40
1220 S. 300 W. SLC, UT 84101 801-486-2222 ELECTRICAL ENGINEERING: EELD ELECTRICAL ENGINEERING AND LIGHTING DESIGN LLC 244 WEST 300 NORTH, STE 200 SALT LAKE CITY, UTAH 84103 801.322.2400 MECHANICAL ENGINEERING: COLVIN ENGINEERING ASSOCIATES GSBS PROJECT NO.: ISSUED DATE: 375 WEST 200 SOUTH SALT LAKE CITY, UT 84101 801.521.8600 801.521.7913 P F www.gsbsarchitects.com U OF U BLDG 73 IMPROVEMENTS PHASE 2A CONSTRUCTION DOCUMENTS 05/18/2020 2018.064.01 UNIVERSITY OF UTAH U OF U BLDG 73 IMPROVEMENTS PHASE 2A 332 SOUTH 1400 EAST SALT LAKE CITY, UT 84112 1795 EAST SOUTH CAMPUS DRIVE RM 201 SALT LAKE CITY, UT 84112 UNIVERSITY OF UTAH PROJECT No. 22363

gramoll.comgramoll.com/wp-content/uploads/2020/06/BLDG73_CD_Drawings.pdf · 1220 S. 300 W. SLC, UT 84101 801-486-2222 ELECTRICAL ENGINEERING: EELD ELECTRICAL ENGINEERING AND LIGHTING

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • 1220 S. 300 W. SLC, UT 84101

    801-486-2222

    ELECTRICAL ENGINEERING:

    EELD ELECTRICAL ENGINEERING AND

    LIGHTING DESIGN LLC

    244 WEST 300 NORTH, STE 200

    SALT LAKE CITY, UTAH 84103

    801.322.2400

    MECHANICAL ENGINEERING:

    COLVIN ENGINEERING ASSOCIATES

    GSBS PROJECT NO.:

    ISSUED DATE:

    375 WEST 200 SOUTHSALT LAKE CITY, UT 84101

    801.521.8600801.521.7913

    PF

    www.gsbsarchitects.comU OF U BLDG 73 IMPROVEMENTS PHASE 2A

    CONSTRUCTION DOCUMENTS

    05/18/2020

    2018.064.01

    UNIVERSITY OF UTAH

    U OF U BLDG 73IMPROVEMENTSPHASE 2A

    332 SOUTH 1400 EASTSALT LAKE CITY, UT 84112

    1795 EAST SOUTH CAMPUS DRIVE RM 201SALT LAKE CITY, UT 84112

    UNIVERSITY OF UTAHPROJECT No. 22363

  • OWNER PROJECT NO.:

    GSBS PROJECT NO.:

    ISSUED DATE:

    REVISIONS:

    GRAPHIC SYMBOLSABBREVIATIONS

    BLOCKING, ROUGH WOOD

    METAL (LARGE SCALE)

    QUARRY/CERAMIC TILE

    GRAVEL

    EARTH

    MATERIALS/LEGEND

    CONCRETE MASONRY UNIT

    CONCRETE (POURED IN PLACE)

    GYPSUM BOARD OR SETTING BEDS

    INSULATION (BATT & BLANKET)

    INSULATION (RIGID/SEMI-RIGID)

    CONTINUOUS ROUGH WOOD

    PLYWOOD

    FACE BRICK

    VICINITY MAP DRAWING INDEX

    375 WEST 200 SOUTHSALT LAKE CITY, UT 84101

    801.521.8600801.521.7913

    PF

    www.gsbsarchitects.com

    GRID

    GRID

    W1

    100A

    ELEVATION CONTROL POINT

    ROOM NUMBER

    SHEET WHERE ELEVATION IS DRAWN

    ELEVATION IDENTIFICATIONEXTERIOR ELEVATION SYMBOL

    SHEET WHERE SECTION IS DRAWN

    SECTION REFERENCE/WALL SECTION SYMBOL

    BUILDING SECTION SYMBOLSECTION REFERENCE/

    SHEET WHERE SECTION IS DRAWN

    DETAIL SYMBOLDETAIL NUMBER/

    SHEET WHERE DETAIL IS DRAWN

    WINDOW OR STOREFRONT NUMBER

    DOOR NUMBER

    OR DATUM POINT

    REVISION TAG

    GRID LINES

    101

    NAME

    #SHEET

    1

    SHEET

    #

    SHEET

    #

    SHEET

    #

    SHEET

    #SCALE

    VIEW NAME VIEW NUMBER/SHEET WHERE VIEW IS LOCATED

    VIEW NAME/ VIEW SCALE

    VIEW TITLE

    ROOM NAME

    SHEET WHERE ELEVATION IS DRAWN

    ELEVATION IDENTIFICATIONINTERIOR ELEVATION SYMBOL

    #SHEET

    ROOM TAG

    WINDOW TAG

    DOOR TAG

    WOOD

    COMPACTED FILL

    FIREPROOFING

    05/18/2020

    2018.064.01

    GI001

    DRAWING INDEX, SYMBOLS

    AND ABBREVIATIONS

    UNIVERSITY OF UTAH

    U OF U BLDG 73IMPROVEMENTSPHASE 2A

    332 SOUTH 1400 EASTSALT LAKE CITY, UT 84112

    1795 EAST SOUTH CAMPUS DRIVE RM 201SALT LAKE CITY, UT 84112

    PROJECT LCOATION

    SHR. SHOWER

    SIM. SIMILAR

    STC SOUND TRANSMISSIONCOEFFICIENT

    SPEC. SPECIFICATION

    STD. STANDARD

    STRUCT. STRUCTURAL

    SUPER. SUPERVISOR

    SUSP. SUSPENDED

    THRU THROUGH

    T.O. TOP OF

    T.O.A. TOP OF ASPHALT

    T.O.C. TOP OF CURB

    T.O.F. TOP OF FOOTING

    T.O.S. TOP OF SLAB OR SIDEWALK

    T.O.W. TOP OF WALL

    TYP. TYPICAL

    U.N.O. UNLESS NOTED OTHERWISE

    VEN. VENEER

    V.I.F. VERIFY IN FIELD

    VERT. VERTICAL

    VEST. VESTIBULE

    VCT VINYL COMPOSITION TILE

    WWF WELDED WIRE FABRIC

    W/ WITH

    WD. WOOD

    MTL. METAL

    MIN. MINIMUM

    MISC. MISCELLANEOUS

    N.I.C. NOT IN CONTRACT

    N.T.S. NOT TO SCALE

    # NUMBER

    NO. NUMBER

    O.C. ON CENTER

    OWSJ OPEN WEB STEEL JOIST

    OPP. OPPOSITE

    O.D. OUTSIDE DIAMETER

    O.F. OUTSIDE FACE

    O.H. OVERHEAD

    OHD OVERHEAD DOOR

    PNT PAINTED OR PAINT

    PTN PARTITION

    PERP. PERPENDICULAR

    PLAM PLASTIC LAMINATE

    PL. PLATE

    PCF POUNDS PER CUBIC FOOT

    PLF POUNDS PER LINEAL FOOT

    PSF POUNDS PER SQUARE FOOT

    PSI POUNDS PER SQUARE INCH

    PROT. PROTECTION

    QTY. QUANTITY

    RAD. RADIUS

    REINF. REINFORCED

    REQ REQUIRED

    R.D. ROOF DRAIN

    RM. ROOM

    R.O. ROUGH OPENING

    SCHED. SCHEDULE

    SHT. SHEET

    GFCI GOVERNMENT FURNISHEDCONTRACTOR INSTALLED

    GFGI GOVERNMENT FURNISHEDGOVERNMENT INSTALLED

    GND. GROUND

    GYP. BD. GYPSUM BOARD

    GWB. GYPSUM WALL BOARD

    HC. HANDICAPPED

    HDWR. HARDWARE

    HSA HEADED STUD ANCHOR

    HVAC HEATING/VENTILATION/AIRCONDITIONING

    HT. HEIGHT

    H.M. HOLLOW METAL

    HORIZ. HORIZONTAL

    HR. HOUR

    HYD HYDRANT

    IN. INCHES OR INCH

    INFO. INFORMATION

    I.D. INSIDE DIAMETER

    I.F. INSIDE FACE

    INSUL. INSULATION

    INT. INTERIOR

    LAV. LAVATORY

    LT. LIGHT

    LT. WT. LIGHT WEIGHT

    MAINT. MAINTENANCE

    MANUF. MANUFACTURER

    MFR. MANUFACTURER

    M.O. MASONRY OPENING

    MAT. MATERIAL

    MAX. MAXIMUM

    MECH. MECHANICAL

    DTL. DETAIL

    Ø DIAMETER

    DIA. DIAMETER

    DBL. DOUBLE

    DWGS. DRAWINGS

    EA. EACH

    E.F. EACH FACE

    E.S. EACH SIDE

    E.W. EACH WAY

    EWC ELECTRIC WATER COOLER

    EL. ELEVATION

    ELEV. ELEVATION

    EQ. EQUAL

    EXIST. EXISTING

    EXP. EXPANSION

    E.J. EXPANSION JOINT

    EXT. EXTERIOR

    FT. FEET OR FOOT

    F.V. FIELD VERIFY

    FIN FINISH

    FF FINISH FLOOR

    FE FIRE EXTINGUISHER

    FEC FIRE EXTINGUISHER CABINET

    FLR. FLOOR

    FD FLOOR DRAIN

    FTG. FOOTING

    FDN. FOUNDATION

    GA. GAGE/GAUGE

    GAL. GALLON

    GPM GALLONS PER MINUTE

    GALV. GALVANIZED

    GOVT. GOVERNMENT

    ABV ABOVE

    A.F.F. ABOVE FINISH FLOOR

    ADJ. ADJUSTABLE

    ALUM. ALUMINUM

    ASTM AMERICAN SOCIETY FOR TESTINGMATERIALS

    AB ANCHOR BOLT

    < ANGLE

    APPROX. APPROXIMATE

    ARCH. ARCHITECTURAL OR ARCHITECT

    @ AT

    BP BASE PLATE

    BRG. BEARING

    B.M. BENCHMARK

    BTWN BETWEEN

    BITUM. BITUMINOUS

    BD. BOARD

    BOT. BOTTOM

    B.O. BOTTOM OF

    BLDG BUILDING

    CLG. CEILING

    CL CENTER LINE

    CT CERAMIC TILE

    CLR. CLEAR

    COL COLUMN

    CONC CONCRETE

    CMU CONCRETE MASONRY UNIT

    CONST. CONSTRUCTION

    CONT. CONTINUOUS

    C.J. CONTROL JOINT

    COORD. COORDINATE

    DBA DEFORMED BAR ANCHOR

    DEPT DEPARTMENT

    DRAWING INDEXSHEET

    NUMBER SHEET NAMEGENERAL

    GI000 COVER SHEET

    GI001 DRAWING INDEX, SYMBOLS AND ABBREVIATIONS

    GI002 CODE SUMMARY AND DATA

    GI003 CODE ANALYSIS

    PHASE 1 GI002 CODE SUMMARY AND DATA

    PHASE 1 GI003 CODE ANALYSIS

    6

    CIVIL

    C001 CIVIL GENERAL NOTES

    C100 DEMOLITION PLAN

    C200 SITE PLAN

    C300 GRADING AND DRAINAGE PLAN

    C400 UTILITY PLAN

    C500 EROSION CONTROL PLAN

    C600 CIVIL DETAILS

    S000 GENERAL STRUCTURAL NOTES

    S100 SCHEDULES AND DETAILS

    9

    LANDSCAPE

    L101 SITE PLAN

    L102 SITE DETAILS

    L200 IRRIGATION PLAN

    L201 IRRIGATION DETAILS

    L202 IRRIGATION DETAILS

    L300 PLANTING PLAN

    L301 PLANTING DETAILS

    7

    ARCHITECTURAL

    AD110 DEMOLITION PLANS

    AE110 FINISH FLOOR PLAN, SECTIONS, DETAILS, DOOR SCHEDULE AND TYPES

    AE130 REFLECTED CEILING PLANS AND DETAILS

    AE140 ROOF PLAN

    AE150 EXTERIOR BUILDING DONOR SIGNAGE

    AE151 EXTERIOR BUILDING DONOR SIGNAGE

    AE200 EXTRIOR ELEVATIONS - PHASE 2A

    7

    MD101 LEVEL 1 MECHANICAL DEMO PLAN

    MH001 MECHANICAL LEGEND, SYMBOLS & ABBREVIATIONS

    MH101 LEVEL 1 MECHANICAL PLAN

    MH601 MECHANICAL SCHEDULES & DETAILS

    4

    ELECTRICAL

    EE-001 GENERAL NOTES & DETAILS

    EE-002 LIGHT FIXTURE/MECHANICAL/ RELAY/PANEL SCHEDULES

    ED-101 MAIN FLOOR PLAN - ELECTRICAL DEMO

    EFA-101 MAIN FLOOR PLAN - FIRE ALARM/ SYSTEMS

    EL-101 MAIN FLOOR PLAN - LIGHTING

    EP-101 MAIN FLOOR PLAN - POWER

    ES-101 SITE PLAN - ELECTRICAL

    7

    40

    PROJECTNORTH

  • DNUP DN UP

    DN UP

    CODE PLAN LEGEND

    CORRIDOR TRIBUTARY LOAD

    TOTAL NO. OF OCCUPANTS AT EXIT

    NO. OF OCCUPANTS

    FIRE EXTINGUISHER CABINETFEC

    2 HR. RATED WALL

    AREA NOT IN SCOPE

    LOCATION

    OCCUPANT NUMBER

    REQUIRED STAIR WIDTH

    PROVIDED STAIR WIDTH

    (EXIT WIDTH FACTOR)STAIR(0.2)

    XX OCCX'-X" RX'-X" P

    EXIT(0.15)

    X,XXX OCC

    X'-X" R

    X'-X" P

    1st LOCATION

    OCCUPANT NUMBER

    REQUIRED EXIT WIDTH

    PROVIDED EXIT WIDTH

    (EXIT WIDTH FACTOR) GOVERNING FLOOR

    NET NO. OF OCCUPANTS AT ASSEMBLY*

    FE

    NOTE

    FIRE EXTINGUISHER

    DFE DRINKING FOUNTAIN, EXISTING

    DFN DRINKING FOUNTAIN, NEW

    FIRE EXTINGUISHER CABINET, NEWFEC*

    1. EXISTING INTERIOR BUILDING LAYOUT, OCCUPANCY TYPE AND USE IS REMAINING UNCHANGED. PLEASE REFERENCE ATTACHED APPROVED PHASE 1 CODE REVIEW SHEETS FOR REFERENCE.

    2. THERE IS NO NEW WORK ASSOCIATED WITH BASEMENT LEVEL AND LEVEL 2.

    3. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, WILL BE ILLUMINATED TO A LEVEL OF NOT LESS THAN ONE FOOT-CANDLE AT THE WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED PER SECTIONS 1008.1; 1008.2.

