS036-230 TXV 34200 15.1 12.5 CR33-48B EL296DF070XV48B 762845314ACXS036-230 TXV 34600 15.5 12.5 CR33-48B SL280DF090V48B 762844114ACXS036-230 TXV 34000 15.5 12.5 CR33-48B SLP98DF070XV36B 778320114ACXS036-230 TXV 33800 14.25 12 CR33-48B 778319614ACXS036-230 TXV 34400 16 13 CR33-48C EL180DF110E60C 778320314ACXS036-230 TXV 34200 15.5 12.5 CR33-48C EL195DF090XE48C 762846214ACXS036-230 TXV 34200 15.5 12.5 CR33-48C EL195DF110XE60C 762846514ACXS036-230 TXV 34200 15.5 12.5 CR33-48C EL296DF090XE48C 778320414ACXS036-230 TXV 34600 15.5 12.5 CR33-48C EL296DF090XV60C 762847114ACXS036-230 TXV 34200 15.5 12.5 CR33-48C EL296DF110XE60C 778320514ACXS036-230 TXV 34600 15.5 12.5 CR33-48C EL296DF110XV60C 762847414ACXS036-230 TXV 34600 16 13 CR33-48C SL280DF110V60C 762845914ACXS036-230 TXV 34400 15.5 12.5 CR33-48C SLP98DF090XV36C 762846814ACXS036-230 TXV 34400 16 13 CR33-48C SLP98DF090XV48C 778320614ACXS036-230 TXV 34600 15.5 12.5 CR33-48C SLP98DF090XV60C 778320714ACXS036-230 TXV 34600 15.5 12.5 CR33-48C SLP98DF110XV60C 778320814ACXS036-230 TXV 33800 14.25 12 CR33-48C 778320214ACXS036-230 TXV 33200 14.5 12.2 CX35-30/36A EL180UH045E36A 825917614ACXS036-230 TXV 33200 14.5 12.2 CX35-30/36A EL180UH045XE36A 825917314ACXS036-230 TXV 33400 15 12.2 CX35-30/36A SL280UH070V36A 825917514ACXS036-230 TXV 33400 15 12.2 CX35-30/36A SL280UH070XV36A 825917114ACXS036-230 TXV 33000 14 11.5 CX35-30/36A 825917014ACXS036-230 TXV 33400 15.5 12.5 CX35-30/36B EL180UH070E36B 825919114ACXS036-230 TXV 33400 15.5 12.5 CX35-30/36B EL180UH070XE36B 825918014ACXS036-230 TXV 33400 15.1 12.5 CX35-30/36B EL180UH090E48B 825919314ACXS036-230 TXV 33400 15.1 12.5 CX35-30/36B EL180UH090XE48B 825918114ACXS036-230 TXV 33000 15 12.5 CX35-30/36B EL195UH045XE36B 825919414ACXS036-230 TXV 33200 14.5 12 CX35-30/36B EL195UH070XE36B 825919614ACXS036-230 TXV 33000 15 12.5 CX35-30/36B EL296UH045XE36B 825918314ACXS036-230 TXV 33400 15 12.5 CX35-30/36B EL296UH045XV36B 825919714ACXS036-230 TXV 33200 14.5 12 CX35-30/36B EL296UH070XE36B 825918414ACXS036-230 TXV 33400 15 12.5 CX35-30/36B EL296UH070XV36B 825918614ACXS036-230 TXV 33600 15.5 12.5 CX35-30/36B SL280UH090V36B 825918814ACXS036-230 TXV 33600 15.5 12.5 CX35-30/36B SL280UH090V48B 825920114ACXS036-230 TXV 33600 15.5 12.5 CX35-30/36B SL280UH090XV48B 825918914ACXS036-230 TXV 33400 15 12.5 CX35-30/36B SLP98UH070XV36B 825919914ACXS036-230 TXV 33000 14 11.5 CX35-30/36B 825917814ACXS036-230 TXV 33600 15.1 12.5 CX35-30/36C EL180UH090E60C 825921614ACXS036-230 TXV 33400 15.5 12.5 CX35-30/36C EL180UH110E60C 825921214ACXS036-230 TXV 33400 15.5 12.5 CX35-30/36C EL180UH110XE60C 825921714ACXS036-230 TXV 33200 15.1 12.5 CX35-30/36C EL195UH090XE48C 825920414ACXS036-230 TXV 33600 15.1 12.5 CX35-30/36C EL195UH110XE60C 825920614ACXS036-230 TXV 33200 15.1 12.5 CX35-30/36C EL296UH090XE48C 825921814ACXS036-230 TXV 33600 15.5 12.5 CX35-30/36C EL296UH090XV36C 825920814ACXS036-230 TXV 33400 15.5 12.5 CX35-30/36C EL296UH090XV48C 825920914ACXS036-230 TXV 33600 15.1 12.5 CX35-30/36C EL296UH110XE60C 825922014ACXS036-230 TXV 33600 15.5 12.5 CX35-30/36C EL296UH110XV48C 825921114ACXS036-230 TXV 33600 15.5 12.5 CX35-30/36C SLP98UH090XV36C 8259222NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 70

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS036-230 TXV 33400 15.5 12.5 CX35-30/36C SLP98UH090XV48C 825922314ACXS036-230 TXV 33800 15.5 12.5 CX35-30/36C SLP98UH110XV60C 825921414ACXS036-230 TXV 33000 14 11.5 CX35-30/36C 825920314ACXS036-230 TXV 34200 15.1 12.5 CX35-30A EL180UH045E36A 825914114ACXS036-230 TXV 34200 15.1 12.5 CX35-30A EL180UH045XE36A 825913914ACXS036-230 TXV 34400 15.1 12.5 CX35-30A SL280UH070V36A 825914314ACXS036-230 TXV 34400 15.1 12.5 CX35-30A SL280UH070XV36A 825913814ACXS036-230 TXV 34000 14.5 12 CX35-30A 825913614ACXS036-230 TXV 34400 15 12.5 CX35-30B EL180UH070E36B 825916414ACXS036-230 TXV 34400 15 12.5 CX35-30B EL180UH070XE36B 825915114ACXS036-230 TXV 34400 15.5 12.5 CX35-30B EL180UH090E48B 825916614ACXS036-230 TXV 34400 15.5 12.5 CX35-30B EL180UH090XE48B 825915314ACXS036-230 TXV 34000 14.5 12.2 CX35-30B EL195UH045XE36B 825916814ACXS036-230 TXV 34000 15.1 12.5 CX35-30B EL195UH070XE36B 825915614ACXS036-230 TXV 34000 14.5 12.2 CX35-30B EL296UH045XE36B 825915414ACXS036-230 TXV 34200 15.1 12.5 CX35-30B EL296UH045XV36B 825915814ACXS036-230 TXV 34000 15.1 12.5 CX35-30B EL296UH070XE36B 825914614ACXS036-230 TXV 34200 15.1 12.5 CX35-30B EL296UH070XV36B 825914814ACXS036-230 TXV 34400 15.5 12.5 CX35-30B SL280UH090V36B 825914914ACXS036-230 TXV 34400 15.5 12.5 CX35-30B SL280UH090V48B 825916114ACXS036-230 TXV 34400 15.5 12.5 CX35-30B SL280UH090XV48B 825916314ACXS036-230 TXV 34200 15.1 12.5 CX35-30B SLP98UH070XV36B 825915914ACXS036-230 TXV 34000 14.5 12 CX35-30B 825914414ACXS036-230 TXV 34400 15.1 12.5 CX35-36A EL180UH045E36A 825922714ACXS036-230 TXV 34400 15.1 12.5 CX35-36A EL180UH045XE36A 825923214ACXS036-230 TXV 34600 15.5 12.5 CX35-36A SL280UH070V36A 825922814ACXS036-230 TXV 34600 15.5 12.5 CX35-36A SL280UH070XV36A 825923014ACXS036-230 TXV 34200 14.5 12.2 CX35-36A 825922514ACXS036-230 TXV 34600 16 13 CX35-36B EL180UH070E36B 825925314ACXS036-230 TXV 34600 16 13 CX35-36B EL180UH070XE36B 825924214ACXS036-230 TXV 34600 16 13 CX35-36B EL180UH090E48B 825925514ACXS036-230 TXV 34600 16 13 CX35-36B EL180UH090XE48B 825924314ACXS036-230 TXV 34400 15 12.5 CX35-36B EL195UH045XE36B 825925714ACXS036-230 TXV 34400 15 12.5 CX35-36B EL195UH070XE36B 825924714ACXS036-230 TXV 34400 15 12.5 CX35-36B EL296UH045XE36B 825924514ACXS036-230 TXV 34600 15.5 12.5 CX35-36B EL296UH045XV36B 825924814ACXS036-230 TXV 34400 15 12.5 CX35-36B EL296UH070XE36B 825923514ACXS036-230 TXV 34600 15.5 12.5 CX35-36B EL296UH070XV36B 825923714ACXS036-230 TXV 34800 16 13 CX35-36B SL280UH090V36B 825923914ACXS036-230 TXV 34800 16 13 CX35-36B SL280UH090V48B 825925214ACXS036-230 TXV 34800 16 13 CX35-36B SL280UH090XV48B 825924014ACXS036-230 TXV 34600 15.5 12.5 CX35-36B SLP98UH070XV36B 825925014ACXS036-230 TXV 34200 14.25 12.2 CX35-36B 825923314ACXS036-230 TXV 34800 16 13 CX35-48B EL180UH070E36B 825926214ACXS036-230 TXV 34800 16 13 CX35-48B EL180UH070XE36B 825928214ACXS036-230 TXV 34800 16 13 CX35-48B EL180UH090E48B 825926314ACXS036-230 TXV 34800 16 13 CX35-48B EL180UH090XE48B 825926914ACXS036-230 TXV 34400 15 12.5 CX35-48B EL195UH045XE36B 825927114ACXS036-230 TXV 34600 15.1 12.5 CX35-48B EL195UH070XE36B 8259274NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 71

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS036-230 TXV 34400 15 12.5 CX35-48B EL296UH045XE36B 825927314ACXS036-230 TXV 34800 15.5 12.5 CX35-48B EL296UH045XV36B 825927814ACXS036-230 TXV 34600 15.1 12.5 CX35-48B EL296UH070XE36B 825927614ACXS036-230 TXV 34800 15.5 12.5 CX35-48B EL296UH070XV36B 825926514ACXS036-230 TXV 34800 16 13 CX35-48B SL280UH090V36B 825927914ACXS036-230 TXV 35000 16 13 CX35-48B SL280UH090V48B 825926014ACXS036-230 TXV 35000 16 13 CX35-48B SL280UH090XV48B 825928114ACXS036-230 TXV 34800 15.5 12.5 CX35-48B SLP98UH070XV36B 825926714ACXS036-230 TXV 34400 14.5 12.2 CX35-48B 825925814ACXS036-230 TXV 34800 16 13 CX35-48C EL180UH090E60C 825931414ACXS036-230 TXV 34800 16 13 CX35-48C EL180UH110E60C 825931614ACXS036-230 TXV 34800 16 13 CX35-48C EL180UH110XE60C 825929114ACXS036-230 TXV 34600 15.5 12.5 CX35-48C EL195UH090XE48C 825929214ACXS036-230 TXV 34800 16 13 CX35-48C EL195UH110XE60C 825929414ACXS036-230 TXV 34600 15.5 12.5 CX35-48C EL296UH090XE48C 825930214ACXS036-230 TXV 34800 16 13 CX35-48C EL296UH090XV36C 825929714ACXS036-230 TXV 34800 16 13 CX35-48C EL296UH090XV48C 825929814ACXS036-230 TXV 34600 16 13 CX35-48C EL296UH110XE60C 825930314ACXS036-230 TXV 35000 16 13 CX35-48C EL296UH110XV48C 825928614ACXS036-230 TXV 35200 16 13 CX35-48C EL296UH110XV60C 825930814ACXS036-230 TXV 35400 16 13 CX35-48C SL280UH090V60C 825930014ACXS036-230 TXV 35400 16 13 CX35-48C SL280UH090XV60C 825931014ACXS036-230 TXV 35200 16 13 CX35-48C SL280UH110V60C 825928914ACXS036-230 TXV 35200 16 13 CX35-48C SL280UH110XV60C 825931214ACXS036-230 TXV 34800 16 13 CX35-48C SLP98UH090XV36C 825930514ACXS036-230 TXV 34800 16 13 CX35-48C SLP98UH090XV48C 825930714ACXS036-230 TXV 35200 16 13 CX35-48C SLP98UH110XV60C 825928714ACXS036-230 TXV 34400 14.5 12.2 CX35-48C 825928414ACXS036-230 TXV 35200 16 13 CX35-49C EL180UH090E60C 825933014ACXS036-230 TXV 35000 16 13 CX35-49C EL180UH110E60C 825933714ACXS036-230 TXV 35000 16 13 CX35-49C EL180UH110XE60C 825933214ACXS036-230 TXV 34800 16 13 CX35-49C EL195UH090XE48C 825933814ACXS036-230 TXV 35200 16 13 CX35-49C EL195UH110XE60C 825934014ACXS036-230 TXV 34800 16 13 CX35-49C EL296UH090XE48C 825933314ACXS036-230 TXV 35200 16 13 CX35-49C EL296UH090XV36C 825934214ACXS036-230 TXV 35000 16 13 CX35-49C EL296UH090XV48C 825934314ACXS036-230 TXV 35200 16 13 CX35-49C EL296UH110XE60C 825932014ACXS036-230 TXV 35200 16 13 CX35-49C EL296UH110XV48C 825934514ACXS036-230 TXV 35600 16 13 CX35-49C EL296UH110XV60C 825932514ACXS036-230 TXV 35600 16 13 CX35-49C SL280UH090V60C 825932714ACXS036-230 TXV 35600 16 13 CX35-49C SL280UH090XV60C 825934714ACXS036-230 TXV 35400 16 13 CX35-49C SL280UH110V60C 825932814ACXS036-230 TXV 35400 16 13 CX35-49C SL280UH110XV60C 825934814ACXS036-230 TXV 35200 16 13 CX35-49C SLP98UH090XV36C 825932214ACXS036-230 TXV 35000 16 13 CX35-49C SLP98UH090XV48C 825932314ACXS036-230 TXV 35600 16 13 CX35-49C SLP98UH110XV60C 825933514ACXS036-230 TXV 34600 14.5 12.2 CX35-49C 825931814ACXS036-230 TXV 34800 16 13 CX35-50/60C EL180UH090E60C 825938014ACXS036-230 TXV 34800 16 13 CX35-50/60C EL180UH110E60C 8259356NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 72

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS036-230 TXV 34800 16 13 CX35-50/60C EL180UH110XE60C 825936714ACXS036-230 TXV 34600 15.5 12.5 CX35-50/60C EL195UH090XE48C 825936914ACXS036-230 TXV 34800 16 13 CX35-50/60C EL195UH110XE60C 825937214ACXS036-230 TXV 34600 15.5 12.5 CX35-50/60C EL296UH090XE48C 825937114ACXS036-230 TXV 34800 16 13 CX35-50/60C EL296UH090XV36C 825937514ACXS036-230 TXV 34800 16 13 CX35-50/60C EL296UH090XV48C 825936214ACXS036-230 TXV 34800 16 13 CX35-50/60C EL296UH110XE60C 825937414ACXS036-230 TXV 35000 16 13 CX35-50/60C EL296UH110XV48C 825936414ACXS036-230 TXV 35200 16 13 CX35-50/60C EL296UH110XV60C 825936114ACXS036-230 TXV 35200 16 13 CX35-50/60C SL280UH090V60C 825935214ACXS036-230 TXV 35200 16 13 CX35-50/60C SL280UH090XV60C 825937714ACXS036-230 TXV 35000 16 13 CX35-50/60C SL280UH110V60C 825935414ACXS036-230 TXV 35000 16 13 CX35-50/60C SL280UH110XV60C 825937814ACXS036-230 TXV 34800 16 13 CX35-50/60C SLP98UH090XV36C 825935714ACXS036-230 TXV 34800 16 13 CX35-50/60C SLP98UH090XV48C 825935914ACXS036-230 TXV 35200 16 13 CX35-50/60C SLP98UH110XV60C 825936614ACXS036-230 TXV 34200 14.5 12.2 CX35-50/60C 825935014ACXS036-230 TXV 34200 14.25 12.2 CX38-38A 1054815314ACXS042-230 RFC 41500 14 12.2 C35-49C 847104814ACXS042-230 RFC 41000 14 12.2 C35-60D 847105014ACXS042-230 RFC 41500 14 12.2 CH33-43B 845250014ACXS042-230 RFC 41500 14 12.2 CH33-43C 762821114ACXS042-230 RFC 42000 14 12.2 CH33-49 778298114ACXS042-230 RFC 41500 14 12.2 CH33-50/60C 778299214ACXS042-230 RFC 40500 14 12.2 CH35-51C 1051454514ACXS042-230 RFC 40500 14 12.2 CH35-60D 1051454614ACXS042-230 TXV 39500 14.5 12.2 C35-30/36B EL180UH090E48B 825824114ACXS042-230 TXV 39500 14.5 12.2 C35-30/36B EL180UH090XE48B 825823614ACXS042-230 TXV 39000 14 11.5 C35-30/36B EL296UH045XV36B 825823314ACXS042-230 TXV 39000 14 11.5 C35-30/36B EL296UH070XV36B 825823414ACXS042-230 TXV 39500 14.5 12.2 C35-30/36B SL280UH090V36B 825824314ACXS042-230 TXV 39500 14.5 12.2 C35-30/36B SL280UH090V48B 825823114ACXS042-230 TXV 39500 14.5 12.2 C35-30/36B SL280UH090XV48B 825823814ACXS042-230 TXV 39000 14 11.5 C35-30/36B SLP98UH070XV36B 825823914ACXS042-230 TXV 39500 14.5 12.2 C35-30/36C EL180UH090E60C 825825414ACXS042-230 TXV 39000 14.5 12.2 C35-30/36C EL180UH110E60C 825826414ACXS042-230 TXV 39000 14.5 12.2 C35-30/36C EL180UH110XE60C 825825614ACXS042-230 TXV 39000 14.5 12.2 C35-30/36C EL195UH090XE48C 825825114ACXS042-230 TXV 39500 14.5 12.2 C35-30/36C EL195UH110XE60C 825825314ACXS042-230 TXV 39000 14.5 12.2 C35-30/36C EL296UH090XE48C 825827414ACXS042-230 TXV 39000 14.5 12 C35-30/36C EL296UH090XV36C 825824514ACXS042-230 TXV 39000 14.5 12.2 C35-30/36C EL296UH090XV48C 825824614ACXS042-230 TXV 39500 14.5 12 C35-30/36C EL296UH090XV60C 825826614ACXS042-230 TXV 39500 14.5 12.2 C35-30/36C EL296UH110XE60C 825826314ACXS042-230 TXV 39500 14.5 12.2 C35-30/36C EL296UH110XV60C 825826814ACXS042-230 TXV 39500 14.5 12.2 C35-30/36C SL280UH090V60C 825826914ACXS042-230 TXV 39500 14.5 12.2 C35-30/36C SL280UH090XV60C 825827114ACXS042-230 TXV 39500 14.5 12.2 C35-30/36C SL280UH110V60C 825824914ACXS042-230 TXV 39500 14.5 12.2 C35-30/36C SL280UH110XV60C 8258273NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 73

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS042-230 TXV 39000 14.5 12 C35-30/36C SLP98UH090XV36C 825825814ACXS042-230 TXV 39000 14.5 12.2 C35-30/36C SLP98UH090XV48C 825825914ACXS042-230 TXV 39500 14.5 12 C35-30/36C SLP98UH090XV60C 825826114ACXS042-230 TXV 39500 14.5 12.2 C35-30/36C SLP98UH110XV60C 825824814ACXS042-230 TXV 41000 15.1 12.5 C35-36B EL180UH090E48B 825828814ACXS042-230 TXV 41000 15.1 12.5 C35-36B EL180UH090XE48B 825828314ACXS042-230 TXV 40500 14.5 12.2 C35-36B EL296UH045XV36B 825829014ACXS042-230 TXV 40500 14.5 12.2 C35-36B EL296UH070XV36B 825828514ACXS042-230 TXV 41000 15.1 12.5 C35-36B SL280UH090V36B 825827914ACXS042-230 TXV 41000 15.1 12.5 C35-36B SL280UH090V48B 825828614ACXS042-230 TXV 41000 15.1 12.5 C35-36B SL280UH090XV48B 825828114ACXS042-230 TXV 40500 14.5 12.2 C35-36B SLP98UH070XV36B 825827814ACXS042-230 TXV 40500 14.25 12 C35-36B 825827614ACXS042-230 TXV 41500 15.5 12.5 C35-48B EL180UH090E48B 825830114ACXS042-230 TXV 41500 15.5 12.5 C35-48B EL180UH090XE48B 825829814ACXS042-230 TXV 41000 14.5 12.2 C35-48B EL296UH045XV36B 825830314ACXS042-230 TXV 41000 14.5 12.2 C35-48B EL296UH070XV36B 825830514ACXS042-230 TXV 41000 15.1 12.5 C35-48B SL280UH090V36B 825829514ACXS042-230 TXV 41500 15.1 12.5 C35-48B SL280UH090V48B 825830014ACXS042-230 TXV 41500 15.1 12.5 C35-48B SL280UH090XV48B 825829614ACXS042-230 TXV 41000 14.5 12.2 C35-48B SLP98UH070XV36B 825829314ACXS042-230 TXV 41000 14.25 12 C35-48B 825829114ACXS042-230 TXV 41500 15.5 12.5 C35-48C EL180UH090E60C 825832814ACXS042-230 TXV 41500 15.5 12.5 C35-48C EL180UH110E60C 825831014ACXS042-230 TXV 41500 15.5 12.5 C35-48C EL180UH110XE60C 825833014ACXS042-230 TXV 41000 15.5 12.5 C35-48C EL195UH090XE48C 825831114ACXS042-230 TXV 41500 15.5 12.5 C35-48C EL195UH110XE60C 825831314ACXS042-230 TXV 41000 15.5 12.5 C35-48C EL296UH090XE48C 825833114ACXS042-230 TXV 41000 15.1 12.5 C35-48C EL296UH090XV36C 825833514ACXS042-230 TXV 41000 15.1 12.5 C35-48C EL296UH090XV48C 825833614ACXS042-230 TXV 41500 15.1 12.5 C35-48C EL296UH090XV60C 825832014ACXS042-230 TXV 41500 15.5 12.5 C35-48C EL296UH110XE60C 825833314ACXS042-230 TXV 41500 15.1 12.5 C35-48C EL296UH110XV48C 825831814ACXS042-230 TXV 41500 15.5 12.5 C35-48C EL296UH110XV60C 825832114ACXS042-230 TXV 41500 15.5 12.5 C35-48C SL280UH090V60C 825832514ACXS042-230 TXV 41500 15.5 12.5 C35-48C SL280UH090XV60C 825832314ACXS042-230 TXV 41500 15.5 12.5 C35-48C SL280UH110V60C 825832614ACXS042-230 TXV 41500 15.5 12.5 C35-48C SL280UH110XV60C 825830814ACXS042-230 TXV 41000 15.1 12.5 C35-48C SLP98UH090XV36C 825831514ACXS042-230 TXV 41000 15.1 12.5 C35-48C SLP98UH090XV48C 825831714ACXS042-230 TXV 41500 15.1 12.5 C35-48C SLP98UH090XV60C 825833814ACXS042-230 TXV 41500 15.5 12.5 C35-48C SLP98UH110XV60C 825834014ACXS042-230 TXV 41000 14.25 12 C35-48C 825830714ACXS042-230 TXV 42000 16 13 C35-49C EL180UH090E60C 825835514ACXS042-230 TXV 42000 16 13 C35-49C EL180UH110E60C 825836714ACXS042-230 TXV 42000 16 13 C35-49C EL180UH110XE60C 825835614ACXS042-230 TXV 41500 15.5 12.5 C35-49C EL195UH090XE48C 825836814ACXS042-230 TXV 42000 15.5 12.5 C35-49C EL195UH110XE60C 825834514ACXS042-230 TXV 41500 15.5 12.5 C35-49C EL296UH090XE48C 8258370NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 74

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS042-230 TXV 41500 15.5 12.5 C35-49C EL296UH090XV36C 825837214ACXS042-230 TXV 41500 15.5 12.5 C35-49C EL296UH090XV48C 825837314ACXS042-230 TXV 42000 15.5 12.5 C35-49C EL296UH090XV60C 825837514ACXS042-230 TXV 42000 15.5 12.5 C35-49C EL296UH110XE60C 825835814ACXS042-230 TXV 42000 15.5 12.5 C35-49C EL296UH110XV48C 825834614ACXS042-230 TXV 42000 15.5 12.5 C35-49C EL296UH110XV60C 825836014ACXS042-230 TXV 42000 16 13 C35-49C SL280UH090V60C 825834814ACXS042-230 TXV 42000 16 13 C35-49C SL280UH090XV60C 825836214ACXS042-230 TXV 42000 15.5 12.5 C35-49C SL280UH110V60C 825835014ACXS042-230 TXV 42000 15.5 12.5 C35-49C SL280UH110XV60C 825836314ACXS042-230 TXV 41500 15.5 12.5 C35-49C SLP98UH090XV36C 825835114ACXS042-230 TXV 41500 15.5 12.5 C35-49C SLP98UH090XV48C 825835314ACXS042-230 TXV 42000 15.5 12.5 C35-49C SLP98UH090XV60C 825836514ACXS042-230 TXV 42000 15.5 12.5 C35-49C SLP98UH110XV60C 825834314ACXS042-230 TXV 41500 14.25 12.2 C35-49C 825834114ACXS042-230 TXV 41000 15.5 12.5 C35-50/60C EL180UH090E60C 825840414ACXS042-230 TXV 41000 15.5 12.5 C35-50/60C EL180UH110E60C 825838514ACXS042-230 TXV 41000 15.5 12.5 C35-50/60C EL180UH110XE60C 825840614ACXS042-230 TXV 41000 15.1 12.5 C35-50/60C EL195UH090XE48C 825838714ACXS042-230 TXV 41000 15.1 12.5 C35-50/60C EL195UH110XE60C 825840814ACXS042-230 TXV 41000 15.1 12.5 C35-50/60C EL296UH090XE48C 825838814ACXS042-230 TXV 41000 15.1 12.5 C35-50/60C EL296UH090XV36C 825840914ACXS042-230 TXV 41000 15.1 12.5 C35-50/60C EL296UH090XV48C 825839014ACXS042-230 TXV 41000 15.1 12.5 C35-50/60C EL296UH090XV60C 825839414ACXS042-230 TXV 41000 15.1 12.5 C35-50/60C EL296UH110XE60C 825839114ACXS042-230 TXV 41000 15.1 12.5 C35-50/60C EL296UH110XV48C 825839614ACXS042-230 TXV 41000 15.1 12.5 C35-50/60C EL296UH110XV60C 825839314ACXS042-230 TXV 41500 15.1 12.5 C35-50/60C SL280UH090V60C 825839714ACXS042-230 TXV 41500 15.1 12.5 C35-50/60C SL280UH090XV60C 825837814ACXS042-230 TXV 41000 15.1 12.5 C35-50/60C SL280UH110V60C 825839914ACXS042-230 TXV 41000 15.1 12.5 C35-50/60C SL280UH110XV60C 825838014ACXS042-230 TXV 41000 15.1 12.5 C35-50/60C SLP98UH090XV36C 825840114ACXS042-230 TXV 41000 15.1 12.5 C35-50/60C SLP98UH090XV48C 825838214ACXS042-230 TXV 41000 15.1 12.5 C35-50/60C SLP98UH090XV60C 825840314ACXS042-230 TXV 41000 15.1 12.5 C35-50/60C SLP98UH110XV60C 825838314ACXS042-230 TXV 40500 14.25 12 C35-50/60C 825837714ACXS042-230 TXV 42000 16 13 C35-60C EL180UH090E60C 825841914ACXS042-230 TXV 42000 16 13 C35-60C EL180UH110E60C 825843914ACXS042-230 TXV 42000 16 13 C35-60C EL180UH110XE60C 825842114ACXS042-230 TXV 42000 16 13 C35-60C EL195UH090XE48C 825844114ACXS042-230 TXV 42000 16 13 C35-60C EL195UH110XE60C 825842314ACXS042-230 TXV 42000 16 13 C35-60C EL296UH090XE48C 825844314ACXS042-230 TXV 42000 15.5 12.5 C35-60C EL296UH090XV36C 825842414ACXS042-230 TXV 42000 16 13 C35-60C EL296UH090XV48C 825844414ACXS042-230 TXV 42000 15.5 12.5 C35-60C EL296UH090XV60C 825842614ACXS042-230 TXV 42000 16 13 C35-60C EL296UH110XE60C 825842914ACXS042-230 TXV 42000 16 13 C35-60C EL296UH110XV48C 825842814ACXS042-230 TXV 42000 16 13 C35-60C EL296UH110XV60C 825843114ACXS042-230 TXV 42000 16 13 C35-60C SL280UH090V60C 8258413NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 75

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS042-230 TXV 42000 16 13 C35-60C SL280UH090XV60C 825843214ACXS042-230 TXV 42000 16 13 C35-60C SL280UH110V60C 825841414ACXS042-230 TXV 42000 16 13 C35-60C SL280UH110XV60C 825843414ACXS042-230 TXV 42000 15.5 12.5 C35-60C SLP98UH090XV36C 825841614ACXS042-230 TXV 42000 16 13 C35-60C SLP98UH090XV48C 825843614ACXS042-230 TXV 42000 15.5 12.5 C35-60C SLP98UH090XV60C 825841814ACXS042-230 TXV 42000 16 13 C35-60C SLP98UH110XV60C 825843814ACXS042-230 TXV 42000 14.25 12.2 C35-60C 825841114ACXS042-230 TXV 42000 16 13 C35-60D EL180UH135E60D 825845114ACXS042-230 TXV 42000 15.5 12.5 C35-60D EL195UH135XE60D 825844814ACXS042-230 TXV 42000 15.5 12.5 C35-60D EL296UH135XE60D 825845214ACXS042-230 TXV 42000 16 13 C35-60D SL280UH135V60D 825844914ACXS042-230 TXV 41500 14.25 12.2 C35-60D 825844614ACXS042-230 TXV 41500 15.5 12.5 CBA27UHE-042 1025939314ACXS042-230 TXV 41500 15.5 12.5 CBA27UHE-048 1025939414ACXS042-230 TXV 41500 14 12.2 CBX25UH-042 762746414ACXS042-230 TXV 42000 14.5 12.5 CBX25UH-048 778293514ACXS042-230 TXV 42000 15.1 12.5 CBX25UHV-042 762746714ACXS042-230 TXV 42000 15.5 12.5 CBX25UHV-048 778293614ACXS042-230 TXV 41500 15.5 12.5 CBX27UH-042 762746114ACXS042-230 TXV 42000 15.1 12.5 CBX27UH-048 778293414ACXS042-230 TXV 40500 14 12.2 CBX32M-042 762747014ACXS042-230 TXV 41500 14.25 12.2 CBX32M-048 762747214ACXS042-230 TXV 42000 15.1 12.5 CBX32MV-048 762747514ACXS042-230 TXV 42000 15 12.5 CBX40UHV-042 762747714ACXS042-230 TXV 42000 15 12.5 CBX40UHV-048 778293714ACXS042-230 TXV 40500 15.1 12.5 CH23-51 EL180UH090E60C 762748014ACXS042-230 TXV 40000 15.1 12.5 CH23-51 EL180UH110E60C 778293814ACXS042-230 TXV 40000 15.1 12.5 CH23-51 EL180UH110XE60C 762748314ACXS042-230 TXV 40000 15.1 12.5 CH23-51 EL296UH090XV48C 778293914ACXS042-230 TXV 40000 15.1 12.5 CH23-51 EL296UH090XV60C 762748714ACXS042-230 TXV 40000 15.1 12.5 CH23-51 EL296UH110XV48C 762748914ACXS042-230 TXV 40000 15.1 12.5 CH23-51 EL296UH110XV60C 762749214ACXS042-230 TXV 40500 15.1 12.5 CH23-51 SL280UH090V60C 762749414ACXS042-230 TXV 40000 15.1 12.5 CH23-51 SL280UH110V60C 778294014ACXS042-230 TXV 40000 15.1 12.5 CH23-51 SL280UH110XV60C 778294114ACXS042-230 TXV 40000 15.1 12.5 CH23-51 SLP98UH090XV48C 762749814ACXS042-230 TXV 40000 15.1 12.5 CH23-51 SLP98UH090XV60C 778294214ACXS042-230 TXV 40000 15.1 12.5 CH23-51 SLP98UH110XV60C 762750114ACXS042-230 TXV 40500 15.5 12.5 CH23-65 EL180UH090E60C 778294314ACXS042-230 TXV 40500 15.5 12.5 CH23-65 EL180UH110E60C 762750414ACXS042-230 TXV 40500 15.5 12.5 CH23-65 EL180UH110XE60C 778294414ACXS042-230 TXV 40500 15.1 12.5 CH23-65 EL296UH090XV48C 778294514ACXS042-230 TXV 40500 15.1 12.5 CH23-65 EL296UH090XV60C 762750914ACXS042-230 TXV 40500 15.1 12.5 CH23-65 EL296UH110XV48C 778294614ACXS042-230 TXV 40500 15.1 12.5 CH23-65 EL296UH110XV60C 762751214ACXS042-230 TXV 41000 15.5 12.5 CH23-65 SL280UH090V60C 778294714ACXS042-230 TXV 40500 15.5 12.5 CH23-65 SL280UH110V60C 762751514ACXS042-230 TXV 40500 15.5 12.5 CH23-65 SL280UH110XV60C 7782948NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 76

