1260 VXI SWITCHING CARD 1260-35 MULTIPLEXER / SCANNER PUBLICATION NO. 980673-006 RACAL INSTRUMENTS Racal Instruments, Inc. 4 Goodyear St., Irvine, CA 92618-2002 Tel: (800) 722-3262, FAX: (949) 859-7309 Racal Instruments, Ltd. 480 Bath Road, Slough, Berkshire, SL1 6BE, United Kingdom Tel: +44 (0) 8706 080134; FAX: +44 (0) 1753 791290 Racal Systems Electronique S.A. 18 Avenue Dutartre, 78150 LeChesnay, France Tel: +33 (1) 3923 2222; FAX: +33 (1) 3923 2225 Racal Systems Elettronica s.r.l. Strada 2-Palazzo C4, 20090 Milanofiori Assago, Milan, Italy Tel: +39 (02) 5750 1796; FAX +39 (02) 5750 1828 Racal Elektronik System GmbH. Frankenforster Strasse 21, 51427 Bergisch Gladbach, Germany Tel:+49 2204 92220; FAX: +49 2204 21491 Racal Australia Pty. Ltd. 3 Powells Road, Brookvale, NSW 2100, Australia Tel: +61 (2) 9936 7000, FAX: +61 (2) 9936 7036 Racal Electronics Pte. Ltd. 26 Ayer Rajah Crescent, 04-06/07 Ayer Rajah Industrial Estate, Singapore 0513. Tel: +65 7792200, FAX: +65 7785400 Racal Instruments, Ltd. Unit 5, 25F., Mega Trade Center, No 1, Mei Wan Road, Tsuen Wan, Hong Kong, PRC Tel: +852 2405 5500, FAX: +852 2416 4335 http://www.racalinst.com PUBLICATION DATE: April 10, 2000 Copyright 1997 by Racal Instruments, Inc. Printed in the United States of America. All rights reserved. This book or parts thereof may not be reproduced in any form without written permission of the publisher.

1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

1260 VXISWITCHING CARD

1260-35MULTIPLEXER / SCANNER

PUBLICATION NO. 980673-006

RACAL INSTRUMENTS

Racal Instruments, Inc.4 Goodyear St., Irvine, CA 92618-2002

Tel: (800) 722-3262, FAX: (949) 859-7309

Racal Instruments, Ltd.480 Bath Road, Slough, Berkshire, SL1 6BE, United Kingdom

Tel: +44 (0) 8706 080134; FAX: +44 (0) 1753 791290

Racal Systems Electronique S.A.18 Avenue Dutartre, 78150 LeChesnay, FranceTel: +33 (1) 3923 2222; FAX: +33 (1) 3923 2225

Racal Systems Elettronica s.r.l.Strada 2-Palazzo C4, 20090 Milanofiori Assago, Milan, Italy

Tel: +39 (02) 5750 1796; FAX +39 (02) 5750 1828

Racal Elektronik System GmbH.Frankenforster Strasse 21, 51427 Bergisch Gladbach, Germany

Tel:+49 2204 92220; FAX: +49 2204 21491

Racal Australia Pty. Ltd.3 Powells Road, Brookvale, NSW 2100, AustraliaTel: +61 (2) 9936 7000, FAX: +61 (2) 9936 7036

Racal Electronics Pte. Ltd.26 Ayer Rajah Crescent, 04-06/07 Ayer Rajah Industrial Estate, Singapore 0513.

Tel: +65 7792200, FAX: +65 7785400

Racal Instruments, Ltd.Unit 5, 25F., Mega Trade Center, No 1, Mei Wan Road, Tsuen Wan, Hong Kong, PRC

Tel: +852 2405 5500, FAX: +852 2416 4335

http://www.racalinst.com

PUBLICATION DATE: April 10, 2000

Copyright 1997 by Racal Instruments, Inc. Printed in the United States of America. All rights reserved.This book or parts thereof may not be reproduced in any form without written permission of the publisher.

Page 2: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

WARRANTY STATEMENT

All Racal Instruments, Inc. products are designed and manufactured to exacting standards and in fullconformance to Racal’s ISO 9001 procedures.

For the specific terms of your standard warranty, or optional extended warranty or service agreement, contactyour Racal customer service advisor. Please have the following information available to facilitate service.

1. Product serial number

2. Product model number

3. Your company and contact information

You may contact your customer service advisor by:

E-Mail: [email protected]

Telephone: +1 800 722 3262 (USA)+44(0) 8706 080134 (UK)+852 2405 5500 (Hong Kong)

Fax: +1 949 859 7309 (USA)+44(0) 1628 662017 (UK)+852 2416 4335 (Hong Kong)

RETURN of PRODUCT

Authorization is required from Racal Instruments before you send us your product for service or calibration. Callyour nearest Racal Instruments support facility. A list is located on the last page of this manual. If you areunsure where to call, contact Racal Instruments, Inc. Customer Support Department in Irvine, California, USA at1-800-722-3262 or 1-949-859-8999 or via fax at 1-949-859-7139. We can be reached at:[email protected].

PROPRIETARY NOTICE

This document and the technical data herein disclosed, are proprietary to Racal Instruments, and shall not,without express written permission of Racal Instruments, be used, in whole or in part to solicit quotations from acompetitive source or used for manufacture by anyone other than Racal Instruments. The information herein hasbeen developed at private expense, and may only be used for operation and maintenance reference purposes orfor purposes of engineering evaluation and incorporation into technical specifications and other documents whichspecify procurement of products from Racal Instruments.

Page 3: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

FOR YOUR SAFETY

Before undertaking any troubleshooting, maintenance or exploratory procedure, read carefully theWARNINGS and CAUTION notices.

This equipment contains voltage hazardous to human life and safety, and is capable of inflictingpersonal injury.

If this instrument is to be powered from the AC line (mains) through an autotransformer, ensure thecommon connector is connected to the neutral (earth pole) of the power supply.

Before operating the unit, ensure the conductor (green wire) is connected to the ground (earth)conductor of the power outlet. Do not use a two-conductor extension cord or a three-prong/two-prong adapter. This will defeat the protective feature of the third conductor in the power cord.

Maintenance and calibration procedures sometimes call for operation of the unit with power appliedand protective covers removed. Read the procedures and heed warnings to avoid “live” circuitpoints.

Before operating this instrument:

1. Ensure the instrument is configured to operate on the voltage at the power source. SeeInstallation Section.

2. Ensure the proper fuse is in place for the power source to operate.

3. Ensure all other devices connected to or in proximity to this instrument are properly grounded orconnected to the protective third-wire earth ground.

If the instrument:

- fails to operate satisfactorily- shows visible damage- has been stored under unfavorable conditions- has sustained stress

Do not operate until performance is checked by qualified personnel.

Page 4: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

This page was left intentionally blank.

Page 5: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

Amendment Page 6/98 1

NOTE FOR SYSTEMS WITH 1260-OPT 01T

The “Module-Specific Syntax” section of this manual shows the command syntax for the1260-01S Smart Card. If you are using the newer 1260-01T Smart Card, the commandswill NOT work as shown.

Consult the 1260-01T Manual for a description of the commands that may be used with the1260-01T Smart Card.

The channel numbers described in this manual are valid for the 1260-01T. The channelnumbers continue to be used for the 1260-01T.

The syntax of the commands that use channel numbers has changed for those cardscontrolled by the 1260-01T.

The new syntax used to close a channel is:

CLOSE (@ <module address> ( <channel> ) )

For example, for a relay module whose <module address> is set to 7, closing <channel> 0is performed with the command:

CLOSE (@7 (0))

Using the older 1260-01S, the command would be (as shown in this manual):

CLOSE 7.0

Many other command syntax differences exist. Please consult chapter 2 of the 1260-01Tmanual for a description of the commands that are available for the 1260-01T.

Page 6: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

Control Information for the 1260-35A

The 1260-35A operates as a 4-wire MUX. Thus, when a channel is operated, 2 relays must be operated inparallel. For each channel, when a bit of Control Register X is set (or cleared), the same bit of ControlRegister X+6 must also be set (or cleared).

Each channel on this module is therefore controlled by setting or clearing two bits, one each in two differentControl Registers. Control Registers on the module operate 8 channels simultaneously. There are eightcontrol bits per Control Register. Setting the bit to a 1 closes the relay; setting the bit to a 0 opens the relay.