    4. SEE GI003 FOR U OF U CODE ANALYSIS DATA.

    OCCUPANT LOAD FACTOR PER TABLE 1004.1.2

    OCCUPANT LOAD FACTOR IS 100 UNLESS NOTED OTHERWISE

    EXISTING, 1 HR. RATED WALL

    EXIT(0.15)

    66 OCC

    10" R

    6'-0" P

    1st

    EXIT(0.15)

    182 OCC

    2'-4" R

    6'-0" P

    1st

    182

    EXIT(0.15)

    182 OCC

    2'-4" R

    6'-0" P

    1st

    66

    FEC

    FEC

    FEC

    FEC

    FEC

    FEC

    182

    EXIT(0.15)

    66 OCC

    10" R

    6'-0" P

    1st

    66

    EXISTING EXTERIOR VESTIBULE DOORS

    NEW INTERIOR VESTIBULE DOORS

    NEW INTERIOR VESTIBULE DOORS

    NEW EXTERIOR VESTIBULE DOORS

    EXISTING DOORS AT GLASS CONNECTOR BETWEEN BUILDING 73 AND 72

    375 WEST 200 SOUTHSALT LAKE CITY, UT 84101

    801.521.8600801.521.7913

    PF

    www.gsbsarchitects.com

    BREMS

    NO. 119149

    DAVID PAUL

    LI

    CE

    NS E D A RC

    H

    IT

    EC

    T

    ST

    ATE

    OF UTAH

    PROJECTNORTH

    OWNER PROJECT NO.:

    GSBS PROJECT NO.:

    ISSUED DATE:

    REVISIONS:

    REVREV

    05/18/2020

    2018.064.01

    CODE SUMMARY AND DATA

    UNIVERSITY OF UTAH

    U OF U BLDG 73IMPROVEMENTSPHASE 2A

    332 SOUTH 1400 EASTSALT LAKE CITY, UT 84112

    1795 EAST SOUTH CAMPUS DRIVE RM 201SALT LAKE CITY, UT 84112

    CONSTRUCTION

    DOCUMENTS

    GI002GI0021/16" = 1'-0"GI002

    1 CODE PLAN - LEVEL ONE (PHASE 2A)

  • 375 WEST 200 SOUTHSALT LAKE CITY, UT 84101

    801.521.8600801.521.7913

    PF

    www.gsbsarchitects.com

    BREMS

    NO. 119149

    DAVID PAUL

    LI

    CE

    NS E D A RC

    H

    IT

    EC

    T

    ST

    ATE

    OF UTAH

    OWNER PROJECT NO.:

    GSBS PROJECT NO.:

    ISSUED DATE:

    REVISIONS:

    REVREV

    05/18/2020

    2018.064.01

    CODE ANALYSIS

    UNIVERSITY OF UTAH

    U OF U BLDG 73IMPROVEMENTSPHASE 2A

    332 SOUTH 1400 EASTSALT LAKE CITY, UT 84112

    1795 EAST SOUTH CAMPUS DRIVE RM 201SALT LAKE CITY, UT 84112

    CONSTRUCTION

    DOCUMENTS

    GI003GI003

    NO CHANGES, PLEASE REFERENCE ATTACHED APPROVED PHASE 1 CODE ANALYSIS

    NO CHANGES, PLEASE REFERENCE ATTACHED APPROVED PHASE 1 CODE ANALYSIS

    NOT CHANGES, PLEASE REFERENCE ATTACHED APPROVED PHASE 1 CODE ANALYSIS

    NOT CHANGES, PLEASE REFERENCE ATTACHED APPROVED PHASE 1 CODE ANALYSIS

    NO CHANGES, PLEASE REFERENCE ATTACHED APPROVED PHASE 1 CODE ANALYSIS

  • 31'

    83'

    41'

    46'

    4'

    23'

    5'

    22'

    19'

    21'

    26'

    14'

    35'

    33'

    7'

    17'

    14' 32'

    28'

    67'

    33' 32'

    21'

    22' 65'

    21'

    19'

    13'

    35'

    24'

    18' 29'

    47'

    19'

    22'

    33' 32'

    19'

    19' 3

    1'

    11'

    37'

    9'

    61'

    34'

    29'

    12'

    12'

    17'

    102'

    60'

    32'

    11'

    16'

    33'

    28'

    9'

    73' 29'

    14'

    14'

    10'

    57'

    30'

    18'

    11'

    34'

    9'

    30'

    17'

    14'

    7'

    18'

    16'

    46' 10'

    33'

    30'

    51'

    30'

    33'

    15'

    19'

    65'

    30'

    27'

    21'

    5'

    54'

    25'

    18'

    7'

    35'

    20'

    15'

    20'

    31'

    17'

    17'

    36' 15'

    30'

    22'

    21'

    53'

    8'

    8'

    8'

    CODE PLAN LEGEND

    CORRIDOR TRIBUTARY LOAD

    TOTAL NO. OF OCCUPANTS AT EXIT

    NO. OF OCCUPANTS

    FIRE EXTINGUISHER CABINETFEC

    2 HR. RATED WALL

    1 HR. RATED WALL

    OCCUPANCY TYPE A3

    OCCUPANCY IS TYPE B UNLESS NOTED OTHERWISE

    LOCATION

    OCCUPANT NUMBER

    REQUIRED STAIR WIDTH

    PROVIDED STAIR WIDTH

    (EXIT WIDTH FACTOR)STAIR(0.2)XX OCCX'-X" RX'-X" P

    EXIT(0.15)

    X,XXX OCC

    X'-X" R

    X'-X" P

    1st LOCATION

    OCCUPANT NUMBER

    REQUIRED EXIT WIDTH

    PROVIDED EXIT WIDTH

    (EXIT WIDTH FACTOR) GOVERNING FLOOR

    OCCUPANCY TYPE S2

    OCCUPANCY TYPE B

    NET NO. OF OCCUPANTS AT ASSEMBLY*

    FE

    NOTE

    1. SEE GI003 FOR UU CODE ANALYSIS TABLE.

    FIRE EXTINGUISHER

    DFE DRINKING FOUNTAIN, EXISTING

    DFN DRINKING FOUNTAIN, NEW

    FIRE EXTINGUISHER CABINET, NEWFEC*

    2. ALL STAIRS ARE NOT IN PROJECT SCOPE.

    3. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, WILL BE ILLUMINATED TO A LEVEL OF NOT LESS THAN ONE FOOT-CANDLE AT THE WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED PER SECTIONS 1008.1; 1008.2.

    OCCUPANT LOAD FACTOR PER TABLE 1004.1.2

    OCCUPANT LOAD FACTOR IS 100 UNLESS NOTED OTHERWISE

    EXISTING, 1 HR. RATED WALL

    EXISTING TUNNEL TO BUILDING 72, NOT PART OF EGRESS PLAN

    735 SF

    015

    49432 SF

    001B

    2

    266 SF

    001C

    1

    180 SF

    001D

    1

    127 SF

    001E

    1

    968 SF

    012

    25

    870 SF

    011

    60

    1,048 SF

    001A

    4

    3,207 SF

    010

    11

    133 SF

    016

    1

    66 SF

    005A

    1

    66 SF

    005D

    1

    69 SF

    004A

    1

    62 SF

    004C

    1

    167 SF

    003

    2

    66 SF

    005B

    1

    66 SF

    005C

    1

    69 SF

    004B

    1

    98 SF

    004D

    1

    64 SF

    004E

    1

    STAIR(0.2)73 OCC1'-3" R3'-6" P

    74 73 EXIT(0.15)

    73 OCC

    0'-11" R

    3'-0" P

    1st

    3'-0

    "3

    '-0"

    STAIR 1

    STAIR 3

    STAIR(0.2)74 OCC1'-3" R3'-6" P

    EXIT(0.15)

    74 OCC

    0'-11" R

    3'-0" P

    1st

    *

    FEC

    FEC

    FEC*29'-4"

    LACTATION ROOM

    300

    15

    # OF STATIONS

    300

    300

    300

    300

    15

    300

    73

    '-0"

    44'-8"

    43

    '-4"

    28

    '-4 3

    /4"

    34'-3"

    4

    4

    4

    EXISTING ELEVATOR, NOT PART OF EGRESS PLAN

    EXISTING ACCESS TO BUILDING 72, NOT PART OF EGRESS PLAN

    5,573 SF

    130

    56

    97 SF

    150

    1

    94 SF

    152

    1

    94 SF

    154

    1

    94 SF

    155

    1

    94 SF

    156

    1

    95 SF

    158

    2

    262 SF

    160

    3

    197 SF

    162

    2

    197 SF

    163

    2

    197 SF

    164

    2

    221 SF

    166

    3

    134 SF

    169

    2

    201 SF

    117

    2

    466 SF

    122

    5

    442 SF

    115

    30

    1,754 SF

    112

    89

    925 SF

    109

    48

    635 SF

    108

    34

    649 SF

    101

    6143 SF

    101A

    2

    191 SF

    103

    2

    214 SF

    104

    3

    1,846 SF

    107

    93

    1,846 SF

    110

    94

    875 SF

    111

    44

    103 SF

    100P

    1

    2,318 SF

    100

    24

    1,498 SF

    100F

    15

    EXIT(0.15)

    132 OCC

    1'-8" R

    12'-0" P

    1st

    EXIT(0.15)

    28 OCC

    4" R

    3'-0" P

    1st

    STAIR 1

    STAIR 2

    STAIR 3

    ACTING/DANCINGCLASSROOM

    ACTING/DANCINGCLASSROOM

    ACTING/DANCINGCLASSROOM

    ACTING/DANCINGCLASSROOM

    EXIT(0.15)

    109 OCC

    2'-8" R

    1'-4" P

    1st EXIT(0.15)

    132 OCC

    1'-10" R

    6'-0" P

    1st

    ?

    ?

    ?

    505 SF

    116

    6

    109

    182 182

    205

    17

    89

    EXIT(0.15)

    132 OCC

    1'-10" R

    6'-0" P

    1st

    28 28

    26

    28

    28

    132

    EXIT(0.15)

    26 OCC

    4" R

    3'-0" P

    1stEXIT(0.15)

    26 OCC

    4" R

    3'-0" P

    1st

    DFE

    DRINKING FOUNTAIN, NEWADA COMPLIANT, PARTITION WALLS ON BOTH SIDES

    DFE

    DFE

    FEC

    FEC

    FEC

    FEC

    FEC

    FEC

    *

    *

    *

    55

    '-4 3

    /4"

    31'-7"

    55

    '-4 1

    /2"

    48

    '-11

    1/2

    "

    37'-6 3/4"

    MAIL ROOM

    100

    80'-1

    0 1

    /4"

    69'-4 3/8"

    44'-6"

    19

    '-6"

    20

    20

    20

    20

    20

    15

    222 SF

    167

    3100

    100

    20200 SF

    119

    3

    133 SF

    120

    3

    927 SF

    170

    3

    505 SF

    116

    6

    100

    104

    19

    '-10

    3/4

    "

    34'-11 3/4"

    28

    '-2 1

    /4"

    4'-1

    3/4

    "

    3

    2'-1

    1"

    9'-2

    "

    4

    5

    170 SF

    235

    2

    170 SF

    234

    2

    170 SF

    232

    2

    170 SF

    231

    2

    170 SF

    230

    2

    170 SF

    228

    2

    170 SF

    226

    2

    143 SF

    225

    2

    160 SF

    223

    2

    160 SF

    221

    2

    160 SF

    219

    2

    160 SF

    218

    2

    154 SF

    217

    2

    1,199 SF

    210

    25

    1,457 SF

    220

    30

    951 SF

    242

    64

    143 SF

    236

    2

    160 SF

    238

    2

    160 SF

    239

    2

    160 SF

    240

    2

    159 SF

    241

    2

    315 SF

    246

    4

    104 SF

    206

    2

    144 SF

    202

    2

    140 SF

    203

    2

    140 SF

    204

    2

    140 SF

    205

    2

    140 SF

    207

    2

    140 SF

    209

    2

    140 SF

    211

    2

    140 SF

    212

    2

    146 SF

    215

    2

    240 SF

    252

    5

    STAIR(0.2)103 OCC

    1'-8" R3'-6" P

    EXIT(0.15)

    103 OCC

    1'-3" R

    3'-0" P

    1st

    STAIR 1STAIR 3

    STAIR 2

    9696

    COSTUME SHOP

    THEATER PROP SHOP

    DRAFTING CLASSROOM

    391 SF

    208

    27

    *

    STAIR(0.2)103 OCC

    1'-8" R3'-6" P

    EXIT(0.15)

    103 OCC

    1'-3" R

    3'-0" P

    1st

    DFE

    FEC

    FECFEC

    *

    29'-6 1/2"

    51

    '-6 3

    /4"

    15

    50

    5015

    50

    59'-5 3/4"

    14'-5 3/4"

    27

    '-0 1

    /2"

    24

    '-6 3

    /4"

    BREMS

    NO. 119149

    DAVID PAUL

    LI

    CE

    NS E D A R C

    H

    IT

    EC

    T

    ST

    ATE

    OF UTAH

    375 WEST 200 SOUTHSALT LAKE CITY, UT 84101

    801.521.8600801.521.7913

    PF

    www.gsbsarchitects.com

    OWNER PROJECT NO.:

    GSBS PROJECT NO.:

    ISSUED DATE:

    REVISIONS:

    REVREV

    55

    03/14/2019

    2018.064.00

    CODE SUMMARY AND

    DATA

    UNIVERSITY OF UTAH

    CAMPUS PLANNING, DESIGN

    & CONSTRUCTION

    U OF U BLDG 73THEATRE &DEVELOPMENTREMODEL

    332 SOUTH 1400 EASTSALT LAKE CITY, UT 84112

    1795 EAST SOUTH CAMPUS DRIVE RM 201SALT LAKE CITY, UT 84112

    BID PAC #3 100%

    CONSTRUCTION

    DOCUMENTS

    GI002GI002

    1/16" = 1'-0"GI002

    1 CODE PLAN - BASEMENT

    1/16" = 1'-0"GI002

    2 CODE PLAN - LEVEL ONE

    1/16" = 1'-0"GI002

    3 CODE PLAN - LEVEL TWO

    1

    1

    *4 OF ELECTRIC WATER DISPENSERS WILL BE PROVIDED AT BREAK ROOMS AS DRINKING FOUNTAIN.*

    2

    2

    1 2/6/19 Code review response #1/BIDPAC #2 Addendum #2

    2 2/20/2019 Code review response #2/BIDPAC #2

    3 3/12/2019 Code review response #3/BIDPAC #2

    4 3/27/2019 Code review response #1/BIDPAC #3

    5 4/12/2019 Code review response #2/BIDPAC #3

    2

    3

    4

    1

    PHASE 1

    PH

    AS

    E 1

    AP

    PR

    OV

    ED

    CO

    DE

    SH

    EE

    TP

    RO

    VID

    ED

    FO

    R R

    EF

    ER

    EN

    CE

    ON

    LY

  • BREMS

    NO. 119149

    DAVID PAUL

    LI

    CE

    NS E D A R C

    H

    IT

    EC

    T

    ST

    ATE

    OF UTAH

    375 WEST 200 SOUTHSALT LAKE CITY, UT 84101

    801.521.8600801.521.7913

    PF

    www.gsbsarchitects.com

    OWNER PROJECT NO.:

    GSBS PROJECT NO.:

    ISSUED DATE:

    REVISIONS:

    REVREV

    22

    03/14/2019

    2018.064.00

    CODE ANALYSIS

    UNIVERSITY OF UTAH

    CAMPUS PLANNING, DESIGN

    & CONSTRUCTION

    U OF U BLDG 73THEATRE &DEVELOPMENTREMODEL

    332 SOUTH 1400 EASTSALT LAKE CITY, UT 84112

    1795 EAST SOUTH CAMPUS DRIVE RM 201SALT LAKE CITY, UT 84112

    BID PAC #3 100%

    CONSTRUCTION

    DOCUMENTS

    GI003GI003

    1

    1 2/20/2019 Code review response #2/BIDPAC #2

    2 3/12/2019 Code review response #3/BIDPAC #2

    *

    4 OF ELECTRIC WATER DISPENSERS WILL BE PROVIDED AT BREAK ROOMS AS DRINKING FOUNTAIN.*

    1

    2 S-1

    PHASE 1

    PH

    AS

    E 1

    AP

    PR

    OV

    ED

    CO

    DE

    SH

    EE

    TP

    RO

    VID

    ED

    FO

    R R

    EF

    ER

    EN

    CE

    ON

    LY

  • NOTE: MAY CONTAIN ABBREVIATIONS THAT ARE NOT USED IN THIS PLAN SET.

