7
WIEN FILTER #1 (Ø=2,3,4 mm) *Nominal Operational Settings* APERTURE (1/3) Rapid Access CARM RM100 P1 RAS INJECTOR QUICK REFERENCE DRAWING VIEWER VIEWER PRE-BUNCHER (1497 MHz) HARP VIEWER SOLENOID SPIN FLIPPER SOLENOIDS CORRECTOR CORRECTOR CORRECTOR CORRECTOR BEAMLINE VALVE ION PUMP WIEN MAGNET WIEN HV VIEWER 15° DIPOLE Y GUN #2 CORRECTOR SOLENOID PAGE 1 SOLENOID (SW) MFH2I01 CORRECTOR MBH2I03 H&V BEAMLINE VALVE VIEWER BPM BPM/ BPM / CORRECTOR P-CUP (1 kW) ITV1I02 MBH1I02 H&V MFB1I02 MHB1I03 H&V ITV1I03 MWF1I04 IWF1I04DCV ITV1I04 MBH1I04 H&V MFG1I04 A VIP1I05 IHA1I06 ITV1I07 VBV1I07 MFQ0I01 MBH0I01 H&V CORRECTOR MBH2I02 H&V QUAD QUAD + RIN1I05 A1 MFG1I04 B DP CAN VDP1I05 IPM0I01 / MQU0I01 / IPM0I01A ITV0I01 WIEN FILTER #2 VERTICAL WIEN FILTER HORIZONTAL WIEN FILTER WIEN MAGNET MWF0I02 BPM / QUAD / BPM VIEWER WIEN HV IWF1I04DCV Optical Table Region (for more detail see http://opsntsrv.acc.jlab.org/ops_docs/ online_document_files/MCC_online_files/ injector_laser_table_element_definitiions.pdf) D. Moser Revision 16: 10 Oct 2019 File: 12GeV_injector_quick_reference_Dwg_rev16.ai VIP1I02 ION PUMP MQW1I03 MQW1I04 IPM1I06 / MBH1I06 H&V IPM1I04 / PSS KICKERS SBK0I01 H&V QUAD MQW0I01A IFY0IA1 CORRECTOR MHD0I01A H&V IPM1I02 IFY1I07 MHB1I05 H&V VIP VIP1I03 ION PUMP ITV2I02 MDS1I01 VBV2I02 VIP ION PUMP VIP1I07 VIP ION PUMP VIP0I01 VIP ION PUMP VIP1I04 VIP VIP ION PUMP VIP1I01 VIP VIP VIP ION PUMPS (x4) VIP2I01A,B,C (DIG 11) VIP BROCK CAVITY ICB0I01 BPM IPM2I01 BPM IPM2I02 CORRECTOR MBH2I01H&V VIP SF6 HVPS Gun HV (kV) 0.335 0.387 0.494 0.630 Electron Momentum (MeV/c) Relativistic Factor ( γ ) Fraction of Speed of Light 100 130 200 300 0.335 0.387 0.494 0.630 1.196 1.254 1.391 1.587 0.548 0.604 0.695 0.777 Bldg 53, Injector Service Building, Above-Ground Phones: x6165 -- (3x+base) Cordless Phones x5167 -- Outside PSS D1, in between D1 and D2, outside D2 (3 phones) VIP ION PUMP VIP3I01 BEAMLINE VALVE VBV3I02 (usually closed and controls disconnected) x6207 -- by tunnel entrance/ 1st R/S Box x6208 -- both outside by camera and inside laser room (and by R/S box 2)

12GeV injector quick reference rev16 · 12 GeV Song Sheets: ACC-000-2845-001 rev. - ACC-000-2845-002 rev. 4 ACC-000-2845-003 rev. 11 ACC-000-2845-004 rev. 9 ACC-000-2845-029 rev

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 12GeV injector quick reference rev16 · 12 GeV Song Sheets: ACC-000-2845-001 rev. - ACC-000-2845-002 rev. 4 ACC-000-2845-003 rev. 11 ACC-000-2845-004 rev. 9 ACC-000-2845-029 rev

WIEN

FILTER #1

(Ø=2,3,4 mm)

