10/8/2008 Motorola confidentialVersion:00
2
MDB for Ultra & Metro sitesMDB for Ultra & Metro sites
ApprovedApprovedNot ApprovedNot Approved
Yellow polyester labels not allowed for MDB labelingCircuit Breakers brand is not approvedWrong diameter of yellow-green earth cable used
PVC Plate with engraved text labels for MDB cover and CBsshould be used, All outgoing/incoming cables should belabeled, Main SLD should be attached on MDBs doorABB Circuit breakers should be used4~5mm yellow-green earth cable should be used to connect
MDB door to earth system
8/6/2019 1.4.3 - Quality Manual for IBS DU
3/34
10/8/2008 Motorola confidentialVersion:00
3
Power SocketsPower Sockets
ApprovedApprovedNot ApprovedNot Approved
Labels should be the same sizeand conform with the standards
PVC Plate with engraved text labelsshould be used
8/6/2019 1.4.3 - Quality Manual for IBS DU
4/34
10/8/2008 Motorola confidentialVersion:00
4
Earth Cable LabelingEarth Cable Labeling
ApprovedApprovedNot ApprovedNot Approved
Yellow Green electrical tape not allowed attermination pointsLabels not conform with the standards
Use heated shrinks at all termination points(the heated shrink should be cover the joint of Earthingcable with its cable shoe)Use black label tags-Nylon- UV resistant with Yellow
Alpha- numerics - Nylon- UV resistant
8/6/2019 1.4.3 - Quality Manual for IBS DU
5/34
10/8/2008 Motorola confidentialVersion:00
5
Standard Earth Cable LabelingStandard Earth Cable Labeling
8/6/2019 1.4.3 - Quality Manual for IBS DU
6/34
10/8/2008 Motorola confidentialVersion:00
6
PVCPVC --Trunking InstallationTrunking Installation
ApprovedApprovedNot ApprovedNot Approved
Different kinds of PVC Trunking with bad quality are usedWhite 75x75 mm PVC Trunking to be installedwith good finishing for all joints
8/6/2019 1.4.3 - Quality Manual for IBS DU
7/34
10/8/2008 Motorola confidentialVersion:00
7
PVCPVC --Trunking InstallationTrunking Installation
ApprovedApprovedNot ApprovedNot Approved
Bad finishing for the joint Good finishing for the joint
8/6/2019 1.4.3 - Quality Manual for IBS DU
8/34
10/8/2008 Motorola confidentialVersion:00
8
MetalMetal --Trunking InstallationTrunking Installation
Metal Trunking to be installed depend on site specifications and it shouldbe 75x75mm with good finishing for all jointsNote:-
In this case all joints should be connected by grounding cable as shownabove
8/6/2019 1.4.3 - Quality Manual for IBS DU
9/34
10/8/2008 Motorola confidentialVersion:00
9
Right Angle Connector InstallationRight Angle Connector Installation
Not ApprovedNot Approved ApprovedApproved
The feeder cables are not inside the cable tray and notprotected, their disposition is unacceptable Proper installation using the right angle connectors
8/6/2019 1.4.3 - Quality Manual for IBS DU
10/34
10/8/2008 Motorola confidentialVersion:00
10
Right Angle Connector InstallationRight Angle Connector Installation
ApprovedApprovedNot ApprovedNot Approved
Proper installation using the right angle connectors toavoid any bend. Andrew metallic clamps is used to fixthe splitter in the cable tray
The feeder cables are not inside the cable tray and notprotected as well as the splitter is not fixed
8/6/2019 1.4.3 - Quality Manual for IBS DU
11/34
10/8/2008 Motorola confidentialVersion:00
11
Splitter FixationSplitter Fixation
ApprovedApprovedNot ApprovedNot Approved
Bad splitter fixationSplitter fixed correctly using 2 fixations. The splittershould installed in a secured place.
8/6/2019 1.4.3 - Quality Manual for IBS DU
12/34
10/8/2008 Motorola confidentialVersion:00
12
Splitter FixationSplitter Fixation
ApprovedApprovedNot ApprovedNot Approved
Bad splitter fixationSplitter fixed correctly using Andrew metal clamp.The splitter should installed in a secured place.
