13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
1
Gas Flow Modelling in Design of the Vacuum System
for of the Synchrotron Light Source
O.B. Malyshev
ASTeC Vacuum Science groupCCLRC Daresbury Laboratory,
Warrington WA4 4AD, UK
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
2
Outline• Input parameters• Sources of gas in vacuum chamber• Interpretation of experimental data• SR from a dipole magnet • Desorption• Models• Pressure distributions
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
3
Input parametersAn example of parameters as for diamond• Beam parameters: I=0.300 A, E=3 GeV• Required average pressure: <10-9 mbar • Beam vacuum chamber is uniform:
82 mm x 38 mm• SR from Dipole:
Ec = 8.37 keV, = 1.151017 photons/mrad
• SR from dipole on crotch-absorber: = ~6.01018 photons (approximate value)
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
4
Sources of gas in the SLS vacuum system
• Leaks
• Residual gas
• Thermal outgassing
• Photon stimulated desorption
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
5
Sources of Gas in a Vacuum System: Thermal Desorption
Thermal desorption
(or thermal outgassing) means:– Molecules adsorbed on the surface
(initially or after the air venting) and desorbing when vacuum chamber is pumped
– Molecules diffusing through the bulk material of the vacuum chamber, entering the surface and desorbing from it
Outgassing rate depends on many factors: choice of material, cleaning procedure, pumping time, etc...
AirVacuum
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
6
Sources of Gas in a Vacuum System: PSD
e-
H2
H2
H2O
CO2
CH4
CO
Photon stimulated desorption (PSD) is one of the most important sources of gas in the presence of SR.
Gas molecules may be desorbed from a surface when and where photoelectrons leave and arrive at a surface
e-
The same as thermal desorption, PSD depends on:
• Choice of material • Cleaning procedure• History of material• Pumping time
Additionally it depends on
• Energy of photons• Photon flux• Integral photon dose• Temperature
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
7
Sources of Gas in a Vacuum System: PSD
Photodesorption yields, (molecules/photon), as a function of accumulated photon dose, D, for different materials measured up to certain doses, these results are extrapolated for use in the design of new machines
PSD yield for CO for prebaked and in-situ baked stainless steel vacuum chambers. Yields for doses higher then 1023 photons/m (1 to 10 Amphrs for diamond) are extrapolations.
165.0,00
D
D
Photodesorption yield at room temperature as function of accumulated photon dose can be described as:
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
8
Sources of Gas in a Vacuum System: ESD
F. Billard, N. Hilleret, G. Vorlaufer. Some Results on the Electron Induced Desorption Yield of OFHC Copper. Vacuum Technical Note 00-32, December 2000, CERN, Geneva
Electron stimulated desorption (ESD) can be a significant gas source in a vacuum system in a number of cases when the electrons bombard the surface.
The same as thermal desorption and PSD, ESD depends on:
• Choice of material • Cleaning procedure• History of material• Pumping time
Additionally it depends on:
• Energy of electrons impacting the surface
• Electron flux to the surface
• Integral electron dose• Temperature
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
9
Vacuum chamber without an ante-chamber
• SR directly irradiate the strip with width a
a
b
e-beamSR
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
10
Vacuum chamber without an ante-chamber
• SR directly irradiate the strip with width a
• Some photons are reflected
a
b
e-beamSR
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
11
Vacuum chamber without an ante-chamber
• SR directly irradiate the strip with width a
• Some photons are reflected
• Photo-electrons are emitted and hit a vacuum chamber uniformly (for round tube)
a
b
e-beamSR
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
12
Vacuum chamber without an ante-chamber
• SR directly irradiate the strip with width a
• Some photons are reflected
• Photo-electrons are emitted and hit a vacuum chamber uniformly (for round tube)
• Gas molecules are desorbed where the electrons emitted and where they hit the wall
a
b
e-beamSR
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
13
Vacuum chamber without an ante-chamber
• In the presence of dipole field B the gas desorption most of electrons hit the wall near the intensively irradiated strip a
• Switching B on and off change the distribution of the electrons hitting the wall and therefore gas desorption.
a
b
e-beamSR
B
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
14
Effect of magnetic field on photo-desorption
PAC-1993, p.3876
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
15
Vacuum chamber without an ante-chamber
• If the directly irradiated strip is narrow: a << b, then conditioned very fast.