The table below shows the mapping between logical channels used to operate the relay module in message-based mode and the bits within the Control Registers which may be used to operate the channel in register-based mode.

Each Control Register is located 2 addresses from the previous Control Register. That is, each ControlRegister is located at an odd address. This is shown in Table 2-2 of the 1260-01T manual. Control Register 0is located at the “Base A24 Address” for the module. Consult the “Register-Based Operation” Section ofChapter 2 of the 1260-01T manual for a description of calculating control register addresses

For example, when closing channel 13, both byte 1 and byte 7 must have bit 5 set.

Channel Control Register Control Bit0 0 and 6 01 0 and 6 12 0 and 6 23 0 and 6 34 0 and 6 45 0 and 6 56 0 and 6 67 0 and 6 78 1 and 7 09 1 and 7 110 1 and 7 211 1 and 7 312 1 and 7 413 1 and 7 514 1 and 7 615 1 and 7 716 2 and 8 017 2 and 8 118 2 and 8 219 2 and 8 320 2 and 8 421 2 and 8 522 2 and 8 623 2 and 8 724 3 and 9 025 3 and 9 126 3 and 9 227 3 and 9 328 3 and 9 429 3 and 9 530 3 and 9 631 3 and 9 732 4 and 10 033 4 and 10 134 4 and 10 235 4 and 10 336 4 and 10 437 4 and 10 538 4 and 10 639 4 and 10 7

Page 7: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

Channel Control Register Control Bit40 5 and 11 041 5 and 11 142 5 and 11 243 5 and 11 344 5 and 11 445 5 and 11 546 5 and 11 647 5 and 11 7

Page 8: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

Control Information for the 1260-35B

The following information describes the control-register-to-relay-channel mapping for a 1260-35B RelayModule. This information may be used to control a 1260-35B when using a 1260-01T in the register-basedmode of operation.

Each relay on this module is controlled by setting or clearing a single bit within a Control Register. ControlRegisters on the module operate 8 channels simultaneously. There are eight control bits per Control Register.Setting the bit to a 1 closes the relay; setting the bit to a 0 opens the relay.

The table below shows the mapping from logical channels to control bits. The logical channels are used whenoperating the relay module in message-based mode. The control bits within the Control Registers are used tooperate the module in register-based mode.

Each Control Register is located 2 addresses from the previous Control Register. That is, each ControlRegister is located at an odd address. This is shown in Table 2-2 of the 1260-01T manual. Control Register 0is located at the “Base A24 Address” for the module. Consult the “Register-Based Operation” Section ofChapter 2 of the 1260-01T manual for a description of calculating control register addresses.

Channel Control Register Control Bit0 0 01 0 12 0 23 0 34 0 45 0 56 0 67 0 78 1 09 1 110 1 211 1 312 1 413 1 514 1 615 1 716 2 017 2 118 2 219 2 320 2 421 2 522 2 623 2 724 3 025 3 126 3 227 3 328 3 429 3 530 3 631 3 732 4 033 4 134 4 235 4 336 4 437 4 538 4 639 4 740 5 041 5 142 5 243 5 3

Page 9: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

Channel Control Register Control Bit44 5 445 5 546 5 647 5 748 6 049 6 150 6 251 6 352 6 453 6 554 6 655 6 756 7 057 7 158 7 259 7 360 7 461 7 562 7 663 7 764 8 065 8 166 8 267 8 368 8 469 8 570 8 671 8 772 9 073 9 174 9 275 9 376 9 477 9 578 9 679 9 780 10 081 10 182 10 283 10 384 10 485 10 586 10 687 10 788 11 089 11 190 11 291 11 392 11 493 11 594 11 695 11 796 12 0

Page 10: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

i

Table of Contents

Chapter 1MODULE SPECIFICATION .......................................................................................................... 1-1

1260-35 Module Specification ................................................................................................... 1-1Specifications ........................................................................................................................ 1-2

Ordering Information ................................................................................................................. 1-3Safety........................................................................................................................................ 1-3Product Support ........................................................................................................................ 1-3

Chapter 2INSTALLATION INSTRUCTIONS ................................................................................................ 2-1

Unpacking and Inspection ......................................................................................................... 2-1Reshipment Instructions............................................................................................................ 2-1Option 01 Installation ................................................................................................................ 2-2Module Installation .................................................................................................................... 2-21260-35 ID Byte ........................................................................................................................ 2-2Configuration............................................................................................................................. 2-2Analog Bus................................................................................................................................ 2-4

Chapter 3MODULE SPECIFIC SYNTAX...................................................................................................... 3-1

1260-35 Module Specific Syntax ............................................................................................... 3-1Syntax ................................................................................................................................... 3-1CLOSE Command................................................................................................................. 3-2PSETUP Command............................................................................................................... 3-2PDATAOUT Command.......................................................................................................... 3-2Operation In Single-Wire Mode ............................................................................................. 3-3

Chapter 4DRAWINGS.................................................................................................................................. 4-1

Chapter 5PARTS LIST................................................................................................................................. 5-1

Page 11: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

ii

Chapter 6OPTIONAL HARNESS ASSEMBLIES.......................................................................................... 6-1

Chapter 7PRODUCT SUPPORT ................................................................................................................. 7-1

Product Support ........................................................................................................................ 7-1Reshipment Instructions ........................................................................................................... 7-1Support Offices ......................................................................................................................... 7-2

Page 12: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

iii

List of Figures

Figure 1-1, 1260-35 Signal Multiplexer/Scanner Module............................................................... 1-1

Figure 3-1, 1260-35 Block Diagram .............................................................................................. 3-7Figure 3-2, 1260-35 Pin Connections, Front View......................................................................... 3-8

List of Tables

Table 2-1, 1260-35 Jumper Installation......................................................................................... 2-3

Table 3-1, 1260-35 Channel Closure ............................................................................................ 3-3Table 3-1, 1260-35 Channel Closure (continued) ......................................................................... 3-5Table 3-1, 1260-35 Channel Closure (continued) ......................................................................... 3-6

Page 13: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

iv

This page was left intentionally blank.

Page 14: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Module Specification 1-1

Chapter 1

MODULE SPECIFICATION

1260-35 ModuleSpecification

The 1260-35 Signal Multiplexer/Scanner Module is a 1 x 96multiplexer. It switches two lines per channel and has thecapability of being configured as two 1 x 48 multiplexers, four 1 x24 multiplexers, eight 1 x 12 multiplexers, or sixteen 1 x 6multiplexers. The configuration is user selectable, but is suppliedby the factory in one 1 x 96 two-wire mode. A block diagram of themodule is shown in Figure 3-1

Figure 1-1, 1260-35 Signal Multiplexer/Scanner Module

Page 15: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Module Specification 1-2

Specifications Switch Configurations Four-wire Mode Any configuration Two-wire Mode Any configuration

User Connector 64-Pin (2 Row) IDC Quick Disconnect

Maximum Switchable Voltage 220VDC, 250VAC RMS(Terminal-Terminal or Terminal-Chassis

Maximum Switchable Current 1A DC or 1A RMS

Maximum Switchable PowerPer Channel 30W DC, 62.5VA AC

Path Resistance <0.5Ω (1 X 6 configuration) <1.0Ω (1 X 96 configuration)

Isolation Hi-Lo >7.5 X 108Ω

CapacitanceOpen Channel <600pf (1 x 96 configuration)

Channel-Chassis <60pf (1 x 6 configuration) <200pf (1 x 96 configuration) Hi-Lo <50pf (1 x 6 configuration) <600pf (1 x 96 configuration)

Bandwidth (50Ω Termination) >50 MHz (1 x 6 configuration) >15 MHz (1 x 48 configuration)

* A crimp connector kit is also available for this module (PIN 404975-001). A strain relief option can be ordered separately for this crimp connector kit.