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS042-230 TXV 40500 15.1 12.5 CH23-65 SLP98UH090XV48C 762751814ACXS042-230 TXV 40500 15.1 12.5 CH23-65 SLP98UH090XV60C 778294914ACXS042-230 TXV 40500 15.1 12.5 CH23-65 SLP98UH110XV60C 762752114ACXS042-230 TXV 40500 15.1 12.5 CH33-42B EL180UH090E48B 778295014ACXS042-230 TXV 40500 15.1 12.5 CH33-42B EL180UH090XE48B 762752414ACXS042-230 TXV 40000 14.5 12 CH33-42B EL296UH070XV36B 778295114ACXS042-230 TXV 40500 15 12.5 CH33-42B SL280UH090V36B 762752714ACXS042-230 TXV 40500 15 12.5 CH33-42B SL280UH090V48B 778295214ACXS042-230 TXV 40500 15 12.5 CH33-42B SL280UH090XV48B 762753014ACXS042-230 TXV 40000 14.5 12 CH33-42B SLP98UH070XV36B 778295314ACXS042-230 TXV 42000 15.5 12.5 CH33-43B EL180UH090E48B 856594914ACXS042-230 TXV 42000 15.5 12.5 CH33-43B EL180UH090XE48B 856595014ACXS042-230 TXV 41500 15 12.5 CH33-43B EL296UH045XV36B 762753314ACXS042-230 TXV 41500 15 12.5 CH33-43B EL296UH070XV36B 762753614ACXS042-230 TXV 42000 15.5 12.5 CH33-43B SL280UH090V36B 778295514ACXS042-230 TXV 42000 15.5 12.5 CH33-43B SL280UH090V48B 762753914ACXS042-230 TXV 42000 15.5 12.5 CH33-43B SL280UH090XV48B 778295614ACXS042-230 TXV 41500 15 12.5 CH33-43B SLP98UH070XV36B 778295414ACXS042-230 TXV 41500 14 12.2 CH33-43B 845249714ACXS042-230 TXV 41500 15.5 12.5 CH33-43C EL180UH090E60C 762754514ACXS042-230 TXV 41500 15.5 12.5 CH33-43C EL180UH110E60C 778295814ACXS042-230 TXV 41500 15.5 12.5 CH33-43C EL180UH110XE60C 762754814ACXS042-230 TXV 41000 15.5 12.5 CH33-43C EL195UH090XE48C 778295914ACXS042-230 TXV 41500 15.5 12.5 CH33-43C EL195UH110XE60C 762755114ACXS042-230 TXV 41000 15.5 12.5 CH33-43C EL296UH090XE48C 778296014ACXS042-230 TXV 41500 15.5 12.5 CH33-43C EL296UH090XV36C 762755414ACXS042-230 TXV 41500 15.5 12.5 CH33-43C EL296UH090XV48C 778296114ACXS042-230 TXV 41500 15.5 12.5 CH33-43C EL296UH090XV60C 762755714ACXS042-230 TXV 41500 15.5 12.5 CH33-43C EL296UH110XE60C 778296214ACXS042-230 TXV 41500 15.5 12.5 CH33-43C EL296UH110XV48C 762756014ACXS042-230 TXV 41500 15.5 12.5 CH33-43C EL296UH110XV60C 778296314ACXS042-230 TXV 42000 16 13 CH33-43C SL280UH090V60C 762756314ACXS042-230 TXV 42000 16 13 CH33-43C SL280UH090XV60C 778296414ACXS042-230 TXV 41500 15.5 12.5 CH33-43C SL280UH110V60C 762756614ACXS042-230 TXV 41500 15.5 12.5 CH33-43C SL280UH110XV60C 778296514ACXS042-230 TXV 41500 15.5 12.5 CH33-43C SLP98UH090XV36C 762756914ACXS042-230 TXV 41500 15.5 12.5 CH33-43C SLP98UH090XV48C 778296614ACXS042-230 TXV 41500 15.5 12.5 CH33-43C SLP98UH090XV60C 762757214ACXS042-230 TXV 41500 15.5 12.5 CH33-43C SLP98UH110XV60C 778296714ACXS042-230 TXV 41500 14 12.2 CH33-43C 778295714ACXS042-230 TXV 41000 15.1 12.5 CH33-44/48B EL180UH090E48B 762757514ACXS042-230 TXV 41000 15.1 12.5 CH33-44/48B EL180UH090XE48B 778296814ACXS042-230 TXV 40500 14.5 12.2 CH33-44/48B EL296UH070XV36B 762757814ACXS042-230 TXV 41000 15.1 12.5 CH33-44/48B SL280UH090V36B 778296914ACXS042-230 TXV 41000 15.1 12.5 CH33-44/48B SL280UH090V48B 762758114ACXS042-230 TXV 41000 15.1 12.5 CH33-44/48B SL280UH090XV48B 778297014ACXS042-230 TXV 40500 14.5 12.2 CH33-44/48B SLP98UH070XV36B 915035314ACXS042-230 TXV 41000 15 12.5 CH33-48 EL180UH090E48B 855265014ACXS042-230 TXV 41000 15.5 12.5 CH33-48C EL180UH090E60C 7782971NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 77

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS042-230 TXV 41000 15.5 12.5 CH33-48C EL180UH110E60C 762758714ACXS042-230 TXV 41000 15.5 12.5 CH33-48C EL180UH110XE60C 778297214ACXS042-230 TXV 41000 15.1 12.5 CH33-48C EL195UH090XE48C 762759014ACXS042-230 TXV 41500 15.1 12.5 CH33-48C EL195UH110XE60C 778297314ACXS042-230 TXV 41000 15.1 12.5 CH33-48C EL296UH090XE48C 762759314ACXS042-230 TXV 41000 15.1 12.5 CH33-48C EL296UH090XV36C 778297414ACXS042-230 TXV 41000 15.1 12.5 CH33-48C EL296UH090XV48C 762759614ACXS042-230 TXV 41500 15.1 12.5 CH33-48C EL296UH090XV60C 778297514ACXS042-230 TXV 41500 15.1 12.5 CH33-48C EL296UH110XE60C 762759914ACXS042-230 TXV 41000 15.1 12.5 CH33-48C EL296UH110XV48C 778297614ACXS042-230 TXV 41000 15.1 12.5 CH33-48C EL296UH110XV60C 762760214ACXS042-230 TXV 41500 15.5 12.5 CH33-48C SL280UH090V60C 778297714ACXS042-230 TXV 41500 15.5 12.5 CH33-48C SL280UH090XV60C 762760514ACXS042-230 TXV 41000 15.1 12.5 CH33-48C SL280UH110V60C 778297814ACXS042-230 TXV 41000 15.1 12.5 CH33-48C SL280UH110XV60C 762760814ACXS042-230 TXV 41000 15.1 12.5 CH33-48C SLP98UH090XV36C 778297914ACXS042-230 TXV 41000 15.1 12.5 CH33-48C SLP98UH090XV48C 762761114ACXS042-230 TXV 41500 15.1 12.5 CH33-48C SLP98UH090XV60C 778298014ACXS042-230 TXV 41000 15.1 12.5 CH33-48C SLP98UH110XV60C 762761514ACXS042-230 TXV 42000 15.5 12.5 CH33-49 EL180UH090E60C 778298214ACXS042-230 TXV 42000 15.5 12.5 CH33-49 EL180UH110E60C 762762114ACXS042-230 TXV 42000 15.5 12.5 CH33-49 EL180UH110XE60C 778298314ACXS042-230 TXV 41500 15.5 12.5 CH33-49 EL195UH090XE48C 762762414ACXS042-230 TXV 42000 15.5 12.5 CH33-49 EL195UH110XE60C 778298414ACXS042-230 TXV 41500 15.5 12.5 CH33-49 EL296UH090XE48C 762762814ACXS042-230 TXV 41500 15.5 12.5 CH33-49 EL296UH090XV36C 778298514ACXS042-230 TXV 42000 15.5 12.5 CH33-49 EL296UH090XV48C 762763114ACXS042-230 TXV 42000 15.5 12.5 CH33-49 EL296UH090XV60C 778298614ACXS042-230 TXV 42000 15.5 12.5 CH33-49 EL296UH110XE60C 762763414ACXS042-230 TXV 42000 15.5 12.5 CH33-49 EL296UH110XV48C 778298714ACXS042-230 TXV 42000 15.5 12.5 CH33-49 EL296UH110XV60C 762763714ACXS042-230 TXV 42000 15.5 12.5 CH33-49 SL280UH090V60C 778298814ACXS042-230 TXV 42000 15.5 12.5 CH33-49 SL280UH090XV60C 762764014ACXS042-230 TXV 42000 15.5 12.5 CH33-49 SL280UH110V60C 778298914ACXS042-230 TXV 42000 15.5 12.5 CH33-49 SL280UH110XV60C 762764414ACXS042-230 TXV 41500 15.5 12.5 CH33-49 SLP98UH090XV36C 778299014ACXS042-230 TXV 42000 15.5 12.5 CH33-49 SLP98UH090XV48C 762764714ACXS042-230 TXV 42000 15.5 12.5 CH33-49 SLP98UH090XV60C 778299114ACXS042-230 TXV 42000 15.5 12.5 CH33-49 SLP98UH110XV60C 762765014ACXS042-230 TXV 42000 14 12.2 CH33-49 762761814ACXS042-230 TXV 41500 15.5 12.5 CH33-50/60C EL180UH090E60C 778299314ACXS042-230 TXV 41500 15.5 12.5 CH33-50/60C EL180UH110E60C 762765814ACXS042-230 TXV 41500 15.5 12.5 CH33-50/60C EL180UH110XE60C 762766114ACXS042-230 TXV 41500 15.5 12.5 CH33-50/60C EL195UH090XE48C 762766314ACXS042-230 TXV 42000 15.5 12.5 CH33-50/60C EL195UH110XE60C 762766614ACXS042-230 TXV 41500 15.5 12.5 CH33-50/60C EL296UH090XE48C 762766914ACXS042-230 TXV 41500 15.1 12.5 CH33-50/60C EL296UH090XV36C 762767214ACXS042-230 TXV 41500 15.5 12.5 CH33-50/60C EL296UH090XV48C 778299414ACXS042-230 TXV 42000 15.1 12.5 CH33-50/60C EL296UH090XV60C 7627675NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 78

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS042-230 TXV 42000 15.5 12.5 CH33-50/60C EL296UH110XE60C 778299514ACXS042-230 TXV 41500 15.5 12.5 CH33-50/60C EL296UH110XV48C 762767814ACXS042-230 TXV 41500 15.5 12.5 CH33-50/60C EL296UH110XV60C 778299614ACXS042-230 TXV 42000 15.5 12.5 CH33-50/60C SL280UH090V60C 762768114ACXS042-230 TXV 42000 15.5 12.5 CH33-50/60C SL280UH090XV60C 778299714ACXS042-230 TXV 41500 15.5 12.5 CH33-50/60C SL280UH110V60C 762768414ACXS042-230 TXV 41500 15.5 12.5 CH33-50/60C SL280UH110XV60C 778299814ACXS042-230 TXV 41500 15.1 12.5 CH33-50/60C SLP98UH090XV36C 762768814ACXS042-230 TXV 41500 15.5 12.5 CH33-50/60C SLP98UH090XV48C 778299914ACXS042-230 TXV 42000 15.1 12.5 CH33-50/60C SLP98UH090XV60C 762769114ACXS042-230 TXV 41500 15.5 12.5 CH33-50/60C SLP98UH110XV60C 778300014ACXS042-230 TXV 41500 14 12.2 CH33-50/60C 762765414ACXS042-230 TXV 42000 15.5 12.5 CH35-42B EL180UH090E48B 762769414ACXS042-230 TXV 42000 15.5 12.5 CH35-42B EL180UH090XE48B 778300114ACXS042-230 TXV 42000 15.1 12.5 CH35-42B EL296UH045XV36B 762769714ACXS042-230 TXV 41500 15 12.5 CH35-42B EL296UH070XV36B 778300214ACXS042-230 TXV 42000 15.5 12.5 CH35-42B SL280UH090V36B 762770014ACXS042-230 TXV 42000 15.5 12.5 CH35-42B SL280UH090V48B 778300314ACXS042-230 TXV 42000 15.5 12.5 CH35-42B SL280UH090XV48B 762770414ACXS042-230 TXV 41500 15 12.5 CH35-42B SLP98UH070XV36B 778300414ACXS042-230 TXV 41500 14.25 12 CH35-42B 834199514ACXS042-230 TXV 41500 15.5 12.5 CH35-42C EL180UH090E60C 778300514ACXS042-230 TXV 41500 15.5 12.5 CH35-42C EL180UH110E60C 762771014ACXS042-230 TXV 41500 15.5 12.5 CH35-42C EL180UH110XE60C 778300614ACXS042-230 TXV 41500 15.5 12.5 CH35-42C EL195UH090XE48C 762771314ACXS042-230 TXV 42000 15.5 12.5 CH35-42C EL195UH110XE60C 778300714ACXS042-230 TXV 41500 15.5 12.5 CH35-42C EL296UH090XE48C 762771614ACXS042-230 TXV 41500 15.5 12.5 CH35-42C EL296UH090XV36C 778300814ACXS042-230 TXV 41500 15.5 12.5 CH35-42C EL296UH090XV48C 762771914ACXS042-230 TXV 42000 15.5 12.5 CH35-42C EL296UH090XV60C 778300914ACXS042-230 TXV 42000 15.5 12.5 CH35-42C EL296UH110XE60C 762772214ACXS042-230 TXV 41500 15.5 12.5 CH35-42C EL296UH110XV48C 778301014ACXS042-230 TXV 41500 15.5 12.5 CH35-42C EL296UH110XV60C 762772514ACXS042-230 TXV 42000 16 13 CH35-42C SL280UH090V60C 778301114ACXS042-230 TXV 42000 16 13 CH35-42C SL280UH090XV60C 762772814ACXS042-230 TXV 41500 15.5 12.5 CH35-42C SL280UH110V60C 778301214ACXS042-230 TXV 41500 15.5 12.5 CH35-42C SL280UH110XV60C 762773114ACXS042-230 TXV 41500 15.5 12.5 CH35-42C SLP98UH090XV36C 778301314ACXS042-230 TXV 41500 15.5 12.5 CH35-42C SLP98UH090XV48C 762773414ACXS042-230 TXV 42000 15.5 12.5 CH35-42C SLP98UH090XV60C 778301414ACXS042-230 TXV 41500 15.5 12.5 CH35-42C SLP98UH110XV60C 762773714ACXS042-230 TXV 41500 14 12.2 CH35-42C 762770714ACXS042-230 TXV 41500 15.5 12.5 CH35-48B EL180UH090E48B 778301514ACXS042-230 TXV 41500 15.5 12.5 CH35-48B EL180UH090XE48B 762774014ACXS042-230 TXV 41000 14.5 12.2 CH35-48B EL296UH045XV36B 778301614ACXS042-230 TXV 41000 14.5 12.2 CH35-48B EL296UH070XV36B 762774314ACXS042-230 TXV 41500 15.1 12.5 CH35-48B SL280UH090V36B 778301714ACXS042-230 TXV 41500 15.1 12.5 CH35-48B SL280UH090V48B 762774614ACXS042-230 TXV 41500 15.1 12.5 CH35-48B SL280UH090XV48B 7783018NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 79

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS042-230 TXV 41000 14.5 12.2 CH35-48B SLP98UH070XV36B 762774914ACXS042-230 TXV 41500 15.5 12.5 CH35-48C EL180UH090E60C 762775214ACXS042-230 TXV 41500 15.5 12.5 CH35-48C EL180UH110E60C 778302014ACXS042-230 TXV 41500 15.5 12.5 CH35-48C EL180UH110XE60C 762775514ACXS042-230 TXV 41000 15.1 12.5 CH35-48C EL195UH090XE48C 778302114ACXS042-230 TXV 41500 15.1 12.5 CH35-48C EL195UH110XE60C 762775814ACXS042-230 TXV 41000 15.1 12.5 CH35-48C EL296UH090XE48C 778302314ACXS042-230 TXV 41000 15.1 12.5 CH35-48C EL296UH090XV36C 762776114ACXS042-230 TXV 41500 15.1 12.5 CH35-48C EL296UH090XV48C 778302414ACXS042-230 TXV 41500 15.1 12.5 CH35-48C EL296UH090XV60C 762776414ACXS042-230 TXV 41500 15.1 12.5 CH35-48C EL296UH110XE60C 778302514ACXS042-230 TXV 41500 15.5 12.5 CH35-48C EL296UH110XV48C 762776714ACXS042-230 TXV 41500 15.1 12.5 CH35-48C EL296UH110XV60C 778302614ACXS042-230 TXV 41500 15.5 12.5 CH35-48C SL280UH090V60C 762777014ACXS042-230 TXV 41500 15.5 12.5 CH35-48C SL280UH090XV60C 778302714ACXS042-230 TXV 41500 15.1 12.5 CH35-48C SL280UH110V60C 762777314ACXS042-230 TXV 41500 15.1 12.5 CH35-48C SL280UH110XV60C 778302814ACXS042-230 TXV 41000 15.1 12.5 CH35-48C SLP98UH090XV36C 762777614ACXS042-230 TXV 41500 15.1 12.5 CH35-48C SLP98UH090XV48C 778302914ACXS042-230 TXV 41500 15.1 12.5 CH35-48C SLP98UH090XV60C 762777914ACXS042-230 TXV 41500 15.1 12.5 CH35-48C SLP98UH110XV60C 778303014ACXS042-230 TXV 41500 14 12.2 CH35-48C 778301914ACXS042-230 TXV 42000 15.5 12.5 CH35-51C EL180UH090E60C 778303114ACXS042-230 TXV 42000 15.5 12.5 CH35-51C EL180UH110E60C 762778614ACXS042-230 TXV 42000 15.5 12.5 CH35-51C EL180UH110XE60C 778303214ACXS042-230 TXV 41500 15.5 12.5 CH35-51C EL195UH090XE48C 762778914ACXS042-230 TXV 42000 15.5 12.5 CH35-51C EL195UH110XE60C 778303314ACXS042-230 TXV 41500 15.5 12.5 CH35-51C EL296UH090XE48C 762779214ACXS042-230 TXV 41500 15.5 12.5 CH35-51C EL296UH090XV36C 778303414ACXS042-230 TXV 42000 15.5 12.5 CH35-51C EL296UH090XV48C 762779514ACXS042-230 TXV 42000 15.5 12.5 CH35-51C EL296UH090XV60C 778303514ACXS042-230 TXV 42000 15.5 12.5 CH35-51C EL296UH110XE60C 762779814ACXS042-230 TXV 42000 15.5 12.5 CH35-51C EL296UH110XV48C 778303614ACXS042-230 TXV 42000 15.5 12.5 CH35-51C EL296UH110XV60C 762780114ACXS042-230 TXV 42000 15.5 12.5 CH35-51C SL280UH090V60C 778303714ACXS042-230 TXV 42000 15.5 12.5 CH35-51C SL280UH090XV60C 762780414ACXS042-230 TXV 42000 15.5 12.5 CH35-51C SL280UH110V60C 778303814ACXS042-230 TXV 42000 15.5 12.5 CH35-51C SL280UH110XV60C 762780714ACXS042-230 TXV 41500 15.5 12.5 CH35-51C SLP98UH090XV36C 778303914ACXS042-230 TXV 42000 15.5 12.5 CH35-51C SLP98UH090XV48C 762781014ACXS042-230 TXV 42000 15.5 12.5 CH35-51C SLP98UH090XV60C 778304014ACXS042-230 TXV 42000 15.5 12.5 CH35-51C SLP98UH110XV60C 762781314ACXS042-230 TXV 42000 14 12.2 CH35-51C 762778314ACXS042-230 TXV 40500 15.1 12.5 CR33-48 EL180DF110E60C 762781614ACXS042-230 TXV 40500 15.1 12.5 CR33-48 EL195DF090XE48C 778304214ACXS042-230 TXV 40500 15.1 12.5 CR33-48 EL195DF110XE60C 762781914ACXS042-230 TXV 40500 15.1 12.5 CR33-48 EL296DF090XE48C 778304414ACXS042-230 TXV 40500 15 12.2 CR33-48 EL296DF090XV60C 762782214ACXS042-230 TXV 40500 15.1 12.5 CR33-48 EL296DF110XE60C 7783045NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 80

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS042-230 TXV 40500 15.1 12.5 CR33-48 SL280DF090V60C 762782514ACXS042-230 TXV 40500 15.1 12.5 CR33-48 SL280DF110V60C 778304614ACXS042-230 TXV 40500 15 12.2 CR33-48 SLP98DF090XV60C 778304714ACXS042-230 TXV 40500 14.5 12.2 CR33-48B SL280DF090V48B 778304114ACXS042-230 TXV 41500 15.5 12.5 CR33-50/60 EL180DF110E60C 762783114ACXS042-230 TXV 41000 15.1 12.5 CR33-50/60 EL195DF090XE48C 778304814ACXS042-230 TXV 41500 15.5 12.5 CR33-50/60 EL195DF110XE60C 762783414ACXS042-230 TXV 41000 15.1 12.5 CR33-50/60 EL296DF090XE48C 778304914ACXS042-230 TXV 41500 15.1 12.5 CR33-50/60 EL296DF090XV60C 762783714ACXS042-230 TXV 41500 15.5 12.5 CR33-50/60 EL296DF110XE60C 778305014ACXS042-230 TXV 41500 15.5 12.5 CR33-50/60 EL296DF110XV60C 762784014ACXS042-230 TXV 41000 15.5 12.5 CR33-50/60 SL280DF090V60C 778305114ACXS042-230 TXV 41500 15.5 12.5 CR33-50/60 SL280DF110V60C 762784314ACXS042-230 TXV 41000 15.1 12.5 CR33-50/60 SLP98DF090XV36C 778305214ACXS042-230 TXV 41000 15.1 12.5 CR33-50/60 SLP98DF090XV48C 762784614ACXS042-230 TXV 41500 15.1 12.5 CR33-50/60 SLP98DF090XV60C 778305314ACXS042-230 TXV 41500 15.5 12.5 CR33-50/60 SLP98DF110XV60C 762784914ACXS042-230 TXV 39500 14.5 12.2 CX35-30/36B EL180UH090E48B 825846414ACXS042-230 TXV 39500 14.5 12.2 CX35-30/36B EL180UH090XE48B 825846614ACXS042-230 TXV 39000 14 11.5 CX35-30/36B EL296UH045XV36B 825846114ACXS042-230 TXV 39000 14 11.5 CX35-30/36B EL296UH070XV36B 825846214ACXS042-230 TXV 39500 14.5 12.2 CX35-30/36B SL280UH090V36B 825845414ACXS042-230 TXV 39500 14.5 12.2 CX35-30/36B SL280UH090V48B 825845914ACXS042-230 TXV 39500 14.5 12.2 CX35-30/36B SL280UH090XV48B 825845614ACXS042-230 TXV 39000 14 11.5 CX35-30/36B SLP98UH070XV36B 825845714ACXS042-230 TXV 39500 14.5 12.2 CX35-30/36C EL180UH090E60C 825849814ACXS042-230 TXV 39000 14.5 12.2 CX35-30/36C EL180UH110E60C 825848814ACXS042-230 TXV 39000 14.5 12.2 CX35-30/36C EL180UH110XE60C 825849014ACXS042-230 TXV 39000 14.5 12.2 CX35-30/36C EL195UH090XE48C 825849114ACXS042-230 TXV 39500 14.5 12.2 CX35-30/36C EL195UH110XE60C 825849314ACXS042-230 TXV 39000 14.5 12.2 CX35-30/36C EL296UH090XE48C 825847514ACXS042-230 TXV 39000 14.5 12 CX35-30/36C EL296UH090XV36C 825847714ACXS042-230 TXV 39000 14.5 12.2 CX35-30/36C EL296UH090XV48C 825849514ACXS042-230 TXV 39500 14.5 12 CX35-30/36C EL296UH090XV60C 825847914ACXS042-230 TXV 39500 14.5 12.2 CX35-30/36C EL296UH110XE60C 825849614ACXS042-230 TXV 39500 14.5 12.2 CX35-30/36C EL296UH110XV60C 825846714ACXS042-230 TXV 39500 14.5 12.2 CX35-30/36C SL280UH090V60C 825848014ACXS042-230 TXV 39500 14.5 12.2 CX35-30/36C SL280UH090XV60C 825846914ACXS042-230 TXV 39500 14.5 12.2 CX35-30/36C SL280UH110V60C 825848314ACXS042-230 TXV 39500 14.5 12.2 CX35-30/36C SL280UH110XV60C 825847014ACXS042-230 TXV 39000 14.5 12 CX35-30/36C SLP98UH090XV36C 825848514ACXS042-230 TXV 39000 14.5 12.2 CX35-30/36C SLP98UH090XV48C 825847214ACXS042-230 TXV 39500 14.5 12 CX35-30/36C SLP98UH090XV60C 825848614ACXS042-230 TXV 39500 14.5 12.2 CX35-30/36C SLP98UH110XV60C 825847414ACXS042-230 TXV 41000 15.1 12.5 CX35-36B EL180UH090E48B 825850314ACXS042-230 TXV 41000 15.1 12.5 CX35-36B EL180UH090XE48B 825851114ACXS042-230 TXV 40500 14.5 12.2 CX35-36B EL296UH045XV36B 825851314ACXS042-230 TXV 40500 14.5 12.2 CX35-36B EL296UH070XV36B 825850414ACXS042-230 TXV 41000 15.1 12.5 CX35-36B SL280UH090V36B 8258501NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 81

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS042-230 TXV 41000 15.1 12.5 CX35-36B SL280UH090V48B 825850614ACXS042-230 TXV 41000 15.1 12.5 CX35-36B SL280UH090XV48B 825850814ACXS042-230 TXV 40500 14.5 12.2 CX35-36B SLP98UH070XV36B 825850914ACXS042-230 TXV 40500 14.25 12 CX35-36B 825850014ACXS042-230 TXV 41500 15.5 12.5 CX35-48B EL180UH090E48B 825851614ACXS042-230 TXV 41500 15.5 12.5 CX35-48B EL180UH090XE48B 825852014ACXS042-230 TXV 41000 14.5 12.2 CX35-48B EL296UH045XV36B 825852114ACXS042-230 TXV 41000 14.5 12.2 CX35-48B EL296UH070XV36B 825852314ACXS042-230 TXV 41000 15.1 12.5 CX35-48B SL280UH090V36B 825852514ACXS042-230 TXV 41500 15.1 12.5 CX35-48B SL280UH090V48B 825852714ACXS042-230 TXV 41500 15.1 12.5 CX35-48B SL280UH090XV48B 825852814ACXS042-230 TXV 41000 14.5 12.2 CX35-48B SLP98UH070XV36B 825851814ACXS042-230 TXV 41000 14.25 12 CX35-48B 825851414ACXS042-230 TXV 41500 15.5 12.5 CX35-48C EL180UH090E60C 825854214ACXS042-230 TXV 41500 15.5 12.5 CX35-48C EL180UH110E60C 825855614ACXS042-230 TXV 41500 15.5 12.5 CX35-48C EL180UH110XE60C 825854314ACXS042-230 TXV 41000 15.5 12.5 CX35-48C EL195UH090XE48C 825855714ACXS042-230 TXV 41500 15.5 12.5 CX35-48C EL195UH110XE60C 825854514ACXS042-230 TXV 41000 15.5 12.5 CX35-48C EL296UH090XE48C 825855914ACXS042-230 TXV 41000 15.1 12.5 CX35-48C EL296UH090XV36C 825856114ACXS042-230 TXV 41000 15.1 12.5 CX35-48C EL296UH090XV48C 825856214ACXS042-230 TXV 41500 15.1 12.5 CX35-48C EL296UH090XV60C 825853214ACXS042-230 TXV 41500 15.5 12.5 CX35-48C EL296UH110XE60C 825856414ACXS042-230 TXV 41500 15.1 12.5 CX35-48C EL296UH110XV48C 825853314ACXS042-230 TXV 41500 15.5 12.5 CX35-48C EL296UH110XV60C 825854714ACXS042-230 TXV 41500 15.5 12.5 CX35-48C SL280UH090V60C 825853514ACXS042-230 TXV 41500 15.5 12.5 CX35-48C SL280UH090XV60C 825854914ACXS042-230 TXV 41500 15.5 12.5 CX35-48C SL280UH110V60C 825853714ACXS042-230 TXV 41500 15.5 12.5 CX35-48C SL280UH110XV60C 825855014ACXS042-230 TXV 41000 15.1 12.5 CX35-48C SLP98UH090XV36C 825853914ACXS042-230 TXV 41000 15.1 12.5 CX35-48C SLP98UH090XV48C 825855214ACXS042-230 TXV 41500 15.1 12.5 CX35-48C SLP98UH090XV60C 825854014ACXS042-230 TXV 41500 15.5 12.5 CX35-48C SLP98UH110XV60C 825855414ACXS042-230 TXV 41000 14.25 12 CX35-48C 825853014ACXS042-230 TXV 42000 16 13 CX35-49C EL180UH090E60C 825859214ACXS042-230 TXV 42000 16 13 CX35-49C EL180UH110E60C 825857214ACXS042-230 TXV 42000 16 13 CX35-49C EL180UH110XE60C 825859414ACXS042-230 TXV 41500 15.5 12.5 CX35-49C EL195UH090XE48C 825857414ACXS042-230 TXV 42000 15.5 12.5 CX35-49C EL195UH110XE60C 825859614ACXS042-230 TXV 41500 15.5 12.5 CX35-49C EL296UH090XE48C 825857614ACXS042-230 TXV 41500 15.5 12.5 CX35-49C EL296UH090XV36C 825859714ACXS042-230 TXV 41500 15.5 12.5 CX35-49C EL296UH090XV48C 825857714ACXS042-230 TXV 42000 15.5 12.5 CX35-49C EL296UH090XV60C 825859914ACXS042-230 TXV 42000 15.5 12.5 CX35-49C EL296UH110XE60C 825858214ACXS042-230 TXV 42000 15.5 12.5 CX35-49C EL296UH110XV48C 825856814ACXS042-230 TXV 42000 15.5 12.5 CX35-49C EL296UH110XV60C 825858414ACXS042-230 TXV 42000 16 13 CX35-49C SL280UH090V60C 825856914ACXS042-230 TXV 42000 16 13 CX35-49C SL280UH090XV60C 825858614ACXS042-230 TXV 42000 15.5 12.5 CX35-49C SL280UH110V60C 8258587NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 82

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS042-230 TXV 42000 15.5 12.5 CX35-49C SL280UH110XV60C 825858914ACXS042-230 TXV 41500 15.5 12.5 CX35-49C SLP98UH090XV36C 825859114ACXS042-230 TXV 41500 15.5 12.5 CX35-49C SLP98UH090XV48C 825857114ACXS042-230 TXV 42000 15.5 12.5 CX35-49C SLP98UH090XV60C 825857914ACXS042-230 TXV 42000 15.5 12.5 CX35-49C SLP98UH110XV60C 825858114ACXS042-230 TXV 41500 14.25 12.2 CX35-49C 825856614ACXS042-230 TXV 41000 15 12.5 CX35-50/60C EL180UH090E48B 1002583214ACXS042-230 TXV 41000 15.5 12.5 CX35-50/60C EL180UH090E60C 825862814ACXS042-230 TXV 41000 15.5 12.5 CX35-50/60C EL180UH110E60C 825862914ACXS042-230 TXV 41000 15.5 12.5 CX35-50/60C EL180UH110XE60C 825863114ACXS042-230 TXV 41000 15.1 12.5 CX35-50/60C EL195UH090XE48C 825863214ACXS042-230 TXV 41000 15.1 12.5 CX35-50/60C EL195UH110XE60C 825860514ACXS042-230 TXV 41000 15.1 12.5 CX35-50/60C EL296UH090XE48C 825861814ACXS042-230 TXV 41000 15.1 12.5 CX35-50/60C EL296UH090XV36C 825862014ACXS042-230 TXV 41000 15.1 12.5 CX35-50/60C EL296UH090XV48C 825862114ACXS042-230 TXV 41000 15.1 12.5 CX35-50/60C EL296UH090XV60C 825862314ACXS042-230 TXV 41000 15.1 12.5 CX35-50/60C EL296UH110XE60C 825862414ACXS042-230 TXV 41000 15.1 12.5 CX35-50/60C EL296UH110XV48C 825862614ACXS042-230 TXV 41000 15.1 12.5 CX35-50/60C EL296UH110XV60C 825861014ACXS042-230 TXV 41500 15.1 12.5 CX35-50/60C SL280UH090V60C 825860714ACXS042-230 TXV 41500 15.1 12.5 CX35-50/60C SL280UH090XV60C 825861214ACXS042-230 TXV 41000 15.1 12.5 CX35-50/60C SL280UH110V60C 825860914ACXS042-230 TXV 41000 15.1 12.5 CX35-50/60C SL280UH110XV60C 825861314ACXS042-230 TXV 41000 15.1 12.5 CX35-50/60C SLP98UH090XV36C 825860214ACXS042-230 TXV 41000 15.1 12.5 CX35-50/60C SLP98UH090XV48C 825861514ACXS042-230 TXV 41000 15.1 12.5 CX35-50/60C SLP98UH090XV60C 825860414ACXS042-230 TXV 41000 15.1 12.5 CX35-50/60C SLP98UH110XV60C 825861614ACXS042-230 TXV 40500 14.25 12 CX35-50/60C 825860114ACXS042-230 TXV 42000 16 13 CX35-60C EL180UH090E60C 825864914ACXS042-230 TXV 42000 16 13 CX35-60C EL180UH110E60C 825865914ACXS042-230 TXV 42000 16 13 CX35-60C EL180UH110XE60C 825865114ACXS042-230 TXV 42000 16 13 CX35-60C EL195UH090XE48C 825866014ACXS042-230 TXV 42000 16 13 CX35-60C EL195UH110XE60C 825863914ACXS042-230 TXV 42000 16 13 CX35-60C EL296UH090XE48C 825866214ACXS042-230 TXV 42000 15.5 12.5 CX35-60C EL296UH090XV36C 825864114ACXS042-230 TXV 42000 16 13 CX35-60C EL296UH090XV48C 825866414ACXS042-230 TXV 42000 15.5 12.5 CX35-60C EL296UH090XV60C 825864214ACXS042-230 TXV 42000 16 13 CX35-60C EL296UH110XE60C 825866614ACXS042-230 TXV 42000 16 13 CX35-60C EL296UH110XV60C 825864414ACXS042-230 TXV 42000 16 13 CX35-60C SL280UH090V60C 825865214ACXS042-230 TXV 42000 16 13 CX35-60C SL280UH090XV60C 825864614ACXS042-230 TXV 42000 16 13 CX35-60C SL280UH110V60C 825865414ACXS042-230 TXV 42000 16 13 CX35-60C SL280UH110XV60C 825864714ACXS042-230 TXV 42000 15.5 12.5 CX35-60C SLP98UH090XV36C 825865514ACXS042-230 TXV 42000 16 13 CX35-60C SLP98UH090XV48C 825863614ACXS042-230 TXV 42000 15.5 12.5 CX35-60C SLP98UH090XV60C 825865714ACXS042-230 TXV 42000 16 13 CX35-60C SLP98UH110XV60C 825863714ACXS042-230 TXV 42000 14.25 12.2 CX35-60C 825863414ACXS042-230 TXV 42000 16 13 CX35-60D EL180UH135E60D 8258669NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 83

AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACXS042-230 TXV 42000 15.5 12.5 CX35-60D EL195UH135XE60D 825867214ACXS042-230 TXV 42000 15.5 12.5 CX35-60D EL296UH135XE60D 825867114ACXS042-230 TXV 42000 16 13 CX35-60D SL280UH135V60D 825867414ACXS042-230 TXV 41500 14.5 12.2 CX35-60D 825866714ACXS042-230 TXV 41500 14.25 12.2 CX38-49C 10548593NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 84