8/6/2019 1.4.3 - Quality Manual for IBS DU
13/34
10/8/2008 Motorola confidentialVersion:00
13
Splitter FixationSplitter Fixation
ApprovedApprovedNot ApprovedNot Approved
Use existing (GSM or low current) cable tray assupports
Not allowed to use any existing pipes or HVPower cable tray
8/6/2019 1.4.3 - Quality Manual for IBS DU
14/34
10/8/2008 Motorola confidentialVersion:00
14
Splitter LabelingSplitter Labeling
ApprovedApprovedNot ApprovedNot Approved
Splitter labeling is not according to du standardsAcceptable labeling using: Quick laser labeling system,Label color: YellowFont Type: Arial Bold,Font Height: 05-20mmFont Color: Black
8/6/2019 1.4.3 - Quality Manual for IBS DU
15/34
10/8/2008 Motorola confidentialVersion:00
15
--10 db Directional Coupler Labeling10 db Directional Coupler Labeling
Approved labeling for the -10db Directional Coupler using:-Quick laser labeling system, label color: YellowFront Type: Arial Bold, Front Height: 05-20mmFront Color: BlackThe same will be applied for the -6db & -8db
8/6/2019 1.4.3 - Quality Manual for IBS DU
16/34
10/8/2008 Motorola confidentialVersion:00
16
Hybrid Coupler InstallationHybrid Coupler Installation
ApprovedApprovedNot ApprovedNot Approved
Poor Hybrid Coupler fixation
The Hybrid Coupler is fixed correctly using Andrewmetallic clamp
8/6/2019 1.4.3 - Quality Manual for IBS DU
17/34
10/8/2008 Motorola confidentialVersion:00
17
Triplexer InstallationTriplexer Installation
ApprovedApprovedNot ApprovedNot Approved
The triplexers are perfectly installedThe fixation and the labeling of the triplexers isbadly done
8/6/2019 1.4.3 - Quality Manual for IBS DU
18/34
10/8/2008 Motorola confidentialVersion:00
18
Hybrid Coupler & Triplexer InstallationLayout
Standard Template of installing the Hybrid Coupler & theTriplexer for each Sector in the GSM room
8/6/2019 1.4.3 - Quality Manual for IBS DU
19/34
8/6/2019 1.4.3 - Quality Manual for IBS DU
20/34
10/8/2008 Motorola confidentialVersion:00
20
Antenna Installation in the Open AreaAntenna Installation in the Open Area
ApprovedApprovedNot ApprovedNot Approved
Andrew clamps & Antenna label badly installed Antenna label & Andrew clamp are installedaccording to DU standards
8/6/2019 1.4.3 - Quality Manual for IBS DU
21/34
10/8/2008 Motorola confidentialVersion:00
21
Clamps InstallationClamps Installation
ApprovedApprovedNot ApprovedNot Approved
The feeder cable is not well fixed Andrew clamps are required and installed to supportthe feeder cable, the distance between 02 clamps is:-70 cm for feeder cable90 cm for 7/8 feeder cable120 cm for 1.5/8 feeder cable
8/6/2019 1.4.3 - Quality Manual for IBS DU
22/34
10/8/2008 Motorola confidentialVersion:00
22
Feeders Supports
Standard template for feeder
supports installation
8/6/2019 1.4.3 - Quality Manual for IBS DU
23/34
10/8/2008 Motorola confidentialVersion:00
23
3M Free Standing Pole Installation3M Free Standing Pole Installation
ApprovedApprovedNot ApprovedNot Approved
Step ladders are installed on the 03mfree standing pole. The pole isconsidered as unsafe
ITS safety ladder is installed to havethe free standing pole safe to climb
8/6/2019 1.4.3 - Quality Manual for IBS DU
24/34
A L dd S d dA L dd S d d
8/6/2019 1.4.3 - Quality Manual for IBS DU
25/34
10/8/2008 Motorola confidentialVersion:00
25
Access Ladder StandardsAccess Ladder Standards
8/6/2019 1.4.3 - Quality Manual for IBS DU
26/34
10/8/2008 Motorola confidentialVersion:00
26
3M Wall Mounted Installation3M Wall Mounted Installation
ApprovedApprovedNot ApprovedNot Approved
Unacceptable step ladder are installed on the 3m
MW-Pole
safety ladder is installed to have the pole safe to
climb & Carriage stopper should be installedcorrectly as shown above
St d d O td L b li gStandard Outdoor Labeling
8/6/2019 1.4.3 - Quality Manual for IBS DU
27/34
10/8/2008 Motorola confidentialVersion:00
27
Standard Outdoor LabelingStandard Outdoor Labeling
8/6/2019 1.4.3 - Quality Manual for IBS DU
28/34
10/8/2008 Motorola confidentialVersion:00
28
Cable Tray InstallationCable Tray Installation
ApprovedApprovedNot ApprovedNot Approved
The cable tray is installed without its coverIts support is badly doneThe cable tray is not fixed to its support
The cable tray is installed with its coverZ channels are used to fix the cable tray to its support
Standard Outdoor EarthingStandard Outdoor Earthing
8/6/2019 1.4.3 - Quality Manual for IBS DU
29/34
10/8/2008 Motorola confidentialVersion:00
29
Standard Outdoor EarthingStandard Outdoor Earthing
Note:- All dimensions above in mm
GSM room earth bar should be conform with the standards shown above
8/6/2019 1.4.3 - Quality Manual for IBS DU
30/34
10/8/2008 Motorola confidentialVersion:00
30
Cable Tray InstallationCable Tray Installation
ApprovedApprovedNot ApprovedNot Approved
Dont use screw with nut to fix cable tray cover Use screw only to fix the cover (easy fordisassemble)
8/6/2019 1.4.3 - Quality Manual for IBS DU
31/34
10/8/2008 Motorola confidentialVersion:00
31
Cable Tray InstallationCable Tray Installation
ApprovedApprovedNot ApprovedNot Approved
Cutting any metal part of (cable tray or cableladder) should be followed by prevent This partfrom corrosion
Use metallic paint for this purpose (the paintingshould be done before assemble the Cableladder or tray so it will not affect on thesurrounding area
8/6/2019 1.4.3 - Quality Manual for IBS DU
32/34
10/8/2008 Motorola confidentialVersion:00
32
Cable Tray InstallationCable Tray Installation
ApprovedApprovedNot ApprovedNot Approved
Wrong way to install the Earthing cable (notallowed to use the front edge of cable tray)
Use the back edge to install the Earthing cable &each two pieces of cable tray should be connectedto each other by earth cable
8/6/2019 1.4.3 - Quality Manual for IBS DU
33/34
10/8/2008 Motorola confidentialVersion:00
33
Earthing SystemEarthing System
ApprovedApprovedNot ApprovedNot Approved
For outdoor purpose not allowed to use theEarthing Cable to connect the MW-pole earth barto the existing grounding system.
Use copper tape for the connection between MW-Pole earth bar and the existing grounding system
& Use square tape clamp for the joint point
8/6/2019 1.4.3 - Quality Manual for IBS DU
34/34
10/8/2008 Motorola confidentialVersion:00
34
Store RoomStore Room
ApprovedApprovedNot ApprovedNot Approved
The material should be stored correctlyThe material is properly stored and its theresponsibility of the subcontractor to ensure thestorage of the material in site