Insertion Loss (50Ω ) <.1 dB to 100kHz1 x 6 Configuration <.5 dB to 1MHz

<1 dB to 10MHz

Insertion Loss (50Ω ) <3 dB to 8MHz1 x 96 Configuration

Crosstalk (50Ω termination) <-90 dB to 100kHz <-70 dB to 1 MHz <-23 dB to 10MHz

Cooling Requirement

Page 16: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Module Specification 1-3

Airflow 4.0 liters/sec Backpressure 0.5mm H20

Power Requirements +5V, Ipm 0.4A (2.8A with Option 01 installed) +24V, Idm 10mA per energized relay

Weight 3.07lbs (1.33Kg) 3.35lbs (1.51Kg) with Option 01 installed

Minimum Option 01 Firmware Revision 17.1

OrderingInformation

Model Number

1260-35

1260-35A

Description

1 X 96 Signal Multiplexer/Scanner, User Conn: IDC1 X 96 Signal Multiplexer/

Scanner, User Conn: Crimp

Part Number

404944

404944-001

Safety Refer to the “FOR YOUR SAFETY” page preceding the Table ofContents. Following all NOTES, CAUTIONS, and WARNINGS toensure personal safety and prevent damage to the instrument.

Product Support Racal Instruments has a complete Service and Parts Department.If you need technical assistance or should it be necessary to returnyour product for servicing, call 1-800-722-3262. If parts arerequired to repair the product at your facility, call 1-949-859-8999and ask for the Parts Department

When sending your instrument in for repair, complete the form inthe back of this manual.

Page 17: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Module Specification 1-4

This page was left intentionally blank.

Page 18: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Installation Instructions 2-1

Chapter 2

INSTALLATION INSTRUCTIONS

Unpacking andInspection

1. Before unpacking the switching module, check the exterior ofthe shipping carton for any signs of damage. All irregularitiesshould be noted on the shipping bill.

2. Remove the instrument from its carton, preserving the factorypackaging as much as possible.

3. Inspect the switching module for any defect or damage.Immediately notify the carrier if any damage is apparent.

4. Have a qualified person check the instrument for safety beforeuse.

CAUTION

Proper ESD handling procedures must always beused when packing, unpacking or installing any 1260Series cards. Failure to do so may cause damage tothe unit.

ReshipmentInstructions

1. Use the original packing material when returning the switchingmodule to Racal Instruments for servicing. The originalshipping carton and the instrument's plastic foam will providethe necessary support for safe reshipment.

2. If the original packing material is unavailable, wrap theswitching module in plastic sheeting and use plastic sprayfoam to surround and protect the instrument.

3. Reship in either the original or a new shipping carton.

Page 19: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Installation Instructions 2-2

Option 01Installation

Installation of the Option 01 to the 1260-35 is described in theInstallation section of the 1260 Series VXI Switching CardsManual.

ModuleInstallation

Installation of the 1260-35 Switching Module into a VXI mainframe,including the setting of DIP switches, is described in theInstallation section of the 1260 Series VXI Switching CardsManual. Configuration of the PCBA and setting of the DIP switchesSW1-5 and SW1-6 are described in the following sections.

1260-35 ID Byte Each configuration responds to different sets of values for<channel number>. The set of values the 1260-35 responds to iscontrolled by switch 5 on DIP switch 51 on the PCB. The switchsettings that correspond to the two configurations are as follows:

Configuration S1 Switch 5 S1 Switch 6

Four-wire Off Off

Two-wire On Off

Configuration The 1260-35 Scanner~u1tiplexer is a user configurable switchingmodule. Ten different configurations are available as follows:

1) Sixteen 1 x 6 two-wire scanner/multiplexers, P/N 404944-206

2) Eight 1 x 6 four-wire scanner/multiplexers, P/N 404944406

3) Eight 1 x 12 two-wire scanner/multiplexers, P/N 404944-212

4) Four 1 x 12 four-wire scanner/multiplexers, P/N 404944-412

5) Four 1 x 24 two-wire scanner/multiplexers, P/N 404944-224

6) Two 1 x 24 four-wire scanner/multiplexers, P/N 404944-424

7) Two 1 x 48 two-wire scanner/multiplexers, P/N 404944-248

8) One 1 x 48 four-wire scanner/multiplexers, P/N 404944448

9) One 1 x 96 two-wire scanner/multiplexers, P/N 404944-296

10) One 1 x 192 one-wire scanner/multiplexers, P/N 404944

Unless otherwise specified, the 1260-35 is shipped from thefactory in the 1 x 192 single wire configuration. Table 2-1 gives the

Page 20: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Installation Instructions 2-3

necessary information to configure the module into the otherpossible configurations

Table 2-1, 1260-35 Jumper Installation

An X indicates a jumper is to be fitted. An (X) indicates the jumper is optional depending onwhether access to the analog bus is required. A blank indicates no jumper is to be fitted.

16(1x6)2-wire

8(1x6)4-wire

8(1x12)2-wire

4(1x12)4-wire

4(1x24)2-wire

2(1x24)4-wire

2(1x48)2-wire

1(1x48)4-wire

1(1x96)2-wire

W2A, B (X) (X) (X)

W3A, B X X X X X X X

W4A, B X X X X X

W5A, B X X X X X X X

W6A, B X X X

W7A, B X

W8A, B X X X X X X X

W9A, B X X X X X

W10A, B X X X X X X X

W11A, B 1(1x192) 1-WIRE ONLY---> X

W12A,B X X X X X X X

W13A, B X X X X X

W14A, B X X X X X X X

W15A, B X

W16A, B X X X

W17A, B X X X X X X X

W18A, B X X X X X

W19A, B X X X X X X X

W20A, B (X) (X) (X)

Page 21: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Installation Instructions 2-4

Analog Bus In most of the above configurations, the 1260-35 may be userconfigured to access an analog bus (refer to Figure 3-1). Theanalog bus allows internal expansion for the configuration of largerscanner/multiplexers than the module may achieve alone, byproviding access to a common bus channel which may be daisychained to other modules via the front panel.

To connect the module to the analog bus, install jumpers W2A,W2B, W20A, and W20B.

Page 22: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Module Specific Syntax 3-1

Chapter 3

MODULE SPECIFIC SYNTAX

1260-35 ModuleSpecific Syntax

The Module Specific Syntax for the 1260-35 is required in the useof the OPEN and CLOSE commands. It will also appear in dataoutput by the Master in response to the PDATAOUT and PSETUPcommands.

Syntax The Module Specific Syntax for the 1260-35 SignalMultiplexer/Scanner module is as follows:

OPEN <module address>.<channel>[;<module address>. <channel>]

where <module address> is the switch card address. <channel> is the relay to be closed to connect an input to the output.

Note that Channels remain closed until opened by an OPENcommand, RESET command, VXI hard or soft reset, or power-off.

NOTE

The <module address> used here is NOT the VXIbusdefined logical address of the 1260 Series Master. Itis peculiar to the 1260 Series and describes theswitching module in relation to the Master. Thisaddress corresponds to the binary value of the switchsetting of SW1 on the switching module PCB.

The range of values for <channel> is:

One-wire 00-96Two-wire 00-95Four-wire 00-47

The actual mapping of number to connector pins is given in Table3-1. Figure 3-1 shows the physical location of the variousconnector pins.

Page 23: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Module Specific Syntax 3-2

Example:

OPEN 3.02

This open command will open channel 2 on the module at switchcard address 3

CLOSE Command The Module Specific Syntax for the CLOSE command is the sameas for the OPEN command.

PSETUPCommand

The PSETUP command causes the specified module setup to betransmitted to the VXI Controller. The syntax used is:

PSETUP <module address>[;<module address>] [;<moduleaddress>] where <module address> is the address.

The responses to the PSETUP command for the 1260-35Multiplexer/Scanner is as follows:

1260-35: Two-wire

<module address>. 1260-35B, Two-wire Scanner/Multiplexer Module<module address>. BBM<module address>.END

1260-35: Four-wire

<module address>. 1260-35A, Four-wire Scanner/Multiplexer Module<module address>. BBM<module address>.END

The response to the PSETUP command consists of a header onthe first line. The header describes the model number followed byan A or B designating four or two-wire, respectively. The next linedesignates the setup mode for scanning which, by default, isBreak-Before-Make (BBM). The last line containing the "END"characters denotes no more information to report.

PDATAOUT The PDATAOUT command causes the specified module totransmit the CLOSED state of the relays within the switching

Page 24: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Module Specific Syntax 3-3

Command module to the 1260 Controller. The syntax used is:

PDATAOUT <module address>[.<module address>] [;<module address>]…..