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-018-230 RFC 18000 14 12.2 C35-18/24A 847100514ACX-018-230 RFC 18000 14 12.2 C35-18/24B 847100614ACX-018-230 RFC 19200 14.25 12.2 CH33-31A 718694214ACX-018-230 RFC 19100 14.25 12.2 CH33-31B 718694614ACX-018-230 RFC 19000 14 12.2 CR33-30/36A 718698314ACX-018-230 RFC 19000 14 12.2 CR33-30/36B 718698614ACX-018-230 TXV 19700 16 13 C35-24A EL180UH045E36A 826747414ACX-018-230 TXV 19700 16 13 C35-24A EL180UH045XE36A 826747314ACX-018-230 TXV 19200 14.25 12.2 C35-24A 826747214ACX-018-230 TXV 19500 15.5 12.5 C35-24B EL180UH070E36B 826747914ACX-018-230 TXV 19500 15.5 12.5 C35-24B EL180UH070XE36B 826747814ACX-018-230 TXV 18000 14.5 12.2 C35-24B EL195UH030XE24B 860882014ACX-018-230 TXV 18000 14.5 12.2 C35-24B EL195UH045XE24B 860882114ACX-018-230 TXV 20000 16 13 C35-24B EL195UH045XE36B 826748014ACX-018-230 TXV 20000 16 13 C35-24B EL296UH045XE36B 826748114ACX-018-230 TXV 20200 16 13 C35-24B EL296UH045XV36B 826748214ACX-018-230 TXV 20200 16 13 C35-24B EL296UH070XV36B 826747614ACX-018-230 TXV 20200 16 13 C35-24B SLP98UH070XV36B 826747714ACX-018-230 TXV 19200 14.25 12.2 C35-24B 826747514ACX-018-230 TXV 19900 16 13 C35-30A EL180UH045E36A 826748414ACX-018-230 TXV 19900 16 13 C35-30A EL180UH045XE36A 826748514ACX-018-230 TXV 19300 14.5 12.2 C35-30A 826748314ACX-018-230 TXV 19700 15.5 12.5 C35-30B EL180UH070E36B 826749014ACX-018-230 TXV 19700 15.5 12.5 C35-30B EL180UH070XE36B 826749114ACX-018-230 TXV 18000 14.5 12.2 C35-30B EL195UH030XE24B 860882214ACX-018-230 TXV 18000 14.5 12.2 C35-30B EL195UH045XE24B 860882314ACX-018-230 TXV 19800 16 13 C35-30B EL195UH045XE36B 826749214ACX-018-230 TXV 19800 16 13 C35-30B EL296UH045XE36B 826749314ACX-018-230 TXV 20400 16 13.5 C35-30B EL296UH045XV36B 826748814ACX-018-230 TXV 20400 16 13.5 C35-30B EL296UH070XV36B 826748914ACX-018-230 TXV 20400 16 13.5 C35-30B SLP98UH070XV36B 826748714ACX-018-230 TXV 19300 14.5 12.2 C35-30B 826748614ACX-018-230 TXV 19400 16 13 CBA27UHE-018 1025947714ACX-018-230 TXV 19400 16 13 CBA27UHE-024 1025937314ACX-018-230 TXV 19000 15.5 12.5 CBX25UHV-018 718692014ACX-018-230 TXV 19200 16 13 CBX25UHV-024 718692114ACX-018-230 TXV 19700 16 13 CBX27UH-018 718692214ACX-018-230 TXV 19700 16 13 CBX27UH-024 718692314ACX-018-230 TXV 19100 14.5 12.2 CBX32M-018/024 718692414ACX-018-230 TXV 19300 14.5 12.5 CBX32M-030 718692514ACX-018-230 TXV 19600 16 13 CBX32MV-018/024 718692614ACX-018-230 TXV 19700 16 13 CBX32MV-024/030 718692714ACX-018-230 TXV 19900 16 13 CBX40UHV-024 718692814ACX-018-230 TXV 19800 16 13 CBX40UHV-030 718692914ACX-018-230 TXV 19400 16 13 CH33-19 EL180UH045E36A 718723414ACX-018-230 TXV 19400 16 13 CH33-19 EL180UH045XE36A 718723314ACX-018-230 TXV 19300 16 13 CH33-24/30 EL180UH045E36A 718723914ACX-018-230 TXV 19300 16 13 CH33-24/30 EL180UH045XE36A 718723714ACX-018-230 TXV 19800 16 13 CH33-25A EL180UH045E36A 7186935NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 85

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-018-230 TXV 19800 16 13 CH33-25A EL180UH045XE36A 718693414ACX-018-230 TXV 19200 14.5 12.2 CH33-25A 718693314ACX-018-230 TXV 19400 15.5 12.5 CH33-25B EL180UH070E36B 718693814ACX-018-230 TXV 19400 15.5 12.5 CH33-25B EL180UH070XE36B 718693714ACX-018-230 TXV 19900 16 13 CH33-25B EL195UH045XE36B 718693914ACX-018-230 TXV 19900 16 13 CH33-25B EL296UH045XE36B 718694014ACX-018-230 TXV 20200 16 13 CH33-25B EL296UH045XV36B 718694114ACX-018-230 TXV 20200 16 13 CH33-31A EL180UH045E36A 718694514ACX-018-230 TXV 20200 16 13 CH33-31A EL180UH045XE36A 718694414ACX-018-230 TXV 19500 14.5 12.2 CH33-31A 718694314ACX-018-230 TXV 19900 16 13 CH33-31B EL180UH070E36B 718694914ACX-018-230 TXV 19900 16 13 CH33-31B EL180UH070XE36B 718694814ACX-018-230 TXV 18000 14.5 12.2 CH33-31B EL195UH030XE24B 860882414ACX-018-230 TXV 18000 14.5 12.2 CH33-31B EL195UH045XE24B 860882514ACX-018-230 TXV 19900 16 13 CH33-31B EL195UH045XE36B 718695014ACX-018-230 TXV 19900 16 13 CH33-31B EL296UH045XE36B 718695114ACX-018-230 TXV 20600 16 13.5 CH33-31B EL296UH045XV36B 718695214ACX-018-230 TXV 19500 14.5 12.2 CH33-31B 718694714ACX-018-230 TXV 19400 16 13 CH35-18A EL180UH045E36A 718695514ACX-018-230 TXV 19400 16 13 CH35-18A EL180UH045XE36A 718695414ACX-018-230 TXV 19900 16 13 CH35-24A EL180UH045E36A 718695814ACX-018-230 TXV 19900 16 13 CH35-24A EL180UH045XE36A 718695914ACX-018-230 TXV 19300 14.5 12.2 CH35-24A 718695714ACX-018-230 TXV 19500 15.5 12.5 CH35-24B EL180UH070E36B 718696114ACX-018-230 TXV 19500 15.5 12.5 CH35-24B EL180UH070XE36B 718696214ACX-018-230 TXV 19600 15.5 12.5 CH35-24B EL195UH045XE36B 718696314ACX-018-230 TXV 19600 15.5 12.5 CH35-24B EL296UH045XE36B 718696414ACX-018-230 TXV 20200 16 13 CH35-24B EL296UH045XV36B 718696514ACX-018-230 TXV 20200 16 13 CH35-30A EL180UH045E36A 718696914ACX-018-230 TXV 20200 16 13 CH35-30A EL180UH045XE36A 718696814ACX-018-230 TXV 19500 14.5 12.2 CH35-30A 718696714ACX-018-230 TXV 19900 16 13 CH35-30B EL180UH070E36B 718697214ACX-018-230 TXV 19900 16 13 CH35-30B EL180UH070XE36B 718697314ACX-018-230 TXV 18000 14.5 12.2 CH35-30B EL195UH030XE24B 860882614ACX-018-230 TXV 18000 14.5 12.2 CH35-30B EL195UH045XE24B 860882714ACX-018-230 TXV 19900 16 13 CH35-30B EL195UH045XE36B 718697414ACX-018-230 TXV 19900 16 13 CH35-30B EL296UH045XE36B 718697514ACX-018-230 TXV 20600 16 13.5 CH35-30B EL296UH045XV36B 718697614ACX-018-230 TXV 19500 14.5 12.2 CH35-30B 718697114ACX-018-230 TXV 19200 15.5 12.5 CR33-18 EL180DF045E36A 718697814ACX-018-230 TXV 18600 15.1 12.5 CR33-24A EL180DF045E36A 718697914ACX-018-230 TXV 18600 14.5 12.5 CR33-24B EL180DF070E36B 718698014ACX-018-230 TXV 19800 16 13 CR33-30/36A EL180DF045E36A 718698514ACX-018-230 TXV 19400 14.5 12.2 CR33-30/36A 718698414ACX-018-230 TXV 19800 15.5 12.5 CR33-30/36B EL180DF070E36B 718698814ACX-018-230 TXV 19400 14.5 12.2 CR33-30/36B 718698714ACX-018-230 TXV 18400 15 12.5 CX35-18/24A EL180UH045E36A 826749414ACX-018-230 TXV 18400 15 12.5 CX35-18/24A EL180UH045XE36A 826749514ACX-018-230 TXV 18500 14.5 12.2 CX35-18/24B EL180UH070E36B 8267499NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 86

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-018-230 TXV 18500 14.5 12.2 CX35-18/24B EL180UH070XE36B 826749614ACX-018-230 TXV 18600 15 12.5 CX35-18/24B EL195UH045XE36B 826749714ACX-018-230 TXV 18600 15 12.5 CX35-18/24B EL296UH045XE36B 826749814ACX-018-230 TXV 19700 16 13 CX35-24A EL180UH045E36A 826750114ACX-018-230 TXV 19700 16 13 CX35-24A EL180UH045XE36A 826750214ACX-018-230 TXV 19200 14.25 12.2 CX35-24A 826750014ACX-018-230 TXV 19500 15.5 12.5 CX35-24B EL180UH070E36B 826750714ACX-018-230 TXV 19500 15.5 12.5 CX35-24B EL180UH070XE36B 826750614ACX-018-230 TXV 18000 14.5 12.2 CX35-24B EL195UH030XE24B 860883614ACX-018-230 TXV 18000 14.5 12.2 CX35-24B EL195UH045XE24B 860883714ACX-018-230 TXV 20000 16 13 CX35-24B EL195UH045XE36B 826750814ACX-018-230 TXV 20000 16 13 CX35-24B EL296UH045XE36B 826750914ACX-018-230 TXV 20200 16 13 CX35-24B EL296UH045XV36B 826751014ACX-018-230 TXV 20200 16 13 CX35-24B EL296UH070XV36B 826750514ACX-018-230 TXV 20200 16 13 CX35-24B SLP98UH070XV36B 826750414ACX-018-230 TXV 19200 14.25 12.2 CX35-24B 826750314ACX-018-230 TXV 19900 16 13 CX35-30A EL180UH045E36A 826751214ACX-018-230 TXV 19900 16 13 CX35-30A EL180UH045XE36A 826751314ACX-018-230 TXV 19300 14.5 12.2 CX35-30A 826751114ACX-018-230 TXV 19700 15.5 12.5 CX35-30B EL180UH070E36B 826752014ACX-018-230 TXV 19700 15.5 12.5 CX35-30B EL180UH070XE36B 826752114ACX-018-230 TXV 18000 14.5 12.2 CX35-30B EL195UH030XE24B 860883814ACX-018-230 TXV 18000 14.5 12.2 CX35-30B EL195UH045XE24B 860883914ACX-018-230 TXV 19800 16 13 CX35-30B EL195UH045XE36B 826751614ACX-018-230 TXV 19800 16 13 CX35-30B EL296UH045XE36B 826751714ACX-018-230 TXV 20400 16 13.5 CX35-30B EL296UH045XV36B 826751814ACX-018-230 TXV 20400 16 13.5 CX35-30B EL296UH070XV36B 826751914ACX-018-230 TXV 20400 16 13.5 CX35-30B SLP98UH070XV36B 826751514ACX-018-230 TXV 19300 14.5 12.2 CX35-30B 826751414ACX-018-230 TXV 19200 14.25 12.2 CX38-25B 1054609714ACX-024-230 RFC 23400 14 12.2 C35-24A 847100714ACX-024-230 RFC 23600 14 12.2 C35-30A 847100814ACX-024-230 RFC 23600 14 12.2 C35-30B 847101014ACX-024-230 RFC 24000 14 12.2 C35-36A 847101214ACX-024-230 RFC 24000 14 12.2 C35-36B 847101414ACX-024-230 RFC 24000 14 12.2 CH33-25A 717536814ACX-024-230 RFC 24000 14.5 12.2 CH33-31A 717537014ACX-024-230 RFC 24000 14.5 12.2 CH33-31B 717537114ACX-024-230 RFC 23800 14 12.2 CH33-36C 717471214ACX-024-230 RFC 24000 14.2 12.2 CH33-42B 717538814ACX-024-230 RFC 24000 14.5 12.2 CH33-43B 717538914ACX-024-230 RFC 23400 14 12.2 CH35-24A 1051672414ACX-024-230 RFC 23600 14 12.2 CH35-30A 1051672514ACX-024-230 RFC 23600 14 12.2 CH35-30B 1051672614ACX-024-230 RFC 23800 14 12.2 CH35-36A 717541314ACX-024-230 RFC 24000 14 12.2 CH35-36C 717540714ACX-024-230 RFC 24000 14 12.2 CH35-42B 1051454714ACX-024-230 RFC 24000 14 12.2 CR33-30/36A 717539114ACX-024-230 RFC 24000 14 12.2 CR33-30/36B 7175392NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 87

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-024-230 RFC 24000 14 12.2 CR33-30/36C 717537314ACX-024-230 TXV 23400 15.1 12.5 C35-18/24B EL195UH030XE24B 860885214ACX-024-230 TXV 23400 15.1 12.5 C35-18/24B EL195UH045XE24B 860885314ACX-024-230 TXV 24000 16 13 C35-24A EL180UH045E36A 826849714ACX-024-230 TXV 24000 16 13 C35-24A EL180UH045XE36A 826849814ACX-024-230 TXV 24000 16 13 C35-24A SL280UH070V36A 826849514ACX-024-230 TXV 24000 16 13 C35-24A SL280UH070XV36A 826849614ACX-024-230 TXV 24000 14.25 12.2 C35-24A 826849414ACX-024-230 TXV 24000 16 13 C35-24B EL180UH070E36B 826850814ACX-024-230 TXV 24000 16 13 C35-24B EL180UH070XE36B 826850914ACX-024-230 TXV 24000 16 13 C35-24B EL195UH030XE24B 860885414ACX-024-230 TXV 24000 16 13 C35-24B EL195UH045XE24B 860885514ACX-024-230 TXV 24000 16 13 C35-24B EL195UH045XE36B 826850014ACX-024-230 TXV 24000 16 13 C35-24B EL195UH070XE36B 826850114ACX-024-230 TXV 24000 16 13 C35-24B EL296UH045XE36B 826850214ACX-024-230 TXV 24000 16 13 C35-24B EL296UH045XV36B 826850514ACX-024-230 TXV 24000 16 13 C35-24B EL296UH070XE36B 826850314ACX-024-230 TXV 24000 16 13 C35-24B EL296UH070XV36B 826850614ACX-024-230 TXV 24000 16 13 C35-24B SL280UH090V36B 826851014ACX-024-230 TXV 24000 16 13 C35-24B SL280UH090V48B 826851114ACX-024-230 TXV 24000 16 13 C35-24B SL280UH090XV48B 826850414ACX-024-230 TXV 24000 16 13 C35-24B SLP98UH070XV36B 826850714ACX-024-230 TXV 24000 14.25 12.2 C35-24B 826849914ACX-024-230 TXV 24000 16 13 C35-30/36A EL180UH045E36A 826853214ACX-024-230 TXV 24000 16 13 C35-30/36A EL180UH045XE36A 826853314ACX-024-230 TXV 24000 16 13 C35-30/36A SL280UH070V36A 826853014ACX-024-230 TXV 24000 16 13 C35-30/36A SL280UH070XV36A 826853114ACX-024-230 TXV 24000 16 13 C35-30/36B EL180UH070E36B 826854314ACX-024-230 TXV 24000 16 13 C35-30/36B EL180UH070XE36B 826854414ACX-024-230 TXV 24000 15.5 12.5 C35-30/36B EL195UH030XE24B 860885614ACX-024-230 TXV 24000 15.5 12.5 C35-30/36B EL195UH045XE24B 860885714ACX-024-230 TXV 23400 15.5 12.5 C35-30/36B EL195UH045XE36B 826854514ACX-024-230 TXV 23600 16 13 C35-30/36B EL195UH070XE36B 826853414ACX-024-230 TXV 23400 15.5 12.5 C35-30/36B EL296UH045XE36B 826853514ACX-024-230 TXV 24000 16 13 C35-30/36B EL296UH045XV36B 826853714ACX-024-230 TXV 23600 16 13 C35-30/36B EL296UH070XE36B 826853614ACX-024-230 TXV 24000 16 13 C35-30/36B EL296UH070XV36B 826853814ACX-024-230 TXV 24000 16 13 C35-30/36B SL280UH090V36B 826854014ACX-024-230 TXV 24000 16 13 C35-30/36B SL280UH090V48B 826854114ACX-024-230 TXV 24000 16 13 C35-30/36B SL280UH090XV48B 826854214ACX-024-230 TXV 24000 16 13 C35-30/36B SLP98UH070XV36B 826853914ACX-024-230 TXV 24000 16 13 C35-30/36C EL296UH090XV36C 826854614ACX-024-230 TXV 24000 16 13 C35-30/36C SLP98UH090XV36C 826854714ACX-024-230 TXV 24000 16 13 C35-30A EL180UH045E36A 826851314ACX-024-230 TXV 24000 16 13 C35-30A EL180UH045XE36A 826851414ACX-024-230 TXV 24000 16 13 C35-30A SL280UH070V36A 826851514ACX-024-230 TXV 24000 16 13 C35-30A SL280UH070XV36A 826851614ACX-024-230 TXV 24000 14.5 12.2 C35-30A 826851214ACX-024-230 TXV 24000 16 13 C35-30B EL180UH070E36B 8268529NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 88

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-024-230 TXV 24000 16 13 C35-30B EL180UH070XE36B 826852014ACX-024-230 TXV 24000 16 13 C35-30B EL195UH030XE24B 860885814ACX-024-230 TXV 24000 16 13 C35-30B EL195UH045XE24B 860885914ACX-024-230 TXV 24000 16 13 C35-30B EL195UH045XE36B 826852114ACX-024-230 TXV 24000 16 13 C35-30B EL195UH070XE36B 826852214ACX-024-230 TXV 24000 16 13 C35-30B EL296UH045XE36B 826852314ACX-024-230 TXV 24000 16 13 C35-30B EL296UH045XV36B 826852514ACX-024-230 TXV 24000 16 13 C35-30B EL296UH070XE36B 826852414ACX-024-230 TXV 24000 16 13 C35-30B EL296UH070XV36B 826851814ACX-024-230 TXV 24000 16 13 C35-30B SL280UH090V36B 826852614ACX-024-230 TXV 24000 16 13 C35-30B SL280UH090V48B 826852714ACX-024-230 TXV 24000 16 13 C35-30B SL280UH090XV48B 826852814ACX-024-230 TXV 24000 16 13 C35-30B SLP98UH070XV36B 826851914ACX-024-230 TXV 24000 14.5 12.2 C35-30B 826851714ACX-024-230 TXV 24000 16 13 C35-36A EL180UH045E36A 826855114ACX-024-230 TXV 24000 16 13 C35-36A EL180UH045XE36A 826855214ACX-024-230 TXV 24000 16 13.5 C35-36A SL280UH070V36A 826854914ACX-024-230 TXV 24000 16 13.5 C35-36A SL280UH070XV36A 826855014ACX-024-230 TXV 24000 14.5 12.5 C35-36A 826854814ACX-024-230 TXV 24000 16 13.5 C35-36B EL180UH070E36B 826856314ACX-024-230 TXV 24000 16 13.5 C35-36B EL180UH070XE36B 826856414ACX-024-230 TXV 24000 16 13 C35-36B EL195UH030XE24B 860886014ACX-024-230 TXV 24000 16 13 C35-36B EL195UH045XE24B 860886114ACX-024-230 TXV 24000 16 13 C35-36B EL195UH045XE36B 826856514ACX-024-230 TXV 24000 16 13 C35-36B EL195UH070XE36B 826855414ACX-024-230 TXV 24000 16 13 C35-36B EL296UH045XE36B 826855514ACX-024-230 TXV 24000 16 13 C35-36B EL296UH045XV36B 826855714ACX-024-230 TXV 24000 16 13 C35-36B EL296UH070XE36B 826855614ACX-024-230 TXV 24000 16 13 C35-36B EL296UH070XV36B 826855814ACX-024-230 TXV 24000 16 13.5 C35-36B SL280UH090V36B 826856014ACX-024-230 TXV 24000 16 13 C35-36B SL280UH090V48B 826856114ACX-024-230 TXV 24000 16 13 C35-36B SL280UH090XV48B 826856214ACX-024-230 TXV 24000 16 13 C35-36B SLP98UH070XV36B 826855914ACX-024-230 TXV 24000 14.5 12.5 C35-36B 826855314ACX-024-230 TXV 24000 16 13 CBA27UHE-024 1025937414ACX-024-230 TXV 24000 16 13 CBA27UHE-030 1025937514ACX-024-230 TXV 23600 14.5 12.2 CBX25UH-024 717461314ACX-024-230 TXV 23800 14.5 12.2 CBX25UH-030 717461414ACX-024-230 TXV 24000 14.5 12.2 CBX25UH-036 717461514ACX-024-230 TXV 24000 16 13 CBX25UHV-024 717461614ACX-024-230 TXV 24000 16 13 CBX25UHV-030 717461714ACX-024-230 TXV 24000 16 13 CBX25UHV-036 717461814ACX-024-230 TXV 24000 16 13 CBX27UH-024 717461914ACX-024-230 TXV 24000 16 13 CBX27UH-030 717462014ACX-024-230 TXV 23800 14.5 12.2 CBX32M-018/024 717462114ACX-024-230 TXV 24000 15.1 12.5 CBX32M-030 717462214ACX-024-230 TXV 24000 15.5 12.5 CBX32MV-018/024 717462314ACX-024-230 TXV 24000 16 13 CBX32MV-024/030 717462414ACX-024-230 TXV 24000 16 13 CBX40UHV-024 8560058NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 89

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-024-230 TXV 22800 15.1 12.5 CH23-31 EL180UH045E36A 717462614ACX-024-230 TXV 22800 15.1 12.5 CH23-31 EL180UH045XE36A 717462714ACX-024-230 TXV 23200 15.5 12.5 CH23-31 EL180UH070E36B 717462814ACX-024-230 TXV 23200 15.5 12.5 CH23-31 EL180UH070XE36B 717462914ACX-024-230 TXV 22800 14.5 12.5 CH23-31 EL195UH030XE24B 860886214ACX-024-230 TXV 22800 14.5 12.5 CH23-31 EL195UH045XE24B 860886314ACX-024-230 TXV 23000 15.1 12.5 CH23-31 EL195UH045XE36B 717463014ACX-024-230 TXV 23000 15.1 12.5 CH23-31 EL195UH070XE36B 717463114ACX-024-230 TXV 23000 15.1 12.5 CH23-31 EL296UH045XE36B 717463214ACX-024-230 TXV 23200 15.5 12.5 CH23-31 EL296UH045XV36B 717463414ACX-024-230 TXV 23000 15.1 12.5 CH23-31 EL296UH070XE36B 717463314ACX-024-230 TXV 23200 15.5 13 CH23-31 EL296UH070XV36B 717463514ACX-024-230 TXV 23400 15.1 13 CH23-31 SL280UH070V36A 717536514ACX-024-230 TXV 23400 16 13 CH23-31 SL280UH070XV36A 717536614ACX-024-230 TXV 23200 16 13 CH23-31 SL280UH090V36B 717462514ACX-024-230 TXV 23200 15.5 13 CH23-31 SLP98UH070XV36B 717463614ACX-024-230 TXV 24000 16 13 CH23-41 EL180UH045E36A 717464114ACX-024-230 TXV 24000 16 13 CH23-41 EL180UH045XE36A 717464214ACX-024-230 TXV 24000 16 13 CH23-41 EL180UH070E36B 717464314ACX-024-230 TXV 24000 16 13 CH23-41 EL180UH070XE36B 717464414ACX-024-230 TXV 24000 15.5 12.5 CH23-41 EL195UH030XE24B 860886414ACX-024-230 TXV 24000 15.5 12.5 CH23-41 EL195UH045XE24B 860886514ACX-024-230 TXV 24000 16 13 CH23-41 EL195UH045XE36B 717464514ACX-024-230 TXV 24000 16 13 CH23-41 EL195UH070XE36B 717464614ACX-024-230 TXV 24000 16 13 CH23-41 EL296UH045XE36B 717464714ACX-024-230 TXV 24000 16 13 CH23-41 EL296UH045XV36B 717464914ACX-024-230 TXV 24000 16 13 CH23-41 EL296UH070XE36B 717464814ACX-024-230 TXV 24000 16 13 CH23-41 EL296UH070XV36B 717465014ACX-024-230 TXV 24000 16 13 CH23-41 SL280UH070V36A 717463914ACX-024-230 TXV 24000 16 13 CH23-41 SL280UH070XV36A 717536714ACX-024-230 TXV 24000 16 13 CH23-41 SL280UH090V36B 717464014ACX-024-230 TXV 24000 16 13 CH23-41 SLP98UH070XV36B 717465114ACX-024-230 TXV 23800 15.5 12.5 CH33-19 EL180UH045E36A 717465514ACX-024-230 TXV 23800 15.5 12.5 CH33-19 EL180UH045XE36A 717465614ACX-024-230 TXV 24000 15.1 13 CH33-19 SL280UH070V36A 717465314ACX-024-230 TXV 24000 15.1 13 CH33-19 SL280UH070XV36A 717465414ACX-024-230 TXV 23800 15.5 12.5 CH33-24/30 EL180UH045E36A 717466014ACX-024-230 TXV 23800 15.5 12.5 CH33-24/30 EL180UH045XE36A 717466114ACX-024-230 TXV 23800 15.1 13 CH33-24/30 SL280UH070V36A 717465814ACX-024-230 TXV 23800 15.1 13 CH33-24/30 SL280UH070XV36A 717465914ACX-024-230 TXV 24000 16 13 CH33-25A EL180UH045E36A 717466514ACX-024-230 TXV 24000 16 13 CH33-25A EL180UH045XE36A 717466614ACX-024-230 TXV 24000 16 13 CH33-25A SL280UH070V36A 717466314ACX-024-230 TXV 24000 16 13 CH33-25A SL280UH070XV36A 717466414ACX-024-230 TXV 24000 14.5 12.2 CH33-25A 717466214ACX-024-230 TXV 24000 16 13 CH33-25B EL180UH070E36B 717466914ACX-024-230 TXV 24000 16 13 CH33-25B EL180UH070XE36B 717467014ACX-024-230 TXV 24000 15.5 12.5 CH33-25B EL195UH030XE24B 860886614ACX-024-230 TXV 24000 15.5 12.5 CH33-25B EL195UH045XE24B 8608867NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 90

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-024-230 TXV 24000 16 13 CH33-25B EL195UH045XE36B 717467114ACX-024-230 TXV 24000 16 13 CH33-25B EL195UH070XE36B 717467214ACX-024-230 TXV 24000 16 13 CH33-25B EL296UH045XE36B 717467314ACX-024-230 TXV 24000 16 13 CH33-25B EL296UH045XV36B 717467514ACX-024-230 TXV 24000 16 13 CH33-25B EL296UH070XE36B 717467414ACX-024-230 TXV 24000 16 13 CH33-25B EL296UH070XV36B 717467614ACX-024-230 TXV 24000 16 13 CH33-25B SL280UH090V36B 717466814ACX-024-230 TXV 24000 16 13 CH33-25B SLP98UH070XV36B 717467714ACX-024-230 TXV 24000 16 13 CH33-31A EL180UH045E36A 717468114ACX-024-230 TXV 24000 16 13 CH33-31A EL180UH045XE36A 717468214ACX-024-230 TXV 24000 16 13 CH33-31A SL280UH070V36A 717467914ACX-024-230 TXV 24000 16 13 CH33-31A SL280UH070XV36A 717468014ACX-024-230 TXV 24000 14.5 12.5 CH33-31A 717467814ACX-024-230 TXV 24000 16 13.5 CH33-31B EL180UH070E36B 717468514ACX-024-230 TXV 24000 16 13.5 CH33-31B EL180UH070XE36B 717468614ACX-024-230 TXV 24000 16 13 CH33-31B EL195UH030XE24B 860886814ACX-024-230 TXV 24000 16 13 CH33-31B EL195UH045XE24B 860886914ACX-024-230 TXV 24000 16 13 CH33-31B EL195UH045XE36B 717468714ACX-024-230 TXV 24000 16 13 CH33-31B EL195UH070XE36B 717468814ACX-024-230 TXV 24000 16 13 CH33-31B EL296UH045XE36B 717468914ACX-024-230 TXV 24000 16 13 CH33-31B EL296UH045XV36B 717469114ACX-024-230 TXV 24000 16 13 CH33-31B EL296UH070XE36B 717469014ACX-024-230 TXV 24000 16 13 CH33-31B EL296UH070XV36B 717469214ACX-024-230 TXV 24000 16 13.5 CH33-31B SL280UH090V36B 717468414ACX-024-230 TXV 24000 16 13 CH33-31B SLP98UH070XV36B 717469314ACX-024-230 TXV 24000 14.5 12.5 CH33-31B 717468314ACX-024-230 TXV 24000 16 13 CH33-36A EL180UH045E36A 717469814ACX-024-230 TXV 24000 16 13 CH33-36A EL180UH045XE36A 717469914ACX-024-230 TXV 24000 16 13 CH33-36A SL280UH070V36A 717469614ACX-024-230 TXV 24000 16 13 CH33-36A SL280UH070XV36A 717469714ACX-024-230 TXV 24000 16 13 CH33-36B EL180UH070E36B 717470314ACX-024-230 TXV 24000 16 13 CH33-36B EL180UH070XE36B 717470414ACX-024-230 TXV 24000 15.5 12.5 CH33-36B EL195UH030XE24B 860887014ACX-024-230 TXV 24000 15.5 12.5 CH33-36B EL195UH045XE24B 860887114ACX-024-230 TXV 24000 16 13 CH33-36B EL195UH045XE36B 717470514ACX-024-230 TXV 24000 16 13 CH33-36B EL195UH070XE36B 717470614ACX-024-230 TXV 24000 16 13 CH33-36B EL296UH045XE36B 717470714ACX-024-230 TXV 24000 16 13 CH33-36B EL296UH045XV36B 717470914ACX-024-230 TXV 24000 16 13 CH33-36B EL296UH070XE36B 717470814ACX-024-230 TXV 24000 16 13 CH33-36B EL296UH070XV36B 717471014ACX-024-230 TXV 24000 16 13 CH33-36B SL280UH090V36B 717470214ACX-024-230 TXV 24000 16 13 CH33-36B SLP98UH070XV36B 717471114ACX-024-230 TXV 24000 16 13 CH33-36C EL296UH090XV36C 717471414ACX-024-230 TXV 24000 16 13 CH33-36C SLP98UH090XV36C 717471514ACX-024-230 TXV 24000 16 13 CH33-42 EL195UH030XE24B 860887214ACX-024-230 TXV 24000 16 13 CH33-42 EL195UH045XE24B 860887314ACX-024-230 TXV 24000 16 13 CH33-43B EL195UH030XE24B 860887414ACX-024-230 TXV 24000 16 13 CH33-43B EL195UH045XE24B 860887514ACX-024-230 TXV 24000 16 13 CH33-43B EL195UH045XE36B 8237805NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 91

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-024-230 TXV 24000 16 13 CH35-18A EL180UH045E36A 717471914ACX-024-230 TXV 24000 16 13 CH35-18A EL180UH045XE36A 717472014ACX-024-230 TXV 24000 16 13 CH35-18A SL280UH070V36A 717471714ACX-024-230 TXV 24000 16 13 CH35-18A SL280UH070XV36A 717471814ACX-024-230 TXV 24000 16 13 CH35-24A EL180UH045E36A 717472514ACX-024-230 TXV 24000 16 13 CH35-24A EL180UH045XE36A 717472614ACX-024-230 TXV 24000 16 13 CH35-24A SL280UH070V36A 717472314ACX-024-230 TXV 24000 16 13 CH35-24A SL280UH070XV36A 717472414ACX-024-230 TXV 23800 14.5 12.2 CH35-24A 717472214ACX-024-230 TXV 24000 16 13 CH35-24B EL180UH070E36B 717473014ACX-024-230 TXV 24000 16 13 CH35-24B EL180UH070XE36B 717473114ACX-024-230 TXV 24000 15.5 12.5 CH35-24B EL195UH030XE24B 860887614ACX-024-230 TXV 24000 15.5 12.5 CH35-24B EL195UH045XE24B 860887714ACX-024-230 TXV 24000 16 13 CH35-24B EL195UH045XE36B 717473214ACX-024-230 TXV 24000 16 13 CH35-24B EL195UH070XE36B 717473314ACX-024-230 TXV 24000 16 13 CH35-24B EL296UH045XV36B 717473414ACX-024-230 TXV 24000 16 13 CH35-24B EL296UH070XV36B 717473514ACX-024-230 TXV 24000 16 13 CH35-24B SL280UH090V36B 717472914ACX-024-230 TXV 24000 16 13 CH35-24B SLP98UH070XV36B 717473614ACX-024-230 TXV 24000 14.5 12.2 CH35-24B 717472814ACX-024-230 TXV 24000 16 13 CH35-30A EL180UH045E36A 717474114ACX-024-230 TXV 24000 16 13 CH35-30A EL180UH045XE36A 717474214ACX-024-230 TXV 24000 16 13 CH35-30A SL280UH070V36A 717473914ACX-024-230 TXV 24000 16 13 CH35-30A SL280UH070XV36A 717474014ACX-024-230 TXV 24000 15 12.5 CH35-30A 717473814ACX-024-230 TXV 24000 16 13.5 CH35-30B EL180UH070E36B 717474614ACX-024-230 TXV 24000 16 13.5 CH35-30B EL180UH070XE36B 717474714ACX-024-230 TXV 24000 16 13 CH35-30B EL195UH030XE24B 860887814ACX-024-230 TXV 24000 16 13 CH35-30B EL195UH045XE24B 860887914ACX-024-230 TXV 24000 16 13 CH35-30B EL195UH045XE36B 717474814ACX-024-230 TXV 24000 16 13 CH35-30B EL195UH070XE36B 717474914ACX-024-230 TXV 24000 16 13 CH35-30B EL296UH045XV36B 717475014ACX-024-230 TXV 24000 16 13 CH35-30B EL296UH070XV36B 717475114ACX-024-230 TXV 24000 16 13.5 CH35-30B SL280UH090V36B 717474514ACX-024-230 TXV 24000 16 13 CH35-30B SLP98UH070XV36B 717475214ACX-024-230 TXV 24000 14.5 12.5 CH35-30B 717474414ACX-024-230 TXV 24000 16 13 CH35-36A EL180UH045E36A 717475614ACX-024-230 TXV 24000 16 13 CH35-36A EL180UH045XE36A 717475714ACX-024-230 TXV 24000 16 13 CH35-36A SL280UH070V36A 717475414ACX-024-230 TXV 24000 16 13 CH35-36A SL280UH070XV36A 717475514ACX-024-230 TXV 23800 14.25 12.2 CH35-36A 717475314ACX-024-230 TXV 24000 16 13 CH35-36B EL180UH070E36B 717476014ACX-024-230 TXV 24000 16 13 CH35-36B EL180UH070XE36B 717476114ACX-024-230 TXV 24000 15.5 12.5 CH35-36B EL195UH030XE24B 860888014ACX-024-230 TXV 24000 15.5 12.5 CH35-36B EL195UH045XE24B 860888114ACX-024-230 TXV 24000 16 13 CH35-36B EL195UH045XE36B 717476214ACX-024-230 TXV 24000 16 13 CH35-36B EL195UH070XE36B 717476314ACX-024-230 TXV 24000 16 13 CH35-36B EL296UH045XV36B 717476414ACX-024-230 TXV 24000 16 13 CH35-36B EL296UH070XV36B 7174765NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 92