• Initially a0 = b0 qa>>qb
• After some short time there will be: a << b and qaqb
• I.e. gas desorption is quite uniform radially
a
b
e-beamSR
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
16
Vacuum chamber with an ante-chamber
• Part of SR directly irradiate the strips above and below the slot to the antechamber
• Photoelectrons may be repelled by the beam into the ante-chamber
• Some photons are backscattered from the crotch absorber to the ante-chamber
• Photoelectrons from the crotch absorber are distributed inside the antechamber
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
17
Vacuum chamber with an ante-chamber
• Part of SR directly irradiate the strips above and below the slot to the antechamber
• Photoelectrons may be repelled by the beam into the ante-chamber
• Some photons are backscattered from the crotch absorber to the ante-chamber
• Photoelectrons from the crotch absorber are distributed inside the antechamber
Intensive conditioning
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
18
Vacuum chamber with an ante-chamber
• Part of SR directly irradiate the strips above and below the slot to the antechamber
• Photoelectrons may be repelled by the beam into the ante-chamber
• Some photons are backscattered from the crotch absorber to the ante-chamber
• Photoelectrons from the crotch absorber are distributed inside the antechamber
Intensive conditioning
No conditioning 0
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
19
Vacuum chamber with an anti-chamber
• There is distributed photon stimulated desorption in the vacuum chamber with an ante-chamber
• The lower photon and photo-electron flux onto the vacuum chamber walls lead to lower initial desorption flux but cause lower beam conditioning and therefore very little or no benefit in long term
• Meanwhile the antechamber is essential to let SR out => crotch absorber vacuum chambers.
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
20
SR from a dipole magnet
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
21
Photodesorption from a stainless steel vacuum chamber
pre-baked VC: pre-baked at 200C for 24 hrs (but not baked in-situ) in-situ baked: baked in-situ at 200C for 48 hrs[1] C.L. Foerster, et al, J.Vac.Sci.Technol A8(3) (1990) 2856[2] C. Herbeaux, et al, J.Vac.Sci.Technol A17(2) (1999) 635Extrapolation above Dmax!
D-0.66 D-0.95
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
22
Photodesorption yield as a function of distance from a dipole magnet
•Initial desorption yields after ex-situ baking is 20 times better than after in-situ baking of vacuum chamber;• Desorption yields are similar in both chambers after 100 Ah conditioning and vary along the vacuum chamber
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
23
Desorption flux as a function of distance from a dipole magnet
I.e. the photon flux may differ in about 104 times but after shot conditioning (1Ah) the difference in ougassing is less than factor 10.
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
24
Models
• Analytical 1D diffusion model• Monte-Carlo simulations (3D)• Method of angular coefficient (2D and 3D)
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
25
A model of dynamic desorption processes in a beam vacuum chamber (1)
2
2
dz
nducnq
dt
dnV
where z is the longitudinal axis of the vacuum chamber; n is the gas volume density; V is the vacuum chamber volume; q is the gas desorption flux; c is the distributed pumping speed
Gas desorption q consists of two main sources: thermal and photon stimulated desorption:
Fq twhere t is the thermal desorption yield,
F is the vacuum chamber surface area, is the photon stimulated desorption yield,
is the synchrotron radiation photon flux.
The equations of gas dynamic balance inside a vacuum chamber:
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
26
A model of dynamic desorption processes in a beam vacuum chamber (2)
In the quasi-equilibrium state when the condition V dn/dt = 0 is satisfied:
02
2
qcndz
ndu
This second order differential equation for the function n(z) has two solutions:
where the constants C1 and C2 depend on the boundary conditions.
0)(
02
)(
21
212
cforeCeC
c
qzn
cforCzCzu
qzn
zu
c
b
zu
c
b
aa
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
27
A model of dynamic desorption processes in a beam vacuum chamber (3)
All vacuum chamber along the beam can be fragmented on N elements with c = 0 and c > 0. Every i-th element lying between longitudinal co-ordinates zi-1 and zi will be described by above
equations with two unknowns C1i and C2i. The boundary
conditions are and
A system of 2N–2 equations with 2N–2 unknowns which can be easily solved.
iiii znzn 1 zznzzn iiii )()( 1
.
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
28
Comparison between models
model Diffusion Monte-Carlo
Accuracy 1D simplified model 3D accurate model
Complicate shape
Not accurate Accurate
Long structures
Short time calculations Very long calculations
Optimisation Easy to change and calculate
Time consuming modelling and calculations
Molecular beaming
Does not consider Accurate
Use Good knowledge of gas dynamic is essential
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
29
Monte-Carlo for modelling pumping port
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
30
Pressure profile along the arc
Comparison between the analytical methodology and a Monte-Carlo simulation (MOLFLOW written by R. Kersevan) for some elements of the diamond vacuum chamber
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
31
Pressure profile along the arc after 100 Ahrs beam conditioning
Average pressure
without a beam:
<Pt> = 110-9 mbar
due to SR photons only:
<P> =110-9 mbar
Sum (i.e with a beam):
<Pdin> = <Pt> + <P
>=
= 210-9 mbar
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
32
Pressure profile along front ends after 30 Ahrs beam conditioning
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
33
Example of pressure profile
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
34
Example of pressure profile
Pumping unitsGas injection
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
35
Conclusions
• Vacuum chamber without an ante-chamber is not necessary need in-situ baking (but requires ex-situ one).
• Vacuum chamber with an ante-chamber needs in-situ baking • There are different methods to calculate the pressure profile,
choice of method or their combination depends on task, timescale, required accuracy, etc.
• There are no computing programme to optimise the design of vacuum chamber – each machine quite unique and there are many ways of optimisation.
• There is a lack of data for photo-desorption at high photon dose (above 1023 photons/m).
13/09/2005 Vacuum Systems for Synchrotron Light Sources Workshop, Barcelona, Spain
36