    ABBREVIATIONS

    1. ALL CONSTRUCTION MUST STRICTLY FOLLOW THE STANDARDS AND SPECIFICATIONS SET FORTH BY: THE DESIGN ENGINEER, LOCALAGENCY JURISDICTION, APWA (CURRENT EDITION), AND THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (M.U.T.C.D.). THEORDER LISTED ABOVE IS ARRANGED BY SENIORITY. THE LATEST EDITION OF ALL STANDARDS AND SPECIFICATIONS MUST BEADHERED TO. IF A CONSTRUCTION PRACTICE IS NOT SPECIFIED BY ANY OF THE LISTED SOURCES, CONTRACTOR MUST CONTACTDESIGN ENGINEER FOR DIRECTION.

    2. CONTRACTOR TO STRICTLY FOLLOW THE MOST CURRENT COPY OF THE SOILS REPORT FOR THIS PROJECT. ALL GRADINGINCLUDING BUT NOT LIMITED TO CUT, FILL, COMPACTION, ASPHALT SECTION, SUBBASE, TRENCH EXCAVATION/BACKFILL, SITEGRUBBING, AND FOOTINGS MUST BE COORDINATED DIRECTLY WITH SOILS REPORT.

    3. CONTRACTOR MUST VERIFY ALL EXISTING CONDITIONS BEFORE BIDDING, AND BRING UP ANY QUESTIONS BEFORE SUBMITTING BID.

    4. CONTRACTOR SHALL PROVIDE A CONSTRUCTION SCHEDULE IN ACCORDANCE WITH THE CITY, STATE, OR COUNTY REGULATIONS FORWORKING IN THE PUBLIC WAY.

    5. CONTRACTOR SHALL BE RESPONSIBLE FOR DUST CONTROL ACCORDING TO GOVERNING AGENCY STANDARDS. WET DOWN DRYMATERIALS AND RUBBISH TO PREVENT BLOWING.

    6. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO ADJACENT SURFACE IMPROVEMENTS.

    7. CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY SETTLEMENT OF OR DAMAGE TO EXISTING UTILITIES.

    8. THE CONTRACTOR IS RESPONSIBLE TO FURNISH ALL MATERIALS TO COMPLETE THE PROJECT.

    9. ALL EXPOSED SURFACES WILL HAVE A TEXTURED FINISH, RUBBED, OR BROOMED. ANY "PLASTERING" OF NEW CONCRETE WILL BEDONE WHILE IT IS STILL "GREEN".

    10. PRIOR TO STARTING CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THAT ALL REQUIRED PERMITS ANDAPPROVALS HAVE BEEN OBTAINED. NO CONSTRUCTION OR FABRICATION SHALL BEGIN UNTIL THE CONTRACTOR HAS RECEIVED ANDTHOROUGHLY REVIEWED ALL PLANS AND OTHER DOCUMENTS APPROVED BY ALL OF THE PERMITTING AUTHORITIES.

    11. THE LOCATIONS OF UNDERGROUND FACILITIES SHOWN ON THESE PLANS ARE BASED ON FIELD SURVEYS AND LOCAL UTILITYCOMPANY RECORDS. IT SHALL BE THE CONTRACTOR'S FULL RESPONSIBILITY TO CONTACT THE VARIOUS UTILITY COMPANIES TOLOCATE THEIR FACILITIES PRIOR TO PROCEEDING WITH CONSTRUCTION. NO ADDITIONAL COMPENSATION SHALL BE PAID TO THECONTRACTOR FOR DAMAGE AND REPAIR TO THESE FACILITIES CAUSED BY HIS WORK FORCE. CONTRACTOR SHALL STARTINSTALLATION AT LOW POINT OF ALL NEW GRAVITY UTILITY LINES.

    12. ALL DIMENSIONS, GRADES, AND UTILITY DESIGN SHOWN ON THE PLANS SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TOCONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST, PRIOR TO PROCEEDING WITHCONSTRUCTION FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FORWORK HAVING TO BE REDONE DUE TO THE DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS, IF SUCHNOTIFICATION HAS NOT BEEN GIVEN.

    13. NO CHANGE IN DESIGN LOCATION OR GRADE WILL BE MADE BY THE CONTRACTOR WITHOUT THE WRITTEN APPROVAL OF THEPROJECT ENGINEER.

    14. NATURAL VEGETATION AND SOIL COVER SHALL NOT BE DISTURBED PRIOR TO ACTUAL CONSTRUCTION OF A REQUIRED FACILITY ORIMPROVEMENT. MASS CLEARING OF THE SITE IN ANTICIPATION OF CONSTRUCTION SHALL BE AVOIDED.

    15. CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING, MAINTAINING, OR RESTORING ALL MONUMENTS AND MONUMENTREFERENCE MARKS WITHIN THE PROJECT SITE. CONTACT THE CITY OR COUNTY SURVEYOR FOR MONUMENT LOCATIONS ANDCONSTRUCTION DETAILS.

    16. EXISTING UTILITY INFORMATION SHOWN IS FOR INFORMATIONAL PURPOSES ONLY. IT IS DERIVED FROM ON-SITE SURVEY AND/ORUTILITY MAPPING PROVIDED TO THE ENGINEER, AND THEREFORE UTILITIES MAY NOT BE LOCATED CORRECTLY, EITHERHORIZONTALLY OR VERTICALLY, AND MAY NOT BE ALL INCLUSIVE. CONTRACTOR IS REQUIRED TO FOLLOW THE PROCEDUREOUTLINED BELOW:

    16.1. CONTRACTOR IS REQUIRED TO LOCATE AND POTHOLE ALL EXISTING UTILITY LINES (BOTH HORIZONTALLY AND VERTICALLY)THAT AFFECT THE PROJECT CONSTRUCTION, EITHER ON-SITE OR OFF-SITE, AND DETERMINE IF THERE ARE ANY CONFLICTSWITH THE DESIGN OF THE SITE AS SHOWN ON THE APPROVED PLANS PRIOR TO ANY CONSTRUCTION. IF IT IS DETERMINEDTHAT CONFLICTS EXIST BETWEEN EXISTING UTILITIES AND DESIGN UTILITIES (OR ANOTHER ASPECT OF PROPOSEDCONSTRUCTION) THE ENGINEER MUST BE NOTIFIED IMMEDIATELY TO CORRECT THE CONFLICTS BEFORE ANY WORK CAN BEGIN.IF THE CONTRACTOR FAILS TO FOLLOW THIS ABSOLUTE REQUIREMENT AND CONFLICTS ARISE DURING CONSTRUCTION THECONTRACTOR WILL BEAR THE SOLE RESPONSIBILITY TO FIX THE CONFLICTS.

    16.2. CONTRACTOR IS REQUIRED TO VERIFY THAT PROPER COVER AND PROTECTION OF EXISTING UTILITY LINES IS MAINTAINED ORATTAINED WITHIN THE DESIGN ONCE VERIFICATION OF THE EXISTING UTILITIES IS COMPLETED AS OUTLINED IN 16.1 ABOVE.

    16.3. IN ADDITION TO 16.1 AND 16.2 ABOVE THE CONTRACTOR WILL VERIFY DEPTHS OF UTILITIES IN THE FIELD BY "POTHOLING" AMINIMUM OF 300 FEET AHEAD OF PROPOSED PIPELINE CONSTRUCTION TO AVOID POTENTIAL CONFLICTS WITH DESIGNEDPIPELINE ALIGNMENT AND GRADE AND EXISTING UTILITIES.

    16.4. IF A CONFLICT ARISES BETWEEN EXISTING UTILITIES AND DESIGN UTILITIES (OR ANOTHER ASPECT OF PROPOSEDCONSTRUCTION) AS DETERMINED UNDER 16.1, 16.2 OR 16.3 THE CONTRACTOR WILL NOTIFY THE ENGINEER IMMEDIATELY TORESOLVE THE CONFLICT.

    16.5. IF A CONFLICT ARISES BETWEEN EXISTING UTILITIES AND DESIGN UTILITIES (OR ANOTHER ASPECT OF PROPOSEDCONSTRUCTION) RESULTING FROM THE CONTRACTOR'S NEGLIGENCE TO IDENTIFY AND/OR “POTHOLE” EXISTING UTILITIES ASREQUIRED IN 16.1, 16.2 AND 16.3 ABOVE, THE CONTRACTOR WILL BE REQUIRED TO RESOLVE THE CONFLICT WITHOUTADDITIONAL COST OR CLAIM TO THE OWNER OR ENGINEER.

    17. ANY AREA OUTSIDE THE LIMIT OF WORK THAT IS DISTURBED SHALL BE RESTORED TO ITS ORIGINAL CONDITION AT NO COST TOOWNER.

    18. CONSULT ALL OF THE DRAWINGS AND SPECIFICATIONS FOR COORDINATION REQUIREMENTS BEFORE COMMENCING CONSTRUCTION.

    19. AT ALL LOCATIONS WHERE EXISTING PAVEMENT ABUTS NEW CONSTRUCTION, THE EDGE OF THE EXISTING PAVEMENT SHALL BESAWCUT TO A CLEAN, SMOOTH EDGE.

    20. ALL CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH THE MOST RECENT, ADOPTED EDITION OF ADA ACCESSIBILITYGUIDELINES.

    21. CONTRACTOR SHALL, AT THE TIME OF BIDDING AND THROUGHOUT THE PERIOD OF THE CONTRACT, BE LICENSED IN THE STATE OFUTAH AND SHALL BE BONDABLE FOR AN AMOUNT REQUIRED BY THE OWNER.

    22. CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE ALL WATER, POWER, SANITARY FACILITIES AND TELEPHONE SERVICES ASREQUIRED FOR THE CONTRACTOR'S USE DURING CONSTRUCTION.

    23. CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY SCHEDULING INSPECTION AND TESTING OF ALL FACILITIES CONSTRUCTEDUNDER THIS CONTRACT. ALL TESTING SHALL CONFORM TO THE REGULATORY AGENCY'S STANDARD SPECIFICATIONS. ALLRE-TESTING AND/OR RE-INSPECTION SHALL BE PAID FOR BY THE CONTRACTOR.

    24. IF EXISTING IMPROVEMENTS NEED TO BE DISTURBED AND/OR REMOVED FOR THE PROPER PLACEMENT OF IMPROVEMENTS TO BECONSTRUCTED BY THESE PLANS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING EXISTING IMPROVEMENTS FROMDAMAGE. COST OF REPLACING OR REPAIRING EXISTING IMPROVEMENTS SHALL BE INCLUDED IN THE UNIT PRICE BID FOR ITEMSREQUIRING REMOVAL AND/OR REPLACEMENT. THERE WILL BE NO EXTRA COST DUE TO THE CONTRACTOR FOR REPLACING ORREPAIRING EXISTING IMPROVEMENTS.

    25. WHENEVER EXISTING FACILITIES ARE REMOVED, DAMAGED, BROKEN, OR CUT IN THE INSTALLATION OF THE WORK COVERED BYTHESE PLANS OR SPECIFICATIONS, SAID FACILITIES SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE WITH MATERIALS EQUALTO OR BETTER THAN THE MATERIALS USED IN THE ORIGINAL EXISTING FACILITIES. THE FINISHED PRODUCT SHALL BE SUBJECT TOTHE APPROVAL OF THE OWNER, THE ENGINEER, AND THE RESPECTIVE REGULATORY AGENCY.

    26. CONTRACTOR SHALL MAINTAIN A NEATLY MARKED SET OF FULL-SIZE RECORD DRAWINGS SHOWING THE FINAL LOCATION ANDLAYOUT OF ALL STRUCTURES AND OTHER FACILITIES. RECORD DRAWINGS SHALL REFLECT CHANGE ORDERS, ACCOMMODATIONS,AND ADJUSTMENTS TO ALL IMPROVEMENTS CONSTRUCTED. WHERE NECESSARY, SUPPLEMENTAL DRAWINGS SHALL BE PREPAREDAND SUBMITTED BY THE CONTRACTOR. PRIOR TO ACCEPTANCE OF THE PROJECT, THE CONTRACTOR SHALL DELIVER TO THEENGINEER ONE SET OF NEATLY MARKED RECORD DRAWINGS SHOWING THE INFORMATION REQUIRED ABOVE. RECORD DRAWINGSSHALL BE REVIEWED AND THE COMPLETE RECORD DRAWING SET SHALL BE CURRENT WITH ALL CHANGES AND DEVIATIONSREDLINED AS A PRECONDITION TO THE FINAL PROGRESS PAYMENT APPROVAL AND/OR FINAL ACCEPTANCE.

    27. WHERE THE PLANS OR SPECIFICATIONS DESCRIBE PORTIONS OF THE WORK IN GENERAL TERMS BUT NOT IN COMPLETE DETAIL, IT ISUNDERSTOOD THAT ONLY THE BEST GENERAL PRACTICE IS TO PREVAIL AND THAT ONLY MATERIALS AND WORKMANSHIP OF THEFIRST QUALITY ARE TO BE USED.

    28. ALL EXISTING GATES AND FENCES TO REMAIN UNLESS OTHERWISE NOTED ON PLANS. PROTECT ALL GATES AND FENCES FROMDAMAGE.

    29. ALL EXISTING TREES ARE TO REMAIN UNLESS OTHERWISE NOTED ON PLANS. PROTECT ALL TREES FROM DAMAGE.

    30. ASPHALT MIX DESIGN MUST BE SUBMITTED AND APPROVED BY THE GOVERNING AGENCY PRIOR TO THE PLACEMENT.

    31. CONTRACTORS ARE RESPONSIBLE FOR ALL OSHA REQUIREMENTS ON THE PROJECT SITE.

    32. A UPDES (UTAH POLLUTANT DISCHARGE ELIMINATION SYSTEM) PERMIT IS REQUIRED FOR ALL CONSTRUCTION ACTIVITIES 1 ACRE ORMORE AS WELL AS A STORM WATER POLLUTION PREVENTION PLAN.

    1. EXISTING UTILITY INFORMATION SHOWN IS FOR INFORMATIONAL PURPOSES ONLY. IT IS DERIVED FROM ON-SITE SURVEYAND MAY NOT BE LOCATED CORRECTLY AND IS NOT ALL INCLUSIVE. CONTRACTOR SHALL FIELD LOCATE ALL UTILITIESWITHIN THE PROJECT LIMITS BEFORE BEGINNING DEMOLITION/CONSTRUCTION.

    2. THERE MAY BE BURIED UTILITIES WITHIN THE LIMITS OF DISTURBANCE THAT ARE NOT SHOWN ON THE PLANS DUE TO LACKOF MAPPING OR RECORD INFORMATION. CONTRACTOR SHALL NOTIFY THE ENGINEER WHEN UNEXPECTED UTILITIES AREDISCOVERED.

    3. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR LOCATING AND PROTECTING FROM DAMAGE ALL EXISTING UTILITIESAND IMPROVEMENTS WHETHER OR NOT SHOWN ON THESE PLANS. THE FACILITIES AND IMPROVEMENTS ARE BELIEVED TOBE CORRECTLY SHOWN BUT THE CONTRACTOR IS REQUIRED TO SATISFY HIMSELF AS TO THE COMPLETENESS ANDACCURACY OF THE LOCATIONS. ANY CONTRACTOR PERFORMING WORK ON THIS PROJECT SHALL FAMILIARIZE HIMSELFWITH THE SITE AND SHALL BE HELD SOLELY RESPONSIBLE FOR ANY DAMAGE TO EXISTING FACILITIES RESULTING DIRECTLY,OR INDIRECTLY, FROM HIS OPERATIONS, WHETHER OR NOT SAID FACILITIES ARE SHOWN ON THESE PLANS.

    1. TRAFFIC CONTROL AND STRIPING TO CONFORM TO THE CURRENT MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES(M.U.T.C.D.).

    2. BARRICADING AND DETOURING SHALL BE IN CONFORMANCE WITH THE REQUIREMENTS OF THE CURRENT M.U.T.C.D.

    3. NO STREET SHALL BE CLOSED TO TRAFFIC WITHOUT WRITTEN PERMISSION FROM THE APPROPRIATE AGENCY, EXCEPTWHEN DIRECTED BY LAW ENFORCEMENT OR FIRE OFFICIALS.