The responses to the PDATAOUT command is as follows:

1260-35: Two-wire

<module address>. 1260-3 SB Two-wire Scanner/Multiplexer Module <module address>. <channel>[,<channel>] [,<channel>] <module address>.END

1260-35 Four-wire

<module address>. 1 260-35A Four-wire Scanner/Multiplexer Module<module address>. <channel>[,<channel>] [,<channel>]<module address>.END

The response to the PDATAOUT command consists of a headeron the first line as with the PSETUP response. The next linedetails the channels currently closed on the module and is blankwhen no channels are closed. Again, the last line is denoted by the"END" string of characters.

Operation InSingle-Wire Mode

The 1260-35 is delivered with all jumpers installed (refer to Table2-1). In this configuration, the module is a 1 x 96 two-wiremultiplexer (refer to Figure 3-1).

Channel 97 is a single pole, double throw (SPDT) relay with itscommon channel connected to J202, pin B2. The normally closed(NC) contact is connected to the "LO" side of the two-wirecommon bus, and the normally open (NO) contact is connected tothe "HI" side of the common bus.

The common output of channel 96 is the single channel of the 192x 1 multiplexer, and the 96 HI and 96 LO connections make up the192 channels. By closing the appropriate channel (0-95) andopening or closing channel 96. a 192 x 1 multiplexer is achieved.

Example:

CLOSE 3.46CLOSE 3.96

This would correct J202 pin B2 to J202 pin A4

Table 3-1, 1260-35 Channel Closure

Page 25: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Module Specific Syntax 3-4

channel interconnect for 1, 2 and 4-wire modes.

1-wire mode:

<channel> <channel> output <channel> input(channel 96 open)0 thru 95 always J202- B2 (see 2-wire mode channels 0-95 input pins b-side of channel)(channel 96 closed)0 thru 95 always J202- B2 (see 2-wire mode channels 0-95 input pins a-side of channel)Thus, a one 1 x 191 1-wire mode is acheived.

2-wire mode:channel> <channel> output pins to <channel> input pins

a / b a / b(HI) (Lo) (HI) (LO)

0 J200- A30 / B30 J200- A29 / B291 J200- A30 / B30 J200- A28 / B282 J200- A30 / B30 J200- A27 / B273 J200- A30 / B30 J200- A26 / B264 J200- A30 / B30 J200- A25 / B255 J200- A30 / B30 J200- A24 / B246 J200- A23 / B23 J200- A22 / B227 J200- A23 / B23 J200- A21 / B218 J200- A23 / B23 J200- A20 / B209 J200- A23 / B23 J200- A19 / B1910 J200- A23 / B23 J200- A18 / B1811 J200- A23 / B23 J200- A17 / B1712 J200- A16 / B16 J200- A15 / B1513 J200- A16 / B16 J200- A14 / B1414 J200- A16 / B16 J200- A13 / B1315 J200- A16 / B16 J200- A12 / B1216 J200- A16 / B16 J200- A11 / B1117 J200- A16 / B16 J200- A10 / B1018 J200- A9 / B9 J200- A8 / B819 J200- A9 / B9 J200- A7 / B720 J200- A9 / B9 J200- A6 / B621 J200- A9 / B9 J200- A5 / B522 J200- A9 / B9 J200- A4 / B423 J200- A9 / B9 J200- A3 / B324 J202- A30 / B30 J202- A29 / B2925 J202- A30 / B30 J202- A28 / B2826 J202- A30 / B30 J202- A27 / B2727 J202- A30 / B30 J202- A26 / B2628 J202- A30 / B30 J202- A25 / B2529 J202- A30 / B30 J202- A24 / B24

Page 26: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Module Specific Syntax 3-5

Table 3-1, 1260-35 Channel Closure (continued)

30 J202 A23 I B23 J202 A22 / B2231 J202 A23 / B23 J202 A21 / B2132 J202 A23 / B23 J202 A20 / B2033 J202 A23 / B23 J202 A19 / B1934 J202 A23 / B23 J202 A18 / B1835 J202 A23 / B23 J202 A17 / B1736 J202 A16 / B16 J202 A15 / B1537 J202 A16 / B16 J202 A14 / B1438 J202 A16 / B16 J202 A13 / B1339 J202 A16 / B16 J202 A12 / B1240 J202 A16 / B16 J202 A11 / B1141 J202 A16 / B16 J202 A10 / B1042 J202 A9 / B9 J202 A8 / B843 J202 A9 / B9 J202 A7 / B744 J202 A9 / B9 J202 A6 / B645 J202 A9 / B9 J202 AS / B546 J202 A9 / B9 J202 A4 / B447 J202 A9 / B9 J202 A3 / B348 J201 A30 / B30 J201 A29 / B2949 J201 A30 / B30 J201 A28 / B2850 J201 A30 / B30 J201 A27 / B2751 J201 A30 / B30 J201 A26 / B2652 J201 A30 / B30 J201 A25 / B2553 J201 A30 / B30 J201 A24 / B2454 J201 A23 / B23 J201 A22 / B2255 J201 A23 / B23 J201 A21 / B2156 J201 A23 / B23 J201 A20 / B2057 J201 A23 / B23 J201 A19 / B1958 J201 A23 / B23 J201 A18 / B1859 J201 A23 / B23 J201 A17 / B1760 J201 A16 / B16 J201 A15 / B1561 J201 A16 / B16 J201 A14 / B1462 J201 A16 / B16 J201 A13 / B1363 J201 A16 / B16 J201 A12 / B1264 J201 A16 / B16 J201 A11 / B1165 J201 A16 / B16 J201 A10 / B1066 J201 A9 / B9 J201 A8 / B867 J201 A9 / B9 J201 A7 / B768 J201 A9 / B9 J201 A6 / B669 J201 A9 / B9 J201 AS / B570 J201 A9 / B9 J201 A4 / B471 J201 A9 / B9 J201 A3 / B372 J203 A30 / B30 J203 A29 / B2973 J203 A30 / B30 J203 A28 / B2874 J203 A30 / B30 J203 A27 / B2775 J203 A30 / B30 J203 A26 / B2676 J203 A30 / B30 J203 A25 / B2577 J203 A30 / B30 J203 A24 / B324

Page 27: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Module Specific Syntax 3-6

Table 3-1, 1260-35 Channel Closure (continued)

78 J203 A23 / B23 J203 A22 / B2279 J203 A23 / B23 J203 A21 / B2180 J203 A23 / B23 J203 A20 / B2081 J203 A23 / B23 J203 A19 / B1982 J203 A23 / B23 J203 A18 / B1883 J203 A23 / B23 J203 A17 / B1784 J203 A16 / B16 J203 A15 / B1585 J203 A16 / B16 J203 A14 / B1486 J203 A16 / B16 J203 A13 / B1387 J203 A16 / B16 J203 A12 / B1288 J203 A16 / B16 J203 A11 / B1189 J203 A16 / B16 J203 A10 / B1090 J203 A9 / B9 J203 A8 / B891 J203 A9 / B9 J203 A7 / B792 J203 A9 / B9 J203 A6 / B693 J203 A9 / B9 J203 A5 / B594 J203 A9 / B9 J203 A4 / B495 J203 A9 / B9 J203 A3 / B3

96 (not used in 2-wire mode)

4-wire mode:

<channel> refer to the following 2-wirechannels for the input/outputpins

<channel> refer to the following 2-wire channels for theinput/output pins

0 0,48 24 24,721 1,49 25 25,732 2,50 26 26,743 3,51 27 27,754 4, 52 28 28,765 5,53 29 29,776 6, 54 30 30,787 7,55 31 31,798 8,56 32 32,809 9 , 57 33 33,8110 10, 58 34 34,8211 11,59 35 35,8312 12,60 36 36,8413 13,61 37 37,8514 14,62 38 38,8615 15,63 39 39,8716 16, 64 40 40,8817 17,65 41 41,8918 18,66 42 42,9019 19,67 43 43,9120 20,68 44 44,9221 21,69 45 45,9322 22,70 46 46,9423 23,71 47 47,95

96 (not used in 4-wire mode)

Page 28: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Module Specific Syntax 3-7Figure 3-1, 1260-35 Block Diagram