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-024-230 TXV 24000 16 13 CH35-36B SL280UH090V36B 717475914ACX-024-230 TXV 24000 16 13 CH35-36B SLP98UH070XV36B 717476614ACX-024-230 TXV 23800 14 12.2 CH35-36B 717475814ACX-024-230 TXV 24000 16 13 CH35-36C EL296UH090XV36C 717476814ACX-024-230 TXV 24000 16 13 CH35-36C SLP98UH090XV36C 717476914ACX-024-230 TXV 24000 14.25 12.2 CH35-36C 717476714ACX-024-230 TXV 23400 15.1 12.5 CR33-24A EL180DF045E36A 717477114ACX-024-230 TXV 23000 15.1 12.5 CR33-24A SL280DF070V36A 717477014ACX-024-230 TXV 23000 15.1 12.5 CR33-24B EL180DF070E36B 717477214ACX-024-230 TXV 22600 15 12.5 CR33-24B EL195DF045XE36B 717477314ACX-024-230 TXV 22800 15 12.5 CR33-24B EL195DF070XE48B 717477414ACX-024-230 TXV 22600 15 12.5 CR33-24B EL296DF045XE36B 717477514ACX-024-230 TXV 23000 15.1 12.5 CR33-24B EL296DF045XV36B 717477714ACX-024-230 TXV 22800 15 12.5 CR33-24B EL296DF070XE48B 717477614ACX-024-230 TXV 23400 15 12.5 CR33-24B EL296DF070XV48B 824714714ACX-024-230 TXV 23200 15.1 12.5 CR33-24B SLP98DF070XV36B 717477814ACX-024-230 TXV 24000 16 13 CR33-30/36A EL180DF045E36A 717478114ACX-024-230 TXV 24000 16 13 CR33-30/36A SL280DF070V36A 717478014ACX-024-230 TXV 24000 14.5 12.2 CR33-30/36A 717477914ACX-024-230 TXV 24000 16 13 CR33-30/36B EL180DF070E36B 717478314ACX-024-230 TXV 24000 16 13 CR33-30/36B EL195DF045XE36B 717478414ACX-024-230 TXV 24000 16 13 CR33-30/36B EL195DF070XE48B 717478514ACX-024-230 TXV 24000 16 13 CR33-30/36B EL296DF045XE36B 717478614ACX-024-230 TXV 24000 16 13 CR33-30/36B EL296DF045XV36B 717478914ACX-024-230 TXV 24000 16 13 CR33-30/36B EL296DF070XE48B 717478714ACX-024-230 TXV 24000 16 13 CR33-30/36B EL296DF070XV48B 717479014ACX-024-230 TXV 24000 16 13 CR33-30/36B SL280DF090V48B 717478814ACX-024-230 TXV 24000 16 13 CR33-30/36B SLP98DF070XV36B 717479114ACX-024-230 TXV 24000 14.5 12.2 CR33-30/36B 717478214ACX-024-230 TXV 24000 16 13 CR33-30/36C SLP98DF090XV36C 717479314ACX-024-230 TXV 24000 14.5 12.2 CR33-30/36C 717479214ACX-024-230 TXV 22800 15 12.5 CX35-18/24A EL180UH045E36A 826856614ACX-024-230 TXV 22800 15 12.5 CX35-18/24A EL180UH045XE36A 826856714ACX-024-230 TXV 23400 15.1 12.5 CX35-18/24B EL195UH030XE24B 860889414ACX-024-230 TXV 23400 15 12.5 CX35-18/24B EL195UH045XE24B 860889514ACX-024-230 TXV 24000 16 13 CX35-24A EL180UH045E36A 826856914ACX-024-230 TXV 24000 16 13 CX35-24A EL180UH045XE36A 826857014ACX-024-230 TXV 24000 16 13 CX35-24A SL280UH070V36A 826857114ACX-024-230 TXV 24000 16 13 CX35-24A SL280UH070XV36A 826857214ACX-024-230 TXV 24000 14.25 12.2 CX35-24A 826856814ACX-024-230 TXV 24000 16 13 CX35-24B EL180UH070E36B 826857814ACX-024-230 TXV 24000 16 13 CX35-24B EL180UH070XE36B 826857914ACX-024-230 TXV 24000 16 13 CX35-24B EL195UH030XE24B 860889614ACX-024-230 TXV 24000 16 13 CX35-24B EL195UH045XE24B 860889714ACX-024-230 TXV 24000 16 13 CX35-24B EL195UH045XE36B 826858014ACX-024-230 TXV 24000 16 13 CX35-24B EL195UH070XE36B 826858114ACX-024-230 TXV 24000 16 13 CX35-24B EL296UH045XE36B 826857414ACX-024-230 TXV 24000 16 13 CX35-24B EL296UH045XV36B 826858514ACX-024-230 TXV 24000 16 13 CX35-24B EL296UH070XE36B 8268575NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 93

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-024-230 TXV 24000 16 13 CX35-24B EL296UH070XV36B 826857614ACX-024-230 TXV 24000 16 13 CX35-24B SL280UH090V36B 826858214ACX-024-230 TXV 24000 16 13 CX35-24B SL280UH090V48B 826858314ACX-024-230 TXV 24000 16 13 CX35-24B SL280UH090XV48B 826858414ACX-024-230 TXV 24000 16 13 CX35-24B SLP98UH070XV36B 826857714ACX-024-230 TXV 24000 14.25 12.2 CX35-24B 826857314ACX-024-230 TXV 24000 16 13 CX35-30/36A EL180UH045E36A 826860714ACX-024-230 TXV 24000 16 13 CX35-30/36A EL180UH045XE36A 826860614ACX-024-230 TXV 24000 16 13 CX35-30/36A SL280UH070V36A 826860414ACX-024-230 TXV 24000 16 13 CX35-30/36A SL280UH070XV36A 826860514ACX-024-230 TXV 24000 16 13 CX35-30/36B EL180UH070E36B 826861314ACX-024-230 TXV 24000 16 13 CX35-30/36B EL180UH070XE36B 826861414ACX-024-230 TXV 24000 15.5 12.5 CX35-30/36B EL195UH030XE24B 860889814ACX-024-230 TXV 24000 15.5 12.5 CX35-30/36B EL195UH045XE24B 860889914ACX-024-230 TXV 23400 15.5 12.5 CX35-30/36B EL195UH045XE36B 826861514ACX-024-230 TXV 23600 16 13 CX35-30/36B EL195UH070XE36B 826861614ACX-024-230 TXV 23400 15.5 12.5 CX35-30/36B EL296UH045XE36B 826861714ACX-024-230 TXV 24000 16 13 CX35-30/36B EL296UH045XV36B 826860914ACX-024-230 TXV 23600 16 13 CX35-30/36B EL296UH070XE36B 826860814ACX-024-230 TXV 24000 16 13 CX35-30/36B EL296UH070XV36B 826861014ACX-024-230 TXV 24000 16 13 CX35-30/36B SL280UH090V36B 826861814ACX-024-230 TXV 24000 16 13 CX35-30/36B SL280UH090V48B 826861914ACX-024-230 TXV 24000 16 13 CX35-30/36B SL280UH090XV48B 826861214ACX-024-230 TXV 24000 16 13 CX35-30/36B SLP98UH070XV36B 826861114ACX-024-230 TXV 24000 16 13 CX35-30/36C EL296UH090XV36C 826862014ACX-024-230 TXV 24000 16 13 CX35-30/36C SLP98UH090XV36C 826862114ACX-024-230 TXV 24000 16 13 CX35-30A EL180UH045E36A 826858914ACX-024-230 TXV 24000 16 13 CX35-30A EL180UH045XE36A 826859014ACX-024-230 TXV 24000 16 13 CX35-30A SL280UH070V36A 826858714ACX-024-230 TXV 24000 16 13 CX35-30A SL280UH070XV36A 826858814ACX-024-230 TXV 24000 14.5 12.2 CX35-30A 826858614ACX-024-230 TXV 24000 16 13 CX35-30B EL180UH070E36B 826860114ACX-024-230 TXV 24000 16 13 CX35-30B EL180UH070XE36B 826860214ACX-024-230 TXV 24000 16 13 CX35-30B EL195UH030XE24B 860890014ACX-024-230 TXV 24000 16 13 CX35-30B EL195UH045XE24B 860890114ACX-024-230 TXV 24000 16 13 CX35-30B EL195UH045XE36B 826860314ACX-024-230 TXV 24000 16 13 CX35-30B EL195UH070XE36B 826859214ACX-024-230 TXV 24000 16 13 CX35-30B EL296UH045XE36B 826859314ACX-024-230 TXV 24000 16 13 CX35-30B EL296UH045XV36B 826859514ACX-024-230 TXV 24000 16 13 CX35-30B EL296UH070XE36B 826859414ACX-024-230 TXV 24000 16 13 CX35-30B EL296UH070XV36B 826859614ACX-024-230 TXV 24000 16 13 CX35-30B SL280UH090V36B 826859814ACX-024-230 TXV 24000 16 13 CX35-30B SL280UH090V48B 826859914ACX-024-230 TXV 24000 16 13 CX35-30B SL280UH090XV48B 826860014ACX-024-230 TXV 24000 16 13 CX35-30B SLP98UH070XV36B 826859714ACX-024-230 TXV 24000 14.5 12.2 CX35-30B 826859114ACX-024-230 TXV 24000 16 13 CX35-36A EL180UH045E36A 826862514ACX-024-230 TXV 24000 16 13 CX35-36A EL180UH045XE36A 826862614ACX-024-230 TXV 24000 16 13.5 CX35-36A SL280UH070V36A 8268623NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 94

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-024-230 TXV 24000 16 13.5 CX35-36A SL280UH070XV36A 826862414ACX-024-230 TXV 24000 14.5 12.5 CX35-36A 826862214ACX-024-230 TXV 24000 16 13.5 CX35-36B EL180UH070E36B 826863314ACX-024-230 TXV 24000 16 13.5 CX35-36B EL180UH070XE36B 826863414ACX-024-230 TXV 24000 16 13 CX35-36B EL195UH030XE24B 860890214ACX-024-230 TXV 24000 16 13 CX35-36B EL195UH045XE24B 860890314ACX-024-230 TXV 24000 16 13 CX35-36B EL195UH045XE36B 826863514ACX-024-230 TXV 24000 16 13 CX35-36B EL195UH070XE36B 826863614ACX-024-230 TXV 24000 16 13 CX35-36B EL296UH045XE36B 826863714ACX-024-230 TXV 24000 16 13 CX35-36B EL296UH045XV36B 826862914ACX-024-230 TXV 24000 16 13 CX35-36B EL296UH070XE36B 826862814ACX-024-230 TXV 24000 16 13 CX35-36B EL296UH070XV36B 826863014ACX-024-230 TXV 24000 16 13.5 CX35-36B SL280UH090V36B 826863814ACX-024-230 TXV 24000 16 13 CX35-36B SL280UH090V48B 826863914ACX-024-230 TXV 24000 16 13 CX35-36B SL280UH090XV48B 826863214ACX-024-230 TXV 24000 16 13 CX35-36B SLP98UH070XV36B 826863114ACX-024-230 TXV 24000 14.5 12.5 CX35-36B 826862714ACX-024-230 TXV 23800 14.25 12.2 CX38-25B 1054615914ACX-030-230 RFC 28000 14 12.2 C35-30A 847100914ACX-030-230 RFC 28000 14 12.2 C35-30B 847101114ACX-030-230 RFC 28000 14 12.2 C35-36A 847101314ACX-030-230 RFC 28000 14 12.2 C35-36B 847101514ACX-030-230 RFC 27400 14 12.2 C35-48B 847101614ACX-030-230 RFC 27400 14 12.2 C35-48C 847101714ACX-030-230 RFC 28000 14.25 12.2 CH33-31A 750997114ACX-030-230 RFC 28000 14.25 12.2 CH33-31B 750997714ACX-030-230 RFC 28000 14 12.2 CH33-42B 751001514ACX-030-230 RFC 28000 14.5 12.5 CH33-43B 751001614ACX-030-230 RFC 28000 14 12.2 CH35-30A 1051672714ACX-030-230 RFC 28000 14 12.2 CH35-30B 1051672814ACX-030-230 RFC 28000 14 12.2 CH35-42B 1051454814ACX-030-230 RFC 27400 14 12.2 CH35-48B 1051454914ACX-030-230 RFC 27400 14 12.2 CH35-48C 1051455014ACX-030-230 TXV 28000 15.1 12.5 C35-24A EL180UH045E36A 826831414ACX-030-230 TXV 28000 15.1 12.5 C35-24A EL180UH045XE36A 826831514ACX-030-230 TXV 28000 15.5 12.5 C35-24A SL280UH070V36A 826831214ACX-030-230 TXV 28000 15.5 12.5 C35-24A SL280UH070XV36A 826831314ACX-030-230 TXV 28000 15.5 12.5 C35-24B EL180UH070E36B 826831814ACX-030-230 TXV 28000 15.5 12.5 C35-24B EL180UH070XE36B 826831914ACX-030-230 TXV 27800 15.5 12.5 C35-24B EL180UH090E48B 826831614ACX-030-230 TXV 27800 15.5 12.5 C35-24B EL180UH090XE48B 826831714ACX-030-230 TXV 28000 15.1 12.5 C35-24B EL195UH045XE36B 826832014ACX-030-230 TXV 28000 15 12.5 C35-24B EL195UH070XE36B 826832214ACX-030-230 TXV 28000 15.1 12.5 C35-24B EL296UH045XE36B 826832114ACX-030-230 TXV 28000 15 12.5 C35-24B EL296UH070XE36B 826832614ACX-030-230 TXV 28000 15.1 12.5 C35-24B EL296UH070XV36B 826832314ACX-030-230 TXV 28000 15.5 12.5 C35-24B SL280UH090V36B 826832514ACX-030-230 TXV 28000 15.1 12.5 C35-24B SLP98UH070XV36B 826832414ACX-030-230 TXV 28000 15.1 12.5 C35-30/36A EL180UH045E36A 8268346NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 95

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-030-230 TXV 28000 15.1 12.5 C35-30/36A EL180UH045XE36A 826834714ACX-030-230 TXV 28000 15.5 12.5 C35-30/36A SL280UH070V36A 826834414ACX-030-230 TXV 28000 15.5 12.5 C35-30/36A SL280UH070XV36A 826834514ACX-030-230 TXV 28000 15.5 12.5 C35-30/36B EL180UH070E36B 826835014ACX-030-230 TXV 28000 15.5 12.5 C35-30/36B EL180UH070XE36B 826835114ACX-030-230 TXV 28000 15.5 12.5 C35-30/36B EL180UH090E48B 826835214ACX-030-230 TXV 28000 15.5 12.5 C35-30/36B EL180UH090XE48B 826835814ACX-030-230 TXV 28000 15.1 12.5 C35-30/36B EL195UH045XE36B 826835314ACX-030-230 TXV 28000 15.1 12.5 C35-30/36B EL195UH070XE36B 826835514ACX-030-230 TXV 28000 15.1 12.5 C35-30/36B EL296UH045XE36B 826835414ACX-030-230 TXV 27800 15.1 12.5 C35-30/36B EL296UH045XV36B 826835914ACX-030-230 TXV 28000 15.1 12.5 C35-30/36B EL296UH070XE36B 826835614ACX-030-230 TXV 28000 15.5 12.5 C35-30/36B EL296UH070XV36B 826834814ACX-030-230 TXV 28000 15.5 12.5 C35-30/36B SL280UH090V36B 826834914ACX-030-230 TXV 28000 15.5 12.5 C35-30/36B SLP98UH070XV36B 826835714ACX-030-230 TXV 28000 15.1 12.5 C35-30/36C EL195UH090XE48C 826836314ACX-030-230 TXV 28000 15.1 12.5 C35-30/36C EL296UH090XE48C 826836014ACX-030-230 TXV 28000 15.5 12.5 C35-30/36C EL296UH090XV36C 826836114ACX-030-230 TXV 28000 15.5 12.5 C35-30/36C SLP98UH090XV36C 826836214ACX-030-230 TXV 28000 15.5 12.5 C35-30A EL180UH045E36A 826832914ACX-030-230 TXV 28000 15.5 12.5 C35-30A EL180UH045XE36A 826833014ACX-030-230 TXV 28000 16 13 C35-30A SL280UH070V36A 826833114ACX-030-230 TXV 28000 16 13 C35-30A SL280UH070XV36A 826832814ACX-030-230 TXV 28000 14.25 12.2 C35-30A 826832714ACX-030-230 TXV 28000 16 13 C35-30B EL180UH070E36B 826833414ACX-030-230 TXV 28000 16 13 C35-30B EL180UH070XE36B 826834214ACX-030-230 TXV 28000 16 13 C35-30B EL180UH090E48B 826833514ACX-030-230 TXV 28000 16 13 C35-30B EL180UH090XE48B 826833614ACX-030-230 TXV 28000 15.5 12.5 C35-30B EL195UH045XE36B 826833714ACX-030-230 TXV 28000 15.1 12.5 C35-30B EL195UH070XE36B 826833914ACX-030-230 TXV 28000 15.5 12.5 C35-30B EL296UH045XE36B 826833814ACX-030-230 TXV 28000 15.1 12.5 C35-30B EL296UH070XE36B 826834314ACX-030-230 TXV 28000 16 13 C35-30B EL296UH070XV36B 826834014ACX-030-230 TXV 28000 16 13 C35-30B SL280UH090V36B 826833314ACX-030-230 TXV 28000 16 13 C35-30B SLP98UH070XV36B 826834114ACX-030-230 TXV 28000 14.25 12.2 C35-30B 826833214ACX-030-230 TXV 28000 16 13 C35-36A EL180UH045E36A 826836814ACX-030-230 TXV 28000 16 13 C35-36A EL180UH045XE36A 826836714ACX-030-230 TXV 28000 16 13 C35-36A SL280UH070V36A 826836514ACX-030-230 TXV 28000 16 13 C35-36A SL280UH070XV36A 826836614ACX-030-230 TXV 28000 14.5 12.2 C35-36A 826836414ACX-030-230 TXV 28000 16 13 C35-36B EL180UH070E36B 826837114ACX-030-230 TXV 28000 16 13 C35-36B EL180UH070XE36B 826837214ACX-030-230 TXV 28000 16 13 C35-36B EL180UH090E48B 826837314ACX-030-230 TXV 28000 16 13 C35-36B EL180UH090XE48B 826838014ACX-030-230 TXV 28000 15.5 12.5 C35-36B EL195UH045XE36B 826837414ACX-030-230 TXV 28000 15.5 12.5 C35-36B EL195UH070XE36B 826837614ACX-030-230 TXV 28000 15.5 12.5 C35-36B EL296UH045XE36B 826837514ACX-030-230 TXV 28000 15.5 12.5 C35-36B EL296UH045XV36B 8268378NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 96

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-030-230 TXV 28000 15.5 12.5 C35-36B EL296UH070XE36B 826837714ACX-030-230 TXV 28000 16 13 C35-36B EL296UH070XV36B 826838114ACX-030-230 TXV 28000 16 13 C35-36B SL280UH090V36B 826837014ACX-030-230 TXV 28000 16 13 C35-36B SLP98UH070XV36B 826837914ACX-030-230 TXV 28000 14.5 12.2 C35-36B 826836914ACX-030-230 TXV 28000 16 13 C35-48B EL180UH070E36B 826838414ACX-030-230 TXV 28000 16 13 C35-48B EL180UH070XE36B 826838514ACX-030-230 TXV 28000 16 13 C35-48B EL180UH090E48B 826838614ACX-030-230 TXV 28000 16 13 C35-48B EL180UH090XE48B 826839314ACX-030-230 TXV 28000 15.5 12.5 C35-48B EL195UH045XE36B 826838714ACX-030-230 TXV 28000 15.5 12.5 C35-48B EL195UH070XE36B 826838914ACX-030-230 TXV 28000 15.5 12.5 C35-48B EL296UH045XE36B 826838814ACX-030-230 TXV 28000 15.5 12.5 C35-48B EL296UH045XV36B 826839114ACX-030-230 TXV 28000 15.5 12.5 C35-48B EL296UH070XE36B 826839014ACX-030-230 TXV 28000 16 13 C35-48B EL296UH070XV36B 826839414ACX-030-230 TXV 28000 16 13 C35-48B SL280UH090V36B 826838314ACX-030-230 TXV 28000 16 13 C35-48B SLP98UH070XV36B 826839214ACX-030-230 TXV 28000 14.5 12.2 C35-48B 826838214ACX-030-230 TXV 28000 16 13 C35-48C EL195UH090XE48C 826839614ACX-030-230 TXV 28000 16 13 C35-48C EL296UH090XE48C 826839714ACX-030-230 TXV 28000 16 13 C35-48C EL296UH090XV36C 826839814ACX-030-230 TXV 28000 16 13 C35-48C EL296UH090XV48C 826840014ACX-030-230 TXV 28000 16 13 C35-48C SLP98UH090XV36C 826839914ACX-030-230 TXV 28000 16 13 C35-48C SLP98UH090XV48C 826840114ACX-030-230 TXV 28000 14.5 12.2 C35-48C 826839514ACX-030-230 TXV 28600 16 13 CBA27UHE-030 1025937614ACX-030-230 TXV 28600 16 13 CBA27UHE-036 1025937714ACX-030-230 TXV 28000 14.5 12.2 CBX25UH-036 750992014ACX-030-230 TXV 28000 15.1 12.5 CBX25UHV-030 750992114ACX-030-230 TXV 28000 15.1 12.5 CBX25UHV-036 750992214ACX-030-230 TXV 28000 16 13 CBX27UH-030 750992314ACX-030-230 TXV 28000 16 13 CBX27UH-036 750992414ACX-030-230 TXV 28000 15 12.5 CBX32M-030 750992514ACX-030-230 TXV 28000 15 12.5 CBX32M-036 750992614ACX-030-230 TXV 28000 14.5 12.5 CBX32MV-024/030 750992714ACX-030-230 TXV 28000 15.1 12.5 CBX32MV-036 750992814ACX-030-230 TXV 28000 15.1 12.5 CBX40UHV-030 750992914ACX-030-230 TXV 28000 15.5 12.5 CBX40UHV-036 751308914ACX-030-230 TXV 26800 15 12.5 CH23-31 EL180UH070E36B 751309014ACX-030-230 TXV 26800 15 12.5 CH23-31 EL180UH070XE36B 751309114ACX-030-230 TXV 26600 14.25 12.2 CH23-31 EL195UH045XE36B 751328114ACX-030-230 TXV 26600 14.25 12.2 CH23-31 EL195UH070XE36B 751328514ACX-030-230 TXV 26600 14.25 12.2 CH23-31 EL296UH045XE36B 751328214ACX-030-230 TXV 26600 14.5 12.2 CH23-31 EL296UH045XV36B 750993014ACX-030-230 TXV 26600 14.25 12.2 CH23-31 EL296UH070XE36B 751328614ACX-030-230 TXV 26800 14.5 12.5 CH23-31 EL296UH070XV36B 750993214ACX-030-230 TXV 26800 15.1 12.5 CH23-31 SL280UH090V36B 750993114ACX-030-230 TXV 26800 14.5 12.5 CH23-31 SLP98UH070XV36B 750993314ACX-030-230 TXV 28000 15.5 12.5 CH23-41 EL180UH045E36A 7509936NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 97

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-030-230 TXV 28000 15.5 12.5 CH23-41 EL180UH045XE36A 750993714ACX-030-230 TXV 28000 15.5 12.5 CH23-41 EL180UH070E36B 750993814ACX-030-230 TXV 28000 15.5 12.5 CH23-41 EL180UH070XE36B 750993914ACX-030-230 TXV 28000 16 13 CH23-41 EL180UH090E48B 750994014ACX-030-230 TXV 28000 16 13 CH23-41 EL180UH090XE48B 750994114ACX-030-230 TXV 28000 15.1 12.5 CH23-41 EL195UH045XE36B 750994214ACX-030-230 TXV 28000 15.1 12.5 CH23-41 EL195UH070XE36B 750994414ACX-030-230 TXV 28000 15.1 12.5 CH23-41 EL296UH045XE36B 750994314ACX-030-230 TXV 28000 15.1 12.5 CH23-41 EL296UH045XV36B 750994614ACX-030-230 TXV 28000 15.1 12.5 CH23-41 EL296UH070XE36B 750994514ACX-030-230 TXV 28000 15.5 12.5 CH23-41 EL296UH070XV36B 750994714ACX-030-230 TXV 28000 16 13 CH23-41 SL280UH090V36B 750993514ACX-030-230 TXV 28000 15.5 12.5 CH23-41 SLP98UH070XV36B 750994814ACX-030-230 TXV 27400 15 12.5 CH33-19 EL180UH045E36A 750994914ACX-030-230 TXV 27400 15 12.5 CH33-19 EL180UH045XE36A 750995014ACX-030-230 TXV 27600 15.1 12.5 CH33-19 SL280UH070V36A 750995114ACX-030-230 TXV 27600 15.1 12.5 CH33-19 SL280UH070XV36A 750995214ACX-030-230 TXV 27400 15 12.5 CH33-24/30 EL180UH045E36A 751309414ACX-030-230 TXV 27400 15 12.5 CH33-24/30 EL180UH045XE36A 751309514ACX-030-230 TXV 27400 15 12.5 CH33-24/30 SL280UH070V36A 751309214ACX-030-230 TXV 27400 15 12.5 CH33-24/30 SL280UH070XV36A 751309314ACX-030-230 TXV 28000 15.1 12.5 CH33-25A EL180UH045E36A 750995714ACX-030-230 TXV 28000 15.1 12.5 CH33-25A EL180UH045XE36A 750995814ACX-030-230 TXV 28000 15.5 12.5 CH33-25A SL280UH070V36A 750995514ACX-030-230 TXV 28000 15.5 12.5 CH33-25A SL280UH070XV36A 750995614ACX-030-230 TXV 28000 15.5 12.5 CH33-25B EL180UH070E36B 750996114ACX-030-230 TXV 28000 15.5 12.5 CH33-25B EL180UH070XE36B 750996214ACX-030-230 TXV 28000 15.5 12.5 CH33-25B EL180UH090E48B 750996314ACX-030-230 TXV 28000 15.5 12.5 CH33-25B EL180UH090XE48B 750996414ACX-030-230 TXV 28000 15.1 12.5 CH33-25B EL195UH045XE36B 750996514ACX-030-230 TXV 28000 15.1 12.5 CH33-25B EL195UH070XE36B 750996714ACX-030-230 TXV 28000 15.1 12.5 CH33-25B EL296UH045XE36B 751309614ACX-030-230 TXV 28000 15.1 12.5 CH33-25B EL296UH045XV36B 750996614ACX-030-230 TXV 28000 15.1 12.5 CH33-25B EL296UH070XE36B 750996814ACX-030-230 TXV 28000 15.5 12.5 CH33-25B EL296UH070XV36B 750996914ACX-030-230 TXV 28000 16 13 CH33-25B SL280UH090V36B 915035814ACX-030-230 TXV 28000 15.5 12.5 CH33-25B SLP98UH070XV36B 750997014ACX-030-230 TXV 28000 15.5 12.5 CH33-31A EL180UH045E36A 750997514ACX-030-230 TXV 28000 15.5 12.5 CH33-31A EL180UH045XE36A 750997614ACX-030-230 TXV 28000 15.5 12.5 CH33-31A SL280UH070V36A 750997314ACX-030-230 TXV 28000 15.5 12.5 CH33-31A SL280UH070XV36A 750997414ACX-030-230 TXV 28000 14.25 12.2 CH33-31A 750997214ACX-030-230 TXV 28000 16 13 CH33-31B EL180UH070E36B 750998014ACX-030-230 TXV 28000 16 13 CH33-31B EL180UH070XE36B 750998114ACX-030-230 TXV 28000 16 13 CH33-31B EL180UH090E48B 750998214ACX-030-230 TXV 28000 16 13 CH33-31B EL180UH090XE48B 750998314ACX-030-230 TXV 28000 15.5 12.5 CH33-31B EL195UH045XE36B 750998414ACX-030-230 TXV 28000 15.5 12.5 CH33-31B EL195UH070XE36B 750998614ACX-030-230 TXV 28000 15.5 12.5 CH33-31B EL296UH045XE36B 7509985NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 98

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-030-230 TXV 28000 15.5 12.5 CH33-31B EL296UH045XV36B 750998814ACX-030-230 TXV 28000 15.5 12.5 CH33-31B EL296UH070XE36B 750998714ACX-030-230 TXV 28000 16 13 CH33-31B EL296UH070XV36B 750998914ACX-030-230 TXV 28000 16 13 CH33-31B SL280UH090V36B 750997914ACX-030-230 TXV 28000 16 13 CH33-31B SLP98UH070XV36B 750999014ACX-030-230 TXV 28000 14.5 12.2 CH33-31B 750997814ACX-030-230 TXV 27800 15.1 12.5 CH33-36A EL180UH045E36A 750999214ACX-030-230 TXV 27800 15.1 12.5 CH33-36A EL180UH045XE36A 750999314ACX-030-230 TXV 28000 15.1 12.5 CH33-36A SL280UH070V36A 750999414ACX-030-230 TXV 28000 15.1 12.5 CH33-36A SL280UH070XV36A 750999514ACX-030-230 TXV 28000 15.5 12.5 CH33-36B EL180UH070E36B 750999914ACX-030-230 TXV 28000 15.5 12.5 CH33-36B EL180UH070XE36B 751000014ACX-030-230 TXV 28000 15.5 12.5 CH33-36B EL180UH090E48B 751000114ACX-030-230 TXV 28000 15.5 12.5 CH33-36B EL180UH090XE48B 751000214ACX-030-230 TXV 28000 15.1 12.5 CH33-36B EL195UH045XE36B 751000314ACX-030-230 TXV 28000 15.1 12.5 CH33-36B EL195UH070XE36B 751000514ACX-030-230 TXV 28000 15.1 12.5 CH33-36B EL296UH045XE36B 751000414ACX-030-230 TXV 27800 15.1 12.5 CH33-36B EL296UH045XV36B 750999714ACX-030-230 TXV 28000 15.1 12.5 CH33-36B EL296UH070XE36B 751000614ACX-030-230 TXV 28000 15.5 12.5 CH33-36B SL280UH090V36B 750999814ACX-030-230 TXV 28000 15.5 12.5 CH33-36B SLP98UH070XV36B 751000814ACX-030-230 TXV 28000 15.1 12.5 CH33-36C EL195UH090XE48C 751001114ACX-030-230 TXV 28000 15.1 12.5 CH33-36C EL296UH090XE48C 751001214ACX-030-230 TXV 28000 15.5 12.5 CH33-36C EL296UH090XV36C 761467014ACX-030-230 TXV 28000 15.5 12.5 CH33-36C SLP98UH090XV36C 751001414ACX-030-230 TXV 28000 16 13 CH33-42 EL180UH070E36B 751309914ACX-030-230 TXV 28000 16 13 CH33-42 EL180UH070XE36B 751310014ACX-030-230 TXV 28000 16 13 CH33-42 EL180UH090E48B 751310114ACX-030-230 TXV 28000 16 13 CH33-42 EL180UH090XE48B 751310214ACX-030-230 TXV 28000 15.5 12.5 CH33-42 EL195UH045XE36B 751310314ACX-030-230 TXV 28000 15.5 12.5 CH33-42 EL195UH070XE36B 751310514ACX-030-230 TXV 28000 15.5 12.5 CH33-42 EL296UH045XE36B 751310414ACX-030-230 TXV 28000 15.5 12.5 CH33-42 EL296UH045XV36B 751310714ACX-030-230 TXV 28000 15.5 12.5 CH33-42 EL296UH070XE36B 751310614ACX-030-230 TXV 28000 15.5 12.5 CH33-42 EL296UH070XV36B 751310814ACX-030-230 TXV 28000 15.5 12.5 CH33-42 SLP98UH070XV36B 751310914ACX-030-230 TXV 28000 14.25 12.2 CH33-42 751309714ACX-030-230 TXV 28000 16 13 CH33-43B EL180UH070E36B 751001914ACX-030-230 TXV 28000 16 13 CH33-43B EL180UH070XE36B 751002014ACX-030-230 TXV 28000 16 13 CH33-43B EL180UH090E48B 751002114ACX-030-230 TXV 28000 16 13 CH33-43B EL180UH090XE48B 751002214ACX-030-230 TXV 28000 16 13 CH33-43B EL195UH045XE36B 751002314ACX-030-230 TXV 28000 16 13 CH33-43B EL195UH070XE36B 751002514ACX-030-230 TXV 28000 16 13 CH33-43B EL296UH045XE36B 751002414ACX-030-230 TXV 28000 16 13 CH33-43B EL296UH045XV36B 751002714ACX-030-230 TXV 28000 16 13 CH33-43B EL296UH070XE36B 751002614ACX-030-230 TXV 28000 16 13 CH33-43B EL296UH070XV36B 751002814ACX-030-230 TXV 28000 16 13 CH33-43B SL280UH090V36B 751001814ACX-030-230 TXV 28000 16 13 CH33-43B SLP98UH070XV36B 7510029NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 99