    4. THE CONTRACTOR SHALL MAKE EVERY EFFORT TO PROVIDE FOR SMOOTH TRAFFIC FLOW AND SAFETY. ACCESS SHALL BEMAINTAINED FOR ALL PROPERTIES ADJACENT TO THE WORK.

    5. DETOURING OPERATIONS FOR A PERIOD OF SIX CONSECUTIVE CALENDAR DAYS, OR MORE, REQUIRE THE INSTALLATION OFTEMPORARY STREET STRIPING AND REMOVAL OF INTERFERING STRIPING BY SANDBLASTING. THE DETOURING STRIPINGPLAN OR CONSTRUCTION TRAFFIC CONTROL PLAN MUST BE SUBMITTED TO THE GOVERNING AGENCY FOR REVIEW ANDAPPROVAL.

    6. ALL TRAFFIC CONTROL DEVICES SHALL BE RESTORED TO THEIR ORIGINAL CONDITION AT THE END OF THE WORK TO THESATISFACTION OF THE GOVERNING AGENCY.

    7. TRAFFIC CONTROL DEVICES (TCDs) SHALL REMAIN VISIBLE AND OPERATIONAL AT ALL TIMES.

    8. ALL PERMANENT TRAFFIC CONTROL DEVICES CALLED FOR HEREON SHALL BE IN PLACE AND IN FINAL POSITION PRIOR TOALLOWING ANY PUBLIC TRAFFIC ONTO THE PORTIONS OF THE ROAD(S) BEING IMPROVED HEREUNDER, REGARDLESS OF THESTATUS OF COMPLETION OF PAVING OR OTHER OFF-SITE IMPROVEMENTS CALLED FOR BY THESE PLANS.

    9. THE CONTRACTOR SHALL PROVIDE BARRICADES, SIGNS, FLASHERS, OTHER EQUIPMENT AND FLAG PERSONS NECESSARYTO INSURE THE SAFETY OF WORKERS AND VISITORS.

    10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING UTAH TRANSIT AUTHORITY (UTA) IF THE CONSTRUCTIONINTERRUPTS OR RELOCATES A BUS STOP OR HAS AN ADVERSE EFFECT ON BUS SERVICE ON THAT STREET TO ARRANGEFOR TEMPORARY RELOCATION OF STOP.

    TRAFFIC CONTROL AND SAFETY NOTES

    GRADING AND DRAINAGE NOTES1. SITE GRADING SHALL BE PERFORMED IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS AND THE

    RECOMMENDATIONS SET FORTH IN THE GEOTECHNICAL REPORT AND ALL RELATED ADDENDUMS.

    2. THE CONTRACTOR SHALL STRIP AND CLEAR THE TOPSOIL, MAJOR ROOTS AND ORGANIC MATERIAL FROM ALL PROPOSEDBUILDING AND PAVEMENT AREAS PRIOR TO SITE GRADING. (THE TOPSOIL MAY BE STOCKPILED FOR LATER USE INLANDSCAPED AREAS.)

    3. THE CONTRACTOR SHALL REMOVE ALL ORGANIC MATERIAL AND OTHER DELETERIOUS MATERIALS PRIOR TO PLACINGGRADING FILL OR BASE COURSE. THE AREA SHOULD BE PROOF-ROLLED TO IDENTIFY ANY SOFT AREAS. WHERE SOFTAREAS ARE ENCOUNTERED, THE CONTRACTOR SHALL REMOVE THE SOIL AND REPLACE WITH COMPACTED FILL.

    4. ALL DEBRIS PILES AND BERMS SHOULD BE REMOVED AND HAULED AWAY FROM SITE OR USED AS GENERAL FILL INLANDSCAPED AREAS.

    5. THE CONTRACTOR SHALL CONSTRUCT THE BUILDING PAD TO THESE DESIGN PLANS AS PART OF THE SITE GRADINGCONTRACT, AND STRICTLY ADHERE TO THE SITE PREPARATION AND GRADING REQUIREMENTS OUTLINED IN THEGEOTECHNICAL REPORT.

    6. THE CONTRACTOR SHALL GRADE THE PROJECT SITE TO PROVIDE A SMOOTH TRANSITION BETWEEN NEW AND EXISTINGASPHALT, CURB AND GUTTER, AND ADJOINING SITE IMPROVEMENTS.

    7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE AND DEBRIS ON ADJACENT STREETS WHEN EQUIPMENT ISTRAVELING THOSE STREETS.

    8. THE CONTRACTOR SHALL BE FAMILIAR WITH ALL CONDITIONS AND RECOMMENDATIONS OUTLINED IN THE GEOTECHNICALREPORT AND TAKE ALL NECESSARY PRECAUTIONS AND RECOMMENDED PROCEDURES TO ASSURE SOUND GRADINGPRACTICES.

    9. THE CONTRACTOR SHALL TAKE APPROPRIATE GRADING MEASURES TO DIRECT STORM SURFACE RUNOFF TOWARDS CATCHBASINS.

    10. THE LOCATIONS OF UNDERGROUND FACILITIES SHOWN ON THESE PLANS ARE BASED ON ON-SITE SURVEY. IT SHALL BETHE CONTRACTORS' FULL RESPONSIBILITY TO CONTACT THE VARIOUS UTILITY COMPANIES TO LOCATE THEIR FACILITIESPRIOR TO PROCEEDING WITH CONSTRUCTION. NO ADDITIONAL COMPENSATION SHALL BE PAID TO THE CONTRACTOR FORDAMAGE AND REPAIR TO THESE FACILITIES CAUSED BY HIS WORK FORCE.

    11. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PERFORM ALL NECESSARY CUTS AND FILLS WITHIN THE LIMITSOF THIS PROJECT AND THE RELATED OFF-SITE WORK, SO AS TO GENERATE THE DESIRED SUBGRADE, FINISH GRADES, ANDSLOPES SHOWN.

    12. THE CONTRACTOR IS WARNED THAT AN EARTHWORK BALANCE WAS NOT NECESSARILY THE INTENT OF THIS PROJECT. ANYADDITIONAL MATERIAL REQUIRED OR LEFTOVER MATERIAL FOLLOWING EARTHWORK OPERATIONS BECOMES THERESPONSIBILITY OF THE CONTRACTOR.

    13. THE GRADING CONTRACTOR IS RESPONSIBLE TO COORDINATE WITH THE OWNER TO PROVIDE FOR THE REQUIREMENTS OFTHE PROJECT STORM WATER POLLUTION PREVENTION PLAN (SWPPP) AND ASSOCIATED PERMIT. ALL CONTRACTORACTIVITIES 1 ACRE OR MORE IN SIZE ARE REQUIRED TO PROVIDE A STORM WATER POLLUTION PREVENTION PLAN.

    14. ALL CUT AND FILL SLOPES SHALL BE PROTECTED UNTIL EFFECTIVE EROSION CONTROL HAS BEEN ESTABLISHED.

    15. THE USE OF POTABLE WATER WITHOUT A SPECIAL PERMIT FOR BUILDING OR CONSTRUCTION PURPOSES INCLUDINGCONSOLIDATION OF BACKFILL OR DUST CONTROL IS PROHIBITED. THE CONTRACTOR SHALL OBTAIN ALL NECESSARYPERMITS FOR CONSTRUCTION WATER FROM GOVERNING AGENCY.

    16. THE CONTRACTOR SHALL MAINTAIN THE STREETS, SIDEWALKS, AND ALL OTHER PUBLIC RIGHT-OF-WAYS IN A CLEAN, SAFEAND USABLE CONDITION. ALL SPILLS OF SOIL, ROCK OR CONSTRUCTION DEBRIS SHALL BE PROMPTLY REMOVED FROM THEPUBLICLY-OWNED PROPERTY DURING CONSTRUCTION AND UPON COMPLETION OF THE PROJECT. ALL ADJACENTPROPERTY, PRIVATE OR PUBLIC, SHALL BE MAINTAINED IN A CLEAN, SAFE, AND USABLE CONDITION.

    UTILITY NOTES1. ALL CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH THESE CONTRACT DOCUMENTS, CITY AND STATE

    REQUIREMENTS AND THE MOST RECENT EDITIONS OF THE FOLLOWING: THE INTERNATIONAL PLUMBING CODE, UTAHDRINKING WATER REGULATIONS, APWA MANUAL OF STANDARD PLANS AND SPECIFICATIONS. THE CONTRACTOR ISREQUIRED TO ADHERE TO ALL OF THE ABOVE-MENTIONED DOCUMENTS UNLESS OTHERWISE NOTED AND APPROVED BY THEENGINEER.

    2. CONTRACTOR SHALL COORDINATE LOCATION OF NEW "DRY UTILITIES" WITH THE APPROPRIATE UTILITY COMPANY,INCLUDING BUT NOT LIMITED TO: TELEPHONE & INTERNET SERVICE, GAS SERVICE, CABLE, AND POWER.

    3. EXISTING UTILITIES HAVE BEEN SHOWN ON THE PLANS BASED ON ON-SITE SURVEY. PRIOR TO COMMENCING ANY WORK, ITSHALL BE THE CONTRACTOR'S RESPONSIBILITY TO HAVE EACH UTILITY COMPANY LOCATE, IN THE FIELD, THEIR MAIN ANDSERVICE LINES. THE CONTRACTOR SHALL NOTIFY BLUE STAKES AT 1-800-662-4111 48 HOURS IN ADVANCE OF PERFORMINGANY EXCAVATION WORK. THE CONTRACTOR SHALL RECORD THE BLUE STAKES ORDER NUMBER AND FURNISH ORDERNUMBER TO OWNER AND ENGINEER PRIOR TO ANY EXCAVATION. IT WILL BE THE CONTRACTOR'S SOLE RESPONSIBILITY TODIRECTLY CONTACT ANY OTHER UTILITY COMPANIES THAT ARE NOT MEMBERS OF BLUE STAKES. IT SHALL BE THECONTRACTOR'S SOLE RESPONSIBILITY TO PROTECT ALL EXISTING UTILITIES SO THAT NO DAMAGE RESULTS TO THEMDURING THE PERFORMANCE OF THIS CONTRACT. ANY REPAIRS NECESSARY TO DAMAGED UTILITIES SHALL BE PAID FOR BYTHE CONTRACTOR. THE CONTRACTOR SHALL BE REQUIRED TO COOPERATE WITH OTHER CONTRACTORS AND UTILITYCOMPANIES INSTALLING NEW STRUCTURES, UTILITIES AND SERVICE TO THE PROJECT.

    4. CARE SHOULD BE TAKEN IN ALL EXCAVATIONS DUE TO POSSIBLE EXISTENCE OF UNRECORDED UTILITY LINES. EXCAVATIONREQUIRED WITHIN PROXIMITY OF EXISTING UTILITY LINES SHALL BE DONE BY HAND. CONTRACTOR SHALL REPAIR ANYDAMAGE TO EXISTING UTILITY LINES OR STRUCTURES INCURRED DURING CONSTRUCTION OPERATIONS AT CONTRACTOR'SEXPENSE.

    5. TRENCH BACKFILL MATERIAL AND COMPACTION TESTS ARE TO BE TAKEN PER APWA STANDARD SPECIFICATIONS (CURRENTEDITION), SECTION 02320 - BACKFILLING TRENCHES, OR AS REQUIRED BY THE GEOTECHNICAL REPORT IF NATIVE MATERIALSARE USED. NO NATIVE MATERIALS ARE ALLOWED IN THE PIPE ZONE. THE MAXIMUM LIFT FOR BACKFILLING EXCAVATIONS ISDETERMINED BY THE GEOTECHNICAL RECOMMENDATIONS.

    6. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR CONFORMING TO LOCAL AND FEDERAL CODES GOVERNING SHORING ANDBRACING OF EXCAVATIONS AND TRENCHES AND FOR THE PROTECTION OF WORKERS.

    7. THE CONTRACTOR IS REQUIRED TO KEEP ALL CONSTRUCTION ACTIVITIES WITHIN THE APPROVED PROJECT LIMITS. THISINCLUDES, BUT IS NOT LIMITED TO VEHICLE AND EQUIPMENT STAGING, MATERIAL STORAGE AND LIMITS OF TRENCHEXCAVATION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN PERMISSION AND/OR EASEMENTS FROM THEAPPROPRIATE GOVERNING ENTITY AND/OR INDIVIDUAL PROPERTY OWNER(S) FOR WORK OR STAGING OUTSIDE OF THEPROJECT LIMITS.

    8. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE, CAUSED BY ANY CONDITION INCLUDING SETTLEMENT, TOEXISTING UTILITIES FROM WORK PERFORMED AT OR NEAR EXISTING UTILITIES. THE CONTRACTOR SHALL TAKE ALLMEASURES NECESSARY TO PROTECT ALL EXISTING PUBLIC AND PRIVATE ROADWAY AND UTILITY FACILITIES. DAMAGE TOEXISTING FACILITIES CAUSED BY THE CONTRACTOR MUST BE REPAIRED BY THE CONTRACTOR AT HIS/HER EXPENSE TO THESATISFACTION OF THE OWNER OF SAID FACILITIES.

    9. ALL WATER LINE AND SEWER LINE INSTALLATION AND TESTING TO BE IN ACCORDANCE WITH LOCAL GOVERNING AGENCY'SSTANDARDS AND SPECIFICATIONS.

    10. ALL MANHOLES, HYDRANTS, VALVES, CLEANOUT BOXES, CATCH BASINS, METERS, ETC. MUST BE RAISED OR LOWERED TOFINAL GRADE PER APWA (CURRENT EDITION) STANDARDS AND INSPECTOR REQUIREMENTS. CONCRETE COLLARS MUST BECONSTRUCTED ON ALL MANHOLES, CLEANOUT BOXES, CATCH BASINS, AND VALVES PER APWA STANDARDS. ALL MANHOLE,CATCH BASIN, OR CLEANOUT BOX CONNECTIONS MUST BE MADE WITH THE PIPE CUT FLUSH WITH THE INSIDE OF THE BOXAND GROUTED OR SEALED.

    11. CONTRACTOR SHALL NOT ALLOW ANY GROUNDWATER OR DEBRIS TO ENTER THE NEW OR EXISTING PIPE DURINGCONSTRUCTION.

    12. SILT AND DEBRIS ARE TO BE CLEANED OUT OF ALL STORM DRAIN BOXES. CATCH BASINS ARE TO BE MAINTAINED IN ACLEANED CONDITION AS NEEDED UNTIL AFTER THE FINAL BOND RELEASE INSPECTION.

    13. CONTRACTOR SHALL CLEAN ASPHALT, TAR OR OTHER ADHESIVES OFF OF ALL MANHOLE LIDS AND INLET GRATES TO ALLOWACCESS.

    14. EACH TRENCH SHALL BE EXCAVATED SO THAT THE PIPE CAN BE LAID TO THE ALIGNMENT AND GRADE AS REQUIRED. THETRENCH WALL SHALL BE SO BRACED THAT THE WORKMEN MAY WORK SAFELY AND EFFICIENTLY. ALL TRENCHES SHALL BEDRAINED SO THE PIPE LAYING MAY TAKE PLACE IN DEWATERED CONDITIONS.

    15. CONTRACTOR SHALL PROVIDE AND MAINTAIN AT ALL TIMES AMPLE MEANS AND DEVICES WITH WHICH TO REMOVEPROMPTLY AND TO PROPERLY DISPOSE OF ALL WATER ENTERING THE TRENCH EXCAVATION.

    16. ALL SEWER LINES AND SEWER SERVICES SHALL HAVE A MINIMUM SEPARATION OF 10 FEET, EDGE TO EDGE, FROM THEWATER LINES. IF A 10 FOOT SEPARATION CAN NOT BE MAINTAINED, CONSTRUCT PER GOVERNING AGENCY'S MINIMUMSEPARATION STANDARDS.