K 1 2C

H11

K 1 1C

H10

K 1 0C

H9

K 9C

H8

K 8C

H7

K 7C

H6

K 1 3C

H12

K 1 4C

H13

K 1 5C

H14

K 1 6C

H15

K 1 7C

H16

K 1 8C

H17

K 3 6C

H35

K 3 5C

H34

K 3 4C

H33

K 3 3C

H32

K 3 2C

H31

K 3 1C

H30

K 3 7C

H36

K 3 8C

H37

K 3 9C

H38

K 4 0C

H39

K 4 1C

H40

K 4 2C

H41

K 6 0C

H59

K 5 9C

H58

K 5 8C

H57

K 5 7C

H56

K 5 6C

H55

K 5 5C

H54

K 6 1C

H60

K 6 2C

H61

K 6 3C

H62

CH

63K 6 4 K 6 5

CH

64

K 6 6C

H65

K 8 4C

H83

K 8 3C

H82

K 8 2C

H81

K 8 1C

H80

K 8 0C

H79

K 7 9C

H78

K 8 5C

H84

K 8 6C

H85

K 8 7C

H86

CH

87K 8 8 K 8 9

CH

88

K 9 0C

H89

K 6C

H5

K 5C

H4

KK 4C

H3

KK 3C

H2

K 2C

H1

K 1C

H0

K 1 9C

H18

K 2 0C

H19

K 2 1C

H20

CH

21K 2 2 K 2 31

CH

22

K 2 4C

H23

K 3 0C

H29

K 2 9C

H28

KK 2 8C

H27

KK 2 7C

H26

K 2 6C

H25

K 2 5C

H24

K 4 3C

H42

K 4 4C

H43

K 4 5C

H44

CH

45K 4 6 K 4 7

CH

46

K 4 8C

H47

K 5 4C

H53

K 5 3C

H52

KK 5 2C

H51

KK 5 1C

H50

K 5 0C

H49

K 4 9C

H48

K 6 7C

H66

K 6 8C

H67

K 6 9C

H68

CH

69K 7 0 K 7 1

CH

70

K 7 2C

H71

K 7 8C

H77

K 7 7C

H76

KC

H75

K 7 6 KC

H74

K 7 5 K 7 4C

H73

K 7 3C

H72

K 9 1C

H90

K 9 2C

H91

K 9 3C

H92

CH

93K 9 4 K 9 5

CH

94

K 9 6C

H95

W4A

W4B

W9A

W9B

W13

B

W18

A

W18

B

1/24

CO

M 2

CO

M 3

CO

M 6

CO

M 7

1/24

W7A

W7B

1/96

CO

M 1

0C

OM

11

1/24

W15

A

W15

B

1/96

CO

M 1

4C

OM

15

1/24

W3A

W3B

W5B

W5A

W2B

W2A

1/12

1/12

ANAL

OG

BUS 1

W6B

W6A

1/48

W8A

W8B

W10

B

W10

A

1/12

1/12

W11

B

W11

A

K97

CO

M 1

71-

WIR

EC

H96

ANAL

OG

BUS 2

W20

B

W20

A

W12

A

W12

B W14

B

W14

A

1/12

1/12

W16

B

W16

A

W17

AW

19B

W17

BW

19A

1/12

1/12

1/48

AB

US

1C

OM

1C

OM

4C

OM

5C

OM

8A

BU

S 2

CO

M 9

CO

M 1

2C

OM

13

CO

M 1

6

W13

A

Page 29: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Module Specific Syntax 3-8

Figure 3-2, 1260-35 Pin Connections, Front View

Page 30: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-1

Chapter 4

DRAWINGS

404944 Final Assy, 1260-35 (IDC Connectors) ...................................................4-3

404944-001 Final Assy, 1260-35A (Crimp Connectors) .............................................4-4

401989 PCB Assy, 1260-35..................................................................................4-5

431989 Schematic, 1260-35..................................................................................4-7

401992 PCB Assy, 1260-35D.............................................................................4-24

431992 Schematic, 1260-35D.............................................................................4-25

Page 31: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-2

Page 32: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-3

NO

TES:

DRA

FT

T.D

AVI

S

F

12

45

67

8

12

3

4049

44

404944

RELE

ASE

D P

ER D

RN N

O. 1

338

1/1

G

45

6

PRO

PRIE

TARY

NO

TICE

TITLE

SIZE

CA

GE

CO

DE

78

3

H G

G

1

F E D C B A

H G F E D C B

REVI

SIO

NS

THIS

DO

CUM

ENT

AN

D T

HE T

ECHN

ICAL

DAT

A HE

REIN

DIS

CLO

SED

ARE

PRO

PRIE

TARY

TO

RAC

AL IN

STRU

-M

ENTS

IN

C.

AND

SHA

LL N

OT,

WITH

OUT

THE

EX-

PRES

S W

RITT

EN P

ERM

ISSI

ON

OF

RAC

AL IN

STRU

-M

ENTS

INC

. BE

USED

, REL

EASE

D O

R D

ISC

LOSE

D IN

WHO

LE O

R IN

PAR

T, O

R US

ED T

O S

OLIC

IT Q

UOTA

-TIO

NS

FRO

M A

CO

MPE

TITIV

E SO

URC

E O

R US

ED F

OR

MAN

UFAC

TURE

BY

AN

YON

E O

THER

THA

N R

ACAL

IN-

STRU

MEN

TS IN

C. T

HE I

NFO

RMAT

ION

HER

EON

HAS

BEEN

DEV

ELO

PED

AT

PRIV

ATE

EXP

ENSE

, AN

D M

AYO

NLY

BE

USE

D F

OR

PUR

POSE

S O

F E

NG

INEE

RIN

GEV

ALUA

TION

AN

D F

OR

INC

ORP

ORA

TION

INTO

TEC

H-N

ICAL

SPE

CIF

ICAT

ION

S A

ND

OTH

ER D

OC

UMEN

TSW

HIC

H S

PEC

IFY

PRO

CUR

EMEN

T O

F PR

OD

UCTS

FRO

MRA

CAL

INST

RUM

ENTS

INC

.

Rac

al I

nstru

me

nts,

Inc

.4

Go

od

yea

r St.,

Irvin

e,C

A.9

2718

-200

2

REV

.D

OC

UM

ENT

NU

MBE

R

SHT.

OF

SCA

LEC

ALC

.WT

ACT.W

T

2179

32

DES

CRI

PTIO

ND

ATE

APP

ROVE

DRE

V.

D

DOC.NO.

A B C D E

REVI

SED

PER

EO

NO

. 208

09J.

ROBI

NSO

N

9-26

-90

REVI

SED

PER

EO

NO

. 208

72

9405

05

9405

05J.

ROBI

NSO

N

REVI

SED

PER

EO

NO

.

J.RO

BIN

SON

J.RO

BIN

SON

J.RO

BIN

SON

REVI

SED

PER

EO

NO

. 221

69

REVI

SED

PER

EO

NO

. 227

66

9405

05

9405

05

9405

05

AUS

MA

N

AUS

MA

N

AUS

MA

N

AUS

MA

N

AUS

MA

N

1260

-35,

2W, 1

X96

SC

MUX

,IDC

REVI

SED

& R

EDRA

WN

PER

EO

NO

. 230

43

SL95

0209

AUS

MA

N

PART

OF

ITEM

17

DO

NO

T SH

IP O

R ST

ORE

NEA

R ST

RON

G

ELEC

TRO

STA

TIC ,

ELEC

TRO

MA

GN

ETIC

,M

AG

NET

IC O

R R

AD

IOA

CTIV

E FI

ELD

S

REF

16 15 319

A/R

SCAL

E: 2

/1

REF

REF

2 RE

QD9

HAN

DLE

PAR

T O

F ITE

M 1

6 (TO

P)ITE

M 1

5 (B

OT) FL

AT H

EAD

SC

REW

,PA

RT O

F ITE

M 1

7 AP

PLY

LOC

TITE

"TO

P"

"BO

TTO

M"

PLAT

E, P

ART

OF

ITEM

S 15

, 16

17 17

MO

UNTIN

G B

LOC

KPA

RT O

F ITE

MS

15, 1

6

1

0

8

1

21

LABE

L, P

ART

OF

ITEM

31

RAC

AL IN

STRU

MEN

TS L

OG

O (T

OP)

VXI S

YMBO

L (B

OT)

31

765432

LOGICAL ADDRESS SELECT

1

MSB

LSB

1

0

4321

INTERRUPT SELECT

LSB

MSB

N/A

A/R

BEAR

ING

, PAR

TO

F ITE

MS

15, 1

6

1

5.