*Nominal Operational Settings*

APERTURE

(1/3) Rapid Access CARM RM100 P1 RAS

INJECTOR QUICK REFERENCE DRAWING

VIEWER

VIEWER

PRE-BUNCHER(1497 MHz)

HARP

VIEWER

SOLENOID

SPIN FLIPPERSOLENOIDS

CORRECTOR

CORRECTOR

CORRECTOR

CORRECTOR

BEAMLINE VALVE

ION PUMP

WIEN MAGNET WIEN HV

VIEWER

15° DIPOLE

Y

GUN #2

CORRECTOR

SOLENOID

PAGE 1

SOLENOID (SW) MFH2I01CORRECTOR MBH2I03 H&V

BEAMLINE VALVEVIEWER

BPM

BPM/

BPM / CORRECTOR

P-CUP (1 kW)

ITV1I02

MBH1I02 H&V

MFB1I02MHB1I03 H&V

ITV1I03

MWF1I04IWF1I04DCV

ITV1I04

MBH1I04 H&V

MFG1I04 A

VIP1I05

IHA1I06

ITV1I07

VBV1I07MFQ0I01

MBH0I01 H&V

CORRECTOR MBH2I02 H&V

QUAD

QUAD +

RIN1I05

A1

MFG1I04 B

DP CAN VDP1I05

IPM0I01 / MQU0I01 /

IPM0I01A

ITV0I01

WIEN

FILTER #2VERTICAL WIEN FILTER

HORIZONTAL WIEN FILTER WIEN MAGNET MWF0I02

BPM / QUAD /

BPM

VIEWER

WIEN HV IWF1I04DCV

Optical Table Region (for more detail see http://opsntsrv.acc.jlab.org/ops_docs/online_document_files/MCC_online_files/injector_laser_table_element_definitiions.pdf)

D. MoserRevision 16: 10 Oct 2019File: 12GeV_injector_quick_reference_Dwg_rev16.ai

VIP1I02ION PUMP

MQW1I03

MQW1I04

IPM1I06 / MBH1I06 H&V

IPM1I04 /

PSS KICKERS SBK0I01 H&V

QUAD MQW0I01AIFY0IA1 CORRECTOR MHD0I01A H&V

IPM1I02

IFY1I07

MHB1I05 H&V

VIP

VIP1I03ION PUMP

ITV2I02

MDS1I01

VBV2I02

VIP

ION PUMP VIP1I07

VIP

ION PUMP VIP0I01

VIP ION PUMP VIP1I04

VIP

VIP ION PUMP VIP1I01

VIPVIPVIP ION PUMPS (x4) VIP2I01A,B,C (DIG 11)

VIP

BROCK CAVITY ICB0I01

BPM IPM2I01

BPM IPM2I02

CORRECTOR MBH2I01H&V

VIPSF6

HVPSGun HV

(kV)

0.335

0.387

0.494

0.630

ElectronMomentum

(MeV/c)

RelativisticFactor

( γ )

Fractionof Speedof Light

100

130

200

300

0.335

0.387

0.494

0.630

1.196

1.254

1.391

1.587

0.548

0.604

0.695

0.777

Bldg 53, Injector Service Building, Above-Ground Phones:x6165 -- (3x+base) Cordless Phonesx5167 -- Outside PSS D1, in between D1 and D2, outside D2 (3 phones)

VIPION PUMP VIP3I01

BEAMLINE VALVE

VBV3I02(usually closed and controls disconnected)

x6207 -- by tunnel entrance/ 1st R/S Box

x6208 -- both outside by camera and inside laser room (and by R/S box 2)

Page 2: 12GeV injector quick reference rev16 · 12 GeV Song Sheets: ACC-000-2845-001 rev. - ACC-000-2845-002 rev. 4 ACC-000-2845-003 rev. 11 ACC-000-2845-004 rev. 9 ACC-000-2845-029 rev

¼ CRYOMODULE 0L02

CAPTURETnom= 500keV 0.86c

BEAMLINE VALVE

PAGE 2

CORRECTOR

MFA0I03

MBH0I03 H&V

MBH0I02A H&V / IPM0I02A(Ø=4,6,8 mm)APERTURE

SOLENOID

A2CORRECTOR / BPM

CORRECTOR

CORRECTOR/BPM

CORRECTOR

CORRECTOR

SKEW QUAD

APERTURE (Ø=6mm)