    17. CONTRACTOR SHALL INSTALL THRUST BLOCKING AT ALL WATERLINE ANGLE POINTS AND TEES.

    18. ALL UNDERGROUND UTILITIES SHALL BE IN PLACE PRIOR TO INSTALLATION OF CURB, GUTTER, SIDEWALK AND STREETPAVING.

    19. CONTRACTOR SHALL INSTALL MAGNETIC LOCATING TAPE CONTINUOUSLY OVER ALL NONMETALLIC PIPE.

    GENERAL NOTES

    DEMOLITION NOTES

    APWA AMERICAN PUBLIC WORKS ASSOCIATIONAR ACCESSIBLE ROUTEASTM AMERICAN SOCIETY FOR TESTING AND MATERIALSAWWA AMERICAN WATER WORKS ASSOCIATIONBOS BOTTOM OF STEPBVC BEGIN VERTICAL CURVEC CURVECB CATCH BASINCF CURB FACE OR CUBIC FEETCL CENTER LINECO CLEAN OUTCOMM COMMUNICATIONCONC CONCRETECONT CONTINUOUSDIA DIAMETERDIP DUCTILE IRON PIPEELEC ELECTRICALELEV ELEVATIONEOA EDGE OF ASPHALT EVC END OF VERTICAL CURVEEW EACH WAYEXIST EXISTINGFF FINISH FLOORFG FINISH GRADEFH FIRE HYDRANTFL FLOW LINE OR FLANGEGB GRADE BREAKGF GARAGE FLOORGV GATE VALVEHC HANDICAPHP HIGH POINTIRR IRRIGATIONK RATE OF VERTICAL CURVATURELD LAND DRAINLF LINEAR FEETLP LOW POINTMEX MATCH EXISTINGMH MANHOLEMJ MECHANICAL JOINTNG NATURAL GROUNDNIC NOT IN CONTRACTNO NUMBEROC ON CENTEROCEW ON CENTER EACH WAYOHP OVERHEAD POWERPC POINT OF CURVATURE OR PRESSURE CLASSPCC POINT OF COMPOUND CURVATUREPI POINT OF INTERSECTIONPIV POST INDICATOR VALVEPL PROPERTY LINEPRC POINT OF REVERSE CURVATUREPRO PROPOSEDPT POINT OF TANGENCYPVC POINT OF VERTICAL CURVATUREPVI POINT OF VERTICAL INTERSECTIONPVT POINT OF VERTICAL TANGENCYR RADIUSRD ROOF DRAINROW RIGHT OF WAYS SLOPESAN SWR SANITARY SEWERSD STORM DRAINSEC SECONDARYSS SANITARY SEWERSTA STATIONSW SECONDARY WATER LINETBC TOP BACK OF CURBTOG TOP OF GRATETOA TOP OF ASPHALTTOC TOP OF CONCRETETOF TOP OF FOUNDATIONTOW TOP OF WALLTOS TOP OF STEPTYP TYPICALVC VERTICAL CURVEWIV WALL INDICATOR VALVEW WATER LINE

    CO

    CO

    GV

    E

    TR

    G

    IRR

    W

    T

    E

    SECTION CORNER

    EXISTING MONUMENT

    PROPOSED MONUMENT

    EXISTING REBAR AND CAP

    SET ENSIGN REBAR AND CAP

    EXISTING WATER METER

    PROPOSED WATER METER

    EXISTING WATER MANHOLE

    PROPOSED WATER MANHOLE

    EXISTING WATER BOX

    EXISTING WATER VALVE

    PROPOSED WATER VALVE

    EXISTING FIRE HYDRANT

    PROPOSED FIRE HYDRANT

    PROPOSED FIRE DEPARTMENT CONNECTION

    EXISTING SECONDARY WATER VALVE

    PROPOSED SECONDARY WATER VALVE

    EXISTING IRRIGATION BOX

    EXISTING IRRIGATION VALVE

    PROPOSED IRRIGATION VALVE

    EXISTING SANITARY SEWER MANHOLE

    PROPOSED SANITARY SEWER MANHOLE

    EXISTING SANITARY CLEAN OUT

    EXISTING STORM DRAIN CLEAN OUT BOX

    PROPOSED STORM DRAIN CLEAN OUT BOX

    EXISTING STORM DRAIN INLET BOX

    EXISTING STORM DRAIN CATCH BASIN

    PROPOSED STORM DRAIN CATCH BASIN

    EXISTING STORM DRAIN COMBO BOX

    PROPOSED STORM DRAIN COMBO BOX

    EXISTING STORM DRAIN CLEAN OUT

    EXISTING STORM DRAIN CULVERT

    PROPOSED STORM DRAIN CULVERT

    TEMPORARY SAG INLET PROTECTION

    TEMPORARY IN-LINE INLET PROTECTION

    ROOF DRAIN

    EXISTING ELECTRICAL MANHOLE

    EXISTING ELECTRICAL BOX

    EXISTING TRANSFORMER

    EXISTING UTILITY POLE

    EXISTING LIGHT

    PROPOSED LIGHT

    EXISTING GAS METER

    EXISTING GAS MANHOLE

    EXISTING GAS VALVE

    EXISTING TELEPHONE MANHOLE

    EXISTING TELEPHONE BOX

    EXISTING TRAFFIC SIGNAL BOX

    EXISTING CABLE BOX

    EXISTING BOLLARD

    PROPOSED BOLLARD

    EXISTING SIGN

    PROPOSED SIGN

    EXISTING SPOT ELEVATION

    PROPOSED SPOT ELEVATION

    EXISTING FLOW DIRECTION

    EXISTING TREE

    DENSE VEGETATION

    EXISTING EDGE OF ASPHALT

    PROPOSED EDGE OF ASPHALT

    EXISTING STRIPING

    PROPOSED STRIPING

    EXISTING FENCE

    PROPOSED FENCE

    EXISTING FLOW LINE

    PROPOSED FLOW LINE

    GRADE BREAK

    EXISTING STORM DRAIN LINE

    PROPOSED STORM DRAIN LINE

    ROOF DRAIN LINE

    CATCHMENTS

    HIGHWATER LINE

    EXISTING SANITARY SEWER

    PROPOSED SANITARY SEWER LINE

    PROPOSED SAN. SWR. SERVICE LINE

    EXISTING LAND DRAIN LINE

    PROPOSED LAND DRAIN LINE

    PROPOSED LAND DRAIN SERVICE LINE

    EXISTING CULINARY WATER LINE

    PROPOSED CULINARY WATER LINE

    PROPOSED CULINARY WATER SERVICE LINE

    EXISTING SECONDARY WATER LINE

    PROPOSED SECONDARY WATER LINE

    PROPOSED SEC. WATER SERVICE LINE

    EXISTING IRRIGATION LINE

    PROPOSED IRRIGATION LINE

    EXISTING OVERHEAD POWER LINE

    EXISTING ELECTRICAL LINE

    EXISTING GAS LINE

    EXISTING TELEPHONE LINE

    ACCESSIBLE ROUTE

    SAW CUT LINE

    STRAW WATTLE

    TEMPORARY BERM

    TEMPORARY SILT FENCE

    LIMITS OF DISTURBANCE

    EXISTING WALL

    PROPOSED WALL

    EXISTING CONTOURS

    PROPOSED CONTOURS

    BUILDABLE AREA WITHIN SETBACKS

    PUBLIC DRAINAGE EASEMENT

    EXISTING ASPHALT TO BE REMOVED

    PROPOSED ASPHALT

    EXISTING CURB AND GUTTER

    PROPOSED CURB AND GUTTER

    PROPOSED REVERSE PAN CURB AND GUTTER

    TRANSITION TO REVERSE PAN CURB

    CONCRETE TO BE REMOVED

    EXISTING CONCRETE

    PROPOSED CONCRETE

    BUILDING TO BE REMOVED

    EXISTING BUILDING

    PROPOSED BUILDING

    WV

    S

    D

    x

    X

    IRR

    swv

    WM

    WM

    W

    H Y D

    H Y DD

    D

    D

    S

    IRR

    swv

    WV

    W

    sd

    SD

    XXXX.XXTBC

    XXXX.XXTBC

    ss

    sw

    SS

    SW

    W

    IRR

    irr

    w

    SS

    W W

    SW

    ld

    LD

    LOD

    SF

    LEGEND

    TRAFFIC

    e

    g

    t

    HWL

    FR

    CABLE

    ohp

    LD

    NOTE: MAY CONTAIN SYMBOLS THAT ARE NOT USED IN THIS PLAN SET.

    RD

    D

    AR

    C001

    CIVIL GENERAL NOTES05/18/2020

    2019.073.00

    UNIVERSITY OF UTAH

    U OF U BLDG 73

    OWNER PROJECT NO.:

    GSBS PROJECT NO.:

    ISSUED DATE:

    REVISIONS:

    332 SOUTH 1400 EASTSALT LAKE CITY, UT 84112

    1795 EAST SOUTH CAMPUS DRIVE RM 201SALT LAKE CITY, UT 84115

    GSBSARCHITECTS

    375 WEST 200 SOUTHSALT LAKE CITY, UT 84101

    801.521.8600801.521.7913

    PF

    www.gsbsarchitects.com

    CONSTRUCTIONDOCUMENTS

    REV

    CALL BLUESTAKES@ 811 AT LEAST 48 HOURSPRIOR TO THECOMMENCEMENT OF ANYCONSTRUCTION.Know what's

    below.before you dig.Call

    R

    BENCHMARKNORTHWEST QUARTER OF SECTION 4,TOWNSHIP 1 SOUTH, RANGE 1 EASTSALT LAKE BASE AND MERIDIAN

    ELEV = 4615.86'

    SALT LAKE CITY

    45 W. 10000 S., Suite 500Sandy, UT 84070Phone: 801.255.0529

    LAYTON

    Phone: 801.547.1100

    TOOELE

    Phone: 435.843.3590CEDAR CITY

    Phone: 435.865.1453RICHFIELD

    Phone: 435.896.2983

    WWW.ENSIGNENG.COM

    E N S I G N

    THE STANDARD IN ENGINEERING

    No.4994371

    Brandon J. Page

    IL

    TTA E FO

    S

    EDENCS

    FPOR

    ISE S

    E

    ATU

    H

    RNE

    NI EG

    ALNO

  • 1. ALL WORK TO COMPLY WITH THE GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS.

    2. EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS ARE SHOWN IN THEIR APPROXIMATE LOCATIONSBASED UPON RECORD INFORMATION AVAILABLE AT THE TIME OF PREPARATION OF THESE PLANS. LOCATIONSMAY NOT HAVE BEEN VERIFIED IN THE FIELD AND NO GUARANTEE IS MADE AS TO THE ACCURACY ORCOMPLETENESS OF THE INFORMATION SHOWN. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TODETERMINE THE EXISTENCE AND LOCATION OF THE UTILITIES SHOWN ON THESE PLANS OR INDICATED IN THEFIELD BY LOCATING SERVICES. ANY ADDITIONAL COSTS INCURRED AS A RESULT OF THE CONTRACTOR'SFAILURE TO VERIFY THE LOCATIONS OF EXISTING UTILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION INTHEIR VICINITY SHALL BE BORNE BY THE CONTRACTOR AND ASSUMED INCLUDED IN THE CONTRACT. THECONTRACTOR IS TO VERIFY ALL CONNECTION POINTS WITH THE EXISTING UTILITIES. THE CONTRACTOR ISRESPONSIBLE FOR ANY DAMAGE CAUSED TO THE EXISTING UTILITIES AND UTILITY STRUCTURES THAT ARE TOREMAIN. IF CONFLICTS WITH EXISTING UTILITIES OCCUR, THE CONTRACTOR SHALL NOTIFY THE ENGINEERPRIOR TO CONSTRUCTION TO DETERMINE IF ANY FIELD ADJUSTMENTS SHOULD BE MADE.

    3. ALL SURFACE IMPROVEMENTS DISTURBED BY CONSTRUCTION SHALL BE RESTORED OR REPLACED,INCLUDING TREES AND DECORATIVE SHRUBS, SOD, FENCES, WALLS AND STRUCTURES, WHETHER OR NOTTHEY ARE SPECIFICALLY SHOWN ON THE CONTRACT DOCUMENTS.

    4. ALL CONSTRUCTION SIGNAGE, BARRICADES, TRAFFIC CONTROL DEVICES, ETC. SHALL CONFORM TO THELATEST EDITION OF THE M.U.T.C.D. THE CONTRACTOR WILL MAINTAIN SUCH SO THAT THEY ARE PROPERLYPLACED AND VISIBLE AT ALL TIMES.

    5. SIDEWALKS AND CURBS DESIGNATED TO BE DEMOLISHED SHALL BE DEMOLISHED TO THE NEARESTEXPANSION JOINT, MATCHING THESE PLANS AS CLOSELY AS POSSIBLE.

    6. THE CONTRACTOR IS TO PROTECT AND PRESERVE ALL EXISTING IMPROVEMENTS, UTILITIES, AND SIGNS, ETC.UNLESS OTHERWISE NOTED ON THESE PLANS.

    GENERAL NOTES

    1

    2

    3

    4

    5

    7

    SAWCUT, REMOVE, AND PROPERLY DISPOSE OF EXISTING CONCRETE SIDEWALK, STAIRWAY, AND MOWCURB.

    REMOVE AND PROPERLY DISPOSE OF EXISTING STORM DRAIN CATCH BASIN.

    REMOVE AND PROPERLY DISPOSE OF EXISTING STORM DRAIN PIPE.

    REMOVE AND PROPERLY DISPOSE OF EXISTING WALL.

    REMOVE EXISTING LANDSCAPING IN THIS AREA. SEE ARCHITECTURAL PLANS FOR ADDITIONALINFORMATION.

    REMOVE EXISTING IRRIGATION LINE. SEE SHEET C400 FOR FURTHER INFORMATION ON IRRIGATION LINEREROUTE.

    LIMIT OF DISTURBANCE.

    PROTECT AND PRESERVE ALL EXISTING IMPROVEMENTS, UTILITIES, SIGNS, ETC. (TYPICAL UNLESSOTHERWISE NOTED).

    EXISTING GAS LINE ASSUMED TO BE INACTIVE. COORDINATE WITH OWNER ABOUT FUTURE NEED OFEXISTING LINE.

    EXISTING IRRIGATION BOX. SEE ARCHITECTURAL/LANDSCAPE PLANS FOR FURTHER INFORMATION.

    BID ALTERNATE. SEE ARCHITECTURAL PLANS FOR FURTHER INFORMATION.