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-030-230 TXV 28000 14.5 12.5 CH33-43B 751001714ACX-030-230 TXV 28000 16 13 CH33-43C EL195UH090XE48C 751003114ACX-030-230 TXV 28000 16 13 CH33-43C EL296UH090XE48C 751003214ACX-030-230 TXV 28000 16 13 CH33-43C EL296UH090XV36C 751003314ACX-030-230 TXV 28000 16 13 CH33-43C SLP98UH090XV36C 751003414ACX-030-230 TXV 28000 14.5 12.2 CH33-43C 751003014ACX-030-230 TXV 28000 15.5 12.5 CH35-24B EL180UH070E36B 751006114ACX-030-230 TXV 28000 15.5 12.5 CH35-30A EL180UH045E36A 751003814ACX-030-230 TXV 28000 15.5 12.5 CH35-30A EL180UH045XE36A 751003914ACX-030-230 TXV 28000 15.5 12.5 CH35-30A SL280UH070V36A 751003614ACX-030-230 TXV 28000 15.5 12.5 CH35-30A SL280UH070XV36A 751003714ACX-030-230 TXV 28000 14.25 12.2 CH35-30A 756565314ACX-030-230 TXV 28000 16 13 CH35-30B EL180UH070E36B 751004314ACX-030-230 TXV 28000 16 13 CH35-30B EL180UH070XE36B 751004414ACX-030-230 TXV 28000 16 13 CH35-30B EL180UH090E48B 751004514ACX-030-230 TXV 28000 16 13 CH35-30B EL180UH090XE48B 751004614ACX-030-230 TXV 28000 15.5 12.5 CH35-30B EL195UH045XE36B 751004714ACX-030-230 TXV 28000 15.5 12.5 CH35-30B EL195UH070XE36B 751004914ACX-030-230 TXV 28000 15.5 12.5 CH35-30B EL296UH045XE36B 751005114ACX-030-230 TXV 28000 15.5 12.5 CH35-30B EL296UH045XV36B 751004814ACX-030-230 TXV 28000 15.5 12.5 CH35-30B EL296UH070XE36B 751005014ACX-030-230 TXV 28000 16 13 CH35-30B EL296UH070XV36B 751005214ACX-030-230 TXV 28000 16 13 CH35-30B SL280UH090V36B 762267014ACX-030-230 TXV 28000 16 13 CH35-30B SLP98UH070XV36B 751005314ACX-030-230 TXV 28000 14.5 12.2 CH35-30B 751004114ACX-030-230 TXV 28000 15.1 12.5 CH35-36A EL180UH045E36A 751005714ACX-030-230 TXV 28000 15.1 12.5 CH35-36A EL180UH045XE36A 751005814ACX-030-230 TXV 28000 15.1 12.5 CH35-36A SL280UH070V36A 751005514ACX-030-230 TXV 28000 15.1 12.5 CH35-36A SL280UH070XV36A 751005614ACX-030-230 TXV 28000 15.5 12.5 CH35-36B EL180UH070E36B 751006214ACX-030-230 TXV 28000 15.5 12.5 CH35-36B EL180UH070XE36B 761464714ACX-030-230 TXV 28000 15.5 12.5 CH35-36B EL180UH090E48B 751006014ACX-030-230 TXV 28000 15.5 12.5 CH35-36B EL180UH090XE48B 761464814ACX-030-230 TXV 28000 15.1 12.5 CH35-36B EL195UH045XE36B 751006514ACX-030-230 TXV 28000 15.1 12.5 CH35-36B EL195UH070XE36B 751006714ACX-030-230 TXV 28000 15.1 12.5 CH35-36B EL296UH045XE36B 751006614ACX-030-230 TXV 28000 15.1 12.5 CH35-36B EL296UH045XV36B 751006914ACX-030-230 TXV 28000 15.1 12.5 CH35-36B EL296UH070XE36B 751006814ACX-030-230 TXV 28000 15.5 12.5 CH35-36B EL296UH070XV36B 751007014ACX-030-230 TXV 28000 15.5 12.5 CH35-36B SLP98UH070XV36B 751007114ACX-030-230 TXV 28000 15.1 12.5 CH35-36C EL195UH090XE48C 751007414ACX-030-230 TXV 28000 15.1 12.5 CH35-36C EL296UH090XE48C 751007514ACX-030-230 TXV 28000 16 13 CH35-36C EL296UH090XV36C 751007614ACX-030-230 TXV 28000 16 13 CH35-36C SLP98UH090XV36C 751007714ACX-030-230 TXV 28000 16 13 CH35-42B EL180UH070E36B 751008014ACX-030-230 TXV 28000 16 13 CH35-42B EL180UH070XE36B 751008114ACX-030-230 TXV 28000 16 13 CH35-42B EL180UH090E48B 751008214ACX-030-230 TXV 28000 16 13 CH35-42B EL180UH090XE48B 751008314ACX-030-230 TXV 28000 16 13 CH35-42B EL195UH045XE36B 7510084NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 100

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-030-230 TXV 28000 16 13 CH35-42B EL195UH070XE36B 751008714ACX-030-230 TXV 28000 16 13 CH35-42B EL296UH045XE36B 751008814ACX-030-230 TXV 28000 16 13 CH35-42B EL296UH045XV36B 751008514ACX-030-230 TXV 28000 16 13 CH35-42B EL296UH070XE36B 751008614ACX-030-230 TXV 28000 16 13 CH35-42B EL296UH070XV36B 751008914ACX-030-230 TXV 28000 16 13 CH35-42B SL280UH090V36B 751007914ACX-030-230 TXV 28000 16 13 CH35-42B SLP98UH070XV36B 751009014ACX-030-230 TXV 28000 14.5 12.5 CH35-42B 751007814ACX-030-230 TXV 28000 15.5 12.5 CH35-42C EL195UH090XE48C 751009214ACX-030-230 TXV 28000 15.5 12.5 CH35-42C EL296UH090XE48C 751009314ACX-030-230 TXV 28000 16 13 CH35-42C EL296UH090XV36C 751009414ACX-030-230 TXV 28000 16 13 CH35-42C SLP98UH090XV36C 751009514ACX-030-230 TXV 28000 14.5 12.2 CH35-42C 751009114ACX-030-230 TXV 26800 14.5 12.2 CR33-24A EL180DF045E36A 751009614ACX-030-230 TXV 26800 14.25 12.2 CR33-24B EL180DF070E36B 751010014ACX-030-230 TXV 26600 14.25 12.2 CR33-24B EL296DF045XV36B 751311114ACX-030-230 TXV 26600 14.25 12.2 CR33-24B SL280DF090V48B 751009714ACX-030-230 TXV 26600 14.25 12.2 CR33-24B SLP98DF070XV36B 751311014ACX-030-230 TXV 28000 15.1 12.5 CR33-30/36A EL180DF045E36A 751010414ACX-030-230 TXV 28000 15.5 12.5 CR33-30/36A SL280DF070V36A 751010314ACX-030-230 TXV 28000 15.5 12.5 CR33-30/36B EL180DF070E36B 751010814ACX-030-230 TXV 28000 15.5 12.5 CR33-30/36B EL180DF090E48B 751010914ACX-030-230 TXV 28000 15.1 12.5 CR33-30/36B EL195DF045XE36B 751011014ACX-030-230 TXV 28000 15.5 12.5 CR33-30/36B EL195DF070XE48B 751011214ACX-030-230 TXV 28000 15.1 12.5 CR33-30/36B EL296DF045XE36B 751011114ACX-030-230 TXV 28000 15.5 12.5 CR33-30/36B EL296DF045XV36B 751011414ACX-030-230 TXV 28000 15.5 12.5 CR33-30/36B EL296DF070XE48B 751011314ACX-030-230 TXV 28000 15.1 12.5 CR33-30/36B EL296DF070XV48B 761466114ACX-030-230 TXV 28000 15.5 12.5 CR33-30/36B SL280DF090V48B 762267214ACX-030-230 TXV 28000 15.5 12.5 CR33-30/36B SLP98DF070XV36B 751011614ACX-030-230 TXV 28000 16 13 CR33-30/36C SLP98DF090XV36C 751011914ACX-030-230 TXV 28000 15.1 12.5 CX35-24A EL180UH045E36A 826840414ACX-030-230 TXV 28000 15.1 12.5 CX35-24A EL180UH045XE36A 826840514ACX-030-230 TXV 28000 15.5 12.5 CX35-24A SL280UH070V36A 826840214ACX-030-230 TXV 28000 15.5 12.5 CX35-24A SL280UH070XV36A 826840314ACX-030-230 TXV 28000 15.5 12.5 CX35-24B EL180UH070E36B 826841114ACX-030-230 TXV 28000 15.5 12.5 CX35-24B EL180UH070XE36B 826840614ACX-030-230 TXV 27800 15.5 12.5 CX35-24B EL180UH090E48B 826840814ACX-030-230 TXV 27800 15.5 12.5 CX35-24B EL180UH090XE48B 826840914ACX-030-230 TXV 28000 15.1 12.5 CX35-24B EL195UH045XE36B 826841214ACX-030-230 TXV 28000 15 12.5 CX35-24B EL195UH070XE36B 826841414ACX-030-230 TXV 28000 15.1 12.5 CX35-24B EL296UH045XE36B 826841314ACX-030-230 TXV 28000 15.1 12.5 CX35-24B EL296UH045XV36B 826841614ACX-030-230 TXV 28000 15 12.5 CX35-24B EL296UH070XE36B 826841514ACX-030-230 TXV 28000 15.1 12.5 CX35-24B EL296UH070XV36B 826840714ACX-030-230 TXV 28000 15.5 12.5 CX35-24B SL280UH090V36B 826841014ACX-030-230 TXV 28000 15.1 12.5 CX35-24B SLP98UH070XV36B 826841714ACX-030-230 TXV 28000 15.1 12.5 CX35-30/36A EL180UH045E36A 826843614ACX-030-230 TXV 28000 15.1 12.5 CX35-30/36A EL180UH045XE36A 8268439NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 101

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-030-230 TXV 28000 15.5 12.5 CX35-30/36A SL280UH070V36A 826843714ACX-030-230 TXV 28000 15.5 12.5 CX35-30/36A SL280UH070XV36A 826843814ACX-030-230 TXV 28000 15.5 12.5 CX35-30/36B EL180UH070E36B 826844614ACX-030-230 TXV 28000 15.5 12.5 CX35-30/36B EL180UH070XE36B 826844014ACX-030-230 TXV 28000 15.5 12.5 CX35-30/36B EL180UH090E48B 826844114ACX-030-230 TXV 28000 15.5 12.5 CX35-30/36B EL180UH090XE48B 826844714ACX-030-230 TXV 28000 15.1 12.5 CX35-30/36B EL195UH045XE36B 826844814ACX-030-230 TXV 28000 15.1 12.5 CX35-30/36B EL195UH070XE36B 826845014ACX-030-230 TXV 28000 15.1 12.5 CX35-30/36B EL296UH045XE36B 826844914ACX-030-230 TXV 27800 15.1 12.5 CX35-30/36B EL296UH045XV36B 826844414ACX-030-230 TXV 28000 15.1 12.5 CX35-30/36B EL296UH070XE36B 826844214ACX-030-230 TXV 28000 15.5 12.5 CX35-30/36B EL296UH070XV36B 826844314ACX-030-230 TXV 28000 15.5 12.5 CX35-30/36B SL280UH090V36B 826844514ACX-030-230 TXV 28000 15.5 12.5 CX35-30/36B SLP98UH070XV36B 826845114ACX-030-230 TXV 28000 15.1 12.5 CX35-30/36C EL195UH090XE48C 826845314ACX-030-230 TXV 28000 15.1 12.5 CX35-30/36C EL296UH090XE48C 826845414ACX-030-230 TXV 28000 15.5 12.5 CX35-30/36C EL296UH090XV36C 826845514ACX-030-230 TXV 28000 15.5 12.5 CX35-30/36C SLP98UH090XV36C 826845214ACX-030-230 TXV 28000 15.5 12.5 CX35-30A EL180UH045E36A 826842114ACX-030-230 TXV 28000 15.5 12.5 CX35-30A EL180UH045XE36A 826842214ACX-030-230 TXV 28000 16 13 CX35-30A SL280UH070V36A 826841914ACX-030-230 TXV 28000 16 13 CX35-30A SL280UH070XV36A 826842014ACX-030-230 TXV 28000 14.25 12.2 CX35-30A 826841814ACX-030-230 TXV 28000 16 13 CX35-30B EL180UH070E36B 826842814ACX-030-230 TXV 28000 16 13 CX35-30B EL180UH070XE36B 826842514ACX-030-230 TXV 28000 16 13 CX35-30B EL180UH090E48B 826842914ACX-030-230 TXV 28000 16 13 CX35-30B EL180UH090XE48B 826843014ACX-030-230 TXV 28000 15.5 12.5 CX35-30B EL195UH045XE36B 826843114ACX-030-230 TXV 28000 15.1 12.5 CX35-30B EL195UH070XE36B 826843314ACX-030-230 TXV 28000 15.5 12.5 CX35-30B EL296UH045XE36B 826843214ACX-030-230 TXV 28000 15.5 12.5 CX35-30B EL296UH045XV36B 826843414ACX-030-230 TXV 28000 15.1 12.5 CX35-30B EL296UH070XE36B 826842614ACX-030-230 TXV 28000 16 13 CX35-30B EL296UH070XV36B 826843514ACX-030-230 TXV 28000 16 13 CX35-30B SL280UH090V36B 826842714ACX-030-230 TXV 28000 16 13 CX35-30B SLP98UH070XV36B 826842414ACX-030-230 TXV 28000 14.25 12.2 CX35-30B 826842314ACX-030-230 TXV 28000 16 13 CX35-36A EL180UH045E36A 826845914ACX-030-230 TXV 28000 16 13 CX35-36A EL180UH045XE36A 826846014ACX-030-230 TXV 28000 16 13 CX35-36A SL280UH070V36A 826845714ACX-030-230 TXV 28000 16 13 CX35-36A SL280UH070XV36A 826845814ACX-030-230 TXV 28000 14.5 12.2 CX35-36A 826845614ACX-030-230 TXV 28000 16 13 CX35-36B EL180UH070E36B 826846214ACX-030-230 TXV 28000 16 13 CX35-36B EL180UH070XE36B 826846314ACX-030-230 TXV 28000 16 13 CX35-36B EL180UH090E48B 826846714ACX-030-230 TXV 28000 16 13 CX35-36B EL180UH090XE48B 826846814ACX-030-230 TXV 28000 15.5 12.5 CX35-36B EL195UH045XE36B 826846914ACX-030-230 TXV 28000 15.5 12.5 CX35-36B EL195UH070XE36B 826846414ACX-030-230 TXV 28000 15.5 12.5 CX35-36B EL296UH045XE36B 826847014ACX-030-230 TXV 28000 15.5 12.5 CX35-36B EL296UH045XV36B 8268471NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 102

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-030-230 TXV 28000 15.5 12.5 CX35-36B EL296UH070XE36B 826846514ACX-030-230 TXV 28000 16 13 CX35-36B EL296UH070XV36B 826847214ACX-030-230 TXV 28000 16 13 CX35-36B SL280UH090V36B 826846614ACX-030-230 TXV 28000 16 13 CX35-36B SLP98UH070XV36B 826847314ACX-030-230 TXV 28000 14.5 12.2 CX35-36B 826846114ACX-030-230 TXV 28000 16 13 CX35-48B EL180UH070E36B 826847514ACX-030-230 TXV 28000 16 13 CX35-48B EL180UH070XE36B 826847614ACX-030-230 TXV 28000 16 13 CX35-48B EL180UH090E48B 826848014ACX-030-230 TXV 28000 16 13 CX35-48B EL180UH090XE48B 826848114ACX-030-230 TXV 28000 15.5 12.5 CX35-48B EL195UH045XE36B 826848214ACX-030-230 TXV 28000 15.5 12.5 CX35-48B EL195UH070XE36B 826847714ACX-030-230 TXV 28000 15.5 12.5 CX35-48B EL296UH045XE36B 826848314ACX-030-230 TXV 28000 15.5 12.5 CX35-48B EL296UH045XV36B 826848414ACX-030-230 TXV 28000 15.5 12.5 CX35-48B EL296UH070XE36B 826847814ACX-030-230 TXV 28000 16 13 CX35-48B EL296UH070XV36B 826848514ACX-030-230 TXV 28000 16 13 CX35-48B SL280UH090V36B 826847914ACX-030-230 TXV 28000 16 13 CX35-48B SLP98UH070XV36B 826848614ACX-030-230 TXV 28000 14.5 12.2 CX35-48B 826847414ACX-030-230 TXV 28000 16 13 CX35-48C EL195UH090XE48C 826849014ACX-030-230 TXV 28000 16 13 CX35-48C EL296UH090XE48C 826848814ACX-030-230 TXV 28000 16 13 CX35-48C EL296UH090XV36C 826848914ACX-030-230 TXV 28000 16 13 CX35-48C EL296UH090XV48C 826849214ACX-030-230 TXV 28000 16 13 CX35-48C SLP98UH090XV36C 826849114ACX-030-230 TXV 28000 16 13 CX35-48C SLP98UH090XV48C 826849314ACX-030-230 TXV 28000 14.5 12.2 CX35-48C 826848714ACX-030-230 TXV 28000 14.25 12.2 CX38-31B 1054629014ACX-036-230 RFC 34400 14 12.2 C35-49C 847101814ACX-036-230 RFC 34000 14 12.2 C35-50/60C 847102014ACX-036-230 RFC 33800 14 12.2 CH33-31B 751045614ACX-036-230 RFC 34600 14.5 12.2 CH33-43B 751050714ACX-036-230 RFC 34000 14.25 12.2 CH33-44/48B 751054114ACX-036-230 RFC 34000 14.25 12.2 CH33-48 751319214ACX-036-230 RFC 34600 14.5 12.2 CH33-49 751319314ACX-036-230 RFC 34400 14.25 12.2 CH33-50/60C 751059414ACX-036-230 RFC 34000 14 12.2 CH35-48C 1051455214ACX-036-230 RFC 34000 14 12.2 CH35-51C 1051455114ACX-036-230 TXV 33200 14.5 12.2 C35-30/36A EL180UH045E36A 826805414ACX-036-230 TXV 33200 14.5 12.2 C35-30/36A EL180UH045XE36A 826805514ACX-036-230 TXV 33400 15 12.2 C35-30/36A SL280UH070V36A 826805214ACX-036-230 TXV 33400 15 12.2 C35-30/36A SL280UH070XV36A 826805314ACX-036-230 TXV 33400 15.5 12.5 C35-30/36B EL180UH070E36B 826806114ACX-036-230 TXV 33400 15.5 12.5 C35-30/36B EL180UH070XE36B 826806214ACX-036-230 TXV 33400 15.1 12.5 C35-30/36B EL180UH090E48B 826806314ACX-036-230 TXV 33400 15.1 12.5 C35-30/36B EL180UH090XE48B 826806414ACX-036-230 TXV 33000 15 12.5 C35-30/36B EL195UH045XE36B 826806514ACX-036-230 TXV 33000 15 12.5 C35-30/36B EL296UH045XE36B 826805614ACX-036-230 TXV 33400 15 12.5 C35-30/36B EL296UH045XV36B 826805714ACX-036-230 TXV 33400 15 12.5 C35-30/36B EL296UH070XV36B 826805814ACX-036-230 TXV 33600 15.5 12.5 C35-30/36B SL280UH090V36B 8268066NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 103

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-036-230 TXV 33600 15.5 12.5 C35-30/36B SL280UH090V48B 826806714ACX-036-230 TXV 33600 15.5 12.5 C35-30/36B SL280UH090XV48B 826806014ACX-036-230 TXV 33400 15 12.5 C35-30/36B SLP98UH070XV36B 826805914ACX-036-230 TXV 33600 15.1 12.5 C35-30/36C EL180UH090E60C 826807514ACX-036-230 TXV 33400 15.5 12.5 C35-30/36C EL180UH110E60C 826807614ACX-036-230 TXV 33400 15.5 12.5 C35-30/36C EL180UH110XE60C 826807714ACX-036-230 TXV 33200 15.1 12.5 C35-30/36C EL195UH090XE48C 826807814ACX-036-230 TXV 33600 15.1 12.5 C35-30/36C EL195UH110XE60C 826808014ACX-036-230 TXV 33200 15.1 12.5 C35-30/36C EL296UH090XE48C 826807914ACX-036-230 TXV 33600 15.5 12.5 C35-30/36C EL296UH090XV36C 826807014ACX-036-230 TXV 33400 15.5 12.5 C35-30/36C EL296UH090XV48C 826807214ACX-036-230 TXV 33600 15.1 12.5 C35-30/36C EL296UH110XE60C 826806914ACX-036-230 TXV 33600 15.5 12.5 C35-30/36C EL296UH110XV48C 826807414ACX-036-230 TXV 33600 15.5 12.5 C35-30/36C SLP98UH090XV36C 826807114ACX-036-230 TXV 33400 15.5 12.5 C35-30/36C SLP98UH090XV48C 826807314ACX-036-230 TXV 33800 15.5 12.5 C35-30/36C SLP98UH110XV60C 826806814ACX-036-230 TXV 34200 15.1 12.5 C35-30A EL180UH045E36A 826803614ACX-036-230 TXV 34200 15.1 12.5 C35-30A EL180UH045XE36A 826803714ACX-036-230 TXV 34400 15.1 12.5 C35-30A SL280UH070V36A 826803414ACX-036-230 TXV 34400 15.1 12.5 C35-30A SL280UH070XV36A 826803514ACX-036-230 TXV 34400 15 12.5 C35-30B EL180UH070E36B 826804714ACX-036-230 TXV 34400 15 12.5 C35-30B EL180UH070XE36B 826804814ACX-036-230 TXV 34400 15.5 12.5 C35-30B EL180UH090E48B 826804914ACX-036-230 TXV 34400 15.5 12.5 C35-30B EL180UH090XE48B 826805014ACX-036-230 TXV 34000 14.5 12.2 C35-30B EL195UH045XE36B 826805114ACX-036-230 TXV 34000 15.1 12.5 C35-30B EL195UH070XE36B 826804114ACX-036-230 TXV 34000 14.5 12.2 C35-30B EL296UH045XE36B 826804014ACX-036-230 TXV 34200 15.1 12.5 C35-30B EL296UH045XV36B 826804314ACX-036-230 TXV 34000 15.1 12.5 C35-30B EL296UH070XE36B 826804214ACX-036-230 TXV 34200 15.1 12.5 C35-30B EL296UH070XV36B 826804414ACX-036-230 TXV 34400 15.5 12.5 C35-30B SL280UH090V36B 826803814ACX-036-230 TXV 34400 15.5 12.5 C35-30B SL280UH090V48B 826803914ACX-036-230 TXV 34400 15.5 12.5 C35-30B SL280UH090XV48B 826804614ACX-036-230 TXV 34200 15.1 12.5 C35-30B SLP98UH070XV36B 826804514ACX-036-230 TXV 34400 15.1 12.5 C35-36A EL180UH045E36A 826808414ACX-036-230 TXV 34400 15.1 12.5 C35-36A EL180UH045XE36A 826808514ACX-036-230 TXV 34600 15.5 12.5 C35-36A SL280UH070V36A 826808214ACX-036-230 TXV 34600 15.5 12.5 C35-36A SL280UH070XV36A 826808314ACX-036-230 TXV 34200 14.25 12.2 C35-36A 826808114ACX-036-230 TXV 34600 16 13 C35-36B EL180UH070E36B 826809414ACX-036-230 TXV 34600 16 13 C35-36B EL180UH070XE36B 826809514ACX-036-230 TXV 34600 16 13 C35-36B EL180UH090E48B 826809614ACX-036-230 TXV 34600 16 13 C35-36B EL180UH090XE48B 826809714ACX-036-230 TXV 34400 15 12.5 C35-36B EL195UH045XE36B 826809814ACX-036-230 TXV 34400 15 12.5 C35-36B EL195UH070XE36B 826808814ACX-036-230 TXV 34400 15 12.5 C35-36B EL296UH045XE36B 826808714ACX-036-230 TXV 34600 15.5 12.5 C35-36B EL296UH045XV36B 826809014ACX-036-230 TXV 34400 15 12.5 C35-36B EL296UH070XE36B 826808914ACX-036-230 TXV 34600 15.5 12.5 C35-36B EL296UH070XV36B 8268091NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 104

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-036-230 TXV 34800 16 13 C35-36B SL280UH090V36B 826809914ACX-036-230 TXV 34800 16 13 C35-36B SL280UH090V48B 826810014ACX-036-230 TXV 34800 16 13 C35-36B SL280UH090XV48B 826809314ACX-036-230 TXV 34600 15.5 12.5 C35-36B SLP98UH070XV36B 826809214ACX-036-230 TXV 34200 14.25 12.2 C35-36B 826808614ACX-036-230 TXV 34800 16 13 C35-48B EL180UH070E36B 826811314ACX-036-230 TXV 34800 16 13 C35-48B EL180UH070XE36B 826811414ACX-036-230 TXV 34800 16 13 C35-48B EL180UH090E48B 826811514ACX-036-230 TXV 34800 16 13 C35-48B EL180UH090XE48B 826810414ACX-036-230 TXV 34400 15 12.5 C35-48B EL195UH045XE36B 826810514ACX-036-230 TXV 34600 15.1 12.5 C35-48B EL195UH070XE36B 826810714ACX-036-230 TXV 34400 15 12.5 C35-48B EL296UH045XE36B 826810614ACX-036-230 TXV 34800 15.5 12.5 C35-48B EL296UH045XV36B 826810914ACX-036-230 TXV 34600 15.1 12.5 C35-48B EL296UH070XE36B 826810814ACX-036-230 TXV 34800 15.5 12.5 C35-48B EL296UH070XV36B 826810214ACX-036-230 TXV 34800 16 13 C35-48B SL280UH090V36B 826811014ACX-036-230 TXV 35000 16 13 C35-48B SL280UH090V48B 826811114ACX-036-230 TXV 35000 16 13 C35-48B SL280UH090XV48B 826811214ACX-036-230 TXV 34800 15.5 12.5 C35-48B SLP98UH070XV36B 826810314ACX-036-230 TXV 34400 14.5 12.2 C35-48B 826810114ACX-036-230 TXV 34800 16 13 C35-48C EL180UH090E60C 826812514ACX-036-230 TXV 34800 16 13 C35-48C EL180UH110E60C 826812614ACX-036-230 TXV 34800 16 13 C35-48C EL180UH110XE60C 826812714ACX-036-230 TXV 34600 15.5 12.5 C35-48C EL195UH090XE48C 826812814ACX-036-230 TXV 34800 16 13 C35-48C EL195UH110XE60C 826813014ACX-036-230 TXV 34600 15.5 12.5 C35-48C EL296UH090XE48C 826812914ACX-036-230 TXV 34800 16 13 C35-48C EL296UH090XV36C 826812014ACX-036-230 TXV 34800 16 13 C35-48C EL296UH090XV48C 826812214ACX-036-230 TXV 34600 16 13 C35-48C EL296UH110XE60C 826811914ACX-036-230 TXV 35000 16 13 C35-48C EL296UH110XV48C 826812414ACX-036-230 TXV 35200 16 13 C35-48C EL296UH110XV60C 826811714ACX-036-230 TXV 35400 16 13 C35-48C SL280UH090V60C 826813114ACX-036-230 TXV 35400 16 13 C35-48C SL280UH090XV60C 826813214ACX-036-230 TXV 35200 16 13 C35-48C SL280UH110V60C 826813314ACX-036-230 TXV 35200 16 13 C35-48C SL280UH110XV60C 826813414ACX-036-230 TXV 34800 16 13 C35-48C SLP98UH090XV36C 826812114ACX-036-230 TXV 34800 16 13 C35-48C SLP98UH090XV48C 826812314ACX-036-230 TXV 35200 16 13 C35-48C SLP98UH110XV60C 826811814ACX-036-230 TXV 34400 14.5 12.2 C35-48C 826811614ACX-036-230 TXV 35200 16 13 C35-49C EL180UH090E60C 826815014ACX-036-230 TXV 35000 16 13 C35-49C EL180UH110E60C 826815114ACX-036-230 TXV 35000 16 13 C35-49C EL180UH110XE60C 826815214ACX-036-230 TXV 34800 16 13 C35-49C EL195UH090XE48C 826814114ACX-036-230 TXV 35200 16 13 C35-49C EL195UH110XE60C 826814314ACX-036-230 TXV 34800 16 13 C35-49C EL296UH090XE48C 826814214ACX-036-230 TXV 35200 16 13 C35-49C EL296UH090XV36C 826814514ACX-036-230 TXV 35000 16 13 C35-49C EL296UH090XV48C 826813614ACX-036-230 TXV 35200 16 13 C35-49C EL296UH110XE60C 826814414ACX-036-230 TXV 35200 16 13 C35-49C EL296UH110XV48C 8268138NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 105

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-036-230 TXV 35600 16 13 C35-49C EL296UH110XV60C 826813914ACX-036-230 TXV 35600 16 13 C35-49C SL280UH090V60C 826815314ACX-036-230 TXV 35600 16 13 C35-49C SL280UH090XV60C 826814714ACX-036-230 TXV 35400 16 13 C35-49C SL280UH110V60C 826814814ACX-036-230 TXV 35400 16 13 C35-49C SL280UH110XV60C 826814914ACX-036-230 TXV 35200 16 13 C35-49C SLP98UH090XV36C 826814614ACX-036-230 TXV 35000 16 13 C35-49C SLP98UH090XV48C 826813714ACX-036-230 TXV 35600 16 13 C35-49C SLP98UH110XV60C 826814014ACX-036-230 TXV 34600 14.5 12.2 C35-49C 826813514ACX-036-230 TXV 34800 16 13 C35-50/60C EL180UH090E60C 826817114ACX-036-230 TXV 34800 16 13 C35-50/60C EL180UH110E60C 826817214ACX-036-230 TXV 34800 16 13 C35-50/60C EL180UH110XE60C 826816114ACX-036-230 TXV 34400 15.5 12.5 C35-50/60C EL195UH090XE48C 826816214ACX-036-230 TXV 34800 16 13 C35-50/60C EL195UH110XE60C 826816414ACX-036-230 TXV 34400 15.5 12.5 C35-50/60C EL296UH090XE48C 826816314ACX-036-230 TXV 34800 16 13 C35-50/60C EL296UH090XV36C 826816614ACX-036-230 TXV 34600 16 13 C35-50/60C EL296UH090XV48C 826815614ACX-036-230 TXV 34800 16 13 C35-50/60C EL296UH110XE60C 826816514ACX-036-230 TXV 34800 16 13 C35-50/60C EL296UH110XV48C 826815814ACX-036-230 TXV 35200 16 13 C35-50/60C EL296UH110XV60C 826815914ACX-036-230 TXV 35200 16 13 C35-50/60C SL280UH090V60C 826816714ACX-036-230 TXV 35200 16 13 C35-50/60C SL280UH090XV60C 826816814ACX-036-230 TXV 35000 16 13 C35-50/60C SL280UH110V60C 826816914ACX-036-230 TXV 35000 16 13 C35-50/60C SL280UH110XV60C 826817014ACX-036-230 TXV 34800 16 13 C35-50/60C SLP98UH090XV36C 826815514ACX-036-230 TXV 34600 16 13 C35-50/60C SLP98UH090XV48C 826815714ACX-036-230 TXV 35200 16 13 C35-50/60C SLP98UH110XV60C 826816014ACX-036-230 TXV 34200 14.5 12.2 C35-50/60C 826815414ACX-036-230 TXV 34600 16 13 CBA27UHE-036 1025947814ACX-036-230 TXV 35600 16 13 CBA27UHE-042 1025937814ACX-036-230 TXV 34200 14.5 12.2 CBX25UH-036 751038814ACX-036-230 TXV 34600 15 12.5 CBX25UH-042 751038914ACX-036-230 TXV 34400 15 12.5 CBX25UHV-036 751039014ACX-036-230 TXV 35200 16 13 CBX25UHV-042 751039114ACX-036-230 TXV 34200 16 13 CBX27UH-036 751039214ACX-036-230 TXV 35200 16 13 CBX27UH-042 751039314ACX-036-230 TXV 33400 14.5 12.2 CBX32M-030 751039414ACX-036-230 TXV 33800 14.5 12.2 CBX32M-036 751039514ACX-036-230 TXV 33800 14.5 12.2 CBX32M-042 751039614ACX-036-230 TXV 34800 15.1 12.5 CBX32M-048 751039714ACX-036-230 TXV 34000 15.1 12.5 CBX32MV-036 751039814ACX-036-230 TXV 35200 16 13 CBX32MV-048 751039914ACX-036-230 TXV 34200 15.1 12.5 CBX40UHV-036 751040014ACX-036-230 TXV 35000 15.5 12.5 CBX40UHV-042 751040114ACX-036-230 TXV 35000 16 13 CBX40UHV-048 751040214ACX-036-230 TXV 33600 15 12.5 CH23-41 EL180UH045E36A 751040614ACX-036-230 TXV 33600 15 12.5 CH23-41 EL180UH045XE36A 751040714ACX-036-230 TXV 33800 15.5 12.5 CH23-41 EL180UH070E36B 751040814ACX-036-230 TXV 33800 15.5 12.5 CH23-41 EL180UH070XE36B 7510409NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 106