SOLENOID

VIEWER +

SOLENOID

SOLENOID

MFD0I04

ITV0I04 +

MBH0I04 H&V

MBH0I05 H&V / IPM0I05

MFA0I05

VIEWER + ION PUMP ITV0I05 + VIP0I05

VIEWER ITV0I06

MAD0I06A H&V FARADAY CUP #1 (1 kW) IFY0I06

MBH0I06 H&V

DIPOLE MBO0I06

MFL0I07

MAD0I07 H&V

YAO CAVITY

MASTER SLITSLIT A SLIT BSLIT C VIEWERCENTER PLUG

VIEWER ITV0I06A

RF BUNCHER CAVITY (1497 MHz)

CORRECTOR

A3

APERTURE (Ø=6.5mm)

SOLENOID MFA0I06

VBV0I07

DP CAN + ION PUMP

VBV0L00A

VBV0L00B

BLM (MPS)

BEAMLINE VALVE

BEAMLINE VALVE

BLM (MPS)

MQS0I07

MFD0I04A

ILM0I07

VDP0I07 + VIP0I07 (DIG 4)

ICV0I07

ILM0L01A

CHOPPER #1 (499 MHz)

EARTH CORRECTING COIL

EARTH CORRECTING COIL

CORRECTOR

A4

MBH0I07A H&V

VIEWER +ION PUMP

ITV1D00VIP1D00

BEAMLINE VALVE VBV1D00

CORRECTOR MAD1D00 H&V

500 keV Dump (1 kW) IDL1D00

HARP (UNPOWERED)

1D SPECTROMETER

BPM / QUAD IPM0I02 / MQU0I02

IHA0I02HARP (unpowered)

BEAMLINE VALVE

CORRECTOR MBH0I02 H&V

IFY0IA2 ION PUMP VIP0I02VIP

QUAD MQU0I02A

MED0I03

ION PUMP VIP0I03

ION PUMP VIP0I04

MEE0I05

ION PUMP VIP0I06

IFY0IA3

IFY0IA4

IPM0I07BPM

ITV0I02VIEWER

VBV0I02

SOLENOID(same power supply as MFD0I04)

ION PUMP VIP0I04A

CAPTURE ION PUMPS (x4) VIP0I06A,C,D,E

CHOPPER #2 (499 MHz)

B

C

Downstream Electron View

SLIT GEOMETRY

2mm Ø

A

Ø = 60° of 1497 MHz

30mm Ø

= 20° of 499 MHz

ION PUMP VIP0L00VIP

IHA1D00

VIPVIPVIPVIP

VIP

VIP

VIP

VIP

VIP

Tgain= 5.75 MeV

(DIG 2)

(DIG 3)

(DIG 3)

(DIG 3)

VIP

(DIG 3)

VIP

(DIG 7)

(DIG 7)

VIP

Bend angle = 30° = 0.523599 radian

Chopper Viewer Diameter:2.13 in (54.10 mm)

D. MoserRevision 16: 10 Oct 2019File: 12GeV_injector_quick_reference_Dwg_rev16.ai

(2/3) Rapid Access CARM RM100 P2 RAS

ION PUMP VIP0I06B

SOLENOID (UNPOWERED) MFA1D00

*

*VIP 0L02 ION PUMP VIP0L0020

COLD CATHODE GAUGE VCG0L0010

Tnom= 6.3MeV 0.997c

Page 3: 12GeV injector quick reference rev16 · 12 GeV Song Sheets: ACC-000-2845-001 rev. - ACC-000-2845-002 rev. 4 ACC-000-2845-003 rev. 11 ACC-000-2845-004 rev. 9 ACC-000-2845-029 rev

CORRECTORS(Two sets of coils for each plane ganged together in series)

ILM0L04A

BEAMLINE VALVE VBV0L04A

BLM (MPS)

CORRECTOR

VIEWER + ION PUMP

QUAD

BPM / SKEW QUAD

BLM (MPS)