    6

    8

    9

    10

    11

    SCOPE OF WORK:PROVIDE, INSTALL AND/OR CONSTRUCT THE FOLLOWING PER THE SPECIFICATIONS GIVEN OR REFERENCED, THEDETAILS NOTED, AND/OR AS SHOWN ON THE CONSTRUCTION DRAWINGS:

    SDSDSD SD SD SD

    WWWWWWWWW

    WWWWW

    WW

    WW

    WW

    W

    EXIS

    TING

    BUIL

    DING

    EXIS

    TING

    BUIL

    DING

    EEE

    E

    EEEEEEEEEEEEEEEEE

    EE

    EE

    EE

    EE

    E

    E

    E

    E

    E

    EE

    E

    E

    EEEE

    EE

    E

    E

    E

    E

    EEEEEEEEEEEEEEEEE

    EEEE

    GG

    GG

    GG

    G

    EEEEEEEEEEEEE

    W

    W

    W

    W

    W

    W

    W

    W

    W

    W

    WWWWWWWWW

    WW

    WW

    WWWWWWWWW

    WW

    WW

    W

    W

    IRR IRR IRRIRR IRR

    irrirr

    irrirr

    IRR

    IRR

    IRR

    IRR

    IRR

    IRR

    IRR

    IRR

    IRR

    IRR

    IRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRR

    IRR IRR IRR

    IRR

    IRR

    IRR

    IRR

    T

    T

    T

    T

    T

    T

    T

    SDSDSDSD

    SDSD

    SD

    SDSD

    SDSD

    sdsd

    sdsd

    sdsd

    SDSD

    SD

    SD

    SD

    SD

    SD SD SD SD SD SD SD SD SD SD SD SD SD SD

    sdsd

    sd

    sd

    sd

    sdsd

    IRRIRR

    IRRIRR

    IRR

    CO

    WV

    WV

    IRR

    WV

    CO

    IRR

    E

    11

    1

    1

    3

    2

    4

    4

    5

    5

    5

    5

    555

    5

    8

    8

    8WALL

    LOD LODLOD LOD

    LOD

    LOD

    LOD

    LOD

    LOD LOD

    LOD

    LOD LOD LOD LOD

    LODLOD

    LODLODLODLOD

    LODLOD

    LODLOD

    LODLOD

    LODLOD

    LOD LOD LOD

    LOD

    LOD LOD LOD LOD LOD LOD

    LODLOD

    LOD

    LODLODLODLODLODLODLODLODLODLODLOD

    LODLODLO

    D

    LOD

    LOD

    LOD

    LOD

    LOD

    LOD

    LOD

    LOD

    LOD

    7

    7

    7

    8

    LIGHT POLE

    LIGHT POLE

    TREE

    8

    BEGIN

    5

    5

    8TREE

    6

    4

    4

    6

    6END

    118

    HANDRAIL &SIDEWALK

    8

    ELECTRICALBOX

    TREE

    8 SIDEWALK

    88RETAINING WALL

    3BEGIN

    3

    3END

    8MOWCURB

    8MOWCURB

    8MOWCURB

    8 SIDEWALK

    8SIDEWALK

    8SIDEWALK

    9

    10

    10

    17

    7

    1

    8

    8

    8

    8

    8 8

    88

    8

    8

    111

    8

    888

    C100

    DEMOLITION PLAN05/18/2020

    2019.073.00

    UNIVERSITY OF UTAH

    U OF U BLDG 73

    OWNER PROJECT NO.:

    GSBS PROJECT NO.:

    ISSUED DATE:

    REVISIONS:

    332 SOUTH 1400 EASTSALT LAKE CITY, UT 84112

    1795 EAST SOUTH CAMPUS DRIVE RM 201SALT LAKE CITY, UT 84115

    GSBSARCHITECTS

    375 WEST 200 SOUTHSALT LAKE CITY, UT 84101

    801.521.8600801.521.7913

    PF

    www.gsbsarchitects.com

    CONSTRUCTIONDOCUMENTS

    REV

    CALL BLUESTAKES@ 811 AT LEAST 48 HOURSPRIOR TO THECOMMENCEMENT OF ANYCONSTRUCTION.Know what's below.before you dig.Call

    R

    BENCHMARKNORTHWEST QUARTER OF SECTION 4,TOWNSHIP 1 SOUTH, RANGE 1 EASTSALT LAKE BASE AND MERIDIAN

    ELEV = 4615.86'

    SALT LAKE CITY

    45 W. 10000 S., Suite 500Sandy, UT 84070Phone: 801.255.0529

    LAYTON

    Phone: 801.547.1100

    TOOELE

    Phone: 435.843.3590CEDAR CITY

    Phone: 435.865.1453RICHFIELD

    Phone: 435.896.2983

    WWW.ENSIGNENG.COM

    E N S I G N

    THE STANDARD IN ENGINEERING

    No.4994371

    Brandon J. Page

    IL

    TTA E FO

    SED

    ENCS

    FPOR

    ISE S

    E

    ATU

    H

    RNE

    NI EG

    ALNO

    HORIZONTAL GRAPHIC SCALE0

    ( IN FEET )HORZ: 1 inch = ft.10

    10 5 10 20

  • 1. ALL WORK TO COMPLY WITH THE GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS.

    2. ALL IMPROVEMENTS MUST COMPLY WITH ADA STANDARDS AND RECOMMENDATIONS.

    3. SEE LANDSCAPE/ARCHITECTURAL PLANS FOR CONCRETE MATERIAL, COLOR, FINISH, AND SCORE PATTERNSTHROUGHOUT SITE.

    4. ALL PAVEMENT MARKINGS SHALL CONFORM TO THE LATEST EDITION OF THE M.U.T.C.D. (MANUAL ON UNIFORMTRAFFIC CONTROL DEVICES).

    5. ALL SURFACE IMPROVEMENTS DISTURBED BY CONSTRUCTION SHALL BE RESTORED OR REPLACED,INCLUDING TREES AND DECORATIVE SHRUBS, SOD, FENCES, WALLS AND STRUCTURES, WHETHER OR NOTTHEY ARE SPECIFICALLY SHOWN ON THE CONTRACT DOCUMENTS.

    6. NOTIFY ENGINEER OF ANY DISCREPANCIES IN DESIGN OR STAKING BEFORE PLACING CONCRETE OR ASPHALT.

    7. THE CONTRACTOR IS TO PROTECT AND PRESERVE ALL EXISTING IMPROVEMENTS, UTILITIES, AND SIGNS, ETC.UNLESS OTHERWISE NOTED ON THESE PLANS.

    GENERAL NOTES

    1

    2

    3

    4

    5

    6

    4” THICK CONCRETE SIDEWALK PER APWA STANDARD PLAN NO. 231.

    STAIRS IN SIDEWALK. SEE GRADING PLAN FOR ELEVATION INFORMATION. SEE ARCHITECTURAL PLANS FORHANDRAIL INFORMATION.

    PEDESTRIAN RAMP: 6" THICK CONCRETE WITH 6" UNTREATED BASE COURSE WITH #4 EPOXY-COATED REBAR@ 24" O.C.E.W.. SEE GRADING AND DRAINAGE PLAN FOR ELEVATION INFORMATION.

    RETAINING WALL. REFER TO GRADING PLAN FOR ELEVATION INFORMATION. SEE RETAINING WALL DESIGNSHEETS S000 AND S100 FOR WALL SCHEDULE AND DETAILS.

    LANDSCAPE/ARCHITECTURAL ELEMENT. SEE ARCHITECTURAL SITE PLAN SHEETS FOR DESIGN.

    BID ALTERNATE. SEE ARCHITECTURAL PLANS FOR FURTHER INFORMATION.

    SCOPE OF WORK:PROVIDE, INSTALL AND/OR CONSTRUCT THE FOLLOWING PER THE SPECIFICATIONS GIVEN OR REFERENCED, THEDETAILS NOTED, AND/OR AS SHOWN ON THE CONSTRUCTION DRAWINGS:

    EXIS

    TING

    BUIL

    DING

    EXIS

    TING

    BUIL

    DING

    T

    T

    T

    T

    T

    T

    T

    LOD LODLOD LOD

    LOD

    LOD

    LOD

    LOD

    LOD LOD

    LOD

    LOD LOD LOD LOD

    LODLOD

    LODLODLODLOD

    LODLOD

    LODLOD

    LODLOD

    LODLOD

    LOD LOD LOD

    LOD

    LOD LOD LOD LOD LOD LOD

    LODLOD

    LOD

    LODLODLODLODLODLODLODLODLODLODLOD

    LODLODLO

    D

    LOD

    LOD

    LOD

    LOD

    LOD

    LOD

    LOD

    LOD

    LOD

    1

    1

    1

    43 3

    3

    4

    4

    5

    5

    5

    1

    1

    4

    2

    2

    1

    5

    1

    1

    5

    11

    1

    5

    1

    5

    3

    56

    6

    4

    C200

    SITE PLAN05/18/2020

    2019.073.00

    UNIVERSITY OF UTAH

    U OF U BLDG 73

    OWNER PROJECT NO.:

    GSBS PROJECT NO.:

    ISSUED DATE:

    REVISIONS:

    332 SOUTH 1400 EASTSALT LAKE CITY, UT 84112

    1795 EAST SOUTH CAMPUS DRIVE RM 201SALT LAKE CITY, UT 84115

    GSBSARCHITECTS

    375 WEST 200 SOUTHSALT LAKE CITY, UT 84101

    801.521.8600801.521.7913

    PF

    www.gsbsarchitects.com

    CONSTRUCTIONDOCUMENTS

    REV

    CALL BLUESTAKES@ 811 AT LEAST 48 HOURSPRIOR TO THECOMMENCEMENT OF ANYCONSTRUCTION.Know what's below.before you dig.Call

    R

    BENCHMARKNORTHWEST QUARTER OF SECTION 4,TOWNSHIP 1 SOUTH, RANGE 1 EASTSALT LAKE BASE AND MERIDIAN

    ELEV = 4615.86'

    SALT LAKE CITY

    45 W. 10000 S., Suite 500Sandy, UT 84070Phone: 801.255.0529

    LAYTON

    Phone: 801.547.1100

    TOOELE

    Phone: 435.843.3590CEDAR CITY

    Phone: 435.865.1453RICHFIELD

    Phone: 435.896.2983

    WWW.ENSIGNENG.COM

    E N S I G N

    THE STANDARD IN ENGINEERING

    No.4994371

    Brandon J. Page

    IL

    TTA E FO

    SED

    ENCS

    FPOR

    ISE S

    E

    ATU

    H

    RNE

    NI EG

    ALNO

    HORIZONTAL GRAPHIC SCALE0

    ( IN FEET )HORZ: 1 inch = ft.10

    10 5 10 20

  • SDSDSD SD SD SD

    EXIS

    TING

    BUIL

    DING

    EXIS

    TING

    BUIL

    DING

    T

    T

    T

    T

    T

    T

    T

    SDSDSDSD

    SDSD

    SD

    SDSD

    SDSD

    SDSD

    SD

    SD

    SD

    SD

    SD SD SD SD SD SD SD SD SD SD SD SD SD SD

    LOD LODLOD LOD

    LOD

    LOD

    LOD

    LOD

    LOD LOD

    LOD

    LOD LOD LOD LOD

    LODLOD

    LODLODLODLOD

    LODLOD

    LODLOD

    LODLOD

    LODLOD

    LOD LOD LOD

    LOD

    LOD LOD LOD LOD LOD LOD

    LODLOD

    LOD

    LODLODLODLODLODLODLODLODLODLODLOD

    LODLODLO

    D

    LOD

    LOD

    LOD

    LOD

    LOD

    LOD

    LOD

    LOD

    LOD

    4620

    4625

    4630

    46214

    622

    4623

    4624

    4626

    4627

    4628

    4629

    4625 4622

    4623

    4624

    4626

    4627

    SDSD

    SDSD

    SD

    SD

    INSTALL 12"X12" YD #101TOG=4620.00FL(OUT-NW)=4618.50

    INSTALL 12"X12" YD #103TOG=4622.08

    FL(IN-E)=4619.10FL(OUT-W)=4619.10

    FL(IN-SE)=4619.10

    INSTALL 12"X12" YD #100TOG=4627.64

    FL(IN-E)=4624.54FL(OUT-W)=4620.15

    EXIST. SDCB SQR #EX1RIM=4631.42

    FL(OUT-W)=4627.37

    INSTALL 6" SDR-35 PVC-SD74.20 L.F. @ 1.41% SLOPE

    INSTALL 6" SDR-35 PVC-SD23.90 L.F. @ 1.00% SLOPE

    4627

    4623

    4622

    4622

    8.0%

    8.0%

    1.8%

    7.9% 1.8% 8.0%

    4.7%

    2.4%

    2.6%

    1

    1

    2

    2

    2

    3

    3

    2.7%

    EXISTING STORM DRAIN APPEARS TODAYLIGHT TO EXISTING CURB FACE #EX2

    2.6%

    0.6% 1

    .8%

    1.5%

    4.5%

    4625

    4621

    46224623

    4624

    TOC32.

    50

    20.26

    TOC

    TOC31.60

    TOC26.11

    TOC28.04

    TOC28.13

    TOC30.02TOC

    29.99TOC

    30.20

    31.43TOC

    TOS30.02

    TOC30.00

    TOC29.88

    TOC27.99

    TOC27.89

    TOC26.01

    TOC26.00

    TOC26.10

    TOC23.96

    TOC24.05

    TOC23.87

    TOC23.96

    21.88TOC

    TOC21.

    91

    20.03

    TOC

    TOC21.28

    TOC21.37

    TOC19.33

    TOC19.26

    TOC19.87

    21.89TOC

    21.70TOCTOC19.87

    TOC21.67

    TOC21.59 BOS

    21.60

    TOC21.20

    TOC21.50

    TOC30.52

    TOC30.31

    TOC30.10

    TOC30.02

    TOC26.15

    TOC20.10

    TOC19.99

    TOC19.99

    TOC32.

    38

    33.34TOCTOC32.62

    TOC32.93

    33.34TOCTOC

    32.91

    TOC32.86

    TOC32.84

    TOC32.93

    TOC32.56

    TOS32.93

    BOS26.11

    TOC30.34

    18.44TOC18.34TOC

    TOC18.64

    TOC18.85

    TOC18.70

    19.81

    TOC

    19.77

    TOC

    TOC21.70

    TOC21.84

    TOC21.80

    TOC21.84

    TOC21.87

    TOC21.71

    TOC21.68

    TOC21.64

    TOC21.49

    TOC21.47

    TOC21.86 TOC

    21.58

    TOW30.61

    TOW30.61

    TOW30.61

    TOW33.43

    TOW33.43

    TOW26.58

    TOW29.45

    TOW29.45

    TOW30.50

    TOW22.08

    BOW22.70

    BOW22.90

    BOW26.33

    TOW22.08

    TOW30.52

    INSTALL 2'X2' SDCBW/ SUMP #102TOG=4620.18FL(IN-SE)=4618.26FL(OUT-NW)=4619.16

    4

    INSTALL 6" SDR-35 PVC-SD12.25 L.F. @ 0.48% SLOPE

    1

    TOC18.49

    4625

    4630

    4621

    4622

    4623462

    4

    4626

    4627

    4628

    4629

    4631

    4621

    4619

    TOW23.29

    TOW24.79

    TOW26.29

    FG25.05

    FG-TOW26.29

    FG-TOW26.29

    FG-TOW24.79

    FG-TOC21.28

    TOW30.74

    FG28.56

    FG28.68

    TOW31.52

    TOW30.45

    TOC30.45

    4626462646274628

    FG-TOW26.29

    FG-TOW26.29

    FG-TOW24.79

    TOC32.97

    4.6%

    TOC20.10

    1. ALL WORK TO COMPLY WITH THE GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS.

    2. ALL IMPROVEMENTS MUST COMPLY WITH ADA STANDARDS AND RECOMMENDATIONS.

    3. ALL WORK SHALL COMPLY WITH THE RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEER POSSIBLYINCLUDING, BUT NOT LIMITED TO, REMOVAL OF UNCONSOLIDATED FILL, ORGANICS, AND DEBRIS, PLACEMENTOF SUBSURFACE DRAIN LINES AND GEOTEXTILE, AND OVEREXCAVATION OF UNSUITABLE BEARING MATERIALSAND PLACEMENT OF ACCEPTABLE FILL MATERIAL.

    4. THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE EXISTING SOIL CONDITIONS.

    5. ELEVATIONS HAVE BEEN TRUNCATED FOR CLARITY. XX.XX REPRESENTS AN ELEVATION OF 48XX.XX ONTHESE PLANS.

    6. LANDSCAPED AREAS REQUIRE SUBGRADE TO BE MAINTAINED AT A SPECIFIC ELEVATION BELOW FINISHEDGRADE AND REQUIRE SUBGRADE TO BE PROPERLY PREPARED AND SCARIFIED. SEE LANDSCAPE PLANS FORADDITIONAL INFORMATION.