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-036-230 TXV 33800 15.5 12.5 CH23-41 EL180UH090E48B 751041014ACX-036-230 TXV 33800 15.5 12.5 CH23-41 EL180UH090XE48B 751041114ACX-036-230 TXV 33600 15.1 12.5 CH23-41 EL195UH045XE36B 751041214ACX-036-230 TXV 33800 15.1 12.5 CH23-41 EL195UH070XE36B 751041414ACX-036-230 TXV 33600 15.1 12.5 CH23-41 EL296UH045XE36B 751041314ACX-036-230 TXV 33800 15.1 12.5 CH23-41 EL296UH045XV36B 751041614ACX-036-230 TXV 33800 15.1 12.5 CH23-41 EL296UH070XE36B 751041514ACX-036-230 TXV 33800 15.1 12.5 CH23-41 EL296UH070XV36B 751041714ACX-036-230 TXV 34000 16 13 CH23-41 SL280UH090V48B 751040414ACX-036-230 TXV 34000 16 13 CH23-41 SL280UH090XV48B 751040514ACX-036-230 TXV 33800 15.1 12.5 CH23-41 SLP98UH070XV36B 751041814ACX-036-230 TXV 33600 15 12.5 CH23-51 EL180UH045E36A 751042314ACX-036-230 TXV 33600 15 12.5 CH23-51 EL180UH045XE36A 751042414ACX-036-230 TXV 33800 15.5 12.5 CH23-51 EL180UH070E36B 751042514ACX-036-230 TXV 33800 15.5 12.5 CH23-51 EL180UH070XE36B 751042614ACX-036-230 TXV 33800 15.5 12.5 CH23-51 EL180UH090E48B 751042714ACX-036-230 TXV 34000 15.5 12.5 CH23-51 EL180UH090E60C 751043814ACX-036-230 TXV 33800 15.5 12.5 CH23-51 EL180UH090XE48B 751042814ACX-036-230 TXV 34000 15.5 12.5 CH23-51 EL180UH110E60C 751043914ACX-036-230 TXV 34000 15.5 12.5 CH23-51 EL180UH110XE60C 751044014ACX-036-230 TXV 33600 15.1 12.5 CH23-51 EL195UH045XE36B 751042914ACX-036-230 TXV 33800 15.1 12.5 CH23-51 EL195UH070XE36B 751043114ACX-036-230 TXV 33600 15.1 12.5 CH23-51 EL195UH090XE48C 751044114ACX-036-230 TXV 34000 15.5 12.5 CH23-51 EL195UH110XE60C 751044314ACX-036-230 TXV 33600 15.1 12.5 CH23-51 EL296UH045XE36B 751043014ACX-036-230 TXV 34000 15.1 12.5 CH23-51 EL296UH045XV36B 751043314ACX-036-230 TXV 33800 15.1 12.5 CH23-51 EL296UH070XE36B 751043214ACX-036-230 TXV 34000 15.1 12.5 CH23-51 EL296UH070XV36B 751043414ACX-036-230 TXV 33600 15.1 12.5 CH23-51 EL296UH090XE48C 751044214ACX-036-230 TXV 34000 15.5 12.5 CH23-51 EL296UH090XV36C 751044514ACX-036-230 TXV 33800 15.5 12.5 CH23-51 EL296UH090XV48C 751044714ACX-036-230 TXV 34000 15.5 12.5 CH23-51 EL296UH110XE60C 751044414ACX-036-230 TXV 34000 15.5 12.5 CH23-51 EL296UH110XV48C 751044914ACX-036-230 TXV 34200 15.5 12.5 CH23-51 EL296UH110XV60C 751045014ACX-036-230 TXV 34000 16 13 CH23-51 SL280UH090V36B 751042014ACX-036-230 TXV 34200 16 13 CH23-51 SL280UH090V48B 751042114ACX-036-230 TXV 34400 15.5 12.5 CH23-51 SL280UH090V60C 751317114ACX-036-230 TXV 34200 16 13 CH23-51 SL280UH090XV48B 751042214ACX-036-230 TXV 34400 15.5 12.5 CH23-51 SL280UH090XV60C 751317214ACX-036-230 TXV 34200 15.5 12.5 CH23-51 SL280UH110V60C 751043614ACX-036-230 TXV 34200 15.5 12.5 CH23-51 SL280UH110XV60C 751043714ACX-036-230 TXV 34000 15.1 12.5 CH23-51 SLP98UH070XV36B 751043514ACX-036-230 TXV 34000 15.5 12.5 CH23-51 SLP98UH090XV36C 751044614ACX-036-230 TXV 33800 15.5 12.5 CH23-51 SLP98UH090XV48C 751044814ACX-036-230 TXV 34200 15.5 12.5 CH23-51 SLP98UH110XV60C 751045114ACX-036-230 TXV 34000 15 12.5 CH33-31A EL180UH045E36A 751045414ACX-036-230 TXV 34000 15 12.5 CH33-31A EL180UH045XE36A 751045514ACX-036-230 TXV 34200 15.1 12.5 CH33-31A SL280UH070V36A 751045214ACX-036-230 TXV 34200 15.1 12.5 CH33-31A SL280UH070XV36A 7510453NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 107

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-036-230 TXV 34600 15.1 12.5 CH33-31B EL180UH070E36B 751046114ACX-036-230 TXV 34600 15.1 12.5 CH33-31B EL180UH070XE36B 751046214ACX-036-230 TXV 34600 15.5 12.5 CH33-31B EL180UH090E48B 751046314ACX-036-230 TXV 34600 15.5 12.5 CH33-31B EL180UH090XE48B 751046414ACX-036-230 TXV 34200 14.5 12.2 CH33-31B EL195UH045XE36B 751046514ACX-036-230 TXV 34400 15 12.5 CH33-31B EL195UH070XE36B 751046714ACX-036-230 TXV 34200 14.5 12.2 CH33-31B EL296UH045XE36B 751046614ACX-036-230 TXV 34600 15.1 12.5 CH33-31B EL296UH045XV36B 751046914ACX-036-230 TXV 34400 15 12.5 CH33-31B EL296UH070XE36B 751046814ACX-036-230 TXV 34600 15.1 12.5 CH33-31B EL296UH070XV36B 751047014ACX-036-230 TXV 34800 16 13 CH33-31B SL280UH090V36B 751045814ACX-036-230 TXV 34800 15.5 12.5 CH33-31B SL280UH090V48B 751045914ACX-036-230 TXV 34800 15.5 12.5 CH33-31B SL280UH090XV48B 751046014ACX-036-230 TXV 34600 15.1 12.5 CH33-31B SLP98UH070XV36B 751047114ACX-036-230 TXV 34200 14.5 12.2 CH33-31B 751045714ACX-036-230 TXV 33000 14.5 12.2 CH33-36A EL180UH045E36A 751047414ACX-036-230 TXV 33000 14.5 12.2 CH33-36A EL180UH045XE36A 751047514ACX-036-230 TXV 33200 14.5 12.2 CH33-36A SL280UH070V36A 751047214ACX-036-230 TXV 33200 14.5 12.2 CH33-36A SL280UH070XV36A 751047314ACX-036-230 TXV 33400 15.5 12.5 CH33-36B EL180UH070E36B 751048014ACX-036-230 TXV 33400 15.5 12.5 CH33-36B EL180UH070XE36B 751048114ACX-036-230 TXV 33400 15.1 12.5 CH33-36B EL180UH090E48B 751048214ACX-036-230 TXV 33400 15.1 12.5 CH33-36B EL180UH090XE48B 751048314ACX-036-230 TXV 33000 15 12.5 CH33-36B EL195UH045XE36B 751048414ACX-036-230 TXV 33200 15 12.5 CH33-36B EL195UH070XE36B 751048614ACX-036-230 TXV 33000 15 12.5 CH33-36B EL296UH045XE36B 751048514ACX-036-230 TXV 33400 14.5 12.2 CH33-36B EL296UH045XV36B 751317314ACX-036-230 TXV 33200 15 12.5 CH33-36B EL296UH070XE36B 751048714ACX-036-230 TXV 33400 15 12.5 CH33-36B EL296UH070XV36B 751048814ACX-036-230 TXV 33400 15.5 12.5 CH33-36B SL280UH090V36B 751047714ACX-036-230 TXV 33600 15.5 12.5 CH33-36B SL280UH090V48B 751047814ACX-036-230 TXV 33600 15.5 12.5 CH33-36B SL280UH090XV48B 751047914ACX-036-230 TXV 33400 15 12.5 CH33-36B SLP98UH070XV36B 751048914ACX-036-230 TXV 33800 15.5 12.5 CH33-36C EL180UH090E60C 751049314ACX-036-230 TXV 33800 15.5 12.5 CH33-36C EL180UH110E60C 751049414ACX-036-230 TXV 33800 15.5 12.5 CH33-36C EL180UH110XE60C 751049514ACX-036-230 TXV 33600 15.1 12.5 CH33-36C EL195UH090XE48C 751049614ACX-036-230 TXV 34000 15.5 12.5 CH33-36C EL195UH110XE60C 751049814ACX-036-230 TXV 33600 15.1 12.5 CH33-36C EL296UH090XE48C 751049714ACX-036-230 TXV 34000 15.5 12.5 CH33-36C EL296UH090XV36C 751050014ACX-036-230 TXV 33800 15.5 12.5 CH33-36C EL296UH090XV48C 751050214ACX-036-230 TXV 34000 15.5 12.5 CH33-36C EL296UH110XE60C 751049914ACX-036-230 TXV 34000 15.5 12.5 CH33-36C EL296UH110XV48C 751050414ACX-036-230 TXV 34200 15.5 12.5 CH33-36C EL296UH110XV60C 751050514ACX-036-230 TXV 34400 15.5 12.5 CH33-36C SL280UH090V60C 751317514ACX-036-230 TXV 34400 15.5 12.5 CH33-36C SL280UH090XV60C 751317714ACX-036-230 TXV 34200 15.5 12.5 CH33-36C SL280UH110V60C 751049114ACX-036-230 TXV 34200 15.5 12.5 CH33-36C SL280UH110XV60C 751049214ACX-036-230 TXV 34000 15.5 12.5 CH33-36C SLP98UH090XV36C 7510501NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 108

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-036-230 TXV 33800 15.5 12.5 CH33-36C SLP98UH090XV48C 751050314ACX-036-230 TXV 34200 15.5 12.5 CH33-36C SLP98UH110XV60C 751050614ACX-036-230 TXV 34200 15 12.5 CH33-42B EL180UH070E36B 751318114ACX-036-230 TXV 34200 15 12.5 CH33-42B EL180UH070XE36B 751318214ACX-036-230 TXV 34200 15.5 12.5 CH33-42B EL180UH090E48B 751318314ACX-036-230 TXV 34200 15.5 12.5 CH33-42B EL180UH090XE48B 751318414ACX-036-230 TXV 34000 14.5 12.2 CH33-42B EL195UH045XE36B 751318514ACX-036-230 TXV 34000 15.1 12.5 CH33-42B EL195UH070XE36B 751318714ACX-036-230 TXV 34000 14.5 12.2 CH33-42B EL296UH045XE36B 751318614ACX-036-230 TXV 34200 15 12.5 CH33-42B EL296UH045XV36B 751318914ACX-036-230 TXV 34000 15.1 12.5 CH33-42B EL296UH070XE36B 751318814ACX-036-230 TXV 34200 15.1 12.5 CH33-42B EL296UH070XV36B 751319014ACX-036-230 TXV 34400 15.5 12.5 CH33-42B SL280UH090V36B 751317814ACX-036-230 TXV 34400 15.5 12.5 CH33-42B SL280UH090V48B 751317914ACX-036-230 TXV 34400 15.5 12.5 CH33-42B SL280UH090XV48B 751318014ACX-036-230 TXV 34200 15.1 12.5 CH33-42B SLP98UH070XV36B 751319114ACX-036-230 TXV 35000 16 13 CH33-43B EL180UH070E36B 751051214ACX-036-230 TXV 35000 16 13 CH33-43B EL180UH070XE36B 751051314ACX-036-230 TXV 35400 16 13 CH33-43B EL180UH090E48B 751051414ACX-036-230 TXV 35400 16 13 CH33-43B EL180UH090XE48B 751051514ACX-036-230 TXV 35000 15.1 12.5 CH33-43B EL195UH045XE36B 751051614ACX-036-230 TXV 35000 15.1 12.5 CH33-43B EL195UH070XE36B 751051814ACX-036-230 TXV 35000 15.1 12.5 CH33-43B EL296UH045XE36B 751051714ACX-036-230 TXV 35400 15.5 12.5 CH33-43B EL296UH045XV36B 751052014ACX-036-230 TXV 35000 15.1 12.5 CH33-43B EL296UH070XE36B 751051914ACX-036-230 TXV 35400 15.5 12.5 CH33-43B EL296UH070XV36B 751052114ACX-036-230 TXV 35400 16 13 CH33-43B SL280UH090V36B 751050914ACX-036-230 TXV 35400 16 13 CH33-43B SL280UH090V48B 751051014ACX-036-230 TXV 35400 16 13 CH33-43B SL280UH090XV48B 751051114ACX-036-230 TXV 35400 15.5 12.5 CH33-43B SLP98UH070XV36B 751052214ACX-036-230 TXV 35000 14.5 12.2 CH33-43B 751050814ACX-036-230 TXV 35000 16 13 CH33-43C EL180UH090E60C 751052714ACX-036-230 TXV 35000 16 13 CH33-43C EL180UH110E60C 751052814ACX-036-230 TXV 35000 16 13 CH33-43C EL180UH110XE60C 751052914ACX-036-230 TXV 34800 16 13 CH33-43C EL195UH090XE48C 751053014ACX-036-230 TXV 35000 16 13 CH33-43C EL195UH110XE60C 751053214ACX-036-230 TXV 34800 16 13 CH33-43C EL296UH090XE48C 751053114ACX-036-230 TXV 35000 16 13 CH33-43C EL296UH090XV36C 751053414ACX-036-230 TXV 35000 16 13 CH33-43C EL296UH090XV48C 751053614ACX-036-230 TXV 35000 16 13 CH33-43C EL296UH110XE60C 751053314ACX-036-230 TXV 35200 16 13 CH33-43C EL296UH110XV48C 751053814ACX-036-230 TXV 35400 16 13 CH33-43C EL296UH110XV60C 751053914ACX-036-230 TXV 35600 16 13 CH33-43C SL280UH090V60C 751052314ACX-036-230 TXV 35600 16 13 CH33-43C SL280UH090XV60C 751052414ACX-036-230 TXV 35400 16 13 CH33-43C SL280UH110V60C 751052514ACX-036-230 TXV 35400 16 13 CH33-43C SL280UH110XV60C 751052614ACX-036-230 TXV 35000 16 13 CH33-43C SLP98UH090XV36C 751053514ACX-036-230 TXV 35000 16 13 CH33-43C SLP98UH090XV48C 751053714ACX-036-230 TXV 35400 16 13 CH33-43C SLP98UH110XV60C 7510540NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 109

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-036-230 TXV 34600 15.1 12.5 CH33-44/48B EL180UH070E36B 751054614ACX-036-230 TXV 34600 15.1 12.5 CH33-44/48B EL180UH070XE36B 751054714ACX-036-230 TXV 34600 15.5 12.5 CH33-44/48B EL180UH090E48B 751054814ACX-036-230 TXV 34600 15.5 12.5 CH33-44/48B EL180UH090XE48B 751054914ACX-036-230 TXV 34400 14.5 12.2 CH33-44/48B EL195UH045XE36B 751055014ACX-036-230 TXV 34400 15 12.5 CH33-44/48B EL195UH070XE36B 751055214ACX-036-230 TXV 34400 14.5 12.2 CH33-44/48B EL296UH045XE36B 751055114ACX-036-230 TXV 34600 15.1 12.5 CH33-44/48B EL296UH045XV36B 751055414ACX-036-230 TXV 34400 15 12.5 CH33-44/48B EL296UH070XE36B 751055314ACX-036-230 TXV 34600 15.1 12.5 CH33-44/48B EL296UH070XV36B 751055514ACX-036-230 TXV 34800 16 13 CH33-44/48B SL280UH090V36B 751054314ACX-036-230 TXV 34800 15.5 12.5 CH33-44/48B SL280UH090V48B 751054414ACX-036-230 TXV 34800 15.5 12.5 CH33-44/48B SL280UH090XV48B 751054514ACX-036-230 TXV 34600 15.1 12.5 CH33-44/48B SLP98UH070XV36B 751055614ACX-036-230 TXV 34200 14.5 12.2 CH33-44/48B 751054214ACX-036-230 TXV 34800 16 13 CH33-48C EL180UH090E60C 751056214ACX-036-230 TXV 34800 16 13 CH33-48C EL180UH110E60C 751056314ACX-036-230 TXV 34800 16 13 CH33-48C EL180UH110XE60C 751056414ACX-036-230 TXV 34600 15.5 12.5 CH33-48C EL195UH090XE48C 751056514ACX-036-230 TXV 35000 16 13 CH33-48C EL195UH110XE60C 751056714ACX-036-230 TXV 34600 15.5 12.5 CH33-48C EL296UH090XE48C 751056614ACX-036-230 TXV 35000 16 13 CH33-48C EL296UH090XV36C 751056914ACX-036-230 TXV 34800 16 13 CH33-48C EL296UH090XV48C 751057114ACX-036-230 TXV 35000 16 13 CH33-48C EL296UH110XE60C 751056814ACX-036-230 TXV 35000 16 13 CH33-48C EL296UH110XV48C 751057314ACX-036-230 TXV 35200 16 13 CH33-48C EL296UH110XV60C 751057414ACX-036-230 TXV 35400 16 13 CH33-48C SL280UH090V60C 751055814ACX-036-230 TXV 35400 16 13 CH33-48C SL280UH090XV60C 751055914ACX-036-230 TXV 35200 16 13 CH33-48C SL280UH110V60C 751056014ACX-036-230 TXV 35200 16 13 CH33-48C SL280UH110XV60C 751056114ACX-036-230 TXV 35000 16 13 CH33-48C SLP98UH090XV36C 751057014ACX-036-230 TXV 34800 16 13 CH33-48C SLP98UH090XV48C 751057214ACX-036-230 TXV 35200 16 13 CH33-48C SLP98UH110XV60C 751057514ACX-036-230 TXV 34400 14.5 12.2 CH33-48C 751055714ACX-036-230 TXV 35400 16 13 CH33-49 EL180UH090E60C 751319914ACX-036-230 TXV 35400 16 13 CH33-49 EL180UH110E60C 751320014ACX-036-230 TXV 35400 16 13 CH33-49 EL180UH110XE60C 751320114ACX-036-230 TXV 35000 16 13 CH33-49 EL195UH090XE48C 751320214ACX-036-230 TXV 35400 16 13 CH33-49 EL195UH110XE60C 751320414ACX-036-230 TXV 35000 16 13 CH33-49 EL296UH090XE48C 751320314ACX-036-230 TXV 35400 16 13 CH33-49 EL296UH090XV36C 751320614ACX-036-230 TXV 35200 16 13 CH33-49 EL296UH090XV48C 751320814ACX-036-230 TXV 35400 16 13 CH33-49 EL296UH110XE60C 751320514ACX-036-230 TXV 35400 16 13 CH33-49 EL296UH110XV48C 751321014ACX-036-230 TXV 35800 16 13 CH33-49 EL296UH110XV60C 751321114ACX-036-230 TXV 35800 16 13 CH33-49 SL280UH090V60C 751319514ACX-036-230 TXV 35800 16 13 CH33-49 SL280UH090XV60C 751319614ACX-036-230 TXV 35600 16 13 CH33-49 SL280UH110V60C 751319714ACX-036-230 TXV 35600 16 13 CH33-49 SL280UH110XV60C 7513198NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 110

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-036-230 TXV 35400 16 13 CH33-49 SLP98UH090XV36C 751320714ACX-036-230 TXV 35200 16 13 CH33-49 SLP98UH090XV48C 751320914ACX-036-230 TXV 35800 16 13 CH33-49 SLP98UH110XV60C 751321214ACX-036-230 TXV 34800 14.5 12.2 CH33-49 751319414ACX-036-230 TXV 35200 16 13 CH33-50/60C EL180UH090E60C 751058014ACX-036-230 TXV 35200 16 13 CH33-50/60C EL180UH110E60C 751058114ACX-036-230 TXV 35200 16 13 CH33-50/60C EL180UH110XE60C 751058214ACX-036-230 TXV 35000 16 13 CH33-50/60C EL195UH090XE48C 751058314ACX-036-230 TXV 35200 16 13 CH33-50/60C EL195UH110XE60C 751058514ACX-036-230 TXV 35000 16 13 CH33-50/60C EL296UH090XE48C 751058414ACX-036-230 TXV 35200 16 13 CH33-50/60C EL296UH090XV36C 751058714ACX-036-230 TXV 35000 16 13 CH33-50/60C EL296UH090XV48C 751058914ACX-036-230 TXV 35200 16 13 CH33-50/60C EL296UH110XE60C 751058614ACX-036-230 TXV 35200 16 13 CH33-50/60C EL296UH110XV48C 751059114ACX-036-230 TXV 35600 16 13 CH33-50/60C EL296UH110XV60C 751059214ACX-036-230 TXV 35600 16 13 CH33-50/60C SL280UH090V60C 751057614ACX-036-230 TXV 35600 16 13 CH33-50/60C SL280UH090XV60C 751057714ACX-036-230 TXV 35600 16 13 CH33-50/60C SL280UH110V60C 751057814ACX-036-230 TXV 35600 16 13 CH33-50/60C SL280UH110XV60C 751057914ACX-036-230 TXV 35200 16 13 CH33-50/60C SLP98UH090XV36C 751058814ACX-036-230 TXV 35000 16 13 CH33-50/60C SLP98UH090XV48C 751059014ACX-036-230 TXV 35600 16 13 CH33-50/60C SLP98UH110XV60C 751059314ACX-036-230 TXV 34600 14.5 12.2 CH33-50/60C 751059514ACX-036-230 TXV 34000 15 12.5 CH35-30A EL180UH045E36A 751059814ACX-036-230 TXV 34000 15 12.5 CH35-30A EL180UH045XE36A 751059914ACX-036-230 TXV 34200 15.1 12.5 CH35-30A SL280UH070V36A 751059614ACX-036-230 TXV 34200 15.1 12.5 CH35-30A SL280UH070XV36A 751059714ACX-036-230 TXV 34800 15.1 12.5 CH35-30B EL180UH070E36B 751060514ACX-036-230 TXV 34800 15.1 12.5 CH35-30B EL180UH070XE36B 751060614ACX-036-230 TXV 34800 16 13 CH35-30B EL180UH090E48B 751060714ACX-036-230 TXV 34800 16 13 CH35-30B EL180UH090XE48B 751060814ACX-036-230 TXV 34400 14.5 12.2 CH35-30B EL195UH045XE36B 751060914ACX-036-230 TXV 34400 15 12.5 CH35-30B EL195UH070XE36B 751061114ACX-036-230 TXV 34400 14.5 12.2 CH35-30B EL296UH045XE36B 751061014ACX-036-230 TXV 34600 15.1 12.5 CH35-30B EL296UH045XV36B 751061314ACX-036-230 TXV 34400 15 12.5 CH35-30B EL296UH070XE36B 751061214ACX-036-230 TXV 34600 15.1 12.5 CH35-30B EL296UH070XV36B 751061414ACX-036-230 TXV 34800 16 13 CH35-30B SL280UH090V36B 751060214ACX-036-230 TXV 34800 15.5 12.5 CH35-30B SL280UH090V48B 751060314ACX-036-230 TXV 34800 15.5 12.5 CH35-30B SL280UH090XV48B 751060414ACX-036-230 TXV 34600 15.1 12.5 CH35-30B SLP98UH070XV36B 751061514ACX-036-230 TXV 34200 14.5 12.2 CH35-30B 751060114ACX-036-230 TXV 33000 14.5 12.2 CH35-36A EL180UH045E36A 751061814ACX-036-230 TXV 33000 14.5 12.2 CH35-36A EL180UH045XE36A 751061914ACX-036-230 TXV 33200 14.5 12.2 CH35-36A SL280UH070V36A 751061614ACX-036-230 TXV 33200 14.5 12.2 CH35-36A SL280UH070XV36A 751061714ACX-036-230 TXV 33400 15.5 12.5 CH35-36B EL180UH070E36B 751062414ACX-036-230 TXV 33400 15.5 12.5 CH35-36B EL180UH070XE36B 751062514ACX-036-230 TXV 33400 15.1 12.5 CH35-36B EL180UH090E48B 7510626NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 111

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-036-230 TXV 33400 15.1 12.5 CH35-36B EL180UH090XE48B 751062714ACX-036-230 TXV 33000 15 12.5 CH35-36B EL195UH045XE36B 751062814ACX-036-230 TXV 33000 15 12.5 CH35-36B EL296UH045XE36B 751062914ACX-036-230 TXV 33600 15 12.2 CH35-36B EL296UH045XV36B 751063214ACX-036-230 TXV 33400 15 12.5 CH35-36B EL296UH070XV36B 751063314ACX-036-230 TXV 33600 15.5 12.5 CH35-36B SL280UH090V36B 751062114ACX-036-230 TXV 33800 15.5 12.5 CH35-36B SL280UH090V48B 751062214ACX-036-230 TXV 33800 15.5 12.5 CH35-36B SL280UH090XV48B 751062314ACX-036-230 TXV 33400 15 12.5 CH35-36B SLP98UH070XV36B 751063414ACX-036-230 TXV 34000 15.5 12.5 CH35-36C EL180UH090E60C 751063814ACX-036-230 TXV 33800 15.5 12.5 CH35-36C EL180UH110E60C 751063914ACX-036-230 TXV 33800 15.5 12.5 CH35-36C EL180UH110XE60C 751064014ACX-036-230 TXV 33600 15.1 12.5 CH35-36C EL195UH090XE48C 751064114ACX-036-230 TXV 34000 15.5 12.5 CH35-36C EL195UH110XE60C 751064314ACX-036-230 TXV 33600 15.1 12.5 CH35-36C EL296UH090XE48C 751064214ACX-036-230 TXV 34000 15.5 12.5 CH35-36C EL296UH090XV36C 751064514ACX-036-230 TXV 33800 15.5 12.5 CH35-36C EL296UH090XV48C 751064714ACX-036-230 TXV 34000 15.5 12.5 CH35-36C EL296UH110XE60C 751064414ACX-036-230 TXV 34000 15.5 12.5 CH35-36C EL296UH110XV48C 751064914ACX-036-230 TXV 34400 15.5 12.5 CH35-36C EL296UH110XV60C 751321514ACX-036-230 TXV 34400 15.5 12.5 CH35-36C SL280UH090V60C 751321314ACX-036-230 TXV 34400 15.5 12.5 CH35-36C SL280UH090XV60C 751321414ACX-036-230 TXV 34200 15.5 12.5 CH35-36C SL280UH110V60C 751063614ACX-036-230 TXV 34200 15.5 12.5 CH35-36C SL280UH110XV60C 751063714ACX-036-230 TXV 34000 15.5 12.5 CH35-36C SLP98UH090XV36C 751064614ACX-036-230 TXV 33800 15.5 12.5 CH35-36C SLP98UH090XV48C 751064814ACX-036-230 TXV 34400 15.5 12.5 CH35-36C SLP98UH110XV60C 751065014ACX-036-230 TXV 35000 16 13 CH35-42B EL180UH070E36B 751065514ACX-036-230 TXV 35000 16 13 CH35-42B EL180UH070XE36B 751065614ACX-036-230 TXV 35400 16 13 CH35-42B EL180UH090E48B 751065714ACX-036-230 TXV 35400 16 13 CH35-42B EL180UH090XE48B 751065814ACX-036-230 TXV 35000 15.1 12.5 CH35-42B EL195UH045XE36B 751065914ACX-036-230 TXV 35200 15.1 12.5 CH35-42B EL195UH070XE36B 751066114ACX-036-230 TXV 35000 15.1 12.5 CH35-42B EL296UH045XE36B 751066014ACX-036-230 TXV 35400 15.5 12.5 CH35-42B EL296UH045XV36B 751066314ACX-036-230 TXV 35200 15.1 12.5 CH35-42B EL296UH070XE36B 751066214ACX-036-230 TXV 35400 15.5 12.5 CH35-42B EL296UH070XV36B 751066414ACX-036-230 TXV 35400 16 13 CH35-42B SL280UH090V36B 751065214ACX-036-230 TXV 35600 16 13 CH35-42B SL280UH090V48B 751065314ACX-036-230 TXV 35600 16 13 CH35-42B SL280UH090XV48B 751065414ACX-036-230 TXV 35400 15.5 12.5 CH35-42B SLP98UH070XV36B 751066514ACX-036-230 TXV 35000 14.5 12.2 CH35-42B 751065114ACX-036-230 TXV 35200 16 13 CH35-42C EL180UH090E60C 751067114ACX-036-230 TXV 35000 16 13 CH35-42C EL180UH110E60C 751067214ACX-036-230 TXV 35000 16 13 CH35-42C EL180UH110XE60C 751067314ACX-036-230 TXV 34800 16 13 CH35-42C EL195UH090XE48C 751067414ACX-036-230 TXV 35200 16 13 CH35-42C EL195UH110XE60C 751067614ACX-036-230 TXV 34800 16 13 CH35-42C EL296UH090XE48C 751067514ACX-036-230 TXV 35200 16 13 CH35-42C EL296UH090XV36C 7510678NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 112

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-036-230 TXV 35000 16 13 CH35-42C EL296UH090XV48C 751068014ACX-036-230 TXV 35200 16 13 CH35-42C EL296UH110XE60C 751067714ACX-036-230 TXV 35200 16 13 CH35-42C EL296UH110XV48C 751068214ACX-036-230 TXV 35400 16 13 CH35-42C EL296UH110XV60C 751068314ACX-036-230 TXV 35600 16 13 CH35-42C SL280UH090V60C 751066714ACX-036-230 TXV 35600 16 13 CH35-42C SL280UH090XV60C 751066814ACX-036-230 TXV 35400 16 13 CH35-42C SL280UH110V60C 751066914ACX-036-230 TXV 35400 16 13 CH35-42C SL280UH110XV60C 751067014ACX-036-230 TXV 35200 16 13 CH35-42C SLP98UH090XV36C 751067914ACX-036-230 TXV 35000 16 13 CH35-42C SLP98UH090XV48C 751068114ACX-036-230 TXV 35400 16 13 CH35-42C SLP98UH110XV60C 751068414ACX-036-230 TXV 34600 14.5 12.2 CH35-42C 751066614ACX-036-230 TXV 34800 15.1 12.5 CH35-48B EL180UH070E36B 751068914ACX-036-230 TXV 34800 15.1 12.5 CH35-48B EL180UH070XE36B 751069014ACX-036-230 TXV 34800 16 13 CH35-48B EL180UH090E48B 751069114ACX-036-230 TXV 34800 16 13 CH35-48B EL180UH090XE48B 751069214ACX-036-230 TXV 34400 15 12.2 CH35-48B EL195UH045XE36B 751069314ACX-036-230 TXV 34600 15 12.5 CH35-48B EL195UH070XE36B 751069514ACX-036-230 TXV 34400 15 12.2 CH35-48B EL296UH045XE36B 751069414ACX-036-230 TXV 35000 15.1 12.5 CH35-48B EL296UH045XV36B 751069714ACX-036-230 TXV 34600 15 12.5 CH35-48B EL296UH070XE36B 751069614ACX-036-230 TXV 34800 15.5 12.5 CH35-48B EL296UH070XV36B 751069814ACX-036-230 TXV 35000 16 13 CH35-48B SL280UH090V36B 751068614ACX-036-230 TXV 35000 16 13 CH35-48B SL280UH090V48B 751068714ACX-036-230 TXV 35000 16 13 CH35-48B SL280UH090XV48B 751068814ACX-036-230 TXV 34800 15.5 12.5 CH35-48B SLP98UH070XV36B 751069914ACX-036-230 TXV 34400 14.5 12.2 CH35-48B 751068514ACX-036-230 TXV 35000 16 13 CH35-48C EL180UH090E60C 751070514ACX-036-230 TXV 35000 16 13 CH35-48C EL180UH110E60C 751070614ACX-036-230 TXV 35000 16 13 CH35-48C EL180UH110XE60C 751070714ACX-036-230 TXV 34800 16 13 CH35-48C EL195UH090XE48C 751070814ACX-036-230 TXV 35000 16 13 CH35-48C EL195UH110XE60C 751071014ACX-036-230 TXV 34800 16 13 CH35-48C EL296UH090XE48C 751070914ACX-036-230 TXV 35000 16 13 CH35-48C EL296UH090XV36C 751071214ACX-036-230 TXV 34800 16 13 CH35-48C EL296UH090XV48C 751071414ACX-036-230 TXV 35000 16 13 CH35-48C EL296UH110XE60C 751071114ACX-036-230 TXV 35000 16 13 CH35-48C EL296UH110XV48C 751071614ACX-036-230 TXV 35400 16 13 CH35-48C EL296UH110XV60C 751071714ACX-036-230 TXV 35400 16 13 CH35-48C SL280UH090V60C 751070114ACX-036-230 TXV 35400 16 13 CH35-48C SL280UH090XV60C 751070214ACX-036-230 TXV 35400 16 13 CH35-48C SL280UH110V60C 751070314ACX-036-230 TXV 35400 16 13 CH35-48C SL280UH110XV60C 751070414ACX-036-230 TXV 35000 16 13 CH35-48C SLP98UH090XV36C 751071314ACX-036-230 TXV 34800 16 13 CH35-48C SLP98UH090XV48C 751071514ACX-036-230 TXV 35400 16 13 CH35-48C SLP98UH110XV60C 751071814ACX-036-230 TXV 34400 14.5 12.2 CH35-48C 751070014ACX-036-230 TXV 35400 16 13 CH35-51C EL180UH090E60C 751072414ACX-036-230 TXV 35400 16 13 CH35-51C EL180UH110E60C 751072514ACX-036-230 TXV 35400 16 13 CH35-51C EL180UH110XE60C 7510726NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 113

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-036-230 TXV 35200 16 13 CH35-51C EL195UH090XE48C 751072714ACX-036-230 TXV 35400 16 13 CH35-51C EL195UH110XE60C 751072914ACX-036-230 TXV 35200 16 13 CH35-51C EL296UH090XE48C 751072814ACX-036-230 TXV 35400 16 13 CH35-51C EL296UH090XV36C 751073114ACX-036-230 TXV 35200 16 13 CH35-51C EL296UH090XV48C 751073314ACX-036-230 TXV 35400 16 13 CH35-51C EL296UH110XE60C 751073014ACX-036-230 TXV 35400 16 13 CH35-51C EL296UH110XV48C 751073514ACX-036-230 TXV 35800 16 13 CH35-51C EL296UH110XV60C 751073614ACX-036-230 TXV 36000 16 13 CH35-51C SL280UH090V60C 751072014ACX-036-230 TXV 36000 16 13 CH35-51C SL280UH090XV60C 751072114ACX-036-230 TXV 35800 16 13 CH35-51C SL280UH110V60C 751072214ACX-036-230 TXV 35800 16 13 CH35-51C SL280UH110XV60C 751072314ACX-036-230 TXV 35400 16 13 CH35-51C SLP98UH090XV36C 751073214ACX-036-230 TXV 35200 16 13 CH35-51C SLP98UH090XV48C 751073414ACX-036-230 TXV 35800 16 13 CH35-51C SLP98UH110XV60C 751073714ACX-036-230 TXV 34800 14.5 12.2 CH35-51C 751071914ACX-036-230 TXV 33600 14.5 12.2 CR33-30/36A EL180DF045E36A 751073914ACX-036-230 TXV 33600 15 12.5 CR33-30/36A SL280DF070V36A 751073814ACX-036-230 TXV 33600 15.5 12.5 CR33-30/36B EL180DF070E36B 751074214ACX-036-230 TXV 33600 15.1 12.5 CR33-30/36B EL180DF090E48B 751074314ACX-036-230 TXV 33600 15.1 12.5 CR33-30/36B EL195DF070XE48B 751074614ACX-036-230 TXV 33600 15 12.2 CR33-30/36B EL296DF045XV36B 751074814ACX-036-230 TXV 33600 15.1 12.5 CR33-30/36B EL296DF070XE48B 751074714ACX-036-230 TXV 33600 14.5 12.2 CR33-30/36B EL296DF070XV48B 751074914ACX-036-230 TXV 33800 15.1 12.5 CR33-30/36B SL280DF090V48B 751074114ACX-036-230 TXV 33800 15 12.5 CR33-30/36B SLP98DF070XV36B 751075014ACX-036-230 TXV 33800 15.5 12.5 CR33-30/36C EL180DF110E60C 751075314ACX-036-230 TXV 33600 15.1 12.5 CR33-30/36C EL195DF090XE48C 751075414ACX-036-230 TXV 33600 15.1 12.5 CR33-30/36C EL195DF110XE60C 751075614ACX-036-230 TXV 33600 15.1 12.5 CR33-30/36C EL296DF090XE48C 761539214ACX-036-230 TXV 34000 15.1 12.5 CR33-30/36C EL296DF090XV60C 761539414ACX-036-230 TXV 33600 15.1 12.5 CR33-30/36C EL296DF110XE60C 761539314ACX-036-230 TXV 34000 15.1 12.5 CR33-30/36C EL296DF110XV60C 761539514ACX-036-230 TXV 34000 15.5 12.5 CR33-30/36C SL280DF110V60C 751075214ACX-036-230 TXV 33800 15.1 12.5 CR33-30/36C SLP98DF090XV36C 751075814ACX-036-230 TXV 33800 15.1 12.5 CR33-30/36C SLP98DF090XV48C 751075914ACX-036-230 TXV 34000 15.1 12.5 CR33-30/36C SLP98DF090XV60C 751076114ACX-036-230 TXV 34000 15.1 12.5 CR33-30/36C SLP98DF110XV60C 751076314ACX-036-230 TXV 34200 15 12.5 CR33-48B EL180DF070E36B 751321914ACX-036-230 TXV 34200 15.5 12.5 CR33-48B EL180DF090E48B 751322014ACX-036-230 TXV 34000 15.1 12.5 CR33-48B EL195DF045XE36B 751322114ACX-036-230 TXV 34000 15.5 12.5 CR33-48B EL195DF070XE48B 751322314ACX-036-230 TXV 34000 15.5 12.5 CR33-48B EL296DF045XE36B 751322214ACX-036-230 TXV 34200 15.1 12.5 CR33-48B EL296DF045XV36B 762267514ACX-036-230 TXV 34000 15.5 12.5 CR33-48B EL296DF070XE48B 751322414ACX-036-230 TXV 34200 15.1 12.5 CR33-48B EL296DF070XV48B 751322614ACX-036-230 TXV 34600 15.5 12.5 CR33-48B SL280DF090V48B 751321814ACX-036-230 TXV 34000 15.5 12.5 CR33-48B SLP98DF070XV36B 751322714ACX-036-230 TXV 34400 16 13 CR33-48C EL180DF110E60C 7513231NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 114