27

11 13

2 RE

QD

24

REF

27

111.

00 ±

.12

1

296.

1.00

±.1

2

2.

PART

OF

ITEM

35

.70

±.1

2

31 2 4 5 6

4. C

ON

NEC

T C

ABL

E FR

OM

ITEM

1 T

O IT

EM 3

AS

SHO

WN

. 5.

APP

LY L

OC

TITE

SPA

RIN

GLY

. D

O N

OT

ALL

OW

CO

NTA

CT

WITH

EJE

CTO

R H

AN

DLE

S ITE

MS

1

5 (B

OT)

AN

D 1

6(TO

P).

6. L

OC

ATE

APP

ROPR

IATE

VXI

LA

BEL

WH

ERE

SHO

WN

.

REF

EREN

CE

9214

10 F

OR

SPEC

IFIC

LA

BEL

IN

FORM

ATIO

N.

2 3 4 OPEN

CLOSE

5 6

12 LOCAL BUS LINES

2.

REF

13 24

1

0

6 5 4 3

3 RE

QD

2 1

LSB MSB

(Configurable cards only)

1260 CARD ADDR

8421ID

BYTE

PART

OF

ITEM

35

4.

196

REQ

D3

19

2334

6

BB

1. D

ISC

ARD

UN

USED

HA

RDW

ARE

IN IT

EM 1

7. 2.

AFF

IX L

ABE

LS A

S SH

OW

N, A

LIG

N L

ABE

L TE

XT

WITH

APP

ROPR

IATE

SW

ITCH

AC

TUA

TORS

. 3.

IN

CLU

DE

SHIP

PIN

G K

IT, IT

EM 5

IN B

OX

WITH

ASS

Y.

DET

AIL

'A'

DET

AIL

'A'

24

SCAL

E: 1

/2BO

TTO

M V

IEW

VIEW

B-B

Page 33: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-4

NO

TES:

DRA

FT

T.D

AVI

S

12

45

67

8

12

3

1/1

4049

44-0

01

404944-001

RELE

ASE

D P

ER D

RN N

O. 1

491

45

6

PRO

PRIE

TARY

NO

TICE

TITLE

SIZE

CA

GE

CO

DE

78

3

H G

E

1

F E D C B A

H G F E D C B

REVI

SIO

NS

THIS

DO

CUM

ENT

AN

D T

HE

TEC

HN

ICA

L D

ATA

HER

EIN

DIS

CLO

SED

ARE

PRO

PRIE

TARY

TO

RA

CA

L IN

STRU

-M

ENTS

IN

C.

AN

D S

HA

LL N

OT,

WITH

OUT

TH

E EX

-PR

ESS

WRI

TTEN

PER

MIS

SIO

N O

F RA

CA

L IN

STRU

-M

ENTS

INC

. BE

USED

, REL

EASE

D O

R D

ISC

LOSE

D IN

WH

OLE

OR

IN P

ART

, OR

USED

TO

SO

LIC

IT Q

UOTA

-TIO

NS

FRO

M A

CO

MPE

TITIV

E SO

URC

E O

R US

ED F

OR

MA

NUF

AC

TURE

BY

AN

YON

E O

THER

TH

AN

RA

CA

L IN

-ST

RUM

ENTS

INC

. TH

E IN

FORM

ATIO

N H

EREO

N H

AS

BEEN

DEV

ELO

PED

AT

PRIV

ATE

EXP

ENSE

, AN

D M

AY

ON

LY B

E U

SED

FO

R P

URPO

SES

OF

EN

GIN

EERI

NG

EVA

LUA

TION

AN

D F

OR

INC

ORP

ORA

TION

INTO

TEC

H-

NIC

AL

SPE

CIF

ICA

TION

S A

ND

OTH

ER D

OC

UMEN

TSW

HIC

H S

PEC

IFY

PRO

CUR

EMEN

T O

F PR

OD

UCTS

FRO

MRA

CA

L IN

STRU

MEN

TS IN

C.

Rac

al I

nstru

me

nts,

Inc

.4

Go

od

yea

r St.,

Irvin

e,C

A.9

2718

-200

2

REV

.D

OC

UM

ENT

NU

MBE

R

SHT.

OF

SCA

LEC

ALC

.WT

ACT.W

T

2179

32

DES

CRI

PTIO

ND

ATE

APP

ROVE

DRE

V.

D

DOC.NO.

A B C

REVI

SED

PER

EO

NO

. 223

74

D E

REVI

SED

PER

EO

NO

.

J.RO

BIN

SON

10-1

6-91

Z.H

.B94

0126

9405

06

REVI

SED

PER

EO

NO

.

REVI

SED

PER

EO

NO

. 227

67

REVI

SED

PER

EO

NO

.

J.RO

BIN

SON

9405

06RE

VISE

D &

RED

RAW

N P

ER E

O N

O. 2

3045

SL

950

209

AUS

MA

N

J.R.

AUS

MA

N

1260

-35A

,2W

,1X

96 S

C M

UX,C

RMP

AUS

MA

N

PART

OF

ITEM

17

DO

NO

T SH

IP O

R ST

ORE

NEA

R ST

RON

GEL

ECTR

OST

ATIC

, EL

ECTR

OM

AG

NET

IC,

MA

GN

ETIC

OR

RA

DIO

AC

TIVE

FIEL

DS

REF

16 15 319

A/R

SCAL

E: 2

/1

REF

REF

2 RE

QD9

HAN

DLE

PAR

T O

F ITE

M 1

6 (TO

P)ITE

M 1

5 (B

OT) FL

AT H

EAD

SC

REW

,PA

RT O

F ITE

M 1

7 AP

PLY

LOC

TITE

"TO

P"

"BO

TTO

M"

PLAT

E, P

ART

OF

ITEM

S 15

, 16

17 17

MO

UNTIN

G B

LOC

KPA

RT O

F ITE

MS

15, 1

6

1

0

8

1

21

LABE

L, P

ART

OF

ITEM

31

RAC

AL IN

STRU

MEN

TS L

OG

O (T

OP)

VXI S

YMBO

L (B

OT)

31

765432

LOGICAL ADDRESS SELECT

1

MSB

LSB

1

0

4321

INTERRUPT SELECT

LSB

MSB

N/A

A/R

BEAR

ING

, PAR

TO

F ITE

MS

15, 1

6

1

5.

27

11 13

2 RE

QD

24

REF

27

111.

00 ±

.12

296.

1.00

±.1

2

2.

PART

OF

ITEM

35

.70

±.1

2

31 2 4 5

4. C

ON

NEC

T C

ABLE

FRO

M IT

EM 1

TO

ITEM

3 A

S SH

OW

N.

5. A

PPLY

LO

CTIT

E SP

ARIN

GLY

. D

O N

OT

ALLO

W

C

ON

TAC

T W

ITH E

JEC

TOR

HAN

DLE

S ITE

MS

1

5 (B

OT)

AN

D 1

6(TO

P).

6. L

OC

ATE

APPR

OPR

IATE

VXI

LAB

EL W

HERE

SHO

WN

.

REF

EREN

CE

9214

10 F

OR

SPEC

IFIC

LAB

EL

INFO

RMAT

ION

.

6 1 2 3 4 OPEN

CLOSE

5 6

12 LOCAL BUS LINES

2.

REF

13 24

1

0

6 5 4 3

3 RE

QD

2 1

LSB MSB

(Configurable cards only)

1260 CARD ADDR

8421ID

BYTE

PART

OF

ITEM

35

4.

196

REQ

D3

19

2334

7

BB

1. D

ISC

ARD

UN

USED

HAR

DW

ARE

IN IT

EM 1

7. 2.

AFF

IX L

ABEL

S AS

SHO

WN

, ALIG

N L

ABEL

TEX

T

WITH

APP

ROPR

IATE

SW

ITCH

ACTU

ATO

RS.

3. I

NC

LUD

E SH

IPPI

NG

KIT,

ITEM

5 IN

BO

X W

ITH A

SSY.