    7. SLOPE ALL LANDSCAPED AREAS AWAY FROM BUILDING FOUNDATIONS TOWARD CURB AND GUTTER ORSTORM DRAIN INLETS.

    8. EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS ARE SHOWN IN THEIR APPROXIMATE LOCATIONSBASED UPON RECORD INFORMATION AVAILABLE AT THE TIME OF PREPARATION OF THESE PLANS. LOCATIONSMAY NOT HAVE BEEN VERIFIED IN THE FIELD AND NO GUARANTEE IS MADE AS TO THE ACCURACY ORCOMPLETENESS OF THE INFORMATION SHOWN. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TODETERMINE THE EXISTENCE AND LOCATION OF THE UTILITIES SHOWN ON THESE PLANS OR INDICATED IN THEFIELD BY LOCATING SERVICES. ANY ADDITIONAL COSTS INCURRED AS A RESULT OF THE CONTRACTOR'SFAILURE TO VERIFY THE LOCATIONS OF EXISTING UTILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION INTHEIR VICINITY SHALL BE BORNE BY THE CONTRACTOR AND ASSUMED INCLUDED IN THE CONTRACT. THECONTRACTOR IS TO VERIFY ALL CONNECTION POINTS WITH THE EXISTING UTILITIES. THE CONTRACTOR ISRESPONSIBLE FOR ANY DAMAGE CAUSED TO THE EXISTING UTILITIES AND UTILITY STRUCTURES THAT ARE TOREMAIN. IF CONFLICTS WITH EXISTING UTILITIES OCCUR, THE CONTRACTOR SHALL NOTIFY THE ENGINEERPRIOR TO CONSTRUCTION TO DETERMINE IF ANY FIELD ADJUSTMENTS SHOULD BE MADE.

    9. ALL STORM DRAIN INFRASTRUCTURE TO BE INSTALLED PER GOVERNING AGENCY OR APWA STANDARD PLANSAND SPECIFICATIONS.

    10. ENSURE MINIMUM COVER OVER ALL STORM DRAIN PIPES PER MANUFACTURER'S RECOMMENDATIONS.NOTIFY ENGINEER IF MINIMUM COVER CANNOT BE ATTAINED.

    11. ALL FACILITIES WITH DOWNSPOUTS/ROOF DRAINS SHALL BE CONNECTED TO THE STORM DRAIN SYSTEM. SEEPLUMBING PLANS FOR DOWNSPOUT/ROOF DRAIN LOCATIONS AND SIZES. ALL ROOF DRAINS TO HAVEMINIMUM 1% SLOPE.

    12. THE CONTRACTOR SHALL ADJUST TO GRADE ALL EXISTING UTILITIES AS NEEDED PER LOCAL GOVERNINGAGENCY'S STANDARDS AND SPECIFICATIONS.

    13. NOTIFY ENGINEER OF ANY DISCREPANCIES IN DESIGN OR STAKING BEFORE PLACING CONCRETE, ASPHALT,OR STORM DRAIN STRUCTURES OR PIPES.

    14. THE CONTRACTOR IS TO PROTECT AND PRESERVE ALL EXISTING IMPROVEMENTS, UTILITIES, AND SIGNS, ETC.UNLESS OTHERWISE NOTED ON THESE PLANS.

    GENERAL NOTES

    1

    3

    4

    ADS HP-STORM DRAIN PIPE OR APPROVED EQUAL. INSTALLATION AND BACKFILL PER GOVERNING AGENCY'SSTANDARDS. LENGTH AND SLOPE PER PLAN.

    YARD DRAIN (YD). PRECAST 2' X 2' BOX OR ADS NYLOPLAST DRAIN BASIN PER MANUFACTURERRECOMMENDATIONS WITH 12" SQ. OR ROUND PEDESTRIAN SAFE CAST IRON GRATE. CONTRACTOR TOPROVIDE SHOP DRAWING SUBMITTAL FOR ENGINEER'S APPROVAL.

    CONTRACTOR TO FIELD LOCATE EXACT DEPTH OF EXISTING STORM DRAIN PIPE. NOTIFY ENGINEER PRIORTO INSTALLATION.

    2'x2' SDCB WITH SUMP PER DETAIL 1/C600.

    SCOPE OF WORK:PROVIDE, INSTALL AND/OR CONSTRUCT THE FOLLOWING PER THE SPECIFICATIONS GIVEN OR REFERENCED, THEDETAILS NOTED, AND/OR AS SHOWN ON THE CONSTRUCTION DRAWINGS:

    2

    C300

    GRADING ANDDRAINAGE PLAN

    05/18/2020

    2019.073.00

    UNIVERSITY OF UTAH

    U OF U BLDG 73

    OWNER PROJECT NO.:

    GSBS PROJECT NO.:

    ISSUED DATE:

    REVISIONS:

    332 SOUTH 1400 EASTSALT LAKE CITY, UT 84112

    1795 EAST SOUTH CAMPUS DRIVE RM 201SALT LAKE CITY, UT 84115

    GSBSARCHITECTS

    375 WEST 200 SOUTHSALT LAKE CITY, UT 84101

    801.521.8600801.521.7913

    PF

    www.gsbsarchitects.com

    CONSTRUCTIONDOCUMENTS

    REV

    CALL BLUESTAKES@ 811 AT LEAST 48 HOURSPRIOR TO THECOMMENCEMENT OF ANYCONSTRUCTION.Know what's below.before you dig.Call

    R

    BENCHMARKNORTHWEST QUARTER OF SECTION 4,TOWNSHIP 1 SOUTH, RANGE 1 EASTSALT LAKE BASE AND MERIDIAN

    ELEV = 4615.86'

    SALT LAKE CITY

    45 W. 10000 S., Suite 500Sandy, UT 84070Phone: 801.255.0529

    LAYTON

    Phone: 801.547.1100

    TOOELE

    Phone: 435.843.3590CEDAR CITY

    Phone: 435.865.1453RICHFIELD

    Phone: 435.896.2983

    WWW.ENSIGNENG.COM

    E N S I G N

    THE STANDARD IN ENGINEERING

    No.4994371

    Brandon J. Page

    IL

    TTA E FO

    SED

    ENCS

    FPOR

    ISE S

    E

    ATU

    H

    RNE

    NI EG

    ALNO

    HORIZONTAL GRAPHIC SCALE0

    ( IN FEET )HORZ: 1 inch = ft.10

    10 5 10 20

  • 1. ALL WORK TO COMPLY WITH THE GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS.

    2. EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS ARE SHOWN IN THEIR APPROXIMATE LOCATIONSBASED UPON RECORD INFORMATION AVAILABLE AT THE TIME OF PREPARATION OF THESE PLANS. LOCATIONSMAY NOT HAVE BEEN VERIFIED IN THE FIELD AND NO GUARANTEE IS MADE AS TO THE ACCURACY ORCOMPLETENESS OF THE INFORMATION SHOWN. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TODETERMINE THE EXISTENCE AND LOCATION OF THE UTILITIES SHOWN ON THESE PLANS OR INDICATED IN THEFIELD BY LOCATING SERVICES. ANY ADDITIONAL COSTS INCURRED AS A RESULT OF THE CONTRACTOR'SFAILURE TO VERIFY THE LOCATIONS OF EXISTING UTILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION INTHEIR VICINITY SHALL BE BORNE BY THE CONTRACTOR AND ASSUMED INCLUDED IN THE CONTRACT. THECONTRACTOR IS TO VERIFY ALL CONNECTION POINTS WITH THE EXISTING UTILITIES. THE CONTRACTOR ISRESPONSIBLE FOR ANY DAMAGE CAUSED TO THE EXISTING UTILITIES AND UTILITY STRUCTURES THAT ARE TOREMAIN. IF CONFLICTS WITH EXISTING UTILITIES OCCUR, THE CONTRACTOR SHALL NOTIFY THE ENGINEERPRIOR TO CONSTRUCTION TO DETERMINE IF ANY FIELD ADJUSTMENTS SHOULD BE MADE.

    3. ALL SANITARY SEWER INFRASTRUCTURE TO BE INSTALLED PER GOVERNING AGENCY STANDARD PLANS ANDSPECIFICATIONS.

    4. ALL WATER INFRASTRUCTURE TO BE INSTALLED PER GOVERNING AGENCY OR APWA STANDARD PLANS ANDSPECIFICATIONS.

    6. DEFLECT OR LOOP ALL WATERLINES TO AVOID CONFLICTS WITH OTHER UTILITIES PER GOVERNING AGENCY'SSTANDARDS AND SPECIFICATIONS.

    7. PROJECT SHALL COMPLY WITH ALL UTAH DIVISION OF DRINKING WATER RULES AND REGULATIONS INCLUDING,BUT NOT LIMITED TO, THOSE PERTAINING TO BACKFLOW PROTECTION AND CROSS CONNECTION PREVENTION.

    8. THE CONTRACTOR IS TO COORDINATE ALL UTILITIES WITH MECHANICAL/PLUMBING PLANS.

    9. NOTIFY ENGINEER OF ANY DISCREPANCIES IN DESIGN OR STAKING BEFORE PLACING UTILITY STRUCTURESOR PIPES.

    10. THE CONTRACTOR SHALL ADJUST TO GRADE ALL EXISTING UTILITIES AS NEEDED PER LOCAL GOVERNINGAGENCY'S STANDARDS AND SPECIFICATIONS.

    11. THE CONTRACTOR IS TO PROTECT AND PRESERVE ALL EXISTING IMPROVEMENTS, UTILITIES, AND SIGNS, ETC.UNLESS OTHERWISE NOTED ON THESE PLANS.

    GENERAL NOTES

    1

    2

    REROUTE EXISTING IRRIGATION LINE PER GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS.

    90° BEND W/ THRUST BLOCK PER GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS.

    SCOPE OF WORK:PROVIDE, INSTALL AND/OR CONSTRUCT THE FOLLOWING PER THE SPECIFICATIONS GIVEN OR REFERENCED, THEDETAILS NOTED, AND/OR AS SHOWN ON THE CONSTRUCTION DRAWINGS:

    WWWWWWW

    WW

    W

    EXIS

    TING

    BUIL

    DING

    EXIS

    TING

    BUIL

    DING

    EE

    EEEEEEEEE

    EE

    EE

    E

    E

    EE

    EE

    E

    E

    E

    EEEEEEEEEEE

    GG

    G

    EEEEEE

    W

    W

    W

    W

    WWWW

    WW

    WWWW

    WW

    W

    IRR IRR

    IRR

    IRR

    IRR

    IRR

    IRR

    IRRIRRIRRIRRIRRIRRIRR

    IRRIR

    RIRR

    T

    T

    T

    T

    IRRIRR

    IRRIRR

    IRR

    CO

    WV

    WV

    IRR

    WV

    CO

    IRR

    E

    LOD LODLO

    DLO

    D

    LOD

    LOD LOD

    LOD

    LODLOD

    LODLOD

    LODLOD

    LOD LOD

    LOD LOD LOD

    LOD

    LODLODLODLODLODLOD

    LODLOD

    LOD

    LOD

    LOD

    LOD

    IRR

    IRR

    1

    1

    2

    2

    2

    2

    1

    C400

    UTILITY PLAN05/18/2020

    2019.073.00

    UNIVERSITY OF UTAH

    U OF U BLDG 73

    OWNER PROJECT NO.:

    GSBS PROJECT NO.:

    ISSUED DATE:

    REVISIONS:

    332 SOUTH 1400 EASTSALT LAKE CITY, UT 84112

    1795 EAST SOUTH CAMPUS DRIVE RM 201SALT LAKE CITY, UT 84115

    GSBSARCHITECTS

    375 WEST 200 SOUTHSALT LAKE CITY, UT 84101

    801.521.8600801.521.7913

    PF

    www.gsbsarchitects.com

    CONSTRUCTIONDOCUMENTS

    REV

    CALL BLUESTAKES@ 811 AT LEAST 48 HOURSPRIOR TO THECOMMENCEMENT OF ANYCONSTRUCTION.Know what's

    below.before you dig.Call

    R

    BENCHMARKNORTHWEST QUARTER OF SECTION 4,TOWNSHIP 1 SOUTH, RANGE 1 EASTSALT LAKE BASE AND MERIDIAN

    ELEV = 4615.86'

    SALT LAKE CITY

    45 W. 10000 S., Suite 500Sandy, UT 84070Phone: 801.255.0529

    LAYTON

    Phone: 801.547.1100

    TOOELE

    Phone: 435.843.3590CEDAR CITY

    Phone: 435.865.1453RICHFIELD

    Phone: 435.896.2983

    WWW.ENSIGNENG.COM

    E N S I G N

    THE STANDARD IN ENGINEERING

    No.4994371

    Brandon J. Page

    IL

    TTA E FO

    S

    EDENCS

    FPOR

    ISE S

    E

    ATU

    H

    RNE

    NI EG

    ALNO

    HORIZONTAL GRAPHIC SCALE0

    ( IN FEET )HORZ: 1 inch = ft.10

    10 5 10 20

  • 1. THIS PLAN IS DESIGNED AS A FIRST APPRAISAL OF NECESSARY MEANS TO PROTECT THE WATERS OF THESTATE FROM POTENTIAL POLLUTION. IT IS THE RESPONSIBILITY OF THE OWNER/OPERATOR TO ADDWARRANTED BEST MANAGEMENT PRACTICES (BMP'S) AS NECESSARY, MODIFY THOSE SHOWN ASAPPROPRIATE, AND DELETE FROM THE PROJECT THOSE FOUND TO BE UNNECESSARY. FEDERAL AND STATELAW ALLOWS THESE UPDATES TO BE MADE BY THE OWNER/OPERATOR ONSITE AND RECORDED BY THEOWNER/OPERATOR ON THE COPY OF THE SWPPP KEPT ONSITE.

    2. DISTURBED LAND SHALL BE KEPT TO A MINIMUM. STABILIZATION MEASURES SHALL BE INITIATED AS SOON ASPRACTICABLE IN PORTIONS OF THE SITE WHERE CONSTRUCTION ACTIVITIES HAVE TEMPORARILY ORPERMANENTLY CEASED, BUT IN NO CASE MORE THAN 14 DAYS AFTER THE CONSTRUCTION ACTIVITY IN THATPORTION OF THE SITE HAS TEMPORARILY OR PERMANENTLY CEASED. HOWEVER, WHERE CONSTRUCTIONACTIVITY ON A PORTION OF THE SITE IS TEMPORARILY CEASED, AND EARTH DISTURBING ACTIVITIES WILL BERESUMED WITHIN 21 DAYS, TEMPORARY STABILIZATION MEASURES DO NOT HAVE TO BE INITIATED ON THATPORTION OF THE SITE.

    3. RESEED DISTURBED LAND WITH NATIVE GRASS MIXTURE WITHIN 14 CALENDAR DAYS OF ACHIEVEMENT OFFINISH GRADE TO STABILIZE SOILS IF LAND IS NOT TO BE RE-WORKED WITHIN 14 CALENDAR DAYS OF THECESSATION OF CONSTRUCTION ACTIVITIES AT THAT LOCATION.

    4. DETAILS SHOWN ARE TO BE EMPLOYED TO PROTECT RUNOFF AS APPROPRIATE DURING CONSTRUCTION.NOT ALL DETAILS ARE NECESSARY AT ALL PHASES OF THE PROJECT. IT SHALL BE THE RESPONSIBILITY OFTHE OWNER/OPERATOR TO USE APPROPRIATE BEST MANAGEMENT PRACTICES AT THE APPROPRIATE PHASEOF CONSTRUCTION. SEE SWPPP FOR BMP IMPLEMENTATION SCHEDULE.

    5. VARIOUS BEST MANAGEMENT PRACTICES HAVE BEEN SHOWN ON THE PLANS AT SUGGESTED LOCATIONS.THE CONTRACTOR MAY MOVE AND RECONFIGURE THESE BMP'S TO OTHER LOCATIONS IF PREFERRED,PROVIDED THE INTENT OF THE DESIGN IS PRESERVED.

    6. NOT ALL POSSIBLE BMP'S HAVE BEEN SHOWN. THE CONTRACTOR IS RESPONSIBLE TO APPLY CORRECTMEASURES TO PREVENT THE POLLUTION OF STORM WATER PER PROJECT SWPPP.

    7. A UPDES (UTAH POLLUTANT DISCHARGE ELIMINATION SYSTEM) PERMIT IS REQUIRED FOR ALL CONSTRUCTIONACTIVITIES 1 ACRE OR MORE.

    GENERAL NOTES

    1

    2

    3

    4

    5

    6

    INLET PROTECTION PER DETAIL 2/C600.

    SILT FENCE PER DETAIL 3/C600.