BEAMLINE VALVE VBV0L04BITV0L05 + VIP0L05A

MAT0L05 H&V

MQJ0L05BEAMLINE VALVE + VBV0L05A +

BEAMLINE VALVE + VBV0L05B +BLM (MPS)

IPM0L05 / MQS0L05

ITV0L01VIEWER

MBH0L01 H&V

BLM (MPS) ILM0L01B

DIFFERENTIAL PUMP

VBV0L01A

QUAD

MBH0L02 H&VCORRECTOR

BEAMLINE VALVE

MQJ0L01

ITV0L02 + VIP0L02VIEWER + ION PUMP

BPM/SKEW QUAD

MQJ0L02A

MDL0L02

QUAD

BCM (MPS)

CORRECTOR

FARADAY CUP #2 (1 kW)

ITV0L03 + VIP0L03

SKEW QUAD/BPM

QUAD

MQJ0L03

MQS0L03 / IPM0L03

MHB0L04 H&VCORRECTORBLM (MPS)

DIFF PUMP

BEAMLINE VALVEVIEWER

BPM / SKEW QUADQUAD

YAO CAVITY FAST VALVE

VBV0L03BITV0L04

MQJ0L04

VFV0L04

QUAD

MHB0L02A H&V

VBV2D00ABEAMLINE VALVEBLM (MPS)

DIPOLE

DUMP (1 kW)

HARP

BEAMLINE VALVE

IHA0L03

VBV0L03A

IPM0L01 / MQS0L01

VDP0L01

IPM0L02 / MQS0L02

BLM (MPS) ILM2D00B

VDP0L03

IPM0L04 / MQS0L04

ICV0L04

VIEWER+ION PUMP

QUAD

0L03

0L04Total Injector Energy = 123MeV

30Hz uses last four cavities

PAGE 3

Injector PSS Gate Tnom= 6.3MeV

MBH0L03 H&VCORRECTOR

MQJ0L03A

MQJ0L02

BPM/SKEW QUAD

IBC0L02

ILM2D00A

ILM0L06A

IFY0L03

3D MOTT POLARIMETER LINE

BEAMLINE VALVE VBV3D00A

ILM0L04B

ILM0L05

AC Boundary - Plastic Curtain

HELICITY CORRECTOR MHE0L01V

HELICITY CORRECTOR MHE0L02H

SKEW QUAD MQS0L01A

HELICITY CORRECTOR MHE0L03V

Y

X

CORRECTOR MHB0L01A H&V

SKEW QUAD MQS0L02B

CORRECTOR MHB0L02B H&V

ION PUMP VIP0L01 VIP

DPP ION PUMPS (x3) VIP0L01A,B,C

BEAMLINE VALVE VBV0L01B

BLM (MPS) ILM0L02

IDL2D00

VIPION PUMP VIP0L05B

VIP

ION PUMP VIP0L06

VIPION PUMPS VIP0L03C,D,E

VIP ION PUMP VIP0L04B

0L03 ION PUMPS (x4) VIP0L0420,30,40,50

0L04 ION PUMPS (x8) VIP0L051 -> 0L058

DUMP (1 kW LCW/34 W air) IDL3D00

VBV5D00IDL5D01DUMP (1 kW LCW)

BEAMLINE VALVE

VIPVIP

VIPION PUMP VIP0L04A

VIP

VIP

VIPVIPVIP

VIP

VIPVIPVIPVIP

VIPVIPVIPVIP

(DIG 4)

(DIG 5)

2D SPECTROMETER LINE*DETAIL ON P. 6

*DETAIL ON P. 6

5D BUBBLE CHAMBER LINE*DETAIL ON P. 6

VFV0L01FAST VALVE

Bend angle = -30° = -0.523599 radian

Bend angle = 25° = 0.436332 radian

Bend angle = -12.5° = -0.218166 radian

D. MoserRevision 16: 10 Oct 2019File: 12GeV_injector_quick_reference_Dwg_rev16.ai

(3/3) Rapid Access CARM RM100 P3 RAS

*

Y

HELICITY CORRECTOR MHE0L03H X

* **

*

*

*

COLD CATHODE GAUGE VCG0L0410

VIPVIPVIPVIP

COLD CATHODE GAUGE VCG0L05

*

Dump shielding removed. No beam in 5Dline allowed. (9/1/18)

x6208 -- by R/S box 2

Page 4: 12GeV injector quick reference rev16 · 12 GeV Song Sheets: ACC-000-2845-001 rev. - ACC-000-2845-002 rev. 4 ACC-000-2845-003 rev. 11 ACC-000-2845-004 rev. 9 ACC-000-2845-029 rev