DET

AIL

'A'

DET

AIL

'A'

24

SCAL

E: 1

/2BO

TTO

M V

IEW

VIEW

B-B

Page 34: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-5

Page 35: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-6

Page 36: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-7

Page 37: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-8

Page 38: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-9

Page 39: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-10

Page 40: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-11

Page 41: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-12

Page 42: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-13

Page 43: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-14

Page 44: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-15

Page 45: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-16

Page 46: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-17

Page 47: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-18

Page 48: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-19

Page 49: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-20

Page 50: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-21

Page 51: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-22

Page 52: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-23

Page 53: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-24

Page 54: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-25

Page 55: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-26

Page 56: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-27

Page 57: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-28

Page 58: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-29

Page 59: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Drawings 4-30

Page 60: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Parts List 5-1

Chapter 5

PARTS LIST

404944 Final Assembly, 1260-35 (IDC Connector) 5-3

404975 Shipping Kit, 1260-35 5-4

404944-001 Final Assembly, 1260-35A (Crimp Connectors) 5-5

404975-001 Shipping Kit, 1260-35A 5-6

401989 PCB Assy, 1260-35 5-7

401992 PCB Assy, 1260-35D 5-10

List of Suppliers 5-11

Page 61: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Parts List 5-2

This page was left intentionally blank.

Page 62: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Parts List 5-3

Page 63: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Parts List 5-4

Page 64: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Parts List 5-5

Page 65: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Parts List 5-6

Page 66: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Parts List 5-7

Page 67: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Parts List 5-8

Page 68: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Parts List 5-9

Page 69: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Parts List 5-10

Page 70: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Parts List 5-11

Page 71: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Parts List 5-12

This page was left intentionally blank.

Page 72: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-1

Chapter 6

OPTIONAL HARNESS ASSEMBLIES

The following harness assemblies are used to connect Racal Instruments Model 1260-35 toFreedom Series Test Receiver Interfaces.

Each harness documentation consists of an assembly drawing, parts list, system wire list and wirelist.

407280 Virginia Panel, Inc. Series VP90 Interface Harness

407281 TTI Testron, Inc. Interface Harness

For more information on Racal Instruments complete line of Test Receivers Interface solution,contact your Sales Representative.

Page 73: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-2

This page was left intentionally blank.

Page 74: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-3

6

1.7

MA

X3

PLC

S

AR

6 PL

CS

11.0

±1.

0 2

PLC

S

39.0

±2.

0 3

PLC

S

6 7

3

7

109AR

10 P

LCS

23

PLC

S

PIN

1

2.5

±.2

2.0

±.2

PIN

1

PIN

1

3

AR2.

.2

3 RE

QD

4072

80 R

EV.

2.5

±.2

36.0

±2.

0

7

SEE

WIR

E LI

ST F

OR

CO

NTA

CT

ASS

IGN

MEN

TS A

ND

CO

NN

ECTIO

NS.

2 3 6 7 85.M

ATIN

G IT

A C

ON

NEC

TOR

FOR

J102

IS V

IRG

INIA

PA

NEL

P/N

510

108

101.

USE

ITA

PIN

P/N

610

110

108

.

MA

TING

ITA

CO

NN

ECTO

R FO

RJ1

00 A

ND

J10

1 IS

VIR

GIN

IAPA

NEL

P/N

510

108

126

. USE

ITA P

IN P

/N 6

10 1

10 1

08.

1

INK

STA

MP

"J--

-" A

PPRO

XI-

MA

TELY

WH

ERE

SHO

WN

.

APP

LY P

ROTE

CTIV

E C

OA

TING

(ITEM

5) O

VER

MA

RKIN

G.

1. 4.

PLA

CE

APP

ROPR

IATE

SIZ

E C

LEA

RSH

RIN

K TU

BIN

G O

VER

MA

RKIN

G.

TERM

INA

TE B

RAID

ED S

LEEV

ING

(ITEM

6) A

T IN

DIC

ATE

D E

ND

SW

ITH B

LAC

K SH

RIN

K TU

BIN

G.

PLA

CE

SHRI

NK

TUBI

NG

(ITEM

8)

APP

ROXI

MA

TELY

WH

ERE

SHO

WN

.

2

2

3 4

PLC

SFA

R SI

DE

PIN

1

2

9.EN

CLO

SE C

ABL

ES IN

SIN

GLE

BA

G.

PIN

1

MA

RK "4

0728

0" A

ND

LA

TEST

REVI

SIO

N O

N A

PPRO

PRIA

TESI

ZE S

HRI

NK

TUBI

NG

APP

ROXI

-M

ATE

LY W

HER

E SH

OW

N.

PIN

1

PIN

1

8

4A

R

8

J1

J2

(P2)

J102 (P2)

J1

J2J3

J1

J3

J100

J101

J2

(P2)

(P2)

J200

J203

(P3)

(P1)

J202

J201

(P1)

(P1)

(P1)

P2

DWG

NO

.RE

V.

SCAL

ESH

EET

OF

ACT.W

TC

ALC

.WT

PRO

PRIE

TARY

NO

TICE

SIZE

REV

DES

CRIP

TIO

ND

ATE

1

APP

RO

VED

REV

ISIO

NS

AM

N 0

4/12

/99

NO

TES:

A B

ZON

E

CD

REV

ISED

PER

EO

NO

. 2

53

46

REV

ISED

PER

EO

NO

. 2

57

59

db

SEE

SEPA

RATE

PA

RTS

LIST

TITLE

4 G

oo

dye

ar S

t.,Irv

ine

,CA

.927

18-2

002

A

D ABC

12

34

13

4072

80

AM

S 11

/17/

94

11

-08

-94

4

CAG

E C

ODE

NO

NE

REL

EASE

D P

ER D

RN

NO

. 1

54

1

THIS

DO

CU

MEN

T A

ND

TH

E TE

CH

NIC

AL

DA

TA H

EREO

N D

ISC

LOSE

D A

RE

PRO

PRIE

TARY

TO R

AC

AL

INST

RU

MEN

TS IN

C. A

ND

SH

ALL

NO

T, W

ITH

OU

T TH

E EX

PRES

S W

RIT

TEN

PERM

ISSI

ON

O

F RA

CA

L IN

STRU

MEN

TS IN

C. B

E U

SED

, R

ELEA

SED

OR D

ISC

LOSE

DIN

WH

OLE

OR IN

PA

RT,

O

R U

SED

TO

SO

LIC

IT Q

UO

TATI

ON

FRO

M A

CO

MPE

TITI

VE

SOU

RC

E O

R U

SED

FO

R M

AN

UFA

CTU

RE

BY A

NYO

NE

OTH

ER T

HA

N RA

CA

L IN

STRU

MEN

TSIN

C. TH

E IN

FORM

ATI

ON

H

EREO

N H

AS

BEEN

DEV

ELO

PED

A

T PR

IVA

TE E

XPE

NSE

,A

ND

M

AY

ON

LY B

E U

SED

FO

R P

URPO

SES

OF

ENG

INEE

RIN

G EV

ALU

ATI

ON

A

ND

FO

RIN

CO

RPO

RA

TIO

N IN

TO T

ECH

NIC

AL

SPEC

IFIC

ATI

ON

S A

ND

OTH

ER D

OC

UM

ENTS

W

HIC

HSP

ECIF

Y P

RO

CU

REM

ENT

OF

PRO

DU

CTS

FRO

M R

AC

AL

INST

RU

MEN

TS IN

C.

12

98

03

37

REV

. F

DWG. NO. REV.SH.

8

HA

RNES

S A

SSY,

1260

-35,

VP90

D407280

D

REV

ISED

PER

EO

NO

. 2

34

32

& R

EDRW

N

C D

98

04

29

J. R

OBI

NSO

N

LA 1

1-1

7-9

4

J. R

OBI

NSO

N

Page 75: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-4

RACAL INSTRUMENTS INC.

Assembly 407280 HARNESS ASSY, 1260-35, VP90 Date 3/18/99 Revision D

# Component Description U/N Qty Reqd Ref1 405084 PCB ASSY, VP90 INTFC, 64CONTCT EA 1.000002 405085 PCB ASSY, VP90 INTFC, 96CONTCT EA 2.000003 407259 CABLE ASSY, IDC, 64COND,VP90 EA 3.000004 407258 CABLE ASSY, IDC, 64SPLT,VP90 EA 1.000005 910541 POLYURETHANE CONFORMAL COAT EA .000016 GRP-l10-l/2 TBGWOV- POY. 250ID-BLACK FT .000017 500005 TIE CORD NYLON FT .000018 500017 TBGSRK- POF. 500lD-BLACK FT .000019 M23053/5-109-4 TBGSRK- POF. 750ID-YELLOW FT .0000110 500104 TBGSRK- POF .750 ID-CLEAR FT .00001

Page 76: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-5

Page 77: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-6

Page 78: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-7

Page 79: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-8

Page 80: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-9

Page 81: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-10

Page 82: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-11

Page 83: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-12

9803

40 R

EV. F

DW

G N

O.