    PORTABLE TOILET PER DETAIL 4/C600.

    VEHICLE WASHDOWN AND STABILIZED CONSTRUCTION ENTRANCE PER DETAIL 5/C600.

    SUGGESTED TEMPORARY CONSTRUCTION SITE PARKING, STAGING, DUMPSTER, AND MATERIAL STORAGEAREA.

    SUGGESTED STOCKPILE AREA.

    SCOPE OF WORK:PROVIDE, INSTALL AND/OR CONSTRUCT THE FOLLOWING PER THE SPECIFICATIONS GIVEN OR REFERENCED, THEDETAILS NOTED, AND/OR AS SHOWN ON THE CONSTRUCTION DRAWINGS:

    SDSDSD SD SD SD

    EXIS

    TING

    BUIL

    DING

    EXIS

    TING

    BUIL

    DING

    GG

    GG

    GG

    G

    T

    T

    T

    T

    T

    T

    T

    SDSDSDSD

    SDSD

    SD

    SD

    SD

    SD

    SD SD SD SD SD SD SD SD SD SD SD SD SD SD

    CO

    CO

    LOD LODLOD LOD

    LOD

    LOD

    LOD

    LOD

    LOD LOD

    LOD

    LOD LOD LOD LOD

    LODLOD

    LODLODLODLOD

    LODLOD

    LODLOD

    LODLOD

    LODLOD

    LOD LOD LOD

    LOD

    LOD LOD LOD LOD LOD LOD

    LODLOD

    LOD

    LODLODLODLODLODLODLODLODLODLODLOD

    LODLODLO

    D

    LOD

    LOD

    LOD

    LOD

    LOD

    LOD

    LOD

    LOD

    LOD

    sdsd

    sdSD

    SDSD

    SDSD

    sdsd

    sdsd

    SD

    4625

    4625

    46304630

    4622

    4622

    4623

    4623

    4624

    4624

    4626

    46264627

    4627

    4628

    4628

    4629

    4629

    4631

    4630

    462746284629

    46314632

    SFSFSFSFSFSFSFSFSFSFSF

    SFSFSF

    SF

    SF

    SFSF

    SFSF

    SFSF

    SF

    1

    1

    1

    1

    2

    2

    2

    2

    3 5 6

    4

    1

    C500

    EROSION CONTROLPLAN

    05/18/2020

    2019.073.00

    UNIVERSITY OF UTAH

    U OF U BLDG 73

    OWNER PROJECT NO.:

    GSBS PROJECT NO.:

    ISSUED DATE:

    REVISIONS:

    332 SOUTH 1400 EASTSALT LAKE CITY, UT 84112

    1795 EAST SOUTH CAMPUS DRIVE RM 201SALT LAKE CITY, UT 84115

    GSBSARCHITECTS

    375 WEST 200 SOUTHSALT LAKE CITY, UT 84101

    801.521.8600801.521.7913

    PF

    www.gsbsarchitects.com

    CONSTRUCTIONDOCUMENTS

    REV

    CALL BLUESTAKES@ 811 AT LEAST 48 HOURSPRIOR TO THECOMMENCEMENT OF ANYCONSTRUCTION.Know what's

    below.before you dig.Call

    R

    BENCHMARKNORTHWEST QUARTER OF SECTION 4,TOWNSHIP 1 SOUTH, RANGE 1 EASTSALT LAKE BASE AND MERIDIAN

    ELEV = 4615.86'

    SALT LAKE CITY

    45 W. 10000 S., Suite 500Sandy, UT 84070Phone: 801.255.0529

    LAYTON

    Phone: 801.547.1100

    TOOELE

    Phone: 435.843.3590CEDAR CITY

    Phone: 435.865.1453RICHFIELD

    Phone: 435.896.2983

    WWW.ENSIGNENG.COM

    E N S I G N

    THE STANDARD IN ENGINEERING

    No.4994371

    Brandon J. Page

    IL

    TTA E FO

    SED

    ENCS

    FPOR

    ISE S

    E

    ATU

    H

    RNE

    NI EG

    ALNO

    HORIZONTAL GRAPHIC SCALE0

    ( IN FEET )HORZ: 1 inch = ft.10

    10 5 10 20

    REVISION SCHEDULE

    NUMBER DATE AUTHOR COMPANY REPRESENTATIVESIGNATURE

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

  • SCALE:7 NONEPORTABLE TOILET

    GRAVEL PAD

    FLOWSID

    EWALK

    FLOW

    SECURE AGAINST WIND

    CONTAINMENT EARTH BERM

    SCALE:8 NONESTABILIZED CONSTRUCTION ENTRANCE

    SWALE

    TO SE

    DIMEN

    TATION

    BASIN

    50.0' M

    IN.

    WASH DOWN PAD

    15.0' MIN.

    3"-6" ROCK, 9" THICK1/2"-3/4" FILTER LAYER

    FILTER FABRIC BELOW GRAVEL

    1. PLACE SIGN ADJACENT TO ENTRANCE " CONSTRUCTION TRAFFIC ONLY - ALLCONSTRUCTION TRAFFIC SHALL ENTER AND EXIT SITE AT THIS LOCATION"

    NOTE:

    SCALE:5 NONESAG INLET PROTECTION

    SILT FENCE REQUIREDBEHIND CURB AT BOX

    UNTIL LAND BEHINDCURB IS STABILIZED

    NOTES:

    1. PLACE WATTLES OR GRAVEL BAGS TIGHTAGAINST CURB TO PREVENT SEDIMENT-LADENWATER FROM GETTING BETWEEN CURB ANDWATTLE/BAG.

    2. PLACE WATTLES OR GRAVEL BAGS SUCH THATFLOW DOES NOT OVERTOP CURB OR ROADCENTERLINE.

    3. INSPECT INLET PROTECTION AFTER EVERYLARGE STORM EVENT AND AT LEAST BI-WEEKLY,OR PER SWPPP REQUIREMENTS, WHICHEVER ISMORE STRINGENT, TO ENSURE THAT SEDIMENTCONTROL IS MEETING ITS DESIGN INTENT.MAINTAIN AND/OR REPLACE AS NEEDED.

    4. REMOVE SEDIMENT ACCUMULATED WHEN ITREACHES 50% OF GRAVEL BAG OR WATTLEHEIGHT.

    5. CONTRACTOR MAY SUBMIT AN ALTERNATIVEMETHOD OF INLET PROTECTION. THEALTERNATIVE METHOD SHALL BE APPROVED BYTHE CITY INSPECTOR AND THE ENGINEER OFRECORD.

    6. BEFORE PLACEMENT OF CURB, STABILIZATIONOF LAND BEHIND CURB, AND/OR PAVING,MAINTAIN TOP OF INLET AT 6" ABOVE GRADE,AND SURROUND WITH SILT FENCE FORSEDIMENTATION AROUND BOX. MAINTAIN SILTFENCE BEHIND BOX UNTIL LAND BEHIND CURBIS STABILIZED.

    SANDBAG OPTION

    WATTLE OPTION

    FLOW

    FLOW

    FLOW

    FLOW

    SILT FENCE REQUIRED BEHINDCURB AT BOX UNTIL LAND

    BEHIND CURB IS STABILIZED

    EARTH SAVER SEDIMENTSAVER OR EQUAL, FILLED WITH1/2 CF 3/4" GRAVEL, ZIPPER SIDEFACING AWAY FROM INLET

    8" DIA. EARTH SAVERWEIGHTED WATTLEOR EQUAL

    FLOW

    FLOW

    FLOWFLOW

    FILTER FABRICWRAPPED

    COMPLETELYAROUND GATE

    SCALE:6 NONETEMPORARY SILT FENCE

    RUNOFF 1

    2 MAX

    RUNOFF DIRECTION

    2'-0"

    6"

    12" M

    IN.

    SIDEWALK IF ANY

    CURB ANDGUTTER IF ANY

    UNDISTURBEDGROUND

    WOODEN OR STEEL FENCEPOSTS @ 10.0' O.C. MAX. MIRAFI FILTER FABRIC

    GRANULAR BACKFILL,SEE NOTE 3

    APPROX. 6"x6"TRENCH

    EMBED FABRICBELOW BACKFILL

    1. EXCAVATE 6"x6" TRENCH ALONGLIMITS OF DISTURBANCE AS SHOWNON CONSTRUCTION DRAWINGS.

    2. POSTS SHALL BE POSITIONED ONDOWNSTREAM SIDE OF FENCE.

    3. LAY TOE-IN FABRIC FLAP IN BOTTOMOF TRENCH. BACKFILL TRENCH WITHFREE DRAINING GRANULARMATERIAL. COMPACT TRENCH TOSATISFACTION OF THE ENGINEER OFRECORD.

    4. SILT FENCE GEOTEXTILE SHALLMEET AASHTO M288-92REQUIREMENTS.

    5. REMOVE & DISPOSE OF SEDIMENTWHEN ACCUMULATION IS 50% OFEXPOSED FENCE HEIGHT.

    6. 10' MAX. SPACING BETWEEN STAKES.7. SILT FENCES SHALL BE INSTALLED

    ALONG CONTOURS, NOT UP ANDDOWN SLOPES, WITH 10' OVERLAPAT BREAKS.

    NOTES:

    SCALE:1 NONE2x2 SDCB WITH SUMP

    3'-6"

    DRAI

    N RO

    CK

    1'-0"

    BACK

    FILL

    2'-0 1

    /4"TH

    IS P

    ORTI

    ON T

    O BE

    PERF

    ORAT

    ED W

    ITH

    1 1/2"

    DIA.

    HOL

    ES 12

    " O.C

    .

    2'-0"1'-0"

    15" GRATE PRECAST PERFORATED 2'x2' YARDDRAIN WITH GRATE

    WRAP IN MIRAFI 140N GEOTEXTILE FABRIC,OVERLAPPING FABRIC BY 2 FEET

    NOMINAL 3/4" - 2" CLEAN, CRUSHED, ANGULAR STONE(AASHTO M43 #3 THROUGH #57 STONE SIZES ALLOWED)

    1'-0"

    SD PIPEPER PLAN

    SD PIPEPER PLAN

    C600

    CIVIL DETAILS05/18/2020

    2019.073.00

    UNIVERSITY OF UTAH

    U OF U BLDG 73

    OWNER PROJECT NO.:

    GSBS PROJECT NO.:

    ISSUED DATE:

    REVISIONS:

    332 SOUTH 1400 EASTSALT LAKE CITY, UT 84112

    1795 EAST SOUTH CAMPUS DRIVE RM 201SALT LAKE CITY, UT 84115

    GSBSARCHITECTS

    375 WEST 200 SOUTHSALT LAKE CITY, UT 84101

    801.521.8600801.521.7913

    PF

    www.gsbsarchitects.com

    CONSTRUCTIONDOCUMENTS

    REV

    CALL BLUESTAKES@ 811 AT LEAST 48 HOURSPRIOR TO THECOMMENCEMENT OF ANYCONSTRUCTION.Know what's below.before you dig.Call

    R

    BENCHMARKNORTHWEST QUARTER OF SECTION 4,TOWNSHIP 1 SOUTH, RANGE 1 EASTSALT LAKE BASE AND MERIDIAN

    ELEV = 4615.86'

    SALT LAKE CITY

    45 W. 10000 S., Suite 500Sandy, UT 84070Phone: 801.255.0529

    LAYTON

    Phone: 801.547.1100

    TOOELE

    Phone: 435.843.3590CEDAR CITY

    Phone: 435.865.1453RICHFIELD

    Phone: 435.896.2983

    WWW.ENSIGNENG.COM

    E N S I G N

    THE STANDARD IN ENGINEERING

    No.4994371

    Brandon J. Page

    IL

    TTA E FO

    S

    EDENCS

    FP OR

    ISE S

    E

    ATU

    H

    RNE

    NI EG

    ALNO

  • DESIGN CRITERIA

    1. GOVERNING BUILDING CODE: 2018 IBC

    2. SEISMIC LOADING:A. SS = 1.357gB. S1 = 0.503gC. SDS = 1.086gD. SD1 = 0.603gE. SEISMIC DESIGN CATEGORY = DF. SITE CLASS = D (Default)

    3. WIND LOADING:A. BASIC WIND SPEED, V = 105 MPH - 3 SEC GUSTB. ASD WIND SPEED, VASD = 82 MPH - 3 SEC GUSTC. EXPOSURE = CD. WIND DIRECTIONALITY FACTOR, KD = 0.85F. WIND TOPTGRAPHIC FACTOR, KZT = 1.0

    GENERAL

    1. ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH THE GOVERNING BUILDING CODE AND SUPPLEMENTS UNLESS HIGHER STANDARD IS REQUIRED BY LOCAL BUILDING OFFICIAL.

    2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE.

    3. THE CONTRACTOR IS RESPONSIBLE FOR MEETING ALL APPLICABLE OSHA SAFETY REQUIREMENTS DURING CONSTRUCTION AND SHALL BE RESPONSIBLE FOR SAFETY AND PROTECTION WITHIN AND ADJACENT TO THE SITE.

    4. AT ANY GIVEN TIME DURING AND AFTER CONSTRUCTION, THE CONTRACTOR AND/OR OWNER SHALL ENSURE THE LOADS ON THE STRUCTURE DO NOT EXCEED THE SPECIFIED DESIGN LOADS. CONSTRUCTION MATERIAL SHALL BE SPREAD OUT IF PLACED ON FRAMED FLOORS OR ROOF.

    5. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE ENGINEER BEFORE CONTINUING WITH CONSTRUCTION.

    6. THE TYPICAL DETAILS SHALL BE USED WHEREVER APPLICABLE UNLESS OTHERWISE NOTED ON THE DRAWINGS. SPECIFIC NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS.

    7. ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE STRUCTURAL ENGINEER BEFORE PROCEEDING WITH ANY WORK INVOLVED. IN CASE OF CONFLICT, FOLLOW MOST STRINGENT REQUIREMENT AS DETERMINED BY STRUCTURAL ENGINEER WITHOUT COST TO OWNER.

    8. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES.

    9. WHERE REFERENCE IS MADE TO VARIOUS TEST STANDARDS FOR MATERIALS, SUCH STANDARDS SHALL BE THE LATEST EDITION AND/OR ADDENDUM.

    10. ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. DO NOT PENETRATE ANY STRUCTURAL ELEMENTS (BEAMS, COLUMNS, WALLS, SLABS, STEEL DECKS, ETC.) WITHOUT PRIOR WRITTEN APPROVAL OF STRUCTURAL ENGINEER THROUGH ARCHITECT.

    11. ANY ENGINEERING DESIGN PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW SHALL BEAR THE SEAL OF A CIVIL OR STRUCTURAL ENGINEER REGISTERED IN THE STATE IN WHICH THE PROJECT IS LOCATED.

    1. SHOP DRAWINGS SHALL BE SUBMITTED TO THE GENERAL CONTRACTOR PRIOR TO FABRICATION OR ERECTION FOR THE FOLLOWING ITEMS: A. REINFORCING STEEL B. CONCRETE MIX DESIGNS

    2. THE GENERAL CONTRACTOR SHALL SUBMIT ELECTRONIC COPIES OF ALL SHOP DRAWINGS TO THE STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION OR ERECTION. FIVE (5) WORKING DAYS (MINIMUM) SHALL BE ALLOWED FOR THE REVIEW OF THESE SHOP DRAWINGS BY THE STRUCTURAL ENGINEER.

    3. THE GENERAL CONTRACTOR WILL REVIEW AND STAMP ALL SHOP DRAWINGS AND PRODUCT DATA FOR CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS PRIOR TO SUBMISSION. ANY SHOP DRAWINGS OR PRODUCT DATA NOT REVIEWED AND STAMPED BY THE GENERAL CONTRACTOR WILL BE RETURNED WITHOUT REVIEW.

    4. ANY SHOP DRAWING NOT CHECKED AND INITIALED BY THE SUPPLIER/DETAILER PRIOR TO SUBMITTING FOR ARCHITECTURAL AND ENGINEERING REV