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-036-230 TXV 34200 15.5 12.5 CR33-48C EL195DF090XE48C 751323214ACX-036-230 TXV 34200 15.5 12.5 CR33-48C EL195DF110XE60C 751323414ACX-036-230 TXV 34200 15.5 12.5 CR33-48C EL296DF090XE48C 751323314ACX-036-230 TXV 34600 15.5 12.5 CR33-48C EL296DF090XV60C 751323814ACX-036-230 TXV 34200 15.5 12.5 CR33-48C EL296DF110XE60C 751323514ACX-036-230 TXV 34600 15.5 12.5 CR33-48C EL296DF110XV60C 751324014ACX-036-230 TXV 34600 16 13 CR33-48C SL280DF110V60C 751323014ACX-036-230 TXV 34400 15.5 12.5 CR33-48C SLP98DF090XV36C 751323614ACX-036-230 TXV 34400 16 13 CR33-48C SLP98DF090XV48C 751323714ACX-036-230 TXV 34600 15.5 12.5 CR33-48C SLP98DF090XV60C 751323914ACX-036-230 TXV 34600 15.5 12.5 CR33-48C SLP98DF110XV60C 751324114ACX-036-230 TXV 33200 14.5 12.2 CX35-30/36A EL180UH045E36A 826819114ACX-036-230 TXV 33200 14.5 12.2 CX35-30/36A EL180UH045XE36A 826819214ACX-036-230 TXV 33400 15 12.2 CX35-30/36A SL280UH070V36A 826819314ACX-036-230 TXV 33400 15 12.2 CX35-30/36A SL280UH070XV36A 826819414ACX-036-230 TXV 33400 15.5 12.5 CX35-30/36B EL180UH070E36B 826820614ACX-036-230 TXV 33400 15.5 12.5 CX35-30/36B EL180UH070XE36B 826819814ACX-036-230 TXV 33400 15.1 12.5 CX35-30/36B EL180UH090E48B 826819914ACX-036-230 TXV 33400 15.1 12.5 CX35-30/36B EL180UH090XE48B 826820014ACX-036-230 TXV 33000 15 12.5 CX35-30/36B EL195UH045XE36B 826820114ACX-036-230 TXV 33000 15 12.5 CX35-30/36B EL296UH045XE36B 826820214ACX-036-230 TXV 33400 15 12.5 CX35-30/36B EL296UH045XV36B 826819514ACX-036-230 TXV 33400 15 12.5 CX35-30/36B EL296UH070XV36B 826819614ACX-036-230 TXV 33600 15.5 12.5 CX35-30/36B SL280UH090V36B 826820314ACX-036-230 TXV 33600 15.5 12.5 CX35-30/36B SL280UH090V48B 826820414ACX-036-230 TXV 33600 15.5 12.5 CX35-30/36B SL280UH090XV48B 826820514ACX-036-230 TXV 33400 15 12.5 CX35-30/36B SLP98UH070XV36B 826819714ACX-036-230 TXV 33600 15.1 12.5 CX35-30/36C EL180UH090E60C 826821814ACX-036-230 TXV 33400 15.5 12.5 CX35-30/36C EL180UH110E60C 826821914ACX-036-230 TXV 33400 15.5 12.5 CX35-30/36C EL180UH110XE60C 826821214ACX-036-230 TXV 33200 15.1 12.5 CX35-30/36C EL195UH090XE48C 826821314ACX-036-230 TXV 33600 15.1 12.5 CX35-30/36C EL195UH110XE60C 826821514ACX-036-230 TXV 33200 15.1 12.5 CX35-30/36C EL296UH090XE48C 826821414ACX-036-230 TXV 33600 15.5 12.5 CX35-30/36C EL296UH090XV36C 826821714ACX-036-230 TXV 33400 15.5 12.5 CX35-30/36C EL296UH090XV48C 826820914ACX-036-230 TXV 33600 15.1 12.5 CX35-30/36C EL296UH110XE60C 826821614ACX-036-230 TXV 33600 15.5 12.5 CX35-30/36C EL296UH110XV48C 826821114ACX-036-230 TXV 33600 15.5 12.5 CX35-30/36C SLP98UH090XV36C 826820814ACX-036-230 TXV 33400 15.5 12.5 CX35-30/36C SLP98UH090XV48C 826821014ACX-036-230 TXV 33800 15.5 12.5 CX35-30/36C SLP98UH110XV60C 826820714ACX-036-230 TXV 34200 15.1 12.5 CX35-30A EL180UH045E36A 826817314ACX-036-230 TXV 34200 15.1 12.5 CX35-30A EL180UH045XE36A 826817414ACX-036-230 TXV 34400 15.1 12.5 CX35-30A SL280UH070V36A 826817514ACX-036-230 TXV 34400 15.1 12.5 CX35-30A SL280UH070XV36A 826817614ACX-036-230 TXV 34400 15 12.5 CX35-30B EL180UH070E36B 826819014ACX-036-230 TXV 34400 15 12.5 CX35-30B EL180UH070XE36B 826818114ACX-036-230 TXV 34400 15.5 12.5 CX35-30B EL180UH090E48B 826818214ACX-036-230 TXV 34400 15.5 12.5 CX35-30B EL180UH090XE48B 826818314ACX-036-230 TXV 34000 14.5 12.2 CX35-30B EL195UH045XE36B 8268184NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 115

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-036-230 TXV 34000 15.1 12.5 CX35-30B EL195UH070XE36B 826818614ACX-036-230 TXV 34000 14.5 12.2 CX35-30B EL296UH045XE36B 826818514ACX-036-230 TXV 34200 15.1 12.5 CX35-30B EL296UH045XV36B 826817814ACX-036-230 TXV 34000 15.1 12.5 CX35-30B EL296UH070XE36B 826817714ACX-036-230 TXV 34200 15.1 12.5 CX35-30B EL296UH070XV36B 826817914ACX-036-230 TXV 34400 15.5 12.5 CX35-30B SL280UH090V36B 826818714ACX-036-230 TXV 34400 15.5 12.5 CX35-30B SL280UH090V48B 826818814ACX-036-230 TXV 34400 15.5 12.5 CX35-30B SL280UH090XV48B 826818914ACX-036-230 TXV 34200 15.1 12.5 CX35-30B SLP98UH070XV36B 826818014ACX-036-230 TXV 34400 15.1 12.5 CX35-36A EL180UH045E36A 826822114ACX-036-230 TXV 34400 15.1 12.5 CX35-36A EL180UH045XE36A 826822214ACX-036-230 TXV 34600 15.5 12.5 CX35-36A SL280UH070V36A 826822314ACX-036-230 TXV 34600 15.5 12.5 CX35-36A SL280UH070XV36A 826822414ACX-036-230 TXV 34200 14.25 12.2 CX35-36A 826822014ACX-036-230 TXV 34600 16 13 CX35-36B EL180UH070E36B 826823914ACX-036-230 TXV 34600 16 13 CX35-36B EL180UH070XE36B 826823014ACX-036-230 TXV 34600 16 13 CX35-36B EL180UH090E48B 826823114ACX-036-230 TXV 34600 16 13 CX35-36B EL180UH090XE48B 826823214ACX-036-230 TXV 34400 15 12.5 CX35-36B EL195UH045XE36B 826823314ACX-036-230 TXV 34400 15 12.5 CX35-36B EL195UH070XE36B 826823514ACX-036-230 TXV 34400 15 12.5 CX35-36B EL296UH045XE36B 826823414ACX-036-230 TXV 34600 15.5 12.5 CX35-36B EL296UH045XV36B 826822714ACX-036-230 TXV 34400 15 12.5 CX35-36B EL296UH070XE36B 826822614ACX-036-230 TXV 34600 15.5 12.5 CX35-36B EL296UH070XV36B 826822814ACX-036-230 TXV 34800 16 13 CX35-36B SL280UH090V36B 826823614ACX-036-230 TXV 34800 16 13 CX35-36B SL280UH090V48B 826823714ACX-036-230 TXV 34800 16 13 CX35-36B SL280UH090XV48B 826823814ACX-036-230 TXV 34600 15.5 12.5 CX35-36B SLP98UH070XV36B 826822914ACX-036-230 TXV 34200 14.25 12.2 CX35-36B 826822514ACX-036-230 TXV 34800 16 13 CX35-48B EL180UH070E36B 826824814ACX-036-230 TXV 34800 16 13 CX35-48B EL180UH070XE36B 826824914ACX-036-230 TXV 34800 16 13 CX35-48B EL180UH090E48B 826825014ACX-036-230 TXV 34800 16 13 CX35-48B EL180UH090XE48B 826825114ACX-036-230 TXV 34400 15 12.5 CX35-48B EL195UH045XE36B 826825214ACX-036-230 TXV 34600 15.1 12.5 CX35-48B EL195UH070XE36B 826824214ACX-036-230 TXV 34400 15 12.5 CX35-48B EL296UH045XE36B 826824114ACX-036-230 TXV 34800 15.5 12.5 CX35-48B EL296UH045XV36B 826824414ACX-036-230 TXV 34600 15.1 12.5 CX35-48B EL296UH070XE36B 826824314ACX-036-230 TXV 34800 15.5 12.5 CX35-48B EL296UH070XV36B 826824514ACX-036-230 TXV 34800 16 13 CX35-48B SL280UH090V36B 826825314ACX-036-230 TXV 35000 16 13 CX35-48B SL280UH090V48B 826825414ACX-036-230 TXV 35000 16 13 CX35-48B SL280UH090XV48B 826824714ACX-036-230 TXV 34800 15.5 12.5 CX35-48B SLP98UH070XV36B 826824614ACX-036-230 TXV 34400 14.5 12.2 CX35-48B 826824014ACX-036-230 TXV 34800 16 13 CX35-48C EL180UH090E60C 826827214ACX-036-230 TXV 34800 16 13 CX35-48C EL180UH110E60C 826827314ACX-036-230 TXV 34800 16 13 CX35-48C EL180UH110XE60C 826826214ACX-036-230 TXV 34600 15.5 12.5 CX35-48C EL195UH090XE48C 826826314ACX-036-230 TXV 34800 16 13 CX35-48C EL195UH110XE60C 8268265NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 116

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-036-230 TXV 34600 15.5 12.5 CX35-48C EL296UH090XE48C 826826414ACX-036-230 TXV 34800 16 13 CX35-48C EL296UH090XV36C 826826714ACX-036-230 TXV 34800 16 13 CX35-48C EL296UH090XV48C 826825714ACX-036-230 TXV 34600 16 13 CX35-48C EL296UH110XE60C 826826614ACX-036-230 TXV 35000 16 13 CX35-48C EL296UH110XV48C 826825914ACX-036-230 TXV 35200 16 13 CX35-48C EL296UH110XV60C 826826014ACX-036-230 TXV 35400 16 13 CX35-48C SL280UH090V60C 826826814ACX-036-230 TXV 35400 16 13 CX35-48C SL280UH090XV60C 826826914ACX-036-230 TXV 35200 16 13 CX35-48C SL280UH110V60C 826827014ACX-036-230 TXV 35200 16 13 CX35-48C SL280UH110XV60C 826827114ACX-036-230 TXV 34800 16 13 CX35-48C SLP98UH090XV36C 826825614ACX-036-230 TXV 34800 16 13 CX35-48C SLP98UH090XV48C 826825814ACX-036-230 TXV 35200 16 13 CX35-48C SLP98UH110XV60C 826826114ACX-036-230 TXV 34400 14.5 12.2 CX35-48C 826825514ACX-036-230 TXV 35200 16 13 CX35-49C EL180UH090E60C 826828714ACX-036-230 TXV 35000 16 13 CX35-49C EL180UH110E60C 826828814ACX-036-230 TXV 35000 16 13 CX35-49C EL180UH110XE60C 826828914ACX-036-230 TXV 34800 16 13 CX35-49C EL195UH090XE48C 826829014ACX-036-230 TXV 35200 16 13 CX35-49C EL195UH110XE60C 826828014ACX-036-230 TXV 34800 16 13 CX35-49C EL296UH090XE48C 826827914ACX-036-230 TXV 35200 16 13 CX35-49C EL296UH090XV36C 826828214ACX-036-230 TXV 35000 16 13 CX35-49C EL296UH090XV48C 826828414ACX-036-230 TXV 35200 16 13 CX35-49C EL296UH110XE60C 826828114ACX-036-230 TXV 35200 16 13 CX35-49C EL296UH110XV48C 826827614ACX-036-230 TXV 35600 16 13 CX35-49C EL296UH110XV60C 826827714ACX-036-230 TXV 35600 16 13 CX35-49C SL280UH090V60C 826829114ACX-036-230 TXV 35600 16 13 CX35-49C SL280UH090XV60C 826829214ACX-036-230 TXV 35400 16 13 CX35-49C SL280UH110V60C 826828514ACX-036-230 TXV 35400 16 13 CX35-49C SL280UH110XV60C 826828614ACX-036-230 TXV 35200 16 13 CX35-49C SLP98UH090XV36C 826828314ACX-036-230 TXV 35000 16 13 CX35-49C SLP98UH090XV48C 826827514ACX-036-230 TXV 35600 16 13 CX35-49C SLP98UH110XV60C 826827814ACX-036-230 TXV 34600 14.5 12.2 CX35-49C 826827414ACX-036-230 TXV 34800 16 13 CX35-50/60C EL180UH090E60C 826830214ACX-036-230 TXV 34800 16 13 CX35-50/60C EL180UH110E60C 826830314ACX-036-230 TXV 34800 16 13 CX35-50/60C EL180UH110XE60C 826830414ACX-036-230 TXV 34400 15.5 12.5 CX35-50/60C EL195UH090XE48C 826830514ACX-036-230 TXV 34800 16 13 CX35-50/60C EL195UH110XE60C 826830714ACX-036-230 TXV 34400 15.5 12.5 CX35-50/60C EL296UH090XE48C 826830614ACX-036-230 TXV 34800 16 13 CX35-50/60C EL296UH090XV36C 826829714ACX-036-230 TXV 34600 16 13 CX35-50/60C EL296UH090XV48C 826829914ACX-036-230 TXV 34800 16 13 CX35-50/60C EL296UH110XE60C 826829614ACX-036-230 TXV 34800 16 13 CX35-50/60C EL296UH110XV48C 826830114ACX-036-230 TXV 35200 16 13 CX35-50/60C EL296UH110XV60C 826829414ACX-036-230 TXV 35200 16 13 CX35-50/60C SL280UH090V60C 826830814ACX-036-230 TXV 35200 16 13 CX35-50/60C SL280UH090XV60C 826830914ACX-036-230 TXV 35000 16 13 CX35-50/60C SL280UH110V60C 826831014ACX-036-230 TXV 35000 16 13 CX35-50/60C SL280UH110XV60C 826831114ACX-036-230 TXV 34800 16 13 CX35-50/60C SLP98UH090XV36C 8268298NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 117

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-036-230 TXV 34600 16 13 CX35-50/60C SLP98UH090XV48C 826830014ACX-036-230 TXV 35200 16 13 CX35-50/60C SLP98UH110XV60C 826829514ACX-036-230 TXV 34200 14.5 12.2 CX35-50/60C 826829314ACX-036-230 TXV 34200 14.25 12.2 CX38-38A 1054641214ACX-042-230 RFC 41500 14 12.2 C35-49C 847101914ACX-042-230 RFC 41000 14 12.2 C35-60D 847102114ACX-042-230 RFC 41500 14 12.2 CH33-43C 751307214ACX-042-230 RFC 42000 14 12.2 CH33-49 751121714ACX-042-230 RFC 41500 14 12.2 CH33-50/60C 751123914ACX-042-230 RFC 41500 14 12.2 CH35-51C 1051455314ACX-042-230 RFC 41000 14 12.2 CH35-60D 1051455414ACX-042-230 TXV 39500 14.5 12.2 C35-30/36B EL180UH090E48B 826769114ACX-042-230 TXV 39500 14.5 12.2 C35-30/36B EL180UH090XE48B 826769214ACX-042-230 TXV 39500 14.5 12.2 C35-30/36B SL280UH090V36B 826768814ACX-042-230 TXV 39500 14.5 12.2 C35-30/36B SL280UH090V48B 826768914ACX-042-230 TXV 39500 14.5 12.2 C35-30/36B SL280UH090XV48B 826769014ACX-042-230 TXV 39500 14.5 12.2 C35-30/36C EL180UH090E60C 826769314ACX-042-230 TXV 39000 14.5 12.2 C35-30/36C EL180UH110E60C 826769414ACX-042-230 TXV 39000 14.5 12.2 C35-30/36C EL180UH110XE60C 826769514ACX-042-230 TXV 39000 14.5 12.2 C35-30/36C EL195UH090XE48C 826769814ACX-042-230 TXV 39500 14.5 12.2 C35-30/36C EL195UH110XE60C 826770014ACX-042-230 TXV 39000 14.5 12.2 C35-30/36C EL296UH090XE48C 826769914ACX-042-230 TXV 39000 14.5 12.2 C35-30/36C EL296UH090XV36C 914375714ACX-042-230 TXV 39000 14.5 12.2 C35-30/36C EL296UH090XV48C 826770714ACX-042-230 TXV 39500 14.5 12.5 C35-30/36C EL296UH090XV60C 914375814ACX-042-230 TXV 39500 14.5 12.2 C35-30/36C EL296UH110XE60C 826770114ACX-042-230 TXV 39500 14.5 12.2 C35-30/36C EL296UH110XV60C 826770314ACX-042-230 TXV 39500 14.5 12.2 C35-30/36C SL280UH090V60C 826770414ACX-042-230 TXV 39500 14.5 12.2 C35-30/36C SL280UH090XV60C 826770514ACX-042-230 TXV 39500 14.5 12.2 C35-30/36C SL280UH110V60C 826769614ACX-042-230 TXV 39500 14.5 12.2 C35-30/36C SL280UH110XV60C 826769714ACX-042-230 TXV 39000 14.5 12.2 C35-30/36C SLP98UH090XV36C 914375914ACX-042-230 TXV 39000 14.5 12.2 C35-30/36C SLP98UH090XV48C 826770614ACX-042-230 TXV 39500 14.5 12.5 C35-30/36C SLP98UH090XV60C 914376014ACX-042-230 TXV 39500 14.5 12.2 C35-30/36C SLP98UH110XV60C 826770214ACX-042-230 TXV 41000 15.1 12.5 C35-36B EL180UH090E48B 826771014ACX-042-230 TXV 41000 15.1 12.5 C35-36B EL180UH090XE48B 826771114ACX-042-230 TXV 40500 14.5 12.2 C35-36B EL296UH045XV36B 826771214ACX-042-230 TXV 40500 14.5 12.2 C35-36B EL296UH070XV36B 826771414ACX-042-230 TXV 41000 15.1 12.5 C35-36B SL280UH090V36B 826771514ACX-042-230 TXV 41000 15.1 12.5 C35-36B SL280UH090V48B 826770814ACX-042-230 TXV 41000 15.1 12.5 C35-36B SL280UH090XV48B 826770914ACX-042-230 TXV 40500 14.5 12.2 C35-36B SLP98UH070XV36B 826771314ACX-042-230 TXV 41500 15.5 12.5 C35-48B EL180UH090E48B 826771714ACX-042-230 TXV 41500 15.5 12.5 C35-48B EL180UH090XE48B 826771814ACX-042-230 TXV 41000 14.5 12.2 C35-48B EL296UH045XV36B 826771914ACX-042-230 TXV 41000 14.5 12.2 C35-48B EL296UH070XV36B 826772114ACX-042-230 TXV 41000 15.1 12.5 C35-48B SL280UH090V36B 826772214ACX-042-230 TXV 41500 15.1 12.5 C35-48B SL280UH090V48B 8267723NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 118

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-042-230 TXV 41500 15.1 12.5 C35-48B SL280UH090XV48B 826771614ACX-042-230 TXV 41000 14.5 12.2 C35-48B SLP98UH070XV36B 826772014ACX-042-230 TXV 41500 15.5 12.5 C35-48C EL180UH090E60C 826773314ACX-042-230 TXV 41500 15.5 12.5 C35-48C EL180UH110E60C 826773414ACX-042-230 TXV 41500 15.5 12.5 C35-48C EL180UH110XE60C 826772414ACX-042-230 TXV 41000 15.5 12.5 C35-48C EL195UH090XE48C 826772514ACX-042-230 TXV 41500 15.5 12.5 C35-48C EL195UH110XE60C 826772714ACX-042-230 TXV 41000 15.5 12.5 C35-48C EL296UH090XE48C 826772614ACX-042-230 TXV 41000 15.1 12.5 C35-48C EL296UH090XV36C 826774214ACX-042-230 TXV 41000 15.1 12.5 C35-48C EL296UH090XV48C 826773514ACX-042-230 TXV 41500 15.1 12.5 C35-48C EL296UH090XV60C 826773814ACX-042-230 TXV 41500 15.5 12.5 C35-48C EL296UH110XE60C 826772814ACX-042-230 TXV 41500 15.1 12.5 C35-48C EL296UH110XV48C 826773614ACX-042-230 TXV 41500 15.5 12.5 C35-48C EL296UH110XV60C 826774014ACX-042-230 TXV 41500 15.5 12.5 C35-48C SL280UH090V60C 826772914ACX-042-230 TXV 41500 15.5 12.5 C35-48C SL280UH090XV60C 826773014ACX-042-230 TXV 41500 15.5 12.5 C35-48C SL280UH110V60C 826773114ACX-042-230 TXV 41500 15.5 12.5 C35-48C SL280UH110XV60C 826773214ACX-042-230 TXV 41000 15.1 12.5 C35-48C SLP98UH090XV36C 826774114ACX-042-230 TXV 41000 15.1 12.5 C35-48C SLP98UH090XV48C 826774314ACX-042-230 TXV 41500 15.1 12.5 C35-48C SLP98UH090XV60C 826773714ACX-042-230 TXV 41500 15.5 12.5 C35-48C SLP98UH110XV60C 826773914ACX-042-230 TXV 42000 16 13 C35-49C EL180UH090E60C 826776414ACX-042-230 TXV 42000 16 13 C35-49C EL180UH110E60C 826775814ACX-042-230 TXV 42000 16 13 C35-49C EL180UH110XE60C 826775914ACX-042-230 TXV 41500 15.5 12.5 C35-49C EL195UH090XE48C 826776014ACX-042-230 TXV 42000 15.5 12.5 C35-49C EL195UH110XE60C 826776114ACX-042-230 TXV 41500 15.5 12.5 C35-49C EL296UH090XE48C 826776214ACX-042-230 TXV 41500 15.5 12.5 C35-49C EL296UH090XV36C 826776314ACX-042-230 TXV 41500 15.5 12.5 C35-49C EL296UH090XV48C 826775214ACX-042-230 TXV 42000 15.5 12.5 C35-49C EL296UH090XV60C 826775314ACX-042-230 TXV 42000 15.5 12.5 C35-49C EL296UH110XE60C 826775414ACX-042-230 TXV 42000 15.5 12.5 C35-49C EL296UH110XV48C 826775514ACX-042-230 TXV 42000 15.5 12.5 C35-49C EL296UH110XV60C 826775614ACX-042-230 TXV 42000 16 13 C35-49C SL280UH090V60C 826775714ACX-042-230 TXV 42000 16 13 C35-49C SL280UH090XV60C 826774614ACX-042-230 TXV 42000 15.5 12.5 C35-49C SL280UH110V60C 826774714ACX-042-230 TXV 42000 15.5 12.5 C35-49C SL280UH110XV60C 826774814ACX-042-230 TXV 41500 15.5 12.5 C35-49C SLP98UH090XV36C 826774914ACX-042-230 TXV 41500 15.5 12.5 C35-49C SLP98UH090XV48C 826775014ACX-042-230 TXV 42000 15.5 12.5 C35-49C SLP98UH090XV60C 826775114ACX-042-230 TXV 42000 15.5 12.5 C35-49C SLP98UH110XV60C 826774514ACX-042-230 TXV 41500 14.25 12.2 C35-49C 826774414ACX-042-230 TXV 41000 15.5 12.5 C35-50/60C EL180UH090E60C 826778214ACX-042-230 TXV 41000 15.5 12.5 C35-50/60C EL180UH110E60C 826778314ACX-042-230 TXV 41000 15.5 12.5 C35-50/60C EL180UH110XE60C 826778414ACX-042-230 TXV 41000 15.1 12.5 C35-50/60C EL195UH090XE48C 826777614ACX-042-230 TXV 41000 15.1 12.5 C35-50/60C EL195UH110XE60C 826777714ACX-042-230 TXV 41000 15.1 12.5 C35-50/60C EL296UH090XE48C 8267778NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 119

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-042-230 TXV 41000 15.1 12.5 C35-50/60C EL296UH090XV36C 826777914ACX-042-230 TXV 41000 15.1 12.5 C35-50/60C EL296UH090XV48C 826778014ACX-042-230 TXV 41000 15.1 12.5 C35-50/60C EL296UH090XV60C 826778114ACX-042-230 TXV 41000 15.1 12.5 C35-50/60C EL296UH110XE60C 826777014ACX-042-230 TXV 41000 15.1 12.5 C35-50/60C EL296UH110XV48C 826777114ACX-042-230 TXV 41000 15.1 12.5 C35-50/60C EL296UH110XV60C 826777214ACX-042-230 TXV 41500 15.1 12.5 C35-50/60C SL280UH090V60C 826777314ACX-042-230 TXV 41500 15.1 12.5 C35-50/60C SL280UH090XV60C 826777414ACX-042-230 TXV 41000 15.1 12.5 C35-50/60C SL280UH110V60C 826777514ACX-042-230 TXV 41000 15.1 12.5 C35-50/60C SL280UH110XV60C 826776514ACX-042-230 TXV 41000 15.1 12.5 C35-50/60C SLP98UH090XV36C 826776614ACX-042-230 TXV 41000 15.1 12.5 C35-50/60C SLP98UH090XV48C 826776714ACX-042-230 TXV 41000 15.1 12.5 C35-50/60C SLP98UH090XV60C 826776814ACX-042-230 TXV 41000 15.1 12.5 C35-50/60C SLP98UH110XV60C 826776914ACX-042-230 TXV 40500 14.5 12.2 C35-50/60C 914376114ACX-042-230 TXV 42000 16 13 C35-60C EL180UH090E60C 826780314ACX-042-230 TXV 42000 16 13 C35-60C EL180UH110E60C 826780414ACX-042-230 TXV 42000 16 13 C35-60C EL180UH110XE60C 826780514ACX-042-230 TXV 42000 16 13 C35-60C EL195UH090XE48C 826779714ACX-042-230 TXV 42000 16 13 C35-60C EL195UH110XE60C 826779814ACX-042-230 TXV 42000 16 13 C35-60C EL296UH090XE48C 826779914ACX-042-230 TXV 42000 15.5 12.5 C35-60C EL296UH090XV36C 826780014ACX-042-230 TXV 42000 16 13 C35-60C EL296UH090XV48C 826780114ACX-042-230 TXV 42000 15.5 12.5 C35-60C EL296UH090XV60C 826780214ACX-042-230 TXV 42000 16 13 C35-60C EL296UH110XE60C 826779114ACX-042-230 TXV 42000 16 13 C35-60C EL296UH110XV48C 826779214ACX-042-230 TXV 42000 16 13 C35-60C EL296UH110XV60C 826779314ACX-042-230 TXV 42000 16 13 C35-60C SL280UH090V60C 826779414ACX-042-230 TXV 42000 16 13 C35-60C SL280UH090XV60C 826779514ACX-042-230 TXV 42000 16 13 C35-60C SL280UH110V60C 826779614ACX-042-230 TXV 42000 16 13 C35-60C SL280UH110XV60C 826778614ACX-042-230 TXV 42000 15.5 12.5 C35-60C SLP98UH090XV36C 826778714ACX-042-230 TXV 42000 16 13 C35-60C SLP98UH090XV48C 826778814ACX-042-230 TXV 42000 15.5 12.5 C35-60C SLP98UH090XV60C 826778914ACX-042-230 TXV 42000 16 13 C35-60C SLP98UH110XV60C 826779014ACX-042-230 TXV 42000 14.25 12.2 C35-60C 826778514ACX-042-230 TXV 42000 16 13 C35-60D EL180UH135E60D 826781014ACX-042-230 TXV 42000 15.5 12.5 C35-60D EL195UH135XE60D 826780714ACX-042-230 TXV 42000 15.5 12.5 C35-60D EL296UH135XE60D 826780814ACX-042-230 TXV 42000 16 13 C35-60D SL280UH135V60D 826780914ACX-042-230 TXV 41500 14.25 12.2 C35-60D 826780614ACX-042-230 TXV 41500 15.5 12.5 CBA27UHE-042 1025938014ACX-042-230 TXV 41500 15.5 12.5 CBA27UHE-048 1025938114ACX-042-230 TXV 41500 14 12.2 CBX25UH-042 751112014ACX-042-230 TXV 42000 14.5 12.5 CBX25UH-048 751112114ACX-042-230 TXV 42000 15.1 12.5 CBX25UHV-042 751112214ACX-042-230 TXV 42000 15.5 12.5 CBX25UHV-048 751112314ACX-042-230 TXV 41500 15.5 12.5 CBX27UH-042 751111814ACX-042-230 TXV 42000 15.1 12.5 CBX27UH-048 7511119NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 120

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-042-230 TXV 40500 14 12.2 CBX32M-042 751112414ACX-042-230 TXV 41500 14.25 12.2 CBX32M-048 751112514ACX-042-230 TXV 42000 15.1 12.5 CBX32MV-048 751112614ACX-042-230 TXV 42000 15 12.5 CBX40UHV-042 751112714ACX-042-230 TXV 42000 15 12.5 CBX40UHV-048 751112814ACX-042-230 TXV 40500 15.1 12.5 CH23-51 EL180UH090E60C 751112914ACX-042-230 TXV 40000 15.1 12.5 CH23-51 EL180UH110E60C 751113014ACX-042-230 TXV 40000 15.1 12.5 CH23-51 EL180UH110XE60C 751113114ACX-042-230 TXV 40000 15.1 12.5 CH23-51 EL296UH090XV48C 751113214ACX-042-230 TXV 40000 15.1 12.5 CH23-51 EL296UH090XV60C 751113314ACX-042-230 TXV 40000 15.1 12.5 CH23-51 EL296UH110XV48C 751113414ACX-042-230 TXV 40000 15.1 12.5 CH23-51 EL296UH110XV60C 751113514ACX-042-230 TXV 40500 15.1 12.5 CH23-51 SL280UH090V60C 751113614ACX-042-230 TXV 40000 15.1 12.5 CH23-51 SL280UH110V60C 751113714ACX-042-230 TXV 40000 15.1 12.5 CH23-51 SL280UH110XV60C 751113814ACX-042-230 TXV 40000 15.1 12.5 CH23-51 SLP98UH090XV48C 751113914ACX-042-230 TXV 40000 15.1 12.5 CH23-51 SLP98UH090XV60C 751114014ACX-042-230 TXV 40000 15.1 12.5 CH23-51 SLP98UH110XV60C 751114114ACX-042-230 TXV 40500 15.5 12.5 CH23-65 EL180UH090E60C 751114214ACX-042-230 TXV 40500 15.5 12.5 CH23-65 EL180UH110E60C 751114314ACX-042-230 TXV 40500 15.5 12.5 CH23-65 EL180UH110XE60C 751114414ACX-042-230 TXV 40500 15.1 12.5 CH23-65 EL296UH090XV48C 751114514ACX-042-230 TXV 40500 15.1 12.5 CH23-65 EL296UH090XV60C 751114614ACX-042-230 TXV 40500 15.1 12.5 CH23-65 EL296UH110XV48C 751114714ACX-042-230 TXV 40500 15.1 12.5 CH23-65 EL296UH110XV60C 751114814ACX-042-230 TXV 41000 15.5 12.5 CH23-65 SL280UH090V60C 751114914ACX-042-230 TXV 40500 15.5 12.5 CH23-65 SL280UH110V60C 751115014ACX-042-230 TXV 40500 15.5 12.5 CH23-65 SL280UH110XV60C 751115114ACX-042-230 TXV 40500 15.1 12.5 CH23-65 SLP98UH090XV48C 751115214ACX-042-230 TXV 40500 15.1 12.5 CH23-65 SLP98UH090XV60C 751115314ACX-042-230 TXV 40500 15.1 12.5 CH23-65 SLP98UH110XV60C 751115414ACX-042-230 TXV 40500 15.1 12.5 CH33-42 EL180UH090E48B 751115514ACX-042-230 TXV 40500 15.1 12.5 CH33-42 EL180UH090XE48B 751115614ACX-042-230 TXV 40500 15 12.5 CH33-42 SL280UH090V36B 751115814ACX-042-230 TXV 40500 15 12.5 CH33-42 SL280UH090V48B 751115914ACX-042-230 TXV 40500 15 12.5 CH33-42 SL280UH090XV48B 751116014ACX-042-230 TXV 42000 15.5 12.5 CH33-43B EL180UH090E48B 856594714ACX-042-230 TXV 42000 15.5 12.5 CH33-43B EL180UH090XE48B 856594814ACX-042-230 TXV 41500 15 12.5 CH33-43B EL296UH045XV36B 751116214ACX-042-230 TXV 41500 15 12.5 CH33-43B EL296UH070XV36B 751116414ACX-042-230 TXV 42000 15.5 12.5 CH33-43B SL280UH090V36B 751116514ACX-042-230 TXV 42000 15.5 12.5 CH33-43B SL280UH090V48B 751116614ACX-042-230 TXV 42000 15.5 12.5 CH33-43B SL280UH090XV48B 751116714ACX-042-230 TXV 41500 15 12.5 CH33-43B SLP98UH070XV36B 751116314ACX-042-230 TXV 41500 15.5 12.5 CH33-43C EL180UH090E60C 751117014ACX-042-230 TXV 41500 15.5 12.5 CH33-43C EL180UH110E60C 751117114ACX-042-230 TXV 41500 15.5 12.5 CH33-43C EL180UH110XE60C 751117214ACX-042-230 TXV 41000 15.5 12.5 CH33-43C EL195UH090XE48C 751117314ACX-042-230 TXV 41500 15.5 12.5 CH33-43C EL195UH110XE60C 7511174NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 121

