Software Upgrade

1235 - 1201 - Ceragon - IP-10G EMS SW Upgrade

Embed Size (px)

DESCRIPTION

mw

Citation preview

  • Software Upgrade

  • Agenda

    FTP Properties

    Standalone SW Download

    Standalone SW Upgrade

    Nodal IDU SW Download

    Proprietary and Confidential2

    Nodal IDU SW Download

    Nodal IDU SW Upgrade

    Rollback VS. Downgrade

  • Local FTP Server

    SW files are located on an FTP Server (local or remote)

    Configure the FTP properties to point to your local server root directory

    (Make sure RD/WR permissions are enabled)

    Proprietary and Confidential3

    EMS PC with local FTP Server installed

  • Remote FTP Server

    If you do not have an FTP Server installed locally on your PC, you may

    configure an IP address of a remote server.

    Proprietary and Confidential4

    EMS PC Remote FTP Server

  • FTP Root Directory

    Make sure you are familiar with your FTP Root Directory: this is where

    the files are stored (software versions, CFG & Unit).

    Proprietary and Confidential5

    Examples for

    SW packages

  • Configuring FTP Server Properties

    1

    Proprietary and Confidential6

    2

    1

  • Configuring FTP Server Properties

    Proprietary and Confidential7

    Type the location of the software package:

    FTP IP address

    SW folder (when relevant, in this example 66253)

    Type the username & Password(You may log in using CMD window to verify settings are correct)

  • Software Upgrade Standalone IP-10

  • Standalone SW Download

    Click on the Download button and wait till Succeeded message is

    displayed (next slide)

    Proprietary and Confidential9

    You may view at any time the download

    process by clicking on the Log Icon

  • Standalone SW Download

    Download was successfully completed, you may proceed to upgrade

    the IDU

    Proprietary and Confidential10

  • Download completed Upgrade delayed

    In case Upgrade is scheduled for later moments, the Version table will

    display the following status:

    Proprietary and Confidential11

  • Standalone Upgrade Regular

    Click on the Upgrade button. When upgrades completes successfully,

    the IDU will restart automatically.

    You may view at any time the upgrade

    Proprietary and Confidential12

    You may view at any time the upgrade

    process by clicking on the Log Icon

  • Standalone Upgrade - Timed

    Choose in Installation Type Timed option, after that you can set time

    for later scheduled upgrade

    Proprietary and Confidential13

    You can set schedule time from 1 min up

    to 1440 min (24 hour) and click to Apply

  • Standalone Upgrade Regular vs. Timed

    Click on Upgrade to start schedule timer, you can see Timer Status,

    anytime you can abort scheduled installation

    Proprietary and Confidential14

  • Software Upgrade Nodal IP-10

  • Nodal SW Download

    Important note !

    IP-10G systems with software version 3.0.34 must be upgraded to an

    Proprietary and Confidential16

    IP-10G systems with software version 3.0.34 must be upgraded to an

    officially released version while in stand-alone mode (not in shelf

    configuration) prior to a Shelf (Nodal) SW download

  • Shelf Configuration

    1. Make sure your main unit (Slot 1) is upgraded with the latest version

    2. If not, it is recommended to upgrade the main unit as a standalone IDU

    3. Verify you are familiar with the slot number(s)

    Slot 6

    Slot 5

    Proprietary and Confidential17

    Slot 4

    Slot 3

    Slot 2

    Slot 1

  • Shelf SW Download

    Configure the FTP properties if needed

    Click on the Download button and

    Proprietary and Confidential18

    Click on the Download button and

    wait till Succeeded message is

    displayed

    You may view at any time the download

    process by clicking on the Log Icon

  • Shelf SW Upgrade

    Select the target slot and then click the

    Upgrade button

    Or click Upgrade All

    Please note

    1. The number of slots depend on

    actual configuration

    Proprietary and Confidential19

    actual configuration

    2. The slot numbers are not according

    to physical allocation in the shelf

    3. Failures may occur due to wrong

    FTP configurations, unstable

    network connection or missing files

    4. IDU(s) will reset automatically upon

    successful upgrade

  • Rollback vs. Downgrade

  • Rollback VS. Downgrade

    2.8.25 2.8.31 2.8.35

    Upgrade #1 Upgrade #2

    2.8.32

    1 2

    Proprietary and Confidential21

    Downgrade

    34Rollback

    Rollback does not revert previous Downgrade operation !

    It rolls back IDU version 1 step back (prior to last Upgrade)