PAGE 4

CORRECTORS

QUAD

DIFF PUMP +

CORRECTORS

QUAD

BPM

BEAMLINE VALVE VBV0L08

FAST VALVE VFV0L06

MDB0L07H & MDJ0L07V

MQB0L07

HARP

DIPOLE

QUAD

CORRECTORS

BPM

HARP IHA0L08

MDB0L08H & MDJ0L08V

MQB0L08

BEAMLINE VALVE

BPM

BEAMLINE VALVE VBV0L06A

MDB0L06H & MDJ0L06V

MQD0L06

VDP0L06 +

IPM0L07

IHA0L07

MBF0L06 “SPECTROMETER”

BLM (MPS)

IPM0L08

IDL4D00BLM

VBV4D00

IPM4D00ITV4D00

30Hz CORRECTOR

BPM

QUAD

HARP

VIEWER

CORRECTORS

IHA0L09B

BPM

ITV0L10

MDB0L10H & MDJ0L10V

QUAD

HARP

MBL0R01CHICANE DIPOLE

CORRECTORBPM

QUAD

CORRECTOR

BPMQUAD

MBL0R02CHICANE DIPOLE

IPM0R02

IPM0R01

MAT0L08H (MHF)

BLM (MPS)

MQB0L10

IHA0L10

IPM0L10

MAT0R01 H&V

MQD0R01

MAT0R02 H&V

MQD0R02

IPM0L09

MQB0L09DUMP (17 kW)

IHA4D00

ILM0L08

ILM4D00

ILM0R01

BPM IPM0L06

SLM

HARP

VIEWER

BPM IPM0L06A

30Hz CORRECTOR MAT0L07V (MHF)

VIEWER + ITV0L08 +

CORRECTORS MDB0L09H & MDJ0L09V

30Hz CORRECTOR MAT0L09H (MHF)

ISR0R02

4D (123 MeV) SPECTROMETER

ION PUMPS (x3) VIP0L06B,C,D

ARC 10 CROSS

VIP

BEAMLINE VALVE VBVAA19

BEAMLINE VALVE VBVAR08

ARC 10

ION PUMP VIPAA32CORRECTOR MDBAA32VQUAD MQPAA32

MXPAA31DIPOLE

Y

IOR4D00VIEWER

BEAMLINE VALVE VBV4D00A

VIPVIPVIP

VIP

VIP

ION PUMP VIP0L08

ION PUMP VIP0L10

VIP ION PUMP VIP0R02

* Note that the 4D Spectrometer and Arc 10share vacuum. Closest isolation valves in thearc are VBVAA19 and VBVAR08.

VIPION PUMP VIPAR01

*Incomplete on this diagram

MXPAA32DIPOLE

VIPION PUMP VIPAR07

Bend angle = 25° = 0.436332 radian

Injector Chicane Bend Angle-5.5° = -0.0959931 radian

D. MoserRevision 16: 10 Oct 2019File: 12GeV_injector_quick_reference_Dwg_rev16.ai

30Hz CORRECTOR MAT0L08V (MHF)

**

ION PUMP VIP4D00E

*

Page 5: 12GeV injector quick reference rev16 · 12 GeV Song Sheets: ACC-000-2845-001 rev. - ACC-000-2845-002 rev. 4 ACC-000-2845-003 rev. 11 ACC-000-2845-004 rev. 9 ACC-000-2845-029 rev