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-042-230 TXV 41000 15.5 12.5 CH33-43C EL296UH090XE48C 751117514ACX-042-230 TXV 41500 15.5 12.5 CH33-43C EL296UH090XV36C 751117614ACX-042-230 TXV 41500 15.5 12.5 CH33-43C EL296UH090XV48C 751117714ACX-042-230 TXV 41500 15.5 12.5 CH33-43C EL296UH090XV60C 751117814ACX-042-230 TXV 41500 15.5 12.5 CH33-43C EL296UH110XE60C 751117914ACX-042-230 TXV 41500 15.5 12.5 CH33-43C EL296UH110XV48C 751118014ACX-042-230 TXV 41500 15.5 12.5 CH33-43C EL296UH110XV60C 751118114ACX-042-230 TXV 42000 16 13 CH33-43C SL280UH090V60C 751118214ACX-042-230 TXV 42000 16 13 CH33-43C SL280UH090XV60C 751118314ACX-042-230 TXV 41500 15.5 12.5 CH33-43C SL280UH110V60C 751118414ACX-042-230 TXV 41500 15.5 12.5 CH33-43C SL280UH110XV60C 751118514ACX-042-230 TXV 41500 15.5 12.5 CH33-43C SLP98UH090XV36C 751118614ACX-042-230 TXV 41500 15.5 12.5 CH33-43C SLP98UH090XV48C 751118714ACX-042-230 TXV 41500 15.5 12.5 CH33-43C SLP98UH090XV60C 751118814ACX-042-230 TXV 41500 15.5 12.5 CH33-43C SLP98UH110XV60C 751118914ACX-042-230 TXV 41500 14 12.2 CH33-43C 751116914ACX-042-230 TXV 41000 15.1 12.5 CH33-44/48B EL180UH090E48B 751119014ACX-042-230 TXV 41000 15.1 12.5 CH33-44/48B EL180UH090XE48B 751119114ACX-042-230 TXV 40500 14.5 12.2 CH33-44/48B EL296UH070XV36B 751119214ACX-042-230 TXV 41000 15.1 12.5 CH33-44/48B SL280UH090V36B 751119314ACX-042-230 TXV 41000 15.1 12.5 CH33-44/48B SL280UH090V48B 751119414ACX-042-230 TXV 41000 15.1 12.5 CH33-44/48B SL280UH090XV48B 751119514ACX-042-230 TXV 40500 14.5 12.2 CH33-44/48B SLP98UH070XV36B 915035114ACX-042-230 TXV 41000 15.5 12.5 CH33-48C EL180UH090E60C 751119714ACX-042-230 TXV 41000 15.5 12.5 CH33-48C EL180UH110E60C 751119814ACX-042-230 TXV 41000 15.5 12.5 CH33-48C EL180UH110XE60C 751119914ACX-042-230 TXV 41000 15.1 12.5 CH33-48C EL195UH090XE48C 751120014ACX-042-230 TXV 41500 15.1 12.5 CH33-48C EL195UH110XE60C 751120114ACX-042-230 TXV 41000 15.1 12.5 CH33-48C EL296UH090XE48C 751120214ACX-042-230 TXV 41000 15.1 12.5 CH33-48C EL296UH090XV36C 751120314ACX-042-230 TXV 41000 15.1 12.5 CH33-48C EL296UH090XV48C 751120414ACX-042-230 TXV 41500 15.1 12.5 CH33-48C EL296UH090XV60C 751120514ACX-042-230 TXV 41500 15.1 12.5 CH33-48C EL296UH110XE60C 751120614ACX-042-230 TXV 41000 15.1 12.5 CH33-48C EL296UH110XV48C 751120714ACX-042-230 TXV 41000 15.1 12.5 CH33-48C EL296UH110XV60C 751120814ACX-042-230 TXV 41500 15.5 12.5 CH33-48C SL280UH090V60C 751120914ACX-042-230 TXV 41500 15.5 12.5 CH33-48C SL280UH090XV60C 751121014ACX-042-230 TXV 41000 15.1 12.5 CH33-48C SL280UH110V60C 751121114ACX-042-230 TXV 41000 15.1 12.5 CH33-48C SL280UH110XV60C 751121214ACX-042-230 TXV 41000 15.1 12.5 CH33-48C SLP98UH090XV36C 751121314ACX-042-230 TXV 41000 15.1 12.5 CH33-48C SLP98UH090XV48C 751121414ACX-042-230 TXV 41500 15.1 12.5 CH33-48C SLP98UH090XV60C 751121514ACX-042-230 TXV 41000 15.1 12.5 CH33-48C SLP98UH110XV60C 751121614ACX-042-230 TXV 42000 15.5 12.5 CH33-49 EL180UH090E60C 751121914ACX-042-230 TXV 42000 15.5 12.5 CH33-49 EL180UH110E60C 751122014ACX-042-230 TXV 42000 15.5 12.5 CH33-49 EL180UH110XE60C 751122114ACX-042-230 TXV 41500 15.5 12.5 CH33-49 EL195UH090XE48C 751122214ACX-042-230 TXV 42000 15.5 12.5 CH33-49 EL195UH110XE60C 751122314ACX-042-230 TXV 41500 15.5 12.5 CH33-49 EL296UH090XE48C 7511224NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 122

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-042-230 TXV 41500 15.5 12.5 CH33-49 EL296UH090XV36C 751122514ACX-042-230 TXV 42000 15.5 12.5 CH33-49 EL296UH090XV48C 751122614ACX-042-230 TXV 42000 15.5 12.5 CH33-49 EL296UH090XV60C 751122714ACX-042-230 TXV 42000 15.5 12.5 CH33-49 EL296UH110XE60C 751122814ACX-042-230 TXV 42000 15.5 12.5 CH33-49 EL296UH110XV48C 751122914ACX-042-230 TXV 42000 15.5 12.5 CH33-49 EL296UH110XV60C 751123014ACX-042-230 TXV 42000 15.5 12.5 CH33-49 SL280UH090V60C 751123114ACX-042-230 TXV 42000 15.5 12.5 CH33-49 SL280UH090XV60C 751123214ACX-042-230 TXV 42000 15.5 12.5 CH33-49 SL280UH110V60C 751123314ACX-042-230 TXV 42000 15.5 12.5 CH33-49 SL280UH110XV60C 751123414ACX-042-230 TXV 41500 15.5 12.5 CH33-49 SLP98UH090XV36C 751123514ACX-042-230 TXV 42000 15.5 12.5 CH33-49 SLP98UH090XV48C 751123614ACX-042-230 TXV 42000 15.5 12.5 CH33-49 SLP98UH090XV60C 751123714ACX-042-230 TXV 42000 15.5 12.5 CH33-49 SLP98UH110XV60C 751123814ACX-042-230 TXV 42000 14 12.2 CH33-49 751121814ACX-042-230 TXV 41500 15.5 12.5 CH33-50/60C EL180UH090E60C 751124114ACX-042-230 TXV 41500 15.5 12.5 CH33-50/60C EL180UH110E60C 751124214ACX-042-230 TXV 41500 15.5 12.5 CH33-50/60C EL180UH110XE60C 751124314ACX-042-230 TXV 41500 15.5 12.5 CH33-50/60C EL195UH090XE48C 751124414ACX-042-230 TXV 42000 15.5 12.5 CH33-50/60C EL195UH110XE60C 751124514ACX-042-230 TXV 41500 15.5 12.5 CH33-50/60C EL296UH090XE48C 751124614ACX-042-230 TXV 41500 15.1 12.5 CH33-50/60C EL296UH090XV36C 751124714ACX-042-230 TXV 41500 15.5 12.5 CH33-50/60C EL296UH090XV48C 751124814ACX-042-230 TXV 42000 15.1 12.5 CH33-50/60C EL296UH090XV60C 751124914ACX-042-230 TXV 42000 15.5 12.5 CH33-50/60C EL296UH110XE60C 751125014ACX-042-230 TXV 41500 15.5 12.5 CH33-50/60C EL296UH110XV48C 751125114ACX-042-230 TXV 41500 15.5 12.5 CH33-50/60C EL296UH110XV60C 751125214ACX-042-230 TXV 42000 15.5 12.5 CH33-50/60C SL280UH090V60C 751125314ACX-042-230 TXV 42000 15.5 12.5 CH33-50/60C SL280UH090XV60C 751125414ACX-042-230 TXV 41500 15.5 12.5 CH33-50/60C SL280UH110V60C 751125514ACX-042-230 TXV 41500 15.5 12.5 CH33-50/60C SL280UH110XV60C 751125614ACX-042-230 TXV 41500 15.1 12.5 CH33-50/60C SLP98UH090XV36C 751125714ACX-042-230 TXV 41500 15.5 12.5 CH33-50/60C SLP98UH090XV48C 751125814ACX-042-230 TXV 42000 15.1 12.5 CH33-50/60C SLP98UH090XV60C 751125914ACX-042-230 TXV 41500 15.5 12.5 CH33-50/60C SLP98UH110XV60C 751126014ACX-042-230 TXV 41500 14 12.2 CH33-50/60C 751124014ACX-042-230 TXV 42000 15.5 12.5 CH35-42B EL180UH090E48B 751126114ACX-042-230 TXV 42000 15.5 12.5 CH35-42B EL180UH090XE48B 751126214ACX-042-230 TXV 42000 15.1 12.5 CH35-42B EL296UH045XV36B 751126314ACX-042-230 TXV 41500 15 12.5 CH35-42B EL296UH070XV36B 751126414ACX-042-230 TXV 42000 15.5 12.5 CH35-42B SL280UH090V36B 751126514ACX-042-230 TXV 42000 15.5 12.5 CH35-42B SL280UH090V48B 751126614ACX-042-230 TXV 42000 15.5 12.5 CH35-42B SL280UH090XV48B 751126714ACX-042-230 TXV 41500 15 12.5 CH35-42B SLP98UH070XV36B 751126814ACX-042-230 TXV 41500 15.5 12.5 CH35-42C EL180UH090E60C 751127014ACX-042-230 TXV 41500 15.5 12.5 CH35-42C EL180UH110E60C 751127114ACX-042-230 TXV 41500 15.5 12.5 CH35-42C EL180UH110XE60C 751127214ACX-042-230 TXV 41500 15.5 12.5 CH35-42C EL195UH090XE48C 751127314ACX-042-230 TXV 42000 15.5 12.5 CH35-42C EL195UH110XE60C 7511274NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 123

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-042-230 TXV 41500 15.5 12.5 CH35-42C EL296UH090XE48C 751127514ACX-042-230 TXV 41500 15.5 12.5 CH35-42C EL296UH090XV36C 751127614ACX-042-230 TXV 41500 15.5 12.5 CH35-42C EL296UH090XV48C 751127714ACX-042-230 TXV 42000 15.5 12.5 CH35-42C EL296UH090XV60C 751127814ACX-042-230 TXV 42000 15.5 12.5 CH35-42C EL296UH110XE60C 751127914ACX-042-230 TXV 41500 15.5 12.5 CH35-42C EL296UH110XV48C 751128014ACX-042-230 TXV 41500 15.5 12.5 CH35-42C EL296UH110XV60C 751128114ACX-042-230 TXV 42000 16 13 CH35-42C SL280UH090V60C 751128214ACX-042-230 TXV 42000 16 13 CH35-42C SL280UH090XV60C 751128314ACX-042-230 TXV 41500 15.5 12.5 CH35-42C SL280UH110V60C 751128414ACX-042-230 TXV 41500 15.5 12.5 CH35-42C SL280UH110XV60C 751128514ACX-042-230 TXV 41500 15.5 12.5 CH35-42C SLP98UH090XV36C 751128614ACX-042-230 TXV 41500 15.5 12.5 CH35-42C SLP98UH090XV48C 751128714ACX-042-230 TXV 42000 15.5 12.5 CH35-42C SLP98UH090XV60C 751128814ACX-042-230 TXV 41500 15.5 12.5 CH35-42C SLP98UH110XV60C 751128914ACX-042-230 TXV 41500 14 12.2 CH35-42C 751126914ACX-042-230 TXV 41500 15.5 12.5 CH35-48B EL180UH090E48B 751129014ACX-042-230 TXV 41500 15.5 12.5 CH35-48B EL180UH090XE48B 751129114ACX-042-230 TXV 41000 14.5 12.2 CH35-48B EL296UH045XV36B 751129214ACX-042-230 TXV 41000 14.5 12.2 CH35-48B EL296UH070XV36B 751129314ACX-042-230 TXV 41500 15.1 12.5 CH35-48B SL280UH090V36B 751129414ACX-042-230 TXV 41500 15.1 12.5 CH35-48B SL280UH090V48B 751129514ACX-042-230 TXV 41500 15.1 12.5 CH35-48B SL280UH090XV48B 751129614ACX-042-230 TXV 41000 14.5 12.2 CH35-48B SLP98UH070XV36B 751129714ACX-042-230 TXV 41500 15.5 12.5 CH35-48C EL180UH090E60C 751129914ACX-042-230 TXV 41500 15.5 12.5 CH35-48C EL180UH110E60C 751130014ACX-042-230 TXV 41500 15.5 12.5 CH35-48C EL180UH110XE60C 751130114ACX-042-230 TXV 41000 15.1 12.5 CH35-48C EL195UH090XE48C 751130214ACX-042-230 TXV 41500 15.1 12.5 CH35-48C EL195UH110XE60C 751130314ACX-042-230 TXV 41000 15.1 12.5 CH35-48C EL296UH090XE48C 751130414ACX-042-230 TXV 41000 15.1 12.5 CH35-48C EL296UH090XV36C 751130514ACX-042-230 TXV 41500 15.1 12.5 CH35-48C EL296UH090XV48C 751130614ACX-042-230 TXV 41500 15.1 12.5 CH35-48C EL296UH090XV60C 751130714ACX-042-230 TXV 41500 15.1 12.5 CH35-48C EL296UH110XE60C 751130814ACX-042-230 TXV 41500 15.5 12.5 CH35-48C EL296UH110XV48C 751130914ACX-042-230 TXV 41500 15.1 12.5 CH35-48C EL296UH110XV60C 751131014ACX-042-230 TXV 41500 15.5 12.5 CH35-48C SL280UH090V60C 751131114ACX-042-230 TXV 41500 15.5 12.5 CH35-48C SL280UH090XV60C 751131214ACX-042-230 TXV 41500 15.1 12.5 CH35-48C SL280UH110V60C 751131314ACX-042-230 TXV 41500 15.1 12.5 CH35-48C SL280UH110XV60C 751131414ACX-042-230 TXV 41000 15.1 12.5 CH35-48C SLP98UH090XV36C 751131514ACX-042-230 TXV 41500 15.1 12.5 CH35-48C SLP98UH090XV48C 751131614ACX-042-230 TXV 41500 15.1 12.5 CH35-48C SLP98UH090XV60C 751131714ACX-042-230 TXV 41500 15.1 12.5 CH35-48C SLP98UH110XV60C 751131814ACX-042-230 TXV 41500 14 12.2 CH35-48C 751129814ACX-042-230 TXV 42000 15.5 12.5 CH35-51C EL180UH090E48B 1004043114ACX-042-230 TXV 42000 15.5 12.5 CH35-51C EL180UH090E60C 751132014ACX-042-230 TXV 42000 15.5 12.5 CH35-51C EL180UH110E60C 751132114ACX-042-230 TXV 42000 15.5 12.5 CH35-51C EL180UH110XE60C 7511322NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 124

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-042-230 TXV 41500 15.5 12.5 CH35-51C EL195UH090XE48C 751132314ACX-042-230 TXV 42000 15.5 12.5 CH35-51C EL195UH110XE60C 751132414ACX-042-230 TXV 41500 15.5 12.5 CH35-51C EL296UH090XE48C 751132514ACX-042-230 TXV 41500 15.5 12.5 CH35-51C EL296UH090XV36C 751132614ACX-042-230 TXV 42000 15.5 12.5 CH35-51C EL296UH090XV48C 751132714ACX-042-230 TXV 42000 15.5 12.5 CH35-51C EL296UH090XV60C 751132814ACX-042-230 TXV 42000 15.5 12.5 CH35-51C EL296UH110XE60C 751132914ACX-042-230 TXV 42000 15.5 12.5 CH35-51C EL296UH110XV48C 751133014ACX-042-230 TXV 42000 15.5 12.5 CH35-51C EL296UH110XV60C 751133114ACX-042-230 TXV 42000 15.5 12.5 CH35-51C SL280UH090V60C 751133214ACX-042-230 TXV 42000 15.5 12.5 CH35-51C SL280UH090XV60C 751133314ACX-042-230 TXV 42000 15.5 12.5 CH35-51C SL280UH110V60C 751133414ACX-042-230 TXV 42000 15.5 12.5 CH35-51C SL280UH110XV60C 751133514ACX-042-230 TXV 41500 15.5 12.5 CH35-51C SLP98UH090XV36C 751133614ACX-042-230 TXV 42000 15.5 12.5 CH35-51C SLP98UH090XV48C 751133714ACX-042-230 TXV 42000 15.5 12.5 CH35-51C SLP98UH090XV60C 751133814ACX-042-230 TXV 42000 15.5 12.5 CH35-51C SLP98UH110XV60C 751133914ACX-042-230 TXV 42000 14 12.2 CH35-51C 751131914ACX-042-230 TXV 40500 15.1 12.5 CR33-48 EL180DF110E60C 751134114ACX-042-230 TXV 40500 15.1 12.5 CR33-48 EL195DF090XE48C 751134214ACX-042-230 TXV 40500 15.1 12.5 CR33-48 EL195DF110XE60C 751134314ACX-042-230 TXV 40500 15.1 12.5 CR33-48 EL296DF090XE48C 751134414ACX-042-230 TXV 40500 15 12.2 CR33-48 EL296DF090XV60C 751134514ACX-042-230 TXV 40500 15.1 12.5 CR33-48 EL296DF110XE60C 751134614ACX-042-230 TXV 40500 14.5 12.2 CR33-48 SL280DF090V48B 751134014ACX-042-230 TXV 40500 15.1 12.5 CR33-48 SL280DF090V60C 751134714ACX-042-230 TXV 40500 15.1 12.5 CR33-48 SL280DF110V60C 751134814ACX-042-230 TXV 40500 15.1 12.5 CR33-48 SLP98DF090XV36C 914376214ACX-042-230 TXV 40500 15 12.2 CR33-48 SLP98DF090XV60C 751135014ACX-042-230 TXV 41500 15.5 12.5 CR33-50/60 EL180DF110E60C 751135114ACX-042-230 TXV 41000 15.1 12.5 CR33-50/60 EL195DF090XE48C 751135214ACX-042-230 TXV 41500 15.5 12.5 CR33-50/60 EL195DF110XE60C 751135314ACX-042-230 TXV 41000 15.1 12.5 CR33-50/60 EL296DF090XE48C 751135414ACX-042-230 TXV 41500 15.1 12.5 CR33-50/60 EL296DF090XV60C 751135514ACX-042-230 TXV 41500 15.5 12.5 CR33-50/60 EL296DF110XE60C 751135614ACX-042-230 TXV 41500 15.5 12.5 CR33-50/60 EL296DF110XV60C 751135714ACX-042-230 TXV 41000 15.5 12.5 CR33-50/60 SL280DF090V60C 751135814ACX-042-230 TXV 41500 15.5 12.5 CR33-50/60 SL280DF110V60C 751135914ACX-042-230 TXV 41000 15.1 12.5 CR33-50/60 SLP98DF090XV36C 751136014ACX-042-230 TXV 41000 15.1 12.5 CR33-50/60 SLP98DF090XV48C 751136114ACX-042-230 TXV 41500 15.1 12.5 CR33-50/60 SLP98DF090XV60C 751136214ACX-042-230 TXV 41500 15.5 12.5 CR33-50/60 SLP98DF110XV60C 751136314ACX-042-230 TXV 39500 14.5 12.2 CX35-30/36B EL180UH090E48B 826781114ACX-042-230 TXV 39500 14.5 12.2 CX35-30/36B EL180UH090XE48B 826781214ACX-042-230 TXV 39500 14.5 12.2 CX35-30/36B SL280UH090V36B 826781314ACX-042-230 TXV 39500 14.5 12.2 CX35-30/36B SL280UH090V48B 826781414ACX-042-230 TXV 39500 14.5 12.2 CX35-30/36B SL280UH090XV48B 826781514ACX-042-230 TXV 39500 14.5 12.2 CX35-30/36C EL180UH090E60C 826782814ACX-042-230 TXV 39000 14.5 12.2 CX35-30/36C EL180UH110E60C 8267829NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 125

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-042-230 TXV 39000 14.5 12.2 CX35-30/36C EL180UH110XE60C 826783014ACX-042-230 TXV 39000 14.5 12.2 CX35-30/36C EL195UH090XE48C 826782414ACX-042-230 TXV 39500 14.5 12.2 CX35-30/36C EL195UH110XE60C 826782514ACX-042-230 TXV 39000 14.5 12.2 CX35-30/36C EL296UH090XE48C 826782614ACX-042-230 TXV 39000 14.5 12.2 CX35-30/36C EL296UH090XV36C 914376314ACX-042-230 TXV 39000 14.5 12.2 CX35-30/36C EL296UH090XV48C 826782714ACX-042-230 TXV 39500 14.5 12.5 CX35-30/36C EL296UH090XV60C 914376414ACX-042-230 TXV 39500 14.5 12.2 CX35-30/36C EL296UH110XE60C 826781814ACX-042-230 TXV 39500 14.5 12.2 CX35-30/36C EL296UH110XV60C 826781914ACX-042-230 TXV 39500 14.5 12.2 CX35-30/36C SL280UH090V60C 826782014ACX-042-230 TXV 39500 14.5 12.2 CX35-30/36C SL280UH090XV60C 826782114ACX-042-230 TXV 39500 14.5 12.2 CX35-30/36C SL280UH110V60C 826782214ACX-042-230 TXV 39500 14.5 12.2 CX35-30/36C SL280UH110XV60C 826782314ACX-042-230 TXV 39000 14.5 12.2 CX35-30/36C SLP98UH090XV36C 914376514ACX-042-230 TXV 39000 14.5 12.2 CX35-30/36C SLP98UH090XV48C 826781614ACX-042-230 TXV 39500 14.5 12.5 CX35-30/36C SLP98UH090XV60C 914376614ACX-042-230 TXV 39500 14.5 12.2 CX35-30/36C SLP98UH110XV60C 826781714ACX-042-230 TXV 41000 15.1 12.5 CX35-36B EL180UH090E48B 826783714ACX-042-230 TXV 41000 15.1 12.5 CX35-36B EL180UH090XE48B 826783814ACX-042-230 TXV 40500 14.5 12.2 CX35-36B EL296UH045XV36B 826783114ACX-042-230 TXV 40500 14.5 12.2 CX35-36B EL296UH070XV36B 826783214ACX-042-230 TXV 41000 15.1 12.5 CX35-36B SL280UH090V36B 826783314ACX-042-230 TXV 41000 15.1 12.5 CX35-36B SL280UH090V48B 826783414ACX-042-230 TXV 41000 15.1 12.5 CX35-36B SL280UH090XV48B 826783514ACX-042-230 TXV 40500 14.5 12.2 CX35-36B SLP98UH070XV36B 826783614ACX-042-230 TXV 41000 14.5 12.2 CX35-36B 914376714ACX-042-230 TXV 41500 15.5 12.5 CX35-48B EL180UH090E48B 826784314ACX-042-230 TXV 41500 15.5 12.5 CX35-48B EL180UH090XE48B 826784414ACX-042-230 TXV 41000 14.5 12.2 CX35-48B EL296UH045XV36B 826784514ACX-042-230 TXV 41000 14.5 12.2 CX35-48B EL296UH070XV36B 826784614ACX-042-230 TXV 41000 15.1 12.5 CX35-48B SL280UH090V36B 826783914ACX-042-230 TXV 41500 15.1 12.5 CX35-48B SL280UH090V48B 826784014ACX-042-230 TXV 41500 15.1 12.5 CX35-48B SL280UH090XV48B 826784114ACX-042-230 TXV 41000 14.5 12.2 CX35-48B SLP98UH070XV36B 826784214ACX-042-230 TXV 41000 14.5 12.2 CX35-48B 914376814ACX-042-230 TXV 41500 15.5 12.5 CX35-48C EL180UH090E60C 826786514ACX-042-230 TXV 41500 15.5 12.5 CX35-48C EL180UH110E60C 826786614ACX-042-230 TXV 41500 15.5 12.5 CX35-48C EL180UH110XE60C 826785914ACX-042-230 TXV 41000 15.5 12.5 CX35-48C EL195UH090XE48C 826786014ACX-042-230 TXV 41500 15.5 12.5 CX35-48C EL195UH110XE60C 826786114ACX-042-230 TXV 41000 15.5 12.5 CX35-48C EL296UH090XE48C 826786214ACX-042-230 TXV 41000 15.1 12.5 CX35-48C EL296UH090XV36C 826786314ACX-042-230 TXV 41000 15.1 12.5 CX35-48C EL296UH090XV48C 826786414ACX-042-230 TXV 41500 15.1 12.5 CX35-48C EL296UH090XV60C 826785314ACX-042-230 TXV 41500 15.5 12.5 CX35-48C EL296UH110XE60C 826785414ACX-042-230 TXV 41500 15.1 12.5 CX35-48C EL296UH110XV48C 826785514ACX-042-230 TXV 41500 15.5 12.5 CX35-48C EL296UH110XV60C 826785614ACX-042-230 TXV 41500 15.5 12.5 CX35-48C SL280UH090V60C 826785714ACX-042-230 TXV 41500 15.5 12.5 CX35-48C SL280UH090XV60C 8267858NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 126

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-042-230 TXV 41500 15.5 12.5 CX35-48C SL280UH110V60C 826784714ACX-042-230 TXV 41500 15.5 12.5 CX35-48C SL280UH110XV60C 826784814ACX-042-230 TXV 41000 15.1 12.5 CX35-48C SLP98UH090XV36C 826784914ACX-042-230 TXV 41000 15.1 12.5 CX35-48C SLP98UH090XV48C 826785014ACX-042-230 TXV 41500 15.1 12.5 CX35-48C SLP98UH090XV60C 826785114ACX-042-230 TXV 41500 15.5 12.5 CX35-48C SLP98UH110XV60C 826785214ACX-042-230 TXV 41000 14.5 12.2 CX35-48C 914376914ACX-042-230 TXV 42000 16 13 CX35-49C EL180UH090E60C 826788614ACX-042-230 TXV 42000 16 13 CX35-49C EL180UH110E60C 826788714ACX-042-230 TXV 42000 16 13 CX35-49C EL180UH110XE60C 826788014ACX-042-230 TXV 41500 15.5 12.5 CX35-49C EL195UH090XE48C 826788114ACX-042-230 TXV 42000 15.5 12.5 CX35-49C EL195UH110XE60C 826788214ACX-042-230 TXV 41500 15.5 12.5 CX35-49C EL296UH090XE48C 826788314ACX-042-230 TXV 41500 15.5 12.5 CX35-49C EL296UH090XV36C 826788414ACX-042-230 TXV 41500 15.5 12.5 CX35-49C EL296UH090XV48C 826788514ACX-042-230 TXV 42000 15.5 12.5 CX35-49C EL296UH090XV60C 826787414ACX-042-230 TXV 42000 15.5 12.5 CX35-49C EL296UH110XE60C 826787514ACX-042-230 TXV 42000 15.5 12.5 CX35-49C EL296UH110XV48C 826787614ACX-042-230 TXV 42000 15.5 12.5 CX35-49C EL296UH110XV60C 826787714ACX-042-230 TXV 42000 16 13 CX35-49C SL280UH090V60C 826787814ACX-042-230 TXV 42000 16 13 CX35-49C SL280UH090XV60C 826787914ACX-042-230 TXV 42000 15.5 12.5 CX35-49C SL280UH110V60C 826786814ACX-042-230 TXV 42000 15.5 12.5 CX35-49C SL280UH110XV60C 826786914ACX-042-230 TXV 41500 15.5 12.5 CX35-49C SLP98UH090XV36C 826787014ACX-042-230 TXV 41500 15.5 12.5 CX35-49C SLP98UH090XV48C 826787114ACX-042-230 TXV 42000 15.5 12.5 CX35-49C SLP98UH090XV60C 826787214ACX-042-230 TXV 42000 15.5 12.5 CX35-49C SLP98UH110XV60C 826787314ACX-042-230 TXV 41500 14.25 12.2 CX35-49C 826786714ACX-042-230 TXV 41000 15 12.5 CX35-50/60C EL180UH090E48B 1004043014ACX-042-230 TXV 41000 15.5 12.5 CX35-50/60C EL180UH090E60C 826790214ACX-042-230 TXV 41000 15.5 12.5 CX35-50/60C EL180UH110E60C 826790314ACX-042-230 TXV 41000 15.5 12.5 CX35-50/60C EL180UH110XE60C 826790414ACX-042-230 TXV 41000 15.1 12.5 CX35-50/60C EL195UH090XE48C 826790514ACX-042-230 TXV 41000 15.1 12.5 CX35-50/60C EL195UH110XE60C 826790614ACX-042-230 TXV 41000 15.1 12.5 CX35-50/60C EL296UH090XE48C 826790714ACX-042-230 TXV 41000 15.1 12.5 CX35-50/60C EL296UH090XV36C 826789614ACX-042-230 TXV 41000 15.1 12.5 CX35-50/60C EL296UH090XV48C 826789714ACX-042-230 TXV 41000 15.1 12.5 CX35-50/60C EL296UH090XV60C 826789814ACX-042-230 TXV 41000 15.1 12.5 CX35-50/60C EL296UH110XE60C 826789914ACX-042-230 TXV 41000 15.1 12.5 CX35-50/60C EL296UH110XV48C 826790014ACX-042-230 TXV 41000 15.1 12.5 CX35-50/60C EL296UH110XV60C 826790114ACX-042-230 TXV 41500 15.1 12.5 CX35-50/60C SL280UH090V60C 826789014ACX-042-230 TXV 41500 15.1 12.5 CX35-50/60C SL280UH090XV60C 826789114ACX-042-230 TXV 41000 15.1 12.5 CX35-50/60C SL280UH110V60C 826789214ACX-042-230 TXV 41000 15.1 12.5 CX35-50/60C SL280UH110XV60C 826789314ACX-042-230 TXV 41000 15.1 12.5 CX35-50/60C SLP98UH090XV36C 826789414ACX-042-230 TXV 41000 15.1 12.5 CX35-50/60C SLP98UH090XV48C 826789514ACX-042-230 TXV 41000 15.1 12.5 CX35-50/60C SLP98UH090XV60C 826788814ACX-042-230 TXV 41000 15.1 12.5 CX35-50/60C SLP98UH110XV60C 8267889NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

14ACX - 1.5 to 5 Ton Air Conditioner / Page 127

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

14ACX-042-230 TXV 40500 14.5 12.2 CX35-50/60C 914377014ACX-042-230 TXV 42000 16 13 CX35-60C EL180UH090E60C 826792114ACX-042-230 TXV 42000 16 13 CX35-60C EL180UH110E60C 826792214ACX-042-230 TXV 42000 16 13 CX35-60C EL180UH110XE60C 826792314ACX-042-230 TXV 42000 16 13 CX35-60C EL195UH090XE48C 826792414ACX-042-230 TXV 42000 16 13 CX35-60C EL195UH110XE60C 826792514ACX-042-230 TXV 42000 16 13 CX35-60C EL296UH090XE48C 826792614ACX-042-230 TXV 42000 15.5 12.5 CX35-60C EL296UH090XV36C 826791514ACX-042-230 TXV 42000 16 13 CX35-60C EL296UH090XV48C 826791614ACX-042-230 TXV 42000 15.5 12.5 CX35-60C EL296UH090XV60C 826791714ACX-042-230 TXV 42000 16 13 CX35-60C EL296UH110XE60C 826791814ACX-042-230 TXV 42000 16 13 CX35-60C EL296UH110XV60C 826791914ACX-042-230 TXV 42000 16 13 CX35-60C SL280UH090V60C 826792014ACX-042-230 TXV 42000 16 13 CX35-60C SL280UH090XV60C 826790914ACX-042-230 TXV 42000 16 13 CX35-60C SL280UH110V60C 826791014ACX-042-230 TXV 42000 16 13 CX35-60C SL280UH110XV60C 826791114ACX-042-230 TXV 42000 15.5 12.5 CX35-60C SLP98UH090XV36C 826791214ACX-042-230 TXV 42000 16 13 CX35-60C SLP98UH090XV48C 826791314ACX-042-230 TXV 42000 15.5 12.5 CX35-60C SLP98UH090XV60C 826791414ACX-042-230 TXV 42000 16 13 CX35-60C SLP98UH110XV60C 826790814ACX-042-230 TXV 42000 15.1 12.5 CX35-60C 914377114ACX-042-230 TXV 42000 16 13 CX35-60D EL180UH135E60D 826792814ACX-042-230 TXV 42000 15.5 12.5 CX35-60D EL195UH135XE60D 826792914ACX-042-230 TXV 42000 15.5 12.5 CX35-60D EL296UH135XE60D 826793014ACX-042-230 TXV 42000 16 13 CX35-60D SL280UH135V60D 826793114ACX-042-230 TXV 41500 14.5 12.2 CX35-60D 826792714ACX-042-230 TXV 41500 14.25 12.2 CX38-49C 10546731NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

NOTE - Due to Lennox’ ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2017 Lennox Industries, Inc.

Visit us at www.lennox.com

For the latest technical information, www.LennoxPROs.com

Contact us at 1-800-4-LENNOX

REVISIONS

REVISIONS

Sections Description of Change

AHRI System Matches Updated