REV.

SCA

LESH

EET

OF

AC

T.W

TC

ALC

.WT

1

11

PRO

PRIE

TARY

NO

TICE

SIZE

DW

G. N

O.

SH REV

DES

CRI

PTIO

ND

ATE

APP

ROVE

D

REVI

SIO

NS

NO

TES:

REV.

ZON

E

REVI

SED

PER

EO

NO

.

D

4072

81

C

D

ARE

LEA

SED

PER

DRN

NO

. 154

111

/8/9

4D

B

BJR

95-

03-1

3TD

E

CRE

VISE

D P

ER E

O N

O. 2

5356

JR

9805

01

AB

12

34

1

1:1

34

C

HA

RNES

S A

SSY,

126

0-35

, TTI

AB

TITLE

4 G

oo

dye

ar S

t.,Irv

ine

,CA

.927

18-2

002

CA

GE

CO

DE

THIS

DO

CU

MEN

T A

ND

TH

E TE

CH

NIC

AL

DA

TA H

EREO

N D

ISC

LOSE

D A

RE

PRO

PRIE

TARY

TO R

AC

AL

INST

RU

MEN

TS IN

C. A

ND

SH

ALL

NO

T, W

ITH

OU

T TH

E EX

PRES

S W

RIT

TEN

PERM

ISSI

ON

O

F RA

CA

L IN

STRU

MEN

TS IN

C. B

E U

SED

, R

ELEA

SED

OR D

ISC

LOSE

DIN

WH

OLE

OR IN

PA

RT,

O

R U

SED

TO

SO

LIC

IT Q

UO

TATI

ON

FRO

M A

CO

MPE

TITI

VE

SOU

RC

E O

R U

SED

FO

R M

AN

UFA

CTU

RE

BY A

NYO

NE

OTH

ER T

HA

N RA

CA

L IN

STRU

MEN

TSIN

C. TH

E IN

FORM

ATI

ON

H

EREO

N H

AS

BEEN

DEV

ELO

PED

A

T PR

IVA

TE E

XPE

NSE

,A

ND

M

AY

ON

LY B

E U

SED

FO

R P

URPO

SES

OF

ENG

INEE

RIN

G EV

ALU

ATI

ON

A

ND

FO

RIN

CO

RPO

RA

TIO

N IN

TO T

ECH

NIC

AL

SPEC

IFIC

ATI

ON

S A

ND

OTH

ER D

OC

UM

ENTS

W

HIC

HSP

ECIF

Y P

RO

CU

REM

ENT

OF

PRO

DU

CTS

FRO

M R

AC

AL

INST

RU

MEN

TS IN

C.

C

1. C

ON

NEC

TOR

P2 T

HRU

P8

TO B

E FO

LDED

SO

TH

AT

PIN

#1

IS A

T O

NE

SID

E O

F

CA

BLE

ON

LY A

S SH

OW

N.

2 B

LAC

K IN

K M

ARK

J2-

- A

T P1

APP

ROX.

W

HER

E SH

OW

N.

3 W

HITE

INK

MA

RK J

1--

PER

TABU

LATIO

N

AT

P2 T

HRO

UGH

P8

APP

ROX.

WH

ERE

SHO

WN

.

CA

BLE

#1

IS S

HO

WN

ON

TO

P.

REVI

SED

PER

EO

NO

.236

28 &

RED

RAW

N

ROBI

NSO

N

J103

CO

NN

ECTO

RC

ABL

E #

1J2

00

P2 T

HRU

P8

(P1)

J104

J203

J100

J101

J102

J201

J202

P1

CA

BLE

#2

CA

BLE

#3

CA

BLE

#4

1

(P2)

(P3)

(P4)

(P5)

(P6)

(P7)

(P8)

J105

J106

J107

J108

J109

J110

J111

J112

J113

J114

J115

J116

J117

J118

J119

J120

J121

J122

J123

J124

J125

J126

J127

CO

NN

ECTO

R M

ARK

ING

TA

BULA

TION

10

P2

P3

P1

P4 P6

P5 P7

P8

2

1

2

4072

81

4 RE

QD

C

1

REF

EREN

CE

ON

LYC

ABL

E N

OT

FOLD

ED A

T P2

TH

RU P

83

4

4

J106

J200

A1,

B1

4 S

PRA

Y PR

OTE

CTIV

E C

OA

TING

(ITE

M 3

)

AFT

ER M

ARK

ING

. 5.

MA

TING

REC

EIVE

R BL

OC

K FO

R C

ON

NEC

TORS

P2

TH

RU P

8 IS

TTI

P/N

VG

RCB-

170.

RE

CEI

VER

BLO

CK

MA

TES

WITH

ITA

BLO

CK

P/

N V

GFC

B-17

0. 6.

EN

CLO

SE C

ABL

ES IN

SIN

GLE

BA

G A

ND

ID

ENTIF

Y W

ITH P

ART

NUM

BER

AN

D

CUR

REN

T RE

VISI

ON

.

Page 84: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-13

Page 85: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-14

Page 86: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-15

Page 87: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-16

Page 88: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-17

Page 89: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-18

Page 90: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-19

Page 91: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-20

Page 92: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-21

Page 93: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Optional Harness Assemblies 6-22

Page 94: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Product Support 7-1

Chapter 7

PRODUCT SUPPORT

Product Support Racal Instruments has a complete Service and Parts Department.If you need technical assistance or should it be necessary to returnyour product for repair or calibration, call 1-800-722-3262. If partsare required to repair the product at your facility, call 1-949-859-8999 and ask for the Parts Department.

When sending your instrument in for repair, complete the form inthe back of this manual.

For worldwide support and the office closes to your facility, refer tothe Support Offices section on the following page.

ReshipmentInstructions

Use the original packing material when returning the 1260-35 toRacal Instruments for calibration or servicing. The original shippingcrate and associated packaging material will provide thenecessary protection for safe reshipment.

If the original packing material is unavailable, contact RacalInstruments Customer Service for information.

Page 95: 1260-35 MULTIPLEXER / SCANNERmanuals.repeater-builder.com/te-files/RACAL/RACAL 1260-35 INST.pdf · 4/10/2000  · NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax”

User Manual 1260-35

Product Support 7-2

Support OfficesRacal Instruments, Inc.4 Goodyear St., Irvine, CA 92618-2002Tel: (800) 722-3262, FAX: (949) 859-7309

Racal Instruments, Ltd.480 Bath Road, Slough, Berkshire, SL1 6BE, United KingdomTel: +44 (0) 8706 080134; FAX: +44 (0) 1753 791290

Racal Systems Electronique S.A.18 Avenue Dutartre, 78150 LeChesnay, FranceTel: +33 (1) 3923 2222; FAX: +33 (1) 3923 2225

Racal Systems Elettronica s.r.l.Strada 2-Palazzo C4, 20090 Milanofiori Assago, Milan, ItalyTel: +39 (02) 5750 1796; FAX +39 (02) 5750 1828

Racal Elektronik System GmbH.Frankenforster Strasse 21, 51427 Bergisch Gladbach, GermanyTel:+49 2204 92220; FAX: +49 2204 21491

Racal Australia Pty. Ltd.3 Powells Road, Brookvale, NSW 2100, AustraliaTel: +61 (2) 9936 7000, FAX: +61 (2) 9936 7036

Racal Electronics Pte. Ltd.26 Ayer Rajah Crescent, 04-06/07 Ayer Rajah Industrial Estate, Singapore 0513.Tel: +65 7792200, FAX: +65 7785400

Racal Instruments, Ltd.Unit 5, 25F., Mega Trade Center, No 1, Mei Wan Road, Tsuen Wan, Hong Kong, PRCTel: +852 2405 5500, FAX: +852 2416 4335