CORRECTORBPM

QUAD

BEAMLINE VALVE +

MBL0R04CHICANE DIPOLE

BEAMLINE VALVE

BEAMLINE VALVE

CORRECTOR MAT1L02 H&V

BPM / SKEW QUAD

QUAD

FAST VALVEBEAMLINE VALVE VBV1L02A

1L02 CRYOMODULE

VBV0R09 +

VBV1L00A

DIFF. PUMPING STATION

VBV1L01

MQD1L02

MAT0R07 H&VIPM0R07

MQD0R07

IPM1L02 / MQS1L02

YAO CAVITY

VDP1L01

VFV1L02

CORRECTOR

BPMQUAD

IPM0R03

HARP

CORRECTORBPMQUAD

CORRECTOR

BPMQUAD

VIEWER

IPM0R04

IPM0R05

MBL0R03CHICANE DIPOLE

CORRECTORBPMQUAD

BLM (MPS, lead shielded)

INSERTABLE DUMP (17 kW)BCM (PSS)

MQD0R06

ITV0R05

MAT0R03 H&V

MQD0R03

IHA0R05

MAT0R04 H&V

MQD0R04

MAT0R05 H&V

MQD0R05

MAT0R06 H&VIPM0R06

ILM0R06

SBC0R08

PAGE 5

MXT4R05

MZAAR03

IDL0R08

ICV1L01

BLM (Diagnostic) ILM1L01

BLM (MPS) ILM1L02

ROUGHING VALVE VRV0R05

CORRECTOR MAT0R08H

BPM

QUAD

IPM0R08

MQD0R08BLM (MPS) ILM0R08

MXR2R06

CORRECTOR MAT0R09 H&VBPM IPM0R09QUAD MQD0R09

MCB1L01HCORRECTOR

MCB1L01AHCORRECTORMCA1L01HCORRECTOR

SLM (UNPOWERED) ISR0R09

MBT1L00 H&VCORRECTORIPM1L00BPMMQN1L00QUAD

MBT1L01HCORRECTORIPM1L01BPMMQN1L01QUAD

DIPOLE

DIPOLE

DIPOLE

BCM (MPS) IBC0R08

VIP

VIP

VIP

VIP

ION PUMP VIP0R02A

ION PUMP VIP0R06

ION PUMP VIP0R08

ION PUMP VIP0R09

VIEWER ITV1L02 VIP ION PUMP VIP1L02

VIP

VIPVIP ION PUMPS VIP1L01A,B,C

WEST RECOMBINER / NORTH LINAC*Incomplete on this diagram

D. MoserRevision 16: 10 Oct 2019File: 12GeV_injector_quick_reference_Dwg_rev16.ai

*

*

* BLM (MPS) ILM0R09

*

*

* ILM0R04BLM (MPS)

CORRECTOR MBT0R08V

VIP ION PUMP VIP0R04

* ILM0R03BLM (MPS)

Page 6: 12GeV injector quick reference rev16 · 12 GeV Song Sheets: ACC-000-2845-001 rev. - ACC-000-2845-002 rev. 4 ACC-000-2845-003 rev. 11 ACC-000-2845-004 rev. 9 ACC-000-2845-029 rev

PAGE 6

0L02 Injector Diagnostic and Experimental Spurs Detail

MBH0L02 H&VCORRECTOR

ITV0L02 + VIP0L02VIEWER + ION PUMP

MQJ0L02A

MDL0L02

QUAD

BCM (MPS)

FARADAY CUP 2 (1 kW)

VBV2D00ABEAMLINE VALVE

BPM

ITV2D00VIEWER

BLM (MPS)

DIPOLE

DUMP (1 kW)

BLM (MPS) ILM2D00B

IPM2D00IHA2D00

QUAD

Tnom= 6.3MeV

MQJ0L02

HARP

IBC0L02M

ILM2D00A

IFY0L03

3D MOTT POLARIMETER LINE

CORRECTOR BEAMLINE VALVE VIEWER+ION PUMP

MOTT VIEWER

DIPOLE

MAD3D00 H&VVBV3D00AITV3D00 + VIP3D00A

IFL3D00

MDT3D01

HELICITY CORRECTOR MHE0L02HX

CORRECTOR MHB0L01A H&V

IDL2D00

TARGET LADDER ITG3D00ION PUMP VIP3D00B (DIG 12)

DUMP (1 kW LCW/34 W air) IDL3D00

VIP

MBH5D00 H&VVBV5D00VIP5D00+ ITV5D00MQD5D00

/ IPM5D00MBH5D00A H&V

MQD5D01

/ IPM5D01

+VIP5D01 (DIG 8)+ITV5D01

IDL5D01

CORRECTOR

QUADCORRECTOR /

QUAD

ELECTRON DUMP

FARADAY CUP

VIEWERION PUMP +

+ ION PUMP

BPM

BPM

BEAMLINE VALVE

VIP

(DIG 12)

(DIG 8)

VIP

VIP

ION PUMP VIP2D00A

(1 kW LCW)

MBH5D01 H&VCORRECTOR /

VCG5D01VACUUM COLD GAUGE

IFY5D01

5D BUBBLE CHAMBER LINE

VIP

+ VIEWER

2D 5 MeV SPECTROMETER LINE

VIP

PHOTON COLLIMATOR

BUBBLE CHAMBER

PHOTON DUMP

IPC5D01

ITG5D01

IDL5D01A

Bend angle = -30° = -0.523599 radian

Bend angle = 25° = 0.436332 radian

Bend angle = -12.5° = -0.218166 radian

BPM/SKEW QUAD IPM0L02 / MQS0L02

D. MoserRevision 16: 10 Oct 2019File: 12GeV_injector_quick_reference_Dwg_rev16.ai

Dump shielding removed. No beam in 5D-line allowed.

(9/1/18)

*

*

x6208 -- by R/S box 2

Page 7: 12GeV injector quick reference rev16 · 12 GeV Song Sheets: ACC-000-2845-001 rev. - ACC-000-2845-002 rev. 4 ACC-000-2845-003 rev. 11 ACC-000-2845-004 rev. 9 ACC-000-2845-029 rev

PAGE 7

Source Material Used:

12 GeV Song Sheets: ACC-000-2845-001 rev. - ACC-000-2845-002 rev. 4 ACC-000-2845-003 rev. 11 ACC-000-2845-004 rev. 9 ACC-000-2845-029 rev. 7

CEBAF Element Database queried at various times

Mike Spata’s notes on CED corrections dated 9/27/2013

Joe Grames’ notes on the beam line up to the PSS Gate from 10/1/2013

Revisions to the this document from Yan Wang received 10/8/2013

Revisions to this document from Joe Grames received 10/16/2013

Notes on injector ion pumps from Marcy Stutzman and Phil Adderley received 10/16/2013

Revisions to song sheet from Yan Wang received 10/18/2013

Mott dump operational limits (elog 3271441 2/27/2014)

Bubble Chamber Installation Kick-Off Meeting Notes (Grames, 5/28/2014)

Numerous personal inspections of the beam line and conversations with others

Revision Notes:

16: Added approximate locations of PSS Rapid Access CARMs. Differentiated symbols for helicity correctors vs 30Hz correctors. Updated BLM symbols and placement, cross-referencing https://opswiki.acc.jlab.org/wiki/BLM_List. Added cryomodule Cold Cathode Gauges and Ion Pumps. Added site phones. Corrected/differentiated nominal-E vs E-gain from RF element. Very likely last revision before 2020 Long Down Injector Upgrade.

15: Removed Gun #3 line and replaced with Cathode prep and storage chamber. Updated correctors in 2I-region.

14: Added drawing of viewer to P.2 by request (based on CEBAF DWG. No. 58432-C-0254 rev. A).

13: Corrected locations of the PSS and MPS BCM’s Used blue labels for RF components

12: Added Brock Cavity (ICB0I01) between A1 and Wien #2 (per email from Marcy 7/1/15)

11: Corrected position of MBH0L03 H/V (moved upstream of ITV0L03) MQS0L02 and IPM0L02 are colinear, rather than in series corrected per elog 3316769 1/8/2015

10: Removed ICB1D00 (Brock Cavity) from 1D line Added VFV0L01 fast valve Added detail page for 2D, 3D, and 5D lines (main drawing was too cluttered) Added bubble chamber components to 5D line Renamed 500 keV Spectrometer -> 1D Spectrometer Added bend angles for all spurs and the chicane Corrected various mistakes throughout

D. MoserRevision 16: 10 Oct 2019File: 12GeV_injector_quick_reference_Dwg_rev16.ai